Sample records for time excellent quantitative

  1. A dynamic regression analysis tool for quantitative assessment of bacterial growth written in Python.

    PubMed

    Hoeflinger, Jennifer L; Hoeflinger, Daniel E; Miller, Michael J

    2017-01-01

    Herein, an open-source method to generate quantitative bacterial growth data from high-throughput microplate assays is described. The bacterial lag time, maximum specific growth rate, doubling time and delta OD are reported. Our method was validated by carbohydrate utilization of lactobacilli, and visual inspection revealed 94% of regressions were deemed excellent. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. An Alu-based, MGB Eclipse real-time PCR method for quantitation of human DNA in forensic samples.

    PubMed

    Nicklas, Janice A; Buel, Eric

    2005-09-01

    The forensic community needs quick, reliable methods to quantitate human DNA in crime scene samples to replace the laborious and imprecise slot blot method. A real-time PCR based method has the possibility of allowing development of a faster and more quantitative assay. Alu sequences are primate-specific and are found in many copies in the human genome, making these sequences an excellent target or marker for human DNA. This paper describes the development of a real-time Alu sequence-based assay using MGB Eclipse primers and probes. The advantages of this assay are simplicity, speed, less hands-on-time and automated quantitation, as well as a large dynamic range (128 ng/microL to 0.5 pg/microL).

  3. Real-Time Intracellular Measurements of ROS and RNS in Living Cells with Single Core-Shell Nanowire Electrodes.

    PubMed

    Zhang, Xin-Wei; Qiu, Quan-Fa; Jiang, Hong; Zhang, Fu-Li; Liu, Yan-Lin; Amatore, Christian; Huang, Wei-Hua

    2017-10-09

    Nanoelectrodes allow precise and quantitative measurements of important biological processes at the single living-cell level in real time. Cylindrical nanowire electrodes (NWEs) required for intracellular measurements create a great challenge for achieving excellent electrochemical and mechanical performances. Herein, we present a facile and robust solution to this problem based on a unique SiC-core-shell design to produce cylindrical NWEs with superior mechanical toughness provided by the SiC nano-core and an excellent electrochemical performance provided by the ultrathin carbon shell that can be used as such or platinized. The use of such NWEs for biological applications is illustrated by the first quantitative measurements of ROS/RNS in individual phagolysosomes of living macrophages. As the shell material can be varied to meet any specific detection purpose, this work opens up new opportunities to monitor quantitatively biological functions occurring inside cells and their organelles. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. The Butterfly Effect for Physics Laboratories

    ERIC Educational Resources Information Center

    Claycomb, James R.; Valentine, John H.

    2015-01-01

    A low-cost chaos dynamics lab is developed for quantitative demonstration of the butterfly effect using a magnetic pendulum. Chaotic motion is explored by recording magnetic time series. Students analyze the data in Excel® to investigate the butterfly effect as well as the reconstruction of the strange attractor using time delay plots. The lab…

  5. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    PubMed

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients <10 vs. >10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  6. Performance evaluation of the Aptima® HCV Quant Dx assay for hepatitis C virus (HCV) RNA detection and quantification in comparison to the Abbott RealTime HCV assay.

    PubMed

    Garbuglia, Anna Rosa; Bibbò, Angela; Sciamanna, Roberta; Pisciotta, Marina; Capobianchi, Maria Rosaria

    2017-07-01

    The Aptima HCV Quant Dx assay (Aptima) is a real-time transcription-mediated amplification assay CE-approved for the diagnosis and monitoring of hepatitis C virus (HCV) infection. Aptima's analytical performance was compared to the Abbott RealTime HCV assay (RealTime) in a clinical routine setting. Overall 295 clinical plasma samples (117 prospective/fresh; 178 retrospective/frozen) from HCV-infected patients were tested in Aptima and RealTime to determine concordance on qualitative and quantitative results. Linearity and precision at low viral loads (VLs; 0.8-3.3LogIU/mL) was tested using dilutions of the 5th WHO standard, in 10 and 20 replicates in the two assays, respectively. The ability to measure different HCV genotypes and accuracy were analyzed using the Seracare EQA panel. Inter-assay agreement for qualitative results (prospective samples) was 88% (kappa=0.78). For the 127 samples with quantitative results in both assays, Aptima yielded on average slightly higher values (by 0.24LogIU/mL; Bland-Altman method) than RealTime. Concordance between assay results was excellent (R=0.98). At low VLs (0.8-3.3LogIU/mL), Aptima demonstrated good linearity and precision, similar to RealTime. Aptima detected and accurately quantified all main HCV genotypes. Aptima demonstrated excellent precision, linearity, and accuracy in all genotypes tested. Good concordance was observed between Aptima and RealTime assays in clinical samples. The performance of the Aptima assay, on the fully automated Panther platform, makes it an excellent candidate for the detection and monitoring of HCV RNA in plasma and serum samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Quantitative verification of ab initio self-consistent laser theory.

    PubMed

    Ge, Li; Tandy, Robert J; Stone, A D; Türeci, Hakan E

    2008-10-13

    We generalize and test the recent "ab initio" self-consistent (AISC) time-independent semiclassical laser theory. This self-consistent formalism generates all the stationary lasing properties in the multimode regime (frequencies, thresholds, internal and external fields, output power and emission pattern) from simple inputs: the dielectric function of the passive cavity, the atomic transition frequency, and the transverse relaxation time of the lasing transition.We find that the theory gives excellent quantitative agreement with full time-dependent simulations of the Maxwell-Bloch equations after it has been generalized to drop the slowly-varying envelope approximation. The theory is infinite order in the non-linear hole-burning interaction; the widely used third order approximation is shown to fail badly.

  8. Real-time quantitative PCR of Staphylococcus aureus and application in restaurant meals.

    PubMed

    Berrada, H; Soriano, J M; Mañes, J; Picó, Y

    2006-01-01

    Staphylococcus aureus is considered the second most common pathogen to cause outbreaks of food poisoning, exceeded only by Campylobacter. Consumption of foods containing this microorganism is often identified as the cause of illness. In this study, a rapid, reliable, and sensitive real-time quantitative PCR was developed and compared with conventional culture methods. Real-time quantitative PCR was carried out by purifying DNA extracts of S. aureus with a Staphylococcus sample preparation kit and quantifying it in the LightCycler system with hybridization probes. The assay was linear from a range of 10 to 10(6) S. aureus cells (r2 > 0.997). The PCR reaction presented an efficiency of >85%. Accuracy of the PCR-based assay, expressed as percent bias, was around 13%, and the precision, expressed as a percentage of the coefficient of variation, was 7 to 10%. Intraday and interday variability were studied at 10(2) CFU/g and was 12 and 14%, respectively. The proposed method was applied to the analysis of 77 samples of restaurant meals in Valencia (Spain). In 11.6% of samples S. aureus was detected by real-time quantitative PCR, as well as by the conventional microbiological method. An excellent correspondence between real-time quantitative PCR and microbiological numbers (CFU/g) was observed with deviations of < 28%.

  9. Excellence in the Knowledge-Based Economy: From Scientific to Research Excellence

    ERIC Educational Resources Information Center

    Sørensen, Mads P.; Bloch, Carter; Young, Mitchell

    2016-01-01

    In 2013, the European Union (EU) unveiled its new "Composite Indicator for Scientific and Technological Research Excellence." This is not an isolated occurrence; policy-based interest in excellence is growing all over the world. The heightened focus on excellence and, in particular, attempts to define it through quantitative indicators…

  10. Recording an Excel(®) Macro to Specify Date Ranges for Clinical Data.

    PubMed

    Deochand, Neil; Costello, Mack S; Fuqua, R Wayne

    2016-09-01

    The individuals served by behavior analysts are often funded by Medicaid, insurance companies, or private pay. The first two options usually require progress notes detailing graphically and quantitatively the behavioral outcomes. These progress notes usually come in the form of a written account of milestones achieved or barriers faced, graphical displays of behavioral data, and summary tables. The graphical displays are monthly, quarterly, and annual reports for the individuals that they serve. Microsoft Excel® is one of the most accessible tools by which to accomplish this task; however, presenting the required date ranges can be a time-consuming task. A task analysis is outlined to automate this process and reduce the time taken to accomplish indirect service hours to the clients served.

  11. Teaching Fundamental Skills in Microsoft Excel to First-Year Students in Quantitative Analysis

    ERIC Educational Resources Information Center

    Rubin, Samuel J.; Abrams, Binyomin

    2015-01-01

    Despite their technological savvy, most students entering university lack the necessary computer skills to succeed in a quantitative analysis course, in which they are often expected to input, analyze, and plot results of experiments without any previous formal education in Microsoft Excel or similar programs. This lack of formal education results…

  12. Addressing fluorogenic real-time qPCR inhibition using the novel custom Excel file system 'FocusField2-6GallupqPCRSet-upTool-001' to attain consistently high fidelity qPCR reactions

    PubMed Central

    Ackermann, Mark R.

    2006-01-01

    The purpose of this manuscript is to discuss fluorogenic real-time quantitative polymerase chain reaction (qPCR) inhibition and to introduce/define a novel Microsoft Excel-based file system which provides a way to detect and avoid inhibition, and enables investigators to consistently design dynamically-sound, truly LOG-linear qPCR reactions very quickly. The qPCR problems this invention solves are universal to all qPCR reactions, and it performs all necessary qPCR set-up calculations in about 52 seconds (using a pentium 4 processor) for up to seven qPCR targets and seventy-two samples at a time – calculations that commonly take capable investigators days to finish. We have named this custom Excel-based file system "FocusField2-6GallupqPCRSet-upTool-001" (FF2-6-001 qPCR set-up tool), and are in the process of transforming it into professional qPCR set-up software to be made available in 2007. The current prototype is already fully functional. PMID:17033699

  13. A novel multi-walled carbon nanotube-based antibody conjugate for quantitative and semi-quantitative lateral flow assays.

    PubMed

    Sun, Wenjuan; Hu, Xiaolong; Liu, Jia; Zhang, Yurong; Lu, Jianzhong; Zeng, Libo

    2017-10-01

    In this study, the multi-walled carbon nanotubes (MWCNTs) were applied in lateral flow strips (LFS) for semi-quantitative and quantitative assays. Firstly, the solubility of MWCNTs was improved using various surfactants to enhance their biocompatibility for practical application. The dispersed MWCNTs were conjugated with the methamphetamine (MET) antibody in a non-covalent manner and then manufactured into the LFS for the quantitative detection of MET. The MWCNTs-based lateral flow assay (MWCNTs-LFA) exhibited an excellent linear relationship between the values of test line and MET when its concentration ranges from 62.5 to 1500 ng/mL. The sensitivity of the LFS was evaluated by conjugating MWCNTs with HCG antibody and the MWCNTs conjugated method is 10 times more sensitive than the one conjugated with classical colloidal gold nanoparticles. Taken together, our data demonstrate that MWCNTs-LFA is a more sensitive and reliable assay for semi-quantitative and quantitative detection which can be used in forensic analysis.

  14. Book Review

    NASA Astrophysics Data System (ADS)

    Clevers, Jan G. P. W.

    2018-05-01

    This book provides a comprehensive and timely overview on all aspects of hyperspectral remote sensing combined with various applications. As such, it is an excellent book of reference for both students and professionals active in the field of optical remote sensing. It deals with all aspects of retrieving quantitative information on biophysical properties of the Earth's surface, the data corrections needed and the range of analysis approaches available.

  15. Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures

    NASA Astrophysics Data System (ADS)

    Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.

    2018-03-01

    Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.

  16. Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures

    NASA Astrophysics Data System (ADS)

    Boes, Kelsey S.; Roberts, Michael S.; Vinueza, Nelson R.

    2017-12-01

    Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. [Figure not available: see fulltext.

  17. Rapid Quadrupole-Time-of-Flight Mass Spectrometry Method Quantifies Oxygen-Rich Lignin Compound in Complex Mixtures.

    PubMed

    Boes, Kelsey S; Roberts, Michael S; Vinueza, Nelson R

    2018-03-01

    Complex mixture analysis is a costly and time-consuming task facing researchers with foci as varied as food science and fuel analysis. When faced with the task of quantifying oxygen-rich bio-oil molecules in a complex diesel mixture, we asked whether complex mixtures could be qualitatively and quantitatively analyzed on a single mass spectrometer with mid-range resolving power without the use of lengthy separations. To answer this question, we developed and evaluated a quantitation method that eliminated chromatography steps and expanded the use of quadrupole-time-of-flight mass spectrometry from primarily qualitative to quantitative as well. To account for mixture complexity, the method employed an ionization dopant, targeted tandem mass spectrometry, and an internal standard. This combination of three techniques achieved reliable quantitation of oxygen-rich eugenol in diesel from 300 to 2500 ng/mL with sufficient linearity (R 2 = 0.97 ± 0.01) and excellent accuracy (percent error = 0% ± 5). To understand the limitations of the method, it was compared to quantitation attained on a triple quadrupole mass spectrometer, the gold standard for quantitation. The triple quadrupole quantified eugenol from 50 to 2500 ng/mL with stronger linearity (R 2 = 0.996 ± 0.003) than the quadrupole-time-of-flight and comparable accuracy (percent error = 4% ± 5). This demonstrates that a quadrupole-time-of-flight can be used for not only qualitative analysis but also targeted quantitation of oxygen-rich lignin molecules in complex mixtures without extensive sample preparation. The rapid and cost-effective method presented here offers new possibilities for bio-oil research, including: (1) allowing for bio-oil studies that demand repetitive analysis as process parameters are changed and (2) making this research accessible to more laboratories. Graphical Abstract ᅟ.

  18. Oncology Nursing Society

    MedlinePlus

    ... Clinical Writing Award Excellence in Writing Award for Quantitative Nursing Research Excellence in Writing Award for Qualitative ... Advisory Panel, Scientific and Research Advocacy Subgroup Research Survey Development Election Information Elect a Leader Candidate Materials ...

  19. Sub-band denoising and spline curve fitting method for hemodynamic measurement in perfusion MRI

    NASA Astrophysics Data System (ADS)

    Lin, Hong-Dun; Huang, Hsiao-Ling; Hsu, Yuan-Yu; Chen, Chi-Chen; Chen, Ing-Yi; Wu, Liang-Chi; Liu, Ren-Shyan; Lin, Kang-Ping

    2003-05-01

    In clinical research, non-invasive MR perfusion imaging is capable of investigating brain perfusion phenomenon via various hemodynamic measurements, such as cerebral blood volume (CBV), cerebral blood flow (CBF), and mean trasnit time (MTT). These hemodynamic parameters are useful in diagnosing brain disorders such as stroke, infarction and periinfarct ischemia by further semi-quantitative analysis. However, the accuracy of quantitative analysis is usually affected by poor signal-to-noise ratio image quality. In this paper, we propose a hemodynamic measurement method based upon sub-band denoising and spline curve fitting processes to improve image quality for better hemodynamic quantitative analysis results. Ten sets of perfusion MRI data and corresponding PET images were used to validate the performance. For quantitative comparison, we evaluate gray/white matter CBF ratio. As a result, the hemodynamic semi-quantitative analysis result of mean gray to white matter CBF ratio is 2.10 +/- 0.34. The evaluated ratio of brain tissues in perfusion MRI is comparable to PET technique is less than 1-% difference in average. Furthermore, the method features excellent noise reduction and boundary preserving in image processing, and short hemodynamic measurement time.

  20. Tunable, Quantitative Fenton-RAFT Polymerization via Metered Reagent Addition.

    PubMed

    Nothling, Mitchell D; McKenzie, Thomas G; Reyhani, Amin; Qiao, Greg G

    2018-05-10

    A continuous supply of radical species is a key requirement for activating chain growth and accessing quantitative monomer conversions in reversible addition-fragmentation chain transfer (RAFT) polymerization. In Fenton-RAFT, activation is provided by hydroxyl radicals, whose indiscriminate reactivity and short-lived nature poses a challenge to accessing extended polymerization times and quantitative monomer conversions. Here, an alternative Fenton-RAFT procedure is presented, whereby radical generation can be finely controlled via metered dosing of a component of the Fenton redox reaction (H 2 O 2 ) using an external pumping system. By limiting the instantaneous flux of radicals and ensuring sustained radical generation over tunable time periods, metered reagent addition reduces unwanted radical "wasting" reactions and provides access to consistent quantitative monomer conversions with high chain-end fidelity. Fine tuning of radical concentration during polymerization is achieved simply via adjustment of reagent dose rate, offering significant potential for automation. This modular strategy holds promise for extending traditional RAFT initiation toward more tightly regulated radical concentration profiles and affords excellent prospects for the automation of Fenton-RAFT polymerization. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Quantitative twoplex glycan analysis using 12C6 and 13C6 stable isotope 2-aminobenzoic acid labelling and capillary electrophoresis mass spectrometry.

    PubMed

    Váradi, Csaba; Mittermayr, Stefan; Millán-Martín, Silvia; Bones, Jonathan

    2016-12-01

    Capillary electrophoresis (CE) offers excellent efficiency and orthogonality to liquid chromatographic (LC) separations for oligosaccharide structural analysis. Combination of CE with high resolution mass spectrometry (MS) for glycan analysis remains a challenging task due to the MS incompatibility of background electrolyte buffers and additives commonly used in offline CE separations. Here, a novel method is presented for the analysis of 2-aminobenzoic acid (2-AA) labelled glycans by capillary electrophoresis coupled to mass spectrometry (CE-MS). To ensure maximum resolution and excellent precision without the requirement for excessive analysis times, CE separation conditions including the concentration and pH of the background electrolyte, the effect of applied pressure on the capillary inlet and the capillary length were evaluated. Using readily available 12/13 C 6 stable isotopologues of 2-AA, the developed method can be applied for quantitative glycan profiling in a twoplex manner based on the generation of extracted ion electropherograms (EIE) for 12 C 6 'light' and 13 C 6 'heavy' 2-AA labelled glycan isotope clusters. The twoplex quantitative CE-MS glycan analysis platform is ideally suited for comparability assessment of biopharmaceuticals, such as monoclonal antibodies, for differential glycomic analysis of clinical material for potential biomarker discovery or for quantitative microheterogeneity analysis of different glycosylation sites within a glycoprotein. Additionally, due to the low injection volume requirements of CE, subsequent LC-MS analysis of the same sample can be performed facilitating the use of orthogonal separation techniques for structural elucidation or verification of quantitative performance.

  2. Direct sampling of sub-µm atmospheric particulate organic matter in sub-ng m-3 mass concentrations by proton-transfer-reaction mass spectrometry

    NASA Astrophysics Data System (ADS)

    Armin, W.; Mueller, M.; Klinger, A.; Striednig, M.

    2017-12-01

    A quantitative characterization of the organic fraction of atmospheric particulate matter is still challenging. Herein we present the novel modular "Chemical Analysis of Aerosol Online" (CHARON) particle inlet system coupled to a new-generation proton-transfer-reaction time-of-flight mass spectrometer (PTR-TOF 6000 X2, Ionicon Analytik, Austria) that quantitatively detects organic analytes in real-time and sub-pptV levels by chemical ionization with hydronium reagent ions. CHARON consists of a gas-phase denuder for stripping off gas-phase analytes (efficiency > 99.999%), an aerodynamic lens for particle collimation combined with an inertial sampler for the particle-enriched flow and a thermodesorption unit for particle volatilization prior to chemical analysis. With typical particle enrichment factors of around 30 for particle diameters (DP) between 120 nm and 1000 nm (somewhat reduced enrichment for 60 nm < DP < 120 nm) we boost the already excellent limits of detection of the PTR-TOF 6000 X2 system to unprecedented levels. We demonstrate that particulate organic analytes of mass concentrations down to 100 pg m-3 can be detected on-line and in single-minute time-resolutions. In addition, PTR-MS allows for a quantitative detection of almost the full range of particulate organics of intermediate to low volatility. With the high mass resolution (R > 6000) and excellent mass accuracies (< 10 ppm) chemical compositions can be assigned and included in further analyses. In addition to a detailed characterization of the CHARON PTR-TOF 6000 X2 we will present first results on the chemical composition of sub-µm particulate organic matter in the urban atmosphere in Innsbruck (Austria).

  3. The Teaching Excellence Framework: Would You Tell Me, Please, Which Way I Ought to Go from Here

    ERIC Educational Resources Information Center

    Berger, Dan; Wild, Charles

    2016-01-01

    The UK government's Green Paper, "Fulfilling Our Potential: Teaching Excellence, Social Mobility and Student Choice", presents both significant challenges and opportunities for universities. Whilst the quantitative element of the proposed Teaching Excellence Framework (TEF), underpinned by Big Data, offers the tantalizing opportunity to…

  4. Microfluidics-based digital quantitative PCR for single-cell small RNA quantification.

    PubMed

    Yu, Tian; Tang, Chong; Zhang, Ying; Zhang, Ruirui; Yan, Wei

    2017-09-01

    Quantitative analyses of small RNAs at the single-cell level have been challenging because of limited sensitivity and specificity of conventional real-time quantitative PCR methods. A digital quantitative PCR (dqPCR) method for miRNA quantification has been developed, but it requires the use of proprietary stem-loop primers and only applies to miRNA quantification. Here, we report a microfluidics-based dqPCR (mdqPCR) method, which takes advantage of the Fluidigm BioMark HD system for both template partition and the subsequent high-throughput dqPCR. Our mdqPCR method demonstrated excellent sensitivity and reproducibility suitable for quantitative analyses of not only miRNAs but also all other small RNA species at the single-cell level. Using this method, we discovered that each sperm has a unique miRNA profile. © The Authors 2017. Published by Oxford University Press on behalf of Society for the Study of Reproduction. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shayduk, Roman; Vonk, Vedran; Strempfer, Jörg

    We report on the quantitative determination of the transient surface temperature of Pt(110) upon nanosecond laser pulse heating. We find excellent agreement between heat transport theory and the experimentally determined transient surface temperature as obtained from time-resolved X-ray diffraction on timescales from hundred nanoseconds to milliseconds. Exact knowledge of the surface temperature's temporal evolution after laser excitation is crucial for future pump-probe experiments at synchrotron storage rings and X-ray free electron lasers.

  6. Projecting technology change to improve space technology planning and systems management

    NASA Astrophysics Data System (ADS)

    Walk, Steven Robert

    2011-04-01

    Projecting technology performance evolution has been improving over the years. Reliable quantitative forecasting methods have been developed that project the growth, diffusion, and performance of technology in time, including projecting technology substitutions, saturation levels, and performance improvements. These forecasts can be applied at the early stages of space technology planning to better predict available future technology performance, assure the successful selection of technology, and improve technology systems management strategy. Often what is published as a technology forecast is simply scenario planning, usually made by extrapolating current trends into the future, with perhaps some subjective insight added. Typically, the accuracy of such predictions falls rapidly with distance in time. Quantitative technology forecasting (QTF), on the other hand, includes the study of historic data to identify one of or a combination of several recognized universal technology diffusion or substitution patterns. In the same manner that quantitative models of physical phenomena provide excellent predictions of system behavior, so do QTF models provide reliable technological performance trajectories. In practice, a quantitative technology forecast is completed to ascertain with confidence when the projected performance of a technology or system of technologies will occur. Such projections provide reliable time-referenced information when considering cost and performance trade-offs in maintaining, replacing, or migrating a technology, component, or system. This paper introduces various quantitative technology forecasting techniques and illustrates their practical application in space technology and technology systems management.

  7. X-Ray and UV Photoelectron Spectroscopy | Materials Science | NREL

    Science.gov Websites

    backsheet material, showing excellent quantitative agreement between measured and predicted peak area ratios quantitative agreement between measured and predicted peak area ratios. Subtle differences in polymer functionality are assessed by deviations from stoichiometry. Elemental Analysis Uses quantitative identification

  8. 40 CFR 796.2750 - Sediment and soil adsorption isotherm.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... are highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...

  9. 40 CFR 796.2750 - Sediment and soil adsorption isotherm.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...

  10. 40 CFR 796.2750 - Sediment and soil adsorption isotherm.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... highly reproducible. The test provides excellent quantitative data readily amenable to statistical... combination of methods suitable for the identification and quantitative detection of the parent test chemical... quantitative analysis of the parent chemical. (3) Amount of parent test chemical applied, the amount recovered...

  11. The Predictive Accuracy of Verbal, Quantitative, and Nonverbal Reasoning Tests: Consequences for Talent Identification and Program Diversity

    ERIC Educational Resources Information Center

    Lakin, Joni M.; Lohman, David F.

    2011-01-01

    Effective talent-identification procedures minimize the proportion of students whose subsequent performance indicates that they were mistakenly included in or excluded from the program. Classification errors occur when students who were predicted to excel subsequently do not excel or when students who were not predicted to excel do. Using a…

  12. Critical methodological factors in diagnosing minimal residual disease in hematological malignancies using quantitative PCR.

    PubMed

    Nyvold, Charlotte Guldborg

    2015-05-01

    Hematological malignancies are a heterogeneous group of cancers with respect to both presentation and prognosis, and many subtypes are nowadays associated with aberrations that make up excellent molecular targets for the quantification of minimal residual disease. The quantitative PCR methodology is outstanding in terms of sensitivity, specificity and reproducibility and thus an excellent choice for minimal residual disease assessment. However, the methodology still has pitfalls that should be carefully considered when the technique is integrated in a clinical setting.

  13. Phase contrast MR angiography techniques.

    PubMed

    Dumoulin, C L

    1995-08-01

    Phase contrast MR methods encode information from macroscopic motion into the phase of the MR signal. Phase contrast methods can be applied with small and large fields-of-view, can give quantitative measures of velocity, and provide excellent suppression of signals from stationary tissue. Unlike time-of-flight methods, phase contrast methods directly measure flow and thus are not hindered by the artifactual appearance of tissue having short T1. Phase contrast angiograms can be two-dimensional (thin slice or projectile), three-dimensional, and/or time resolved and have applications throughout the body.

  14. Analysis of Biomass Sugars Using a Novel HPLC Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agblevor, F. A.; Hames, B. R.; Schell, D.

    The precise quantitative analysis of biomass sugars is a very important step in the conversion of biomass feedstocks to fuels and chemicals. However, the most accurate method of biomass sugar analysis is based on the gas chromatography analysis of derivatized sugars either as alditol acetates or trimethylsilanes. The derivatization method is time consuming but the alternative high-performance liquid chromatography (HPLC) method cannot resolve most sugars found in biomass hydrolysates. We have demonstrated for the first time that by careful manipulation of the HPLC mobile phase, biomass monomeric sugars (arabinose, xylose, fructose, glucose, mannose, and galactose) can be analyzed quantitatively andmore » there is excellent baseline resolution of all the sugars. This method was demonstrated for standard sugars, pretreated corn stover liquid and solid fractions. Our method can also be used to analyze dimeric sugars (cellobiose and sucrose).« less

  15. Evaluation of the Aptima(®) HIV-1 Quant Dx assay for HIV-1 RNA viral load detection and quantitation in plasma of HIV-1-infected individuals: A comparison with Abbott RealTime HIV-1 assay.

    PubMed

    Amendola, Alessandra; Pisciotta, Maria; Aleo, Loredana; Ferraioli, Valeria; Angeletti, Claudio; Capobianchi, Maria Rosaria

    2016-09-01

    The Hologic Aptima(®) HIV-1 Quant Dx assay (Aptima HIV) is a real-time transcription-mediated amplification method CE-approved for use in diagnosis and monitoring of HIV-1 infection. The analytical performance of this new assay was compared to the FDA-approved Abbott RealTime HIV-1 (RealTime). The evaluation was performed using 220 clinical plasma samples, the WHO 3rd HIV-1 International Standard, and the QCMD HIV-1 RNA EQA. Concordance on qualitative results, correlation between quantitative results, accuracy, and reproducibility of viral load data were analyzed. The ability to measure HIV-1 subtypes was assessed on the second WHO International Reference Preparation Panel for HIV-1 Subtypes. With clinical samples, inter-assay agreement for qualitative results was high (91.8%) with Cohen's kappa statistic equal to 0.836. For samples with quantitative results in both assays (n = 93), Lin's concordance correlation coefficient was 0.980 (P < 0.0001) and mean differences of measurement, conducted according to Bland-Altman method, was low (0.115 log10  copies/ml). The Aptima HIV quantified the WHO 3rd HIV-1 International Standard diluted from 2000 to 31 cp/ml (5,700-88 IU/ml) at expected values with excellent linearity (R(2)  > 0.970) and showed higher sensitivity compared to RealTime being able to detect HIV-1 RNA in 10 out of 10 replicates containing down to 7 cp/ml (20 IU/ml). Reproducibility was very high, even at low HIV-1 RNA values. The Aptima HIV was able to detect and accurately quantify all the main HIV-1 subtypes in both reference panels and clinical samples. Besides excellent performance, Aptima HIV shows full automation, ease of use, and improved workflow compared to RealTime. J. Med. Virol. 88:1535-1544, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Precision analysis of a quantitative CT liver surface nodularity score.

    PubMed

    Smith, Andrew; Varney, Elliot; Zand, Kevin; Lewis, Tara; Sirous, Reza; York, James; Florez, Edward; Abou Elkassem, Asser; Howard-Claudio, Candace M; Roda, Manohar; Parker, Ellen; Scortegagna, Eduardo; Joyner, David; Sandlin, David; Newsome, Ashley; Brewster, Parker; Lirette, Seth T; Griswold, Michael

    2018-04-26

    To evaluate precision of a software-based liver surface nodularity (LSN) score derived from CT images. An anthropomorphic CT phantom was constructed with simulated liver containing smooth and nodular segments at the surface and simulated visceral and subcutaneous fat components. The phantom was scanned multiple times on a single CT scanner with adjustment of image acquisition and reconstruction parameters (N = 34) and on 22 different CT scanners from 4 manufacturers at 12 imaging centers. LSN scores were obtained using a software-based method. Repeatability and reproducibility were evaluated by intraclass correlation (ICC) and coefficient of variation. Using abdominal CT images from 68 patients with various stages of chronic liver disease, inter-observer agreement and test-retest repeatability among 12 readers assessing LSN by software- vs. visual-based scoring methods were evaluated by ICC. There was excellent repeatability of LSN scores (ICC:0.79-0.99) using the CT phantom and routine image acquisition and reconstruction parameters (kVp 100-140, mA 200-400, and auto-mA, section thickness 1.25-5.0 mm, field of view 35-50 cm, and smooth or standard kernels). There was excellent reproducibility (smooth ICC: 0.97; 95% CI 0.95, 0.99; CV: 7%; nodular ICC: 0.94; 95% CI 0.89, 0.97; CV: 8%) for LSN scores derived from CT images from 22 different scanners. Inter-observer agreement for the software-based LSN scoring method was excellent (ICC: 0.84; 95% CI 0.79, 0.88; CV: 28%) vs. good for the visual-based method (ICC: 0.61; 95% CI 0.51, 0.69; CV: 43%). Test-retest repeatability for the software-based LSN scoring method was excellent (ICC: 0.82; 95% CI 0.79, 0.84; CV: 12%). The software-based LSN score is a quantitative CT imaging biomarker with excellent repeatability, reproducibility, inter-observer agreement, and test-retest repeatability.

  17. Embroidered electrochemical sensors on gauze for rapid quantification of wound biomarkers.

    PubMed

    Liu, Xiyuan; Lillehoj, Peter B

    2017-12-15

    Electrochemical sensors are an attractive platform for analytical measurements due to their high sensitivity, portability and fast response time. These attributes also make electrochemical sensors well suited for wearable applications which require excellent flexibility and durability. Towards this end, we have developed a robust electrochemical sensor on gauze via a unique embroidery fabrication process for quantitative measurements of wound biomarkers. For proof of principle, this biosensor was used to detect uric acid, a biomarker for wound severity and healing, in simulated wound fluid which exhibits high specificity, good linearly from 0 to 800µM, and excellent reproducibility. Continuous sensing of uric acid was also performed using this biosensor which reveals that it can generate consistent and accurate measurements for up to 7h. Experiments to evaluate the robustness of the embroidered gauze sensor demonstrate that it offers excellent resilience against mechanical stress and deformation, making it a promising wearable platform for assessing and monitoring wound status in situ. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography.

    PubMed

    Shahgaldi, Kambiz; Gudmundsson, Petri; Manouras, Aristomenis; Brodin, Lars-Ake; Winter, Reidar

    2009-08-25

    Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method. Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 +/- 3.7% and -0.2 +/- 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.

  19. Comparison of droplet digital PCR and quantitative real-time PCR for examining population dynamics of bacteria in soil.

    PubMed

    Kim, Tae Gwan; Jeong, So-Yeon; Cho, Kyung-Suk

    2014-07-01

    The newly developed droplet digital PCR (DD-PCR) has shown promise as a DNA quantification technology in medical diagnostic fields. This study evaluated the applicability of DD-PCR as a quantitative tool for soil DNA using quantitative real-time PCR (qRT-PCR) as a reference technology. Cupriavidus sp. MBT14 and Sphingopyxis sp. MD2 were used, and a primer/TaqMan probe set was designed for each (CupMBT and SphMD2, respectively). Standard curve analyses on tenfold dilution series showed that both qRT-PCR and DD-PCR exhibited excellent linearity (R (2) = 1.00) and PCR efficiency (≥92 %) across their detectable ranges. However, DD-PCR showed a tenfold greater sensitivity than qRT-PCR. MBT14 and MD2 were added to non-sterile soil at 0 ~ 5 × 10(8) and 0 ~ 5 × 10(7) cells per gram of soil, respectively (n = 5). This bacterial load test indicated that DD-PCR was more sensitive and discriminating than qRT-PCR. For instance, DD-PCR showed a gradual DNA increase from 14 to 141,160 MBT14 rDNA copies μL DNA extract(-1) as the bacterial load increased, while qRT-PCR could quantify the DNA (6,432 copies μL DNA(-1)) at ≥5 × 10(5) MBT14 per gram of soil. When temporal DNA changes were monitored for 3 weeks in the amended soils, the two technologies exhibited nearly identical changes over time. Linearity tests (y = a · x) revealed excellent quantitative agreement between the two technologies (a = 0.98, R (2) = 0.97 in the CupMBT set and a = 0.90, R (2) = 0.94 in the SphMD2 set). These results suggest that DD-PCR is a promising tool to examine temporal dynamics of microorganisms in complex environments.

  20. Two-dimensional heat flow apparatus

    NASA Astrophysics Data System (ADS)

    McDougall, Patrick; Ayars, Eric

    2014-06-01

    We have created an apparatus to quantitatively measure two-dimensional heat flow in a metal plate using a grid of temperature sensors read by a microcontroller. Real-time temperature data are collected from the microcontroller by a computer for comparison with a computational model of the heat equation. The microcontroller-based sensor array allows previously unavailable levels of precision at very low cost, and the combination of measurement and modeling makes for an excellent apparatus for the advanced undergraduate laboratory course.

  1. Quantitative Gait Measurement With Pulse-Doppler Radar for Passive In-Home Gait Assessment

    PubMed Central

    Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E.

    2014-01-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%–18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment. PMID:24771566

  2. Quantitative gait measurement with pulse-Doppler radar for passive in-home gait assessment.

    PubMed

    Wang, Fang; Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E

    2014-09-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%-18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment.

  3. Quantitation of sugar content in pyrolysis liquids after acid hydrolysis using high-performance liquid chromatography without neutralization.

    PubMed

    Johnston, Patrick A; Brown, Robert C

    2014-08-13

    A rapid method for the quantitation of total sugars in pyrolysis liquids using high-performance liquid chromatography (HPLC) was developed. The method avoids the tedious and time-consuming sample preparation required by current analytical methods. It is possible to directly analyze hydrolyzed pyrolysis liquids, bypassing the neutralization step usually required in determination of total sugars. A comparison with traditional methods was used to determine the validity of the results. The calibration curve coefficient of determination on all standard compounds was >0.999 using a refractive index detector. The relative standard deviation for the new method was 1.13%. The spiked sugar recoveries on the pyrolysis liquid samples were between 104 and 105%. The research demonstrates that it is possible to obtain excellent accuracy and efficiency using HPLC to quantitate glucose after acid hydrolysis of polymeric and oligomeric sugars found in fast pyrolysis bio-oils without neutralization.

  4. Tissue Characterization with Quantitative High-Resolution Magic Angle Spinning Chemical Exchange Saturation Transfer Z-Spectroscopy.

    PubMed

    Zhou, Iris Yuwen; Fuss, Taylor L; Igarashi, Takahiro; Jiang, Weiping; Zhou, Xin; Cheng, Leo L; Sun, Phillip Zhe

    2016-11-01

    Chemical exchange saturation transfer (CEST) provides sensitive magnetic resonance (MR) contrast for probing dilute compounds via exchangeable protons, serving as an emerging molecular imaging methodology. CEST Z-spectrum is often acquired by sweeping radiofrequency saturation around bulk water resonance, offset by offset, to detect CEST effects at characteristic chemical shift offsets, which requires prolonged acquisition time. Herein, combining high-resolution magic angle spinning (HRMAS) with concurrent application of gradient and rf saturation to achieve fast Z-spectral acquisition, we demonstrated the feasibility of fast quantitative HRMAS CEST Z-spectroscopy. The concept was validated with phantoms, which showed excellent agreement with results obtained from conventional HRMAS MR spectroscopy (MRS). We further utilized the HRMAS Z-spectroscopy for fast ex vivo quantification of ischemic injury with rodent brain tissues after ischemic stroke. This method allows rapid and quantitative CEST characterization of biological tissues and shows potential for a host of biomedical applications.

  5. Development and Application of an MSALL-Based Approach for the Quantitative Analysis of Linear Polyethylene Glycols in Rat Plasma by Liquid Chromatography Triple-Quadrupole/Time-of-Flight Mass Spectrometry.

    PubMed

    Zhou, Xiaotong; Meng, Xiangjun; Cheng, Longmei; Su, Chong; Sun, Yantong; Sun, Lingxia; Tang, Zhaohui; Fawcett, John Paul; Yang, Yan; Gu, Jingkai

    2017-05-16

    Polyethylene glycols (PEGs) are synthetic polymers composed of repeating ethylene oxide subunits. They display excellent biocompatibility and are widely used as pharmaceutical excipients. To fully understand the biological fate of PEGs requires accurate and sensitive analytical methods for their quantitation. Application of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) is difficult because PEGs have polydisperse molecular weights (MWs) and tend to produce multicharged ions in-source resulting in innumerable precursor ions. As a result, multiple reaction monitoring (MRM) fails to scan all ion pairs so that information on the fate of unselected ions is missed. This Article addresses this problem by application of liquid chromatography-triple-quadrupole/time-of-flight mass spectrometry (LC-Q-TOF MS) based on the MS ALL technique. This technique performs information-independent acquisition by allowing all PEG precursor ions to enter the collision cell (Q2). In-quadrupole collision-induced dissociation (CID) in Q2 then effectively generates several fragments from all PEGs due to the high collision energy (CE). A particular PEG product ion (m/z 133.08592) was found to be common to all linear PEGs and allowed their total quantitation in rat plasma with high sensitivity, excellent linearity and reproducibility. Assay validation showed the method was linear for all linear PEGs over the concentration range 0.05-5.0 μg/mL. The assay was successfully applied to the pharmacokinetic study in rat involving intravenous administration of linear PEG 600, PEG 4000, and PEG 20000. It is anticipated the method will have wide ranging applications and stimulate the development of assays for other pharmaceutical polymers in the future.

  6. An Excel-Aided Method for Teaching Calculus-Based Business Mathematics

    ERIC Educational Resources Information Center

    Liang, Jiajuan; Martin, Linda

    2008-01-01

    Calculus-based business mathematics is a required quantitative course for undergraduate business students in most AACSB accredited schools or colleges of business. Many business students, however, have relatively weak mathematical background or even display math-phobia when presented with calculus problems. Because of the popularity of Excel, its…

  7. Quantitative Framework and Management Expectation Tool for the Selection of Bioremediation Approaches at Chlorinated Solvent Sites

    DTIC Science & Technology

    2015-03-19

    to Abiotic Degradation  Magnetite (FeO.Fe2O3) often occurs naturally in sediments formed by weathering of igneous or metamorphic rock  Magnetite...send questions at any time using the Q&A panel 6 SERDP & ESTCP Webinar Series (#11) SERDP & ESTCP Webinar Series SERDP and ESTCP Overview Andrea...Attenuation (MNA)  Integrate the decision-making framework into an easy to use application • Excel spreadsheet  Guide users in the selection of

  8. Elevation-relief ratio, hypsometric integral, and geomorphic area-altitude analysis.

    NASA Technical Reports Server (NTRS)

    Pike, R. J.; Wilson, S. E.

    1971-01-01

    Mathematical proof establishes identity of hypsometric integral and elevation-relief ratio, two quantitative topographic descriptors developed independently of one another for entirely different purposes. Operationally, values of both measures are in excellent agreement for arbitrarily bounded topographic samples, as well as for low-order fluvial watersheds. By using a point-sampling technique rather than planimetry, elevation-relief ratio (defined as mean elevation minus minimum elevation divided by relief) is calculated manually in about a third of the time required for the hypsometric integral.

  9. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography

    PubMed Central

    Shahgaldi, Kambiz; Gudmundsson, Petri; Manouras, Aristomenis; Brodin, Lars-Åke; Winter, Reidar

    2009-01-01

    Background Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method. Methods Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. Results There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 ± 3.7% and -0.2 ± 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Conclusion Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant. PMID:19706183

  10. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.

  11. Trace-Level Volatile Quantitation by Direct Analysis in Real Time Mass Spectrometry following Headspace Extraction: Optimization and Validation in Grapes.

    PubMed

    Jastrzembski, Jillian A; Bee, Madeleine Y; Sacks, Gavin L

    2017-10-25

    Ambient ionization mass spectrometric (AI-MS) techniques like direct analysis in real time (DART) offer the potential for rapid quantitative analyses of trace volatiles in food matrices, but performance is generally limited by the lack of preconcentration and extraction steps. The sensitivity and selectivity of AI-MS approaches can be improved through solid-phase microextraction (SPME) with appropriate thin-film geometries, for example, solid-phase mesh-enhanced sorption from headspace (SPMESH). This work improves the SPMESH-DART-MS approach for use in food analyses and validates the approach for trace volatile analysis for two compounds in real samples (grape macerates). SPMESH units prepared with different sorbent coatings were evaluated for their ability to extract a range of odor-active volatiles, with poly(dimethylsiloxane)/divinylbenzene giving the most satisfactory results. In combination with high-resolution mass spectrometry (HRMS), detection limits for SPMESH-DART-MS under 4 ng/L in less than 30 s acquisition times could be achieved for some volatiles [3-isobutyl-2-methoxypyrazine (IBMP) and β-damascenone]. A comparison of SPMESH-DART-MS and SPME-GC-MS quantitation of linalool and IBMP demonstrates excellent agreement between the two methods for real grape samples (r 2 ≥ 0.90), although linalool measurements appeared to also include isobaric interference.

  12. Teaching Excellence Awards: An Apple for the Teacher?

    ERIC Educational Resources Information Center

    Mackenzie, Noella

    2007-01-01

    In this article the status of teaching as a profession and the morale of teachers in Australian schools in the current era provide a framework for the examination of the intent and outcomes of teaching excellence awards. The research study applied an interpretive research paradigm and used both qualitative and quantitative data collection methods.…

  13. Application of solid-phase microextraction to the quantitative analysis of 1,8-cineole in blood and expired air in a Eucalyptus herbivore, the brushtail possum (Trichosurus vulpecula).

    PubMed

    Boyle, Rebecca R; McLean, Stuart; Brandon, Sue; Pass, Georgia J; Davies, Noel W

    2002-11-25

    We have developed two solid-phase microextraction (SPME) methods, coupled with gas chromatography, for quantitatively analysing the major Eucalyptus leaf terpene, 1,8-cineole, in both expired air and blood from the common brushtail possum (Trichosurus vulpecula). In-line SPME sampling (5 min at 20 degrees C room temperature) of excurrent air from an expiratory chamber containing a possum dosed orally with 1,8-cineole (50 mg/kg) allowed real-time semi-quantitative measurements reflecting 1,8-cineole blood concentrations. Headspace SPME using 50 microl whole blood collected from possums dosed orally with 1,8-cineole (30 mg/kg) resulted in excellent sensitivity (quantitation limit 1 ng/ml) and reproducibility. Blood concentrations ranged between 1 and 1380 ng/ml. Calibration curves were prepared for two concentration ranges (0.05-10 and 10-400 ng/50 microl) for the analysis of blood concentrations. Both calibration curves were linear (r(2)=0.999 and 0.994, respectively) and the equations for the two concentration ranges were consistent. Copyright 2002 Elsevier Science B.V.

  14. A tutorial on the use of Excel 2010 and Excel for Mac 2011 for conducting delay-discounting analyses.

    PubMed

    Reed, Derek D; Kaplan, Brent A; Brewer, Adam T

    2012-01-01

    In recent years, researchers and practitioners in the behavioral sciences have profited from a growing literature on delay discounting. The purpose of this article is to provide readers with a brief tutorial on how to use Microsoft Office Excel 2010 and Excel for Mac 2011 to analyze discounting data to yield parameters for both the hyperbolic discounting model and area under the curve. This tutorial is intended to encourage the quantitative analysis of behavior in both research and applied settings by readers with relatively little formal training in nonlinear regression.

  15. A TUTORIAL ON THE USE OF EXCEL 2010 AND EXCEL FOR MAC 2011 FOR CONDUCTING DELAY-DISCOUNTING ANALYSES

    PubMed Central

    Reed, Derek D; Kaplan, Brent A; Brewer, Adam T

    2012-01-01

    In recent years, researchers and practitioners in the behavioral sciences have profited from a growing literature on delay discounting. The purpose of this article is to provide readers with a brief tutorial on how to use Microsoft Office Excel 2010 and Excel for Mac 2011 to analyze discounting data to yield parameters for both the hyperbolic discounting model and area under the curve. This tutorial is intended to encourage the quantitative analysis of behavior in both research and applied settings by readers with relatively little formal training in nonlinear regression. PMID:22844143

  16. Doing Quantitative Research in Education with SPSS Second edition Daniel Muijs Doing Quantitative Research in Education with SPSS Second edition £24.99 264pp 9781849203241 1849203245 [Formula: see text].

    PubMed

    2012-07-19

    THIS TEXT is a straightforward, no nonsense guide for novice researchers venturing into research involving quantitative methodologies. It is also an excellent resource to refresh more experienced researchers. It is well written in plain English and encourages researchers to carry out their own analyses.

  17. Test-retest reliability of quantitative sensory testing for mechanical somatosensory and pain modulation assessment of masticatory structures.

    PubMed

    Costa, Y M; Morita-Neto, O; de Araújo-Júnior, E N S; Sampaio, F A; Conti, P C R; Bonjardim, L R

    2017-03-01

    Assessing the reliability of medical measurements is a crucial step towards the elaboration of an applicable clinical instrument. There are few studies that evaluate the reliability of somatosensory assessment and pain modulation of masticatory structures. This study estimated the test-retest reliability, that is over time, of the mechanical somatosensory assessment of anterior temporalis, masseter and temporomandibular joint (TMJ) and the conditioned pain modulation (CPM) using the anterior temporalis as the test site. Twenty healthy women were evaluated in two sessions (1 week apart) by the same examiner. Mechanical detection threshold (MDT), mechanical pain threshold (MPT), wind-up ratio (WUR) and pressure pain threshold (PPT) were assessed on the skin overlying the anterior temporalis, masseter and TMJ of the dominant side. CPM was tested by comparing PPT before and during the hand immersion in a hot water bath. anova and intra-class correlation coefficients (ICCs) were applied to the data (α = 5%). The overall ICCs showed acceptable values for the test-retest reliability of mechanical somatosensory assessment of masticatory structures. The ICC values of 75% of all quantitative sensory measurements were considered fair to excellent (fair = 8·4%, good = 33·3% and excellent = 33·3%). However, the CPM paradigm presented poor reliability (ICC = 0·25). The mechanical somatosensory assessment of the masticatory structures, but not the proposed CPM protocol, can be considered sufficiently reliable over time to evaluate the trigeminal sensory function. © 2016 John Wiley & Sons Ltd.

  18. Continuous EEG monitoring in the intensive care unit.

    PubMed

    Scheuer, Mark L

    2002-01-01

    Continuous EEG (CEEG) monitoring allows uninterrupted assessment of cerebral cortical activity with good spatial resolution and excellent temporal resolution. Thus, this procedure provides a means of constantly assessing brain function in critically ill obtunded and comatose patients. Recent advances in digital EEG acquisition, storage, quantitative analysis, and transmission have made CEEG monitoring in the intensive care unit (ICU) technically feasible and useful. This article summarizes the indications and methodology of CEEG monitoring in the ICU, and discusses the role of some quantitative EEG analysis techniques in near real-time remote observation of CEEG recordings. Clinical examples of CEEG use, including monitoring of status epilepticus, assessment of ongoing therapy for treatment of seizures in critically ill patients, and monitoring for cerebral ischemia, are presented. Areas requiring further development of CEEG monitoring techniques and indications are discussed.

  19. Using Microsoft Office Excel 2007 to conduct generalized matching analyses.

    PubMed

    Reed, Derek D

    2009-01-01

    The generalized matching equation is a robust and empirically supported means of analyzing relations between reinforcement and behavior. Unfortunately, no simple task analysis is available to behavior analysts interested in using the matching equation to evaluate data in clinical or applied settings. This technical article presents a task analysis for the use of Microsoft Excel to analyze and plot the generalized matching equation. Using a data-based case example and a step-by-step guide for completing the analysis, these instructions are intended to promote the use of quantitative analyses by researchers with little to no experience in quantitative analyses or the matching law.

  20. An integrated microfluidic sensor for real-time detection of RNA in seawater using preserved reagents

    NASA Astrophysics Data System (ADS)

    Tsaloglou, M.-N.; Loukas, C. M.; Ruano-López, J. M.; Morgan, H.; Mowlem, M. C.

    2012-04-01

    Quantitation of RNA sequences coding either for key metabolic proteins or highly conserved ribosomal subunits can provide insight on cell abundance, speciation and viability. Nucleic sequence-based amplification (NASBA) is an isothermal alternative to traditional nucleic acid amplification methods, such as quantitative PCR. We present here an integrated microfluidic sensor for cell concentration and lysis, RNA extraction/purification and quantitative RNA detection for environmental applications. The portable system uses pre-loaded reagents, stored as a gel on a disposable microfluidic cartridge, which is manufactured using low-cost injection moulding. The NASBA reaction is monitored real-time using a bespoke control unit which includes: an external fluorescence detector, three peristaltic micro-pumps, two heaters and temperature sensors, a battery, seven pin actuated micro-motors (or valve actuators), and an automatic cartridge insertion mechanism. The system has USB connectivity and none of the expensive components require replacing between reactions. Long-term storage of reagents is critically important for any diagnostic tool that will be used in the field, whether for medical or environmental analysis and has not been previously demonstrated for NASBA reagents on-chip. We have shown effective amplification, for as little as 500 cells of the toxic microalga Karenia brevis using reagents which had been preserved as a gel for 45 days. This is the first reported real-time isothermal RNA amplification using with on-chip preservation. Annealing of primers, amplification at 41 °C and real-time fluorescence detection using, also for the first time, an internal control and sequence-specific molecular beacons was all performed on our microfluidic sensor. Our results show excellent promise as a future quantitative tool of in situ phytoplankton analysis and other environmental applications, where long-term reagent storage and low power consumption is essential.

  1. Quantifying Qualitative Data Using Cognitive Maps

    ERIC Educational Resources Information Center

    Scherp, Hans-Ake

    2013-01-01

    The aim of the article is to show how substantial qualitative material consisting of graphic cognitive maps can be analysed by using digital CmapTools, Excel and SPSS. Evidence is provided of how qualitative and quantitative methods can be combined in educational research by transforming qualitative data into quantitative data to facilitate…

  2. Widefield quantitative multiplex surface enhanced Raman scattering imaging in vivo

    NASA Astrophysics Data System (ADS)

    McVeigh, Patrick Z.; Mallia, Rupananda J.; Veilleux, Israel; Wilson, Brian C.

    2013-04-01

    In recent years numerous studies have shown the potential advantages of molecular imaging in vitro and in vivo using contrast agents based on surface enhanced Raman scattering (SERS), however the low throughput of traditional point-scanned imaging methodologies have limited their use in biological imaging. In this work we demonstrate that direct widefield Raman imaging based on a tunable filter is capable of quantitative multiplex SERS imaging in vivo, and that this imaging is possible with acquisition times which are orders of magnitude lower than achievable with comparable point-scanned methodologies. The system, designed for small animal imaging, has a linear response from (0.01 to 100 pM), acquires typical in vivo images in <10 s, and with suitable SERS reporter molecules is capable of multiplex imaging without compensation for spectral overlap. To demonstrate the utility of widefield Raman imaging in biological applications, we show quantitative imaging of four simultaneous SERS reporter molecules in vivo with resulting probe quantification that is in excellent agreement with known quantities (R2>0.98).

  3. Quantitation of O6-methylguanine-DNA methyltransferase gene messenger RNA in gliomas by means of real-time RT-PCR and clinical response to nitrosoureas.

    PubMed

    Tanaka, Satoshi; Oka, Hidehiro; Fujii, Kiyotaka; Watanabe, Kaoru; Nagao, Kumi; Kakimoto, Atsushi

    2005-09-01

    1. O6-methylguanine-DNA methyltransferase (MGMT) mRNA was measured in 50 malignant gliomas that had received 1-(4-amino-2-methyl-5-pyrimidynyl) methyl-3-(2-chloroethyl)-3-nitrosourea hydrochloride (ACNU) after the resection of the tumor by real-time reverse transcription-polymerase chain reaction (RT-PCR) using TaqMan probe. 2. The mean absolute value of MGMTmRNA normalized to the level of glyceraldehyde-3-phosphate dehydrogenase (GAPDH) for 50 tumors was 1.29 x 10(4)+/- 1.28 x 10(4) copy/microg RNA (mean +/- SD). The amount of MGMTmRNA less than 6 x 10(3) copy/microg RNA was the most significant factor in predicting the initial effect of treatment with ACNU by multi-variant regression analysis (p = 0.0157). 3. These results suggest that quantitation of MGMTmRNA is the excellent method for predicting for the effect of ACNU in glioma therapy.

  4. Quantitative evaluation of spatial scale of carrier trapping at grain boundary by GHz-microwave dielectric loss spectroscopy

    NASA Astrophysics Data System (ADS)

    Choi, W.; Tsutsui, Y.; Miyakai, T.; Sakurai, T.; Seki, S.

    2017-11-01

    Charge carrier mobility is an important primary parameter for the electronic conductive materials, and the intrinsic limit of the mobility has been hardly access by conventional direct-current evaluation methods. In the present study, intra-grain hole mobility of pentacene thin films was estimated quantitatively using microwave-based dielectric loss spectroscopy (time-resolved microwave conductivity measurement) in alternating current mode of charge carrier local motion. Metal-insulator-semiconductor devices were prepared with different insulating polymers or substrate temperature upon vacuum deposition of the pentacene layer, which afforded totally four different grain-size conditions of pentacene layers. Under the condition where the local motion was determined by interfacial traps at the pentacene grain boundaries (grain-grain interfaces), the observed hole mobilities were plotted against the grain sizes, giving an excellent correlation fit successfully by a parabolic function representative of the boarder length. Consequently, the intra-grain mobility and trap-release time of holes were estimated as 15 cm2 V-1 s-1 and 9.4 ps.

  5. Air Monitoring for Hazardous Gas Detection

    NASA Technical Reports Server (NTRS)

    Arkin, C. Richard; Griffin, Timothy P.; Adams, Frederick W.; Naylor, Guy; Haskell, William; Floyd, David; Curley, Charles; Follistein, Duke W.

    2004-01-01

    The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and quantify various hazardous gases. Traditionally these systems are designed for leak detection of the cryogenic gases used for the propulsion of the Shuttle and other vehicles. Mass spectrometers are the basis of these systems, which provide excellent quantitation, sensitivity, selectivity, response times and detection limits. A Table lists common gases monitored for aerospace applications. The first five gases, hydrogen, helium, nitrogen, oxygen, and argon are historically the focus of the HGDL.

  6. Ability of walking without a walking device in patients with spinal cord injury as determined using data from functional tests

    PubMed Central

    Poncumhak, Puttipong; Saengsuwan, Jiamjit; Amatachaya, Sugalya

    2014-01-01

    Background/Objectives More than half of independent ambulatory patients with spinal cord injury (SCI) need a walking device to promote levels of independence. However, long-lasting use of a walking device may introduce negative impacts for the patients. Using a standard objective test relating to the requirement of a walking device may offer a quantitative criterion to effectively monitor levels of independence of the patients. Therefore, this study investigated (1) ability of the three functional tests, including the five times sit-to-stand test (FTSST), timed up and go test (TUGT), and 10-meter walk test (10MWT) to determine the ability of walking without a walking device, and (2) the inter-tester reliability of the tests to assess functional ability in patients with SCI. Methods Sixty independent ambulatory patients with SCI, who walked with and without a walking device (30 subjects/group), were assessed cross-sectionally for their functional ability using the three tests. The first 20 subjects also participated in the inter-tester reliability test. Results The time required to complete the FTSST <14 seconds, the TUGT < 18 seconds, and the 10MWT < 6 seconds had good-to-excellent capability to determine the ability of walking without a walking device of subjects with SCI. These tests also showed excellent inter-tester reliability. Conclusions Methods of clinical evaluation for walking are likely performed using qualitative observation, which makes the results difficult to compare among testers and test intervals. Findings of this study offer a quantitative target criterion or a clear level of ability that patients with SCI could possibly walk without a walking device, which would benefit monitoring process for the patients. PMID:24621030

  7. Reviews

    NASA Astrophysics Data System (ADS)

    2006-03-01

    WE RECOMMEND It’s About Time: Understanding Einstein’s Relativity An excellent novel explanation of special relativity. The Plane Factory A great way to make projects more quantitative. Spacesaver Microvoltmeter This meter is robust, portable and covers a good range of voltages. Cassell’s Laws of Nature This book covers everything that governs our physical universe. J D Bernal: The Sage of Science Awell researched biography that is hard to put down. AS-Level Physics: The Revision Guide A very good, reasonably priced revision guide. WORTH A LOOK Symmetry and the Beautiful Universe This book on modern physics is fairly readable but a bit haphazard. HANDLE WITH CARE Hover Football An inferior and cheaper version of the Kick Dis. art & science Art students will get more out of this than physics students. WEB WATCH Practicalphysics.org is an excellent site, packed with useful tips and instructions for practical physics experiments. Louisa Jones describes her favourite websites about waves

  8. Validation of MODIS Aerosol Optical Depth Retrieval Over Land

    NASA Technical Reports Server (NTRS)

    Chu, D. A.; Kaufman, Y. J.; Ichoku, C.; Remer, L. A.; Tanre, D.; Holben, B. N.; Einaudi, Franco (Technical Monitor)

    2001-01-01

    Aerosol optical depths are derived operationally for the first time over land in the visible wavelengths by MODIS (Moderate Resolution Imaging Spectroradiometer) onboard the EOSTerra spacecraft. More than 300 Sun photometer data points from more than 30 AERONET (Aerosol Robotic Network) sites globally were used in validating the aerosol optical depths obtained during July - September 2000. Excellent agreement is found with retrieval errors within (Delta)tau=+/- 0.05 +/- 0.20 tau, as predicted, over (partially) vegetated surfaces, consistent with pre-launch theoretical analysis and aircraft field experiments. In coastal and semi-arid regions larger errors are caused predominantly by the uncertainty in evaluating the surface reflectance. The excellent fit was achieved despite the ongoing improvements in instrument characterization and calibration. This results show that MODIS-derived aerosol optical depths can be used quantitatively in many applications with cautions for residual clouds, snow/ice, and water contamination.

  9. Experimental characterization of the transition to coherence collapse in a semiconductor laser with optical feedback

    NASA Astrophysics Data System (ADS)

    Panozzo, M.; Quintero-Quiroz, C.; Tiana-Alsina, J.; Torrent, M. C.; Masoller, C.

    2017-11-01

    Semiconductor lasers with time-delayed optical feedback display a wide range of dynamical regimes, which have found various practical applications. They also provide excellent testbeds for data analysis tools for characterizing complex signals. Recently, several of us have analyzed experimental intensity time-traces and quantitatively identified the onset of different dynamical regimes, as the laser current increases. Specifically, we identified the onset of low-frequency fluctuations (LFFs), where the laser intensity displays abrupt dropouts, and the onset of coherence collapse (CC), where the intensity fluctuations are highly irregular. Here we map these regimes when both, the laser current and the feedback strength vary. We show that the shape of the distribution of intensity fluctuations (characterized by the standard deviation, the skewness, and the kurtosis) allows to distinguish among noise, LFFs and CC, and to quantitatively determine (in spite of the gradual nature of the transitions) the boundaries of the three regimes. Ordinal analysis of the inter-dropout time intervals consistently identifies the three regimes occurring in the same parameter regions as the analysis of the intensity distribution. Simulations of the well-known time-delayed Lang-Kobayashi model are in good qualitative agreement with the observations.

  10. Three-Capital Approach to the Study of Young People Who Excel in Vocational Occupations: A Case of WorldSkills Competitors and Entrepreneurship

    ERIC Educational Resources Information Center

    Chankseliani, Maia; Relly, Susan James

    2016-01-01

    This paper examines the entrepreneurial inclinations of young people who achieved excellence in vocational occupations. We propose a three-capital approach to the study of entrepreneurship. Relying on the existing theories and original qualitative and quantitative data analyses, findings from interviews with 30 entrepreneurial and 10…

  11. The Relationship between Teachers' Performance on the Ventures for Excellence and Their Teaching Effectiveness

    ERIC Educational Resources Information Center

    Winters, Michael Joseph

    2017-01-01

    This quantitative correlational study examined the relationship between teacher pre-hiring effectiveness evaluation and their performance evaluation scores at the end of the first year of teaching. Prior to this study, it was not known if and to what degree teachers' scores on the Ventures for Excellence B-22 screening interview correlated to…

  12. Development of a SYBR Green I real-time PCR for detection and quantitation of orthopoxvirus by using Ectromelia virus.

    PubMed

    Cheng, Wenyu; He, Xiaobing; Jia, Huaijie; Chen, Guohua; Wang, Cong; Zhang, Jun; Jing, Zhizhong

    2018-04-01

    Ectromelia virus (ECTV) is the causative agent of mousepox, which has devastating effects in laboratory-mouse colonies and causes economic loss in biomedical research. More importantly, ECTV has been extensively used as an excellent model for studies of the pathogenesis and immunobiology of human smallpox. A rapid and sensitive SYBR Green I-based real-time PCR assay was developed and used for the detection and quantitation of orthopoxvirus by using ECTV in this study. Primers targeted to the highly conserved region of major core protein P4b gene of orthopoxvirus were designed and the standard plasmid was constructed. This assay was able to detect a minimum of 10 copies of standard DNA and 5 TCID 50 units of ECTV. In addition, no cross-reactions were observed with two DNA viruses, such as herpes simplex virus and swine pseudorabies virus, and one RNA virus, vesicular stomatitis virus. Furthermore, intra- and inter-assay variability data showed that this method had a highly reproducibility and reliability. Moreover, the current assay was faster and had a higher sensitivity for detection of ECTV genomic DNA in cell cultured and clinical test samples. Therefore, the high sensitivity and reproducibility of this SYBR Green real-time PCR approach is a more effective method than the conventional PCR for ECTV diagnosis and quantitation. Copyright © 2017. Published by Elsevier Ltd.

  13. Relative quantitation of glycosylation variants by stable isotope labeling of enzymatically released N-glycans using [12C]/[13C] aniline and ZIC-HILIC-ESI-TOF-MS.

    PubMed

    Giménez, Estela; Sanz-Nebot, Victòria; Rizzi, Andreas

    2013-09-01

    Glycan reductive isotope labeling (GRIL) using [(12)C]- and [(13)C]-coded aniline was used for relative quantitation of N-glycans. In a first step, the labeling method by reductive amination was optimized for this reagent. It could be demonstrated that selecting aniline as limiting reactant and using the reductant in excess is critical for achieving high derivatization yields (over 95 %) and good reproducibility (relative standard deviations ∼1-5 % for major and ∼5-10 % for minor N-glycans). In a second step, zwitterionic-hydrophilic interaction liquid chromatography in capillary columns coupled to electrospray mass spectrometry with time-of-flight analyzer (μZIC-HILIC-ESI-TOF-MS) was applied for the analysis of labeled N-glycans released from intact glycoproteins. Ovalbumin, bovine α1-acid-glycoprotein and bovine fetuin were used as test glycoproteins to establish and evaluate the methodology. Excellent separation of isomeric N-glycans and reproducible quantitation via the extracted ion chromatograms indicate a great potential of the proposed methodology for glycoproteomic analysis and for reliable relative quantitation of glycosylation variants in biological samples.

  14. IBMISPS (International Brain Mapping & Intraoperative Surgical Planning Symposium)

    DTIC Science & Technology

    2005-12-01

    they received the 2005 Excellence in R, D & E award for their contribution in the feild of prosthetics and brain imaging. Excellence in Educational...specific bipolar magnetic gradient pulses which measure the velocity vector components of motion. Presented here are the development of dynamic MR...movies of quantitative velocity vector components, 30 frames per second. The 3 velocity vector maps with tensor analysis produced maps of the

  15. Quantitative developmental transcriptomes of the Mediterranean sea urchin Paracentrotus lividus.

    PubMed

    Gildor, Tsvia; Malik, Assaf; Sher, Noa; Avraham, Linor; Ben-Tabou de-Leon, Smadar

    2016-02-01

    Embryonic development progresses through the timely activation of thousands of differentially activated genes. Quantitative developmental transcriptomes provide the means to relate global patterns of differentially expressed genes to the emerging body plans they generate. The sea urchin is one of the classic model systems for embryogenesis and the models of its developmental gene regulatory networks are of the most comprehensive of their kind. Thus, the sea urchin embryo is an excellent system for studies of its global developmental transcriptional profiles. Here we produced quantitative developmental transcriptomes of the sea urchin Paracentrotus lividus (P. lividus) at seven developmental stages from the fertilized egg to prism stage. We generated de-novo reference transcriptome and identified 29,817 genes that are expressed at this time period. We annotated and quantified gene expression at the different developmental stages and confirmed the reliability of the expression profiles by QPCR measurement of a subset of genes. The progression of embryo development is reflected in the observed global expression patterns and in our principle component analysis. Our study illuminates the rich patterns of gene expression that participate in sea urchin embryogenesis and provide an essential resource for further studies of the dynamic expression of P. lividus genes. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Quantitative monitoring of HCMV DNAlactia in human milk by real time PCR assay: Implementation of internal control contributes to standardization and quality control.

    PubMed

    Hartleif, Steffen; Göhring, Katharina; Goelz, Rangmar; Jahn, Gerhard; Hamprecht, Klaus

    2016-11-01

    For cytomegalovirus screening of breastfeeding mothers of preterm infants under risk, we present a rapid, quantitative real-time PCR protocol using the hybridization format of the viral gB target region. For quantification, we used an external gB fragment cloned into a vector system. For standardization, we created an internal control-plasmid by site-directed mutagenesis with an exchange of 9 nucleotides. Spiked with internal control, patient wildtype amplicons could be discriminated from internal controls by hybridization probes using two-channel fluorescence detection. Potential bias of formerly reported false nucleotide sequence data of gB-hybridization probes was excluded. Using this approach, we could demonstrate excellent analytical performance and high reproducibility of HCMV detection during lactation. This assay shows very good correlation with a commercial quantitative HCMV DNA PCR and may help to identify rapidly HCMV shedding mothers of very low birth weight preterm infants to prevent HCMV transmission. On the other hand, negative DNA amplification results allow feeding of milk samples of seropositive mothers to their preterm infants under risk (<30 weeks of gestational age, <1000g birth weight) during the onset and late stage of HCMV shedding during lactation. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Some Recent Developments in the Endochronic Theory with Application to Cyclic Histories

    NASA Technical Reports Server (NTRS)

    Valanis, K. C.; Lee, C. F.

    1983-01-01

    Constitutive equations with only two easily determined material constants predict the stress (strain) response of normalized mild steel to a variety of general strain (stress) histories, without a need for special unloading-reloading rules. The equations are derived from the endochronic theory of plasticity of isotropic materials with an intrinsic time scale defined in the plastic strain space. Agreement between theoretical predictions and experiments are are excellent quantitatively in cases of various uniaxial constant amplitude histories, variable uniaxial strain amplitude histories and cyclic relaxation. The cyclic ratcheting phenomenon is predicted by the present theory.

  18. Direct measurements of protein-stabilized gold nanoparticle interactions.

    PubMed

    Eichmann, Shannon L; Bevan, Michael A

    2010-09-21

    We report integrated video and total internal reflection microscopy measurements of protein stabilized 110 nm Au nanoparticles confined in 280 nm gaps in physiological media. Measured potential energy profiles display quantitative agreement with Brownian dynamic simulations that include hydrodynamic interactions and camera exposure time and noise effects. Our results demonstrate agreement between measured nonspecific van der Waals and adsorbed protein interactions with theoretical potentials. Confined, lateral nanoparticle diffusivity measurements also display excellent agreement with predictions. These findings provide a basis to interrogate specific biomacromolecular interactions in similar experimental configurations and to design future improved measurement methods.

  19. Quantitative mutant analysis of viral quasispecies by chip-based matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry

    PubMed Central

    Amexis, Georgios; Oeth, Paul; Abel, Kenneth; Ivshina, Anna; Pelloquin, Francois; Cantor, Charles R.; Braun, Andreas; Chumakov, Konstantin

    2001-01-01

    RNA viruses exist as quasispecies, heterogeneous and dynamic mixtures of mutants having one or more consensus sequences. An adequate description of the genomic structure of such viral populations must include the consensus sequence(s) plus a quantitative assessment of sequence heterogeneities. For example, in quality control of live attenuated viral vaccines, the presence of even small quantities of mutants or revertants may indicate incomplete or unstable attenuation that may influence vaccine safety. Previously, we demonstrated the monitoring of oral poliovirus vaccine with the use of mutant analysis by PCR and restriction enzyme cleavage (MAPREC). In this report, we investigate genetic variation in live attenuated mumps virus vaccine by using both MAPREC and a platform (DNA MassArray) based on matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Mumps vaccines prepared from the Jeryl Lynn strain typically contain at least two distinct viral substrains, JL1 and JL2, which have been characterized by full length sequencing. We report the development of assays for characterizing sequence variants in these substrains and demonstrate their use in quantitative analysis of substrains and sequence variations in mixed virus cultures and mumps vaccines. The results obtained from both the MAPREC and MALDI-TOF methods showed excellent correlation. This suggests the potential utility of MALDI-TOF for routine quality control of live viral vaccines and for assessment of genetic stability and quantitative monitoring of genetic changes in other RNA viruses of clinical interest. PMID:11593021

  20. Quantitative recurrence for free semigroup actions

    NASA Astrophysics Data System (ADS)

    Carvalho, Maria; Rodrigues, Fagner B.; Varandas, Paulo

    2018-03-01

    We consider finitely generated free semigroup actions on a compact metric space and obtain quantitative information on Poincaré recurrence, average first return time and hitting frequency for the random orbits induced by the semigroup action. Besides, we relate the recurrence to balls with the rates of expansion of the semigroup generators and the topological entropy of the semigroup action. Finally, we establish a partial variational principle and prove an ergodic optimization for this kind of dynamical action. MC has been financially supported by CMUP (UID/MAT/00144/2013), which is funded by FCT (Portugal) with national (MEC) and European structural funds (FEDER) under the partnership agreement PT2020. FR and PV were partially supported by BREUDS. PV has also benefited from a fellowship awarded by CNPq-Brazil and is grateful to the Faculty of Sciences of the University of Porto for the excellent research conditions.

  1. BiQ Analyzer HT: locus-specific analysis of DNA methylation by high-throughput bisulfite sequencing

    PubMed Central

    Lutsik, Pavlo; Feuerbach, Lars; Arand, Julia; Lengauer, Thomas; Walter, Jörn; Bock, Christoph

    2011-01-01

    Bisulfite sequencing is a widely used method for measuring DNA methylation in eukaryotic genomes. The assay provides single-base pair resolution and, given sufficient sequencing depth, its quantitative accuracy is excellent. High-throughput sequencing of bisulfite-converted DNA can be applied either genome wide or targeted to a defined set of genomic loci (e.g. using locus-specific PCR primers or DNA capture probes). Here, we describe BiQ Analyzer HT (http://biq-analyzer-ht.bioinf.mpi-inf.mpg.de/), a user-friendly software tool that supports locus-specific analysis and visualization of high-throughput bisulfite sequencing data. The software facilitates the shift from time-consuming clonal bisulfite sequencing to the more quantitative and cost-efficient use of high-throughput sequencing for studying locus-specific DNA methylation patterns. In addition, it is useful for locus-specific visualization of genome-wide bisulfite sequencing data. PMID:21565797

  2. Dixon quantitative chemical shift MRI for bone marrow evaluation in the lumbar spine: a reproducibility study in healthy volunteers.

    PubMed

    Maas, M; Akkerman, E M; Venema, H W; Stoker, J; Den Heeten, G J

    2001-01-01

    The purpose of this work was to explore the reproducibility of fat-fraction measurements using Dixon quantitative chemical shift imaging (QCSI) in the lumbar spine (L3, L4, and L5) of healthy volunteers. Sixteen healthy volunteers were examined at 1.5 T two times to obtain a repeated measurement in the same slice and a third time in three parallel slices. Single slice, two point Dixon SE (TR/TE 2,500/22.3) sequences were used, from which fat-fraction images were calculated. The fat-fraction results are presented as averages over regions of interest, which were derived from the contours of the vertebrae. Reproducibility measures related to repeated measurements on different days, slice position, and contour drawing were calculated. The mean fat fraction was 0.37 (SD 0.08). The SD due to repeated measurement was small (sigmaR = 0.013-0.032), almost all of which can be explained by slice-(re)-positioning errors. When used to evaluate the same person longitudinally in time, Dixon QCSI fat-fraction measurement has an excellent reproducibility. It is a powerful noninvasive tool in the evaluation of bone marrow composition.

  3. An effective approach to quantitative analysis of ternary amino acids in foxtail millet substrate based on terahertz spectroscopy.

    PubMed

    Lu, Shao Hua; Li, Bao Qiong; Zhai, Hong Lin; Zhang, Xin; Zhang, Zhuo Yong

    2018-04-25

    Terahertz time-domain spectroscopy has been applied to many fields, however, it still encounters drawbacks in multicomponent mixtures analysis due to serious spectral overlapping. Here, an effective approach to quantitative analysis was proposed, and applied on the determination of the ternary amino acids in foxtail millet substrate. Utilizing three parameters derived from the THz-TDS, the images were constructed and the Tchebichef image moments were used to extract the information of target components. Then the quantitative models were obtained by stepwise regression. The correlation coefficients of leave-one-out cross-validation (R loo-cv 2 ) were more than 0.9595. As for external test set, the predictive correlation coefficients (R p 2 ) were more than 0.8026 and the root mean square error of prediction (RMSE p ) were less than 1.2601. Compared with the traditional methods (PLS and N-PLS methods), our approach is more accurate, robust and reliable, and can be a potential excellent approach to quantify multicomponent with THz-TDS spectroscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Quantitative thermodynamic predication of interactions between nucleic acid and non-nucleic acid species using Microsoft excel.

    PubMed

    Zou, Jiaqi; Li, Na

    2013-09-01

    Proper design of nucleic acid sequences is crucial for many applications. We have previously established a thermodynamics-based quantitative model to help design aptamer-based nucleic acid probes by predicting equilibrium concentrations of all interacting species. To facilitate customization of this thermodynamic model for different applications, here we present a generic and easy-to-use platform to implement the algorithm of the model with Microsoft(®) Excel formulas and VBA (Visual Basic for Applications) macros. Two Excel spreadsheets have been developed: one for the applications involving only nucleic acid species, the other for the applications involving both nucleic acid and non-nucleic acid species. The spreadsheets take the nucleic acid sequences and the initial concentrations of all species as input, guide the user to retrieve the necessary thermodynamic constants, and finally calculate equilibrium concentrations for all species in various bound and unbound conformations. The validity of both spreadsheets has been verified by comparing the modeling results with the experimental results on nucleic acid sequences reported in the literature. This Excel-based platform described here will allow biomedical researchers to rationalize the sequence design of nucleic acid probes using the thermodynamics-based modeling even without relevant theoretical and computational skills. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  5. A Colorimetric Analysis Experiment Not Requiring a Spectrophotometer: Quantitative Determination of Albumin in Powdered Egg White

    ERIC Educational Resources Information Center

    Charlton, Amanda K.; Sevcik, Richard S.; Tucker, Dorie A.; Schultz, Linda D.

    2007-01-01

    A general science experiment for high school chemistry students might serve as an excellent review of the concepts of solution preparation, solubility, pH, and qualitative and quantitative analysis of a common food product. The students could learn to use safe laboratory techniques, collect and analyze data using proper scientific methodology and…

  6. Selection and validation of reference genes for quantitative real-time PCR in Artemisia sphaerocephala based on transcriptome sequence data.

    PubMed

    Hu, Xiaowei; Zhang, Lijing; Nan, Shuzhen; Miao, Xiumei; Yang, Pengfang; Duan, Guoqin; Fu, Hua

    2018-05-30

    Artemisia sphaerocephala, a dicotyledonous perennial semi-shrub belonging to the Artemisia genus of the Compositae family, is widely distributed in northwestern China. This shrub is one of the most important pioneer plants which is capable of protecting rangelands from wind erosion. It therefore plays a vital role in maintaining desert ecosystem stability. In addition, to its use as a forage grass, it has excellent prospective applications as a source of plant oil and as a plant-based fuel. The use of internal genes is the basis for accurately assessing Real time quantitative PCR. In this study, based on transcriptome data of A. sphaerocephala, we analyzed 21 candidate internal genes to determine the optimal internal genes in this shrub. The stabilities of candidate genes were evaluated in 16 samples of A. sphaerocephala. Finally, UBC9 and TIP41-like were determined as the optimal reference genes in A. sphaerocephala by Delta Ct and three various programs. There were GeNorm, NormFinder and BestKeeper. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Rapid detection of porcine circovirus type 2 using a TaqMan-based real-time PCR.

    PubMed

    Zhao, Kai; Han, Fangting; Zou, Yong; Zhu, Lianlong; Li, Chunhua; Xu, Yan; Zhang, Chunling; Tan, Furong; Wang, Jinbin; Tao, Shiru; He, Xizhong; Zhou, Zongqing; Tang, Xueming

    2010-12-31

    Porcine circovirus type 2 (PCV2) and the associated disease postweaning multisystemic wasting syndrome (PMWS) have caused heavy losses in global agriculture in recent decades. Rapid detection of PCV2 is very important for the effective prophylaxis and treatment of PMWS. To establish a sensitive, specific assay for the detection and quantitation of PCV2, we designed and synthesized specific primers and a probe in the open reading frame 2. The assay had a wide dynamic range with excellent linearity and reliable reproducibility, and detected between 102 and 1010 copies of the genomic DNA per reaction. The coefficient of variation for Ct values varied from 0.59% to 1.05% in the same assay and from 1.9% to 4.2% in 10 different assays. The assay did not cross-react with porcine circovirus type 1, porcine reproductive and respiratory, porcine epidemic diarrhea, transmissible gastroenteritis of pigs and rotavirus. The limits of detection and quantitation were 10 and 100 copies, respectively. Using the established real-time PCR system, 39 of the 40 samples we tested were detected as positive.

  8. Measurement fidelity of heart rate variability signal processing: The devil is in the details

    PubMed Central

    Jarrin, Denise C.; McGrath, Jennifer J.; Giovanniello, Sabrina; Poirier, Paul; Lambert, Marie

    2017-01-01

    Heart rate variability (HRV) is a particularly valuable quantitative marker of the flexibility and balance of the autonomic nervous system. Significant advances in software programs to automatically derive HRV have led to its extensive use in psychophysiological research. However, there is a lack of systematic comparisons across software programs used to derive HRV indices. Further, researchers report meager details on important signal processing decisions making synthesis across studies challenging. The aim of the present study was to evaluate the measurement fidelity of time- and frequency-domain HRV indices derived from three predominant signal processing software programs commonly used in clinical and research settings. Triplicate ECG recordings were derived from 20 participants using identical data acquisition hardware. Among the time-domain indices, there was strong to excellent correspondence (ICCavg =0.93) for SDNN, SDANN, SDNNi, rMSSD, and pNN50. The frequency-domain indices yielded excellent correspondence (ICCavg =0.91) for LF, HF, and LF/HF ratio, except for VLF which exhibited poor correspondence (ICCavg =0.19). Stringent user-decisions and technical specifications for nuanced HRV processing details are essential to ensure measurement fidelity across signal processing software programs. PMID:22820268

  9. Fatty degeneration of the rotator cuff muscles on pre- and postoperative CT arthrography (CTA): is the Goutallier grading system reliable?

    PubMed

    Lee, Eugene; Choi, Jung-Ah; Oh, Joo Han; Ahn, Soyeon; Hong, Sung Hwan; Chai, Jee Won; Kang, Heung Sik

    2013-09-01

    To retrospectively evaluate fatty degeneration (FD) of rotator cuff muscles on CTA using Goutallier's grading system and quantitative measurements with comparison between pre- and postoperative states. IRB approval was obtained for this study. Two radiologists independently reviewed pre- and postoperative CTAs of 43 patients (24 males and 19 females, mean age, 58.1 years) with 46 shoulders confirmed as full-thickness tears with random distribution. FD of supraspinatus, infraspinatus/teres minor, and subscapularis was assessed using Goutallier's system and by quantitative measurements of Hounsfield units (HUs) on sagittal images. Changes in FD grades and HUs were compared between pre- and postoperative CTAs and analyzed with respect to preoperative tear size and postoperative cuff integrity. The correlations between qualitative grades and quantitative measurements and their inter-observer reliabilities were also assessed. There was statistically significant correlation between FD grades and HU measurements of all muscles on pre- and postoperative CTA (p < 0.05). Inter-observer reliability of fatty degeneration grades were excellent to substantial on both pre- and postoperative CTA in supraspinatus (0.8685 and 0.8535) and subscapularis muscles (0.7777 and 0.7972), but fair in infraspinatus/teres minor muscles (0.5791 and 0.5740); however, quantitative Hounsfield units measurements showed excellent reliability for all muscles (ICC: 0.7950 and 0.9346 for SST, 0.7922 and 0.8492 for SSC, and 0.9254 and 0.9052 for IST/TM). No muscle showed improvement of fatty degeneration after surgical repair on qualitative and quantitative assessments; there was no difference in changes of fatty degeneration after surgical repair according to preoperative tear size and post-operative cuff integrity (p > 0.05). The average dose-length product (DLP, mGy · cm) was 365.2 mGy · cm (range, 323.8-417.2 mGy · cm) and estimated average effective dose was 5.1 mSv. Goutallier grades correlated well with HUs of rotator cuff muscles. Reliability was excellent for both systems, except for FD grade of IST/TM muscles, which may be more reliably assessed using quantitative measurements.

  10. The Role of Introductory Geosciences in Students' Quantitative Literacy

    NASA Astrophysics Data System (ADS)

    Wenner, J. M.; Manduca, C.; Baer, E. M.

    2006-12-01

    Quantitative literacy is more than mathematics; it is about reasoning with data. Colleges and universities have begun to recognize the distinction between mathematics and quantitative literacy, modifying curricula to reflect the need for numerate citizens. Although students may view geology as 'rocks for jocks', the geosciences are truthfully rife with data, making introductory geoscience topics excellent context for developing the quantitative literacy of students with diverse backgrounds. In addition, many news items that deal with quantitative skills, such as the global warming phenomenon, have their basis in the Earth sciences and can serve as timely examples of the importance of quantitative literacy for all students in introductory geology classrooms. Participants at a workshop held in 2006, 'Infusing Quantitative Literacy into Introductory Geoscience Courses,' discussed and explored the challenges and opportunities associated with the inclusion of quantitative material and brainstormed about effective practices for imparting quantitative literacy to students with diverse backgrounds. The tangible results of this workshop add to the growing collection of quantitative materials available through the DLESE- and NSF-supported Teaching Quantitative Skills in the Geosciences website, housed at SERC. There, faculty can find a collection of pages devoted to the successful incorporation of quantitative literacy in introductory geoscience. The resources on the website are designed to help faculty to increase their comfort with presenting quantitative ideas to students with diverse mathematical abilities. A methods section on "Teaching Quantitative Literacy" (http://serc.carleton.edu/quantskills/methods/quantlit/index.html) focuses on connecting quantitative concepts with geoscience context and provides tips, trouble-shooting advice and examples of quantitative activities. The goal in this section is to provide faculty with material that can be readily incorporated into existing introductory geoscience courses. In addition, participants at the workshop (http://serc.carleton.edu/quantskills/workshop06/index.html) submitted and modified more than 20 activities and model courses (with syllabi) designed to use best practices for helping introductory geoscience students to become quantitatively literate. We present insights from the workshop and other sources for a framework that can aid in increasing quantitative literacy of students from a variety of backgrounds in the introductory geoscience classroom.

  11. VIBA-Lab 3.0: Computer program for simulation and semi-quantitative analysis of PIXE and RBS spectra and 2D elemental maps

    NASA Astrophysics Data System (ADS)

    Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana

    2015-11-01

    VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster-Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By "running" a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.

  12. Fluid Transient Analysis during Priming of Evacuated Line

    NASA Technical Reports Server (NTRS)

    Bandyopadhyay, Alak; Majumdar, Alok K.; Holt, Kimberley

    2017-01-01

    Water hammer analysis in pipe lines, in particularly during priming into evacuated lines is important for the design of spacecraft and other in-space application. In the current study, a finite volume network flow analysis code is used for modeling three different geometrical configurations: the first two being straight pipe, one with atmospheric air and other with evacuated line, and the third case is a representation of a complex flow network system. The numerical results show very good agreement qualitatively and quantitatively with measured data available in the literature. The peak pressure and impact time in case of straight pipe priming in evacuated line shows excellent agreement.

  13. Thin-film hermeticity - A quantitative analysis of diamondlike carbon using variable angle spectroscopic ellipsometry

    NASA Technical Reports Server (NTRS)

    Orzeszko, S.; De, Bhola N.; Woollam, John A.; Pouch, John J.; Alterovitz, Samuel A.

    1988-01-01

    This paper reports on the successful application of variable-angle spectroscopic ellipsometry to quantitative thin-film hermeticity evaluation. It is shown that, under a variety of film preparations and moisture introduction conditions, water penetrates only a very thin diamondlike carbon (DLC) top surface-roughness region. Thus, DLC is an excellent candidate for use as protective coatings in adverse chemical and aqueous environments.

  14. A sandwich-type optical immunosensor based on the alkaline phosphatase enzyme for Salmonella thypimurium detection

    NASA Astrophysics Data System (ADS)

    Widyastuti, E.; Puspitasari Schonherr, M. F.; Masruroh, A.; Anggraeni, R. A.; Nisak, Y. K.; Mursidah, S.

    2018-03-01

    Salmonella is pathogenic bacteria that caused foodborne diseases which being called Salmonellosis. Prevalence of Salmonellosis that being caused by Salmonella thypimurium in Indonesia is quite high. However, detection of Salmonella bacteria in food still limited, complicated, and required a lot time. Sensitive optical assay for Salmonella thypimurium paper based detection has been developed by integrating sandwich assay between antibody-antigen complex and alkaline phosphatase enzyme that produce visible bluish-purple colour with presence of NBT-BCIP substrate. The results showed that Limit of Quantitation of detection is 105 CFU mL-1 with detection time 15 minutes. Linearity test between Colour intensity that produced from Salmonella concentration presence on samples showed that detection has good linearity. Selectivity test exhibited excellent sensitivity with good discrimination against Escherichia coli.

  15. Cost-Effective Experiments on the Diffraction and Interference of Light.

    ERIC Educational Resources Information Center

    Sprigham, S. V.

    2000-01-01

    Presents an alternative experimental arrangement that results in a considerable cost savings by reducing the number of sensors and other apparati required while giving excellent quantitative results for comparison with theory. (Author/CCM)

  16. Push-through Direction Injectin NMR Automation

    EPA Science Inventory

    Nuclear magnetic resonance (NMR) and mass spectrometry (MS) are the two major spectroscopic techniques successfully used in metabolomics studies. The non-invasive, quantitative and reproducible characteristics make NMR spectroscopy an excellent technique for detection of endogeno...

  17. Principles and applications of polymerase chain reaction in medical diagnostic fields: a review

    PubMed Central

    Valones, Marcela Agne Alves; Guimarães, Rafael Lima; Brandão, Lucas André Cavalcanti; de Souza, Paulo Roberto Eleutério; de Albuquerque Tavares Carvalho, Alessandra; Crovela, Sergio

    2009-01-01

    Recent developments in molecular methods have revolutionized the detection and characterization of microorganisms in a broad range of medical diagnostic fields, including virology, mycology, parasitology, microbiology and dentistry. Among these methods, Polymerase Chain Reaction (PCR) has generated great benefits and allowed scientific advancements. PCR is an excellent technique for the rapid detection of pathogens, including those difficult to culture. Along with conventional PCR techniques, Real-Time PCR has emerged as a technological innovation and is playing an ever-increasing role in clinical diagnostics and research laboratories. Due to its capacity to generate both qualitative and quantitative results, Real-Time PCR is considered a fast and accurate platform. The aim of the present literature review is to explore the clinical usefulness and potential of both conventional PCR and Real-Time PCR assays in diverse medical fields, addressing its main uses and advances. PMID:24031310

  18. Second Harmonic Generation Guided Raman Spectroscopy for Sensitive Detection of Polymorph Transitions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhury, Azhad U.; Ye, Dong Hye; Song, Zhengtian

    Second harmonic generation (SHG) was integrated with Raman spectroscopy for the analysis of pharmaceutical materials. Particulate formulations of clopidogrel bisulfate were prepared in two crystal forms (Form I and Form II). Image analysis approaches enable automated identification of particles by bright field imaging, followed by classification by SHG. Quantitative SHG microscopy enabled discrimination of crystal form on a per particle basis with 99.95% confidence in a total measurement time of ~10 ms per particle. Complementary measurements by Raman and synchrotron XRD are in excellent agreement with the classifications made by SHG, with measurement times of ~1 min and several secondsmore » per particle, respectively. Coupling these capabilities with at-line monitoring may enable real-time feedback for reaction monitoring during pharmaceutical production to favor the more bioavailable but metastable Form I with limits of detection in the ppm regime.« less

  19. Diagnostic accuracy of quantitative real-time PCR assay versus clinical and Gram stain identification of bacterial vaginosis.

    PubMed

    Menard, J-P; Mazouni, C; Fenollar, F; Raoult, D; Boubli, L; Bretelle, F

    2010-12-01

    The purpose of this investigation was to determine the diagnostic accuracy of quantitative real-time polymerase chain reaction (PCR) assay in diagnosing bacterial vaginosis versus the standard methods, the Amsel criteria and the Nugent score. The Amsel criteria, the Nugent score, and results from the molecular tool were obtained independently from vaginal samples of 163 pregnant women who reported abnormal vaginal symptoms before 20 weeks gestation. To determine the performance of the molecular tool, we calculated the kappa value, sensitivity, specificity, and positive and negative predictive values. Either or both of the Amsel criteria (≥3 criteria) and the Nugent score (score ≥7) indicated that 25 women (15%) had bacterial vaginosis, and the remaining 138 women did not. DNA levels of Gardnerella vaginalis or Atopobium vaginae exceeded 10(9) copies/mL or 10(8) copies/mL, respectively, in 34 (21%) of the 163 samples. Complete agreement between both reference methods and high concentrations of G. vaginalis and A. vaginae was found in 94.5% of women (154/163 samples, kappa value = 0.81, 95% confidence interval 0.70-0.81). The nine samples with discordant results were categorized as intermediate flora by the Nugent score. The molecular tool predicted bacterial vaginosis with a sensitivity of 100%, a specificity of 93%, a positive predictive value of 73%, and a negative predictive value of 100%. The quantitative real-time PCR assay shows excellent agreement with the results of both reference methods for the diagnosis of bacterial vaginosis.

  20. Validation and application of a quantitative real-time PCR assay to detect common wheat adulteration of durum wheat for pasta production.

    PubMed

    Carloni, Elisa; Amagliani, Giulia; Omiccioli, Enrica; Ceppetelli, Veronica; Del Mastro, Michele; Rotundo, Luca; Brandi, Giorgio; Magnani, Mauro

    2017-06-01

    Pasta is the Italian product par excellence and it is now popular worldwide. Pasta of a superior quality is made with pure durum wheat. In Italy, addition of Triticum aestivum (common wheat) during manufacturing is not allowed and, without adequate labeling, its presence is considered an adulteration. PCR-related techniques can be employed for the detection of common wheat contaminations. In this work, we demonstrated that a previously published method for the detection of T. aestivum, based on the gliadin gene, is inadequate. Moreover, a new molecular method, based on DNA extraction from semolina and real-time PCR determination of T. aestivum in Triticum spp., was validated. This multiplex real-time PCR, based on the dual-labeled probe strategy, guarantees target detection specificity and sensitivity in a short period of time. Moreover, the molecular analysis of common wheat contamination in commercial wheat and flours is described for the first time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a causemore » for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA.« less

  2. FACTORS AFFECTING THE UPTAKE OF LISSAMINE GREEN BY SERUM PROTEINS

    PubMed Central

    Brackenridge, C. J.

    1960-01-01

    Eight physicochemical factors which affect the uptake of lissamine green on filter paper impregnated with serum proteins have been examined, and their relevance to the staining of electrophoretically separated protein fractions is discussed. It is shown that grade of paper, weight of protein applied, separate and combined denaturation and staining time, temperature and concentration of staining solution, concentration of denaturant, and type of protein all influence the weight of dye absorbed per unit weight of applied protein, and must be rigidly standardized if valid quantitative results are to be obtained. Five sets of conditions are obtained for optimal staining and it is found that separation of denaturant from dye yields the best procedure. It is concluded that lissamine green is an excellent dye for the staining and quantitative estimation of separated protein fractions in paper electrophoresis, and that conditions can usually be arranged to produce a linear relation between dye uptake and protein concentration in an experimentally efficient manner. PMID:13803681

  3. Quantitative intact specimen magnetic resonance microscopy at 3.0 T.

    PubMed

    Bath, Kevin G; Voss, Henning U; Jing, Deqiang; Anderson, Stewart; Hempstead, Barbara; Lee, Francis S; Dyke, Jonathan P; Ballon, Douglas J

    2009-06-01

    In this report, we discuss the application of a methodology for high-contrast, high-resolution magnetic resonance microscopy (MRM) of murine tissue using a 3.0-T imaging system. We employed a threefold strategy that included customized specimen preparation to maximize image contrast, three-dimensional data acquisition to minimize scan time and custom radiofrequency resonator design to maximize signal sensitivity. Images had a resolution of 100 x 78 x 78 microm(3) with a signal-to-noise ratio per voxel greater than 25:1 and excellent contrast-to-noise ratios over a 30-min acquisition. We quantitatively validated the methods through comparisons of neuroanatomy across two lines of genetically engineered mice. Specifically, we were able to detect volumetric differences of as little as 9% between genetically engineered mouse strains in multiple brain regions that were predictive of underlying impairments in brain development. The overall methodology was straightforward to implement and provides ready access to basic MRM at field strengths that are widely available in both the laboratory and the clinic.

  4. Interdisciplinary ICU Cardiac Arrest Debriefing Improves Survival Outcomes

    PubMed Central

    Wolfe, Heather; Zebuhr, Carleen; Topjian, Alexis A.; Nishisaki, Akira; Niles, Dana E.; Meaney, Peter A.; Boyle, Lori; Giordano, Rita T.; Davis, Daniela; Priestley, Margaret; Apkon, Michael; Berg, Robert A.; Nadkarni, Vinay M.; Sutton, Robert M.

    2014-01-01

    Objective In-hospital cardiac arrest is an important public health problem. High-quality resuscitation improves survival but is difficult to achieve. Our objective is to evaluate the effectiveness of a novel, interdisciplinary, postevent quantitative debriefing program to improve survival outcomes after in-hospital pediatric chest compression events. Design, Setting, and Patients Single-center prospective interventional study of children who received chest compressions between December 2008 and June 2012 in the ICU. Interventions Structured, quantitative, audiovisual, interdisciplinary debriefing of chest compression events with front-line providers. Measurements and Main Results Primary outcome was survival to hospital discharge. Secondary outcomes included survival of event (return of spontaneous circulation for ≥ 20 min) and favorable neurologic outcome. Primary resuscitation quality outcome was a composite variable, termed “excellent cardiopulmonary resuscitation,” prospectively defined as a chest compression depth ≥ 38 mm, rate ≥ 100/min, ≤ 10% of chest compressions with leaning, and a chest compression fraction > 90% during a given 30-second epoch. Quantitative data were available only for patients who are 8 years old or older. There were 119 chest compression events (60 control and 59 interventional). The intervention was associated with a trend toward improved survival to hospital discharge on both univariate analysis (52% vs 33%, p = 0.054) and after controlling for confounders (adjusted odds ratio, 2.5; 95% CI, 0.91–6.8; p = 0.075), and it significantly increased survival with favorable neurologic outcome on both univariate (50% vs 29%, p = 0.036) and multivariable analyses (adjusted odds ratio, 2.75; 95% CI, 1.01–7.5; p = 0.047). Cardiopulmonary resuscitation epochs for patients who are 8 years old or older during the debriefing period were 5.6 times more likely to meet targets of excellent cardiopulmonary resuscitation (95% CI, 2.9–10.6; p < 0.01). Conclusion Implementation of an interdisciplinary, postevent quantitative debriefing program was significantly associated with improved cardiopulmonary resuscitation quality and survival with favorable neurologic outcome. (Crit Care Med 2014; XX:00–00) PMID:24717462

  5. Simultaneous X-ray fluorescence and scanning X-ray diffraction microscopy at the Australian Synchrotron XFM beamline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Michael W. M.; Phillips, Nicholas W.; van Riessen, Grant A.

    2016-08-11

    Owing to its extreme sensitivity, quantitative mapping of elemental distributionsviaX-ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X-ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super-resolved ultra-structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step- and fly-scanning modes, robust, simultaneous XFM-SXDM is demonstrated.

  6. Healthcare waste management: qualitative and quantitative appraisal of nurses in a tertiary care hospital of India.

    PubMed

    Shivalli, Siddharudha; Sanklapur, Vasudha

    2014-01-01

    The nurse's role in healthcare waste management is crucial. (1) To appraise nurses quantitatively and qualitatively regarding healthcare waste management; (2) to elicit the determinants of knowledge and attitudes of healthcare waste management. A cross-sectional study was undertaken at a tertiary care hospital of Mangalore, India. Self-administered pretested questionnaire and "nonparticipatory observation" were used for quantitative and qualitative appraisals. Percentage knowledge score was calculated based on their total knowledge score. Nurses' knowledge was categorized as excellent (>70%), good (50-70%), and poor (<50%). Chi square test was applied to judge the association of study variables with their attitudes and knowledge. Out of 100 nurses 47 had excellent knowledge (>70% score). Most (86%) expressed the need of refresher training. No study variable displayed significant association (P > 0.05) with knowledge. Apt segregation practices were followed except in casualty. Patients and entourages misinterpreted the colored containers. Nurses' knowledge and healthcare waste management practices were not satisfactory. There is a need of refresher trainings at optimum intervals to ensure sustainability and further improvement. Educating patients and their entourages and display of segregation information board in local language are recommended.

  7. Static headspace gas chromatographic method for quantitative determination of residual solvents in pharmaceutical drug substances according to european pharmacopoeia requirements.

    PubMed

    Otero, Raquel; Carrera, Guillem; Dulsat, Joan Francesc; Fábregas, José Luís; Claramunt, Juan

    2004-11-19

    A static headspace (HS) gas chromatographic method for quantitative determination of residual solvents in a drug substance has been developed according to European Pharmacopoeia general procedure. A water-dimethylformamide mixture is proposed as sample solvent to obtain good sensitivity and recovery. The standard addition technique with internal standard quantitation was used for ethanol, tetrahydrofuran and toluene determination. Validation was performed within the requirements of ICH validation guidelines Q2A and Q2B. Selectivity was tested for 36 solvents, and system suitability requirements described in the European Pharmacopoeia were checked. Limits of detection and quantitation, precision, linearity, accuracy, intermediate precision and robustness were determined, and excellent results were obtained.

  8. Integrated Platform for Expedited Synthesis–Purification–Testing of Small Molecule Libraries

    PubMed Central

    2017-01-01

    The productivity of medicinal chemistry programs can be significantly increased through the introduction of automation, leading to shortened discovery cycle times. Herein, we describe a platform that consolidates synthesis, purification, quantitation, dissolution, and testing of small molecule libraries. The system was validated through the synthesis and testing of two libraries of binders of polycomb protein EED, and excellent correlation of obtained data with results generated through conventional approaches was observed. The fully automated and integrated platform enables batch-supported compound synthesis based on a broad array of chemical transformations with testing in a variety of biochemical assay formats. A library turnaround time of between 24 and 36 h was achieved, and notably, each library synthesis produces sufficient amounts of compounds for further evaluation in secondary assays thereby contributing significantly to the shortening of medicinal chemistry discovery cycles. PMID:28435537

  9. Stochasticity in the signalling network of a model microbe

    NASA Astrophysics Data System (ADS)

    Bischofs, Ilka; Foley, Jonathan; Battenberg, Eric; Fontaine-Bodin, Lisa; Price, Gavin; Wolf, Denise; Arkin, Adam

    2007-03-01

    The soil dwelling bacterium Bacillus subtilis is an excellent model organism for studying stochastic stress response induction in an isoclonal population. Subjected to the same stressor cells undergo different cell fates, including sporulation, competence, degradative enzyme synthesis and motility. For example, under conditions of nutrient deprivation and high cell density only a portion of the cell population forms an endospore. Here we use a combined experimental and theoretical approach to study stochastic sporulation induction in Bacillus subtilis. Using several fluorescent reporter strains we apply time lapse fluorescent microscopy in combination with quantitative image analysis to study cell fate progression on a single cell basis and elucidate key noise generators in the underlying cellular network.

  10. Extraction and LC determination of lysine clonixinate salt in water/oil microemulsions.

    PubMed

    Pineros, I; Ballesteros, P; Lastres, J L

    2002-02-01

    A new reversed-phase high performance liquid chromatography method has been developed and validated for the quantitative determination of lysine clonixinate salt in water/oil microemulsions. The mobile phase was acetonitrile-buffer phosphate pH 3.3. Detection was UV absorbance at 252 nm. The precision and accurately of the method were excellent. The established linearity range was 5-60 microg ml(-1) (r(2)=0.999). Microemulsions samples were dispersed with chloroform and extracted lysine clonixinate salt with water. This easy method employing chloroformic extraction has been done three times. The recovery of lysine clonixinate salt from spiked placebo and microemulsion were >90% over the linear range.

  11. Evaluation of macrocyclic hydroxyisophthalamide ligands as chelators for zirconium-89

    PubMed Central

    Xu, Jide; Tatum, David; Magda, Darren

    2017-01-01

    The development of bifunctional chelators (BFCs) for zirconium-89 immuno-PET applications is an area of active research. Herein we report the synthesis and evaluation of octadentate hydroxyisophthalamide ligands (1 and 2) as zirconium-89 chelators. While both radiometal complexes could be prepared quantitatively and with excellent specific activity, preparation of 89Zr-1 required elevated temperature and an increased reaction time. 89Zr-1 was more stable than 89Zr-2 when challenged in vitro by excess DTPA or serum proteins and in vivo during acute biodistribution studies. Differences in radiometal complex stability arise from structural changes between the two ligand systems, and suggest further ligand optimization is necessary to enhance 89Zr chelation. PMID:28575044

  12. Evaluation of macrocyclic hydroxyisophthalamide ligands as chelators for zirconium-89.

    PubMed

    Bhatt, Nikunj B; Pandya, Darpan N; Xu, Jide; Tatum, David; Magda, Darren; Wadas, Thaddeus J

    2017-01-01

    The development of bifunctional chelators (BFCs) for zirconium-89 immuno-PET applications is an area of active research. Herein we report the synthesis and evaluation of octadentate hydroxyisophthalamide ligands (1 and 2) as zirconium-89 chelators. While both radiometal complexes could be prepared quantitatively and with excellent specific activity, preparation of 89Zr-1 required elevated temperature and an increased reaction time. 89Zr-1 was more stable than 89Zr-2 when challenged in vitro by excess DTPA or serum proteins and in vivo during acute biodistribution studies. Differences in radiometal complex stability arise from structural changes between the two ligand systems, and suggest further ligand optimization is necessary to enhance 89Zr chelation.

  13. A CZT-based blood counter for quantitative molecular imaging.

    PubMed

    Espagnet, Romain; Frezza, Andrea; Martin, Jean-Pierre; Hamel, Louis-André; Lechippey, Laëtitia; Beauregard, Jean-Mathieu; Després, Philippe

    2017-12-01

    Robust quantitative analysis in positron emission tomography (PET) and in single-photon emission computed tomography (SPECT) typically requires the time-activity curve as an input function for the pharmacokinetic modeling of tracer uptake. For this purpose, a new automated tool for the determination of blood activity as a function of time is presented. The device, compact enough to be used on the patient bed, relies on a peristaltic pump for continuous blood withdrawal at user-defined rates. Gamma detection is based on a 20 × 20 × 15 mm 3 cadmium zinc telluride (CZT) detector, read by custom-made electronics and a field-programmable gate array-based signal processing unit. A graphical user interface (GUI) allows users to select parameters and easily perform acquisitions. This paper presents the overall design of the device as well as the results related to the detector performance in terms of stability, sensitivity and energy resolution. Results from a patient study are also reported. The device achieved a sensitivity of 7.1 cps/(kBq/mL) and a minimum detectable activity of 2.5 kBq/ml for 18 F. The gamma counter also demonstrated an excellent stability with a deviation in count rates inferior to 0.05% over 6 h. An energy resolution of 8% was achieved at 662 keV. The patient study was conclusive and demonstrated that the compact gamma blood counter developed has the sensitivity and the stability required to conduct quantitative molecular imaging studies in PET and SPECT.

  14. Analytical model of rotor wake aerodynamics in ground effect

    NASA Technical Reports Server (NTRS)

    Saberi, H. A.

    1983-01-01

    The model and the computer program developed provides the velocity, location, and circulation of the tip vortices of a two-blade helicopter in and out of the ground effect. Comparison of the theoretical results with some experimental measurements for the location of the wake indicate that there is excellent accuracy in the vicinity of the rotor and fair amount of accuracy far from it. Having the location of the wake at all times enables us to compute the history of the velocity and the location of any point in the flow. The main goal of out study, induced velocity at the rotor, can also be calculated in addition to stream lines and streak lines. Since the wake location close to the rotor is known more accurately than at other places, the calculated induced velocity over the disc should be a good estimate of the real induced velocity, with the exception of the blade location, because each blade was replaced only by a vortex line. Because no experimental measurements of the wake close to the ground were available to us, quantitative evaluation of the theoretical wake was not possible. But qualitatively we have been able to show excellent agreement. Comparison of flow visualization with out results has indicated the location of the ground vortex is estimated excellently. Also the flow field in hover is well represented.

  15. Comparative evaluation of a laboratory developed real-time PCR assay and the RealStar® HHV-6 PCR Kit for quantitative detection of human herpesvirus 6.

    PubMed

    Yip, Cyril C Y; Sridhar, Siddharth; Cheng, Andrew K W; Fung, Ami M Y; Cheng, Vincent C C; Chan, Kwok-Hung; Yuen, Kwok-Yung

    2017-08-01

    HHV-6 reactivation in immunocompromised patients is common and may be associated with serious morbidity and mortality; therefore, early detection and initiation of therapy might be of benefit. Real-time PCR assays allow for early identification of HHV-6 reactivation to assist in providing a timely response. Thus, we compared the performance of an in-house developed HHV-6 quantitative PCR assay with a commercially available kit, the RealStar ® HHV-6 PCR Kit. The analytical sensitivity, analytical specificity, linearity, precision and accuracy of the in-house developed HHV-6 qPCR assay were evaluated. The diagnostic performance of the in-house HHV-6 qPCR assay was compared with the RealStar ® HHV-6 PCR Kit, using 72 clinical specimens and 17 proficiency testing samples. Linear regression analysis of the quantitative results showed a dynamic range from 2 to 10 log 10 copies/ml and a coefficient of determination (R 2 ) of 0.999 for the in-house assay. A dilution series demonstrated a limit of detection and a limit of quantification of 1.7 log 10 and 2 log 10 copies/ml, respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.27% to 4.37%. A comparison of 27 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house HHV-6 qPCR assay and the RealStar ® HHV-6 PCR Kit (R 2 =0.926; P<0.0001), with an average bias of -0.24 log 10 copies/ml. The in-house developed HHV-6 qPCR method is a sensitive and reliable assay with lower cost for the detection and quantification of HHV-6 DNA when compared to the RealStar ® HHV-6 PCR Kit. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: V. Predictive absorbability models.

    PubMed

    Langenbucher, Frieder

    2007-08-01

    This paper discusses Excel applications related to the prediction of drug absorbability from physicochemical constants. PHDISSOC provides a generalized model for pH profiles of electrolytic dissociation, water solubility, and partition coefficient. SKMODEL predicts drug absorbability, based on a log-log plot of water solubility and O/W partitioning; augmented by additional features such as electrolytic dissociation, melting point, and the dose administered. GIABS presents a mechanistic model of g.i. drug absorption. BIODATCO presents a database compiling relevant drug data to be used for quantitative predictions.

  17. Quantitative analysis of ecological effects for land use planning based on ecological footprint method: a case research in Nanyang City

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Liu, Yaolin; Chen, Xinming

    2008-10-01

    The research of coordinated development between land use and ecological building is a new problem with the development of country economy, whose intention is to improve economy development and protect eco-environment in order to realize regional sustainable development. Evaluating human effects on the ecosystem by a comprehensive, scientific and quantitative method is a critical issue in the process of general land use planning. At present, ecological footprint methodology, as an excellent educational tool applicable to global issues, is essential for quantifying humanity's consumption of natural capital, for overall assessments of human impact on earth as well as for general land use planning. However, quantitative studies on the development trends of ecological footprint (EF) time series and biological capacity (BC) time series in a given region are still rare. Taking Nanyang City as a case study, this paper presents two quantitative estimate indices over time scale called the change rate and scissors difference to quantitatively analyze the trends of EF and BC over the planning period in general land use planning form 1997-2004 and to evaluate the ecological effects of the land use general planning form 1997 to.2010. The results showed that: 1 In Nanyang city, trends of the per capita EF and BC were on the way round, and the ecological deficit enhanced from 1997 to 2010. 2 The difference between the two development trends of per capita EF and BC had been increasing rapidly and the conflict between the EF and BC was aggravated from 1997 to 2010. 3 The general land use planning (1997 - 2010) of Nanyang city had produced some positive effects on the local ecosystem, but the expected biological capacity in 2010 can hardly be realized following this trend. Therefore, this paper introduces a "trinity" land use model in the guidelines of environment- friendly land use pattern and based on the actual situation of Nanyang city, with the systemic synthesis of land utilization of the cities, the village and the suburb as a principal part and the land development reorganization and the ecological environment construction as the key point.

  18. Validity and sensitivity to change of the semi-quantitative OMERACT ultrasound scoring system for tenosynovitis in patients with rheumatoid arthritis.

    PubMed

    Ammitzbøll-Danielsen, Mads; Østergaard, Mikkel; Naredo, Esperanza; Terslev, Lene

    2016-12-01

    The aim was to evaluate the metric properties of the semi-quantitative OMERACT US scoring system vs a novel quantitative US scoring system for tenosynovitis, by testing its intra- and inter-reader reliability, sensitivity to change and comparison with clinical tenosynovitis scoring in a 6-month follow-up study. US and clinical assessments of the tendon sheaths of the clinically most affected hand and foot were performed at baseline, 3 and 6 months in 51 patients with RA. Tenosynovitis was assessed using the semi-quantitative scoring system (0-3) proposed by the OMERACT US group and a new quantitative US evaluation (0-100). A sum for US grey scale (GS), colour Doppler (CD) and pixel index (PI), respectively, was calculated for each patient. In 20 patients, intra- and inter-observer agreement was established between two independent investigators. A binary clinical tenosynovitis score was performed, calculating a sum score per patient. The intra- and inter-observer agreements for US tenosynovitis assessments were very good at baseline and for change for GS and CD, but less good for PI. The smallest detectable change was 0.97 for GS, 0.93 for CD and 30.1 for PI. The sensitivity to change from month 0 to 6 was high for GS and CD, and slightly higher than for clinical tenosynovitis score and PI. This study demonstrated an excellent intra- and inter-reader agreement between two investigators for the OMERACT US scoring system for tenosynovitis and a high ability to detect changes over time. Quantitative assessment by PI did not add further information. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. A highly selective and fast-response fluorescent probe based on Cd-MOF for the visual detection of Al3+ ion and quantitative detection of Fe3+ ion

    NASA Astrophysics Data System (ADS)

    Lv, Rui; Chen, Zhihengyu; Fu, Xin; Yang, Boyi; Li, Hui; Su, Jian; Gu, Wen; Liu, Xin

    2018-03-01

    A new luminescent Cd(II)-based metal-organic framework, [Cd(PAM)(4-bpdb)1.5]·DMF (Cd-MOF, PAM = 4,4‧-methylenebis(3-hydroxy-2-naphthalene-carboxylic acid) and 4-bpdb = 1,4-bis(4-pyridyl)-2,3-diaza-1,3-butadiene) was successfully synthesized by solvothermal synthesis method. The Cd-MOF reveals excellent luminescence property which can selectively detect Al3+ and Fe3+ ions among other interfering metal ions. The detection limit is 0.56 μM for Al3+ ion in aqueous solutions, and it is obvious lower than the maximum standard of Al3+ ion in drinking water of 7.41 μM which is defined by the WHO. More importantly, the Cd-MOF shows an obvious luminescent color change from yellow to blue under the UV lamp irradiation at 365 nm with the dropping of Al3+ ion, which can make it apply to the visual detection. And, the detection based on the test paper was explored for the first time. In addition, the Cd-MOF can also be used for quantitative detecting Fe3+ ion, and the LOD for Fe3+ ion can be as low as 0.3 μM which is lower than most reported MOFs. It is worth noting that Fe3+ and Al3+ ions can not interfere with each other. These properties make it become an excellent luminescence sensor for the detection of Al3+ and Fe3+ ions.

  20. Optimal Hotspots of Dynamic Surfaced-Enhanced Raman Spectroscopy for Drugs Quantitative Detection.

    PubMed

    Yan, Xiunan; Li, Pan; Zhou, Binbin; Tang, Xianghu; Li, Xiaoyun; Weng, Shizhuang; Yang, Liangbao; Liu, Jinhuai

    2017-05-02

    Surface-enhanced Raman spectroscopy (SERS) as a powerful qualitative analysis method has been widely applied in many fields. However, SERS for quantitative analysis still suffers from several challenges partially because of the absence of stable and credible analytical strategy. Here, we demonstrate that the optimal hotspots created from dynamic surfaced-enhanced Raman spectroscopy (D-SERS) can be used for quantitative SERS measurements. In situ small-angle X-ray scattering was carried out to in situ real-time monitor the formation of the optimal hotspots, where the optimal hotspots with the most efficient hotspots were generated during the monodisperse Au-sol evaporating process. Importantly, the natural evaporation of Au-sol avoids the nanoparticles instability of salt-induced, and formation of ordered three-dimensional hotspots allows SERS detection with excellent reproducibility. Considering SERS signal variability in the D-SERS process, 4-mercaptopyridine (4-mpy) acted as internal standard to validly correct and improve stability as well as reduce fluctuation of signals. The strongest SERS spectra at the optimal hotspots of D-SERS have been extracted to statistics analysis. By using the SERS signal of 4-mpy as a stable internal calibration standard, the relative SERS intensity of target molecules demonstrated a linear response versus the negative logarithm of concentrations at the point of strongest SERS signals, which illustrates the great potential for quantitative analysis. The public drugs 3,4-methylenedioxymethamphetamine and α-methyltryptamine hydrochloride obtained precise analysis with internal standard D-SERS strategy. As a consequence, one has reason to believe our approach is promising to challenge quantitative problems in conventional SERS analysis.

  1. Evaluation and utilization of preassembled frozen commercial fast real-time qPCR master mixes for detection of cytomegalovirus and BK virus.

    PubMed

    Glover, William A; Atienza, Ederlyn E; Nesbitt, Shannon; Kim, Woo J; Castor, Jared; Cook, Linda; Jerome, Keith R

    2016-01-01

    Quantitative DNA detection of cytomegalovirus (CMV) and BK virus (BKV) is critical in the management of transplant patients. Quantitative laboratory-developed procedures for CMV and BKV have been described in which much of the processing is automated, resulting in rapid, reproducible, and high-throughput testing of transplant patients. To increase the efficiency of such assays, the performance and stability of four commercial preassembled frozen fast qPCR master mixes (Roche FastStart Universal Probe Master Mix with Rox, Bio-Rad SsoFast Probes Supermix with Rox, Life Technologies TaqMan FastAdvanced Master Mix, and Life Technologies Fast Universal PCR Master Mix), in combination with in-house designed primers and probes, was evaluated using controls and standards from standard CMV and BK assays. A subsequent parallel evaluation using patient samples was performed comparing the performance of freshly prepared assay mixes versus aliquoted frozen master mixes made with two of the fast qPCR mixes (Life Technologies TaqMan FastAdvanced Master Mix, and Bio-Rad SsoFast Probes Supermix with Rox), chosen based on their performance and compatibility with existing PCR cycling conditions. The data demonstrate that the frozen master mixes retain excellent performance over a period of at least 10 weeks. During the parallel testing using clinical specimens, no difference in quantitative results was observed between the preassembled frozen master mixes and freshly prepared master mixes. Preassembled fast real-time qPCR frozen master mixes perform well and represent an additional strategy laboratories can implement to reduce assay preparation times, and to minimize technical errors and effort necessary to perform clinical PCR. © 2015 Wiley Periodicals, Inc.

  2. Quantitative assessment of the microbial risk of leafy greens from farm to consumption: preliminary framework, data, and risk estimates.

    PubMed

    Danyluk, Michelle D; Schaffner, Donald W

    2011-05-01

    This project was undertaken to relate what is known about the behavior of Escherichia coli O157:H7 under laboratory conditions and integrate this information to what is known regarding the 2006 E. coli O157:H7 spinach outbreak in the context of a quantitative microbial risk assessment. The risk model explicitly assumes that all contamination arises from exposure in the field. Extracted data, models, and user inputs were entered into an Excel spreadsheet, and the modeling software @RISK was used to perform Monte Carlo simulations. The model predicts that cut leafy greens that are temperature abused will support the growth of E. coli O157:H7, and populations of the organism may increase by as much a 1 log CFU/day under optimal temperature conditions. When the risk model used a starting level of -1 log CFU/g, with 0.1% of incoming servings contaminated, the predicted numbers of cells per serving were within the range of best available estimates of pathogen levels during the outbreak. The model predicts that levels in the field of -1 log CFU/g and 0.1% prevalence could have resulted in an outbreak approximately the size of the 2006 E. coli O157:H7 outbreak. This quantitative microbial risk assessment model represents a preliminary framework that identifies available data and provides initial risk estimates for pathogenic E. coli in leafy greens. Data gaps include retail storage times, correlations between storage time and temperature, determining the importance of E. coli O157:H7 in leafy greens lag time models, and validation of the importance of cross-contamination during the washing process.

  3. Real time blood testing using quantitative phase imaging.

    PubMed

    Pham, Hoa V; Bhaduri, Basanta; Tangella, Krishnarao; Best-Popescu, Catherine; Popescu, Gabriel

    2013-01-01

    We demonstrate a real-time blood testing system that can provide remote diagnosis with minimal human intervention in economically challenged areas. Our instrument combines novel advances in label-free optical imaging with parallel computing. Specifically, we use quantitative phase imaging for extracting red blood cell morphology with nanoscale sensitivity and NVIDIA's CUDA programming language to perform real time cellular-level analysis. While the blood smear is translated through focus, our system is able to segment and analyze all the cells in the one megapixel field of view, at a rate of 40 frames/s. The variety of diagnostic parameters measured from each cell (e.g., surface area, sphericity, and minimum cylindrical diameter) are currently not available with current state of the art clinical instruments. In addition, we show that our instrument correctly recovers the red blood cell volume distribution, as evidenced by the excellent agreement with the cell counter results obtained on normal patients and those with microcytic and macrocytic anemia. The final data outputted by our instrument represent arrays of numbers associated with these morphological parameters and not images. Thus, the memory necessary to store these data is of the order of kilobytes, which allows for their remote transmission via, for example, the cellular network. We envision that such a system will dramatically increase access for blood testing and furthermore, may pave the way to digital hematology.

  4. Single-Use Poly(etheretherketone) Solid-Phase Microextraction-Transmission Mode Devices for Rapid Screening and Quantitation of Drugs of Abuse in Oral Fluid and Urine via Direct Analysis in Real-Time Tandem Mass Spectrometry.

    PubMed

    Vasiljevic, Tijana; Gómez-Ríos, Germán Augusto; Pawliszyn, Janusz

    2018-01-02

    The analysis of oral fluid (OF) and urine samples to detect drug consumption has garnered considerable attention as alternative biomatrices. Efficient implementation of microextraction and ambient ionization technologies for rapid detection of target compounds in such biomatrices creates a need for biocompatible devices which can be implemented for in vivo sampling and easily interfaced with mass spectrometry (MS) analyzers. This study introduces a novel solid-phase microextraction-transmission mode (SPME-TM) device made of poly(etheretherketone) (PEEK) mesh that can rapidly detect prohibited substances in biofluids via direct analysis in real-time tandem MS (DART-MS/MS). PEEK mesh was selected due to its biocompatibility, excellent resistance to various organic solvents, and its ability to withstand relatively high temperatures (≤350 °C). The meshes were coated with hydrophilic-lipophilic-balance particle-poly(acrylonitrile) (HLB-PAN) slurry. The robustness of the coated meshes was tested by performing rapid vortex agitation (≥3200 rpm) in LC/MS-grade solvents and by exposing them to the DART source jet stream at typical operational temperatures (∼250-350 °C). PEEK SPME-TM devices proved to be robust and were therefore used to perform ex vivo analysis of drugs of abuse spiked in urine and OF samples. Excellent results were obtained for all analytes under study; furthermore, the tests yielded satisfactory limits of quantitation (median, ∼0.5 ng mL -1 ), linearity (≥0.99), and accuracy (80-120%) over the evaluated range (0.5-200 ng mL -1 ). This research highlights plastic SPME-TM's potential usefulness as a method for rapidly screening for prohibited substances in on-site/in vivo scenarios, such as roadside or workplace drug testing, antidoping controls, and pain management programs.

  5. A modified ion-selective electrode method for measurement of chloride in sweat.

    PubMed

    Finley, P R; Dye, J A; Lichti, D A; Byers, J M; Williams, R J

    1978-06-01

    A modified method of analysis of sweat chloride concentration with an ion-selective electrode is presented. The original method of sweat chloride analysis proposed by the Orion Research Corporation (Cambridge, Massachusetts 02139) is inadequate because it produces erratic and misleading results. The modified method was compared with the reference quantitative method of Gibson and Cooke. In the modified method, individual electrode pads are cut and placed in the electrodes rather than using the pads supplied by the company; pilocarpine nitrate (2,000 mg/l) is used in place of pilocarpine HCl (640 mg/l); sodium bicarbonate as the weak electrolyte is used instead of K2SO4. A 10-minute period for sweat accumulation is employed rather than a zero-time collection as in the original Orion method. The modification has been studied for reproducibility in individuals, reproducibility between right and left arm in individuals; it has been compared extensively with the quantitative method of Gibson and Cooke, both in normal individuals and in patients with cystic fibrosis. There is excellent agreement between the modified method and the quantitative reference method. There appears to be a slight bias toward higher concentrations of chloride from the right arm compared with the left arm, but this difference is not medically significant.

  6. Quantitative analysis of perfumes in talcum powder by using headspace sorptive extraction.

    PubMed

    Ng, Khim Hui; Heng, Audrey; Osborne, Murray

    2012-03-01

    Quantitative analysis of perfume dosage in talcum powder has been a challenge due to interference of the matrix and has so far not been widely reported. In this study, headspace sorptive extraction (HSSE) was validated as a solventless sample preparation method for the extraction and enrichment of perfume raw materials from talcum powder. Sample enrichment is performed on a thick film of poly(dimethylsiloxane) (PDMS) coated onto a magnetic stir bar incorporated in a glass jacket. Sampling is done by placing the PDMS stir bar in the headspace vial by using a holder. The stir bar is then thermally desorbed online with capillary gas chromatography-mass spectrometry. The HSSE method is based on the same principles as headspace solid-phase microextraction (HS-SPME). Nevertheless, a relatively larger amount of extracting phase is coated on the stir bar as compared to SPME. Sample amount and extraction time were optimized in this study. The method has shown good repeatability (with relative standard deviation no higher than 12.5%) and excellent linearity with correlation coefficients above 0.99 for all analytes. The method was also successfully applied in the quantitative analysis of talcum powder spiked with perfume at different dosages. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. CT colonography with rectal iodine tagging: Feasibility and comparison with oral tagging in a colorectal cancer screening population.

    PubMed

    Neri, Emanuele; Mantarro, Annalisa; Faggioni, Lorenzo; Scalise, Paola; Bemi, Pietro; Pancrazi, Francesca; D'Ippolito, Giuseppe; Bartolozzi, Carlo

    2015-09-01

    To evaluate feasibility, diagnostic performance, patient acceptance, and overall examination time of CT colonography (CTC) performed through rectal administration of iodinated contrast material. Six-hundred asymptomatic subjects (male:female=270:330; mean 63 years) undergoing CTC for colorectal cancer screening on an individual basis were consecutively enrolled in the study. Out of them, 503 patients (group 1) underwent CTC with rectal tagging, of which 55 had a total of 77 colonic lesions. The remaining 97 patients (group 2) were randomly selected to receive CTC with oral tagging of which 15 had a total of 20 colonic lesions. CTC findings were compared with optical colonoscopy, and per-segment image quality was visually assessed using a semi-quantitative score (1=poor, 2=adequate, 3=excellent). In 70/600 patients (11.7%), CTC was performed twice with both types of tagging over a 5-year follow-up cancer screening program. In this subgroup, patient acceptance was rated via phone interview two weeks after CTC using a semi-quantitative scale (1=poor, 2=fair, 3=average, 4=good, 5=excellent). Mean per-polyp sensitivity, specificity, positive and negative predictive values of CTC with rectal vs oral tagging were 96.1% (CI95% 85.4÷99.3%) vs 89.4% (CI95% 65.4÷98.1%), 95.3% (CI95% 90.7÷97.8%) vs 95.8% (CI95% 87.6÷98.9%), 86.0% (CI95% 73.6÷93.3) vs 85.0% (CI95% 61.1÷96.0%), and 98.8% (CI95% 95.3÷99.8%) vs 97.2% (CI95% 89.4÷99.5%), respectively (p>0.05). Polyp detection rates were not statistically different between groups 1 and 2 (p>0.05). Overall examination time was significantly shorter with rectal than with oral tagging (18.3±3.5 vs 215.6±10.3 minutes, respectively; p<0.0001). Rectal iodine tagging can be an effective alternative to oral tagging for CTC with the advantages of greater patient acceptance and lower overall examination time. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Student evaluations of teaching: teaching quantitative courses can be hazardous to one’s career

    PubMed Central

    Smibert, Dylan

    2017-01-01

    Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors’ teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards. PMID:28503380

  9. Student evaluations of teaching: teaching quantitative courses can be hazardous to one's career.

    PubMed

    Uttl, Bob; Smibert, Dylan

    2017-01-01

    Anonymous student evaluations of teaching (SETs) are used by colleges and universities to measure teaching effectiveness and to make decisions about faculty hiring, firing, re-appointment, promotion, tenure, and merit pay. Although numerous studies have found that SETs correlate with various teaching effectiveness irrelevant factors (TEIFs) such as subject, class size, and grading standards, it has been argued that such correlations are small and do not undermine the validity of SETs as measures of professors' teaching effectiveness. However, previous research has generally used inappropriate parametric statistics and effect sizes to examine and to evaluate the significance of TEIFs on personnel decisions. Accordingly, we examined the influence of quantitative vs. non-quantitative courses on SET ratings and SET based personnel decisions using 14,872 publicly posted class evaluations where each evaluation represents a summary of SET ratings provided by individual students responding in each class. In total, 325,538 individual student evaluations from a US mid-size university contributed to theses class evaluations. The results demonstrate that class subject (math vs. English) is strongly associated with SET ratings, has a substantial impact on professors being labeled satisfactory vs. unsatisfactory and excellent vs. non-excellent, and the impact varies substantially depending on the criteria used to classify professors as satisfactory vs. unsatisfactory. Professors teaching quantitative courses are far more likely not to receive tenure, promotion, and/or merit pay when their performance is evaluated against common standards.

  10. Fuzzy-Set Case Studies

    ERIC Educational Resources Information Center

    Mikkelsen, Kim Sass

    2017-01-01

    Contemporary case studies rely on verbal arguments and set theory to build or evaluate theoretical claims. While existing procedures excel in the use of qualitative information (information about kind), they ignore quantitative information (information about degree) at central points of the analysis. Effectively, contemporary case studies rely on…

  11. Towards quantitative off-axis electron holographic mapping of the electric field around the tip of a sharp biased metallic needle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beleggia, M.; Helmholtz-Zentrum Berlin für Materialien und Energie, Berlin; Kasama, T.

    We apply off-axis electron holography and Lorentz microscopy in the transmission electron microscope to map the electric field generated by a sharp biased metallic tip. A combination of experimental data and modelling provides quantitative information about the potential and the field around the tip. Close to the tip apex, we measure a maximum field intensity of 82 MV/m, corresponding to a field k factor of 2.5, in excellent agreement with theory. In order to verify the validity of the measurements, we use the inferred charge density distribution in the tip region to generate simulated phase maps and Fresnel (out-of-focus) imagesmore » for comparison with experimental measurements. While the overall agreement is excellent, the simulations also highlight the presence of an unexpected astigmatic contribution to the intensity in a highly defocused Fresnel image, which is thought to result from the geometry of the applied field.« less

  12. Validation of Reference Genes for Gene Expression by Quantitative Real-Time RT-PCR in Stem Segments Spanning Primary to Secondary Growth in Populus tomentosa.

    PubMed

    Wang, Ying; Chen, Yajuan; Ding, Liping; Zhang, Jiewei; Wei, Jianhua; Wang, Hongzhi

    2016-01-01

    The vertical segments of Populus stems are an ideal experimental system for analyzing the gene expression patterns involved in primary and secondary growth during wood formation. Suitable internal control genes are indispensable to quantitative real time PCR (qRT-PCR) assays of gene expression. In this study, the expression stability of eight candidate reference genes was evaluated in a series of vertical stem segments of Populus tomentosa. Analysis through software packages geNorm, NormFinder and BestKeeper showed that genes ribosomal protein (RP) and tubulin beta (TUBB) were the most unstable across the developmental stages of P. tomentosa stems, and the combination of the three reference genes, eukaryotic translation initiation factor 5A (eIF5A), Actin (ACT6) and elongation factor 1-beta (EF1-beta) can provide accurate and reliable normalization of qRT-PCR analysis for target gene expression in stem segments undergoing primary and secondary growth in P. tomentosa. These results provide crucial information for transcriptional analysis in the P. tomentosa stem, which may help to improve the quality of gene expression data in these vertical stem segments, which constitute an excellent plant system for the study of wood formation.

  13. Multiplexed MRM-based quantitation of candidate cancer biomarker proteins in undepleted and non-enriched human plasma.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Borchers, Christoph H

    2013-07-01

    An emerging approach for multiplexed targeted proteomics involves bottom-up LC-MRM-MS, with stable isotope-labeled internal standard peptides, to accurately quantitate panels of putative disease biomarkers in biofluids. In this paper, we used this approach to quantitate 27 candidate cancer-biomarker proteins in human plasma that had not been treated by immunoaffinity depletion or enrichment techniques. These proteins have been reported as biomarkers for a variety of human cancers, from laryngeal to ovarian, with breast cancer having the highest correlation. We implemented measures to minimize the analytical variability, improve the quantitative accuracy, and increase the feasibility and applicability of this MRM-based method. We have demonstrated excellent retention time reproducibility (median interday CV: 0.08%) and signal stability (median interday CV: 4.5% for the analytical platform and 6.1% for the bottom-up workflow) for the 27 biomarker proteins (represented by 57 interference-free peptides). The linear dynamic range for the MRM assays spanned four orders-of-magnitude, with 25 assays covering a 10(3) -10(4) range in protein concentration. The lowest abundance quantifiable protein in our biomarker panel was insulin-like growth factor 1 (calculated concentration: 127 ng/mL). Overall, the analytical performance of this assay demonstrates high robustness and sensitivity, and provides the necessary throughput and multiplexing capabilities required to verify and validate cancer-associated protein biomarker panels in human plasma, prior to clinical use. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Quantitative determination of Escherichia coli based on the electrochemical measurement of bacterial catalase activity using H2O2-selective organic/inorganic-hybrid sol-gel film-modified Pt electrode.

    PubMed

    Hasebe, Yasushi; Fukuzawa, Michiru; Matsuhisa, Hironori

    2009-01-01

    Quantitative determination of Escherichia coli (E. coli) concentration was achieved by measuring the intrinsic catalase activity of E. coli using novel H2O2-selective organic/inorganic-hybrid sol-gel film-modified platinum (Pt) wire electrode. This hybrid sol-gel film is composed of three kinds of organosilanes and two biopolymers (i.e., chitosan and bovine serum albumin), and exhibited an excellent permselectivity toward H2O2 based on a size-exclusive mechanism. The steady-state anodic current for 100 [xmol/L H2O2 at +0.6 V (vs. Ag/AgCl) in 0.1 mol/L phosphate buffer (pH 6.5) solution was apparently diminished by the addition of E. coli samples, due to the decomposition of H2O2 by intrinsic catalase activity of E. coli. The time-dependent decrease in current (-AI/At) was significantly dependent on the E. coli concentration. The -AI/At was enhanced by the permeabilization pretreatment of E. coli samples with the mixed solution of polymyxin B and lysozyme. This H2O2-selective organic/inorganic-hybrid sol-gel film-modified platinum (Pt) wire electrode allowed quantitative determination of E. coli concentration ranging from 10(6) to 10(9) CFU/mL within 30 min. This method required no label and complicated procedure, and allowed rapid, simple and cost-effective quantitative electrochemical determination of catalase-positive bacteria.

  15. Assessing Psychodynamic Conflict.

    PubMed

    Simmonds, Joshua; Constantinides, Prometheas; Perry, J Christopher; Drapeau, Martin; Sheptycki, Amanda R

    2015-09-01

    Psychodynamic psychotherapies suggest that symptomatic relief is provided, in part, with the resolution of psychic conflicts. Clinical researchers have used innovative methods to investigate such phenomenon. This article aims to review the literature on quantitative psychodynamic conflict rating scales. An electronic search of the literature was conducted to retrieve quantitative observer-rated scales used to assess conflict noting each measure's theoretical model, information source, and training and clinical experience required. Scales were also examined for levels of reliability and validity. Five quantitative observer-rated conflict scales were identified. Reliability varied from poor to excellent with each measure demonstrating good validity. However a small number of studies and limited links to current conflict theory suggest further clinical research is needed.

  16. Bose-Einstein condensation in atomic alkali gases

    NASA Astrophysics Data System (ADS)

    Dodd, Robert J.

    1998-05-01

    I present a review of the time-independent Gross-Pitaevskii (GP), Bogoliubov, and finite-temperature Hartree-Fock-Bogoliubov (HFB) mean-field theories used to study trapped, Bose-Einstein condensed alkali gases. Numerical solutions of the (zero-temperature) GP equation are presented for attractive (negative scattering length) and repulsive (positive scattering length) interactions. Comparison is made with the Thomas-Fermi and (variational) trial wavefunction appr oximations that are used in the literature to study condensed gases. Numerical calculations of the (zero-temperature) Bogoliubov quasi-particle excitation frequencies are found to be in excellent agreement with the experimental results. The finite-temperature properties of condensed gases are examined using the Popov approximation (of the HFB theory) and a simple two-gas model. Specific, quantitative comparisons are made with experimental results for finite-temperature excitation frequencies. Qualitative comparisons are made between the results of the Popov approximation, two-gas model, and other published models for condensate fraction and thermal density distribution. The time-independent mean-field theories are found to be in excellent agreement with experimental results at relatively low temperatures (high condensate fractions). However, at higher temperatures (and condensate fractions of less than 50%) there are significant discrepancies between experimental data and theoretical calculations. This work was undertaken at the University of Maryland at College Park and was supported in part by the National Science Foundation (PHY-9601261) and the U.S. Office of Naval Research.

  17. Evaluation of macrocyclic hydroxyisophthalamide ligands as chelators for zirconium-89

    DOE PAGES

    Bhatt, Nikunj B.; Pandya, Darpan N.; Xu, Jide; ...

    2017-06-02

    The development of bifunctional chelators (BFCs) for zirconium-89 immuno-PET applications is an area of active research. We report the synthesis and evaluation of octadentate hydroxyisophthalamide ligands (1 and 2) as zirconium-89 chelators. And while both radiometal complexes could be prepared quantitatively and with excellent specific activity, preparation of 89Zr-1 required elevated temperature and an increased reaction time. 89Zr-1 was more stable than 89Zr-2 when challenged in vitro by excess DTPA or serum proteins and in vivo during acute biodistribution studies. The differences in radiometal complex stability arise from structural changes between the two ligand systems, and suggest further ligand optimizationmore » is necessary to enhance 89Zr chelation.« less

  18. Evaluation of macrocyclic hydroxyisophthalamide ligands as chelators for zirconium-89

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatt, Nikunj B.; Pandya, Darpan N.; Xu, Jide

    The development of bifunctional chelators (BFCs) for zirconium-89 immuno-PET applications is an area of active research. We report the synthesis and evaluation of octadentate hydroxyisophthalamide ligands (1 and 2) as zirconium-89 chelators. And while both radiometal complexes could be prepared quantitatively and with excellent specific activity, preparation of 89Zr-1 required elevated temperature and an increased reaction time. 89Zr-1 was more stable than 89Zr-2 when challenged in vitro by excess DTPA or serum proteins and in vivo during acute biodistribution studies. The differences in radiometal complex stability arise from structural changes between the two ligand systems, and suggest further ligand optimizationmore » is necessary to enhance 89Zr chelation.« less

  19. Fully automated registration of first-pass myocardial perfusion MRI using independent component analysis.

    PubMed

    Milles, J; van der Geest, R J; Jerosch-Herold, M; Reiber, J H C; Lelieveldt, B P F

    2007-01-01

    This paper presents a novel method for registration of cardiac perfusion MRI. The presented method successfully corrects for breathing motion without any manual interaction using Independent Component Analysis to extract physiologically relevant features together with their time-intensity behavior. A time-varying reference image mimicking intensity changes in the data of interest is computed based on the results of ICA, and used to compute the displacement caused by breathing for each frame. Qualitative and quantitative validation of the method is carried out using 46 clinical quality, short-axis, perfusion MR datasets comprising 100 images each. Validation experiments showed a reduction of the average LV motion from 1.26+/-0.87 to 0.64+/-0.46 pixels. Time-intensity curves are also improved after registration with an average error reduced from 2.65+/-7.89% to 0.87+/-3.88% between registered data and manual gold standard. We conclude that this fully automatic ICA-based method shows an excellent accuracy, robustness and computation speed, adequate for use in a clinical environment.

  20. Earthquake Magnitude: A Teaching Module for the Spreadsheets Across the Curriculum Initiative

    NASA Astrophysics Data System (ADS)

    Wetzel, L. R.; Vacher, H. L.

    2006-12-01

    Spreadsheets Across the Curriculum (SSAC) is a library of computer-based activities designed to reinforce or teach quantitative-literacy or mathematics concepts and skills in context. Each activity (called a "module" in the SSAC project) consists of a PowerPoint presentation with embedded Excel spreadsheets. Each module focuses on one or more problems for students to solve. Each student works through a presentation, thinks about the in-context problem, figures out how to solve it mathematically, and builds the spreadsheets to calculate and examine answers. The emphasis is on mathematical problem solving. The intention is for the in- context problems to span the entire range of subjects where quantitative thinking, number sense, and math non-anxiety are relevant. The self-contained modules aim to teach quantitative concepts and skills in a wide variety of disciplines (e.g., health care, finance, biology, and geology). For example, in the Earthquake Magnitude module students create spreadsheets and graphs to explore earthquake magnitude scales, wave amplitude, and energy release. In particular, students realize that earthquake magnitude scales are logarithmic. Because each step in magnitude represents a 10-fold increase in wave amplitude and approximately a 30-fold increase in energy release, large earthquakes are much more powerful than small earthquakes. The module has been used as laboratory and take-home exercises in small structural geology and solid earth geophysics courses with upper level undergraduates. Anonymous pre- and post-tests assessed students' familiarity with Excel as well as other quantitative skills. The SSAC library consists of 27 modules created by a community of educators who met for one-week "module-making workshops" in Olympia, Washington, in July of 2005 and 2006. The educators designed the modules at the workshops both to use in their own classrooms and to make available for others to adopt and adapt at other locations and in other classes. When fully developed, the module collection will be available at the on-line Science Education Resource Center at Carleton College, searchable by quantitative skill, subject area, and Excel level. The number of modules will continue to grow through individual efforts as well as an additional module-making workshop in July of 2007 facilitated by the Washington Center for Improving the Quality of Undergraduate Education.

  1. Evaluating a linearized Euler equations model for strong turbulence effects on sound propagation.

    PubMed

    Ehrhardt, Loïc; Cheinet, Sylvain; Juvé, Daniel; Blanc-Benon, Philippe

    2013-04-01

    Sound propagation outdoors is strongly affected by atmospheric turbulence. Under strongly perturbed conditions or long propagation paths, the sound fluctuations reach their asymptotic behavior, e.g., the intensity variance progressively saturates. The present study evaluates the ability of a numerical propagation model based on the finite-difference time-domain solving of the linearized Euler equations in quantitatively reproducing the wave statistics under strong and saturated intensity fluctuations. It is the continuation of a previous study where weak intensity fluctuations were considered. The numerical propagation model is presented and tested with two-dimensional harmonic sound propagation over long paths and strong atmospheric perturbations. The results are compared to quantitative theoretical or numerical predictions available on the wave statistics, including the log-amplitude variance and the probability density functions of the complex acoustic pressure. The match is excellent for the evaluated source frequencies and all sound fluctuations strengths. Hence, this model captures these many aspects of strong atmospheric turbulence effects on sound propagation. Finally, the model results for the intensity probability density function are compared with a standard fit by a generalized gamma function.

  2. Engineering cell-compatible paper chips for cell culturing, drug screening, and mass spectrometric sensing.

    PubMed

    Chen, Qiushui; He, Ziyi; Liu, Wu; Lin, Xuexia; Wu, Jing; Li, Haifang; Lin, Jin-Ming

    2015-10-28

    Paper-supported cell culture is an unprecedented development for advanced bioassays. This study reports a strategy for in vitro engineering of cell-compatible paper chips that allow for adherent cell culture, quantitative assessment of drug efficiency, and label-free sensing of intracellular molecules via paper spray mass spectrometry. The polycarbonate paper is employed as an excellent alternative bioscaffold for cell distribution, adhesion, and growth, as well as allowing for fluorescence imaging without light scattering. The cell-cultured paper chips are thus amenable to fabricate 3D tissue construction and cocultures by flexible deformation, stacks and assembly by layers of cells. As a result, the successful development of cell-compatible paper chips subsequently offers a uniquely flexible approach for in situ sensing of live cell components by paper spray mass spectrometry, allowing profiling the cellular lipids and quantitative measurement of drug metabolism with minimum sample pretreatment. Consequently, the developed paper chips for adherent cell culture are inexpensive for one-time use, compatible with high throughputs, and amenable to label-free and rapid analysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Transition-state theory predicts clogging at the microscale

    NASA Astrophysics Data System (ADS)

    Laar, T. Van De; Klooster, S. Ten; Schroën, K.; Sprakel, J.

    2016-06-01

    Clogging is one of the main failure mechanisms encountered in industrial processes such as membrane filtration. Our understanding of the factors that govern the build-up of fouling layers and the emergence of clogs is largely incomplete, so that prevention of clogging remains an immense and costly challenge. In this paper we use a microfluidic model combined with quantitative real-time imaging to explore the influence of pore geometry and particle interactions on suspension clogging in constrictions, two crucial factors which remain relatively unexplored. We find a distinct dependence of the clogging rate on the entrance angle to a membrane pore which we explain quantitatively by deriving a model, based on transition-state theory, which describes the effect of viscous forces on the rate with which particles accumulate at the channel walls. With the same model we can also predict the effect of the particle interaction potential on the clogging rate. In both cases we find excellent agreement between our experimental data and theory. A better understanding of these clogging mechanisms and the influence of design parameters could form a stepping stone to delay or prevent clogging by rational membrane design.

  4. Making the Right Moves: Promoting Smart Growth and Active Aging in Communities

    EPA Science Inventory

    This article describes an award program sponsored by the U.S. Environmental Protection Agency for excellence in smart growth and active aging. Having examined qualitative and quantitative data, we suggest that any community can foster changes to improve the health and well-being ...

  5. Evaluating the Fine Arts Program at the Center for Excellence in Disabilities

    ERIC Educational Resources Information Center

    Schlosnagle, Leo; McBean, Amanda L.; Cutlip, Milisa; Panzironi, Helen; Jarmolowicz, David P.

    2014-01-01

    Art programs for people with disabilities may encourage creativity, promote engagement, emphasize inclusion, and extend access and opportunities for community involvement. This mixed methods study utilized quantitative and qualitative data, repeated measures, action research, and stakeholder collaboration to develop and implement an evaluation…

  6. Quantitative force measurements in liquid using frequency modulation atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Uchihashi, Takayuki; Higgins, Michael J.; Yasuda, Satoshi; Jarvis, Suzanne P.; Akita, Seiji; Nakayama, Yoshikazu; Sader, John E.

    2004-10-01

    The measurement of short-range forces with the atomic force microscope (AFM) typically requires implementation of dynamic techniques to maintain sensitivity and stability. While frequency modulation atomic force microscopy (FM-AFM) is used widely for high-resolution imaging and quantitative force measurements in vacuum, quantitative force measurements using FM-AFM in liquids have proven elusive. Here we demonstrate that the formalism derived for operation in vacuum can also be used in liquids, provided certain modifications are implemented. To facilitate comparison with previous measurements taken using surface forces apparatus, we choose a model system (octamethylcyclotetrasiloxane) that is known to exhibit short-ranged structural ordering when confined between two surfaces. Force measurements obtained are found to be in excellent agreement with previously reported results. This study therefore establishes FM-AFM as a powerful tool for the quantitative measurement of forces in liquid.

  7. Graphene-Oxide-Decorated Microporous Polyetheretherketone with Superior Antibacterial Capability and In Vitro Osteogenesis for Orthopedic Implant.

    PubMed

    Ouyang, Ling; Deng, Yi; Yang, Lei; Shi, Xiuyuan; Dong, Taosheng; Tai, Youyi; Yang, Weizhong; Chen, Zhi-Gang

    2018-05-02

    Due to its similar elastic modulus of human bones, polyetheretherketone (PEEK) has been considered as an excellent cytocompatible material. However, the bioinertness, poor osteoconduction, and weak antibacterial activity of PEEK limit its wide applications in clinics. In this study, a facile strategy is developed to prepare graphene oxide (GO) modified sulfonated polyetheretherketone (SPEEK) (GO-SPEEK) through a simple dip-coating method. After detailed characterization, it is found that the GO closely deposits on the surface of PEEK, which is attributed to the π-π stacking interaction between PEEK and GO. Antibacterial tests reveal that the GO-SPEEK exhibits excellent suppression toward Escherichia coli. In vitro cell attachment, growth, differentiation, alkaline phosphatase activity, quantitative real-time polymerase chain reaction analyses, and calcium mineral deposition all illustrate that the GO-SPEEK substrate can significantly accelerate the proliferation and osteogenic differentiation of osteoblast-like MG-63 cells compared with those on PEEK and SPEEK groups. These results suggest that the GO-SPEEK has an improved antibacterial activity and cytocompatibility in vitro, showing that the developed GO-SPEEK has a great potential as the bioactive implant material in bone tissue engineering. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A novel fluorimetric sensing platform for highly sensitive detection of organophosphorus pesticides by using egg white-encapsulated gold nanoclusters.

    PubMed

    Yan, Xu; Li, Hongxia; Hu, Tianyu; Su, Xingguang

    2017-05-15

    Assays for organophosphorus pesticides (OPs) with high sensitivity as well as on-site screening have been urgently required to protect ecosystem and prevent disease. Herein, a novel fluorimetric sensing platform was constructed for quantitative detection of OPs via tyrosinase (TYR) enzyme-controlled quenching of gold nanoclusters (AuNCs). One-step green synthetic approach was developed for the synthesis of AuNCs by using chicken egg white (CEW) as template and stabilizer. Initially, TYR can catalyze the oxidation of dopamine to dopaminechrome, which can efficiently quench the fluorescence intensity of AuNCs at 630nm based on dynamic quenching process. However, with the presence of OPs, the activity of TYR was inhibited, resulting in the fluorescence recovery of AuNCs. This proposed fluorescence platform was demonstrated to enable rapid detection for OPs (paraoxon as model) and to provide excellent sensitivity with a detection limit of 0.1ngmL -1 . Significantly, the fluorescence probe was used to prepare paper-based test strips for visual detection of OPs, which validated the excellent potential for real-time and on-site application. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Simultaneous quantitation of cytokeratin-19 fragment and carcinoembryonic antigen in human serum via quantum dot-doped nanoparticles.

    PubMed

    Chen, Zhenhua; Liang, Rongliang; Guo, Xinxin; Liang, Junyu; Deng, Qiaoting; Li, Min; An, Taixue; Liu, Tiancai; Wu, Yingsong

    2017-05-15

    A novel quantum dot-doped polystyrene nanoparticles-based lateral flow test strips (QPs-LFTS) system was developed to simultaneously detect a cytokeratin-19 fragment (CYFRA 21-1) and carcinoembryonic antigen (CEA) in human serum to aid the diagnosis and prognosis of lung cancer. Quantum dot-doped carboxylate-functionalized polystyrene nanoparticles (QPs) were prepared and introduced as fluorescent reporters in QPs-LFTS. The detection was based on a sandwich immunoassay and performed on lateral flow test strips, with an assay time of 15min. The strips were read by a fluorescence strip reader to obtain the fluorescence peak heights of the test lines (H T ) and the control line (H C ). The ratio of H T /H C was used for quantitation. The QPs showed excellent photoproperties and good performance. Under optimal conditions, the QPs-LFTS system exhibited a wide linear range for CYFRA 21-1 (1.3-480ng/mL) and CEA (2.8-680ng/mL). The detection limits for CYFRA 21-1 and CEA were 0.16 and 0.35ng/mL, respectively. The recovery and reproducibility of the method were satisfactory. Furthermore, excellent correlations (n =120, R 2 =0.9862, P<0.0001 for CYFRA 21-1; n =70, R 2 =0.9509, P<0.0001 for CEA) were obtained between the QPs-LFTS and commercially available chemiluminescence immunoassay kits in clinical serum testing. The results indicate that this developed test system is highly efficient and is expected to be useful for early screening and prognosis evaluation for lung cancer patients. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Expert Reflections on Effective Online Instruction: Importance of Course Content

    ERIC Educational Resources Information Center

    Ryan, Michael; Jonick, Christine; Langub, Lee Woodham

    2015-01-01

    This study seeks to identify common factors that leaders in online instruction consider most critical to successful teaching and learning at a distance. A quantitative and qualitative analysis of the teaching philosophy narratives of the nominees for the "University System of Georgia Regents' Teaching Excellence Award for Online…

  11. High-throughput genotoxicity assay identifies antioxidants as inducers of DNA damage response and cell death

    EPA Science Inventory

    Human ATAD5 is an excellent biomarker for identifying genotoxic compounds because ATADS protein levels increase post-transcriptionally following exposure to a variety of DNA damaging agents. Here we report a novel quantitative high-throughput ATAD5-Iuciferase assay that can moni...

  12. An exercise to teach quantitative analysis and modeling using Excel-based analysis of the carbon cycle in the anthropocene

    NASA Astrophysics Data System (ADS)

    Stoll, Heather

    2013-04-01

    A computer modeling exercise was created to allows students to investigate the consequences of fossil fuel burning and land use change on the amount of carbon dioxide in the atmosphere. Students work with a simple numerical model of the carbon cycle which is rendered in Excel, and conduct a set of different sensitivity tests with different amounts and rate of C additions, and then graph and discuss their results. In the recommended approach, the model is provided to students without the biosphere and in class the formulas to integrate this module are typed into Excel simultaneously by instructor and students, helping students understand how the larger model is set up. In terms of content, students learn to recognize the redistribution of fossil fuel carbon between the ocean and atmosphere, and distinguish the consequences of rapid vs slow rates of addition of fossil fuel CO2 and the reasons for this difference. Students become familiar with the use of formulas in Excel and working with a large (300 rows, 20 columns) worksheet and gain competence in graphical representation of multiple scenarios. Students learn to appreciate the power and limitations of numerical models of complex cycles, the concept of inverse and forward models, and sensitivity tests. Finally, students learn that a reasonable hypothesis, may be "reasonable" but still not quantitatively sufficient - in this case, that the "Industrial Revolution" was not the source of increasing atmospheric CO2 from 1750-1900. The described activity is available to educators on the Teach the Earth portal of the Science Education Research Center (SERC) http://serc.carleton.edu/quantskills/activities/68751.html.

  13. Comparison of longitudinal excursion of a nerve-phantom model using quantitative ultrasound imaging and motion analysis system methods: A convergent validity study.

    PubMed

    Paquette, Philippe; El Khamlichi, Youssef; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2017-08-01

    Quantitative ultrasound imaging is gaining popularity in research and clinical settings to measure the neuromechanical properties of the peripheral nerves such as their capability to glide in response to body segment movement. Increasing evidence suggests that impaired median nerve longitudinal excursion is associated with carpal tunnel syndrome. To date, psychometric properties of longitudinal nerve excursion measurements using quantitative ultrasound imaging have not been extensively investigated. This study investigates the convergent validity of the longitudinal nerve excursion by comparing measures obtained using quantitative ultrasound imaging with those determined with a motion analysis system. A 38-cm long rigid nerve-phantom model was used to assess the longitudinal excursion in a laboratory environment. The nerve-phantom model, immersed in a 20-cm deep container filled with a gelatin-based solution, was moved 20 times using a linear forward and backward motion. Three light-emitting diodes were used to record nerve-phantom excursion with a motion analysis system, while a 5-cm linear transducer allowed simultaneous recording via ultrasound imaging. Both measurement techniques yielded excellent association ( r  = 0.99) and agreement (mean absolute difference between methods = 0.85 mm; mean relative difference between methods = 7.48 %). Small discrepancies were largely found when larger excursions (i.e. > 10 mm) were performed, revealing slight underestimation of the excursion by the ultrasound imaging analysis software. Quantitative ultrasound imaging is an accurate method to assess the longitudinal excursion of an in vitro nerve-phantom model and appears relevant for future research protocols investigating the neuromechanical properties of the peripheral nerves.

  14. Quantitative analysis of virgin coconut oil in cream cosmetics preparations using fourier transform infrared (FTIR) spectroscopy.

    PubMed

    Rohman, A; Man, Yb Che; Sismindari

    2009-10-01

    Today, virgin coconut oil (VCO) is becoming valuable oil and is receiving an attractive topic for researchers because of its several biological activities. In cosmetics industry, VCO is excellent material which functions as a skin moisturizer and softener. Therefore, it is important to develop a quantitative analytical method offering a fast and reliable technique. Fourier transform infrared (FTIR) spectroscopy with sample handling technique of attenuated total reflectance (ATR) can be successfully used to analyze VCO quantitatively in cream cosmetic preparations. A multivariate analysis using calibration of partial least square (PLS) model revealed the good relationship between actual value and FTIR-predicted value of VCO with coefficient of determination (R2) of 0.998.

  15. Ease of intubation: A randomized, double-blind study to compare two doses of rocuronium bromide for endotracheal intubation.

    PubMed

    Shukla, Aparna; Misra, Shilpi

    2016-01-01

    Clinical need for a nondepolarizing agent with a rapid onset time and a brief duration of action has led to the development of rocuronium bromide. The aim of this study was to evaluate optimal dose of rocuronium bromide for intubation and to compare the onset time, duration of action, intubating conditions, and hemodynamic effects of two doses of rocuronium bromide. A prospective, randomized, double-blind study. All the patients were divided in a randomized, double-blind fashion into two groups of twenty patients each. Group I patients received rocuronium bromide 0.6 mg/kg intravenously and intubated at 60 s, Group II patients received rocuronium bromide 0.9 mg/kg and intubated at 60 s. The neuromuscular block was assessed using single twitch stimulation of 0.1 Hz at adductor pollicis muscle of hand at every 10 s. The results were compiled and analyzed statistically using Chi-square test for qualitative data and Student's t -test for quantitative data. Time of onset was significantly shorter ( P < 0.01) and duration of action was prolonged ( P < 0.001) for Group II as compared to Group I. The intubating conditions were (excellent + good) in 100% patients of Group II and (excellent + good) in 80% of Group I. There was no significant change in pulse rate and mean arterial pressure from the baseline value after the administration of muscle relaxants in either of the two groups. Rocuronium bromide 0.9 mg/kg is a safer alternative to rocuronium bromide 0.6 mg/kg for endotracheal intubation with shorter time of onset and better intubating conditions.

  16. Rapid Real-Time PCR Assay for Detection and Quantitation of Mycobacterium avium subsp. paratuberculosis DNA in Artificially Contaminated Milk

    PubMed Central

    O'Mahony, Jim; Hill, Colin

    2004-01-01

    Using fluorescence resonance energy transfer technology and Lightcycler analysis, we developed a real-time PCR assay with primers and probes designed by using IS900 which allowed rapid detection of Mycobacterium avium subsp. paratuberculosis DNA in artificially contaminated milk. Initially, the PCR parameters (including primer and probe levels, assay volume, Mg2+ concentration, and annealing temperature) were optimized. Subsequently, the quantitative ability of the assay was tested and was found to be accurate over a broad linear range (3 × 106 to 3 × 101 copies). The assay sensitivity when purified DNA was used was determined to be as low as five copies, with excellent reproducibility. A range of DNA isolation strategies was developed for isolating M. avium subsp. paratuberculosis DNA from spiked milk, the most effective of which involved the use of 50 mM Tris HCl, 10 mM EDTA, 2% Triton X-100, 4 M guanidinium isothiocyante, and 0.3 M sodium acetate combined with boiling, physical grinding, and nucleic acid spin columns. When this technique was used in conjunction with the real-time PCR assay, it was possible to consistently detect <100 organisms per ml of milk (equivalent to 2,000 organisms per 25 ml). Furthermore, the entire procedure (extraction and PCR) was performed in less than 3 h and was successfully adapted to quantify M. avium subsp. paratuberculosis in spiked milk from heavily and mildly contaminated samples. PMID:15294786

  17. Freezing and frostbite on mount everest: new insights into wind chill and freezing times at extreme altitude.

    PubMed

    Moore, G W K; Semple, J L

    2011-01-01

    Cold injury is an acknowledged risk factor for those who venture into high altitude regions. There is, however, little quantitative information on this risk that can be used to implement mitigation strategies. Here we provide the first characterization of the risk of cold injury near the summit of Mount Everest. This is accomplished through the application of a meteorological dataset that has been demonstrated to characterize conditions in the region as inputs to new parameterizations of wind chill equivalent temperature (WCT) and facial frostbite time (FFT). Throughout the year, the typical WCT near the summit of Everest is always <-30°C, and the typical FFT is always less than 20 min. During the spring climbing season, WCTs of -50°C and FFTs of 5 min are typical; during severe storms, they approach -60°C and 1 min, respectively; values typically found during the winter. Further, we show that the summit barometric pressure is an excellent predictor of summit WCT and FFT. Our results provide the first quantitative characterization of the risk of cold injury on Mount Everest and also allow for the possibility of using barometric pressure, an easily observed parameter, in real time to characterize this risk and to implement mitigation strategies. The results also provide additional confirmation as to the extreme environment experienced by those attempting to summit Mount Everest and other high mountains.

  18. The long-term reliability of static and dynamic quantitative sensory testing in healthy individuals.

    PubMed

    Marcuzzi, Anna; Wrigley, Paul J; Dean, Catherine M; Adams, Roger; Hush, Julia M

    2017-07-01

    Quantitative sensory tests (QSTs) have been increasingly used to investigate alterations in somatosensory function in a wide range of painful conditions. The interpretation of these findings is based on the assumption that the measures are stable and reproducible. To date, reliability of QST has been investigated for short test-retest intervals. The aim of this study was to investigate the long-term reliability of a multimodal QST assessment in healthy people, with testing conducted on 3 occasions over 4 months. Forty-two healthy people were enrolled in the study. Static and dynamic tests were performed, including cold and heat pain threshold (CPT, HPT), mechanical wind-up [wind-up ratio (WUR)], pressure pain threshold (PPT), 2-point discrimination (TPD), and conditioned pain modulation (CPM). Systematic bias, relative reliability and agreement were analysed using repeated measure analysis of variance, intraclass correlation coefficients (ICCs3,1) and SE of the measurement (SEM), respectively. Static QST (CPT, HPT, PPT, and TPD) showed good-to-excellent reliability (ICCs: 0.68-0.90). Dynamic QST (WUR and CPM) showed poor-to-good reliability (ICCs: 0.35-0.61). A significant linear decrease over time was observed for mechanical QST at the back (PPT and TPD) and for CPM (P < 0.01). Static QST were stable over a period of 4 months; however, a small systematic decrease over time has been observed for mechanical QST. Dynamic QST showed considerable variability over time; in particular, CPM using PPT as the test stimulus did not show adequate reliability, suggesting that this test paradigm may be less useful for monitoring individuals over time.

  19. Optical Ptychographic Microscope for Quantitative Bio-Mechanical Imaging

    NASA Astrophysics Data System (ADS)

    Anthony, Nicholas; Cadenazzi, Guido; Nugent, Keith; Abbey, Brian

    The role that mechanical forces play in biological processes such as cell movement and death is becoming of significant interest to further develop our understanding of the inner workings of cells. The most common method used to obtain stress information is photoelasticity which maps a samples birefringence, or its direction dependent refractive indices, using polarized light. However this method only provides qualitative data and for stress information to be useful quantitative data is required. Ptychography is a method for quantitatively determining the phase of a samples complex transmission function. The technique relies upon the collection of multiple overlapping coherent diffraction patterns from laterally displaced points on the sample. The overlap of measurement points provides complementary information that significantly aids in the reconstruction of the complex wavefield exiting the sample and allows for quantitative imaging of weakly interacting specimens. Here we describe recent advances at La Trobe University Melbourne on achieving quantitative birefringence mapping using polarized light ptychography with applications in cell mechanics. Australian Synchrotron, ARC Centre of Excellence for Advanced Molecular Imaging.

  20. Divisional role of quantitative HER2 testing in breast cancer.

    PubMed

    Yamamoto-Ibusuki, Mutsuko; Yamamoto, Yutaka; Fu, Peifen; Yamamoto, Satoko; Fujiwara, Saori; Honda, Yumi; Iyama, Ken-ichi; Iwase, Hirotaka

    2015-03-01

    Human epidermal growth factor receptor 2 (HER2) is amplified in human breast cancers in which therapy targeted to HER2 significantly improves patient outcome. We re-visited the use of real-time quantitative polymerase chain reaction (qPCR)-based assays using formalin-fixed paraffin-embedded (FFPE) tissues as alternative methods and investigated their particular clinical relevance. DNA and RNA were isolated from FFPE specimens and HER2 status was assessed by qPCR in 249 consecutive patients with primary breast cancer. Concordance with results forg immunohistochemistry (IHC) and in situ hybridization (ISH), clinical characteristics and survival was assessed. HER2 gene copy number had a stronger correlation with clinicopathological characteristics and excellent concordance with IHC/ISH results (Sensitivity: 96.7 %; concordance: 99.2 %). HER2 gene expression showed inadequate sensitivity, rendering it unsuitable to determine HER2 status (Sensitivity: 46.7 %; concordance: 92.1 %), but lower HER2 gene expression, leading to the classification of many cases as "false negative", contributed to a prediction of better prognosis within the HER2-amplified subpopulation. Quantitative HER2 assessments are suggested to have evolved their accuracy in this decade, which can be a potential alternative for HER2 diagnosis in line with the in situ method, while HER2 gene expression levels could provide additional information regarding prognosis or therapeutic strategy within a HER2-amplified subpopulation.

  1. Reference genes for reverse transcription quantitative PCR in canine brain tissue.

    PubMed

    Stassen, Quirine E M; Riemers, Frank M; Reijmerink, Hannah; Leegwater, Peter A J; Penning, Louis C

    2015-12-09

    In the last decade canine models have been used extensively to study genetic causes of neurological disorders such as epilepsy and Alzheimer's disease and unravel their pathophysiological pathways. Reverse transcription quantitative polymerase chain reaction is a sensitive and inexpensive method to study expression levels of genes involved in disease processes. Accurate normalisation with stably expressed so-called reference genes is crucial for reliable expression analysis. Following the minimum information for publication of quantitative real-time PCR experiments precise guidelines, the expression of ten frequently used reference genes, namely YWHAZ, HMBS, B2M, SDHA, GAPDH, HPRT, RPL13A, RPS5, RPS19 and GUSB was evaluated in seven brain regions (frontal lobe, parietal lobe, occipital lobe, temporal lobe, thalamus, hippocampus and cerebellum) and whole brain of healthy dogs. The stability of expression varied between different brain areas. Using the GeNorm and Normfinder software HMBS, GAPDH and HPRT were the most reliable reference genes for whole brain. Furthermore based on GeNorm calculations it was concluded that as little as two to three reference genes are sufficient to obtain reliable normalisation, irrespective the brain area. Our results amend/extend the limited previously published data on canine brain reference genes. Despite the excellent expression stability of HMBS, GAPDH and HRPT, the evaluation of expression stability of reference genes must be a standard and integral part of experimental design and subsequent data analysis.

  2. Multisite concordance of apparent diffusion coefficient measurements across the NCI Quantitative Imaging Network.

    PubMed

    Newitt, David C; Malyarenko, Dariya; Chenevert, Thomas L; Quarles, C Chad; Bell, Laura; Fedorov, Andriy; Fennessy, Fiona; Jacobs, Michael A; Solaiyappan, Meiyappan; Hectors, Stefanie; Taouli, Bachir; Muzi, Mark; Kinahan, Paul E; Schmainda, Kathleen M; Prah, Melissa A; Taber, Erin N; Kroenke, Christopher; Huang, Wei; Arlinghaus, Lori R; Yankeelov, Thomas E; Cao, Yue; Aryal, Madhava; Yen, Yi-Fen; Kalpathy-Cramer, Jayashree; Shukla-Dave, Amita; Fung, Maggie; Liang, Jiachao; Boss, Michael; Hylton, Nola

    2018-01-01

    Diffusion weighted MRI has become ubiquitous in many areas of medicine, including cancer diagnosis and treatment response monitoring. Reproducibility of diffusion metrics is essential for their acceptance as quantitative biomarkers in these areas. We examined the variability in the apparent diffusion coefficient (ADC) obtained from both postprocessing software implementations utilized by the NCI Quantitative Imaging Network and online scan time-generated ADC maps. Phantom and in vivo breast studies were evaluated for two ([Formula: see text]) and four ([Formula: see text]) [Formula: see text]-value diffusion metrics. Concordance of the majority of implementations was excellent for both phantom ADC measures and in vivo [Formula: see text], with relative biases [Formula: see text] ([Formula: see text]) and [Formula: see text] (phantom [Formula: see text]) but with higher deviations in ADC at the lowest phantom ADC values. In vivo [Formula: see text] concordance was good, with typical biases of [Formula: see text] to 3% but higher for online maps. Multiple b -value ADC implementations were separated into two groups determined by the fitting algorithm. Intergroup mean ADC differences ranged from negligible for phantom data to 2.8% for [Formula: see text] in vivo data. Some higher deviations were found for individual implementations and online parametric maps. Despite generally good concordance, implementation biases in ADC measures are sometimes significant and may be large enough to be of concern in multisite studies.

  3. 3D-quantitative structure-activity relationship study for the design of novel enterovirus A71 3C protease inhibitors.

    PubMed

    Nie, Quandeng; Xu, Xiaoyi; Zhang, Qi; Ma, Yuying; Yin, Zheng; Shang, Luqing

    2018-06-07

    A three-dimensional quantitative structure-activity relationships model of enterovirus A71 3C protease inhibitors was constructed in this study. The protein-ligand interaction fingerprint was analyzed to generate a pharmacophore model. A predictive and reliable three-dimensional quantitative structure-activity relationships model was built based on the Flexible Alignment of AutoGPA. Moreover, three novel compounds (I-III) were designed and evaluated for their biochemical activity against 3C protease and anti-enterovirus A71 activity in vitro. III exhibited excellent inhibitory activity (IC 50 =0.031 ± 0.005 μM, EC 50 =0.036 ± 0.007 μM). Thus, this study provides a useful quantitative structure-activity relationships model to develop potent inhibitors for enterovirus A71 3C protease. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Repeatability of shear wave elastography in liver fibrosis phantoms—Evaluation of five different systems

    PubMed Central

    2018-01-01

    This study aimed to assess and validate the repeatability and agreement of quantitative elastography of novel shear wave methods on four individual tissue-mimicking liver fibrosis phantoms with different known Young’s modulus. We used GE Logiq E9 2D-SWE, Philips iU22 ARFI (pSWE), Samsung TS80A SWE (pSWE), Hitachi Ascendus (SWM) and Transient Elastography (TE). Two individual investigators performed all measurements non-continued and in parallel. The methods were evaluated for inter- and intraobserver variability by intraclass correlation, coefficient of variation and limits of agreement using the median elastography value. All systems used in this study provided high repeatability in quantitative measurements in a liver fibrosis phantom and excellent inter- and intraclass correlations. All four elastography platforms showed excellent intra-and interobserver agreement (interclass correlation 0.981–1.000 and intraclass correlation 0.987–1.000) and no significant difference in mean elasticity measurements for all systems, except for TE on phantom 4. All four liver fibrosis phantoms could be differentiated by quantitative elastography, by all platforms (p<0.001). In the Bland-Altman analysis the differences in measurements were larger for the phantoms with higher Young’s modulus. All platforms had a coefficient of variation in the range 0.00–0.21 for all four phantoms, equivalent to low variance and high repeatability. PMID:29293527

  5. Laser Speckle Contrast Imaging of Cerebral Blood Flow

    PubMed Central

    Dunn, Andrew K.

    2011-01-01

    Laser speckle contrast imaging (LSCI) has emerged over the past decade as a powerful, yet simple, method for imaging of blood flow dynamics in real time. The rapid adoption of LSCI for physiological studies is due to the relative ease and low cost of building an instrument as well as the ability to quantify blood flow changes with excellent spatial and temporal resolution. Although measurements are limited to superficial tissues with no depth resolution, LSCI has been instrumental in pre-clinical studies of neurological disorders as well as clinical applications including dermatological, neurosurgical and endoscopic studies. Recently a number of technical advances have been developed to improve the quantitative accuracy and temporal resolution of speckle imaging. This article reviews some of these recent advances and describes several applications of speckle imaging. PMID:22109805

  6. Efficient synthesis of methylene exo-glycals: another use of glycosylthiomethyl chlorides.

    PubMed

    Zhu, Xiangming; Jin, Ying; Wickham, John

    2007-03-30

    A new approach to the synthesis of methylene exo-glycals is described. Oxidation of glycosylthiolmethyl chloride (GTM-Cl) with mCPBA afforded the corresponding glycosylchloromethyl sulfone in almost quantitative yield, which underwent KOtBu-induced Ramberg-Bäcklund rearrangement to furnish the desired methylene exo-glycal in excellent yield.

  7. Computer measurement of arterial disease

    NASA Technical Reports Server (NTRS)

    Armstrong, J.; Selzer, R. H.; Barndt, R.; Blankenhorn, D. H.; Brooks, S.

    1980-01-01

    Image processing technique quantifies human atherosclerosis by computer analysis of arterial angiograms. X-ray film images are scanned and digitized, arterial shadow is tracked, and several quantitative measures of lumen irregularity are computed. In other tests, excellent agreement was found between computer evaluation of femoral angiograms on living subjects and evaluation by teams of trained angiographers.

  8. Creating and Working with Control Charts in Excel

    ERIC Educational Resources Information Center

    Schikora, Paul F.

    2017-01-01

    With the growth in distance education offerings, instructors who now teach quantitative material via the web have been faced with many challenges. Foremost has been the need to develop appropriate methods for teaching such material to students who are not physically in the classroom. Methodologies that have traditionally been taught in a highly…

  9. Teaching Critical Thinking Using High-Impact Practices: A Quantitative Study

    ERIC Educational Resources Information Center

    Rosfeld, Kimberlina

    2017-01-01

    Many American college students lack the academic skills to be successful. College faculty members struggle to help these disadvantaged students excel in a college environment. There is a need for identified strategies to help college students develop academic skills such as critical thinking. The purpose of this study was to determine if…

  10. Rural Schools in Developing Countries: A Case of Donon Manga in Eastern Tandjile in Chad

    ERIC Educational Resources Information Center

    Ndoutorlengar, Médard; Djangrang, Man-na; Mamgue, Bassinang; Yongsi, H. B. Nguendo; Groza, Octavian

    2014-01-01

    The schools in rural areas in developing countries are often confronted with difficulties which are, in general, related to poverty, the quantitative and qualitative insufficiency of the professionals and the organization. Consequently, every year, the examinations results are unsatisfactory playing on the curriculum and excellence in the…

  11. Light-propagation management in coupled waveguide arrays: Quantitative experimental and theoretical assessment from band structures to functional patterns

    NASA Astrophysics Data System (ADS)

    Moison, Jean-Marie; Belabas, Nadia; Levenson, Juan Ariel; Minot, Christophe

    2012-09-01

    We assess the band structure of arrays of coupled optical waveguides both by ab initio calculations and by experiments, with an excellent quantitative agreement without any adjustable physical parameter. The band structures we obtain can deviate strongly from the expectations of the standard coupled mode theory approximation, but we describe them efficiently by a few parameters within an extended coupled mode theory. We also demonstrate that this description is in turn a firm and simple basis for accurate beam management in functional patterns of coupled waveguides, in full accordance with their design.

  12. Detection of brain tumor margins using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier

    2018-02-01

    In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, noncancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancerinfiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End-Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.

  13. Detection of brain tumor margins using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Juarez-Chambi, Ronald M.; Kut, Carmen; Rico-Jimenez, Jesus; Campos-Delgado, Daniel U.; Quinones-Hinojosa, Alfredo; Li, Xingde; Jo, Javier

    2018-02-01

    In brain cancer surgery, it is critical to achieve extensive resection without compromising adjacent healthy, non-cancerous regions. Various technological advances have made major contributions in imaging, including intraoperative magnetic imaging (MRI) and computed tomography (CT). However, these technologies have pros and cons in providing quantitative, real-time and three-dimensional (3D) continuous guidance in brain cancer detection. Optical Coherence Tomography (OCT) is a non-invasive, label-free, cost-effective technique capable of imaging tissue in three dimensions and real time. The purpose of this study is to reliably and efficiently discriminate between non-cancer and cancer-infiltrated brain regions using OCT images. To this end, a mathematical model for quantitative evaluation known as the Blind End- Member and Abundances Extraction method (BEAE). This BEAE method is a constrained optimization technique which extracts spatial information from volumetric OCT images. Using this novel method, we are able to discriminate between cancerous and non-cancerous tissues and using logistic regression as a classifier for automatic brain tumor margin detection. Using this technique, we are able to achieve excellent performance using an extensive cross-validation of the training dataset (sensitivity 92.91% and specificity 98.15%) and again using an independent, blinded validation dataset (sensitivity 92.91% and specificity 86.36%). In summary, BEAE is well-suited to differentiate brain tissue which could support the guiding surgery process for tissue resection.

  14. Micro-droplet Digital Polymerase Chain Reaction and Real-Time Quantitative Polymerase Chain Reaction Technologies Provide Highly Sensitive and Accurate Detection of Zika Virus.

    PubMed

    Hui, Yuan; Wu, Zhiming; Qin, Zhiran; Zhu, Li; Liang, Junhe; Li, Xujuan; Fu, Hanmin; Feng, Shiyu; Yu, Jianhai; He, Xiaoen; Lu, Weizhi; Xiao, Weiwei; Wu, Qinghua; Zhang, Bao; Zhao, Wei

    2018-06-01

    The establishment of highly sensitive diagnostic methods is critical in the early diagnosis and control of Zika virus (ZIKV) and in preventing serious neurological complications of ZIKV infection. In this study, we established micro-droplet digital polymerase chain reaction (ddPCR) and real-time quantitative PCR (RT-qPCR) protocols for the detection of ZIKV based on the amplification of the NS5 gene. For the ZIKV standard plasmid, the RT-qPCR results showed that the cycle threshold (Ct) value was linear from 10 1 to 10 8  copy/μL, with a standard curve R 2 of 0.999 and amplification efficiency of 92.203%; however, a concentration as low as 1 copy/μL could not be detected. In comparison with RT-qPCR, the ddPCR method resulted in a linear range of 10 1 -10 4  copy/μL and was able to detect concentrations as low as 1 copy/μL. Thus, for detecting ZIKV from clinical samples, RT-qPCR is a better choice for high-concentration samples (above 10 1  copy/μL), while ddPCR has excellent accuracy and sensitivity for low-concentration samples. These results indicate that the ddPCR method should be of considerable use in the early diagnosis, laboratory study, and monitoring of ZIKV.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, Ian M.; Collins, Aaron M.; Quintana, Hope A.

    In this study, we develop a quantitative dye dequenching technique for the measurement of polymersome fusion, using it to characterize the salt mediated, mechanically-induced fusion of polymersomes with polymer, lipid, and so-called stealth lipid vesicles. While dye dequenching has been used to quantitatively explore liposome fusion in the past, this is the first use of dye dequenching to measure polymersome fusion of which we are aware. In addition to providing quantitative results, dye dequenching is ideal for detecting fusion in instances where DLS results would be ambiguous, such as low yield levels and size ranges outside the capabilities of DLS.more » The dye chosen for this study was a cyanine derivative, 1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbocyanine iodide (DiR), which proved to provide excellent data on the extent of polymersome fusion. Using this technique, we have shown the limited fusion capabilities of polymersome/liposome heterofusion, notably DOPC vesicles fusing with polymersomes at half the efficiency of polymersome homofusion and DPPC vesicles showing virtually no fusion. In addition to these key heterofusion experiments, we determined the broad applicability of dye dequenching in measuring kinetic rates of polymersome fusion; and showed that even at elevated temperatures or over multiple weeks' time, no polymersome fusion occurred without agitation. Stealth liposomes formed from DPPC and PEO-functionalized lipid, however, fused with polymersomes and stealth liposomes with relatively high efficiency, lending support to our hypothesis that the response of the PEO corona to salt is a key factor in the fusion process. This last finding suggests that although the conjugation of PEO to lipids increases vesicle biocompatibility and enables their longer circulation times, it also renders the vesicles subject to destabilization under high salt and shear (e.g. in the circulatory system) that may lead to, in this case, fusion.« less

  16. Comportment and Communication Patterns among Hospitalist Physicians: Insight Gleaned Through Observation.

    PubMed

    Kotwal, Susrutha; Torok, Haruka; Khaliq, Waseem; Landis, Regina; Howell, Eric; Wright, Scott

    2015-08-01

    By 2014, there were more than 40,000 hospitalists delivering the majority of inpatient care in US hospitals. No empiric research has characterized hospitalist comportment and communication patterns as they care for patients. The chiefs of hospital medicine at five different hospitals were asked to identify their best hospitalists. These hospitalists were watched during their routine clinical care of patients. An observation tool was developed that focused on elements believed to be associated with excellent comportment and communication. One observer watched the physicians, taking detailed quantitative and qualitative field notes. A total of 26 hospitalists were shadowed. The mean age of the physicians was 38 years, and their average experience in hospital medicine was 6 years. The hospitalists were observed for a mean of 5 hours, during which time they saw an average of 7 patients (patient encounters observed N = 181). Physicians spent an average of 11 minutes with each patient. There was large variation in the extent to which desirable behaviors were performed. For example, most physicians (76%) started encounters with an open-ended question, and relatively few (30%) attempted to integrate nonmedical content into conversation with patients. This study represents a first step in trying to characterize comportment and communication in hospital medicine. Because hospitalists spend only a small proportion of their clinical time in direct patient care, it is imperative that excellent comportment and communication are clearly defined and established as a goal for every encounter.

  17. Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: Effects on image quality, artefacts and diagnostic performance for the detection of stenosis.

    PubMed

    Leithner, Doris; Mahmoudi, Scherwin; Wichmann, Julian L; Martin, Simon S; Lenga, Lukas; Albrecht, Moritz H; Booz, Christian; Arendt, Christophe T; Beeres, Martin; D'Angelo, Tommaso; Bodelle, Boris; Vogl, Thomas J; Scholtz, Jan-Erik

    2018-02-01

    To investigate the impact of traditional (VMI) and noise-optimized virtual monoenergetic imaging (VMI+) algorithms on quantitative and qualitative image quality, and the assessment of stenosis in carotid and intracranial dual-energy CTA (DE-CTA). DE-CTA studies of 40 patients performed on a third-generation 192-slice dual-source CT scanner were included in this retrospective study. 120-kVp image-equivalent linearly-blended, VMI and VMI+ series were reconstructed. Quantitative analysis included evaluation of contrast-to-noise ratios (CNR) of the aorta, common carotid artery, internal carotid artery, middle cerebral artery, and basilar artery. VMI and VMI+ with highest CNR, and linearly-blended series were rated qualitatively. Three radiologists assessed artefacts and suitability for evaluation at shoulder height, carotid bifurcation, siphon, and intracranial using 5-point Likert scales. Detection and grading of stenosis were performed at carotid bifurcation and siphon. Highest CNR values were observed for 40-keV VMI+ compared to 65-keV VMI and linearly-blended images (P < 0.001). Artefacts were low in all qualitatively assessed series with excellent suitability for supraaortic artery evaluation at shoulder and bifurcation height. Suitability was significantly higher in VMI+ and VMI compared to linearly-blended images for intracranial and ICA assessment (P < 0.002). VMI and VMI+ showed excellent accordance for detection and grading of stenosis at carotid bifurcation and siphon with no differences in diagnostic performance. 40-keV VMI+ showed improved quantitative image quality compared to 65-keV VMI and linearly-blended series in supraaortic DE-CTA. VMI and VMI+ provided increased suitability for carotid and intracranial artery evaluation with excellent assessment of stenosis, but did not translate into increased diagnostic performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Analysis of facility needs level in architecture studio for students’ studio grades

    NASA Astrophysics Data System (ADS)

    Lubis, A. S.; Hamid, B.; Pane, I. F.; Marpaung, B. O. Y.

    2018-03-01

    Architects must be able to play an active role and contribute to the realization of a sustainable environment. Architectural education has inherited many education research used qualitative and quantitative methods. The data were gathered by conducting (a) observation,(b) interviews, (c) documentation, (d) literature study, and (e) Questionnaire. The gathered data were analyzed qualitatively to find out what equipment needed in the learning process in the Architecture Studio, USU. Questionnaires and Ms. Excel were used for the quantitative analysis. The tabulation of quantitative data would be correlated with the students’ studio grades. The result of the research showed that equipment with the highest level of needs was (1) drawing table, (2) Special room for each student, (3) Internet Network, (4) Air Conditioning, (5) Sufficient lighting.

  19. Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.

    PubMed

    Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark

    2017-12-01

    The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and the parametric PET-MR images were excellent. TOF and reconstruction settings had little impact on MBF values.

  20. California in a Time of Excellence: School Reform at the Crossroads of the American Dream

    ERIC Educational Resources Information Center

    LaSpina, James Andrew

    2009-01-01

    "California in a Time of Excellence" follows the Golden State's efforts to reform its public school system from 1983 to the present. Beginning with progressive curriculum reform initiatives that were launched even before the National Commission on Excellence in Education (NCEE) issued "A Nation at Risk" in 1983, James Andrew…

  1. MO-C-BRB-00: President’s Symposium: Revitalizing Scientific Excellence: Turning Research Into Clinical Reality Through Translational Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, andmore » the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.« less

  2. Diffusion-weighted imaging of the prostate: should we use quantitative metrics to better characterize focal lesions originating in the peripheral zone?

    PubMed

    Pierre, Thibaut; Cornud, Francois; Colléter, Loïc; Beuvon, Frédéric; Foissac, Frantz; Delongchamps, Nicolas B; Legmann, Paul

    2018-05-01

    To compare inter-reader concordance and accuracy of qualitative diffusion-weighted (DW) PIRADSv2.0 score with those of quantitative DW-MRI for the diagnosis of peripheral zone prostate cancer. Two radiologists independently assigned a DW-MRI-PIRADS score to 92 PZ-foci, in 74 patients (64.3±5.6 years old; median PSA level: 8 ng/ml, normal DRE in 70 men). A standardised ADCmean and nine ADC-derived parameters were measured, including ADCratios with the whole-prostate (WP-ADCratio) or the mirror-PZ (mirror-ADCratio) as reference areas. Surgical histology and MRI-TRUS fusion-biopsy were the reference for tumours and benign foci, respectively. Inter-reader agreement was assessed by the Cohen-kappa-coefficient and the intraclass correlation coefficient (ICC). Univariate-multivariate regressions determined the most predictive factor for cancer. Fifty lesions were malignant. Inter-reader concordance was fair for qualitative assessment, but excellent for quantitative assessment for all quantitative variables. At univariate analysis, ADCmean, WP-ADCratio and WL-ADCmean performed equally, but significantly better than the mirror-ADCratio (p<0.001). At multivariate analysis, the only independent variable significantly associated with malignancy was the whole-prostate-ADCratio. At a cut-off value of 0.68, sensitivity was 94-90 % and specificity was 60-38 % for readers 1 and 2, respectively. The whole-prostate-ADCratio improved the qualitative inter-reader concordance and characterisation of focal PZ-lesions. • Inter-reader concordance of DW PI-RADSv2.0 score for PZ lesions was only fair. • Using a standardised ADCmean measurement and derived DW-quantitative parameters, concordance was excellent. • The whole-prostate ADCratio performed significantly better than the mirror-ADCratio for cancer detection. • At a cut-off of 0.68, sensitivity values of WP-ADCratio were 94-90 %. • The whole-prostate ADCratio may circumvent variations of ADC metrics across centres.

  3. Prognostic significance of normal quantitative Tl-201 stress scintigraphy in relation to pretest likelihood of coronary artery disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, D.J.; Russo, D.; Clements, J.

    A previous study reported an excellent prognosis and low cardiac event rate in patients(pts) with chest pain and normal quantitative T1-201 scintigraphy(SC). Such result would not be unexpected if the population under study had a predominance of pts with low pre-T1-201 likelihood(L) of significant coronary artery disease (CAD). Hence, the authors undertook telephone follow-up in pts with chest pain syndrome and normal quantitative T1-201 exercise SC, and related outcome to pretest L of CAD. Pretest L was determined by serial L analysis on the basis of: symptoms, age, sex, and exercise ECG. All pts had T1-201 SC immediately post exercisemore » and 2 hrs later. After interpolative background correction, circumferential count and washout profiles were generated. All pts had unequivocally normal studies. Of a total of 96 pts studied in 1981-82, 20 pts were lost to follow-up. Of the remaining 76 pts, 45 were males and 31 females. The pretest L of CAD had an inverted Gaussian distribution: thirty-four pts(47%) had <33% L of CAD, 3 pts (5%) had 33-66% L of CAD, and 35 pts(48%) had >66% L of CAD. Mean follow-up was 22+- 3 months. No deaths occurred. Two pts(3%) (with pretest L of 54% and 94%) had myocardial infarctions, 8 and 22 months respectively after T1-201 stress SC. One pt underwent percutaneous transluminal coronary angioplasty (PTCA) 16 months after T1-201 stress SC. These findings confirm excellent prognostic significance of normal quantitative T1-201 stress scintigraphy.« less

  4. Novel Technique for Quantitative Fast Scanning Calorimetry on Electrospun Fibers

    NASA Astrophysics Data System (ADS)

    Thomas, David; Govinna, Nelaka; Schick, Christoph; Cebe, Peggy

    Fast scanning chip calorimetry allows for the study of polymers which have rapid nucleation and/or crystallization kinetics, or degrade within their melting range. Heating rates used, up to 4000 K/s, allow studies of hetero and homogeneous nucleation at time scales inaccessible with conventional calorimeters, whose rates are typically <0.5 K/s. Polyethylene terephthalate (PET) and polyvinyl alcohol (PVA) were chosen in the development of a new methodology to obtain quantitative fast scanning thermal data from electrospun nanofibers using a Flash DSC1. The structure of nanofibers requires special methods to load nanogram-sized samples onto a UFSC1 sensor. Fibers were directly spun onto TEM grids which provide a durable substrate to support bundles of nanofibers and possess excellent thermal conductivity allowing for a strong, repeatable signal and ensure good sample to sensor contact. As spun samples were held isothermally at temperatures ranging from Tg to Tm then heated at 2,000 K/s to assess as-spun crystallinity and cold crystallization behaviors. Above Tm the fibers break up into micro- and nano-droplets. On these samples, melt crystallization experiments were performed to study nucleation and crystallization of polymer confined to nanodroplet morphology. NSF DMR-1608125.

  5. Quantitative high-performance liquid chromatography of nucleosides in biological materials.

    PubMed

    Gehrke, C W; Kuo, K C; Davis, G E; Suits, R D; Waalkes, T P; Borek, E

    1978-03-21

    A rigorous, comprehensive, and reliable reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the analysis of ribonucleosides in urine (psi, m1A, m1I, m2G, A, m2(2)G). An initial isolation of ribonucleosides with an affinity gel containing an immobilized phenylboronic acid was used to improve selectivity and sensitivity. Response for all nucleosides was linear from 0.1 to 50 nmoles injected and good quantitation was obtained for 25 microliter or less of sample placed on the HPLC column. Excellent precision of analysis for urinary nucleosides was achieved on matrix dependent and independent samples, and the high resolution of the reversed-phase column allowed the complete separation of 9 nucleosides from other unidentified UV absorbing components at the 1-ng level. Supporting experimental data are presented on precision, recovery, chromatographic methods, minimum detection limit, retention time, relative molar response, sample clean-up, stability of nucleosides, boronate gel capacity, and application to analysis of urine from patients with leukemia and breast cancer. This method is now being used routinely for the determination of the concentration and ratios of nucleosides in urine from patients with different types of cancer and in chemotherapy response studies.

  6. Determination of Detection Limits and Quantitation Limits for Compounds in a Database of GC/MS by FUMI Theory

    PubMed Central

    Nakashima, Shinya; Hayashi, Yuzuru

    2016-01-01

    The aim of this paper is to propose a stochastic method for estimating the detection limits (DLs) and quantitation limits (QLs) of compounds registered in a database of a GC/MS system and prove its validity with experiments. The approach described in ISO 11843 Part 7 is adopted here as an estimation means of DL and QL, and the decafluorotriphenylphosphine (DFTPP) tuning and retention time locking are carried out for adjusting the system. Coupled with the data obtained from the system adjustment experiments, the information (noise and signal of chromatograms and calibration curves) stored in the database is used for the stochastic estimation, dispensing with the repetition measurements. Of sixty-six pesticides, the DL values obtained by the ISO method were compared with those from the statistical approach and the correlation between them was observed to be excellent with the correlation coefficient of 0.865. The accuracy of the method proposed was also examined and concluded to be satisfactory as well. The samples used are commercial products of pesticides mixtures and the uncertainty from sample preparation processes is not taken into account. PMID:27162706

  7. Quantitative liquid chromatographic determination of bromadoline and its N-demethylated metabolites in blood, plasma, serum, and urine samples.

    PubMed

    Peng, G W; Sood, V K; Rykert, U M

    1985-03-01

    Bromadoline and its two N-demethylated metabolites were extracted into ether:butyl chloride after the addition of internal standard and basification of the various biological fluids (blood, plasma, serum, and urine). These compounds were then extracted into dilute phosphoric acid from the organic phase and separated on a reversed-phase chromatographic system using a mobile phase containing acetonitrile and a buffer of 1,4-dimethylpiperazine and perchloric acid. The overall absolute extraction recoveries of these compounds were approximately 50-80%. The background interferences from the biological fluids were negligible and allowed quantitative determination of bromadoline and the metabolites at levels as low as 2-5 ng/mL. At mobile phase flow rate of 1 mL/min, the sample components and the internal standard were eluted at the retention times within approximately 7-12 min. The drug- and metabolite-to-internal standard peak height ratios showed excellent linear relationships with their corresponding concentrations. The analytical method showed satisfactory within- and between-run assay precision and accuracy, and has been utilized in the simultaneous determination of bromadoline and its two N-demethylated metabolites in biological fluids collected from humans and from dogs after administration of bromadoline maleate.

  8. Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevcik, R. S.; Hyman, D. A.; Basumallich, L.

    2013-01-01

    A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymaticmore » saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.« less

  9. The state of everyday quantitative EEG use in Canada: A national technologist survey.

    PubMed

    Ng, Marcus C; Gillis, Kara

    2017-07-01

    This study sought to determine the state of quantitative EEG (QEEG) use in Canada, as QEEG may provide a partial solution to the issue of escalating EEG demand against insufficient health care resources. A 10-item survey questionnaire was administered to participants at the annual meeting of the Canadian Association of Electroneurophysiology Technologists, which was held in parallel with the annual meeting of the Canadian Neurological Sciences Federation. At least 70% of the Canadian population has QEEG access through academic medical institutions with applicability to adults and children. QEEG was clinically used 50% in real-time and 50% retrospectively in the critical care and epilepsy monitoring units for long-term monitoring and automated seizure detection. QEEG trend use, montage use, and duration were variable. To cope with insufficient health care resources, QEEG is in surprisingly frequent clinical use across Canada. There is no consensus on optimal QEEG trends and montages. The relative ubiquity of QEEG affords an excellent opportunity for research as increasing EEG demand outpaces dwindling health care resources into the foreseeable future. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  10. Optimal design of waveform digitisers for both energy resolution and pulse shape discrimination

    NASA Astrophysics Data System (ADS)

    Cang, Jirong; Xue, Tao; Zeng, Ming; Zeng, Zhi; Ma, Hao; Cheng, Jianping; Liu, Yinong

    2018-04-01

    Fast digitisers and digital pulse processing have been widely used for spectral application and pulse shape discrimination (PSD) owing to their advantages in terms of compactness, higher trigger rates, offline analysis, etc. Meanwhile, the noise of readout electronics is usually trivial for organic, plastic, or liquid scintillator with PSD ability because of their poor intrinsic energy resolution. However, LaBr3(Ce) has been widely used for its excellent energy resolution and has been proven to have PSD ability for alpha/gamma particles. Therefore, designing a digital acquisition system for such scintillators as LaBr3(Ce) with both optimal energy resolution and promising PSD ability is worthwhile. Several experimental research studies about the choice of digitiser properties for liquid scintillators have already been conducted in terms of the sampling rate and vertical resolution. Quantitative analysis on the influence of waveform digitisers, that is, fast amplifier (optional), sampling rates, and vertical resolution, on both applications is still lacking. The present paper provides quantitative analysis of these factors and, hence, general rules about the optimal design of digitisers for both energy resolution and PSD application according to the noise analysis of time-variant gated charge integration.

  11. In situ transmission electron microscopy of lead dendrites and lead ions in aqueous solution.

    PubMed

    White, Edward R; Singer, Scott B; Augustyn, Veronica; Hubbard, William A; Mecklenburg, Matthew; Dunn, Bruce; Regan, Brian C

    2012-07-24

    An ideal technique for observing nanoscale assembly would provide atomic-resolution images of both the products and the reactants in real time. Using a transmission electron microscope we image in situ the electrochemical deposition of lead from an aqueous solution of lead(II) nitrate. Both the lead deposits and the local Pb(2+) concentration can be visualized. Depending on the rate of potential change and the potential history, lead deposits on the cathode in a structurally compact layer or in dendrites. In both cases the deposits can be removed and the process repeated. Asperities that persist through many plating and stripping cycles consistently nucleate larger dendrites. Quantitative digital image analysis reveals excellent correlation between changes in the Pb(2+) concentration, the rate of lead deposition, and the current passed by the electrochemical cell. Real-time electron microscopy of dendritic growth dynamics and the associated local ionic concentrations can provide new insight into the functional electrochemistry of batteries and related energy storage technologies.

  12. Determination of the Earth's Plasmapause Location from the CE-3 EUVC Images

    NASA Technical Reports Server (NTRS)

    He, Fei; Zhang, Xiao-Xin; Chen, Bo; Fok, Mei-Ching; Nakano, Shinya

    2016-01-01

    The Moon-based Extreme Ultraviolet Camera (EUVC) aboard China's Chang'e-3 (CE-3) mission has successfully imaged the entire Earth's plasmasphere for the first time from the side views on lunar surface. An EUVC image on 21 April 2014 is used in this study to demonstrate the characteristics and configurations of the Moon-based EUV imaging and to illustrate the determination algorithm of the plasmapause locations on the magnetic equator. The plasmapause locations determined from all the available EUVC images with the Minimum L Algorithm are quantitatively compared with those extracted from insitu observations (Defense Meteorological Satellite Program, Time History of Events and Macroscale Interactions during Substorms, and Radiation Belt Storm Probes). Excellent agreement between the determined plasmapauses seen by EUVC and the extracted ones from other satellites indicates the reliability of the Moon-based EUVC images as well as the determination algorithm. This preliminary study provides an important basis for future investigation of the dynamics of the plasmasphere with the Moon-based EUVC imaging.

  13. Modeling Fan Effects on the Time Course of Associative Recognition

    PubMed Central

    Schneider, Darryl W.; Anderson, John R.

    2011-01-01

    We investigated the time course of associative recognition using the response signal procedure, whereby a stimulus is presented and followed after a variable lag by a signal indicating that an immediate response is required. More specifically, we examined the effects of associative fan (the number of associations that an item has with other items in memory) on speed–accuracy tradeoff functions obtained in a previous response signal experiment involving briefly studied materials and in a new experiment involving well-learned materials. High fan lowered asymptotic accuracy or the rate of rise in accuracy across lags, or both. We developed an Adaptive Control of Thought–Rational (ACT-R) model for the response signal procedure to explain these effects. The model assumes that high fan results in weak associative activation that slows memory retrieval, thereby decreasing the probability that retrieval finishes in time and producing a speed–accuracy tradeoff function. The ACT-R model provided an excellent account of the data, yielding quantitative fits that were as good as those of the best descriptive model for response signal data. PMID:22197797

  14. Real-time probabilistic covariance tracking with efficient model update.

    PubMed

    Wu, Yi; Cheng, Jian; Wang, Jinqiao; Lu, Hanqing; Wang, Jun; Ling, Haibin; Blasch, Erik; Bai, Li

    2012-05-01

    The recently proposed covariance region descriptor has been proven robust and versatile for a modest computational cost. The covariance matrix enables efficient fusion of different types of features, where the spatial and statistical properties, as well as their correlation, are characterized. The similarity between two covariance descriptors is measured on Riemannian manifolds. Based on the same metric but with a probabilistic framework, we propose a novel tracking approach on Riemannian manifolds with a novel incremental covariance tensor learning (ICTL). To address the appearance variations, ICTL incrementally learns a low-dimensional covariance tensor representation and efficiently adapts online to appearance changes of the target with only O(1) computational complexity, resulting in a real-time performance. The covariance-based representation and the ICTL are then combined with the particle filter framework to allow better handling of background clutter, as well as the temporary occlusions. We test the proposed probabilistic ICTL tracker on numerous benchmark sequences involving different types of challenges including occlusions and variations in illumination, scale, and pose. The proposed approach demonstrates excellent real-time performance, both qualitatively and quantitatively, in comparison with several previously proposed trackers.

  15. Magnetic Interactions and the Method of Images: A Wealth of Educational Suggestions

    ERIC Educational Resources Information Center

    Bonanno, A.; Camarca, M.; Sapia, P.

    2011-01-01

    Under some conditions, the method of images (well known in electrostatics) may be implemented in magnetostatic problems too, giving an excellent example of the usefulness of formal analogies in the description of physical systems. In this paper, we develop a quantitative model for the magnetic interactions underlying the so-called Geomag[TM]…

  16. Prussian Blue Coated Electrode as a Sensor for Electroinactive Cations in Aqueous Solutions

    ERIC Educational Resources Information Center

    Byrd, Houston; Chapman, Blake E.; Talley, Christopher L.

    2013-01-01

    Prussian Blue (PB) is an excellent material as a sensor for electroinactive cations because of its electrochemical behavior and its zeolytic character. A simple 3-h laboratory designed for a quantitative analysis or an instrumental methods course is reported. This laboratory studies the transport of various cations into a PB-modified electrode…

  17. A leap forward in geographic scale for forest ectomycorrhizal fungi

    Treesearch

    Filipa Cox; Nadia Barsoum; Martin I. Bidartondo; Isabella Børja; Erik Lilleskov; Lars O. Nilsson; Pasi Rautio; Kath Tubby; Lars Vesterdal

    2010-01-01

    In this letter we propose a first large-scale assessment of mycorrhizas with a European-wide network of intensively monitored forest plots as a research platform. This effort would create a qualitative and quantitative shift in mycorrhizal research by delivering the first continental-scale map of mycorrhizal fungi. Readersmay note that several excellent detailed...

  18. The "Individualised Accounting Questions" Technique: Using Excel to Generate Quantitative Exercises for Large Classes with Unique Individual Answers

    ERIC Educational Resources Information Center

    Nnadi, Matthias; Rosser, Mike

    2014-01-01

    The "individualised accounting questions" (IAQ) technique set out in this paper encourages independent active learning. It enables tutors to set individualised accounting questions and construct an answer grid that can be used for any number of students, with numerical values for each student's answers based on their student enrolment…

  19. Technology and the study of wildfire: Middle school students study the impacts of wildfire

    USGS Publications Warehouse

    Fox-Gliessman, D.; Kerski, J.J.

    2005-01-01

    Various technologies that can assist students in exploring the human and environmental impacts of wildfire and in communicating their findings are discussed. Wildfires occur in many parts of the world, and provide an excellent opportunity for students to study local and global interdisciplinary issues using technology. Prior to the beginning of the field study, students take instructions in both their math and science classes about the distinction and appropriate uses of quantitative and qualitative data. Use of computer programs such as Excel spreadsheets which can contain data, and interaction of research and technology group with students, can help them collect best of the information and in making an accurate report.

  20. Quantitative PCR for HTLV-1 provirus in adult T-cell leukemia/lymphoma using paraffin tumor sections.

    PubMed

    Kato, Junki; Masaki, Ayako; Fujii, Keiichiro; Takino, Hisashi; Murase, Takayuki; Yonekura, Kentaro; Utsunomiya, Atae; Ishida, Takashi; Iida, Shinsuke; Inagaki, Hiroshi

    2016-11-01

    Detection of HTLV-1 provirus using paraffin tumor sections may assist the diagnosis of adult T-cell leukemia/lymphoma (ATLL). For the detection, non-quantitative PCR assay has been reported, but its usefulness and limitations remain unclear. To our knowledge, quantitative PCR assay using paraffin tumor sections has not been reported. Using paraffin sections from ATLLs and non-ATLL T-cell lymphomas, we first performed non-quantitative PCR for HTLV-1 provirus. Next, we determined tumor ratios and carried out quantitative PCR to obtain provirus copy numbers. The results were analyzed with a simple regression model and a novel criterion, cut-off using 95 % rejection limits. Our quantitative PCR assay showed an excellent association between tumor ratios and the copy numbers (r = 0.89, P < 0.0001). The 95 % rejection limits provided a statistical basis for the range for the determination of HTLV-1 involvement. Its application suggested that results of non-quantitative PCR assay should be interpreted very carefully and that our quantitative PCR assay is useful to estimate the status of HTLV-1 involvement in the tumor cases. In conclusion, our quantitative PCR assay using paraffin tumor sections may be useful for the screening of ATLL cases, especially in HTLV-1 non-endemic areas where easy access to serological testing for HTLV-1 infection is limited. © 2016 Japanese Society of Pathology and John Wiley & Sons Australia, Ltd.

  1. The use of quantitative real-time reverse transcriptase PCR for 5' and 3' portions of ALK transcripts to detect ALK rearrangements in lung cancers.

    PubMed

    Wang, Rui; Pan, Yunjian; Li, Chenguang; Hu, Haichuan; Zhang, Yang; Li, Hang; Luo, Xiaoyang; Zhang, Jie; Fang, Zhaoyuan; Li, Yuan; Shen, Lei; Ji, Hongbin; Garfield, David; Sun, Yihua; Chen, Haiquan

    2012-09-01

    Approximately 3% to 7% of non-small cell lung cancers (NSCLC) harbor an ALK fusion gene, thus defining a tumor group that may be responsive to targeted therapy. The breakpoint in ALK consistently occurs at exon 20 and EML4 or other fusion partners, thus driving a strong expression of ALK kinase domain and resulting in an unbalanced expression in 5' and 3' portions of ALK transcripts. We have developed a rapid and accurate method by simultaneously detecting the expression in 5' and 3' portions of ALK mRNA. Quantitative real-time reverse transcriptase PCR (qRT-PCR) was used to examine expression levels of the 5' and 3' portions of ALK transcripts in177 NSCLCs, in which EGFR, KRAS, HER2, and BRAF mutations were absent. If unbalanced ALK mRNA expression was seen, ALK rearrangement was assumed to exist. ALK FISH was used to confirm the accuracy of qRT-PCR. RT-PCR and 5' RACE coupling sequencing identified the fusion variants. Real-time RT-PCR showed excellent sensitivity and specificity (100% and 100%, respectively) for detection of ALK rearrangements in resected specimens. In addition, six novel ALK fusion variants were identified, including one KIF5B-ALK (E17;A20) and five EML4-ALK variants (E6a;A19, E6a/b ins 18;A20, E17b ins 39;A20, E10a/b, E13;A20, and E17 ins 65;A20). Real-time RT-PCR is a rapid and accurate method for diagnosing ALK-rearranged lung cancers. Coupling of 5' RACE to this method should further facilitate rapid identification of novel ALK fusion genes. ©2012 AACR.

  2. Rapid screening and determination of 11 new psychoactive substances by direct analysis in real time mass spectrometry and liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Nie, Honggang; Li, Xianjiang; Hua, Zhendong; Pan, Wei; Bai, Yanping; Fu, Xiaofang

    2016-08-01

    With the amounts and types of new psychoactive substances (NPSs) increasing rapidly in recent years, an excellent high-throughput method for the analysis of these compounds is urgently needed. In this article, a rapid screening method and a quantitative analysis method for 11 NPSs are described and compared, respectively. A simple direct analysis in real time mass spectrometry (DART-MS) method was developed for the analysis of 11 NPSs including three categories of these substances present on the global market such as four cathinones, one phenylethylamine, and six synthetic cannabinoids. In order to analyze these compounds quantitatively with better accuracy and sensitivity, another rapid analytical method with a low limit of detection (LOD) was also developed using liquid chromatography/electrospray ionization quadrupole time-of-flight mass spectrometry (LC/QTOFMS). The 11 NPSs could be determined within 0.5 min by DART-MS. Furthermore, they could also be separated and determined within 5 min by the LC/QTOFMS method. The two methods both showed good linearity with correlation coefficients (r(2) ) higher than 0.99. The LODs for all these target NPSs by DART-MS and LC/QTOFMS ranged from 5 to 40 ng mL(-1) and 0.1 to 1 ng mL(-1) , respectively. Confiscated samples, named as "music vanilla" and "bath salt", and 11 spiked samples were firstly screened by DART-MS and then determined by LC/QTOFMS. The identification of NPSs in confiscated materials was successfully achieved, and the proposed analytical methodology could offer rapid screening and accurate analysis results. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  3. USING MICROSOFT OFFICE EXCEL® 2007 TO CONDUCT GENERALIZED MATCHING ANALYSES

    PubMed Central

    Reed, Derek D

    2009-01-01

    The generalized matching equation is a robust and empirically supported means of analyzing relations between reinforcement and behavior. Unfortunately, no simple task analysis is available to behavior analysts interested in using the matching equation to evaluate data in clinical or applied settings. This technical article presents a task analysis for the use of Microsoft Excel to analyze and plot the generalized matching equation. Using a data-based case example and a step-by-step guide for completing the analysis, these instructions are intended to promote the use of quantitative analyses by researchers with little to no experience in quantitative analyses or the matching law. PMID:20514196

  4. Deformations and strains in adhesive joints by moire interferometry

    NASA Technical Reports Server (NTRS)

    Post, D.; Czarnek, R.; Wood, J.; John, D.; Lubowinski, S.

    1984-01-01

    Displacement fields in a thick adherend lap joint and a cracked lap shear specimen were measured by high sensitivity moire interferometry. Contour maps of in-plane U and V displacements were obtained across adhesive and adherent surfaces. Loading sequences ranged from modest loads to near-failure loads. Quantitative results are given for displacements and certain strains in the adhesive and along the adhesive/adherend boundary lines. The results show nonlinear displacements and strains as a function of loads or stresses and they show viscoelastic or time-dependent response. Moire interferometry is an excellent method for experimental studies of adhesive joint performance. Subwavelength displacement resolution of a few micro-inches, and spatial resolution corresponding to 1600 fringes/inch (64 fringes/mm), were obtained in these studies. The whole-field contour maps offer insights not available from local measurements made by high sensitivity gages.

  5. Femtosecond nonlinear ultrasonics in gold probed with ultrashort surface plasmons.

    PubMed

    Temnov, Vasily V; Klieber, Christoph; Nelson, Keith A; Thomay, Tim; Knittel, Vanessa; Leitenstorfer, Alfred; Makarov, Denys; Albrecht, Manfred; Bratschitsch, Rudolf

    2013-01-01

    Fundamental interactions induced by lattice vibrations on ultrafast time scales have become increasingly important for modern nanoscience and technology. Experimental access to the physical properties of acoustic phonons in the terahertz-frequency range and over the entire Brillouin zone is crucial for understanding electric and thermal transport in solids and their compounds. Here we report on the generation and nonlinear propagation of giant (1 per cent) acoustic strain pulses in hybrid gold/cobalt bilayer structures probed with ultrafast surface plasmon interferometry. This new technique allows for unambiguous characterization of arbitrary ultrafast acoustic transients. The giant acoustic pulses experience substantial nonlinear reshaping after a propagation distance of only 100 nm in a crystalline gold layer. Excellent agreement with the Korteveg-de Vries model points to future quantitative nonlinear femtosecond terahertz-ultrasonics at the nano-scale in metals at room temperature.

  6. Anomalous critical slowdown at a first order phase transition in single polymer chains.

    PubMed

    Zhang, Shuangshuang; Qi, Shuanhu; Klushin, Leonid I; Skvortsov, Alexander M; Yan, Dadong; Schmid, Friederike

    2017-08-14

    Using Brownian dynamics, we study the dynamical behavior of a polymer grafted onto an adhesive surface close to the mechanically induced adsorption-stretching transition. Even though the transition is first order (in the infinite chain length limit, the stretching degree of the chain jumps discontinuously), the characteristic relaxation time is found to grow according to a power law as the transition point is approached. We present a dynamic effective interface model which reproduces these observations and provides an excellent quantitative description of the simulation data. The generic nature of the theoretical model suggests that the unconventional mixing of features that are characteristic for first-order transitions (a jump in an order parameter) and features that are characteristic of critical points (an anomalous slowdown) may be a common phenomenon in force-driven phase transitions of macromolecules.

  7. MRI tools for assessment of microstructure and nephron function of the kidney.

    PubMed

    Xie, Luke; Bennett, Kevin M; Liu, Chunlei; Johnson, G Allan; Zhang, Jeff Lei; Lee, Vivian S

    2016-12-01

    MRI can provide excellent detail of renal structure and function. Recently, novel MR contrast mechanisms and imaging tools have been developed to evaluate microscopic kidney structures including the tubules and glomeruli. Quantitative MRI can assess local tubular function and is able to determine the concentrating mechanism of the kidney noninvasively in real time. Measuring single nephron function is now a near possibility. In parallel to advancing imaging techniques for kidney microstructure is a need to carefully understand the relationship between the local source of MRI contrast and the underlying physiological change. The development of these imaging markers can impact the accurate diagnosis and treatment of kidney disease. This study reviews the novel tools to examine kidney microstructure and local function and demonstrates the application of these methods in renal pathophysiology. Copyright © 2016 the American Physiological Society.

  8. Surface inspection using FTIR spectroscopy

    NASA Technical Reports Server (NTRS)

    Powell, G. L.; Smyrl, N. R.; Williams, D. M.; Meyers, H. M., III; Barber, T. E.; Marrero-Rivera, M.

    1995-01-01

    The use of reflectance Fourier transform infrared (FTIR) spectroscopy as a tool for surface inspection is described. Laboratory instruments and portable instruments can support remote sensing probes that can map chemical contaminants on surfaces with detection limits under the best of conditions in the sub-nanometer range, i.e.. near absolute cleanliness, excellent performance in the sub-micrometer range, and useful performance for films tens of microns thick. Examples of discovering and quantifying contamination such as mineral oils and greases, vegetable oils, and silicone oils on aluminum foil, galvanized sheet steel, smooth aluminum tubing, and sandblasted 7075 aluminum alloy and D6AC steel. The ability to map in time and space the distribution of oil stains on metals is demonstrated. Techniques associated with quantitatively applying oils to metals, subsequently verifying the application, and non-linear relationships between reflectance and the quantity oil are described.

  9. Experimental benchmark for an improved simulation of absolute soft-x-ray emission from polystyrene targets irradiated with the Nike laser.

    PubMed

    Weaver, J L; Busquet, M; Colombant, D G; Mostovych, A N; Feldman, U; Klapisch, M; Seely, J F; Brown, C; Holland, G

    2005-02-04

    Absolutely calibrated, time-resolved spectral intensity measurements of soft-x-ray emission (hnu approximately 0.1-1.0 keV) from laser-irradiated polystyrene targets are compared to radiation-hydrodynamic simulations that include our new postprocessor, Virtual Spectro. This new capability allows a unified, detailed treatment of atomic physics and radiative transfer in nonlocal thermodynamic equilibrium conditions for simple spectra from low-Z materials as well as complex spectra from high-Z materials. The excellent agreement (within a factor of approximately 1.5) demonstrates the powerful predictive capability of the codes for the complex conditions in the ablating plasma. A comparison to data with high spectral resolution (E/deltaE approximately 1000) emphasizes the importance of including radiation coupling in the quantitative simulation of emission spectra.

  10. Using mean duration and variation of procedure times to plan a list of surgical operations to fit into the scheduled list time.

    PubMed

    Pandit, Jaideep J; Tavare, Aniket

    2011-07-01

    It is important that a surgical list is planned to utilise as much of the scheduled time as possible while not over-running, because this can lead to cancellation of operations. We wished to assess whether, theoretically, the known duration of individual operations could be used quantitatively to predict the likely duration of the operating list. In a university hospital setting, we first assessed the extent to which the current ad-hoc method of operating list planning was able to match the scheduled operating list times for 153 consecutive historical lists. Using receiver operating curve analysis, we assessed the ability of an alternative method to predict operating list duration for the same operating lists. This method uses a simple formula: the sum of individual operation times and a pooled standard deviation of these times. We used the operating list duration estimated from this formula to generate a probability that the operating list would finish within its scheduled time. Finally, we applied the simple formula prospectively to 150 operating lists, 'shadowing' the current ad-hoc method, to confirm the predictive ability of the formula. The ad-hoc method was very poor at planning: 50% of historical operating lists were under-booked and 37% over-booked. In contrast, the simple formula predicted the correct outcome (under-run or over-run) for 76% of these operating lists. The calculated probability that a planned series of operations will over-run or under-run was found useful in developing an algorithm to adjust the planned cases optimally. In the prospective series, 65% of operating lists were over-booked and 10% were under-booked. The formula predicted the correct outcome for 84% of operating lists. A simple quantitative method of estimating operating list duration for a series of operations leads to an algorithm (readily created on an Excel spreadsheet, http://links.lww.com/EJA/A19) that can potentially improve operating list planning.

  11. Quantitative estimation of the high-intensity zone in the lumbar spine: comparison between the symptomatic and asymptomatic population.

    PubMed

    Liu, Chao; Cai, Hong-Xin; Zhang, Jian-Feng; Ma, Jian-Jun; Lu, Yin-Jiang; Fan, Shun-Wu

    2014-03-01

    The high-intensity zone (HIZ) on magnetic resonance imaging (MRI) has been studied for more than 20 years, but its diagnostic value in low back pain (LBP) is limited by the high incidence in asymptomatic subjects. Little effort has been made to improve the objective assessment of HIZ. To develop quantitative measurements for HIZ and estimate intra- and interobserver reliability and to clarify different signal intensity of HIZ in patients with or without LBP. A measurement reliability and prospective comparative study. A consecutive series of patients with LBP between June 2010 and May 2011 (group A) and a successive series of asymptomatic controls during the same period (group B). Incidence of HIZ; quantitative measures, including area of disc, area and signal intensity of HIZ, and magnetic resonance imaging index; and intraclass correlation coefficients (ICCs) for intra- and interobserver reliability. On the basis of HIZ criteria, a series of quantitative dimension and signal intensity measures was developed for assessing HIZ. Two experienced spine surgeons traced the region of interest twice within 4 weeks for assessment of the intra- and interobserver reliability. The quantitative variables were compared between groups A and B. There were 72 patients with LBP and 79 asymptomatic controls enrolling in this study. The prevalence of HIZ in group A and group B was 45.8% and 20.2%, respectively. The intraobserver agreement was excellent for the quantitative measures (ICC=0.838-0.977) as well as interobserver reliability (ICC=0.809-0.935). The mean signal of HIZ in group A was significantly brighter than in group B (57.55±14.04% vs. 45.61±7.22%, p=.000). There was no statistical difference of area of disc and HIZ between the two groups. The magnetic resonance imaging index was found to be higher in group A when compared with group B (3.94±1.71 vs. 3.06±1.50), but with a p value of .050. A series of quantitative measurements for HIZ was established and demonstrated excellent intra- and interobserver reliability. The signal intensity of HIZ was different in patients with or without LBP, and significant brighter signal was observed in symptomatic subjects. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. HIFI-C: a robust and fast method for determining NMR couplings from adaptive 3D to 2D projections.

    PubMed

    Cornilescu, Gabriel; Bahrami, Arash; Tonelli, Marco; Markley, John L; Eghbalnia, Hamid R

    2007-08-01

    We describe a novel method for the robust, rapid, and reliable determination of J couplings in multi-dimensional NMR coupling data, including small couplings from larger proteins. The method, "High-resolution Iterative Frequency Identification of Couplings" (HIFI-C) is an extension of the adaptive and intelligent data collection approach introduced earlier in HIFI-NMR. HIFI-C collects one or more optimally tilted two-dimensional (2D) planes of a 3D experiment, identifies peaks, and determines couplings with high resolution and precision. The HIFI-C approach, demonstrated here for the 3D quantitative J method, offers vital features that advance the goal of rapid and robust collection of NMR coupling data. (1) Tilted plane residual dipolar couplings (RDC) data are collected adaptively in order to offer an intelligent trade off between data collection time and accuracy. (2) Data from independent planes can provide a statistical measure of reliability for each measured coupling. (3) Fast data collection enables measurements in cases where sample stability is a limiting factor (for example in the presence of an orienting medium required for residual dipolar coupling measurements). (4) For samples that are stable, or in experiments involving relatively stronger couplings, robust data collection enables more reliable determinations of couplings in shorter time, particularly for larger biomolecules. As a proof of principle, we have applied the HIFI-C approach to the 3D quantitative J experiment to determine N-C' RDC values for three proteins ranging from 56 to 159 residues (including a homodimer with 111 residues in each subunit). A number of factors influence the robustness and speed of data collection. These factors include the size of the protein, the experimental set up, and the coupling being measured, among others. To exhibit a lower bound on robustness and the potential for time saving, the measurement of dipolar couplings for the N-C' vector represents a realistic "worst case analysis". These couplings are among the smallest currently measured, and their determination in both isotropic and anisotropic media demands the highest measurement precision. The new approach yielded excellent quantitative agreement with values determined independently by the conventional 3D quantitative J NMR method (in cases where sample stability in oriented media permitted these measurements) but with a factor of 2-5 in time savings. The statistical measure of reliability, measuring the quality of each RDC value, offers valuable adjunct information even in cases where modest time savings may be realized.

  13. Improved diagnosis of pulmonary emphysema using in vivo dark-field radiography.

    PubMed

    Meinel, Felix G; Yaroshenko, Andre; Hellbach, Katharina; Bech, Martin; Müller, Mark; Velroyen, Astrid; Bamberg, Fabian; Eickelberg, Oliver; Nikolaou, Konstantin; Reiser, Maximilian F; Pfeiffer, Franz; Yildirim, Ali Ö

    2014-10-01

    The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancreatic elastase and confirmed by in vivo pulmonary function tests, histopathology, and quantitative morphometry. The mice were anesthetized but breathing freely during imaging. Experiments were performed using a prototype small-animal x-ray dark-field scanner that was operated at 35 kilovolt (peak) with an exposure time of 5 seconds for each of the 10 grating steps. Images were compared visually. For quantitative comparison of signal characteristics, regions of interest were placed in the upper, middle, and lower zones of each lung. Receiver-operating-characteristic statistics were performed to compare the effectiveness of transmission and dark-field signal intensities and the combined parameter "normalized scatter" to differentiate between healthy and emphysematous lungs. A clear visual difference between healthy and emphysematous mice was found for the dark-field images. Quantitative measurements of x-ray dark-field signal and normalized scatter were significantly different between the mice with pulmonary emphysema and the control mice and showed good agreement with pulmonary function tests and quantitative histology. The normalized scatter showed a significantly higher discriminatory power (area under the receiver-operating-characteristic curve [AUC], 0.99) than dark-field (AUC, 0.90; P = 0.01) or transmission signal (AUC, 0.69; P < 0.001) alone did, allowing for an excellent discrimination of healthy and emphysematous lung regions. In a murine model, x-ray dark-field radiography is technically feasible in vivo and represents a substantial improvement over conventional transmission-based x-ray imaging for the diagnosis of pulmonary emphysema.

  14. Real-time monitoring of human blood clotting using a lateral excited film bulk acoustic resonator

    NASA Astrophysics Data System (ADS)

    Chen, Da; Wang, Jingjng; Wang, Peng; Guo, Qiuquan; Zhang, Zhen; Ma, Jilong

    2017-04-01

    Frequent assay of hemostatic status is an essential issue for the millions of patients using anticoagulant drugs. In this paper, we presented a micro-fabricated film bulk acoustic sensor for the real-time monitoring of blood clotting and the measurement of hemostatic parameters. The device was made of an Au/ZnO/Si3N4 film stack and excited by a lateral electric field. It operated under a shear mode resonance with the frequency of 1.42 GHz and had a quality factor of 342 in human blood. During the clotting process of blood, the resonant frequency decreased along with the change of blood viscosity and showed an apparent step-ladder curve, revealing the sequential clotting stages. An important hemostatic parameter, prothrombin time, was quantitatively determined from the frequency response for different dilutions of the blood samples. The effect of a typical anticoagulant drug (heparin) on the prothrombin time was exemplarily shown. The proposed sensor displayed a good consistency and clinical comparability with the standard coagulometric methods. Thanks to the availability of direct digital signals, excellent potentials of miniaturization and integration, the proposed sensor has promising application for point-of-care coagulation technologies.

  15. Measurement of the perfusion fraction in brain tumors with intravoxel incoherent motion MR imaging: validation with histopathological vascular density in meningiomas.

    PubMed

    Togao, Osamu; Hiwatashi, Akio; Yamashita, Koji; Kikuchi, Kazufumi; Momosaka, Daichi; Yoshimoto, Koji; Kuga, Daisuke; Mizoguchi, Masahiro; Suzuki, Satoshi O; Iwaki, Toru; Van Cauteren, Marc; Iihara, Koji; Honda, Hiroshi

    2018-05-01

    To evaluate the quantification performance of the perfusion fraction (f) measured with intravoxel incoherent motion (IVIM) MR imaging in a comparison with the histological vascular density in meningiomas. 29 consecutive patients with meningioma (59.0 ± 16.8 years old, 8 males and 21 females) who underwent a subsequent surgical resection were examined with both IVIM imaging and a histopathological analysis. IVIM imaging was conducted using a single-shot SE-EPI sequence with 13 b-factors (0, 10, 20, 30, 50, 80, 100, 200, 300, 400, 600, 800, 1000 s mm - 2 ) at 3T. The perfusion fraction (f) was calculated by fitting the IVIM bi-exponential model. The 90-percentile f-value in the tumor region-of-interest (ROI) was defined as the maximum f-value (f-max). Histopathological vascular density (%Vessel) was measured on CD31-immunostainted histopathological specimens. The correlation and agreement between the f-values and %Vessel was assessed. The f-max (15.5 ± 5.5%) showed excellent agreement [intraclass correlation coefficient (ICC) = 0.754] and a significant correlation (r = 0.69, p < 0.0001) with the %Vessel (12.9 ± 9.4%) of the tumors. The Bland-Altman plot analysis showed excellent agreement between the f-max and %Vessel (bias, -2.6%; 95% limits of agreement, from -16.0 to 10.8%). The f-max was not significantly different among the histological subtypes of meningioma. An excellent agreement and a significant correlation were observed between the f-values and %Vessel. The f-value can be used as a noninvasive quantitative imaging measure to directly assess the vascular volume fraction in brain tumors. Advances in knowledge: The f-value measured by IVIM imaging showed a significant correlation and an excellent agreement with the histological vascular density in the meningiomas. The f-value can be used as a noninvasive and quantitative imaging measure to directly assess the volume fraction of capillaries in brain tumors.

  16. Advances in Surface Plasmon Resonance Imaging allowing for quantitative measurement of laterally heterogeneous samples

    NASA Astrophysics Data System (ADS)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2012-02-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to materials on metallic surfaces for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases -- uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. The degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  17. Parallel and serial computing tools for testing single-locus and epistatic SNP effects of quantitative traits in genome-wide association studies

    PubMed Central

    Ma, Li; Runesha, H Birali; Dvorkin, Daniel; Garbe, John R; Da, Yang

    2008-01-01

    Background Genome-wide association studies (GWAS) using single nucleotide polymorphism (SNP) markers provide opportunities to detect epistatic SNPs associated with quantitative traits and to detect the exact mode of an epistasis effect. Computational difficulty is the main bottleneck for epistasis testing in large scale GWAS. Results The EPISNPmpi and EPISNP computer programs were developed for testing single-locus and epistatic SNP effects on quantitative traits in GWAS, including tests of three single-locus effects for each SNP (SNP genotypic effect, additive and dominance effects) and five epistasis effects for each pair of SNPs (two-locus interaction, additive × additive, additive × dominance, dominance × additive, and dominance × dominance) based on the extended Kempthorne model. EPISNPmpi is the parallel computing program for epistasis testing in large scale GWAS and achieved excellent scalability for large scale analysis and portability for various parallel computing platforms. EPISNP is the serial computing program based on the EPISNPmpi code for epistasis testing in small scale GWAS using commonly available operating systems and computer hardware. Three serial computing utility programs were developed for graphical viewing of test results and epistasis networks, and for estimating CPU time and disk space requirements. Conclusion The EPISNPmpi parallel computing program provides an effective computing tool for epistasis testing in large scale GWAS, and the epiSNP serial computing programs are convenient tools for epistasis analysis in small scale GWAS using commonly available computer hardware. PMID:18644146

  18. Quantitative Proteomics Analysis of Herbaceous Peony in Response to Paclobutrazol Inhibition of Lateral Branching

    PubMed Central

    Zhao, Daqiu; Gong, Saijie; Hao, Zhaojun; Meng, Jiasong; Tao, Jun

    2015-01-01

    Herbaceous peony (Paeonia lactiflora Pall.) is an emerging high-grade cut flower worldwide, which is usually used in wedding bouquets and known as the “wedding flower”. However, abundant lateral branches appear frequently in some excellent cultivars, and a lack of a method to remove Paeonia lactiflora lateral branches other than inefficient artificial methods is an obstacle for improving the quality of its cut flowers. In this study, paclobutrazol (PBZ) application was found to inhibit the growth of lateral branches in Paeonia lactiflora for the first time, including 96.82% decreased lateral bud number per branch, 77.79% and 42.31% decreased length and diameter of lateral branches, respectively, declined cell wall materials and changed microstructures. Subsequently, isobaric tag for relative and absolute quantitation (iTRAQ) technology was used for quantitative proteomics analysis of lateral branches under PBZ application and control. The results indicated that 178 differentially expressed proteins (DEPs) successfully obtained, 98 DEPs were up-regulated and 80 DEPs were down-regulated. Thereafter, 34 candidate DEPs associated with the inhibited growth of lateral branches were screened according to their function and classification. These PBZ-stress responsive candidate DEPs were involved in eight biological processes, which played a very important role in the growth and development of lateral branches together with the response to PBZ stress. These results provide a better understanding of the molecular theoretical basis for removing Paeonia lactiflora lateral branches using PBZ application. PMID:26473855

  19. Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability

    PubMed Central

    Tang, M.-X.; Mulvana, H.; Gauthier, T.; Lim, A. K. P.; Cosgrove, D. O.; Eckersley, R. J.; Stride, E.

    2011-01-01

    Ultrasound provides a valuable tool for medical diagnosis offering real-time imaging with excellent spatial resolution and low cost. The advent of microbubble contrast agents has provided the additional ability to obtain essential quantitative information relating to tissue vascularity, tissue perfusion and even endothelial wall function. This technique has shown great promise for diagnosis and monitoring in a wide range of clinical conditions such as cardiovascular diseases and cancer, with considerable potential benefits in terms of patient care. A key challenge of this technique, however, is the existence of significant variations in the imaging results, and the lack of understanding regarding their origin. The aim of this paper is to review the potential sources of variability in the quantification of tissue perfusion based on microbubble contrast-enhanced ultrasound images. These are divided into the following three categories: (i) factors relating to the scanner setting, which include transmission power, transmission focal depth, dynamic range, signal gain and transmission frequency, (ii) factors relating to the patient, which include body physical differences, physiological interaction of body with bubbles, propagation and attenuation through tissue, and tissue motion, and (iii) factors relating to the microbubbles, which include the type of bubbles and their stability, preparation and injection and dosage. It has been shown that the factors in all the three categories can significantly affect the imaging results and contribute to the variations observed. How these factors influence quantitative imaging is explained and possible methods for reducing such variations are discussed. PMID:22866229

  20. Quantitative PET studies of the serotonin transporter in MDMA users and controls using [11C]McN5652 and [11C]DASB.

    PubMed

    McCann, Una D; Szabo, Zsolt; Seckin, Esen; Rosenblatt, Peter; Mathews, William B; Ravert, Hayden T; Dannals, Robert F; Ricaurte, George A

    2005-09-01

    (+/-)3,4-Methylenedioxymethamphetamine (MDMA, 'Ecstasy') is a widely used illicit drug that produces toxic effects on brain serotonin axons and axon terminals in animals. The results of clinical studies addressing MDMA's serotonin neurotoxic potential in humans have been inconclusive. In the present study, 23 abstinent MDMA users and 19 non-MDMA controls underwent quantitative positron emission tomography (PET) studies using [11C]McN5652 and [11C]DASB, first- and second-generation serotonin transporter (SERT) ligands previously validated in baboons for detecting MDMA-induced brain serotonin neurotoxicity. Global and regional distribution volumes (DVs) and two additional SERT-binding parameters (DV(spec) and DVR) were compared in the two subject populations using parametric statistical analyses. Data from PET studies revealed excellent correlations between the various binding parameters of [11C]McN5652 and [11C]DASB, both in individual brain regions and individual subjects. Global SERT reductions were found in MDMA users with both PET ligands, using all three of the above-mentioned SERT-binding parameters. Preplanned comparisons in 15 regions of interest demonstrated reductions in selected cortical and subcortical structures. Exploratory correlational analyses suggested that SERT measures recover with time, and that loss of the SERT is directly associated with MDMA use intensity. These quantitative PET data, obtained using validated first- and second-generation SERT PET ligands, provide strong evidence of reduced SERT density in some recreational MDMA users.

  1. In-vitro analysis of early calcification in aortic valvular interstitial cells using Laser-Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Davari, Seyyed Ali; Masjedi, Shirin; Ferdous, Zannatul; Mukherjee, Dibyendu

    2018-01-01

    Calcific aortic valve disease (CAVD) is a major cardiovascular disorder caused by osteogenic differentiation of valvular interstitial cells (VICs) within aortic valves. Conventional methods like colorimetric assays and histology fail to detect small calcium depositions during in-vitro VIC cultures. Laser-induced breakdown spectroscopy (LIBS) is a robust analytical tool used for inorganic materials characterizations, but relatively new to biomedical applications. We employ LIBS, for the first time, for quantitative in-vitro detection of calcium depositions in VICs at various osteogenic differentiation stages. VICs isolated from porcine aortic valves were cultured in osteogenic media over various days. Colorimetric calcium assays based on arsenazo dye and Von Kossa staining measured the calcium depositions within VICs. Simultaneously, LIBS signatures for Ca I (422.67 nm) atomic emission lines were collected for estimating calcium depositions in lyophilized VIC samples. Our results indicate excellent linear correlation between the calcium assay and our LIBS measurements. Furthermore, unlike the assay results, the LIBS results could resolve calcium signals from cell samples with as early as 2 days of osteogenic culture. Quantitatively, the LIBS measurements establish the limit of detection for calcium content in VICs to be ∼0.17±0.04 μg which indicates a 5-fold improvement over calcium assay. Picture: Quantitative LIBS enables in-vitro analysis for early stage detection of calcium deposition within aortic valvular interstitial cells (VICs). © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. A Quantitative Proteomics Approach to Clinical Research with Non-Traditional Samples

    PubMed Central

    Licier, Rígel; Miranda, Eric; Serrano, Horacio

    2016-01-01

    The proper handling of samples to be analyzed by mass spectrometry (MS) can guarantee excellent results and a greater depth of analysis when working in quantitative proteomics. This is critical when trying to assess non-traditional sources such as ear wax, saliva, vitreous humor, aqueous humor, tears, nipple aspirate fluid, breast milk/colostrum, cervical-vaginal fluid, nasal secretions, bronco-alveolar lavage fluid, and stools. We intend to provide the investigator with relevant aspects of quantitative proteomics and to recognize the most recent clinical research work conducted with atypical samples and analyzed by quantitative proteomics. Having as reference the most recent and different approaches used with non-traditional sources allows us to compare new strategies in the development of novel experimental models. On the other hand, these references help us to contribute significantly to the understanding of the proportions of proteins in different proteomes of clinical interest and may lead to potential advances in the emerging field of precision medicine. PMID:28248241

  3. A Quantitative Proteomics Approach to Clinical Research with Non-Traditional Samples.

    PubMed

    Licier, Rígel; Miranda, Eric; Serrano, Horacio

    2016-10-17

    The proper handling of samples to be analyzed by mass spectrometry (MS) can guarantee excellent results and a greater depth of analysis when working in quantitative proteomics. This is critical when trying to assess non-traditional sources such as ear wax, saliva, vitreous humor, aqueous humor, tears, nipple aspirate fluid, breast milk/colostrum, cervical-vaginal fluid, nasal secretions, bronco-alveolar lavage fluid, and stools. We intend to provide the investigator with relevant aspects of quantitative proteomics and to recognize the most recent clinical research work conducted with atypical samples and analyzed by quantitative proteomics. Having as reference the most recent and different approaches used with non-traditional sources allows us to compare new strategies in the development of novel experimental models. On the other hand, these references help us to contribute significantly to the understanding of the proportions of proteins in different proteomes of clinical interest and may lead to potential advances in the emerging field of precision medicine.

  4. Quantitative x-ray phase-contrast imaging using a single grating of comparable pitch to sample feature size.

    PubMed

    Morgan, Kaye S; Paganin, David M; Siu, Karen K W

    2011-01-01

    The ability to quantitatively retrieve transverse phase maps during imaging by using coherent x rays often requires a precise grating or analyzer-crystal-based setup. Imaging of live animals presents further challenges when these methods require multiple exposures for image reconstruction. We present a simple method of single-exposure, single-grating quantitative phase contrast for a regime in which the grating period is much greater than the effective pixel size. A grating is used to create a high-visibility reference pattern incident on the sample, which is distorted according to the complex refractive index and thickness of the sample. The resolution, along a line parallel to the grating, is not restricted by the grating spacing, and the detector resolution becomes the primary determinant of the spatial resolution. We present a method of analysis that maps the displacement of interrogation windows in order to retrieve a quantitative phase map. Application of this analysis to the imaging of known phantoms shows excellent correspondence.

  5. The relationship between quantitative measures of disc height and disc signal intensity with Pfirrmann score of disc degeneration.

    PubMed

    Salamat, Sara; Hutchings, John; Kwong, Clemens; Magnussen, John; Hancock, Mark J

    2016-01-01

    To assess the relationship between quantitative measures of disc height and signal intensity with the Pfirrmann disc degeneration scoring system and to test the inter-rater reliability of the quantitative measures. Participants were 76 people who had recently recovered from their last episode of acute low back pain and underwent MRI scan on a single 3T machine. At all 380 lumbar discs, quantitative measures of disc height and signal intensity were made by 2 independent raters and compared to Pfirrmann scores from a single radiologist. For quantitative measures of disc height and signal intensity a "raw" score and 2 adjusted ratios were calculated and the relationship with Pfirrmann scores was assessed. The inter-tester reliability of quantitative measures was also investigated. There was a strong linear relationship between quantitative disc signal intensity and Pfirrmann scores for grades 1-4, but not for grades 4 and 5. For disc height only, Pfirrmann grade 5 had significantly reduced disc height compared to all other grades. Results were similar regardless of whether raw or adjusted scores were used. Inter-rater reliability for the quantitative measures was excellent (ICC > 0.97). Quantitative measures of disc signal intensity were strongly related to Pfirrmann scores from grade 1 to 4; however disc height only differentiated between grade 4 and 5 Pfirrmann scores. Using adjusted ratios for quantitative measures of disc height or signal intensity did not significantly alter the relationship with Pfirrmann scores.

  6. Part-Time Occupational Faculty: A Contribution to Excellence. Information Series No. 300.

    ERIC Educational Resources Information Center

    Parsons, Michael H.

    Part-time faculty are essential to the accomplishment of the mission of postsecondary occupational education institutions. A commitment to excellence requires a comprehensive, systematic design for part-time faculty recruitment, development, assessment, and integration into the institution's delivery system. Careful attention to recruitment…

  7. The silver effect of admission glucose level on excellent outcome in thrombolysed stroke patients.

    PubMed

    Rosso, Charlotte; Baronnet, Flore; Diaz, Belen; Le Bouc, Raphael; Frasca Polara, Giulia; Moulton, Eric Jr; Deltour, Sandrine; Leger, Anne; Crozier, Sophie; Samson, Yves

    2018-05-18

    Higher admission glucose levels (AGL) are associated with less favorable outcome in thrombolysis. But, could AGL's impact on outcome vary by onset-to-treatment (OTT) time? Is hyperglycemia associated with a shorter therapeutic time window for excellent outcome for thrombolysed stroke patients? We assessed predictive values of AGL, baseline NIHSS, age, and OTT time quartiles on excellent outcome (3-month modified Rankin score of 0-1) in 773 patients treated by rt-Pa. We added the AGL × OTT time quartile interaction in the model and separately analyzed the predictive values of AGL, age, and NIHSS for each OTT time quartile if the interaction was significant. AGL, baseline NIHSS, age, and OTT time quartiles were significant predictors. When added in the model, the AGL × OTT interaction was significant (OR: 0.96, 95% CI: 0.94-0.99, p: 0.0009). AGL was predictive only during the third OTT time quartile (181-224 min). During this period, the predicted rate of excellent outcome was 16% for AGL = 6.5 mmol/L and 8% for AGL = 8 mmol/L. The rate of excellent outcome was not decreased in hyperglycemic patients for OTT time ≤ 180 min (20 vs. 24.5% p: 0.37), but was decreased for OTT time > 180 min (9.6 vs. 26.7% p: 0.00001). Similar results were found in patients with MCA recanalization, but not in patients without recanalization. The therapeutic time window for excellent outcome is shortened in hyperglycemic patients. This would support the design of "freezing penumbra" randomized trials based on ultra-early AGL control.

  8. Vocal fold motion outcome based on excellent prognosis with laryngeal electromyography.

    PubMed

    Smith, Libby J; Rosen, Clark A; Munin, Michael C

    2016-10-01

    As laryngeal electromyography (LEMG) becomes more refined, accurate predictions of vocal fold motion recovery are possible. Focus has been on outcomes for patients with poor prognosis for vocal fold motion recovery. Limited information is available regarding the expected rate of purposeful vocal fold motion recovery when there is good to normal motor recruitment, no signs of denervation, and no signs of synkinetic activity with LEMG, termed excellent prognosis. The objective of this study is to determine the rate of vocal fold motion recovery with excellent prognosis findings on LEMG after acute recurrent laryngeal nerve injury. Retrospective review. Patients undergoing a standardized LEMG protocol, consisting of qualitative (evaluation of motor recruitment, motor unit configuration, detection of fibrillations, presence of synkinesis) and quantitative (turns analysis) measurements were evaluated for purposeful vocal-fold motion recovery, calculated after at least 6 months since onset of injury. Twenty-three patients who underwent LEMG for acute vocal fold paralysis met the inclusion criteria of excellent prognosis. Eighteen patients (78.3%) recovered vocal fold motion, as determined by flexible laryngoscopy. Nearly 80% of patients determined to have excellent prognosis for vocal fold motion recovery experienced return of vocal fold motion. This information will help clinicians not only counsel their patients on expectations but will also help guide treatment. 4. Laryngoscope, 126:2310-2314, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  9. A connectionist modeling study of the neural mechanisms underlying pain's ability to reorient attention.

    PubMed

    Dowman, Robert; Ritz, Benjamin; Fowler, Kathleen

    2016-08-01

    Connectionist modeling was used to investigate the brain mechanisms responsible for pain's ability to shift attention away from another stimulus modality and toward itself. Different connectionist model architectures were used to simulate the different possible brain mechanisms underlying this attentional bias, where nodes in the model simulated the brain areas thought to mediate the attentional bias, and the connections between the nodes simulated the interactions between the brain areas. Mathematical optimization techniques were used to find the model parameters, such as connection strengths, that produced the best quantitative fits of reaction time and event-related potential data obtained in our previous work. Of the several architectures tested, two produced excellent quantitative fits of the experimental data. One involved an unexpected pain stimulus activating somatic threat detectors in the dorsal posterior insula. This threat detector activity was monitored by the medial prefrontal cortex, which in turn evoked a phasic response in the locus coeruleus. The locus coeruleus phasic response resulted in a facilitation of the cortical areas involved in decision and response processes time-locked to the painful stimulus. The second architecture involved the presence of pain causing an increase in general arousal. The increase in arousal was mediated by locus coeruleus tonic activity, which facilitated responses in the cortical areas mediating the sensory, decision, and response processes involved in the task. These two neural network architectures generated competing predictions that can be tested in future studies.

  10. Rapid acquisition of magnetic resonance imaging of the shoulder using three-dimensional fast spin echo sequence with compressed sensing.

    PubMed

    Lee, Seung Hyun; Lee, Young Han; Song, Ho-Taek; Suh, Jin-Suck

    2017-10-01

    To evaluate the feasibility of 3D fast spin-echo (FSE) imaging with compressed sensing (CS) for the assessment of shoulder. Twenty-nine patients who underwent shoulder MRI including image sets of axial 3D-FSE sequence without CS and with CS, using an acceleration factor of 1.5, were included. Quantitative assessment was performed by calculating the root mean square error (RMSE) and structural similarity index (SSIM). Two musculoskeletal radiologists compared image quality of 3D-FSE sequences without CS and with CS, and scored the qualitative agreement between sequences, using a five-point scale. Diagnostic agreement for pathologic shoulder lesions between the two sequences was evaluated. The acquisition time of 3D-FSE MRI was reduced using CS (3min 23s vs. 2min 22s). Quantitative evaluations showed a significant correlation between the two sequences (r=0.872-0.993, p<0.05) and SSIM was in an acceptable range (0.940-0.993; mean±standard deviation, 0.968±0.018). Qualitative image quality showed good to excellent agreement between 3D-FSE images without CS and with CS. Diagnostic agreement for pathologic shoulder lesions between the two sequences was very good (κ=0.915-1). The 3D-FSE sequence with CS is feasible in evaluating the shoulder joint with reduced scan time compared to 3D-FSE without CS. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. A flexible and stable surface-enhanced Raman scattering (SERS) substrate based on Au nanoparticles/Graphene oxide/Cicada wing array

    NASA Astrophysics Data System (ADS)

    Shi, Guochao; Wang, Mingli; Zhu, Yanying; Shen, Lin; Wang, Yuhong; Ma, Wanli; Chen, Yuee; Li, Ruifeng

    2018-04-01

    In this work, we presented an eco-friendly and low-cost method to fabricate a kind of flexible and stable Au nanoparticles/graphene oxide/cicada wing (AuNPs/GO/CW) substrate. By controlling the ratio of reactants, the optimum SERS substrate with average AuNPs size of 65 nm was obtained. The Raman enhancement factor for rhodamine 6G (R6G) was 1.08 ×106 and the limit of detection (LOD) was as low as 10-8 M. After calibrating the Raman peak intensities of R6G, it could be quantitatively detected. In order to better understand the experimental results, the 3D finite-different time-domain simulation was used to simulate the AuNPs/GO/CW-1 (the diameter of the AuNPs was 65 nm) to further investigate the SERS enhancement effect. More importantly, the AuNPs/GO/CW-1 substrates not only can provide strong enhancement factors but also can be stable and reproducible. This SERS substrates owned a good stability for the SERS intensity which was reduced only by 25% after the aging time of 60 days and the relative standard deviation was lower than 20%, revealing excellent uniformity and reproducibility. Our positive findings can pave a new way to optimize the application of SERS substrate as well as provide more SERS platforms for quantitative detection of organic contaminants vestige, which makes it very promising in the trace detection of biological molecules.

  12. Stroke onset time estimation from multispectral quantitative magnetic resonance imaging in a rat model of focal permanent cerebral ischemia.

    PubMed

    McGarry, Bryony L; Rogers, Harriet J; Knight, Michael J; Jokivarsi, Kimmo T; Sierra, Alejandra; Gröhn, Olli Hj; Kauppinen, Risto A

    2016-08-01

    Quantitative T2 relaxation magnetic resonance imaging allows estimation of stroke onset time. We aimed to examine the accuracy of quantitative T1 and quantitative T2 relaxation times alone and in combination to provide estimates of stroke onset time in a rat model of permanent focal cerebral ischemia and map the spatial distribution of elevated quantitative T1 and quantitative T2 to assess tissue status. Permanent middle cerebral artery occlusion was induced in Wistar rats. Animals were scanned at 9.4T for quantitative T1, quantitative T2, and Trace of Diffusion Tensor (Dav) up to 4 h post-middle cerebral artery occlusion. Time courses of differentials of quantitative T1 and quantitative T2 in ischemic and non-ischemic contralateral brain tissue (ΔT1, ΔT2) and volumes of tissue with elevated T1 and T2 relaxation times (f1, f2) were determined. TTC staining was used to highlight permanent ischemic damage. ΔT1, ΔT2, f1, f2, and the volume of tissue with both elevated quantitative T1 and quantitative T2 (V(Overlap)) increased with time post-middle cerebral artery occlusion allowing stroke onset time to be estimated. V(Overlap) provided the most accurate estimate with an uncertainty of ±25 min. At all times-points regions with elevated relaxation times were smaller than areas with Dav defined ischemia. Stroke onset time can be determined by quantitative T1 and quantitative T2 relaxation times and tissue volumes. Combining quantitative T1 and quantitative T2 provides the most accurate estimate and potentially identifies irreversibly damaged brain tissue. © 2016 World Stroke Organization.

  13. Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays.

    PubMed

    Hopkins, Mark; Hau, Sarah; Tiernan, Caroline; Papadimitropoulos, Athanasios; Chawla, Anu; Beloukas, Apostolos; Geretti, Anna Maria

    2015-08-01

    Quantitative measurement of HIV-1 RNA levels in plasma ('viral load') plays a central role in clinical management. The choice of assay platform can influence results and treatment decisions. To compare the analytical performance of the new TMA-based Hologic Aptima(®) HIV-1 Quant Dx assay with that of three PCR-based assays: Abbott RealTime HIV-1, Qiagen Artus(®) HI Virus-1 QS-RGQ, and Roche CAP/CTM HIV-1 Test v2. Assay performance was evaluated using Acrometrix HIV-1 RNA Standard panels; the 3rd WHO HIV-1 RNA International Standard (12-500 copies/ml; 6 dilutions; 9 replicates); and plasma samples from 191 HIV-positive patients. Aptima showed high (>0.99) precision, accuracy and concordance with the Acrometrix Standards across a wide dynamic range (2.0-6.7 log10copies/ml). Variance caused up to 2.1 (Aptima), 1.7 (RealTime), 7.5 (Artus), and 1.9 (CAP/CTM) fold changes in the International Standard quantifications at 50-500 copies/ml. HIV-1 RNA detection rates in plasma samples were 141/191 (74%), 119/191 (62%), 108/191 (57%), and 145/191 (76%) for Aptima, RealTime, Artus and CAP/CTM, respectively. For categorising samples either side of 50 copies/ml, Aptima had excellent agreement with RealTime (kappa 0.92; 95% CI 0.87-0.98); lowest agreement was with Artus (kappa 0.79; 95%CI 0.70-0.88). Aptima quantifications were mean 0.12 and 0.06 log10copies/ml higher compared with RealTime and CAP/CTM, respectively, and 0.05 log10copies/ml lower compared with Artus. Limits of agreement were narrowest when comparing Aptima to RealTime. The new Aptima HIV assay is sensitive, precise, and accurate. HIV assays exhibit discordance at low HIV-1 RNA copy numbers. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects.

    PubMed

    Fang, Danqi; Tang, Fang Yao; Huang, Haifan; Cheung, Carol Y; Chen, Haoyu

    2018-05-29

    To investigate the repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography (SS-OCTA) metrics in healthy subjects. Thirty-three healthy normal subjects were enrolled. The macula was scanned four times by an SS-OCTA system using the 3 mm×3 mm mode. The superficial capillary map images were analysed using a MATLAB program. A series of parameters were measured: foveal avascular zone (FAZ) area, FAZ perimeter, FAZ circularity, parafoveal vessel density, fractal dimension and vessel diameter index (VDI). The repeatability of four scans was determined by intraclass correlation coefficient (ICC). Then the averaged results were analysed for intereye difference, correlation and agreement using paired t-test, Pearson's correlation coefficient (r), ICC and Bland-Altman plot. The repeatability assessment of the macular metrics exported high ICC values (ranged from 0.853 to 0.996). There is no statistically significant difference in the OCTA metrics between the two eyes. FAZ area (ICC=0.961, r=0.929) and FAZ perimeter (ICC=0.884, r=0.802) showed excellent binocular correlation. Fractal dimension (ICC=0.732, r=0.578) and VDI (ICC=0.707, r=0.547) showed moderate binocular correlation, while parafoveal vessel density had poor binocular correlation. Bland-Altman plots showed the range of agreement was from -0.0763 to 0.0954 mm 2 for FAZ area and from -0.0491 to 0.1136 for parafoveal vessel density. The macular metrics obtained using SS-OCTA showed excellent repeatability in healthy subjects. We showed high intereye correlation in FAZ area and perimeter, moderate correlation in fractal dimension and VDI, while vessel density had poor correlation in normal healthy subjects. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Does overall reinforcer rate affect discrimination of time-based contingencies?

    PubMed

    Cowie, Sarah; Davison, Michael; Blumhardt, Luca; Elliffe, Douglas

    2016-05-01

    Overall reinforcer rate appears to affect choice. The mechanism for such an effect is uncertain, but may relate to reinforcer rate changing the discrimination of the relation between stimuli and reinforcers. We assessed whether a quantitative model based on a stimulus-control approach could be used to account for the effects of overall reinforcer rate on choice under changing time-based contingencies. On a two-key concurrent schedule, the likely availability of a reinforcer reversed when a fixed time had elapsed since the last reinforcer, and the overall reinforcer rate was varied across conditions. Changes in the overall reinforcer rate produced a change in response bias, and some indication of a change in discrimination. These changes in bias and discrimination always occurred quickly, usually within the first session of a condition. The stimulus-control approach provided an excellent account of the data, suggesting that changes in overall reinforcer rate affect choice because they alter the frequency of reinforcers obtained at different times, or in different stimulus contexts, and thus change the discriminated relation between stimuli and reinforcers. These findings support the notion that temporal and spatial discriminations can be understood in terms of discrimination of reinforcers across time and space. © 2016 Society for the Experimental Analysis of Behavior.

  16. Quantitative determination of Auramine O by terahertz spectroscopy with 2DCOS-PLSR model

    NASA Astrophysics Data System (ADS)

    Zhang, Huo; Li, Zhi; Chen, Tao; Qin, Binyi

    2017-09-01

    Residues of harmful dyes such as Auramine O (AO) in herb and food products threaten the health of people. So, fast and sensitive detection techniques of the residues are needed. As a powerful tool for substance detection, terahertz (THz) spectroscopy was used for the quantitative determination of AO by combining with an improved partial least-squares regression (PLSR) model in this paper. Absorbance of herbal samples with different concentrations was obtained by THz-TDS in the band between 0.2THz and 1.6THz. We applied two-dimensional correlation spectroscopy (2DCOS) to improve the PLSR model. This method highlighted the spectral differences of different concentrations, provided a clear criterion of the input interval selection, and improved the accuracy of detection result. The experimental result indicated that the combination of the THz spectroscopy and 2DCOS-PLSR is an excellent quantitative analysis method.

  17. Digging Deeper: Professional Learning Can Go beyond the Basics to Reach Underserved Students

    ERIC Educational Resources Information Center

    Gleason, Sonia Caus

    2010-01-01

    Consistent, excellent teaching is the single greatest factor in improving student achievement over time. School leadership is the second. Excellent teaching and strong leadership require deliberate, ongoing professional learning. In working with high-poverty school systems over time, the following basics emerge: (1) time; (2) content; (3)…

  18. Quantitative analysis of seizure frequency 1 week and 6, 12, and 24 months after surgery of epilepsy.

    PubMed

    Lüders, H; Murphy, D; Awad, I; Wyllie, E; Dinner, D S; Morris, H H; Rothner, A D

    1994-01-01

    We made quantitative analysis of seizure frequency 1 week and 6, 12, and 24 months after seizure surgery. Seizure recurrence was significantly higher when seizures occurred in the first postoperative week. Seizure recurrence increased progressively with longer follow-ups, but the 6 month postoperative follow-up period was an excellent index of long-term outcome. In operative follow-up studies, seizure frequency should be reported at fixed follow-up periods, e.g., at 6 months and 1, 2, 5, and 10 years. Meaningful comparison of outcomes between different studies is possible only when reports include outcome at fixed postoperative follow-up periods (as opposed to ranges of follow-up periods).

  19. Quantifying the Beauty of Words: A Neurocognitive Poetics Perspective

    PubMed Central

    Jacobs, Arthur M.

    2017-01-01

    In this paper I would like to pave the ground for future studies in Computational Stylistics and (Neuro-)Cognitive Poetics by describing procedures for predicting the subjective beauty of words. A set of eight tentative word features is computed via Quantitative Narrative Analysis (QNA) and a novel metric for quantifying word beauty, the aesthetic potential is proposed. Application of machine learning algorithms fed with this QNA data shows that a classifier of the decision tree family excellently learns to split words into beautiful vs. ugly ones. The results shed light on surface and semantic features theoretically relevant for affective-aesthetic processes in literary reading and generate quantitative predictions for neuroaesthetic studies of verbal materials. PMID:29311877

  20. Quantifying the Beauty of Words: A Neurocognitive Poetics Perspective.

    PubMed

    Jacobs, Arthur M

    2017-01-01

    In this paper I would like to pave the ground for future studies in Computational Stylistics and (Neuro-)Cognitive Poetics by describing procedures for predicting the subjective beauty of words. A set of eight tentative word features is computed via Quantitative Narrative Analysis (QNA) and a novel metric for quantifying word beauty, the aesthetic potential is proposed. Application of machine learning algorithms fed with this QNA data shows that a classifier of the decision tree family excellently learns to split words into beautiful vs. ugly ones. The results shed light on surface and semantic features theoretically relevant for affective-aesthetic processes in literary reading and generate quantitative predictions for neuroaesthetic studies of verbal materials.

  1. An ultra-high-density map as a community resource for discerning the genetic basis of quantitative traits in maize

    USDA-ARS?s Scientific Manuscript database

    In this study, we generated a linkage map containing 1,151,856 high quality SNPs between Mo17 and B73, which were verified in the maize intermated B73'×'Mo17 (IBM) Syn10 population. This resource is an excellent complement to existing maize genetic maps available in an online database (iPlant, http:...

  2. Application of several physical techniques in the total analysis of a canine urinary calculus.

    PubMed

    Rodgers, A L; Mezzabotta, M; Mulder, K J; Nassimbeni, L R

    1981-06-01

    A single calculus from the bladder of a Beagle bitch has been analyzed by a multiple technique approach employing x-ray diffraction, infrared spectroscopy, scanning electron microscopy, x-ray fluorescence spectrometry, atomic absorption spectrophotometry and density gradient fractionation. The qualitative and quantitative data obtained showed excellent agreement, lending confidence to such an approach for the evaluation and understanding of stone disease.

  3. Balancing Considerations of Equity, Content Quality, and Technical Excellence in Designing, Validating and Implementing Performance Assessments in the Context of Mathematics Instructional Reform: The Experience of the QUASAR Project.

    ERIC Educational Resources Information Center

    Silver, Edward A.; Lane, Suzanne

    Issues of educational equity and quality are explored in the context of the Quantitative Understanding: Amplifying Student Achievement and Reasoning (QUASAR) project, a national educational reform project aimed at fostering and studying the development and implementation of enhanced mathematics instructional programs for students attending middle…

  4. [Fragments of history in psychiatric care Rio Grande do Norte, Brazil].

    PubMed

    de Miranda, Francisco Arnoldo Nunes; Santos, Raionara Cristina de Araújo; de Azevedo, Dulcian Medeiros; Fernandes, Rafaella Leite; Costa, Tarciana Sampaio

    2010-09-01

    This article aims to rescue aspects of the performing therapeutic of the Day Hospital (HD) Dr Elger Nunes, Natal, Rio Grande do Norte, Brazil, during its term, and analyze the results regarding to the number of patients assisted from 1996 to 2004. This is an empirical, descriptive and exploratory study, ex post facto with a quantitative approach, carried out through the analysis of the records of 910 people attended in the hospital. The data was submitted to the informational resource software Microsoft Excel and converted into diagrams. The results show a greater accessibility to this treatment modality, decreasing in hospitalization-time length and improving hospital discharge conditions for users, with reduction in number of patients who interrupted treatment. It focus on the importance of the Day Hospital in the process of psychiatric reform, with care grounded on the use of the humanized therapeutic practices, and still not losing the bond with family and society.

  5. Tabletop imaging of structural evolutions in chemical reactions demonstrated for the acetylene cation

    NASA Astrophysics Data System (ADS)

    Ibrahim, Heide; Wales, Benji; Beaulieu, Samuel; Schmidt, Bruno E.; Thiré, Nicolas; Fowe, Emmanuel P.; Bisson, Éric; Hebeisen, Christoph T.; Wanie, Vincent; Giguére, Mathieu; Kieffer, Jean-Claude; Spanner, Michael; Bandrauk, André D.; Sanderson, Joseph; Schuurman, Michael S.; Légaré, François

    2014-07-01

    The introduction of femto-chemistry has made it a primary goal to follow the nuclear and electronic evolution of a molecule in time and space as it undergoes a chemical reaction. Using Coulomb Explosion Imaging, we have shot the first high-resolution molecular movie of a to and fro isomerization process in the acetylene cation. So far, this kind of phenomenon could only be observed using vacuum ultraviolet light from a free-electron laser. Here we show that 266 nm ultrashort laser pulses are capable of initiating rich dynamics through multiphoton ionization. With our generally applicable tabletop approach that can be used for other small organic molecules, we have investigated two basic chemical reactions simultaneously: proton migration and C=C bond breaking, triggered by multiphoton ionization. The experimental results are in excellent agreement with the timescales and relaxation pathways predicted by new and quantitative ab initio trajectory simulations.

  6. Analysis of spectra using correlation functions

    NASA Technical Reports Server (NTRS)

    Beer, Reinhard; Norton, Robert H.

    1988-01-01

    A novel method is presented for the quantitative analysis of spectra based on the properties of the cross correlation between a real spectrum and either a numerical synthesis or laboratory simulation. A new goodness-of-fit criterion called the heteromorphic coefficient H is proposed that has the property of being zero when a fit is achieved and varying smoothly through zero as the iteration proceeds, providing a powerful tool for automatic or near-automatic analysis. It is also shown that H can be rendered substantially noise-immune, permitting the analysis of very weak spectra well below the apparent noise level and, as a byproduct, providing Doppler shift and radial velocity information with excellent precision. The technique is in regular use in the Atmospheric Trace Molecule Spectroscopy (ATMOS) project and operates in an interactive, realtime computing environment with turn-around times of a few seconds or less.

  7. Evaluation of direct saponification method for determination of cholesterol in meats.

    PubMed

    Adams, M L; Sullivan, D M; Smith, R L; Richter, E F

    1986-01-01

    A gas chromatographic (GC) method has been developed for determination of cholesterol in meats. The method involves ethanolic KOH saponification of the sample material, homogeneous-phase toluene extraction of the unsaponifiables, derivatization of cholesterol to its trimethylsilylether, and quantitation by GC-flame ionization detection using 5-alpha-cholestane as internal standard. This direct saponification method is compared with the current AOAC official method for determination of cholesterol in 20 different meat products. The direct saponification method eliminates the need for initial lipid extraction, thus offering a 30% savings in labor, and requires fewer solvents than the AOAC method. It produced comparable or slightly higher cholesterol results than the AOAC method in all meat samples examined. Precision, determined by assaying a turkey meat sample 16 times over 4 days, was excellent (CV = 1.74%). Average recovery of cholesterol added to meat samples was 99.8%.

  8. [Detection of the exogenous gene copy number of the transgenic tomato anti-caries vaccine].

    PubMed

    Bai, Guo-hui; Liu, Jian-guo; Tian, Yuan; Chen, Zhu; Bai, Peng-yuan; Han, Qi; Gu, Yu; Guan, Xiao-yan; Wang, Hai-hui

    2013-12-01

    To detect the exogenous gene copy number of the transgenic tomato anti-caries vaccine by using the SYBR Green real-time PCR. Recombinant plasmid pEAC10 and pEPC10 were used as standard to detect genome samples of exogenous gene pacA-ctxB and pacP-ctxB by SYBR green fluorescent quantitation, then the average value was calculated as gene copy number. The copy number of the transgenic tomato carrying pacA-ctxB was 1.3 and the pacP-ctxB was 3.2. The transgenic tomato plants which have high stability are low-copy transgenic plants. Supported by National Natural Science Foundation of China (30160086, 81260164), Science and Technical Fund of Guizhou Province (LKZ[2011]41), Project of Technology Innovation Team in Guizhou Province, Leading Academic Discipline Construction Project in Guizhou Province and Excellent Scientific Research Team Cultivation Project in Zunyi Medical College ([2012]12).

  9. Continuous-flow oxidative cyanation of primary and secondary amines using singlet oxygen.

    PubMed

    Ushakov, Dmitry B; Gilmore, Kerry; Kopetzki, Daniel; McQuade, D Tyler; Seeberger, Peter H

    2014-01-07

    Primary and secondary amines can be rapidly and quantitatively oxidized to the corresponding imines by singlet oxygen. This reactive form of oxygen was produced using a variable-temperature continuous-flow LED-photoreactor with a catalytic amount of tetraphenylporphyrin as the sensitizer. α-Aminonitriles were obtained in good to excellent yields when trimethylsilyl cyanide served as an in situ imine trap. At 25°C, primary amines were found to undergo oxidative coupling prior to cyanide addition and yielded secondary α-aminonitriles. Primary α-aminonitriles were synthesized from the corresponding primary amines for the first time, by an oxidative Strecker reaction at -50 °C. This atom-economic and protecting-group-free pathway provides a route to racemic amino acids, which was exemplified by the synthesis of tert-leucine hydrochloride from neopentylamine. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Review and Synthesize Completed Research Through Systematic Review.

    PubMed

    Hopp, Lisa; Rittenmeyer, Leslie

    2015-10-01

    The evidence-based health care movement has generated new opportunity for scholars to generate synthesized sources of evidence. Systematic reviews are rigorous forms of synthesized evidence that scholars can conduct if they have requisite skills, time, and access to excellent library resources. Systematic reviews play an important role in synthesizing what is known and unknown about a particular health issue. Thus, they have a synergistic relationship with primary research. They can both inform clinical decisions when the evidence is adequate and identify gaps in knowledge to inform research priorities. Systematic reviews can be conducted of quantitative and qualitative evidence to answer many types of questions. They all share characteristics of rigor that arise from a priori protocol development, transparency, exhaustive searching, dual independent reviewers who critically appraise studies using standardized tools, rigor in synthesis, and peer review at multiple stages in the conduct and reporting of the systematic review. © The Author(s) 2015.

  11. An electrochemical immunosensor for quantitative detection of ficolin-3

    NASA Astrophysics Data System (ADS)

    San, Lili; Zeng, Dongdong; Song, Shiping; Zuo, Xiaolei; Zhang, Huan; Wang, Chenguang; Wu, Jiarui; Mi, Xianqiang

    2016-06-01

    Diabetes mellitus (DM) is one of the most common metabolic disorders in the world, of which more than 90% is type-2 diabetes mellitus (T2DM). There is a rather urgent need for reliable, sensitive and quick detection techniques in clinical application of T2DM. Ficolin-3 is a potential biomarker of T2DM, because serum ficolin-3 levels are associated with insulin resistance and predict the incidence of T2DM. Herein, a sandwich-type electrochemical immunosensor was developed for the detection of ficolin-3 in human serum. Cyclic voltammetry and the amperometric current versus time were used to characterize the performance of the immunosensor. Under optimal conditions, the detection limitation of ficolin-3 was 100 ng ml-1 and the linear dynamic range was between 2 and 50 μg ml-1. The method has ideal accuracy, excellent stability and selectivity and has wide application prospects in clinical research.

  12. Characterization of the evolution of the volume fraction of precipitates in aged AlMgSiCu alloys using DSC technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Esmaeili, Shahrzad; Lloyd, David J.

    2005-11-15

    Differential scanning calorimetry is used to quantify the evolution of the volume fraction of precipitates during age hardening in AlMgSiCu alloys. The calorimetry tests are run on alloy samples after aging for various times at 180 deg. C and the change in the collective heat effects from the major precipitation and dissolution processes in each run are used to determine the precipitation state of the samples. The method is implemented on alloys with various thermal histories prior to artificial aging, including commercial pre-aging histories. The estimated values for the relative volume fraction of precipitates are compared with the results frommore » a newly developed analytical method using isothermal calorimetry and a related quantitative transmission electron microscopy work. Excellent agreement is obtained between the results from various methods.« less

  13. In Situ X-ray Absorption Near-Edge Structure Spectroscopy of ZnO Nanowire Growth During Chemical Bath Deposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McPeak, Kevin M.; Becker, Matthew A.; Britton, Nathan G.

    2010-12-03

    Chemical bath deposition (CBD) offers a simple and inexpensive route to deposit semiconductor nanostructures, but lack of fundamental understanding and control of the underlying chemistry has limited its versatility. Here we report the first use of in situ X-ray absorption spectroscopy during CBD, enabling detailed investigation of both reaction mechanisms and kinetics of ZnO nanowire growth from zinc nitrate and hexamethylenetetramine (HMTA) precursors. Time-resolved X-ray absorption near-edge structure (XANES) spectra were used to quantify Zn(II) speciation in both solution and solid phases. ZnO crystallizes directly from [Zn(H{sub 2}O){sub 6}]{sup 2+} without long-lived intermediates. Using ZnO nanowire deposition as an example,more » this study establishes in situ XANES spectroscopy as an excellent quantitative tool to understand CBD of nanomaterials.« less

  14. Technical Efficiency and Organ Transplant Performance: A Mixed-Method Approach

    PubMed Central

    de-Pablos-Heredero, Carmen; Fernández-Renedo, Carlos; Medina-Merodio, Jose-Amelio

    2015-01-01

    Mixed methods research is interesting to understand complex processes. Organ transplants are complex processes in need of improved final performance in times of budgetary restrictions. As the main objective a mixed method approach is used in this article to quantify the technical efficiency and the excellence achieved in organ transplant systems and to prove the influence of organizational structures and internal processes in the observed technical efficiency. The results show that it is possible to implement mechanisms for the measurement of the different components by making use of quantitative and qualitative methodologies. The analysis show a positive relationship between the levels related to the Baldrige indicators and the observed technical efficiency in the donation and transplant units of the 11 analyzed hospitals. Therefore it is possible to conclude that high levels in the Baldrige indexes are a necessary condition to reach an increased level of the service offered. PMID:25950653

  15. Surface-plasmon mediated total absorption of light into silicon.

    PubMed

    Yoon, Jae Woong; Park, Woo Jae; Lee, Kyu Jin; Song, Seok Ho; Magnusson, Robert

    2011-10-10

    We report surface-plasmon mediated total absorption of light into a silicon substrate. For an Au grating on Si, we experimentally show that a surface-plasmon polariton (SPP) excited on the air/Au interface leads to total absorption with a rate nearly 10 times larger than the ohmic damping rate of collectively oscillating free electrons in the Au film. Rigorous numerical simulations show that the SPP resonantly enhances forward diffraction of light to multiple orders of lossy waves in the Si substrate with reflection and ohmic absorption in the Au film being negligible. The measured reflection and phase spectra reveal a quantitative relation between the peak absorbance and the associated reflection phase change, implying a resonant interference contribution to this effect. An analytic model of a dissipative quasi-bound resonator provides a general formula for the resonant absorbance-phase relation in excellent agreement with the experimental results.

  16. Startup and long term operation of enhanced biological phosphorus removal in continuous-flow reactor with granules.

    PubMed

    Li, Dong; Lv, Yufeng; Zeng, Huiping; Zhang, Jie

    2016-07-01

    The startup and long term operation of enhanced biological phosphorus removal (EBPR) in a continuous-flow reactor (CFR) with granules were investigated in this study. Through reducing the settling time from 9min to 3min gradually, the startup of EBPR in a CFR with granules was successfully realized in 16days. Under continuous-flow operation, the granules with good phosphorus and COD removal performance were stably operated for more than 6months. And the granules were characterized with particle size of around 960μm, loose structure and good settling ability. During the startup phase, polysaccharides (PS) was secreted excessively by microorganisms to resist the influence from the variation of operational mode. Results of relative quantitative PCR indicated that granules dominated by polyphosphate-accumulating organisms (PAOs) were easier accumulated in the CFR because more excellent settling ability was needed in the system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. A spot pattern test chart technique for measurement of geometric aberrations caused by an intervening medium—a novel method

    NASA Astrophysics Data System (ADS)

    Ganesan, A. R.; Arulmozhivarman, P.; Jesson, M.

    2005-12-01

    Accurate surface metrology and transmission characteristics measurements have become vital to certify the manufacturing excellence in the field of glass visors, windshields, menu boards and transportation industries. We report a simple, cost-effective and novel technique for the measurement of geometric aberrations in transparent materials such as glass sheets, Perspex, etc. The technique makes use of an array of spot pattern, we call the spot pattern test chart technique, in the diffraction limited imaging position having large field of view. Performance features include variable angular dynamic range and angular sensitivity. Transparent sheets as the intervening medium introduced in the line of sight, causing aberrations, are estimated in real time using the Zernike reconstruction method. Quantitative comparative analysis between a Shack-Hartmann wavefront sensor and the proposed new method is presented and the results are discussed.

  18. Multidirectional walk test in individuals with Parkinson's disease: a validity study.

    PubMed

    Bryant, Mon S; Workman, Craig D; Jackson, George R

    2015-03-01

    Gait parameters of forward, backward, and sideways walk were studied when the participants walked overground in four directions at their self-selected speed and were compared with walking in the four directions on an instrumented GAITRite walkway. Intraclass correlation coefficients between the overground walk test measures and the instrumented walkway measures of gait speed, cadence, and stride length for the forward walk were 0.85, 0.88, and 0.87, respectively. For the backward walk, the coefficients were 0.91 for gait speed, 0.75 for cadence, and 0.93 for stride length. For the sideways walk, the coefficients were 0.92 for gait speed, 0.93 for cadence, and 0.94 for stride length. Gait parameters of forward, backward, and sideways walk obtained by the overground walk test had excellent agreement with those obtained by the instrumented walkway. The quick timed test provided quantitative data for gait evaluation and was valid for clinical use.

  19. Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Using 82Rb-PET: Comparison with 13N-Ammonia

    PubMed Central

    Fakhri, Georges El

    2011-01-01

    82Rb cardiac PET allows the assessment of myocardial perfusion using a column generator in clinics that lack a cyclotron. We and others have previously shown that quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) is feasible using dynamic 82Rb PET and factor and compartment analyses. The aim of the present work was to determine the intra- and inter-observer variability of MBF estimation using 82Rb PET as well as the reproducibility of our generalized factor + compartment analyses methodology to estimate MBF and assess its accuracy by comparing, in the same subjects, 82Rb estimates of MBF to those obtained using 13N-ammonia. Methods Twenty-two subjects were included in the reproducibility and twenty subjects in the validation study. Patients were injected with 60±5mCi of 82Rb and imaged dynamically for 6 minutes at rest and during dipyridamole stress Left and right ventricular (LV+RV) time-activity curves were estimated by GFADS and used as input to a 2-compartment kinetic analysis that estimates parametric maps of myocardial tissue extraction (K1) and egress (k2), as well as LV+RV contributions (fv,rv). Results Our results show excellent reproducibility of the quantitative dynamic approach itself with coefficients of repeatability of 1.7% for estimation of MBF at rest, 1.4% for MBF at peak stress and 2.8% for CFR estimation. The inter-observer reproducibility between the four observers that participated in this study was also very good with correlation coefficients greater than 0.87 between any two given observers when estimating coronary flow reserve. The reproducibility of MBF in repeated 82Rb studies was good at rest and excellent at peak stress (r2=0.835). Furthermore, the slope of the correlation line was very close to 1 when estimating stress MBF and CFR in repeated 82Rb studies. The correlation between myocardial flow estimates obtained at rest and during peak stress in 82Rb and 13N-ammonia studies was very good at rest (r2=0.843) and stress (r2=0.761). The Bland-Altman plots show no significant presence of proportional error at rest or stress, nor a dependence of the variations on the amplitude of the myocardial blood flow at rest or stress. A small systematic overestimation of 13N-ammonia MBF was observed with 82Rb at rest (0.129 ml/g/min) and the opposite, i.e., underestimation, at stress (0.22 ml/g/min). Conclusions Our results show that absolute quantitation of myocardial bloof flow is reproducible and accurate with 82Rb dynamic cardiac PET as compared to 13N-ammonia. The reproducibility of the quantitation approach itself was very good as well as inter-observer reproducibility. PMID:19525467

  20. Validation of a new UNIX-based quantitative coronary angiographic system for the measurement of coronary artery lesions.

    PubMed

    Bell, M R; Britson, P J; Chu, A; Holmes, D R; Bresnahan, J F; Schwartz, R S

    1997-01-01

    We describe a method of validation of computerized quantitative coronary arteriography and report the results of a new UNIX-based quantitative coronary arteriography software program developed for rapid on-line (digital) and off-line (digital or cinefilm) analysis. The UNIX operating system is widely available in computer systems using very fast processors and has excellent graphics capabilities. The system is potentially compatible with any cardiac digital x-ray system for on-line analysis and has been designed to incorporate an integrated database, have on-line and immediate recall capabilities, and provide digital access to all data. The accuracy (mean signed differences of the observed minus the true dimensions) and precision (pooled standard deviations of the measurements) of the program were determined x-ray vessel phantoms. Intra- and interobserver variabilities were assessed from in vivo studies during routine clinical coronary arteriography. Precision from the x-ray phantom studies (6-In. field of view) for digital images was 0.066 mm and for digitized cine images was 0.060 mm. Accuracy was 0.076 mm (overestimation) for digital images compared to 0.008 mm for digitized cine images. Diagnostic coronary catheters were also used for calibration; accuracy.varied according to size of catheter and whether or not they were filled with iodinated contrast. Intra- and interobserver variabilities were excellent and indicated that coronary lesion measurements were relatively user-independent. Thus, this easy to use and very fast UNIX based program appears to be robust with optimal accuracy and precision for clinical and research applications.

  1. Bioelectrocatalytic application of titania nanotube array for molecule detection.

    PubMed

    Xie, Yibing; Zhou, Limin; Huang, Haitao

    2007-06-15

    A bioelectrocatalysis system based on titania nanotube electrode has been developed for the quantitative detection application. Highly ordered titania nanotube array with inner diameter of 60 nm and total length of 540 nm was formed by anodizing titanium foils. The functionalization modification was achieved by embedding glucose oxidases inside tubule channels and electropolymerizing pyrrole for interfacial immobilization. Morphology and microstructure characterization, electrochemical properties and bioelectrocatalytic reactivities of this composite were fully investigated. The direct detection of hydrogen peroxide by electrocatalytic reduction reaction was fulfilled on pure titania nanotube array with a detection limit up to 2.0 x 10(-4)mM. A biosensor based on the glucose oxidase-titania/titanium electrode was constructed for amperometric detection and quantitative determination of glucose in a phosphate buffer solution (pH 6.8) under a potentiostatic condition (-0.4V versus SCE). The resulting glucose biosensor showed an excellent performance with a response time below 5.6s and a detection limit of 2.0 x 10(-3)mM. The corresponding detection sensitivity was 45.5 microA mM(-1)cm(-2). A good operational reliability was also achieved with relative standard deviations below 3.0%. This novel biosensor exhibited quite high response sensitivity and low detection limit for potential applications.

  2. Characterization of Si (sub X)Ge (sub 1-x)/Si Heterostructures for Device Applications Using Spectroscopic Ellipsometry

    NASA Technical Reports Server (NTRS)

    Sieg, R. M.; Alterovitz, S. A.; Croke, E. T.; Harrell, M. J.; Tanner, M.; Wang, K. L.; Mena, R. A.; Young, P. G.

    1993-01-01

    Spectroscopic ellipsometry (SE) characterization of several complex Si (sub X)Ge (sub 1-x)/Si heterostructures prepared for device fabrication, including structures for heterojunction bipolar transistors (HBT), p-type and n-type heterostructure modulation doped field effect transistors, has been performed. We have shown that SE can simultaneously determine all active layer thicknesses, Si (sub X)Ge (sub 1-x) compositions, and the oxide overlayer thickness, with only a general knowledge of the structure topology needed a priori. The characterization of HBT material included the SE analysis of a Si (sub X)Ge (sub 1-x) layer deeply buried (600 nanometers) under the silicon emitter and cap layers. In the SE analysis of n-type heterostructures, we examined for the first time a silicon layer under tensile strain. We found that an excellent fit can be obtained using optical constants of unstrained silicon to represent the strained silicon conduction layer. We also used SE to measure lateral sample homogeneity, providing quantitative identification of the inhomogeneous layer. Surface overlayers resulting from prior sample processing were also detected and measured quantitatively. These results should allow SE to be used extensively as a non-destructive means of characterizing Si (sub X)Ge (sub 1-x)/Si heterostructures prior to device fabrication and testing.

  3. Effect of sample preparation method on quantification of polymorphs using PXRD.

    PubMed

    Alam, Shahnwaz; Patel, Sarsvatkumar; Bansal, Arvind Kumar

    2010-01-01

    The purpose of this study was to improve the sensitivity and accuracy of quantitative analysis of polymorphic mixtures. Various techniques such as hand grinding and mixing (in mortar and pestle), air jet milling and ball milling for micronization of particle and mixing were used to prepare binary mixtures. Using these techniques, mixtures of form I and form II of clopidogrel bisulphate were prepared in various proportions from 0-5% w/w of form I in form II and subjected to x-ray powder diffraction analysis. In order to obtain good resolution in minimum time, step time and step size were varied to optimize scan rate. Among the six combinations, step size of 0.05 degrees with step time of 5 s demonstrated identification of maximum characteristic peaks of form I in form II. Data obtained from samples prepared using both grinding and mixing in ball mill showed good analytical sensitivity and accuracy compared to other methods. Powder x-ray diffraction method was reproducible, precise with LOD of 0.29% and LOQ of 0.91%. Validation results showed excellent correlation between actual and predicted concentration with R2 > 0.9999.

  4. District Awards for Teacher Excellence (D.A.T.E.) Program: Year One Evaluation Report. Policy Evaluation Report. [Executive Summary

    ERIC Educational Resources Information Center

    Springer, Matthew G.; Lewis, Jessica L.; Podgursky, Michael J.; Ehlert, Mark W.; Taylor, Lori L.; Lopez, Omar S.; Ghoshdastidar, Bonnie; Peng, Art

    2010-01-01

    The District Awards for Teacher Excellence's (D.A.T.E.'s) first year of implementation in 2008-09 occurred at a time when Texas was operating several state-funded performance pay programs. The three-year Governor's Educator Excellence Grant (G.E.E.G.) program was coming to its expected completion, while the Texas Educator Excellence Grant…

  5. Hydrogen bubble dynamic template fabrication of nanoporous Cu film supported by graphene nanaosheets: A highly sensitive sensor for detection of nitrite.

    PubMed

    Majidi, Mir Reza; Ghaderi, Seyran

    2017-12-01

    High surface area nanoporous Cu film (NPCF) has been successfully synthesized using a hydrogen bubble dynamic template on the graphene nanosheets (GNs) modified glassy carbon electrode (GCE). The effect of different synthesis conditions such as applied potential and deposition time on the NPCF morphology was investigated. The structure and constituent of the NPCF-GNs/GCE were characterized by scanning electron microscopy (SEM), energy-dispersive x-ray (EDX), X-ray diffraction (XRD), electrochemical impedance spectroscopy (EIS) and electrochemical methods. The study on electrocatalytic performance of the NPCF-GNs/GCE demonstrated that this electrode has excellent catalytic activity toward nitrite oxidation. The quantitative measurement of nitrite by amperometric method showed a wide concentration range (0.1-100µmolL -1 ) with a detection limit and a sensitivity of 8.87 × 10 -8 molL -1 and 3.1 AL/molcm 2 , respectively. The excellent electrochemical response and high sensitivity of the proposed electrode were attributed to the 3D structure of NPCF and the synergic effect of NPCF and GNs. Furthermore, this electrode showed some other advantages including good repeatability, high reproducibility, long-term stability and anti-interference performance toward nitrite sensing. The applicability of the proposed electrode was proved by successful determination of nitrite in real samples (tap water, river water and sausage samples). Copyright © 2017 Elsevier B.V. All rights reserved.

  6. [The effects of the processing technic on dentinal adhesion].

    PubMed

    Krejci, I; Lutz, F; Perisic, U

    1992-01-01

    In this in vitro study, the effect of application techniques on marginal adaptation of thermal cycled class V restorations restored with an actual dentinal adhesive were quantitated using SEM and dye penetration. Under optimal application conditions, excellent results were generated: though a simple bulk insertion technique was used, no difference was found between enamel and dentin margins before and after thermal loading. On the other hand, contamination of the bonding agent with saliva before composite resin insertion dramatically decreased the percentage of "excellent margin" in dentin and in enamel. Similar effects were found after protecting the bonding agent with an insulating gel. No improvement in marginal adaptation was found after reapplication of the bonding agent. The class V inlay did not show better results than the direct filling technique. However, postcured inlays performed better than their non-postcured counterparts. Without etching enamel with a phosphoric acid gel, but by priming its surface, approximately 80% of "excellent margin" were found in enamel before thermal cycling. This percentage decreased significantly after thermal loading. Restorations totally confined to dentin had slightly lower percentages of "excellent margin" than the mixed class V fillings. The results of this study indicated, that by using dentinal adhesives, little changes and deviations from the correct procedure result in significant alterations in marginal adaptation.

  7. Concept of Sukha (comfort) mentioned in Dhatusarata (tissue excellence) w.s.r. to vocational guidance.

    PubMed

    Waghulade, Hemangini; Harit, Mahesh Kumar

    2014-01-01

    Agni (digestive fire), Prakruti (constitution), Dhatusarata (tissue excellence), Dosha (bio-energies) are the specialties of Ayurveda on which diagnosis, treatment and research are based. The description of Dhatusarata (tissue excellence) has been given under Dashavidha Pariksha (tenfold examination) in Charak Samhita, Viman Sthana, 8(th) chapter. Some qualities, which are mentioned in Dhatusarata are difficult to assess, e.g. Sukha, Aishwarya, Upabhoga, Bala, etc., There is a need to develop some quantitative parameters to measure these qualities according to tissue excellence i.e. Dhatusarata. By assessing Dhatu Sarata, one can judge the true strength of a particular Dhatu but only the ability or strength is not enough to get success; the liking or interest is also essential to achieve success. The purpose of this study is to elaborate the concept of Dhatusarata and reveal different aspects of Sukha according to the quality of that particular Dhatu in context of vocational guidance. It will help to establish interrelationship between Dhatusarata and vocational guidance. It will be assessed whether this Sukha quality is merely happiness or having different shades according to the excellence of Dhatus and whether this study is useful in guiding the person to choose appropriate profession, which will be according to his liking and ability. It has been concluded that shades of Sukha quality varies with particular Dhatusaras, which may be helpful in guiding a suitable profession to an individual which will be according to his ability and liking i.e. Sukha for intimate success.

  8. A quartz nanopillar hemocytometer for high-yield separation and counting of CD4+ T lymphocytes

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Joo; Seol, Jin-Kyeong; Wu, Yu; Ji, Seungmuk; Kim, Gil-Sung; Hyung, Jung-Hwan; Lee, Seung-Yong; Lim, Hyuneui; Fan, Rong; Lee, Sang-Kwon

    2012-03-01

    We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting.We report the development of a novel quartz nanopillar (QNP) array cell separation system capable of selectively capturing and isolating a single cell population including primary CD4+ T lymphocytes from the whole pool of splenocytes. Integrated with a photolithographically patterned hemocytometer structure, the streptavidin (STR)-functionalized-QNP (STR-QNP) arrays allow for direct quantitation of captured cells using high content imaging. This technology exhibits an excellent separation yield (efficiency) of ~95.3 +/- 1.1% for the CD4+ T lymphocytes from the mouse splenocyte suspensions and good linear response for quantitating captured CD4+ T-lymphoblasts, which is comparable to flow cytometry and outperforms any non-nanostructured surface capture techniques, i.e. cell panning. This nanopillar hemocytometer represents a simple, yet efficient cell capture and counting technology and may find immediate applications for diagnosis and immune monitoring in the point-of-care setting. Electronic supplementary information (ESI) available. See DOI: 10.1039/c2nr11338d

  9. Capillary zone electrophoresis method for a highly glycosylated and sialylated recombinant protein: development, characterization and application for process development.

    PubMed

    Zhang, Le; Lawson, Ken; Yeung, Bernice; Wypych, Jette

    2015-01-06

    A purity method based on capillary zone electrophoresis (CZE) has been developed for the separation of isoforms of a highly glycosylated protein. The separation was found to be driven by the number of sialic acids attached to each isoform. The method has been characterized using orthogonal assays and shown to have excellent specificity, precision and accuracy. We have demonstrated the CZE method is a useful in-process assay to support cell culture and purification development of this glycoprotein. Compared to isoelectric focusing (IEF), the CZE method provides more quantitative results and higher sample throughput with excellent accuracy, qualities that are required for process development. In addition, the CZE method has been applied in the stability testing of purified glycoprotein samples.

  10. Testing of a Fiber Optic Wear, Erosion and Regression Sensor

    NASA Technical Reports Server (NTRS)

    Korman, Valentin; Polzin, Kurt A.

    2011-01-01

    The nature of the physical processes and harsh environments associated with erosion and wear in propulsion environments makes their measurement and real-time rate quantification difficult. A fiber optic sensor capable of determining the wear (regression, erosion, ablation) associated with these environments has been developed and tested in a number of different applications to validate the technique. The sensor consists of two fiber optics that have differing attenuation coefficients and transmit light to detectors. The ratio of the two measured intensities can be correlated to the lengths of the fiber optic lines, and if the fibers and the host parent material in which they are embedded wear at the same rate the remaining length of fiber provides a real-time measure of the wear process. Testing in several disparate situations has been performed, with the data exhibiting excellent qualitative agreement with the theoretical description of the process and when a separate calibrated regression measurement is available good quantitative agreement is obtained as well. The light collected by the fibers can also be used to optically obtain the spectra and measure the internal temperature of the wear layer.

  11. Quantitative Magnetic Particle Imaging Monitors the Transplantation, Biodistribution, and Clearance of Stem Cells In Vivo

    PubMed Central

    Zheng, Bo; von See, Marc P.; Yu, Elaine; Gunel, Beliz; Lu, Kuan; Vazin, Tandis; Schaffer, David V.; Goodwill, Patrick W.; Conolly, Steven M.

    2016-01-01

    Stem cell therapies have enormous potential for treating many debilitating diseases, including heart failure, stroke and traumatic brain injury. For maximal efficacy, these therapies require targeted cell delivery to specific tissues followed by successful cell engraftment. However, targeted delivery remains an open challenge. As one example, it is common for intravenous deliveries of mesenchymal stem cells (MSCs) to become entrapped in lung microvasculature instead of the target tissue. Hence, a robust, quantitative imaging method would be essential for developing efficacious cell therapies. Here we show that Magnetic Particle Imaging (MPI), a novel technique that directly images iron-oxide nanoparticle-tagged cells, can longitudinally monitor and quantify MSC administration in vivo. MPI offers near-ideal image contrast, depth penetration, and robustness; these properties make MPI both ultra-sensitive and linearly quantitative. Here, we imaged, for the first time, the dynamic trafficking of intravenous MSC administrations using MPI. Our results indicate that labeled MSC injections are immediately entrapped in lung tissue and then clear to the liver within one day, whereas standard iron oxide particle (Resovist) injections are immediately taken up by liver and spleen. Longitudinal MPI-CT imaging also indicated a clearance half-life of MSC iron oxide labels in the liver at 4.6 days. Finally, our ex vivo MPI biodistribution measurements of iron in liver, spleen, heart, and lungs after injection showed excellent agreement (R2 = 0.943) with measurements from induction coupled plasma spectrometry. These results demonstrate that MPI offers strong utility for noninvasively imaging and quantifying the systemic distribution of cell therapies and other therapeutic agents. PMID:26909106

  12. Absolute quantitation of NAPQI-modified rat serum albumin by LC-MS/MS: monitoring acetaminophen covalent binding in vivo.

    PubMed

    LeBlanc, André; Shiao, Tze Chieh; Roy, René; Sleno, Lekha

    2014-09-15

    Acetaminophen is known to cause hepatoxicity via the formation of a reactive metabolite, N-acetyl p-benzoquinone imine (NAPQI), as a result of covalent binding to liver proteins. Serum albumin (SA) is known to be covalently modified by NAPQI and is present at high concentrations in the bloodstream and is therefore a potential biomarker to assess the levels of protein modification by NAPQI. A newly developed method for the absolute quantitation of serum albumin containing NAPQI covalently bound to its active site cysteine (Cys34) is described. This optimized assay represents the first absolute quantitation of a modified protein, with very low stoichiometric abundance, using a protein-level standard combined with isotope dilution. The LC-MS/MS assay is based on a protein standard modified with a custom-designed reagent, yielding a surrogate peptide (following digestion) that is a positional isomer to the target peptide modified by NAPQI. To illustrate the potential of this approach, the method was applied to quantify NAPQI-modified SA in plasma from rats dosed with acetaminophen. The resulting method is highly sensitive (capable of quantifying down to 0.0006% of total RSA in its NAPQI-modified form) and yields excellent precision and accuracy statistics. A time-course pharmacokinetic study was performed to test the usefulness of this method for following acetaminophen-induced covalent binding at four dosing levels (75-600 mg/kg IP), showing the viability of this approach to directly monitor in vivo samples. This approach can reliably quantify NAPQI-modified albumin, allowing direct monitoring of acetaminophen-related covalent binding.

  13. Analysis of artifacts suggests DGGE should not be used for quantitative diversity analysis.

    PubMed

    Neilson, Julia W; Jordan, Fiona L; Maier, Raina M

    2013-03-01

    PCR-denaturing gradient gel electrophoresis (PCR-DGGE) is widely used in microbial ecology for the analysis of comparative community structure. However, artifacts generated during PCR-DGGE of mixed template communities impede the application of this technique to quantitative analysis of community diversity. The objective of the current study was to employ an artificial bacterial community to document and analyze artifacts associated with multiband signatures and preferential template amplification and to highlight their impacts on the use of this technique for quantitative diversity analysis. Six bacterial species (three Betaproteobacteria, two Alphaproteobacteria, and one Firmicutes) were amplified individually and in combinations with primers targeting the V7/V8 region of the 16S rRNA gene. Two of the six isolates produced multiband profiles demonstrating that band number does not correlate directly with α-diversity. Analysis of the multiple bands from one of these isolates confirmed that both bands had identical sequences which lead to the hypothesis that the multiband pattern resulted from two distinct structural conformations of the same amplicon. In addition, consistent preferential amplification was demonstrated following pairwise amplifications of the six isolates. DGGE and real time PCR analysis identified primer mismatch and PCR inhibition due to 16S rDNA secondary structure as the most probable causes of preferential amplification patterns. Reproducible DGGE community profiles generated in this study confirm that PCR-DGGE provides an excellent high-throughput tool for comparative community structure analysis, but that method-specific artifacts preclude its use for accurate comparative diversity analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Rapid screening of the antimicrobial efficacy of Ag zeolites.

    PubMed

    Tosheva, L; Belkhair, S; Gackowski, M; Malic, S; Al-Shanti, N; Verran, J

    2017-09-01

    A semi-quantitative screening method was used to compare the killing efficacy of Ag zeolites against bacteria and yeast as a function of the zeolite type, crystal size and concentration. The method, which substantially reduced labor, consumables and waste and provided an excellent preliminary screen, was further validated by quantitative plate count experiments. Two pairs of zeolite X and zeolite beta with different sizes (ca. 200nm and 2μm for zeolite X and ca. 250 and 500nm for zeolite beta) were tested against Escherichia coli (E. coli) and Candida albicans (C. albicans) at concentrations in the range 0.05-0.5mgml -1 . Reduction of the zeolite crystal size resulted in a decrease in the killing efficacy against both microorganisms. The semi-quantitative tests allowed convenient optimization of the zeolite concentrations to achieve targeted killing times. Zeolite beta samples showed higher activity compared to zeolite X despite their lower Ag content, which was attributed to the higher concentration of silver released from zeolite beta samples. Cytotoxicity measurements using peripheral blood mononuclear cells (PBMCs) indicated that Ag zeolite X was more toxic than Ag zeolite beta. However, the trends for the dependence of cytotoxicity on zeolite crystal size at different zeolite concentrations were different for the two zeolites and no general conclusions about zeolite cytotoxicity could be drawn from these experiments. This result indicates a complex relationship, requiring the necessity for individual cytotoxicity measurements for all antimicrobial applications based on the use of zeolites. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. In vivo characterization of tissue thermal properties of the kidney during local hyperthermia induced by MR-guided high-intensity focused ultrasound.

    PubMed

    Cornelis, François; Grenier, Nicolas; Moonen, Chrit T; Quesson, Bruno

    2011-08-01

    The purpose of this study was to evaluate quantitatively in vivo the tissue thermal properties during high-intensity focused ultrasound (HIFU) heating. For this purpose, a total of 52 localized sonications were performed in the kidneys of six pigs with HIFU monitored in real time by volumetric MR thermometry. The kidney perfusion was modified by modulation of the flow in the aorta by insertion of an inflatable angioplasty balloon. The resulting temperature data were analyzed using the bio-heat transfer model in order to validate the model under in vivo conditions and to estimate quantitatively the absorption (α), thermal diffusivity (D) and perfusion (w(b)) of renal tissue. An excellent correspondence was observed between the bio-heat transfer model and the experimental data. The absorption and thermal diffusivity were independent of the flow, with mean values (± standard deviation) of 20.7 ± 5.1 mm(3) K J(-1) and 0.23 ± 0.11 mm(2) s(-1), respectively, whereas the perfusion decreased significantly by 84% (p < 0.01) with arterial flow (mean values of w(b) of 0.06 ± 0.02 and 0.008 ± 0.007 mL(-1) mL s(-1)), as predicted by the model. The quantitative analysis of the volumetric temperature distribution during nondestructive HIFU sonication allows the determination of the thermal parameters, and may therefore improve the quality of the planning of noninvasive therapy with MR-guided HIFU. Copyright © 2010 John Wiley & Sons, Ltd.

  16. A high-throughput urinalysis of abused drugs based on a SPE-LC-MS/MS method coupled with an in-house developed post-analysis data treatment system.

    PubMed

    Cheng, Wing-Chi; Yau, Tsan-Sang; Wong, Ming-Kei; Chan, Lai-Ping; Mok, Vincent King-Kuen

    2006-10-16

    A rapid urinalysis system based on SPE-LC-MS/MS with an in-house post-analysis data management system has been developed for the simultaneous identification and semi-quantitation of opiates (morphine, codeine), methadone, amphetamines (amphetamine, methylamphetamine (MA), 3,4-methylenedioxyamphetamine (MDA) and 3,4-methylenedioxymethamphetamine (MDMA)), 11-benzodiazepines or their metabolites and ketamine. The urine samples are subjected to automated solid phase extraction prior to analysis by LC-MS (Finnigan Surveyor LC connected to a Finnigan LCQ Advantage) fitted with an Alltech Rocket Platinum EPS C-18 column. With a single point calibration at the cut-off concentration for each analyte, simultaneous identification and semi-quantitation for the above mentioned drugs can be achieved in a 10 min run per urine sample. A computer macro-program package was developed to automatically retrieve appropriate data from the analytical data files, compare results with preset values (such as cut-off concentrations, MS matching scores) of each drug being analyzed and generate user-defined Excel reports to indicate all positive and negative results in batch-wise manner for ease of checking. The final analytical results are automatically copied into an Access database for report generation purposes. Through the use of automation in sample preparation, simultaneous identification and semi-quantitation by LC-MS/MS and a tailored made post-analysis data management system, this new urinalysis system significantly improves the quality of results, reduces the post-data treatment time, error due to data transfer and is suitable for high-throughput laboratory in batch-wise operation.

  17. Listening to light scattering in turbid media: quantitative optical scattering imaging using photoacoustic measurements with one-wavelength illumination

    NASA Astrophysics Data System (ADS)

    Yuan, Zhen; Li, Xiaoqi; Xi, Lei

    2014-06-01

    Biomedical photoacoustic tomography (PAT), as a potential imaging modality, can visualize tissue structure and function with high spatial resolution and excellent optical contrast. It is widely recognized that the ability of quantitatively imaging optical absorption and scattering coefficients from photoacoustic measurements is essential before PAT can become a powerful imaging modality. Existing quantitative PAT (qPAT), while successful, has been focused on recovering absorption coefficient only by assuming scattering coefficient a constant. An effective method for photoacoustically recovering optical scattering coefficient is presently not available. Here we propose and experimentally validate such a method for quantitative scattering coefficient imaging using photoacoustic data from one-wavelength illumination. The reconstruction method developed combines conventional PAT with the photon diffusion equation in a novel way to realize the recovery of scattering coefficient. We demonstrate the method using various objects having scattering contrast only or both absorption and scattering contrasts embedded in turbid media. The listening-to-light-scattering method described will be able to provide high resolution scattering imaging for various biomedical applications ranging from breast to brain imaging.

  18. A method for three-dimensional quantitative observation of the microstructure of biological samples

    NASA Astrophysics Data System (ADS)

    Wang, Pengfei; Chen, Dieyan; Ma, Wanyun; Wu, Hongxin; Ji, Liang; Sun, Jialin; Lv, Danyu; Zhang, Lu; Li, Ying; Tian, Ning; Zheng, Jinggao; Zhao, Fengying

    2009-07-01

    Contemporary biology has developed into the era of cell biology and molecular biology, and people try to study the mechanism of all kinds of biological phenomena at the microcosmic level now. Accurate description of the microstructure of biological samples is exigent need from many biomedical experiments. This paper introduces a method for 3-dimensional quantitative observation on the microstructure of vital biological samples based on two photon laser scanning microscopy (TPLSM). TPLSM is a novel kind of fluorescence microscopy, which has excellence in its low optical damage, high resolution, deep penetration depth and suitability for 3-dimensional (3D) imaging. Fluorescent stained samples were observed by TPLSM, and afterward the original shapes of them were obtained through 3D image reconstruction. The spatial distribution of all objects in samples as well as their volumes could be derived by image segmentation and mathematic calculation. Thus the 3-dimensionally and quantitatively depicted microstructure of the samples was finally derived. We applied this method to quantitative analysis of the spatial distribution of chromosomes in meiotic mouse oocytes at metaphase, and wonderful results came out last.

  19. Rapid video-referenced ratings of reciprocal social behavior in toddlers: A twin study

    PubMed Central

    Marrus, Natasha; Glowinski, Anne L.; Jacob, Theodore; Klin, Ami; Jones, Warren; Drain, Caroline E.; Holzhauer, Kieran E.; Hariprasad, Vaishnavi; Fitzgerald, Rob T.; Mortenson, Erika L.; Sant, Sayli M.; Cole, Lyndsey; Siegel, Satchel A.; Zhang, Yi; Agrawal, Arpana; Heath, Andrew; Constantino, John N.

    2015-01-01

    Background Reciprocal social behavior (RSB) is a developmental prerequisite for social competency, and deficits in RSB constitute a core feature of autism spectrum disorder (ASD). Although clinical screeners categorically ascertain risk of ASD in early childhood, rapid methods for quantitative measurement of RSB in toddlers are not yet established. Such measurements are critical for tracking developmental trajectories and incremental responses to intervention. Methods We developed and validated a 20-minute video-referenced rating scale, the video-referenced rating of reciprocal social behavior (vrRSB), for untrained caregivers to provide standardized ratings of quantitative variation in RSB. Parents of 252 toddler twins [Monozygotic (MZ)=31 pairs, Dizygotic (DZ)=95 pairs] ascertained through birth records, rated their twins’ RSB at two time points, on average 6 months apart, and completed two developmental measures, the Modified Checklist for Autism in Toddlers (M-CHAT) and the MacArthur Communicative Development Inventory Short Form (MCDI-s). Results Scores on the vrRSB were fully continuously distributed, with excellent 6-month test-retest reliability ([intraclass correlation coefficient] ICC=0.704, p<0.000). MZ twins displayed markedly greater trait concordance than DZ twins, (MZ ICC=0.863, p<0.000, DZ ICC=0.231, p<0.012). VrRSB score distributions were highly distinct for children passing versus failing the M-CHAT (t=−8.588, df=31, p<.000), incrementally improved from 18-24 months, and were inversely correlated with receptive and expressive vocabulary on the MCDI-s. Conclusions Like quantitative autistic trait ratings in school-aged children and adults, toddler scores on the vrRSB are continuously distributed and appear highly heritable. These ratings exhibited minimal measurement error, high inter-individual stability, and developmental progression in RSB as children matured from 18-24 months, supporting their potential utility for serially quantifying the severity of early autistic syndromes over time and in response to intervention. In addition, these findings inform the genetic-environmental structure of RSB in early typical development. PMID:25677414

  20. Lights on: Dye dequenching reveals polymersome fusion with polymer, lipid and stealth lipid vesicles

    DOE PAGES

    Henderson, Ian M.; Collins, Aaron M.; Quintana, Hope A.; ...

    2015-12-13

    In this study, we develop a quantitative dye dequenching technique for the measurement of polymersome fusion, using it to characterize the salt mediated, mechanically-induced fusion of polymersomes with polymer, lipid, and so-called stealth lipid vesicles. While dye dequenching has been used to quantitatively explore liposome fusion in the past, this is the first use of dye dequenching to measure polymersome fusion of which we are aware. In addition to providing quantitative results, dye dequenching is ideal for detecting fusion in instances where DLS results would be ambiguous, such as low yield levels and size ranges outside the capabilities of DLS.more » The dye chosen for this study was a cyanine derivative, 1,1'-dioctadecyl-3,3,3',3'-tetramethylindotricarbocyanine iodide (DiR), which proved to provide excellent data on the extent of polymersome fusion. Using this technique, we have shown the limited fusion capabilities of polymersome/liposome heterofusion, notably DOPC vesicles fusing with polymersomes at half the efficiency of polymersome homofusion and DPPC vesicles showing virtually no fusion. In addition to these key heterofusion experiments, we determined the broad applicability of dye dequenching in measuring kinetic rates of polymersome fusion; and showed that even at elevated temperatures or over multiple weeks' time, no polymersome fusion occurred without agitation. Stealth liposomes formed from DPPC and PEO-functionalized lipid, however, fused with polymersomes and stealth liposomes with relatively high efficiency, lending support to our hypothesis that the response of the PEO corona to salt is a key factor in the fusion process. This last finding suggests that although the conjugation of PEO to lipids increases vesicle biocompatibility and enables their longer circulation times, it also renders the vesicles subject to destabilization under high salt and shear (e.g. in the circulatory system) that may lead to, in this case, fusion.« less

  1. Direct Measurements of the Penetration Depth in a Superconducting Film using Magnetic Force Microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    E Nazaretski; J Thibodaux; I Vekhter

    2011-12-31

    We report the local measurements of the magnetic penetration depth in a superconducting Nb film using magnetic force microscopy (MFM). We developed a method for quantitative extraction of the penetration depth from single-parameter simultaneous fits to the lateral and height profiles of the MFM signal, and demonstrate that the obtained value is in excellent agreement with that obtained from the bulk magnetization measurements.

  2. An Exploratory Study of the United States Naval Academy Engineering Curriculum

    DTIC Science & Technology

    2007-06-01

    research was conducted in an entirely quantitative fashion. There is a large amount of qualitative data that was not analyzed. These data are from the... qualitative assessment of the Naval Academy’s engineering program, and would be an excellent opportunity for future research . Overall, the results of...California: Sage Publications. Patton, M. Q. (1987). How to Use Qualitative Methods in Evaluation. California: Sage Publications. 89

  3. Artificial Intelligence (Al) Center of Excellence at the University of Pennsylvania

    DTIC Science & Technology

    1995-07-01

    Approach and repel behaviors were implemented in order to study higher level behavioral simulation . Parallel algorithms for motion planning (as a...of decision-making accuracy can be specified for this graph-reduction process. We have also developed a mixed qualitative/quantitative simulation ...system, called QobiSIM. QobiSIM has been used to develop a cardiovascular simulation to be incorporated into the TraumAID system. This cardiovascular

  4. Center of Excellence for Remote and Medically Under-Served Areas

    DTIC Science & Technology

    2008-04-11

    was an experimental, quantitative , qualitative, descriptive research study related to audio, data and video transmission from the ambulance to the... posttest score. Both the pretest and posttest questions were generated randomly from a bank of XXX course-related test questions. The analysis below...shows the mean for the pretest , posttest , and difference scores for the classroom group, the virtual group, and the total group. (Note: Two of the

  5. Quantitative assessment of copper proteinates used as animal feed additives using ATR-FTIR spectroscopy and powder X-ray diffraction (PXRD) analysis.

    PubMed

    Cantwell, Caoimhe A; Byrne, Laurann A; Connolly, Cathal D; Hynes, Michael J; McArdle, Patrick; Murphy, Richard A

    2017-08-01

    The aim of the present work was to establish a reliable analytical method to determine the degree of complexation in commercial metal proteinates used as feed additives in the solid state. Two complementary techniques were developed. Firstly, a quantitative attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopic method investigated modifications in vibrational absorption bands of the ligand on complex formation. Secondly, a powder X-ray diffraction (PXRD) method to quantify the amount of crystalline material in the proteinate product was developed. These methods were developed in tandem and cross-validated with each other. Multivariate analysis (MVA) was used to develop validated calibration and prediction models. The FTIR and PXRD calibrations showed excellent linearity (R 2  > 0.99). The diagnostic model parameters showed that the FTIR and PXRD methods were robust with a root mean square error of calibration RMSEC ≤3.39% and a root mean square error of prediction RMSEP ≤7.17% respectively. Comparative statistics show excellent agreement between the MVA packages assessed and between the FTIR and PXRD methods. The methods can be used to determine the degree of complexation in complexes of both protein hydrolysates and pure amino acids.

  6. Profile of Scientific Ability of Chemistry Education Students in Basic Physics Course

    NASA Astrophysics Data System (ADS)

    Suastika, K. G.; Sudyana, I. N.; Lasiani, L.; Pebriyanto, Y.; Kurniawati, N.

    2017-09-01

    The weakness of scientific ability of students in college has been being a concern in this case, especially in terms of laboratory activities to support Laboratory Based Education. Scientific ability is a basic ability that must be dominated by students in basic physics lecturing process as a part of scientific method. This research aims to explore the indicators emergence of the scientific ability of students in Chemistry Education of Study Program, Faculty of Teaching and Education University of Palangka Raya through Inquiry Based Learning in basic physics courses. This research is a quantitative research by using descriptive method (descriptive-quantitative). Students are divided into three categories of group those are excellent group, low group, and heterogeneous group. The result shows that the excellent group and low group have same case that were occured decreasing in the percentage of achievement of scientific ability, while in heterogeneous group was increased. The differentiation of these results are caused by enthusiastic level of students in every group that can be seen in tables of scientific ability achievement aspects. By the results of this research, hoping in the future can be a references for further research about innovative learning strategies and models that can improve scientific ability and scientific reasoning especially for science teacher candidates.

  7. Translocation of a heterogeneous polymer

    PubMed Central

    Mirigian, Stephen; Wang, Yanbo; Muthukumar, Murugappan

    2012-01-01

    We present results on the sequence dependence of translocation kinetics for a partially charged heteropolymer moving through a very thin pore using theoretical tools and Langevin dynamics simulational techniques. The chain is composed of two types of monomers of differing frictional interaction with the pore and charge. We present exact analytical expressions for passage probability, mean first passage time, and mean successful passage times for both reflecting/absorbing and absorbing/absorbing boundary conditions, showing rich and unexpected dependence of translocation behavior on charge fraction, distribution along the chain, and electric field configuration. We find excellent qualitative and good quantitative agreement between theoretical and simulation results. Surprisingly, there emerges a threshold charge fraction of a diblock copolymer beyond which the success rate of translocation is independent of charge fraction. Also, the mean successful translocation time of a diblock copolymer displays non-monotonic behavior with increasing length of the charged block; there is an optimum length of the charged block where the mean translocation rate is the slowest; and there can be a substantial range of higher charge fractions which make the translocation slower than even a minimally charged chain. Additionally, we find for a fixed total charge on the chain, finer distribution along the backbone significantly decreases mean translocation time. PMID:22897308

  8. Detection of central nervous system leukemia in children with acute lymphoblastic leukemia by real-time polymerase chain reaction.

    PubMed

    Pine, Sharon R; Yin, Changhong; Matloub, Yousif H; Sabaawy, Hatem E; Sandoval, Claudio; Levendoglu-Tugal, Oya; Ozkaynak, M Fevzi; Jayabose, Somasundaram

    2005-02-01

    Accurate detection of central nervous system (CNS) involvement in children with newly diagnosed acute lymphoblastic leukemia (ALL) could have profound prognostic and therapeutic implications. We examined various cerebrospinal fluid (CSF) preservation methods to yield adequate DNA stability for polymerase chain reaction (PCR) analysis and developed a quantitative real-time PCR assay to detect occult CNS leukemia. Sixty CSF specimens were maintained in several storage conditions for varying amounts of time, and we found that preserving CSF in 1:1 serum-free RPMI tissue culture medium offers the best stability of DNA for PCR analysis. Sixty CSF samples (30 at diagnosis and 30 at the end of induction therapy) from 30 children with ALL were tested for CNS leukemic involvement by real-time PCR using patient-specific antigen receptor gene rearrangement primers. Six of thirty patient diagnosis samples were PCR-positive at levels ranging from 0.5 to 66% leukemic blasts in the CSF. Four of these patients had no clinical or cytomorphological evidence of CNS leukemia involvement at that time. All 30 CSF samples drawn at the end of induction therapy were PCR-negative. The data indicate that real-time PCR analysis of CSF is an excellent tool to assess occult CNS leukemia involvement in patients with ALL and can possibly be used to refine CNS status classification.

  9. Detection of Central Nervous System Leukemia in Children with Acute Lymphoblastic Leukemia by Real-Time Polymerase Chain Reaction

    PubMed Central

    Pine, Sharon R.; Yin, Changhong; Matloub, Yousif H.; Sabaawy, Hatem E.; Sandoval, Claudio; Levendoglu-Tugal, Oya; Ozkaynak, M. Fevzi; Jayabose, Somasundaram

    2005-01-01

    Accurate detection of central nervous system (CNS) involvement in children with newly diagnosed acute lymphoblastic leukemia (ALL) could have profound prognostic and therapeutic implications. We examined various cerebrospinal fluid (CSF) preservation methods to yield adequate DNA stability for polymerase chain reaction (PCR) analysis and developed a quantitative real-time PCR assay to detect occult CNS leukemia. Sixty CSF specimens were maintained in several storage conditions for varying amounts of time, and we found that preserving CSF in 1:1 serum-free RPMI tissue culture medium offers the best stability of DNA for PCR analysis. Sixty CSF samples (30 at diagnosis and 30 at the end of induction therapy) from 30 children with ALL were tested for CNS leukemic involvement by real-time PCR using patient-specific antigen receptor gene rearrangement primers. Six of thirty patient diagnosis samples were PCR-positive at levels ranging from 0.5 to 66% leukemic blasts in the CSF. Four of these patients had no clinical or cytomorphological evidence of CNS leukemia involvement at that time. All 30 CSF samples drawn at the end of induction therapy were PCR-negative. The data indicate that real-time PCR analysis of CSF is an excellent tool to assess occult CNS leukemia involvement in patients with ALL and can possibly be used to refine CNS status classification. PMID:15681484

  10. Principles and Practices Fostering Inclusive Excellence: Lessons from the Howard Hughes Medical Institute’s Capstone Institutions

    PubMed Central

    DiBartolo, Patricia Marten; Gregg-Jolly, Leslie; Gross, Deborah; Manduca, Cathryn A.; Iverson, Ellen; Cooke, David B.; Davis, Gregory K.; Davidson, Cameron; Hertz, Paul E.; Hibbard, Lisa; Ireland, Shubha K.; Mader, Catherine; Pai, Aditi; Raps, Shirley; Siwicki, Kathleen; Swartz, Jim E.

    2016-01-01

    Best-practices pedagogy in science, technology, engineering, and mathematics (STEM) aims for inclusive excellence that fosters student persistence. This paper describes principles of inclusivity across 11 primarily undergraduate institutions designated as Capstone Awardees in Howard Hughes Medical Institute’s (HHMI) 2012 competition. The Capstones represent a range of institutional missions, student profiles, and geographical locations. Each successfully directed activities toward persistence of STEM students, especially those from traditionally underrepresented groups, through a set of common elements: mentoring programs to build community; research experiences to strengthen scientific skill/identity; attention to quantitative skills; and outreach/bridge programs to broaden the student pool. This paper grounds these program elements in learning theory, emphasizing their essential principles with examples of how they were implemented within institutional contexts. We also describe common assessment approaches that in many cases informed programming and created traction for stakeholder buy-in. The lessons learned from our shared experiences in pursuit of inclusive excellence, including the resources housed on our companion website, can inform others’ efforts to increase access to and persistence in STEM in higher education. PMID:27562960

  11. Improved Cerebral Time-of-Flight Magnetic Resonance Angiography at 7 Tesla – Feasibility Study and Preliminary Results Using Optimized Venous Saturation Pulses

    PubMed Central

    Wrede, Karsten H.; Johst, Sören; Dammann, Philipp; Özkan, Neriman; Mönninghoff, Christoph; Kraemer, Markus; Maderwald, Stefan; Ladd, Mark E.; Sure, Ulrich; Umutlu, Lale; Schlamann, Marc

    2014-01-01

    Purpose Conventional saturation pulses cannot be used for 7 Tesla ultra-high-resolution time-of-flight magnetic resonance angiography (TOF MRA) due to specific absorption rate (SAR) limitations. We overcome these limitations by utilizing low flip angle, variable rate selective excitation (VERSE) algorithm saturation pulses. Material and Methods Twenty-five neurosurgical patients (male n = 8, female n = 17; average age 49.64 years; range 26–70 years) with different intracranial vascular pathologies were enrolled in this trial. All patients were examined with a 7 Tesla (Magnetom 7 T, Siemens) whole body scanner system utilizing a dedicated 32-channel head coil. For venous saturation pulses a 35° flip angle was applied. Two neuroradiologists evaluated the delineation of arterial vessels in the Circle of Willis, delineation of vascular pathologies, presence of artifacts, vessel-tissue contrast and overall image quality of TOF MRA scans in consensus on a five-point scale. Normalized signal intensities in the confluence of venous sinuses, M1 segment of left middle cerebral artery and adjacent gray matter were measured and vessel-tissue contrasts were calculated. Results Ratings for the majority of patients ranged between good and excellent for most of the evaluated features. Venous saturation was sufficient for all cases with minor artifacts in arteriovenous malformations and arteriovenous fistulas. Quantitative signal intensity measurements showed high vessel-tissue contrast for confluence of venous sinuses, M1 segment of left middle cerebral artery and adjacent gray matter. Conclusion The use of novel low flip angle VERSE algorithm pulses for saturation of venous vessels can overcome SAR limitations in 7 Tesla ultra-high-resolution TOF MRA. Our protocol is suitable for clinical application with excellent image quality for delineation of various intracranial vascular pathologies. PMID:25232868

  12. Use of liquid chromatography coupled to quadrupole time-of-flight mass spectrometry to investigate pesticide residues in fruits.

    PubMed

    Grimalt, Susana; Pozo, Oscar J; Sancho, Juan V; Hernández, Félix

    2007-04-01

    In this paper, the potential of coupling liquid chromatography with hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF) for the determination of pesticides in a variety of fruit samples (orange peel and flesh, banana skin and flesh, strawberry and pear) has been explored. The quantitative application at residue levels has been proven for two insecticides (buprofezin and hexythiazox), which were satisfactorily determined at three concentration levels, 0.1, 1, and 5 mg/kg, obtaining a suitable linearity range (correlation coefficient>0.99) of more than 2 orders of magnitude. Satisfactory recoveries have been obtained for both compounds at the three levels tested in all sample matrices, with lowest calibration levels (LCL) of 0.075 and 0.01 mg/kg. The excellent potential of QTOF for identification purposes is illustrated by the high number of identification points (IPs) earned, up to 21, at the highest concentration of 5 mg/kg, or between 11 and 21 at the 0.1 and 1 mg/kg levels. The application of LC-QTOF MS to real samples revealed the presence of several positives at concentrations close to the LCL, all of which were confirmed with more than 11 IPs. The potential of QTOF for elucidation of nontarget analytes has also been demonstrated by the finding of one transformation product (TP) of buprofezin in a banana skin sample. This TP was identified by obtaining the full scan product ion spectra at different collision energies with acceptable accurate mass deviation. The work performed in this paper illustrates the suitability and excellent confirmatory potential of LC-QTOF MS for pesticides residues analysis in food samples.

  13. A rapid method for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet by ultra performance liquid chromatography-tandem mass spectrometry

    NASA Astrophysics Data System (ADS)

    Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan

    2013-05-01

    In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) <3%), were obtained. Comparison of system performance with traditional liquid chromatography-photo diode array detector (HPLC-PDA) was made with respect to analysis time, sensitivity, linearity and precisions. The proposed UPLC-MS/MS method was found to be reproducible and appropriate for quantitative analysis of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet.

  14. Development of an Excel-based laboratory information management system for improving workflow efficiencies in early ADME screening.

    PubMed

    Lu, Xinyan

    2016-01-01

    There is a clear requirement for enhancing laboratory information management during early absorption, distribution, metabolism and excretion (ADME) screening. The application of a commercial laboratory information management system (LIMS) is limited by complexity, insufficient flexibility, high costs and extended timelines. An improved custom in-house LIMS for ADME screening was developed using Excel. All Excel templates were generated through macros and formulae, and information flow was streamlined as much as possible. This system has been successfully applied in task generation, process control and data management, with a reduction in both labor time and human error rates. An Excel-based LIMS can provide a simple, flexible and cost/time-saving solution for improving workflow efficiencies in early ADME screening.

  15. Redesigning Schools to Reach Every Student with Excellent Teachers: Financial Planning for Time-Technology Swap--Rotation Model

    ERIC Educational Resources Information Center

    Public Impact, 2012

    2012-01-01

    This brief shows how teachers in a Time-Technology swap school model may earn more, sustainably. In this model, schools use age-appropriate portions of digital learning (as little as about an hour daily per student) to free the time of excellent teachers to teach more students and potentially to collaborate with peers. By teaching more students,…

  16. Exploring Middle School Students' and Parents' Conceptions of Excellent Teaching

    ERIC Educational Resources Information Center

    Chen, Junjun

    2016-01-01

    While there have been many western studies about what excellent teaching means, there are far fewer eastern studies. This study explored how students and parents perceived conceptions of excellent teaching in Chinese middle schools. The 77 students' and 67 parents' responses relating to a personal narrative of a time they had experienced excellent…

  17. Spectroscopic and Chemometric Analysis of Binary and Ternary Edible Oil Mixtures: Qualitative and Quantitative Study.

    PubMed

    Jović, Ozren; Smolić, Tomislav; Primožič, Ines; Hrenar, Tomica

    2016-04-19

    The aim of this study was to investigate the feasibility of FTIR-ATR spectroscopy coupled with the multivariate numerical methodology for qualitative and quantitative analysis of binary and ternary edible oil mixtures. Four pure oils (extra virgin olive oil, high oleic sunflower oil, rapeseed oil, and sunflower oil), as well as their 54 binary and 108 ternary mixtures, were analyzed using FTIR-ATR spectroscopy in combination with principal component and discriminant analysis, partial least-squares, and principal component regression. It was found that the composition of all 166 samples can be excellently represented using only the first three principal components describing 98.29% of total variance in the selected spectral range (3035-2989, 1170-1140, 1120-1100, 1093-1047, and 930-890 cm(-1)). Factor scores in 3D space spanned by these three principal components form a tetrahedral-like arrangement: pure oils being at the vertices, binary mixtures at the edges, and ternary mixtures on the faces of a tetrahedron. To confirm the validity of results, we applied several cross-validation methods. Quantitative analysis was performed by minimization of root-mean-square error of cross-validation values regarding the spectral range, derivative order, and choice of method (partial least-squares or principal component regression), which resulted in excellent predictions for test sets (R(2) > 0.99 in all cases). Additionally, experimentally more demanding gas chromatography analysis of fatty acid content was carried out for all specimens, confirming the results obtained by FTIR-ATR coupled with principal component analysis. However, FTIR-ATR provided a considerably better model for prediction of mixture composition than gas chromatography, especially for high oleic sunflower oil.

  18. Breast lesion shape and margin evaluation: BI-RADS based metrics understate radiologists' actual levels of agreement.

    PubMed

    Rawashdeh, Mohammad; Lewis, Sarah; Zaitoun, Maha; Brennan, Patrick

    2018-05-01

    While there is much literature describing the radiologic detection of breast cancer, there are limited data available on the agreement between experts when delineating and classifying breast lesions. The aim of this work is to measure the level of agreement between expert radiologists when delineating and classifying breast lesions as demonstrated through Breast Imaging Reporting and Data System (BI-RADS) and quantitative shape metrics. Forty mammographic images, each containing a single lesion, were presented to nine expert breast radiologists using a high specification interactive digital drawing tablet with stylus. Each reader was asked to manually delineate the breast masses using the tablet and stylus and then visually classify the lesion according to the American College of Radiology (ACR) BI-RADS lexicon. The delineated lesion compactness and elongation were computed using Matlab software. Intraclass Correlation Coefficient (ICC) and Cohen's kappa were used to assess inter-observer agreement for delineation and classification outcomes, respectively. Inter-observer agreement was fair for BI-RADS shape (kappa = 0.37) and moderate for margin (kappa = 0.58) assessments. Agreement for quantitative shape metrics was good for lesion elongation (ICC = 0.82) and excellent for compactness (ICC = 0.93). Fair to moderate levels of agreement was shown by radiologists for shape and margin classifications of cancers using the BI-RADS lexicon. When quantitative shape metrics were used to evaluate radiologists' delineation of lesions, good to excellent inter-observer agreement was found. The results suggest that qualitative descriptors such as BI-RADS lesion shape and margin understate the actual level of expert radiologist agreement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Simple and ultra-fast recognition and quantitation of compounded monoclonal antibodies: Application to flow injection analysis combined to UV spectroscopy and matching method.

    PubMed

    Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E

    2018-09-01

    Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Quantitation of anticonvulsant drugs in serum by gas-chromatography on the stationary phase SP-2510.

    PubMed

    Godolphin, W; Thoma, J

    1978-03-01

    A new column packing, SP-2510 DA (Supelco, Inc., Bellefonte, Pa. 16823), is an excellent stationary phase for the determination of a wide variety of anticonvulsant drugs by gas--liquid chromatography without derivatization. However, when uncomplicated extraction procedures are used, serum cholesterol interferes with the determination of primidone. By the simple expedient of adding a short "pre-column" containing another phase (SP-2250 DA) the problem is overcome.

  1. Simultaneous Quantitative MRI Mapping of T1, T2* and Magnetic Susceptibility with Multi-Echo MP2RAGE

    PubMed Central

    Kober, Tobias; Möller, Harald E.; Schäfer, Andreas

    2017-01-01

    The knowledge of relaxation times is essential for understanding the biophysical mechanisms underlying contrast in magnetic resonance imaging. Quantitative experiments, while offering major advantages in terms of reproducibility, may benefit from simultaneous acquisitions. In this work, we demonstrate the possibility of simultaneously recording relaxation-time and susceptibility maps with a prototype Multi-Echo (ME) Magnetization-Prepared 2 RApid Gradient Echoes (MP2RAGE) sequence. T1 maps can be obtained using the MP2RAGE sequence, which is relatively insensitive to inhomogeneities of the radio-frequency transmit field, B1+. As an extension, multiple gradient echoes can be acquired in each of the MP2RAGE readout blocks, which permits the calculation of T2* and susceptibility maps. We used computer simulations to explore the effects of the parameters on the precision and accuracy of the mapping. In vivo parameter maps up to 0.6 mm nominal resolution were acquired at 7 T in 19 healthy volunteers. Voxel-by-voxel correlations and the test-retest reproducibility were used to assess the reliability of the results. When using optimized paramenters, T1 maps obtained with ME-MP2RAGE and standard MP2RAGE showed excellent agreement for the whole range of values found in brain tissues. Simultaneously obtained T2* and susceptibility maps were of comparable quality as Fast Low-Angle SHot (FLASH) results. The acquisition times were more favorable for the ME-MP2RAGE (≈ 19 min) sequence as opposed to the sum of MP2RAGE (≈ 12 min) and FLASH (≈ 10 min) acquisitions. Without relevant sacrifice in accuracy, precision or flexibility, the multi-echo version may yield advantages in terms of reduced acquisition time and intrinsic co-registration, provided that an appropriate optimization of the acquisition parameters is performed. PMID:28081157

  2. Materials testing protocol for small joint prostheses.

    PubMed

    Savory, K M; Hutchinson, D T; Bloebaum, R

    1994-10-01

    In this article, a protocol for the evaluation of new materials for small joint prostheses is introduced. The testing methods employed in the protocol were developed by reviewing reported clinical failure modes and conditions found in vivo. The methods developed quantitatively evaluates the fatigue, fatigue crack propagation, and wear resistance properties of materials. For this study, a silicone elastomer similar to Dow Corning Silastic HP100, a radiation stable polypropylene, and a copolymer of polypropylene and ethylene propylene-diene monomer (EPDM) are evaluated. None of the materials tested demonstrated the ideal properties that are sought in a self-hinging joint prostheses. The silicone elastomer had excellent wear properties; however, cracks quickly propagated, causing catastrophic failure when fatigued. Conversely, the copolymer showed excellent fatigue crack propagation resistance and less than favorable wear properties. The polypropylene did not perform well in any evaluation.

  3. Time-varying output performances of piezoelectric vibration energy harvesting under nonstationary random vibrations

    NASA Astrophysics Data System (ADS)

    Yoon, Heonjun; Kim, Miso; Park, Choon-Su; Youn, Byeng D.

    2018-01-01

    Piezoelectric vibration energy harvesting (PVEH) has received much attention as a potential solution that could ultimately realize self-powered wireless sensor networks. Since most ambient vibrations in nature are inherently random and nonstationary, the output performances of PVEH devices also randomly change with time. However, little attention has been paid to investigating the randomly time-varying electroelastic behaviors of PVEH systems both analytically and experimentally. The objective of this study is thus to make a step forward towards a deep understanding of the time-varying performances of PVEH devices under nonstationary random vibrations. Two typical cases of nonstationary random vibration signals are considered: (1) randomly-varying amplitude (amplitude modulation; AM) and (2) randomly-varying amplitude with randomly-varying instantaneous frequency (amplitude and frequency modulation; AM-FM). In both cases, this study pursues well-balanced correlations of analytical predictions and experimental observations to deduce the relationships between the time-varying output performances of the PVEH device and two primary input parameters, such as a central frequency and an external electrical resistance. We introduce three correlation metrics to quantitatively compare analytical prediction and experimental observation, including the normalized root mean square error, the correlation coefficient, and the weighted integrated factor. Analytical predictions are in an excellent agreement with experimental observations both mechanically and electrically. This study provides insightful guidelines for designing PVEH devices to reliably generate electric power under nonstationary random vibrations.

  4. SU-G-IeP1-06: Estimating Relative Tissue Density From Quantitative MR Images: A Novel Perspective for MRI-Only Heterogeneity Corrected Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soliman, A; Hashemi, M; Safigholi, H

    Purpose: To explore the feasibility of extracting the relative density from quantitative MRI measurements as well as estimate a correlation between the extracted measures and CT Hounsfield units. Methods: MRI has the ability to separate water and fat signals, producing two separate images for each component. By performing appropriate corrections on the separated images, quantitative measurement of water and fat mass density can be estimated. This work aims to test this hypothesis on 1.5T.Peanut oil was used as fat-representative, while agar as water-representative. Gadolinium Chloride III and Sodium Chloride were added to the agar solution to adjust the relaxation timesmore » and the medium conductivity, respectively. Peanut oil was added to the agar solution with different percentages: 0%, 3%, 5%, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100%. The phantom was scanned on 1.5T GE Optima 450W with the body coil using a multigradient echo sequences. Water/fat separation were performed while correcting for main field (B0) inhomogeneity and T{sub 2}* relaxation time. B1+ inhomogeneities were ignored. The phantom was subsequently scanned on a Philips Brilliance CT Big Bore. MR-corrected fat signal from all vials were normalized to 100% fat signal. CT Hounsfield values were then compared to those obtained from the normalized MR-corrected fat values as well as to the phantom for validation. Results: Good agreement were found between CT HU and the MR-extracted fat values (R{sup 2} = 0.98). CT HU also showed excellent agreement with the prepared fat fractions (R{sup 2}=0.99). Vials with 70%, 80%, and 90% fat percentages showed inhomogeneous distributions, however their results were included for completion. Conclusion: Quantitative MRI water/fat imaging can be potentially used to extract the relative tissue density. Further in-vivo validation are required.« less

  5. Rapid Trace Detection and Isomer Quantitation of Pesticide Residues via Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    PubMed

    Wu, Xinzhou; Li, Weifeng; Guo, Pengran; Zhang, Zhixiang; Xu, Hanhong

    2018-04-18

    Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) has been applied for rapid, sensitive, undisputed, and quantitative detection of pesticide residues on fresh leaves with little sample pretreatment. Various pesticides (insecticides, bactericides, herbicides, and acaricides) are detected directly in the complex matrix with excellent limits of detection down to 4 μg/L. FTICR-MS could unambiguously identify pesticides with tiny mass differences (∼0.017 75 Da), thereby avoiding false-positive results. Remarkably, pesticide isomers can be totally discriminated by use of diagnostic fragments, and quantitative analysis of pesticide isomers is demonstrated. The present results expand the horizons of the MALDI-FTICR-MS platform in the reliable determination of pesticides, with integrated advantages of ultrahigh mass resolution and accuracy. This method provides growing evidence for the resultant detrimental effects of pesticides, expediting the identification and evaluation of innovative pesticides.

  6. Quantitative Measurement of Local Infrared Absorption and Dielectric Function with Tip-Enhanced Near-Field Microscopy.

    PubMed

    Govyadinov, Alexander A; Amenabar, Iban; Huth, Florian; Carney, P Scott; Hillenbrand, Rainer

    2013-05-02

    Scattering-type scanning near-field optical microscopy (s-SNOM) and Fourier transform infrared nanospectroscopy (nano-FTIR) are emerging tools for nanoscale chemical material identification. Here, we push s-SNOM and nano-FTIR one important step further by enabling them to quantitatively measure local dielectric constants and infrared absorption. Our technique is based on an analytical model, which allows for a simple inversion of the near-field scattering problem. It yields the dielectric permittivity and absorption of samples with 2 orders of magnitude improved spatial resolution compared to far-field measurements and is applicable to a large class of samples including polymers and biological matter. We verify the capabilities by determining the local dielectric permittivity of a PMMA film from nano-FTIR measurements, which is in excellent agreement with far-field ellipsometric data. We further obtain local infrared absorption spectra with unprecedented accuracy in peak position and shape, which is the key to quantitative chemometrics on the nanometer scale.

  7. [A quantitative risk assessment model of salmonella on carcass in poultry slaughterhouse].

    PubMed

    Zhang, Yu; Chen, Yuzhen; Hu, Chunguang; Zhang, Huaning; Bi, Zhenwang; Bi, Zhenqiang

    2015-05-01

    To construct a quantitative risk assessment model of salmonella on carcass in poultry slaughterhouse and to find out effective interventions to reduce salmonella contamination. We constructed a modular process risk model (MPRM) from evisceration to chilling in Excel Sheet using the data of the process parameters in poultry and the Salmomella concentration surveillance of Jinan in 2012. The MPRM was simulated by @ risk software. The concentration of salmonella on carcass after chilling was 1.96MPN/g which was calculated by model. The sensitive analysis indicated that the correlation coefficient of the concentration of salmonella after defeathering and in chilling pool were 0.84 and 0.34,which were the primary factors to the concentration of salmonella on carcass after chilling. The study provided a quantitative assessment model structure for salmonella on carcass in poultry slaughterhouse. The risk manager could control the contamination of salmonella on carcass after chilling by reducing the concentration of salmonella after defeathering and in chilling pool.

  8. Quantum dots assisted laser desorption/ionization mass spectrometric detection of carbohydrates: qualitative and quantitative analysis.

    PubMed

    Bibi, Aisha; Ju, Huangxian

    2016-04-01

    A quantum dots (QDs) assisted laser desorption/ionization mass spectrometric (QDA-LDI-MS) strategy was proposed for qualitative and quantitative analysis of a series of carbohydrates. The adsorption of carbohydrates on the modified surface of different QDs as the matrices depended mainly on the formation of hydrogen bonding, which led to higher MS intensity than those with conventional organic matrix. The effects of QDs concentration and sample preparation method were explored for improving the selective ionization process and the detection sensitivity. The proposed approach offered a new dimension to the application of QDs as matrices for MALDI-MS research of carbohydrates. It could be used for quantitative measurement of glucose concentration in human serum with good performance. The QDs served as a matrix showed the advantages of low background, higher sensitivity, convenient sample preparation and excellent stability under vacuum. The QDs assisted LDI-MS approach has promising application to the analysis of carbohydrates in complex biological samples. Copyright © 2016 John Wiley & Sons, Ltd.

  9. Comparison of clinical semi-quantitative assessment of muscle fat infiltration with quantitative assessment using chemical shift-based water/fat separation in MR studies of the calf of post-menopausal women.

    PubMed

    Alizai, Hamza; Nardo, Lorenzo; Karampinos, Dimitrios C; Joseph, Gabby B; Yap, Samuel P; Baum, Thomas; Krug, Roland; Majumdar, Sharmila; Link, Thomas M

    2012-07-01

    The goal of this study was to compare the semi-quantitative Goutallier classification for fat infiltration with quantitative fat-fraction derived from a magnetic resonance imaging (MRI) chemical shift-based water/fat separation technique. Sixty-two women (age 61 ± 6 years), 27 of whom had diabetes, underwent MRI of the calf using a T1-weighted fast spin-echo sequence and a six-echo spoiled gradient-echo sequence at 3 T. Water/fat images and fat fraction maps were reconstructed using the IDEAL algorithm with T2* correction and a multi-peak model for the fat spectrum. Two radiologists scored fat infiltration on the T1-weighted images using the Goutallier classification in six muscle compartments. Spearman correlations between the Goutallier grades and the fat fraction were calculated; in addition, intra-observer and inter-observer agreement were calculated. A significant correlation between the clinical grading and the fat fraction values was found for all muscle compartments (P < 0.0001, R values ranging from 0.79 to 0.88). Goutallier grades 0-4 had a fat fraction ranging from 3.5 to 19%. Intra-observer and inter-observer agreement values of 0.83 and 0.81 were calculated for the semi-quantitative grading. Semi-quantitative grading of intramuscular fat and quantitative fat fraction were significantly correlated and both techniques had excellent reproducibility. However, the clinical grading was found to overestimate muscle fat. Fat infiltration of muscle commonly occurs in many metabolic and neuromuscular diseases. • Image-based semi-quantitative classifications for assessing fat infiltration are not well validated. • Quantitative MRI techniques provide an accurate assessment of muscle fat.

  10. PET-based compartmental modeling of (124)I-A33 antibody: quantitative characterization of patient-specific tumor targeting in colorectal cancer.

    PubMed

    Zanzonico, Pat; Carrasquillo, Jorge A; Pandit-Taskar, Neeta; O'Donoghue, Joseph A; Humm, John L; Smith-Jones, Peter; Ruan, Shutian; Divgi, Chaitanya; Scott, Andrew M; Kemeny, Nancy E; Fong, Yuman; Wong, Douglas; Scheinberg, David; Ritter, Gerd; Jungbluth, Achem; Old, Lloyd J; Larson, Steven M

    2015-10-01

    The molecular specificity of monoclonal antibodies (mAbs) directed against tumor antigens has proven effective for targeted therapy of human cancers, as shown by a growing list of successful antibody-based drug products. We describe a novel, nonlinear compartmental model using PET-derived data to determine the "best-fit" parameters and model-derived quantities for optimizing biodistribution of intravenously injected (124)I-labeled antitumor antibodies. As an example of this paradigm, quantitative image and kinetic analyses of anti-A33 humanized mAb (also known as "A33") were performed in 11 colorectal cancer patients. Serial whole-body PET scans of (124)I-labeled A33 and blood samples were acquired and the resulting tissue time-activity data for each patient were fit to a nonlinear compartmental model using the SAAM II computer code. Excellent agreement was observed between fitted and measured parameters of tumor uptake, "off-target" uptake in bowel mucosa, blood clearance, tumor antigen levels, and percent antigen occupancy. This approach should be generally applicable to antibody-antigen systems in human tumors for which the masses of antigen-expressing tumor and of normal tissues can be estimated and for which antibody kinetics can be measured with PET. Ultimately, based on each patient's resulting "best-fit" nonlinear model, a patient-specific optimum mAb dose (in micromoles, for example) may be derived.

  11. Recent applications of gas chromatography with high-resolution mass spectrometry.

    PubMed

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Automated unsupervised multi-parametric classification of adipose tissue depots in skeletal muscle

    PubMed Central

    Valentinitsch, Alexander; Karampinos, Dimitrios C.; Alizai, Hamza; Subburaj, Karupppasamy; Kumar, Deepak; Link, Thomas M.; Majumdar, Sharmila

    2012-01-01

    Purpose To introduce and validate an automated unsupervised multi-parametric method for segmentation of the subcutaneous fat and muscle regions in order to determine subcutaneous adipose tissue (SAT) and intermuscular adipose tissue (IMAT) areas based on data from a quantitative chemical shift-based water-fat separation approach. Materials and Methods Unsupervised standard k-means clustering was employed to define sets of similar features (k = 2) within the whole multi-modal image after the water-fat separation. The automated image processing chain was composed of three primary stages including tissue, muscle and bone region segmentation. The algorithm was applied on calf and thigh datasets to compute SAT and IMAT areas and was compared to a manual segmentation. Results The IMAT area using the automatic segmentation had excellent agreement with the IMAT area using the manual segmentation for all the cases in the thigh (R2: 0.96) and for cases with up to moderate IMAT area in the calf (R2: 0.92). The group with the highest grade of muscle fat infiltration in the calf had the highest error in the inner SAT contour calculation. Conclusion The proposed multi-parametric segmentation approach combined with quantitative water-fat imaging provides an accurate and reliable method for an automated calculation of the SAT and IMAT areas reducing considerably the total post-processing time. PMID:23097409

  13. Development of an ultrasensitive aptasensor for the detection of aflatoxin B1.

    PubMed

    Guo, Xiaodong; Wen, Fang; Zheng, Nan; Luo, Qiujiang; Wang, Haiwei; Wang, Hui; Li, Songli; Wang, Jiaqi

    2014-06-15

    Contamination of feed and food by aflatoxin B1 (AFB1), one of the most toxic of the mycotoxins, is a global concern. To prevent food safety scares, and avoid subsequent economic losses due to the recall of contaminated items, methods for the rapid, sensitive and specific detection of AFB1 at trace levels are much in demand. In this work, a simple, ultrasensitive, and reliable aptasensor is described for the detection of AFB1. An AFB1 aptamer was used as a molecular recognition probe, while its complementary DNA played a role as a signal generator for amplification by real-time quantitative polymerase chain reaction (PCR). Under optimal conditions, a wide linear detection range (5.0 × 10(-5) to 5.0 ng mL(-1)) was achieved, with a high sensitivity (limit of detection (LOD)=25 fg mL(-1)). In addition, the proposed aptasensor exhibited excellent specificity for AFB1 compared with eight other mycotoxins, with no obvious Ct value change. This aptasensor can also be used in quantifying AFB1 levels in Chinese wild rye hay samples and infant rice cereal samples, demonstrating satisfactory recoveries in the range of 88-127% and 94-119%, respectively. This detection technique has a significant potential for high-throughput, quantitative determination of mycotoxin levels in a large range of feeds and foods. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. A Computational Framework for Quantitative Evaluation of Movement during Rehabilitation

    NASA Astrophysics Data System (ADS)

    Chen, Yinpeng; Duff, Margaret; Lehrer, Nicole; Sundaram, Hari; He, Jiping; Wolf, Steven L.; Rikakis, Thanassis

    2011-06-01

    This paper presents a novel generalized computational framework for quantitative kinematic evaluation of movement in a rehabilitation clinic setting. The framework integrates clinical knowledge and computational data-driven analysis together in a systematic manner. The framework provides three key benefits to rehabilitation: (a) the resulting continuous normalized measure allows the clinician to monitor movement quality on a fine scale and easily compare impairments across participants, (b) the framework reveals the effect of individual movement components on the composite movement performance helping the clinician decide the training foci, and (c) the evaluation runs in real-time, which allows the clinician to constantly track a patient's progress and make appropriate adaptations to the therapy protocol. The creation of such an evaluation is difficult because of the sparse amount of recorded clinical observations, the high dimensionality of movement and high variations in subject's performance. We address these issues by modeling the evaluation function as linear combination of multiple normalized kinematic attributes y = Σwiφi(xi) and estimating the attribute normalization function φi(ṡ) by integrating distributions of idealized movement and deviated movement. The weights wi are derived from a therapist's pair-wise comparison using a modified RankSVM algorithm. We have applied this framework to evaluate upper limb movement for stroke survivors with excellent results—the evaluation results are highly correlated to the therapist's observations.

  15. A quantitative, comprehensive analytical model for ``fast'' magnetic reconnection in Hall MHD

    NASA Astrophysics Data System (ADS)

    Simakov, Andrei N.

    2008-11-01

    Magnetic reconnection in nature usually happens on fast (e.g. dissipation independent) time scales. While such scales have been observed computationally [1], a fundamental analytical model capable of explaining them has been lacking. Here, we propose such a quantitative model for 2D Hall MHD reconnection without a guide field. The model recovers the Sweet-Parker and the electron MHD [2] results in the appropriate limits of the ion inertial length, di, and is valid everywhere in between [3]. The model predicts the dissipation region aspect ratio and the reconnection rate Ez in terms of dissipation and inertial parameters, and has been found to be in excellent agreement with non-linear simulations. It confirms a number of long-standing empirical results and resolves several controversies. In particular, we find that both open X-point and elongated dissipation regions allow ``fast'' reconnection and that Ez depends on di. Moreover, when applied to electron-positron plasmas, the model demonstrates that fast dispersive waves are not instrumental for ``fast'' reconnection [4]. [1] J. Birn et al., J. Geophys. Res. 106, 3715 (2001). [2] L. Chac'on, A. N. Simakov, and A. Zocco, Phys. Rev. Lett. 99, 235001 (2007). [3] A. N. Simakov and L. Chac'on, submitted to Phys. Rev. Lett. [4] L. Chac'on, A. N. Simakov, V. Lukin, and A. Zocco, Phys. Rev. Lett. 101, 025003 (2008).

  16. Single-pair fluorescence resonance energy transfer analysis of mRNA transcripts for highly sensitive gene expression profiling in near real time.

    PubMed

    Peng, Zhiyong; Young, Brandon; Baird, Alison E; Soper, Steven A

    2013-08-20

    Expression analysis of mRNAs transcribed from certain genes can be used as important sources of biomarkers for in vitro diagnostics. While the use of reverse transcription quantitative PCR (RT-qPCR) can provide excellent analytical sensitivity for monitoring transcript numbers, more sensitive approaches for expression analysis that can report results in near real-time are needed for many critical applications. We report a novel assay that can provide exquisite limits-of-quantitation and consists of reverse transcription (RT) followed by a ligase detection reaction (LDR) with single-pair fluorescence resonance energy transfer (spFRET) to provide digital readout through molecular counting. For this assay, no PCR was employed, which enabled short assay turnaround times. To facilitate implementation of the assay, a cyclic olefin copolymer (COC) microchip, which was fabricated using hot embossing, was employed to carry out the LDR in a continuous flow format with online single-molecule detection following the LDR. As demonstrators of the assay's utility, MMP-7 mRNA was expression profiled from several colorectal cancer cell lines. It was found that the RT-LDR/spFRET assay produced highly linear calibration plots even in the low copy number regime. Comparison to RT-qPCR indicated a better linearity over the low copy number range investigated (10-10,000 copies) with an R(2) = 0.9995 for RT-LDR/spFRET and R(2) = 0.98 for RT-qPCR. In addition, differentiating between copy numbers of 10 and 50 could be performed with higher confidence using RT-LDR/spFRET. To demonstrate the short assay turnaround times obtainable using the RT-LDR/spFRET assay, a two thermal cycle LDR was carried out on amphiphysin gene transcripts that can serve as important diagnostic markers for ischemic stroke. The ability to supply diagnostic information on possible stroke events in short turnaround times using RT-LDR/spFRET will enable clinicians to treat patients effectively with appropriate time-sensitive therapeutics.

  17. Single-Pair Fret Analysis of mRNA Transcripts for Highly Sensitive Gene Expression Profiling in Near Real Time

    PubMed Central

    Peng, Zhiyong; Young, Brandon; Baird, Alison E.; Soper, Steven A.

    2013-01-01

    Expression analysis of mRNAs transcribed from certain genes can be used as important sources of biomarkers for in vitro diagnostics. While the use of reverse transcription quantitative PCR (RT-qPCR) can provide excellent analytical sensitivity for monitoring transcript numbers, more sensitive approaches for expression analysis that can report results in near real-time are needed for many critical applications. We report a novel assay that can provide exquisite limits-of-quantitation and consists of reverse transcription (RT) followed by a ligase detection reaction (LDR) with single-pair fluorescence resonance energy transfer (spFRET) to provide digital readout through molecular counting. For this assay, no PCR was employed, which enabled short assay turnaround times. To facilitate implementation of the assay, a cyclic olefin copolymer (COC) microchip, which was fabricated using hot embossing, was employed to carry out the LDR in a continuous flow format with on-line single-molecule detection following the LDR. As demonstrators of the assay's utility, MMP-7 mRNA was expression profiled from several colorectal cancer cell lines. It was found that the RT-LDR/spFRET assay produced highly linear calibration plots even in the low copy number regime. Comparison to RT-qPCR indicated a better linearity over the low copy number range investigated (10 − 10,000 copies) with an R2 = 0.9995 for RT-LDR/spFRET and R2 = 0.98 for RT-qPCR. In addition, differentiating between copy numbers of 10 and 50 could be performed with higher confidence using RT-LDR/spFRET. To demonstrate the short assay turnaround times obtainable using the RT-LDR/spFRET assay, a 2 thermal cycle LDR was carried out on amphiphysin gene transcripts that can serve as important diagnostic markers for ischemic stroke. The ability to supply diagnostic information on possible stroke events in short turnaround times using RT-LDR/spFRET will enable clinicians to treat patients effectively with appropriate time-sensitive therapeutics. PMID:23869556

  18. Multiplex, quantitative cellular analysis in large tissue volumes with clearing-enhanced 3D microscopy (Ce3D)

    PubMed Central

    Li, Weizhe; Germain, Ronald N.

    2017-01-01

    Organ homeostasis, cellular differentiation, signal relay, and in situ function all depend on the spatial organization of cells in complex tissues. For this reason, comprehensive, high-resolution mapping of cell positioning, phenotypic identity, and functional state in the context of macroscale tissue structure is critical to a deeper understanding of diverse biological processes. Here we report an easy to use method, clearing-enhanced 3D (Ce3D), which generates excellent tissue transparency for most organs, preserves cellular morphology and protein fluorescence, and is robustly compatible with antibody-based immunolabeling. This enhanced signal quality and capacity for extensive probe multiplexing permits quantitative analysis of distinct, highly intermixed cell populations in intact Ce3D-treated tissues via 3D histo-cytometry. We use this technology to demonstrate large-volume, high-resolution microscopy of diverse cell types in lymphoid and nonlymphoid organs, as well as to perform quantitative analysis of the composition and tissue distribution of multiple cell populations in lymphoid tissues. Combined with histo-cytometry, Ce3D provides a comprehensive strategy for volumetric quantitative imaging and analysis that bridges the gap between conventional section imaging and disassociation-based techniques. PMID:28808033

  19. Quantitative two-dimensional HSQC experiment for high magnetic field NMR spectrometers

    NASA Astrophysics Data System (ADS)

    Koskela, Harri; Heikkilä, Outi; Kilpeläinen, Ilkka; Heikkinen, Sami

    2010-01-01

    The finite RF power available on carbon channel in proton-carbon correlation experiments leads to non-uniform cross peak intensity response across carbon chemical shift range. Several classes of broadband pulses are available that alleviate this problem. Adiabatic pulses provide an excellent magnetization inversion over a large bandwidth, and very recently, novel phase-modulated pulses have been proposed that perform 90° and 180° magnetization rotations with good offset tolerance. Here, we present a study how these broadband pulses (adiabatic and phase-modulated) can improve quantitative application of the heteronuclear single quantum coherence (HSQC) experiment on high magnetic field strength NMR spectrometers. Theoretical and experimental examinations of the quantitative, offset-compensated, CPMG-adjusted HSQC (Q-OCCAHSQC) experiment are presented. The proposed experiment offers a formidable improvement to the offset performance; 13C offset-dependent standard deviation of the peak intensity was below 6% in range of ±20 kHz. This covers the carbon chemical shift range of 150 ppm, which contains the protonated carbons excluding the aldehydes, for 22.3 T NMR magnets. A demonstration of the quantitative analysis of a fasting blood plasma sample obtained from a healthy volunteer is given.

  20. Measurement of regional cerebral blood flow with copper-62-PTSM and a three-compartment model.

    PubMed

    Okazawa, H; Yonekura, Y; Fujibayashi, Y; Mukai, T; Nishizawa, S; Magata, Y; Ishizu, K; Tamaki, N; Konishi, J

    1996-07-01

    We evaluated quantitatively 62Cu-labeled pyruvaldehyde bis(N4-methylthiosemicarbazone) copper II (62Cu-PTSM) as a brain perfusion tracer for positron emission tomography (PET). For quantitative measurement, the octanol extraction method is needed to correct for arterial radioactivity in estimating the lipophilic input function, but the procedure is not practical for clinical studies. To measure regional cerebral blood flow (rCBF) by 62Cu-PTSM with simple arterial blood sampling, a standard curve of the octanol extraction ratio and a three-compartment model were applied. We performed both 15O-labeled water PET and 62 Cu-PTSM PET with dynamic data acquisition and arterial sampling in six subjects. Data obtained in 10 subjects studied previously were used for the standard octanol extraction curve. Arterial activity was measured and corrected to obtain the true input function using the standard curve. Graphical analysis (Gjedde-Patlak plot) with the data for each subject fitted by a straight regression line suggested that 62Cu-PTSM can be analyzed by the three-compartment model with negligible K4. Using this model, K1-K3 were estimated from curve fitting of the cerebral time-activity curve and the corrected input function. The fractional uptake of 62Cu-PTSM was corrected to rCBF with the individual extraction at steady state calculated from K1-K3. The influx rates (Ki) obtained from three-compartment model and graphical analyses were compared for the validation of the model. A comparison of rCBF values obtained from 62Cu-PTSM and 150-water studies demonstrated excellent correlation. The results suggest the potential feasibility of quantitation of cerebral perfusion with 62Cu-PTSM accompanied by dynamic PET and simple arterial sampling.

  1. Skeletal muscle magnetic resonance biomarkers correlate with function and sentinel events in Duchenne muscular dystrophy.

    PubMed

    Barnard, Alison M; Willcocks, Rebecca J; Finanger, Erika L; Daniels, Michael J; Triplett, William T; Rooney, William D; Lott, Donovan J; Forbes, Sean C; Wang, Dah-Jyuu; Senesac, Claudia R; Harrington, Ann T; Finkel, Richard S; Russman, Barry S; Byrne, Barry J; Tennekoon, Gihan I; Walter, Glenn A; Sweeney, H Lee; Vandenborne, Krista

    2018-01-01

    To provide evidence for quantitative magnetic resonance (qMR) biomarkers in Duchenne muscular dystrophy by investigating the relationship between qMR measures of lower extremity muscle pathology and functional endpoints in a large ambulatory cohort using a multicenter study design. MR spectroscopy and quantitative imaging were implemented to measure intramuscular fat fraction and the transverse magnetization relaxation time constant (T2) in lower extremity muscles of 136 participants with Duchenne muscular dystrophy. Measures were collected at 554 visits over 48 months at one of three imaging sites. Fat fraction was measured in the soleus and vastus lateralis using MR spectroscopy, while T2 was assessed using MRI in eight lower extremity muscles. Ambulatory function was measured using the 10m walk/run, climb four stairs, supine to stand, and six minute walk tests. Significant correlations were found between all qMR and functional measures. Vastus lateralis qMR measures correlated most strongly to functional endpoints (|ρ| = 0.68-0.78), although measures in other rapidly progressing muscles including the biceps femoris (|ρ| = 0.63-0.73) and peroneals (|ρ| = 0.59-0.72) also showed strong correlations. Quantitative MR biomarkers were excellent indicators of loss of functional ability and correlated with qualitative measures of function. A VL FF of 0.40 was an approximate lower threshold of muscle pathology associated with loss of ambulation. Lower extremity qMR biomarkers have a robust relationship to clinically meaningful measures of ambulatory function in Duchenne muscular dystrophy. These results provide strong supporting evidence for qMR biomarkers and set the stage for their potential use as surrogate outcomes in clinical trials.

  2. STEREO: a program on a PC-Windows 95 platform for recording and evaluating quantitative stereologic investigations of multistage hepatocarcinogenesis in rodents.

    PubMed

    Xu, Y H; Dragan, Y P; Campbell, H A; Pitot, H C

    1998-04-01

    The most common organ site of neoplasms induced by carcinogenic chemicals in the rodent bioassay is the liver. The development of cancer in rodent liver is a multistage process involving sequentially the stages of initiation, promotion, and progression. During the stages of promotion and progression, numerous lesions termed altered hepatic foci (AHF) develop. STEREO was developed for the purpose of efficient and accurate quantitation of AHF and related lesions in experimental and test rodents. The system utilized is equipped with a microcomputer (IBM-compatible PC running Windows 95) and a Summagraphics MICROGRID or SummaSketch tablet digitizer. The program records information from digitization of single or serial sections obtained randomly from rat liver tissue. With this information and the methods of quantitative stereology, both the number and volume percentage fraction of AHF in liver are calculated in three dimensions. The recorded data files can be printed graphically or in the format of tabular numerical data. The results of stereologic calculations are stored on floppy disks and can be sorted into different categories and analyzed or displayed with the use of statistics and graphic functions built into the overall program. Results may also be exported into Microsoft Excel for use at a later time. Any IBM-compatible PC capable of utilizing Windows 95 and MS Office can be used with STEREO, which offers inexpensive, easily operated software to obtain three-dimensional information from sections of two dimensions for the identification and relative potency of initiators, promoters, and progressors, and for the establishment of information potentially useful in developing estimations of risk for human cancer.

  3. Modulation of renal oxygenation and perfusion in rat kidney monitored by quantitative diffusion and blood oxygen level dependent magnetic resonance imaging on a clinical 1.5T platform.

    PubMed

    Jerome, Neil P; Boult, Jessica K R; Orton, Matthew R; d'Arcy, James; Collins, David J; Leach, Martin O; Koh, Dow-Mu; Robinson, Simon P

    2016-10-03

    To investigate the combined use of intravoxel incoherent motion (IVIM) diffusion-weighted (DW) and blood oxygen level dependent (BOLD) magnetic resonance imaging (MRI) to assess rat renal function using a 1.5T clinical platform. Multiple b-value DW and BOLD MR images were acquired from adult rats using a parallel clinical coil arrangement, enabling quantitation of the apparent diffusion coefficient (ADC), IVIM-derived diffusion coefficient (D), pseudodiffusion coefficient (D*) and perfusion fraction (f), and the transverse relaxation time T 2 *, for whole kidney, renal cortex, and medulla. Following the acquisition of two baseline datasets to assess measurement repeatability, images were acquired following i.v. administration of hydralazine, furosemide, or angiotensin II for up to 40 min. Excellent repeatability (CoV <10 %) was observed for ADC, D, f and T 2 * measured over the whole kidney. Hydralazine induced a marked and significant (p < 0.05) reduction in whole kidney ADC, D, and T 2 *, and a significant (p < 0.05) increase in D* and f. Furosemide significantly (p < 0.05) increased whole kidney ADC, D, and T 2 *. A more variable response to angiotensin II was determined, with a significant (p < 0.05) increase in medulla D* and significant (p < 0.05) reduction in whole kidney T 2 * established. Multiparametric MRI, incorporating quantitation of IVIM DWI and BOLD biomarkers and performed on a clinical platform, can be used to monitor the acute effects of vascular and tubular modulating drugs on rat kidney function in vivo. Clinical adoption of such functional imaging biomarkers can potentially inform on treatment effects in patients with renal dysfunction.

  4. Quantitative Accelerated Life Testing of MEMS Accelerometers.

    PubMed

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-11-20

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing thereliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shownin this paper and an attempt to assess the reliability level for a batch of MEMSaccelerometers is reported. The testing plan is application-driven and contains combinedtests: thermal (high temperature) and mechanical stress. Two variants of mechanical stressare used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tiltingand high temperature is used. Tilting is appropriate as application-driven stress, because thetilt movement is a natural environment for devices used for automotive and aerospaceapplications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The testresults demonstrated the excellent reliability of the studied devices, the failure rate in the"worst case" being smaller than 10 -7 h -1 .

  5. Hamming's "open doors" and group creativity as keys to scientific excellence: the example of Cambridge.

    PubMed

    Erren, Thomas C

    2008-01-01

    Dr. Charlton used diverse approaches to identify research institutions which provided home to outstanding scientists and work. One intriguing example of long-lasting scientific excellence is Cambridge with 19 Nobel laureates who worked at the University or at the MRC Molecular Biology Unit when they received the prize between 1947 and 2006. With specific reference to Cambridge, I would like to complement the primarily quantitative assessment and offer considerations as to why and how research achievements may have clustered in space and time. Indeed, observations voiced by the mathematician Richard Hamming as to how great research can be pursued offer explanations for the series of great science in the UK. In my view, the most important determinant of the clustering may be illustrated by Hamming's fitting picture of "open doors": working in environments with the doors open allows constant interactions with peers with various disciplinary backgrounds, and thus fast avoidance of detours or dead ends in science and, ultimately, a focus on and the solution of problems of paramount, rather than of tangential, importance. Narrative insights into a strong argumentative tradition at Cambridge provided by Drs. Watson and Magueijo between 1968 and 2003 are in line with Hamming's suggestion and the value of group creativity. In the internet age with abundant interactions beyond home institutions we should not be surprised if clusters of great science were no longer confined to the usual suspect institutions which were awarded disproportionally with Nobel prizes in the past.

  6. Classical and quantum magnetism in giant Keplerate magnetic molecules.

    PubMed

    Müller, A; Luban, M; Schröder, C; Modler, R; Kögerler, P; Axenovich, M; Schnack, J; Canfield, P; Bud'ko, S; Harrison, N

    2001-09-17

    Complementary theoretical modeling methods are presented for the classical and quantum Heisenberg model to explain the magnetic properties of nanometer-sized magnetic molecules. Excellent quantitative agreement is achieved between our experimental data down to 0.1 K and for fields up to 60 Tesla and our theoretical results for the giant Keplerate species {Mo72Fe30}, by far the largest paramagnetic molecule synthesized to date. © 2001 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  7. Acquisition Leadership: An Opportunity Lost for Acquisition Excellence?

    DTIC Science & Technology

    2010-04-01

    Bryman , A. (1984). The debate about quantitative and qualitative research : A question of method or epistemology? The British Journal of Sociology, 35, 75...organization’s very way of “doing business ”—will prove a daunting task. The rationale for the research undertaken is that, by any standard, DoD is truly a...at the entry- and mid-levels to the AT&L Workforce? Method This article’s research question involves the importance of leadership training as part

  8. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases.

    PubMed

    Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F

    2016-05-01

    To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Development and evaluation of an up-converting phosphor technology-based lateral flow assay for rapid detection of Francisella tularensis.

    PubMed

    Hua, Fei; Zhang, Pingping; Zhang, Fuli; Zhao, Yong; Li, Chunfeng; Sun, Chongyun; Wang, Xiaochen; Yang, Ruifu; Wang, Chengbin; Yu, Ailian; Zhou, Lei

    2015-11-26

    Francisella tularensis is a potential biowarfare/bioterrorism agent and zoonotic pathogen that causes tularemia; thus, surveillance of F. tularensis and first-level emergency response using point-of-care testing (POCT) are essential. The UPT-LF POCT assay was established to quantitatively detect F. tularensis within 15 min, and the sensitivity of the assay was 10(4) CFU · mL(-1) (100 CFU/test). The linear quantitative range covered five orders of magnitude, and the coefficients of variation were less than 10%. Except Shigella dysenteriae, UPT-LF showed excellent specificity to four strains that are also potential biowarfare/bioterrorism agents and 13 food-borne pathogenic strains. Samples with pH 2-13, high ion strengths (≥ 2 mol · L(-1) solution of KCl and NaCl), high viscosities (≤ 50 mg · mL(-1) PEG20000 or ≥ 20% glycerol), and high concentrations of biomacromolecules (≥ 400 mg · mL(-1) bovine serum albumin or ≥ 80 mg · mL(-1) casein) showed little influence on the assay. For practical utilization, the tolerance limits for seven powders and eight viscera were determined, and operation errors of liquid measurement demonstrated a minor influence on the strip. Ftu-UPT-LF is a candidate POCT method because of its excellent sensitivity, specificity, and stability in complex samples, as well as low operation error.

  10. Ultra‐high performance supercritical fluid chromatography of lignin‐derived phenols from alkaline cupric oxide oxidation

    PubMed Central

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta

    2016-01-01

    Traditional chromatographic methods for the analysis of lignin‐derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra‐high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin‐derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5–2.5 μM, a limit of quantification of 2.5–5.0 μM, and a dynamic range of 5.0–2.0 mM (R 2 > 0.997). The new ultra‐high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin‐derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin‐derived phenols in complex environmental samples. PMID:27452148

  11. Laser speckle imaging allows real-time intraoperative blood flow assessment during neurosurgical procedures.

    PubMed

    Hecht, Nils; Woitzik, Johannes; König, Susanne; Horn, Peter; Vajkoczy, Peter

    2013-07-01

    Currently, there is no adequate technique for intraoperative monitoring of cerebral blood flow (CBF). To evaluate laser speckle imaging (LSI) for assessment of relative CBF, LSI was performed in 30 patients who underwent direct surgical revascularization for treatment of arteriosclerotic cerebrovascular disease (ACVD), Moyamoya disease (MMD), or giant aneurysms, and in 8 control patients who underwent intracranial surgery for reasons other than hemodynamic compromise. The applicability and sensitivity of LSI was investigated through baseline perfusion and CO2 reactivity testing. The dynamics of LSI were assessed during bypass test occlusion and flow initiation procedures. Laser speckle imaging permitted robust (pseudo-) quantitative assessment of relative microcirculatory flow and standard bypass grafting resulted in significantly higher postoperative baseline perfusion values in ACVD and MMD. The applicability and sensitivity of LSI was shown by a significantly reduced CO2 reactivity in ACVD (9.6±9%) and MMD (8.5±8%) compared with control (31.2±5%; P<0.0001). In high- and intermediate-flow bypass patients, LSI was characterized by a dynamic real-time response to acute perfusion changes and ultimately confirmed a sufficient flow substitution through the bypass graft. Thus, LSI can be used for sensitive and continuous, non-invasive real-time visualization and measurement of relative cortical CBF in excellent spatial-temporal resolution.

  12. Relaxometry model of strong dipolar perturbers for balanced-SSFP: application to quantification of SPIO loaded cells.

    PubMed

    Lebel, R Marc; Menon, Ravi S; Bowen, Chris V

    2006-03-01

    Magnetic resonance microscopy using magnetically labeled cells is an emerging discipline offering the potential for non-destructive studies targeting numerous cellular events in medical research. The present work develops a technique to quantify superparamagnetic iron-oxide (SPIO) loaded cells using fully balanced steady state free precession (b-SSFP) imaging. An analytic model based on phase cancellation was derived for a single particle and extended to predict mono-exponential decay versus echo time in the presence of multiple randomly distributed particles. Numerical models verified phase incoherence as the dominant contrast mechanism and evaluated the model using a full range of tissue decay rates, repetition times, and flip angles. Numerical simulations indicated a relaxation rate enhancement (DeltaR(2b)=0.412 gamma . LMD) proportional to LMD, the local magnetic dose (the additional sample magnetization due to the SPIO particles), a quantity related to the concentration of contrast agent. A phantom model of SPIO loaded cells showed excellent agreement with simulations, demonstrated comparable sensitivity to gradient echo DeltaR(*) (2) enhancements, and 14 times the sensitivity of spin echo DeltaR(2) measurements. We believe this model can be used to facilitate the generation of quantitative maps of targeted cell populations. Magn Reson Med, 2006. (c) 2006 Wiley-Liss, Inc.

  13. Performance Enhancement of the RatCAP Awake Rate Brain PET System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vaska, P.; Vaska, P.; Woody, C.

    The first full prototype of the RatCAP PET system, designed to image the brain of a rat while conscious, has been completed. Initial results demonstrated excellent spatial resolution, 1.8 mm FWHM with filtered backprojection and <1.5 mm FWHM with a Monte Carlo based MLEM method. However, noise equivalent countrate studies indicated the need for better timing to mitigate the effect of randoms. Thus, the front-end ASIC has been redesigned to minimize time walk, an accurate coincidence time alignment method has been implemented, and a variance reduction technique for the randoms is being developed. To maximize the quantitative capabilities required formore » neuroscience, corrections are being implemented and validated for positron range and photon noncollinearity, scatter (including outside the field of view), attenuation, randoms, and detector efficiency (deadtime is negligible). In addition, a more robust and compact PCI-based optical data acquisition system has been built to replace the original VME-based system while retaining the linux-based data processing and image reconstruction codes. Finally, a number of new animal imaging experiments have been carried out to demonstrate the performance of the RatCAP in real imaging situations, including an F-18 fluoride bone scan, a C-11 raclopride scan, and a dynamic C-11 methamphetamine scan.« less

  14. A Model of Pantun Learning to Develop Elementary Student’s Entrepreneurship Awareness

    NASA Astrophysics Data System (ADS)

    Asteria, P. V.; Yulianto, B.

    2018-01-01

    The principle of entrepreneurship should be instilled from an early age. Pantun is one of Indonesian local culture taught for the elementary school student. Therefore, this study aims to describe (1) the ability to understand the content from pantun based entrepreneurship, (2) the ability to determine the messages from pantun based entrepreneurship, and (3) the ability to apply the messages from pantun based entrepreneurship into their real life. The research type is descriptive quantitative and conducted on the subject of 35 students from SDN Margomulyo I Ngawi. The data is the student’s skill in reading comprehension from the pantun based entrepreneurship with the writing test items instrument. The results showed that the student’s ability to determine the content from pantun based entrepreneurship shows achievement by an average of 9.3 (include an excellent category) and the ability of students to determine the entrepreneurship messages by an average of 7.8 (good). Meanwhile, the average student’s ability to apply the entrepreneurship messages in pantun into their real life by an average of 8.7 (excellent). Overall, the student’s skill in reading comprehension from the pantun based entrepreneurship as a whole reached an average of 86.4 (excellent category).

  15. Comparison of clinical semi-quantitative assessment of muscle fat infiltration with quantitative assessment using chemical shift-based water/fat separation in MR studies of the calf of post-menopausal women

    PubMed Central

    Nardo, Lorenzo; Karampinos, Dimitrios C.; Joseph, Gabby B.; Yap, Samuel P.; Baum, Thomas; Krug, Roland; Majumdar, Sharmila; Link, Thomas M.

    2013-01-01

    Objective The goal of this study was to compare the semi-quantitative Goutallier classification for fat infiltration with quantitative fat-fraction derived from a magnetic resonance imaging (MRI) chemical shift-based water/fat separation technique. Methods Sixty-two women (age 61±6 years), 27 of whom had diabetes, underwent MRI of the calf using a T1-weighted fast spin-echo sequence and a six-echo spoiled gradient-echo sequence at 3 T. Water/fat images and fat fraction maps were reconstructed using the IDEAL algorithm with T2* correction and a multi-peak model for the fat spectrum. Two radiologists scored fat infiltration on the T1-weighted images using the Goutallier classification in six muscle compartments. Spearman correlations between the Goutallier grades and the fat fraction were calculated; in addition, intra-observer and inter-observer agreement were calculated. Results A significant correlation between the clinical grading and the fat fraction values was found for all muscle compartments (P<0.0001, R values ranging from 0.79 to 0.88). Goutallier grades 0–4 had a fat fraction ranging from 3.5 to 19%. Intra-observer and inter-observer agreement values of 0.83 and 0.81 were calculated for the semi-quantitative grading. Conclusion Semi-quantitative grading of intramuscular fat and quantitative fat fraction were significantly correlated and both techniques had excellent reproducibility. However, the clinical grading was found to overestimate muscle fat. PMID:22411305

  16. Quantitation of low molecular weight sugars by chemical derivatization-liquid chromatography/multiple reaction monitoring/mass spectrometry.

    PubMed

    Han, Jun; Lin, Karen; Sequria, Carita; Yang, Juncong; Borchers, Christoph H

    2016-07-01

    A new method for the separation and quantitation of 13 mono- and disaccharides has been developed by chemical derivatization/ultra-HPLC/negative-ion ESI-multiple-reaction monitoring MS. 3-Nitrophenylhydrazine (at 50°C for 60 min) was shown to be able to quantitatively derivatize low-molecular weight (LMW) reducing sugars. The nonreducing sugar, sucrose, was not derivatized. A pentafluorophenyl-bonded phase column was used for the chromatographic separation of the derivatized sugars. This method exhibits femtomole-level sensitivity, high precision (CVs of ≤ 4.6%) and high accuracy for the quantitation of LMW sugars in wine. Excellent linearity (R(2) ≥ 0.9993) and linear ranges of ∼500-fold for disaccharides and ∼1000-4000-fold for monosaccharides were achieved. With internal calibration ((13) C-labeled internal standards), recoveries were between 93.6% ± 1.6% (xylose) and 104.8% ± 5.2% (glucose). With external calibration, recoveries ranged from 82.5% ± 0.8% (ribulose) to 105.2% ± 2.1% (xylulose). Quantitation of sugars in two red wines and two white wines was performed using this method; quantitation of the central carbon metabolism-related carboxylic acids and tartaric acid was carried out using a previously established derivatization procedure with 3-nitrophenylhydrazine as well. The results showed that these two classes of compounds-both of which have important organoleptic properties-had different compositions in red and white wines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Experiment K305: Quantitative analysis of selected bone parameters. Supplement 3A: Trabecular spacing and orientation in the long bones

    NASA Technical Reports Server (NTRS)

    Judy, M. M.

    1981-01-01

    Values of mean trabecular spacing computed from optical diffraction patterns of 1:1 X-ray micrographs of tibial metaphysis and those obtained by standard image digitization techniques show excellent agreement. Upper limits on values of mean trabecular orientation deduced from diffraction patterns and the images are also in excellent agreement. Values of the ratio of mean trabecular spatial density in a region of 300 micrometers distal to the downwardly directed convexity in the cartilage growth plate to the value adjacent to the plate determined for flight animals sacrificed at recovery were significantly smaller than values for vivarium control animals. No significant differences were found in proximal regions. No significant differences in mean trabecular orientation were detected. Decreased values of trabecular spatial density and of both obsteoblastic activity and trabecular cross-sectional area noted in collateral researches suggest decreased modeling activity under weightlessness.

  18. Microscopic insights into the NMR relaxation based protein conformational entropy meter

    PubMed Central

    Kasinath, Vignesh; Sharp, Kim A.; Wand, A. Joshua

    2013-01-01

    Conformational entropy is a potentially important thermodynamic parameter contributing to protein function. Quantitative measures of conformational entropy are necessary for an understanding of its role but have been difficult to obtain. An empirical method that utilizes changes in conformational dynamics as a proxy for changes in conformational entropy has recently been introduced. Here we probe the microscopic origins of the link between conformational dynamics and conformational entropy using molecular dynamics simulations. Simulation of seven pro! teins gave an excellent correlation with measures of side-chain motion derived from NMR relaxation. The simulations show that the motion of methyl-bearing side-chains are sufficiently coupled to that of other side chains to serve as excellent reporters of the overall side-chain conformational entropy. These results tend to validate the use of experimentally accessible measures of methyl motion - the NMR-derived generalized order parameters - as a proxy from which to derive changes in protein conformational entropy. PMID:24007504

  19. Research on optical biosensor with up-converting phosphor marker

    NASA Astrophysics Data System (ADS)

    Zhao, Yongkai; Zhou, Lei; Wang, Jing; Huang, Lihua; Yan, Zhongqiang; Huang, Huijie; Yang, Ruifu; Liu, Lei; Ren, Bingqiang; Wang, Xiangzhao

    2006-08-01

    An optical biosensor with up-converting phosphor (UCP) marker is developed for the sensitive rapid immunoassay to the specific biomolecule. UCP can emit visible light when excited by infrared light. Through detecting and analyzing the content of UCP particles on the test strip after immunoreaction, the concentration of target analyte in the sample can be obtained. The detection sensitivity to plague IgG is better than 5 ng/ml; to plague FI-Ab is better than 100 pg/ml; to plague Yersinia pestis cell is better than 3*10^(4) CFU/ml. Good linear response characteristics and an excellent correlation (R2>=0.95) have been verified by quantitative detection results. In the practical application, detection results to 167 analytic samples have an excellent consistency with those obtained by reverse hemagglutination test. The up-converting phosphor technology (UPT) based biosensor has stable, reliable, and sensitive performances. It can meet the need of various bioassay applications.

  20. A regenerated electrochemical biosensor for label-free detection of glucose and urea based on conformational switch of i-motif oligonucleotide probe.

    PubMed

    Gao, Zhong Feng; Chen, Dong Mei; Lei, Jing Lei; Luo, Hong Qun; Li, Nian Bing

    2015-10-15

    Improving the reproducibility of electrochemical signal remains a great challenge over the past decades. In this work, i-motif oligonucleotide probe-based electrochemical DNA (E-DNA) sensor is introduced for the first time as a regenerated sensing platform, which enhances the reproducibility of electrochemical signal, for label-free detection of glucose and urea. The addition of glucose or urea is able to activate glucose oxidase-catalyzed or urease-catalyzed reaction, inducing or destroying the formation of i-motif oligonucleotide probe. The conformational switch of oligonucleotide probe can be recorded by electrochemical impedance spectroscopy. Thus, the difference of electron transfer resistance is utilized for the quantitative determination of glucose and urea. We further demonstrate that the E-DNA sensor exhibits high selectivity, excellent stability, and remarkable regenerated ability. The human serum analysis indicates that this simple and regenerated strategy holds promising potential in future biosensing applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Combined therapy of Ulmo honey (Eucryphia cordifolia) and ascorbic acid to treat venous ulcers1

    PubMed Central

    Calderon, Mariano del Sol; Figueroa, Carolina Schencke; Arias, Jessica Salvo; Sandoval, Alejandra Hidalgo; Torre, Felipe Ocharan

    2015-01-01

    OBJECTIVE: to assess the clinical effect of topical treatment using Ulmo honey associated with oral ascorbic acid in patients with venous ulcers. METHOD: longitudinal and descriptive quantitative study. During one year, 18 patients were assessed who were clinically diagnosed with venous ulcer in different stages, male and female, adult, with a mean injury time of 13 months. Ulmo honey was topically applied daily. The dressing was applied in accordance with the technical standard for advanced dressings, combined with the daily oral consumptions of 500 mg of ascorbic acid. The monitoring instrument is the assessment table of venous ulcers. RESULTS: full healing was achieved in 100% of the venous ulcers. No signs of complications were observed, such as allergies or infection. CONCLUSION: the proposed treatment showed excellent clinical results for the healing of venous ulcers. The honey demonstrated debriding and non-adherent properties, was easy to apply and remove and was well accepted by the users. The described results generated a research line on chronic wound treatment. PMID:26039296

  2. Determination of perfluorocompounds in popcorn packaging by pressurised liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Martínez-Moral, María Pilar; Tena, María Teresa

    2012-11-15

    The development and characterisation of a method based on reverse-phase ultra-performance liquid chromatography (UPLC) coupled to a quadrupole-time of flight mass spectrometer (Q-TOF-MS) with negative electrospray ionisation (ESI) to determine perfluorinated compounds (PFCs) in packaging is presented in this paper. Analytes were quantitatively recovered from packaging with methanol in only one PLE cycle of 6 min at 100 °C. The UPLC allowed the successful separation of the studied PFCs in less than 4 min. The whole method presented good precision, with RSDs below 8%, LODs from 0.6 to 16 ng g(-1); and excellent recovery values, around 100% in all cases, were achieved. The PLE-UPLC-MS method was applied to the analysis of popcorn packaging for microwave cooking. Besides the most commonly studied PFCs: PFOA and PFOS, the presence of other perfluorocarboxylic acids (PFCAs) in popcorn packaging is evidenced in this work. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Long-term primary culture of mouse mammary tumor cells: production of virus.

    PubMed

    Young, L J; Cardiff, R D; Ashley, R L

    1975-05-01

    Long-term primary cultures of mouse mammary tumor cells proved an excellent source of mouse mammary tumor virus (MMTV). Virus purified from these primary cultures had the same morphologic biochemical, immunologic, and biologic characteristics as MMTV. Quantitation of MMTV-protein equivalents released into the medium was measured by the radioimmunoassay for MMTV. Peak production levels were 20-40 mug MMTV protien equivalents/75-cm-2 flask/24 hours. These cultures produced MMTV for as long as 90 days. MMTV cultivation depended on the initial cell-plating density and hormones. Maximal MMTV release was obtained at a plating density of 1 times 10-6 cells/cm-2 in the presence of insulin and hydrocortisone. Insulin alone gave basal levels of MMTV, and hydrocortisone alone increased MMTV release only three-fold, but insulin and hydrocortisone together effected an eightfold increase in MMTV release. This suggested that hydrocortisone had a primary effect on MMTV release and insulin acted synergistically with hydrocortisone to maximize MMTV release.

  4. Biophotonics determination of 6-benzylaminopurine (6-BAP) plant growth regulator using OFRR biosensor

    NASA Astrophysics Data System (ADS)

    Yang, Gilmo; Kang, Sukwon; Lee, Kangjin; Kim, Giyoung; Son, Jaeryong; Mo, Changyeun

    2010-04-01

    The identification of pesticide and 6-benzylaminopurine (6-BAP) plant growth regulator was carried out using a label-free opto-fluidic ring resonator (OFRR) biosensor. The OFRR sensing platform is a recent advancement in opto-fluidic technology that integrates photonic sensing technology with microfluidics. It features quick detection time, small sample volume, accurate quantitative and kinetic results. The most predominant advantage of the OFRR integrated with microfluidics is that we can potentially realize the multi-channel and portable biosensor that detects numerous analytes simultaneously. Antisera for immunoassay were raised in rabbits against the 6-BAP-BSA conjugate. Using the immunization protocol and unknown cytokinin reacting with same antibody, comparable sensitivity and specificity were obtained. 6-BAP antibody was routinely used for cytokinin analysis. A sensitive and simple OFRR method with a good linear relationship was developed for the determination of 6-BAP. The detection limit was also examined. The biosensor demonstrated excellent reproducibility when periodically exposed to 6-BAP.

  5. Evolution of flowering strategies in Oenothera glazioviana: an integral projection model approach.

    PubMed Central

    Rees, Mark; Rose, Karen E

    2002-01-01

    The timing of reproduction is a key determinant of fitness. Here, we develop parameterized integral projection models of size-related flowering for the monocarpic perennial Oenothera glazioviana and use these to predict the evolutionarily stable strategy (ESS) for flowering. For the most part there is excellent agreement between the model predictions and the results of quantitative field studies. However, the model predicts a much steeper relationship between plant size and the probability of flowering than observed in the field, indicating selection for a 'threshold size' flowering function. Elasticity and sensitivity analysis of population growth rate lambda and net reproductive rate R(0) are used to identify the critical traits that determine fitness and control the ESS for flowering. Using the fitted model we calculate the fitness landscape for invading genotypes and show that this is characterized by a ridge of approximately equal fitness. The implications of these results for the maintenance of genetic variation are discussed. PMID:12137582

  6. Evolution of flowering strategies in Oenothera glazioviana: an integral projection model approach.

    PubMed

    Rees, Mark; Rose, Karen E

    2002-07-22

    The timing of reproduction is a key determinant of fitness. Here, we develop parameterized integral projection models of size-related flowering for the monocarpic perennial Oenothera glazioviana and use these to predict the evolutionarily stable strategy (ESS) for flowering. For the most part there is excellent agreement between the model predictions and the results of quantitative field studies. However, the model predicts a much steeper relationship between plant size and the probability of flowering than observed in the field, indicating selection for a 'threshold size' flowering function. Elasticity and sensitivity analysis of population growth rate lambda and net reproductive rate R(0) are used to identify the critical traits that determine fitness and control the ESS for flowering. Using the fitted model we calculate the fitness landscape for invading genotypes and show that this is characterized by a ridge of approximately equal fitness. The implications of these results for the maintenance of genetic variation are discussed.

  7. Pd/NbOPO₄ multifunctional catalyst for the direct production of liquid alkanes from aldol adducts of furans.

    PubMed

    Xia, Qi-Neng; Cuan, Qian; Liu, Xiao-Hui; Gong, Xue-Qing; Lu, Guan-Zhong; Wang, Yan-Qin

    2014-09-08

    Great efforts have been made to convert renewable biomass into transportation fuels. Herein, we report the novel properties of NbO(x)-based catalysts in the hydrodeoxygenation of furan-derived adducts to liquid alkanes. Excellent activity and stability were observed with almost no decrease in octane yield (>90% throughout) in a 256 h time-on-stream test. Experimental and theoretical studies showed that NbO(x) species play the key role in C-O bond cleavage. As a multifunctional catalyst, Pd/NbOPO4 plays three roles in the conversion of aldol adducts into alkanes: 1) The noble metal (in this case Pd) is the active center for hydrogenation; 2) NbO(x) species help to cleave the C-O bond, especially of the tetrahydrofuran ring; and 3) a niobium-based solid acid catalyzes the dehydration, thus enabling the quantitative conversion of furan-derived adducts into alkanes under mild conditions. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Pulmonary hypoxic vasoconstriction: how strong? How fast?

    NASA Technical Reports Server (NTRS)

    Sheehan, D. W.; Klocke, R. A.; Farhi, L. E.

    1992-01-01

    We have developed a minimally invasive technique for studying regional blood flow in conscious sheep, bypassing the complications of open-chest surgery, flow probes and tracer infusion. We quantitate regional perfusion continuously on the basis of regional clearance of methane (methane is produced in the sheep rumen, enters the circulation and is eliminated nearly completely (greater than 95%) in the lung). Tracheal intubation with a dual-lumen catheter isolates the gas exchange of the right apical lobe (RAL; less than 15% of the lung) from that of the remainder of the lung, which serves as a control (CL). We measure RAL and CL methane elimination by entraining expirates in constant flows, sampled continuously for methane. Results obtained with this technique and from regional oxygen uptake are in excellent agreement. We have found that hypoxic vasoconstriction is far more potent and stable during eucapnic hypoxia than during hypocapnic hypoxia. The time course of the vasoconstriction suggests that many of the data in the literature may have been obtained prior to steady state.

  9. Detection of laryngeal function using speech and electroglottographic data.

    PubMed

    Childers, D G; Bae, K S

    1992-01-01

    The purpose of this research was to develop quantitative measures for the assessment of laryngeal function using speech and electroglottographic (EGG) data. We developed two procedures for the detection of laryngeal pathology: 1) a spectral distortion measure using pitch synchronous and asynchronous methods with linear predictive coding (LPC) vectors and vector quantization (VQ) and 2) analysis of the EGG signal using time interval and amplitude difference measures. The VQ procedure was conjectured to offer the possibility of circumventing the need to estimate the glottal volume velocity wave-form by inverse filtering techniques. The EGG procedure was to evaluate data that was "nearly" a direct measure of vocal fold vibratory motion and thus was conjectured to offer the potential for providing an excellent assessment of laryngeal function. A threshold based procedure gave 75.9 and 69.0% probability of pathological detection using procedures 1) and 2), respectively, for 29 patients with pathological voices and 52 normal subjects. The false alarm probability was 9.6% for the normal subjects.

  10. A superconducting tunnel junction receiver for millimeter-wave astronomy

    NASA Technical Reports Server (NTRS)

    Pan, S. K.; Kerr, A. R.

    1986-01-01

    The development and construction of an ultralow noise heterodyne receiver for millimeter wave astronomy is described along with its use for 115.3 GHz Co line observations. The receiver uses a Superconductor-Insulator-Superconductor (SIS) quasiparticle tunnel junction mixer to convert the millimeter wave signal to a microwave intermediate frequency. Experiments aimed at quantitative verification of J. R. Tucker's quantum mixer theory are studied, to see whether it could be used as the basis for the design of a practical receiver. The experimental results were in excellent agreement with the theory, assuming the three frequency approximation. Infinite available gain and negative output resistance were observed for the first time, nonclassical effects which are not seen in conventional diode mixers. Using Tucker's theory, an SIS receiver was then designed and constructed. At 115 GHz, the single sideband receiver noise temperature is 83K, the lowest ever reported in this frequency range. A CO survey toward Cygnus-X region, using this SIS receiver on the Columbia-GISS 4 ft. telescope, is also described.

  11. Numerical formulation for the prediction of solid/liquid change of a binary alloy

    NASA Technical Reports Server (NTRS)

    Schneider, G. E.; Tiwari, S. N.

    1990-01-01

    A computational model is presented for the prediction of solid/liquid phase change energy transport including the influence of free convection fluid flow in the liquid phase region. The computational model considers the velocity components of all non-liquid phase change material control volumes to be zero but fully solves the coupled mass-momentum problem within the liquid region. The thermal energy model includes the entire domain and uses an enthalpy like model and a recently developed method for handling the phase change interface nonlinearity. Convergence studies are performed and comparisons made with experimental data for two different problem specifications. The convergence studies indicate that grid independence was achieved and the comparison with experimental data indicates excellent quantitative prediction of the melt fraction evolution. Qualitative data is also provided in the form of velocity vector diagrams and isotherm plots for selected times in the evolution of both problems. The computational costs incurred are quite low by comparison with previous efforts on solving these problems.

  12. [A Study on Quantitative Evaluation of Damage in Conservation of Ceramics from Huaguangjiao I Shipwreck with ICP-AES].

    PubMed

    Li, Wen-jing; Chen, Yue; Li, Nai-sheng; Li, Bin; Luo, Wu-gan

    2015-03-01

    ICP-AES was used to determine the elemental composition of solutions in different conservation steps for understanding the impact of cleaning agents on ceramics from Huaguangjiao I shipwreck. The results showed that high content in solution of Al, Fe, Mg ions, which can be indexes to reflect the damage in conservation of ceramics. According to these indexes, we discovered that agents of strong cleaning ability bring more damage to ceramic samples. Meanwhile, the state of preservation of the ceramics was closely related to the damage in conservation. Ceramics in an excellent state of preservation endure less damage than that in bad state. We also found that each cleaning agent cause certain degree of damage on porcelains, even neutral reagent, like deionized water. Moreover, moderate cleaning reagent, when using a long time, bring the same degree of damage as the strong acid. Therefore, in actual protection procedure, for conservation ceramics safe and effective, damage of each cleaning agents and cumulative damage should be considered.

  13. The transcriptomes of novel marmoset monkey embryonic stem cell lines reflect distinct genomic features

    PubMed Central

    Debowski, Katharina; Drummer, Charis; Lentes, Jana; Cors, Maren; Dressel, Ralf; Lingner, Thomas; Salinas-Riester, Gabriela; Fuchs, Sigrid; Sasaki, Erika; Behr, Rüdiger

    2016-01-01

    Embryonic stem cells (ESCs) are useful for the study of embryonic development. However, since research on naturally conceived human embryos is limited, non-human primate (NHP) embryos and NHP ESCs represent an excellent alternative to the corresponding human entities. Though, ESC lines derived from naturally conceived NHP embryos are still very rare. Here, we report the generation and characterization of four novel ESC lines derived from natural preimplantation embryos of the common marmoset monkey (Callithrix jacchus). For the first time we document derivation of NHP ESCs derived from morula stages. We show that quantitative chromosome-wise transcriptome analyses precisely reflect trisomies present in both morula-derived ESC lines. We also demonstrate that the female ESC lines exhibit different states of X-inactivation which is impressively reflected by the abundance of the lncRNA X inactive-specific transcript (XIST). The novel marmoset ESC lines will promote basic primate embryo and ESC studies as well as preclinical testing of ESC-based regenerative approaches in NHP. PMID:27385131

  14. The transcriptomes of novel marmoset monkey embryonic stem cell lines reflect distinct genomic features.

    PubMed

    Debowski, Katharina; Drummer, Charis; Lentes, Jana; Cors, Maren; Dressel, Ralf; Lingner, Thomas; Salinas-Riester, Gabriela; Fuchs, Sigrid; Sasaki, Erika; Behr, Rüdiger

    2016-07-07

    Embryonic stem cells (ESCs) are useful for the study of embryonic development. However, since research on naturally conceived human embryos is limited, non-human primate (NHP) embryos and NHP ESCs represent an excellent alternative to the corresponding human entities. Though, ESC lines derived from naturally conceived NHP embryos are still very rare. Here, we report the generation and characterization of four novel ESC lines derived from natural preimplantation embryos of the common marmoset monkey (Callithrix jacchus). For the first time we document derivation of NHP ESCs derived from morula stages. We show that quantitative chromosome-wise transcriptome analyses precisely reflect trisomies present in both morula-derived ESC lines. We also demonstrate that the female ESC lines exhibit different states of X-inactivation which is impressively reflected by the abundance of the lncRNA X inactive-specific transcript (XIST). The novel marmoset ESC lines will promote basic primate embryo and ESC studies as well as preclinical testing of ESC-based regenerative approaches in NHP.

  15. Quality control of test iodine in urine by spectrophotometry UV-Vis

    NASA Astrophysics Data System (ADS)

    Huda, Thorikul; Nafisah, Durotun; Kumorowulan, Suryati; Lestari, Sri

    2017-12-01

    A quality control of iodine test in with UV-Vis spectrophotometry has been done. The purpose of this research is to find out whether the test results of samples conducted by Clinical Office of Research and Development Of GAKI (BP2GAKI) laboratory are still controlled, feasible and reliable, and still consistent over time, as indicated by the control chart. Quality control parameters are linearity, precision, accuracy, limit of detection, and limit of quantification. Based on the quality control that has been done, obtained linearity (r)= -0.9974, the detection limit and the limit of quantitation are respectively 2.26 µg/L and 7.54 µg/L, while the accuracy is calculated by %recovery and precision with value % RSD are 97.4161% and 1.7136% respectively. The quality control of iodine test in urine using the control chart shows excellent or stable results for 30 days and no variation of the results is very different for each day.

  16. Extinction in neutrally stable stochastic Lotka-Volterra models

    NASA Astrophysics Data System (ADS)

    Dobrinevski, Alexander; Frey, Erwin

    2012-05-01

    Populations of competing biological species exhibit a fascinating interplay between the nonlinear dynamics of evolutionary selection forces and random fluctuations arising from the stochastic nature of the interactions. The processes leading to extinction of species, whose understanding is a key component in the study of evolution and biodiversity, are influenced by both of these factors. Here, we investigate a class of stochastic population dynamics models based on generalized Lotka-Volterra systems. In the case of neutral stability of the underlying deterministic model, the impact of intrinsic noise on the survival of species is dramatic: It destroys coexistence of interacting species on a time scale proportional to the population size. We introduce a new method based on stochastic averaging which allows one to understand this extinction process quantitatively by reduction to a lower-dimensional effective dynamics. This is performed analytically for two highly symmetrical models and can be generalized numerically to more complex situations. The extinction probability distributions and other quantities of interest we obtain show excellent agreement with simulations.

  17. Extinction in neutrally stable stochastic Lotka-Volterra models.

    PubMed

    Dobrinevski, Alexander; Frey, Erwin

    2012-05-01

    Populations of competing biological species exhibit a fascinating interplay between the nonlinear dynamics of evolutionary selection forces and random fluctuations arising from the stochastic nature of the interactions. The processes leading to extinction of species, whose understanding is a key component in the study of evolution and biodiversity, are influenced by both of these factors. Here, we investigate a class of stochastic population dynamics models based on generalized Lotka-Volterra systems. In the case of neutral stability of the underlying deterministic model, the impact of intrinsic noise on the survival of species is dramatic: It destroys coexistence of interacting species on a time scale proportional to the population size. We introduce a new method based on stochastic averaging which allows one to understand this extinction process quantitatively by reduction to a lower-dimensional effective dynamics. This is performed analytically for two highly symmetrical models and can be generalized numerically to more complex situations. The extinction probability distributions and other quantities of interest we obtain show excellent agreement with simulations.

  18. Non-aqueous capillary electrophoretic separation of cholesterol and 25-hydroxycholesterol after derivatization with Girard P reagent.

    PubMed

    Gregus, Michal; Roberg-Larsen, Hanne; Lundanes, Elsa; Foret, Frantisek; Kuban, Petr; Wilson, Steven Ray

    2017-10-01

    Capillary electrophoresis (CE) can provide high separation efficiency with very simple instrumentation, but has yet to be explored regarding oxysterols/cholesterol. Cholesterol and 25-hydroxycholesterol (both are 4-ene-3-ketosteroids) were quantitatively transformed into hydrazones using Girard P reagent after enzymatic oxidation by cholesterol oxidase. Separation was achieved using non-aqueous capillary electrophoresis with UV detection at 280nm; the "charge-tagging" Girard P reagent ensured both charge and chromophore (which are requirements for CE-UV). Excess reagent was also separated from the two analytes, eliminating the need for removal prior to the analysis. The compounds were separated in less than 5min with excellent separation efficiency, using separation electrolytes fully compatible with mass spectrometry. The CE-UV method was used to optimize steps for charge-tagging, revealing that the procedure is affected by the analyte/reagent ratio and reaction time, but also the analyte structure. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Analysis of Trace Quaternary Ammonium Compounds (QACs) in Vegetables Using Ultrasonic-Assisted Extraction and Gas Chromatography-Mass Spectrometry.

    PubMed

    Xiang, Lei; Wang, Xiong-Ke; Li, Yan-Wen; Huang, Xian-Pei; Wu, Xiao-Lian; Zhao, Hai-Ming; Li, Hui; Cai, Quan-Ying; Mo, Ce-Hui

    2015-08-05

    A reliable, sensitive, and cost-effective method was developed for determining three quaternary ammonium compounds (QACs) including dodecyltrimethylammonium chloride, cetyltrimethylammonium chloride, and didodecyldimethylammonium chloride in various vegetables using ultrasonic-assisted extraction and gas chromatography-mass spectrometry. The variety and acidity of extraction solvents, extraction times, and cleanup efficiency of sorbents were estimated to obtain an optimized procedure for extraction of the QACs in nine vegetable matrices. Excellent linearities (R(2) > 0.992) were obtained for the analytes in the nine matrices. The limits of detection and quantitation were 0.7-6.0 and 2.3-20.0 μg/kg (dry weight, dw) in various matrices, respectively. The recoveries in the nine matrices ranged from 70.5% to 108.0% with relative standard deviations below 18.0%. The developed method was applied to determine the QACs in 27 vegetable samples collected from Guangzhou in southern China, showing very high detection frequency with a concentration of 23-180 μg/kg (dw).

  20. Computer-assisted engineering of the synthetic pathway for biodegradation of a toxic persistent pollutant.

    PubMed

    Kurumbang, Nagendra Prasad; Dvorak, Pavel; Bendl, Jaroslav; Brezovsky, Jan; Prokop, Zbynek; Damborsky, Jiri

    2014-03-21

    Anthropogenic halogenated compounds were unknown to nature until the industrial revolution, and microorganisms have not had sufficient time to evolve enzymes for their degradation. The lack of efficient enzymes and natural pathways can be addressed through a combination of protein and metabolic engineering. We have assembled a synthetic route for conversion of the highly toxic and recalcitrant 1,2,3-trichloropropane to glycerol in Escherichia coli, and used it for a systematic study of pathway bottlenecks. Optimal ratios of enzymes for the maximal production of glycerol, and minimal toxicity of metabolites were predicted using a mathematical model. The strains containing the expected optimal ratios of enzymes were constructed and characterized for their viability and degradation efficiency. Excellent agreement between predicted and experimental data was observed. The validated model was used to quantitatively describe the kinetic limitations of currently available enzyme variants and predict improvements required for further pathway optimization. This highlights the potential of forward engineering of microorganisms for the degradation of toxic anthropogenic compounds.

  1. The Novel Immunobiosensors for Detection of Escherichia coli O157:H7 Using Electrochemical Impedance Spectroscopy.

    PubMed

    Zhang, Deng; Chen, Songyue; Qin, Lifeng; Li, Rong; Wang, Ping; Li, Yanbin

    2005-01-01

    Immunobiosensors were developed for detection of Escherichia coli O157:H7 based on the surface immobilization of monoclone antibodies onto indium tin oxide (ITO) electrodes. The immobilization of antibodies onto ITO chips was carried out by silanization. The effects of epoxysilane monolayer, the antibody layer on the electrochemical properties of the electrode, and the combined target bacteria were analyzed through cyclic voltammetry and electrochemical impedance spectroscopy. By using Randles model as the equivalent circuit, the concentration of the target bacteria can be quantitatively analyzed in terms of the change of electron transfer resistance. The biosensor could detect the target bacteria with a detection limit of 4×103CFU/mL. A linear response was found between 4×103- 4×106CFU/mL. This biosensor was characterized with high sensitivity, excellent selectivity, short detection time and easy operation It has a promising application in clinical laboratory diagnoses, environmental detection and food safety.

  2. The fluid trampoline: droplets bouncing on a soap film

    NASA Astrophysics Data System (ADS)

    Bush, John; Gilet, Tristan

    2008-11-01

    We present the results of a combined experimental and theoretical investigation of droplets falling onto a horizontal soap film. Both static and vertically vibrated soap films are considered. A quasi-static description of the soap film shape yields a force-displacement relation that provides excellent agreement with experiment, and allows us to model the film as a nonlinear spring. This approach yields an accurate criterion for the transition between droplet bouncing and crossing on the static film; moreover, it allows us to rationalize the observed constancy of the contact time and scaling for the coefficient of restitution in the bouncing states. On the vibrating film, a variety of bouncing behaviours were observed, including simple and complex periodic states, multiperiodicity and chaos. A simple theoretical model is developed that captures the essential physics of the bouncing process, reproducing all observed bouncing states. Quantitative agreement between model and experiment is deduced for simple periodic modes, and qualitative agreement for more complex periodic and chaotic bouncing states.

  3. Ultrafast photoinduced charge separation in metal-semiconductor nanohybrids.

    PubMed

    Mongin, Denis; Shaviv, Ehud; Maioli, Paolo; Crut, Aurélien; Banin, Uri; Del Fatti, Natalia; Vallée, Fabrice

    2012-08-28

    Hybrid nano-objects formed by two or more disparate materials are among the most promising and versatile nanosystems. A key parameter in their properties is interaction between their components. In this context we have investigated ultrafast charge separation in semiconductor-metal nanohybrids using a model system of gold-tipped CdS nanorods in a matchstick architecture. Experiments are performed using an optical time-resolved pump-probe technique, exciting either the semiconductor or the metal component of the particles, and probing the light-induced change of their optical response. Electron-hole pairs photoexcited in the semiconductor part of the nanohybrids are shown to undergo rapid charge separation with the electron transferred to the metal part on a sub-20 fs time scale. This ultrafast gold charging leads to a transient red-shift and broadening of the metal surface plasmon resonance, in agreement with results for free clusters but in contrast to observation for static charging of gold nanoparticles in liquid environments. Quantitative comparison with a theoretical model is in excellent agreement with the experimental results, confirming photoexcitation of one electron-hole pair per nanohybrid followed by ultrafast charge separation. The results also point to the utilization of such metal-semiconductor nanohybrids in light-harvesting applications and in photocatalysis.

  4. Quantitative measurement of regional blood flow with gadolinium diethylenetriaminepentaacetate bolus track NMR imaging in cerebral infarcts in rats: validation with the iodo[14C]antipyrine technique.

    PubMed Central

    Wittlich, F; Kohno, K; Mies, G; Norris, D G; Hoehn-Berlage, M

    1995-01-01

    NMR bolus track measurements were correlated with autoradiographically determined regional cerebral blood flow (rCBF). The NMR method is based on bolus infusion of the contrast agent gadolinium diethylenetriaminepentaacetate and high-speed T*2-sensitive NMR imaging. The first pass of the contrast agent through the image plane causes a transient decrease of the signal intensity. This time course of the signal intensity is transformed into relative concentrations of the contrast agent in each pixel. The mean transit time and relative blood flow and volume are calculated from such indicator dilution curves. We investigated whether this NMR technique correctly expresses the relative rCBF. The relative blood flow data, calculated from NMR bolus track experiments, and the absolute values of iodo[14C]antipyrine autoradiography were compared. A linear relationship was observed, indicating the proportionality of the transient NMR signal change with CBF. Excellent interindividual reproducibility of calibration constants is observed (r = 0.963). For a given NMR protocol, bolus track measurements calibrated with autoradiography after the experiment allow determination of absolute values for rCBF and regional blood volume. Images Fig. 2 Fig. 3 PMID:7892189

  5. Direct Measurements of Half-Cycle Reaction Heats during Atomic Layer Deposition by Calorimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lownsbury, James M.; Gladden, James A.; Campbell, Charles T.

    We introduce a new high-temperature adsorption calorimeter that approaches the ideal limit of a heat detector whereby the signal at any time is proportional to the heat power being delivered to the sample and prove its sensitivity for measuring pulse-to-pulse heats of half-reactions during atomic layer deposition (ALD) at 400 K. The heat dynamics of amorphous Al2O3 growth via sequential self-limiting surface reaction of trimethylaluminum (TMA) and H2O is clearly resolved. Calibration enables quantitation of the exothermic TMA and H2O half-reactions with high precision, -343 kJ/mol TMA and -251 kJ/mol H2O, respectively. A time resolution better than 1 ms ismore » demonstrated, allowing for the deconvolution of at least two distinct surface reactions during TMA microdosing. It is further demonstrated that this method can provide the heat of reaction versus extent of reaction during each precursors half-reaction, thus providing even richer mechanistic information on the surface processes involved. The broad applicability of this novel calorimeter is demonstrated through excellent signal-to-noise ratios of less exothermic ALD half-reactions to produce TiO2 and MnO.« less

  6. Zircon age-temperature-compositional spectra in plutonic rocks

    DOE PAGES

    Samperton, Kyle M.; Bell, Elizabeth A.; Barboni, Mélanie; ...

    2017-08-23

    We present that geochronology can resolve dispersed zircon dates in plutonic rocks when magma cooling time scales exceed the temporal precision of individual U-Pb analyses; such age heterogeneity may indicate protracted crystallization between the temperatures of zircon saturation (T sat) and rock solidification (T solid). Diffusive growth models predict asymmetric distributions of zircon dates and crystallization temperatures in a cooling magma, with volumetrically abundant old, hot crystallization at T sat decreasing continuously to volumetrically minor young, cold crystallization at T solid. We present integrated geochronological and geochemical data from Bergell Intrusion tonalites (Central Alps, Europe) that document zircon compositional changemore » over hundreds of thousands of years at the hand-sample scale, indicating melt compositional evolution during solidification. Ti-in-zircon thermometry, crystallization simulation using MELTS software, and U-Pb dates produce zircon mass-temperature-time distributions that are in excellent agreement with zircon growth models. In conclusion, these findings provide the first quantitative validation of longstanding expectations from zircon saturation theory by direct geochronological investigation, underscoring zircon’s capacity to quantify supersolidus cooling rates in magmas and resolve dynamic differentiation histories in the plutonic rock record.« less

  7. Photoinduced smart, self-healing polymer sealant for photovoltaics.

    PubMed

    Banerjee, Sanjib; Tripathy, Ranjan; Cozzens, David; Nagy, Tibor; Keki, Sandor; Zsuga, Miklos; Faust, Rudolf

    2015-01-28

    Polyisobutylene (PIB)-based polymer networks potentially useful as smart coatings for photovoltaic devices have been developed. Low molecular weight coumarin functional triarm star PIB was synthesized via a single step SN2 reaction of bromoallyl functional triarm star PIB with 4-methylumbelliferone or umbelliferone in the presence of sodium hydride. Quantitative end functionality was confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. UVA (λmax = 365 nm) induced reversible photodimerization of the coumarin moieties resulted in cross-linked elastomeric films exhibiting self-healing behavior. The extent of photodimerization/photoscission was monitored by UV-vis spectroscopy. The low oxygen (1.9 × 10(-16) mol m m(-2) s(-1) Pa(-1)) and moisture (46 × 10(-16) mol m m(-2) s(-1) Pa(-1)) permeability of the cross-linked polymer films suggest excellent barrier properties of the cross-linked polymer films. The self-healing process was studied by atomic force microscopy (AFM). For this, mechanical cuts were introduced in the cross-linked PIB films through micromachining with an AFM tip and the rate of healing induced by UV, sunlight, or both was followed by taking AFM images of the film at different time intervals during the repair process.

  8. Human exposure assessment: a graduate level course

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lioy, P.J.

    1991-07-01

    The course has been offered three times. The content and the approach to each lecture has evolved after each time it was given. This is not unexpected since the field has been undergoing major transformations, and new approaches to measurement and modeling are being applied to current problems. The most recent student evaluation, 1990, indicates a difficulty rating of just right' (70%) to difficult' (30%). Most felt the course stimulated their interest in the topic (72%) and the examinations were learning experiences as well as a grading exercise. The major need for the discipline is an adequate text book. Themore » GRAPE program has excellent potential as an educational tool, but it needs to make more interactions and allow introduction of activities and data. The major strengths of the course are the problems provided to the students for homework. These give the student quantitative perspective on the concepts, range in values, variables, and uncertainties necessary to complete an assessment. In addition, the development of the mathematical and conceptional continuum for placing exposure assessment in the context of toxicology, environmental science, epidemiology, and clinical intervention provides a basic framework for the discipline.« less

  9. High-resolution detection of Brownian motion for quantitative optical tweezers experiments.

    PubMed

    Grimm, Matthias; Franosch, Thomas; Jeney, Sylvia

    2012-08-01

    We have developed an in situ method to calibrate optical tweezers experiments and simultaneously measure the size of the trapped particle or the viscosity of the surrounding fluid. The positional fluctuations of the trapped particle are recorded with a high-bandwidth photodetector. We compute the mean-square displacement, as well as the velocity autocorrelation function of the sphere, and compare it to the theory of Brownian motion including hydrodynamic memory effects. A careful measurement and analysis of the time scales characterizing the dynamics of the harmonically bound sphere fluctuating in a viscous medium directly yields all relevant parameters. Finally, we test the method for different optical trap strengths, with different bead sizes and in different fluids, and we find excellent agreement with the values provided by the manufacturers. The proposed approach overcomes the most commonly encountered limitations in precision when analyzing the power spectrum of position fluctuations in the region around the corner frequency. These low frequencies are usually prone to errors due to drift, limitations in the detection, and trap linearity as well as short acquisition times resulting in poor statistics. Furthermore, the strategy can be generalized to Brownian motion in more complex environments, provided the adequate theories are available.

  10. In situ loading of well-dispersed silver nanoparticles on nanocrystalline magnesium oxide for real-time monitoring of catalytic reactions by surface enhanced Raman spectroscopy.

    PubMed

    Zhang, Kaige; Li, Gongke; Hu, Yuling

    2015-10-28

    The surface-enhanced Raman spectroscopy (SERS) technique is of great importance for insight into the transient reaction intermediates and mechanistic pathways involved in heterogeneously catalyzed chemical reactions under actual reaction conditions, especially in water. Herein, we demonstrate a facile method for in situ synthesis of nanocrystalline magnesium oxide-Ag(0) (nano MgO-Ag(0)) hybrid nanomaterials with dispersed Ag nanoparticles (Ag NPs) on the surface of nanocrystalline magnesium oxide (nano MgO) via Sn(2+) linkage and reduction. As a benefit from the synergy effect of nano MgO and Ag NPs, the nano MgO-Ag(0) exhibited both excellent SERS and catalytic activities for the reduction of 4-nitrothiophenol in the presence of NaBH4. The nano MgO-Ag(0) was used for real-time monitoring of the catalytic reaction process of 4-nitrothiophenol to 4-aminothiophenol in an aqueous medium by observing the SERS signals of the reactant, intermediate and final products. The intrinsic reaction kinetics and reaction mechanism of this reaction were also investigated. This SERS-based synergy technique provides a novel approach for quantitative in situ monitoring of catalytic chemical reaction processes.

  11. Zircon age-temperature-compositional spectra in plutonic rocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Samperton, Kyle M.; Bell, Elizabeth A.; Barboni, Mélanie

    We present that geochronology can resolve dispersed zircon dates in plutonic rocks when magma cooling time scales exceed the temporal precision of individual U-Pb analyses; such age heterogeneity may indicate protracted crystallization between the temperatures of zircon saturation (T sat) and rock solidification (T solid). Diffusive growth models predict asymmetric distributions of zircon dates and crystallization temperatures in a cooling magma, with volumetrically abundant old, hot crystallization at T sat decreasing continuously to volumetrically minor young, cold crystallization at T solid. We present integrated geochronological and geochemical data from Bergell Intrusion tonalites (Central Alps, Europe) that document zircon compositional changemore » over hundreds of thousands of years at the hand-sample scale, indicating melt compositional evolution during solidification. Ti-in-zircon thermometry, crystallization simulation using MELTS software, and U-Pb dates produce zircon mass-temperature-time distributions that are in excellent agreement with zircon growth models. In conclusion, these findings provide the first quantitative validation of longstanding expectations from zircon saturation theory by direct geochronological investigation, underscoring zircon’s capacity to quantify supersolidus cooling rates in magmas and resolve dynamic differentiation histories in the plutonic rock record.« less

  12. Direct Measurements of Half-Cycle Reaction Heats during Atomic Layer Deposition by Calorimetry

    DOE PAGES

    Lownsbury, James M.; Gladden, James A.; Campbell, Charles T.; ...

    2017-10-05

    We introduce a new high-temperature adsorption calorimeter that approaches the ideal limit of a heat detector whereby the signal at any time is proportional to the heat power being delivered to the sample and prove its sensitivity for measuring pulse-to-pulse heats of half-reactions during atomic layer deposition (ALD) at 400 K. The heat dynamics of amorphous Al2O3 growth via sequential self-limiting surface reaction of trimethylaluminum (TMA) and H2O is clearly resolved. Calibration enables quantitation of the exothermic TMA and H2O half-reactions with high precision, -343 kJ/mol TMA and -251 kJ/mol H2O, respectively. A time resolution better than 1 ms ismore » demonstrated, allowing for the deconvolution of at least two distinct surface reactions during TMA microdosing. It is further demonstrated that this method can provide the heat of reaction versus extent of reaction during each precursors half-reaction, thus providing even richer mechanistic information on the surface processes involved. The broad applicability of this novel calorimeter is demonstrated through excellent signal-to-noise ratios of less exothermic ALD half-reactions to produce TiO2 and MnO.« less

  13. Preparing data for analysis using microsoft Excel.

    PubMed

    Elliott, Alan C; Hynan, Linda S; Reisch, Joan S; Smith, Janet P

    2006-09-01

    A critical component essential to good research is the accurate and efficient collection and preparation of data for analysis. Most medical researchers have little or no training in data management, often causing not only excessive time spent cleaning data but also a risk that the data set contains collection or recording errors. The implementation of simple guidelines based on techniques used by professional data management teams will save researchers time and money and result in a data set better suited to answer research questions. Because Microsoft Excel is often used by researchers to collect data, specific techniques that can be implemented in Excel are presented.

  14. Data acquisition and real-time control using spreadsheets: interfacing Excel with external hardware.

    PubMed

    Aliane, Nourdine

    2010-07-01

    Spreadsheets have become a popular computational tool and a powerful platform for performing engineering calculations. Moreover, spreadsheets include a macro language, which permits the inclusion of standard computer code in worksheets, and thereby enable developers to greatly extend spreadsheets' capabilities by designing specific add-ins. This paper describes how to use Excel spreadsheets in conjunction to Visual Basic for Application programming language to perform data acquisition and real-time control. Afterwards, the paper presents two Excel applications with interactive user interfaces developed for laboratory demonstrations and experiments in an introductory course in control. 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Changing climate in a pre-impact world: a multi-proxy paleotemperature reconstruction across the last million years of the Cretaceous

    NASA Astrophysics Data System (ADS)

    Woelders, L.; Vellekoop, J.; Reichart, G. J.; de Nooijer, L. J.; Sluijs, A.; Peterse, F.; Claeys, P. F.; Speijer, R. P.

    2015-12-01

    Climate instability during the last million years of the Cretaceous (67-66 Ma) is still poorly documented and not well understood. One of the reasons for this is that in deep time, different proxies are likely to yield different temperatures. This is because the application of calibrations based on present day temperature proxy relationships is affected by source organism evolution, differences in ocean chemistry and non-analogue processes. Only by combining temperature estimates derived from different, independent proxies, the problems with individual proxies can be cancelled out. A quantitative, multi-proxy temperature record from the latest Cretaceous therefore may provide a better insight in climate changes across this time interval. For such a multi-proxy research, sediments are required that yield both well-preserved foraminiferal calcite as well as organic biomarkers. Very few sites are known to provide such sedimentary records, but ODP Leg 174AX Site Bass River (New Jersey Shelf) has proven to be an excellent archive for paleotemperature reconstructions for the Cretaceous and Paleogene. We here present a multi-proxy, quantitative paleotemperature reconstruction of the last million years of the Cretaceous of the Bass River core. Benthic and planktic foraminiferal Mg/Ca and δ18O were determined, as well as the organic geochemical sea surface temperature proxy TEX86. This resulted in a unique coupled surface and bottom water temperature record of the latest Cretaceous. Our data suggest a ~2-6 ˚C bottom water warming and a ~4-6 ˚C surface water warming approximately 300 kyr before the Cretaceous-Paleogene boundary, followed by a cooling trend across the boundary. This warming event appears to coincide with the main phase of the Deccan Traps eruptions and therefore probably represents a global event.

  16. Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnstone, Chris; Bazalova-Carter, Magdalena

    Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional datamore » sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.« less

  17. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics.

    PubMed

    Georgsson, Mattias; Staggers, Nancy

    2016-01-01

    Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients' perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients' task performance, satisfaction, and the relationship of these measures to user characteristics. We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients' experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  18. Quantifying usability: an evaluation of a diabetes mHealth system on effectiveness, efficiency, and satisfaction metrics with associated user characteristics

    PubMed Central

    Staggers, Nancy

    2016-01-01

    Objective Mobile health (mHealth) systems are becoming more common for chronic disease management, but usability studies are still needed on patients’ perspectives and mHealth interaction performance. This deficiency is addressed by our quantitative usability study of a mHealth diabetes system evaluating patients’ task performance, satisfaction, and the relationship of these measures to user characteristics. Materials and Methods We used metrics in the International Organization for Standardization (ISO) 9241-11 standard. After standardized training, 10 patients performed representative tasks and were assessed on individual task success, errors, efficiency (time on task), satisfaction (System Usability Scale [SUS]) and user characteristics. Results Tasks of exporting and correcting values proved the most difficult, had the most errors, the lowest task success rates, and consumed the longest times on task. The average SUS satisfaction score was 80.5, indicating good but not excellent system usability. Data trends showed males were more successful in task completion, and younger participants had higher performance scores. Educational level did not influence performance, but a more recent diabetes diagnosis did. Patients with more experience in information technology (IT) also had higher performance rates. Discussion Difficult task performance indicated areas for redesign. Our methods can assist others in identifying areas in need of improvement. Data about user background and IT skills also showed how user characteristics influence performance and can provide future considerations for targeted mHealth designs. Conclusion Using the ISO 9241-11 usability standard, the SUS instrument for satisfaction and measuring user characteristics provided objective measures of patients’ experienced usability. These could serve as an exemplar for standardized, quantitative methods for usability studies on mHealth systems. PMID:26377990

  19. Simplified and Efficient Quantification of Low-abundance Proteins at Very High Multiplex via Targeted Mass Spectrometry*

    PubMed Central

    Burgess, Michael W.; Keshishian, Hasmik; Mani, D. R.; Gillette, Michael A.; Carr, Steven A.

    2014-01-01

    Liquid chromatography–multiple reaction monitoring mass spectrometry (LC-MRM-MS) of plasma that has been depleted of abundant proteins and fractionated at the peptide level into six to eight fractions is a proven method for quantifying proteins present at low nanogram-per-milliliter levels. A drawback of fraction-MRM is the increased analysis time due to the generation of multiple fractions per biological sample. We now report that the use of heated, long, fused silica columns (>30 cm) packed with 1.9 μm of packing material can reduce or eliminate the need for fractionation prior to LC-MRM-MS without a significant loss of sensitivity or precision relative to fraction-MRM. We empirically determined the optimal column length, temperature, gradient duration, and sample load for such assays and used these conditions to study detection sensitivity and assay precision. In addition to increased peak capacity, longer columns packed with smaller beads tolerated a 4- to 6-fold increase in analyte load without a loss of robustness or reproducibility. The longer columns also provided a 4-fold improvement in median limit-of-quantitation values with increased assay precision relative to the standard 12 cm columns packed with 3 μm material. Overall, the optimized chromatography provided an approximately 3-fold increase in analysis throughput with excellent robustness and less than a 2-fold reduction in quantitative sensitivity relative to fraction-MRM. The value of the system for increased multiplexing was demonstrated by the ability to configure an 800-plex MRM-MS assay, run in a single analysis, comprising 2400 transitions with retention time scheduling to monitor 400 unlabeled and heavy labeled peptide pairs. PMID:24522978

  20. Solving the Vlasov equation in two spatial dimensions with the Schrödinger method

    NASA Astrophysics Data System (ADS)

    Kopp, Michael; Vattis, Kyriakos; Skordis, Constantinos

    2017-12-01

    We demonstrate that the Vlasov equation describing collisionless self-gravitating matter may be solved with the so-called Schrödinger method (ScM). With the ScM, one solves the Schrödinger-Poisson system of equations for a complex wave function in d dimensions, rather than the Vlasov equation for a 2 d -dimensional phase space density. The ScM also allows calculating the d -dimensional cumulants directly through quasilocal manipulations of the wave function, avoiding the complexity of 2 d -dimensional phase space. We perform for the first time a quantitative comparison of the ScM and a conventional Vlasov solver in d =2 dimensions. Our numerical tests were carried out using two types of cold cosmological initial conditions: the classic collapse of a sine wave and those of a Gaussian random field as commonly used in cosmological cold dark matter N-body simulations. We compare the first three cumulants, that is, the density, velocity and velocity dispersion, to those obtained by solving the Vlasov equation using the publicly available code ColDICE. We find excellent qualitative and quantitative agreement between these codes, demonstrating the feasibility and advantages of the ScM as an alternative to N-body simulations. We discuss, the emergence of effective vorticity in the ScM through the winding number around the points where the wave function vanishes. As an application we evaluate the background pressure induced by the non-linearity of large scale structure formation, thereby estimating the magnitude of cosmological backreaction. We find that it is negligibly small and has time dependence and magnitude compatible with expectations from the effective field theory of large scale structure.

  1. Quantitative detection of RO2 radicals and other products from cyclohexene ozonolysis with ammonium-CI3-TOF and acetate-CI-API-TOF

    NASA Astrophysics Data System (ADS)

    Hansel, A.; Scholz, W.; Mentler, B.; Fischer, L.; Berndt, T.

    2017-12-01

    The performance of the novel ammonium-CI3-TOF utilizing NH4+ adduct ion chemistry to measure quantitatively first generation oxidized product molecules (OMs) as well as highly oxidized organic molecules (HOMs) was investigated for the first time. The gas-phase ozonolysis of cyclohexene served as a test system in order to evaluate the capability of the detection systems. Experiments have been carried out in the TROPOS free-jet flow system at close to atmospheric conditions. Product ion signals were simultaneously observed by the ammonium-CI3-TOF and the acetate-CI-API-TOF. Both instruments are in remarkable good agreement within a factor of two for HOMs. For OMs not containing an OOH group the acetate technique can considerably underestimate OM concentrations by 2-3 orders of magnitude. First steps of cyclohexene ozonolysis generate ten different (m/z product peaks) main products comprising 92% of observed OMs. The remaining 8% are distributed over several (m/z peaks) minor products that can be attributed to HOMs, predominately to highly oxidized RO2 radicals. Summing up, observed ammonium-CI3-TOF products yield 4.9 x 109 molecules cm-³ in excellent agreement with the amount of reacted cyclohexene of 5.0 x 109 molecules cm-³ for reactant concentrations of [O3] = 2.25 x 1012 molecules cm-³ and [cyclohexene] = 2.0 x 1012 molecules cm-³ and a reaction time of 7.9 s. NH4+ adduct ion chemistry based CIMS techniques offer a unique opportunity for complete detection of the whole product distribution, and consequently, for a much better understanding of atmospheric oxidation processes.

  2. Generating variable and random schedules of reinforcement using Microsoft Excel macros.

    PubMed

    Bancroft, Stacie L; Bourret, Jason C

    2008-01-01

    Variable reinforcement schedules are used to arrange the availability of reinforcement following varying response ratios or intervals of time. Random reinforcement schedules are subtypes of variable reinforcement schedules that can be used to arrange the availability of reinforcement at a constant probability across number of responses or time. Generating schedule values for variable and random reinforcement schedules can be difficult. The present article describes the steps necessary to write macros in Microsoft Excel that will generate variable-ratio, variable-interval, variable-time, random-ratio, random-interval, and random-time reinforcement schedule values.

  3. Optimized protocol for quantitative multiple reaction monitoring-based proteomic analysis of formalin-fixed, paraffin embedded tissues

    PubMed Central

    Kennedy, Jacob J.; Whiteaker, Jeffrey R.; Schoenherr, Regine M.; Yan, Ping; Allison, Kimberly; Shipley, Melissa; Lerch, Melissa; Hoofnagle, Andrew N.; Baird, Geoffrey Stuart; Paulovich, Amanda G.

    2016-01-01

    Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin embedded (FFPE) tissues. While the feasibility of using targeted, multiple reaction monitoring-mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e. 9 processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R2 = 0.94) and immuno-MRM (R2 = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens. PMID:27462933

  4. Digitized hand-wrist radiographs: comparison of subjective and software-derived image quality at various compression ratios.

    PubMed

    McCord, Layne K; Scarfe, William C; Naylor, Rachel H; Scheetz, James P; Silveira, Anibal; Gillespie, Kevin R

    2007-05-01

    The objectives of this study were to compare the effect of JPEG 2000 compression of hand-wrist radiographs on observer image quality qualitative assessment and to compare with a software-derived quantitative image quality index. Fifteen hand-wrist radiographs were digitized and saved as TIFF and JPEG 2000 images at 4 levels of compression (20:1, 40:1, 60:1, and 80:1). The images, including rereads, were viewed by 13 orthodontic residents who determined the image quality rating on a scale of 1 to 5. A quantitative analysis was also performed by using a readily available software based on the human visual system (Image Quality Measure Computer Program, version 6.2, Mitre, Bedford, Mass). ANOVA was used to determine the optimal compression level (P < or =.05). When we compared subjective indexes, JPEG compression greater than 60:1 significantly reduced image quality. When we used quantitative indexes, the JPEG 2000 images had lower quality at all compression ratios compared with the original TIFF images. There was excellent correlation (R2 >0.92) between qualitative and quantitative indexes. Image Quality Measure indexes are more sensitive than subjective image quality assessments in quantifying image degradation with compression. There is potential for this software-based quantitative method in determining the optimal compression ratio for any image without the use of subjective raters.

  5. Time- and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse

    NASA Astrophysics Data System (ADS)

    Stauffer, Hans U.; Miller, Joseph D.; Slipchenko, Mikhail N.; Meyer, Terrence R.; Prince, Benjamin D.; Roy, Sukesh; Gord, James R.

    2014-01-01

    The hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) technique presents a promising alternative to either fs time-resolved or ps frequency-resolved CARS in both gas-phase thermometry and condensed-phase excited-state dynamics applications. A theoretical description of time-dependent CARS is used to examine this recently developed probe technique, and quantitative comparisons of the full time-frequency evolution show excellent accuracy in predicting the experimental vibrational CARS spectra obtained for two model systems. The interrelated time- and frequency-domain spectral signatures of gas-phase species produced by hybrid fs/ps CARS are explored with a focus on gas-phase N2 vibrational CARS, which is commonly used as a thermometric diagnostic of combusting flows. In particular, we discuss the merits of the simple top-hat spectral filter typically used to generate the ps-duration hybrid fs/ps CARS probe pulse, including strong discrimination against non-resonant background that often contaminates CARS signal. It is further demonstrated, via comparison with vibrational CARS results on a time-evolving solvated organic chromophore, that this top-hat probe-pulse configuration can provide improved spectral resolution, although the degree of improvement depends on the dephasing timescales of the observed molecular modes and the duration and timing of the narrowband final pulse. Additionally, we discuss the virtues of a frequency-domain Lorentzian probe-pulse lineshape and its potential for improving the hybrid fs/ps CARS technique as a diagnostic in high-pressure gas-phase thermometry applications.

  6. Time- and frequency-dependent model of time-resolved coherent anti-Stokes Raman scattering (CARS) with a picosecond-duration probe pulse.

    PubMed

    Stauffer, Hans U; Miller, Joseph D; Slipchenko, Mikhail N; Meyer, Terrence R; Prince, Benjamin D; Roy, Sukesh; Gord, James R

    2014-01-14

    The hybrid femtosecond∕picosecond coherent anti-Stokes Raman scattering (fs∕ps CARS) technique presents a promising alternative to either fs time-resolved or ps frequency-resolved CARS in both gas-phase thermometry and condensed-phase excited-state dynamics applications. A theoretical description of time-dependent CARS is used to examine this recently developed probe technique, and quantitative comparisons of the full time-frequency evolution show excellent accuracy in predicting the experimental vibrational CARS spectra obtained for two model systems. The interrelated time- and frequency-domain spectral signatures of gas-phase species produced by hybrid fs∕ps CARS are explored with a focus on gas-phase N2 vibrational CARS, which is commonly used as a thermometric diagnostic of combusting flows. In particular, we discuss the merits of the simple top-hat spectral filter typically used to generate the ps-duration hybrid fs∕ps CARS probe pulse, including strong discrimination against non-resonant background that often contaminates CARS signal. It is further demonstrated, via comparison with vibrational CARS results on a time-evolving solvated organic chromophore, that this top-hat probe-pulse configuration can provide improved spectral resolution, although the degree of improvement depends on the dephasing timescales of the observed molecular modes and the duration and timing of the narrowband final pulse. Additionally, we discuss the virtues of a frequency-domain Lorentzian probe-pulse lineshape and its potential for improving the hybrid fs∕ps CARS technique as a diagnostic in high-pressure gas-phase thermometry applications.

  7. Precisely detecting atomic position of atomic intensity images.

    PubMed

    Wang, Zhijun; Guo, Yaolin; Tang, Sai; Li, Junjie; Wang, Jincheng; Zhou, Yaohe

    2015-03-01

    We proposed a quantitative method to detect atomic position in atomic intensity images from experiments such as high-resolution transmission electron microscopy, atomic force microscopy, and simulation such as phase field crystal modeling. The evaluation of detection accuracy proves the excellent performance of the method. This method provides a chance to precisely determine atomic interactions based on the detected atomic positions from the atomic intensity image, and hence to investigate the related physical, chemical and electrical properties. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Molecular quenching and relaxation in a plasmonic tunable system

    NASA Astrophysics Data System (ADS)

    Baffou, Guillaume; Girard, Christian; Dujardin, Erik; Colas Des Francs, Gérard; Martin, Olivier J. F.

    2008-03-01

    Molecular fluorescence decay is significantly modified when the emitting molecule is located near a plasmonic structure. When the lateral sizes of such structures are reduced to nanometer-scale cross sections, they can be used to accurately control and amplify the emission rate. In this Rapid Communication, we extend Green’s dyadic method to quantitatively investigate both radiative and nonradiative decay channels experienced by a single fluorescent molecule confined in an adjustable dielectric-metal nanogap. The technique produces data in excellent agreement with current experimental work.

  9. Validation Results for LEWICE 2.0. [Supplement

    NASA Technical Reports Server (NTRS)

    Wright, William B.; Rutkowski, Adam

    1999-01-01

    Two CD-ROMs contain experimental ice shapes and code prediction used for validation of LEWICE 2.0 (see NASA/CR-1999-208690, CASI ID 19990021235). The data include ice shapes for both experiment and for LEWICE, all of the input and output files for the LEWICE cases, JPG files of all plots generated, an electronic copy of the text of the validation report, and a Microsoft Excel(R) spreadsheet containing all of the quantitative measurements taken. The LEWICE source code and executable are not contained on the discs.

  10. High Thermoelectric Performance by Convergence of Bands in IV-VI Semiconductors, Heavily Doped PbTe, and Alloys/Nanocomposites

    NASA Technical Reports Server (NTRS)

    Snyder, G. Jeffrey (Inventor); Pei, Yanzhong (Inventor)

    2015-01-01

    The present invention teaches an effective mechanism for enhancing thermoelectric performance through additional conductive bands. Using heavily doped p-PbTe materials as an example, a quantitative explanation is disclosed, as to why and how these additional bands affect the figure of merit. A high zT of approaching 2 at high temperatures makes these simple, likely more stable (than nanostructured materials) and Tl-free materials excellent for thermoelectric applications.

  11. Defense Acquisition Review Journal. Volume 17, Number 2, Issue 54. Achieving Excellence in a Changing Acquisition Environment

    DTIC Science & Technology

    2010-04-01

    CommunityBrowser.aspx?id=24530&lang=en-US Bryman , A. (1984). The debate about quantitative and qualitative research : A question of method or...in the DoD’s structure— indeed, the organization’s very way of “doing business ”—will prove a daunting task. The rationale for the research ...opportunity to provide leadership training at the entry- and mid-levels to the AT&L Workforce? Method This article’s research question involves the

  12. Training anesthesiology residents in providing anesthesia for awake craniotomy: learning curves and estimate of needed case load.

    PubMed

    Bilotta, Federico; Titi, Luca; Lanni, Fabiana; Stazi, Elisabetta; Rosa, Giovanni

    2013-08-01

    To measure the learning curves of residents in anesthesiology in providing anesthesia for awake craniotomy, and to estimate the case load needed to achieve a "good-excellent" level of competence. Prospective study. Operating room of a university hospital. 7 volunteer residents in anesthesiology. Residents underwent a dedicated training program of clinical characteristics of anesthesia for awake craniotomy. The program was divided into three tasks: local anesthesia, sedation-analgesia, and intraoperative hemodynamic management. The learning curve for each resident for each task was recorded over 10 procedures. Quantitative assessment of the individual's ability was based on the resident's self-assessment score and the attending anesthesiologist's judgment, and rated by modified 12 mm Likert scale, reported ability score visual analog scale (VAS). This ability VAS score ranged from 1 to 12 (ie, very poor, mild, moderate, sufficient, good, excellent). The number of requests for advice also was recorded (ie, resident requests for practical help and theoretical notions to accomplish the procedures). Each task had a specific learning rate; the number of procedures necessary to achieve "good-excellent" ability with confidence, as determined by the recorded results, were 10 procedures for local anesthesia, 15 to 25 procedures for sedation-analgesia, and 20 to 30 procedures for intraoperative hemodynamic management. Awake craniotomy is an approach used increasingly in neuroanesthesia. A dedicated training program based on learning specific tasks and building confidence with essential features provides "good-excellent" ability. © 2013 Elsevier Inc. All rights reserved.

  13. Evaluation of process excellence tools in improving donor flow management in a tertiary care hospital in South India

    PubMed Central

    Venugopal, Divya; Rafi, Aboobacker Mohamed; Innah, Susheela Jacob; Puthayath, Bibin T.

    2017-01-01

    BACKGROUND: Process Excellence is a value based approach and focuses on standardizing work processes by eliminating the non-value added processes, identify process improving methodologies and maximize capacity and expertise of the staff. AIM AND OBJECTIVES: To Evaluate the utility of Process Excellence Tools in improving Donor Flow Management in a Tertiary care Hospital by studying the current state of donor movement within the blood bank and providing recommendations for eliminating the wait times and to improve the process and workflow. MATERIALS AND METHODS: The work was done in two phases; The First Phase comprised of on-site observations with the help of an expert trained in Process Excellence Methodology who observed and documented various aspects of donor flow, donor turn around time, total staff details and operator process flow. The Second Phase comprised of constitution of a Team to analyse the data collected. The analyzed data along with the recommendations were presented before an expert hospital committee and the management. RESULTS: Our analysis put forward our strengths and identified potential problems. Donor wait time was reduced by 50% after lean due to better donor management with reorganization of the infrastructure of the donor area. Receptionist tracking showed that 62% of the total time the staff wastes in walking and 22% in other non-value added activities. Defining Duties for each staff reduced the time spent by them in non-value added activities. Implementation of the token system, generation of unique identification code for donors and bar code labeling of the tubes and bags are among the other recommendations. CONCLUSION: Process Excellence is not a programme; it's a culture that transforms an organization and improves its Quality and Efficiency through new attitudes, elimination of wastes and reduction in costs. PMID:28970681

  14. Evaluation of process excellence tools in improving donor flow management in a tertiary care hospital in South India.

    PubMed

    Venugopal, Divya; Rafi, Aboobacker Mohamed; Innah, Susheela Jacob; Puthayath, Bibin T

    2017-01-01

    Process Excellence is a value based approach and focuses on standardizing work processes by eliminating the non-value added processes, identify process improving methodologies and maximize capacity and expertise of the staff. To Evaluate the utility of Process Excellence Tools in improving Donor Flow Management in a Tertiary care Hospital by studying the current state of donor movement within the blood bank and providing recommendations for eliminating the wait times and to improve the process and workflow. The work was done in two phases; The First Phase comprised of on-site observations with the help of an expert trained in Process Excellence Methodology who observed and documented various aspects of donor flow, donor turn around time, total staff details and operator process flow. The Second Phase comprised of constitution of a Team to analyse the data collected. The analyzed data along with the recommendations were presented before an expert hospital committee and the management. Our analysis put forward our strengths and identified potential problems. Donor wait time was reduced by 50% after lean due to better donor management with reorganization of the infrastructure of the donor area. Receptionist tracking showed that 62% of the total time the staff wastes in walking and 22% in other non-value added activities. Defining Duties for each staff reduced the time spent by them in non-value added activities. Implementation of the token system, generation of unique identification code for donors and bar code labeling of the tubes and bags are among the other recommendations. Process Excellence is not a programme; it's a culture that transforms an organization and improves its Quality and Efficiency through new attitudes, elimination of wastes and reduction in costs.

  15. RosettaHoles: rapid assessment of protein core packing for structure prediction, refinement, design, and validation.

    PubMed

    Sheffler, Will; Baker, David

    2009-01-01

    We present a novel method called RosettaHoles for visual and quantitative assessment of underpacking in the protein core. RosettaHoles generates a set of spherical cavity balls that fill the empty volume between atoms in the protein interior. For visualization, the cavity balls are aggregated into contiguous overlapping clusters and small cavities are discarded, leaving an uncluttered representation of the unfilled regions of space in a structure. For quantitative analysis, the cavity ball data are used to estimate the probability of observing a given cavity in a high-resolution crystal structure. RosettaHoles provides excellent discrimination between real and computationally generated structures, is predictive of incorrect regions in models, identifies problematic structures in the Protein Data Bank, and promises to be a useful validation tool for newly solved experimental structures.

  16. Analytical methods for toxic gases from thermal degradation of polymers

    NASA Technical Reports Server (NTRS)

    Hsu, M.-T. S.

    1977-01-01

    Toxic gases evolved from the thermal oxidative degradation of synthetic or natural polymers in small laboratory chambers or in large scale fire tests are measured by several different analytical methods. Gas detector tubes are used for fast on-site detection of suspect toxic gases. The infrared spectroscopic method is an excellent qualitative and quantitative analysis for some toxic gases. Permanent gases such as carbon monoxide, carbon dioxide, methane and ethylene, can be quantitatively determined by gas chromatography. Highly toxic and corrosive gases such as nitrogen oxides, hydrogen cyanide, hydrogen fluoride, hydrogen chloride and sulfur dioxide should be passed into a scrubbing solution for subsequent analysis by either specific ion electrodes or spectrophotometric methods. Low-concentration toxic organic vapors can be concentrated in a cold trap and then analyzed by gas chromatography and mass spectrometry. The limitations of different methods are discussed.

  17. RosettaHoles: Rapid assessment of protein core packing for structure prediction, refinement, design, and validation

    PubMed Central

    Sheffler, Will; Baker, David

    2009-01-01

    We present a novel method called RosettaHoles for visual and quantitative assessment of underpacking in the protein core. RosettaHoles generates a set of spherical cavity balls that fill the empty volume between atoms in the protein interior. For visualization, the cavity balls are aggregated into contiguous overlapping clusters and small cavities are discarded, leaving an uncluttered representation of the unfilled regions of space in a structure. For quantitative analysis, the cavity ball data are used to estimate the probability of observing a given cavity in a high-resolution crystal structure. RosettaHoles provides excellent discrimination between real and computationally generated structures, is predictive of incorrect regions in models, identifies problematic structures in the Protein Data Bank, and promises to be a useful validation tool for newly solved experimental structures. PMID:19177366

  18. Quantifying the effect of ionic screening with protein-decorated graphene transistors

    PubMed Central

    Ping, Jinglei; Xi, Jin; Saven, Jeffery G.; Liu, Renyu; Charlie Johnson, A. T.

    2015-01-01

    Liquid-based applications of biomolecule-decorated field-effect transistors (FETs) range from biosensors to in vivo implants. A critical scientific challenge is to develop a quantitative understanding of the gating effect of charged biomolecules in ionic solution and how this influences the readout of the FETs. To address this issue, we fabricated protein-decorated graphene FETs and measured their electrical properties, specifically the shift in Dirac voltage, in solutions of varying ionic strength. We found excellent quantitative agreement with a model that accounts for both the graphene polarization charge and ionic screening of ions adsorbed on the graphene as well as charged amino acids associated with the immobilized protein. The technique and analysis presented here directly couple the charging status of bound biomolecules to readout of liquid-phase FETs fabricated with graphene or other two-dimensional materials. PMID:26626969

  19. Comprehensive comparison of self-administered questionnaires for measuring quantitative autistic traits in adults.

    PubMed

    Nishiyama, Takeshi; Suzuki, Masako; Adachi, Katsunori; Sumi, Satoshi; Okada, Kensuke; Kishino, Hirohisa; Sakai, Saeko; Kamio, Yoko; Kojima, Masayo; Suzuki, Sadao; Kanne, Stephen M

    2014-05-01

    We comprehensively compared all available questionnaires for measuring quantitative autistic traits (QATs) in terms of reliability and construct validity in 3,147 non-clinical and 60 clinical subjects with normal intelligence. We examined four full-length forms, the Subthreshold Autism Trait Questionnaire (SATQ), the Broader Autism Phenotype Questionnaire, the Social Responsiveness Scale2-Adult Self report (SRS2-AS), and the Autism-Spectrum Quotient (AQ). The SRS2-AS and the AQ each had several short forms that we also examined, bringing the total to 11 forms. Though all QAT questionnaires showed acceptable levels of test-retest reliability, the AQ and SRS2-AS, including their short forms, exhibited poor internal consistency and discriminant validity, respectively. The SATQ excelled in terms of classical test theory and due to its short length.

  20. Simultaneous multislice diffusion-weighted MRI of the liver: Analysis of different breathing schemes in comparison to standard sequences.

    PubMed

    Taron, Jana; Martirosian, Petros; Erb, Michael; Kuestner, Thomas; Schwenzer, Nina F; Schmidt, Holger; Honndorf, Valerie S; Weiβ, Jakob; Notohamiprodjo, Mike; Nikolaou, Konstantin; Schraml, Christina

    2016-10-01

    To systematically evaluate image characteristics of simultaneous-multislice (SMS)-accelerated diffusion-weighted imaging (DWI) of the liver using different breathing schemes in comparison to standard sequences. DWI of the liver was performed in 10 healthy volunteers and 12 patients at 1.5T using an SMS-accelerated echo planar imaging sequence performed with respiratory-triggering and free breathing (SMS-RT, SMS-FB). Standard DWI sequences served as reference (STD-RT, STD-FB). Reduction of scan time by SMS-acceleration was measured. Image characteristics of SMS-DWI and STD-DWI with both breathing schemes were analyzed quantitatively (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR]) and qualitatively (5-point Likert scale, 5 = excellent). Qualitative and quantitative parameters were compared using Friedman test and Dunn-Bonferroni post-hoc method with P-values < 0.05 considered statistically significant. SMS-DWI provided diagnostic image quality in volunteers and patients both with RT and FB with a reduction of scan time of 70% (0:56 vs. 3:20 min in FB). Overall image quality did not significantly differ between FB and RT acquisition in both STD and SMS sequences (median STD-RT 5.0, STD-FB 4.5, SMS-RT: 4.75; SMS-FB: 4.5; P = 0.294). SNR in the right hepatic lobe was comparable between the four tested sequences. ADC values were significantly lower in SMS-DWI compared to STD-DWI irrespective of the breathing scheme (1.2 ± 0.2 × 10(-3) mm(2) /s vs. 1.0 ± 0.2 × 10(-3) mm(2) /s; P < 0.001). SMS-acceleration provides considerable scan time reduction for hepatic DWI with equivalent image quality compared to the STD technique both using RT and FB. Discrepancies in ADC between STD-DWI and SMS-DWI need to be considered when transferring the SMS technique to clinical routine reading. J. MAGN. RESON. IMAGING 2016;44:865-879. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Organic Cyanide Decorated SERS Active Nanopipettes for Quantitative Detection of Hemeproteins and Fe3+ in Single Cells.

    PubMed

    Hanif, Sumaira; Liu, Hailing; Chen, Ming; Muhammad, Pir; Zhou, Yue; Cao, Jiao; Ahmed, Saud Asif; Xu, Jingjuan; Xia, Xinghua; Chen, Hongyuan; Wang, Kang

    2017-02-21

    It is challenging to develop a robust nanoprobe for real-time operational and accurate detection of heavy metals in single cells. Fe-CN coordination chemistry has been well studied to determine the structural characteristics of hemeproteins by different techniques. However, the frequently used cyanide ligands are inorganic molecules that release cyanide anion under particular conditions and cause cyanide poisoning. In the present study, organic cyanide (4-mercaptobenzonitrile, MBN) was utilized for the first time in developing a facile nanoprobe based on surface-enhanced Raman scattering (SERS) for quantitative detection of hemeproteins (oxy-Hb) and trivalent iron (Fe 3+ ) ions. The nanoprobe prepared by coating the glass capillary tip (100 nm) with a thin gold film, which enables highly localized study in living cell system. The cyanide stretching vibration in MBN was highly sensitive and selective to Fe 3+ and oxy-Hb with excellent binding affinity (K d 0.4 pM and 0.1 nM, respectively). The high sensitivity of the nanoprobe to analyte (Fe 3+ ) was attributed to the two adsorption conformations (-SH and -CN) of MBN to the gold surface. Therefore, MBN showed an exceptional dual-peak (2126 and 2225 cm -1 ) behavior. Furthermore, the special Raman peaks of cyanide in 2100-2300 cm -1 (silent region of SERS spectra) are distinguishable from other biomolecules characteristic peaks. The selective detection of Fe 3+ in both free and protein-bound states in aqueous solution is achieved with 0.1 pM and 0.08 μM levels of detection limits, respectively. Furthermore, practical applicability of fabricated nanoprobe was validated by detection of free Fe 3+ in pretreated living HeLa cells by direct insertion of a SERS active nanoprobe. Regarding the appropriate precision, good reproducibility (relative standard deviation, RSD 7.2-7.6%), and recyclability (retain good Raman intensity even after three renewing cycles) of the method, the developed sensing strategy on a nanopipette has potential benefits for label-free, qualitative and quantitative recognition of heavy metal ions within nanoliter volumes.

  2. Rapid video-referenced ratings of reciprocal social behavior in toddlers: a twin study.

    PubMed

    Marrus, Natasha; Glowinski, Anne L; Jacob, Theodore; Klin, Ami; Jones, Warren; Drain, Caroline E; Holzhauer, Kieran E; Hariprasad, Vaishnavi; Fitzgerald, Robert T; Mortenson, Erika L; Sant, Sayli M; Cole, Lyndsey; Siegel, Satchel A; Zhang, Yi; Agrawal, Arpana; Heath, Andrew C; Constantino, John N

    2015-12-01

    Reciprocal social behavior (RSB) is a developmental prerequisite for social competency, and deficits in RSB constitute a core feature of autism spectrum disorder (ASD). Although clinical screeners categorically ascertain risk of ASD in early childhood, rapid methods for quantitative measurement of RSB in toddlers are not yet established. Such measurements are critical for tracking developmental trajectories and incremental responses to intervention. We developed and validated a 20-min video-referenced rating scale, the video-referenced rating of reciprocal social behavior (vrRSB), for untrained caregivers to provide standardized ratings of quantitative variation in RSB. Parents of 252 toddler twins [Monozygotic (MZ) = 31 pairs, Dizygotic (DZ) = 95 pairs] ascertained through birth records, rated their twins' RSB at two time points, on average 6 months apart, and completed two developmental measures, the Modified Checklist for Autism in Toddlers (M-CHAT) and the MacArthur Communicative Development Inventory Short Form (MCDI-s). Scores on the vrRSB were fully continuously distributed, with excellent 6-month test-retest reliability ([intraclass correlation coefficient] ICC = 0.704, p < .000). MZ twins displayed markedly greater trait concordance than DZ twins, (MZ ICC = 0.863, p < .000, DZ ICC = 0.231, p < .012). VrRSB score distributions were highly distinct for children passing versus failing the M-CHAT (t = -8.588, df = 31, p < .000), incrementally improved from 18-24 months, and were inversely correlated with receptive and expressive vocabulary on the MCDI-s. Like quantitative autistic trait ratings in school-aged children and adults, toddler scores on the vrRSB are continuously distributed and appear highly heritable. These ratings exhibited minimal measurement error, high inter-individual stability, and developmental progression in RSB as children matured from 18-24 months, supporting their potential utility for serially quantifying the severity of early autistic syndromes over time and in response to intervention. In addition, these findings inform the genetic-environmental structure of RSB in early typical development. © 2015 Association for Child and Adolescent Mental Health.

  3. Blueprint for an Indian Nobel Laureate in Psychiatry*

    PubMed Central

    Singh, Ajai R.

    2015-01-01

    There are a number of spoofs and light-hearted writings in blogs, journalistic pieces and book form (even from former Nobel Laureates), which attempt at ‘understanding’ the secret of getting a Nobel. This is not one of them. It is more pedantic without necessarily being dry. It first analyses the meaning of the concept, ‘the greatest benefit of mankind’, which is the crux of the Nobel Will and the overarching requirement for a Nobel in Medicine. Further discussion in the paper is divided into 5 parts: (1)General qualities for a Nobel: The need to be really bright is a given; what is necessary is to be sufficiently crazy about a research topic to make it an obsession; be ready to forgo many creature comforts for long stretches of time; and after all this, be ready to accept that the Nobel may never happen, yet continue to do a type of research solely because it is intrinsically worth doing.(2)Nobel in Physiology or Medicine: Here, the key is to do fundamental/basic research to answer persistent, nagging, unanswered questions of medicine which others neglect because they are discomforting. Or, find treatments that change the whole manner a disease has been hitherto treated.(3)Nobel in Psychiatry: There are many Nobels waiting to be won, provided: (a) The branch becomes more precise; (b) Science, quantitative study and biology remain its bedrock; and (c) There is an almost obsessive preoccupation with unravelling the mysteries of the brain. One has to choose wisely where to put in efforts, e.g., fields like fundamental research into the causes of psychiatric disorders, especially schizophrenia, depression, bipolar disorders. Or their definitive treatments. Or, work at the cellular or molecular level of the neuron and brain; or, the glandular or genetic level of the systems connected with psychiatric disorders; or, in brain radio imaging. If other, or allied, fields are chosen, to work with finding quantitative data and attempt to pinpoint their precise biological correlates.(4)Indian Nobel in Medicine: There is first the need to give up the colonial mindset that everything trend-setting in science comes only from the West. As also, for Departmental Heads, to protect and nurture those with research excellence rather than the mediocre and the sycophants. For governments, to set up an autonomous Research Excellence Council to expressly and exclusively cater to promoting research excellence, with a sizeable fund to put this into practice.All these four points are summarised as four rules.(5)Indian Nobel in psychiatry: Practical suggestions are presented in the form of an 11 Point Action Plan based on 1-4 above. PMID:25838739

  4. Advances in Surface Plasmon Resonance Imaging enable quantitative measurement of laterally heterogeneous coatings of nanoscale thickness

    NASA Astrophysics Data System (ADS)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2013-03-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to the optical properties of nanoscale coatings on thin metallic surfaces, for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases - uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. We first demonstrate the directionally heterogeneous nature of the SPR phenomenon using a directionally ordered sample, then show how this allows for the calculation of the average coverage of a heterogeneous sample. Finally, the degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  5. Development of a comprehensive analytical platform for the detection and quantitation of food fraud using a biomarker approach. The oregano adulteration case study.

    PubMed

    Wielogorska, Ewa; Chevallier, Olivier; Black, Connor; Galvin-King, Pamela; Delêtre, Marc; Kelleher, Colin T; Haughey, Simon A; Elliott, Christopher T

    2018-01-15

    Due to increasing number of food fraud incidents, there is an inherent need for the development and implementation of analytical platforms enabling detection and quantitation of adulteration. In this study a set of unique biomarkers of commonly found oregano adulterants became the targets in the development of a LC-MS/MS method which underwent a rigorous in-house validation. The method presented very high selectivity and specificity, excellent linearity (R 2 >0.988) low decision limits and detection capabilities (<2%), acceptable accuracy (intra-assay 92-113%, inter-assay 69-138%) and precision (CV<20%). The method was compared with an established FTIR screening assay and revealed a good correlation of quali- and quantitative results (R 2 >0.81). An assessment of 54 suspected adulterated oregano samples revealed that almost 90% of them contained at least one bulking agent, with a median level of adulteration of 50%. Such innovative methodologies need to be established as routine testing procedures to detect and ultimately deter food fraud. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. A quantitative model to assess Social Responsibility in Environmental Science and Technology.

    PubMed

    Valcárcel, M; Lucena, R

    2014-01-01

    The awareness of the impact of human activities in society and environment is known as "Social Responsibility" (SR). It has been a topic of growing interest in many enterprises since the fifties of the past Century, and its implementation/assessment is nowadays supported by international standards. There is a tendency to amplify its scope of application to other areas of the human activities, such as Research, Development and Innovation (R + D + I). In this paper, a model of quantitative assessment of Social Responsibility in Environmental Science and Technology (SR EST) is described in detail. This model is based on well established written standards as the EFQM Excellence model and the ISO 26000:2010 Guidance on SR. The definition of five hierarchies of indicators, the transformation of qualitative information into quantitative data and the dual procedure of self-evaluation and external evaluation are the milestones of the proposed model, which can be applied to Environmental Research Centres and institutions. In addition, a simplified model that facilitates its implementation is presented in the article. © 2013 Elsevier B.V. All rights reserved.

  7. Description and prediction of time-to-attainment of excellent recovery for borderline patients followed prospectively for 20 years.

    PubMed

    Zanarini, Mary C; Temes, Christina M; Frankenburg, Frances R; Reich, D Bradford; Fitzmaurice, Garrett M

    2018-04-01

    One purpose of this study was to determine the cumulative rates of excellent recovery for borderline patients and axis II comparison subjects followed prospectively for 20 years. Another purpose was to find the best set of baseline predictors of excellent recovery for borderline patients. A total of 290 inpatients meeting rigorous criteria for borderline personality disorder and 72 axis II comparison subjects completed semistructured interviews and self-report measures during their index admission. Subjects were reassessed prospectively over 10 contiguous two-year waves of follow-up. Thirty-nine percent of borderline patients and 73% of personality-disordered comparison subjects met our operationalized definition of excellent recovery (concurrent remission of borderline or another primary personality disorder, good social and full-time vocational functioning, and absence of an axis I disorder associated decreased social and/or vocational functioning). Five variables formed our multivariate predictive model of excellent recovery for borderline patients: higher IQ, good childhood work history, good adult vocational record, lower trait neuroticism, and higher trait agreeableness. The results of this study suggest that complete recovery is difficult for borderline patients to achieve even over long periods of time. They also suggest that competence displayed in both childhood and adulthood is the best predictor of this important outcome. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    PubMed

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaplan, C.R.; Shaddix, C.R.; Smyth, K.C.

    This paper presents time-dependent numerical simulations of both steady and time-varying CH{sub 4}/air diffusion flames to examine the differences in combustion conditions which lead to the observed enhancement in soot production in the flickering flames. The numerical model solves the two-dimensional, time-dependent, reactive-flow Navier-Stokes equations coupled with submodels for soot formation and radiation transport. Qualitative comparisons between the experimental and computed steady flame show good agreement for the soot burnout height and overall flame shape except near the burner lip. Quantitative comparisons between experimental and computed radial profiles of temperature and soot volume fraction for the steady flame show goodmore » to excellent agreement at mid-flame heights, but some discrepancies near the burner lip and at high flame heights. For the time-varying CH{sub 4}/air flame, the simulations successfully predict that the maximum soot concentration increases by over four times compared to the steady flame with the same mean fuel and air velocities. By numerically tracking fluid parcels in the flowfield, the temperature and stoichiometry history were followed along their convective pathlines. Results for the pathline which passes through the maximum sooting region show that flickering flames exhibit much longer residence times during which the local temperatures and stoichiometries are favorable for soot production. The simulations also suggest that soot inception occurs later in flickering flames, and at slightly higher temperatures and under somewhat leaner conditions compared to the steady flame. The integrated soot model of Syed et al., which was developed from a steady CH{sub 4}/air flame, successfully predicts soot production in the time-varying CH{sub 4}/air flames.« less

  10. Generating Variable and Random Schedules of Reinforcement Using Microsoft Excel Macros

    PubMed Central

    Bancroft, Stacie L; Bourret, Jason C

    2008-01-01

    Variable reinforcement schedules are used to arrange the availability of reinforcement following varying response ratios or intervals of time. Random reinforcement schedules are subtypes of variable reinforcement schedules that can be used to arrange the availability of reinforcement at a constant probability across number of responses or time. Generating schedule values for variable and random reinforcement schedules can be difficult. The present article describes the steps necessary to write macros in Microsoft Excel that will generate variable-ratio, variable-interval, variable-time, random-ratio, random-interval, and random-time reinforcement schedule values. PMID:18595286

  11. Target-responsive DNAzyme cross-linked hydrogel for visual quantitative detection of lead.

    PubMed

    Huang, Yishun; Ma, Yanli; Chen, Yahong; Wu, Xuemeng; Fang, Luting; Zhu, Zhi; Yang, Chaoyong James

    2014-11-18

    Because of the severe health risks associated with lead pollution, rapid, sensitive, and portable detection of low levels of Pb(2+) in biological and environmental samples is of great importance. In this work, a Pb(2+)-responsive hydrogel was prepared using a DNAzyme and its substrate as cross-linker for rapid, sensitive, portable, and quantitative detection of Pb(2+). Gold nanoparticles (AuNPs) were first encapsulated in the hydrogel as an indicator for colorimetric analysis. In the absence of lead, the DNAzyme is inactive, and the substrate cross-linker maintains the hydrogel in the gel form. In contrast, the presence of lead activates the DNAzyme to cleave the substrate, decreasing the cross-linking density of the hydrogel and resulting in dissolution of the hydrogel and release of AuNPs for visual detection. As low as 10 nM Pb(2+) can be detected by the naked eye. Furthermore, to realize quantitative visual detection, a volumetric bar-chart chip (V-chip) was used for quantitative readout of the hydrogel system by replacing AuNPs with gold-platinum core-shell nanoparticles (Au@PtNPs). The Au@PtNPs released from the hydrogel upon target activation can efficiently catalyze the decomposition of H2O2 to generate a large volume of O2. The gas pressure moves an ink bar in the V-chip for portable visual quantitative detection of lead with a detection limit less than 5 nM. The device was able to detect lead in digested blood with excellent accuracy. The method developed can be used for portable lead quantitation in many applications. Furthermore, the method can be further extended to portable visual quantitative detection of a variety of targets by replacing the lead-responsive DNAzyme with other DNAzymes.

  12. Achieving Educational Excellence for Children at Risk. Selected Papers from the NASW National School Social Work Conference, "Educational Excellence in Transitional Times" (3rd, New Orleans, Louisiana, January 31-February 3, 1985).

    ERIC Educational Resources Information Center

    Hawkins, Mable T., Ed.

    This book consists of selected conference papers that highlight the barriers faced by children at risk in the quest for educational excellence. After an introduction by Mable T. Hawkins, the following articles appear: (1) "Group Work with Gifted Children: A School Resource," by Jackolyn W. Durrett and others; (2) "Children with…

  13. Excel2Genie: A Microsoft Excel application to improve the flexibility of the Genie-2000 Spectroscopic software.

    PubMed

    Forgács, Attila; Balkay, László; Trón, Lajos; Raics, Péter

    2014-12-01

    Excel2Genie, a simple and user-friendly Microsoft Excel interface, has been developed to the Genie-2000 Spectroscopic Software of Canberra Industries. This Excel application can directly control Canberra Multichannel Analyzer (MCA), process the acquired data and visualize them. Combination of Genie-2000 with Excel2Genie results in remarkably increased flexibility and a possibility to carry out repetitive data acquisitions even with changing parameters and more sophisticated analysis. The developed software package comprises three worksheets: display parameters and results of data acquisition, data analysis and mathematical operations carried out on the measured gamma spectra. At the same time it also allows control of these processes. Excel2Genie is freely available to assist gamma spectrum measurements and data evaluation by the interested Canberra users. With access to the Visual Basic Application (VBA) source code of this application users are enabled to modify the developed interface according to their intentions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Analysis of mathematical literacy ability based on self-efficacy in model eliciting activities using metaphorical thinking approach

    NASA Astrophysics Data System (ADS)

    Setiani, C.; Waluya, S. B.; Wardono

    2018-03-01

    The purposes of this research are: (1) to identify learning quality in Model Eliciting Activities (MEAs) using a Metaphorical Thinking (MT) approach regarding qualitative and quantitative; (2) to analyze mathematical literacy of students based on Self-Efficacy (SE). This research is mixed method concurrent embedded design with qualitative research as the primary method. The quantitative research used quasi-experimental with non-equivalent control group design. The population is VIII grade students of SMP Negeri 3 Semarang Indonesia. Quantitative data is examined by conducting completeness mean test, standard completeness test, mean differentiation test and proportional differentiation test. Qualitative data is analyzed descriptively. The result of this research shows that MEAs learning using MT approach accomplishes good criteria both quantitatively and qualitatively. Students with low self-efficacy can identify problems, but they are lack ability to arrange problem-solving strategy on mathematical literacy questions. Students with medium self-efficacy can identify information provided in issues, but they find difficulties to use math symbols in making a representation. Students with high self-efficacy are excellent to represent problems into mathematical models as well as figures by using appropriate symbols and tools, so they can arrange strategy easily to solve mathematical literacy questions.

  15. Quantitative inference of population response properties across eccentricity from motion-induced maps in macaque V1

    PubMed Central

    Chen, Ming; Wu, Si; Lu, Haidong D.; Roe, Anna W.

    2013-01-01

    Interpreting population responses in the primary visual cortex (V1) remains a challenge especially with the advent of techniques measuring activations of large cortical areas simultaneously with high precision. For successful interpretation, a quantitatively precise model prediction is of great importance. In this study, we investigate how accurate a spatiotemporal filter (STF) model predicts average response profiles to coherently drifting random dot motion obtained by optical imaging of intrinsic signals in V1 of anesthetized macaques. We establish that orientation difference maps, obtained by subtracting orthogonal axis-of-motion, invert with increasing drift speeds, consistent with the motion streak effect. Consistent with perception, the speed at which the map inverts (the critical speed) depends on cortical eccentricity and systematically increases from foveal to parafoveal. We report that critical speeds and response maps to drifting motion are excellently reproduced by the STF model. Our study thus suggests that the STF model is quantitatively accurate enough to be used as a first model of choice for interpreting responses obtained with intrinsic imaging methods in V1. We show further that this good quantitative correspondence opens the possibility to infer otherwise not easily accessible population receptive field properties from responses to complex stimuli, such as drifting random dot motions. PMID:23197457

  16. Advanced body composition assessment: from body mass index to body composition profiling.

    PubMed

    Borga, Magnus; West, Janne; Bell, Jimmy D; Harvey, Nicholas C; Romu, Thobias; Heymsfield, Steven B; Dahlqvist Leinhard, Olof

    2018-06-01

    This paper gives a brief overview of common non-invasive techniques for body composition analysis and a more in-depth review of a body composition assessment method based on fat-referenced quantitative MRI. Earlier published studies of this method are summarized, and a previously unpublished validation study, based on 4753 subjects from the UK Biobank imaging cohort, comparing the quantitative MRI method with dual-energy X-ray absorptiometry (DXA) is presented. For whole-body measurements of adipose tissue (AT) or fat and lean tissue (LT), DXA and quantitative MRIs show excellent agreement with linear correlation of 0.99 and 0.97, and coefficient of variation (CV) of 4.5 and 4.6 per cent for fat (computed from AT) and LT, respectively, but the agreement was found significantly lower for visceral adipose tissue, with a CV of >20 per cent. The additional ability of MRI to also measure muscle volumes, muscle AT infiltration and ectopic fat, in combination with rapid scanning protocols and efficient image analysis tools, makes quantitative MRI a powerful tool for advanced body composition assessment. © American Federation for Medical Research (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

    PubMed

    Sciagrà, Roberto; Passeri, Alessandro; Bucerius, Jan; Verberne, Hein J; Slart, Riemer H J A; Lindner, Oliver; Gimelli, Alessia; Hyafil, Fabien; Agostini, Denis; Übleis, Christopher; Hacker, Marcus

    2016-07-01

    Until recently, PET was regarded as a luxurious way of performing myocardial perfusion scintigraphy, with excellent image quality and diagnostic capabilities that hardly justified the additional cost and procedural effort. Quantitative perfusion PET was considered a major improvement over standard qualitative imaging, because it allows the measurement of parameters not otherwise available, but for many years its use was confined to academic and research settings. In recent years, however, several factors have contributed to the renewal of interest in quantitative perfusion PET, which has become a much more readily accessible technique due to progress in hardware and the availability of dedicated and user-friendly platforms and programs. In spite of this evolution and of the growing evidence that quantitative perfusion PET can play a role in the clinical setting, there are not yet clear indications for its clinical use. Therefore, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, decided to examine the current literature on quantitative perfusion PET to (1) evaluate the rationale for its clinical use, (2) identify the main methodological requirements, (3) identify the remaining technical difficulties, (4) define the most reliable interpretation criteria, and finally (5) tentatively delineate currently acceptable and possibly appropriate clinical indications. The present position paper must be considered as a starting point aiming to promote a wider use of quantitative perfusion PET and to encourage the conception and execution of the studies needed to definitely establish its role in clinical practice.

  18. A systematic review of the health and well-being impacts of school gardening: synthesis of quantitative and qualitative evidence.

    PubMed

    Ohly, Heather; Gentry, Sarah; Wigglesworth, Rachel; Bethel, Alison; Lovell, Rebecca; Garside, Ruth

    2016-03-25

    School gardening programmes are increasingly popular, with suggested benefits including healthier eating and increased physical activity. Our objectives were to understand the health and well-being impacts of school gardens and the factors that help or hinder their success. We conducted a systematic review of quantitative and qualitative evidence (PROSPERO CRD42014007181). We searched multiple databases and used a range of supplementary approaches. Studies about school gardens were included if they reported on physical or mental health or well-being. Quantitative studies had to include a comparison group. Studies were quality appraised using appropriate tools. Findings were narratively synthesised and the qualitative evidence used to produce a conceptual framework to illustrate how benefits might be accrued. Evidence from 40 articles (21 quantitative studies; 16 qualitative studies; 3 mixed methods studies) was included. Generally the quantitative research was poor. Evidence for changes in fruit and vegetable intake was limited and based on self-report. The qualitative research was better quality and ascribed a range of health and well-being impacts to school gardens, with some idealistic expectations for their impact in the long term. Groups of pupils who do not excel in classroom activities were thought to particularly benefit. Lack of funding and over reliance on volunteers were thought to threaten success, while involvement with local communities and integration of gardening activities into the school curriculum were thought to support success. More robust quantitative research is needed to convincingly support the qualitative evidence suggesting wide ranging benefits from school gardens.

  19. Self-scheduling with Microsoft Excel.

    PubMed

    Irvin, S A; Brown, H N

    1999-01-01

    Excessive time was being spent by the emergency department (ED) staff, head nurse, and unit secretary on a complex 6-week manual self-scheduling system. This issue, plus inevitable errors and staff dissatisfaction, resulted in a manager-lead initiative to automate elements of the scheduling process using Microsoft Excel. The implementation of this initiative included: common coding of all 8-hour and 12-hour shifts, with each 4-hour period represented by a cell; the creation of a 6-week master schedule using the "count-if" function of Excel based on current staffing guidelines; staff time-off requests then entered by the department secretary; the head nurse, with staff input, then fine-tuned the schedule to provide even unit coverage. Outcomes of these changes included an increase in staff satisfaction, time saved by the head nurse, and staff work time saved because there was less arguing about the schedule. Ultimately, the automated self-scheduling method was expanded to the entire 700-bed hospital.

  20. Handling of computational in vitro/in vivo correlation problems by Microsoft Excel: IV. Generalized matrix analysis of linear compartment systems.

    PubMed

    Langenbucher, Frieder

    2005-01-01

    A linear system comprising n compartments is completely defined by the rate constants between any of the compartments and the initial condition in which compartment(s) the drug is present at the beginning. The generalized solution is the time profiles of drug amount in each compartment, described by polyexponential equations. Based on standard matrix operations, an Excel worksheet computes the rate constants and the coefficients, finally the full time profiles for a specified range of time values.

  1. FDG-PET Response Prediction in Pediatric Hodgkin's Lymphoma: Impact of Metabolically Defined Tumor Volumes and Individualized SUV Measurements on the Positive Predictive Value.

    PubMed

    Hussien, Amr Elsayed M; Furth, Christian; Schönberger, Stefan; Hundsdoerfer, Patrick; Steffen, Ingo G; Amthauer, Holger; Müller, Hans-Wilhelm; Hautzel, Hubertus

    2015-01-28

    In pediatric Hodgkin's lymphoma (pHL) early response-to-therapy prediction is metabolically assessed by (18)F-FDG PET carrying an excellent negative predictive value (NPV) but an impaired positive predictive value (PPV). Aim of this study was to improve the PPV while keeping the optimal NPV. A comparison of different PET data analyses was performed applying individualized standardized uptake values (SUV), PET-derived metabolic tumor volume (MTV) and the product of both parameters, termed total lesion glycolysis (TLG); One-hundred-eight PET datasets (PET1, n = 54; PET2, n = 54) of 54 children were analysed by visual and semi-quantitative means. SUVmax, SUVmean, MTV and TLG were obtained the results of both PETs and the relative change from PET1 to PET2 (Δ in %) were compared for their capability of identifying responders and non-responders using receiver operating characteristics (ROC)-curves. In consideration of individual variations in noise and contrasts levels all parameters were additionally obtained after threshold correction to lean body mass and background; All semi-quantitative SUV estimates obtained at PET2 were significantly superior to the visual PET2 analysis. However, ΔSUVmax revealed the best results (area under the curve, 0.92; p < 0.001; sensitivity 100%; specificity 85.4%; PPV 46.2%; NPV 100%; accuracy, 87.0%) but was not significantly superior to SUVmax-estimation at PET2 and ΔTLGmax. Likewise, the lean body mass and background individualization of the datasets did not impove the results of the ROC analyses; Sophisticated semi-quantitative PET measures in early response assessment of pHL patients do not perform significantly better than the previously proposed ΔSUVmax. All analytical strategies failed to improve the impaired PPV to a clinically acceptable level while preserving the excellent NPV.

  2. Simple area determination of strongly overlapping ion mobility peaks.

    PubMed

    Borovcová, Lucie; Hermannová, Martina; Pauk, Volodymyr; Šimek, Matěj; Havlíček, Vladimír; Lemr, Karel

    2017-08-15

    Coupling of ion mobility with mass spectrometry has brought new frontiers in separation and quantitation of a wide range of isobaric/isomeric compounds. Ion mobility spectrometry may separate ions possessing the identical molecular formula but having different molecular shapes. The separation space in most commercially available instruments is limited and rarely the mobility resolving power exceeds one hundred. From this perspective, new approaches allowing for extracting individual compound signals out of a more complex mixture are needed. In this work we present a new simple analytical approach based on fitting of arrival time distribution (ATD) profiles by Gaussian functions and generating of ATD functions. These ATD functions well describe even distorted ion mobility peaks of individual compounds and allow for extracting their peaks from mobilograms of mixtures. Contrary to classical integration, our approach works well with irregular overlapping peaks. Using mobilograms of standards to generate ATD functions, poorly separated compounds, e.g. isomers, with identical mass spectra representing a hard to solve task for various chemometric methods can be easily distinguished by our procedure. Alternatively ATD functions can be obtained from ATD profiles of ions unique to individual mixture components (if such ions exist) and mobilograms of standards are not required. On a set of hyaluronan-derived oligosaccharides we demonstrated excellent ATD repeatability enabling the resolution of binary mixtures, including mixtures with minor component level about 5%. Ion mobility quantitative data of isomers were confirmed by high performance liquid chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Contrast imaging in mouse embryos using high-frequency ultrasound.

    PubMed

    Denbeigh, Janet M; Nixon, Brian A; Puri, Mira C; Foster, F Stuart

    2015-03-04

    Ultrasound contrast-enhanced imaging can convey essential quantitative information regarding tissue vascularity and perfusion and, in targeted applications, facilitate the detection and measure of vascular biomarkers at the molecular level. Within the mouse embryo, this noninvasive technique may be used to uncover basic mechanisms underlying vascular development in the early mouse circulatory system and in genetic models of cardiovascular disease. The mouse embryo also presents as an excellent model for studying the adhesion of microbubbles to angiogenic targets (including vascular endothelial growth factor receptor 2 (VEGFR2) or αvβ3) and for assessing the quantitative nature of molecular ultrasound. We therefore developed a method to introduce ultrasound contrast agents into the vasculature of living, isolated embryos. This allows freedom in terms of injection control and positioning, reproducibility of the imaging plane without obstruction and motion, and simplified image analysis and quantification. Late gestational stage (embryonic day (E)16.6 and E17.5) murine embryos were isolated from the uterus, gently exteriorized from the yolk sac and microbubble contrast agents were injected into veins accessible on the chorionic surface of the placental disc. Nonlinear contrast ultrasound imaging was then employed to collect a number of basic perfusion parameters (peak enhancement, wash-in rate and time to peak) and quantify targeted microbubble binding in an endoglin mouse model. We show the successful circulation of microbubbles within living embryos and the utility of this approach in characterizing embryonic vasculature and microbubble behavior.

  4. Aspergillus infection monitored by multimodal imaging in a rat model.

    PubMed

    Pluhacek, Tomas; Petrik, Milos; Luptakova, Dominika; Benada, Oldrich; Palyzova, Andrea; Lemr, Karel; Havlicek, Vladimir

    2016-06-01

    Although myriads of experimental approaches have been published in the field of fungal infection diagnostics, interestingly, in 21st century there is no satisfactory early noninvasive tool for Aspergillus diagnostics with good sensitivity and specificity. In this work, we for the first time described the fungal burden in rat lungs by multimodal imaging approach. The Aspergillus infection was monitored by positron emission tomography and light microscopy employing modified Grocott's methenamine silver staining and eosin counterstaining. Laser ablation inductively coupled plasma mass spectrometry imaging has revealed a dramatic iron increase in fungi-affected areas, which can be presumably attributed to microbial siderophores. Quantitative elemental data were inferred from matrix-matched standards prepared from rat lungs. The iron, silver, and gold MS images collected with variable laser foci revealed that particularly silver or gold can be used as excellent elements useful for sensitively tracking the Aspergillus infection. The limit of detection was determined for both (107) Ag and (197) Au as 0.03 μg/g (5 μm laser focus). The selective incorporation of (107) Ag and (197) Au into fungal cell bodies and low background noise from both elements were confirmed by energy dispersive X-ray scattering utilizing the submicron lateral resolving power of scanning electron microscopy. The low limits of detection and quantitation of both gold and silver make ICP-MS imaging monitoring a viable alternative to standard optical evaluation used in current clinical settings. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Diabetic kidney lesions of GIPRdn transgenic mice: podocyte hypertrophy and thickening of the GBM precede glomerular hypertrophy and glomerulosclerosis.

    PubMed

    Herbach, Nadja; Schairer, Irene; Blutke, Andreas; Kautz, Sabine; Siebert, Angela; Göke, Burkhard; Wolf, Eckhard; Wanke, Ruediger

    2009-04-01

    Diabetic nephropathy is the leading cause of end-stage renal disease and the largest contributor to the total cost of diabetes care. Rodent models are excellent tools to gain more insight into the pathogenesis of diabetic nephropathy. In the present study, we characterize the age-related sequence of diabetes-associated kidney lesions in GIPR(dn) transgenic mice, a novel mouse model of early-onset diabetes mellitus. Clinical-chemical analyses as well as qualitative and quantitative morphological analyses of the kidneys of GIPR(dn) transgenic animals and nontransgenic littermate controls were performed at 3, 8, 20, and 28 wk of age. Early renal changes of transgenic mice consisted of podocyte hypertrophy, reduced numerical volume density of podocytes in glomeruli, and homogenous thickening of the glomerular basement membrane, followed by renal and glomerular hypertrophy as well as mesangial expansion and matrix accumulation. At 28 wk of age, glomerular damage was most prominent, including advanced glomerulosclerosis, tubulointerstitial lesions, and proteinuria. Real-time PCR demonstrated increased glomerular expression of Col4a1, Fn1, and Tgfb1. Immunohistochemistry revealed increased mesangial deposition of collagen type IV, fibronectin, and laminin. The present study shows that GIPR(dn) transgenic mice exhibit renal changes that closely resemble diabetes-associated kidney alterations in humans. Data particularly from male transgenic mice indicate that podocyte hypertrophy is directly linked to hyperglycemia, without the influence of mechanical stress. GIPR(dn) transgenic mice are considered an excellent new tool to study the mechanisms involved in onset and progression of diabetic nephropathy.

  6. MR imaging of iliofemoral peripheral vascular calcifications using proton density-weighted, in-phase three-dimensional stack-of-stars gradient echo.

    PubMed

    Ferreira Botelho, Marcos P; Koktzoglou, Ioannis; Collins, Jeremy D; Giri, Shivraman; Carr, James C; Gupta, NavYash; Edelman, Robert R

    2017-06-01

    The presence of vascular calcifications helps to determine percutaneous access for interventional vascular procedures and has prognostic value for future cardiovascular events. Unlike CT, standard MRI techniques are insensitive to vascular calcifications. In this prospective study, we tested a proton density-weighted, in-phase (PDIP) three-dimensional (3D) stack-of-stars gradient-echo pulse sequence with approximately 1 mm 3 isotropic spatial resolution at 1.5 Tesla (T) and 3T to detect iliofemoral peripheral vascular calcifications and correlated MR-determined lesion volumes with CT angiography (CTA). The study was approved by the Institutional Review Board. The prototype PDIP stack-of-stars pulse sequence was applied in 12 patients with iliofemoral peripheral vascular calcifications who had undergone CTA. Vascular calcifications were well visualized in all subjects, excluding segments near prostheses or stents. The location, size, and shape of the calcifications were similar to CTA. Quantitative analysis showed excellent correlation (r 2  = 0.84; P < 0.0001) between MR- and CT-based measures of calcification volume. In one subject in whom three pulse sequences were compared, PDIP stack-of-stars outperformed cartesian 3D gradient-echo and point-wise encoding time reduction with radial acquisition (PETRA). In this pilot study, a PDIP 3D stack-of-stars gradient-echo pulse sequence with high spatial resolution provided excellent image quality and accurately depicted the location and volume of iliofemoral vascular calcifications. Magn Reson Med 77:2146-2152, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  7. Highly Sensitive and Automated Surface Enhanced Raman Scattering-based Immunoassay for H5N1 Detection with Digital Microfluidics.

    PubMed

    Wang, Yang; Ruan, Qingyu; Lei, Zhi-Chao; Lin, Shui-Chao; Zhu, Zhi; Zhou, Leiji; Yang, Chaoyong

    2018-04-17

    Digital microfluidics (DMF) is a powerful platform for a broad range of applications, especially immunoassays having multiple steps, due to the advantages of low reagent consumption and high automatization. Surface enhanced Raman scattering (SERS) has been proven as an attractive method for highly sensitive and multiplex detection, because of its remarkable signal amplification and excellent spatial resolution. Here we propose a SERS-based immunoassay with DMF for rapid, automated, and sensitive detection of disease biomarkers. SERS tags labeled with Raman reporter 4-mercaptobenzoic acid (4-MBA) were synthesized with a core@shell nanostructure and showed strong signals, good uniformity, and high stability. A sandwich immunoassay was designed, in which magnetic beads coated with antibodies were used as solid support to capture antigens from samples to form a beads-antibody-antigen immunocomplex. By labeling the immunocomplex with a detection antibody-functionalized SERS tag, antigen can be sensitively detected through the strong SERS signal. The automation capability of DMF can greatly simplify the assay procedure while reducing the risk of exposure to hazardous samples. Quantitative detection of avian influenza virus H5N1 in buffer and human serum was implemented to demonstrate the utility of the DMF-SERS method. The DMF-SERS method shows excellent sensitivity (LOD of 74 pg/mL) and selectivity for H5N1 detection with less assay time (<1 h) and lower reagent consumption (∼30 μL) compared to the standard ELISA method. Therefore, this DMF-SERS method holds great potentials for automated and sensitive detection of a variety of infectious diseases.

  8. Graphite paper-based bipolar electrode electrochemiluminescence sensing platform.

    PubMed

    Zhang, Xin; Ding, Shou-Nian

    2017-08-15

    In this work, aiming at the construction of a disposable, wireless, low-cost and sensitive system for bioassay, we report a closed bipolar electrode electrochemiluminescence (BPE-ECL) sensing platform based on graphite paper as BPE for the first time. Graphite paper is qualified as BPE due to its unique properties such as excellent electrical conductivity, uniform composition and ease of use. This simple BPE-ECL device was applied to the quantitative analysis of oxidant (H 2 O 2 ) and biomarker (CEA) respectively, according to the principle of BPE sensing-charge balance. For the H 2 O 2 analysis, Pt NPs were electrodeposited onto the cathode through a bipolar electrodeposition approach to promote the sensing performance. As a result, this BPE-ECL device exhibited a wide linear range of 0.001-15mM with a low detection limit of 0.5µM (S/N=3) for H 2 O 2 determination. For the determination of CEA, chitosan-multi-walled carbon nanotubes (CS-MWCNTs) were employed to supply a hydrophilic interface for immobilizing primary antibody (Ab 1 ); and Au@Pt nanostructures were conjugated with secondary antibody (Ab 2 ) as catalysts for H 2 O 2 reduction. Under the optimal conditions, the BPE-ECL immunodevice showed a wide linear range of 0.01-60ngmL -1 with a detection limit of 5.0pgmL -1 for CEA. Furthermore, it also displayed satisfactory selectivity, excellent stability and good reproducibility. The developed method opened a new avenue to clinical bioassay. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. International ranking systems for universities and institutions: a critical appraisal

    PubMed Central

    Ioannidis, John PA; Patsopoulos, Nikolaos A; Kavvoura, Fotini K; Tatsioni, Athina; Evangelou, Evangelos; Kouri, Ioanna; Contopoulos-Ioannidis, Despina G; Liberopoulos, George

    2007-01-01

    Background Ranking of universities and institutions has attracted wide attention recently. Several systems have been proposed that attempt to rank academic institutions worldwide. Methods We review the two most publicly visible ranking systems, the Shanghai Jiao Tong University 'Academic Ranking of World Universities' and the Times Higher Education Supplement 'World University Rankings' and also briefly review other ranking systems that use different criteria. We assess the construct validity for educational and research excellence and the measurement validity of each of the proposed ranking criteria, and try to identify generic challenges in international ranking of universities and institutions. Results None of the reviewed criteria for international ranking seems to have very good construct validity for both educational and research excellence, and most don't have very good construct validity even for just one of these two aspects of excellence. Measurement error for many items is also considerable or is not possible to determine due to lack of publication of the relevant data and methodology details. The concordance between the 2006 rankings by Shanghai and Times is modest at best, with only 133 universities shared in their top 200 lists. The examination of the existing international ranking systems suggests that generic challenges include adjustment for institutional size, definition of institutions, implications of average measurements of excellence versus measurements of extremes, adjustments for scientific field, time frame of measurement and allocation of credit for excellence. Conclusion Naïve lists of international institutional rankings that do not address these fundamental challenges with transparent methods are misleading and should be abandoned. We make some suggestions on how focused and standardized evaluations of excellence could be improved and placed in proper context. PMID:17961208

  10. LBflow: An extensible lattice Boltzmann framework for the simulation of geophysical flows. Part II: usage and validation

    NASA Astrophysics Data System (ADS)

    Llewellin, E. W.

    2010-02-01

    LBflow is a flexible, extensible implementation of the lattice Boltzmann method, developed with geophysical applications in mind. The theoretical basis for LBflow, and its implementation, are presented in the companion paper, 'Part I'. This article covers the practical usage of LBflow and presents guidelines for obtaining optimal results from available computing power. The relationships among simulation resolution, accuracy, runtime and memory requirements are investigated in detail. Particular attention is paid to the origin, quantification and minimization of errors. LBflow is validated against analytical, numerical and experimental results for a range of three-dimensional flow geometries. The fluid conductance of prismatic pipes with various cross sections is calculated with LBflow and found to be in excellent agreement with published results. Simulated flow along sinusoidally constricted pipes gives good agreement with experimental data for a wide range of Reynolds number. The permeability of packs of spheres is determined and shown to be in excellent agreement with analytical results. The accuracy of internal flow patterns within the investigated geometries is also in excellent quantitative agreement with published data. The development of vortices within a sinusoidally constricted pipe with increasing Reynolds number is shown, demonstrating the insight that LBflow can offer as a 'virtual laboratory' for fluid flow.

  11. [Application of three compartment model and response surface model to clinical anesthesia using Microsoft Excel].

    PubMed

    Abe, Eiji; Abe, Mari

    2011-08-01

    With the spread of total intravenous anesthesia, clinical pharmacology has become more important. We report Microsoft Excel file applying three compartment model and response surface model to clinical anesthesia. On the Microsoft Excel sheet, propofol, remifentanil and fentanyl effect-site concentrations are predicted (three compartment model), and probabilities of no response to prodding, shaking, surrogates of painful stimuli and laryngoscopy are calculated using predicted effect-site drug concentration. Time-dependent changes in these calculated values are shown graphically. Recent development in anesthetic drug interaction studies are remarkable, and its application to clinical anesthesia with this Excel file is simple and helpful for clinical anesthesia.

  12. Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.

    PubMed

    Balogh, A L; Petak, F; Fodor, G H; Tolnai, J; Csorba, Z; Babik, B

    2016-07-01

    Capnography may provide useful non-invasive bedside information concerning heterogeneity in lung ventilation, ventilation-perfusion mismatching and metabolic status. Although the capnogram may be recorded by mainstream and sidestream techniques, the capnogram indices furnished by these approaches have not previously been compared systematically. Simultaneous mainstream and sidestream time and volumetric capnography was performed in anaesthetized, mechanically ventilated patients undergoing elective heart surgery. Time capnography was used to assess the phase II (SII,T) and III slopes (SIII,T). The volumetric method was applied to estimate phase II (SII,V) and III slopes (SIII,V), together with the dead space values according to the Fowler (VDF), Bohr (VDB), and Enghoff (VDE) methods and the volume of CO2 eliminated per breath ([Formula: see text]). The partial pressure of end-tidal CO2 ([Formula: see text]) was registered. Excellent correlation and good agreement were observed in SIII,T measured by the mainstream and sidestream techniques [ratio=1.05 (sem 0.16), R(2)=0.92, P<0.0001]. Although the sidestream technique significantly underestimated [Formula: see text] and overestimated SIII,V [1.32 (0.28), R(2)=0.93, P<0.0001], VDF, VDB, and VDE, the agreement between the mainstream and sidestream techniques in the difference between VDE and VDB, reflecting the intrapulmonary shunt, was excellent [0.97 (0.004), R(2)=0.92, P<0.0001]. The [Formula: see text] exhibited good correlation and mild differences between the mainstream and sidestream approaches [0.025 (0.005) kPa]. Sidestream capnography provides adequate quantitative bedside information about uneven alveolar emptying and ventilation-perfusion mismatching, because it allows reliable assessments of the phase III slope, [Formula: see text] and intrapulmonary shunt. Reliable measurement of volumetric parameters (phase II slope, dead spaces, and eliminated CO2 volumes) requires the application of a mainstream device. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques

    PubMed Central

    Balogh, A. L.; Petak, F.; Fodor, G. H.; Tolnai, J.; Csorba, Z.; Babik, B.

    2016-01-01

    Background Capnography may provide useful non-invasive bedside information concerning heterogeneity in lung ventilation, ventilation–perfusion mismatching and metabolic status. Although the capnogram may be recorded by mainstream and sidestream techniques, the capnogram indices furnished by these approaches have not previously been compared systematically. Methods Simultaneous mainstream and sidestream time and volumetric capnography was performed in anaesthetized, mechanically ventilated patients undergoing elective heart surgery. Time capnography was used to assess the phase II (SII,T) and III slopes (SIII,T). The volumetric method was applied to estimate phase II (SII,V) and III slopes (SIII,V), together with the dead space values according to the Fowler (VDF), Bohr (VDB), and Enghoff (VDE) methods and the volume of CO2 eliminated per breath (VCO2). The partial pressure of end-tidal CO2 (PETCO2) was registered. Results Excellent correlation and good agreement were observed in SIII,T measured by the mainstream and sidestream techniques [ratio=1.05 (sem 0.16), R2=0.92, P<0.0001]. Although the sidestream technique significantly underestimated VCO2 and overestimated SIII,V [1.32 (0.28), R2=0.93, P<0.0001], VDF, VDB, and VDE, the agreement between the mainstream and sidestream techniques in the difference between VDE and VDB, reflecting the intrapulmonary shunt, was excellent [0.97 (0.004), R2=0.92, P<0.0001]. The PETCO2 exhibited good correlation and mild differences between the mainstream and sidestream approaches [0.025 (0.005) kPa]. Conclusions Sidestream capnography provides adequate quantitative bedside information about uneven alveolar emptying and ventilation–perfusion mismatching, because it allows reliable assessments of the phase III slope, PETCO2 and intrapulmonary shunt. Reliable measurement of volumetric parameters (phase II slope, dead spaces, and eliminated CO2 volumes) requires the application of a mainstream device. PMID:27317710

  14. Robust high-resolution quantification of time signals encoded by in vivo magnetic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Belkić, Dževad; Belkić, Karen

    2018-01-01

    This paper on molecular imaging emphasizes improving specificity of magnetic resonance spectroscopy (MRS) for early cancer diagnostics by high-resolution data analysis. Sensitivity of magnetic resonance imaging (MRI) is excellent, but specificity is insufficient. Specificity is improved with MRS by going beyond morphology to assess the biochemical content of tissue. This is contingent upon accurate data quantification of diagnostically relevant biomolecules. Quantification is spectral analysis which reconstructs chemical shifts, amplitudes and relaxation times of metabolites. Chemical shifts inform on electronic shielding of resonating nuclei bound to different molecular compounds. Oscillation amplitudes in time signals retrieve the abundance of MR sensitive nuclei whose number is proportional to metabolite concentrations. Transverse relaxation times, the reciprocal of decay probabilities of resonances, arise from spin-spin coupling and reflect local field inhomogeneities. In MRS single voxels are used. For volumetric coverage, multi-voxels are employed within a hybrid of MRS and MRI called magnetic resonance spectroscopic imaging (MRSI). Common to MRS and MRSI is encoding of time signals and subsequent spectral analysis. Encoded data do not provide direct clinical information. Spectral analysis of time signals can yield the quantitative information, of which metabolite concentrations are the most clinically important. This information is equivocal with standard data analysis through the non-parametric, low-resolution fast Fourier transform and post-processing via fitting. By applying the fast Padé transform (FPT) with high-resolution, noise suppression and exact quantification via quantum mechanical signal processing, advances are made, presented herein, focusing on four areas of critical public health importance: brain, prostate, breast and ovarian cancers.

  15. The Lumipulse G HBsAg-Quant assay for screening and quantification of the hepatitis B surface antigen.

    PubMed

    Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai

    2016-02-01

    Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, P<0.0001), while minor quantitative biases existed. The Lumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Ultra-high performance supercritical fluid chromatography of lignin-derived phenols from alkaline cupric oxide oxidation.

    PubMed

    Sun, Mingzhe; Lidén, Gunnar; Sandahl, Margareta; Turner, Charlotta

    2016-08-01

    Traditional chromatographic methods for the analysis of lignin-derived phenolic compounds in environmental samples are generally time consuming. In this work, an ultra-high performance supercritical fluid chromatography method with a diode array detector for the analysis of major lignin-derived phenolic compounds produced by alkaline cupric oxide oxidation was developed. In an analysis of a collection of 11 representative monomeric lignin phenolic compounds, all compounds were clearly separated within 6 min with excellent peak shapes, with a limit of detection of 0.5-2.5 μM, a limit of quantification of 2.5-5.0 μM, and a dynamic range of 5.0-2.0 mM (R(2) > 0.997). The new ultra-high performance supercritical fluid chromatography method was also applied for the qualitative and quantitative analysis of lignin-derived phenolic compounds obtained upon alkaline cupric oxide oxidation of a commercial humic acid. Ten out of the previous eleven model compounds could be quantified in the oxidized humic acid sample. The high separation power and short analysis time obtained demonstrate for the first time that supercritical fluid chromatography is a fast and reliable technique for the analysis of lignin-derived phenols in complex environmental samples. © 2016 The Authors, Journal of Separation Science Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Capillary Electrophoresis-Mass Spectrometry for the Analysis of Heparin Oligosaccharides and Low Molecular Weight Heparin.

    PubMed

    Sun, Xiaojun; Lin, Lei; Liu, Xinyue; Zhang, Fuming; Chi, Lianli; Xia, Qiangwei; Linhardt, Robert J

    2016-02-02

    Heparins, highly sulfated, linear polysaccharides also known as glycosaminoglycans, are among the most challenging biopolymers to analyze. Hyphenated techniques in conjunction with mass spectrometry (MS) offer rapid analysis of complex glycosaminoglycan mixtures, providing detailed structural and quantitative data. Previous analytical approaches have often relied on liquid chromatography (LC)-MS, and some have limitations including long separation times, low resolution of oligosaccharide mixtures, incompatibility of eluents, and often require oligosaccharide derivatization. This study examines the analysis of glycosaminoglycan oligosaccharides using a novel electrokinetic pump-based capillary electrophoresis (CE)-MS interface. CE separation and electrospray were optimized using a volatile ammonium bicarbonate electrolyte and a methanol-formic acid sheath fluid. The online analyses of highly sulfated heparin oligosaccharides, ranging from disaccharides to low molecular weight heparins, were performed within a 10 min time frame, offering an opportunity for higher-throughput analysis. Disaccharide compositional analysis as well as top-down analysis of low molecular weight heparin was demonstrated. Using normal polarity CE separation and positive-ion electrospray ionization MS, excellent run-to-run reproducibility (relative standard deviation of 3.6-5.1% for peak area and 0.2-0.4% for peak migration time) and sensitivity (limit of quantification of 2.0-5.9 ng/mL and limit of detection of 0.6-1.8 ng/mL) could be achieved.

  18. Investigation of water imbibition in porous stone by thermal neutron radiography

    NASA Astrophysics Data System (ADS)

    Hassanein, R.; Meyer, H. O.; Carminati, A.; Estermann, M.; Lehmann, E.; Vontobel, P.

    2006-10-01

    The understanding and modelling of the process of water imbibition is important for various applications of physics (e.g. building or soil physics). To measure the spatial distribution of the water content at arbitrary times is not trivial. Neutron radiography provides an appropriate tool for such investigations with excellent time and spatial resolution. Because of the high sensitivity to hydrogen, even small amounts of water in a porous structure can be detected in samples with dimensions up to 40 cm. Three different porous stones found in Indiana, USA, have been investigated (Mansfield sandstone, Salem limestone and Hindustan whetstone). The imbibition of deionized water and a NaCl solution in up- and downwards directions has been tracked during several hours and radiographed at regular intervals. A correction method to reduce the disturbing effects due to neutron scattering is applied. This allows a quantitative evaluation of the water content in addition to the visualization of the water distribution. The results agree well with theoretical models describing water infiltration and reproduce the water content with a pixel resolution of 272 µm in time steps of 1 min. The comparison with the radiographed structure of the dry stone explains variations in the conduction or retention of the water, respectively. The experimental and correction procedures described here can be applied to other porous media and their uptake and loss of fluids.

  19. Solid-phase extraction with the metal-organic framework MIL-101(Cr) combined with direct analysis in real time mass spectrometry for the fast analysis of triazine herbicides.

    PubMed

    Li, Xianjiang; Xing, Jiawei; Chang, Cuilan; Wang, Xin; Bai, Yu; Yan, Xiuping; Liu, Huwei

    2014-06-01

    MIL-101(Cr) is an excellent metal-organic framework with high surface area and nanoscale cavities, making it promising in solid-phase extraction. Herein, we used MIL-101(Cr) as a solid-phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART-MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL-101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1∼0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5∼1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85∼110%. These results showed that solid-phase extraction with metal-organic frameworks is an efficient sample preparation approach for DART-MS analysis and could find more applications in environmental analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development and validation of an ultra-performance convergence chromatography method for the quality control of Angelica gigas Nakai.

    PubMed

    Kim, Hyo Seon; Chun, Jin Mi; Kwon, Bo-In; Lee, A-Reum; Kim, Ho Kyoung; Lee, A Yeong

    2016-10-01

    Ultra-performance convergence chromatography, which integrates the advantages of supercritical fluid chromatography and ultra high performance liquid chromatography technologies, is an environmentally friendly analytical method that uses dramatically reduced amounts of organic solvents. An ultra-performance convergence chromatography method was developed and validated for the quantification of decursinol angelate and decursin in Angelica gigas using a CSH Fluoro-Phenyl column (2.1 mm × 150 mm, 1.7 μm) with a run time of 4 min. The method had an improved resolution and a shorter analysis time in comparison to the conventional high-performance liquid chromatography method. This method was validated in terms of linearity, precision, and accuracy. The limits of detection were 0.005 and 0.004 μg/mL for decursinol angelate and decursin, respectively, while the limits of quantitation were 0.014 and 0.012 μg/mL, respectively. The two components showed good regression (correlation coefficient (r 2 ) > 0.999), excellent precision (RSD < 2.28%), and acceptable recoveries (99.75-102.62%). The proposed method can be used to efficiently separate, characterize, and quantify decursinol angelate and decursin in Angelica gigas and its related medicinal materials or preparations, with the advantages of a shorter analysis time, greater sensitivity, and better environmental compatibility. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Carbon quantum dots-based recyclable real-time fluorescence assay for alkaline phosphatase with adenosine triphosphate as substrate.

    PubMed

    Qian, Zhaosheng; Chai, Lujing; Tang, Cong; Huang, Yuanyuan; Chen, Jianrong; Feng, Hui

    2015-03-03

    A convenient, reliable, and highly sensitive real-time assay for alkaline phosphatase (ALP) activity in the continuous and recyclable way is established on the basis of aggregation and disaggregation of carbon quantum dots (CQDs) through the competitive assay approach. CQDs and adenosine triphosphate (ATP) were used as the fluorescent indicator and substrate for ALP activity assessment, respectively. Richness of carboxyl groups on the surface of CQDs enables their severe aggregation triggered by cerium ions, which results in effective fluorescence quenching. Under the catalytic hydrolysis of ALP, ATP can be rapidly transformed to phosphate ions. Stronger affinity of phosphate ions to cerium ions than carboxyl groups is taken advantage of to achieve fluorescence recovery induced by redispersion of CQDs in the presence of ALP and ATP. Quantitative evaluation of ALP activity in a broad range from 4.6 to 383.3 U/L with the detection limit of 1.4 U/L can be realized in this way, which endows the assay with high enough sensitivity for practical detection in human serum. The assay can be used in a recyclable way for more than three times since the generated product CePO4 as a precipitate can be easily removed from the standard assay system. This strategy broadens the sensing application of fluorescent CQDs with excellent biocompatibility and provides an example based on disaggregation in optical probe development.

  2. An excellent navigation system and experience in craniomaxillofacial navigation surgery: a double-center study

    PubMed Central

    Dai, Jiewen; Wu, Jinyang; Wang, Xudong; Yang, Xudong; Wu, Yunong; Xu, Bing; Shi, Jun; Yu, Hongbo; Cai, Min; Zhang, Wenbin; Zhang, Lei; Sun, Hao; Shen, Guofang; Zhang, Shilei

    2016-01-01

    Numerous problems regarding craniomaxillofacial navigation surgery are not well understood. In this study, we performed a double-center clinical study to quantitatively evaluate the characteristics of our navigation system and experience in craniomaxillofacial navigation surgery. Fifty-six patients with craniomaxillofacial disease were included and randomly divided into experimental (using our AccuNavi-A system) and control (using Strker system) groups to compare the surgical effects. The results revealed that the average pre-operative planning time was 32.32 mins vs 29.74 mins between the experimental and control group, respectively (p > 0.05). The average operative time was 295.61 mins vs 233.56 mins (p > 0.05). The point registration orientation accuracy was 0.83 mm vs 0.92 mm. The maximal average preoperative navigation orientation accuracy was 1.03 mm vs 1.17 mm. The maximal average persistent navigation orientation accuracy was 1.15 mm vs 0.09 mm. The maximal average navigation orientation accuracy after registration recovery was 1.15 mm vs 1.39 mm between the experimental and control group. All patients healed, and their function and profile improved. These findings demonstrate that although surgeons should consider the patients’ time and monetary costs, our qualified navigation surgery system and experience could offer an accurate guide during a variety of craniomaxillofacial surgeries. PMID:27305855

  3. A practical guide to value of information analysis.

    PubMed

    Wilson, Edward C F

    2015-02-01

    Value of information analysis is a quantitative method to estimate the return on investment in proposed research projects. It can be used in a number of ways. Funders of research may find it useful to rank projects in terms of the expected return on investment from a variety of competing projects. Alternatively, trialists can use the principles to identify the efficient sample size of a proposed study as an alternative to traditional power calculations, and finally, a value of information analysis can be conducted alongside an economic evaluation as a quantitative adjunct to the 'future research' or 'next steps' section of a study write up. The purpose of this paper is to present a brief introduction to the methods, a step-by-step guide to calculation and a discussion of issues that arise in their application to healthcare decision making. Worked examples are provided in the accompanying online appendices as Microsoft Excel spreadsheets.

  4. Development of end-selective functionalized carbon nanotubes for biomedical applications

    NASA Astrophysics Data System (ADS)

    Lee, Seung Ho; Kim, Wan Sun; Lee, Ha Rim; Park, Kyu Chang; Lee, Chang Hoon; Park, Hun Kuk; Kim, Kyung Sook

    2015-12-01

    Carbon nanotube (CNT) is a type of carbon allotrope with excellent physical and electrical properties, including high thermal conductivity, mechanical strength, and thermal stability. Therefore, applications of CNT have been considered for a variety of fields, including biosensors, molecular electronics, X-ray, and fuel cells. However, the application of CNT to biomedicine is limited because this material is cytotoxic and inhomogeneous. In particular, the irregularity in the structural properties of paste or bundle-type CNTs causes an uncontrolled modification in biomolecules. Therefore, using CNT as biosensors to obtain quantitative analyses is difficult. In this study, we developed a new method to perform end-selective functionalization of CNT in order to enable quantitative analysis for biomedical applications. The process was as follows: (1) etching the tip of vertically-aligned CNTs under optimum conditions, (2) oxidation of exposed CNTs, and (3) end-selective linkage of functionalized CNTs with biomolecules (dsDNA).

  5. Quantitative Accelerated Life Testing of MEMS Accelerometers

    PubMed Central

    Bâzu, Marius; Gălăţeanu, Lucian; Ilian, Virgil Emil; Loicq, Jerome; Habraken, Serge; Collette, Jean-Paul

    2007-01-01

    Quantitative Accelerated Life Testing (QALT) is a solution for assessing the reliability of Micro Electro Mechanical Systems (MEMS). A procedure for QALT is shown in this paper and an attempt to assess the reliability level for a batch of MEMS accelerometers is reported. The testing plan is application-driven and contains combined tests: thermal (high temperature) and mechanical stress. Two variants of mechanical stress are used: vibration (at a fixed frequency) and tilting. Original equipment for testing at tilting and high temperature is used. Tilting is appropriate as application-driven stress, because the tilt movement is a natural environment for devices used for automotive and aerospace applications. Also, tilting is used by MEMS accelerometers for anti-theft systems. The test results demonstrated the excellent reliability of the studied devices, the failure rate in the “worst case” being smaller than 10-7h-1. PMID:28903265

  6. Perfluorocarbon Nanoparticles for Physiological and Molecular Imaging and Therapy

    PubMed Central

    Chen, Junjie; Pan, Hua; Lanza, Gregory M.; Wickline, Samuel A.

    2014-01-01

    Herein we review the use of non-nephrotoxic perfluorocarbon nanoparticles (PFC NP) for noninvasive detection and therapy of kidney diseases, and provide a synopsis of other related literature pertinent to anticipated clinical application. Recent reports indicate that PFC NP allow quantitative mapping of kidney perfusion, and oxygenation after ischemia-reperfusion injury with the use of a novel multi-nuclear 1H/19F magnetic resonance imaging (MRI) approach,. Furthermore, when conjugated with targeting ligands, the functionalized PFC NP offer unique and quantitative capabilities for imaging inflammation in the kidney of atherosclerotic ApoE-null mice. Additionally, PFC NP can facilitate drug delivery for treatment of inflammation, thrombosis, and angiogenesis in selected conditions that are comorbidities for to kidney failure. The excellent safety profile of PFC NP with respect to kidney injury positions these nanomedicine approaches as promising diagnostic and therapeutic candidates for treating and following acute and chronic kidney diseases. PMID:24206599

  7. Determination of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution by reaction-based headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan

    2018-04-01

    We report on a headspace gas chromatographic method for determining the content of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution. It was based on quantitatively converting 3-chloro-1,2-propanediol to formaldehyde by periodate oxidation in a closed headspace sample vial at a room temperature for 10 min, and then to methanol by borohydride reduction at 90°C for 40 min followed by the headspace gas chromatographic measurement. The results showed that the present method has an excellent measurement precision (relative standard deviation < 2.60%) and accuracy (recoveries from 96.4-102%) in 3-chloro-1,2-propanediol analysis. The limit of quantitation was 0.031 mg/mL. It is simple and suitable for determining the 3-chloro-1,2-propanediol content in polyamideamine epichlorohydrin resin solution. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Investigation of the Thermomechanical Response of Shape Memory Alloy Hybrid Composite Beams

    NASA Technical Reports Server (NTRS)

    Davis, Brian A.

    2005-01-01

    Previous work at NASA Langley Research Center (LaRC) involved fabrication and testing of composite beams with embedded, pre-strained shape memory alloy (SMA) ribbons. That study also provided comparison of experimental results with numerical predictions from a research code making use of a new thermoelastic model for shape memory alloy hybrid composite (SMAHC) structures. The previous work showed qualitative validation of the numerical model. However, deficiencies in the experimental-numerical correlation were noted and hypotheses for the discrepancies were given for further investigation. The goal of this work is to refine the experimental measurement and numerical modeling approaches in order to better understand the discrepancies, improve the correlation between prediction and measurement, and provide rigorous quantitative validation of the numerical model. Thermal buckling, post-buckling, and random responses to thermal and inertial (base acceleration) loads are studied. Excellent agreement is achieved between the predicted and measured results, thereby quantitatively validating the numerical tool.

  9. A quantitative approach to evaluating caring in nursing simulation.

    PubMed

    Eggenberger, Terry L; Keller, Kathryn B; Chase, Susan K; Payne, Linda

    2012-01-01

    This study was designed to test a quantitative method of measuring caring in the simulated environment. Since competency in caring is central to nursing practice, ways of including caring concepts in designing scenarios and in evaluation of performance need to be developed. Coates' Caring Efficacy scales were adapted for simulation and named the Caring Efficacy Scale-Simulation Student Version (CES-SSV) and Caring Efficacy Scale-Simulation Faculty Version (CES-SFV). A correlational study was designed to compare student self-ratings with faculty ratings on caring efficacy during an adult acute simulation experience with traditional and accelerated baccalaureate students in a nursing program grounded in caring theory. Student self-ratings were significantly correlated with objective ratings (r = 0.345, 0.356). Both the CES-SSV and the CES-SFV were found to have excellent internal consistency and significantly correlated interrater reliability. They were useful in measuring caring in the simulated learning environment.

  10. (/sup 3/H)Batrachotoxinin A 20 alpha-benzoate binding to voltage-sensitive sodium channels: a rapid and quantitative assay for local anesthetic activity in a variety of drugs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNeal, E.T.; Lewandowski, G.A.; Daly, J.W.

    1985-03-01

    (/sup 3/H)Batrachotoxinin A benzoate ((/sup 3/H)BTX-B) binds with high affinity to sites on voltage-dependent sodium channels in a vesicular preparation from guinea pig cerebral cortex. In this preparation, local anesthetics competitively antagonize the binding of (/sup 3/H)BTX-B. The potencies of some 40 classical local anesthetics and a variety of catecholamine, histamine, serotonin, adenosine, GABA, glycine, acetylcholine, and calcium antagonists, tranquilizers, antidepressants, barbiturates, anticonvulsants, steroids, vasodilators, antiinflammatories, anticoagulants, analgesics, and other agents have been determined. An excellent correlation with the known local anesthetic activity of many of these agents indicate that antagonism of binding of (/sup 3/H)BTX-B binding provides a rapid,more » quantitative, and facile method for the screening and investigation of local anesthetic activity.« less

  11. Determination of the rCBF in the Amygdala and Rhinal Cortex Using a FAIR-TrueFISP Sequence

    PubMed Central

    Martirosian, Petros; Klose, Uwe; Nägele, Thomas; Schick, Fritz; Ernemann, Ulrike

    2011-01-01

    Objective Brain perfusion can be assessed non-invasively by modern arterial spin labeling MRI. The FAIR (flow-sensitive alternating inversion recovery)-TrueFISP (true fast imaging in steady precession) technique was applied for regional assessment of cerebral blood flow in brain areas close to the skull base, since this approach provides low sensitivity to magnetic susceptibility effects. The investigation of the rhinal cortex and the amygdala is a potentially important feature for the diagnosis and research on dementia in its early stages. Materials and Methods Twenty-three subjects with no structural or psychological impairment were investigated. FAIR-True-FISP quantitative perfusion data were evaluated in the amygdala on both sides and in the pons. A preparation of the radiofrequency FOCI (frequency offset corrected inversion) pulse was used for slice selective inversion. After a time delay of 1.2 sec, data acquisition began. Imaging slice thickness was 5 mm and inversion slab thickness for slice selective inversion was 12.5 mm. Image matrix size for perfusion images was 64 × 64 with a field of view of 256 × 256 mm, resulting in a spatial resolution of 4 × 4 × 5 mm. Repetition time was 4.8 ms; echo time was 2.4 ms. Acquisition time for the 50 sets of FAIR images was 6:56 min. Data were compared with perfusion data from the literature. Results Perfusion values in the right amygdala, left amygdala and pons were 65.2 (± 18.2) mL/100 g/minute, 64.6 (± 21.0) mL/100 g/minute, and 74.4 (± 19.3) mL/100 g/minute, respectively. These values were higher than formerly published data using continuous arterial spin labeling but similar to 15O-PET (oxygen-15 positron emission tomography) data. Conclusion The FAIR-TrueFISP approach is feasible for the quantitative assessment of perfusion in the amygdala. Data are comparable with formerly published data from the literature. The applied technique provided excellent image quality, even for brain regions located at the skull base in the vicinity of marked susceptibility steps. PMID:21927556

  12. A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

    PubMed

    Tudorica, Luminita A; Oh, Karen Y; Roy, Nicole; Kettler, Mark D; Chen, Yiyi; Hemmingson, Stephanie L; Afzal, Aneela; Grinstead, John W; Laub, Gerhard; Li, Xin; Huang, Wei

    2012-11-01

    Three dimensional bilateral imaging is the standard for most clinical breast dynamic contrast-enhanced (DCE) MRI protocols. Because of high spatial resolution (sRes) requirement, the typical 1-2 min temporal resolution (tRes) afforded by a conventional full-k-space-sampling gradient echo (GRE) sequence precludes meaningful and accurate pharmacokinetic analysis of DCE time-course data. The commercially available, GRE-based, k-space undersampling and data sharing TWIST (time-resolved angiography with stochastic trajectories) sequence was used in this study to perform DCE-MRI exams on thirty one patients (with 36 suspicious breast lesions) before their biopsies. The TWIST DCE-MRI was immediately followed by a single-frame conventional GRE acquisition. Blinded from each other, three radiologist readers assessed agreements in multiple lesion morphology categories between the last set of TWIST DCE images and the conventional GRE images. Fleiss' κ test was used to evaluate inter-reader agreement. The TWIST DCE time-course data were subjected to quantitative pharmacokinetic analyses. With a four-channel phased-array breast coil, the TWIST sequence produced DCE images with 20 s or less tRes and ~ 1.0×1.0×1.4 mm(3) sRes. There were no significant differences in signal-to-noise (P=.45) and contrast-to-noise (P=.51) ratios between the TWIST and conventional GRE images. The agreements in morphology evaluations between the two image sets were excellent with the intra-reader agreement ranging from 79% for mass margin to 100% for mammographic density and the inter-reader κ value ranging from 0.54 (P<.0001) for lesion size to 1.00 (P<.0001) for background parenchymal enhancement. Quantitative analyses of the DCE time-course data provided higher breast cancer diagnostic accuracy (91% specificity at 100% sensitivity) than the current clinical practice of morphology and qualitative kinetics assessments. The TWIST sequence may be used in clinical settings to acquire high spatiotemporal resolution breast DCE-MRI images for both precise lesion morphology characterization and accurate pharmacokinetic analysis. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Clinical-Radiological Parameters Improve the Prediction of the Thrombolysis Time Window by Both MRI Signal Intensities and DWI-FLAIR Mismatch.

    PubMed

    Madai, Vince Istvan; Wood, Carla N; Galinovic, Ivana; Grittner, Ulrike; Piper, Sophie K; Revankar, Gajanan S; Martin, Steve Z; Zaro-Weber, Olivier; Moeller-Hartmann, Walter; von Samson-Himmelstjerna, Federico C; Heiss, Wolf-Dieter; Ebinger, Martin; Fiebach, Jochen B; Sobesky, Jan

    2016-01-01

    With regard to acute stroke, patients with unknown time from stroke onset are not eligible for thrombolysis. Quantitative diffusion weighted imaging (DWI) and fluid attenuated inversion recovery (FLAIR) MRI relative signal intensity (rSI) biomarkers have been introduced to predict eligibility for thrombolysis, but have shown heterogeneous results in the past. In the present work, we investigated whether the inclusion of easily obtainable clinical-radiological parameters would improve the prediction of the thrombolysis time window by rSIs and compared their performance to the visual DWI-FLAIR mismatch. In a retrospective study, patients from 2 centers with proven stroke with onset <12 h were included. The DWI lesion was segmented and overlaid on ADC and FLAIR images. rSI mean and SD, were calculated as follows: (mean ROI value/mean value of the unaffected hemisphere). Additionally, the visual DWI-FLAIR mismatch was evaluated. Prediction of the thrombolysis time window was evaluated by the area-under-the-curve (AUC) derived from receiver operating characteristic (ROC) curve analysis. Factors such as the association of age, National Institutes of Health Stroke Scale, MRI field strength, lesion size, vessel occlusion and Wahlund-Score with rSI were investigated and the models were adjusted and stratified accordingly. In 82 patients, the unadjusted rSI measures DWI-mean and -SD showed the highest AUCs (AUC 0.86-0.87). Adjustment for clinical-radiological covariates significantly improved the performance of FLAIR-mean (0.91) and DWI-SD (0.91). The best prediction results based on the AUC were found for the final stratified and adjusted models of DWI-SD (0.94) and FLAIR-mean (0.96) and a multivariable DWI-FLAIR model (0.95). The adjusted visual DWI-FLAIR mismatch did not perform in a significantly worse manner (0.89). ADC-rSIs showed fair performance in all models. Quantitative DWI and FLAIR MRI biomarkers as well as the visual DWI-FLAIR mismatch provide excellent prediction of eligibility for thrombolysis in acute stroke, when easily obtainable clinical-radiological parameters are included in the prediction models. © 2016 S. Karger AG, Basel.

  14. Clinical excellence in academia: perspectives from masterful academic clinicians.

    PubMed

    Christmas, Colleen; Kravet, Steven J; Durso, Samuel C; Wright, Scott M

    2008-09-01

    To better understand and characterize clinical excellence in academia by exploring the perspectives of clinically excellent faculty in the top American departments of medicine. Between March 1 and May 31, 2007, 2 investigators conducted in-depth semistructured interviews with 24 clinically excellent Department of Medicine physicians at 8 academic institutions. Interview transcripts were independently analyzed by 2 investigators and compared for agreement. Content analysis identified several major themes that relate to clinical excellence in academia. Physicians hailed from a range of internal medicine specialties; 20 (83%) were associate professors or professors and 8 (33%) were women. The mean percentage of time physicians spent in clinical care was 48%. Eight domains emerged as the major features of clinical excellence in academia: reputation, communication and interpersonal skills, professionalism and humanism, diagnostic acumen, skillful negotiation of the health care system, knowledge, scholarly approach to clinical care, and passion for clinical medicine. Understanding the core elements that contribute to clinical excellence in academia represents a pivotal step to defining clinical excellence in this setting. It is hoped that such work will lead to initiatives aimed at measuring and rewarding clinical excellence in our academic medical centers such that the most outstanding clinicians feel valued and decide to stay in academia to serve as role models for medical trainees.

  15. Control of the repeatability of high frequency multibeam echosounder backscatter by using natural reference areas

    NASA Astrophysics Data System (ADS)

    Roche, Marc; Degrendele, Koen; Vrignaud, Christophe; Loyer, Sophie; Le Bas, Tim; Augustin, Jean-Marie; Lurton, Xavier

    2018-06-01

    The increased use of backscatter measurements in time series for environmental monitoring necessitates the comparability of individual results. With the current lack of pre-calibrated multibeam echosounder systems for absolute backscatter measurement, a pragmatic solution is the use of natural reference areas for ensuring regular assessment of the backscatter measurement repeatability. This method mainly relies on the assumption of a sufficiently stable reference area regarding its backscatter signature. The aptitude of a natural area to provide a stable and uniform backscatter response must be carefully considered and demonstrated by a sufficiently long time-series of measurements. Furthermore, this approach requires a strict control of the acquisition and processing parameters. If all these conditions are met, stability check and relative calibration of a system are possible by comparison with the averaged backscatter values for the area. Based on a common multibeam echosounder and sampling campaign completed by available bathymetric and backscatter time series, the suitability as a backscatter reference area of three different candidates was evaluated. Two among them, Carré Renard and Kwinte, prove to be excellent choices, while the third one, Western Solent, lacks sufficient data over time, but remains a valuable candidate. The case studies and the available backscatter data on these areas prove the applicability of this method. The expansion of the number of commonly used reference areas and the growth of the number of multibeam echosounder controlled thereon could greatly contribute to the further development of quantitative applications based on multibeam echosounder backscatter measurements.

  16. Escape Excel: A tool for preventing gene symbol and accession conversion errors.

    PubMed

    Welsh, Eric A; Stewart, Paul A; Kuenzi, Brent M; Eschrich, James A

    2017-01-01

    Microsoft Excel automatically converts certain gene symbols, database accessions, and other alphanumeric text into dates, scientific notation, and other numerical representations. These conversions lead to subsequent, irreversible, corruption of the imported text. A recent survey of popular genomic literature estimates that one-fifth of all papers with supplementary gene lists suffer from this issue. Here, we present an open-source tool, Escape Excel, which prevents these erroneous conversions by generating an escaped text file that can be safely imported into Excel. Escape Excel is implemented in a variety of formats (http://www.github.com/pstew/escape_excel), including a command line based Perl script, a Windows-only Excel Add-In, an OS X drag-and-drop application, a simple web-server, and as a Galaxy web environment interface. Test server implementations are accessible as a Galaxy interface (http://apostl.moffitt.org) and simple non-Galaxy web server (http://apostl.moffitt.org:8000/). Escape Excel detects and escapes a wide variety of problematic text strings so that they are not erroneously converted into other representations upon importation into Excel. Examples of problematic strings include date-like strings, time-like strings, leading zeroes in front of numbers, and long numeric and alphanumeric identifiers that should not be automatically converted into scientific notation. It is hoped that greater awareness of these potential data corruption issues, together with diligent escaping of text files prior to importation into Excel, will help to reduce the amount of Excel-corrupted data in scientific analyses and publications.

  17. Quantitative reflection spectroscopy at the human ocular fundus

    NASA Astrophysics Data System (ADS)

    Hammer, Martin; Schweitzer, Dietrich

    2002-01-01

    A new model of the reflection of the human ocular fundus on the basis of the adding-doubling method, an approximate solution of the radiative transport equation, is described. This model enables the calculation of the concentrations of xanthophyll in the retina, of melanin in the retinal pigment epithelium and the choroid, and of haemoglobin in the choroid from fundus reflection spectra. The concentration values found in 12 healthy subjects are in excellent agreement with published data. In individual cases of pathologic fundus alterations, possible benefits to the ophthalmologic diagnostics are demonstrated.

  18. Influence of artificial shock absorbers on human gait.

    PubMed

    Voloshin, A; Wosk, J

    1981-10-01

    The effect of artificial shock absorbers on the human gait and the technique for its quantitative evaluation have been studied. The results obtained have shown that viscoelastic inserts reduced the amplitude of the incoming shock waves bearing upon the musculoskeletal system as a result of the heel strike, by 42 percent (mean value). Conservative treatment, using such inserts for patients with different clinical symptoms of degenerative joint diseases, has shown excellent results. Seventy-eight percent of the clinical symptoms disappeared, while satisfactory improvement was reported in 17 percent of the subjects.

  19. Absolute Helmholtz free energy of highly anharmonic crystals: theory vs Monte Carlo.

    PubMed

    Yakub, Lydia; Yakub, Eugene

    2012-04-14

    We discuss the problem of the quantitative theoretical prediction of the absolute free energy for classical highly anharmonic solids. Helmholtz free energy of the Lennard-Jones (LJ) crystal is calculated accurately while accounting for both the anharmonicity of atomic vibrations and the pair and triple correlations in displacements of the atoms from their lattice sites. The comparison with most precise computer simulation data on sublimation and melting lines revealed that theoretical predictions are in excellent agreement with Monte Carlo simulation data in the whole range of temperatures and densities studied.

  20. Making the right moves: promoting smart growth and active aging in communities.

    PubMed

    Sykes, Kathleen E; Robinson, Kristen N

    2014-01-01

    This article describes an award program sponsored by the U.S. Environmental Protection Agency for excellence in smart growth and active aging. Having examined qualitative and quantitative data, we suggest that any community can foster changes to improve the health and well-being of its aging population. Diverse winners took unique paths to change their built environments and encourage physical activity. The policy changes undertaken by the award winners have both short- and long-term benefits that are important for persons of all ages, but especially for an aging society.

  1. Global Warming - Are We on Thin Ice?

    NASA Technical Reports Server (NTRS)

    Tucker, Compton J.

    2007-01-01

    The evidence for global warming is very conclusive for the past 400-500 years. Prior to the 16th century, proxy surface temperature data are regionally good but lack a global distribution. The speaker will review surface temperature reconstruction based upon ice cores, coral cores, tree rings, deep sea sediments, and bore holes and discuss the controversy surrounding global warming. This will be contrasted with the excellent data we have from the satellite era of earth observations the past 30+ years that enables the quantitative study of climate across earth science disciplines.

  2. Absolute spectrophotometry of Titan, Uranus, and Neptune 3500-10,500 A

    NASA Technical Reports Server (NTRS)

    Neff, J. S.; Humm, D. C.; Bergstralh, J. T.; Cochran, A. L.; Cochran, W. D.; Barker, E. S.; Tull, R. G.

    1984-01-01

    The present absolute measurements of Titan, Uranus and Neptune geometric albedo spectra in the 3500-10,500 A range have a resolution of about 7 A, together with high SNR, in virtue of the exceptional effeciency of the spectrograph and Reticon detector employed. The high precision and spectral resolution of the data, which are in excellent agreement with the Uranus albedo measurements of Lockwood et al. (1983), make possible quantitative measurements of the effects of Raman scattering by H2 in the Uranus and Neptune atmospheres.

  3. Detecting evidence of luteal activity by least-squares quantitative basal temperature analysis against urinary progesterone metabolites and the effect of wake-time variability.

    PubMed

    Bedford, Jennifer L; Prior, Jerilynn C; Hitchcock, Christine L; Barr, Susan I

    2009-09-01

    To assess computerised least-squares analysis of quantitative basal temperature (LS-BT) against urinary pregnanediol glucuronide (PdG) as an indirect measure of ovulation, and to evaluate the stability of LS-QBT to wake-time variation. Cross-sectional study of 40 healthy, normal-weight, regularly menstruating women aged 19-34. Participants recorded basal temperature and collected first void urine daily for one complete menstrual cycle. Evidence of luteal activity (ELA), an indirect ovulation indicator, was assessed using Kassam's PdG algorithm, which identifies a sustained 3-day PdG rise, and the LS-QBT algorithm, by determining whether the temperature curve is significantly biphasic. Cycles were classified as ELA(+) or ELA(-). We explored the need to pre-screen for wake-time variations by repeating the analysis using: (A) all recorded temperatures, (B) wake-time adjusted temperatures, (C) temperatures within 2h of average wake-time, and (D) expert reviewed temperatures. Relative to PdG, classification of cycles as ELA(+) was 35 of 36 for LS-QBT methods A and B, 33 of 34 (method C) and 30 of 31 (method D). Classification of cycles as ELA(-) was 1 of 4 (methods A and B) and 0 of 3 (methods C and D). Positive predictive value was 92% for methods A-C and 91% for method D. Negative predictive value was 50% for methods A and B and 0% for methods C and D. Overall accuracy was 90% for methods A and B, 89% for method C and 88% for method D. The day of a significant temperature increase by LS-QBT and the first day of a sustained PdG rise were correlated (r=0.803, 0.741, 0.651, 0.747 for methods A-D, respectively, all p<0.001). LS-QBT showed excellent detection of ELA(+) cycles (sensitivity, positive predictive value) but poor detection of ELA(-) cycles (specificity, negative predictive value) relative to urinary PdG. Correlations between the methods and overall accuracy were good and similar for all analyses. Findings suggest that LS-QBT is robust to wake-time variability and that expert interpretation is unnecessary. This method shows promise for use as an epidemiological tool to document cyclic progesterone increase. Further validation relative to daily transvaginal ultrasound is required.

  4. Relative quantitation of glycoisoforms of intact apolipoprotein C3 in human plasma by liquid chromatography-high-resolution mass spectrometry.

    PubMed

    Jian, Wenying; Edom, Richard W; Wang, Dai; Weng, Naidong; Zhang, Stanley Weihua

    2013-03-05

    Glycosylation is one of the most important post-translational modifications to mammalian proteins. Distribution of different glycoisoforms of certain proteins may reflect disease conditions and, therefore, can potentially be utilized as biomarkers. Apolipoprotein C3 (ApoC3) is one of the many plasma glycoproteins extensively studied for association with disease states. ApoC3 exists in three main glycoisoforms, including ApoC3-1 and ApoC3-2, which contain an O-linked carbohydrate moiety consisting of three and four monosaccharide residues, respectively, and ApoC3-0 that lacks the entire glycosylation chain. Changes in the ratio of different glycoisoforms of ApoC3 have been observed in pathological conditions such as kidney disease, liver disease, and diabetes. They may provide important information for diagnosis, prognosis, and evaluation of therapeutic response for metabolic conditions. In this current work, a liquid chromatography (LC)-high-resolution (HR) time-of-flight (TOF) mass spectrometry (MS) method was developed for relative quantitation of different glycoisoforms of intact ApoC3 in human plasma. The samples were processed using a solid-phase extraction (SPE) method and then subjected to LC-full scan HRMS analysis. Isotope peaks for each targeted glycoisoform at two charge states were extracted using a window of 50 mDa and integrated into a chromatographic peak. The peak area ratios of ApoC3-1/ApoC3-0 and ApoC3-2/ApoC3-0 were calculated and evaluated for assay performance. The results indicated that the ratio can be determined with excellent reproducibility in multiple subjects. It has also been observed that the ratios remained constant in plasma exposed to room temperature, freeze-thaw cycles, and long-term frozen storage. The method was applied in preliminary biomarker research of diabetes by analyzing plasma samples collected from normal, prediabetic, and diabetic subjects. Significant differences were revealed in the ApoC3-1/ApoC3-0 ratio and in the ApoC3-2/ApoC3-0 ratio among the three groups. The workflow of intact protein analysis using full scan HRMS established in this current work can be potentially extended to relative quantitation of other glycosylated proteins. To our best knowledge, this is the first time that a systematic approach of relative quantitation of targeted intact protein glycoisoforms using LC-MS has been established and utilized in biomarker research.

  5. A Quantitative Approach to the Formal Verification of Real-Time Systems.

    DTIC Science & Technology

    1996-09-01

    Computer Science A Quantitative Approach to the Formal Verification of Real - Time Systems Sergio Vale Aguiar Campos September 1996 CMU-CS-96-199...ptisiic raieaiSI v Diambimos Lboiamtad _^ A Quantitative Approach to the Formal Verification of Real - Time Systems Sergio Vale Aguiar Campos...implied, of NSF, the Semiconduc- tor Research Corporation, ARPA or the U.S. government. Keywords: real - time systems , formal verification, symbolic

  6. Chromatographic peak resolution using Microsoft Excel Solver. The merit of time shifting input arrays.

    PubMed

    Dasgupta, Purnendu K

    2008-12-05

    Resolution of overlapped chromatographic peaks is generally accomplished by modeling the peaks as Gaussian or modified Gaussian functions. It is possible, even preferable, to use actual single analyte input responses for this purpose and a nonlinear least squares minimization routine such as that provided by Microsoft Excel Solver can then provide the resolution. In practice, the quality of the results obtained varies greatly due to small shifts in retention time. I show here that such deconvolution can be considerably improved if one or more of the response arrays are iteratively shifted in time.

  7. Excel Exercises for First-Year Engineering Students

    ERIC Educational Resources Information Center

    Wagner, Geri

    2006-01-01

    Several Excel applications are presented which are part of the syllabus in the first semester of engineering studies at Haugesund College. The aim of the applications is for the students to acquire both computing skills and mathematical understanding at the same time. The applications cover numerical solution of equations, differentiation,…

  8. Defining and Measuring Teaching Excellence in Higher Education in the 21st Century

    ERIC Educational Resources Information Center

    De Courcy, Eileen

    2015-01-01

    Higher Education is in a time of immense change. Colleges and Universities are under greater pressure to demonstrate their value while experiencing increasing levels of economic constraints, changing accountability structures, and pressure to demonstrate excellence in teaching and learning/student outcomes. Technology, elearning and massification…

  9. Longitudinal, label-free, quantitative tracking of cell death and viability in a 3D tumor model with OCT

    NASA Astrophysics Data System (ADS)

    Jung, Yookyung; Klein, Oliver J.; Wang, Hequn; Evans, Conor L.

    2016-06-01

    Three-dimensional in vitro tumor models are highly useful tools for studying tumor growth and treatment response of malignancies such as ovarian cancer. Existing viability and treatment assessment assays, however, face shortcomings when applied to these large, complex, and heterogeneous culture systems. Optical coherence tomography (OCT) is a noninvasive, label-free, optical imaging technique that can visualize live cells and tissues over time with subcellular resolution and millimeters of optical penetration depth. Here, we show that OCT is capable of carrying out high-content, longitudinal assays of 3D culture treatment response. We demonstrate the usage and capability of OCT for the dynamic monitoring of individual and combination therapeutic regimens in vitro, including both chemotherapy drugs and photodynamic therapy (PDT) for ovarian cancer. OCT was validated against the standard LIVE/DEAD Viability/Cytotoxicity Assay in small tumor spheroid cultures, showing excellent correlation with existing standards. Importantly, OCT was shown to be capable of evaluating 3D spheroid treatment response even when traditional viability assays failed. OCT 3D viability imaging revealed synergy between PDT and the standard-of-care chemotherapeutic carboplatin that evolved over time. We believe the efficacy and accuracy of OCT in vitro drug screening will greatly contribute to the field of cancer treatment and therapy evaluation.

  10. Depth-time interpolation of feature trends extracted from mobile microelectrode data with kernel functions.

    PubMed

    Wong, Stephen; Hargreaves, Eric L; Baltuch, Gordon H; Jaggi, Jurg L; Danish, Shabbar F

    2012-01-01

    Microelectrode recording (MER) is necessary for precision localization of target structures such as the subthalamic nucleus during deep brain stimulation (DBS) surgery. Attempts to automate this process have produced quantitative temporal trends (feature activity vs. time) extracted from mobile MER data. Our goal was to evaluate computational methods of generating spatial profiles (feature activity vs. depth) from temporal trends that would decouple automated MER localization from the clinical procedure and enhance functional localization in DBS surgery. We evaluated two methods of interpolation (standard vs. kernel) that generated spatial profiles from temporal trends. We compared interpolated spatial profiles to true spatial profiles that were calculated with depth windows, using correlation coefficient analysis. Excellent approximation of true spatial profiles is achieved by interpolation. Kernel-interpolated spatial profiles produced superior correlation coefficient values at optimal kernel widths (r = 0.932-0.940) compared to standard interpolation (r = 0.891). The choice of kernel function and kernel width resulted in trade-offs in smoothing and resolution. Interpolation of feature activity to create spatial profiles from temporal trends is accurate and can standardize and facilitate MER functional localization of subcortical structures. The methods are computationally efficient, enhancing localization without imposing additional constraints on the MER clinical procedure during DBS surgery. Copyright © 2012 S. Karger AG, Basel.

  11. Synthesis of a Fluorescently Labeled 68Ga-DOTA-TOC Analog for Somatostatin Receptor Targeting.

    PubMed

    Ghosh, Sukhen C; Hernandez Vargas, Servando; Rodriguez, Melissa; Kossatz, Susanne; Voss, Julie; Carmon, Kendra S; Reiner, Thomas; Schonbrunn, Agnes; Azhdarinia, Ali

    2017-07-13

    Fluorescently labeled imaging agents can identify surgical margins in real-time to help achieve complete resections and minimize the likelihood of local recurrence. However, photon attenuation limits fluorescence-based imaging to superficial lesions or lesions that are a few millimeters beneath the tissue surface. Contrast agents that are dual-labeled with a radionuclide and fluorescent dye can overcome this limitation and combine quantitative, whole-body nuclear imaging with intraoperative fluorescence imaging. Using a multimodality chelation (MMC) scaffold, IRDye 800CW was conjugated to the clinically used somatostatin analog, 68 Ga-DOTA-TOC, to produce the dual-labeled analog, 68 Ga-MMC(IRDye 800CW)-TOC, with high yield and specific activity. In vitro pharmacological assays demonstrated retention of receptor-targeting properties for the dual-labeled compound with robust internalization that was somatostatin receptor (SSTR) 2-mediated. Biodistribution studies in mice identified the kidneys as the primary excretion route for 68 Ga-MMC(IRDye 800CW)-TOC, along with clearance via the reticuloendothelial system. Higher uptake was observed in most tissues compared to 68 Ga-DOTA-TOC but decreased as a function of time. The combination of excellent specificity for SSTR2-expressing cells and suitable biodistribution indicate potential application of 68 Ga-MMC(IRDye 800CW)-TOC for intraoperative detection of SSTR2-expressing tumors.

  12. Subunit mass analysis for monitoring antibody oxidation.

    PubMed

    Sokolowska, Izabela; Mo, Jingjie; Dong, Jia; Lewis, Michael J; Hu, Ping

    2017-04-01

    Methionine oxidation is a common posttranslational modification (PTM) of monoclonal antibodies (mAbs). Oxidation can reduce the in-vivo half-life, efficacy and stability of the product. Peptide mapping is commonly used to monitor the levels of oxidation, but this is a relatively time-consuming method. A high-throughput, automated subunit mass analysis method was developed to monitor antibody methionine oxidation. In this method, samples were treated with IdeS, EndoS and dithiothreitol to generate three individual IgG subunits (light chain, Fd' and single chain Fc). These subunits were analyzed by reversed phase-ultra performance liquid chromatography coupled with an online quadrupole time-of-flight mass spectrometer and the levels of oxidation on each subunit were quantitated based on the deconvoluted mass spectra using the UNIFI software. The oxidation results obtained by subunit mass analysis correlated well with the results obtained by peptide mapping. Method qualification demonstrated that this subunit method had excellent repeatability and intermediate precision. In addition, UNIFI software used in this application allows automated data acquisition and processing, which makes this method suitable for high-throughput process monitoring and product characterization. Finally, subunit mass analysis revealed the different patterns of Fc methionine oxidation induced by chemical and photo stress, which makes it attractive for investigating the root cause of oxidation.

  13. The analysis of image feature robustness using cometcloud

    PubMed Central

    Qi, Xin; Kim, Hyunjoo; Xing, Fuyong; Parashar, Manish; Foran, David J.; Yang, Lin

    2012-01-01

    The robustness of image features is a very important consideration in quantitative image analysis. The objective of this paper is to investigate the robustness of a range of image texture features using hematoxylin stained breast tissue microarray slides which are assessed while simulating different imaging challenges including out of focus, changes in magnification and variations in illumination, noise, compression, distortion, and rotation. We employed five texture analysis methods and tested them while introducing all of the challenges listed above. The texture features that were evaluated include co-occurrence matrix, center-symmetric auto-correlation, texture feature coding method, local binary pattern, and texton. Due to the independence of each transformation and texture descriptor, a network structured combination was proposed and deployed on the Rutgers private cloud. The experiments utilized 20 randomly selected tissue microarray cores. All the combinations of the image transformations and deformations are calculated, and the whole feature extraction procedure was completed in 70 minutes using a cloud equipped with 20 nodes. Center-symmetric auto-correlation outperforms all the other four texture descriptors but also requires the longest computational time. It is roughly 10 times slower than local binary pattern and texton. From a speed perspective, both the local binary pattern and texton features provided excellent performance for classification and content-based image retrieval. PMID:23248759

  14. Optimal satellite sampling to resolve global-scale dynamics in the I-T system

    NASA Astrophysics Data System (ADS)

    Rowland, D. E.; Zesta, E.; Connor, H. K.; Pfaff, R. F., Jr.

    2016-12-01

    The recent Decadal Survey highlighted the need for multipoint measurements of ion-neutral coupling processes to study the pathways by which solar wind energy drives dynamics in the I-T system. The emphasis in the Decadal Survey is on global-scale dynamics and processes, and in particular, mission concepts making use of multiple identical spacecraft in low earth orbit were considered for the GDC and DYNAMIC missions. This presentation will provide quantitative assessments of the optimal spacecraft sampling needed to significantly advance our knowledge of I-T dynamics on the global scale.We will examine storm time and quiet time conditions as simulated by global circulation models, and determine how well various candidate satellite constellations and satellite schemes can quantify the plasma and neutral convection patterns and global-scale distributions of plasma density, neutral density, and composition, and their response to changes in the IMF. While the global circulation models are data-starved, and do not contain all the physics that we might expect to observe with a global-scale constellation mission, they are nonetheless an excellent "starting point" for discussions of the implementation of such a mission. The result will be of great utility for the design of future missions, such as GDC, to study the global-scale dynamics of the I-T system.

  15. A Rabbit Model for Testing Helper-Dependent Adenovirus-Mediated Gene Therapy for Vein Graft Atherosclerosis.

    PubMed

    Bi, Lianxiang; Wacker, Bradley K; Bueren, Emma; Ham, Ervin; Dronadula, Nagadhara; Dichek, David A

    2017-12-15

    Coronary artery bypass vein grafts are a mainstay of therapy for human atherosclerosis. Unfortunately, the long-term patency of vein grafts is limited by accelerated atherosclerosis. Gene therapy, directed at the vein graft wall, is a promising approach for preventing vein graft atherosclerosis. Because helper-dependent adenovirus (HDAd) efficiently transduces grafted veins and confers long-term transgene expression, HDAd is an excellent candidate for delivery of vein graft-targeted gene therapy. We developed a model of vein graft atherosclerosis in fat-fed rabbits and demonstrated long-term (≥20 weeks) persistence of HDAd genomes after graft transduction. This model enables quantitation of vein graft hemodynamics, wall structure, lipid accumulation, cellularity, vector persistence, and inflammatory markers on a single graft. Time-course experiments identified 12 weeks after transduction as an optimal time to measure efficacy of gene therapy on the critical variables of lipid and macrophage accumulation. We also used chow-fed rabbits to test whether HDAd infusion in vein grafts promotes intimal growth and inflammation. HDAd did not increase intimal growth, but had moderate-yet significant-pro-inflammatory effects. The vein graft atherosclerosis model will be useful for testing HDAd-mediated gene therapy; however, pro-inflammatory effects of HdAd remain a concern in developing HDAd as a therapy for vein graft disease.

  16. Quantitative evaluation of alternatively spliced mRNA isoforms by label-free real-time plasmonic sensing.

    PubMed

    Huertas, César S; Carrascosa, L G; Bonnal, S; Valcárcel, J; Lechuga, L M

    2016-04-15

    Alternative splicing of mRNA precursors enables cells to generate different protein outputs from the same gene depending on their developmental or homeostatic status. Its deregulation is strongly linked to disease onset and progression. Current methodologies for monitoring alternative splicing demand elaborate procedures and often present difficulties in discerning between closely related isoforms, e.g. due to cross-hybridization during their detection. Herein, we report a general methodology using a Surface Plasmon Resonance (SPR) biosensor for label-free monitoring of alternative splicing events in real-time, without any cDNA synthesis or PCR amplification requirements. We applied this methodology to RNA isolated from HeLa cells for the quantification of alternatively spliced isoforms of the Fas gene, involved in cancer progression through regulation of programmed cell death. We demonstrate that our methodology is isoform-specific, with virtually no cross-hybridization, achieving limits of detection (LODs) in the picoMolar (pM) range. Similar results were obtained for the detection of the BCL-X gene mRNA isoforms. The results were independently validated by RT-qPCR, with excellent concordance in the determination of isoform ratios. The simplicity and robustness of this biosensor technology can greatly facilitate the exploration of alternative splicing biomarkers in disease diagnosis and therapy. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Increasing the computational efficient of digital cross correlation by a vectorization method

    NASA Astrophysics Data System (ADS)

    Chang, Ching-Yuan; Ma, Chien-Ching

    2017-08-01

    This study presents a vectorization method for use in MATLAB programming aimed at increasing the computational efficiency of digital cross correlation in sound and images, resulting in a speedup of 6.387 and 36.044 times compared with performance values obtained from looped expression. This work bridges the gap between matrix operations and loop iteration, preserving flexibility and efficiency in program testing. This paper uses numerical simulation to verify the speedup of the proposed vectorization method as well as experiments to measure the quantitative transient displacement response subjected to dynamic impact loading. The experiment involved the use of a high speed camera as well as a fiber optic system to measure the transient displacement in a cantilever beam under impact from a steel ball. Experimental measurement data obtained from the two methods are in excellent agreement in both the time and frequency domain, with discrepancies of only 0.68%. Numerical and experiment results demonstrate the efficacy of the proposed vectorization method with regard to computational speed in signal processing and high precision in the correlation algorithm. We also present the source code with which to build MATLAB-executable functions on Windows as well as Linux platforms, and provide a series of examples to demonstrate the application of the proposed vectorization method.

  18. Indirect Observation in Everyday Contexts: Concepts and Methodological Guidelines within a Mixed Methods Framework.

    PubMed

    Anguera, M Teresa; Portell, Mariona; Chacón-Moscoso, Salvador; Sanduvete-Chaves, Susana

    2018-01-01

    Indirect observation is a recent concept in systematic observation. It largely involves analyzing textual material generated either indirectly from transcriptions of audio recordings of verbal behavior in natural settings (e.g., conversation, group discussions) or directly from narratives (e.g., letters of complaint, tweets, forum posts). It may also feature seemingly unobtrusive objects that can provide relevant insights into daily routines. All these materials constitute an extremely rich source of information for studying everyday life, and they are continuously growing with the burgeoning of new technologies for data recording, dissemination, and storage. Narratives are an excellent vehicle for studying everyday life, and quantitization is proposed as a means of integrating qualitative and quantitative elements. However, this analysis requires a structured system that enables researchers to analyze varying forms and sources of information objectively. In this paper, we present a methodological framework detailing the steps and decisions required to quantitatively analyze a set of data that was originally qualitative. We provide guidelines on study dimensions, text segmentation criteria, ad hoc observation instruments, data quality controls, and coding and preparation of text for quantitative analysis. The quality control stage is essential to ensure that the code matrices generated from the qualitative data are reliable. We provide examples of how an indirect observation study can produce data for quantitative analysis and also describe the different software tools available for the various stages of the process. The proposed method is framed within a specific mixed methods approach that involves collecting qualitative data and subsequently transforming these into matrices of codes (not frequencies) for quantitative analysis to detect underlying structures and behavioral patterns. The data collection and quality control procedures fully meet the requirement of flexibility and provide new perspectives on data integration in the study of biopsychosocial aspects in everyday contexts.

  19. Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays--LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5.

    PubMed

    Katsoulidou, Antigoni; Petrodaskalaki, Maria; Sypsa, Vana; Papachristou, Eleni; Anastassopoulou, Cleo G; Gargalianos, Panagiotis; Karafoulidou, Anastasia; Lazanas, Marios; Kordossis, Theodoros; Andoniadou, Anastasia; Hatzakis, Angelos

    2006-02-01

    The COBAS TaqMan HIV-1 test (Roche Diagnostics) was compared with the LCx HIV RNA quantitative assay (Abbott Laboratories), the Versant HIV-1 RNA 3.0 (bDNA) assay (Bayer) and the COBAS Amplicor HIV-1 Monitor v1.5 test (Roche Diagnostics), using plasma samples of various viral load levels from HIV-1-infected individuals. In the comparison of TaqMan with LCx, TaqMan identified as positive 77.5% of the 240 samples versus 72.1% identified by LCx assay, while their overall agreement was 94.6% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.91). Similarly, in the comparison of TaqMan with bDNA 3.0, both methods identified 76.3% of the 177 samples as positive, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.95). Finally, in the comparison of TaqMan with Monitor v1.5, TaqMan identified 79.5% of the 156 samples as positive versus 80.1% identified by Monitor v1.5, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.96). In conclusion, the new COBAS TaqMan HIV-1 test showed excellent agreement with other widely used commercially available tests for the quantitation of HIV-1 viral load.

  20. Highly Efficient and Facile Photocatalytic Recycling System Suitable for ICAR ATRP of Hydrophilic Monomers.

    PubMed

    Jiang, Xiaowu; Zhang, Lifen; Cheng, Zhenping; Zhu, Xiulin

    2016-08-01

    Photoinduced initiators for continuous activator regeneration atom transfer radical polymerization (ATRP) of hydrophilic monomers in heptane/ethanol latent-biphasic system for copper catalyst separation and recycling have been realized for the first time at room temperature with different wavelengths of visible light LED (green, blue, purple, and white LED) as external stimulus, using 2-bromophenylacetate as the ATRP initiator and camphorquinone/triethylamine as the photoinitiator. In this system, hybrid catalyst complex (HCc) is synthesized as a novel nonpolar catalyst, which is preferentially dissolved in heptane. The hydrophilic polymers obtained catalyzed by HCc in heptane/ethanol mixture solvent show typical "living" features, for example, the values of Mn,GPC increase linearly with monomer conversion up to quantitative level (>96%) and the molecular weight distributions were kept narrow (Mw /Mn < 1.20) throughout the polymerization process. It should be noted that the excellent controllability of this novel polymerization system can be achieved even after 5 catalyst recycling experiments under LED irradiation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Free Cooling of a Granular Gas of Rodlike Particles in Microgravity

    NASA Astrophysics Data System (ADS)

    Harth, Kirsten; Trittel, Torsten; Wegner, Sandra; Stannarius, Ralf

    2018-05-01

    Granular gases as dilute ensembles of particles in random motion are at the basis of elementary structure-forming processes in the Universe, involved in many industrial and natural phenomena, and also excellent models to study fundamental statistical dynamics. The essential difference to molecular gases is the energy dissipation in particle collisions. Its most striking manifestation is the so-called granular cooling, the gradual loss of mechanical energy E (t ) in the absence of external excitation. We report an experimental study of homogeneous cooling of three-dimensional granular gases in microgravity. The asymptotic scaling E (t )∝t-2 obtained by Haff's minimal model [J. Fluid Mech. 134, 401 (1983), 10.1017/S0022112083003419] proves to be robust, despite the violation of several of its central assumptions. The shape anisotropy of the grains influences the characteristic time of energy loss quantitatively but not qualitatively. We compare kinetic energies in the individual degrees of freedom and find a slight predominance of translational motions. In addition, we observe a preferred rod alignment in the flight direction, as known from active matter or animal flocks.

  2. Characterization of diabetic nephropathy in CaM kinase IIalpha (Thr286Asp) transgenic mice.

    PubMed

    Suzuki, Hikari; Kato, Ichiro; Usui, Isao; Takasaki, Ichiro; Tabuchi, Yoshiaki; Oya, Takeshi; Tsuneyama, Koichi; Kawaguchi, Hiroshi; Hiraga, Koichi; Takasawa, Shin; Okamoto, Hiroshi; Tobe, Kazuyuki; Sasahara, Masakiyo

    2009-01-30

    Detailed studies were performed on diabetic kidneys derived from transgenic mice overexpressing the mutant form (Thr286Asp) of Ca(2+)/calmodulin-dependent protein kinase IIalpha (CaM kinase IIalpha) in pancreatic beta-cells. Kidney weight/body weight ratio, urinary albumin/creatinine ratio, serum BUN level, and mesangial/glomerular area ratio were all significantly higher in transgenic mice than in wild-type mice. cDNA microarray analysis revealed 17 up-regulated genes and 12 down-regulated genes in transgenic kidney. Among up-regulated genes, cyclin D2 (6.70-fold) and osteopontin (2.35-fold) were thought to play important roles in the progression of diabetic nephropathy. Transgenic glomeruli and tubular epithelial cells were strongly stained for osteopontin, a molecule which induces immune response. In quantitative real-time RT-PCR analyses, expressions of not only M1 macrophage marker genes but also M2 macrophage marker genes were elevated in renal cortex of transgenic mice. Overall results indicate that CaM kinase IIalpha (Thr286Asp) transgenic mice serve as an excellent model for diabetic nephropathy.

  3. THE 6-MINUTE WALK TEST AND OTHER CLINICAL ENDPOINTS IN DUCHENNE MUSCULAR DYSTROPHY: RELIABILITY, CONCURRENT VALIDITY, AND MINIMAL CLINICALLY IMPORTANT DIFFERENCES FROM A MULTICENTER STUDY

    PubMed Central

    McDonald, Craig M; Henricson, Erik K; Abresch, R Ted; Florence, Julaine; Eagle, Michelle; Gappmaier, Eduard; Glanzman, Allan M; Spiegel, Robert; Barth, Jay; Elfring, Gary; Reha, Allen; Peltz, Stuart W

    2013-01-01

    Introduction: An international clinical trial enrolled 174 ambulatory males ≥5 years old with nonsense mutation Duchenne muscular dystrophy (nmDMD). Pretreatment data provide insight into reliability, concurrent validity, and minimal clinically important differences (MCIDs) of the 6-minute walk test (6MWT) and other endpoints. Methods: Screening and baseline evaluations included the 6-minute walk distance (6MWD), timed function tests (TFTs), quantitative strength by myometry, the PedsQL, heart rate–determined energy expenditure index, and other exploratory endpoints. Results: The 6MWT proved feasible and reliable in a multicenter context. Concurrent validity with other endpoints was excellent. The MCID for 6MWD was 28.5 and 31.7 meters based on 2 statistical distribution methods. Conclusions: The ratio of MCID to baseline mean is lower for 6MWD than for other endpoints. The 6MWD is an optimal primary endpoint for Duchenne muscular dystrophy (DMD) clinical trials that are focused therapeutically on preservation of ambulation and slowing of disease progression. Muscle Nerve 48: 357–368, 2013 PMID:23674289

  4. Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wood, William Monford

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less

  5. Shot-by-shot Spectrum Model for Rod-pinch, Pulsed Radiography Machines

    DOE PAGES

    Wood, William Monford

    2018-02-07

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thusmore » allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX”) model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. In conclusion, improvements to the model, specifically for application to other geometries, are discussed.« less

  6. Ultra-performance liquid chromatography tandem mass spectrometry for simultaneous determination of natural steroid hormones in sea lamprey (Petromyzon marinus) plasma and tissues.

    PubMed

    Wang, Huiyong; Bussy, Ugo; Chung-Davidson, Yu-Wen; Li, Weiming

    2016-01-15

    This study aims to provide a rapid, sensitive and precise UPLC-MS/MS method for target steroid quantitation in biological matrices. We developed and validated an UPLC-MS/MS method to simultaneously determine 16 steroids in plasma and tissue samples. Ionization sources of Electrospray Ionization (ESI) and Atmospheric Pressure Chemical Ionization (APCI) were compared in this study by testing their spectrometry performances at the same chromatographic conditions, and the ESI source was found up to five times more sensitive than the APCI. Different sample preparation techniques were investigated for an optimal extraction of steroids from the biological matrices. The developed method exhibited excellent linearity for all analytes with regression coefficients higher than 0.99 in broad concentration ranges. The limit of detection (LOD) was from 0.003 to 0.1ng/mL. The method was validated according to FDA guidance and applied to determine steroids in sea lamprey plasma and tissues (fat and testes) by the developed method. Copyright © 2015. Published by Elsevier B.V.

  7. Chemical characterization, antioxidant and antitumor activity of sulfated polysaccharide from Sargassum horneri.

    PubMed

    Shao, Ping; Chen, Xiaoxiao; Sun, Peilong

    2014-05-25

    Three water-soluble polysaccharide fractions (SHP30, SHP60, and SHP80) extracted from the Sargassum horneri were obtained by water extraction and radial flow chromatography. The high-performance gel-permeation chromatography analysis showed that the average molecular weight (Mw) of three polysaccharides were approximately 1.58×10(3), 1.92×10(3) and 11.2KDa, respectively. Their in vitro antioxidant activities, antitumor activities were investigated and compared. Among these three polysaccharides, SHP30 with the highest sulfate content and intermediate molecular weight exhibited excellent antioxidant and antitumor activities in the superoxide radical assay, hydroxyl radical assay, reducing power assay, and MTT assay. Then, flow cytometry assay and quantitative real-time reverse transcription-PCR analysis suggested that the accumulation of cells in G0/G1 and S phase effecting apoptosis-associated gene expressions such as Bcl-2 and Bax might account for the growth inhibition of DLD cells by SHP30. Based on these results, we have inferred that sulfate content and molecular weight were the factors influencing antioxidant and antitumor activities. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  8. ["Crisis"--oscillating between keyword and buzzword. On the discourse about a "crisis of medicine" in the Weimar Republic].

    PubMed

    Geiger, Karin

    2010-01-01

    The buzzword "crisis" has not only become omnipresent since the recent financial crisis. The term that originated in Ancient Greece underwent several different usages--quantitatively as well as qualitatively; especially in the Weimar Republic, the time period that has long been considered as the crisis era par excellence. Using the discourse about the "crisis of medicine" in the 1920s and the early 1930s as an example, the article attempts to provide a critical reflection on the concept of "crisis". The focus of this article is on the idea's construction, the different semantic usages of "crisis" and the motives of the different authors for their respective rhetorical applications of this term. The analysis of the examined publications on the "crisis of medicine", how they influenced other periods and the reconstruction of their origin show that the semantics of the word "crisis" went far beyond a simply negative connotation, and with regard to its rhetorical usage have oscillated between keyword and a meaningless but catchy buzzword.

  9. Fabrication of powdery polymer aerogel as the stationary phase for high-resolution gas chromatographic separation.

    PubMed

    Zheng, Juan; Lu, Cuiming; Huang, Junlong; Chen, Luyi; Ni, Chuyi; Xie, Xintong; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng

    2018-08-15

    Novel powdery polymer aerogel (PPA) prepared via the (micro)emulsion polymerization and the following hyper crosslinking reaction was fabricated as stationary phase of capillary column for the first time. Due to its powdery morphology, unique 3D nano-network structure, high surface area and good thermostability, the PPA-coated capillary column demonstrated high-resolution chromatographic separation towards nonpolar and weakly polar organic compounds, including benzene series, n-alkanes, ketone mixtures and trichlorobenzenes. Moreover, the reproducibility, quantitative analysis ability and thermostability of PPA-coated capillary column were also evaluated. The relative standard deviations for three replicate determinations of selected analytes were 0.02-0.11%, 0.12-0.26% and 1.2-3.6% for run-to-run, day-to-day and column-to-column analyses, respectively. The PPA demonstrated good thermostability, and the PPA-coated capillary column was proved to be heat-resistant (270 °C). The results of this study show PPA is an excellent candidate to be employed as stationary phase for gas chromatography capillary. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Performances of CN-columns for the analysis of γ-oryzanol and its p-coumarate and caffeate derivatives by normal phase HPLC and a validated method of quantitation.

    PubMed

    D'Ambrosio, Michele

    2013-06-15

    γ-Oryzanol is an important phytochemical used in pharmaceutical, alimentary and cosmetic preparations. The present article, for the first time, discloses the performances of NP-HPLC in separating γ-oryzanol components and develops a validated method for its routine quantification. The analysis is performed on a cyanopropyl bonded column using the hexane/MTBE gradient elution and UV detection at 325 nm. The method allows: the separation of steryl ferulate, p-coumarate and caffeate esters, the separation of cis- from trans-ferulate isomers, the splitting of steroid moieties into saturated and unsaturated at the side chain. The optimised method provides excellent linear response (R(2)=0.99997), high precision (RSD<1.0%) and satisfactory accuracy (R(∗)=70-86%). In conclusion, the established method presents the details of the procedure and the experimental conditions in order to achieve the required precision and instrumental accuracy. The method is fast and sensitive and it could be a suitable tool for quality assurance and determination of origin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Aberrant leukocyte telomere length in Birdshot Uveitis.

    PubMed

    Vazirpanah, Nadia; Verhagen, Fleurieke H; Rothova, Anna; Missotten, Tom O A R; van Velthoven, Mirjam; Den Hollander, Anneke I; Hoyng, Carel B; Radstake, Timothy R D J; Broen, Jasper C A; Kuiper, Jonas J W

    2017-01-01

    Birdshot Uveitis (BU) is an archetypical chronic inflammatory eye disease, with poor visual prognosis, that provides an excellent model for studying chronic inflammation. BU typically affects patients in the fifth decade of life. This suggests that it may represent an age-related chronic inflammatory disease, which has been linked to increased erosion of telomere length of leukocytes. To study this in detail, we exploited a sensitive standardized quantitative real-time polymerase chain reaction to determine the peripheral blood leukocyte telomere length (LTL) in 91 genotyped Dutch BU patients and 150 unaffected Dutch controls. Although LTL erosion rates were very similar between BU patients and healthy controls, we observed that BU patients displayed longer LTL, with a median of log (LTL) = 4.87 (= 74131 base pair) compared to 4.31 (= 20417 base pair) in unaffected controls (P<0.0001). The cause underpinning the difference in LTL could not be explained by clinical parameters, immune cell-subtype distribution, nor genetic predisposition based upon the computed weighted genetic risk score of genotyped validated variants in TERC, TERT, NAF1, OBFC1 and RTEL1. These findings suggest that BU is accompanied by significantly longer LTL.

  12. Nonlinear deformation and localized failure of bacterial streamers in creeping flows

    PubMed Central

    Biswas, Ishita; Ghosh, Ranajay; Sadrzadeh, Mohtada; Kumar, Aloke

    2016-01-01

    We investigate the failure of bacterial floc mediated streamers in a microfluidic device in a creeping flow regime using both experimental observations and analytical modeling. The quantification of streamer deformation and failure behavior is possible due to the use of 200 nm fluorescent polystyrene beads which firmly embed in the extracellular polymeric substance (EPS) and act as tracers. The streamers, which form soon after the commencement of flow begin to deviate from an apparently quiescent fully formed state in spite of steady background flow and limited mass accretion indicating significant mechanical nonlinearity. This nonlinear behavior shows distinct phases of deformation with mutually different characteristic times and comes to an end with a distinct localized failure of the streamer far from the walls. We investigate this deformation and failure behavior for two separate bacterial strains and develop a simplified but nonlinear analytical model describing the experimentally observed instability phenomena assuming a necking route to instability. Our model leads to a power law relation between the critical strain at failure and the fluid velocity scale exhibiting excellent qualitative and quantitative agreeing with the experimental rupture behavior. PMID:27558511

  13. Utility of surface enhanced Raman spectroscopy (SERS) for elucidation and simultaneous determination of some penicillins and penicilloic acid using hydroxylamine silver nanoparticles.

    PubMed

    El-Zahry, Marwa R; Refaat, Ibrahim H; Mohamed, Horria A; Rosenberg, Erwin; Lendl, Bernhard

    2015-11-01

    Elucidation and quantitative determination of some of commonly used penicillins (ampicillin, penicillin G and carbenicillin) in the presence of their main degradation product (penicilloic acid) were developed. Forced acidic and basic degradation processes were applied at different time intervals. The formed degradation products were elucidated and quantified using surface enhanced Raman spectroscopy (SERS). Silver nanoparticles (AgNPs) prepared by reduction of silver nitrate using hydroxylamine-HCl in alkaline medium were used as SERS substrate. The results obtained in SERS were confirmed by the application of LC/MS method. The concentration range was 100-600 ng/ml in case of the studied penicillins and 100-700 ng/ml in case of penicilloic acid. An excellent correlation coefficient was found in case of ampicillin (r=0.9993) and in the case of penicilloic acid (r=0.9997). Validation procedures were carried out including precision, robustness and accuracy by comparing F- and t-values of both the proposed and reported methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    NASA Astrophysics Data System (ADS)

    Wood, Wm M.

    2018-02-01

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  15. Piezoelectric microelectromechanical resonant sensors for chemical and biological detection.

    PubMed

    Pang, Wei; Zhao, Hongyuan; Kim, Eun Sok; Zhang, Hao; Yu, Hongyu; Hu, Xiaotang

    2012-01-07

    Piezoelectric microelectromechanical systems (MEMS) resonant sensors, known for their excellent mass resolution, have been studied for many applications, including DNA hybridization, protein-ligand interactions, and immunosensor development. They have also been explored for detecting antigens, organic gas, toxic ions, and explosives. Most piezoelectric MEMS resonant sensors are acoustic sensors (with specific coating layers) that enable selective and label-free detection of biological events in real time. These label-free technologies have recently garnered significant attention for their sensitive and quantitative multi-parameter analysis of biological systems. Since piezoelectric MEMS resonant sensors do more than transform analyte mass or thickness into an electrical signal (e.g., frequency and impedance), special attention must be paid to their potential beyond microweighing, such as measuring elastic and viscous properties, and several types of sensors currently under development operate at different resonant modes (i.e., thickness extensional mode, thickness shear mode, lateral extensional mode, flexural mode, etc.). In this review, we provide an overview of recent developments in micromachined resonant sensors and activities relating to biochemical interfaces for acoustic sensors.

  16. Second-order (2 +1 ) -dimensional anisotropic hydrodynamics

    NASA Astrophysics Data System (ADS)

    Bazow, Dennis; Heinz, Ulrich; Strickland, Michael

    2014-11-01

    We present a complete formulation of second-order (2 +1 ) -dimensional anisotropic hydrodynamics. The resulting framework generalizes leading-order anisotropic hydrodynamics by allowing for deviations of the one-particle distribution function from the spheroidal form assumed at leading order. We derive complete second-order equations of motion for the additional terms in the macroscopic currents generated by these deviations from their kinetic definition using a Grad-Israel-Stewart 14-moment ansatz. The result is a set of coupled partial differential equations for the momentum-space anisotropy parameter, effective temperature, the transverse components of the fluid four-velocity, and the viscous tensor components generated by deviations of the distribution from spheroidal form. We then perform a quantitative test of our approach by applying it to the case of one-dimensional boost-invariant expansion in the relaxation time approximation (RTA) in which case it is possible to numerically solve the Boltzmann equation exactly. We demonstrate that the second-order anisotropic hydrodynamics approach provides an excellent approximation to the exact (0+1)-dimensional RTA solution for both small and large values of the shear viscosity.

  17. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.

    PubMed

    Wang, Geng; Sun, Zhongwei; Jin, Quanmin; Xu, Kai; Li, Yi; Wang, Xiaozeng; Ma, Yingyan; Liu, Haiwei; Zhao, Xin; Wang, Bin; Deng, Jie; Guan, Shaoyi; Ge, Meiling; Wang, Xiaoyan; Xu, Bo; Han, Yaling

    2015-03-01

    To evaluate the preliminary safety and efficacy of the EXCEL II stent system. Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation. © 2015 Wiley Periodicals, Inc.

  18. High resolution quantitative phase imaging of live cells with constrained optimization approach

    NASA Astrophysics Data System (ADS)

    Pandiyan, Vimal Prabhu; Khare, Kedar; John, Renu

    2016-03-01

    Quantitative phase imaging (QPI) aims at studying weakly scattering and absorbing biological specimens with subwavelength accuracy without any external staining mechanisms. Use of a reference beam at an angle is one of the necessary criteria for recording of high resolution holograms in most of the interferometric methods used for quantitative phase imaging. The spatial separation of the dc and twin images is decided by the reference beam angle and Fourier-filtered reconstructed image will have a very poor resolution if hologram is recorded below a minimum reference angle condition. However, it is always inconvenient to have a large reference beam angle while performing high resolution microscopy of live cells and biological specimens with nanometric features. In this paper, we treat reconstruction of digital holographic microscopy images as a constrained optimization problem with smoothness constraint in order to recover only complex object field in hologram plane even with overlapping dc and twin image terms. We solve this optimization problem by gradient descent approach iteratively and the smoothness constraint is implemented by spatial averaging with appropriate size. This approach will give excellent high resolution image recovery compared to Fourier filtering while keeping a very small reference angle. We demonstrate this approach on digital holographic microscopy of live cells by recovering the quantitative phase of live cells from a hologram recorded with nearly zero reference angle.

  19. Prognostic significance of normal quantitative planar thallium-201 stress scintigraphy in patients with chest pain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wackers, F.J.; Russo, D.J.; Russo, D.

    The prognostic significance of normal quantitative planar thallium-201 stress scintigraphy was evaluated in patients with a chest pain syndrome. The prevalence of cardiac events during follow-up was related to the pretest (that is, before stress scintigraphy) likelihood of coronary artery disease determined on the basis of symptoms, age, sex and stress electrocardiography. In a consecutive series of 344 patients who had adequate thallium-201 stress scintigrams, 95 had unequivocally normal studies by quantitative analysis. The pretest likelihood of coronary artery disease in the 95 patients had a bimodal distribution. During a mean follow-up period of 22 +/- 3 months, no patientmore » died. Three patients (3%) had a cardiac event: two of these patients (pretest likelihood of coronary artery disease 54 and 94%) had a nonfatal myocardial infarction 8 and 22 months, respectively, after stress scintigraphy, and one patient (pretest likelihood 98%) underwent percutaneous transluminal coronary angioplasty 16 months after stress scintigraphy for persisting anginal complaints. Three patients were lost to follow-up; all three had a low pretest likelihood of coronary artery disease. It is concluded that patients with chest pain and normal findings on quantitative thallium-201 scintigraphy have an excellent prognosis. Cardiac events are rare (infarction rate 1% per year) and occur in patients with a moderate to high pretest likelihood of coronary artery disease.« less

  20. Digital pathology and image analysis for robust high-throughput quantitative assessment of Alzheimer disease neuropathologic changes.

    PubMed

    Neltner, Janna Hackett; Abner, Erin Lynn; Schmitt, Frederick A; Denison, Stephanie Kay; Anderson, Sonya; Patel, Ela; Nelson, Peter T

    2012-12-01

    Quantitative neuropathologic methods provide information that is important for both research and clinical applications. The technologic advancement of digital pathology and image analysis offers new solutions to enable valid quantification of pathologic severity that is reproducible between raters regardless of experience. Using an Aperio ScanScope XT and its accompanying image analysis software, we designed algorithms for quantitation of amyloid and tau pathologies on 65 β-amyloid (6F/3D antibody) and 48 phospho-tau (PHF-1)-immunostained sections of human temporal neocortex. Quantitative digital pathologic data were compared with manual pathology counts. There were excellent correlations between manually counted and digitally analyzed neuropathologic parameters (R² = 0.56-0.72). Data were highly reproducible among 3 participants with varying degrees of expertise in neuropathology (intraclass correlation coefficient values, >0.910). Digital quantification also provided additional parameters, including average plaque area, which shows statistically significant differences when samples are stratified according to apolipoprotein E allele status (average plaque area, 380.9 μm² in apolipoprotein E [Latin Small Letter Open E]4 carriers vs 274.4 μm² for noncarriers; p < 0.001). Thus, digital pathology offers a rigorous and reproducible method for quantifying Alzheimer disease neuropathologic changes and may provide additional insights into morphologic characteristics that were previously more challenging to assess because of technical limitations.

Top