Konerman, Monica A; Price, Jennifer; Torres, Dawn; Li, Zhiping
2014-09-01
Large-volume paracentesis (LVP) can be time and labor intensive depending on the amount of ascites removed and the method of drainage. Wall suction has been adopted as the preferred method of drainage at many centers, though the safety and benefits of this technique have not been formally evaluated. The primary objective of this study was to define the cost and time savings of wall suction over the traditional glass vacuum bottle method for ascites drainage. The secondary objective was to compare the safety profile and patient satisfaction using these two techniques. We conducted a randomized, controlled pilot study of the wall suction versus vacuum bottle methods for LVP in hospitalized patients. All LVPs were performed under ultrasound guidance by a single proceduralist. Patients with at least 4 liters removed received 25% intravenous albumin, 8 g/liter fluid removed. Demographic, clinical characteristics, and procedure details were recorded. Laboratory and hemodynamic data were recorded for 24 h prior to and 24-48 h post LVP. An electronic chart review was conducted to evaluate procedure-related complications. Data were compared using Fisher's exact test, t test, or Mann-Whitney U test. Thirty-four patients were randomized to wall suction at 200 mmHg (n = 17) or glass vacuum bottle drainage (n = 17). Wall suction was significantly faster and less costly than vacuum bottle drainage (7 versus 15 min, p = 0.002; $4.59 versus $12.73, p < 0.001). There were no differences in outcomes at 24 and 48 h post LVP, or at 60-day follow up. Performing LVP using wall suction resulted in significantly shorter procedure time and supply cost savings. There were no differences in outcomes between the groups, suggesting equivalent safety, though larger studies powered to detect small differences are needed. Given its efficiency, convenience, and cost effectiveness, wall suction may be a superior method of ascites drainage for LVP.
Shinozaki, Satoshi; Miura, Yoshimasa; Ino, Yuji; Shinozaki, Kenjiro; Lefor, Alan Kawarai; Yamamoto, Hironori
2015-01-01
Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel. PMID:26668798
Phase dependencies of the human baroreceptor reflex
NASA Technical Reports Server (NTRS)
Seidel, H.; Herzel, H.; Eckberg, D. L.
1997-01-01
We studied the influence of respiratory and cardiac phase on responses of the cardiac pacemaker to brief (0.35-s) increases of carotid baroreceptor afferent traffic provoked by neck suction in seven healthy young adult subjects. Cardiac responses to neck suction were measured indirectly from electrocardiographic changes of heart period. Our results show that it is possible to separate the influences of respiratory and cardiac phases at the onset of a neck suction impulse by a product of two factors: one depending only on the respiratory phase and one depending only on the cardiac phase. This result is consistent with the hypothesis that efferent vagal activity is a function of afferent baroreceptor activity, whereas respiratory neurons modulate that medullary throughput independent of the cardiac phase. Furthermore, we have shown that stimulus broadening and stimulus cropping influence the outcome of neck suction experiments in a way that makes it virtually impossible to obtain information on the phase dependency of the cardiac pacemaker's sensitivity to vagal stimulation without accurate knowledge of the functional shape of stimulus broadening.
Effect of suction-dependent soil deformability on landslide susceptibility maps
NASA Astrophysics Data System (ADS)
Lizarraga, Jose J.; Buscarnera, Giuseppe; Frattini, Paolo; Crosta, Giovanni B.
2016-04-01
This contribution presents a physically-based, spatially-distributed model for shallow landslides promoted by rainfall infiltration. The model features a set of Factor of Safety values aimed to capture different failure mechanisms, namely frictional slips with limited mobility and flowslide events associated with the liquefaction of the considered soils. Indices of failure associated with these two modes of instability have been derived from unsaturated soil stability principles. In particular, the propensity to wetting-induced collapse of unsaturated soils is quantified through the introduction of a rigid-plastic model with suction-dependent yielding and strength properties. The model is combined with an analytical approach (TRIGRS) to track the spatio-temporal evolution of soil suction in slopes subjected to transient infiltration. The model has been tested to reply the triggering of shallow landslides in pyroclastic deposits in Sarno (1998, Campania Region, Southern Italy). It is shown that suction-dependent mechanical properties, such as soil deformability, have important effects on the predicted landslide susceptibility scenarios, resulting on computed unstable zones that may encompass a wide range of slope inclinations, saturation levels, and depths. Such preliminary results suggest that the proposed methodology offers an alternative mechanistic interpretation to the variability in behavior of rainfall-induced landslides. Differently to standard methods the explanation to this variability is based on suction-dependent soil behavior characteristics.
Vortical and acoustical mode coupling inside a porous tube with uniform wall suction.
Jankowskia, T A; Majdalani, J
2005-06-01
This paper considers the oscillatory motion of gases inside a long porous tube of the closed-open type. In particular, the focus is placed on describing an analytical solution for the internal acoustico-vortical coupling that arises in the presence of appreciable wall suction. This unsteady field is driven by longitudinal oscillatory waves that are triggered by small unavoidable fluctuations in the wall suction speed. Under the assumption of small amplitude oscillations, the time-dependent governing equations are linearized through a regular perturbation of the dependent variables. Further application of the Helmholtz vector decomposition theorem enables us to discriminate between acoustical and vortical equations. After solving the wave equation for the acoustical contribution, the boundary-driven vortical field is considered. The method of matched-asymptotic expansions is then used to obtain a closed-form solution for the unsteady momentum equation developing from flow decomposition. An exact series expansion is also derived and shown to coincide with the numerical solution for the problem. The numerically verified end results suggest that the asymptotic scheme is capable of providing a sufficiently accurate solution. This is due to the error associated with the matched-asymptotic expansion being smaller than the error introduced in the Navier-Stokes linearization. A basis for comparison is established by examining the evolution of the oscillatory field in both space and time. The corresponding boundary-layer behavior is also characterized over a range of oscillation frequencies and wall suction velocities. In general, the current solution is found to exhibit features that are consistent with the laminar theory of periodic flows. By comparison to the Sexl profile in nonporous tubes, the critically damped solution obtained here exhibits a slightly smaller overshoot and depth of penetration. These features may be attributed to the suction effect that tends to attract the shear layers closer the wall.
Optimal concentrations in nectar feeding
Kim, Wonjung; Gilet, Tristan; Bush, John W. M.
2011-01-01
Nectar drinkers must feed quickly and efficiently due to the threat of predation. While the sweetest nectar offers the greatest energetic rewards, the sharp increase of viscosity with sugar concentration makes it the most difficult to transport. We here demonstrate that the sugar concentration that optimizes energy transport depends exclusively on the drinking technique employed. We identify three nectar drinking techniques: active suction, capillary suction, and viscous dipping. For each, we deduce the dependence of the volume intake rate on the nectar viscosity and thus infer an optimal sugar concentration consistent with laboratory measurements. Our results provide the first rationale for why suction feeders typically pollinate flowers with lower sugar concentration nectar than their counterparts that use viscous dipping. PMID:21949358
Green, Timothy R.; Freyberg, David L.
1995-01-01
Anisotropy in large-scale unsaturated hydraulic conductivity of layered soils changes with the moisture state. Here, state-dependent anisotropy is computed under conditions of large-scale gravity drainage. Soils represented by Gardner's exponential function are perfectly stratified, periodic, and inclined. Analytical integration of Darcy’s law across each layer results in a system of nonlinear equations that is solved iteratively for capillary suction at layer interfaces and for the Darcy flux normal to layering. Computed fluxes and suction profiles are used to determine both upscaled hydraulic conductivity in the principal directions and the corresponding “state-dependent” anisotropy ratio as functions of the mean suction. Three groups of layered soils are analyzed and compared with independent predictions from the stochastic results of Yeh et al. (1985b). The small-perturbation approach predicts appropriate behaviors for anisotropy under nonarid conditions. However, the stochastic results are limited to moderate values of mean suction; this limitation is linked to a Taylor series approximation in terms of a group of statistical and geometric parameters. Two alternative forms of the Taylor series provide upper and lower bounds for the state-dependent anisotropy of relatively dry soils.
Effects of snout dimensions on the hydrodynamics of suction feeding in juvenile and adult seahorses.
Roos, Gert; Van Wassenbergh, Sam; Aerts, Peter; Herrel, Anthony; Adriaens, Dominique
2011-01-21
Seahorses give birth to juveniles having a fully functional feeding apparatus, and juvenile feeding behaviour shows striking similarities to that of adults. However, a significant allometric growth of the snout is observed during which the snout shape changes from relatively short and broad in juveniles to relatively long and slender in adults. Since the shape of the buccal cavity is a critical determinant of the suction performance, this snout allometry will inevitably affect the suction feeding ability. To test whether the snout is optimised for suction feeding throughout an ontogeny, we simulated the expansion of different snout shapes varying from extremely long and slender to short and broad for juvenile and adult snout sizes, using computational fluid dynamic models. Our results showed that the snout diameter at the start of the simulations is involved in a trade-off between the realizable suction volume and expansion time on the one hand (improving with larger initial diameters), and maximal flow velocity on the other hand (improving with smaller initial diameters). Moreover suction performance (suction volume as well as maximal attainable flow velocity) increased with decreasing snout length. However, an increase in snout length decreases the time to reach the prey by the cranial rotation, which may explain the prevalence of long snouts among syngnathid fishes despite the reduced suction performance. Thus, the design of the seahorse snout revolves around a trade-off between the ability to generate high-volume suction versus minimisation of the time needed to reach the prey by the cranial rotation. Copyright © 2010 Elsevier Ltd. All rights reserved.
Karolyi, Florian; Morawetz, Linde; Colville, Jonathan F; Handschuh, Stephan; Metscher, Brian D; Krenn, Harald W
2013-11-01
A well-developed suction pump in the head represents an important adaptation for nectar-feeding insects, such as Hymenoptera, Lepidoptera and Diptera. This pumping organ creates a pressure gradient along the proboscis, which is responsible for nectar uptake. The extremely elongated proboscis of the genus Prosoeca (Nemestrinidae) evolved as an adaptation to feeding from long, tubular flowers. According to the functional constraint hypothesis, nectar uptake through a disproportionately elongated, straw-like proboscis increases flower handling time and consequently lowers the energy intake rate. Due to the conspicuous length variation of the proboscis of Prosoeca, individuals with longer proboscides are hypothesised to have longer handling times. To test this hypothesis, we used field video analyses of flower-visiting behaviour, detailed examinations of the suction pump morphology and correlations of proboscis length with body length and suction pump dimensions. Using a biomechanical framework described for nectar-feeding Lepidoptera in relation to proboscis length and suction pump musculature, we describe and contrast the system in long-proboscid flies. Flies with longer proboscides spent significantly more time drinking from flowers. In addition, proboscis length and body length showed a positive allometric relationship. Furthermore, adaptations of the suction pump included an allometric relationship between proboscis length and suction pump muscle volume and a combination of two pumping organs. Overall, the study gives detailed insight into the adaptations required for long-proboscid nectar feeding, and comparisons with other nectar-sucking insects allow further considerations of the evolution of the suction pump in insects with sucking mouthparts.
NASA Astrophysics Data System (ADS)
Karolyi, Florian; Morawetz, Linde; Colville, Jonathan F.; Handschuh, Stephan; Metscher, Brian D.; Krenn, Harald W.
2013-11-01
A well-developed suction pump in the head represents an important adaptation for nectar-feeding insects, such as Hymenoptera, Lepidoptera and Diptera. This pumping organ creates a pressure gradient along the proboscis, which is responsible for nectar uptake. The extremely elongated proboscis of the genus Prosoeca (Nemestrinidae) evolved as an adaptation to feeding from long, tubular flowers. According to the functional constraint hypothesis, nectar uptake through a disproportionately elongated, straw-like proboscis increases flower handling time and consequently lowers the energy intake rate. Due to the conspicuous length variation of the proboscis of Prosoeca, individuals with longer proboscides are hypothesised to have longer handling times. To test this hypothesis, we used field video analyses of flower-visiting behaviour, detailed examinations of the suction pump morphology and correlations of proboscis length with body length and suction pump dimensions. Using a biomechanical framework described for nectar-feeding Lepidoptera in relation to proboscis length and suction pump musculature, we describe and contrast the system in long-proboscid flies. Flies with longer proboscides spent significantly more time drinking from flowers. In addition, proboscis length and body length showed a positive allometric relationship. Furthermore, adaptations of the suction pump included an allometric relationship between proboscis length and suction pump muscle volume and a combination of two pumping organs. Overall, the study gives detailed insight into the adaptations required for long-proboscid nectar feeding, and comparisons with other nectar-sucking insects allow further considerations of the evolution of the suction pump in insects with sucking mouthparts.
Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz
2014-07-01
Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P < 0.05). But these changes were not significant between the two groups (P > 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.
Tenny, Steven O; Thorell, William E
2018-05-05
Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.
An improved design method and experimental performance of two dimensional curved wall diffusers
NASA Technical Reports Server (NTRS)
Yang, T.; Hudson, W. G.; El-Nashar, A. M.
1972-01-01
A computer design program was developed to incorporate the suction slots in solving the potential flow equations with prescribed boundary conditions. Using the contour generated from this program two Griffith diffusers were tested having area ratios AR = 3 and 4. The inlet Reynolds number ranged from 600,000 to 7 million. It was found that the slot suction required for metastable operation depends on the sidewall suction applied. Values of slot suction of 8% of the inlet flow rate was required for AR = 4 with metastable condition, provided that enough sidewall suction was applied. For AR = 3, the values of slot suction was about 25% lower than those required for AR = 4. For nearly all unseparated test runs, the effectiveness was 100% and the exit flow was uniform. In addition to the Griffith diffusers, dump and cusp diffusers of comparable area ratios were built and tested. The results obtained from these diffusers were compared with those of the Griffith diffusers. Flow separation occurred in all test runs with the dump and cusp diffusers.
Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S
2016-02-01
To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P < .01) or in combination with strategic tenting (110 seconds; P < .01) significantly reduced this time. No significant benefit was seen when tenting was used alone (160 seconds; P < .30). Use of a vacuum suction device during surgery will lower local oxygen concentration, and this in turn may decrease the risk of operating room fires. Although strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.
[Extendable Cords to Prevent Tumbling of a Suction Device during Craniotomy].
Shimizu, Satoru; Mochizuki, Takahiro; Osawa, Shigeyuki; Sekiguchi, Tomoko; Koizumi, Hiroyuki; Kumabe, Toshihiro
2016-02-01
Suction is necessary during craniotomy, and intraoperative tumbling of the suction device interrupts operative procedures. To avoid this, we developed a technique that would fasten the device to an extendable cord as is used to secure cell phones. We used this technique in more than 300 craniotomies at the specific point of time when the suction device tends to tumble, i. e., during the opening and closure of a wound, which requires frequent instrument exchanges. Extendable cords fastened to the tip of the suction hose using a gift tie were attached to the drapes to secure the suction device next to the operative field. During the operation, the extendable cord followed the suction device manipulations. Consequently, although there was some tension in the cord during its extension, the maneuverability of the suction device was maintained. As the hanging suction device was closer to the operative field than devices stored in conventional pockets, its manipulation was easier and quicker. Upon release, the suction device automatically returned to its original position without distracting the surgeon. Tumbling of the device was prevented, and there were no procedure-related complications. Our simple modification using extendable cords prevented tumbling, avoided unnecessary replacements, and eased the manipulation of a suction device.
Jenkins, William S A; Hall, David P; Dhaliwal, Kev; Hill, Adam T; Hirani, Nik
2012-01-01
We present the case of a 68-year-old woman who presented in extremis with a secondary pneumothorax with a past history of severe idiopathic pulmonary fibrosis. Following insertion of a 32F intercostal drain, she developed a persistent broncho-pleural fistula and became dependent on negative-pressure wall-mounted suction to prevent respiratory compromise. She declined definitive surgical intervention and was therefore managed conservatively. After adhering to the wall-mounted suction method for 49 days, we obtained for use a portable digital thoracic drainage system previously used only in the cardiothoracic postoperative patient. This electronically delivered, negative-pressure drainage system induced radiographic improvement within 24 h, and allowed the patient to mobilise for the first time since admission. The patient was discharged home with the Thopaz drain in situ 8 weeks after placing it, and the drain was removed successfully with a resolved pneumothorax 20 weeks after her initial presentation. PMID:22684832
Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C
2015-10-01
Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces cannot be adequately disinfected without disassembly, which is costly in time, staff and resources. The automated STCS DCU suction disinfection system used with single component handpieces provides an effective solution. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Broadband electromagnetic analysis of compacted kaolin
NASA Astrophysics Data System (ADS)
Bore, Thierry; Wagner, Norman; Cai, Caifang; Scheuermann, Alexander
2017-01-01
The mechanical compaction of soil influences not only the mechanical strength and compressibility but also the hydraulic behavior in terms of hydraulic conductivity and soil suction. At the same time, electric and dielectric parameters are increasingly used to characterize soil and to relate them with mechanic and hydraulic parameters. In the presented study electromagnetic soil properties and suction were measured under defined conditions of standardized compaction tests. The impact of external mechanical stress conditions of nearly pure kaolinite was analyzed on soil suction and broadband electromagnetic soil properties. An experimental procedure was developed and validated to simultaneously determine mechanical, hydraulic and broadband (1 MHz-3 GHz) electromagnetic properties of the porous material. The frequency dependent electromagnetic properties were modeled with a classical mixture equation (advanced Lichtenecker and Rother model, ALRM) and a hydraulic-mechanical-electromagnetic coupling approach was introduced considering water saturation, soil structure (bulk density, porosity), soil suction (pore size distribution, water sorption) as well as electrical conductivity of the aqueous pore solution. Moreover, the relaxation behavior was analyzed with a generalized fractional relaxation model concerning a high-frequency water process and two interface processes extended with an apparent direct current conductivity contribution. The different modeling approaches provide a satisfactory agreement with experimental data for the real part. These results show the potential of broadband electromagnetic approaches for quantitative estimation of the hydraulic state of the soil during densification.
Bissen-Miyajima, Hiroko; Suzuki, Shintaro; Ohashi, Yoshie; Minami, Keiichiro
2005-03-01
To observe changes in intraocular pressure (IOP), the manner in which the eye is suctioned, and the effect of the number of suction ports. Department of Ophthalmology, Tokyo Dental College, Suidobashi Hospital, Tokyo, Japan. Suction rings with single or dual ports were made of transparent acrylic acid resin to facilitate observation with a digital video camera. The IOP and the duration of the IOP increase (time to reach 90% of the maximum IOP) were measured in 6 porcine eyes with an intra-vein pressure-sensor catheter in the vitreous cavity. The IOP changes were recorded using a personal computer. Suctioning with single- and dual-port suction rings was similar. The IOP increases with single- and dual-port suction rings were similar (99.1 mm Hg +/- 6.1 [SD] and 99.0 +/- 6.5 mm Hg, respectively) (P=.987). The duration of the IOP increase was also similar (4.21 +/- 0.24 seconds and 4.12 +/- 0.33 seconds, respectively) (P=.190). The number of ports did not affect suctioning and changes in IOP. This technique is useful in developing the ideal shape and setting of the suction ring.
Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.
Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus
2011-01-01
Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P < .001) from the preset level. Fluid aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P < .001) and was much more during 15 and 20 seconds suction time as compared to 5 seconds (P < .001). Massive aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.
Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne
2018-05-01
To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube suction. The ESAT© is the first validated tool to systematically guide endotracheal nursing practice for the "inexperienced" nurse. © 2018 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.
2017-08-01
The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.
Experiments on tandem diffusers with boundary-layer suction applied in between
NASA Technical Reports Server (NTRS)
Barna, P. S.
1979-01-01
Experiments were performed on conical diffusers of various configurations with the same, but rather unusually large, 16:1 area ratio. Because available performance data on diffusers fall short of very large area ratio configurations, an unconventional design, consisting of two diffusers following each other in tandem, was proposed. Both diffusers had the same area ratio of 4:1, but had different taper angles. While for the first diffuser (called leading) the angle remained constant, for the second (called follower), the taper angle was stepped up to higher values. Boundary layer control, by way of suction, was applied between the diffusers, and a single slot suction ring was inserted between them. The leading diffuser had an enclosed nominal divergence angle 2 theta = 5 degrees, while the follower diffusers had either 10, 20, 30, or 40 degrees, respectively, giving 4 combinations. The experiments were performed at four different Reynolds numbers with various suction rates. The rates indicate a general improvement in the performance of all diffusers with boundary layer suction. It appears that the improvement of the pressure recovery depends on both the Reynolds number and the suction rate, and the largest increase, 0.075, was found at the lowest R sub e when the follower divergence was 2 theta = 40 degrees.
Physics and function of operating room suction.
Meagher, A P; Hugh, T B; Li, B; Montano, S R
1991-09-01
A study was done to evaluate the performance of suction apparatus in the operating room. The investigation was prompted by perceived poor suction performance in a suite of new operating rooms built in accordance with Standards Australia (SA) specifications. SA performance tests were conducted on each of four suction outlets in nine operating rooms. All 36 outlets complied with SA standards for flow-rate (minimum 40 L/min) and occluded negative pressure (ONP; minimum -60 kPa). However, 24 collection units failed to comply with standards (ONP) of -40 kPa achieved in less than 4 s when a 4 L disposable suction apparatus was connected (mean time to ONP: 6.1 s, 95% confidence interval: 4.9, 7.3). When smaller capacity suction jars were substituted, more units met SA standards. The standards therefore need revision to include specification of the capacity of the collecting apparatus. Other factors that were found to degrade suction performance significantly were air leakage and defective shut-off valves. The physical principles involved in operating room suction are described. Surgeons and anaesthetists should understand these principles, and it is recommended that a simple pre-operative check of the suction apparatus should be carried out, as follows: (1) Turn the wall control knob fully on, and disconnect the suction apparatus. The gauge should register zero. (2) Connect the suction jars. If the indicated gauge pressure is in excess of -15 kPa, investigate the equipment for excessive resistance, particularly in the shut-off valve, which should be replaced with a new unit if necessary.(ABSTRACT TRUNCATED AT 250 WORDS)
Mercury vapour exposure during dental student training in amalgam removal
2013-01-01
Background Amalgam that is used for dental fillings contains approximately 50% elemental mercury. During dental student training, amalgam is often removed by drilling without the use of water spray and suction, which are protective measures in preventing mercury aerosol. In this study we measured mercury vapor levels in ambient air during amalgam removal as is typically performed in dental training. Methods Mercury vapor levels in ambient air were measured in a dental school laboratory during removal of amalgam fillings from artificial teeth set into a dental jaw simulator. Mercury vapor was measured under three conditions (25 measurements each): with the simultaneous use of water spray and suction, with the use of suction only, and with the use of neither suction nor water spray. These three conditions are all used during dental student training. Results were compared to Alberta occupational exposure limits for mercury vapor in order to assess potential occupational risk to students. Analysis of variance testing was used to compare data obtained under the three conditions. Results When water spray and suction were used, mercury vapor levels ranged from 4.0 to 19.0 μg/m3 (arithmetic mean = 8.0 μg/m3); when suction only was used, mercury vapor levels ranged from 14.0 to 999.0 (999.0 μg/m3 represents the high limit detection of the Jerome analyzer) (arithmetic mean = 141.0 μg/m3); when neither suction nor water was used, the vapor levels ranged from 34.0 to 796.0 μg/m3 (arithmetic mean = 214.0 μg/m3). Conclusions The Alberta Occupational Health and Safety threshold limit value for mercury vapor over an eight-hour time-weighted period is 25.0 μg/m3. The absolute ceiling for mercury vapor, not to be exceeded at any time, is 125.0 μg/m3. When both water spray and suction were used, mercury vapor levels were consistently below this threshold. When suction without water spray was used, mercury vapor levels exceeded the safety threshold 8% of the time. When neither water spray nor suction was used, 36% of the mercury vapor readings exceeded the absolute ceiling value. To maximize safety, dental schools should train students to remove amalgam only while using water spray and high volume suction. Alternatively, students should use appropriate occupational hygiene personal protective equipment during amalgam removals. PMID:24090056
ERIC Educational Resources Information Center
Wooley, John F.
Capillary suction time is time required for the liquid phase of a treated sludge to travel through 1 centimeter of media (blotter or filter paper). Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module provides waste water treatment plant operators with…
NASA Astrophysics Data System (ADS)
Reid, Mark; Iverson, Richard; Brien, Dianne; Iverson, Neal; LaHusen, Richard; Logan, Matthew
2017-04-01
Shallow landslides and ensuing debris flows are a common hazard worldwide, yet forecasting their initiation at a specific site is challenging. These challenges arise, in part, from diverse near-surface hydrologic pathways under different wetting conditions, 3D failure geometries, and the effects of suction in partially saturated soils. Simplistic hydrologic models typically used for regional hazard assessment disregard these complexities. As an alterative to field studies where the effects of these governing factors can be difficult to isolate, we used the USGS debris-flow flume to conduct controlled, field-scale landslide initiation experiments. Using overhead sprinklers or groundwater injectors on the flume bed, we triggered failures using three different wetting conditions: groundwater inflow from below, prolonged moderate-intensity precipitation, and bursts of high-intensity precipitation. Failures occurred in 6 m3 (0.65-m thick and 2-m wide) prisms of loamy sand on a 31° slope; these field-scale failures enabled realistic incorporation of nonlinear scale-dependent effects such as soil suction. During the experiments, we monitored soil deformation, variably saturated pore pressures, and moisture changes using ˜50 sensors sampling at 20 Hz. From ancillary laboratory tests, we determined shear strength, saturated hydraulic conductivities, and unsaturated moisture retention characteristics. The three different wetting conditions noted above led to different hydrologic pathways and influenced instrumental responses and failure timing. During groundwater injection, pore-water pressures increased from the bed of the flume upwards into the sediment, whereas prolonged moderate infiltration wet the sediment from the ground surface downward. In both cases, pore pressures acting on the impending failure surface slowly rose until abrupt failure. In contrast, a burst of intense sprinkling caused rapid failure without precursory development of widespread positive pore pressures. Using coupled 2D variably saturated groundwater flow modeling and 3D limit-equilibrium analyses, we simulated the observed hydrologic behaviors and the time evolution of changes in factors of safety. Our measured parameters successfully reproduced pore pressure observations without calibration. We also quantified the mechanical effects of 3D geometry and unsaturated soil suction on stability. Although suction effects appreciably increased the stability of drier sediment, they were dampened (to <10% increase) in wetted sediment. 3D geometry effects from the lateral margins consistently increased factors of safety by >20% in wet or dry sediment. Importantly, both 3D and suction effects enabled more accurate simulation of failure times. Without these effects, failure timing and/or back-calculated shear strengths would be markedly incorrect. Our results indicate that simplistic models could not consistently predict the timing of slope failure given diverse hydrologic pathways. Moreover, high frequency monitoring (with sampling periods < ˜60 s) would be required to measure and interpret the effects of rapid hydrologic triggers, such as intense rain bursts.
Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control
NASA Technical Reports Server (NTRS)
Juhasz, A. J.; Smith, J. M.
1977-01-01
A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.
NASA Technical Reports Server (NTRS)
Iglisch, Rudolf
1949-01-01
Lately it has been proposed to reduce the friction drag of a body in a flow for the technically important large Reynolds numbers by the following expedient: the boundary layer, normally turbulent, is artificially kept laminar up to high Reynolds numbers by suction. The reduction in friction drag thus obtained is of the order of magnitude of 60 to 80 percent of the turbulent friction drag, since the latter, for large Reynolds numbers, is several times the laminar friction drag. In considering the idea mentioned one has first to consider whether suction is a possible means of keeping the boundary layer laminar. This question can be answered by a theoretical investigation of the stability of the laminar boundary layer with suction. A knowledge, as accurate as possible, of the velocity distribution in the laminar boundary layer with suction forms the starting point for the stability investigation. E. Schlichting recently gave a survey of the present state of calculation of the laminar boundary layer with suction.
Ventilation through a small-bore catheter: optimizing expiratory ventilation assistance.
Hamaekers, A E W; Borg, P A J; Götz, T; Enk, D
2011-03-01
Emergency ventilation through a small-bore transtracheal catheter can be lifesaving in a 'cannot intubate, cannot ventilate' situation. Ejectors, capable of creating suction by the Bernoulli principle, have been proposed to facilitate expiration through small-bore catheters. In this bench study, we compared a novel, purpose-built ventilation ejector (DE 5) with a previously proposed, modified industrial ejector (SBP 07). The generated insufflation pressures, suction pressures in static and dynamic situations, and also suction capacities and entrainment ratios of the SBP 07 and the DE 5 were determined. The DE 5 was also tested in a lung simulator with a simulated complete upper airway obstruction. Inspiratory and expiratory times through a transtracheal catheter were measured at various flow rates and achievable minute volumes were calculated. In a static situation, the SBP 07 showed a more negative pressure build-up compared with the DE 5. However, in a dynamic situation, the DE 5 generated a more negative pressure, resulting in a higher suction capacity. Employment of the DE 5 at a flow rate of 18 litre min(-1) allowed a minute volume through the transtracheal catheter of up to 8.27 litre min(-1) at a compliance of 100 ml cm H(2)O(-1). The efficiency of the DE 5 depended on the flow rate of the driving gas and the compliance of the lung simulator. In laboratory tests, the DE 5 is an optimized ventilation ejector suitable for applying expiratory ventilation assistance. Further research may confirm the clinical applicability as a portable emergency ventilator for use with small-bore catheters.
NASA Technical Reports Server (NTRS)
Sakakibara, Seizo; Takashima, Kazuaki; Miwa, Hitoshi; Oguni, Yasuo; Sato, Mamoru; Kanda, Hiroshi
1988-01-01
Experimental data on the flow quality of the National Aerospace Laboratory two-dimensional transonic wind tunnel are presented. Mach number distributions on the test section axis show good uniformity which is characterized by the two sigma (standard deviation) values of 0.0003 to 0.001 for a range of Mach numbers from 0.4 to 1.0. Flow angularities, which were measured by using a wing model with a symmetrical cross section, remained within 0.04 deg for Mach numbers from 0.2 to 0.8. Side wall boundary layer suction was applied through a pair of porous plates. The variation of aerodynamic properties of the model due to the suction mass flow rate change is presented with a brief discussion. Two dimensionality of the flow over the wing span is expected to be improved by applying the appropriate suction rate, which depends on the Mach number, Reynolds number, and lift coefficient.
Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.
DOT National Transportation Integrated Search
2009-09-01
ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...
Gravity separation of pericardial fat in cardiotomy suction blood: an in vitro model.
Kinard, M Rhett; Shackelford, Anthony G; Sistino, Joseph J
2009-06-01
Fat emboli generated during cardiac surgery have been shown to cause neurologic complications in patients postoperatively. Cardiotomy suction has been known to be a large generator of emboli. This study will examine the efficacy of a separation technique in which the cardiotomy suction blood is stored in a cardiotomy reservoir for various time intervals to allow spontaneous separation of fat from blood by density. Soybean oil was added to heparinized porcine blood to simulate the blood of a patient with hypertriglyceridemia (> 150 mg/dL). Roller pump suction was used to transfer the room temperature blood into the cardiotomy reservoir. Blood was removed from the reservoir in 200-mL aliquots at 0, 15, 30 45, and 60 minutes. Samples were taken at each interval and centrifuged to facilitate further separation of liquid fat. Fat content in each sample was determined by a point-of-care triglyceride analyzer. Three trials were conducted for a total of 30 samples. The 0-minute group was considered a baseline and was compared to the other four times. Fat concentration was reduced significantly in the 45- and 60-minute groups compared to the 0-, 15-, and 30-minute groups (p < .05). Gravity separation of cardiotomy suction blood is effective; however, it may require retention of blood for more time than is clinically acceptable during a routing coronary artery bypass graft surgery.
Staab, Katie Lynn; Holzman, Roi; Hernandez, L Patricia; Wainwright, Peter C
2012-05-01
A protrusible upper jaw has independently evolved multiple times within teleosts and has been implicated in the success of two groups in particular: Acanthomorpha and Cypriniformes. We use digital particle image velocimetry (DPIV) to compare suction feeding flow dynamics in a representative of each of these clades: goldfish and bluegill. Using DPIV, we contrast the spatial pattern of flow, the temporal relationship between flow and head kinematics, and the contribution of jaw protrusion to the forces exerted on prey. As expected, the spatial patterns of flow were similar in the two species. However, goldfish were slower to reach maximal kinematic excursions, and were more flexible in the relative timing of jaw protrusion, other jaw movements and suction flows. Goldfish were also able to sustain flow speeds for a prolonged period of time as compared with bluegill, in part because goldfish generate lower peak flow speeds. In both species, jaw protrusion increased the force exerted on the prey. However, slower jaw protrusion in goldfish resulted in less augmentation of suction forces. This difference in force exerted on prey corresponds with differences in trophic niches and feeding behavior of the two species. The bluegill uses powerful suction to capture insect larvae whereas the goldfish uses winnowing to sort through detritus and sediment. The kinethmoid of goldfish may permit jaw protrusion that is independent of lower jaw movement, which could explain the ability of goldfish to decouple suction flows (due to buccal expansion) from upper jaw protrusion. Nevertheless, our results show that jaw protrusion allows both species to augment the force exerted on prey, suggesting that this is a fundamental benefit of jaw protrusion to suction feeders.
Are Prolactin Levels Linked to Suction Pressure?
Zhang, Feng; Xia, Haiou; Shen, Meiyun; Li, Xia; Qin, Ling; Gu, Hongmei; Xu, Xujuan
2016-11-01
Suction pressure has been reported to be a key driving force of lactation. An infant's sucking at its mother's breasts is the major stimulus to post-natal prolactin (PRL) secretion, and PRL is the essential hormone for lactation and milk production. It is unknown what role suction pressure has in PRL secretion and milk supply postnatally. To explore the relationship between the suction pressure, PRL level, lactation, and milk supply in breastfeeding mother-infant dyads. Healthy women with normal full-term infants were enrolled (n = 122). Data collection included suction pressure, PRL level, and the mother's perception of both the onset of her lactation and her milk supply at 1 month. Suction pressure was measured with a pressure sensor connected to a tube placed alongside the nipple. The chemiluminescence method was used to quantify maternal serum PRL level both before and after a breastfeed to explore the effect of suckling on PRL increment. The mother's perception of the onset of her lactation was evaluated by the mother's sense of fullness in her breast. The mother's perception of milk supply was evaluated by using the H&H Lactation Scale. Data from 117 participants were included in this analysis. Low suction pressure, a shorter gestational age, a high pre-gestational body mass index (BMI), and high infant birth weight were associated with a smaller than average PRL increment. High suction pressure, longer sucking duration, and a low gestational weight gain were related to a mother's perception of an earlier onset of her lactation. However, low suction pressure, a high frequency of giving formula, a small PRL increment, and the mother's perception of a later onset of her lactation were correlated with her perception of an insufficient milk supply. Suction pressure varied directly with the post-natal PRL increment. Suction pressure was associated with the timing of the mother's perception of her lactation. Strong suction pressure by the infant is likely to enhance the mother's confidence in her lactation. Additionally, sucking duration, frequency of giving formula, maternal BMI, and infant birth weight played a role in early breastfeeding success.
NASA Astrophysics Data System (ADS)
Greco, Roberto; Gargano, Rudy
2016-04-01
The evaluation of suction stress in unsaturated soils has important implications in several practical applications. Suction stress affects soil aggregate stability and soil erosion. Furthermore, the equilibrium of shallow unsaturated soil deposits along steep slopes is often possible only thanks to the contribution of suction to soil effective stress. Experimental evidence, as well as theoretical arguments, shows that suction stress is a nonlinear function of matric suction. The relationship expressing the dependence of suction stress on soil matric suction is usually indicated as Soil Stress Characteristic Curve (SSCC). In this study, a novel equation for the evaluation of the suction stress of an unsaturated soil is proposed, assuming that the exchange of stress between soil water and solid particles occurs only through the part of the surface of the solid particles which is in direct contact with water. The proposed equation, based only upon geometric considerations related to soil pore-size distribution, allows to easily derive the SSCC from the water retention curve (SWRC), with the assignment of two additional parameters. The first parameter, representing the projection of the external surface area of the soil over a generic plane surface, can be reasonably estimated from the residual water content of the soil. The second parameter, indicated as H0, is the water potential, below which adsorption significantly contributes to water retention. For the experimental verification of the proposed approach such a parameter is considered as a fitting parameter. The proposed equation is applied to the interpretation of suction stress experimental data, taken from the literature, spanning over a wide range of soil textures. The obtained results show that in all cases the proposed relationships closely reproduces the experimental data, performing better than other currently used expressions. The obtained results also show that the adopted values of the parameter H0, allowing for a good fitting of the experimental data, are in agreement with the values of water potential marking the limit between capillary and adsorptive soil water retention, which can be estimated from the shape of the water retention curve. Therefore, with the proposed approach, at least in principle it is possible to derive the SSSC directly from the knowledge of the SWRC.
Intermittent patient suction system, self-contained control
Lewis, Jay L.
1992-01-01
An intermittent patient suction system, a self-contained control device therefor and methods of making the same are provided, the self-contained control device having a housing that contains two restrictor units therein for respectively controlling the "on" time and "off" time that the control device applies a vacuum and does not apply a vacuum through the output of the control device to the patient.
Suction on chest drains following lung resection: evidence and practice are not aligned.
Lang, Peter; Manickavasagar, Menaka; Burdett, Clare; Treasure, Tom; Fiorentino, Francesca
2016-02-01
A best evidence topic in Interactive CardioVascular and Thoracic Surgery (2006) looked at application of suction to chest drains following pulmonary lobectomy. After screening 391 papers, the authors analysed six studies (five randomized controlled trials [RCTs]) and found no evidence in favour of postoperative suction in terms of air leak duration, time to chest drain removal or length of stay. Indeed, suction was found to be detrimental in four studies. We sought to determine whether clinical practice is consistent with published evidence by surveying thoracic units nationally and performing a meta-analysis of current best evidence. We systematically searched MEDLINE, EMBASE and CENTRAL for RCTs, comparing outcomes with and without application of suction to chest drains after lung surgery. A meta-analysis was performed using RevMan(©) software. A questionnaire concerning chest drain management and suction use was emailed to a clinical representative in every thoracic unit. Eight RCTs, published 2001-13, with 31-500 participants, were suitable for meta-analysis. Suction prolonged length of stay (weighted mean difference [WMD] 1.74 days; 95% confidence interval [CI] 1.17-2.30), chest tube duration (WMD 1.77 days; 95% CI 1.47-2.07) and air leak duration (WMD 1.47 days; 95% CI 1.45-2.03). There was no difference in occurrence of prolonged air leak. Suction was associated with fewer instances of postoperative pneumothorax. Twenty-five of 39 thoracic units responded to the national survey. Suction is routinely used by all surgeons in 11 units, not by any surgeon in 5 and by some surgeons in 9. Of the 91 surgeons represented, 62 (68%) routinely used suction. Electronic drains are used in 15 units, 10 of which use them routinely. Application of suction to chest drains following non-pneumonectomy lung resection is common practice. Suction has an effect in hastening the removal of air and fluid in clinical experience but a policy of suction after lung resection has not been shown to offer improved clinical outcomes. Clinical practice is not aligned with Level 1a evidence. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Instabilities orginating from suction holes used for Laminar Flow Control (LFC)
NASA Technical Reports Server (NTRS)
Watmuff, Jonathan H.
1994-01-01
A small-scale wind tunnel previously used for turbulent boundary layer studies has been modified for experiments in laminar flow control. The facility incorporates suction through interchangeable porous test surfaces which are used to stabilize the boundary layer and delay transition to turbulent flow. The thin porous test surfaces are supported by a baffled plenum chamber box which also acts to gather the flow through the surface into tubes which are routed to a high pressure fan. An elliptic leading edge is attached to the assembly to establish a new layer on the test plate. A slot is used to remove the test section flow below the leading edge. The test section was lengthened and fitted with a new ceiling. Substantial modifications were also made to the 3D probe traverse. Detailed studies have been made using isolated holes to explore the underlying instability mechanisms. The suction is perturbed harmonically and data are averaged on the basis of the phase of the disturbance. Conditions corresponding to strong suction and without suction have been studied. In both cases, 3D contour surfaces in the vicinity of the hole show highly three-dimensional T-S waves that fan out away from the hole with streamwise distance. With suction, the perturbations on the centerline are much stronger and decay less rapidly, while the far field is similar to the case without suction. Downstream the contour surfaces of the bow-shaped TS waves develop spanwise irregularities which eventually form into clumps. The contours remain smooth when suction is not applied. Even without suction, the harmonic point source is challenging for CFD; e.g. DNS has been used for streamwise growth. With suction, grid resources are consumed by the hole and this makes DNS even more expensive. Limited DNS results so far indicate that the vortices which emanate from suction holes appear to be stable. The spanwise clumping observed in the experiment is evidence of a secondary instability that could be associated with suction vortices. A typical porous surface for LFC consists of 0.002 inch diameter holes with 0.020 inch grid spacing L, which is too small to resolve disturbances. A 20:1 scale porous test surface has been machined for improved spatial resolution while the L/d is still representative of flight conditions. Designers of porous surfaces use Goldsmith's criterion to minimize crossstream interaction. However nothing is known about the streamwise interactions. Results using two holes, aligned but displaced in the streamwise direction, indicate that partial TS wave cancellation is possible, depending on the hole spacing and disturbance frequency. Using DNS for streamwise interaction studies will be prohibitively expensive if linear superposition cannot be used for the multiple holes.
NASA Astrophysics Data System (ADS)
Pekkan, Kerem; Chang, Brian; Uslu, Fazil; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi
2016-07-01
The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larvae (2500-20,000 μm total length) are reported using time-resolved microscopic particle image velocimetry. For the larval stages studied, the maximum peak suction velocity of the inflow bolus is measured at a finite distance from the mouth tip and ranges from 1 to 8 mm/s. The average pressure gradient and the velocity profile proximal to the buccal (mouth) cavity are calculated, and two distinct trends are identified. External recirculation regions and reverse flow feeding cycles are also observed and quantified. One of the unresolved questions in fish suction feeding is the shape and dynamics of the buccal cavity during suction feeding; optical coherence tomography imaging is found to be useful for reconstructing the mouth kinematics. The projected area of the mouth cavity during the feeding cycle varies up to 160 and 22 % for the transverse and mid-sagittal planes, respectively. These findings can inspire novel hydrodynamically efficient biomedical and microfluidic devices.
Boundary-layer receptivity due to a wall suction and control of Tollmien-Schlichting waves
NASA Technical Reports Server (NTRS)
Bodonyi, R. J.; Duck, P. W.
1992-01-01
A numerical study of the generation of Tollmien-Schlichting (T-S) waves due to the interaction between a small free-stream disturbance and a small localized suction slot on an otherwise flat surface was carried out using finite difference methods. The nonlinear steady flow is of the viscous-inviscid interactive type while the unsteady disturbed flow is assumed to be governed by the Navier-Stokes equations linearized about this flow. Numerical solutions illustrate the growth or decay of T-S waves generated by the interaction between the free-stream disturbance and the suction slot, depending on the value of the scaled Strouhal number. An important result of this receptivity problem is the numerical determination of the amplitude of the T-S waves and the demonstration of the possible active control of the growth of T-S waves.
Boundary-layer receptivity due to a wall suction and control of Tollmien-Schlichting waves
NASA Technical Reports Server (NTRS)
Bodonyi, R. J.; Duck, P. W.
1990-01-01
A numerical study of the generation of Tollmien-Schlichting (T-S) waves due to the interaction between a small free-stream disturbance and a small localized suction slot on an otherwise flat surface was carried out using finite difference methods. The nonlinear steady flow is of the viscous-inviscid interactive type while the unsteady disturbed flow is assumed to be governed by the Navier-Stokes equations linearized about this flow. Numerical solutions illustrate the growth or decay of T-S waves generated by the interaction between the free-stream disturbance and the suction slot, depending on the value of the scaled Strouhal number. An important result of this receptivity problem is the numerical determination of the amplitude of the T-S waves and the demonstration of the possible active control of the growth of T-S waves.
Rabach, Lesley; Siegel, Mark D; Puchalski, Jonathan T; Towle, Dana; Follert, Michelle; Johnson, Kelsey M; Rademaker, Alfred W; Leder, Steven B
2015-06-01
Preventing pulmonary complications during mechanical ventilation via tracheotomy is a high priority. To investigate if the Blom tracheotomy tube with suction-above-the-cuff inner cannula reduced the quantity of normal flora and pathogens in supra- versus subglottic spaces. We enrolled 20 consecutive medical ICU adults requiring tracheostomy for mechanical ventilation in this proof-of-concept, prospective, single-center study. All participants received a Blom tracheotomy tube with suction-above-the-cuff inner cannula to decontaminate microorganisms from the supra- and subglottic spaces. Supra- and subglottic sputum samples were obtained for microbiologic analysis while an endotracheal tube was in place before tracheotomy and once per week for up to 4 weeks of mechanical ventilation after tracheotomy. Demographics, duration of endotracheal tube intubation, and duration of mechanical ventilation post-tracheotomy were recorded. There was a significant reduction for supraglottic (2.86 ± 1.11 [mean ± SD]) versus subglottic suction samples (2.48 ± 1.07) (paired t test, P = 0.048; Wilcoxon test, P = 0.045) when all data pairs for normal flora and pathogens were combined across times. There was a significant reduction of normal flora pooled across times in 19 data pairs for supraglottic (3.00 ± 1.05) versus subglottic suction samples (2.00 ± 0.94) (paired t test, P = 0.0004; Wilcoxon test, P = 0.0007). There was no significant reduction of pathogens pooled across times in 25 data pairs for supraglottic (2.76 ± 1.16) versus subglottic suction samples (2.84 ± 1.03) (paired t test, P = 0.75; Wilcoxon test, P = 0.83). Proof-of-concept was confirmed. The Blom tracheotomy tube with disposable suction-above-the-cuff inner cannula decontaminated microorganisms from the subglottic space when normal flora and pathogens were combined. Future research should investigate if decreased quantity of normal flora and pathogens in the subglottic space reduces the incidence of ventilator-associated pulmonary complications in critically ill patients requiring ongoing mechanical ventilation via tracheotomy.
Surgical treatment of axillary hyperhidrosis by suction-curettage of sweat glands*
de Rezende, Rebeca Maffra; Luz, Flávio Barbosa
2014-01-01
Suction curettage is a dermatologic surgery technique for the treatment of axillary hyperhidrosis, which is becoming more popular. Objective: The purpose of this study is to describe the current technique of removal of axillary sweat glands, and evaluate its efficacy and safety. Conclusion: Suction-curettage of sweat glands is a minimally invasive surgical technique that is easy to perform, safe, has high rates of success and relatively few side-effects. It is generally well tolerated by patients and requires shorter time away from daily activities, when compared with other surgical modalities. PMID:25387499
NASA Astrophysics Data System (ADS)
Oberlack, Martin; Nold, Andreas; Sanjon, Cedric Wilfried; Wang, Yongqi; Hau, Jan
2016-11-01
Classical hydrodynamic stability theory for laminar shear flows, no matter if considering long-term stability or transient growth, is based on the normal-mode ansatz, or, in other words, on an exponential function in space (stream-wise direction) and time. Recently, it became clear that the normal mode ansatz and the resulting Orr-Sommerfeld equation is based on essentially three fundamental symmetries of the linearized Euler and Navier-Stokes equations: translation in space and time and scaling of the dependent variable. Further, Kelvin-mode of linear shear flows seemed to be an exception in this context as it admits a fourth symmetry resulting in the classical Kelvin mode which is rather different from normal-mode. However, very recently it was discovered that most of the classical canonical shear flows such as linear shear, Couette, plane and round Poiseuille, Taylor-Couette, Lamb-Ossen vortex or asymptotic suction boundary layer admit more symmetries. This, in turn, led to new problem specific non-modal ansatz functions. In contrast to the exponential growth rate in time of the modal-ansatz, the new non-modal ansatz functions usually lead to an algebraic growth or decay rate, while for the asymptotic suction boundary layer a double-exponential growth or decay is observed.
Endotracheal suctioning in intubated newborns: an integrative literature review
Gonçalves, Roberta Lins; Tsuzuki, Lucila Midori; Carvalho, Marcos Giovanni Santos
2015-01-01
Evidence-based practices search for the best available scientific evidence to support problem solving and decision making. Because of the complexity and amount of information related to health care, the results of methodologically sound scientific papers must be integrated by performing literature reviews. Although endotracheal suctioning is the most frequently performed invasive procedure in intubated newborns in neonatal intensive care units, few Brazilian studies of good methodological quality have examined this practice, and a national consensus or standardization of this technique is lacking. Therefore, the purpose of this study was to review secondary studies on the subject to establish recommendations for endotracheal suctioning in intubated newborns and promote the adoption of best-practice concepts when conducting this procedure. An integrative literature review was performed, and the recommendations of this study are to only perform endotracheal suctioning in newborns when there are signs of tracheal secretions and to avoid routinely performing the procedure. In addition, endotracheal suctioning should be conducted by at least two people, the suctioning time should be less than 15 seconds, the negative suction pressure should be below 100 mmHg, and hyperoxygenation should not be used on a routine basis. If indicated, oxygenation is recommended with an inspired oxygen fraction value that is 10 to 20% greater than the value of the previous fraction, and it should be performed 30 to 60 seconds before, during and 1 minute after the procedure. Saline instillation should not be performed routinely, and the standards for invasive procedures must be respected. PMID:26465249
Manning, K; Birkenheuer, A J; Briley, J; Montgomery, S A; Harris, J; Vanone, S L; Gookin, J L
2016-09-01
Megaesophagus carries a poor to guarded prognosis due to death from aspiration pneumonia. Options for medical management of regurgitation are limited to strategic oral or gastrostomy tube feeding. To describe the use and efficacy of intermittent esophageal suctioning to prevent regurgitation and associated episodes of aspiration pneumonia in dogs with megaesophagus. Four dogs with acquired idiopathic megaesophagus and recurrent aspiration pneumonia. Retrospective review of medical records of dogs with megaesophagus in which intermittent suctioning of esophageal content was employed for management of recurrent aspiration pneumonia. Intermittent suctioning of the esophagus was initiated in 4 dogs after failure of strict gastrostomy tube feeding failed to prevent regurgitation and repeated episodes of aspiration pneumonia. Suctioning was accomplished by esophagostomy tube in 3 dogs and per os in 1 dog. After initiation of esophageal suctioning, dogs survived for a median of 13.5 additional months (range, 10-30 months) during which time 2 dogs had no additional episodes of aspiration pneumonia and 2 dogs had infrequent episodes of pneumonia, but aspiration was suspected to be a contributing factor in their death. Complications included clogging of the esophagostomy tube, esophagostomy site infections, and esophagitis. Use of intermittent esophageal suctioning in dogs with megaesophagus that continue to regurgitate despite gastrostomy tube feedings can reduce or abolish clinical episodes of aspiration pneumonia. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Fox, Melanie J; Scarvell, Jennie M; Smith, Paul N; Kalyanasundaram, Shankar; Stachurski, Zbigniew H
2013-08-30
Internal fixation of femoral fractures requires drilling holes through the cortical bone of the shaft of the femur. Intramedullary suction reduces the fat emboli produced by reaming and nailing femoral fractures but requires four suction portals to be drilled into the femoral shaft. This work investigated the effect of these additional holes on the strength of the femur. Finite element analysis (FEA) was used to calculate compression, tension and load limits which were then compared to the results from mechanical testing. Models of intact femora and fractured femora internally fixed with intramedullary nailing were generated. In addition, four suction portals, lateral, anterior and posterior, were modelled. Stresses were used to calculate safety factors and predict fatigue. Physical testing on synthetic femora was carried out on a universal mechanical testing machine. The FEA model for stresses generated during walking showed tensile stresses in the lateral femur and compression stresses in the medial femur with a maximum sheer stress through the neck of the femur. The lateral suction portals produced tensile stresses up to over 300% greater than in the femur without suction portals. The anterior and posterior portals did not significantly increase stresses. The lateral suction portals had a safety factor of 0.7, while the anterior and posterior posts had safety factors of 2.4 times walking loads. Synthetic bone subjected to cyclical loading and load to failure showed similar results. On mechanical testing, all constructs failed at the neck of the femur. The anterior suction portals produced minimal increases in stress to loading so are the preferred site should a femur require such drill holes for suction or internal fixation.
Suction generation in white-spotted bamboo sharks Chiloscyllium plagiosum.
Wilga, Cheryl D; Sanford, Christopher P
2008-10-01
After the divergence of chondrichthyans and teleostomes, the structure of the feeding apparatus also diverged leading to alterations in the suction mechanism. In this study we investigated the mechanism for suction generation during feeding in white-spotted bamboo sharks, Chiloscyllium plagiosum and compared it with that in teleosts. The internal movement of cranial elements and pressure in the buccal, hyoid and pharyngeal cavities that are directly responsible for suction generation was quantified using sonomicrometry and pressure transducers. Backward stepwise multiple linear regressions were used to explore the relationship between expansion and pressure, accounting for 60-96% of the variation in pressure among capture events. The progression of anterior to posterior expansion in the buccal, hyoid and pharyngeal cavities is accompanied by the sequential onset of subambient pressure in these cavities as prey is drawn into the mouth. Gape opening triggers the onset of subambient pressure in the oropharyngeal cavities. Peak gape area coincides with peak subambient buccal pressure. Increased velocity of hyoid area expansion is primarily responsible for generating peak subambient pressure in the buccal and hyoid regions. Pharyngeal expansion appears to function as a sink to receive water influx from the mouth, much like that of compensatory suction in bidirectional aquatic feeders. Interestingly, C. plagiosum generates large suction pressures while paradoxically compressing the buccal cavity laterally, delaying the time to peak pressure. This represents a fundamental difference from the mechanism used to generate suction in teleost fishes. Interestingly, pressure in the three cavities peaks in the posterior to anterior direction. The complex shape changes that the buccal cavity undergoes indicate that, as in teleosts, unsteady flow predominates during suction feeding. Several kinematic variables function together, with great variation over long gape cycles to generate the low subambient pressures used by C. plagiosum to capture prey.
Experimental Study of a Nozzle Using Fluidic Counterflow for Thrust Vectoring
NASA Technical Reports Server (NTRS)
Flamm, Jeffrey D.
1998-01-01
A static experimental investigation of a counterflow thrust vectoring nozzle concept was performed. The study was conducted in the NASA Langley Research Center Jet Exit Test Facility. Internal performance characteristics were defined over a nozzle pressure ratio (jet total to ambient) range of 3.5 to 10.0. The effects of suction collar geometry and suction slot height on nozzle performance were examined. In the counterflow concept, thrust vectoring is achieved by applying a vacuum to a slot adjacent to a primary jet that is shrouded by a suction collar. Two flow phenomena work to vector the primary jet depending upon the test conditions and configuration. In one case, the vacuum source creates a secondary reverse flowing stream near the primary jet. The shear layers between the two counterflowing streams mix and entrain mass from the surrounding fluid. The presence of the collar inhibits mass entrainment and the flow near the collar accelerates, causing a drop in pressure on the collar. The second case works similarly except that the vacuum is not powerful enough to create a counterflowing stream and instead a coflowing stream is present. The primary jet is vectored if suction is applied asymmetrically on the top or bottom of the jet.
Temporal pattern of soil matric suction in the unsaturated soil slope under different forest cover
NASA Astrophysics Data System (ADS)
Hayati, Elyas; Abdi, Ehsan; Mohseni Saravi, Mohsen; Nieber, John; Majnounian, Baris; Chirico, Giovanni
2017-04-01
In the vadose zone, usually, soils experience high matric suction during dry periods which results in a significant additional soil strength component (i.e., apparent cohesion) and thus plays a crucial role in the stability of unsaturated soil slopes. But, in the wet periods, when rain-water infiltrates into the soil, the matric suction of the soil dissipates partially or completely. It is a well-understood concept that vegetation can modify the hillslope hydrology and subsequent stability conditions by increasing soil matric suction through both interception of rainfall and depletion of soil water content via transpiration. Anthropogenic pressures, particularly clear-cutting and deforestation, affect many hydro-geomorphological processes including catchment and hillslope hydrology and stability. However, quantifying the changes in soil hydrologic conditions and the resulted stability of slopes due to these degrading activities remained an unresolved problem. To address this gap, a continuous measurement of soil water dynamics has been conducted at two adjacent hillslopes (one forested hillslope and one degraded hillslope) using PR2/6 profile probe for a 9-month period of time to demonstrate the forest cover-specific influence on the hillslope hydrology and stability during different seasons. The results have been then presented in terms of estimated soil matric suction to facilitate analyzing the resulted stability states due to the changes in soil water balance with time in the two studied hillslopes. The data were tested to check whether there are any differences between the forested and degraded hillslopes in terms of soil matric suction and augmented soil cohesion during different seasons. Finally, the response of soil hydrologic condition and the resulted slope stability for the 9-month period were analyzed and discussed for the different hillslopes.
Mo, Xiaoliang; Qin, Guirong; Zhou, Zhoulin; Jiang, Xiaoli
2017-10-03
To explore the risk factors for intrauterine adhesions in patients with artificial abortion and clinical efficacy of hysteroscopic dissection. 1500 patients undergoing artificial abortion between January 2014 and June 2015 were enrolled into this study. The patients were divided into two groups with or without intrauterine adhesions. Univariate and Multiple logistic regression were conducted to assess the effects of multiple factors on the development of intrauterine adhesions following induced abortion. The incidence rate for intrauterine adhesions following induced abortion is 17.0%. Univariate showed that preoperative inflammation, multiple pregnancies and suction evacuation time are the influence risk factors of intrauterine adhesions. Multiple logistic regression demonstrates that multiple pregnancies, high intrauterine negative pressure, and long suction evacuation time are independent risk factors for the development of intrauterine adhesions following induced abortion. Additionally, intrauterine adhesions were observed in 105 mild, 80 moderate, and 70 severe cases. The cure rates for these three categories of intrauterine adhesions by hysteroscopic surgery were 100.0%, 93.8%, and 85.7%, respectively. Multiple pregnancies, high negative pressure suction evacuation and long suction evacuation time are independent risk factors for the development of intrauterine adhesions following induced abortions. Hysteroscopic surgery substantially improves the clinical outcomes of intrauterine adhesions.
Boundary layer transition studies
NASA Technical Reports Server (NTRS)
Watmuff, Jonathan H.
1995-01-01
A small-scale wind tunnel previously used for turbulent boundary layer experiments was modified for two sets of boundary layer transition studies. The first study concerns a laminar separation/turbulent reattachment. The pressure gradient and unit Reynolds number are the same as the fully turbulent flow of Spalart and Watmuff. Without the trip wire, a laminar layer asymptotes to a Falkner & Skan similarity solution in the FPG. Application of the APG causes the layer to separate and a highly turbulent and approximately 2D mean flow reattachment occurs downstream. In an effort to gain some physical insight into the flow processes a small impulsive disturbance was introduced at the C(sub p) minimum. The facility is totally automated and phase-averaged data are measured on a point-by-point basis using unprecedently large grids. The evolution of the disturbance has been tracked all the way into the reattachment region and beyond into the fully turbulent boundary layer. At first, the amplitude decays exponentially with streamwise distance in the APG region, where the layer remains attached, i.e. the layer is viscously stable. After separation, the rate of decay slows, and a point of minimum amplitude is reached where the contours of the wave packet exhibit dispersive characteristics. From this point, exponential growth of the amplitude of the disturbance is observed in the detached shear layer, i.e. the dominant instability mechanism is inviscid. A group of large-scale 3D vortex loops emerges in the vicinity of the reattachment. Remarkably, the second loop retains its identify far downstream in the turbulent boundary layer. The results provide a level of detail usually associated with CFD. Substantial modifications were made to the facility for the second study concerning disturbances generated by Suction Holes for laminar flow Control (LFC). The test section incorporates suction through interchangeable porous test surfaces. Detailed studies have been made using isolated holes in the impervious test plate that used to establish the Blasius base flow. The suction is perturbed harmonically and data are averaged on the basis of the phase of the disturbance, for conditions corresponding to strong suction and without suction. The technique was enhanced by using up to nine multiple probes to reduce the experimental run-time. In both cases, 3D contour surfaces in the vicinity of the hole show highly 3D TS waves which fan out in the spanwise direction forming bow-shaped waves downstream. The case without suction has proved useful for evaluating calculation methods. With suction, the perturbations on the centerline are much stronger and decay less rapidly, while the TS waves in the far field are similar to the case without suction. Downstream, the contour surfaces of the TS waves develop spanwise irregularities which eventually form into clumps. The spanwise clumping is evidence of a secondary instability that could be associated with suction vortices. Designers of porous surfaces use Goldsmith's Criterion to minimize cross-stream interactions. It is shown that partial TS wave cancellation is possible, depending on the hole spacing, disturbance frequency and free-stream velocity. New high-performance Constant Temperature Hot-Wire Anemometers were designed and built, based on a linear system theory analysis that can be extended to arbitrary order. The motivation was to achieve the highest possible frequency reponse while ensuring overall system stability. The performance is equal to or superior to commercially available instruments at about 10% of the cost. Details, such as fabrication drawings and a parts list, have been published to enable the instrument to be construced by others.
Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh
2014-09-01
Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.
Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh
2014-01-01
Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea. PMID:25276759
Simulations of turbulent asymptotic suction boundary layers
NASA Astrophysics Data System (ADS)
Bobke, Alexandra; Örlü, Ramis; Schlatter, Philipp
2016-02-01
A series of large-eddy simulations of a turbulent asymptotic suction boundary layer (TASBL) was performed in a periodic domain, on which uniform suction was applied over a flat plate. Three Reynolds numbers (defined as ratio of free-stream and suction velocity) of Re = 333, 400 and 500 and a variety of domain sizes were considered in temporal simulations in order to investigate the turbulence statistics, the importance of the computational domain size, the arising flow structures as well as temporal development length required to achieve the asymptotic state. The effect of these two important parameters was assessed in terms of their influence on integral quantities, mean velocity, Reynolds stresses, higher order statistics, amplitude modulation and spectral maps. While the near-wall region up to the buffer region appears to scale irrespective of Re and domain size, the parameters of the logarithmic law (i.e. von Kármán and additive coefficient) decrease with increasing Re, while the wake strength decreases with increasing spanwise domain size and vanishes entirely once the spanwise domain size exceeds approximately two boundary-layer thicknesses irrespective of Re. The wake strength also reduces with increasing simulation time. The asymptotic state of the TASBL is characterised by surprisingly large friction Reynolds numbers and inherits features of wall turbulence at numerically high Re. Compared to a turbulent boundary layer (TBL) or a channel flow without suction, the components of the Reynolds-stress tensor are overall reduced, but exhibit a logarithmic increase with decreasing suction rates, i.e. increasing Re. At the same time, the anisotropy is increased compared to canonical wall-bounded flows without suction. The reduced amplitudes in turbulence quantities are discussed in light of the amplitude modulation due to the weakened larger outer structures. The inner peak in the spectral maps is shifted to higher wavelength and the strength of the outer peak is much less than for TBLs. An additional spatial simulation was performed, in order to relate the simulation results to wind tunnel experiments, which - in accordance with the results from the temporal simulation - indicate that a truly TASBL is practically impossible to realise in a wind tunnel. Our unique data set agrees qualitatively with existing literature results for both numerical and experimental studies, and at the same time sheds light on the fact why the asymptotic state could not be established in a wind tunnel experiment, viz. because experimental studies resemble our simulation results from too small simulation boxes or insufficient development times.
Lakshminrusimha, Satyan; Mathew, Bobby; Nair, Jayasree; Gugino, Sylvia F.; Koenigsknecht, Carmon; Rawat, Munmun; Nielsen, Lori; Swartz, Daniel D.
2014-01-01
Background Current neonatal resuscitation guidelines recommend tracheal suctioning of non-vigorous neonates born through meconium stained amniotic fluid. Methods We evaluated the effect of tracheal suctioning at birth in 29 lambs with asphyxia induced by cord occlusion and meconium aspiration during gasping. Results Tracheal suctioning at birth (n=15) decreased amount of meconium in distal airways (53±29 particles/mm2 lung area) compared to no-suction (499±109 particles/mm2, n=14, p<0.001). Three lambs in the suction group had cardiac arrest during suctioning requiring chest compressions and epinephrine. Onset of ventilation was delayed in the suction group (146±11 vs. 47±3 sec in no-suction group, p=0.005). There was no difference in pulmonary blood flow, carotid blood flow, pulmonary or systemic blood pressure between the two groups. Left atrial pressure was significantly higher in the suction group. Tracheal suctioning resulted in higher PaO2/FiO2 levels (122±21 vs. 78±10 mmHg) and ventilator efficiency index (0.3±0.05 vs.0.16±0.03). Two lambs in the no-suction group required inhaled NO. Lung 3-nitrotyrosine levels were higher in the suction group (0.65±0.03 ng/μg protein) compared to the no-suction group (0.47 ± 0.06). Conclusion Tracheal suctioning improves oxygenation and ventilation. Suctioning does not improve pulmonary/systemic hemodynamics or oxidative stress in an ovine model of acute meconium aspiration with asphyxia. PMID:25406897
Forceps biopsy and suction catheter for sampling in pulmonary nodules and infiltrates.
Peschke, Antje; Wiedemann, Bärbel; Höffken, Gert; Koschel, Dirk
2012-06-01
Transbronchial lung biopsy with forceps is a standard procedure in bronchoscopic tissue sampling. Suction catheter aspiration is another technique, but it is not widely known and almost no data exist regarding its diagnostic efficiency. 272 patients were included in a prospective and randomised study between February 2007 and October 2009. All were referred for bronchoscopic evaluation of pulmonary nodules/masses or infiltrates. We compared the diagnostic yield of forceps biopsy and suction catheter aspiration for a definite diagnosis and looked at whether such a diagnosis depends on the underlying pulmonary change. All patients underwent bronchoscopy with forceps biopsy and catheter aspiration. A definitive diagnosis was reached in a total of 183 (67.3%) patients, with catheter aspiration in 140 (51.5%) patients and with forceps biopsy in 136 (50.0%) patients. In 90 (33.1%) patients, a definite diagnosis could only be reached with the combination of both techniques. The diagnostic yield of forceps biopsy was better than catheter aspiration in infiltrates (p = 0.027), but was no different in nodules or masses (p = 0.09). Suction catheter aspiration is a useful technique of bronchoscopic tissue sampling. The combination of catheter aspiration and forceps biopsy results in a higher diagnostic yield than either method used alone.
Nay, M-A; Auvet, A; Mankikian, J; Herve, V; Dequin, P-F; Guillon, A
2017-06-01
Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better-designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick-shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow. © 2017 The Association of Anaesthetists of Great Britain and Ireland.
Suction and cohesion demise in desaturating granular medium
NASA Astrophysics Data System (ADS)
Hueckel, T.; Mielniczuk, B.; El-Youssoufi, S. M.
2017-12-01
Continuum mechanics for unsaturated soils is based on the assumption of a one-to-one relationship betwee saturation degree and suction represented by the characteristic curve. Such curve commonly shows exceedingly high values of suction at saturation decreasing below 10%. We have performed a series of experiments on physical micro-structural models of 8-, 5, 4, 3, and 2-grain assemblies filled with water forming capillary, funicular and pendular bridges. Dynamic variables characterizing the evolution include: Laplace pressure, surface tension force, total intergralular force, contact angle and contact perimeter length. The Laplace pressure was calculated from the directly measured curvatures of interface surface for 2-grain bridges, and estimated from tomography stills for 3 grain bridges. The initial negative Laplace pressure (suction) as well as total intergranular force increase modestly at the begining of evaporation, but undergo an unstable decrease at the advanced stage, often with a jump in the force known as a Haines jumps since 1925. Laplace pressure turns into positive values prior to rupture for 2-grain bodies. For 3-grain bridges there is never an exceedingly high intergranular force of suction, reported in macro-scale experiments. For multiple-grain bodies there are two types of instabilities, depending on densitiy of the assembly and the Gaussian curvature (GC): at positive GC points it is thin-sheet instability, while at negative GC points instability is linked with air entry fingers, all associated with the split of assemblies into smaller isolated funicular, and eventually pendular bodies. The multi-grain bridges instabilities are linked to material drying cracking, the instabilities in 2 grain systems mean eventual loss of cohesion.
Liposuction devices: technology update
Shridharani, Sachin M; Broyles, Justin M; Matarasso, Alan
2014-01-01
Since its introduction by Illouz and others over 30 years ago, suction-assisted lipectomy/liposuction/lipoplasty has evolved tremendously and has developed into one of the most popular procedures in aesthetic plastic surgery. Liposuction is an effective procedure employed to treat localized adipose deposits in patients not suffering from generalized obesity. These accumulations of subcutaneous fat often occur in predictable distributions in both men and women. A cannula connected to a suction-generating source allows for small incisions to be strategically placed and large volumes of fat to be removed. This fat removal leads to improved harmonious balance of a patient’s physique and improved body contour. Various surgical techniques are available and have evolved as technology has improved. Current technology for liposuction includes suction-assisted lipectomy, ultrasound-assisted, power-assisted, laser-assisted, and radiofrequency-assisted. The choice of technology and technique often depends on patient characteristics and surgeon preference. The objective of this review is to provide a thorough assessment of current technologies available to plastic surgeons performing liposuction. PMID:25093000
NASA research on viscous drag reduction
NASA Technical Reports Server (NTRS)
Petersen, R. H.; Maddalon, D. V.
1982-01-01
Research on natural laminar flow, laminar flow control by suction, and turbulent drag reduction is discussed. Preliminary results suggest that a significant amount of natural laminar flow can be achieved on small, straight wing airplanes. On larger, swept wing aircraft, laminar flow control by distributed suction is expected to result in significant fuel savings. The area over which laminar flow control is applied depends on tradeoffs involving structural complexity, maintenance, and cost. Several methods of reducing turbulent skin friction by altering the turbulence structure itself have shown promise in exploratory testing. The status of these technologies and the benefits of applying them to future aircraft are reviewed.
Evolution of Delivery Room Management for Meconium-Stained Infants: Recent Updates.
Chabra, Shilpi
2018-06-08
The approach to intrapartum and postnatal management of an infant born through meconium-stained amniotic fluid (MSAF) in the delivery room (DR) has changed several times over the last few decades, leading to confusion and anxiety among health care providers (nurses, nurse practitioners, respiratory therapists, midwives, and physicians). This article provides state-of-the-art insight into the evidence or lack thereof for the changes in guidelines. To discuss the evidence for evolution of DR management of vigorous and nonvigorous infants born through any type of MSAF. Review of guidelines from the Neonatal Resuscitation Program of the American Academy of Pediatrics and the American College of Obstetricians and Gynecologists, the International Liaison Committee on Resuscitation, Consensus on Science and Treatment Recommendations, and textbooks of neonatal resuscitation and research using MEDLINE via PubMed. In pregnancies complicated by MSAF, intrapartum suctioning of the oro- and nasopharynx and postnatal intubation with tracheal suctioning of infants have been traditionally used to clear the airway and decrease meconium aspiration syndrome. The recommendations for these perinatal practices have changed several times due to some evidence that the procedures are not beneficial and may even be harmful. Intrapartum suctioning and postnatal tracheal suctioning of infants (vigorous or nonvigorous) born through MSAF are not recommended. This is a "high-risk" delivery requiring 2 team members to be present at birth-one with full resuscitation skills including tracheal intubation. Need to evaluate effects of discontinuing the practice of tracheal suctioning in nonvigorous infants on the incidence of meconium aspiration syndrome and neonatal mortality.
Control of the mixing time in vessels agitated by submerged recirculating jets.
Kennedy, Stephen; Bhattacharjee, Pradipto K; Bhattacharya, Sati N; Eshtiaghi, Nicky; Parthasarathy, Rajarathinam
2018-01-01
Submerged recirculating jet mixing systems are an efficient and economical method of agitating large tanks with a high hydraulic residence time. Much work has been carried out in developing design correlations to aid the predictions of the mixing time in such systems, with the first such correlation being developed nearly 70 years ago. In most of these correlations, the mixing time depends directly on the volume of the vessel and inversely on the injection velocity of the submerged jet. This work demonstrates, for the first time, that the distance between the injection and suction nozzles also significantly affects the mixing time and can be used to control this time scale. The study introduces a non-dimensional quantity that can be used as an adjustable parameter in systems where such control is desired.
Control of the mixing time in vessels agitated by submerged recirculating jets
Bhattacharjee, Pradipto K.; Bhattacharya, Sati N.; Eshtiaghi, Nicky; Parthasarathy, Rajarathinam
2018-01-01
Submerged recirculating jet mixing systems are an efficient and economical method of agitating large tanks with a high hydraulic residence time. Much work has been carried out in developing design correlations to aid the predictions of the mixing time in such systems, with the first such correlation being developed nearly 70 years ago. In most of these correlations, the mixing time depends directly on the volume of the vessel and inversely on the injection velocity of the submerged jet. This work demonstrates, for the first time, that the distance between the injection and suction nozzles also significantly affects the mixing time and can be used to control this time scale. The study introduces a non-dimensional quantity that can be used as an adjustable parameter in systems where such control is desired. PMID:29410817
Numerical simulation of compressible fluid flow in an ultrasonic suction pump.
Wada, Yuji; Koyama, Daisuke; Nakamura, Kentaro
2016-08-01
Characteristics of an ultrasonic suction pump that uses a vibrating piston surface and a pipe are numerically simulated and compared with experimental results. Fluid analysis based on the finite-difference time-domain (FDTD) routine is performed, where the nonlinear term and the moving fluid-surface boundary condition are considered. As a result, the suction mechanism of the pump is found to be similar to that of a check valve, where the gap is open during the inflow phase, and it is nearly closed during the outflow phase. The effects of Reynolds number, vibration amplitude and gap thickness on the pump performance are analyzed. The calculated result is in good agreement with the previously measured results. Copyright © 2016 Elsevier B.V. All rights reserved.
Combined effects on MHD flow of Newtonian fluid past infinite vertical porous plate
NASA Astrophysics Data System (ADS)
Subbanna, K.; Mohiddin, S. Gouse; Vijaya, R. Bhuvana
2018-05-01
In this paper, we discussed free convective flow of a viscous fluid past an infinite vertical porous plate under the influence of uniform transverse magnetic field. Time dependent permeability and oscillatory suction is considered. The equations of the flow field are solved by a routine perturbation method for small amplitude of the permeability. The solutions for the velocity, temperature and concentration have been derived analytically and also its behavior is computationally discussed with the help of profiles. The shear stress, the Nusselt number and Sherwood number are also obtained and their behavior discussed computationally
Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D
2017-07-01
To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.
Proximal suction tracheotomy tube reduces aspiration volume.
Coffman, Heather M S; Rees, Catherine J; Sievers, Ann E F; Belafsky, Peter C
2008-04-01
Conventional cuffed tracheotomy tubes do not prevent aspiration of secretions. Aspiration of saliva may be decreased with the use of a subglottic suction port. Prospective. Shiley Disposable Cuffed Tracheotomy (DCT) tubes sizes 4, 6, and 8 (Tyco Healthcare, Pleasanton, CA) were compared to Portex Blue Line Ultra Suctionaid (BLUS) tracheotomy tubes sizes 6, 7, and 8 (Fig 1; Smiths Medical, Watford, UK). All tubes were tested in a simulated tracheal model using 10 cc of human saliva with no suction, intermittent suction, and constant suction (15 minutes). There was a significant decrease in aspirate between the larger Shiley and BLUS tubes with intermittent suction (mean 8.38 mL Shiley 6 vs 1.60 mL BLUS 7; 8.50 mL Shiley 8 vs 2.80 mL BLUS 8). There was a significant decrease in aspirate between all sizes of Shiley and BLUS tubes with continuous suction. For BLUS 7 and 8, there was a significant difference between intermittent suction (mean, 1.60 mL, 2.80 mL, respectively) and continuous suction (mean, 0.20 mL, 0.60 mL respectively). Shiley and BLUS without suction were equivalent. Subglottic suction tracheotomy tubes reduce the risk of aspiration beyond the cuff in a bench-top model.
Soil water retention and maximum capillary drive from saturation to oven dryness
Morel-Seytoux, Hubert J.; Nimmo, John R.
1999-01-01
This paper provides an alternative method to describe the water retention curve over a range of water contents from saturation to oven dryness. It makes two modifications to the standard Brooks and Corey [1964] (B-C) description, one at each end of the suction range. One expression proposed by Rossi and Nimmo [1994] is used in the high-suction range to a zero residual water content. (This Rossi-Nimmo modification to the Brooks-Corey model provides a more realistic description of the retention curve at low water contents.) Near zero suction the second modification eliminates the region where there is a change in suction with no change in water content. Tests on seven soil data sets, using three distinct analytical expressions for the high-, medium-, and low-suction ranges, show that the experimental water retention curves are well fitted by this composite procedure. The high-suction range of saturation contributes little to the maximum capillary drive, defined with a good approximation for a soil water and air system as HcM = ∫0∞ Krwdhc , where krw is relative permeability (or conductivity) to water and hc is capillary suction, a positive quantity in unsaturated soils. As a result, the modification suggested to describe the high-suction range does not significantly affect the equivalence between Brooks-Corey (B-C) and van Genuchten [1980] parameters presented earlier. However, the shape of the retention curve near “natural saturation” has a significant impact on the value of the capillary drive. The estimate using the Brooks-Corey power law, extended to zero suction, will exceed that obtained with the new procedure by 25 to 30%. It is not possible to tell which procedure is appropriate. Tests on another data set, for which relative conductivity data are available, support the view of the authors that measurements of a retention curve coupled with a speculative curve of relative permeability as from a capillary model are not sufficient to accurately determine the (maximum) capillary drive. The capillary drive is a dynamic scalar, whereas the retention curve is of a static character. Only measurements of infiltration rates with time can determine the capillary drive with precision for a given soil.
Computations of Flow over a Hump Model Using Higher Order Method with Turbulence Modeling
NASA Technical Reports Server (NTRS)
Balakumar, P.
2005-01-01
Turbulent separated flow over a two-dimensional hump is computed by solving the RANS equations with k - omega (SST) turbulence model for the baseline, steady suction and oscillatory blowing/suction flow control cases. The flow equations and the turbulent model equations are solved using a fifth-order accurate weighted essentially. nonoscillatory (WENO) scheme for space discretization and a third order, total variation diminishing (TVD) Runge-Kutta scheme for time integration. Qualitatively the computed pressure distributions exhibit the same behavior as those observed in the experiments. The computed separation regions are much longer than those observed experimentally. However, the percentage reduction in the separation region in the steady suction case is closer to what was measured in the experiment. The computations did not predict the expected reduction in the separation length in the oscillatory case. The predicted turbulent quantities are two to three times smaller than the measured values pointing towards the deficiencies in the existing turbulent models when they are applied to strong steady/unsteady separated flows.
Reduction of turbomachinery noise
NASA Technical Reports Server (NTRS)
Waitz, Ian A. (Inventor); Hayden, Belva J. (Inventor); Ingard, K. Uno (Inventor); Brookfield, John M. (Inventor); Sell, Julian (Inventor)
1999-01-01
In the invention, propagating broad band and tonal acoustic components of noise characteristic of interaction of a turbomachine blade wake, produced by a turbomachine blade as the blade rotates, with a turbomachine component downstream of the rotating blade, are reduced. This is accomplished by injection of fluid into the blade wake through a port in the rotor blade. The mass flow rate of the fluid injected into the blade wake is selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake. With this fluid injection, reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved. In a further noise reduction technique, boundary layer fluid is suctioned into the turbomachine blade through a suction port on the side of the blade that is characterized as the relatively low-pressure blade side. As with the fluid injection technique, the mass flow rate of the fluid suctioned into the blade is here selected to reduce the momentum deficit of the wake to correspondingly increase the time-mean velocity of the wake and decrease the turbulent velocity fluctuations of the wake; reduction of both propagating broad band and tonal acoustic components of noise produced by interaction of the blade wake with a turbomachine component downstream of the rotating blade is achieved with this suction technique. Blowing and suction techniques are also provided in the invention for reducing noise associated with the wake produced by fluid flow around a stationary blade upstream of a rotating turbomachine.
NASA Astrophysics Data System (ADS)
Reid, M. E.; Iverson, R. M.; Brien, D. L.; Iverson, N. R.; Lahusen, R. G.; Logan, M.
2016-12-01
Shallow landslides and ensuing debris flows can be triggered by diverse hydrologic phenomena such as groundwater inflow, prolonged moderate-intensity precipitation, or bursts of high-intensity precipitation. However, hazard assessments typically rely on simplistic hydrologic models that disregard this diversity. We used the USGS debris-flow flume to conduct controlled, field-scale slope failure experiments designed to investigate the effects of diverse hydrologic pathways, as well as the effects of 3D landslide geometries and suction stresses in unsaturated soil. Using overhead sprinklers or groundwater injectors on the flume bed, we induced failures in 6 m3 (0.65-m thick and 2-m wide) prisms of loamy sand on a 31º slope. We used 50 sensors to monitor soil deformation, variably saturated pore pressures, and moisture changes. We also determined shear strength, hydraulic conductivity, and unsaturated moisture retention characteristics from ancillary tests. The three hydrologic scenarios noted above led to different behaviors. Groundwater injection and prolonged infiltration created differing soil moisture patterns. Intense sprinkling bursts caused rapid failure without development of widespread positive pore pressures. We simulated these observed differences numerically by coupling 2D variably saturated groundwater flow modeling and 3D limit-equilibrium analysis. We also simulated the time evolution of changes in factors of safety, and quantified the mechanical effects of 3D geometry and unsaturated soil suction on stability. When much of the soil became relatively wet, effects of 3D geometry and soil suction produced slight increases ( 10-20%) in factors of safety. Suction effects were more pronounced with drier soils. Our results indicate that simplistic models cannot consistently predict the timing of slope failure, and that high frequency monitoring (with sampling periods < 60 s) is needed to measure and interpret the effects of rapid hydrologic triggers.
Method for maintaining precise suction strip porosities
NASA Technical Reports Server (NTRS)
Gallimore, Frank H. (Inventor)
1989-01-01
This invention relates to a masking method generally and, more particularly to a method of masking perforated titanium sheets having laminar control suction strips. As illustrated in the drawings, a nonaerodynamic surface of a perforated sheet has alternating suction strip areas and bonding land areas. Suction strip tapes overlie the bonding land areas during application of a masking material to an upper surface of the suction strip tapes. Prior to bonding the perforated sheet to a composite structure, the bonding land tapes are removed. The entire opposite aerodynamic surface is masked with tape before bonding. This invention provides a precise control of suction strip porosities by ensuring that no chemicals penetrate the suction strip areas during bonding.
Development of laminar flow control wing surface porous structure
NASA Technical Reports Server (NTRS)
Klotzsche, M.; Pearce, W.; Anderson, C.; Thelander, J.; Boronow, W.; Gallimore, F.; Brown, W.; Matsuo, T.; Christensen, J.; Primavera, G.
1984-01-01
It was concluded that the chordwise air collection method, which actually combines chordwise and spanwise air collection, is the best of the designs conceived up to this time for full chord laminar flow control (LFC). Its shallower ducting improved structural efficiency of the main wing box resulting in a reduction in wing weight, and it provided continuous support of the chordwise panel joints, better matching of suction and clearing airflow requirements, and simplified duct to suction source minifolding. Laminar flow control on both the upper and lower surfaces was previously reduced to LFC suction on the upper surface only, back to 85 percent chord. The study concludes that, in addition to reduced wing area and other practical advantages, this system would be lighter because of the increase in effective structural wing thickness.
Suction-based grasping tool for removal of regular- and irregular-shaped intraocular foreign bodies.
Erlanger, Michael S; Velez-Montoya, Raul; Mackenzie, Douglas; Olson, Jeffrey L
2013-01-01
To describe a suction-based grasping tool for the surgical removal of irregular-shaped and nonferromagnetic intraocular foreign bodies. A surgical tool with suction capabilities, consisting of a stainless steel shaft with a plastic handle and a customizable and interchangeable suction tip, was designed in order to better engage and manipulate irregular-shaped in-traocular foreign bodies of various sizes and physical properties. The maximal suction force and surgical capabilities were assessed in the laboratory and on a cadaveric eye vitrectomy model. The suction force of the water-tight seal between the intraocular foreign body and the suction tip was estimated to be approximately 40 MN. During an open-sky vitrectomy in a porcine model, the device was successful in engaging and firmly securing foreign bodies of different sizes and shapes. The suction-based grasping tool enables removal of irregular-shaped and nonferromagnetic foreign bodies. Copyright 2013, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Hassan, Marwan A.; Ismail, Mohd A. M.
2017-10-01
The point of this review is to depict the impact of various inflow discharge rate releases on the instruments of matric suction and volumetric water content during an experimental test of spatial overtopping failure at school of civil engineering in universiti Sains of Malaysia. A dry sand dike was conducted inside small flume channel with twelve sensors of tensiometer and Time-Domain Reflectometer (TDR). Instruments are installed in the soil at different locations in downstream and upstream slopes of the dike for measuring the response of matric suction and volumetric water content, respectively. Two values of inflow discharge rates of 30 and 40 L/min are utilized as a part of these experiments to simulate the effectiveness of water reservoirs in erosion mechanism. The outcomes demonstrate that the matric suction and volumetric water content are decreased and increased, respectively for both inflow discharges. The higher inflow discharges accelerate the saturation of dike soil and the erosion process faster than that for the lower inflow discharges.
Ultra-fast underwater suction traps.
Vincent, Olivier; Weisskopf, Carmen; Poppinga, Simon; Masselter, Tom; Speck, Thomas; Joyeux, Marc; Quilliet, Catherine; Marmottant, Philippe
2011-10-07
Carnivorous aquatic Utricularia species catch small prey animals using millimetre-sized underwater suction traps, which have fascinated scientists since Darwin's early work on carnivorous plants. Suction takes place after mechanical triggering and is owing to a release of stored elastic energy in the trap body accompanied by a very fast opening and closing of a trapdoor, which otherwise closes the trap entrance watertight. The exceptional trapping speed--far above human visual perception--impeded profound investigations until now. Using high-speed video imaging and special microscopy techniques, we obtained fully time-resolved recordings of the door movement. We found that this unique trapping mechanism conducts suction in less than a millisecond and therefore ranks among the fastest plant movements known. Fluid acceleration reaches very high values, leaving little chance for prey animals to escape. We discovered that the door deformation is morphologically predetermined, and actually performs a buckling/unbuckling process, including a complete trapdoor curvature inversion. This process, which we predict using dynamical simulations and simple theoretical models, is highly reproducible: the traps are autonomously repetitive as they fire spontaneously after 5-20 h and reset actively to their ready-to-catch condition.
Suction evacuation of hemothorax: A prospective study.
Savage, Stephanie A; Cibulas, George A; Ward, Tyler A; Davis, Corinne A; Croce, Martin A; Zarzaur, Ben L
2016-07-01
Although tube thoracostomy is a common procedure after thoracic trauma, incomplete evacuation of fluid places the patient at risk for retained hemothorax. As little as 300 to 500 cm of blood may result in the need for an additional thoracostomy tube or, in more severe cases, lung entrapment and empyema. We hypothesized that suction evacuation of the thoracic cavity before tube placement would decrease the incidence of late complications. Patients requiring tube thoracostomy within 96 hours of admission were prospectively identified and underwent suction evacuation of the pleural space (SEPS) before tube placement. These patients were compared to historical controls without suction evacuation. Demographics, admission vital signs, laboratory values, details of chest tube placement, and outcomes were collected on all patients. Multivariable logistic regression was used to compare outcomes between groups. A total of 199 patients were identified, consisting of 100 retrospective controls and 99 SEPS patients. There were no differences in age, sex, admission injury severity score or chest abbreviated injury score, admission laboratory values or vital signs, or hospital length of stay. Mean (SD) volume of hemothorax in SEPS patients was 220 (297) cm; with only 48% having a volume greater than 100 cm at the time of tube placement. Three patients developed empyema, and 19 demonstrated retained blood; there was no difference between SEPS and control patients. Suction evacuation of the pleural space was significantly protective against recurrent pneumothorax after chest tube removal (odds ratio, 0.332; 95% confidence interval, 0.148-0.745). Preemptive suction evacuation of the thoracic cavity did not have a significant impact on subsequent development of retained hemothorax or empyema. Suction evacuation of the pleural space significantly decreased incidence of recurrent pneumothorax after thoracostomy removal. Although the mechanism is unclear, such a benefit may make this simple procedure worthwhile. A larger sample size is required for validation and to determine if preemptive thoracic evacuation has a clinical benefit. Therapeutic/care management study, level IV.
Kobara, Hideki; Mori, Hirohito; Fujihara, Shintaro; Nishiyama, Noriko; Chiyo, Taiga; Yamada, Takayoshi; Fujiwara, Masao; Okano, Keiichi; Suzuki, Yasuyuki; Murota, Masayuki; Ikeda, Yoshitaka; Oryu, Makoto; AboEllail, Mohamed; Masaki, Tsutomu
2017-01-01
AIM To demonstrate the clinical outcomes of a multicenter experience and to suggest guidelines for choosing a suction method. METHODS This retrospective study at 5 medical centers involved 58 consecutive patients undergoing over-the-scope clips (OTSCs) placement. The overall rates of technical success (TSR), clinical success (CSR), complications, and procedure time were analyzed as major outcomes. Subsequently, 56 patients, excluding two cases that used the Anchor device, were divided into two groups: 14 cases of simple suction (SS-group) and 42 cases using the Twin Grasper (TG-group). Secondary evaluation was performed to clarify the predictors of OTSC success. RESULTS The TSR, CSR, complication rate, and median procedure time were 89.7%, 84.5%, 1.8%, and 8 (range 1-36) min, respectively, demonstrating good outcomes. However, significant differences were observed between the two groups in terms of the mean procedure time (5.9 min vs 14.1 min). The CSR of the SS- and TG-groups among cases with a maximum defect size ≤ 10 mm and immediate or acute refractory bleeding was 100%, which suggests that SS is a better method than TG in terms of time efficacy. The CSR in the SS-group (78.6%), despite the technical success of the SS method (TSR, 100%), tended to decrease due to delayed leakage compared to that in the TG-group (TSR, CSR; 88.1%), indicating that TG may be desirable for leaks and fistulae with defects of the entire layer. CONCLUSION OTSC system is a safe and effective therapeutic option for gastrointestinal defects. Individualized selection of the suction method based on particular clinical conditions may contribute to the improvement of OTSC success. PMID:28321166
Magnesium sulfate micro air pump suction for bronchiolitis treatment in infants under two years old.
Kan, R-X; Zhang, C-L; Zhen, Q; Chen, J
2016-01-01
To investigate the efficiency, clinical effects and nursing methods related to the use of magnesium sulfate micro air pump suction for treating infants under two years old suffering from bronchiolitis. From January 2014 to September 2014, ninety-six infants with capillary bronchitis were enrolled. Patients were randomly divided into two groups: experimental group (n=49) and control group (n=47). All patients went through conventional anti-inflammatory therapy. Based on this, infants in the control group were additionally treated with intravenous drip of magnesium sulfate while patients in the experimental group were treated with magnesium sulfate micro air pump suction. We recorded all changes in blood gas and clinical scores, the residence time of symptoms and signs of bronchiolitis, and hospitalization time. Results obtained on clinical effects and adverse reactions were compared and analyzed. The Variations of PaO2, PaCO2, SaO2 before treatment in both groups did not show any statistically significant differences (p>0.05); while after treatment analyses demonstrated that in both groups we had an increase in PaO2 and SaO2 and a decrease in PaCO2. The increase in PaO2 and SaO2 values were more pronounced while the decrease observed in PaCO2 was more significant in our experimental group. The total effective rate was significantly higher while the total adverse reaction rate, the resolution time of clinical symptoms and hospitalization time were significantly lower in our experimental group. Magnesium sulfate micro air pump suction was safe and effective in treating with bronchiolitis of infants below 2 years old, and its adverse reaction rate was low, nursing procedure was simple, and nursing difficulty level was low.
Gupta, Diksha; Singh, Bani
2014-01-01
The objective of this investigation is to analyze the effect of unsteadiness on the mixed convection boundary layer flow of micropolar fluid over a permeable shrinking sheet in the presence of viscous dissipation. At the sheet a variable distribution of suction is assumed. The unsteadiness in the flow and temperature fields is caused by the time dependence of the shrinking velocity and surface temperature. With the aid of similarity transformations, the governing partial differential equations are transformed into a set of nonlinear ordinary differential equations, which are solved numerically, using variational finite element method. The influence of important physical parameters, namely, suction parameter, unsteadiness parameter, buoyancy parameter and Eckert number on the velocity, microrotation, and temperature functions is investigated and analyzed with the help of their graphical representations. Additionally skin friction and the rate of heat transfer have also been computed. Under special conditions, an exact solution for the flow velocity is compared with the numerical results obtained by finite element method. An excellent agreement is observed for the two sets of solutions. Furthermore, to verify the convergence of numerical results, calculations are conducted with increasing number of elements. PMID:24672310
NASA Astrophysics Data System (ADS)
Dauenhauer, Eric C.; Majdalani, Joseph
2003-06-01
This article describes a self-similarity solution of the Navier-Stokes equations for a laminar, incompressible, and time-dependent flow that develops within a channel possessing permeable, moving walls. The case considered here pertains to a channel that exhibits either injection or suction across two opposing porous walls while undergoing uniform expansion or contraction. Instances of direct application include the modeling of pulsating diaphragms, sweat cooling or heating, isotope separation, filtration, paper manufacturing, irrigation, and the grain regression during solid propellant combustion. To start, the stream function and the vorticity equation are used in concert to yield a partial differential equation that lends itself to a similarity transformation. Following this similarity transformation, the original problem is reduced to solving a fourth-order differential equation in one similarity variable η that combines both space and time dimensions. Since two of the four auxiliary conditions are of the boundary value type, a numerical solution becomes dependent upon two initial guesses. In order to achieve convergence, the governing equation is first transformed into a function of three variables: The two guesses and η. At the outset, a suitable numerical algorithm is applied by solving the resulting set of twelve first-order ordinary differential equations with two unspecified start-up conditions. In seeking the two unknown initial guesses, the rapidly converging inverse Jacobian method is applied in an iterative fashion. Numerical results are later used to ascertain a deeper understanding of the flow character. The numerical scheme enables us to extend the solution range to physical settings not considered in previous studies. Moreover, the numerical approach broadens the scope to cover both suction and injection cases occurring with simultaneous wall motion.
NASA Technical Reports Server (NTRS)
Pfenninger, W.; Syberg, J.
1974-01-01
The feasibility of quiet, suction laminarized, high Reynolds number (Re) supersonic wind tunnel nozzles was studied. According to nozzle wall boundary layer development and stability studies, relatively weak area suction can prevent amplified nozzle wall TS (Tollmien-Schlichting) boundary layer oscillations. Stronger suction is needed in and shortly upstream of the supersonic concave curvature nozzle area to avoid transition due to amplified TG (Taylor-Goertler) vortices. To control TG instability, moderately rapid and slow expansion nozzles require smaller total suction rates than rapid expansion nozzles, at the cost of larger nozzle length Re and increased TS disturbances. Test section mean flow irregularities can be minimized with suction through longitudinal or highly swept slots (swept behind local Mach cone) as well as finely perforated surfaces. Longitudinal slot suction is optimized when the suction-induced crossflow velocity increases linearly with surface distance from the slot attachment line toward the slot (through suitable slot geometry). Suction in supersonic blowdown tunnels may be operated by one or several individual vacuum spheres.
Dental equipment test during zero-gravity flight
NASA Technical Reports Server (NTRS)
Young, John; Gosbee, John; Billica, Roger
1991-01-01
The overall objectives of this program were to establish performance criteria and develop prototype equipment for use in the Health Maintenance Facility (HMF) in meeting the needs of dental emergencies during space missions. The primary efforts during this flight test were to test patient-operator relationships, patent (manikin) restraint and positioning, task lighting systems, use and operation of dental rotary instruments, suction and particle containment system, dental hand instrument delivery and control procedures, and the use of dental treatment materials. The initial efforts during the flight focused on verification of the efficiency of the particle containment system. An absorptive barrier was also tested in lieu of the suction collector. To test the instrument delivery system, teeth in the manikin were prepared with the dental drill to receive restorations, some with temporary filling materials and another with definitive filling material (composite resin). The best particle containment came from the combination use of the laminar-air/suction collector in concert with immediate area suction from a surgical high-volume suction tip. Lighting in the treatment area was provided by a flexible fiberoptic probe. This system is quite effective for small areas, but for general tasks ambient illumination is required. The instrument containment system (elastic cord network) was extremely effective and easy to use. The most serious problem with instrument delivey and actual treatment was lack of time during the microgravity sequences. The restorative materials handled and finished well.
Wagh, Mihir S; Montane, Roberto
2012-02-01
The upper GI tract and the colon are readily accessible endoscopically, but the small intestine is relatively difficult to evaluate. To demonstrate the feasibility of using suction as a means of locomotion and to assess the initial design of a suction enteroscope. Feasibility study. Animal laboratory. Various prototype suction devices designed in our laboratory were tested in swine small intestine in a force test station. For in vivo experiments in live anesthetized animals, two suction devices (1 fixed tip and 1 movable tip) were attached to the outside of the endoscope. By creating suction in the fixed tip, the endoscope was anchored while the movable tip was advanced. Suction was then applied to the extended tip to attach it to the distal bowel. Suction on the fixed tip was then released and the movable tip with suction pulled back, resulting in advancement of the endoscope. These steps were sequentially repeated. Intestinal segments were sent for pathologic assessment after testing. Force generated ranged from 0.278 to 4.74 N with 64.3 to 88 kPa vacuum pressure. A linear relationship was seen between the pull force and vacuum pressures and tip surface area. During in vivo experiments, the endoscope was advanced in 25-cm segmental increments with sequential suction-and-release maneuvers. No significant bowel trauma was seen on pathology and necropsy. The enteroscopy system requires further refinement. A novel suction enteroscope was designed and tested. Suction tip characteristics played a critical role impacting the functionality of this enteroscopy system. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Taheri, Parvin; Asgari, Narges; Mohammadizadeh, Majid; Golchin, Mehri
2012-01-01
Aims: Mechanical ventilation is used for some infants in neonatal intensive care units (NICU) due to many physiological and clinical causes. Since these patients have endotracheal tubes, cleaning and keeping the airways open through suctioning should be done to increase oxygenation. This study aimed to evaluate effect of open and closed suctioning methods on respiratory parameters of infants undergoing mechanical ventilation. Materials and Methods: In this crossover clinical trial, 44 infants were selected among those undergone mechanical ventilation in NICU of Isfahan's Al-Zahra Hospital using convenience sampling method. The subjects were randomly divided into two groups. In the first group, open suctioning was carried out and after three hours of cleaning, closed suctioning was done. In the second group, closed suctioning was firstly done and following three hours of cleaning, open suctioning was implemented. Respiratory rate (RR) and percentage of arterial blood oxygen saturation was measured before, during and after each type of suctioning. Data were analyzed using repeated measures ANOVA and independent student's t-test. Findings: There was a significant difference between mean respiratory rate and arterial blood oxygen saturation in infants before, during and after the closed and open suctioning. The percentage of arterial blood oxygen saturation had a significant reduction in open method compared to closed method during suctioning and immediately after it. RR three minutes after suctioning showed a significant reduction in both steps in open method compared to closed method. Conclusions: Close method caused fewer changes in hemodynamic status of infants. Therefore, in order to prevent respiratory complications in infants, nurses are recommended to perform the endotracheal tube suctioning by closed method. PMID:23493041
Gocyk, Wojciech; Kużdżał, Jarosław; Włodarczyk, Janusz; Grochowski, Zbigniew; Gil, Tomasz; Warmus, Janusz; Kocoń, Piotr; Talar, Piotr; Obarski, Piotr; Trybalski, Łukasz
2016-10-01
Sufficiently large, prospective randomized trials comparing suction drainage and nonsuction drainage are lacking. The aim of the present study was to compare the effects of suction drainage and nonsuction drainage on the postoperative course in patients who have undergone lung resection. This prospective, randomized trial included patients undergoing different types of lung resections. On the day of surgery, suction drainage at -20 cm H2O was used. On the morning of the first postoperative day, patients, in whom the pulmonary parenchyma was fully reexpanded, were randomized in the ratio of 1:1. Patients assigned to group A continued with suction drainage, while those assigned to group B underwent nonsuction drainage. The study included 254 patients, with 127 patients in each group. The drainage volumes were 1098.8 mL and 814.4 mL in groups A and B, respectively (p = 0.0014). The times to chest tube removal were 5.61 days and 4.49 days in groups A and B, respectively (p = 0.0014). Prolonged air leakage occurred in 5.55% of patients in group A and in 0.7% of patients in group B (p = 0.032), and asymptomatic residual air spaces were noted in 0.8% of patients in group A and 9.4% of patients in group B (p = 0.0018). Nonsuction drainage is more effective than suction drainage with regard to drainage volume, drainage duration, and incidence of persistent air leakage. However, it is associated with a higher incidence of asymptomatic residual air spaces. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Suresh Babu, Arun Vishnu; Ramesh, Kiran; Gopalarathnam, Ashok
2017-11-01
In previous research, Ramesh et al. (JFM,2014) developed a low-order discrete vortex method for modeling unsteady airfoil flows with intermittent leading edge vortex (LEV) shedding using a leading edge suction parameter (LESP). LEV shedding is initiated using discrete vortices (DVs) whenever the Leading Edge Suction Parameter (LESP) exceeds a critical value. In subsequent research, the method was successfully employed by Ramesh et al. (JFS, 2015) to predict aeroelastic limit-cycle oscillations in airfoil flows dominated by intermittent LEV shedding. When applied to flows that require large number of time steps, the computational cost increases due to the increasing vortex count. In this research, we apply an amalgamation strategy to actively control the DV count, and thereby reduce simulation time. A pair each of LEVs and TEVs are amalgamated at every time step. The ideal pairs for amalgamation are identified based on the requirement that the flowfield in the vicinity of the airfoil is least affected (Spalart, 1988). Instead of placing the amalgamated vortex at the centroid, we place it at an optimal location to ensure that the leading-edge suction and the airfoil bound circulation are conserved. Results of the initial study are promising.
Sound levels in conservative dentistry and endodontics clinic
Dutta, Arindam; Mala, Kundabala; Acharya, Shashi Rashmi
2013-01-01
Aim: To evaluate the sound levels generated in dental clinics of conservative dentistry and endodontics. Material and Methods: A decibel-meter with digital readout was used to measure sound levels at different time intervals at the chairside and at the center of the clinic. Minimum and maximum readings during a 3 min interval were recorded. Results: In the post-graduate (PG) clinic, there was significant difference in noise levels between the chairside (66-81 dB[A]) and the center of the clinic (66-67 dB[A]) at certain times. In the under graduate (UG) clinic, noise levels with suction and either high/slow speed handpieces (67-80 dB[A]) were significantly higher than the center of clinic. Suction alone in the UG clinic (63-75 dB[A]) was significantly quieter than in the PG clinic (69-79 dB[A]). Conclusions: (1) Mean sound levels in the working clinics ranged from 63.0 dB[A] to 81.5 dB[A]. These are within the recommended range for dental equipment. (2) With suction and either low/high speed handpiece combination, the PG clinic was significantly noisier than the UG clinic at several time periods. PMID:23716962
Develop a consumer-style report for currently available suction pump devices on the market . List parameters such as suction flow rate, pressure...evaluate whether suction devices that are currently on the market meet these requirements.
Interpretation of in situ tests as affected by soil suction.
DOT National Transportation Integrated Search
2013-07-01
Soil moisture conditions are subject to change depending on the season in which they are tested. In : unsaturated soils the moisture at which a soil is tested can directly affect strength and stiffness of the : material. In situ testing is commonly u...
Chintamani; Singhal, Vinay; Singh, JP; Bansal, Anju; Saxena, Sunita
2005-01-01
Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology) proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound) in to 50 patients with full vacuum suction (pressure = 700 g/m2) and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2) groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons) using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results Half vacuum suction drains were removed earlier than the full suction vacuum suction drains. There was no significant difference in the incidence of seroma formation in the two groups and there was a significant reduction in the total hospital stay in patients with half vacuum suction drainage systems as compared to the full suction drainage group (p < 0.001) without any added morbidity. Conclusions Half negative suction drains provide an effective compromise between no suction and full or high suction drainage after modified radical mastectomy by reducing the hospital stay and the post operative morbidity including post operative seromas. PMID:15676064
Optimum Suction Distribution for Transition Control
NASA Technical Reports Server (NTRS)
Balakumar, P.; Hall, P.
1996-01-01
The optimum suction distribution which gives the longest laminar region for a given total suction is computed. The goal here is to provide the designer with a method to find the best suction distribution subject to some overall constraint applied to the suction. We formulate the problem using the Lagrangian multiplier method with constraints. The resulting non-linear system of equations is solved using the Newton-Raphson technique. The computations are performed for a Blasius boundary layer on a flat-plate and crossflow cases. For the Blasius boundary layer, the optimum suction distribution peaks upstream of the maximum growth rate region and remains flat in the middle before it decreases to zero at the end of the transition point. For the stationary and travelling crossflow instability, the optimum suction peaks upstream of the maximum growth rate region and decreases gradually to zero.
Ventrain: an ejector ventilator for emergency use.
Hamaekers, A E W; Borg, P A J; Enk, D
2012-06-01
A small, flow-regulated, manually operated ventilator designed for ventilation through a narrow-bore transtracheal catheter (TTC) has become available (Ventrain, Dolphys Medical BV, Eindhoven, The Netherlands). It is driven by a predetermined flow of oxygen from a high-pressure source and facilitates expiration by suction. The aim of this bench study was to test the efficacy of this new ventilator. The driving pressure, generated insufflation, and suction pressures and also the suction capacity of the Ventrain were measured at different oxygen flows. The minute volume achieved in an artificial lung through a TTC with an inner diameter (ID) of 2 mm was determined at different settings. Oxygen flows of 6-15 litre min(-1) resulted in driving pressures of 0.5-2.3 bar. Insufflation pressures, measured proximal to the TTC, ranged from 23 to 138 cm H(2)O. The maximal subatmospheric pressure build-up was -217 cm H(2)O. The suction capacity increased to a maximum of 12.4 litre min(-1) at an oxygen flow of 15 litre min(-1). At this flow, the achievable minute volume through the TTC ranged from 5.9 to 7.1 litres depending on the compliance of the artificial lung. The results of this bench study suggest that the Ventrain is capable of achieving a normal minute volume for an average adult through a 2 mm ID TTC. Further in vivo studies are needed to determine the value of the Ventrain as a portable emergency ventilator in a 'cannot intubate, cannot ventilate' situation.
21 CFR 880.5740 - Suction snakebite kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...
21 CFR 880.5740 - Suction snakebite kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...
21 CFR 880.5740 - Suction snakebite kit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...
21 CFR 880.5740 - Suction snakebite kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...
21 CFR 880.5740 - Suction snakebite kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
... Suction Apparatus Device Intended for Negative Pressure Wound Therapy AGENCY: Food and Drug Administration...- powered suction apparatus device intended for negative pressure wound therapy (NPWT) into class II... ``Class II Special Controls Guidance Document: Non-Powered Suction Apparatus Device Intended for Negative...
21 CFR 870.5050 - Patient care suction apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Patient care suction apparatus. 870.5050 Section 870.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suction apparatus. (a) Identification. A patient care suction apparatus is a device used with an...
21 CFR 870.5050 - Patient care suction apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Patient care suction apparatus. 870.5050 Section 870.5050 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suction apparatus. (a) Identification. A patient care suction apparatus is a device used with an...
21 CFR 878.4780 - Powered suction pump.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered suction pump. 878.4780 Section 878.4780...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4780 Powered suction pump. (a) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be...
21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...
21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...
21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Non-Powered suction apparatus device intended for... Surgical Devices § 878.4683 Non-Powered suction apparatus device intended for negative pressure wound therapy. (a) Identification. A non-powered suction apparatus device intended for negative pressure wound...
Matar, Eman M; Arabiat, Diana H; Foster, Mandie J
2016-11-01
This research was undertaken with the purpose of testing two research hypotheses regarding the efficacy of 10% oral glucose solution on procedural pain associated with venepuncture and nasopharyngeal suctioning within three neonatal intensive care units (NICU). The hypotheses were formulated from previous conclusions reached by other researchers highlighting the efficacy of sucrose solutions on neonates' pain responses during minor painful procedures. A quasi-experimental trial utilising a time series design with one group was used. Data from a total of 90 neonates included 60 neonates who underwent a venepuncture and 30 neonates who underwent a nasopharyngeal suctioning procedure for clinical purposes. The neonate's pain response for each procedure was scored using the Neonatal Pain Assessment Scale (NPAS) on two separate occasions over three time periods. The pre-procedural score (T 0 ) when the neonate received no sucrose, the inter-procedural score (T 1 ) when the neonate was given 2ml of 10% glucose solution two minutes before the procedure (intervention group) or where oral glucose was withheld (control group) and the post-procedural score (T 2 ) being at the end of the procedure. The results showed the mean NPAS scores in response to venepuncture or nasopharyngeal suctioning were significantly lower in the intervention group than the control group. This showed that oral glucose (10%) had a positive effect on the pain response during venepuncture and nasopharyngeal suctioning procedures. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bobbitt, Percy J.; Ferris, James C.; Harvey, William D.; Goradia, Suresh H.
1992-01-01
A description is given of the development of, and results from, the hybrid laminar flow control (HLFC) experiment conducted in the NASA LaRC 8 ft Transonic Pressure Tunnel on a 7 ft chord, 23 deg swept model. The methods/codes used to obtain the contours of the HLFC model surface and to define the suction requirements are outlined followed by a discussion of the model construction, suction system, instrumentation, and some example results from the wind tunnel tests. Included in the latter are the effects of Mach number, suction level, and the extent of suction. An assessment is also given of the effect of the wind tunnel environment on the suction requirements. The data show that, at or near the design Mach number, large extents of laminar flow can be achieved with suction mass flows over the first 25 percent, or less, of the chord. Top surface drag coefficients with suction extending from the near leading edge to 20 percent of the chord were approximately 40 percent lower than those obtained with no suction. The results indicate that HLFC can be designed for transonic speeds with lift and drag coefficients approaching those of LFC designs but with much smaller extents and levels of suction.
NASA Astrophysics Data System (ADS)
Kucera, Florian; Beisser, Christian J.; Lemell, Patrick
2018-03-01
Many studies have yet been conducted on suction feeding in aquatic salamander species. Within the Salamandridae, the crested newt Triturus dobrogicus (Kiritzescu, 1903), occurring from the Austrian Danube floodplains to the Danube Delta, was not subject of investigations so far. The present study examines the kinematics of aquatic suction feeding in this species by means of high-speed videography. Recordings of five individuals of different size and sex while feeding on bloodworms were conducted, in order to identify potential discrepancies among individuals and sizes. Five coordinate points were digitized from recordings of prey capture and twelve time- and velocity-determined variables were evaluated. All specimens follow a typical inertial suction feeding process, where rapid hyoid depression expands the buccal cavity. Generated negative pressure within the buccal cavity causes influx of water along with the prey item into the mouth. Results demonstrate higher distance values and angles for gape in individuals with smaller size. In addition, hyoid depression is maximized in smaller individuals. While Triturus dobrogicus resembles a typical inertial suction feeder in its functional morphology, intraspecific differences could be found regarding the correlation of different feeding patterns and body size.
Motta, Philip J; Hueter, Robert E; Tricas, Timothy C; Summers, Adam P; Huber, Daniel R; Lowry, Dayv; Mara, Kyle R; Matott, Michael P; Whitenack, Lisa B; Wintzer, Alpa P
2008-09-01
The nurse shark, Ginglymostoma cirratum, is an obligate suction feeder that preys on benthic invertebrates and fish. Its cranial morphology exhibits a suite of structural and functional modifications that facilitate this mode of prey capture. During suction-feeding, subambient pressure is generated by the ventral expansion of the hyoid apparatus and the floor of its buccopharyngeal cavity. As in suction-feeding bony fishes, the nurse shark exhibits expansive, compressive, and recovery kinematic phases that produce posterior-directed water flow through the buccopharyngeal cavity. However, there is generally neither a preparatory phase nor cranial elevation. Suction is generated by the rapid depression of the buccopharyngeal floor by the coracoarcualis, coracohyoideus, and coracobranchiales muscles. Because the hyoid arch of G. cirratum is loosely connected to the mandible, contraction of the rectus cervicis muscle group can greatly depress the floor of the buccopharyngeal cavity below the depressed mandible, resulting in large volumetric expansion. Suction pressures in the nurse shark vary greatly, but include the greatest subambient pressures reported for an aquatic-feeding vertebrate. Maximum suction pressure does not appear to be related to shark size, but is correlated with the rate of buccopharyngeal expansion. As in suction-feeding bony fishes, suction in the nurse shark is only effective within approximately 3 cm in front of the mouth. The foraging behavior of this shark is most likely constrained to ambushing or stalking due to the exponential decay of effective suction in front of the mouth. Prey capture may be facilitated by foraging within reef confines and close to the substrate, which can enhance the effective suction distance, or by foraging at night when it can more closely approach prey.
Bousarri, Mitra Payami; Shirvani, Yadolah; Agha-Hassan-Kashani, Saeed; Nasab, Nouredin Mousavi
2014-05-01
In patients undergoing mechanical ventilation, mucus production and secretion is high as a result of the endotracheal tube. Because endotracheal suction in these patients is essential, chest physiotherapy techniques such as expiratory rib cage compression before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretion and improving alveolar ventilation. As one of the complications of mechanical ventilation and endotracheal suctioning is decrease of cardiac output, this study was carried out to determine the effect of expiratory rib cage compression before endotracheal suctioning on the vital signs in patients under mechanical ventilation. This study was a randomized clinical trial with a crossover design. The study subjects included 50 mechanically ventilated patients, hospitalized in intensive care wards of Valiasr and Mousavi hospitals in Zanjan, Iran. Subjects were selected by consecutive sampling and randomly allocated to groups 1 and 2. The patients received endotracheal suctioning with or without rib cage compression, with a minimum of 3 h interval between the two interventions. Expiratory rib cage compression was performed for 5 min before endotracheal suctioning. Vital signs were measured 5 min before and 15 and 25 min after endotracheal suctioning. Data were recorded on a data recording sheet. Data were analyzed using paired t-tests. There were statistically significant differences in the means of vital signs measured 5 min before with 15 and 25 min after endotracheal suctioning with rib cage compression (P < 0. 01). There was no significant difference in the means of diastolic pressure measured 25 min after with baseline in this stage). But on the reverse mode, there was a significant difference between the means of pulse and respiratory rate 15 min after endotracheal suctioning and the baseline values (P < 0.002). This effect continued up to 25 min after endotracheal suctioning just for respiratory rate (P = 0.016). Moreover, there were statistically significant differences in the means of vital signs measured 5 min before and 15 min after endotracheal suctioning between the two methods (P ≤ 0001). Findings showed that expiratory rib cage compression before endotracheal suctioning improves the vital signs to normal range in patients under mechanical ventilation. More studies are suggested on performing expiratory rib cage compression before endotracheal suctioning in patients undergoing mechanical ventilation.
Ridge suction drives plume-ridge interactions
NASA Astrophysics Data System (ADS)
Niu, Y.; Hékinian, R.
2003-04-01
Deep-sourced mantle plumes, if existing, are genetically independent of plate tectonics. When the ascending plumes approach lithospheric plates, interactions between the two occur. Such interactions are most prominent near ocean ridges where the lithosphere is thin and the effect of plumes is best revealed. While ocean ridges are mostly passive features in terms of plate tectonics, they play an active role in the context of plume-ridge interactions. This active role is a ridge suction force that drives asthenospheric mantle flow towards ridges because of material needs to form the ocean crust at ridges and lithospheric mantle in the vicinity of ridges. This ridge suction force increases with increasing plate separation rate because of increased material demand per unit time. As the seismic low-velocity zone atop the asthenosphere has the lowest viscosity that increases rapidly with depth, the ridge-ward asthenospheric flow is largely horizontal beneath the lithosphere. Recognizing that plume materials have two components with easily-melted dikes/veins enriched in volatiles and incompatible elements dispersed in the more refractory and depleted peridotitic matrix, geochemistry of some seafloor volcanics well illustrates that plume-ridge interactions are consequences of ridge-suction-driven flow of plume materials, which melt by decompression because of lithospheric thinning towards ridges. There are excellent examples: 1. The decreasing La/Sm and increasing MgO and CaO/Al_2O_3 in Easter Seamount lavas from Salas-y-Gomez Islands to the Easter Microplate East rift zone result from progressive decompression melting of ridge-ward flowing plume materials. 2. The similar geochemical observations in lavas along the Foundation hotline towards the Pacific-Antarctic Ridge result from the same process. 3. The increasing ridge suction force with increasing spreading rate explains why the Iceland plume has asymmetric effects on its neighboring ridges: both topographic and geochemical anomalies extend < 400 km along the slower (20 to 13 mm/yr northward) spreading South Kolbeinsey Ridge, but > 1500 km along the faster (20 to 25 mm/yr southward) spreading Reykjanes Ridge. 4. The spreading-rate dependent ridge suction force also explains the first-order differences between the fast-spreading East Pacific Rise (EPR) and the slow-spreading Mid-Atlantic Ridge (MAR). Identified mantle plumes/hotspots are abundant near the MAR (e.g., Iceland, Azores, Ascension, Tristan, Gough, Shona and Bouvet), but rare along the entire EPR (notably, the Easter hotspot at ˜27^oS on the Nazca plate). Such apparent unequal hotspot distribution would allow a prediction of more enriched MORB at the MAR than at the EPR. However, the mean compositions between MAR-MORB and EPR-MORB are the same in terms of incompatible element abundances, and are identical in terms of Sr-Nd-Pb isotopic ratios. This suggests similar extents of mantle plume contributions to EPR and MAR MORB. We consider that the apparent rarity of near-EPR plumes/hotspots results from fast spreading. The fast spreading creates large ridge suction forces that do not allow the development of surface expressions of mantle plumes as such, but draw plume materials to a broad zone of sub-ridge upwelling, giving rise to random distribution of abundant enriched MORB and elevated and smooth axial topography along the EPR (vs. MAR). One of the important implications is that the asthenospheric flow is necessarily decoupled from its overlaying oceanic lithospheric plate. This decoupling increases with increasing spreading rate.
Sun, Fengbo; Wang, He; Zhang, Fengjuan; Zhang, Xinming; Xing, Zhiyuan; Zhang, Shenglin; Zhang, Haifeng; Wang, Ye
2017-05-09
The objective of this study was to determine whether copious irrigation of peritoneal cavity during laparoscopic appendectomy for complicated appendicitis effectively reduces the incidence of postoperative complications and improves the postoperative recovery in adults compared with suction alone. In this prospective randomized trial, adult patients with complicated appendicitis were randomized to "irrigation and suction"(IS) group or "suction only"(SO) group. All surgery was performed with a standardized 3-port laparoscopic approach. The IS group received peritoneal irrigation with a minimum of 2000 mL sterile normal saline. The study primary outcomes included wound infection and postoperative intra-abdominal abscess. The study secondary outcomes included duration of operation, first anal exsufflation time, duration of hospital stay and hospital charges. Chi-squared and t-tests were used to analyze the study data. Between January 2015 and June 2016, a total of 260 patients with complicated appendicitis were enrolled in the study. The peritoneal irrigation resulted in a longer operation time (51.6 ± 16.1 vs. 41.5 ± 15.2 min, p <0.001). There was no significant difference in the rate of wound infection between the two groups. However, the patients who received irrigation had a lower postoperative intra-abdominal abscess rate (3.1% vs. 9.2%, p = 0.039), earlier anal exsufflation (25.2 ± 16.5 vs. 30.7 ± 18.1 hr, p = 0.011), shorter hospital stay (10.2 ± 2.5 vs. 12.5 ± 2.8 days, p <0.001) and lower hospital charges (¥14,592 ± 2,251 vs. 16,674 ± 2,163, p <0.001) compared to those received suction alone. The study findings revealed that copious irrigation of peritoneal cavity during laparoscopic appendectomy could decrease the incidence of postoperative intra-abdominal abscess in adult patients with complicated appendicitis. These patients also had faster postoperative recovery and lower hospital charges.
Closing the loop of the soil water retention curve
Lu, Ning; Alsherif, N; Wayllace, Alexandra; Godt, Jonathan W.
2015-01-01
The authors, to their knowledge for the first time, produced two complete principal soil water retention curves (SWRCs) under both positive and negative matric suction regimes. An innovative testing technique combining the transient water release and imbibition method (TRIM) and constant flow method (CFM) was used to identify the principal paths of SWRC in the positive pore-water pressure regime under unsaturated conditions. A negative matric suction of 9.8 kPa is needed to reach full saturation or close the loop of the SWRC for a silty soil. This work pushes the understanding of the interaction of soil and water into new territory by quantifying the boundaries of the SWRC over the entire suction domain, including both wetting and drying conditions that are relevant to field conditions such as slope wetting under heavy rainfall or rapid groundwater table rise in earthen dams or levees.
NASA Astrophysics Data System (ADS)
Chiorean, Vasile-Florin
2017-10-01
Matric suction is a soil parameter which influences the behaviour of unsaturated soils in both terms of shear strength and permeability. It is a necessary aspect to know the variation of matric suction in unsaturated soil zone for solving geotechnical issues like unsaturated soil slopes stability or bearing capacity for unsaturated foundation ground. Mathematical expression of the dependency between soil moisture content and it’s matric suction (soil water characteristic curve) has a powerful character of nonlinearity. This paper presents two methods to determine the variation of matric suction along the depth included between groundwater level and soil level. First method is an analytical approach to emphasize one direction steady state unsaturated infiltration phenomenon that occurs between the groundwater level and the soil level. There were simulated three different situations in terms of border conditions: precipitations (inflow conditions on ground surface), evaporation (outflow conditions on ground surface), and perfect equilibrium (no flow on ground surface). Numerical method is finite element method used for steady state, two-dimensional, unsaturated infiltration calculus. Regarding boundary conditions there were simulated identical situations as in analytical approach. For both methods, was adopted the equation proposed by van Genuchten-Mualen (1980) for mathematical expression of soil water characteristic curve. Also for the unsaturated soil permeability prediction model was adopted the equation proposed by van Genuchten-Mualen. The fitting parameters of these models were adopted according to RETC 6.02 software in function of soil type. The analyses were performed in both methods for three major soil types: clay, silt and sand. For each soil type were concluded analyses for three situations in terms of border conditions applied on soil surface: inflow, outflow, and no flow. The obtained results are presented in order to highlight the differences/similarities between the methods and the advantages / disadvantages of each one.
Davis, Anne R; Horvath, Sarah K; Castaño, Paula M
2017-03-01
Screening for fetal aneuploidy has evolved over the past 2 decades. Whether these advances impact gestational age at abortion has received little study. We sought to describe trends in the gestational age at the time of abortion by fetal diagnosis over an 11-year study period. We hypothesized that gestational age at time of abortion would decrease for fetal aneuploidy but remain unchanged for structural abnormalities. We conducted a retrospective case series of all women undergoing surgical abortion for fetal aneuploidy or structural abnormalities up to 24 weeks' gestation from 2004 through 2014 in a hospital operating room setting at a single, urban medical center. We excluded labor induction abortions (<1% of abortions at our medical center) and suction aspirations performed in the office practice. We performed suction aspiration up to 14 weeks and dilation and evacuation after that gestational age. We describe the median gestational age at abortion by fetal indication and year. For women undergoing abortion for fetal aneuploidy (n = 392), the median gestational age at time of abortion decreased from 19.0 weeks (interquartile range 18.0-21.0) in 2004 to 14.0 weeks (interquartile range 13.0-17.0) in 2014 (Kruskal-Wallis P < .0001). For women undergoing abortion for fetal structural abnormalities (n = 586), the median gestational age was ≥20 weeks for each year during the study interval (P = .1). As gestational age decreased in the fetal aneuploidy group, fewer women underwent dilation and evacuation and more became eligible for suction aspiration (<14 weeks). In 2004, >90% of women underwent dilation and evacuation for either indication. By 2014, 31% of women with fetal aneuploidy were eligible for suction aspiration compared to 11% of those with structural anomalies. Gestational age at the time of abortion for fetal aneuploidy decreased substantially from 2004 through 2014; earlier abortion is safer for women. In contrast, women seeking abortion for fetal structural abnormalities did not experience a change in timing. Legislation restricting gestational age at the time of abortion could disproportionately affect women with fetal structural abnormalities. Copyright © 2016 Elsevier Inc. All rights reserved.
Stöcklmayer, C; Dorffner, G; Schmidt, C; Schima, H
1995-07-01
Rotary blood pumps are used in clinical applications to assist circulation via pumping blood from the left atrium to the aorta. Negative inflow pressures at high flow rates can cause suction of the cannula in the left atrium with deleterious effects on the atrial wall, the blood, and the lung. Therefore, stable and reliable detection of suction and the prediction of the left atrium pressure (LAP) would be of major interest for the control of these pumps. This work reports about an in vitro study of such a detector based on artificial neural networks (ANN). In the first project phase, an ANN was used to estimate the LAP based on pump speed, pump flow, and aortic pressure, obtained from a mock circulation. The inputs for the ANN were 11 characteristic values computed from these three parameters. In the second phase, another ANN was trained to classify various system states, such as suction, danger of suction (a state close to actual suction), and no suction. The first ANN was able to estimate the LAP with an accuracy of +/- 1.8 mm Hg. The discrimination of suction versus the other two states could be performed with a sensitivity and specificity of about 95% while the more interesting task of distinguishing danger of suction from no suction reached a sensitivity and specificity of about 65% (leaving 25% of each class unclassified and 10% of each class incorrectly classified).(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Technical Reports Server (NTRS)
1996-01-01
The Burg Corporation needed to get more power out of the suction system in their Vac 'N Bag grass mower/litter remover. The president submitted a problem statement to the Marshall Space Flight Center Technology Transfer Office, which devised a way to guide heavier items of trash to a point where suction was greatest, and made changes to the impeller and the exhaust port, based on rocket propulsion technology. The improved system is used by highway departments, city governments and park authorities, reducing work time by combining the tasks of grass cutting and vacuuming trash and grass clippings.
Mamoun, John S
2011-01-01
When assisting a dentist, an assistant may need to hold the high volume evacuation (HVE) attachment and use it to suction aerosols produced by the dentist's tools, particularly the high speed hand piece or the cavitron. The main objective of suctioning is to hold the inlet of the HVE attachment close enough to the source of aerosols to evacuate those aerosols, while avoiding suctioning of the patient's intra-oral soft tissues, and avoiding contact of the HVE attachment with the hand piece, cavitron or other instrument that the dentist is using. In general, assisting a dentist with suctioning is a somewhat complex skill that may require months of experience before an assistant develops an intuition for suctioning. This is the first part of a two-part article. The first part describes the basic concepts and clinical techniques that an assistant should be conscious of in order to be able to properly assist a dentist in performing evacuation tasks, describes retraction techniques for use while suctioning, and describes use of the saliva ejector and surgical suction attachment.
Chang, John S M; Law, Antony K P; Ng, Jack C M; Cheng, May S Y
2017-01-01
To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK.
Chang, John S.M.; Law, Antony K.P.; Ng, Jack C.M.; Cheng, May S.Y.
2017-01-01
Purpose To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). Methods All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. Results In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Conclusion Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK. PMID:28690535
NASA Technical Reports Server (NTRS)
Nikkanen, J. P.; Brooky, J. P.
1972-01-01
A single-stage compressor with a rotor tip speed of 1600 ft/sec and a 0.5 hub tip ratio was used to investigate the effects of several stator endwall treatment methods on stage range and performance. These endwall treatment methods consisted of stator corner-blow, annular wall suction upstream of stator leading edge, and combined corner-blow and annular wall suction. The overall stage performance with corner blow was essentially the same as the baseline performance. The performance for the annular wall suction and the combined corner-blow and wall suction showed a reduction in peak efficiency of 2.5 percentage points compared to the baseline data.
NASA Technical Reports Server (NTRS)
1999-01-01
This document describes the design of the leading edge suction system for flight demonstration of hybrid laminar flow control on the Boeing 757 airplane. The exterior pressures on the wing surface and the required suction quantity and distribution were determined in previous work. A system consisting of porous skin, sub-surface spanwise passages ("flutes"), pressure regulating screens and valves, collection fittings, ducts and a turbocompressor was defined to provide the required suction flow. Provisions were also made for flexible control of suction distribution and quantity for HLFC research purposes. Analysis methods for determining pressure drops and flow for transpiration heating for thermal anti-icing are defined. The control scheme used to observe and modulate suction distribution in flight is described.
Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito
2017-01-01
With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1-28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.
Passive control of a biventricular assist device with compliant inflow cannulae.
Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel
2012-08-01
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Feeding Kinematics, Suction, and Hydraulic Jetting Performance of Harbor Seals (Phoca vitulina)
Marshall, Christopher D.; Wieskotten, Sven; Hanke, Wolf; Hanke, Frederike D.; Marsh, Alyssa; Kot, Brian; Dehnhardt, Guido
2014-01-01
The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina) were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01) than biting feeding events (0.18±0.08 s). Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events) compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land). Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001) and gape angle (12.9±2.02°), pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm) and gape angle (28.8±1.80°; P<0.001) and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their opportunistic, generalized feeding ecology and concomitant breadth of diet. PMID:24475170
Feeding kinematics, suction, and hydraulic jetting performance of harbor seals (Phoca vitulina).
Marshall, Christopher D; Wieskotten, Sven; Hanke, Wolf; Hanke, Frederike D; Marsh, Alyssa; Kot, Brian; Dehnhardt, Guido
2014-01-01
The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina) were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01) than biting feeding events (0.18±0.08 s). Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events) compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land). Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001) and gape angle (12.9±2.02°), pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm) and gape angle (28.8±1.80°; P<0.001) and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their opportunistic, generalized feeding ecology and concomitant breadth of diet.
The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
Frengley, R W; Closey, D N; Sleigh, J W; Torrance, J M
2001-12-01
To measure airway pressures during closed system suctioning with the ventilator set to three differing modes of ventilation. Closed system suctioning was conducted in 16 patients following cardiac surgery. Suctioning was performed using a 14 French catheter with a vacuum level of -500 cmH2O through an 8.0 mm internal diameter endotracheal tube. The lungs were mechanically ventilated with a Servo 300 ventilator set to one of three ventilation modes: volume-control, pressure-control or CPAP/pressure support. Airway pressures were measured via a 4 French electronic pressure transducer in both proximal and distal airways. Following insertion of the suction catheter, end-expiratory pressure increased significantly (p < 0.001) in both pressure-control and volume-control ventilation. This increase was greatest (p = 0.018) in volume-control mode (2.7 +/- 1.7 cmH2O). On performing a five second suction, airway pressure decreased in all modes, however the lowest airway pressure in volume-control mode (-4.9 +/- 4.0 cmH2O) was significantly (p = 0.001) less than the lowest airway pressure recorded in either pressure-control (0.8 +/- 1.9 cmH2O) or CPAP/pressure support (0.4 +/- 2.8 cmH2O) modes. In CPAP/pressure support mode, 13 of the 16 patients experienced a positive pressure 'breath' at the end of suctioning with airway pressures rising to 21 +/- 1.6 cmH2O. Closed system suctioning in volume control ventilation may result in elevations of end-expiratory pressure following catheter insertion and subatmospheric airway pressures during suctioning. Pressure control ventilation produces less elevation of end-expiratory pressure following catheter insertion and is less likely to be associated with subatmospheric airway pressures during suctioning. CPAP/pressure support has no effect on end-expiratory pressure following catheter insertion and subatmospheric airway pressures are largely avoided during suctioning.
In situ control of cardiotomy suction reduces blood trauma.
Tevaearai, H T; Mueller, X M; Horisberger, J; Augstburger, M; Bock, H; Knorr, A; von Segesser, L K
1998-01-01
Cardiotomy suction is known for its deleterious effects on formed and unformed blood elements. The authors investigated an "intelligent" remote controlled automatic suction system. A suction cannula with an optic sensor at its tip was connected to a special closed cardiotomy reservoir. Contact with blood immediately generated a reservoir vacuum from 0 to -100 mmHg, permitting aspiration until the blood was no longer detected (automatic shut off). Blood trauma was evaluated in a bovine model, comparing the automatic suction system vs standard continuous aspiration (control) adjusted to -100 mmHg. After full systemic heparinization, five calves (weight, 62.5 +/- 4.4 kg) for the automatic suction system group, and four (weight, 62.8 +/- 5.1 kg) for the control group, were equipped with a jugular cannula connected via a roller pump to the cardiotomy reservoir. Through a small thoracotomy, a standardized hole was created in the right atrium, allowing for a blood loss of approximately 400 ml/min. The suction cannula was placed into the chest cavity in a fixed position. Blood samples were drawn at regular intervals for cell count and chemistry. Lactate dehydrogenase values, for the automatic suction system and the control groups, respectively, expressed as percent of baseline value, were 88 +/- 14 vs 116 +/- 22 after 1 hr; 94 +/- 16 vs 123 +/- 23 after 2 hr; and 97 +/- 19 vs 140 +/- 48 after 3 hr (p < 0.05). Values for free hemoglobin in plasma (percent of baseline value), for the automatic suction system and the control groups, respectively, were 102 +/- 18 vs 200 +/- 69 after 1 hr; 98 +/- 29 vs 163 +/- 37 after 2 hr; and 94 +/- 37 vs 179 +/- 42 after 3 hr (p < 0.05). Compared with a standard continuous aspiration system, in situ regulation of suction significantly reduces blood trauma.
Costa, Gabriel Cerqueira Alves; Soares, Adriana Coelho; Pereira, Marcos Horácio; Gontijo, Nelder Figueiredo; Sant'Anna, Maurício Roberto Viana; Araujo, Ricardo Nascimento
2016-11-15
Ornithodoros rostratus is an argasid tick and its importance is based on its hematophagy and the resulting transmission of pathogens such as Rickettsia rickettsii and Coxiella burnetii to its vertebrate hosts. In the face of a lack of physiological studies related to hematophagy in argasid ticks, this paper aims to identify and characterize the events that occur throughout the feeding by O. rostratus on live hosts. Electrical signals and alterations on the feeding site were monitored using intravital microscopy and electromyography. The analyses allowed for the characterization of four distinct events: suction, salivation, chelicerae movements and inactivity. Feeding was divided into two distinct phases: (1) penetration of mouthparts (when only salivation and chelicerae movements occurred) and the formation of the feeding pool (salivation and chelicerae movements with the first signs of suction) and (2) engorgement, during which chelicerae movements ceased and blood intake took place in feeding complexes (salivation followed by suction). Variations in patterns of the electrical signals, suction frequency and salivation showed four distinct sub-phases: (2a) suction with electrical signals of irregular shape, increased suction frequency and decreased salivation frequency throughout blood feeding; (2b) suction with electrical signals of symmetrical shape, high suction rates (3.8 Hz on average) and feeding complexes lasting for 7.7 s; (2c) suction with electrical signals of irregular shape, high suction frequency and feeding complex lasting 11.5 s; and (2d) electrical signals with no profile and the longest feeding complexes (14.5 s). Blood feeding ended with the withdrawal of the mouthparts from the host's skin. © 2016. Published by The Company of Biologists Ltd.
Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M
2010-09-01
Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.
Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue
2017-08-01
Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.
Wall Climbing Micro Ground Vehicle (MGV)
2013-09-01
magnetic attraction, (2) vacuum suction, (3) bio-mimetic techniques such as gecko pads, and (4) adhesion forces generated by aerodynamic principles, also...large attractive forces, but are limited to ferrous surfaces. Vacuum suction, such as in suction cups, also has the ability to create large adhesion...clean. Vortex adhesion does not require a perfect seal like vacuum suction and has the ability to travel over porous surfaces such as brick and
Vacuum-actuated percutaneous insertion/implantation tool for flexible neural probes and interfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Heeral; Bennett, William J.; Pannu, Satinderpall S.
A flexible device insertion tool including an elongated stiffener with one or more suction ports, and a vacuum connector for interfacing the stiffener to a vacuum source, for attaching the flexible device such as a flexible neural probe to the stiffener during insertion by a suction force exerted through the suction ports to, and to release the flexible device by removing the suction force.
Belcaro, G; Rulo, A; Renton, S
1992-01-01
To evaluate capillary filtration a group of normal subjects and two groups of subjects with venous incompetence (50 with deep and 50 with superficial incompetence) were studied with the vacuum suction chamber (VSC) device applied onto the internal perimalleolar region. This method was compared with straingauge plethysmography rate of ankle swelling (RAS). By the VSC the time taken for the weal to disappear (VSC time) was considered indicative of capillary filtration. The values obtained with the two methods were well related (r < 0.742) and there was a good separation between patients and normals. The separation between the two groups of patients was significantly better (p < 0.05) with the VSC time. In conclusion VSC time is a good indication of capillary filtration in comparison with straingauge plethysmography RAS. It may be used to assess variations in capillary filtration in venous hypertension and possibly to follow up the effects of treatments.
Catheter drainage of spontaneous pneumothorax: suction or no suction, early or late removal?
So, S Y; Yu, D Y
1982-01-01
Twenty-three patients with primary spontaneous pneumothorax and 30 patients with secondary spontaneous pneumothorax treated by intercostal catheter drainage with underwater seal were divided randomly into two groups, one receiving suction drainage (up to 20 cm H2O pressure) and the other no suction. The success rate was 57% for the former and 50% for the latter. The suction group spent an average of five days in hospital, whereas the non-suction group averaged four days. Suction drainage therefore did not have any advantage. To determine how soon the catheter could be removed without complication, patients were also divided randomly into two subgroups--one had the catheter removed, without previous clamping, as soon as the lung was expanded; the other had the catheters left in situ for a further three days. The success rate was 52% for the former, and 53% for the latter. But most of the failure in the early removal group was caused by re-collapse of the lung rather than persistent air leakage; hence removal of the catheter too early was not recommended. PMID:7071793
VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A
2014-01-01
In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.
Audit of Endotracheal Tube Suction in a Pediatric Intensive Care Unit.
Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne
2017-02-01
We report outcomes of a clinical audit examining criteria used in clinical practice to rationalize endotracheal tube (ETT) suction, and the extent these matched criteria in the Endotracheal Suction Assessment Tool(ESAT)©. A retrospective audit of patient notes ( N = 292) and analyses of criteria documented by pediatric intensive care nurses to rationalize ETT suction were undertaken. The median number of documented respiratory and ventilation status criteria per ETT suction event that matched the ESAT© criteria was 2 [Interquartile Range (IQR) 1-6]. All criteria listed within the ESAT© were documented within the reviewed notes. A direct link was established between criteria used for current clinical practice of ETT suction and the ESAT©. The ESAT©, therefore, reflects documented clinical decision making and could be used as both a clinical and educational guide for inexperienced pediatric critical care nurses. Modification to the ESAT © requires "preparation for extubation" to be added.
Control of water and nutrients using a porous tube - A method for growing plants in space
NASA Technical Reports Server (NTRS)
Dreschel, Thomas W.; Sager, John C.
1989-01-01
A plant nutrient delivery system that uses a microporous, hydrophilic tube was developed with potential application for crop production in the microgravity of space. The tube contains a nutrient solution and delivers it to the roots. Pumps attached to the tubing create a very small suction that holds the solution within the tube. This system was used to grow wheat for 107 d in a controlled environment at suctions of 0.40, 1.48, or 2.58 kPa. The water absorbed through the pores of the tube by baby diaper sections decreased as suction increased. Correspondingly, final plant biomass, seed number, and spikelet number also tended to decrease as suction increased. The reduced yield at higher suction suggests that the plants experienced water stress, although all suctions were below those typical of soils at field capacity.
Methods and systems to enhance flame holding in a gas turbine engine
Zuo, Baifang [Simpsonville, SC; Lacy, Benjamin Paul [Greer, SC; Stevenson, Christian Xavier [Inman, SC
2012-01-31
A fuel nozzle including a swirler assembly that includes a shroud, a hub, and a plurality of vanes extending between the shroud and the hub. Each vane includes a pressure sidewall and an opposite suction sidewall coupled to the pressure sidewall at a leading edge and at a trailing edge. At least one suction side fuel injection orifice is formed adjacent to the leading edge and extends from a first fuel supply passage to the suction sidewall. A fuel injection angle is oriented with respect to the suction sidewall. The suction side fuel injection orifice is configured to discharge fuel outward from the suction sidewall. At least one pressure side fuel injection orifice extends from a second fuel supply passage to the pressure sidewall and is substantially parallel to the trailing edge. The pressure side fuel injection orifice is configured to discharge fuel tangentially from the trailing edge.
Effect of suction on the mechanical characteristics of uniformly compacted rammed earth
NASA Astrophysics Data System (ADS)
El Hajjar, A.; Chauhan, P.; Prime, N.; Plé, O.
2018-04-01
Rammed earth, in the current environmental situation, is an alternative construction technique which can help in reducing energy and raw material consumption owing to its “sustainable” characteristics. To fully understand its behavior and properties, recent scientific investigations consider it as a compacted unsaturated material with suction as its one of the main sources of strength. Eathern constructions face, over their lifetime, variations in the suction state which have a significant impact on their mechanical characteristics. In the present contribution, unconfined compression tests are performed, with and without unload-reload cycles, on homogeneously compacted samples subjected to various suction conditions. This study shows that both the unconfined compressive strength and Young modulus reduce with the reduction of suction states. Suction also seems to influence the amount of plastic strains and damage phenomenon. Indeed, the soils analyzed are slightly active and shows both plasticity behavior and damage phenomenon.
NASA Technical Reports Server (NTRS)
Brooks, Cuyler W., Jr.; Harris, Charles D.; Harvey, William D.
1991-01-01
A swept supercritical wing incorporating laminar flow control at transonic flow conditions was designed and tested. The definition of an experimental suction coefficient and a derivation of the compressible and incompressible formulas for the computation of the coefficient from measurable quantities is presented. The suction flow coefficient in the highest velocity nozzles is shown to be overpredicted by as much as 12 percent through the use of an incompressible formula. However, the overprediction on the computed value of suction drag when some of the suction nozzles were operating in the compressible flow regime is evaluated and found to be at most 6 percent at design conditions.
Calculation of vortex lift effect for cambered wings by the suction analogy
NASA Technical Reports Server (NTRS)
Lan, C. E.; Chang, J. F.
1981-01-01
An improved version of Woodward's chord plane aerodynamic panel method for subsonic and supersonic flow is developed for cambered wings exhibiting edge separated vortex flow, including those with leading edge vortex flaps. The exact relation between leading edge thrust and suction force in potential flow is derived. Instead of assuming the rotated suction force to be normal to wing surface at the leading edge, new orientation for the rotated suction force is determined through consideration of the momentum principle. The supersonic suction analogy method is improved by using an effective angle of attack defined through a semi-empirical method. Comparisons of predicted results with available data in subsonic and supersonic flow are presented.
An application of the suction analog for the analysis of asymmetric flow situations
NASA Technical Reports Server (NTRS)
Luckring, J. M.
1976-01-01
A recent extension of the suction analogy for estimation of vortex loads on asymmetric configurations is reviewed. This extension includes asymmetric augmented vortex lift and the forward sweep effect on side edge suction. Application of this extension to a series of skewed wings has resulted in an improved estimating capability for a wide range of asymmetric flow situations. Hence, the suction analogy concept now has more general applicability for subsonic lifting surface analysis.
Preliminary study of efficacy of cup suction in the correction of typical pectus excavatum.
Lopez, Manuel; Patoir, Arnaud; Costes, Frederic; Varlet, François; Barthelemy, Jean-Claude; Tiffet, Olivier
2016-01-01
This preliminary qualitative study evaluates the efficacy of cup suction in the correction of pectus excavatum (PE), and examines the place of this system as a strategic treatment and as an alternative to surgery. Between October 2011 and June 2014, a total of 84 patients (children and adult) presenting with PE were treated by cup suction, in our chest wall deformities unit. On first consultation, the patients with typical PE and with at least partial correction during the first application of cup suction and a maximal suction pressure for correction of less than 300 mbar (millibars) were included in this study. 11 patients were excluded from the present study as they presented with a complex carinatum/excavatum. The remaining 73 patients were divided into two groups: Group I, adult patients ≥ 18 year old, 17 patients. The mean age was 22.8 years old. Group II, pediatric patients <18 years old, 56 patients. The mean age was 11.5 years old. Medical photographic documentation was collected systematically. In addition, the depth of PE was measured. The management protocol involved: adjustment of cup suction, strengthening exercises, and clinical follow-up every two to three months. The evaluation criteria during, and on the completion of the trial were: depth of the PE, morbidity and treatment compliance. Partial and final results were evaluated by the patients, their parents, and doctor, using a qualitative scoring scale. A total of 73 patients presenting typical PE (symmetric in 52 cases and asymmetric in 21 cases) were treated by cup suction. The mean depth of PE was 23 mm (9-44). Of the 73 patients, one adult abandoned treatment and three children abandoned follow-up. The mean time of use of the device was 4h daily. At six months of treatment, the mean depth of PE was 9 mm (0-30) across all patients. 23 patients completed the treatment and exhibited flattening of the sternum. These patients were considered to have an excellent aesthetic result. The mean treatment duration to normal reshape was achieved at 10 months (4-21). The remaining patients are improving under continuing active treatment. The mean depth of PE in this group was 12 mm (4-30), after a mean treatment duration of 9 months (2-22). Treatment using cup suction is a promising useful alternative in selected cases of symmetric and asymmetric PE, providing that the thorax is flexible. Treatment duration is directly linked to age, severity and the frequency of use. It is becoming a well-recognized therapy, which improves the self-image of those patients whose anterior chest wall is still pliable. The cup suction can be used for pediatrics and young adults waiting for a treatment, possibly surgery, however, the long-term effect of this procedure remains unclear. Copyright © 2016 Elsevier Inc. All rights reserved.
Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Azuma, Takeshi; Itoh, Yoshito
2017-01-01
Backgrounds With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). Methods In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. Results The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p < 0.001, vacuum amount: 38.0 versus 14.0, p < 0.01). Additionally, the water jet function of the BT-S was not inferior. In 39 colorectal ESD cases in two institutions, there were mean 4.7 times (range: 1–28) of knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Conclusions Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results. PMID:29081793
On-demand control of microfluidic flow via capillary-tuned solenoid microvalve suction.
Zhang, Qiang; Zhang, Peiran; Su, Yetian; Mou, Chunbo; Zhou, Teng; Yang, Menglong; Xu, Jian; Ma, Bo
2014-12-21
A simple, low-cost and on-demand microfluidic flow controlling platform was developed based on a unique capillary-tuned solenoid microvalve suction effect without any outer pressure source. The suction effect was innovatively employed as a stable and controllable driving force for the manipulation of the microfluidic system by connecting a piece of capillary between the microvalve and the microfluidic chip, which caused significant hydrodynamic resistance differences among the solenoid valve ports and changed the flowing mode inside the valve. The volume of sucked liquid could be controlled from microliters even down to picoliters either by decreasing the valve energized duration (from a maximum energized duration to the valve response time of 20 ms) or by increasing the inserted capillary length (i.e., its hydrodynamic resistance). Several important microfluidic unit operations such as cell/droplet sorting and on-demand size-controllable droplet generation have been demonstrated on the developed platform and both simulations and experiments confirmed that this platform has good controllability and stability.
Heated air humidification versus cold air nebulization in newly tracheostomized patients.
Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich
2017-12-01
After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.
Heated air humidification versus cold air nebulization in newly tracheostomized patients
Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A.; Sommer, J. Ulrich
2017-01-01
Abstract Background After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold‐air nebulization versus heated high‐flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Methods Newly tracheostomized patients (n = 20) were treated either with cold‐air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. Results The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold‐air nebulization group (3.99 ± 1.39 Hz). Conclusion The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. PMID:28990261
Assessment of capillary suction time (CST) test methodologies.
Sawalha, O; Scholz, M
2007-12-01
The capillary suction time (CST) test is a commonly used method to measure the filterability and the easiness of removing moisture from slurry and sludge in numerous environmental and industrial applications. This study assessed several novel alterations of both the test methodology and the current standard capillary suction time (CST) apparatus. Twelve different papers including the standard Whatman No. 17 chromatographic paper were tested. The tests were run using four different types of sludge including a synthetic sludge, which was specifically developed for benchmarking purposes. The standard apparatus was altered by the introduction of a novel rectangular funnel instead of a standard circular one. A stirrer was also introduced to solve the problem of test inconsistency (e.g. high CST variability) particularly for heavy types of sludge. Results showed that several alternative papers, which are cheaper than the standard paper, can be used to estimate CST values accurately, and that the test repeatability can be improved in many cases and for different types of sludge. The introduction of the rectangular funnel demonstrated an obvious enhancement of test repeatability. The use of a stirrer to avoid sedimentation of heavy sludge did not have statistically significant impact on the CST values or the corresponding data variability. The application of synthetic sludge can support the testing of experimental methodologies and should be used for subsequent benchmarking purposes.
Wertsén, Madeleine; Stenberg, Manne
2017-10-01
The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.
NASA Technical Reports Server (NTRS)
Schobeiri, M. T.; Ozturk, B.; Ashpis, David E.
2007-01-01
The paper experimentally studies the effects of periodic unsteady wake flow and different Reynolds numbers on boundary layer development, separation and re-attachment along the suction surface of a low pressure turbine blade. The experimental investigations were performed on a large scale, subsonic unsteady turbine cascade research facility at Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. The experiments were carried out at Reynolds numbers of 110,000 and 150,000 (based on suction surface length and exit velocity). One steady and two different unsteady inlet flow conditions with the corresponding passing frequencies, wake velocities, and turbulence intensities were investigated. The reduced frequencies chosen cover the operating range of LP turbines. In addition to the unsteady boundary layer measurements, surface pressure measurements were performed. The inception, onset, and the extent of the separation bubble information collected from the pressure measurements were compared with the hot wire measurements. The results presented in ensemble-averaged, and the contour plot forms help to understand the physics of the separation phenomenon under periodic unsteady wake flow and different Reynolds number. It was found that the suction surface displayed a strong separation bubble for these three different reduced frequencies. For each condition, the locations defining the separation bubble were determined carefully analyzing and examining the pressure and mean velocity profile data. The location of the boundary layer separation was dependent of the Reynolds number. It is observed that starting point of the separation bubble and the re-attachment point move further downstream by increasing Reynolds number from 110,000 to 150,000. Also, the size of the separation bubble is smaller when compared to that for Re=110,000.
NASA Technical Reports Server (NTRS)
Ozturk, B.; Schobeiri, M. T.; Ashpis, David E.
2005-01-01
The paper experimentally studies the effects of periodic unsteady wake flow and different Reynolds numbers on boundary layer development, separation and re-attachment along the suction surface of a low pressure turbine blade. The experimental investigations were performed on a large scale, subsonic unsteady turbine cascade research facility at Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. The experiments were carried out at Reynolds numbers of 110,000 and 150,000 (based on suction surface length and exit velocity). One steady and two different unsteady inlet flow conditions with the corresponding passing frequencies, wake velocities, and turbulence intensities were investigated. The reduced frequencies chosen cover the operating range of LP turbines. In addition to the unsteady boundary layer measurements, surface pressure measurements were performed. The inception, onset, and the extent of the separation bubble information collected from the pressure measurements were compared with the hot wire measurements. The results presented in ensemble-averaged, and the contour plot forms help to understand the physics of the separation phenomenon under periodic unsteady wake flow and different Reynolds number. It was found that the suction surface displayed a strong separation bubble for these three different reduced frequencies. For each condition, the locations defining the separation bubble were determined carefully analyzing and examining the pressure and mean velocity profile data. The location of the boundary layer separation was dependent of the Reynolds number. It is observed that starting point of the separation bubble and the re-attachment point move further downstream by increasing Reynolds number from 110,000 to 150,000. Also, the size of the separation bubble is smaller when compared to that for Re=110,000.
Ristau, Neil; Siden, Gunnar Leif
2015-07-21
An airfoil includes a leading edge, a trailing edge downstream from the leading edge, a pressure surface between the leading and trailing edges, and a suction surface between the leading and trailing edges and opposite the pressure surface. A first convex section on the suction surface decreases in curvature downstream from the leading edge, and a throat on the suction surface is downstream from the first convex section. A second convex section is on the suction surface downstream from the throat, and a first convex segment of the second convex section increases in curvature.
Design and Control of a Mechatronic Tracheostomy Tube for Automated Tracheal Suctioning.
Do, Thanh Nho; Seah, Tian En Timothy; Phee, Soo Jay
2016-06-01
Mechanical ventilation is required to aid patients with breathing difficulty to breathe more comfortably. A tracheostomy tube inserted through an opening in the patient neck into the trachea is connected to a ventilator for suctioning. Currently, nurses spend millions of person-hours yearly to perform this task. To save significant person-hours, an automated mechatronic tracheostomy system is needed. This system allows for relieving nurses and other carers from the millions of person-hours spent yearly on tracheal suctioning. In addition, it will result in huge healthcare cost savings. We introduce a novel mechatronic tracheostomy system including the development of a long suction catheter, automatic suctioning mechanisms, and relevant control approaches to perform tracheal suctioning automatically. To stop the catheter at a desired position, two approaches are introduced: 1) Based on the known travel length of the catheter tip; 2) Based on a new sensing device integrated at the catheter tip. It is known that backlash nonlinearity between the suction catheter and its conduit as well as in the gear system of the actuator are unavoidable. They cause difficulties to control the exact position of the catheter tip. For the former case, we develop an approximate model of backlash and a direct inverse scheme to enhance the system performances. The scheme does not require any complex inversions of the backlash model and allows easy implementations. For the latter case, a new sensing device integrated into the suction catheter tip is developed and backlash compensation controls are avoided. Automated suctioning validations are successfully carried out on the proposed experimental system. Comparisons and discussions are also introduced. The results demonstrate a significant contribution and potential benefits to the mechanical ventilation areas.
Tani, A; Saito, T; Kitaya, Y; Takahashi, H; Goto, E
2000-06-01
For suction of water from a water supply vessel including both water and air under microgravity and g-jitter conditions, a water suction system using hydrophilic fibrous cloth was developed and its performance was evaluated at 0.01-0.02 g-realized for 20 s by parabolic flight in an aircraft. Vessels used for the experiment were glass flasks and had a suction port for suction filtration. A piece of hydrophilic fibrous cloth was arranged along the inner surface of the vessels and the end was fixed to the suction port of the vessels. In vessel without hydrophilic cloths and containing 220 mL of water, the water did not move more than 5 mm along the inner surface and did not reach the suction port under low gravity. When hydrophilic cloths were used, on the other hand, water gathered onto the cloth surface, moved up along the cloth and reached the suction port under low gravity. The amount of water sucked from vessels varied with the amount of water in the vessel and the sectional area of hydrophilic cloths. When the vessels including both water and air were flown during parabolic flight (10(-4) g), water in the vessel moved along the cloth and a water film was formed on the cloth. These results indicated that it is possible to suck water using the fibrous cloth suction system under low gravity and microgravity conditions. Under low gravity conditions, it was difficult to suck water only. However, it is not necessary to separate water from air when the system is used for supplying water to plant root medium consisting of both liquid and gas phases.
Tomita, Taketeru; Sato, Keiichi; Suda, Kenta; Kawauchi, Junro; Nakaya, Kazuhiro
2011-05-01
Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computed tomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavior, is also correlated with the second moment of area of the ceratohyal. Considering that large bending stresses are expected to be applied to the ceratohyal cartilage during suction, the larger second moment of area of the ceratohyal of suction-feeding sharks can be interpreted as an adaptation for suction feeding. Based on the small second moment of area of the ceratohyal cartilage of the megamouth shark, the feeding mode of the megamouth shark is considered to be ram feeding, similar to the planktivorous basking shark. From these results, an evolutionary scenario of feeding mechanics of three species of planktivorous sharks can be suggested. In this scenario, the planktivorous whale shark evolved ram feeding from a benthic suction-feeding ancestor. Ram feeding in the planktivorous megamouth shark and the basking shark evolved from ram feeding swimming-type ancestors and that both developed their unique filtering system to capture small-sized prey. Copyright © 2011 Wiley-Liss, Inc.
Effect of Propellant Feed System Coupling and Hydraulic Parameters on Analysis of Chugging
NASA Technical Reports Server (NTRS)
Wood, Don J.; Dorsch, Robert G.
1967-01-01
A digital distributed parameter model was used to study the effects of propellant-feed- system coupling and various hydraulic parameters on the analytical prediction of chugging instabilities. Coupling between the combustion chamber and feed system was controlled by varying the compliance of the injector-dome region. The coupling with the feed system above the pump was varied by changing the amount of cavitation compliance at the pump inlet. The stability limits and chugging frequencies proved to be strongly dependent on the degree of feed-system coupling. The maximum stability condition occurred with intermediate coupling. Under conditions of a high degree of feed-system-combustor coupling, the stability limits and chugging frequencies were primarily dependent on the feed-system characteristics; the responses were characterized by beating patterns. For the system analyzed, the pump suction line had little effect on the stability limits or chugging frequencies. Beating, present under the condition of near zero injector -dome compliance, was eliminated when the suction line was decoupled by employing a sufficiently high value of pump-inlet compliance. Under conditions of maximum feed-system coupling, the magnitude and distribution of line losses in the discharge line had a significant effect on the stability limits but had negligible effect on the chugging frequency and beating characteristics. Also, the length of the discharge line greatly affected the stability limits, chugging frequency, and beating characteristics. The length of the suction line, however, had little effect on the stability limits and chugging frequency but did influence the beating pattern. A resistive-shunt device attached to the pump discharge line to suppress chugging was investigated. The analysis showed that the device was effective under conditions of high feed-system coupling.
de Assumpção, Maíra Seabra; Gonçalves, Renata Maba; Krygierowicz, Lúcia Cristina; Orlando, Ana Cristina T.; Schivinski, Camila Isabel S.
2013-01-01
OBJECTIVE: To evaluate the impact of manual vibrocompression and nasotracheal suctioning on heart (hr) and respiratory (rr) rates, peripheral oxygen saturation (SpO2), pain and respiratory distress in infants in the postoperative period of a cardiac surgery. METHODS: Randomized controlled trial, in which the assessments were performed by the same physiotherapist in two moments: before and after the procedure. The infants were randomly divided into two groups: Intervention (IG), with manual chest vibrocompression, nasotracheal suctioning and resting; and Control CG), with 30 minutes of rest. Cardiorespiratory data (SpO2; hr; rr) were monitored and the following scales were used: Neonatal Infant Pain Scale (NIPS), for pain evaluation, and Bulletin of Silverman-Andersen (BSA), for respiratory distress assessment. The data were verified by analysis of variance (ANOVA) for repeated measures, being significant p<0.05. RESULTS: 20 infants with heart disease, ten in each group (seven acyanotic and three cyanotic) were enrolled, with ages ranging from zero to 12 months. In the analysis of the interaction between group and time, there was a significant difference in the variation of SpO2 (p=0.016), without changes in the other variables. Considering the main effect on time, only rr showed a significant difference (p=0.001). As for the group main effect, there were no statistical differences (SpO2 - p=0.77, hr - p=0.14, rr - p=0.17, NIPS - p=0.49 and BSA - p=0.51 ). CONCLUSIONS: The manual vibrocompression and the nasotracheal suctioning applied to infants in postoperative of cardiac surgery did not altered SpO2 and rr, and did not trigger pain and respiratory distress. [Brazilian Registry of Clinical Trials (ReBEC): REQ: 1467]. PMID:24473957
Babalola, O.; Boersma, L.; Youngberg, C. T.
1968-01-01
Rates of photosynthesis, respiration, and transpiration of Monterey pine (Pinus radiata D. Don) were measured under controlled conditions of soil water suction and soil temperature. Air temperature, relative humidity, light intensity, and air movement were maintained constant. Rates of net photosynthesis, respiration, and transpiration decreased with increasing soil water suction. The decrease in the rates of net photosynthesis and transpiration as a function of the soil temperature at low soil water suctions may be attributed to changes in the viscosity of water. At soil water suctions larger than 0.70 bars rates of transpiration and net photosynthesis may be affected in the same proportion by changes in stomatal apertures. Images PMID:16656800
21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...
21 CFR 870.4430 - Cardiopulmonary bypass intracardiac suction control.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cardiopulmonary bypass intracardiac suction control. 870.4430 Section 870.4430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4430 Cardiopulmonary bypass intracardiac suction control. (a) Identification. A cardiopulmonary bypass...
NASA Technical Reports Server (NTRS)
Cox, William M.; Brown, Christopher S.; Dreschel, Thomas W.
1994-01-01
Placing nutrient solution under suction increases growth. Foam plug seals growing stem of plant, making it possible to maintain suction in nutrient liquid around roots. Jar wrapped in black tape to keep out light. Potential use in terrestrial applications in arid climates or in labor-intensive agricultural situations.
Michailidis, Lucia; Kotsanas, Despina; Orr, Elizabeth; Coombes, Georgia; Bergin, Shan; Haines, Terry; Williams, Cylie
2016-12-01
Low-frequency ultrasonic debridement (LFUD) is a technology that uses sound waves conducted through saline mist to debride wound tissue. Whilst this technology purportedly reduces wound-healing times, the airborne mist generated is potentially problematic. Theoretically, the saline mist could carry an increased number of microbes into the surrounding environment, posing an infection control risk to the patient, clinician, and clinical environment. This research aimed to establish the degree and extent to which there is microbial spread during the use of, and following the use of, LFUD. The total number of colony forming units was identified for use of LFUD without the suction attachment (control) and with the suction attachment (intervention). This was a prospective, observational study with repeated measures across each treatment (before, during, and after). Quota sampling in a 2 × 2 × 2 factorial design was undertaken so that half of the 24 treatments were conducted at each health service (Monash Health vs Peninsula Health), in different treatment environments (inpatient vs outpatient), and half were conducted with and without suction. The use of suction was not randomized but was determined at the treating clinician's discretion. Patients treated in the inpatient environment lay on their beds, whereas patients in the outpatient environment sat in a treatment chair. There was higher microbial count during treatment (P < .001) with a higher microbial count associated with lower ultrasound amplitude (P = .028), lower saline flow rate (P = .010), no suction attachment (P = > .001), and a larger wound area (P = .002). All were independently associated with greater microorganism aerosolization. There was no correlation between the type of handpiece selected, the presence of wound infection, and the treatment time or treatment environment. This research has assisted in developing guidelines for cleaning of equipment and environments following treatment, as well as around the use of personal protective equipment required to protect the staff member and the patient during the use of LFUD. Additionally, recommendations have been made regarding the specific LFUD settings to reduce the risk of cross-infection to the clinic environment. These include selecting a higher ultrasound amplitude and saline flow rate as well as the use of suction where clinically possible. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Some physiological responses of wheat and bean to soil salinity at low matric suctions
NASA Astrophysics Data System (ADS)
Khatar, Mahnaz; Mohammadi, Mohammad Hossein; Shekari, Farid
2017-01-01
The effect of soil matric suction (2-33 kPa) and salinity (soil solution electrical conductivity 0.7-8 dS m-1 for bean and 2-20 dS m-1 for wheat) on some physiological characteristics of bean and wheat in a clay loam soil under greenhouse condition was investigated. The results showed that the leaf chlorophyll content index and potassium concentration decrease under salinity stress and increase with matric suction from 2 to 33 kPa suction for both plants. The wheat chlorophyll content index declines during the stress spell but bean chlorophyll content index remains nearly constant. The lowest values of the content of soluble sugars and the highest values of leaf proline content are observed at2 kPa matric suction (highest aeration stress) for bean and wheat. As matric suction increases from 2 to 6 kPa, the soluble sugars increases and proline content decreases significantly and then soluble sugars decreases and proline content increases until 10 kPa suction, and the soluble sugars remains nearly constant at the higher matric suctions for both plants. While the electrical conductivity effect on the soluble sugars is not significant, the values of proline content for both crop increase significantly with electrical conductivity. It was shown that the aeration stress can result in more considerable and rapid physiological responses, in comparison with salinity stress. There is a strong correlation between wheat and bean chlorophyll content index and potassium concentration under salinity and aeration stresses.
NASA Astrophysics Data System (ADS)
Rua, Yenny; Kharbouch, Karim; Sanford, Christopher; Reckinger, Shanon
2014-11-01
Suction feeding is the most common form of prey capture in aquatic vertebrates. During the early evolution of fishes there was a major change in shape of the mouth, from a wedge shaped mouth opening in more primitive fishes to a more circular and planar mouth. This change in shape resulted from increased mobility of a key upper jaw bone, the maxilla. It has been suggested that this change in shape dramatically increased suction feeding efficiency. This study examines the hydrodynamic effects of these two mouth shapes in the same animal, the bowfin fish (Amia calva). 2D Particle Image Velocimetry (PIV) is used to analyze suction feeding events. Post-processing algorithms have been developed to determine the flow rate of water into the mouth of the fish; the area of fluid, the velocity of fluid and the volume of fluid affected by the fish; the velocity of the fluid at the mouth, as well as the velocity of the fluid as a function of the distance from the mouth, finally the force exerted on the fluid by the fish is also determined. Lastly, a numerical model has been developed for comparison using a non-uniform mesh, which adapts dynamically in space and time to the fish feeding event. The realistic geometry of the fish's head is modeled in CAD.
Chung, Michael T.; Zimmermann, Andrew S.; Paik, Kevin J.; Morrison, Shane D.; Hyun, Jeong S.; Lo, David D.; McArdle, Adrian; Montoro, Daniel T.; Walmsley, Graham G.; Senarath-Yapa, Kshemendra; Sorkin, Michael; Rennert, Robert; Chen, Hsin-Han; Chung, Andrew S.; Vistnes, Dean; Gurtner, Geoffrey C.; Longaker, Michael T.
2013-01-01
Harvesting adipose-derived stromal cells (ASCs) for tissue engineering is frequently done through liposuction. However, several different techniques exist. Although third-generation ultrasound-assisted liposuction has been shown to not have a negative effect on ASCs, the impact of laser-assisted liposuction on the quality and differentiation potential of ASCs has not been studied. Therefore, ASCs were harvested from laser-assisted lipoaspirate and suction-assisted lipoaspirate. Next, in vitro parameters of cell yield, cell viability and proliferation, surface marker phenotype, osteogenic differentiation, and adipogenic differentiation were performed. Finally, in vivo bone formation was assessed using a critical-sized cranial defect in athymic nude mice. Although ASCs isolated from suction-assisted lipoaspirate and laser-assisted lipoaspirate both successfully underwent osteogenic and adipogenic differentiation, the cell yield, viability, proliferation, and frequency of ASCs (CD34+CD31−CD45−) in the stromal vascular fraction were all significantly less with laser-assisted liposuction in vitro (p < .05). In vivo, quantification of osseous healing by micro-computed tomography revealed significantly more healing with ASCs isolated from suction-assisted lipoaspirate relative to laser-assisted lipoaspirate at the 4-, 6-, and 8-week time points (p < .05). Therefore, as laser-assisted liposuction appears to negatively impact the biology of ASCs, cell harvest using suction-assisted liposuction is preferable for tissue-engineering purposes. PMID:24018794
Chung, Michael T; Zimmermann, Andrew S; Paik, Kevin J; Morrison, Shane D; Hyun, Jeong S; Lo, David D; McArdle, Adrian; Montoro, Daniel T; Walmsley, Graham G; Senarath-Yapa, Kshemendra; Sorkin, Michael; Rennert, Robert; Chen, Hsin-Han; Chung, Andrew S; Vistnes, Dean; Gurtner, Geoffrey C; Longaker, Michael T; Wan, Derrick C
2013-10-01
Harvesting adipose-derived stromal cells (ASCs) for tissue engineering is frequently done through liposuction. However, several different techniques exist. Although third-generation ultrasound-assisted liposuction has been shown to not have a negative effect on ASCs, the impact of laser-assisted liposuction on the quality and differentiation potential of ASCs has not been studied. Therefore, ASCs were harvested from laser-assisted lipoaspirate and suction-assisted lipoaspirate. Next, in vitro parameters of cell yield, cell viability and proliferation, surface marker phenotype, osteogenic differentiation, and adipogenic differentiation were performed. Finally, in vivo bone formation was assessed using a critical-sized cranial defect in athymic nude mice. Although ASCs isolated from suction-assisted lipoaspirate and laser-assisted lipoaspirate both successfully underwent osteogenic and adipogenic differentiation, the cell yield, viability, proliferation, and frequency of ASCs (CD34(+)CD31(-)CD45(-)) in the stromal vascular fraction were all significantly less with laser-assisted liposuction in vitro (p < .05). In vivo, quantification of osseous healing by micro-computed tomography revealed significantly more healing with ASCs isolated from suction-assisted lipoaspirate relative to laser-assisted lipoaspirate at the 4-, 6-, and 8-week time points (p < .05). Therefore, as laser-assisted liposuction appears to negatively impact the biology of ASCs, cell harvest using suction-assisted liposuction is preferable for tissue-engineering purposes.
Karsten, Jan; Meier, Torsten; Iblher, Peter; Schindler, Angela; Paarmann, Hauke; Heinze, Hermann
2014-02-01
Open endotracheal suctioning procedure (OSP) and recruitment manoeuvre (RM) are known to induce severe alterations of end-expiratory lung volume (EELV). We hypothesised that EIT lung volumes lack clinical validity. We studied the suitability of EIT to estimate EELV compared to oxygen wash-in/wash-out technique. Fifty-four postoperative cardiac surgery patients were enrolled and received standardized ventilation and OSP. Patients were randomized into two groups receiving either RM after suctioning (group RM) or no RM (group NRM). Measurements were conducted at the following time points: Baseline (T1), after suctioning (T2), after RM or NRM (T3), and 15 and 30 min after T3 (T4 and T5). We measured EELV using the oxygen wash-in/wash-out technique (EELVO2) and computed EELV from EIT (EELVEIT) by the following formula: EELVEITTx,y…=EELVO2+ΔEELI×VT/ΔZ. EELVEIT values were compared with EELVO2 using Bland-Altman analysis and Pearson correlation. Limits of agreement ranged from -0.83 to 1.31 l. Pearson correlation revealed significant results. There was no significant impact of RM or NRM on EELVO2-EELVEIT relationship (p=0.21; p=0.23). During typical routine respiratory manoeuvres like endotracheal suctioning or alveolar recruitment, EELV cannot be estimated by EIT with reasonable accuracy.
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....4680 Nonpowered, single patient, portable suction apparatus. (a) Identification. A nonpowered, single patient, portable suction apparatus is a device that consists of a manually operated plastic, disposable...
NASA Astrophysics Data System (ADS)
Birdsell, D.; Rajaram, H.; Dempsey, D.; Viswanathan, H.
2014-12-01
Understanding the transport of hydraulic fracturing (HF) fluid that is injected into the deep subsurface for shale gas extraction is important to ensure that shallow drinking water aquifers are not contaminated from an environmental and public health perspective and to understand formation damage from an oil and gas production perspective. Upward pressure gradients, permeable pathways such as faults or improperly abandoned wellbores, and the density contrast of the HF fluid to the surrounding brine encourages upward HF fluid migration. In contrast, the very low shale permeability and the imbibition of water into partially-saturated shale may sequester much of the HF fluid. Using the Finite Element Heat and Mass Transfer Code (FEHM), single-phase flow and transport simulations are performed to quantify how much HF fluid is removed via the wellbore as flowback and produced water and how much reaches overlying aquifers; imbibition is calculated with a semi-analytical one-dimensional solution and treated as a sink term. The travel time for HF fluid to reach the shallow aquifers is highly dependent on the amount of water imbibed and the suction applied to the well. If imbibition rates and suction are small, the pressure transient due to injection and the density contrast allows rapid upward plume migration at early times. The density contrast diminishes considerably within tens to hundreds of years as mixing occurs. We present estimates of HF fluid migration to shallow aquifers during the first 1,000 years after hydraulic fracturing begins for ranges of subsurface properties.
Simon, Scott Douglas; Grey, Casey Paul
2014-04-01
The Penumbra system uses a coaxial separator and continuous extracorporeal suction to remove a clot from a cerebral artery. Forced-suction thrombectomy (FST) involves aspirating clots through the same reperfusion catheter using only a syringe, decreasing the procedure time and supplies needed. To evaluate multiple combinations of catheters and syringes to determine the optimal pairing for use in FST. Tests were performed using both the Penumbra system and syringes to aspirate water through Penumbra 0.041 inch (041), 4Max, 0.054 inch (054) and 5Max reperfusion catheters and a shuttle sheath. Dynamic pressure and flow at the catheter tip were calculated from the fill times for each system. Static pressure and force for each aspiration source were determined with a vacuum gauge. All syringes provided significantly higher dynamic pressure at the catheter tip than the Penumbra system (p<0.001). Increasing syringe volume significantly increased static pressure (p<0.001). Both flow and aspiration force significantly increased with catheter size (p<0.001). Cases are presented to demonstrate the clinical value of the laboratory principles. Maximizing static and dynamic pressure when performing FST is achieved by aspirating with a syringe possessing both the largest volume and the largest inlet diameter available. Maximizing aspiration force and flow rate is achieved by using the largest catheter possible.
75 FR 43150 - Marine Mammals; File Nos. 10018, 13846, 14451, 14585, 14599, 14122, 14296, and 14353
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... of sloughed skin, photogrammetry, biopsy sampling, playback experiments, and/or suction- cup and... to individuals; (6) attachment of suction cup tags; (7) SCUBA observations; and (8) opportunistic.... Research will include vessel-based approaches: (1) to humpback whales for biological sampling, suction cup...
21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.
Code of Federal Regulations, 2014 CFR
2014-04-01
... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...
21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...
21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.
Code of Federal Regulations, 2011 CFR
2011-04-01
... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...
21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.
Code of Federal Regulations, 2012 CFR
2012-04-01
... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...
21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.
Code of Federal Regulations, 2013 CFR
2013-04-01
... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 874.5350 - Suction antichoke device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction antichoke device. 874.5350 Section 874.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Therapeutic Devices § 874.5350 Suction antichoke device. (a...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.5040 Suction lipoplasty system...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.5040 Suction lipoplasty system...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.5040 Suction lipoplasty system...
Experimental study of flow due to an isolated suction hole and a partially plugged suction slot
NASA Technical Reports Server (NTRS)
Goglia, G. L.; Wilkinson, S. P.
1980-01-01
Details for construction of a model of a partially plugged, laminar flow control, suction slot and an isolated hole are presented. The experimental wind tunnel facility and instrumentation is described. Preliminary boundary layer velocity profiles (without suction model) are presented and shown to be in good agreement with the Blasius laminar profile. Recommendations for the completion of the study are made. An experimental program for study of transition on a rotating disk is described along with preliminary disturbance amplification rate data.
Van Wassenbergh, Sam; Aerts, Peter; Herrel, Anthony
2006-01-01
The magnitude of sub-ambient pressure inside the bucco-pharyngeal cavity of aquatic animals is generally considered a valuable metric of suction feeding performance. However, these pressures do not provide a direct indication of the effect of the suction act on the movement of the prey item. Especially when comparing suction performance of animals with differences in the shape of the expanding bucco-pharyngeal cavity, the link between speed of expansion, water velocity, force exerted on the prey and intra-oral pressure remains obscure. By using mathematical models of the heads of catfishes, a morphologically diverse group of aquatic suction feeders, these relationships were tested. The kinematics of these models were fine-tuned to transport a given prey towards the mouth in the same way. Next, the calculated pressures inside these models were compared. The results show that no simple relationship exists between the amount of generated sub-ambient pressure and the force exerted on the prey during suction feeding, unless animals of the same species are compared. Therefore, for evaluating suction performance in aquatic animals in future studies, the focus should be on the flow velocities in front of the mouth, for which a direct relationship exists with the hydrodynamic force exerted on prey. PMID:16849247
Numerical Studies on a Rotor with Distributed Suction for Noise Reduction
NASA Astrophysics Data System (ADS)
Lutz, Thorsten; Arnold, Benjamin; Wolf, Alexander; Krämer, Ewald
2014-06-01
Minimizing the flow-induced noise is an important issue in the design of modern onshore wind turbines. There is a number of proven passive means to reduce the aeroacoustic noise, such as the implementation of serrations, porous trailing edges or the aeroacoustic airfoil design. The noise emission can be further reduced by active flow control techniques. In the present study the impact of distributed boundary layer suction on the noise emission of an airfoil and a complete rotor is investigated. Aerodynamic and aeroacoustic wind tunnel tests were performed for the NACA 64-418 airfoil and supplemented by numerical calculations. The aeroacoustic analyses have been conducted by means of the institute's Rnoise prediction scheme. The 2D studies have shown that noise reductions of 5 dB can be achieved by suction at moderate mass flow rates. To study the impact of three-dimensional effects numerical investigations have been conducted on the example of the generic NREL 5MW rotor with suction applied in the outer part of the blade. The predictions for the complete rotor provided smaller benefits compared to those for the isolated airfoil, mainly because the examined suction configurations were not optimized with respect to the extent of the suction patch and suction distribution.
Xu, Songao; Yu, Huijie; Sun, Hui; Zhu, Xiangyun; Xu, Xiaoqin; Xu, Jun; Cao, Weizhong
2017-01-01
To investigate the efficiency of closed tracheal suction system (CTSS) using novel splash-proof ventilator circuit component on ventilator-associated pneumonia (VAP) and the colonization of multiple-drug resistant bacteria (MDR) in patients undergoing mechanical ventilation (MV) prevention. A prospective single-blinded randomized parallel controlled intervention study was conducted. 330 severe patients admitted to the intensive care unit (ICU) of the First Hospital of Jiaxing from January 2014 to May 2016 were enrolled, and they were divided into open tracheal suction group, closed tracheal suction group, and splash-proof suction group on average by random number table. The patients in the three groups used conventional ventilator circuit component, conventional CTSS, and CTSS with a novel splash-proof ventilator circuit component for MV and sputum suction, respectively. The incidence of VAP, airway bacterial colonization rate, MDR and fungi colonization rate, duration of MV, length of ICU and hospitalization stay, and financial expenditure during hospitalization, as well as the in-hospital prognosis were recorded. After excluding patients who did not meet the inclusion criteria, incomplete data, backed out and so on, 318 patients were enrolled in the analysis finally. Compared with the open tracheal suction group, the total incidence of VAP was decreased in the closed tracheal suction group and splash-proof suction group [20.95% (22/105), 21.90% (23/105) vs. 29.63% (32/108)], but no statistical difference was found (both P > 0.05), and the incidence of VAP infections/1 000 MV days showed the same change tendency (cases: 14.56, 17.35 vs. 23.07). The rate of airway bacterial colonization and the rate of MDR colonization in the open tracheal suction group and splash-proof suction group were remarkably lower than those of closed tracheal suction group [32.41% (35/108), 28.57% (30/105) vs. 46.67% (49/105), 20.37% (22/108), 15.24% (16/105) vs. 39.05% (41/105)] with significantly statistical differences (all P < 0.05). Besides, no significantly statistical difference was found in the fungi colonization rate among open tracheal group, closed tracheal group, and splash-proof suction group (4.63%, 3.81% and 6.67%, respectively, P > 0.05). Compared with the closed tracheal suction group, the duration of MV, the length of ICU and hospitalization stay were shortened in the open tracheal suction group and splash-proof suction group [duration of MV (days): 8.00 (4.00, 13.75), 8.00 (5.00, 13.00) vs. 9.00 (5.00, 16.00); the length of ICU stay (days): 10.00 (6.00, 16.00), 11.00 (7.00, 19.00) vs. 13.00 (7.50, 22.00); the length of hospitalization stay (days): 16.50 (9.25, 32.00), 19.00 (10.50, 32.50) vs. 21.00 (10.00, 36.00)], and financial expenditure during hospitalization was lowered [10 thousand Yuan: 4.95 (3.13, 8.62), 5.47 (3.84, 9.41) vs. 6.52 (3.99, 11.02)] without significantly statistical differences (all P > 0.05). Moreover, no significantly statistical difference was found in the in-hospital prognosis among the three groups. CTSS performed using novel splash-proof ventilator circuit component shared similar advantages in preventing VAP with the conventional CTSS. Meanwhile, it is superior because it prevented the colonization of MDR and high price in the conventional CTSS.Clinical Trail Registration Chinese Clinical Trial Registry, ChiCTR-IOR-16009694.
2010-01-01
The time scale of the photoresponse in photoreceptor cells is set by the slowest of the steps that quench the light-induced activity of the phototransduction cascade. In vertebrate photoreceptor cells, this rate-limiting reaction is thought to be either shutoff of catalytic activity in the photopigment or shutoff of the pigment's effector, the transducin-GTP–phosphodiesterase complex. In suction pipette recordings from isolated salamander L-cones, we found that preventing changes in internal [Ca2+] delayed the recovery of the light response and prolonged the dominant time constant for recovery. Evidence that the Ca2+-sensitive step involved the pigment itself was provided by the observation that removal of Cl− from the pigment's anion-binding site accelerated the dominant time constant for response recovery. Collectively, these observations indicate that in L-cones, unlike amphibian rods where the dominant time constant is insensitive to [Ca2+], pigment quenching rate limits recovery and provides an additional mechanism for modulating the cone response during light adaptation. PMID:20231373
A numerical study of transition control by periodic suction-blowing
NASA Technical Reports Server (NTRS)
Biringen, Sedat
1987-01-01
The applicability of active control of transition by periodic suction-blowing is investigated via direct numerical simulations of the Navier-Stokes equations. The time-evolution of finite-amplitude disturbances in plane channel flow is compared in detail with and without control. The analysis indicates that, for relatively small three dimensional amplitudes, a two dimensional control effectively reduces disturbance growth rates even for linearly unstable Reynolds numbers. After the flow goes through secondary instability, three dimensional control seems necessary to stabilize the flow. An investigation of the temperature field suggests that passive temperature contamination is operative to reflect the flow dynamics during transition.
Pump tank divider plate for sump suction sodium pumps
George, John A.; Nixon, Donald R.
1977-01-01
A circular plate extends across the diameter of "sump suction" pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level.
Endotracheal Suctioning in Preterm Infants Using Four-Handed versus Routine Care
Cone, Sharon; Pickler, Rita H.; Grap, Mary Jo; McGrath, Jacqueline; Wiley, Paul M.
2013-01-01
Objective To evaluate the effect of four-handed care on preterm infants’ physiologic and behavioral responses to and recovery from endotracheal suctioning versus routine endotracheal (ETT) suctioning. Design Randomized crossover design with infants as their own controls. Setting Single-family-room newborn intensive care unit in an academic health center. Participants Ten intubated infants on conventional ventilation with inline suctioning who were fewer than 37 weeks gestation at birth, and less than one week of age. Methods Each infant was observed twice on a single day. One observation involved routine ETT suctioning and one involved four-handed care. Physiologic and behavioral response data were collected. Results No differences were noted when comparing baseline heart rate (HR) or oxygen saturation (SpO2) data to those obtained during and after suctioning while in the routine care condition. In the four-handed care condition, mean SpO2 increased from preobservation 95.49 to during observation saturation 97.75 (p = .001). Salivary cortisol levels did not differ between groups at baseline or postsuctioning. No significant difference in behavior state was observed between the two conditions. More stress and defense behaviors occurred postsuctioning when infants received routine care as opposed to four-handed care (p = .001) and more self-regulatory behaviors were exhibited by infants during (p = .019) and after suctioning (p = .016) when receiving four-handed care. No statistical difference was found in the number of monitor call-backs postsuctioning. Conclusions Four-handed care during suctioning was associated with a decrease in stress and defense behaviors and an increase in self-regulatory behaviors. PMID:23316894
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-17
...: Non-Powered Suction Apparatus Device Intended for Negative Pressure Wound Therapy; Availability AGENCY...-powered Suction Apparatus Device Intended for Negative Pressure Wound Therapy (NPWT).'' This guidance document describes a means by which non-powered suction apparatus devices intended for NPWT may comply with...
Liposuction: more curettage than aspiration.
Mottura, A A
1991-01-01
After infiltration with epinephrine solution in each adipose area, an 8- or 10-mm cannula, without the suction tube connected, was introduced. With a curettage maneuver and by directing the cannula upward, the fat began to come out spontaneously. After obtaining a considerable amount of fat, the suction tube was connected and the remaining fat tissue aspirated at low suction power (250 mm Hg). With this curettage maneuver adiposity of the abdomen, knees, and trochanteric areas can be reduced. However, in the back, buttocks, or thighs, where adiposity is more fibrous, aspiration is needed from the start in almost every case, but always at low-power suction. This procedure is indicated in particular for the face and neck and for secondary liposuction. The fact that fat comes out easily through the cannula (without suction) demonstrates that the curettage maneuver is more important than the aspiration. Only with curettage can a considerable amount of fat be removed. No fat is removed when aspiration of 1 atm without a curettage maneuver is used. Suction only helps to remove fat already mobilized and free in the cannula. Our experience includes 34 patients.
Morphology, Kinematics, and Dynamics: The Mechanics of Suction Feeding in Fishes.
Day, Steven W; Higham, Timothy E; Holzman, Roi; Van Wassenbergh, Sam
2015-07-01
Suction feeding is pervasive among aquatic vertebrates, and our understanding of the functional morphology and biomechanics of suction feeding has recently been advanced by combining experimental and modeling approaches. Key advances include the visualization of the patterns of flow in front of the mouth of a feeding fish, the measurement of pressure inside their mouth cavity, and the employment of analytical and computational models. Here, we review the key components of the morphology and kinematics of the suction-feeding system of anatomically generalized, adult ray-finned fishes, followed by an overview of the hydrodynamics involved. In the suction-feeding apparatus, a strong mechanistic link among morphology, kinematics, and the capture of prey is manifested through the hydrodynamic interactions between the suction flows and solid surfaces (the mouth cavity and the prey). It is therefore a powerful experimental system in which the ecology and evolution of the capture of prey can be studied based on first principals. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Dielectric elastomer actuators for octopus inspired suction cups.
Follador, M; Tramacere, F; Mazzolai, B
2014-09-25
Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.
Octopus-like suction cups: from natural to artificial solutions.
Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B
2015-05-13
Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.
Sawada, Shigeaki; Yamagishi, Fuminori; Suzuki, Syuuichiro; Matsuoha, Jiro; Arai, Hideki; Tsukada, Kazuhiro
2008-01-01
The management of pancreatic leakage is important after pancreatic resection because such leakagge can be associated with additional complications. In this paper, we present a new therapy "irrigation with suction" after pancreatic surgery. The addition of suction permits the start of irrigation early after surgery and prevents severe post-operative complications. Between January 1995 and June 2003, 29 consecutive patients underwent surgical treatment of the pancreas for a variety of indications. Among them, 18 patients were treated with continuous irrigation with suction prophylactically. In these 29 patients, we did not encounter any additional complications such as intraabdominal hemorrhage or abscess formation. A representative case report demonstrates the application of this treatment. The irrigation with suction therapy was started on the first post-operative day after the pylorus-preserving pancreatoduodenectomy with left lobectomy of the liver. CT with irrigation of contrast reagent showed that the reagent did not spread to the uninvolved abdominal area, and the patient did not develop hemorrhage or abscess. It seems that continuous irrigation with suction therapy was effective in preventing additional serious complications after pancreatic resection.
Zhang, Feng; Yang, Yahui; Bai, Ting; Sun, Lele; Sun, Mingzhu; Shi, Xueling; Zhu, Meng; Ge, Meijuan; Xia, Haiou
2018-01-01
Caesarean section is associated with weaker newborn suction pressure. This nonblinded, randomized trial explored the effect of suction pressures generating by a breast pump on mothers' onset of lactation and milk supply after caesarean section. A high pressure group (-150 mmHg), a low pressure group (-100 mmHg), and a control group (none) were generated under computer random assignment with concealed allocation in 2 tertiary hospitals. The breast pumping began within 2 hr after caesarean operation (6 times a day and 30 min per time) until onset of lactation. The primary outcomes were the timing of onset of lactation, milk supply, and mother's satisfaction in lactation, using both intention-to-treat and per-protocol analyses. The secondary endpoints were the pumping-related pain, nipple injury, and maternal fatigue. All 164 women randomized were included in analysis. The breast pumping at -150 mmHg optimally advanced the timing of the onset of lactation and increased daytime milk supply. The pumping also appeared to boost mothers' confidence in lactation. The results in the per-protocol population (n = 148) were consistent with those of intention-to-treat population (n = 164). However, the pumping aggravated maternal nipple pain and fatigue, though there was no statistical significance. The findings suggest that a higher pumping pressure within the range of normal vaginally born infant suction could promote onset of lactation and milk supply among mothers giving birth by caesarean section. The pumping could also enhance mothers' confidence in breastfeeding. © 2017 John Wiley & Sons Ltd.
5-year operation experience with the 1.8 K refrigeration units of the LHC cryogenic system
NASA Astrophysics Data System (ADS)
Ferlin, G.; Tavian, L.; Claudet, S.; Pezzetti, M.
2015-12-01
Since 2009, the Large Hadron Collider (LHC) is in operation at CERN. The LHC superconducting magnets distributed over eight sectors of 3.3-km long are cooled at 1.9 K in pressurized superfluid helium. The nominal operating temperature of 1.9 K is produced by eight 1.8-K refrigeration units based on centrifugal cold compressors (3 or 4 stages depending to the vendor) combined with warm volumetric screw compressors with sub-atmospheric suction. After about 5 years of continuous operation, we will present the results concerning the availability for the final user of these refrigeration units and the impact of the design choice on the recovery time after a system trip. We will also present the individual results for each rotating machinery in terms of failure origin and of Mean Time between Failure (MTBF), as well as the consolidations and upgrades applied to these refrigeration units.
Absence of Suction Feeding Ichthyosaurs and Its Implications for Triassic Mesopelagic Paleoecology
Motani, Ryosuke; Ji, Cheng; Tomita, Taketeru; Kelley, Neil; Maxwell, Erin; Jiang, Da-yong; Sander, Paul Martin
2013-01-01
Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were ‘ram-feeders’, without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the establishment of modern-style mesopelagic animal communities in the Triassic. This new interpretation matches the fossil record of coleoids, which indicates the absence of soft-bodied deepwater species in the Triassic. PMID:24348983
Early surgical suction and washout for treatment of cytotoxic drug extravasations.
Vandeweyer, E; Deraemaecker, R
2000-02-01
This case report is presented to assess safety and efficiency of early suction and saline washout of extravasated cytotoxic drugs. Through multiple small skin incisions, the area of extravasation is first suctioned and subsequently extensively washed out with saline. Incisions are left open and the arm is elevated for 24 hours. A complete healing was obtained in five days without any skin or soft tissue loss. No additional treatment was needed. Early referral and surgical treatment by suction and washout is a safe and reliable treatment protocol for major cytotoxic drug extravasation injuries.
Yanaki, Fumiko; Hirai, Yasuo; Hanada, Azusa; Ishitani, Ken; Matsui, Hideo
2017-01-01
We evaluated the clinical performance of liquid-based endometrial cytology (SurePath™) for detecting endometrial malignancies by comparison with the performance of suction endometrial tissue biopsy. From November 2011 to May 2013, we consecutively collected 1,118 liquid-based endometrial cytology specimens and 674 suction endometrial tissue biopsy specimens. The rate of nonpositive final histology in nonpositive liquid-based endometrial cytology (98.2%) was higher than the rate of nonpositive final histology in nonpositive suction endometrial tissue biopsy (97.0%). None of the clinical performance values of liquid-based endometrial cytology for detecting the endometrial malignancies were statistically inferior to those of the suction endometrial tissue biopsy. When the positivity threshold was more than "atypical endometrial cells of undetermined significance," the rate of positive liquid-based endometrial cytology from cases with a positive final histology (84.5%) was higher than the rate of positive suction endometrial tissue biopsy from cases with a positive final histology (69.8%). However, there were still no significant differences among all the performance values. Our liquid-based endometrial cytology would be more appropriate in various clinical situations as the initial detection tool for endometrial malignancies, rather than suction endometrial tissue biopsy. In addition, it could be used in screening for endometrial malignancies on a broader scale. © 2017 S. Karger AG, Basel.
Differing ERP patterns caused by suction and puff stimuli.
Choi, Mi-Hyun; Kim, Hyung-Sik; Baek, Ji-Hye; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Gim, Seon-Young; You, Ji Hye; Kim, Sung-Pil; Lim, Dae-Woon; Kim, Hyun-Jun; Chung, Soon-Cheol
2015-05-06
The present study compared event-related potential (ERP) patterns for two stimuli types, puff and suction, by applying these stimuli to the fingers; ERP patterns for the two stimuli were compared at C3, an area related to somatosensory perception, and at FC5, an area related to motor function. Participants were 12 healthy males in their 20s (mean age=23.1±2.0 years). One session consisted of a Control Phase (3s), a Stimulation Phase (3s), and a Rest Phase (9s). During the Stimulation Phase, a 4-psi suction or puff stimulus was applied to the first joint of the right index finger. After completion of the session, a subjective magnitude test was presented. In all phases, electroencephalography signals were recorded. We extracted maximum positive amplitude and minimum negative amplitude as well as relevant latency values for C3 and FC5 signals. Suction and puff stimuli had similar subjective magnitude scores. For both C3 and FC5, the maximum and minimum amplitude latency was reached earlier for the suction stimulus than for the puff stimulus. In conclusion, when suction and puff stimuli of the same intensity were applied to the fingers, the suction stimulus caused a more sensitive response in the somatosensory area (C3) and motor area (FC5) than did the puff stimulus. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Computer-assisted neurosurgical navigational system for transsphenoidal surgery--technical note.
Onizuka, M; Tokunaga, Y; Shibayama, A; Miyazaki, H
2001-11-01
Transsphenoidal surgery carries the risk of carotid artery injury even for very experienced neurosurgeons. The computer-assisted neurosurgical (CANS) navigational system was used to obtain more precise guidance, based on the axial and coronal images during the transsphenoidal approach for nine pituitary adenomas. The CANS navigator consists of a three-dimensional digitizer, a computer, and a graphic unit, which utilizes electromagnetic coupling technology to detect the spatial position of a suction tube attached to a magnetic sensor. Preoperatively, the magnetic resonance images are transferred and stored in the computer and the tip of the suction tube is shown on a real-time basis superimposed on the preoperative images. The CANS navigation system correctly displayed the surgical orientation and provided localization in all nine patients. No intraoperative complications were associated with the use of this system. However, outflow of cerebrospinal fluid during tumor removal may affect the accuracy, so the position of the probe when the tumor is removed must be accurately determined. The CANS navigator enables precise localization of the suction tube during the transsphenoidal approach and allows safer and less-invasive surgery.
Active chimney effect using heated porous layers: optimum heat transfer
NASA Astrophysics Data System (ADS)
Mehiris, Abdelhak; Ameziani, Djamel-Edine; Rahli, Omar; Bouhadef, Khadija; Bennacer, Rachid
2017-05-01
The purpose of the present work is to treat numerically the problem of the steady mixed convection that occurs in a vertical cylinder, opened at both ends and filled with a succession of three fluid saturated porous elements, namely a partially porous duct. The flow conditions fit with the classical Darcy-Brinkman model allowing analysing the flow structure on the overall domain. The induced heat transfer, in terms of local and average Nusselt numbers, is discussed for various controlling parameters as the porous medium permeability, Rayleigh and Reynolds numbers. The efficiency of the considered system is improved by the injection/suction on the porous matrices frontier. The undertaken numerical exploration particularly highlighted two possible types of flows, with and without fluid recirculation, which principally depend on the mixed convection regime. Thus, it is especially shown that recirculation zones appear in some domain areas under specific conditions, obvious by a negative central velocity and a prevalence of the natural convection effects, i.e., turnoff flow swirls. These latter are more accentuated in the areas close to the porous obstacles and for weak permeability. Furthermore, when fluid injection or suction is considered, the heat transfer increases under suction and reduces under injection. Contribution to the topical issue "Materials for Energy Harvesting, Conversion and Storage II (ICOME 2016)", edited by Jean-Michel Nunzi, Rachid Bennacer and Mohammed El Ganaoui
Lasocki, Sigismond; Lu, Qin; Sartorius, Alfonso; Fouillat, Dominique; Remerand, Francis; Rouby, Jean-Jacques
2006-01-01
Closed-circuit endotracheal suctioning (CES) is advocated for preventing hypoxemia caused by the loss of lung volume resulting from open endotracheal suctioning (OES). However, the efficiency of CES and OES on tracheal secretion removal has never been compared in patients with acute lung injury. The authors designed a two-part study aimed at comparing gas exchange and efficiency between OES and CES performed at two levels of negative pressure. Among 18 patients with acute lung injury, 9 underwent CES and OES at 3-h intervals in a random order using a negative pressure of -200 mmHg. Nine other patients underwent CES twice using two levels of negative pressure (-200 and -400 mmHg) applied in a random order. After each CES, a recruitment maneuver was performed using 20 consecutive hyperinflations. Tracheal aspirates were weighed after each suctioning procedure. Arterial blood gases were continuously recorded using an intravascular sensor. Open endotracheal suctioning induced a significant 18% decrease in arterial oxygen tension (Pa(O2)) (range, +13 to -71%) and an 8% increase in arterial carbon dioxide tension (Pa(CO2)) (range, -2 to +16%) that persisted 15 min after the end of the procedure. CES using -200 cm H2O did not change Pa(O2), but tracheal aspirate mass was lower compared with OES (0.6 +/- 1.0 vs. 3.2 +/- 5.1 g; P = 0.03). Increasing negative pressure to -400 cm H2O during CES did not change Pa(O2) but increased the tracheal aspirate mass (1.7 +/- 1.6 vs. 1.0 +/- 1.3 g; P = 0.02). Closed-circuit endotracheal suctioning followed by a recruitment maneuver prevents hypoxemia resulting from OES but decreases secretion removal. Increasing suctioning pressure enhances suctioning efficiency without impairing gas exchange.
Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M
2015-02-01
Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p < 0.001), and suction through a 12-Fr catheter resulted in an aspiration rate of 33 % (2/6 trials; p > 0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p < 0.001). Mean UES opening improved from 0.0 (±0.0) mm in the control condition to 8.6 (±0.2) mm with a hypopharyngeal catheter (16 Fr Foley catheter; p < 0.001). Negative pressure applied through retro-esophageal suction catheters (>12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.
J-2X Fuel Turbopump Point of Departure: The Performance of the J-2s Fuel Turbopump Inducer
NASA Technical Reports Server (NTRS)
Sargent, S. R.; Becht, D. G.; Mulder, A. D.
2008-01-01
To aid the J-2X program design effort with detailed performance and environment information, the J-2S fuel turbopump (FTP) inducer has undergone a thorough test series in both water and hydrogen. The test series utilizes both inducer only and a complete pump configuration to assess the inducer interaction to the overall turbopump system. The test goals include verification of suction performance against heritage J-2S data, head production, effects of thermodynamic suppression head (TSH), and evaluation of the inducer dynamic pressure caused by cavitation instabilities. Test facilities at both Pratt & Whitney Rocketdyne (PWR) and NASA s Stennis Space Center (SSC) are employed for the testing. The inducer only water test effort conducted at PWR established performance curves for suction performance, head production, and efficiency over a wide operating range. Because the heritage J-2S suction performance data set is in hydrogen, it is desired to obtain current suction performance data in hydrogen as well, thus avoiding the reliance on a theoretical TSH correlation for direct comparison. This data then provides an empirically based TSH correlation allowing for the comparison of water test suction data to system suction requirements. The FTP testing performed at SSC provides these suction performance relationships as well as inlet duct dynamic pressures during liquid hydrogen operation. The test effort successfully confirms the heritage J-2S suction performance and establishes the amount of TSH between water and hydrogen operation at the design flow coefficient. Correlating data is also obtained for cavitating instability frequency content, illustrating the validity of using the wide flow range water test data to predict hydrogen performance.
Prediction of the wetting-induced collapse behaviour using the soil-water characteristic curve
NASA Astrophysics Data System (ADS)
Xie, Wan-Li; Li, Ping; Vanapalli, Sai K.; Wang, Jia-Ding
2018-01-01
Collapsible soils go through three distinct phases in response to matric suction decrease during wetting: pre-collapse phase, collapse phase and post-collapse phase. It is reasonable and conservative to consider a strain path that includes a pre-collapse phase in which constant volume is maintained and a collapse phase that extends to the final matric suction to be experienced by collapsible soils during wetting. Upon this assumption, a method is proposed for predicting the collapse behaviour due to wetting. To use the proposed method, two parameters, critical suction and collapse rate, are required. The former is the suction value below which significant collapse deformations take place in response to matric suction decease, and the later is the rate at which void ratio reduces with matric suction in the collapse phase. The value of critical suction can be estimated from the water-entry value taking account of both the microstructure characteristics and collapse mechanism of fine-grained collapsible soils; the wetting soil-water characteristic curve thus can be used as a tool. Five sets of data of wetting tests on both compacted and natural collapsible soils reported in the literature were used to validate the proposed method. The critical suction values were estimated from the water-entry value with parameter a that is suggested to vary between 0.10 and 0.25 for compacted soils and to be lower for natural collapsible soils. The results of a field permeation test in collapsible loess soils were also used to validate the proposed method. The relatively good agreement between the measured and estimated collapse deformations suggests that the proposed method can provide reasonable prediction of the collapse behaviour due to wetting.
Integrated axial and tangential serpentine cooling circuit in a turbine airfoil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Ching-Pang; Jiang, Nan; Marra, John J
2015-05-05
A continuous serpentine cooling circuit forming a progression of radial passages (44, 45, 46, 47A, 48A) between pressure and suction side walls (52, 54) in a MID region of a turbine airfoil (24). The circuit progresses first axially, then tangentially, ending in a last radial passage (48A) adjacent to the suction side (54) and not adjacent to the pressure side (52). The passages of the axial progression (44, 45, 46) may be adjacent to both the pressure and suction side walls of the airfoil. The next to last radial passage (47A) may be adjacent to the pressure side wall andmore » not adjacent to the suction side wall. The last two radial passages (47A, 48A) may be longer along the pressure and suction side walls respectively than they are in a width direction, providing increased direct cooling surface area on the interiors of these hot walls.« less
Similarity transformation for equilibrium boundary layers, including effects of blowing and suction
NASA Astrophysics Data System (ADS)
Chen, Xi; Hussain, Fazle
2017-03-01
We present a similarity transformation for the mean velocity profiles in sink flow turbulent boundary layers, including effects of blowing and suction. It is based on symmetry analysis which transforms the governing partial differential equations (for mean mass and momentum) into an ordinary differential equation and yields a new result including an exact, linear relation between the mean normal (V ) and streamwise (U ) velocities. A characteristic length function is further introduced which, under a first order expansion (whose coefficient is η ) in wall blowing and suction velocity, leads to the similarity transformation for U with the value of η ≈-1 /9 . This transformation is shown to be a group invariant and maps different U profiles under different blowing and suction conditions into a (universal) profile for no blowing or suction. Its inverse transformation enables predictions of all mean quantities in the mean mass and momentum equations, in good agreement with DNS data.
NASA Astrophysics Data System (ADS)
Kumar, L. Madan Ananda; Sivaramakrishnan, V.; Premalatha, M.; Vivekanandan, M.
2017-07-01
The zero energy building considered is a single storey building in Tiruchirappalli city retrofitted with various green features. This study investigated the effect of a suction opening orientation on a vertical solar chimney (VSC), integrated into a one-storey building. It was designed, manufactured and tested through selection of different suction openings for the entry of air, including right, left, front, back, both right and left and both front and back sides. Genetic algorithm (GA) calculates maximum air flow rate for a building with VSC for better suction opening, in Tiruchirappalli's dry, environmental conditions. GA is a useful technique for finding an improved suction opening specifically in the presence of a host of independent parameters which are large. The obtained results are related to fluid flow temperature distribution along the chimney, mass flow rate and air change per hour. The findings between the GA and the experimental results show sound agreement.
NASA Astrophysics Data System (ADS)
Flaszynski, Pawel; Doerffer, Piotr; Szwaba, Ryszard; Kaczynski, Piotr; Piotrowicz, Michal
2015-11-01
The shock wave boundary layer interaction on the suction side of transonic compressor blade is one of the main objectives of TFAST project (Transition Location Effect on Shock Wave Boundary Layer Interaction). In order to investigate the flow structure on the suction side of a profile, a design of a generic test section in linear transonic wind tunnel was proposed. The experimental and numerical results for the flow structure investigations are shown for the flow conditions as the existing ones on the suction side of the compressor profile. Near the sidewalls the suction slots are applied for the corner flow structure control. It allows to control the Axial Velocity Density Ratio (AVDR), important parameter for compressor cascade investigations. Numerical results for Explicit Algebraic Reynolds Stress Model with transition modeling are compared with oil flow visualization, schlieren and Pressure Sensitive Paint. Boundary layer transition location is detected by Temperature Sensitive Paint.
Turbine blade with contoured chamfered squealer tip
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Ching-Pang
2014-12-30
A squealer tip formed from a pressure side tip wall and a suction side tip wall extending radially outward from a tip of the turbine blade is disclosed. The pressure and suction side tip walls may be positioned along the pressure sidewall and the suction sidewall of the turbine blade, respectively. The pressure side tip wall may include a chamfered leading edge with film cooling holes having exhaust outlets positioned therein. An axially extending tip wall may be formed from at least two outer linear surfaces joined together at an intersection forming a concave axially extending tip wall. The axiallymore » extending tip wall may include a convex inner surface forming a radially outer end to an inner cavity forming a cooling system. The cooling system may include one or more film cooling holes in the axially extending tip wall proximate to the suction sidewall, which promotes increased cooling at the pressure and suction sidewalls.« less
Determination of minimum suction level necessary for field dental units.
Charlton, David G
2010-04-01
A significant problem with most field dental units is that their suction is too weak to effectively remove debris from the mouth. The purpose of this study was to determine the minimum clinically acceptable suction level for routine dentistry. A vacuum pump was connected to a high-volume dental evacuation line in a simulated clinical setting and different suction airflow rates were evaluated by nine evaluator dentists for their capability to effectively remove amalgam debris and water. Airflow levels were rated as "clinically acceptable" or "clinically unacceptable" by each evaluator. Data were analyzed using a chi2 test for trend. Analysis indicated a significant linear trend between airflow and ratings (p < 0.0001). The first airflow level considered by all evaluators as producing clinically acceptable suction was 4.5 standard cubic feet per minute (0.127 standard cubic meters per minute). This value should be the minimum level required for all military field dental units.
Holzman, Roi; China, Victor; Yaniv, Sarit; Zilka, Miri
2015-07-01
Larval fishes suffer prodigious mortality rates, eliminating 99% of the cohort within a few days after their first feeding. Hjort (1914) famously attributed this "critical period" of low survival to larval inability to obtain sufficient food. We discuss recent experimental and modeling work, suggesting that the viscous hydrodynamic regime have marked effects on the mechanism of suction feeding in larval fish. As larvae grow, the size of the gape and associated volume of the mouth increase. At the same time, larvae swim faster and can generate faster suction flows, thus transiting to a hydrodynamic regime of higher Reynolds numbers. This hydrodynamic regime further leads to changes in the spatio-temporal patterns of flow in front of the mouth, and an increasing ability in larger larvae to exert suction forces on the prey. Simultaneously, the increase in swimming speed and the distance from which the prey is attacked result in higher rates of encountering prey by larger (older) larvae. In contrast, during the first few days after feeding commence the lower rates of encounter and success in feeding translate to low feeding rates. We conclude that young larvae experience "hydrodynamic starvation," in which low Reynolds numbers mechanically limit their feeding performance even under high densities of prey. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Water vacuum suction curettage (WVSC): one year's experience.
Woods, J R; Herrick, C N; White, R M
1973-05-01
At Tripler Army Medical Center in Honolulu abortion patients underwent suction curettage using either an electric pump unit (21, group A) or a simple water vacuum pump (WVSC) (28, group B). In both groups the use of the flexible 6 mm uterine curette and method of curettage were the same. For groups A and B the average blood losses were 40 ml and 39 ml. Average tissue volumes removed were 26 ml and 39 ml (greater yield reflects more patients at gestation of 9-10 weeks). From September 1971 to August 1972 400 patients of gestation of 10 weeks or less were curettaged using WVSC. Most of the operations were performed by first-year residents. Complications requiring readmission were not skewed towards largest gestations but distributed throughout the groups suggesting importance of individual technique in equipment use. The complications included retained products of conception (6), endometritis (2), endometritis with retained products of conception (3), and hermorrhage (1). Advantages of the WVSC unit are 1) quiet sound of running water rather than harsh sound of electric pump, 2) requirement of only a standard waterhead making method available to impoverished areas where electricity may be precious, 3) failsafe, unidirectional suction, 4) easy storage, transport, and assemblage, and 5) lack of need for safety pop-off valve because of intrinsic lag time from close of system to development of maximum suction. With its simplicity, safety, and flexibility WVSC is best suited for outpatients.
Dean vortices with wall flux in a curved channel membrane system. 2: The velocity field
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, K.Y.; Brewster, M.E.; Belfort, G.
1996-02-01
The velocity and pressure fields and the effect of wall flux on these fields in a spiral channel are presented. As fluid flows inward through a spiral channel with constant gap and permeable walls, the streamwise flux decreases while the curvature increases. Thus, by balancing the stabilizing effect of wall suction with the destabilizing effect of increasing curvature, established vortices can be maintained along the spiral channel. This approach is used to prescribe spiral geometries with different wall fluxes. Using a weakly nonlinear stability analysis, the influence of wall flux on the characteristics of Dean vortices is obtained. The criticalmore » Dean number is reduced when suction is through the inner wall only, is slightly reduced when suction is equal through both walls, and is increased when suction is through the outer wall only. The magnitude of change is proportional to a ratio of small numbers that measures the importance of the effect of curvature. In membrane filtration applications the wall flux is typically 2 to 5 orders of magnitude less than the streamwise flow. If the radius of curvature of the channel is of the order of 100 times the channel gap, the effect on the critical Dean number is within 2% of the no-wall flux case. If the radius of curvature is sufficiently large, however, it is possible to observe effects on the critical Dean number that approach O(1) in magnitude for certain parameter ranges.« less
75 FR 53271 - Marine Mammals; File No. 15271
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-31
... suction-cup tagged, 10 would be dart-tagged, and 10 would be tagged with small implantable tags; 30 fin whales would be approached for photo-ID and biopsy, of which 10 would be suction-cup tagged, 5 would be... approached for photo-ID and biopsy, of which 30 would be suction-cup tagged, 10 would be dart-tagged, and 10...
NASA Astrophysics Data System (ADS)
Lischeid, G.; Kolb, A.; Alewell, C.; Paul, S.
2007-01-01
Biologically mediated redox processes in the riparian zone, like denitrification, can have substantially beneficial impacts on stream water quality. The extent of these effects, however, depends greatly on the hydrological boundary conditions. The impact of hydrological processes on a wetland's nitrogen sink capacity was investigated in a forested riparian fen which is drained by a first-order perennial stream. Here, we analysed the frequency distributions and time-series of pH and nitrogen, silica, organic carbon and oxygen concentrations in throughfall, soil solution, groundwater and stream water, and the groundwater levels and stream discharges from a 3-year period. During baseflow conditions, the stream was fed by discharging shallow, anoxic groundwater and by deep, oxic groundwater. Whereas the latter delivered considerable amounts of nitrogen (0.37 mg l-1) to the stream, the former was almost entirely depleted of nitrogen. During stormflow, near-surface runoff in the upper 30 cm soil layer bypassed the denitrifying zone and added significant amounts to the nitrogen load of the stream. Nitrate-nitrogen was close to 100% of deep groundwater and stream-water nitrogen concentration. Stream-water baseflow concentrations of nitrate, dissolved carbon and silica were about 1.6 mg l-1, 4 mg l-1 and 7.5 mg l-1 respectively, and >3 mg l-1, >10 mg l-1 and <4 mg l-1 respectively during discharge peaks. In addition to that macroscale bypassing effect, there was evidence for a corresponding microscale effect: Shallow groundwater sampled by soil suction cups indicated complete denitrification and lacked any seasonal signal of solute concentration, which was in contrast to piezometer samples from the same depth. Moreover, mean solute concentration in the piezometer samples resembled more that of suction-cup samples from shallower depth than that of the same depth. We conclude that the soil solution cups sampled to a large extent the immobile soil-water fraction. In contrast, the mobile fraction that was sampled by the piezometers exhibited substantially shorter residence time, thus being less exposed to denitrification, but predominating discharge of that layer to the stream. Consequently, assessing the nitrogen budget based on suction-cup data tended to overestimate the nitrogen consumption in the riparian wetland. These effects are likely to become more important with the increased frequency and intensity of rainstorms that are expected due to climate change. Copyright
NASA Technical Reports Server (NTRS)
Weinstein, Leonard M.
2003-01-01
An apparatus to catch paint overspray has been proposed. Overspray is an unavoidable parasitic component of spray that occurs because the flow of air or other gas in the spray must turn at the sprayed surface. Very small droplets are carried away in this turning flow, and some land on adjacent surfaces not meant to be painted. The basic principle of the paint-spray catcher is to divert the overspray into a suction system at the boundary of the area to be painted. The paint-spray catcher (see figure) would include a toroidal plenum connected through narrow throat to a nozzle that would face toward the center of the torus, which would be positioned over the center of the area to be spray-painted. The plenum would be supported by four tubes that would also serve as suction exhaust ducts. The downstream ends of the tubes (not shown in the figure) would be connected to a filter on a suction pump. The pump would be rated to provide a suction mass flow somewhat greater than that of the directed spray gas stream, so that the nozzle would take in a small excess of surrounding gas and catch nearly all of the overspray. A small raised lip at the bottom edge of the nozzle would catch paint that landed inside the nozzle. Even if the paint is directly piston pumped, the droplets entrain an air flow by time they approach the wall, so there is always a gas stream to carry the excess droplets to the side. For long-duration spraying operations, it could be desirable to include a suction-drain apparatus to prevent overflowing and dripping of paint from inside the lip. A version without an external contraction and with the throat angled downward would be a more compact version of catcher, although it might be slightly less efficient.
Li Bassi, Gianluigi; Curto, Francesco; Zanella, Alberto; Stylianou, Mario; Kolobow, Theodor
2007-03-01
In patients intubated with endotracheal tubes (ETTs), suctioning is routinely performed to remove mucus from within the ETT and trachea. The Mucus Slurper is a novel ETT with built-in suction ports arranged radially at its tip. We evaluated the safety and efficacy of the Mucus Slurper, compared with conventional tracheal suction, to prevent airway obstruction in sheep with the ETT and trachea oriented below horizontal. Prospective randomized animal study. Animal research facility at the National Institutes of Health. Twelve healthy sheep. Sheep were randomized to be intubated with either the Mucus Slurper (study group) or a Hi-Lo Tracheal Tube (Mallinckrodt, St. Louis, MO) (control group) and mechanically ventilated for 72 hrs. In the study group, automatic, timed tracheal aspiration lasted 0.3 secs, was repeated every 2 mins, and was synchronized with the early expiratory phase. In the control group, tracheal suction was performed every 6 hrs or as required. In the control group, tracheal secretions accumulated progressively within the ETT and the trachea. In the study group, all mucus that reached the tip of the Mucus Slurper was aspirated, keeping the lumen of the ETT, and proximal trachea, free from secretions. In the study group, expiratory water trap protein concentration, a crude index to measure mucus drainage through the ETT, was consistently less than the control group (p < .001). At autopsy, no macroscopic injury to the tracheal mucosa was found in either group. In the study group, the respiratory circuit was less colonized than in the control group. There were no statistically significant differences between the two groups in bacterial colonization of the lungs/bronchi. The Mucus Slurper, combined with orientation of the trachea below horizontal, prevents accumulation of secretions within the lumen of the ETT and trachea, without need for conventional tracheal suctioning.
RATE-DEPENDENT PULL-OUT BEARING CAPACITY OF PILES BY SIMILITUDE MODEL TESTS USING SEEPAGE FORCE
NASA Astrophysics Data System (ADS)
Kato, Tatsuya; Kokusho, Takaji
Pull-out test of model piles was conducted by varying the pull-out velocity and skin friction of piles using a seepage force similitude model test apparatus. Due to the seepage consolidation under the pressure of 150kPa, the effective stress distribution in a prototype saturated soil of 17m could be successfully reproduced in the model ground of 28cm thick, in which the pull-out tests were carried out. The pull-out load rose to a peak value at small displacement, and then decreased to a residual value. At the same time, pore pressure in the vicinity of the pile decreased due to suction near the tip and the positive dilatancy near the pile skin. The maximum pull-out load, pile axial load, side friction and the corresponding displacement increased dramatically with increasing pull-out velocity. It was found that these rate-dependent trends become more prominent with increasing skin friction.
NASA Astrophysics Data System (ADS)
Marsan, A.; Trébinjac, I.; Coste, S.; Leroy, G.
2013-12-01
The temporal behaviour of a flow separation in the hub-suction side corner of a transonic diffuser is studied thanks to unsteady numerical simulations based on the phase-lagged approach. The validity of the numerical results is confirmed by comparison with experimental unsteady pressure measurements. An analysis of the instantaneous skin-friction pattern and particles trajectories is presented. It highlights the topology of the separation and its temporal behaviour. The major result is that, despite of a highly time-dependent core flow, the separation is found to be a "fixed unsteady separation" characterized by a fixed location of the main saddle of the separation but an extent of the stall region modulated by the pressure waves induced by the impeller-diffuser interaction.
Secondary subharmonic instability of boundary layers with pressure gradient and suction
NASA Technical Reports Server (NTRS)
El-Hady, Nabil M.
1988-01-01
Three-dimensional linear secondary instability is investigated for boundary layers with pressure gradient and suction in the presence of a finite amplitude TS wave. The focus is on principal parametric resonance responsible for a strong growth of subharmonics in a low disturbance environment. Calculations are presented for the effect of pressure gradients and suction on controlling the onset and amplification of the secondary instability.
NASA Technical Reports Server (NTRS)
Sawada, H.; Sakakibara, S.; Sato, M.; Kanda, H.; Karasawa, T.
1984-01-01
A quantitative evaluation method of the suction effect from a suction plate on side walls is explained. It is found from wind tunnel tests that the wall interference is basically described by the summation form of wall interferences in the case of two dimensional flow and the interference of side walls.
108. DETAIL OF DENVER DISC FILTER IN CO91107, SUCTION END. ...
108. DETAIL OF DENVER DISC FILTER IN CO-91-107, SUCTION END. NOTE BEARING HOUSING WITH CAST LOGO, SUCTION PIPE GOING OFF TO THE RIGHT, AND FILTER DISC IN BACKGROUND. VACUUM INSIDE DISCS FURTHER DEWATERED CONCENTRATE. AS DISC SLOWLY ROTATED A BAR SCRAPED DRIED CONCENTRATE FROM OUTSIDE OF FILTER CLOTH. - Shenandoah-Dives Mill, 135 County Road 2, Silverton, San Juan County, CO
Effects of suction dredging on streams: a review and an evaluation strategy
Bret C. Harvey; Thomas E. Lisle
1998-01-01
Abstract - Suction dredging for gold in river channels is a small-scale mining practice whereby streambed material is sucked up a pipe, passed over a sluice box to sort out the gold, and discarded as tailings over another area of bed. Natural resource managers should be concerned about suction dredging because it is common in streams in western North America that...
NASA Technical Reports Server (NTRS)
Srokowski, A. J.
1978-01-01
The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.
Code of Federal Regulations, 2011 CFR
2011-10-01
... having jurisdiction over the lands. (b) Suction dredges. (1) If your operations involve the use of a suction dredge, the State requires an authorization for its use, and BLM and the State have an agreement... suction dredge not covered by paragraph (b)(1) of this section, you must contact BLM before beginning such...
[Metabolic and cardiovascular consequences of suction-assisted lipectomy: Systematic review].
Crahay, F-X; Nizet, J L
2016-08-01
Suction-assisted lipectomy is one of the most frequent procedures in plastic surgery. The aim of this study was to investigate whether suction-assisted lipectomy causes changes in the carbohydrates and lipid metabolism and the potential effects on cardiovascular risk factors. We interrogated five databases: Medline, American College of Physicians Journal Club Database, Cochrane central register of controlled trials, Cochrane database of systematic reviews, Database of abstracts of reviews of effects. A systematic review of the literature was performed in order to compare results of randomized controlled trials and observational studies concerning changes in weight, metabolism, endocrinology, inflammatory markers and cardiovascular risk factors after suction-assisted lipectomy. All articles were assessed by criteria from Oxford Center For Evidence Based Medicine (OCEBM). The search resulted in 40 articles: 12 experimental animal studies and 28 human studies. Different metabolic parameters are affected by suction-assited lipectomy. First, all articles point out a decrease of body weight after suction-assisted lipectomy. Weight lost only affects fat mass without any change of lean mass. The potential compensatory growth of visceral fat seems to be counteracted by physical activity. Then, resting energy expenditure seems to be stable or decrease after the surgery. This reduction is significantly related to the decrease of leptin levels and also seems to be counteracted by physical activity. About adipocytokines, leptin level decreases after suction-assisted lipectomy while results are contradictory about adiponectin and resistin levels. However adiponectin seems to tend to increase after surgery. Inflammatory markers seem to increase within first hours after surgery. Then they seem to decrease or remain at the preoperative levels. Fasting insulin level decreases and is linked to the aspirated volume. So insulin sensitivity seems to be improved. Concerning lipid profil, it tends to remain the same or to be improved by suction-assisted lipectomy. In conclusion, regarding all the literature, there is still debate about metabolic effect of suction-assisted lipectomy. Prospective clinical studies are needed to confirm or invalidate some hypotheses. These studies must consider some potential biases as physical activity, diet and medical treatment modifications (statins). Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Forbes, Thomas P.; Staymates, Matthew
2017-01-01
Venturi-assisted ENTrainment and Ionization (VENTI) was developed, demonstrating efficient entrainment, collection, and transport of remotely sampled vapors, aerosols, and dust particulate for real-time mass spectrometry (MS) detection. Integrating the Venturi and Coandă effects at multiple locations generated flow and analyte transport from non-proximate locations and more importantly enhanced the aerodynamic reach at the point of collection. Transport through remote sampling probes up to 2.5 m in length was achieved with residence times on the order of 10-2 s to 10-1 s and Reynolds numbers on the order of 103 to 104. The Venturi-assisted entrainment successfully enhanced vapor collection and detection by greater than an order of magnitude at 20 cm stand-off (limit of simple suction). This enhancement is imperative, as simple suction restricts sampling to the immediate vicinity, requiring close proximity to the vapor source. In addition, the overall aerodynamic reach distance was increased by approximately 3-fold over simple suction under the investigated conditions. Enhanced aerodynamic reach was corroborated and observed with laser-light sheet flow visualization and schlieren imaging. Coupled with atmospheric pressure chemical ionization (APCI), the detection of a range of volatile chemical vapors; explosive vapors; explosive, narcotic, and mustard gas surrogate (methyl salicylate) aerosols; and explosive dust particulate was demonstrated. Continuous real-time Venturi-assisted monitoring of a large room (approximately 90 m2 area, 570 m3 volume) was demonstrated for a 60-minute period without the remote sampling probe, exhibiting detection of chemical vapors and methyl salicylate at approximately 3 m stand-off distances within 2 minutes of exposure. PMID:28107830
Forbes, Thomas P; Staymates, Matthew
2017-03-08
Venturi-assisted ENTrainment and Ionization (VENTI) was developed, demonstrating efficient entrainment, collection, and transport of remotely sampled vapors, aerosols, and dust particulate for real-time mass spectrometry (MS) detection. Integrating the Venturi and Coandă effects at multiple locations generated flow and analyte transport from non-proximate locations and more importantly enhanced the aerodynamic reach at the point of collection. Transport through remote sampling probes up to 2.5 m in length was achieved with residence times on the order of 10 -2 s to 10 -1 s and Reynolds numbers on the order of 10 3 to 10 4 . The Venturi-assisted entrainment successfully enhanced vapor collection and detection by greater than an order of magnitude at 20 cm stand-off (limit of simple suction). This enhancement is imperative, as simple suction restricts sampling to the immediate vicinity, requiring close proximity to the vapor source. In addition, the overall aerodynamic reach distance was increased by approximately 3-fold over simple suction under the investigated conditions. Enhanced aerodynamic reach was corroborated and observed with laser-light sheet flow visualization and schlieren imaging. Coupled with atmospheric pressure chemical ionization (APCI), the detection of a range of volatile chemical vapors; explosive vapors; explosive, narcotic, and mustard gas surrogate (methyl salicylate) aerosols; and explosive dust particulate was demonstrated. Continuous real-time Venturi-assisted monitoring of a large room (approximately 90 m 2 area, 570 m 3 volume) was demonstrated for a 60-min period without the remote sampling probe, exhibiting detection of chemical vapors and methyl salicylate at approximately 3 m stand-off distances within 2 min of exposure. Published by Elsevier B.V.
Factors involved in dental surgery fires: a review of the literature.
VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Walker, LaQuia A
2014-01-01
Surgical fires are well-characterized, readily preventable, potentially devastating operating room catastrophes that continue to occur from 20 to 100 times per year or, by one estimate, up to 600 times per year in US operating rooms, sometimes with fatal results. The most significant risk factors for surgical fires involve (a) the use of an ignition source, such as laser or electrocautery equipment, in or around an oxygen-enriched environment in the head, neck, and upper torso area and (b) the concurrent delivery of supplemental oxygen, especially via nasal cannula. Nonetheless, while these 2 conditions occur very commonly in dental surgery, especially in pediatric dental surgery where sedation and anesthesia are regularly indicated, there is a general absence of documented dental surgical fires in the literature. Barring the possibility of underreporting for fear of litigation, this may suggest that there is another mechanism or mechanisms present in dental or pediatric dental surgery that mitigates this worst-case risk of surgical fires. Some possible explanations for this include: greater fire safety awareness by dental practitioners, incidental ventilation of oxygen-enriched environments in patient oral cavities due to breathing, or suction used by dental practitioners during procedures. This review of the literature provides a background to suggest that the practice of using intraoral suction in conjunction with the use of supplemental oxygen during dental procedures may alter the conditions needed for the initiation of intraoral fires. To date, there appear to be no published studies describing the ability of intraoral suctioning devices to alter the ambient oxygen concentration in an intraoral environment. In vivo models that would allow examination of intraoral suction on the ambient oxygen concentration in a simulated intraoral environment may then provide a valuable foundation for evaluating the safety of current clinical dental surgical practices, particularly in regard to the treatment of children.
NASA Technical Reports Server (NTRS)
Thiede, P.
1978-01-01
The transition of the laminar boundary layer into the turbulent state, which results in an increased drag, can be avoided by sucking of the boundary layer particles near the wall. The technically-interesting case of sucking the particles using individual slits is investigated for bodies of revolution in incompressible flow. The results of the variational calculations show that there is an optimum suction height, where the slot separations are maximum. Combined with favorable shaping of the body, it is possible to keep the boundary layer over bodies of revolution laminar at high Reynolds numbers using relatively few suction slits and small amounts of suction flow.
NASA Astrophysics Data System (ADS)
Sivaiah, R.; Hemadri Reddy, R.
2017-11-01
In this paper, we investigate the peristaltic transport of a conducting Newtonian fluid bounded by permeable walls with suction and injection moving with constant velocity of the wave in the wave frame of reference under the consideration of long wavelength and low Reynolds number. The analytical solution for the velocity field, pressure gradient and the frictional force are obtained. The effect of suction/injection parameter, amplitude ratio and the permeability parameter including slip on the flow quantities are discussed graphically. It is found that the greater the suction/injection parameter, the smaller the pressure rise against the pump works. Further, the pressure rise increases with increasing Magnetic parameter.
A law of the wall for turbulent boundary layers with suction: Stevenson's formula revisited
NASA Astrophysics Data System (ADS)
Vigdorovich, Igor
2016-08-01
The turbulent velocity field in the viscous sublayer of the boundary layer with suction to a first approximation is homogeneous in any direction parallel to the wall and is determined by only three constant quantities — the wall shear stress, the suction velocity, and the fluid viscosity. This means that there exists a finite algebraic relation between the turbulent shear stress and the longitudinal mean-velocity gradient, using which as a closure condition for the equations of motion, we establish an exact asymptotic behavior of the velocity profile at the outer edge of the viscous sublayer. The obtained relationship provides a generalization of the logarithmic law to the case of wall suction.
Development of high temperature transport technology for LiCl-KCl eutectic salt in pyroprocessing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sung Ho; Lee, Hansoo; Kim, In Tae
The development of high-temperature transport technologies for molten salt is a prerequisite and a key issue in the industrialization of pyro-reprocessing for advanced fuel cycle scenarios. The solution of a molten salt centrifugal pump was discarded because of the high corrosion power of a high temperature molten salt, so the suction pump solution was selected. An apparatus for salt transport experiments by suction was designed and tested using LiC-KCl eutectic salt. The experimental results of lab-scale molten salt transport by suction showed a 99.5% transport rate (ratio of transported salt to total salt) under a vacuum range of 100 mtorrmore » - 10 torr at 500 Celsius degrees. The suction system has been integrated to the PRIDE (pyroprocessing integrated inactive demonstration) facility that is a demonstrator using non-irradiated materials (natural uranium and surrogate materials). The performance of the suction pump for the transport of molten salts has been confirmed.« less
NASA Technical Reports Server (NTRS)
Saric, William S.
1988-01-01
The effects of normal mass injection and suction on boundary-layer stability and transition are studied on a flat plate. Titanium panels, in which 0.063 mm diameter holes were drilled on 0.635 mm centers, are inserted in the plate. Suction level and distribution are variable. Disturbances are introduced by means of a vibrating ribbon and measurements of both mean- and disturbance-flow velocities are made with a hot wire. Disturbance amplitudes are measured as a function of Reynolds number, frequency, and suction characteristics, and are compared with the previous results obtained over a Dynapore surface. Transition measurements under natural and forced conditions are also made. The stabilizing effects of suction are documented. It is also shown that very high local flow rates through the suction holes (which approach a hole Reynolds number of 300) do not destabilize the flow. On the other hand, weak blowing lowers the transition Reynolds number, but is found not to cause serious problems.
The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.
Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce
2013-01-01
Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.
On the Active and Passive Flow Separation Control Techniques over Airfoils
NASA Astrophysics Data System (ADS)
Moghaddam, Tohid; Banazadeh Neishabouri, Nafiseh
2017-10-01
In the present work, recent advances in the field of the active and passive flow separation control, particularly blowing and suction flow control techniques, applied on the common airfoils are briefly reviewed. This broad research area has remained the point of interest for many years as it is applicable to various applications. The suction and blowing flow control methods, among other methods, are more technically feasible and market ready techniques. It is well established that the uniform and/or oscillatory blowing and suction flow control mechanisms significantly improve the lift-to-drag ratio, and further, postpone the boundary layer separation as well as the stall. The oscillatory blowing and suction flow control, however, is more efficient compared to the uniform one. A wide range of parameters is involved in controlling the behavior of a blowing and/or suction flow control, including the location, length, and angle of the jet slots. The oscillation range of the jet slot is another substantial parameter.
El Sayed, Salah Mohamed; Baghdadi, Hussam; Abou-Taleb, Ashraf; Mahmoud, Hany Salah; Maria, Reham A; Ahmed, Nagwa S; Helmy Nabo, Manal Mohamed
2014-01-01
Iron overload causes iron deposition and accumulation in the liver, heart, skin, and other tissues resulting in serious tissue damages. Significant blood clearance from iron and ferritin using wet cupping therapy (WCT) has been reported. WCT is an excretory form of treatment that needs more research efforts. WCT is an available, safe, simple, economic, and time-saving outpatient modality of treatment that has no serious side effects. There are no serious limitations or precautions to discontinue WCT. Interestingly, WCT has solid scientific and medical bases (Taibah mechanism) that explain its effectiveness in treating many disease conditions differing in etiology and pathogenesis. WCT utilizes an excretory physiological principle (pressure-dependent excretion) that resembles excretion through renal glomerular filtration and abscess evacuation. WCT exhibits a percutaneous excretory function that clears blood (through fenestrated skin capillaries) and interstitial fluids from pathological substances without adding a metabolic or detoxification burden on the liver and the kidneys. Interestingly, WCT was reported to decrease serum ferritin (circulating iron stores) significantly by about 22.25% in healthy subjects (in one session) and to decrease serum iron significantly to the level of causing iron deficiency (in multiple sessions). WCT was reported to clear blood significantly of triglycerides, low-density lipoprotein (LDL) cholesterol, total cholesterol, uric acid, inflammatory mediators, and immunoglobulin antibodies (rheumatoid factor). Moreover, WCT was reported to enhance the natural immunity, potentiate pharmacological treatments, and to treat many different disease conditions. There are two distinct methods of WCT: traditional WCT and Al-hijamah (WCT of prophetic medicine). Both start and end with skin sterilization. In traditional WCT, there are two steps, skin scarification followed by suction using plastic cups (double S technique); Al-hijamah is a three-step procedure that includes skin suction using cups, scarification (shartat mihjam in Arabic), and second skin suction (triple S technique). Al-hijamah is a more comprehensive technique and does better than traditional WCT, as Al-hijamah includes two pressure-dependent filtration steps versus one step in traditional WCT. Whenever blood plasma is to be cleared of an excess pathological substance, Al-hijamah is indicated. We will discuss here some reported hematological and therapeutic benefits of Al-hijamah, its medical bases, methodologies, precautions, side effects, contraindications, quantitative evaluation, malpractice, combination with oral honey treatment, and to what extent it may be helpful when treating thalassemia and other conditions of iron overload and hyperferremia. PMID:25382989
The generation of side force by distributed suction
NASA Technical Reports Server (NTRS)
Roberts, Leonard; Hong, John
1993-01-01
This report provides an approximate analysis of the generation of side force on a cylinder placed horizontal to the flow direction by the application of distributed suction on the rearward side of the cylinder. Relationships are derived between the side force coefficients and the required suction coefficients necessary to maintain attached flow on one side of the cylinder, thereby inducing circulation around the cylinder and a corresponding side force.
Use of Suction Piles for Mooring of Mobile Offshore Bases.
1998-06-11
This procedure did not, however, take into account the passive suction developed by the pile. Investigation of soil interaction with suction piles...resulting o’^ distribution, which accounts for friction, is also shown in Fig. 5. The effective vertical stress profile within the clay just before the... accounting for active/passive soil pressures and skirt friction components. The principles used by Bye and his colleagues in the stability calculation
A Report on Deliverable Three: Determine a Standard Performance Test for Military Suction Device Use
2017-09-20
prehospital combat casualty care have unique performance requirements and should be tested in a manner that effectively simulates the anticipated...artificial airway or assisted ventilation . Loss of patient airway in tactical and combat environments commonly occurs. The proximate cause can be...points related to avoidance of adverse effects in the performance of suction: There are no contraindications to suctioning, however prolonged
Wang, Yu; Koenig, Steven C; Slaughter, Mark S; Giridharan, Guruprasad A
2015-01-01
The risk for left ventricular (LV) suction during left ventricular assist devices (LVAD) support has been a clinical concern. Current development efforts suggest LVAD suction prevention and physiologic control algorithms may require chronic implantation of pressure or flow sensors, which can be unreliable because of baseline drift and short lifespan. To overcome this limitation, we designed a sensorless suction prevention and physiologic control (eSPPC) algorithm that only requires LVAD intrinsic parameters (pump speed and power). Two gain-scheduled, proportional-integral controllers maintain a differential pump speed (ΔRPM) above a user-defined threshold to prevent LV suction while maintaining an average reference differential pressure (ΔP) between the LV and aorta. ΔRPM is calculated from noisy pump speed measurements that are low-pass filtered, and ΔP is estimated using an extended Kalman filter. Efficacy and robustness of the eSPPC algorithm were evaluated in silico during simulated rest and exercise test conditions for 1) excessive ΔP setpoint (ES); 2) rapid eightfold increase in pulmonary vascular resistance (PVR); and 3) ES and PVR. Simulated hemodynamic waveforms (LV pressure and volume; aortic pressure and flow) using only intrinsic pump parameters showed the feasibility of our proposed eSPPC algorithm in preventing LV suction for all test conditions.
Oil cooled, hermetic refrigerant compressor
English, William A.; Young, Robert R.
1985-01-01
A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.
Oil cooled, hermetic refrigerant compressor
English, W.A.; Young, R.R.
1985-05-14
A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.
NASA Astrophysics Data System (ADS)
Hopfgartner, J.; Posch, S.; Zuber, B.; Almbauer, R.; Krischan, K.; Stangl, S.
2017-08-01
Reed valves are widely used in hermetic reciprocating compressors and are responsible for a large part of the thermodynamic losses. Especially, the suction valve, which is opened nearly during the whole suction stroke, has a big potential for improvement. Usually, suction valves are opened only by vacuum created by the moving piston and should be closed before the compression stroke starts to avoid a reversed mass-flow through the valve. Therefore, the valves are prestressed, which results on the other hand in a higher flow resistance. In this work, a suction valve is investigated, which is not closed by the preload of the valve but by an electromagnetic coil located in the suction muffler neck. Shortly before the piston reaches its bottom dead centre, voltage is applied to the coil and a magnetic force is generated which pulls the valve shut. Thereby, the flow resistance through the valve can be reduced by changing the preload on the reed valve because it is no longer needed to close the valve. The investigation of this adapted valve and the electromagnetic coil is firstly done by numerical simulations including fluid structure interactions of the reed valves of a reciprocating compressor and secondly by experiments made on a calorimeter test bench.
Van Wassenbergh, Sam; Lieben, Tim; Herrel, Anthony; Huysentruyt, Frank; Geerinckx, Tom; Adriaens, Dominique; Aerts, Peter
2009-01-01
Food scraping has independently evolved twice from suction feeding in the evolution of catfishes: within neotropical Loricarioidea and paleotropical Mochokidae. To gain insight in the evolutionary transitions associated with the evolution towards scraping, we analyzed prey capture kinematics in two species of benthic suction feeders which belong to taxa that are closely related to the scraper lineages (respectively, Corydoras splendens and Synodontis multipunctatus), and compared it to prey capture in a more distantly related, generalist suction feeder (Clarias gariepinus). Simultaneous ventral and lateral view high-speed videos were recorded to quantify the movements of the lower jaw, hyoid, pectoral girdle and neurocranium. Additionally, ellipse modeling was applied to relate head shape differences to buccal expansion kinematics. Similarly to what has been observed in scrapers, rotations of the neurocranium are minimal in the benthic suction feeders, and may consequently have facilitated the evolution of a scraping feeding mechanism. The hypothesis that fish with a more laterally compressed head rely more heavily on lateral expansion of the buccal cavity to generate suction, was confirmed in our sample of catfish species. Since an important contribution of lateral expansion of the head to suction may avoid the need for a strong, ventral depression of the mouth floor during feeding, we hypothesized that this may have allowed a closer association with the substrate in the ancestors of scrapers. However, our hypothesis was not supported by an ancestral state reconstruction, which suggests that scraping probably evolved from sub-terminal mouthed ancestors with dorsoventrally flattened heads.
Strain localization in usnaturated soils with large deformation
NASA Astrophysics Data System (ADS)
Song, X.; Borja, R. I.
2014-12-01
Strain localization is a ubiquitous feature of granular materials undergoing nonhomogeneous deformation. In unsaturated porous media, how the localized deformation band is formed depends crucially on the degree of saturation, since fluid in the pores of a solid imposes a volume constraint on the deformation of the solid. When fluid flow is involved, the inception of the localized deformation band also depends on the heterogeneity of a material, which is quantified in terms of the spatial variation of density, the degree of saturation, and matric suction. We present a mathematical framework for coupled solid-deformation/fluid-diffusion in unsaturated porous media that takes into account material and geometric nonlinearities [1, 2]. The framework relies on the continuum principle of thermodynamics to identify an effective, or constitutive, stress for the solid matrix, and a water retention law that highlights the interdependence of degree of saturation, suction, and porosity of the material. We discuss the role of heterogeneity, quantified either deterministically or stochastically, on the development of a persistent shear band. We derive bifurcation conditions [3] governing the initiation of such a shear band. This research is inspired by current testing techniques that allow nondestructive and non-invasive measurement of density and the degree of saturation through high-resolution imaging [4]. The numerical simulations under plane strain condition demonstrate that the bifurcation not only manifests itself on the loading response curve and but also in the space of the degree of saturation, specific volume and suction stress. References[1] Song X, Borja RI, Mathematical framework for unsaturated flow in the finite deformation range. Int. J. Numer. Meth. Engng 2014; 97: 658-686. [2] Song X, Borja RI, Finite deformation and fluid flow in unsaturated soils with random heterogeneity. Vadose Zone Journal 2014; doi:10.2136/vzj2013.07.0131. [3] Song X, Borja RI, Instability and bifurcation in partially saturated porous media. 2014. to be submitted. [4] Song X, Strain localization in unsaturated porous media. 2014. Ph.D. Dissertation, Stanford University, California.
Frequency-dependent baroreflex control of blood pressure and heart rate during physical exercise.
Spadacini, Giammario; Passino, Claudio; Leuzzi, Stefano; Valle, Felice; Piepoli, Massimo; Calciati, Alessandro; Sleight, Peter; Bernardi, Luciano
2006-02-15
It is widely recognised that during exercise vagal heart rate control is markedly impaired but blood pressure control may or may not be retained. We hypothesised that this uncertainty arose from the differing responses of the vagus (fast) and sympathetic (slow) arms of the autonomic effectors, and to differing sympatho-vagal balance at different exercise intensities. We studied 12 normals at rest, during moderate (50% maximal heart rate) and submaximal (80% maximal heart rate) exercise. The carotid baroreceptors were stimulated by sinusoidal neck suction at the frequency of the spontaneous high- (during moderate exercise) and low-frequency (during submaximal) fluctuations in heart period and blood pressure. The increases in these oscillations induced by neck suction were measured by autoregressive spectral analysis. At rest neck stimulation increased variability at low frequency (RR: from 6.99+/-0.24 to 8.87+/-0.18 ln-ms2; systolic pressure: from 3.05+/-1.7 to 4.09+/-0.17 ln-mm Hg2) and high frequency (RR: from 4.67+/-0.25 to 6.79+/-0.31 ln-ms2; systolic pressure: from 1.93+/-0.2 to 2.67+/-0.125 ln-mm Hg2) (all p<0.001). During submaximal exercise RR variability decreased but systolic pressure variability rose (p<0.01 vs rest); during submaximal exercise low-frequency neck stimulation increased the low-frequency fluctuations in blood pressure (2.35+/-0.51 to 4.25+/-0.38 ln-mm Hg2, p<0.05) and RR. Conversely, neck suction at high frequency was ineffective on systolic pressure, and had only minor effects on RR interval during moderate exercise. During exercise baroreflex control is active on blood pressure, but the efferent response on blood pressure and heart rate is only detected during low frequency stimulation, indicating a frequency-dependent effect.
Linearized propulsion theory of flapping airfoils revisited
NASA Astrophysics Data System (ADS)
Fernandez-Feria, Ramon
2016-11-01
A vortical impulse theory is used to compute the thrust of a plunging and pitching airfoil in forward flight within the framework of linear potential flow theory. The result is significantly different from the classical one of Garrick that considered the leading-edge suction and the projection in the flight direction of the pressure force. By taking into account the complete vorticity distribution on the airfoil and the wake the mean thrust coefficient contains a new term that generalizes the leading-edge suction term and depends on Theodorsen function C (k) and on a new complex function C1 (k) of the reduced frequency k. The main qualitative difference with Garrick's theory is that the propulsive efficiency tends to zero as the reduced frequency increases to infinity (as 1 / k), in contrast to Garrick's efficiency that tends to a constant (1 / 2). Consequently, for pure pitching and combined pitching and plunging motions, the maximum of the propulsive efficiency is not reached as k -> ∞ like in Garrick's theory, but at a finite value of the reduced frequency that depends on the remaining non-dimensional parameters. The present analytical results are in good agreement with experimental data and numerical results for small amplitude oscillations. Supported by the Ministerio de Economia y Competitividad of Spain Grant No. DPI2013-40479-P.
[Preliminary evaluation of the femtosecond laser-assisted cataract surgery in 300 cases].
Wang, Yong; Bao, Xianyi; Zhou, Yanli; Xu, Rong; Peng, Tingting; Sun, Ming; Cao, Danmin; He, Ling
2015-09-01
To evaluate the clinical outcome of the femtosecond laser-assisted cataract surgery (FLACS) in our first 300 cases. In this retrospective study, the study group comprised 300 cases (300 eyes) in which FLACS was done. The control group comprised 300 cases (300 eyes) in which phacoemulsification was performed. The steps of the FLACS included capsulotomy, lens fragmentation, corneal incisions, and creation of incisions within the peripheral cornea to aid the correction of pre-existing astigmatism. After the FLACS, 2.2-mm coaxial micro-incision phacoemulsification and implantation of an intraocular lens were operated. The preoperative best corrected visual acuity (BCVA) and postoperative uncorrected visual acuity (UCVA), the cumulative dissipated energy (CDE) of the phacoemulsification, and the parameters of the FLACS, including the docking time, the suction time and the laser time, were recorded. The complications of the FLACS were analyzed. The FLACS was successfully completed in 99.33% of the cases. The docking time was (24.6 ± 16.8) sec, the suction time was (101.27 ± 20.09) sec, and the laser time was (23.3 ± 5.5) sec. The most common complications of the FLACS included suction break (7/300, 2.33%), subconjunctival hemorrhage (58/300, 19.33%), pupillary constriction (47/300, 15.67%), incision at a wrong site (13/300, 4.33%), anterior capsular tag (17/300, 5.67%), decentration of the capsulorhexis (11/300, 3.67%), failure to split the lens nucleus (5/300, 1.67%), and posterior capsular ruptures (1/300, 0.33%). The CDE was 5.52 ± 5.18 in the FLACS group and 8.37 ± 7.91 in the traditional phaco group (P < 0.05). The UCVA was 0.12 ± 0.08 and 0.13 ± 0.11 at 1 month after the FLACS and traditional phaco, respectively (P > 0.05). Compared with the conventional phacoemulsification surgery, the FLACS can achieve less CDE and better early postoperative visual acuity. Long-term effects remain to be investigated.
Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...
Thomas, Margot; Fothergill-Bourbonnais, Frances
2005-12-01
Making accurate and timely judgments based on multiple ways of knowing is an essential skill in critical care nursing practice. Studies have proposed that positive patient outcomes are linked to expert judgments in a variety of critical care situations; however, little is known about clinical judgments related to specific critical care nursing interventions. This article presents a qualitative nursing research study which examined the cues that expert pediatric critical care nurses used in making clinical judgments about suctioning intubated and ventilated, critically ill children. The participants' words and actions attest that the 'sensing' and 'thinking' of the process of cue use, are interwoven with, and integral to, the 'doing,' which is the process of skilled performance.
Lytvynets, A; Langrova, I; Lachout, J; Vadlejch, J
2013-01-01
Pinworms (Nematoda: Oxyurida) are common contaminants in most laboratory rodent colonies. The aim of the study was to monitor the transmission of Syphacia muris eggs in laboratory rat breeding facilities. Dust in a breeding room was investigated using special grids (free fallout, or through the help suction chamber). Furthermore, the ventilation system, breeding cages and the hands of the laboratory technical staff were examined. In the case of free fallout, the percentage of positive grids increased slightly over time: from 5.5% (after 24 h) to 8.2% (72 h). Similar values were also found when using the suction chamber (7.6%). Many more pinworm eggs were found in samples collected every second month from suction holes of the ventilation system (28.7%). One-half of the samples taken from the breeding cages (before washing) exhibited pinworm eggs (50.8%). Examination of the hands of technical staff showed positive detection in 37.9% of cases. In this study, certain transmission factors (dust, unclean cages and technicians) were proved to be significant in the distribution of pinworm infection in laboratory rodent facilities.
Suction muffler for refrigeration compressor
Nelson, R.T.; Middleton, M.G.
1983-01-25
A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.
Suction muffler for refrigeration compressor
Nelson, Richard T.; Middleton, Marc G.
1983-01-01
A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell.
Turbine blades and systems with forward blowing slots
Zuteck, Michael D.; Zalusky, Leigh; Lees, Paul
2015-09-15
A blade for use in a wind turbine comprises a pressure side and suction side meeting at a trailing edge and leading edge. The pressure side and suction side provide lift to the turbine blade upon the flow of air from the leading edge to the trailing edge and over the pressure side and suction side. The blade includes one or more openings at the suction side, in some cases between the leading edge and the trailing edge. The one or more openings are configured to provide a pressurized fluid towards the leading edge of the blade, in some cases at an angle between about 0.degree. and 70.degree. with respect to an axis oriented from a centerline of the blade toward the leading edge.
Tube thorocostomy: management and outcome in patients with penetrating chest trauma.
Muslim, Muhammad; Bilal, Amer; Salim, Muhammad; Khan, Muhammad Abid; Baseer, Abdul; Ahmed, Manzoor
2008-01-01
Penetrating chest trauma is common in this part of the world due to present situation in tribal areas. The first line of management after resuscitation in these patients is tube thoracostomy combined with analgesia and incentive spirometry. After tube thoracostomy following surgery or trauma there are two schools of thought one favours application of continuous low pressure suction to the chest tubes beyond the water seal while other are against it. We studied the application of continuous low pressure suction in patients with penetrating chest trauma. This Randomized clinical controlled trial was conducted in the department of thoracic surgery Post Graduate Medical Institute Lady Reading Hospital Peshawar from July 2007 to March 2008. The objectives of study were to evaluate the effectiveness of continuous low pressure suction in patients with penetrating chest trauma for evacuation of blood, expansion of lung and prevention of clotted Haemothorax. One hundred patients who underwent tube thoracostomy after penetrating chest trauma from fire arm injury or stab wounds were included in the study. Patients with multiple trauma, blunt chest trauma and those intubated for any pulmonary or pleural disease were excluded from the study. After resuscitation, detailed examination and necessary investigations patients were randomized to two groups. Group I included patients who had continuous low pressure suction applied to their chest drains. Group II included those patients whose chest drains were placed on water seal only. Lung expansion development of pneumothorax or clotted Haemothorax, time to removal of chest drain and hospital stay was noted in each group. There were fifty patients in each group. The two groups were not significantly different from each other regarding age, sex, pre-intubation haemoglobin and pre intubation nutritional status. Full lung expansion was achieved in forty six (92%) patients in group I and thirty seven (74%) in group II. Partial lung expansion or pneumothorax was present in three (60%) in group I and 10 (20%) in group II. One patient in group I and three (6%) patients in group II had no response. The mean time to removal of chest drains were 8.2 +/- 3.14 days in group I and 12.6 +/- 4.20 days in group II. The length of hospital stay was 7.2 +/- 2.07 days and 12.4 +/- 3.63 days in group I and II respectively. Clotted Haemothorax requiring surgery developed in three (6%) patients in group I and 8 (16%) patients in group II. Placing chest tubes on continuous low pressure suction after penetrating chest trauma helps evacuation of blood, expansion of lung and prevents the development of clotted Haemothorax. It also reduces the time to removal of chest drains, the hospital stay and the chances of surgery for clotted Haemothorax or Empyema.
The influence of total suction on the brittle failure characteristics of clay shales
NASA Astrophysics Data System (ADS)
Amann, F.; Linda, W.; Zimmer, S.; Thoeny, R.
2013-12-01
Clay shale testing is challenging and the results obtained from standard laboratory tests may not always reflect the strength of the clay shale in-situ. This is to a certain extend associated with the sensitivity of these rock types to desaturation processes during drilling, sample storage, and sample preparation. In this study the relationship between total suction, uniaxial compressive strength and Brazilian tensile (BTS) strength of cylindrical samples of Opalinus Clay was established in a systematic manner. Unconfined uniaxial compression and BTS tests were performed utilizing a servo-controlled testing procedure. Total suctions in the specimens was generated in air tight desiccators using supersaturated saline solutions which establish a relative humidity ranging from 20% to 99%. For unconfined compressive strength tests loading of the specimens occurred parallel to bedding. For BTS tests loading was either oriented normal or perpendicular to bedding. Both, the crack initiation and volumetric strain reversal threshold values were determined using volumetric and radial stress-strain methods. The results of BTS tests show that the tensile strength normal and perpendicular to bedding increases by a factor of approximately 3 when total suction is increased from 0 to 90 MPa (i.e. saturation decreases from 1.0 to 0.7) . Beyond 90 MPa total suction no further increase in tensile strength was observed, most probably due to shrinkage cracks which alter the tensile strength of the clay shale. Results obtained from UCS tests suggest that higher total suctions result in higher UCS values. Between total suctions of 0 to 90 MPa, the strength increase is almost linear (i.e. the UCS increases by a factor of 1.5 MPa). Beyond 90 MPa total suction no further strength increase was observed. A similar trend can be observed for crack initiation and crack damage values. In the same range of total suction the crack initiation stress increases by a factor of 5 (from 2 MPa to 10 MPa), and the crack damage stress increases by a factor of 2 (from 6 to 12 MPa). In addition to UCS tests, the water retention curve of intact and disturbed specimens was established. Here, results indicate that the drying path remains nearly unaffected by mechanical damage. However, the wetting path is considerably affected by mechanical damage.
Takano, Kenichi; Kurose, Makoto; Mitsuzawa, Hiroaki; Nagaya, Tomonori; Himi, Tetsuo
2015-01-01
Tracheoesophageal diversion (TED) and laryngotracheal separation (LTS) can prevent aspiration pneumonia and improve the morbidity of patients with severe motor and intellectual disability (SMID). By improving hospitalization rates and care needs, the quality-of-life can be improved for the patients and their parents. This study evaluated the clinical outcomes of TED and LTS in patients with intractable aspiration and SMID. This study retrospectively reviewed patients with SMID and intractable aspiration pneumonia who underwent TED or LTS at the institution between January 2008 and January 2015. It assessed the frequency of sputum suctioning, the number of pre-operative and post-operative hospitalizations, the operative time, and complications. Forty patients were identified during the study period. After surgery, there were significant reductions in the frequency of secretion suctioning (from 165.0 times/day to 33.0 times/day) and the number of hospitalizations because of aspiration pneumonia (from 5.4 times/year to 0.2 times/year). A tracheocutaneous fistula occurred in one (2.5%) patient, and two (5.4%) patients developed tracheoinnominate artery fistulas. In the latter group, the innominate arteries were successfully ligated and endovascular embolization was performed.
Thoracic irrigation prevents retained hemothorax: a pilot study.
Kugler, Nathan W; Carver, Thomas W; Paul, Jasmeet S
2016-05-15
Upward of 20% of patients undergoing thoracostomy tube (TT) placement develop retained hemothorax (HTx) requiring secondary intervention. The aim of this study was to define the rate of secondary intervention in patients undergoing prophylactic thoracic irrigation. A prospective observational trial of 20 patients who underwent thoracic irrigation at the time of TT placement was conducted. Patients with HTx identified on chest x-ray were included. After standard placement of a 36-French TT, the HTx was evacuated using a sterile suction catheter advanced within the TT. Warmed sterile saline was instilled into the chest through the TT followed by suction catheter evacuation. The TT was connected to the sterile drainage atrium and suction applied. TTs were managed in accordance with our standard division protocol. The population was predominantly (70%) male at median age 35 years, median ISS 13, with 55% suffering penetrating trauma. Thirteen (65%) patients underwent TT placement within 6 h of trauma with the remainder within 24 h. Nineteen patients received the full 1000-mL irrigation. The majority demonstrated significant improvement on postprocedure chest x-ray. The secondary intervention rate was 5%. A single patient required VATS on post-trauma day zero for retained HTx. Median TT duration was 5 d with median length of stay of 7 d. No adverse events related to the pleural lavage were noted. Thoracic irrigation at the time of TT placement for traumatic HTx may decrease the rate of retained HTx. Copyright © 2016 Elsevier Inc. All rights reserved.
Yaniv, Sarit; Elad, David; Holzman, Roi
2014-10-15
Suction feeding is thought to be the primary mode of prey capture in most larval fishes. Similar to adult suction feeders, larvae swim towards their prey while rapidly expanding their mouth cavity to generate an inward flow of water that draws the prey into the mouth. Although larvae are known to experience flows with lower Reynolds numbers than adults, it is unclear how the suction-induced flow field changes throughout ontogeny, and how such changes relate to prey capture performance. To address these questions, we determined mouth dimensions and opening speeds in Sparus aurata from first-feeding larvae to adults. We proceeded to develop a computational model of mouth expansion in order to analyze the scaling of suction flows under the observed parameters. Larval fish produced suction flows that were around two orders of magnitude slower than those of adults. Compared with adult fish, in which flow speed decays steeply with distance in front of the mouth, flow speed decayed more gradually in larval fish. This difference indicates that viscous forces in low Reynolds number flows modify the spatial distribution flow speed in front of the mouth. Consequently, simulated predator-prey encounters showed that larval fish could capture inert prey from a greater distance compared with adults. However, if prey attempted to escape then larval fish performed poorly: simulations inferred capture success in only weakly escaping prey immediately in front of the mouth. These ontogenetic changes in Reynolds number, suction-induced flow field and feeding performance could explain a widespread ontogenetic diet shift from passive prey at early life stages to evasive prey as larvae mature. © 2014. Published by The Company of Biologists Ltd.
Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv
2016-01-01
Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.
Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler
2015-05-07
To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wittmann, F W; Ring, P A
1984-01-01
In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978
NASA Technical Reports Server (NTRS)
Forgoston, Eric; Tumin, Anatoli; Ashpis, David E.
2005-01-01
An analysis of the optimal control by blowing and suction in order to generate stream- wise velocity streaks is presented. The problem is examined using an iterative process that employs the Parabolized Stability Equations for an incompressible uid along with its adjoint equations. In particular, distributions of blowing and suction are computed for both the normal and tangential velocity perturbations for various choices of parameters.
NASA Technical Reports Server (NTRS)
Bassom, Andrew P.; Seddougui, Sharon O.
1991-01-01
There exist two types of stationary instability of the flow over a rotating disc corresponding to the upper branch, inviscid mode and the lower branch mode, which has a triple deck structure, of the neutral stability curve. A theoretical study of the linear problem and an account of the weakly nonlinear properties of the lower branch modes have been undertaken by Hall and MacKerrell respectively. Motivated by recent reports of experimental sightings of the lower branch mode and an examination of the role of suction on the linear stability properties of the flow here, the effects are studied of suction on the nonlinear disturbance described by MacKerrell. The additional analysis required in order to incorporate suction is relatively straightforward and enables the derivation of an amplitude equation which describes the evolution of the mode. For each value of the suction, a threshold value of the disturbance amplitude is obtained; modes of size greater than this threshold grow without limit as they develop away from the point of neutral stability.
Suction is kid's play: extremely fast suction in newborn seahorses.
Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony
2009-04-23
Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids.
Suction is kid's play: extremely fast suction in newborn seahorses
Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony
2009-01-01
Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids. PMID:19324657
Observation of the spiral flow and vortex induced by a suction pump in superfluid 4He
NASA Astrophysics Data System (ADS)
Yano, H.; Ohyama, K.; Obara, K.; Ishikawa, O.
2018-03-01
A suction flow generates a whirlpool, namely a bathtub vortex, in a classical fluid; in contrast, rotating containers, which are usually used for studies of superfluid helium, can produce only simple solid rotation. In the present work, the superfluid flow and concentrated quantized vortices induced by a cryogenic motor immersed in superfluid 4He were investigated. Using a motor with six blades in a cylinder caused the free surface of the superfluid 4He to take on a parabolic shape, indicating that the motor produces a rotating superfluid flow. To drive a suction flow in superfluid helium, the motor was mounted in a cylindrical container with a small hole at the center of the top and a slit at the side, acting as a superfluid pump. This pump was successfully used to generate a spiral flow and a vortex with a funnel-shaped core in superfluid 4He, suggesting that the resulting suction flow transports and centralizes quantized vortices to the suction hole, increasing the vortex circulation and sucking the free surface of the superfluid down.
NASA Astrophysics Data System (ADS)
Dastagiri Babu, D.; Venkateswarlu, S.; Keshava Reddy, E.
2017-08-01
In this paper, we have considered the unsteady free convective two dimensional flow of a viscous incompressible electrically conducting second grade fluid over an infinite vertical porous plate under the influence of uniform transverse magnetic field with time dependent permeability, oscillatory suction. The governing equations of the flow field are solved by a regular perturbation method for small amplitude of the permeability. The closed form solutions for the velocity, temperature and concentration have been derived analytically and also its behavior is computationally discussed with reference to different flow parameters with the help of profiles. The skin fiction on the boundary, the heat flux in terms of the Nusselt number and rate of mass transfer in terms of Sherwood number are also obtained and their behavior computationally discussed.
Enhancing the performance of the domestic refrigerator with hot gas injection to suction line
NASA Astrophysics Data System (ADS)
Berman, E. T.; Hasan, S.; Mutaufiq
2016-04-01
The purpose of this study was to determine the increase in performance of a domestic refrigerator that uses hot gas injection (IHG) to the suction line. The experiment was conducted by flowing refrigerant from the discharge line to the suction line. To get performance data, measurements performed on the liquid brine as cooling load with various temperatures (range from 3°C to - 3°C). The working fluid is used as a cooling medium is R-134a. The experimental results showed that the injection of hot gas to the suction line generates an increase in the coefficient of performance systems (COPs) of 7% and is able to lower the discharge temperature, causing the compressor to work lighter/easier, saving electric power needed by the refrigerator.
Effects of wall suction/blowing on two-dimensional flow past a confined square cylinder.
Zhang, Wei; Jiang, Yanqun; Li, Lang; Chen, Guoping
2016-01-01
A numerical simulation is conducted to study the laminar flow past a square cylinder confined in a channel (the ratio of side length of the square to channel width is fixed at 1/4) subjected to a locally uniform blowing/suction speed placed at the top and bottom channel walls. Governing equations with boundary conditions are resolved using a finite volume method in pressure-velocity formulation. The flow patterns relevant to the critical spacing values are investigated. Numerical results show that wall blowing has a stabilizing effect on the flow, and the corresponding critical Reynolds number increases monotonically with increasing blowing velocity. Remarkably, steady asymmetric solutions and hysteretic mode transitions exist in a certain range of parameters (Reynolds number and suction speed) in the case of suction.
NASA Technical Reports Server (NTRS)
Turriziani, R. V.; Lovell, W. A.; Price, J. E.; Quartero, C. B.; Washburn, S. F.
1979-01-01
Two aircraft were evaluated, using a derated TF34-GE-100 turbofan engine one with laminar flow control (LFC) and one without. The mission of the remotely piloted vehicles (RPV) is one of high-altitude loiter at maximum endurance. With the LFC system maximum mission time increased by 6.7 percent, L/D in the loiter phase improved 14.2 percent, and the minimum parasite drag of the wing was reduced by 65 percent resulting in a 37 percent reduction for the total airplane. Except for the minimum parasite drag of the wing, the preceding benefits include the offsetting effects of weight increase, suction power requirements, and drag of the wing-mounted suction pods. In a supplementary study using a scaled-down, rather than derated, version of the engine, on the LFC configuration, a 17.6 percent increase in mission time over the airplane without LFC and an incremental time increase of 10.2 percent over the LFC airplane with derated engine were attained. This improvement was due principally to reductions in both weight and drag of the scaled engine.
Remotely operated submersible underwater suction apparatus
Kristan, Louis L.
1990-01-01
A completely submersible, remotely operated underwater suction device for collection of irradiated materials in a nuclear pool is disclosed. The device includes a pump means for pumping water through the device, a filter means for capturing irradiated debris, remotely operated releasable connector means, a collection means and a means for remotely maneuvering the collection means. The components of the suction device may be changed and replaced underwater to take advantage of the excellent radiation shielding ability of water to thereby minimize exposure of personnel to radiation.
A perspective of laminar-flow control. [aircraft energy efficiency program
NASA Technical Reports Server (NTRS)
Braslow, A. L.; Muraca, R. J.
1978-01-01
A historical review of the development of laminar flow control technology is presented with reference to active laminar boundary-layer control through suction, the use of multiple suction slots, wind-tunnel tests, continuous suction, and spanwise contamination. The ACEE laminar flow control program is outlined noting the development of three-dimensional boundary-layer codes, cruise-noise prediction techniques, airfoil development, and leading-edge region cleaning. Attention is given to glove flight tests and the fabrication and testing of wing box designs.
NASA Technical Reports Server (NTRS)
Lan, C. E.; Chang, J. F.
1981-01-01
A user's guide to an improved version of Woodward's chord plane aerodynamic panel computer code is presumed. The guide can be applied to cambered wings exhibiting edge separated flow, including those with leading edge vortex flow at subsonic and supersonic speeds. New orientations for the rotated suction force are employed based on the momentum principal. The supersonic suction analogy method is improved by using an effective angle of attack defined through a semiempirical method.
NASA Technical Reports Server (NTRS)
Juhasz, A.
1974-01-01
The performance of a short highly asymmetric annular diffuser equipped with wall bleed (suction) capability was evaluated at nominal inlet Mach numbers of 0.188, 0.264, and 0.324 with the inlet pressure and temperature at near ambient values. The diffuser had an area ratio of 2.75 and a length- to inlet-height ratio of 1.6. Results show that the radial profiles of diffuser exit velocity could be controlled from a severely hub peaked to a slightly tip biased form by selective use of bleed. At the same time, other performance parameters were also improved. These results indicate the possible application of the diffuser bleed technique to control flow profiles to gas turbine combustors.
Why Cannot Suction Drains Prevent Postoperative Spinal Epidural Hematoma?
Ahn, Dong Ki; Kim, Jin Woo; Yi, Seong Min
2016-01-01
Background Postoperative spinal epidural hematoma (POSEH) is different from spontaneous or post-spinal procedure hematoma because of the application of suction drains. However, it appeared that suction drains were not effective for prevention of POSEH in previous studies. The purpose of this study was to test our hypothesis that POSEH can be caused by hypercoagulability. Methods This was an experimental study. One hundred fifty milliliters of blood was donated from each of the 12 consecutive patients who underwent spine surgery and infused into 3 saline bags of 50 mL each. One of the 3 bags in each set contained 5,000 units of thrombin. All of them were connected to 120 ± 30 mmHg vacuum suctions: drainage was started 8 minutes after connection to the vacuum system for 12 normal blood bags (BV8) and 12 thrombin-containing blood bags (TBV8) and 15 minutes after connection for the remaining 12 normal blood bags (BV15). The amount of initial and remaining hematoma at 20 minutes, 120 minutes, and 24 hours after vacuum application were measured by their weight (g). The primary endpoint was the difference between BV8 and TBV8. The secondary end point was the difference between BV8 and BV15. Results The remaining hematoma in TBV8 was significantly greater than that in BV8 at all measurement points: 46.3 ± 12.4 vs. 17.0 ± 1.3 (p = 0.000) at 20 minutes; 33.0 ± 8.2 vs. 16.3 ± 1.2 (p = 0.000) at 120 minutes; and 26.1 ± 4.0 vs. 15.8 ± 1.6 (p = 0.000) at 24 hours after vacuum application. The remaining hematoma of BV15 was significantly greater than that of BV8 at all measurement points: 30.0 ± 12.0 vs. 17.0 ± 1.3 (p = 0.002) at 20 minutes; 24.2 ± 7.6 vs. 16.3 ± 1.2 at 120 minutes (p = 0.002); and 22.2 ± 6.6 vs. 15.8 ± 1.6 (p = 0.004) at 24 hours after vacuum application. Conclusions With a suction drain in place, the amount of remaining hematoma could be affected by coagulability. Thrombin-containing local hemostatics and the length of time elapsed before the commencement of suction resulted in hypercoagulability, indicating these two factors could be causes of POSEH. PMID:27904723
Suction-assisted liposuction with a y-connector.
Uysal, Cagri A; Coskun, Erhan; Ozkan, Burak; Cologlu, Harun; Borman, Huseyin
2012-12-01
Liposuction appears to be one of the simplest aesthetic techniques to date, and its popularity has spread worldwide. The authors have been using a Y-connector that enables two plastic surgeons to work at the same with the same suction-assisted liposuction (SAL) machine. For 12 patients whose liposuction procedures were performed using one-cannula SAL, the mean surgical time was 114 ± 10.8 min, whereas for 11 patients whose liposuction procedures were performed with Y-connector SAL, the mean surgical time was 62 ± 7.8 min. This difference between the two groups is statistically significant (p < 0.05). The authors believe the Y-connector may be a less tiring alternative for plastic surgeons who still think SAL is the gold standard for liposuction. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Animal experimental studies using small intestine endoscope
Liu, Jin-Hua; Liu, Dan-Yang; Wang, Li; Han, Li-Ping; Qi, Zhe-Yu; Ren, Hai-Jun; Feng, Yan; Luan, Feng-Ming; Mi, Liang-Tian; Shan, Shu-Mei
2017-01-01
AIM To assess the feasibility and safety of a novel enteroscope, negative-pressure suction endoscope in examining the small intestine of a porcine model. METHODS In vitro experiments in small intestinal loops from 20 pigs and in vivo experiments in 20 living pigs were conducted. RESULTS In in vitro experiments, a negative pressure of > 0.06 MPa was necessary for optimal visualization of the intestine, and this pressure did not cause gross or histological damage to the mucosa. For satisfactory examination of the small intestine in vivo, higher negative pressure (> 1.00 MPa) was required. Despite this higher pressure, the small intestine did not show any gross or microscopic damage in the suctioned areas. The average time of examination in the living animals was 60 ± 7.67 min. The animals did not experience any apparent ill effects from the procedure. CONCLUSION Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases. PMID:28611521
Healthcare-Wide Hazards: Surgical Suite
... smoke evacuators and room suction systems with inline filters. Keep the smoke evacuator or room suction hose ... all surgical or other procedures. Consider all tubing, filters, and absorbers as infectious waste and dispose of ...
78 FR 30872 - Marine Mammals; File Nos. 14451, 14353, and 13846
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-23
... recording, and underwater photo/videography. Suction cup tags are deployed on humpback whales. Minke whales..., collection of sloughed skin, photogrammetry, biopsy sampling, playback experiments, and/or suction cup and...
76 FR 542 - Marine Mammals; File No. 15616
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-05
... recording, biopsy sampling, tagging with barbed darts and suction cups, and collecting samples of marine... acoustically record (PI), biopsy sample (BS), attach barbed dart satellite tags (DT), and suction cup tags (ST...
78 FR 2955 - Marine Mammals; File Nos. 14451, 14353, and 13846
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-15
... photo/videography. Suction cup tags are deployed on humpback whales. Minke whales are approached for..., biopsy sampling, playback experiments, and/or suction cup and implant tagging of target whales. The...
Trailing edge cooling using angled impingement on surface enhanced with cast chevron arrangements
Lee, Ching-Pang; Heneveld, Benjamin E.; Brown, Glenn E.; Klinger, Jill
2015-05-26
A gas turbine engine component, including: a pressure side (12) having an interior surface (34); a suction side (14) having an interior surface (36); a trailing edge portion (30); and a plurality of suction side and pressure side impingement orifices (24) disposed in the trailing edge portion (30). Each suction side impingement orifice is configured to direct an impingement jet (48) at an acute angle (52) onto a target area (60) that encompasses a tip (140) of a chevron (122) within a chevron arrangement (120) formed in the suction side interior surface. Each pressure side impingement orifice is configured to direct an impingement jet at an acute angle onto an elongated target area that encompasses a tip of a chevron within a chevron arrangement formed in the pressure side interior surface.
Evaluation of prototype air/fluid separator for Space Station Freedom Health Maintenance Facility
NASA Technical Reports Server (NTRS)
Billica, Roger; Smith, Maureen; Murphy, Linda; Kizzee, Victor D.
1991-01-01
A prototype air/fluid separator suction apparatus proposed as a possible design for use with the Health Maintenance Facility aboard Space Station Freedom (SSF) was evaluated. A KC-135 parabolic flight test was performed for this purpose. The flights followed the standard 40 parabola profile with 20 to 25 seconds of near-zero gravity in each parabola. A protocol was prepared to evaluate the prototype device in several regulator modes (or suction force), using three fluids of varying viscosity, and using either continuous or intermittent suction. It was felt that a matrixed approach would best approximate the range of utilization anticipated for medical suction on SSF. The protocols were performed in one-gravity in a lab setting to familiarize the team with procedures and techniques. Identical steps were performed aboard the KC-135 during parabolic flight.
Near wall cooling for a highly tapered turbine blade
Liang, George [Palm City, FL
2011-03-08
A turbine blade having a pressure sidewall and a suction sidewall connected at chordally spaced leading and trailing edges to define a cooling cavity. Pressure and suction side inner walls extend radially within the cooling cavity and define pressure and suction side near wall chambers. A plurality of mid-chord channels extend radially from a radially intermediate location on the blade to a tip passage at the blade tip for connecting the pressure side and suction side near wall chambers in fluid communication with the tip passage. In addition, radially extending leading edge and trailing edge flow channels are located adjacent to the leading and trailing edges, respectively, and cooling fluid flows in a triple-pass serpentine path as it flows through the leading edge flow channel, the near wall chambers and the trailing edge flow channel.
Chung, Fen-Fang; Lin, Hui-Ling; Liu, Hsueh-Erh; Lien, Angela Shin-Yu; Hsiao, Hsiu-Feng; Chou, Lan-Ti; Wan, Gwo-Hwa
2015-01-01
The investigation of hospital air quality has been conducted in wards, ICUs, operating theaters, and public areas. Few studies have assessed air quality in respiratory care centers (RCCs), especially in mechanically ventilated patients with open suctioning. The RCC air quality indices (temperature, relative humidity, levels of CO2, total volatile organic compounds, particulate matter [PM], bacteria, and fungi) were monitored over 1 y. The air around the patient's head was sampled during open suctioning to examine the probability of bioaerosol exposure affecting health-care workers. This investigation found that the levels of indoor air pollutants (CO2, PM, bacteria, and fungi) were below the indoor air quality standard set by the Taiwan Environmental Protection Agency. Meanwhile, the levels of total volatile organic compounds sometimes exceeded the indoor air quality standard, particularly in August. The identified bacterial genera included Micrococcus species, Corynebacterium species, and Staphylococcus species, and the predominant fungal genera included yeast, Aspergillus species, Scopulariopsis species, and Trichoderma species. Additionally, airborne PM2.5, PM1, and bacteria were clearly raised during open suctioning in mechanically ventilated patients. This phenomenon demonstrated that open suctioning may increase the bacterial exposure risk of health-care workers. RCC air quality deserves long-term monitoring and evaluation. Health-care workers must implement self-protection strategies during open suctioning to ensure their occupational health and safety in health-care settings. Copyright © 2015 by Daedalus Enterprises.
Effect of nonzero surface admittance on receptivity and stability of compressible boundary layer
NASA Technical Reports Server (NTRS)
Choudhari, Meelan
1994-01-01
The effect of small-amplitude short-scale variations in surface admittance on the acoustic receptivity and stability of two-dimensional compressible boundary layers is examined. In the linearized limit, the two problems are shown to be related both physically and mathematically. This connection between the two problems is used, in conjunction with some previously reported receptivity results, to infer the modification of stability properties due to surface permeability. Numerical calculations are carried out for a self-similar flat-plate boundary layer at subsonic and low supersonic speeds. Variations in mean suction velocity at the perforated admittance surface can also induce receptivity to an acoustic wave. For a subsonic boundary layer, the dependence of admittance-induced receptivity on the acoustic-wave orientation is significantly different from that of the receptivity produced via mean suction variation. The admittance-induced receptivity is generally independent of the angle of acoustic incidence, except in a relatively narrow range of upstream-traveling waves for which the receptivity becomes weaker. However, this range of angles is precisely that for which the suction-induced receptivity tends to be large. At supersonic Mach numbers, the admittance-induced receptivity to slow acoustic models is relatively weaker than that in the case of the fast acoustic modes. We also find that purely real values for the surface admittance tend to have a destabilizing effect on the evolution of an instability wave over a slightly permeable surface. The limits on the validity of the linearized approximation are also assessed in one specific case.
Day, T; Wainwright, S P; Wilson-Barnett, J
2001-09-01
Endotracheal suctioning is a frequently performed procedure that has many associated risks and complications. It is imperative that nurses are aware of these risks and are able to practise according to current research recommendations. This study was designed to examine to what extent intensive care nurses' knowledge and practice of endotracheal suctioning is based on research evidence, to investigate the relationships between knowledge and practice, and to evaluate the effectiveness of a research-based teaching programme. This quasi-experimental study was a randomized, controlled, single-blinded comparison of two research-based teaching programmes, with 16 intensive care nurses, using non-participant observation and a self-report questionnaire. Initial baseline data revealed a low level of knowledge for many participants, which was also reflected in practice, as suctioning was performed against many of the research recommendations. Following teaching, significant improvements were seen in both knowledge and practice. Four weeks later these differences were generally sustained, and provide evidence of the effectiveness of the educational intervention. The study raised concern about all aspects of endotracheal suctioning and highlighted the need for changes in nursing practice, with clinical guidelines and focused practice-based education.
Choi, Hyuk Soon; Chun, Hoon Jai; Kim, Kyoung-Oh; Kim, Eun Sun; Keum, Bora; Jeen, Yoon-Tae; Lee, Hong Sik; Kim, Chang Duck
2016-01-01
Here, we report the first successful endoscopic resection of an exophytic gastrointestinal stromal tumor (GIST) using a novel perforation-free suction excavation technique. A 49-year-old woman presented for further management of a gastric subepithelial tumor on the lesser curvature of the lower body, originally detected via routine upper gastrointestinal endoscopy. Abdominal computed tomography and endoscopic ultrasound showed a 4-cm extraluminally protruding mass originating from the muscularis propria layer. The patient firmly refused surgical resection owing to potential cardiac problems, and informed consent was obtained for endoscopic removal. Careful dissection and suction of the tumor was repeated until successful extraction was achieved without serosal injury. We named this procedure the suction excavation technique. The tumor’s dimensions were 3.5 cm × 2.8 cm × 2.5 cm. The tumor was positive for C-KIT and CD34 by immunohistochemical staining. The mitotic count was 6/50 high-power fields. The patient was followed for 5 years without tumor recurrence. This case demonstrated the use of endoscopic resection of an exophytic GIST using the suction excavation technique as a potential therapy without surgical resection. PMID:27340363
Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu
2018-06-01
Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.
Influence of hydraulic hysteresis on the mechanical behavior of unsaturated soils and interfaces
NASA Astrophysics Data System (ADS)
Khoury, Charbel N.
Unsaturated soils are commonly widespread around the world, especially at shallow depths from the surface. The mechanical behavior of this near surface soil is influenced by the seasonal variations such as rainfall or drought, which in turn may have a detrimental effect on many structures (e.g. retaining walls, shallow foundations, mechanically stabilized earth walls, soil slopes, and pavements) in contact with it. Thus, in order to better understand this behavior, it is crucial to study the complex relationship between soil moisture content and matric suction (a stress state variable defined as pore air pressure minus pore water pressure) known as the Soil Water Characteristic Curve (SWCC). In addition, the influence of hydraulic hysteresis on the behavior of unsaturated soils, soil-structure interaction (i.e. rough and smooth steel interfaces, soil-geotextile interfaces) and pavement subgrade (depicted herein mainly by resilient modulus, Mr) was also studied. To this end, suction-controlled direct shear tests were performed on soils, rough and smooth steel interfaces and geotextile interface under drying (D) and wetting after drying (DW). The shearing behavior is examined in terms of the two stress state variables, matric suction and net normal stress. Results along the D and DW paths indicated that peak shear strength increased with suction and net normal stress; while in general, the post peak shear strength was not influenced by suction for rough interfaces and no consistent trend was observed for soils and soil-geotextiles interfaces. Contrary to saturated soils, results during shearing at higher suction values (i.e. 25 kPa and above) showed a decrease in water content eventhough the sample exhibited dilation. A behavior postulated to be related to disruption of menisci and/or non-uniformity of pore size which results in an increase in localized pore water pressures. Interestingly, wetting after drying (DW) test results showed higher peak and post peak shear strength than that of the drying (D) tests. This is believed to be the result of many factors such as: (1) cyclic suction stress loading, (2) water content (less on wetting than drying), and (3) type of soil. The cyclic suction loading may have induced irrecoverable plastic strains, resulting in stiffer samples for wetting tests as compared to drying. Additionally, water may be acting as a lubricant and thus resulting in lower shear strength for test samples D with higher water contents than DW samples. Furthermore, various shear strength models were investigated for their applicability to the experimental data. Models were proposed for the prediction of shear strength with suction based on the SWCC. The models are able to predict the shear strength of unsaturated soil and interfaces due to drying and wetting (i.e. hydraulic hysteresis) by relating directly to the SWCC. The proposed models were used and partly validated by predicting different test results from the literature. In addition, an existing elastoplastic constitutive model was investigated and validated by comparing the predicted and experimental (stress-displacement, volume change behavior) results obtained from rough and geotextile interface tests. This study also explores the effect of hydraulic hysteresis on the resilient modulus (Mr) of subgrade soils. Suction-controlled Mr tests were performed on compacted samples along the primary drying, wetting, secondary drying and wetting paths. Two test types were performed to check the effect of cyclic deviatoric stress loading on the results. First, M r tests were performed on the same sample at each suction (i.e. 25, 50, 75, 100 kPa) value along all the paths (drying, wetting etc.). A relationship between resilient modulus (Mr) and matric suction was obtained and identified as the resilient modulus characteristic curve (MRCC). MRCC results indicated that Mr increased with suction along the drying curve. On the other hand, results on the primary wetting indicated higher Mr than that of the primary drying and the secondary drying. The second type of test was performed at selected suction without subjecting the sample to previous Mr tests. Results indicated that Mr compared favorably with the other type of test (i.e. with previous M r testing), which indicates that the cyclic deviatoric stress loading influence was not as significant as the hydraulic hysteresis (i.e. cyclic suction stress loading). A new model to predict the MRCC results during drying and wetting (i.e., hydraulic hysteresis) is proposed based on the SWCC hysteresis. The model predicted favorably the drying and then the wetting results using the SWCC at all stress levels. (Abstract shortened by UMI.)
21 CFR 884.1175 - Endometrial suction curette and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... uterus by scraping and vacuum suction. This device is used to obtain tissue for biopsy or for menstrual extraction. This generic type of device may include catheters, syringes, and tissue filters or traps. (b...
21 CFR 884.1175 - Endometrial suction curette and accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
... uterus by scraping and vacuum suction. This device is used to obtain tissue for biopsy or for menstrual extraction. This generic type of device may include catheters, syringes, and tissue filters or traps. (b...
Kabala, Cezary; Karczewska, Anna; Gałka, Bernard; Cuske, Mateusz; Sowiński, Józef
2017-07-01
The aims of the study were to analyse the concentration of nitrate and ammonium ions in soil solutions obtained using MacroRhizon miniaturized composite suction cups under field conditions and to determine potential nitrogen leaching from soil fertilized with three types of fertilizers (standard urea, slow-release urea, and ammonium nitrate) at the doses of 90 and 180 kg ha -1 , applied once or divided into two rates. During a 3-year growing experiment with sugar sorghum, the concentration of nitrate and ammonium ions in soil solutions was the highest with standard urea fertilization and the lowest in variants fertilized with slow-release urea for most of the months of the growing season. Higher concentrations of both nitrogen forms were noted at the fertilizer dose of 180 kg ha -1 . One-time fertilization, at both doses, resulted in higher nitrate concentrations in June and July, while dividing the dose into two rates resulted in higher nitrate concentrations between August and November. The highest potential for nitrate leaching during the growing season was in July. The tests confirmed that the miniaturized suction cups MacroRhizon are highly useful for routine monitoring the concentration of nitrate and ammonium ions in soil solutions under field conditions.
Adaptive Suction and Blowing for Twin-Tail Buffet Control
NASA Technical Reports Server (NTRS)
Kandil, Osama A.; Yang, Zhi
1999-01-01
Adaptive active flow control for twin-tail buffet alleviation is investigated. The concept behind this technique is to place control ports on the tail outer and inner surfaces with flow suction or blowing applied through these ports in order to minimize the pressure difference across the tail. The suction or blowing volume flow rate from each port is proportional to the pressure difference across the tail at this location. A parametric study of the effects of the number and location of these ports on the buffet response is carried out. The computational model consists of a sharp-edged delta wing of aspect ratio one and swept-back flexible twin tail with taper ratio of 0.23. This complex multidisciplinary problem is solved sequentially using three sets of equations for the fluid flow, aeroelastic response and grid deformation, using a dynamic multi-block grid structure. The computational model is pitched at 30 deg angle of attack. The freestream Mach number and Reynolds number are 0.3 and 1.25 million, respectively. The model is investigated for the inboard position of the twin tails, which corresponds to a separation distance between the twin tails of 33% of the wing span. Comparison of the time history and power spectral density responses of the tails for various distributions of the control ports are presented and discussed.
Conceptual design for a laminar-flying-wing aircraft
NASA Astrophysics Data System (ADS)
Saeed, T. I.
The laminar-flying-wing aircraft appears to be an attractive long-term prospect for reducing the environmental impact of commercial aviation. In assessing its potential, a relatively straightforward initial step is the conceptual design of a version with restricted sweep angle. Such a design is the topic of this thesis. Subject to constraints, this research aims to; provide insight into the parameters affecting practical laminar-flow-control suction power requirements; identify a viable basic design specification; and, on the basis of this, an assessment of the fuel efficiency through a detailed conceptual design study. It is shown that there is a minimum power requirement independent of the suction system design, associated with the stagnation pressure loss in the boundary layer. This requirement increases with aerofoil section thickness, but depends only weakly on Mach number and (for a thick, lightly-loaded laminar flying wing) lift coefficient. Deviation from the optimal suction distribution, due to a practical chamber-based architecture, is found to have very little effect on the overall suction coefficient. In the spanwise direction, through suitable choice of chamber depth, the pressure drop due to frictional and inertial effects may be rendered negligible. Finally, it is found that the pressure drop from the aerofoil surface to the pump collector ducts determines the power penalty. To identify the viable basic design specification, a high-level exploration of the laminar flying wing design space is performed. The characteristics of the design are assessed as a function of three parameters: thickness-to-chord ratio, wingspan, and unit Reynolds number. A feasible specification, with 20% thickness-to-chord, 80 m span and a unit Reynolds number of 8 x 106 m-1, is identified; it corresponds to a 187 tonne aircraft which cruises at Mach 0.67 and altitude 22,500 ft, with lift coefficient 0.14. On the basis of this specification, a detailed conceptual design is undertaken. A 220-passenger laminar-flying-wing concept, propelled by three turboprop engines, with a cruise range of 9000 km is developed. The laminar flying wing proposed in this thesis falls short of the performance improvements expected of the concept, and is not worth the development effort.
Role of the membrane cortex in neutrophil deformation in small pipets.
Zhelev, D V; Needham, D; Hochmuth, R M
1994-01-01
The simplest model for a neutrophil in its "passive" state views the cell as consisting of a liquid-like cytoplasmic region surrounded by a membrane. The cell surface is in a state of isotropic contraction, which causes the cell to assume a spherical shape. This contraction is characterized by the cortical tension. The cortical tension shows a weak area dilation dependence, and it determines the elastic properties of the cell for small curvature deformations. At high curvature deformations in small pipets (with internal radii less than 1 micron), the measured critical suction pressure for cell flow into the pipet is larger than its estimate from the law of Laplace. A model is proposed where the region consisting of the cytoplasm membrane and the underlying cortex (having a finite thickness) is introduced at the cell surface. The mechanical properties of this region are characterized by the apparent cortical tension (defined as a free contraction energy per unit area) and the apparent bending modulus (introduced as a bending free energy per unit area) of its middle plane. The model predicts that for small curvature deformations (in pipets having radii larger than 1.2 microns) the role of the cortical thickness and the resistance for bending of the membrane-cortex complex is negligible. For high curvature deformations, they lead to elevated suction pressures above the values predicted from the law of Laplace. The existence of elevated suction pressures for pipets with radii from 1 micron down to 0.24 micron is found experimentally. The measured excess suction pressures cannot be explained only by the modified law of Laplace (for a cortex with finite thickness and negligible bending resistance), because it predicts unacceptable high cortical thicknesses (from 0.3 to 0.7 micron). It is concluded that the membrane-cortex complex has an apparent bending modulus from 1 x 10(-18) to 2 x 10(-18) J for a cortex with a thickness from 0.1 micron down to values much smaller than the radius of the smallest pipet (0.24 micron) used in this study. Images FIGURE 1 PMID:7948682
McCaughey, Conor; Tsakiropoulos, Panos
2018-06-07
The Nb-silicide-based alloy of near eutectic composition (at.%) Nb-21.1Si-8.3Ti-5.4Mo-4W-0.7Hf (alloy CM1) was studied in the cast and heat-treated (1500 °C/100 h) conditions. The alloy was produced in the form of buttons and bars using three different methods, namely arc-melting, arc-melting and suction casting, and optical floating zone (OFZ) melting. In the former two cases the alloy solidified in water-cooled copper crucibles. Buttons and suction-cast bars of different size, respectively of 10 g and 600 g weight and 6 mm and 8 mm diameter, were produced. The OFZ bars were grown at three different growth rates of 12, 60 and 150 mm/h. It was confirmed that the type of Nb₅Si₃ formed in the cast microstructures depended on the solidification conditions. The primary phase in the alloy CM1 was the βNb₅Si₃. The transformation of βNb₅Si₃ to αNb₅Si₃ had occurred in the as cast large size button and the OFZ bars grown at the three different growth rates, and after the heat treatment of the small size button and the suction-cast bars of the alloy. This transformation was accompanied by subgrain formation in Nb₅Si₃ and the precipitation of Nb ss in the large size as cast button and only by the precipitation of Nb ss in the cast OFZ bars. Subgrains and precipitation of Nb ss in αNb₅Si₃ was observed in the small size button and suction-cast bars after the heat treatment. Subgrains formed in αNb₅Si₃ after the heat treatment of the OFZ bars. The partitioning of solutes and in particular of Mo and Ti was key to this phase transformation. Subgrain formation was not necessary for precipitation of Nb ss in αNb₅Si₃, but the partitioning of solutes was essential for this precipitation.
Kohan, Mahmoud; Rezaei-Adaryani, Morteza; Najaf-Yarandi, Akram; Hoseini, Fatemeh; Mohammad-Taheri, Nahid
2014-09-01
To investigate the effects of expiratory ribcage compression (ERCC) before endotracheal suctioning on the arterial blood gases (ABG) in patients receiving mechanical ventilation. Endotracheal suctioning is one of the most frequently used methods for airway clearance in patients receiving mechanical ventilation. Chest physiotherapy techniques such as ERCC before endotracheal suctioning can be used as a means to facilitate mobilizing and removing airway secretions and improving alveolar ventilation. A prospective, randomized, controlled cross-over design. A randomized controlled cross-over trial with a convenience sample of 70 mechanically ventilated patients was conducted from 2006 to 2007. The patients received endotracheal suctioning with (experiment-period) or without (control-period) an antecedent 5-min expiratory ribcage. All the patients experienced both periods with at least a 3-h washed-out interval between the two periods. ABG were measured 5 min before and 25 min after endotracheal suctioning. The statistical tests showed that the levels of partial pressure of oxygen (PaO2 )/fraction of inspired oxygen (FiO2 ), partial pressure of carbon dioxide (PaCO2 ) and arterial oxygen saturation (SaO2 ) in the experimental period at 25 min after the intervention were significantly different from the control period. The tests also revealed that the levels of these variables at 25 min after suctioning were also significantly different from baseline values. However, these differences were clinically significant only for PaO2 /FiO2 . By improving the levels of PaO2 /FiO2 , ERCC can reduce the patients' need for oxygen and hence it can at least reduce the side effects of oxygen therapy. Improving PaO2 /FiO2 levels means less need for oxygen therapy. Hence, by applying ERCC we can at least minimize the side effects of oxygen therapy. © 2014 British Association of Critical Care Nurses.
Gregory, Shaun D; Stevens, Michael C; Pauls, Jo P; Schummy, Emma; Diab, Sara; Thomson, Bruce; Anderson, Ben; Tansley, Geoff; Salamonsen, Robert; Fraser, John F; Timms, Daniel
2016-09-01
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Martinez, F J; Pietchel, S; Wise, C; Walek, J; Beamis, J F
1994-10-01
To examine a hygroscopic condenser after clinical use and to describe the interaction of a hygroscopic condenser and a closed circuit suction system used simultaneously. Prospective evaluation of hygroscopic condensers used clinically, and laboratory investigation of a hygroscopic condenser used with a closed circuit suction system. Tertiary referral centers. The hygroscopic condenser used during mechanical ventilation was removed and peak inflation pressure was measured by delivering a standard tidal volume and inspiratory flow across the isolated hygroscopic condenser while recording the peak inflation pressure. In the laboratory, four 10-mL aliquots of saline were instilled via closed circuit suction system into a test lung with fresh hygroscopic condensers (n = 15) inline. At baseline and after each instillation, the hygroscopic condenser was weighed and the peak inflation pressure was measured while in five condensers, peak expiratory flow rate was also measured. In these five devices, hygroscopic condenser resistance was measured with 100 L/min of constant gas flow while measuring the pressure drop across the hygroscopic condenser. In 11 hygroscopic condensers used for 27.5 +/- 11.9 hrs with no closed circuit suction system, the peak inflation pressure was 3.74 +/- 0.58 cm H2O. In the laboratory, instillation of saline via closed circuit suction system was associated with an increase in hygroscopic condenser weight. Peak inflation pressure increased in a quadratic fashion with the increase in hygroscopic condenser weight, while peak expiratory flow rate decreased in a linear fashion. After four saline instillations, hygroscopic condenser resistance increased from 5.66 +/- 0.31 to 13.9 +/- 2.42 cm H2O/L/sec. Clinical use of a hygroscopic condenser alone is not associated with a significant increase in peak inflation pressure. We caution the use of a hygroscopic condenser and a closed circuit suction system simultaneously, as an increase in hygroscopic condenser resistance may develop and may be poorly tolerated in patients with marginal ventilatory reserve.
Active Control of Flow Separation Over an Airfoil
NASA Technical Reports Server (NTRS)
Ravindran, S. S.
1999-01-01
Designing an aircraft without conventional control surfaces is of interest to aerospace community. In this direction, smart actuator devices such as synthetic jets have been proposed to provide aircraft maneuverability instead of control surfaces. In this article, a numerical study is performed to investigate the effects of unsteady suction and blowing on airfoils. The unsteady suction and blowing is introduced at the leading edge of the airfoil in the form of tangential jet. Numerical solutions are obtained using Reynolds-Averaged viscous compressible Navier-Stokes equations. Unsteady suction and blowing is investigated as a means of separation control to obtain lift on airfoils. The effect of blowing coefficients on lift and drag is investigated. The numerical simulations are compared with experiments from the Tel-Aviv University (TAU). These results indicate that unsteady suction and blowing can be used as a means of separation control to generate lift on airfoils.
[A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].
Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N
1995-04-01
We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.
Finger-triggered portable PDMS suction cup for equipment-free microfluidic pumping
NASA Astrophysics Data System (ADS)
Lee, Sanghyun; Kim, Hojin; Lee, Wonhyung; Kim, Joonwon
2018-12-01
This study presents a finger-triggered portable polydimethylsiloxane suction cup that enables equipment-free microfluidic pumping. The key feature of this method is that its operation only involves a "pressing-and-releasing" action for the cup placed at the outlet of a microfluidic device, which transports the fluid at the inlet toward the outlet through a microchannel. This method is simple, but effective and powerful. The cup is portable and can easily be fabricated from a three-dimensional printed mold, used without any pre-treatment, reversibly bonded to microfluidic devices without leakage, and applied to various material-based microfluidic devices. The effect of the suction cup geometry and fabrication conditions on the pumping performance was investigated. Furthermore, we demonstrated the practical applications of the suction cup by conducting an equipment-free pumping of thermoplastic-based microfluidic devices and water-in-oil droplet generation.
Near-wall serpentine cooled turbine airfoil
Lee, Ching-Pang
2013-09-17
A serpentine coolant flow path (54A-54G) formed by inner walls (50, 52) in a cavity (49) between pressure and suction side walls (22, 24) of a turbine airfoil (20A). A coolant flow (58) enters (56) an end of the airfoil, flows into a span-wise channel (54A), then flows forward (54B) over the inner surface of the pressure side wall, then turns behind the leading edge (26), and flows back along a forward part of the suction side wall, then follows a loop (54E) forward and back around an inner wall (52), then flows along an intermediate part of the suction side wall, then flows into an aft channel (54G) between the pressure and suction side walls, then exits the trailing edge (28). This provides cooling matched to the heating topography of the airfoil, minimizes differential thermal expansion, revives the coolant, and minimizes the flow volume needed.
NASA Technical Reports Server (NTRS)
Swinford, G. R.
1976-01-01
The results of an aircraft wing design study are reported. The selected study airplane configuration is defined. The suction surface, ducting, and compressor systems are described. Techniques of manufacturing suction surfaces are identified and discussed. A wing box of graphite/epoxy composite is defined. Leading and trailing edge structures of composite construction are described. Control surfaces, engine installation, and landing gear are illustrated and discussed. The preliminary wing design is appraised from the standpoint of manufacturing, weight, operations, and durability. It is concluded that a practical laminar flow control (LFC) wing of composite material can be built, and that such a wing will be lighter than an equivalent metal wing. As a result, a program of suction surface evaluation and other studies of configuration, aerodynamics, structural design and manufacturing, and suction systems are recommended.
Spinal cord electrophysiology II: extracellular suction electrode fabrication.
Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William
2011-02-20
Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.
Spinal Cord Electrophysiology II: Extracellular Suction Electrode Fabrication
Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William
2011-01-01
Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively. PMID:21372792
Safety System for Controlling Fluid Flow into a Suction Line
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)
2015-01-01
A safety system includes a sleeve fitted within a pool's suction line at the inlet thereof. An open end of the sleeve is approximately aligned with the suction line's inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining a plurality of distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. Each of the distinct channels is at least approximately three feet in length. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith.
Closed Loop Active Flow Separation Detection and Control in a Multistage Compressor
NASA Technical Reports Server (NTRS)
Bright, Michelle M.; Culley, Dennis E.; Braunscheidel, Edward P.; Welch, Gerard E.
2005-01-01
Active closed loop flow control was successfully demonstrated on a full annulus of stator vanes in a low speed axial compressor. Two independent methods of detecting separated flow conditions on the vane suction surface were developed. The first technique detects changes in static pressure along the vane suction surface, while the second method monitors variation in the potential field of the downstream rotor. Both methods may feasibly be used in future engines employing embedded flow control technology. In response to the detection of separated conditions, injection along the suction surface of each vane was used. Injected mass flow on the suction surface of stator vanes is known to reduce separation and the resulting limitation on static pressure rise due to lowered diffusion in the vane passage. A control algorithm was developed which provided a proportional response of the injected mass flow to the degree of separation, thereby minimizing the performance penalty on the compressor system.
Mullens, Bradley A; Owen, Jeb P; Heft, David E; Sobeck, Ruth V
2005-03-01
Biting insects were sampled to investigate the cause(s) of dermatitis (putative Culicoides hypersensitivity [CHS]) on horses on the Palos Verdes Peninsula, Los Angeles County, California. Suction traps baited with CO2 were operated at 5 sites from April 2002 to August 2003, supplemented by sampling from horses. Six species of Culicoides, 7 species of mosquitoes, and occasional Simulium and Stomoxys were collected in traps. Culicoides sonorensis was the most common midge trapped, although C. obsoletus and C. freeborni also were collected repeatedly. Insects from the belly region of horses in spring (peak dermatitis period) were mostly C. obsoletus, which were far more abundant than indicated by CO2-baited suction traps. The predominant mosquito was Culiseta incidens; Culex quinquefasciatus and Cx. tarsalis also could be common, depending on the site. Mosquitoes, particularly Cs. incidens, were more abundant the 2nd year (normal rainfall), whereas C. sonorensis and C. freeborni were more abundant the 1st year (drought period). Culicoides obsoletus, supplemented by C. sonorensis, is regarded as a primary suspect causing CHS in this area.
Industrializing Offshore Wind Power with Serial Assembly and Lower-cost Deployment - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kempton, Willett
A team of engineers and contractors has developed a method to move offshore wind installation toward lower cost, faster deployment, and lower environmental impact. A combination of methods, some incremental and some breaks from past practice, interact to yield multiple improvements. Three designs were evaluated based on detailed engineering: 1) a 5 MW turbine on a jacket with pin piles (base case), 2) a 10 MW turbine on a conventional jacket with pin piles, assembled at sea, and 3) a 10 MW turbine on tripod jacket with suction buckets (caissons) and with complete turbine assembly on-shore. The larger turbine, assemblymore » ashore, and the use of suction buckets together substantially reduce capital cost of offshore wind projects. Notable capital cost reductions are: changing from 5 MW to 10 MW turbine, a 31% capital cost reduction, and assembly on land then single-piece install at sea an additional 9% capital cost reduction. An estimated Design 4) estimates further cost reduction when equipment and processes of Design 3) are optimized, rather than adapted to existing equipment and process. Cost of energy for each of the four Designs are also calculated, yielding approximately the same percentage reductions. The methods of Design 3) analyzed here include accepted structures such as suction buckets used in new ways, innovations conceived but previously without engineering and economic validation, combined with new methods not previously proposed. Analysis of Designs 2) and 3) are based on extensive engineering calculations and detailed cost estimates. All design methods can be done with existing equipment, including lift equipment, ports and ships (except that design 4 assumes a more optimized ship). The design team consists of experienced offshore structure designers, heavy lift engineers, wind turbine designers, vessel operators, and marine construction contractors. Comparing the methods based on criteria of cost and deployment speed, the study selected the third design. That design is, in brief: a conventional turbine and tubular tower is mounted on a tripod jacket, in turn atop three suction buckets. Blades are mounted on the tower, not on the hub. The entire structure is built in port, from the bottom up, then assembled structures are queued in the port for deployment. During weather windows, the fully-assembled structures are lifted off the quay, lashed to the vessel, and transported to the deployment site. The vessel analyzed is a shear leg crane vessel with dynamic positioning like the existing Gulliver, or it could be a US-built crane barge. On site, the entire structure is lowered to the bottom by the crane vessel, then pumping of the suction buckets is managed by smaller service vessels. Blades are lifted into place by small winches operated by workers in the nacelle without lift vessel support. Advantages of the selected design include: cost and time at sea of the expensive lift vessel are significantly reduced; no jack up vessel is required; the weather window required for each installation is shorter; turbine structure construction is continuous with a queue feeding the weather-dependent installation process; pre-installation geotechnical work is faster and less expensive; there are no sound impacts on marine mammals, thus minimal spotting and no work stoppage Industrializing Offshore Wind Power 6 of 96 9 for mammal passage; the entire structure can be removed for decommissioning or major repairs; the method has been validated for current turbines up to 10 MW, and a calculation using simple scaling shows it usable up to 20 MW turbines.« less
A new suction mask to reduce leak during neonatal resuscitation: a manikin study.
Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G
2016-09-01
Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Jacinto, Cynthia P.; Gastaldi, Ada C.; Aguiar, Daniela Y.; Maida, Karina D.; Souza, Hugo C. D.
2013-01-01
Background The effects of physical therapy on heart rate variability (HRV), especially in children, are still inconclusive. Objective We investigated the effects of conventional physical therapy (CPT) for airway clearance and nasotracheal suction on the HRV of pediatric patients with acute bronchiolitis. Method 24 children were divided into two groups: control group (CG, n=12) without respiratory diseases and acute bronchiolitis group (BG, n=12). The heart rate was recorded in the BG at four different moments: basal recording (30 minutes), 5 minutes after the CPT (10 minutes), 5 minutes after nasotracheal suction (10 minutes), and 40 minutes after nasotracheal suction (30 minutes). The CG was subjected to the same protocol, except for nasotracheal suction. To assess the HRV, we used spectrum analysis, which decomposes the heart rate oscillations into frequency bands: low frequency (LF=0.04-0.15Hz), which corresponds mainly to sympathetic modulation; and high frequency (HF=0.15-1.2Hz), corresponding to vagal modulation. Results Under baseline conditions, the BG showed higher values in LF oscillations, lower values in HF oscillations, and increased LF/HF ratio when compared to the CG. After CPT, the values for HRV in the BG were similar to those observed in the CG during basal recording. Five minutes after nasotracheal suction, the BG showed a decrease in LF and HF oscillations; however, after 40 minutes, the values were similar to those observed after application of CPT. Conclusions The CPT and nasotracheal suction, both used for airway clearance, promote improvement in autonomic modulation of HRV in children with acute bronchiolitis. PMID:24271093
Camp, Ariel L; Brainerd, Elizabeth L
2014-04-15
Suction-feeding fishes capture food by fast and forceful expansion of the mouth cavity, and axial muscles probably provide substantial power for this feeding behavior. Dorsal expansion of the mouth cavity can only be powered by the epaxial muscles, but both the sternohyoid, shortening against an immobile pectoral girdle to retract the hyoid, and the hypaxial muscles, shortening to retract both the pectoral girdle and hyoid, could contribute ventral expansion power. To determine whether hypaxial muscles generate power for ventral expansion, and the rostrocaudal extent of axial muscle shortening during suction feeding, we measured skeletal kinematics and muscle shortening in largemouth bass (Micropterus salmoides). The three-dimensional motions of the cleithrum and hyoid were measured with X-ray reconstruction of moving morphology (XROMM), and muscle shortening was measured with fluoromicrometry, wherein changes in the distance between radio-opaque intramuscular markers are measured using biplanar X-ray video recording. We found that the hypaxials generated power for ventral suction expansion, shortening (mean of 6.2 mm) to rotate the pectoral girdle caudoventrally (mean of 9.3 deg) and retract the hyoid (mean of 8.5 mm). In contrast, the sternohyoid shortened minimally (mean of 0.48 mm), functioning like a ligament to transmit hypaxial shortening to the hyoid. Hypaxial and epaxial shortening were not confined to the rostral muscle regions, but extended more than halfway down the body during suction expansion. We conclude that hypaxial and epaxial muscles are both crucial for powering mouth expansion in largemouth bass, supporting the integration of axial and cranial musculoskeletal systems for suction feeding.
NASA Astrophysics Data System (ADS)
Limbach, P.; Müller, T.; Skoda, R.
2015-12-01
Commonly, for the simulation of cavitation in centrifugal pumps incompressible flow solvers with VOF kind cavitation models are applied. Since the source/sink terms of the void fraction transport equation are based on simplified bubble dynamics, empirical parameters may need to be adjusted to the particular pump operating point. In the present study a barotropic cavitation model, which is based solely on thermodynamic fluid properties and does not include any empirical parameters, is applied on a single flow channel of a pump impeller in combination with a time-explicit viscous compressible flow solver. The suction head curves (head drop) are compared to the results of an incompressible implicit standard industrial CFD tool and are predicted qualitatively correct by the barotropic model.
NASA Technical Reports Server (NTRS)
Hall, P.; Malik, M. R.
1986-01-01
The instability of a three-dimensional attachment-line boundary layer is considered in the nonlinear regime. Using weakly nonlinear theory, it is found that, apart from a small interval near the (linear) critical Reynolds number, finite-amplitude solutions bifurcate subcritically from the upper branch of the neutral curve. The time-dependent Navier-Stokes equations for the attachment-line flow have been solved using a Fourier-Chebyshev spectral method and the subcritical instability is found at wavenumbers that correspond to the upper branch. Both the theory and the numerical calculations show the existence of supercritical finite-amplitude (equilibrium) states near the lower branch which explains why the observed flow exhibits a preference for the lower branch modes. The effect of blowing and suction on nonlinear stability of the attachment-line boundary layer is also investigated.
NASA Technical Reports Server (NTRS)
Hall, P.; Malik, M. R.
1984-01-01
The instability of a three dimensional attachment line boundary layer is considered in the nonlinear regime. Using weakly nonlinear theory, it is found that, apart from a small interval near the (linear) critical Reynolds number, finite amplitude solutions bifurcate subcritically from the upper branch of the neutral curve. The time dependent Navier-Stokes equations for the attachment line flow have been solved using a Fourier-Chebyshev spectral method and the subcritical instability is found at wavenumbers that correspond to the upper branch. Both the theory and the numerical calculations show the existence of supercritical finite amplitude (equilibrium) states near the lower branch which explains why the observed flow exhibits a preference for the lower branch modes. The effect of blowing and suction on nonlinear stability of the attachment line boundary layer is also investigated.
NASA Astrophysics Data System (ADS)
Saeed Butt, Adnan; Ali, Asif
2014-01-01
The present article aims to investigate the entropy effects in magnetohydrodynamic flow and heat transfer over an unsteady permeable stretching surface. The time-dependent partial differential equations are converted into non-linear ordinary differential equations by suitable similarity transformations. The solutions of these equations are computed analytically by the Homotopy Analysis Method (HAM) then solved numerically by the MATLAB built-in routine. Comparison of the obtained results is made with the existing literature under limiting cases to validate our study. The effects of unsteadiness parameter, magnetic field parameter, suction/injection parameter, Prandtl number, group parameter and Reynolds number on flow and heat transfer characteristics are checked and analysed with the aid of graphs and tables. Moreover, the effects of these parameters on entropy generation number and Bejan number are also shown graphically. It is examined that the unsteadiness and presence of magnetic field augments the entropy production.
Monitoring And Controlling Hydroponic Flow
NASA Technical Reports Server (NTRS)
Dreschel, Thomas W.
1992-01-01
Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.
NASA Astrophysics Data System (ADS)
Figueroa, A.; Tindall, J. A.; Friedel, M. J.
2005-12-01
Concentration of delO18 in water samples extracted by suction lysimeters is compared to samples obtained by methods of centrifugation and azeotropic distillation. Intact soil cores (30 cm diameter by 40 cm height) were extracted from two different sites. Site 1 was rapid infiltration basin number 50, near Altamonte Springs in Seminole County, Florida on properties belonging to the Walt Disney World Resort Complex. Site 2 was the Missouri Management System Evaluation Area (MSEA) near Centralia in Boone County, Missouri. The delO18 water was analyzed on a mass spectrophotometer. Potassium Bromide (KBr) was also used as a tracer and analyzed by ion chromatography. A portion of the data obtained was modeled using CXTFIT. Water collected by centrifugation and azeotropic distillation data were about 2-5% more negative than that collected by suction lysimeter values from the Florida (sandy) soil and about 5-7 % more negative from the Missouri (well structured clay) soil. Results indicate that the majority of soil water in well structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. Also, it is plausible that evaporation caused some delO18 enrichment in the suction lysimeters. Suction lysimeters preferentially sampled water held at lower matric potentials, which may not represent total soil water. In cases where a sufficient volume of water has passed through the soil profile and displaced all previous pore water, suction lysimeters will however collect a representative sample of all the water at that depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeters be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The CXTFIT program worked well for Florida soils (a more homogeneous sand), but gave poor performance for Missouri soils (well structured clays) except for deeper depths where clay structure was less variable. The data also suggest that each extraction method samples a separate component of soil-pore water. Consequently, centrifugation can be used with good success, particularly for efficient sampling of large areas. Azeotropic distillation is more appropriate when strict qualitative and quantitative data for desorption, desorption, and various types of kinetic studies are needed.
Design and analysis of axial aspirated compressor stages
NASA Astrophysics Data System (ADS)
Merchant, Ali A.
The pressure ratio of axial compressor stages can be significantly increased by controlling the development of blade and endwall boundary layers in regions of adverse pressure gradient by means of boundary layer suction. This concept is validated and demonstrated through the design and analysis of two unique aspirated compressor stages: a low-speed stage with a design pressure ratio of 1.6 at a tip speed of 750 ft/s, and a high-speed stage with a design pressure ratio of 3.5 at a tip speed of 1500 ft/s. The aspirated compressor stages were designed using a new procedure which is a synthesis of low speed and high speed blade design techniques combined with a flexible inverse design method which enabled precise independent control over the shape of the blade suction and pressure surfaces. Integration of the boundary layer suction calculation into the overall design process is an essential ingredient of the new procedure. The blade design system consists of two axisymmetric through-flow codes coupled with a quasi three-dimensional viscous cascade plane code with inverse design capability. Validation of the completed designs were carried out with three-dimensional Euler and Navier-Stokes calculations. A single spanwise slot on the blade suction surface is used to bleed the boundary layer. The suction mass flow requirement for the low-speed and high-speed stages are 1% and 4% of the inlet mass flow, respectively. Additional suction between 1-2% is also required on the compressor endwalls near shock impingement locations. The rotor is modeled with a tip shroud to eliminate tip clearance effects and to discharge the suction flow radially from the flowpath. Three-dimensional viscous evaluation of the designs showed good agreement with the quasi three-dimensional design intent, except in the endwall regions. The suction requirements predicted by the quasi three-dimensional calculation were confirmed by the three-dimensional viscous calculations. The three-dimensional viscous analysis predicted a peak pressure ratio of 1.59 at an isentropic efficiency of 89% for the low-speed stage, and a peak pressure ratio of 3.68 at an isentropic efficiency of 94% for the high-speed rotor. (Copies available exclusively from MIT Libraries, Rm. 14-0551, Cambridge, MA 02139-4307. Ph. 617-253-5668; Fax 617-253-1690.)
Tube Suction Test for Evaluating
DOT National Transportation Integrated Search
2012-06-01
In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...
33 CFR 162.80 - Mississippi River below mouth of Ohio River, including South and Southwest passes.
Code of Federal Regulations, 2012 CFR
2012-07-01
... withstand currents, winds, wave action, suction from passing vessels or any other forces which might cause... sufficient fastenings to prevent the vessels from breaking loose by wind, current, wave action, suction from...
33 CFR 162.80 - Mississippi River below mouth of Ohio River, including South and Southwest passes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... withstand currents, winds, wave action, suction from passing vessels or any other forces which might cause... sufficient fastenings to prevent the vessels from breaking loose by wind, current, wave action, suction from...
33 CFR 162.80 - Mississippi River below mouth of Ohio River, including South and Southwest passes.
Code of Federal Regulations, 2013 CFR
2013-07-01
... withstand currents, winds, wave action, suction from passing vessels or any other forces which might cause... sufficient fastenings to prevent the vessels from breaking loose by wind, current, wave action, suction from...
33 CFR 162.80 - Mississippi River below mouth of Ohio River, including South and Southwest passes.
Code of Federal Regulations, 2014 CFR
2014-07-01
... withstand currents, winds, wave action, suction from passing vessels or any other forces which might cause... sufficient fastenings to prevent the vessels from breaking loose by wind, current, wave action, suction from...
33 CFR 162.80 - Mississippi River below mouth of Ohio River, including South and Southwest passes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... withstand currents, winds, wave action, suction from passing vessels or any other forces which might cause... sufficient fastenings to prevent the vessels from breaking loose by wind, current, wave action, suction from...
Great Bend tornadoes of August 30, 1974
NASA Technical Reports Server (NTRS)
Umenhofer, T. A.; Fujita, T. T.; Dundas, R.
1977-01-01
Photogrammetric analyses of movies and still pictures taken of the Great Bend, Kansas Tornado series have been used to develop design specifications for nuclear power plants and facilities. A maximum tangential velocity of 57 m/sec and a maximum vertical velocity of 27 m/sec are determined for one suction vortex having a translational velocity of 32 m/sec. Three suction vortices with radii in the 20 to 30 m range are noted in the flow field of one tornado; these suction vortices apparently form a local convergence of inflow air inside the outer portion of the tornado core.
Application of laminar flow control to supersonic transport configurations
NASA Technical Reports Server (NTRS)
Parikh, P. G.; Nagel, A. L.
1990-01-01
The feasibility and impact of implementing a laminar flow control system on a supersonic transport configuration were investigated. A hybrid laminar flow control scheme consisting of suction controlled and natural laminar flow was developed for a double-delta type wing planform. The required suction flow rates were determined from boundary layer stability analyses using representative wing pressure distributions. A preliminary design of structural modifications needed to accommodate suction through a perforated titanium skin was carried out together with the ducting and systems needed to collect, compress and discharge the suction air. The benefits of reduced aerodynamic drag were weighed against the weight, volume and power requirement penalties of suction system installation in a mission performance and sizing program to assess the net benefits. The study showed a feasibility of achieving significant laminarization of the wing surface by use of a hybrid scheme, leading to an 8.2 percent reduction in the cruise drag. This resulted in an 8.5 percent reduction in the maximum takeoff weight and a 12 percent reduction in the fuel burn after the inclusion of the LFC system installation penalties. Several research needs were identified for a resolution of aerodynamics, structural and systems issues before these potential benefits could be realized in a practical system.
NASA Astrophysics Data System (ADS)
Wang, Z. L.; Shen, Y. F.; Wang, Z. B.; Wang, J.
2017-08-01
Semi-closed single screw refrigeration compressors (SSRC) are widely used in refrigeration and air conditioning systems owing to the advantages of simple structure, balanced forces on the rotor, high volumetric efficiency and so on. In semi-closed SSRCs, motor is often cooled by suction gas or injected refrigerant liquid. Motor cooling method will changes the suction gas temperature, this to a certain extent, is an important factor influencing the thermal dynamic performance of a compressor. Thus the effects of motor cooling method on the performance of the compressor must be studied. In this paper mathematical models of motor cooling process by using these two methods were established. Influences of motor cooling parameters such as suction gas temperature, suction gas quantity, temperature of the injected refrigerant liquid and quantity of the injected refrigerant liquid on the thermal dynamic performance of the compressor were analyzed. The performances of the compressor using these two kinds of motor cooling methods were compared. The motor cooling capacity of the injected refrigerant liquid is proved to be better than the suction gas. All analysis results obtained can be useful for optimum design of the motor cooling process to improve the efficiency and the energy efficiency of the compressor.
Suys, E; Nieboer, K; Stiers, W; De Regt, J; Huyghens, L; Spapen, H
2013-12-01
Injurious prolapse of tracheal mucosa into the suction port has been reported in up to 50% of intubated patients receiving continuous aspiration of subglottic secretions. We investigated whether similar injury could be inflicted by automated intermittent aspiration. Six consecutive patients, intubated with the Mallinckrodt TaperGuard Evac™ endotracheal tube, were studied. A flow sensor was placed between the vacuum regulating system and the mucus collector. Intermittent suctioning was performed at a pressure of -125 mmHg with a 25s interval and duration of 15s. After 24h, a CT scan of the tracheal region was performed. Excessive negative suction pressure, a fast drop in aspiration flow to zero, and important "swinging" movements of secretions in the evacuation line were observed in all patients. Oral instillation of antiseptic mouthwash restored normal aspiration flow and secretion mobility. CT imaging showed marked entrapment of tracheal mucosa into the suction port in all patients. In patients with few oropharyngeal secretions, automated intermittent subglottic aspiration may result in significant and potential harmful invagination of tracheal mucosa into the suction lumen. A critical amount of fluid must be present in the oropharynx to assure adequate and safe aspiration. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Benhachmi, Driss; Greber, Isaac; Hingst, Warren R.
1988-01-01
A combined experimental and numerical study of the interaction of an incident oblique shock wave with a turbulent boundary layer on a rough plate and on a porous plate with suction is presented. The experimental phase involved the acquisition of mean data upstream of, within, and downstream of the interaction region at Mach numbers 2.5 and 3.0. Data were taken at unit Reynolds numbers of 1.66 E7 and 1.85 E7 m respectively, and for flow deflection angles of 0, 4, 6 and 8 degs. Measured data include wall static pressure, pitot pressure profiles, and local bleed distributions on the porous plate. On the rough plate, with no suction, the boundary layer profiles were modified near the wall, but not separated for the 4 deg flow deflection angle. For the higher deflection angles of 6 and 8 degs, the boundary layer was separated. Suction increases the strength of the incident shock required to separate the turbulent boundary layer; for all shock strengths tested, separation is completely eliminated. The pitot pressure profiles are affected throughout the whole boundary layer; they are fuller than the ones obtained on the rough plate. It is also found that the combination of suction and roughness introduces spatial perturbations.
Placement of percutaneous transhepatic biliary stent using a silicone drain with channels
Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi
2009-01-01
This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159
NASA Astrophysics Data System (ADS)
Hughes, P. N.
2015-12-01
A soil's shear resistance is mainly dependent upon the magnitude of effective stress. For small to medium height slopes (up to 10m) in clay soils the total stress acting along potential failure planes will be low, therefore the magnitude of effective stress (and hence soil shear strength) will be dominated by the pore-water pressure. The stability of slopes on this scale through periods of increased precipitation is improved by the generation of negative pore pressures (soil suctions) during preceding, warmer, drier periods. These negative pore water pressures increase the effective stress within the soil and cause a corresponding increase in shearing resistance. The relationships between soil water content and pore water pressure (soil water retention curves) are known to be hysteretic, but for the purposes of the majority of slope stability assessments in partially saturated clay soils, these are assumed to be consistent with time. Similarly, the relationship between shear strength and water content is assumed to be consistent over time. This research presents a laboratory study in which specimens of compacted Glacial Till (typical of engineered slopes within the UK) were subjected to repeated cycles of wetting and drying to simulate seasonal cycles. At predetermined water contents, measurements of soil suction were made using tensiometer and dewpoint potentiometer methods. The undrained shear strength of the specimens was then measured using triaxial strength testing equipment. Results indicate that repeated wetting and drying cycles caused a change in the soil water retention behaviour. A reduction in undrained shear strength at corresponding water contents along the wetting and drying paths was also observed. The mechanism for the change in the relationship is believed to be a deterioration in the soil physical structure due to shrink/swell induced micro-cracking. The non-stationarity of these relationships has implications for slope stability assessment.
Effect of suction hysteresis on resilient modulus of fine-grained cohesionless soil.
DOT National Transportation Integrated Search
2010-07-30
The mechanical behavior of subgrade soil is influenced by the seasonal variations in moisture content. To better understand this behavior, it is crucial to study the relationship between soil moisture content and matric suction known as the Soil Wate...
Gregory, Shaun D; Schummy, Emma; Pearcy, Mark; Pauls, Jo P; Tansley, Geoff; Fraser, John F; Timms, Daniel
2015-02-01
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
The paradox of negative pressure wound therapy--in vitro studies.
Kairinos, Nicolas; Solomons, Michael; Hudson, Donald A
2010-01-01
Negative-pressure wound therapy (NPWT) has revolutionised wound care. Yet, it is still not understood how hypobaric tissue pressure accelerates wound healing. There is very little reported on the relevant physics of any substance subjected to suction in this manner. The common assumption is that applying suction to a substance is likely to result in a reduction of pressure in that substance. Although more than 250 research articles have been published on NPWT, there are little data verifying whether suction increases or decreases the pressure of the substance it is applied to. Clarifying this basic question of physics is the first step in understanding the mechanism of action of these dressings. In this study, pressure changes were recorded in soft plasticene and processed meat, using an intracranial tissue pressure microsensor. Circumferential, non-circumferential and cavity NPWT dressings were applied, and pressure changes within the underlying substance were recorded at different suction pressures. Pressures were also measured at 1cm, 2 cm and 3 cm from the NPWT placed in a cavity. In all three types of NPWT dressings, the underlying substance pressure was increased (hyperbaric) as suction pressure increased. Although there was a substantial pressure increase at 1cm, the rise in pressure at the 2-cm and 3-cm intervals was minimal. Substance pressure beneath all types of NPWT dressing is hyperbaric in inanimate substances. Higher suction pressures generate greater substance pressures; however, the increased pressure rapidly dissipates as the distance from the dressing is increased. The findings of this study on inanimate objects suggest that we may need to review our current perception of the physics underlying NPWT dressings. Further research of this type on living tissues is warranted. Copyright (c) 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Kim, Young-Hoon; Kim, Chae-Yong; Oh, Chang Wan
2013-01-01
Objective We performed this study to investigate whether the use of closed-suction drainage following microvascular decompression (MVD) causes cerebrospinal fluid (CSF) leakage. Methods Between 2004 and 2011, a total of 157 patients with neurovascular compression were treated with MVD. MVD was performed for hemifacial spasm in 150 (95.5%) cases and for trigeminal neuralgia in 7 (4.5%) cases. The mean age of the patients was 49.8±9.6 years (range, 20-69). Dural substitutes were used in 44 (28.0%) patients. Ninety-two patients (58.6%) were underwent a 4-5 cm craniotomy using drainage (drainage group), and 65 (41.4%) did a small 2-2.5 cm retromastoid craniectomy without closed-suction drainage (no-drainage group). Results Eleven (7.0%) patients experienced CSF leakage following MVD based on the criteria of this study; all of these patients were in the drainage group. In the unadjusted analyses, the incidence of CSF leakage was significantly related with the use of closed-suction drainage following MVD (12.0% in the drainage group vs. 0% in the no-drainage group, respectively; p=0.003; Fisher's exact test). Those who received dural substitutes and the elderly (cut-off value=60 years) exhibited a tendency to develop CSF leakage (p=0.075 and p=0.090, respectively; Fisher's exact test). In the multivariate analysis, only the use of closed-suction drainage was significantly and independently associated with the development of CSF leakage following MVD (odds ratio=9.900; 95% confidence interval, 1.418 to infinity; p=0.017). Conclusion The use of closed-suction drainage following MVD appears to be related to the development of CSF leakage. PMID:24175025
Gilder, Eileen; Parke, Rachael L; Jull, Andrew
2018-04-14
Despite the evidence and available guidelines about endotracheal suction (ETS), a discrepancy between published guidelines and clinical practice persists. To date, ETS practice in the adult intensive care unit (ICU) population across New Zealand and Australia has not been described. To describe ICU nurses' ETS practice in New Zealand and Australia including the triggers for performing endotracheal suction. A single day, prospective observational, binational, multicentre point prevalence study in New Zealand and Australian ICUs. All adult patients admitted at 10:00 on the study day were included. In addition to patient demographic data, we assessed triggers for ETS, suction canister pressures, use of preoxygenation, measures of oxygenation, and ETS at extubation. There were 682 patients in the ICUs on the study day, and 230 were included in the study. Three of 230 patients were excluded for missing data. A total of 1891 ETS events were performed on 227 patients during the study day, a mean of eight interventions per patient. The main triggers reported were audible (n = 385, 63%) and visible (n = 239, 39%) secretions. Less frequent triggers included following auscultation (n = 142, 23%), reduced oxygen saturations (n = 140, 22%), and ventilator waveforms (n = 53, 9%). Mean suction canister pressure was -337 mmHg (standard deviation = 189), 67% of patients received preoxygenation (n = 413), and ETS at extubation was performed by 84% of nurses. Some practices were inconsistent with international guidelines, in particular concerning patient assessment for ETS and suction canister pressure. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
Ramsay, Jason B; Wilga, Cheryl D
2017-11-01
Suction feeding in teleost fish is a power-dependent behavior, requiring rapid and forceful expansion of the orobranchial cavity by the hypobranchial and trunk muscles. To increase power production for expansion, many species employ in-series tendons and catch mechanisms to store and release elastic strain energy. Suction feeding sharks such as Chiloscyllium plagiosum lack large in-series tendons on the hypobranchials, yet two of the hypobranchials, the coracohyoideus and coracoarcualis (CH and CA; hyoid depressors), are arranged in-series, and run deep and parallel to a third muscle, the coracomandibularis (CM, jaw depressor). The arrangement of the CH and CA suggests that C. plagiosum is using the CH muscle rather than a tendon to store and release elastic strain energy. Here we describe the anatomy of the feeding apparatus, and present data on hyoid and jaw kinematics and fascicle shortening in the CM, CH and CA quantified using sonomicrometry, with muscle activity and buccal pressure recorded simultaneously. Results from prey capture show that prior to jaw and hyoid depression the CH is actively lengthened by shortening of the in-series CA. The active lengthening of the CH and pre-activation of the CH and CA suggest that the CH is functioning to store and release elastic energy during prey capture. Catch mechanisms are proposed involving a dynamic moment arm and four-bar linkage between the hyoidiomandibular ligament (LHML), jaws and ceratohyals that is influenced by the CM. Furthermore, the LHML may be temporarily disengaged during behaviors such as bite processing to release linkage constraints. © 2017. Published by The Company of Biologists Ltd.
Tube suction test for evaluating durability of cementitiously stabilized soils.
DOT National Transportation Integrated Search
2011-06-01
In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... The device consists of a powered suction pump (containing a microbial filter on the exhaust and a microbial in-line filter in the connecting tubing between the collection bottle and the safety trap), collection bottle, cannula, and connecting tube. The microbial filters, tubing, collection bottle, and...
21 CFR 878.5040 - Suction lipoplasty system.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... The device consists of a powered suction pump (containing a microbial filter on the exhaust and a microbial in-line filter in the connecting tubing between the collection bottle and the safety trap), collection bottle, cannula, and connecting tube. The microbial filters, tubing, collection bottle, and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... avoid damage by suction or wave wash to wharves, landings, riprap protection, or other boats, or injury... suction or wave wash does occur. Owners and operators of yachts, motorboats, rowboats and other craft are...
Code of Federal Regulations, 2014 CFR
2014-07-01
... avoid damage by suction or wave wash to wharves, landings, riprap protection, or other boats, or injury... suction or wave wash does occur. Owners and operators of yachts, motorboats, rowboats and other craft are...
Code of Federal Regulations, 2013 CFR
2013-07-01
... avoid damage by suction or wave wash to wharves, landings, riprap protection, or other boats, or injury... suction or wave wash does occur. Owners and operators of yachts, motorboats, rowboats and other craft are...
Code of Federal Regulations, 2012 CFR
2012-07-01
... avoid damage by suction or wave wash to wharves, landings, riprap protection, or other boats, or injury... suction or wave wash does occur. Owners and operators of yachts, motorboats, rowboats and other craft are...
Tube suction test for evaluating durability of cementitiously stabilized soils.
DOT National Transportation Integrated Search
2011-06-01
In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (FT/ : W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moistur...
FCA Group LLC request to the EPA regarding greenhouse (GHG) off-cycle credit for the use of the Denso SAS AC compressor with variable crankcase suction valve technology beginning with the 2019 MY Ram pickup truck.
Evaluation of viscous drag reduction schemes for subsonic transports
NASA Technical Reports Server (NTRS)
Marino, A.; Economos, C.; Howard, F. G.
1975-01-01
The results are described of a theoretical study of viscous drag reduction schemes for potential application to the fuselage of a long-haul subsonic transport aircraft. The schemes which were examined included tangential slot injection on the fuselage and various synergetic combinations of tangential slot injection and distributed suction applied to wing and fuselage surfaces. Both passive and mechanical (utilizing turbo-machinery) systems were examined. Overall performance of the selected systems was determined at a fixed subsonic cruise condition corresponding to a flight Mach number of free stream M = 0.8 and an altitude of 11,000 m. The nominal aircraft to which most of the performance data was referenced was a wide-body transport of the Boeing 747 category. Some of the performance results obtained with wing suction are referenced to a Lockheed C-141 Star Lifter wing section. Alternate designs investigated involved combinations of boundary layer suction on the wing surfaces and injection on the fuselage, and suction and injection combinations applied to the fuselage only.
NASA Technical Reports Server (NTRS)
Oeztuerk, B; Schobeiri, M. T.; Ashpis, David E.
2005-01-01
The paper experimentally and theoretically studies the effects of periodic unsteady wake flow and aerodynamic characteristics on boundary layer development, separation and re-attachment along the suction surface of a low pressure turbine blade. The experiments were carried out at Reynolds number of 110,000 (based on suction surface length and exit velocity). For one steady and two different unsteady inlet flow conditions with the corresponding passing frequencies, intermittency behaviors were experimentally and theoretically investigated. The current investigation attempts to extend the intermittency unsteady boundary layer transition model developed in previously to the LPT cases, where separation occurs on the suction surface at a low Reynolds number. The results of the unsteady boundary layer measurements and the intermittency analysis were presented in the ensemble-averaged and contour plot forms. The analysis of the boundary layer experimental data with the flow separation, confirms the universal character of the relative intermittency function which is described by a Gausssian function.
NASA Astrophysics Data System (ADS)
Raju, C. S. K.; Ibrahim, S. M.; Anuradha, S.; Priyadharshini, P.
2016-11-01
In modern days, the mass transfer rate is challenging to the scientists due to its noticeable significance for industrial as well as engineering applications; owing to this we attempt to study the cross-diffusion effects on the magnetohydrodynamic nonlinear radiative Carreau fluid over a wedge filled with gyro tactic microorganisms. Numerical results are presented graphically as well as in tabular form with the aid of the Runge-Kutta and Newton methods. The effects of pertinent parameters on velocity, temperature, concentration and density of motile organism distributions are presented and discussed for two cases (suction and injection flows). For real-life application we also calculated the local Nusselt and Sherwood numbers. It is observed that thermal and concentration profiles are not uniform in the suction and injection flow cases. It is found that the heat and mass transport phenomenon is high in the injection case, while heat and mass transfer rates are high in the suction flow case.
Four-wall turbine airfoil with thermal strain control for reduced cycle fatigue
Cambell, Christian X
2013-09-17
A turbine airfoil (20B) with a thermal expansion control mechanism that increases the airfoil camber (60, 61) under operational heating. The airfoil has four-wall geometry, including pressure side outer and inner walls (26, 28B), and suction side outer and inner walls (32, 34B). It has near-wall cooling channels (31F, 31A, 33F, 33A) between the outer and inner walls. A cooling fluid flow pattern (50C, 50W, 50H) in the airfoil causes the pressure side inner wall (28B) to increase in curvature under operational heating. The pressure side inner wall (28B) is thicker than walls (26, 34B) that oppose it in camber deformation, so it dominates them in collaboration with the suction side outer wall (32), and the airfoil camber increases. This reduces and relocates a maximum stress area (47) from the suction side outer wall (32) to the suction side inner wall (34B, 72) and the pressure side outer wall (26).
Nicergoline inhibits T-type Ca2+ channels in rat isolated hippocampal CA1 pyramidal neurones.
Takahashi, K.; Akaike, N.
1990-01-01
1. The effects of nicergoline on the T- and L-type Ca2+ currents in pyramidal cells freshly isolated from rat hippocampal CA1 region were investigated by use of a 'concentration-clamp' technique. The technique combines a suction-pipette technique, which allows intracellular perfusion under a single-electrode voltage-clamp, and rapid exchange of extracellular solution within 2 ms. 2. T-type Ca2+ currents were evoked by step depolarizations from a holding potential of -100 mV to potentials more positive than -70 to -60 mV, and reached a peak at about -30 mV in the current-voltage relationship. Activation and inactivation of T-type Ca2+ currents were highly potential-dependent. 3. Nicergoline and other Ca2+ antagonists dose-dependently blocked the T-type Ca2+ channel with an order of potency nicardipine greater than nicergoline greater than diltiazem. 4. The L-type Ca2+ channel was also blocked in the order nicardipine greater than nicergoline greater than diltiazem, although the T-type Ca2+ channel was more sensitive to nicergoline. 5. The inhibitory effects of nicergoline and nicardipine on the T-type Ca2+ current were voltage-, time-, and use-dependent, and the inhibition increased with a decrease in the external Ca2+ concentration. Diltiazem showed only a use-dependent block. PMID:2169937
Nicergoline inhibits T-type Ca2+ channels in rat isolated hippocampal CA1 pyramidal neurones.
Takahashi, K; Akaike, N
1990-08-01
1. The effects of nicergoline on the T- and L-type Ca2+ currents in pyramidal cells freshly isolated from rat hippocampal CA1 region were investigated by use of a 'concentration-clamp' technique. The technique combines a suction-pipette technique, which allows intracellular perfusion under a single-electrode voltage-clamp, and rapid exchange of extracellular solution within 2 ms. 2. T-type Ca2+ currents were evoked by step depolarizations from a holding potential of -100 mV to potentials more positive than -70 to -60 mV, and reached a peak at about -30 mV in the current-voltage relationship. Activation and inactivation of T-type Ca2+ currents were highly potential-dependent. 3. Nicergoline and other Ca2+ antagonists dose-dependently blocked the T-type Ca2+ channel with an order of potency nicardipine greater than nicergoline greater than diltiazem. 4. The L-type Ca2+ channel was also blocked in the order nicardipine greater than nicergoline greater than diltiazem, although the T-type Ca2+ channel was more sensitive to nicergoline. 5. The inhibitory effects of nicergoline and nicardipine on the T-type Ca2+ current were voltage-, time-, and use-dependent, and the inhibition increased with a decrease in the external Ca2+ concentration. Diltiazem showed only a use-dependent block.
Characteristics of Boundary Layer Transition in a Multi-Stage Low-Pressure Turbine
NASA Technical Reports Server (NTRS)
Wisler, Dave; Halstead, David E.; Okiishi, Ted
2007-01-01
An experimental investigation of boundary layer transition in a multi-stage turbine has been completed using surface-mounted hot-film sensors. Tests were carried out using the two-stage Low Speed Research Turbine of the Aerodynamics Research Laboratory of GE Aircraft Engines. Blading in this facility models current, state-of-the-art low pressure turbine configurations. The instrumentation technique involved arrays of densely-packed hot-film sensors on the surfaces of second stage rotor and nozzle blades. The arrays were located at mid-span on both the suction and pressure surfaces. Boundary layer measurements were acquired over a complete range of relevant Reynolds numbers. Data acquisition capabilities provided means for detailed data interrogation in both time and frequency domains. Data indicate that significant regions of laminar and transitional boundary layer flow exist on the rotor and nozzle suction surfaces. Evidence of relaminarization both near the leading edge of the suction surface and along much of the pressure surface was observed. Measurements also reveal the nature of the turbulent bursts occuring within and between the wake segments convecting through the blade row. The complex character of boundary layer transition resulting from flow unsteadiness due to nozzle/nozzle, rotor/nozzle, and nozzle/rotor wake interactions are elucidated using these data. These measurements underscore the need to provide turbomachinery designers with models of boundary layer transition to facilitate accurate prediction of aerodynamic loss and heat transfer.
The influence of a suction device on fixation of a cemented cup using RSA.
Timperley, A John; Whitehouse, Sarah L; Hourigan, Patrick G
2009-03-01
The quality of technique used at the time of socket cementation is crucial in ensuring a durable long-term result of the implant. We asked whether a new instrument, an aspirator retractor introduced into the wing of the ilium before socket preparation and cementation, would enhance cement fixation as defined by RSA and radiographic examination. We randomized 38 patients into two groups. The surgical technique was identical between the groups with the exception of the use of the aspirator retractor. Patients were followed clinically and with radiostereometry at a minimum of 2 years. We compared gross radiographic appearances, including the depth of penetration of cement and the incidence of postoperative and 2-year radiolucent lines. There was no difference in proximal migration between the two groups. No improvement of fixation was proven from the measured translations and rotations of the socket in the suction group. We found no difference in the number or extent of radiolucent lines or the depth of cement penetration when the iliac suction device was used in conjunction with contemporary cementing techniques. Although the data suggest no short-term advantage in this small study, we will continue to follow these patients presuming there will be improved outcomes in the longer term and since the device provides an easier method of obtaining adequate fixation, especially if technical difficulties are encountered during the pressurization procedure.
Time resolved measurements of the flow generated by suction feeding fish
NASA Astrophysics Data System (ADS)
Day, Steven W.; Higham, Timothy E.; Wainwright, Peter C.
2007-11-01
The majority of aquatic vertebrates are suction feeders: by rapidly expanding the mouth cavity they generate a fluid flow outside of their head in order to draw prey into their mouth. In addition to the biological relevance, the generated flow field is interesting fluid mechanically as it incorporates high velocities, is localized in front of the mouth, and is unsteady, typically lasting between 10 and 50 ms. Using manometry and high-speed particle image velocimetry, this is the first study to quantify pressure within and outside the mouth of a feeding fish while simultaneously measuring the velocity field outside the mouth. Measurements with a high temporal (2 ms) and spatial (<1 mm) resolution were made for several feeding events of a single largemouth bass ( Micropterus salmoides). General properties of the flow were evaluated, including the transient velocity field, its relationship to pressure within the mouth and pressure at the prey. We find that throughout the feeding event a relationship exists for the magnitude of fluid speed as a function of distance from the predator mouth that is based on scaling the velocity field according to the size of the mouth opening and the magnitude of fluid speed at the mouth. The velocity field is concentrated within an area extending approximately one mouth diameter from the fish and the generated pressure field is even more local to the mouth aperture. Although peak suction pressures measured inside the mouth were slightly larger than those that were predicted using the equations of motion, we find that these equations give a very accurate prediction of the timing of peak pressure, so long as the unsteady nature of the flow is included.
Time resolved measurements of the flow generated by suction feeding fish
NASA Astrophysics Data System (ADS)
Day, Steven W.; Higham, Timothy E.; Wainwright, Peter C.
The majority of aquatic vertebrates are suction feeders: by rapidly expanding the mouth cavity they generate a fluid flow outside of their head in order to draw prey into their mouth. In addition to the biological relevance, the generated flow field is interesting fluid mechanically as it incorporates high velocities, is localized in front of the mouth, and is unsteady, typically lasting between 10 and 50 ms. Using manometry and high-speed particle image velocimetry, this is the first study to quantify pressure within and outside the mouth of a feeding fish while simultaneously measuring the velocity field outside the mouth. Measurements with a high temporal (2 ms) and spatial (<1 mm) resolution were made for several feeding events of a single largemouth bass (Micropterus salmoides). General properties of the flow were evaluated, including the transient velocity field, its relationship to pressure within the mouth and pressure at the prey. We find that throughout the feeding event a relationship exists for the magnitude of fluid speed as a function of distance from the predator mouth that is based on scaling the velocity field according to the size of the mouth opening and the magnitude of fluid speed at the mouth. The velocity field is concentrated within an area extending approximately one mouth diameter from the fish and the generated pressure field is even more local to the mouth aperture. Although peak suction pressures measured inside the mouth were slightly larger than those that were predicted using the equations of motion, we find that these equations give a very accurate prediction of the timing of peak pressure, so long as the unsteady nature of the flow is included.
Toward an easier indigocarmine chromoendoscopy.
Barret, Maximilien; Camus, Marine; Leblanc, Sarah; Coriat, Romain; Prat, Frédéric; Chaussade, Stanislas
2015-07-10
Indigocarmine chromoendoscopy has been proven to improve the detection of colonic lesions during screening colonoscopy, and is associated with increased adenoma detection rates. Furthermore, it is commonly used to help in the delineation and characterization of colorectal neoplasms. However, it usually requires the use of a spraying catheter that decreases the suction capacity of the endoscope, and is time- consuming. Herein, we report on the feasibility of indigo carmine chromoendoscopy during colonoscopy without using a spraying catheter, with the dye being administered through the air/water channel of the endoscope. Since the suction channel remains free, the air can be exsufflated and the staining then applies uniformly onto the colonic walls with the excess indigocarmine dye being immediately eliminated. In our experience with various types of colonoscopes and cap-assisted colonoscopy, this procedure makes indigocarmine chromoendoscopy much easier and quicker to perform, and might save the use of a spray catheter.
Toward an easier indigocarmine chromoendoscopy
Barret, Maximilien; Camus, Marine; Leblanc, Sarah; Coriat, Romain; Prat, Frédéric; Chaussade, Stanislas
2015-01-01
Indigocarmine chromoendoscopy has been proven to improve the detection of colonic lesions during screening colonoscopy, and is associated with increased adenoma detection rates. Furthermore, it is commonly used to help in the delineation and characterization of colorectal neoplasms. However, it usually requires the use of a spraying catheter that decreases the suction capacity of the endoscope, and is time- consuming. Herein, we report on the feasibility of indigo carmine chromoendoscopy during colonoscopy without using a spraying catheter, with the dye being administered through the air/water channel of the endoscope. Since the suction channel remains free, the air can be exsufflated and the staining then applies uniformly onto the colonic walls with the excess indigocarmine dye being immediately eliminated. In our experience with various types of colonoscopes and cap-assisted colonoscopy, this procedure makes indigocarmine chromoendoscopy much easier and quicker to perform, and might save the use of a spray catheter. PMID:26191349
Landsliding in partially saturated materials
Godt, J.W.; Baum, R.L.; Lu, N.
2009-01-01
[1] Rainfall-induced landslides are pervasive in hillslope environments around the world and among the most costly and deadly natural hazards. However, capturing their occurrence with scientific instrumentation in a natural setting is extremely rare. The prevailing thinking on landslide initiation, particularly for those landslides that occur under intense precipitation, is that the failure surface is saturated and has positive pore-water pressures acting on it. Most analytic methods used for landslide hazard assessment are based on the above perception and assume that the failure surface is located beneath a water table. By monitoring the pore water and soil suction response to rainfall, we observed shallow landslide occurrence under partially saturated conditions for the first time in a natural setting. We show that the partially saturated shallow landslide at this site is predictable using measured soil suction and water content and a novel unified effective stress concept for partially saturated earth materials. Copyright 2009 by the American Geophysical Union.
A Brief History of Two Common Surgical Drains.
Meyerson, Joseph M
2016-01-01
The use of surgical drains is commonplace in all types of surgical procedures, and rarely do we take the time to contemplate or investigate the origins of these critical devices. Every surgeon should be familiar with the Jackson-Pratt drain and Blake drain, 2 of the most frequently used closed suction, negative-pressure drainage devices in surgery. These drains are used throughout the body in a wide variety of surgical procedures. The development and differences between these 2 devices are seldom known by the practicing surgeon. In this article, we delve into the ancient history of drains, the creation and alterations of the closed suction, negative-pressure drain that paved the way for the Jackson-Pratt and Blake drain. Finally, we will discuss the variety of reservoirs that attach to these drains and the origin of the well-known adage of when to pull a drain.
Chest Tube Management after Surgery for Pneumothorax.
Pompili, Cecilia; Salati, Michele; Brunelli, Alessandro
2017-02-01
There is scant evidence on the management of chest tubes after surgery for pneumothorax. Most of the current knowledge is extrapolated from studies performed on subjects with lung cancer. This article reviews the existing literature with particular focus on the effect of suction and no suction on the duration of air leak after lung resection and surgery for pneumothorax. Moreover, the role of regulated suction, which seems to provide some benefit in reducing pneumothorax recurrence after bullectomy and pleurodesis, is discussed. Finally, a personal view on the management of chest tubes after surgery for pneumothorax is provided. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Isaev, S. A.; Baranov, P. A.; Sudakov, A. G.; Popov, I. A.; Usachov, A. E.
2017-12-01
Calculations using multiblock computational technologies and a model of shear-stress transport modified with allowance for the curvature of streamlines in turbulent airflow were performed at a zero angle of attack for a semicircular airfoil containing one or two surface vortex cells with slot suction. The results showed evidence of stabilization of a nearly undetached flow and attainment of an extremal lift of C y = 5.2 and a lift-to-drag ratio of K = 24 with allowance for energy losses for suction in the vortex cells.
PIV Measurements of Gas Flow Fields from Burning End
NASA Astrophysics Data System (ADS)
Huang, Yifei; Wu, Junzhang; Zeng, Jingsong; Tang, Darong; Du, Liang
2017-12-01
To study the influence of cigarette gas on the environment, it is necessary to know the cigarette gas flow fields from burning end. By using PIV technique, in order to reveal velocity characteristics of gas flow fields, the velocities of cigarette gas flow fields was analyzed with different stepping motor frequencies corresponding to suction pressures, and the trend of velocity has been given with image fitting. The results shows that the velocities of the burning end increased with suction pressures; Between velocities of the burning end and suction pressures, the relations present polynomial rule; The cigarette gas diffusion in combustion process is faster than in the smoldering process.
NASA Technical Reports Server (NTRS)
Carter, J. E.
1977-01-01
A computer program called STAYLAM is presented for the computation of the compressible laminar boundary-layer flow over a yawed infinite wing including distributed suction. This program is restricted to the transonic speed range or less due to the approximate treatment of the compressibility effects. The prescribed suction distribution is permitted to change discontinuously along the chord measured perpendicular to the wing leading edge. Estimates of transition are made by considering leading edge contamination, cross flow instability, and instability of the Tollmien-Schlichting type. A program listing is given in addition to user instructions and a sample case.
Transport suction apparatus and absorption materials evaluation
NASA Technical Reports Server (NTRS)
Krupa, Debra T.; Gosbee, John
1991-01-01
The specific objectives were as follows. The effectiveness and function was evaluated of the hand held, manually powered v-vac for suction during microgravity. The function was evaluated of the battery powered laerdal suction unit in microgravity. The two units in control of various types of simulated bodily fluids were compared. Various types of tubing and attachments were evaluated which are required to control the collection of bodily fluids during transport. Various materials were evaluated for absorption of simulated bodily fluids. And potential problems were identified for waste management and containment of secretions and fluids during transport. Test procedures, results, and conclusions are briefly discussed.
Effect of the tubular-fan drum shapes on the performance of cleaning head module
NASA Astrophysics Data System (ADS)
Hong, C. K.; Y Cho, M.; Kim, Y. J.
2013-12-01
The geometrical effects of a tubular-fan drum on the performance improvement of the cleaning head module of a vacuum cleaner were investigated. In this study, the number of blades and the width of the blade were selected as the design parameters. Static pressure, eccentric vortex, turbulence kinetic energy (TKE) and suction efficiency were analysed and tabulated. Three-dimensional computational fluid dynamics method was used with an SST (Shear Stress Transfer) turbulence model to simulate the flow field at the suction of the cleaning head module using the commercial code ANSYS-CFX. Suction pressure distributions were graphically depicted for different values of the design parameters.
Development of an Inlet Pressure Sensor for Control in a Left Ventricular Assist Device
Fritz, Bryan; Cysyk, Joshua; Newswanger, Ray; Weiss, William; Rosenberg, Gerson
2010-01-01
A Tesla type continuous flow left ventricular assist device (VAD) has been designed by Penn State and Advanced Bionics, Inc. (ABI). When a continuous flow device is employed, care must be taken to limit low pressures in the ventricle that can produce an obstruction to the inlet cannula or trigger arrhythmias. Design of an inexpensive, semi-conductor strain gage inlet pressure sensor to detect suction has been completed. The research and design analysis included finite element modeling of the sensing region. Sensitivity, step-response, temperature dependence and hysteresis tests have been performed on prototype units. All sensors were able to withstand the maximum expected strain of 82 μin/in at 500 mmHg internal pressure. Average sensitivity was 0.52 ±0.24 μV/mmHg with 0.5 V excitation (n=5 units). Step response time for a 0 to 90 mmHg step change averaged 22 milliseconds. Hysteresis was measured by applying and holding 75mmHg internal pressure for 4 hours, followed by a zero pressure measurement, and ranged from -15 mmHg to 4.1 mmHg (n=3 units). Offset drift varied between 180 and -140 mmHg over a four week period. (n=2 units). Span temperature sensitivity ranged from 18 to -21 μV/°C (n=5 units). Gain temperature sensitivity ranged from -7.4 to 4.9 μV/°C (n=5 units). With the inherent drift, it is currently not possible to use the transducer to measure actual pressures, but it can easily be used to measure pressure changes throughout the cardiac cycle. This signal can then be used in the control system to avoid ventricular suction events. PMID:20335797
Malloch, G; Highet, F; Kasprowicz, L; Pickup, J; Neilson, R; Fenton, B
2006-12-01
The peach-potato aphid Myzus persicae (Sulzer) is an important vector of plant viruses. A network of suction traps collects aerial samples of this aphid in order to monitor and help predict its spatial distribution and likely impact on virus transmission in crops. A suction trap catch is thought to be a good representation of the total aphid pool. Sensitive molecular markers have been developed that determine the genetic composition of the M. persicae population. In Scotland, UK, these were applied to field collections revealing a limited number of clones. Molecular markers are less successful when applied to specimens that have been preserved in an ethanol-based trap fluid designed to preserve morphology. An assessment of different DNA extraction and PCR techniques is presented and the most efficient are used to analyse M. persicae specimens caught in the Dundee suction trap in 2001, a year when exceptionally high numbers were caught. The results reveal that the majority of the M. persicae caught belonged to two highly insecticide resistant clones. In addition, it was possible to compare the relative frequencies of genotypes caught in the trap with those collected at insecticide treated and untreated field sites in the vicinity. These results indicate that, in addition to suction trap data, the ability to sample field sites provides valuable early warning data which have implications for pest control and virus management strategies.
Hydrological monitoring of a natural slope covered with loose granular pyroclastic deposits
NASA Astrophysics Data System (ADS)
Damiano, Emilia; Greco, Roberto; Guida, Andrea; Olivares, Lucio; Picarelli, Luciano
2010-05-01
Mountainous areas of Northern Campania, Southern Italy, are characterised by steep slopes covered with loose volcanic ashes, with very high porosity (ranging between 0.70 and 0.75), laying above a calcareous bedrock. Slope inclination is often larger than internal friction angle of such ashes (around 38°), thus equilibrium is assured by the contribution of apparent cohesion due to soil suction in unsaturated conditions. That is why, during intense and persistent rainfall events, when soil approaches saturation and consequently suction decreases, shallow landslides are frequently triggered. The physical characteristics of involved soils are such that landslides often evolve in form of debris flows, which cause huge damages to buildings and infrastructures and, in some cases, even casualties. Field hydrological monitoring is essential to develop reliable models of slope response to rainfall infiltration, allowing to define triggering conditions of landslides. An automatic monitoring station has been recently installed at the slope of Cervinara, 30 km East of Naples, where a catastrophic landslide occurred in December 1999. The station consists of a tipping bucket rain gauge, with a sensitivity to rainfall height of 0.2mm; four jet fill tensiometers, for the measurement of soil suction at the depths of 10cm, 40cm, 120cm and 160cm below ground surface; four time domain reflectometry probes of various lengths, connected through a multiplexer to a reflectometer, for the measurement of water content profile from ground surface up to a depth of 160cm. All the sensors are connected to a datalogger for the automatic acquisition at hourly frequency of experimental data. Acquired data are then stored into a magnetic memory which is periodically downloaded into a PC. The entire station is operated by a lithium battery connected to a solar panel. The first collected experimental data confirm the usefulness of simultaneous monitoring, at high temporal resolution, of rainfall height, soil suction and soil water content for a better understanding of slope infiltration processes.
Possibility of cross-contamination between dental patients by means of the saliva ejector.
Watson, C M; Whitehouse, R L
1993-04-01
Concern about cross-contamination between dental patients prompted investigation of current suctioning practices. The possibility of the suck-back phenomenon and the presence of oral bacteria in vacuum lines were studied, and dental offices were surveyed concerning the use and disinfection of suction equipment.
Instruction Workbook for Tracheostomy Suctioning and Misting in a School Setting.
ERIC Educational Resources Information Center
Wolf, Karen McKinney; Roach, Antionette Andolfatto
The handbook presents California guidelines for training school personnel to provide skilled nursing procedures such as tracheostomy suctioning and misting for students with special health needs. The workbook begins with an overview of the anatomy and function of the respiratory system, specifically breathing mechanics. Part 2 considers the…
USDA-ARS?s Scientific Manuscript database
A three-year study was conducted to compare temperature profiles in the headspace and in the bulk mass of wheat aerated through pressure aeration and suction aeration. Insect pitfall traps were used to measure naturally-occurring populations of stored product insects. Results show uniform distributi...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
21 CFR 878.4680 - Nonpowered, single patient, portable suction apparatus.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonpowered, single patient, portable suction apparatus. 878.4680 Section 878.4680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878...
Twin-spool turbopumps for ''low'' net positive suction pressure operations
NASA Technical Reports Server (NTRS)
Bair, E. K.; Campbell, W. E.; Ford, O. I.
1970-01-01
Modified single-shaft turbopump incorporates inducer and main pump, each separately driven at different speeds through coaxial-shaft arrangement. Inducer operates at low speed for low net positive suction pressure, main pump operates at high speed to generate high pressure. This arrangement requires no external control for the inducer.
ANNULAR IMPACTOR SAMPLING DEVICE
Tait, G.W.C.
1959-03-31
A high-rate air sampler capable of sampling alphaemitting particles as small as 0.5 microns is described. The device is a cylindrical shaped cup that fits in front of a suction tube and which has sticky grease coating along its base. Suction forces contaminated air against the periodically monitored particle absorbing grease.
NASA Astrophysics Data System (ADS)
Shevchenko, I. V.; Rogalev, A. N.; Garanin, I. V.; Vegera, A. N.; Kindra, V. O.
2017-11-01
The serpentine-like one and half-pass cooling channel systems are primarily used in blades fabricated by the lost-wax casting process. The heat transfer turbulators like cross-sectional or angled ribs used in channels of the midchord region failed to eliminate the temperature irregularity from the suction and pressure sides, which is reaching 200°C for a first stage blade of the high-pressure turbine for an aircraft engine. This paper presents the results of a numerical and experimental test of an advanced heat transfer augmentation system in radial channels developed for alignment of the temperature field from the suction and pressure sides. A numerical simulation of three-dimensional coolant flow for a wide range of Reynolds numbers was carried out using ANSYS CFX software. Effect of geometrical parameters on the heat removal asymmetry was determined. The test results of a blade with the proposed intensification system conducted in a liquid-metal thermostat confirmed the accuracy of calculations. Based on the experimental data, the dependencies for calculation of heat transfer coefficients to the cooling air in the blade studied were obtained.
Effect of velocity and temperature distribution at the hole exit on film cooling of turbine blades
NASA Technical Reports Server (NTRS)
Garg, Vijay K.; Gaugler, Raymond E.
1995-01-01
An existing three-dimensional Navier-Stokes code, modified to include film cooling considerations, has been used to study the effect of coolant velocity and temperature distribution at the hole exit on the heat transfer coefficient on three-film-cooled turbine blades, namely, the C3X vane, the VKI rotor, and the ACE rotor. Results are also compared with the experimental data for all the blades. Moreover, Mayle's transition criterion, Forest's model for augmentation of leading edge heat transfer due to freestream turbulence, and Crawford's model for augmentation of eddy viscosity due to film cooling are used. Use of Mayle's and Forest's models is relevant only for the ACE rotor due to the absence of showerhead cooling on this rotor. It is found that, in some cases, the effect of distribution of coolant velocity and temperature at the hole exit can be as much as 60% on the heat transfer coefficient at the blade suction surface, and 50% at the pressure surface. Also, different effects are observed on the pressure and suction surface depending upon the blade as well as upon the hole shape, conical or cylindrical.
Aircraft energy efficiency laminar flow control glove flight conceptual design study
NASA Technical Reports Server (NTRS)
Wright, A. S.
1979-01-01
A laminar flow control glove applied to the wing of a short to medium range jet transport with aft mounted engines was designed. A slotted aluminum glove concept and a woven stainless steel mesh porous glove concept suction surfaces were studied. The laminar flow control glove and a dummy glove with a modified supercritical airfoil, ducting, modified wing leading and trailing edges, modified flaps, and an LFC trim tab were applied to the wing after slot spacing suction parameters, and compression power were determined. The results show that a laminar flow control glove can be applied to the wing of a jet transport with an appropriate suction system installed.
Rotating flow of a nanofluid due to an exponentially stretching surface with suction
NASA Astrophysics Data System (ADS)
Salleh, Siti Nur Alwani; Bachok, Norfifah; Arifin, Norihan Md
2017-08-01
An analysis of the rotating nanofluid flow past an exponentially stretched surface with the presence of suction is studied in this work. Three different types of nanoparticles, namely, copper, titania and alumina are considered. The system of ordinary differential equations is computed numerically using a shooting method in Maple software after being transformed from the partial differential equations. This transformation has considered the similarity transformations in exponential form. The physical effect of the rotation, suction and nanoparticle volume fraction parameters on the rotating flow and heat transfer phenomena is investigated and has been described in detail through graphs. The dual solutions are found to appear when the governing parameters reach a certain range.
Internal cooling circuit for gas turbine bucket
Hyde, Susan Marie; Davis, Richard Mallory
2005-10-25
In a gas turbine bucket having a shank portion and an airfoil portion having leading and trailing edges and pressure and suction sides, an internal cooling circuit, the internal cooling circuit having a serpentine configuration including plural radial outflow passages and plural radial inflow passages, and wherein a coolant inlet passage communicates with a first of the radial outflow passages along the trailing edge, the first radial outflow passage having a plurality of radially extending and radially spaced elongated rib segments extending between and connecting the pressure and suction sides in a middle region of the first passage to prevent ballooning of the pressure and suction sides at the first radial outflow passage.
Design of Airport Pavements for Expansive Soils.
1981-01-01
8217. . C.Iqt N. - DOT 7 "//-;-31/2I...... , _Ai --i/ 6Z/ ,d, ,-,,’/Design of Airport Pavements for Expansive Soils. JanLapy 1981 6. Per.omingOvgn,, en Code...L/)- V) 3 00L C)- LO en id ’NUN 51J. filter paper (next to the top of the sample) was used as the measure of soil suction. The second filter paper...8217 SITE 4 2 2 3 4 SUCTION, pF FIGURE 4-18. VARIATION OF SUCTION DURING RECHARGE AT DFW. 69 lij ’I41d3U IJ 6id3a LhLO U.. to U.. C.-9 en C, 00 ’U- LA jto
Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension.
Chino, N; Pearson, J R; Cockrell, J L; Mikishko, H A; Koepke, G H
1975-01-01
Negative pressures in the small space between the distal stump and the below-knee prosthetic socket were measured during swing phase for a series of nine subjects. A molded rubber sleeve connecting the prosthesis and the thigh was found to enhance this effect so that suction suspension occurred during the entire swing phase. Deterioration of the suction occurred when the sleeve was intentionally pierced, and when other suspensions such as a suprapatellar cuff or thigh band were tested. The findings indicate that the total-contact socket, gel liner and elastic sleeve combine to create suction in the below-knee socket which improves overall comfort and function for the patient in using the prosthesis.
Numerical investigations of shock wave interaction with laminar boundary layer on compressor profile
NASA Astrophysics Data System (ADS)
Piotrowicz, M.; Flaszyński, P.
2016-10-01
The investigation of shockwave boundary layer interaction on suction side of transonic compressor blade is one of main objectives of TFAST project (Transition Location Effect on Shock Wave Boundary Layer Interaction). In order to look more closely into the flow structure on suction side of a profile, a design of generic test section in linear transonic wind tunnel was proposed. The experimental and numerical results of flow structure on a suction side of the compressor profile investigations are presented. The numerical simulations are carried out for EARSM (Explicit Algebraic Reynolds Stress Model) turbulence model with transition model. The result are compared with oil flow visualisation, schlieren pictures, Pressure Sensitive Paint (PSP) and static pressure.
NASA Technical Reports Server (NTRS)
Smith, A.; Poll, D. I. A.
1998-01-01
Experiments have been performed on an untapered, swept cylinder model in the Cranfield College of Aeronautics 8 ft x 6 ft low-speed wind tunnel to investigate the effect of surface transpiration on the process of relaminarization in the attachment-line boundary layer. Suction coefficients for complete suppression of turbulence were determined as a function of Reynolds number and spanwise distance. The effect of attachment-line suction on the spanwise propagation of gross disturbances emanating from the fuselage-wing junction region was also studied. Finally, the effect of blowing on a laminar attachment-line boundary layer was also considered and excellent agreement was achieved with previous studies.
NASA Astrophysics Data System (ADS)
Xu, Cheng; Amano, Ryoichi Samuel; Lee, Eng Kwong
A 1.829m (6ft) diameter industrial large flow-rate axial fan operated at 1770rpm was studied experimentally in laboratory conditions. The flow characteristics on the fan blade surfaces were investigated by measuring the pressure distributions on the blade suction and pressure surfaces and the results were discussed by comparing with analytical formulations and CFD. Flow visualizations were also performed to validate the flow characteristics near the blade surface and it was demonstrated that the flow characteristics near the fan blade surface were dominated by the centrifugal force of the fan rotation which resulted in strong three-dimensional flows. The time-dependent pressure measurement showed that the pressure oscillations on the fan blade were significantly dominated by vortex shedding from the fan blades. It was further demonstrated that the pressure distributions during the fan start-up were highly unsteady, and the main frequency variation of the static pressure was much smaller than the fan rotational frequency. The time-dependent pressure measurement when the fan operated at a constant speed showed that the magnitude of the blade pressure variation with time and the main variation frequency was much smaller than the fan rotational frequency. The pressure variations that were related to the vortex shedding were slightly smaller than the fan rotational frequency. The strain gages were used to measure the blade stress and the results were compared with FEA results.
How propeller suction is the dominant factor for ship accidents at shallow water conditions
NASA Astrophysics Data System (ADS)
Acar, Dursun; Alpar, Bedri; Ozeren, Sinan
2017-04-01
The laminar flow comes to the fore with the disappearance of the several other directions in the internal displacements in the water current. Due to the dominant speed direction during the straightforward motion of the ship, the underwater hull is associated with the continuous flow of laminar currents. The open marine environment acts as a compressible liquid medium because of the presence of many variables about water volume overflow boundaries where the ship is associated. Layers of water rising over the sea surface due to ship's body and the propeller's water push provides loss of liquid lifting force for the ship. These situations change the well-known sea-floor morphology and reliable depth limits, and lead to probable accidents. If the ship block coefficient for the front side is 0.7 or higher, the "squat" will be more on the bow, because the associated factor "displacement volume" causes to the low-pressure environment due to large and rapid turbulence. Thus, the bow sinks further, which faced with liquid's weaker lift force. The vessels Gerardus Mercator, Queen Elizabeth and Costa Concordia had accidents because of unified reasons of squat, fast water mass displacement by hull push and propeller suction interaction. In the case of water mass displacement from the bow side away, that accident occurred in 2005 by the vessel Gerardus Mercator with excessive longitudinal trim angularity in the shallow water. The vessel Costa Concordia (2012), voluminous water displaced from the rear left side was an important factor because of the sharp manoeuvre of that the captain made before the accident. Observations before the accident indicate that full-speed sharp turn provided listed position for the ship from left (port side) in the direction of travel before colliding and then strike a rock on the sloping side of the seabed. The reason why the ship drifted to the left depends mainly the water discharge occurred at the left side of the hull during left-hand rudder control. Additionally the second water drainage from the shallow ridge area by the propeller's left-directed suction created a shallower environment. Similar situation for example collision of two ships during their side by side forward motions; their positions will be approached and listed to each other more same as downslope movement because of the shared area's water level collapse occur more by two propeller's suction.
78 FR 39571 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-02
... 2800, Aircraft Fuel System. (e) Unsafe Condition This AD was prompted by reports of two in-service... system, followed by loss of fuel system suction feed capability on one engine, and in-flight shutdown of... and correct loss of the engine fuel suction feed capability of the fuel system, which, in the event of...
77 FR 41934 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-17
... Transport Association (ATA) of America Code 2800, Aircraft Fuel System. (e) Unsafe Condition This AD was... operational tests of the engine fuel suction feed of the fuel system, and other related testing if necessary... loss of boost pump pressure of the fuel feed system, followed by loss of fuel system suction feed...
2017-11-13
information and proposes a series of findings and recommendations to improved airway management in the prehospital combat environment. The key...Airway Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries...75 General Information and Device Usability
Three scales of motions associated with tornadoes. [Cyclones, tornadoes, and suction vortexs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forbes, G.S.
1978-03-01
This dissertation explores three scales of motion commonly associated with tornadoes, and the interaction of these scales: the tornado cyclone, the tornado, and the suction vortex. The goal of the research is to specify in detail the character and interaction of these scales of motion to explain tornadic phenomena.
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
... emergency electrical power generator. Pipeline facilities required for the project include approximately 545 feet of new 36-inch- diameter suction and discharge pipelines which would connect the compressor... pipeline located between the new suction and discharge pipelines. The FERC staff mailed copies of the EA to...
A Force-Visualized Silicone Retractor Attachable to Surgical Suction Pipes.
Watanabe, Tetsuyou; Koyama, Toshio; Yoneyama, Takeshi; Nakada, Mitsutoshi
2017-04-05
This paper presents a force-visually-observable silicone retractor, which is an extension of a previously developed system that had the same functions of retracting, suction, and force sensing. These features provide not only high usability by reducing the number of tool changes, but also a safe choice of retracting by visualized force information. Suction is achieved by attaching the retractor to a suction pipe. The retractor has a deformable sensing component including a hole filled with a liquid. The hole is connected to an outer tube, and the liquid level displaced in proportion to the extent of deformation resulting from the retracting load. The liquid level is capable to be observed around the surgeon's fingertips, which enhances the usability. The new hybrid structure of soft sensing and hard retracting allows the miniaturization of the retractor as well as a resolution of less than 0.05 N and a range of 0.1-0.7 N. The overall structure is made of silicone, which has the advantages of disposability, low cost, and easy sterilization/disinfection. This system was validated by conducting experiments.
Primary Total Knee Replacement: Is Suction a Portal of Infection?
Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W
2009-01-01
INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972
F-16XL Wing Pressure Distributions and Shock Fence Results from Mach 1.4 to Mach 2.0
NASA Technical Reports Server (NTRS)
Landers, Stephen F.; Saltzman, John A.; Bjarke, Lisa J.
1997-01-01
Chordwise pressure distributions were obtained in-flight on the upper and lower surfaces of the F-16XL ship 2 aircraft wing between Mach 1.4 and Mach 2.0. This experiment was conducted to determine the location of shock waves which could compromise or invalidate a follow-on test of a large chord laminar flow control suction panel. On the upper surface, the canopy closure shock crossed an area which would be covered by a proposed laminar flow suction panel. At the laminar flow experiment design Mach number of 1.9, 91 percent of the suction panel area would be forward of the shock. At Mach 1.4, that value reduces to 65 percent. On the lower surface, a shock from the inlet diverter would impinge on the proposed suction panel leading edge. A chordwise plate mounted vertically to deflect shock waves, called a shock fence, was installed between the inlet diverter and the leading edge. This plate was effective in reducing the pressure gradients caused by the inlet shock system.
Analysis of Infiltration-Suction Response in Unsaturated Residual Soil Slope in Gelugor, Penang
NASA Astrophysics Data System (ADS)
Ashraf Mohamad Ismail, Mohd; Hasliza Hamzah, Nur; Min, Ng Soon; Hazreek Zainal Abidin, Mohd; Tajudin, Saiful Azhar Ahmad; Madun, Aziman
2018-04-01
Rainfall infiltration on residual soil slope may impair slope stability by altering the pore-water pressure in the soil. A study has been carried out on unsaturated residual soil slope in Gelugor, Penang to determine the changes in matric suction of residual soils at different depth due to rainwater infiltration. The sequence of this study includes the site investigation, field instrumentation, laboratory experiment and numerical modeling. Void ratio and porosity of soil were found to be decreasing with depth while the bulk density and dry density of soil increased due to lower porosity of soil at greater depth. Soil infiltration rate and matric suction of all depths decrease with the increase of volumetric water content as well as the degree of saturation. Numerical modeling was used to verify and predict the relationship between infiltration-suction response and degree of saturation. Numerical models can be used to integrate the rainfall scenarios into quantitative landslide hazard assessments. Thus, development plans and mitigation measures can be designed for estimated impacts from hazard assessments based on collected data.
NASA Technical Reports Server (NTRS)
Orlando, A. F.; Moffat, R. J.; Kays, W. M.
1974-01-01
The relationship between the turbulent transport of heat and momentum in an adverse pressure gradient boundary layer was studied. An experimental study was conducted of turbulent boundary layers subject to strong adverse pressure gradients with suction. Near-equilibrium flows were attained, evidenced by outer-region similarity in terms of defect temperature and defect velocity profiles. The relationship between Stanton number and enthalpy thickness was shown to be the same as for a flat plate flow both for constant wall temperature boundary conditions and for steps in wall temperature. The superposition principle used with the step-wall-temperature experimental result was shown to accurately predict the Stanton number variation for two cases of arbitrarily varying wall temperature. The Reynolds stress tensor components were measured for strong adverse pressure gradient conditions and different suction rates. Two peaks of turbulence intensity were found: one in the inner and one in the outer regions. The outer peak is shown to be displaced outward by an adverse pressure gradient and suppressed by suction.
LES-based characterization of a suction and oscillatory blowing fluidic actuator
NASA Astrophysics Data System (ADS)
Kim, Jeonglae; Moin, Parviz
2015-11-01
Recently, a novel fluidic actuator using steady suction and oscillatory blowing was developed for control of turbulent flows. The suction and oscillatory blowing (SaOB) actuator combines steady suction and pulsed oscillatory blowing into a single device. The actuation is based upon a self-sustained mechanism of confined jets and does not require any moving parts. The control output is determined by a pressure source and the geometric details, and no additional input is needed. While its basic mechanisms have been investigated to some extent, detailed characteristics of internal turbulent flows are not well understood. In this study, internal flows of the SaOB actuator are simulated using large-eddy simulation (LES). Flow characteristics within the actuator are described in detail for a better understanding of the physical mechanisms and improving the actuator design. LES predicts the self-sustained oscillations of the turbulent jet. Switching frequency, maximum velocity at the actuator outlets, and wall pressure distribution are in good agreement with the experimental measurements. The computational results are used to develop simplified boundary conditions for numerical experiments of active flow control. Supported by the Boeing company.
Discharge of thoracic patients on portable digital suction: Is it cost-effective?
Southey, Dawn; Pullinger, Diane; Loggos, Spiros; Kumari, Nelam; Lengyel, Emma; Morgan, Ian; Yiu, Patrick; Nandi, Jayanta; Luckraz, Heyman
2015-09-01
A portable suction drainage device for patients undergoing thoracic surgical procedures was introduced into our service in January 2010. Patients who met strict discharge criteria were allowed to continue their treatment at home with the device. They were monitored in a designated follow-up clinic. Data were collected to identify the impact of this service in relation to the duration of follow-up required, bed-days saved, and potential cost/benefits. All patients who underwent a thoracic procedure from March 2012 to April 2014 and required suction postoperatively for air leak were included in the study. Patients were identified as suitable according to the discharge criteria. Data regarding patient demographics were collected prospectively on the thoracic database, and data on the drainage device were logged in a specific data sheet. Visits to the follow-up clinic were also recorded. During the study period, 50 patients stayed a total 1125 days on the portable suction system. Twenty were discharged home, equating to 772 bed-days saved (GBP 270,000 cost-saving). Clinic attendance totalled 162 visits (GBP 24,300 cost reimbursement for attendance). Six (30%) patients were readmitted on 9 occasions due to device malfunction or inability to cope at home. Careful identification of patients suitable for discharge with a portable suction device achieved a significant cost-saving and freed hospital beds, thus allowing increased surgical activity. Patients were also able to be cared for within their home environment and maintain their quality of life. © The Author(s) 2015.
Mahmoodpoor, Ata; Hamishehkar, Hadi; Hamidi, Masoud; Shadvar, Kamran; Sanaie, Sarvin; Golzari, Samad Ej; Khan, Zahid Hussain; Nader, Nader D
2017-04-01
Endotracheal tube placement is necessary for the control of the airway in patients who are mechanically ventilated. However, prolonged duration of endotracheal tube placement contributes to the development of ventilator-associated pneumonias (VAPs). The aim of this study was to evaluate whether subglottic suctioning using TaperGuard EVAC tubes was effective in decreasing the frequency of VAP. A total of 276 mechanically ventilated patients for more than 72 hours were randomly assigned to group E (EVAC tube) and group C (conventional tube). All patients received routine care including VAP prevention measures during their intensive care unit stay. In group E, subglottic suctioning was performed every 6 hours. Outcome variables included incidence VAP, intensive care unit length of stay, and mortality. Frequency of intraluminal suction, mechanical ventilation-free days, reintubation, the ratio of arterial oxygen partial pressure to fractional inspired oxygen and mortality rate were similar between the 2 groups (P > .05). The mean cuff pressure in group E was significantly less than that in group C (P < .001). Ventilator-associated pneumonia was significantly less in group E compared with group C (P = .015). The use of intermittent subglottic secretion suctioning was associated with a significant decrease in the incidence of the VAP in critically ill patients. However, larger multicenter trials are required to arrive at a concrete decision on routine usage of TaperGuard tubes in critical care settings. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, N., E-mail: nirupamd@barc.gov.in; Sengupta, P.; Abraham, G.
Highlights: • Grain refinement was made in Zr–16 wt.% SS alloy while prepared by suction casting process. • Distribution of Laves phase, e.g., Zr{sub 2}(Fe, Cr) was raised in suction cast (SC) Zr–16 wt.% SS. • Corrosion resistance was improved in SC alloy compared to that of arc-melt-cast alloy. • Grain refinement in SC alloy assisted for an increase in its corrosion resistance. - Abstract: Zirconium (Zr)-stainless steel (SS) hybrid alloys are being considered as baseline alloys for developing metallic-waste-form (MWF) with the motivation of disposing of Zr and SS base nuclear metallic wastes. Zr–16 wt.% SS, a MWF alloymore » optimized from previous studies, exhibit significant grain refinement and changes in phase assemblages (soft phase: Zr{sub 2}(Fe, Cr)/α-Zr vs. hard phase: Zr{sub 3}(Fe, Ni)) when prepared by suction casting (SC) technique in comparison to arc-cast-melt (AMC) route. Variation in Cr-distribution among different phases are found to be low in suction cast alloy, which along with grain refinement restricted Cr-depletion at the Zr{sub 2}(Fe, Cr)/Zr interfaces, prone to localized attack. Hence, SC alloy, compared to AMC alloy, showed lower current density, higher potential at the breakdown of passivity and higher corrosion potential during polarization experiments (carried out under possible geological repository environments, viz., pH 8, 5 and 1) indicating its superior corrosion resistance.« less
Immediate newborn care practices delay thermoregulation and breastfeeding initiation
Sobel, Howard L; Silvestre, Maria Asuncion A; Mantaring, Jacinto Blas V; Oliveros, Yolanda E; Nyunt-U, Soe
2011-01-01
Aim A deadly nosocomial outbreak in a Philippine hospital drew nationwide attention to neonatal sepsis. Together with specific infection control measures, interventions that protect newborns against infection-related mortality include drying, skin-to-skin contact, delayed cord clamping, breastfeeding initiation and delayed bathing. This evaluation characterized hospital care in the first hours of life with the intent to drive policy change, strategic planning and hospital reform. Methods Trained physicians observed 481 consecutive deliveries in 51 hospitals using a standardized tool to record practices and timing of immediate newborn care procedures. Results Drying, weighing, eye care and vitamin K injections were performed in more than 90% of newborns. Only 9.6% were allowed skin-to-skin contact. Interventions were inappropriately sequenced, e.g. immediate cord clamping (median 12 sec), delayed drying (96.5%) and early bathing (90.0%). While 68.2% were put to the breast, they were separated two minutes later. Unnecessary suctioning was performed in 94.9%. Doctors trained in neonatal resuscitation were 2.5 (1.1–5.7) times more likely to unnecessarily suction vigorous newborns. Two per cent died and 5.7% developed sepsis/pneumonia. Conclusions This minute-by-minute observational assessment revealed that performance and timing of immediate newborn care interventions are below WHO standards and deprive newborns of basic protections against infection and death. PMID:21375583
Biorobotic adhesion in water using suction cups.
Bandyopadhyay, Promode R; Hrubes, J Dana; Leinhos, Henry A
2008-03-01
Echeneid fish, limpets and octopi use suction cups for underwater adhesion. When echeneid fish use suckers to 'hitch a ride' on sharks (which have riblet-patterned skins), the apparent absence of any pump or plumbing may be an advantage over biorobotic suction cups. An intriguing question is: How do they achieve seemingly persistent leak-free contact at low energy cost over rough surfaces? The design features of their suckers are explored in a biorobotic context of adhesion in water over rough surfaces. We have carried out experiments to compare the release force and tenacity of man-made suction cups with those reported for limpets and echeneid fish. Applied tensile and shear release forces were monotonically increased until release. The effects of cup size and type, host surface roughness, curvature and liquid surface tension have been examined. The flow of water in the sharkskin-like host surface roughness has been characterized. The average tenacity is 5.28 N cm(-2) (sigma = 0.53 N cm(-2), N = 37) in the sub-ambient pressure range of 14.6-49.0 kPa, in man-made cups for monotonically increasing applied release force. The tenacity is lower for harmonically oscillating release forces. The dynamic structural interactions between the suction cup and the oscillating applied forcing are discussed. Inspired by the matching of sharkskin riblet topology in echeneid fish suckers, it was found that biorobotic sealed contact over rough surfaces is also feasible when the suction cup makes a negative copy of the rough host surface. However, for protracted, persistent contact, the negative topology would have to be maintained by active means. Energy has to be spent to maintain the negative host roughness topology to minute detail, and protracted hitch-riding on sharks for feeding may not be free for echeneid fish. Further work is needed on the mechanism and efficiency of the densely populated tiny actuators in the fish suckers that maintain leak-proof contact with minimal energy cost and the feasibility of their biorobotic replication.
Prospective randomized trial compares suction versus water seal for air leaks.
Cerfolio, R J; Bass, C; Katholi, C R
2001-05-01
Surgeons treat air leaks differently. Our goal was to evaluate whether it is better to place chest tubes on suction or water seal for stopping air leaks after pulmonary surgery. A second goal was to evaluate a new classification system for air leaks that we developed. Patients were prospectively randomized before surgery to receive suction or water seal to their chest tubes on postoperative day (POD) #2. Air leaks were described and quantified daily by a classification system and a leak meter. The air-leak meter scored leaks from 1 (least) to 7 (greatest). The group randomized to water seal stayed on water seal unless a pneumothorax developed. On POD #2, 33 of 140 patients had an air leak. Eighteen patients had been preoperatively randomized to water seal and 15 to suction. Air leaks resolved in 12 (67%) of the water seal patients by the morning of POD #3. All 6 patients whose air leak did not stop had a leak that was 4/7 or greater (p < 0.0001) on the leak meter. Of the 15 patients randomized to suction, only 1 patient's air leak (7%) resolved by the morning of POD #3. The randomization aspect of the trial was ended and statistical analysis showed water seal was superior (p = 0.001). The remaining 14 patients were then placed to water seal and by the morning of POD #4, 13 patients' leaks had stopped. Of the 32 total patients placed to seal, 7 (22%) developed a pneumothorax and 6 of these 7 patients had leaks that were 4/7 or greater (p = 0.001). Placing chest tubes on water seal seems superior to wall suction for stopping air leaks after pulmonary resection. However, water seal does not stop expiratory leaks that are 4/7 or greater. Pneumothorax may occur when chest tubes are placed on seal with leaks this large.
Corley, Amanda; Sharpe, Nicola; Caruana, Lawrence R; Spooner, Amy J; Fraser, John F
2014-04-01
Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleaning and to determine whether these changes were preventable using a CSC with a valve in situ between the airway and catheter cleaning chamber. This prospective randomized crossover study was conducted in a metropolitan tertiary ICU. Ten patients mechanically ventilated via volume-controlled synchronized intermittent mandatory ventilation (SIMV-VC) and requiring manual hyperinflation (MHI) were included in this study. CSC cleaning was performed using 2 different brands of CSC (one with a valve [Ballard Trach Care 72, Kimberly-Clark, Roswell, Georgia] and one without [Portex Steri-Cath DL, Smiths Medical, Dublin, Ohio]). The maneuvers were performed during both SIMV-VC and MHI. Lung volume change was measured via impedance change using electrical impedance tomography. A mixed model was used to compare the estimated means. During cleaning of the valveless CSC, significant decreases in lung impedance occurred during MHI (-2563 impedance units, 95% CI 2213-2913, P < .001), and significant increases in lung impedance occurred during SIMV (762 impedance units, 95% CI 452-1072, P < .001). In contrast, cleaning of the CSC with a valve in situ resulted in non-significant lung volume changes and maintenance of normal ventilation during MHI and SIMV-VC, respectively (188 impedance units, 95% CI -136 to 511, P = .22; and 22 impedance units, 95% CI -342 to 299, P = .89). When there is no valve between the airway and suction catheter, cleaning of the CSC results in significant derangements in lung volume. Therefore, the presence of such a valve should be considered essential in preserving lung volumes and uninterrupted ventilation in mechanically ventilated patients.
Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam
2018-03-11
Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Menaceur, Hamza; Delage, Pierre; Tang, Anh Minh; Talandier, Jean
2016-12-01
The Callovo-Oxfordian (COx) claystone is considered in France as a possible host rock for the disposal of high-level long-lived radioactive waste at great depth. During the operational phase, the walls of the galleries and of the disposal cells will be successively subjected to desaturation induced by ventilation followed by resaturation once the galleries are closed. To better understand this phenomenon, a sound understanding of the water retention properties of the COx claystone is necessary. Following a previous study by the same group, this paper presents an investigation of microstructure changes in COx claystone under suction changes. Microstructure was investigated by means of mercury intrusion porosimetry tests on freeze-dried specimens previously submitted to various suctions. Along the drying path, the initial microstructure, characterised by a well-classified unimodal pore population around a mean diameter value of 32 nm, slightly changed with the same shape of the PSD curve and slightly moved towards smaller diameters (27-28 nm) at suctions of 150 and 331 MPa, respectively. The infra-porosity too small to be intruded by mercury (diameter smaller than 5.5 nm) reduced from 4.3 to 3.3 %. Oven drying reduced the mean diameter to 20 nm and the infra-porosity to 1 %. Wetting up to 9 MPa suction leads to saturation with no significant change in the PSD curve, whereas wetting at zero suction gave rise to the appearance of a large pore population resulting from the development of cracks with width of several micrometres, together with an enlargement of the initial pore population above the mean diameter. The concepts describing the step hydration of smectites (by the successive placement within the clay platelets along the smectite faces of 1, 2, 3 and 4 layers of water molecules with respect to the suction applied) appeared relevant to better understand the changes in microstructure of the COx claystone under suction changes. This also allowed to better define the status of water in claystones and shales containing smectite, with a distinction made between the water adsorbed within the clay platelets, and the free inter-platelet water involved in hydromechanical couplings through changes in pore pressure and water transfers.
Hydrological effect of vegetation against rainfall-induced landslides
NASA Astrophysics Data System (ADS)
Gonzalez-Ollauri, Alejandro; Mickovski, Slobodan B.
2017-06-01
The hydrological effect of vegetation on rainfall-induced landslides has rarely been quantified and its integration into slope stability analysis methods remains a challenge. Our goal was to establish a reproducible, novel framework to evaluate the hydrological effect of vegetation on shallow landslides. This was achieved by accomplishing three objectives: (i) quantification in situ of the hydrological mechanisms by which woody vegetation (i.e. Salix sp.) might impact slope stability under wetting and drying conditions; (ii) to propose a new approach to predict plant-derived matric suctions under drying conditions; and (iii) to evaluate the suitability of the unified effective stress principle and framework (UES) to quantify the hydrological effect of vegetation against landslides. The results revealed that plant water uptake was the main hydrological mechanism contributing to slope stability, as the vegetated slope was, on average, 12.84% drier and had matric suctions three times higher than the fallow slope. The plant-related mechanisms under wetting conditions had a minimal effect on slope stability. The plant aerial parts intercepted up to 26.73% of the rainfall and concentrated a further 10.78% of it around the stem. Our approach successfully predicted the plant-derived matric suctions and UES proved to be adequate for evaluating the hydrological effect of vegetation on landslides. Although the UES framework presented here sets the basis for effectively evaluating the hydrological effect of vegetation on slope stability, it requires knowledge of the specific hydro-mechanical properties of plant-soil composites and this in itself needs further investigation.
Fiber optic suctioning of urinary stone phantoms during laser lithotripsy
NASA Astrophysics Data System (ADS)
Blackmon, Richard L.; Case, Jason R.; Trammell, Susan R.; Irby, Pierce B.; Fried, Nathaniel M.
2013-03-01
Fiber optic attraction of urinary stones during laser lithotripsy has been previously observed, and this phenomenon may potentially be exploited to pull stones inside the urinary tract without mechanical grasping tools, thus saving the urologist valuable time and space in the ureteroscope's single working channel. In this study, Thulium fiber laser (TFL) high-pulse-rate/low-pulse-energy operation and Holmium:YAG low-pulse-rate/high-pulse-energy operation are compared for fiber optic "suctioning" of Plaster-of-Paris stone phantoms. A TFL with wavelength of 1908 nm, pulse energy of 35 mJ, pulse duration of 500 μs, and pulse rate of 10-350 Hz, and Holmium laser with wavelength of 2120 nm, pulse energy of 35-360 mJ, pulse duration of 300 μs, and pulse rate of 20 Hz were tested using 270-μm-core fibers. A peak "pull" speed of 2.5 mm/s was measured for both TFL (35 mJ and 150-250 Hz) and Holmium laser (210 mJ and 20 Hz). Particle image velocimetry and thermal imaging were used to track water flow for all parameters. Fiber optic suctioning of urinary stone phantoms is feasible for both lasers. However, TFL operation at high-pulse-rates/low-pulse-energies provides faster, smoother stone pulling than Holmium operation at low-pulserates/ high-pulse-energies. After further study, this method may be used to manipulate urinary stones in the clinic.
Prey capture behavior and kinematics of the Atlantic cownose ray, Rhinoptera bonasus.
Sasko, Desirée E; Dean, Mason N; Motta, Philip J; Hueter, Robert E
2006-01-01
The structurally reinforced jaws of the cownose ray, Rhinoptera bonasus testify to this species' durophagous diet of mollusks, but seem ill-suited to the behaviors necessary for excavating such prey. This study explores this discordance by investigating the prey excavation and capture kinematics of R. bonasus. Based on the basal suction feeding mechanism in this group of fishes, we hypothesized a hydraulic method of excavation. As expected, prey capture kinematics of R. bonasus show marked differences relative to other elasmobranchs, relating to prey excavation and use of the cephalic lobes (modified anterior pectoral fin extensions unique to derived myliobatiform rays). Prey are excavated by repeated opening and closing of the jaws to fluidize surrounding sand. The food item is then enclosed laterally by the depressed cephalic lobes, which transport it toward the mouth for ingestion by inertial suction. Unlike in most sharks, upper jaw protrusion and mandibular depression are simultaneous. During food capture, the ray's spiracle, mouth, and gill slit movements are timed such that water enters only the mouth (e.g., the spiracle closes prior to prey capture and reopens immediately following). Indigestible parts are then hydraulically winnowed from edible prey portions, by mouth movements similar to those used in excavation, and ejected through the mouth. The unique sensory/manipulatory capabilities of the cephalic lobes, as well as the cownose ray's hydraulic excavation/winnowing behaviors and suction feeding, make this species an effective benthic predator, despite its epibenthic lifestyle.
Compressibility effects on dynamic stall of airfoils undergoing rapid transient pitching motion
NASA Technical Reports Server (NTRS)
Chandrasekhara, M. S.; Platzer, M. F.
1992-01-01
The research was carried out in the Compressible Dynamic Stall Facility, CDSF, at the Fluid Mechanics Laboratory (FML) of NASA Ames Research Center. The facility can produce realistic nondimensional pitch rates experienced by fighter aircraft, which on model scale could be as high as 3600/sec. Nonintrusive optical techniques were used for the measurements. The highlight of the effort was the development of a new real time interferometry method known as Point Diffraction Interferometry - PDI, for use in unsteady separated flows. This can yield instantaneous flow density information (and hence pressure distributions in isentropic flows) over the airfoil. A key finding is that the dynamic stall vortex forms just as the airfoil leading edge separation bubble opens-up. A major result is the observation and quantification of multiple shocks over the airfoil near the leading edge. A quantitative analysis of the PDI images shows that pitching airfoils produce larger suction peaks than steady airfoils at the same Mach number prior to stall. The peak suction level reached just before stall develops is the same at all unsteady rates and decreases with increase in Mach number. The suction is lost once the dynamic stall vortex or vortical structure begins to convect. Based on the knowledge gained from this preliminary analysis of the data, efforts to control dynamic stall were initiated. The focus of this work was to arrive at a dynamically changing leading edge shape that produces only 'acceptable' airfoil pressure distributions over a large angle of attack range.
Does daily kangaroo care provide sustained pain and stress relief in preterm infants?
Mitchell, A J; Yates, C C; Williams, D K; Chang, J Y; Hall, R Whit
2013-01-01
1. Determine whether stress in preterm infants, measured with salivary cortisol, decreases after five days of Kangaroo Care (KC) compared to five days of Standard Care (SC). 2. To determine whether kangaroo care provides sustainable pain relief beyond the period of skin-to-skin holding. Preterm infants (n = 38) born at 27-30 weeks gestational age were randomized to either the KC or the SC group and received the allocated intervention starting on day of life (DOL) five and continuing for five days. Salivary cortisol was collected on DOL five and again on DOL ten. Differences were analyzed using repeated measures ANOVA and t tests. Pain during nasal suctioning over five days was assessed using the Premature Infant Pain Profile (PIPP). 1. Adequate saliva samples for salivary cortisol were collected for 13 KC infants and 11 SC infants. There was no main effect of group (p = 0.49), but there was a significant main effect of age (DOL five versus DOL ten), with salivary cortisol levels decreasing in both groups (p = 0.02). 2. Pain scores for both groups (n = 38) indicted mild to moderate pain during suctioning, with no significant difference in pain scores between groups. 1. KC did not affect salivary cortisol levels in preterm neonates, but levels in both the KC and SC groups decreased over time from DOL five to ten. Salivary cortisol may vary with age of infant. 2. Infants experience pain during routine suctioning and may require pain management.
Tsang, Lap Fung; Cheng, Hang Cheong; Ho, Hon Shuen; Hsu, Yung Chak; Chow, Chiu Man; Law, Heung Wah; Fong, Lup Chau; Leung, Lok Ming; Kong, Ivy Ching Yan; Chan, Chi Wai; Sham, Alice So Yuen
2016-05-01
Although various drains have long been used in total joint replacement, evidence suggests inconsistent practice exists in the use of drainage systems including intermittently applying suction or free of drainage suction, and variations in the optimal timing for wound drain removal. A comprehensive systematic review of available evidence up to 2013 was conducted in a previous study and a protocol was adapted for clinical application according to the summary of the retrieved information (Tsang, 2015). To determine if the protocol could reduce blood loss and blood transfusion after operation and to develop a record form so as to enhance communication of drainage record amongst surgeons and nurses. A quasi-experimental time-series design was undertaken. In the conventional group, surgeons ordered free drainage if the drain output was more than 300 ml. The time of removal of the drain was based on their professional judgement. In the protocol group the method of drainage was dependant of the drainage output as was the timing of the removal of the drain. A standardized record form was developed to guide operating room and orthopaedic ward nurses to manage the drainage system. The drain was removed significantly earlier in the protocol group. Blood loss rate at the first hour of post-operation was extremely low in the protocol group due to clamping effect. Blood loss in volume during the first three hours in the protocol group was significantly lower than that in the conventional group. Only in 11.1% and 4% of cases was it necessary to clamp at the three and four hour post-operative hours. No clamping was required at the two and eight hour postoperative period. There was no significant difference in blood loss during the removal of the drain and during blood transfusion, which was required for patients upon removal of the drain in the two groups. This is the first clinical study to develop an evidence-based protocol to manage wound drain effectively in Hong Kong. Total blood loss and blood transfusions were not significantly different between the conventional and protocol groups. A standard documentation document is beneficial to enhance communication between doctors and nurses as well as to monitor and observe drainage effectively. Copyright © 2016 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-26
... the NRC's E-Filing system does not support unlisted software, and the NRC Meta System Help Desk will... Osmosis (RO) system borated water storage tank suction connections. Basis for proposed no significant... requirement. For the SFP, the suction to the RO system is above the required TS water level, therefore, the...
46 CFR 182.510 - Bilge piping system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction... meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each... provided. (b) A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less...
46 CFR 182.510 - Bilge piping system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... feet) in length must be not less than 40 millimeters (1.5 inches) nominal pipe size. A bilge suction... meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each... provided. (b) A bilge pipe in a vessel of not more than 19.8 meters (65 feet) in length must be not less...
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
NASA Technical Reports Server (NTRS)
Roache, P. J.
1979-01-01
A summary is given of the attempts made to apply semidirect methods to the calculation of three-dimensional viscous flows over suction holes in laminar flow control surfaces. The attempts were all unsuccessful, due to either (1) lack of resolution capability, (2) lack of computer efficiency, or (3) instability.
21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Non-Powered suction apparatus device intended for negative pressure wound therapy. 878.4683 Section 878.4683 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Non-Powered suction apparatus device intended for negative pressure wound therapy. 878.4683 Section 878.4683 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
21 CFR 878.4683 - Non-Powered suction apparatus device intended for negative pressure wound therapy.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Non-Powered suction apparatus device intended for negative pressure wound therapy. 878.4683 Section 878.4683 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES...
USDA-ARS?s Scientific Manuscript database
Comparative responses of 21 species of mosquitoes to light traps (LT) and suction traps (ST) and captured using the human landing collection method (HL) varied in accordance with collection technique but data analyses for most species revealed significant interaction between collection method and th...
Abdominal drainage following cholecystectomy: high, low, or no suction?
McCormack, T. T.; Abel, P. D.; Collins, C. D.
1983-01-01
A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study failed to demonstrate any clinically useful difference between high negative pressure, low negative pressure, and static drainage system were compared: a simple tube drain, a low negative used, suction is not necessary and a simple tube drain (greater than 6 mm internal diameter) is the most effective form of drainage. PMID:6614773
NASA Technical Reports Server (NTRS)
Holzhauser, Curt A; Bray, Richard S
1956-01-01
An investigation was undertaken to determine the increase in maximum lift coefficient that could be obtained by applying area suction near the leading edge of a wing. This investigation was performed first with a 35 degree swept-wing model in the wind tunnel, and then with an operational 35 degree swept-wing airplane which was modified in accord with the wind-tunnel results. The wind-tunnel and flight tests indicated that the maximum lift coefficient was increased more than 50 percent by the use of area suction. Good agreement was obtained in the comparison of the wind-tunnel results with those measured in flight.
Hysteresis of unsaturated hydromechanical properties of a silty soil
Lu, Ning; Kaya, Murat; Collins, Brian D.; Godt, Jonathan W.
2013-01-01
Laboratory tests to examine hysteresis in the hydrologic and mechanical properties of partially saturated soils were conducted on six intact specimens collected from a landslide-prone area of Alameda County, California. The results reveal that the pore-size distribution parameter remains statistically unchanged between the wetting and drying paths; however, the wetting or drying state has a pronounced influence on the water-entry pressure, the water-filled porosity at zero suction, and the saturated hydraulic conductivity. The suction stress values obtained from the shear-strength tests under both natural moisture and resaturated conditions were mostly bounded by the suction stress characteristic curves (SSCCs) obtained from the hydrologic tests. This finding experimentally confirms that the soil-water retention curve, hydraulic conductivity function, and SSCC are intrinsically related.
NASA Technical Reports Server (NTRS)
Cook, Woodrow L; Anderson, Seth B; Cooper, George E
1958-01-01
A wind-tunnel investigation was made to determine the effects on the aerodynamic characteristics of a 35 degree swept-wing airplane of applying area-suction boundary-layer control to the trailing-edge flaps. Flight tests of a similar airplane were then conducted to determine the effect of boundary-layer control in the handling qualities and operation of the airplane, particularly during landing. The wind-tunnel and flight tests indicated that area suction applied to the trailing-edge flaps produced significant increases in flap lift increment. Although the flap boundary-layer control reduced the stall speed only slightly, a reduction in minimum comfortable approach speed of about 12 knots was obtained.
NASA Technical Reports Server (NTRS)
Freeman, Hugh B.
1935-01-01
Tests were made in the N.A.C.A. 20-foot wind tunnel on: (1) a wing, of 6.5-foot span, 5.5-foot chord, and 30 percent maximum thickness, fitted with large end plates and (2) a 16-foot span 2.67-foot chord wing of 15 percent maximum thickness to determine the increase in lift obtainable by removing the boundary layer and the power required for the blower. The results of the tests on the stub wing appeared more favorable than previous small-scale tests and indicated that: (1) the suction method was considerably superior to the pressure method, (2) single slots were more effective than multiple slots (where the same pressure was applied to all slots), the slot efficiency increased rapidly for increasing slot widths up to 2 percent of the wing chord and remained practically constant for all larger widths tested, (3) suction pressure and power requirements were quite low (a computation for a light airplane showed that a lift coefficient of 3.0 could be obtained with a suction as low as 2.3 times the dynamic pressure and a power expenditure less than 3 percent of the rated engine power), and (4) the volume of air required to be drawn off was quite high (approximately 0.5 cubic feet per second per unit wing area for an airplane landing at 40 miles per hour with a lift coefficient of 3,0), indicating that considerable duct area must be provided in order to prevent flow losses inside the wing and insure uniform distribution of suction along the span. The results from the tests of the large-span wing were less favorable than those on the stub wing. The reasons for this were, probably: (1) the uneven distribution of suction along the span, (2) the flow losses inside the wing, (3) the small radius of curvature of the leading edge of the wing section, and (4) the low Reynolds Number of these tests, which was about one half that of the stub wing. The results showed a large increase in the maximum lift coefficient with an increase in Reynolds Number in the range of the tests. The results of drag tests showed that the profile drag of the wing was reduced and the L/D ratio was increased throughout the range of lift coefficients corresponding to take-off and climb but that the minimum drag was increased. The slot arrangement that is best for low drag is not the same, however, as that for maximum lift.
A computer program for the calculation of laminar and turbulent boundary layer flows
NASA Technical Reports Server (NTRS)
Dwyer, H. A.; Doss, E. D.; Goldman, A. L.
1972-01-01
The results are presented of a study to produce a computer program to calculate laminar and turbulent boundary layer flows. The program is capable of calculating the following types of flow: (1) incompressible or compressible, (2) two dimensional or axisymmetric, and (3) flows with significant transverse curvature. Also, the program can handle a large variety of boundary conditions, such as blowing or suction, arbitrary temperature distributions and arbitrary wall heat fluxes. The program has been specialized to the calculation of equilibrium air flows and all of the thermodynamic and transport properties used are for air. For the turbulent transport properties, the eddy viscosity approach has been used. Although the eddy viscosity models are semi-empirical, the model employed in the program has corrections for pressure gradients, suction and blowing and compressibility. The basic method of approach is to put the equations of motion into a finite difference form and then solve them by use of a digital computer. The program is written in FORTRAN 4 and requires small amounts of computer time on most scientific machines. For example, most laminar flows can be calculated in less than one minute of machine time, while turbulent flows usually require three or four minutes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rutqvist, J.; Ijiri, Y.; Yamamoto, H.
This paper presents the implementation of the Barcelona Basic Model (BBM) into the TOUGH-FLAC simulator analyzing the geomechanical behavior of unsaturated soils. We implemented the BBM into TOUGH-FLAC by (1) extending an existing FLAC{sup 3D} module for the Modified Cam-Clay (MCC) model in FLAC{sup 3D} and (2) adding computational routines for suction-dependent strain and net stress (i.e., total stress minus gas pressure) for unsaturated soils. We implemented a thermo-elasto-plastic version of the BBM, wherein the soil strength depends on both suction and temperature. The implementation of the BBM into TOUGH-FLAC was verified and tested against several published numerical model simulationsmore » and laboratory experiments involving the coupled thermal-hydrological-mechanical (THM) behavior of unsaturated soils. The simulation tests included modeling the mechanical behavior of bentonite-sand mixtures, which are being considered as back-fill and buffer materials for geological disposal of spent nuclear fuel. We also tested and demonstrated the use of the BBM and TOUGH-FLAC for a problem involving the coupled THM processes within a bentonite-backfilled nuclear waste emplacement tunnel. The simulation results indicated complex geomechanical behavior of the bentonite backfill, including a nonuniform distribution of buffer porosity and density that could not be captured in an alternative, simplified, linear-elastic swelling model. As a result of the work presented in this paper, TOUGH-FLAC with BBM is now fully operational and ready to be applied to problems associated with nuclear waste disposal in bentonite-backfilled tunnels, as well as other scientific and engineering problems related to the mechanical behavior of unsaturated soils.« less
A self-contained, automated methodology for optimal flow control validated for transition delay
NASA Technical Reports Server (NTRS)
Joslin, Ronald D.; Gunzburger, Max D.; Nicolaides, R. A.; Erlebacher, Gordon; Hussaini, M. Yousuff
1995-01-01
This paper describes a self-contained, automated methodology for flow control along with a validation of the methodology for the problem of boundary layer instability suppression. The objective of control is to match the stress vector along a portion of the boundary to a given vector; instability suppression is achieved by choosing the given vector to be that of a steady base flow, e.g., Blasius boundary layer. Control is effected through the injection or suction of fluid through a single orifice on the boundary. The present approach couples the time-dependent Navier-Stokes system with an adjoint Navier-Stokes system and optimality conditions from which optimal states, i.e., unsteady flow fields, and control, e.g., actuators, may be determined. The results demonstrate that instability suppression can be achieved without any a priori knowledge of the disturbance, which is significant because other control techniques have required some knowledge of the flow unsteadiness such as frequencies, instability type, etc.
Performance and scaling of a novel locomotor structure: adhesive capacity of climbing gobiid fishes.
Maie, Takashi; Schoenfuss, Heiko L; Blob, Richard W
2012-11-15
Many species of gobiid fishes adhere to surfaces using a sucker formed from fusion of the pelvic fins. Juveniles of many amphidromous species use this pelvic sucker to scale waterfalls during migrations to upstream habitats after an oceanic larval phase. However, adults may still use suckers to re-scale waterfalls if displaced. If attachment force is proportional to sucker area and if growth of the sucker is isometric, then increases in the forces that climbing fish must resist might outpace adhesive capacity, causing climbing performance to decline through ontogeny. To test for such trends, we measured pressure differentials and adhesive suction forces generated by the pelvic sucker across wide size ranges in six goby species, including climbing and non-climbing taxa. Suction was achieved via two distinct growth strategies: (1) small suckers with isometric (or negatively allometric) scaling among climbing gobies and (2) large suckers with positively allometric growth in non-climbing gobies. Species using the first strategy show a high baseline of adhesive capacity that may aid climbing performance throughout ontogeny, with pressure differentials and suction forces much greater than expected if adhesion were a passive function of sucker area. In contrast, large suckers possessed by non-climbing species may help compensate for reduced pressure differentials, thereby producing suction sufficient to support body weight. Climbing Sicyopterus species also use oral suckers during climbing waterfalls, and these exhibited scaling patterns similar to those for pelvic suckers. However, oral suction force was considerably lower than that for pelvic suckers, reducing the ability for these fish to attach to substrates by the oral sucker alone.
DuCanto, James; Serrano, Karen D; Thompson, Ryan J
2017-01-01
We present a novel airway simulation tool that recreates the dynamic challenges associated with emergency airways. The Suction-Assisted Laryngoscopy Assisted Decontamination (SALAD) simulation system trains providers to use suction to manage emesis and bleeding complicating intubation. We modified a standard difficult-airway mannequin head (Nasco, Ft. Atkinson, WI) with hardware-store equipment to enable simulation of vomiting or hemorrhage during intubation. A pre- and post-survey was used to assess the effectiveness of the SALAD simulator. We used a 1-5 Likert scale to assess confidence in managing the airway of a vomiting patient and comfort with suction techniques before and after the training exercise. Forty learners participated in the simulation, including emergency physicians, anesthesiologists, paramedics, respiratory therapists, and registered nurses. The average Likert score of confidence in managing the airway of a vomiting or hemorrhaging patient pre-session was 3.10±0.49, and post-session 4.13±0.22. The average score of self-perceived skill with suction techniques in the airway scenario pre-session was 3.30±0.43, and post-session 4.03±0.26. The average score for usefulness of the session was 4.68±0.15, and the score for realism of the simulator was 4.65±0.17. A training session with the SALAD simulator improved trainee's confidence in managing the airway of a vomiting or hemorrhaging patient. The SALAD simulation system recreates the dynamic challenges associated with emergency airways and holds promise as an airway training tool.
Danilla, Stefan; Fontbona, Montserrat; de Valdés, Victoria Diaz; Dagnino, Bruno; Sorolla, Juan Pablo; Israel, Guillermo; Searle, Susana; Norambuena, Hernán; Cabello, Rodrigo
2013-08-01
Suction-assisted lipectomy is one of the most common procedures performed in plastic surgery. To minimize blood loss and to obtain adequate analgesia, a liquid solution is infiltrated into the subcutaneous plane before suction. The objective of this study was to determine whether the use of lidocaine in the infiltration solution reduces postoperative pain. A prospective, randomized, double-masked, clinical trial was designed. Each side of patients' body zones to be treated with suction-assisted lipectomy was randomized to receive infiltration solution with or without lidocaine. Treatment allocation was performed using computer-generated random numbers in permuted blocks of eight. Pain was assessed using the visual analogue scale and registered 1, 6, 12, 18, and 24 hours after the procedure. The trial was stopped after a first interim analysis. The use of lidocaine in the dilute solution reduced pain by 0.5 point on the visual analogue scale (95 percent CI, 0.3 to 0.8; p<0.001). The effect was independent of the suctioned body zone (p=0.756), and lasted until 18 hours after surgery. Its analgesic effect was lost at the 24-hour postoperative control. Pain increased an average of 0.018 point on the visual analogue scale per hour (95 percent CI, 0.001 to 0.036; p=0.043). The use of lidocaine in the infiltration solution is effective in postoperative pain control until 18 hours after surgery. Nevertheless, its clinical effect is limited and clinically irrelevant, and therefore it is no longer used by the authors. Therapeutic, I.
López-López, C; Murillo-Pérez, M A; Morales-Sánchez, C; Torrente-Vela, S; Orejana-Martín, M; García-Iglesias, M; Cuenca-Solanas, M; Alted-López, E
2014-01-01
To assess pain response on patients with moderate to severe head injury before a common nursing procedure: tracheal suctioning. An observational longitudinal pilot study with consecutive sampling performed from September to December of 2012. Pain was assessed by a pain behavioral indicator scale 5 minutes before, meanwhile and 15 minutes after tracheal suctioning the days 1, 3 and 6 of their intensive care unit (ICU) stay, as well as a non-painful procedure: rubbing with gauze the forearm of the patient. Pseudo-analgesia and hemodynamic variables were also recorded. Descriptive analysis of the variables, inferential statistics with t-student and Anova with SPSS 17.0; statistical tests were considered significant if the critical level observed was less than 5% (P<.05). Pain was assessed on 27 patients. 82% suffered from severe head trauma and 18% moderate. The average pain value during nursing procedure day 1 was 3, 18±2.6, day 3: 2, 59±2 and day 6: 3, 94±2.3. There was a significant increase in mean pain while performing suctioning during the three days of assessment (P<.05); however no significant differences between the average pain value on the three days of the assessment (P>.05) were shown. Data for the painless procedure were significantly different on day 6 (P<.05) CONCLUSION: During tracheal suctioning in patients with head injury in the first 6 days in the ICU, objective mild-moderate pain according to ESCID scale has been detected. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Transition to turbulence in plane channel flows
NASA Technical Reports Server (NTRS)
Biringen, S.
1984-01-01
Results obtained from a numerical simulation of the final stages of transition to turbulence in plane channel flow are described. Three dimensional, incompressible Navier-Stokes equations are numerically integrated to obtain the time evolution of two and three dimensional finite amplitude disturbances. Computations are performed on CYBER-203 vector processor for a 32x51x32 grid. Results are presented for no-slip boundary conditions at the solid walls as well as for periodic suction blowing to simulate active control of transition by mass transfer. Solutions indicate that the method is capable of simulating the complex character of vorticity dynamics during the various stages of transition and final breakdown. In particular, evidence points to the formation of a lambda-shape vortex and the subsequent system of horseshoe vortices inclined to the main flow direction as the main elements of transition. Calculations involving periodic suction-blowing indicate that interference with a wave of suitable phase and amplitude reduces the disturbance growth rates.
Arbour, Jessica Hilary; López-Fernández, Hernán
2016-08-17
Adaptive radiations have been hypothesized to contribute broadly to the diversity of organisms. Models of adaptive radiation predict that ecological opportunity and ecological release, the availability of empty ecological niches and the response by adapting lineages to occupy them, respectively, drive patterns of phenotypic and lineage diversification. Adaptive radiations driven by 'ecological opportunity' are well established in island systems; it is less clear if ecological opportunity influences continent-wide diversification. We use Neotropical cichlid fishes to test if variation in rates of functional evolution is consistent with changing ecological opportunity. Across a functional morphological axis associated with ram-suction feeding traits, evolutionary rates declined through time as lineages diversified in South America. Evolutionary rates of ram-suction functional morphology also appear to have accelerated as cichlids colonized Central America and encountered renewed opportunity. Our results suggest that ecological opportunity may play an important role in shaping patterns of morphological diversity of even broadly distributed lineages like Neotropical cichlids. © 2016 The Author(s).
López-Fernández, Hernán
2016-01-01
Adaptive radiations have been hypothesized to contribute broadly to the diversity of organisms. Models of adaptive radiation predict that ecological opportunity and ecological release, the availability of empty ecological niches and the response by adapting lineages to occupy them, respectively, drive patterns of phenotypic and lineage diversification. Adaptive radiations driven by ‘ecological opportunity’ are well established in island systems; it is less clear if ecological opportunity influences continent-wide diversification. We use Neotropical cichlid fishes to test if variation in rates of functional evolution is consistent with changing ecological opportunity. Across a functional morphological axis associated with ram–suction feeding traits, evolutionary rates declined through time as lineages diversified in South America. Evolutionary rates of ram–suction functional morphology also appear to have accelerated as cichlids colonized Central America and encountered renewed opportunity. Our results suggest that ecological opportunity may play an important role in shaping patterns of morphological diversity of even broadly distributed lineages like Neotropical cichlids. PMID:27512144
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dougherty, Thomas J
A workpiece cutting apparatus includes a laser source, a first suction system, and a first finger configured to guide a workpiece as it moves past the laser source. The first finger includes a first end provided adjacent a point where a laser from the laser source cuts the workpiece, and the first end of the first finger includes an aperture in fluid communication with the first suction system.
Small, high pressure liquid hydrogen turbopump
NASA Technical Reports Server (NTRS)
Csomor, A.; Warren, D. J.
1980-01-01
A high pressure, low capacity, liquid hydrogen turbopump was designed, fabricated, and tested. The design configuration of the turbopump is summarized and the results of the analytical and test efforts are presented. Approaches used to pin point the cause of poor suction performance with the original design are described and performance data are included with an axial inlet design which results in excellent suction capability.
NASA Astrophysics Data System (ADS)
Bakar, Nor Ashikin Abu; Bachok, Norfifah; Arifin, Norihan Md.; Pop, Ioan
2018-06-01
The steady boundary layer flow over a stretching/shrinking cylinder with suction effect is numerically studied. Using a similarity transformations, the governing partial differential equations are transformed into a set of nonlinear differential equations and have been solved numerically using a bvp4c code in Matlab software. The nanofluid model used is taking into account the effects of Brownian motion and thermophoresis. The influences of the governing parameters namely the curvature parameter γ, mass suction parameter S, Brownian motion parameter Nb and thermophoresis parameter Nt on the flow, heat and mass transfers characteristics are presented graphically. The numerical results obtained for the skin friction coefficient, local Nusselt number and local Sherwood number are thoroughly determined and presented graphically for several values of the governing parameters. From our investigation, it is found that the non-unique (dual) solutions exist for a certain range of mass suction parameter. It is observed that as curvature parameter increases, the skin friction coefficient and heat transfer rate decrease, meanwhile the mass transfer rates increase. Moreover, the stability analysis showed that the first solution is linearly stable, while the second solution is linearly unstable.
Wei, Jinli; Zhang, Jiaxin; Fu, Deyuan
2016-06-01
Although breast abscess is a serious uncommon complication of mastitis with high morbidity rate, there is a lack of high-quality randomized trial to demonstrate the best treatments. We reported a novel way of applying negative suction drain through a mini periareolar incision. We retrospectively analyzed and compared the clinical characteristics of 62 patients with lactational breast abscess in our department from August 2012 to April 2015. Thirty-two patients went through traditional incision and drainage (Group A) and 30 patients were placed on negative suction drain through mini periareolar incision (Group B). There is no significant difference between the two groups in terms of age, white blood cell (WBC) count, size of the abscess cavity, and positive rate of Staphylococcus aureus (SA) or methicillin-resistant Staphylococcus aureus (MRSA). Patients in Group B had a shorter hospitalized stay (p = 0.003) and had a higher rate of continuation of breastfeeding (p < 0.005). Applying drain with negative suction pressure through a mini periareolar incision is an effective modality for treating lactational breast abscess and maintaining breastfeeding.
NASA Astrophysics Data System (ADS)
Murray, Mark; Shorter, Alex; Howle, Laurens; Johnson, Mark; Moore, Michael
2012-11-01
The improvement and miniaturization of sensing technologies has made bio-logging tags, utilized for the study of marine mammal behavior, more practical. These sophisticated sensing packages require a housing which protects the electronics from the environment and provides a means of attachment to the animal. The hydrodynamic forces on these housings can inadvertently remove the tag or adversely affect the behavior or energetics of the animal. A modification to the original design of a suction cup bio-logging tag housing was desired to minimize the adverse forces. In this work, hydrodynamic loading of two suction cup tag designs, original and modified designs, were analyzed using computational fluid dynamics (CFD) models and validated experimentally. Overall, the simulation and experimental results demonstrated that a tag housing that minimized geometric disruptions to the flow reduced drag forces, and that a tag housing with a small frontal cross-sectional area close to the attachment surface reduced lift forces. Preliminary results from experimental work with a common dolphin cadaver indicates that the suction cups used to attach the tags to the animal provide sufficient attachment force to resist failure at predicted drag and lift forces in 10 m/s flow.
Close-up view of 20 March 1976 tornadoes - Sinking cloud tops to suction vortices
NASA Technical Reports Server (NTRS)
Fujita, T. T.; Forbes, G. S.; Umenhofer, T. A.
1976-01-01
The article describes an airborne mission using a Learjet to secure direct data on a family of tornadoes spawned by a rotating thunderstorm in the Missouri-Illinois-Indiana area in March 1976 following an unusually warm February. Weakening of the tornado following increased cloud-scale vertical motion, predicted by a model constructed by Fujita (1972), was confirmed. The aircraft inspected overshooting cloud tops, examined subsidence (holes and depressions) in anvil tops it overflew, and surveyed footprints left by the tornadoes and tornado-blown litter on the ground traversed by the disturbances. Subsidence of cloud tops in advance of violent tornadoes below was confirmed. Isolated and multiple suction vortices left their characteristic ground marks; three scales of motion: tornado cyclone, tornado, and suction vortex, are evidenced by the ground truth.
Suction and Blowing Flow Control on Airfoil for Drag Reduction in Subsonic Flow
NASA Astrophysics Data System (ADS)
Baljit, S. S.; Saad, M. R.; Nasib, A. Z.; Sani, A.; Rahman, M. R. A.; Idris, A. C.
2017-10-01
Lift force is produced from a pressure difference between the pressures acting in upper and lower surfaces. Therefore, flow becomes detached from the surface of the airfoil at separation point and form vortices. These vortices affect the aerodynamic performance of the airfoil in term of lift and drag coefficient. Therefore, this study is investigating the effect of suction and jet blowing in boundary layer separation control on NACA 0012 airfoil in a subsonic wind tunnel. The experiment examined both methods at the position of 25% of the chord-length of the airfoil at Reynolds number 1.2 × 105. The findings show that suction and jet blowing affect the aerodynamic performance of NACA 0012 airfoil and can be an effective means for boundary layer separation control in subsonic flow.
Bernoulli Suction Effect on Soap Bubble Blowing?
NASA Astrophysics Data System (ADS)
Davidson, John; Ryu, Sangjin
2015-11-01
As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.
NASA Technical Reports Server (NTRS)
Campbell, Bryan A.; Applin, Zachary T.; Kemmerly, Guy T.; Coe, Paul L., Jr.; Owens, D. Bruce; Gile, Brenda E.; Parikh, Pradip G.; Smith, Don
1999-01-01
A wind tunnel investigation of a leading edge boundary layer control system was conducted on a High Speed Civil Transport (HSCT) configuration in the Langley 14- by 22-Foot Subsonic Tunnel. Data were obtained over a Mach number range of 0.08 to 0.27, with corresponding chord Reynolds numbers of 1.79 x 10(exp 6) to 5.76 x 10(exp 6). Variations in the amount of suction, as well as the size and location of the suction area, were tested with outboard leading edge flaps deflected 0 and 30 deg and trailing-edge flaps deflected 0 and 20 deg. The longitudinal and lateral aerodynamic data are presented without analysis. A complete tabulated data listing is also presented herein.
NASA Technical Reports Server (NTRS)
Lamar, J. E.; Gloss, B. B.
1975-01-01
Because the potential flow suction along the leading and side edges of a planform can be used to determine both leading- and side-edge vortex lift, the present investigation was undertaken to apply the vortex-lattice method to computing side-edge suction force for isolated or interacting planforms. Although there is a small effect of bound vortex sweep on the computation of the side-edge suction force, the results obtained for a number of different isolated planforms produced acceptable agreement with results obtained from a method employing continuous induced-velocity distributions. By using the method outlined, better agreement between theory and experiment was noted for a wing in the presence of a canard than was previously obtained.
Huang, Jianrong; Song, Leming; Xie, Donghua; Li, Monong; Deng, Xiaolin; Hu, Min; Peng, Zuofeng; Liu, Tairong; Du, Chuance; Yao, Lei; Liu, Shengfeng; Guo, Shulin; Zhong, Jiuqing
2016-12-08
Calculus pyonephrosis is difficult to manage. The aim of this study is to explore the value of a patented suctioning sheath assisted minimally invasive percutaneous nephrolithotomy (MPCNL) in the treatment of calculus pyonephrosis. One hundred and eighty two patients with calculus pyonephrosis were randomizely divided into observation group (n = 91) and control group (n = 91). The control group was treated with MPCNL traditionally using peel-away sheath while the observation group was treated with MPCNL using the patented suctioning sheath. All the patients in the observation group underwent one stage surgical treatment, 14 patients in the control group underwent first-stage surgery with the rest of the group underwent one stage surgery. The complication rate was 12.1% in the observation group, significantly lower than the rate in the control group which was 51.6%; One surgery stone clearance in the observation group was 96.7% while it was 73.6% in the control group; operative time in the observation group was (54.5 ± 14.5) min, compared to (70.2 ± 11.7) min in the control group; the bleeding amount in the observation group was (126.4 ± 47.2) ml, compared to (321.6 ± 82.5) ml in the control group; the hospitalization duration for the observation group was (6.4 ± 2.3) days, compared to (10.6 ± 3.7) days in the control group. Comparison of the above indicators, the observation group was better than the control group with significant difference (p < 0.001 each). Minimally invasive percutaneous nephrolithotomy with the aid of the patented suctioning sheath in the treatment of calculus pyonephrosis in one surgery is economic, practical, and warrants clinical promotion. This study was registered with Chinese Clinical Trial Registry on May 18, 2016 (retrospective registration) with a trial registration number of ChiCTR-IOR-16008490 .
Experimental analysis of the flow pattern of a pump turbine model in pump mode
NASA Astrophysics Data System (ADS)
Guggenberger, Mark; Senn, Florian; Jaberg, Helmut; Gehrer, Arno; Sallaberger, Manfred; Widmer, Christian
2016-11-01
Reversible pump turbines are the only means to store primary energy in an highly efficient way. Within a short time their operation can be switched between the different operational regimes thus enhancing the stabilization of the electric grid. These qualities in combination with the operation even at off-design conditions offer a high flexibility to the energy market. However, pump turbines pass through operational regimes where their behaviour becomes unstable. One of these effects occurs when the flowrate is decreased continuously down to a minimum. This point is the physical limitation of the pump operation and is very difficult to predict properly by numerical design without a model test. The purpose of the present study is to identify the fluid mechanical phenomena leading to the occurrence of instabilities of pump turbines in pump mode. A reduced scale model of a ANDRITZ pump turbine was installed on a 4-quadrant test rig for the experimental investigation of unstable conditions in pump mode. The performed measurements are based on the IEC60193-standard. Characteristic measurements at a single guide vane opening were carried out to get a detailed insight into the instabilities in pump mode. The interaction between runner and guide vane was analysed by Particle Image Velocimetry. Furthermore, high-speed visualizations of the suction side part load flow and the suction recirculation were performed. Like never before the flow pattern in the draft tube cone became visible with the help of a high-speed camera by intentionally caused cavitation effects which allow a qualitative view on the flow pattern in the draft tube cone. Suction recirculation is observed in form of single vortices separating from each runner blade and stretching into the draft tube against the main flow direction. To find an explanation for the flow phenomena responsible for the appearance of the unstable head curve also characteristic velocity distributions on the pressure side were combined with high-speed visualizations on the suction side of the pump turbine model. The results enhance the comprehension of the physical background leading to the instability and improve the numerical predictability of the instability in pump mode.
NASA Astrophysics Data System (ADS)
Bloem, E.; French, H. K.
2013-12-01
Monitoring contaminant transport at contaminated sites requires optimization of the configuration of a limited number of samplings points combined with heterogeneous flow and preferential flowpaths. Especially monitoring processes in the unsaturated zone is a major challenge due to the limited volume monitored by for example suction cups and their risk to clog in a highly active degradation zone. To make progress on soil contamination assessment and site characterization there is a strong need to integrate field-sale extensively instrumented tools, with non-invasive (geophysical) methods which provide spatially integrated measurements also in the unsaturated zone. Examples of sites that might require monitoring activities in the unsaturated zone are airports with winter frost where large quantities of de-icing chemicals are used each winter; salt and contaminant infiltration along roads; constructed infiltration systems for treatment of sewerage or landfill seepage. Electrical resistivity methods have proved to be useful as an indirect measurement of subsurface properties and processes at the field-scale. The non-uniqueness of the interpretation techniques can be reduced by constraining the inversion through the addition of independent geophysical measurements along the same profile. Or interpretation and understanding of geophysical images can be improved by the combination with classical measurements of soil physical properties, soil suction, contaminant concentration and temperatures. In our experiment, at the research field station at Gardermoen, Oslo airport, we applied a degradable de-icing chemical and an inactive tracer to the snow cover prior to snowmelt. To study the solute transport processes in the unsaturated zone time-lapse cross borehole electrical resistivity tomography (ERT) measurements were conducted at the same time as soil water samples were extracted at multiple depths with suction cups. Measurements of soil temperature, and soil tension were also carried out during the monitoring period. We present a selection of results from the snowmelt experiments and how the combination of measurement techniques can help interpret and understand the relative importance of the various contributions to the bulk electrical conductivity during snowmelt and solute transport.
A fundamental study of suction for Laminar Flow Control (LFC)
NASA Astrophysics Data System (ADS)
Watmuff, Jonathan H.
1992-10-01
This report covers the period forming the first year of the project. The aim is to experimentally investigate the effects of suction as a technique for Laminar Flow Control. Experiments are to be performed which require substantial modifications to be made to the experimental facility. Considerable effort has been spent developing new high performance constant temperature hot-wire anemometers for general purpose use in the Fluid Mechanics Laboratory. Twenty instruments have been delivered. An important feature of the facility is that it is totally automated under computer control. Unprecedently large quantities of data can be acquired and the results examined using the visualization tools developed specifically for studying the results of numerical simulations on graphics works stations. The experiment must be run for periods of up to a month at a time since the data is collected on a point-by-point basis. Several techniques were implemented to reduce the experimental run-time by a significant factor. Extra probes have been constructed and modifications have been made to the traverse hardware and to the real-time experimental code to enable multiple probes to be used. This will reduce the experimental run-time by the appropriate factor. Hot-wire calibration drift has been a frustrating problem owing to the large range of ambient temperatures experienced in the laboratory. The solution has been to repeat the calibrations at frequent intervals. However the calibration process has consumed up to 40 percent of the run-time. A new method of correcting the drift is very nearly finalized and when implemented it will also lead to a significant reduction in the experimental run-time.
A fundamental study of suction for Laminar Flow Control (LFC)
NASA Technical Reports Server (NTRS)
Watmuff, Jonathan H.
1992-01-01
This report covers the period forming the first year of the project. The aim is to experimentally investigate the effects of suction as a technique for Laminar Flow Control. Experiments are to be performed which require substantial modifications to be made to the experimental facility. Considerable effort has been spent developing new high performance constant temperature hot-wire anemometers for general purpose use in the Fluid Mechanics Laboratory. Twenty instruments have been delivered. An important feature of the facility is that it is totally automated under computer control. Unprecedently large quantities of data can be acquired and the results examined using the visualization tools developed specifically for studying the results of numerical simulations on graphics works stations. The experiment must be run for periods of up to a month at a time since the data is collected on a point-by-point basis. Several techniques were implemented to reduce the experimental run-time by a significant factor. Extra probes have been constructed and modifications have been made to the traverse hardware and to the real-time experimental code to enable multiple probes to be used. This will reduce the experimental run-time by the appropriate factor. Hot-wire calibration drift has been a frustrating problem owing to the large range of ambient temperatures experienced in the laboratory. The solution has been to repeat the calibrations at frequent intervals. However the calibration process has consumed up to 40 percent of the run-time. A new method of correcting the drift is very nearly finalized and when implemented it will also lead to a significant reduction in the experimental run-time.
NASA Astrophysics Data System (ADS)
Pearson, H. C.; Srinivasan, M.
2016-02-01
Documented changes in regional abundance and distribution of marine mammals may be driven by climate, ecosystem, and human-induced variations, operating synergistically or individually on different time scales. However, long-term but fine-scale data on animal ranging and foraging patterns are needed to fully understand the mechanism and magnitude of such changes and if/how top predators such as marine mammals are adapting. This is particularly important for dolphins, for which non-invasive, longer duration tags are needed to track their daily and weekly movement patterns in concert with changes in prey. As part of an ongoing study on dusky dolphins (Lagenorhynchus obscurus) in Kaikoura, New Zealand, we are developing a short-term, non-invasive suction-cup tagging method for collecting high resolution data on dolphin foraging and ranging behavior. This is an advancement in the field of animal telemetry as few published studies have tested non-invasive suction-cup tagging methods on small (< 2 m) delphinids, and even fewer report successful deployments. During austral summer 2013-14 and austral winter 2014, we spent 149 h over 31 d searching for and observing dusky dolphins. Of 71 tagging attempts made, 49% (n = 35) were "sticks" (i.e., the tag adhered to the dolphin). The longest tag attachment time was 357 min. Dive depths tended to increase throughout the day, reaching maximum daytime dive depths of c.a. 25 m. This is consistent with dolphin behavior off Kaikoura, as individuals feed mainly at night on mesopelagic organisms. Most (92%, n = 46) dolphins exhibited low-level responses to tagging, indicating this to be an appropriate species on which to continue tagging efforts. Successful trials will facilitate application of the system to other small delphinids. Tagging data collected can be integrated with climate and oceanographic data derived from satellite sensors and other monitoring programs to produce a comprehensive picture of dolphin behavioral ecology.
Optimal hydraulic design of new-type shaft tubular pumping system
NASA Astrophysics Data System (ADS)
Zhu, H. G.; Zhang, R. T.; Zhou, J. R.
2012-11-01
Based on the characteristics of large flow rate, low-head, short annual operation time and high reliability of city flood-control pumping stations, a new-type shaft tubular pumping system featuring shaft suction box, siphon-type discharge passage with vacuum breaker as cutoff device was put forward, which possesses such advantages as simpler structure, reliable cutoff and higher energy performance. According to the design parameters of a city flood control pumping station, a numerical computation model was set up including shaft-type suction box, siphon-type discharge passage, pump impeller and guide vanes. By using commercial CFD software Fluent, RNG κ-epsilon turbulence model was adopted to close the three-dimensional time-averaged incompressible N-S equations. After completing optimal hydraulic design of shaft-type suction box, and keeping the parameters of total length, maximum width and outlet section unchanged, siphon-type discharge passages of three hump locations and three hump heights were designed and numerical analysis on the 9 hydraulic design schemes of pumping system were proceeded. The computational results show that the changing of hump locations and hump heights directly affects the internal flow patterns of discharge passages and hydraulic performances of the system, and when hump is located 3.66D from the inlet section and hump height is about 0.65D (D is the diameter of pump impeller), the new-type shaft tubular pumping system achieves better energy performances. A pumping system model test of the optimal designed scheme was carried out. The result shows that the highest pumping system efficiency reaches 75.96%, and when at design head of 1.15m the flow rate and system efficiency were 0.304m3/s and 63.10%, respectively. Thus, the validity of optimal design method was verified by the model test, and a solid foundation was laid for the application and extension of the new-type shaft tubular pumping system.
The RiSE climbing robot: body and leg design
NASA Astrophysics Data System (ADS)
Saunders, A.; Goldman, D. I.; Full, R. J.; Buehler, M.
2006-05-01
The RiSE robot is a biologically inspired, six legged climbing robot, designed for general mobility in scansorial (vertical walls, horizontal ledges, ground level) environments. It exhibits ground reaction forces that are similar to animal climbers and does not rely on suction, magnets or other surface-dependent specializations to achieve adhesion and shear force. We describe RiSE's body and leg design as well as its electromechanical, communications and computational infrastructure. We review design iterations that enable RiSE to climb 90° carpeted, cork covered and (a growing range of) stucco surfaces in the quasi-static regime.
Keefe, Morgan S; Keefe, Michael A
2009-01-01
Reconstruction in the head and neck can be difficult owing to the size of the defect or characteristics of the tissue that needs to be replaced. Facial wounds or reconstruction sites can be subject to contamination, thereby risking infection of any implanted material even under ideal circumstances. Particular areas of concern are sites where minimizing the bacterial contamination prior to placing an implant is difficult (eg, the oral cavity and internal nose). Reconstruction involves the facial subcutaneous soft tissue and/or bone, and the ideal implant provides support and natural feel, as well as a low risk of infection. The biocompatibility of alloplastic implants depends on the tissue inertness of the implant and the porosity, allowing connective tissue ingrowth, which in turn decreases the susceptibility to infection. Scalafani et al demonstrated that alloplastic implants contaminated prior to fibrovascular ingrowth had a much higher incidence of infection and rejection. To examine the effectiveness of several techniques for infiltrating antibiotics into alloplastic implants of different porosity using 2 commonly used alloplastic implants, expanded polytetrafluoroethylene (e-PTFE, or GORE-TEX) and porous high-density polyethylene (Medpor). Using an in vitro bacterial growth inhibition model, we found that suction infiltration of the implant with antibiotics was the most effective technique, with a statistically significant advantage over other techniques used. The advantages of the suction impregnation were seen to be most effective using alloplasts with a smaller pore size (20-30 microm) (P < .001), but there was a statistically significant difference even with implants with a larger pore size (150-200 microm) (P < .001). Suction infiltration of antibiotics into porous implants seems to be the most effective method identified using an in vitro testing protocol. Further experiments will be needed to confirm the effectiveness in reducing the perioperative risk of infection in vivo.
Free Convection from a Semi-Infinite Vertical Plate with Discontinuous Blowing or Suction.
1981-03-01
SCHIESSR UNCLASSIFIED; EhEllllEllEE EE[E]hEEEIllIEllhlEEIl EEEEEIIIEEEEI EEEIIIIIIIIII EIIIEIIEEEEII EEEIIIIIIIIIIE LVEL NAVAL POSTGRADUATE SCHOOL Monterey...the unsteady free convective flow past a simi-infinite porous plate with constant suction were studied through mathematical analysis by Soundalgekar...boundary-layers and; therefore, will often indicate a preferred method of analytical solution. Although there are several possible mathematical techniques
Flow Control about an Airborne Laser Turret
1982-06-01
that houses the laser telescope• Afterbody f=airing and f•iselage boundary layer suction were employed with porous material added when necessary to...Thesis Advisor Chairman, D partment of Aeronautics Dean of Scienci arnd Engineering 3 ABSTRACT This thesis project is the latest in a series of...that houses the laser telescope. Afterbody fairing and fuselage boundary layer suction were employed with porous material added when necessary to
Human muscle sympathetic nerve activity and plasma noradrenaline kinetics in space
Ertl, Andrew C; Diedrich, André; Biaggioni, Italo; Levine, Benjamin D; Robertson, Rose Marie; Cox, James F; Zuckerman, Julie H; Pawelczyk, James A; Ray, Chester A; Buckey, Jay C; Lane, Lynda D; Shiavi, Richard; Gaffney, F Andrew; Costa, Fernando; Holt, Carol; Blomqvist, C Gunnar; Eckberg, Dwain L; Baisch, Friedhelm J; Robertson, David
2002-01-01
Astronauts returning from space have reduced red blood cell masses, hypovolaemia and orthostatic intolerance, marked by greater cardio–acceleration during standing than before spaceflight, and in some, orthostatic hypotension and presyncope. Adaptation of the sympathetic nervous system occurring during spaceflight may be responsible for these postflight alterations. We tested the hypotheses that exposure to microgravity reduces sympathetic neural outflow and impairs sympathetic neural responses to orthostatic stress. We measured heart rate, photoplethysmographic finger arterial pressure, peroneal nerve muscle sympathetic activity and plasma noradrenaline spillover and clearance, in male astronauts before, during (flight day 12 or 13) and after the 16 day Neurolab space shuttle mission. Measurements were made during supine rest and orthostatic stress, as simulated on Earth and in space by 7 min periods of 15 and 30 mmHg lower body suction. Mean (± s.e.m.) heart rates before lower body suction were similar pre–flight and in flight. Heart rate responses to −30 mmHg were greater in flight (from 56 ± 4 to 72 ± 4 beats min−1) than pre–flight (from 56 ± 4 at rest to 62 ± 4 beats min−1, P < 0.05). Noradrenaline spillover and clearance were increased from pre–flight levels during baseline periods and during lower body suction, both in flight (n = 3) and on post–flight days 1 or 2 (n = 5, P < 0.05). In–flight baseline sympathetic nerve activity was increased above pre–flight levels (by 10–33 %) in the same three subjects in whom noradrenaline spillover and clearance were increased. The sympathetic response to 30 mmHg lower body suction was at pre–flight levels or higher in each subject (35 pre–flight vs. 40 bursts min−1 in flight). No astronaut experienced presyncope during lower body suction in space (or during upright tilt following the Neurolab mission). We conclude that in space, baseline sympathetic neural outflow is increased moderately and sympathetic responses to lower body suction are exaggerated. Therefore, notwithstanding hypovolaemia, astronauts respond normally to simulated orthostatic stress and are able to maintain their arterial pressures at normal levels. PMID:11773339
Tracheal tube biofilm removal through a novel closed-suctioning system: an experimental study.
Aguilera Xiol, E; Li Bassi, G; Wyncoll, D; Ntoumenopoulos, G; Fernandez-Barat, L; Marti, J D; Comaru, T; De Rosa, F; Rigol, M; Rinaudo, M; Ferrer, M; Torres, A
2015-11-01
Tracheal tube biofilm develops during mechanical ventilation. We compared a novel closed-suctioning system vs standard closed-suctioning system in the prevention of tracheal tube biofilm. Eighteen pigs, on mechanical ventilation for 76 h, with P. aeruginosa pneumonia were randomized to be tracheally suctioned via the KIMVENT* closed-suctioning system (control group) or a novel closed-suctioning system (treatment group), designed to remove tracheal tube biofilm through saline jets and an inflatable balloon. Upon autopsy, two tracheal tube hemi-sections were dissected for confocal and scanning electron microscopy. Biofilm area, maximal and minimal thickness were computed. Biofilm stage was assessed. Sixteen animals were included in the final analysis. In the treatment and control group, the mean (sd) pulmonary burden was 3.34 (1.28) and 4.17 (1.09) log cfu gr(-1), respectively (P=0.18). Tracheal tube P. aeruginosa colonization was 5.6 (4.9-6.3) and 6.2 (5.6-6.9) cfu ml(-1) (median and interquartile range) in the treatment and control group, respectively (P=0.23). In the treatment group, median biofilm area was 3.65 (3.22-4.21) log10 μm2 compared with 4.49 (4.27-4.52) log10 μm2 in the control group (P=0.031). In the treatment and control groups, the maximal biofilm thickness was 48.3 (26.7-71.2) µm (median and interquartile range) and 88.8 (43.8-125.7) µm, respectively. The minimal thickness in the treatment and control group was 0.6 (0-4.0) µm and 23.7 (5.3-27.8) µm (P=0.040) (P=0.017). Earlier stages of biofilm development were found in the treatment group (P<0.001). The novel CSS reduces biofilm accumulation within the tracheal tube. A clinical trial is required to confirm these findings and the impact on major outcomes. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Human muscle sympathetic nerve activity and plasma noradrenaline kinetics in space
NASA Technical Reports Server (NTRS)
Ertl, Andrew C.; Diedrich, Andre; Biaggioni, Italo; Levine, Benjamin D.; Robertson, Rose Marie; Cox, James F.; Zuckerman, Julie H.; Pawelczyk, James A.; Ray, Chester A.; Buckey, Jay C Jr;
2002-01-01
Astronauts returning from space have reduced red blood cell masses, hypovolaemia and orthostatic intolerance, marked by greater cardio-acceleration during standing than before spaceflight, and in some, orthostatic hypotension and presyncope. Adaptation of the sympathetic nervous system occurring during spaceflight may be responsible for these postflight alterations. We tested the hypotheses that exposure to microgravity reduces sympathetic neural outflow and impairs sympathetic neural responses to orthostatic stress. We measured heart rate, photoplethysmographic finger arterial pressure, peroneal nerve muscle sympathetic activity and plasma noradrenaline spillover and clearance, in male astronauts before, during (flight day 12 or 13) and after the 16 day Neurolab space shuttle mission. Measurements were made during supine rest and orthostatic stress, as simulated on Earth and in space by 7 min periods of 15 and 30 mmHg lower body suction. Mean (+/- S.E.M.) heart rates before lower body suction were similar pre-flight and in flight. Heart rate responses to -30 mmHg were greater in flight (from 56 +/- 4 to 72 +/- 4 beats min(-1)) than pre-flight (from 56 +/- 4 at rest to 62 +/- 4 beats min(-1), P < 0.05). Noradrenaline spillover and clearance were increased from pre-flight levels during baseline periods and during lower body suction, both in flight (n = 3) and on post-flight days 1 or 2 (n = 5, P < 0.05). In-flight baseline sympathetic nerve activity was increased above pre-flight levels (by 10-33 %) in the same three subjects in whom noradrenaline spillover and clearance were increased. The sympathetic response to 30 mmHg lower body suction was at pre-flight levels or higher in each subject (35 pre-flight vs. 40 bursts min(-1) in flight). No astronaut experienced presyncope during lower body suction in space (or during upright tilt following the Neurolab mission). We conclude that in space, baseline sympathetic neural outflow is increased moderately and sympathetic responses to lower body suction are exaggerated. Therefore, notwithstanding hypovolaemia, astronauts respond normally to simulated orthostatic stress and are able to maintain their arterial pressures at normal levels.
Enhanced heat sink with geometry induced wall-jet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, Md. Mahamudul, E-mail: sohel0991@gmail.com; Tikadar, Amitav; Bari, Fazlul
Mini-channels embedded in solid matrix have already proven to be a very efficient way of electronic cooling. Traditional mini-channel heat sinks consist of single layer of parallel channels. Although mini-channel heat sink can achieve very high heat flux, its pumping requirement for circulating liquid through the channel increase very sharply as the flow velocity increases. The pumping requirements of the heat sink can be reduced by increasing its performance. In this paper a novel approach to increase the thermal performance of the mini-channel heat sink is proposed through geometry induced wall jet which is a passive technique. Geometric irregularities alongmore » the channel length causes abrupt pressure change between the channels which causes cross flow through the interconnections thus one channel faces suction and other channel jet action. This suction and jet action disrupts boundary layer causing enhanced heat transfer performance. A CFD model has been developed using commercially available software package FLUENT to evaluate the technique. A parametric study of the velocities and the effect of the position of the wall-jets have been performed. Significant reduction in thermal resistance has been observed for wall-jets, it is also observed that this reduction in thermal resistance is dependent on the position and shape of the wall jet.« less
Modeling of soil water retention from saturation to oven dryness
Rossi, Cinzia; Nimmo, John R.
1994-01-01
Most analytical formulas used to model moisture retention in unsaturated porous media have been developed for the wet range and are unsuitable for applications in which low water contents are important. We have developed two models that fit the entire range from saturation to oven dryness in a practical and physically realistic way with smooth, continuous functions that have few parameters. Both models incorporate a power law and a logarithmic dependence of water content on suction, differing in how these two components are combined. In one model, functions are added together (model “sum”); in the other they are joined smoothly together at a discrete point (model “junction”). Both models also incorporate recent developments that assure a continuous derivative and force the function to reach zero water content at a finite value of suction that corresponds to oven dryness. The models have been tested with seven sets of water retention data that each cover nearly the entire range. The three-parameter sum model fits all data well and is useful for extrapolation into the dry range when data for it are unavailable. The two-parameter junction model fits most data sets almost as well as the sum model and has the advantage of being analytically integrable for convenient use with capillary-bundle models to obtain the unsaturated hydraulic conductivity.
Effect of Velocity and Temperature Distribution at the Hole Exit on Film Cooling of Turbine Blades
NASA Technical Reports Server (NTRS)
Garg, V. K.; Gaugler, R. E.
1997-01-01
An existing three-dimensional Navier-Stokes code (Arnone et al, 1991), modified Turbine Branch, to include film cooling considerations (Garg and Gaugler, 1994), has been used to study the effect of coolant velocity and temperature distribution at the hole exit on the heat transfer coefficient on three film-cooled turbine blades, namely, the C3X vane, the VKI rotor, and the ACE rotor. Results are also compared with the experimental data for all the blades. Moreover, Mayle's transition criterion (1991), Forest's model for augmentation of leading edge heat transfer due to free-stream turbulence (1977), and Crawford's model for augmentation of eddy viscosity due to film cooling (Crawford et al, 1980) are used. Use of Mayle's and Forest's models is relevant only for the ACE rotor due to the absence of showerhead cooling on this rotor. It is found that, in some cases, the effect of distribution of coolant velocity and temperature at the hole exit can be as much as 60 percent on the heat transfer coefficient at the blade suction surface, and 50 percent at the pressure surface. Also, different effects are observed on the pressure and suction surface depending upon the blade as well as upon the hole shape, conical or cylindrical.
Goto, Tomoaki; Shiba, Yojiro; Shibagaki, Kazuhiro; Nakaya, Kazuhiro
2013-06-01
We examined gill morphology and ventilatory function in the carpet shark family Parascylliidae using 14 preserved specimens of Parascyllium ferrugineum, P. variolatum, P. collare and Cirrhoscyllium japonicum, and two live specimens of P. ferrugineum and P. variolatum. Morphological examinations revealed eight morphological characteristics related to the fifth gill, based on comparisons with other elasmobranchs, viz. large fifth gill slit without gill filaments, anatomical modifications in the fourth ceratobranchial cartilage and coraco-branchialis muscle, and the hypaxialis muscle associated with the fifth gill arch. Ventilation examinations using dyed seawater and prey items showed different water flows through the gill slits for respiration and prey-capture actions. For respiration, water sucked into the mouth was expelled equally through the first to fourth gill slits via a "double-pump" action, there being no involvement of the fifth gill slit. In prey-capture, however, water sucked into the mouth was discharged only via the widely opened fifth gill slit. This form of water flow is similar to that in other benthic suction-feeding sharks (e.g., Chiloscyllium plagiosum), except for the active water discharge by wide expansion and contraction of the fifth parabranchial cavity. The latter is dependent upon the morphological modifications of the fourth and fifth gill arches, derived phylogenetically as a mechanistic suction specialization in Parascylliidae.
Passino, Claudio; Cencetti, Simone; Spadacini, Giammario; Quintana, Robert; Parker, Daryl; Robergs, Robert; Appenzeller, Otto; Bernardi, Luciano
2007-09-01
To assess the effects of acute exposure to simulated high altitude on baroreflex control of mean cerebral blood flow velocity (MCFV). We compared beat-to-beat changes in RR interval, arterial blood pressure, mean MCFV (by transcranial Doppler velocimetry in the middle cerebral artery), end-tidal CO2, oxygen saturation and respiration in 19 healthy subjects at baseline (Albuquerque, 1779 m), after acute exposure to simulated high altitude in a hypobaric chamber (barometric pressure as at 5000 m) and during oxygen administration (to achieve 100% oxygen saturation) at the same barometric pressure (HOX). Baroreflex control on each signal was assessed by univariate and bivariate power spectral analysis performed on time series obtained during controlled (15 breaths/min) breathing, before and during baroreflex modulation induced by 0.1-Hz sinusoidal neck suction. At baseline, neck suction was able to induce a clear increase in low-frequency power in MCFV (P<0.001) as well as in RR and blood pressure. At high altitude, MCFV, as well as RR and blood pressure, was still able to respond to neck suction (all P<0.001), compared to controlled breathing alone, despite marked decreases in end-tidal CO2 and oxygen saturation at high altitude. A similar response was obtained at HOX. Phase delay analysis excluded a passive transmission of low-frequency oscillations from arterial pressure to cerebral circulation. During acute exposure to high altitude, cerebral blood flow is still modulated by the autonomic nervous system through the baroreflex, whose sensitivity is not affected by changes in CO2 and oxygen saturation levels.
Futatsugi, Toshimasa; Takahashi, Jun; Oba, Hiroki; Ikegami, Shota; Mogami, Yuji; Shibata, Syunichi; Ohji, Yoshihito; Tanikawa, Hirotaka; Kato, Hiroyuki
2017-07-01
A retrospective analysis. To evaluate the association between early postoperative dural sac cross-sectional area (DCSA) and radicular pain. The correlation between postoperative magnetic resonance imaging (MRI) findings and postoperative neurological symptoms after lumbar decompression surgery is controversial. This study included 115 patients who underwent lumbar decompression surgery followed by MRI within 7 days postoperatively. There were 46 patients with early postoperative radicular pain, regardless of whether the pain was mild or similar to that before surgery. The intervertebral level with the smallest DCSA was identified on MRI and compared preoperatively and postoperatively. Risk factors for postoperative radicular pain were determined using univariate and multivariate analyses. Subanalysis according to absence/presence of a residual suction drain also was performed. Multivariate regression analysis showed that smaller postoperative DCSA was significantly associated with early postoperative radicular pain (per -10 mm; odds ratio, 1.26). The best cutoff value for radicular pain was early postoperative DCSA of 67.7 mm. Even with a cutoff value of <70 mm, sensitivity and specificity are 74.3% and 75.0%, respectively. Early postoperative DCSA was significantly larger before suction drain removal than after (119.7±10.1 vs. 93.9±5.4 mm). Smaller DCSA in the early postoperative period was associated with radicular pain after lumbar decompression surgery. The best cutoff value for postoperative radicular pain was 67.7 mm. Absence of a suction drain at the time of early postoperative MRI was related to smaller DCSA.
Intraoperative loss of core biopsy clips: clinical implications.
Calhoun, Kristine; Giuliano, Armando; Brenner, R James
2008-03-01
The purpose of this study was to report the occurrence of intraoperative loss of metallic marking clips placed during image-guided biopsy and to hypothesize the likely mechanism of this clinical problem. From January 2003 through December 2004, patients presenting for preoperative mammographic localization and operative excision of biopsy site marking clips were identified. Age, method of image-guided biopsy, number of excised specimens, and tissue diagnosis were determined. Specimen radiographs were used to identify cases of suspected intraoperative clip loss. Clips absent on specimen radiographs and postoperative mammograms were defined as lost intraoperatively. Biopsy site marking clips, surgical clips, and suction device apertures were measured. In 78 surgical procedures performed during the study period, three (3.8%) of the patients experienced clip loss. Specimen radiographs confirmed the absence of clips in all submitted tissues. A median of four (range, three to five) separate biopsy specimens were excised among these three cases. A healing biopsy site from the stereotactic biopsy preceding the clip placement procedure was confirmed in all cases. Absence of the metallic clip was confirmed on postoperative mammograms. The apertures of two types of suction device were four and two times those of the biopsy clips. Intraoperative loss of metallic clips placed at the conclusion of image-guided breast biopsy is unusual but can occur during subsequent surgical excision. Repeated inability to locate the clip on specimen radiographs after accurate preoperative localization should raise the suspicion that the target clip has been lost, not missed, during surgery, likely because of inadvertent removal of the clip with the suction device.
Acetylcholine-induced current in perfused rat myoballs
1980-01-01
Spherical "myoballs" were grown under tissue culture conditions from striated muscle of neonatal rat thighs. The myoballs were examined electrophysiologically with a suction pipette which was used to pass current and perfuse internally. A microelectrode was used to record membrane potential. Experiments were performed with approximately symmetrical (intracellular and extracellular) sodium aspartate solutions. The resting potential, acetylcholine (ACh) reversal potential, and sodium channel reversal potential were all approximately 0 mV. ACh-induced currents were examined by use of both voltage jumps and voltage ramps in the presence of iontophoretically applied agonist. The voltage-jump relaxations had a single exponential time-course. The time constant, tau, was exponentially related to membrane potential, increasing e-fold for 81 mV hyperpolarization. The equilibrium current- voltage relationship was also approximately exponential, from -120 to +81 mV, increasing e-fold for 104 mV hyperpolarization. The data are consistent with a first-order gating process in which the channel opening rate constant is slightly voltage dependent. The instantaneous current-voltage relationship was sublinear in the hyperpolarizing direction. Several models are discussed which can account for the nonlinearity. Evidence is presented that the "selectivity filter" for the ACh channel is located near the intracellular membrane surface. PMID:7381423
Vijai, M N; Ravi, Parli R; Setlur, Rangaraj; Vardhan, Harsh
2016-05-01
Oropharyngeal colonisation followed by aspiration of contaminated secretions is the major cause for ventilator-associated pneumonia (VAP). Pooled secretions present in the sub-glottic area above inflated endotracheal tube cuff may be aspirated into the lower airways. It was hypothesised that intermittent suctioning of sub-glottic secretions would prevent VAP. Group I (n = 50) patients were intubated with HiLo Evac™ endotracheal (ET) tube with facility for sub-glottic suctioning, and Group II (n = 50) patients were intubated with HiLo Contour™ ET tube without such facility. In the Group I, sub-glottic suctioning was performed every 2 h. Incidence of VAP, mean ventilator days, Intensive Care Unit (ICU) stay and mortality were compared. Qualitative variables were reported as percentages and were compared by Chi-square test or unpaired two-tailed, Fisher's exact test, as appropriate, to analyse the significance of difference between the two groups. The two groups were similar with respect to demographic characteristics. VAP was seen in 6% of patients in Group I and 22% of patients in Group II (P = 0.021). Both early- and late-onset VAPs were significantly reduced in Group I. Both ventilator days (8.0 vs. 6.45; P = 0.001) and ICU stay (8.33 vs. 6.33; P = 0.001) on the day of onset of VAP were significantly more in the Group I. Total ventilator days were significantly less (6.52 vs. 8.32; P = 0.006) with lower incidence of mortality (36% vs. 48%; P = 0.224) in the Group I. Intermittent sub-glottic suctioning reduces the incidence of VAP including late-onset VAP.
'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans
NASA Technical Reports Server (NTRS)
Taylor, J. A.; Halliwill, J. R.; Brown, T. E.; Hayano, J.; Eckberg, D. L.
1995-01-01
1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.
Limb suction evoked during arterial occlusion causes systemic sympathetic activity in humans
Cui, Jian; Blaha, Cheryl; Herr, Michael D.; Drew, Rachel C.; Muller, Matthew D.
2015-01-01
Venous saline infusions in an arterially occluded forearm evokes reflex increases in muscle sympathetic nerve activity (MSNA) and blood pressure (BP). We hypothesized that the application of suction to the human limbs would activate this venous distension reflex and raise sympathetic outflow. We placed airtight pressure tanks and applied 100 mmHg negative pressure to an arterially occluded limb (occlusion and suction, O&S) to induce tissue deformation without fluid translocation. BP, heart rate (HR), and MSNA were assessed in 19 healthy subjects during 2 min of arm or leg O&S. Occlusion without suction served as a control. During a separate visit, saline (5% forearm volume) was infused into veins of the arterially occluded arm (n = 13). The O&S increased limb circumference, MSNA burst rate (arm: Δ6.7 ± 0.7; leg: Δ6.8 ± 0.7 bursts/min), and total activity (arm: Δ199 ± 14; leg: Δ172 ± 22 units/min) and BP (arm: Δ4.3 ± 0.3; leg: Δ9.4 ± 1.4 mmHg) from the baseline. The MSNA and BP responses during arm O&S correlated with those during leg O&S. Occlusion alone had no effect on MSNA and BP. MSNA (r = 0.607) responses during arm O&S correlated with those evoked by the saline infusion into the arm. These correlations suggest that sympathetic activation during limb O&S is likely, at least partially, to be evoked via the venous distension reflex. These data suggest that suction of an occluded limb evokes sympathetic activation and that the limb venous distension reflex exists in arms and legs of normal humans. PMID:26136530
Skin Friction Reduction by Micro-Blowing Technique
NASA Technical Reports Server (NTRS)
Hwang, Danny P. (Inventor)
1998-01-01
A system and method for reducing skin friction of an object in relative motion to a fluid. A skin forming a boundary between the object and the fluid, the skin having holes through which micro-blowing of air is blown and a transmitting mechanism for transmitting air through the skin. The skin has an inner layer and an outer layer. the inner layer being a low permeable porous sheet, the outer layer being a plate having high aspect ratio high porosity. and small holes. The system may further include a suction apparatus for suctioning air from the outer layer. The method includes the steps of transmitting air through the inner layer and passing the air transmitted through the inner layer to the outer layer. The method may further include the step of bleeding air off the outer layer using the suction apparatus.
Application of Laminar Flow Control Technology to Long-Range Transport Design
NASA Technical Reports Server (NTRS)
Gratzer, L. B.; George-Falvy, D.
1978-01-01
The impact of laminar flow control (LFC) technology on aircraft structural design concepts and systems was discussed and the corresponding benefits were shown in terms of performance and fuel economy. Specific topics discussed include: (1) recent advances in laminar boundary layer development and stability analysis techniques in terms of suction requirements and wing suction surface design; (2) validation of theory and realistic simulation of disturbances and off-design conditions by wind tunnel testing; (3) compatibility of aerodynamic design of airfoils and wings with LFC requirements; (4) structural alternatives involving advanced alloys or composites in combinations made possible by advanced materials processing and manufacturing techniques; (5) addition of suction compressor and drive units and their location on the aircraft; and (6) problems associated with operation of LFC aircraft, including accumulation of insects at low altitudes and environmental considerations.
Attraction to mammals of male mosquitoes with special reference to Aedes diantaeus in Sweden.
Jaenson, T G
1985-06-01
During investigations in central Sweden on the ecology of mosquito vectors of Ockelbo disease, large numbers of Aedes diantaeus males and lesser numbers of Ae. communis, Ae. excrucians and Ae. intrudens males were captured in animal-baited (rabbit, guinea pig, hen, dove, unbaited control) suction- and net-traps. In the five suction-traps, 57% of the diantaeus captured (N = 1,896) were males. Although the guinea pig-baited suction-trap captured the highest mean number of diantaeus males, data showed that these males, like the females, were mainly attracted to the largest mammal, i.e., the rabbit. These males assembled in the vicinity of the rabbit presumably to intercept females coming to feed. The net-trap data showed that orientation by the males to the rabbit presumably involved olfactory cues emanating from the mammal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasmani, Ruhaila Md; Bhuvaneswari, M.; Sivasankaran, S.
2015-10-22
An analysis is presented to find the effects of thermal radiation and heat generation/absorption on convection heat transfer of nanofluid past a wedge in the presence of wall suction. The governing partial differential equations are transformed into a system of ordinary differential equations using similarity transformation. The resulting system is solved numerically using a fourth-order Runge–Kutta method with shooting technique. Numerical computations are carried out for different values of dimensionless parameters to predict the effects of wedge angle, thermophoresis, Brownian motion, heat generation/absorption, thermal radiation and suction. It is found that the temperature increases significantly when the value of themore » heat generation/absorption parameter increases. But the opposite observation is found for the effect of thermal radiation.« less
What do foraging wasps optimize in a variable environment, energy investment or body temperature?
Kovac, Helmut; Stabentheiner, Anton; Brodschneider, Robert
2015-11-01
Vespine wasps (Vespula sp.) are endowed with a pronounced ability of endothermic heat production. To show how they balance energetics and thermoregulation under variable environmental conditions, we measured the body temperature and respiration of sucrose foragers (1.5 M, unlimited flow) under variable ambient temperature (T a = 20-35 °C) and solar radiation (20-570 W m(-2)). Results revealed a graduated balancing of metabolic efforts with thermoregulatory needs. The thoracic temperature in the shade depended on ambient temperature, increasing from ~37 to 39 °C. However, wasps used solar heat gain to regulate their thorax temperature at a rather high level at low T a (mean T thorax ~ 39 °C). Only at high T a they used solar heat to reduce their metabolic rate remarkably. A high body temperature accelerated the suction speed and shortened foraging time. As the costs of foraging strongly depended on duration, the efficiency could be significantly increased with a high body temperature. Heat gain from solar radiation enabled the wasps to enhance foraging efficiency at high ambient temperature (T a = 30 °C) by up to 63 %. The well-balanced change of economic strategies in response to environmental conditions minimized costs of foraging and optimized energetic efficiency.
Spore collection and elimination apparatus and method
Czajkowski, Carl [South Jamesport, NY; Warren, Barbara Panessa [Port Jefferson, NY
2007-04-03
The present invention is for a spore collection apparatus and its method of use. The portable spore collection apparatus includes a suction source, a nebulizer, an ionization chamber and a filter canister. The suction source collects the spores from a surface. The spores are activated by heating whereby spore dormancy is broken. Moisture is then applied to the spores to begin germination. The spores are then exposed to alpha particles causing extinction.
NASA Technical Reports Server (NTRS)
Fisher, David F.; Banks, Daniel W.; Richwine, David M.
1990-01-01
Pressure distributions measured on the forebody and the leading-edge extensions (LEX's) of the NASA F-18 high alpha research vehicle (HARV) were reported at 10 and 50 degree angles of attack and at Mach 0.20 to 0.60. The results were correlated with HARV flow visualization and 6-percent scale F-18 wind-tunnel-model test results. The general trend in the data from the forebody was for the maximum suction pressure peaks to first appear at an angle of attack (alpha) of approximately 19 degrees and increase in magnitude with angle of attack. The LEX pressure distribution general trend was the inward progression and increase in magnitude of the maximum suction peaks up to vortex core breakdown and then the decrease and general flattening of the pressure distribution beyond that. No significant effect of Mach number was noted for the forebody results. However, a substantial compressibility effect on the LEX's resulted in a significant reduction in vortex-induced suction pressure as Mach number increased. The forebody primary and the LEX secondary vortex separation lines, from surface flow visualization, correlated well with the end of pressure recovery, leeward and windward, respectively, of maximum suction pressure peaks. The flight to wind-tunnel correlations were generally good with some exceptions.
Nanocrystallization in Cu-Zr-Al-Sm Bulk Metallic Glasses
NASA Astrophysics Data System (ADS)
Sikan, Fatih; Yasar, Bengisu; Kalay, Ilkay
2018-04-01
The effect of rare-earth element (Sm) microalloying on the thermal stability and crystallization kinetics of melt-spun ribbons and suction-cast rods of Zr48Cu38.4Al9.6Sm4 alloy were investigated using differential scanning calorimetry (DSC), X-ray diffraction (XRD), transmission electron microscopy (TEM), and atom probe tomography (APT). The XRD results of constant heating rate annealing indicated that amorphous Zr48Cu38.4Al9.6Sm4 melt-spun ribbons devitrifies into Cu2Sm at 673 K (400 °C). The sequence continues with the precipitation of Cu10Zr7 and then these two phases coexist. XRD and TEM studies on 1 mm diameter as suction-cast rods indicated the precipitation of 30-nm-mean size Cu2Sm crystals during solidification. TEM investigation of the isothermal crystallization sequence of melt-spun ribbons and 1-mm-diameter suction-cast rods revealed the precipitation of Cu2Sm nanocrystals at the onset of crystallization and the restriction of the growth of these nanocrystals up to 10 nm diameter with further annealing. APT analysis of 1-mm-diameter suction-cast rods showed that the limited growth of Cu2Sm nanocrystals is due to sluggish diffusion of Sm and Al-Zr pile up at the interface.
Flow Characteristics and Robustness of an Inclined Quad-vortex Range Hood
CHEN, Jia-Kun; HUANG, Rong Fung
2014-01-01
A novel design of range hood, which was termed the inclined quad-vortex (IQV) range hood, was examined for its flow and containment leakage characteristics under the influence of a plate sweeping across the hood face. A flow visualization technique was used to unveil the flow behavior. Three characteristic flow modes were observed: convex, straight, and concave modes. A tracer gas detection method using sulfur hexafluoride (SF6) was employed to measure the containment leakage levels. The results were compared with the test data reported previously in the literature for a conventional range hood and an inclined air curtain (IAC) range hood. The leakage SF6 concentration of the IQV range hood under the influence of the plate sweeping was 0.039 ppm at a suction flow rate of 9.4 m3/min. The leakage concentration of the conventional range hood was 0.768 ppm at a suction flow rate of 15.0 m3/min. For the IAC range hood, the leakage concentration was 0.326 ppm at a suction flow rate of 10.9 m3/min. The IQV range hood presented a significantly lower leakage level at a smaller suction flow rate than the conventional and IAC range hoods due to its aerodynamic design for flow behavior. PMID:24583513
Investigation of transonic flow over segmented slotted wind tunnel wall with mass transfer
NASA Technical Reports Server (NTRS)
Bhat, M. K.; Vakili, A. D.; Wu, J. M.
1990-01-01
The flowfield on a segmented multi-slotted wind tunnel wall was studied at transonic speeds by measurements in and near the wall layer using five port cone probes. The slotted wall flowfield was observed to be three-dimensional in nature for a relatively significant distance above the slot. The boundary layer characteristics measured on the single slotted wall were found to be very sensitive to the applied suction through the slot. The perturbation in the velocity components generated due to the flow through the slot decay rapidly in the transverse direction. A vortex-like flow existed on the single slotted wall for natural ventilation but diminished with increased suction flow rate. For flow on a segmented multi-slotted wall, the normal velocity component changes were found to be maximum for measurement points located between the segmented slots atop the active chamber. The lateral influence due to applied suction and blowing, through a compartment, exceeded only slightly that in the downstream direction. Limited upstream influence was observed. Influence coefficients were determined from the data in the least-square sense for blowing and suction applied through one and two compartments. This was found to be an adequate determination of the influence coefficients for the range of mass flows considered.