Pushing x-ray photon correlation spectroscopy beyond the continuous frame rate limit
Dufresne, Eric M.; Narayanan, Suresh; Sandy, Alec R.; ...
2016-01-06
We demonstrate delayed-frame X-ray Photon Correlation Spectroscopy with 120 microsecond time resolution, limited only by sample scattering rates, with a prototype Pixel-array detector capable of taking two image frames separated by 153 ns or less. Although the overall frame rate is currently limited to about 4 frame pairs per second, we easily measured millisecond correlation functions. In conclusion, this technology, coupled to the use of brighter synchrotrons such as Petra III or the NSLS-II should enable X-ray Photon Correlation Spectroscopy on microsecond time scales on a wider variety of materials.
I spy with my little eye: cognitive processing of framed physical activity messages.
Bassett-Gunter, Rebecca L; Latimer-Cheung, Amy E; Martin Ginis, Kathleen A; Castelhano, Monica
2014-01-01
The primary purpose was to examine the relative cognitive processing of gain-framed versus loss-framed physical activity messages following exposure to health risk information. Guided by the Extended Parallel Process Model, the secondary purpose was to examine the relation between dwell time, message recall, and message-relevant thoughts, as well as perceived risk, personal relevance, and fear arousal. Baseline measures of perceived risk for inactivity-related disease and health problems were administered to 77 undergraduate students. Participants read population-specific health risk information while wearing a head-mounted eye tracker, which measured dwell time on message content. Perceived risk was then reassessed. Next, participants read PA messages while the eye tracker measured dwell time on message content. Immediately following message exposure, recall, thought-listing, fear arousal, and personal relevance were measured. Dwell time on gain-framed messages was significantly greater than loss-framed messages. However, message recall and thought-listing did not differ by message frame. Dwell time was not significantly related to recall or thought-listing. Consistent with the Extended Parallel Process Model, fear arousal was significantly related to recall, thought-listing, and personal relevance. In conclusion, gain-framed messages may evoke greater dwell time than loss-famed messages. However, dwell time alone may be insufficient for evoking further cognitive processing.
Time reversibility in the quantum frame
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masot-Conde, Fátima
2014-12-04
Classic Mechanics and Electromagnetism, conventionally taken as time-reversible, share the same concept of motion (either of mass or charge) as the basis of the time reversibility in their own fields. This paper focuses on the relationship between mobile geometry and motion reversibility. The goal is to extrapolate the conclusions to the quantum frame, where matter and radiation behave just as elementary mobiles. The possibility that the asymmetry of Time (Time’s arrow) is an effect of a fundamental quantum asymmetry of elementary particles, turns out to be a consequence of the discussion.
A framed, 16-image Kirkpatrick–Baez x-ray microscope
Marshall, F. J.; Bahr, R. E.; Goncharov, V. N.; ...
2017-09-08
A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2-more » to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.« less
A framed, 16-image Kirkpatrick–Baez x-ray microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marshall, F. J.; Bahr, R. E.; Goncharov, V. N.
A 16-image Kirkpatrick–Baez (KB)–type x-ray microscope consisting of compact KB mirrors has been assembled for the first time with mirrors aligned to allow it to be coupled to a high-speed framing camera. The high-speed framing camera has four independently gated strips whose emission sampling interval is ~30 ps. Images are arranged four to a strip with ~60-ps temporal spacing between frames on a strip. By spacing the timing of the strips, a frame spacing of ~15 ps is achieved. A framed resolution of ~6-um is achieved with this combination in a 400-um region of laser–plasma x-ray emission in the 2-more » to 8-keV energy range. A principal use of the microscope is to measure the evolution of the implosion stagnation region of cryogenic DT target implosions on the University of Rochester’s OMEGA Laser System. The unprecedented time and spatial resolution achieved with this framed, multi-image KB microscope have made it possible to accurately determine the cryogenic implosion core emission size and shape at the peak of stagnation. In conclusion, these core size measurements, taken in combination with those of ion temperature, neutron-production temporal width, and neutron yield allow for inference of core pressures, currently exceeding 50 GBar in OMEGA cryogenic target implosions.« less
42 CFR 93.505 - Rights of the parties.
Code of Federal Regulations, 2010 CFR
2010-10-01
... EFFECTS STUDIES OF HAZARDOUS SUBSTANCES RELEASES AND FACILITIES PUBLIC HEALTH SERVICE POLICIES ON RESEARCH..., proposed findings of fact and conclusions of law, and reply briefs within reasonable time frames agreed...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shepard, A; Bednarz, B
Purpose: To develop an ultrasound learning-based tracking algorithm with the potential to provide real-time motion traces of anatomy-based fiducials that may aid in the effective delivery of external beam radiation. Methods: The algorithm was developed in Matlab R2015a and consists of two main stages: reference frame selection, and localized block matching. Immediately following frame acquisition, a normalized cross-correlation (NCC) similarity metric is used to determine a reference frame most similar to the current frame from a series of training set images that were acquired during a pretreatment scan. Segmented features in the reference frame provide the basis for the localizedmore » block matching to determine the feature locations in the current frame. The boundary points of the reference frame segmentation are used as the initial locations for the block matching and NCC is used to find the most similar block in the current frame. The best matched block locations in the current frame comprise the updated feature boundary. The algorithm was tested using five features from two sets of ultrasound patient data obtained from MICCAI 2014 CLUST. Due to the lack of a training set associated with the image sequences, the first 200 frames of the image sets were considered a valid training set for preliminary testing, and tracking was performed over the remaining frames. Results: Tracking of the five vessel features resulted in an average tracking error of 1.21 mm relative to predefined annotations. The average analysis rate was 15.7 FPS with analysis for one of the two patients reaching real-time speeds. Computations were performed on an i5-3230M at 2.60 GHz. Conclusion: Preliminary tests show tracking errors comparable with similar algorithms at close to real-time speeds. Extension of the work onto a GPU platform has the potential to achieve real-time performance, making tracking for therapy applications a feasible option. This work is partially funded by NIH grant R01CA190298.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guckenberger, Matthias; Wilbert, Juergen; Krieger, Thomas
2009-06-01
Purpose: To evaluate the accuracy of direct reconstruction of mid-ventilation and peak-phase four-dimensional (4D) computed tomography (CT) frames based on the external breathing signal. Methods and Materials: For 11 patients with 15 pulmonary targets, a respiration-correlated CT study (4D CT) was acquired for treatment planning. After retrospective time-based sorting of raw projection data and reconstruction of eight CT frames equally distributed over the breathing cycle, mean tumor position (P{sub mean}), mid-ventilation frame, and breathing motion were evaluated based on the internal tumor trajectory. Analysis of the external breathing signal (pressure sensor around abdomen) with amplitude-based sorting of projections was performedmore » for direct reconstruction of the mid-ventilation frame and frames at peak phases of the breathing cycle. Results: On the basis of the eight 4D CT frames equally spaced in time, tumor motion was largest in the craniocaudal direction, with 12 {+-} 7 mm on average. Tumor motion between the two frames reconstructed at peak phases was not different in the craniocaudal and anterior-posterior directions but was systematically smaller in the left-right direction by 1 mm on average. The 3-dimensional distance between P{sub mean} and the tumor position in the mid-ventilation frame based on the internal tumor trajectory was 1.2 {+-} 1 mm. Reconstruction of the mid-ventilation frame at the mean amplitude position of the external breathing signal resulted in tumor positions 2.0 {+-} 1.1 mm distant from P{sub mean}. Breathing-induced motion artifacts in mid-ventilation frames caused negligible changes in tumor volume and shape. Conclusions: Direct reconstruction of the mid-ventilation frame and frames at peak phases based on the external breathing signal was reliable. This makes the reconstruction of only three 4D CT frames sufficient for application of the mid-ventilation technique in clinical practice.« less
Validity and reproducibility of self-reported working hours among Japanese male employees
Imai, Teppei; Kuwahara, Keisuke; Miyamoto, Toshiaki; Okazaki, Hiroko; Nishihara, Akiko; Kabe, Isamu; Mizoue, Tetsuya; Dohi, Seitaro
2016-01-01
Objective: Working long hours is a potential health hazard. Although self-reporting of working hours in various time frames has been used in epidemiologic studies, its validity is unclear. The objective of this study was to examine the validity and reproducibility of self-reported working hours among Japanese male employees. Methods: The participants were 164 male employees of four large-scale companies in Japan. For validity, the Spearman correlation between self-reported working hours in the second survey and the working hours recorded by the company was calculated for the following four time frames: daily working hours, monthly overtime working hours in the last month, average overtime working hours in the last 3 months, and the frequency of long working months (≥45 h/month) within the last 12 months. For reproducibility, the intraclass correlation between the first (September 2013) and second surveys (December 2013) was calculated for each of the four time frames. Results: The Spearman correlations between self-reported working hours and those based on company records were 0.74, 0.81, 0.85, and 0.89 for daily, monthly, 3-monthly, and yearly time periods, respectively. The intraclass correlations for self-reported working hours between the two questionnaire surveys were 0.63, 0.66, 0.73, and 0.87 for the respective time frames. Conclusions: The results of the present study among Japanese male employees suggest that the validity of self-reported working hours is high for all four time frames, whereas the reproducibility is moderate to high. PMID:27265530
Theory and Realization of Global Terrestrial Reference Systems
NASA Technical Reports Server (NTRS)
Ma, C.; Bolotin, S.; Gipson, J.; Gordon, D.; Le Bail, K.; MacMillan, D.
2010-01-01
Comparison of realizations of the terrestrial reference frame. IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We examined both results for VLBI sites using the full geodetic VLBI data set with respect to site positions and velocities and time series of station positions, baselines and Earth orientation parameters. One of the difficulties encountered was matching episodic breaks and periods of non-linear motion of the two realizations with the VLBI models. Our analysis and conclusions will be discussed.
Studies on the formation, temporal evolution and forensic applications of camera "fingerprints".
Kuppuswamy, R
2006-06-02
A series of experiments was conducted by exposing negative film in brand new cameras of different make and model. The exposures were repeated at regular time intervals spread over a period of 2 years. The processed film negatives were studied under a stereomicroscope (10-40x) in transmitted illumination for the presence of the characterizing features on their four frame-edges. These features were then related to those present on the masking frame of the cameras by examining the latter in reflected light stereomicroscopy (10-40x). The purpose of the study was to determine the origin and permanence of the frame-edge-marks, and also the processes by which the marks may probably alter with time. The investigations have arrived at the following conclusions: (i) the edge-marks have originated principally from the imperfections received on the film mask from the manufacturing and also occasionally from the accumulated dirt, dust and fiber on the film mask over an extended time period. (ii) The edge profiles of the cameras have remained fixed over a considerable period of time so as to be of a valuable identification medium. (iii) The marks are found to be varying in nature even with those cameras manufactured at similar time. (iv) The influence of f/number and object distance has great effect in the recording of the frame-edge marks during exposure of the film. The above findings would serve as a useful addition to the technique of camera edge-mark comparisons.
How Influenza Vaccination Policy May affect Vaccine Logistics
Assi, Tina-Marie; Rookkapan, Korngamon; Rajgopal, Jayant; Sornsrivichai, Vorasith; Brown, Shawn T.; Welling, Joel S.; Norman, Bryan A.; Connor, Diana L.; Chen, Sheng-I; Slayton, Rachel B.; Laosiritaworn, Yongjua; Wateska, Angela R.; Wisniewski, Stephen R.; Lee, Bruce Y.
2012-01-01
Background When policymakers make decision about the target populations and timing of influenza vaccination, they may not consider the impact on the vaccine supply chains, which may in turn affect vaccine availability. Purpose Our goal is to explore the effects on the Thailand vaccine supply chain of introducing influenza vaccines and varying the target populations and immunization time-frames. Methods Utilized our custom-designed software HERMES (Highly Extensible Resource for Modeling Supply Chains), we developed a detailed, computational discrete-event simulation model of the Thailand's National Immunization Program (NIP) supply chain in Trang Province, Thailand., A suite of experiments simulated introducing influenza vaccines for different target populations and over different time-frames prior to and during the annual influenza season. Results Introducing influenza vaccines creates bottlenecks that reduce the availability of both influenza vaccines as well as the other NIP vaccines, with provincial to district transport capacity being the primary constraint. Even covering only 25% of the Advisory Committee on Immunization Practice-recommended population while administering the vaccine over six months hinders overall vaccine availability so that only 62% of arriving patients can receive vaccines. Increasing the target population from 25% to 100% progressively worsens these bottlenecks, while increasing influenza vaccination time - frame from 1 to 6 months decreases these bottlenecks. Conclusion Since the choice of target populations for influenza vaccination and the time-frame to deliver this vaccine can substantially affect the flow of all vaccines, policy-makers may want to consider supply chain effects when choosing target populations for a vaccine. PMID:22537993
GPS-Only Terrestrial Reference Frame Based on a Global Reprocessing
NASA Astrophysics Data System (ADS)
Dietrich, R.; Rothacher, M.; Ruelke, A.; Fritsche, M.; Steigenberger, P.
2007-12-01
The realization of the International Terrestrial Reference System (ITRS) with highest accuracy and stability is fundamental and crucial for applications in geodesy, geodynamics, geophysics and global change. In a joint effort TU Dresden and TU Munich/GFZ Potsdam reprocessed a global GPS network of more than 200 stations. As a contribution to an ITRS realization daily normal equations from 1994 to 2005 were rigorously combined in order to determine a global GPS-only reference frame (PDR05/Potsdam-Dresden-Reprocessing Reference Frame). We present a realization of the global terrestrial reference system which follows the center of mass approach in consideration of the load-induced deformation of the Earth's crust due to the redistribution of surface masses. The stability of our reference frame will be evaluated based on the obtained long-term trends of station coordinates, the load-induced deformation estimates and the homogeneous time series of station positions. We will compare our solution with other recent terrestrial reference system realizations and give some conclusions for future realizations of the ITRS.
Video framerate, resolution and grayscale tradeoffs for undersea telemanipulator
NASA Technical Reports Server (NTRS)
Ranadive, V.; Sheridan, T. B.
1981-01-01
The product of Frame Rate (F) in frames per second, Resolution (R) in total pixels and grayscale in bits (G) equals the transmission band rate in bits per second. Thus for a fixed channel capacity there are tradeoffs between F, R and G in the actual sampling of the picture for a particular manual control task in the present case remote undersea manipulation. A manipulator was used in the MASTER/SLAVE mode to study these tradeoffs. Images were systematically degraded from 28 frames per second, 128 x 128 pixels and 16 levels (4 bits) grayscale, with various FRG combinations constructed from a real-time digitized (charge-injection) video camera. It was found that frame rate, resolution and grayscale could be independently reduced without preventing the operator from accomplishing his/her task. Threshold points were found beyond which degradation would prevent any successful performance. A general conclusion is that a well trained operator can perform familiar remote manipulator tasks with a considerably degrade picture, down to 50 K bits/ sec.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tseng, T; Sheu, R; Todorov, B
2014-06-15
Purpose: To evaluate initial setup accuracy for stereotactic radiosurgery (SRS) between Brainlab frame-based and frameless immobilization system, also to discern the magnitude frameless system has on setup parameters. Methods: The correction shifts from the original setup were compared for total 157 SRS cranial treatments (69 frame-based vs. 88 frameless). All treatments were performed on a Novalis linac with ExacTrac positioning system. Localization box with isocenter overlay was used for initial setup and correction shift was determined by ExacTrac 6D auto-fusion to achieve submillimeter accuracy for treatment. For frameless treatments, mean time interval between simulation and treatment was 5.7 days (rangemore » 0–13). Pearson Chi-Square was used for univariate analysis. Results: The correctional radial shifts (mean±STD, median) for the frame and frameless system measured by ExacTrac were 1.2±1.2mm, 1.1mm and 3.1±3.3mm, 2.0mm, respectively. Treatments with frameless system had a radial shift >2mm more often than those with frames (51.1% vs. 2.9%; p<.0001). To achieve submillimeter accuracy, 85.5% frame-based treatments did not require shift and only 23.9% frameless treatment could succeed with initial setup. There was no statistical significant system offset observed in any direction for either system. For frameless treatments, those treated ≥ 3 days from simulation had statistically higher rates of radial shifts between 1–2mm and >2mm compared to patients treated in a shorter amount of time from simulation (34.3% and 56.7% vs. 28.6% and 33.3%, respectively; p=0.006). Conclusion: Although image-guided positioning system can also achieve submillimeter accuracy for frameless system, users should be cautious regarding the inherent uncertainty of its capability of immobilization. A proper quality assurance procedure for frameless mask manufacturing and a protocol for intra-fraction imaging verification will be crucial for frameless system. Time interval between simulation and treatment was influential to initial setup accuracy. A shorter time frame for frameless SRS treatment could be helpful in minimizing uncertainties in localization.« less
Improved frame-based estimation of head motion in PET brain imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukherjee, J. M., E-mail: joyeeta.mitra@umassmed.edu; Lindsay, C.; King, M. A.
Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition ismore » uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.« less
Improved frame-based estimation of head motion in PET brain imaging
Mukherjee, J. M.; Lindsay, C.; Mukherjee, A.; Olivier, P.; Shao, L.; King, M. A.; Licho, R.
2016-01-01
Purpose: Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. Methods: The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. Results: The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. Conclusions: The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type. PMID:27147355
Solar/hydrogen systems for the 1985-2000 time frame - A review and assessment
NASA Technical Reports Server (NTRS)
Hanson, J. A.; Foster, R. W.; Escher, W. J. D.; Tison, R. R.
1982-01-01
A comprehensive state-of-the-art review of solar/hydrogen technologies has been conducted. From this, solar/hydrogen production systems which could be commercialized by the year 2000 have been characterized technically and economically. Incentives and disincentives for the early commercialization of four solar/hydrogen systems have been explored, conclusions drawn and recommendations made.
Knowledge Theory in Ibn Rushd Literature and Reflection Thereof on Its Educational Philosophy
ERIC Educational Resources Information Center
Al-Rsa'i, Mohammed
2018-01-01
This study aims to examine Ibn Rushd perceptions in terms of Knowledge and reflection thereof on his educational philosophy. This study reached at a conclusion that Ibn Rushd partaking had its important role in framing the Knowledge theory and maintain it away from deviations and in the same time originated much jurisprudences starting from…
Code of Federal Regulations, 2010 CFR
2010-07-01
... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 28 Judicial Administration 2 2014-07-01 2014-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 28 Judicial Administration 2 2012-07-01 2012-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 28 Judicial Administration 2 2011-07-01 2011-07-01 false Time-frames. 570.21 Section 570.21... PROGRAMS Pre-Release Community Confinement § 570.21 Time-frames. (a) Community confinement. Inmates may be... inmate's term of imprisonment or six months. (c) Exceeding time-frames. These time-frames may be exceeded...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazloom, M.
2008-07-08
The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquakemore » happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly.« less
Farnbacher, Michael J; Krause, Horst H; Hagel, Alexander F; Raithel, Martin; Neurath, Markus F; Schneider, Thomas
2014-03-01
OBJECTIVE. Colon capsule endoscopy (CCE) proved to be highly sensitive in detection of colorectal polyps (CP). Major limitation is the time-consuming video reading. The aim of this prospective, double-center study was to assess the theoretical time-saving potential and its possible impact on the reliability of "QuickView" (QV), in the presentation of CP as compared to normal mode (NM). METHODS. During NM reading of 65 CCE videos (mean patient´s age 56 years), all frames showing CPs were collected and compared to the number of frames presented by QV at increasing QV settings (10, 20, ... 80%). Reliability of QV in presenting polyps <6 mm and ≥6 mm (significant polyp), and identifying patients for subsequent therapeutic colonoscopy, capsule egestion rate, cleansing level, and estimated time-saving potential were assessed. RESULTS. At a 30% QV setting, the QV video presented 89% of the significant polyps and 86% of any polyps with ≥1 frame (per-polyp analysis) identified in NM before. At a 10% QV setting, 98% of the 52 patients with significant polyps could be identified (per-patient analysis) by QV video analysis. Capsule excretion rate was 74% and colon cleanliness was adequate in 85%. QV´s presentation rate correlates to the QV setting, the polyp size, and the number of frames per finding. CONCLUSIONS. Depending on its setting, the reliability of QV in presenting CP as compared to NM reading is notable. However, if no significant polyp is presented by QV, NM reading must be performed afterwards. The reduction of frames to be analyzed in QV might speed up identification of candidates for therapeutic colonoscopy.
12 CFR 516.190 - Will a meeting affect application processing time frames?
Code of Federal Regulations, 2010 CFR
2010-01-01
... time frames? 516.190 Section 516.190 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE... processing time frames? If OTS decides to conduct a meeting, it may suspend applicable application processing time frames, including the time frames for deeming an application complete and the applicable approval...
NASA Astrophysics Data System (ADS)
Heinkelmann, R.; Belda-Palazon, S.; Ferrándiz, J.; Schuh, H.
2015-08-01
For applications in Earth sciences, navigation, and astronomy the celestial (ICRF) and terrestrial (ITRF) reference frames as well as the orientation among them, the Earth orientation parameters (EOP), have to be consistent at the level of 1 mm and 0.1 mm/yr (GGOS recommendations). We assess the effect of unmodelled geophysical signals in the regularized coordinates and the sensitivity with respect to different a priori EOP and celestial reference frames. The EOP are determined using the same VLBI data but with station coordinates fixed on different TRFs. The conclusion is that within the time span of data incorporated into ITRF2008 (Altamimi, et al., 2011) the ITRF2008 and the IERS 08 C04 are consistent. This consistency involves that non-linear station motion such as unmodelled geophysical signals partly affect the IERS 08 C04 EOP. There are small but not negligible inconsistencies between the conventional celestial reference frame, ICRF2 (Fey, et al., 2009), the ITRF2008 and the conventional EOP that are quantified by comparing VTRF2008 (Böckmann, et al., 2010) and ITRF2008.
42 CFR 405.942 - Time frame for filing a request for a redetermination.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for filing a request for a...) Redeterminations § 405.942 Time frame for filing a request for a redetermination. (a) Time frame for filing a.... (b) Extending the time frame for filing a request. General rule. If the 120 calendar day period in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCowan, P. M., E-mail: pmccowan@cancercare.mb.ca; McCurdy, B. M. C.; Medical Physics Department, CancerCare Manitoba, 675 McDermot Avenue, Winnipeg, Manitoba R3E 0V9
Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, lessmore » EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.« less
2014-01-01
Background In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Methods Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Results Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. Conclusions The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia. PMID:25189826
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Time frames. 710.35 Section 710.35 Energy DEPARTMENT OF... Matter or Special Nuclear Material Miscellaneous § 710.35 Time frames. Statements of time established for processing aspects of a case under this subpart are the agency's desired time frames in implementing the...
The effects of the framing of time on delay discounting.
DeHart, William Brady; Odum, Amy L
2015-01-01
We examined the effects of the framing of time on delay discounting. Delay discounting is the process by which delayed outcomes are devalued as a function of time. Time in a titrating delay discounting task is often framed in calendar units (e.g., as 1 week, 1 month, etc.). When time is framed as a specific date, delayed outcomes are discounted less compared to the calendar format. Other forms of framing time; however, have not been explored. All participants completed a titrating calendar unit delay-discounting task for money. Participants were also assigned to one of two delay discounting tasks: time as dates (e.g., June 1st, 2015) or time in units of days (e.g., 5000 days), using the same delay distribution as the calendar delay-discounting task. Time framed as dates resulted in less discounting compared to the calendar method, whereas time framed as days resulted in greater discounting compared to the calendar method. The hyperboloid model fit best compared to the hyperbola and exponential models. How time is framed may alter how participants attend to the delays as well as how the delayed outcome is valued. Altering how time is framed may serve to improve adherence to goals with delayed outcomes. © Society for the Experimental Analysis of Behavior.
O’Keefe, Daniel J.; Wu, Daisy
2012-01-01
Persuading people to undertake actions to prevent skin cancer is an important public health challenge. A number of studies have compared the effectiveness of gain-framed and loss-framed appeals in this domain, often expecting gain-framed appeals to be more persuasive. A meta-analytic review (k = 33, N = 4,168), however, finds no significant difference in the persuasiveness of gain- and loss-framed appeals for encouraging skin cancer prevention. This conclusion is unaffected by differences in the specific protective action advocated or by differences in the kind of outcomes invoked. But the results offer an intimation that men might be more susceptible to framing variations in this domain—with loss-framed appeals potentially having a persuasive advantage. PMID:22829794
O'Keefe, Daniel J; Wu, Daisy
2012-06-01
Persuading people to undertake actions to prevent skin cancer is an important public health challenge. A number of studies have compared the effectiveness of gain-framed and loss-framed appeals in this domain, often expecting gain-framed appeals to be more persuasive. A meta-analytic review (k = 33, N = 4,168), however, finds no significant difference in the persuasiveness of gain- and loss-framed appeals for encouraging skin cancer prevention. This conclusion is unaffected by differences in the specific protective action advocated or by differences in the kind of outcomes invoked. But the results offer an intimation that men might be more susceptible to framing variations in this domain--with loss-framed appeals potentially having a persuasive advantage.
Thinking Fast Increases Framing Effects in Risky Decision Making.
Guo, Lisa; Trueblood, Jennifer S; Diederich, Adele
2017-04-01
Every day, people face snap decisions when time is a limiting factor. In addition, the way a problem is presented can influence people's choices, which creates what are known as framing effects. In this research, we explored how time pressure interacts with framing effects in risky decision making. Specifically, does time pressure strengthen or weaken framing effects? On one hand, research has suggested that framing effects evolve through the deliberation process, growing larger with time. On the other hand, dual-process theory attributes framing effects to an intuitive, emotional system that responds automatically to stimuli. In our experiments, participants made decisions about gambles framed in terms of either gains or losses, and time pressure was manipulated across blocks. Results showed increased framing effects under time pressure in both hypothetical and incentivized choices, which supports the dual-process hypothesis that these effects arise from a fast, intuitive system.
High-frame-rate infrared and visible cameras for test range instrumentation
NASA Astrophysics Data System (ADS)
Ambrose, Joseph G.; King, B.; Tower, John R.; Hughes, Gary W.; Levine, Peter A.; Villani, Thomas S.; Esposito, Benjamin J.; Davis, Timothy J.; O'Mara, K.; Sjursen, W.; McCaffrey, Nathaniel J.; Pantuso, Francis P.
1995-09-01
Field deployable, high frame rate camera systems have been developed to support the test and evaluation activities at the White Sands Missile Range. The infrared cameras employ a 640 by 480 format PtSi focal plane array (FPA). The visible cameras employ a 1024 by 1024 format backside illuminated CCD. The monolithic, MOS architecture of the PtSi FPA supports commandable frame rate, frame size, and integration time. The infrared cameras provide 3 - 5 micron thermal imaging in selectable modes from 30 Hz frame rate, 640 by 480 frame size, 33 ms integration time to 300 Hz frame rate, 133 by 142 frame size, 1 ms integration time. The infrared cameras employ a 500 mm, f/1.7 lens. Video outputs are 12-bit digital video and RS170 analog video with histogram-based contrast enhancement. The 1024 by 1024 format CCD has a 32-port, split-frame transfer architecture. The visible cameras exploit this architecture to provide selectable modes from 30 Hz frame rate, 1024 by 1024 frame size, 32 ms integration time to 300 Hz frame rate, 1024 by 1024 frame size (with 2:1 vertical binning), 0.5 ms integration time. The visible cameras employ a 500 mm, f/4 lens, with integration time controlled by an electro-optical shutter. Video outputs are RS170 analog video (512 by 480 pixels), and 12-bit digital video.
Chau, Josephine Y; Bonfiglioli, Catriona; Zhong, Amy; Pedisic, Zeljko; Daley, Michelle; McGill, Bronwyn; Bauman, Adrian
2017-08-01
Issue addressed This study examines how sedentary behaviour (too much sitting) was covered as a health issue by Australian newspapers and how physical activity was framed within this newspaper coverage. Methods Articles featuring sedentary behaviour published in Australian newspapers between 2000 and 2012 were analysed for content and framing. Main outcome measures were volume, number and content of newspaper articles; framing and types of sedentary behaviour; responsibility for the problem of and solutions to high levels of sedentary behaviour; and physical activity mentions and how it was framed within sedentary behaviour coverage. Results Out of 48 articles, prolonged sitting was framed as bad for health (52%) and specifically as health compromising for office workers (25%). Adults who sat a lot were framed as 'easy targets' for ill health (21% of headlines led with 'sitting ducks' or 'sitting targets'). Prolonged sitting was framed as an issue of individual responsibility (>90%) with less mention of environmental and sociocultural contributors. Thirty-six of 48 articles mentioned physical activity; 39% stated that being physically active does not matter if a person sits for prolonged periods of time or that the benefits of physical activity are undone by too much sitting. Conclusions News coverage should reflect the full socio-ecological model of sedentary behaviour and continually reinforce the independent and well-established benefits of health-enhancing physical activity alongside the need to limit prolonged sitting. So what? It is important that the entire 'move more, sit less, every day!' message is communicated by news media.
Fault-free behavior of reliable multiprocessor systems: FTMP experiments in AIRLAB
NASA Technical Reports Server (NTRS)
Clune, E.; Segall, Z.; Siewiorek, D.
1985-01-01
This report describes a set of experiments which were implemented on the Fault tolerant Multi-Processor (FTMP) at NASA/Langley's AIRLAB facility. These experiments are part of an effort to formulate and evaluate validation methodologies for fault-tolerant computers. This report deals with the measurement of single parameters (baselines) of a fault free system. The initial set of baseline experiments lead to the following conclusions: (1) The system clock is constant and independent of workload in the tested cases; (2) the instruction execution times are constant; (3) the R4 frame size is 40mS with some variation; (4) the frame stretching mechanism has some flaws in its implementation that allow the possibility of an infinite stretching of frame duration. Future experiments are planned. Some will broaden the results of these initial experiments. Others will measure the system more dynamically. The implementation of a synthetic workload generation mechanism for FTMP is planned to enhance the experimental environment of the system.
42 CFR 457.1160 - Program specific review process: Time frames.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 4 2010-10-01 2010-10-01 false Program specific review process: Time frames. 457... process: Time frames. (a) Eligibility or enrollment matter. A State must complete the review of a matter described in § 457.1130(a) within a reasonable amount of time. In setting time frames, the State must...
42 CFR 405.950 - Time frame for making a redetermination.
Code of Federal Regulations, 2010 CFR
2010-10-01
... decision-making time frame begins on the date the contractor receives the late-filed request for... filed, the contractor's 60 calendar day decision-making time frame is extended for up to 14 calendar... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for making a redetermination. 405.950...
Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery
Rottmann, Joerg; Keall, Paul; Berbeco, Ross
2013-01-01
Purpose: To provide real-time lung tumor motion estimation during radiotherapy treatment delivery without the need for implanted fiducial markers or additional imaging dose to the patient. Methods: 2D radiographs from the therapy beam's-eye-view (BEV) perspective are captured at a frame rate of 12.8 Hz with a frame grabber allowing direct RAM access to the image buffer. An in-house developed real-time soft tissue localization algorithm is utilized to calculate soft tissue displacement from these images in real-time. The system is tested with a Varian TX linear accelerator and an AS-1000 amorphous silicon electronic portal imaging device operating at a resolution of 512 × 384 pixels. The accuracy of the motion estimation is verified with a dynamic motion phantom. Clinical accuracy was tested on lung SBRT images acquired at 2 fps. Results: Real-time lung tumor motion estimation from BEV images without fiducial markers is successfully demonstrated. For the phantom study, a mean tracking error <1.0 mm [root mean square (rms) error of 0.3 mm] was observed. The tracking rms accuracy on BEV images from a lung SBRT patient (≈20 mm tumor motion range) is 1.0 mm. Conclusions: The authors demonstrate for the first time real-time markerless lung tumor motion estimation from BEV images alone. The described system can operate at a frame rate of 12.8 Hz and does not require prior knowledge to establish traceable landmarks for tracking on the fly. The authors show that the geometric accuracy is similar to (or better than) previously published markerless algorithms not operating in real-time. PMID:24007146
Abel, Taylor J; Varela Osorio, René; Amorim-Leite, Ricardo; Mathieu, Francois; Kahane, Philippe; Minotti, Lorella; Hoffmann, Dominique; Chabardes, Stephan
2018-04-20
OBJECTIVE Robot-assisted stereoelectroencephalography (SEEG) is gaining popularity as a technique for localization of the epileptogenic zone (EZ) in children with pharmacoresistant epilepsy. Here, the authors describe their frameless robot-assisted SEEG technique and report preliminary outcomes and relative complications in children as compared to results with the Talairach frame-based SEEG technique. METHODS The authors retrospectively analyzed the results of 19 robot-assisted SEEG electrode implantations in 17 consecutive children (age < 17 years) with pharmacoresistant epilepsy, and compared these results to 19 preceding SEEG electrode implantations in 18 children who underwent the traditional Talairach frame-based SEEG electrode implantation. The primary end points were seizure-freedom rates, operating time, and complication rates. RESULTS Seventeen children (age < 17 years) underwent a total of 19 robot-assisted SEEG electrode implantations. In total, 265 electrodes were implanted. Twelve children went on to have EZ resection: 4 demonstrated Engel class I outcomes, whereas 2 had Engel class II outcomes, and 6 had Engel class III-IV outcomes. Of the 5 patients who did not have resection, 2 underwent thermocoagulation. One child reported transient paresthesia associated with 2 small subdural hematomas, and 3 other children had minor asymptomatic intracranial hemorrhages. There were no differences in complication rates, rates of resective epilepsy surgery, or seizure freedom rates between this cohort and the preceding 18 children who underwent Talairach frame-based SEEG. The frameless robot-assisted technique was associated with shorter operating time (p < 0.05). CONCLUSIONS Frameless robot-assisted SEEG is a safe and effective means of identifying the EZ in children with pharmacoresistant partial epilepsy. Robot-assisted SEEG is faster than the Talairach frame-based method, and has equivalent safety and efficacy. The former, furthermore, facilitates more electrode trajectory possibilities, which may improve the localization of epileptic networks.
Electronic clinical predictive thermometer using logarithm for temperature prediction
NASA Technical Reports Server (NTRS)
Cambridge, Vivien J. (Inventor); Koger, Thomas L. (Inventor); Nail, William L. (Inventor); Diaz, Patrick (Inventor)
1998-01-01
A thermometer that rapidly predicts body temperature based on the temperature signals received from a temperature sensing probe when it comes into contact with the body. The logarithms of the differences between the temperature signals in a selected time frame are determined. A line is fit through the logarithms and the slope of the line is used as a system time constant in predicting the final temperature of the body. The time constant in conjunction with predetermined additional constants are used to compute the predicted temperature. Data quality in the time frame is monitored and if unacceptable, a different time frame of temperature signals is selected for use in prediction. The processor switches to a monitor mode if data quality over a limited number of time frames is unacceptable. Determining the start time on which the measurement time frame for prediction is based is performed by summing the second derivatives of temperature signals over time frames. When the sum of second derivatives in a particular time frame exceeds a threshold, the start time is established.
Kinematics of Laying an Automated Weapon System
2017-07-19
mathematical transformation is required to move the firing solution from its reference frame to a reference frame that is meaningful to the weapon system. This...Procedures 2 Conventions and Variable Definitions 2 Rotation Matrices 5 Transformation of a Vector 5 Conversion Between Cartestian and Spherical...Coordinate Systems 6 Transformation of Earth Referenced Lay to Platform Reference Frame 6 Results and Discussions 7 Conclusions 8 Bibliography 9
NASA Technical Reports Server (NTRS)
Howe, Dennis G.
1993-01-01
Just prior to its being EFM modulated (i.e., converted to eight-to-fourteen channel data by the EFM encoder) and written to a Compact Disc (CD), information that passes through the CIRC Block Encoder is grouped into 33-byte blocks referred to as EFM frames. Twenty four of the bytes that make up a given EFM frame are user data that was input into the CIRC encoder at various (different) times, 4 of the bytes of this same EFM frame were created by the C2 ECC encoder (each at a different time), and another 4 were created by the C1 ECC encoder (again, each at a different time). The one remaining byte of the given EFM frame, which is known as the EFM frame C&D (for Control & Display) byte, carries information that identifies which portion of the current disc program track the given EFM frame belongs to and also specifies the location of the given EFM frame on the disc (in terms of a time stamp that has a resolution of l/75th second, or 98 EFM frames). (Note: since the program track and time information is stored as a 98-byte word, a logical group consisting of 98 consecutive EFM frames must be read, and their respective C&D bytes must be catenated and decoded, before the program track identification and time position information that pertains to the entire block of 98 EFM frames can be obtained.) The C&D byte is put at the start (0th byte) of an EFM frame in real time; its placement completes the construction of the EFM frame - it is assigned just before the EFM frame enters the EFM encoder. Four distinct blocks of data are referred to: 24-byte User Input Data Blocks; 28-byte C2 words; 32-byte C1 words; and 33-byte EFM frames.
2010-01-01
Background Myxoma virus is a member of the Poxviridae and causes disease in European rabbits. Laboratory confirmation of the clinical disease, which occurs in the autumn of most years in Denmark, has been achieved previously using antigen ELISA and electron microscopy. Results An unusually large number of clinically suspected cases of myxomatosis were observed in Denmark during 2007. Myxoma virus DNA was detected, using a new real time PCR assay which targets the M029L gene, in over 70% of the clinical samples submitted for laboratory confirmation. Unexpectedly, further analysis revealed that a high proportion of these viral DNA preparations contained a frame-shift mutation within the M135R gene that has previously been identified as a virulence factor. This frame-shift mutation results in expression of a greatly truncated product. The same frame-shift mutation has also been found recently within an avirulent strain of myxoma virus (6918). However, three other frame-shift mutations found in this strain (in the genes M009L, M036L and M148R) were not shared with the Danish viruses but a single nucleotide deletion in the M138R/M139R intergenic region was a common feature. Conclusions It appears that expression of the full-length myxoma virus M135R protein is not required for virulence in rabbits. Hence, the frame-shift mutation in the M135R gene in the nonpathogenic 6918 virus strain is not sufficient to explain the attenuation of this myxoma virus but one/some of the other frame-shift mutations alone or in conjunction with one/some of the thirty two amino acid substitutions must also contribute. The real time PCR assay for myxoma virus is a useful diagnostic tool for laboratory confirmation of suspected cases of myxomatosis. PMID:20078890
TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belcher, AH; Liu, X; Wiersma, R
Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics roboticsmore » stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.« less
25 CFR 900.135 - May the time frames for action set out in this subpart be reduced?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 2 2010-04-01 2010-04-01 false May the time frames for action set out in this subpart be... EDUCATION ASSISTANCE ACT Construction § 900.135 May the time frames for action set out in this subpart be reduced? Yes. The time frames in this subpart are intended to be maximum times and may be reduced based on...
NASA Astrophysics Data System (ADS)
Dai, Yan
2018-04-01
With the increasing development of urban scale, the application of the underground frame structure is becoming more and more extensive. But because of the unreasonable setup, it hinders public transportation. Therefore, it is an effective solution to reinforce the underground frame structure and make it bear the traffic load. The simulation calculation of the reinforced underground frame structure is carried out in this paper. The conclusion is obtained that the structure satisfies the load of vehicle and the load of the crowd.
Return to sport following tibial plateau fractures: A systematic review
Robertson, Greg A J; Wong, Seng J; Wood, Alexander M
2017-01-01
AIM To systemically review all studies reporting return to sport following tibial plateau fracture, in order to provide information on return rates and times to sport, and to assess variations in sporting outcome for different treatment methods. METHODS A systematic search of CINAHAL, Cochrane, EMBASE, Google Scholar, MEDLINE, PEDro, Scopus, SPORTDiscus and Web of Science was performed in January 2017 using the keywords “tibial”, “plateau”, “fractures”, “knee”, “athletes”, “sports”, “non-operative”, “conservative”, “operative”, “return to sport”. All studies which recorded return rates and times to sport following tibial plateau fractures were included. RESULTS Twenty-seven studies were included: 1 was a randomised controlled trial, 7 were prospective cohort studies, 16 were retrospective cohort studies, 3 were case series. One study reported on the outcome of conservative management (n = 3); 27 reported on the outcome of surgical management (n = 917). Nine studies reported on Open Reduction Internal Fixation (ORIF) (n = 193), 11 on Arthroscopic-Assisted Reduction Internal Fixation (ARIF) (n = 253) and 7 on Frame-Assisted Fixation (FRAME) (n = 262). All studies recorded “return to sport” rates. Only one study recorded a “return to sport” time. The return rate to sport for the total cohort was 70%. For the conservatively-managed fractures, the return rate was 100%. For the surgically-managed fractures, the return rate was 70%. For fractures managed with ORIF, the return rate was 60%. For fractures managed with ARIF, the return rate was 83%. For fractures managed with FRAME was 52%. The return rate for ARIF was found to be significantly greater than that for ORIF (OR 3.22, 95%CI: 2.09-4.97, P < 0.001) and for FRAME (OR 4.33, 95%CI: 2.89-6.50, P < 0.001). No difference was found between the return rates for ORIF and FRAME (OR 1.35, 95%CI: 0.92-1.96, P = 0.122). The recorded return time was 6.9 mo (median), from a study reporting on ORIF. CONCLUSION Return rates to sport for tibial plateau fractures remain limited compared to other fractures. ARIF provides the best return rates. There is limited data regarding return times to sport. Further research is required to determine return times to sport, and to improve return rates to sport, through treatment and rehabilitation optimisation. PMID:28808629
Zhao, Xiaoquan; Villagran, Melinda M; Kreps, Gary L; McHorney, Colleen
2012-01-01
This study investigated the joint effect of message framing and time perspective in adherence-promoting communication targeting patients with chronic diseases. Based on previous framing and time perspective research, it was hypothesized that the gain frame would show an advantage over the loss frame among future-oriented patients; for present-oriented patients, it was hypothesized that the framing effect would be relatively indistinct. In total, 1,108 currently nonadherent patients with chronic disease participated in an experiment where they were randomly assigned to either gain- or loss-framed messages addressing key beliefs underlying their nonadherence or a no-message control condition. Intention and attitude regarding future adherence as well as message perceptions were measured after message presentation. Results of this study generally supported the hypotheses. Message topics-whether the messages addressed patients' perceived need for medications or concerns about side effects-did not moderate the effect of framing or the interaction between framing and time perspective. Theoretical and practical implications are discussed.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false What are the applicable time frames and procedures... and Processing § 286.160 What are the applicable time frames and procedures for submitting a Tribal... Secretary according to the following time frames: Implementation date: Letter of intent due to ACF and the...
A transform from absorption to Raman excitation profile. A time-dependent approach
NASA Astrophysics Data System (ADS)
Lee, Soo-Y.; Yeo, Robert C. K.
1994-04-01
An alternative time-frame approach, which is canonically conjugate to the energy-frame approach, for implementing the transform relations for calculating Raman excitation profiles directly from the optical absorption spectrum is presented. Practical and efficient fast Fourier transformation in the time frame replaces the widely used Chan and Page algorithm for evaluating the Hilbert transform in the energy frame. The time-frame approach is applied to: (a) a two-mode model which illustrates the missing mode effect in both absorption and Raman excitation profiles, (b) carotene, in which both the absorption spectrum and the Raman excitation profile show vibrational structure and (c) hexamethylbenzene: TCNE electron donor—acceptor complex where the same spectra are structureless and the Raman excitation profile for the 168 cm -1 mode poses a problem for the energy-frame approach. A similar time-frame approach can be used for the inverse transform from the Raman excitation profile to the optical absorption spectrum.
O'Keefe, Daniel J; Nan, Xiaoli
2012-01-01
Vaccination against disease is a powerful public health tool, and persuading people to be vaccinated is a correspondingly important challenge. A number of studies have compared the effectiveness of gain-framed and loss-framed appeals in this domain, often expecting gain-framed appeals to be more persuasive. A meta-analytic review (k = 32, N = 11,814), however, finds no significant difference in the persuasiveness of gain- and loss-framed appeals for encouraging vaccination. This conclusion is unaffected by differences in the phrasing of the outcomes invoked or by differences in the specific vaccination advocated. But the results contain a hint that parents might be more persuaded to vaccinate their children by loss-framed than by gain-framed appeals. Implications and directions for future research are discussed.
NASA Technical Reports Server (NTRS)
Deines, Steven D.
1992-01-01
Relativity compensations must be made in precise and accurate measurements whenever an observer is accelerated. Although many believe the Earth-centered frame is sufficiently inertial, accelerations of the Earth, as evidenced by the tides, prove that it is technically a noninertial system for even an Earth-based observer. Using the constant speed of light, a set of fixed remote clocks in an inertial frame can be synchronized to a fixed master clock transmitting its time in that frame. The time on the remote clock defines the coordinate time at that coordinate position. However, the synchronization procedure for an accelerated frame is affected, because the distance between the master and remote clocks is altered due to the acceleration of the remote clock toward or away from the master clock during the transmission interval. An exact metric that converts observations from noninertial frames to inertial frames was recently derived. Using this metric with other physical relationships, a new concept of noninertial coordinate time is defined. This noninertial coordinate time includes all relativity compensations. This new issue raises several timekeeping issues, such as proper time standards, time transfer process, and clock synchronization, all in a noninertial frame such as Earth.
O'Malley, Deborah A; Latimer-Cheung, Amy E
2013-11-01
This study examined how framed messages affect viewer attention to and cognitive processing of osteoporosis prevention print ads. Attention was measured with eye tracking technology. Cognitive processing was assessed through masked recall. A total of 60 college-aged women viewed 12 gain-framed, 12 loss-framed, and 12 neutral-framed ads. Number of fixations, dwell time, and recall of gain-framed osteoporosis prevention ads were higher than loss-framed or neutral-framed ads, p < .01. Message recall was positively correlated with the number of fixations and dwell time for the gain-framed and neutral-framed messages, p < .01. These findings provide preliminary insight into potential mechanisms underlying message framing effects.
Podkowinski, Dominika; Sharian Varnousfaderani, Ehsan; Simader, Christian; Bogunovic, Hrvoje; Philip, Ana-Maria; Gerendas, Bianca S.
2017-01-01
Background and Objective To determine optimal image averaging settings for Spectralis optical coherence tomography (OCT) in patients with and without cataract. Study Design/Material and Methods In a prospective study, the eyes were imaged before and after cataract surgery using seven different image averaging settings. Image quality was quantitatively evaluated using signal-to-noise ratio, distinction between retinal layer image intensity distributions, and retinal layer segmentation performance. Measures were compared pre- and postoperatively across different degrees of averaging. Results 13 eyes of 13 patients were included and 1092 layer boundaries analyzed. Preoperatively, increasing image averaging led to a logarithmic growth in all image quality measures up to 96 frames. Postoperatively, increasing averaging beyond 16 images resulted in a plateau without further benefits to image quality. Averaging 16 frames postoperatively provided comparable image quality to 96 frames preoperatively. Conclusion In patients with clear media, averaging 16 images provided optimal signal quality. A further increase in averaging was only beneficial in the eyes with senile cataract. However, prolonged acquisition time and possible loss of details have to be taken into account. PMID:28630764
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konstantinidis, Anastasios C.; Olivo, Alessandro; Speller, Robert D.
2011-12-15
Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat framesmore » used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.« less
Rönnlund, Michael; Karlsson, Erik; Laggnäs, Erica; Larsson, Lisa; Lindström, Therese
2005-01-01
In the present study, the authors investigated the effects of framing of options on risky decision making in groups of younger adults (M = 23.8 years, n = 192) and older adults (M = 69.1 years, n = 192). The participants were assigned to one of three scenarios varying in the goods at stake (human lives, paintings, money). The authors observed a majority preference in favor of the risky options after negative, but not positive framing. They also found, as they had predicted, that the type of framing effect varied across scenarios, with a bidirectional framing effect for the life-death scenario and unidirectional (risk averse) framing effects when public property (paintings) or personal property (money) were at stake. It is important to note that these choice preference patterns were highly similar across the age groups, which reinforced the conclusion that younger and older adults are equally susceptible to framing effects.
Konrad, Peter E.; Neimat, Joseph S.; Yu, Hong; Kao, Chris C.; Remple, Michael S.; D'Haese, Pierre-François; Dawant, Benoit M.
2011-01-01
Background The microTargeting™ platform (MTP) stereotaxy system (FHC Inc., Bowdoin, Me., USA) was FDA approved in 2001 utilizing rapid-prototyping technology to create custom platforms for human stereotaxy procedures. It has also been called the STarFix (surgical targeting fixture) system since it is based on the concept of a patient- and procedure-specific surgical fixture. This is an alternative stereotactic method by which planned trajectories are incorporated into custom-built, miniature stereotactic platforms mounted onto bone fiducial markers. Our goal is to report the clinical experience with this system over a 6-year period. Methods We present the largest reported series of patients who underwent deep brain stimulation (DBS) implantations using customized rapidly prototyped stereotactic frames (MTP). Clinical experience and technical features for the use of this stereotactic system are described. Final lead location analysis using postoperative CT was performed to measure the clinical accuracy of the stereotactic system. Results Our series included 263 patients who underwent 284 DBS implantation surgeries at one institution over a 6-year period. The clinical targeting error without accounting for brain shift in this series was found to be 1.99 mm (SD 0.9). Operating room time was reduced through earlier incision time by 2 h per case. Conclusion Customized, miniature stereotactic frames, namely STarFix platforms, are an acceptable and efficient alternative method for DBS implantation. Its clinical accuracy and outcome are comparable to those associated with traditional stereotactic frame systems. PMID:21160241
Evaluation of Long Term Performance of Continuously Running Atomic Fountains
2014-05-28
at least on the time frame of the accuracy evaluations. For example, the PTB has produced an excellent timescale based on a single caesium fountain...at PTB , which are beam standards. Figure 7. Relative frequency of NRF5 and each caesium fountain measurement reported to TAI. The (three) fountains...at LNE-SYRTE and (the two) at PTB are differentiated from the other labs reporting (NIST, NPL and one report from NICT). 6. Conclusion To summarize
Pilkonis, Paul A.; Yu, Lan; Dodds, Nathan E.; Johnston, Kelly L.; Lawrence, Suzanne; Hilton, Thomas F.; Daley, Dennis C.; Patkar, Ashwin A.; McCarty, Dennis
2015-01-01
Background Two item banks for substance use were developed as part of the Patient-Reported Outcomes Measurement Information System (PROMIS®): severity of substance use and positive appeal of substance use. Methods Qualitative item analysis (including focus groups, cognitive interviewing, expert review, and item revision) reduced an initial pool of more than 5,300 items for substance use to 119 items included in field testing. Items were written in a first-person, past-tense format, with 5 response options reflecting frequency or severity. Both 30-day and 3-month time frames were tested. The calibration sample of 1,336 respondents included 875 individuals from the general population (ascertained through an internet panel) and 461patients from addiction treatment centers participating in the National Drug Abuse Treatment Clinical Trials Network. Results Final banks of 37 and 18 items were calibrated for severity of substance use and positive appeal of substance use, respectively, using the two-parameter graded response model from item response theory (IRT). Initial calibrations were similar for the 30-day and 3-month time frames, and final calibrations used data combined across the time frames, making the items applicable with either interval. Seven-item static short forms were also developed from each item bank. Conclusions Test information curves showed that the PROMIS item banks provided substantial information in a broad range of severity, making them suitable for treatment, observational, and epidemiological research in both clinical and community settings. PMID:26423364
Solid-state framing camera with multiple time frames
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baker, K. L.; Stewart, R. E.; Steele, P. T.
2013-10-07
A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.
39 CFR 775.12 - Time frames for environmental impact statement actions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Time frames for environmental impact statement... NATIONAL ENVIRONMENTAL POLICY ACT PROCEDURES § 775.12 Time frames for environmental impact statement... environmental impact statements received in that office during the preceding week. The minimum time periods for...
Chen, Chieh-Li; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Schuman, Joel S.
2016-01-01
Purpose Developing a novel image enhancement method so that nonframe-averaged optical coherence tomography (OCT) images become comparable to active eye-tracking frame-averaged OCT images. Methods Twenty-one eyes of 21 healthy volunteers were scanned with noneye-tracking nonframe-averaged OCT device and active eye-tracking frame-averaged OCT device. Virtual averaging was applied to nonframe-averaged images with voxel resampling and adding amplitude deviation with 15-time repetitions. Signal-to-noise (SNR), contrast-to-noise ratios (CNR), and the distance between the end of visible nasal retinal nerve fiber layer (RNFL) and the foveola were assessed to evaluate the image enhancement effect and retinal layer visibility. Retinal thicknesses before and after processing were also measured. Results All virtual-averaged nonframe-averaged images showed notable improvement and clear resemblance to active eye-tracking frame-averaged images. Signal-to-noise and CNR were significantly improved (SNR: 30.5 vs. 47.6 dB, CNR: 4.4 vs. 6.4 dB, original versus processed, P < 0.0001, paired t-test). The distance between the end of visible nasal RNFL and the foveola was significantly different before (681.4 vs. 446.5 μm, Cirrus versus Spectralis, P < 0.0001) but not after processing (442.9 vs. 446.5 μm, P = 0.76). Sectoral macular total retinal and circumpapillary RNFL thicknesses showed systematic differences between Cirrus and Spectralis that became not significant after processing. Conclusion The virtual averaging method successfully improved nontracking nonframe-averaged OCT image quality and made the images comparable to active eye-tracking frame-averaged OCT images. Translational Relevance Virtual averaging may enable detailed retinal structure studies on images acquired using a mixture of nonframe-averaged and frame-averaged OCT devices without concerning about systematic differences in both qualitative and quantitative aspects. PMID:26835180
Coincidence ion imaging with a fast frame camera
NASA Astrophysics Data System (ADS)
Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen
2014-12-01
A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.
Toward the greening of nuclear energy: A content analysis of nuclear energy frames from 1991 to 2008
NASA Astrophysics Data System (ADS)
Miller, Sonya R.
Framing theory has emerged as one of the predominant theories employed in mass communications research in the 21st century. Frames are identified as interpretive packages for content where some issue attributes are highlighted over other attributes. While framing effects studies appear plentiful, longitudinal studies assessing trends in dominant framing packages and story elements for an issue appear to be less understood. Through content analysis, this study examines dominant frame packages, story elements, headline tone, story tone, stereotypes, and source attribution for nuclear energy from 1991-2008 in the New York Times, USA Today, the Wall Street Journal, and the Washington Post. Unlike many content analysis studies, this study compares intercoder reliability among three indices---percentage agreement, proportional reduction of loss and Scott's Pi. The newspapers represented in this study possess a commonality in the types of dominant frames packages employed. Significant dominant frame packages among the four newspapers include human/health, proliferation, procedural, and marketplace. While the procedural frame package was more likely to appear prior to the 1997 Kyoto Protocol, the proliferation frame packaged was more likely to appear after the Kyoto Protol. Over time, the sustainable frame package demonstrated increased significance. This study is part of the growing literature regarding the function of frames over time.
Nanosurveyor: a framework for real-time data processing
Daurer, Benedikt J.; Krishnan, Hari; Perciano, Talita; ...
2017-01-31
Background: The ever improving brightness of accelerator based sources is enabling novel observations and discoveries with faster frame rates, larger fields of view, higher resolution, and higher dimensionality. Results: Here we present an integrated software/algorithmic framework designed to capitalize on high-throughput experiments through efficient kernels, load-balanced workflows, which are scalable in design. We describe the streamlined processing pipeline of ptychography data analysis. Conclusions: The pipeline provides throughput, compression, and resolution as well as rapid feedback to the microscope operators.
2015-02-01
producing cracking, in a time frame on the order of weeks. The hypothesized mechanism is syneresis, involving the sorption of the surfactants from...49 4.0 Determination of Mechanism of Clay Structure Modification 53 ii 4.1 Introduction 53 4.2 Materials and Methods 52 4.2.1. Screening...Spectroscopy (FTIR) Measurements 65 4.3.4. Sorption Experiments 68 4.4 Proposed Mechanism for Basal Spacing Decrease 70 4.5 Conclusions 72 5.0
Role of "the frame cycle time" in portal dose imaging using an aS500-II EPID.
Al Kattar Elbalaa, Zeina; Foulquier, Jean Noel; Orthuon, Alexandre; Elbalaa, Hanna; Touboul, Emmanuel
2009-09-01
This paper evaluates the role of an acquisition parameter, the frame cycle time "FCT", in the performance of an aS500-II EPID. The work presented rests on the study of the Varian EPID aS500-II and the image acquisition system 3 (IAS3). We are interested in integrated acquisition using asynchronous mode. For better understanding the image acquisition operation, we investigated the influence of the "frame cycle time" on the speed of acquisition, the pixel value of the averaged gray-scale frame and the noise, using 6 and 15MV X-ray beams and dose rates of 1-6Gy/min on 2100 C/D Linacs. In the integrated mode not synchronized to beam pulses, only one parameter the frame cycle time "FCT" influences the pixel value. The pixel value of the averaged gray-scale frame is proportional to this parameter. When the FCT <55ms (speed of acquisition V(f/s)>18 frames/s), the speed of acquisition becomes unstable and leads to a fluctuation of the portal dose response. A timing instability and saturation are detected when the dose per frame exceeds 1.53MU/frame. Rules were deduced to avoid saturation and to optimize this dosimetric mode. The choice of the acquisition parameter is essential for the accurate portal dose imaging.
40 CFR 35.110 - Time frame for EPA action.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Time frame for EPA action. 35.110... ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants Epa Action on Application § 35.110 Time frame for EPA action. The Regional Administrator will review a complete application and either approve...
40 CFR 35.105 - Time frame for submitting an application.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for submitting an application. 35.105 Section 35.105 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER....105 Time frame for submitting an application. An applicant should submit a complete application to EPA...
42 CFR 405.922 - Time frame for processing initial determinations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Time frame for processing initial determinations. 405.922 Section 405.922 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... § 405.922 Time frame for processing initial determinations. The contractor issues initial determinations...
40 CFR 35.506 - Time frame for submitting an application.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for submitting an application. 35.506 Section 35.506 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER... Application § 35.506 Time frame for submitting an application. An applicant should submit a complete...
40 CFR 35.510 - Time frame for EPA action.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...
40 CFR 35.510 - Time frame for EPA action.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...
40 CFR 35.510 - Time frame for EPA action.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Time frame for EPA action. 35.510 Section 35.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL....510 Time frame for EPA action. The Regional Administrator will review a complete application and...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-01
... times for those actions. This AD was prompted by reports of cracking in the frame, or in the frame and frame reinforcement, common to the 1.04- inch nominal diameter wire penetration hole intended for wire routing; and recent reports of multiple adjacent frame cracking found before the compliance time required...
2012-01-01
Background Legislating restrictions on alcohol advertising is a cost-effective measure to reduce consumption of alcohol. Yet Australia relies upon industry self-regulation through voluntary codes of practice regarding the content, timing and placement of alcohol advertising. Ending industry self-regulation was recommended by the National Preventative Health Taskforce; a suggestion contested by the drinks industry. Debates about emerging alcohol-control policies regularly play out in the news media, with various groups seeking to influence the discussion. This paper examines news coverage of recommendations to restrict alcohol advertising to see how supporters and opponents frame the debate, with a view to providing some suggestions for policy advocates to advance the discussion. Methods We used content and framing analyses to examine 329 Australian newspaper items mentioning alcohol advertising restrictions over 24 months. All items were coded for mentions of specific types of advertising and types of advertising restrictions, the presence of news frames that opposed or endorsed advertising restrictions, statements made within each frame and the news-actors who appeared. Results Restrictions were the main focus in only 36% of 329 items. Alcohol advertising was conceived of as television (47%) and sport-related (56%). Restrictions were mentioned in non-specific terms (45%), or specified as restrictions on timing and placement (49%), or content (22%). Public health professionals (47%) appeared more frequently than drinks industry representatives (18%). Five supportive news frames suggested the policy is a sensible public health response, essential to protect children, needed to combat the drinks industry, required to stop pervasive branding, or as only an issue in sport. Four unsupportive frames positioned restrictions as unnecessary for a responsible industry, an attack on legitimate commercial activities, ineffective and ‘nannyist’, or inessential to government policy. Support varied among news-actors, with public health professionals (94%) more supportive than the public (68%), community-based organisations (76%), the government (72%), and the sports (16%), drinks (3%), or advertising (4%) industries. Conclusion Restrictions on alcohol advertising currently have low newsworthiness as a standalone issue. Future advocacy might better define the exact nature of required restrictions, anticipate vocal opposition and address forms of advertising beyond televised sport if exposure to advertising, especially among children, is to be reduced. PMID:22938674
Evaluating the Human Damage of Tsunami at Each Time Frame in Aggregate Units Based on GPS data
NASA Astrophysics Data System (ADS)
Ogawa, Y.; Akiyama, Y.; Kanasugi, H.; Shibasaki, R.; Kaneda, H.
2016-06-01
Assessments of the human damage caused by the tsunami are required in order to consider disaster prevention at such a regional level. Hence, there is an increasing need for the assessments of human damage caused by earthquakes. However, damage assessments in japan currently usually rely on static population distribution data, such as statistical night time population data obtained from national census surveys. Therefore, human damage estimation that take into consideration time frames have not been assessed yet. With these backgrounds, the objectives of this study are: to develop a method for estimating the population distribution of the for each time frame, based on location positioning data observed with mass GPS loggers of mobile phones, to use a evacuation and casualties models for evaluating human damage due to the tsunami, and evaluate each time frame by using the data developed in the first objective, and 3) to discuss the factors which cause the differences in human damage for each time frame. By visualizing the results, we clarified the differences in damage depending on time frame, day and area. As this study enables us to assess damage for any time frame in and high resolution, it will be useful to consider provision for various situations when an earthquake may hit, such as during commuting hours or working hours and week day or holiday.
Results from the JPL IGS Analysis Center IGS14 Reprocessing Campaign
NASA Astrophysics Data System (ADS)
Ries, P. A.; Amiri, N.; Heflin, M. B.; Sakumura, C.; Sibois, A. E.; Sibthorpe, A.; David, M. W.
2017-12-01
The JPL IGS analysis center has begun a campaign to reprocess GPS orbits and clocks in the IGS14 reference frame. Though the new frame is only a few millimeters offset from the previous IGb08 frame, a reprocessing is required for consistent use of the new frame due to a change in the satellite phase center offsets between the frames. We will present results on the reprocessing campaign from 2002 to present in order to evaluate any effects caused by the new frame. We also create long-term time-series and periodograms of translation, rotation, and scale parameters to see if there is any divergence between the frames. We will also process long-term PPP time series and derived velocities for a well-distributed set of stations in each frame to compare with the published frame offsets.
Hardware accelerator design for tracking in smart camera
NASA Astrophysics Data System (ADS)
Singh, Sanjay; Dunga, Srinivasa Murali; Saini, Ravi; Mandal, A. S.; Shekhar, Chandra; Vohra, Anil
2011-10-01
Smart Cameras are important components in video analysis. For video analysis, smart cameras needs to detect interesting moving objects, track such objects from frame to frame, and perform analysis of object track in real time. Therefore, the use of real-time tracking is prominent in smart cameras. The software implementation of tracking algorithm on a general purpose processor (like PowerPC) could achieve low frame rate far from real-time requirements. This paper presents the SIMD approach based hardware accelerator designed for real-time tracking of objects in a scene. The system is designed and simulated using VHDL and implemented on Xilinx XUP Virtex-IIPro FPGA. Resulted frame rate is 30 frames per second for 250x200 resolution video in gray scale.
Benioff, Paul
2009-01-01
Tmore » his work is based on the field of reference frames based on quantum representations of real and complex numbers described in other work. Here frame domains are expanded to include space and time lattices. Strings of qukits are described as hybrid systems as they are both mathematical and physical systems. As mathematical systems they represent numbers. As physical systems in each frame the strings have a discrete Schrodinger dynamics on the lattices. he frame field has an iterative structure such that the contents of a stage j frame have images in a stage j - 1 (parent) frame. A discussion of parent frame images includes the proposal that points of stage j frame lattices have images as hybrid systems in parent frames. he resulting association of energy with images of lattice point locations, as hybrid systems states, is discussed. Representations and images of other physical systems in the different frames are also described.« less
78 FR 46528 - Surety Bond Guarantee Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-01
... proposing to reduce the time frame allowed for a Surety to reimburse or credit SBA for salvage and recovery... the time frame reference required by the Recovery Act, which has expired, and by inserting the...)(1). SBA is proposing to reduce the time frame allowed for a Prior Approval Surety to submit a claim...
5 CFR 890.807 - When do enrollments terminate, cancel or suspend?
Code of Federal Regulations, 2010 CFR
2010-01-01
... on whose service the health benefits are based. (2) OPM may authorize a longer time frame for the...) Termination of enrollment for failure to pay premiums within the time frame established in accordance with... the enrollment of a former spouse who fails to make an election within the specified time frame will...
21 CFR 60.28 - Time frame for determining regulatory review periods.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Time frame for determining regulatory review periods. 60.28 Section 60.28 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PATENT TERM RESTORATION Regulatory Review Period Determinations § 60.28 Time frame for...
42 CFR 403.251 - Loss ratio date and time frame provisions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Loss ratio date and time frame provisions. 403.251 Section 403.251 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... Certification Program: Loss Ratio Provisions § 403.251 Loss ratio date and time frame provisions. (a) Initial...
Coincidence ion imaging with a fast frame camera
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei
2014-12-15
A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots onmore » each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.« less
Study on the effect of the infill walls on the seismic performance of a reinforced concrete frame
NASA Astrophysics Data System (ADS)
Zhang, Cuiqiang; Zhou, Ying; Zhou, Deyuan; Lu, Xilin
2011-12-01
Motivated by the seismic damage observed to reinforced concrete (RC) frame structures during the Wenchuan earthquake, the effect of infill walls on the seismic performance of a RC frame is studied in this paper. Infill walls, especially those made of masonry, offer some amount of stiffness and strength. Therefore, the effect of infill walls should be considered during the design of RC frames. In this study, an analysis of the recorded ground motion in the Wenchuan earthquake is performed. Then, a numerical model is developed to simulate the infill walls. Finally, nonlinear dynamic analysis is carried out on a RC frame with and without infill walls, respectively, by using CANNY software. Through a comparative analysis, the following conclusions can be drawn. The failure mode of the frame with infill walls is in accordance with the seismic damage failure pattern, which is strong beam and weak column mode. This indicates that the infill walls change the failure pattern of the frame, and it is necessary to consider them in the seismic design of the RC frame. The numerical model presented in this paper can effectively simulate the effect of infill walls on the RC frame.
Coincidence electron/ion imaging with a fast frame camera
NASA Astrophysics Data System (ADS)
Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin
2015-05-01
A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false What time frames and guidelines apply regarding... NEW Program Funding § 287.55 What time frames and guidelines apply regarding the obligation and... be returned to the Federal government through the issuance of a negative grant award. Unobligated...
26 CFR 301.6343-1 - Requirement to release levy and notice of release.
Code of Federal Regulations, 2010 CFR
2010-04-01
... expedited determination, the taxpayer must submit, within the time frame specified in paragraph (c)(2) of... cases where a request for release of a levy is made within the time frame specified in paragraph (c)(2... time frame specified in paragraph (c)(2) of this section, the information required in paragraph (c)(1...
20 CFR 30.421 - What are the time frames for submitting bills and reimbursement requests?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false What are the time frames for submitting bills and reimbursement requests? 30.421 Section 30.421 Employees' Benefits OFFICE OF WORKERS' COMPENSATION... AMENDED Medical and Related Benefits Medical Bills § 30.421 What are the time frames for submitting bills...
20 CFR 10.336 - What are the time frames for submitting bills?
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false What are the time frames for submitting bills? 10.336 Section 10.336 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF...' COMPENSATION ACT, AS AMENDED Medical and Related Benefits Medical Bills § 10.336 What are the time frames for...
Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children
Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew
2015-01-01
Objective To compare three variants of a culturally-relevant and theoretically-based message to determine the most influential risk framing approach for improving intention to place dental sealants for preschool children. Design and Sample A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. Measurements We compared participant's scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. Results The mean difference in participant's stage-of-change scores (x = 1.17, n = 89, sd = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t(88) = 5.81, p < .0001, 95% CI [0.77 – 1.57]. Self-efficacy was the only construct for which we detected a statistically significant difference as a function of frame assignment. Overall, the mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Conclusions Community advisory board members determined to use the mix-framed approach in an oral-health social marketing campaign with a rural, American Indian audience. PMID:26032902
Mobasheri, Saeedeh; Behnam, Hamid; Rangraz, Parisa; Tavakkoli, Jahan
2016-01-01
High-intensity focused ultrasound (HIFU) is a novel treatment modality used by scientists and clinicians in the recent decades. This modality has had a great and significant success as a noninvasive surgery technique applicable in tissue ablation therapy and cancer treatment. In this study, radio frequency (RF) ultrasound signals were acquired and registered in three stages of before, during, and after HIFU exposures. Different features of RF time series signals including the sum of amplitude spectrum in the four quarters of the frequency range, the slope, and intercept of the best-fit line to the entire power spectrum and the Shannon entropy were utilized to distinguish between the HIFU-induced thermal lesion and the normal tissue. We also examined the RF data, frame by frame to identify exposure effects on the formation and characteristics of a HIFU thermal lesion at different time steps throughout the treatment. The results obtained showed that the spectrum frequency quarters and the slope and intercept of the best fit line to the entire power spectrum both increased two times during the HIFU exposures. The Shannon entropy, however, decreased after the exposures. In conclusion, different characteristics of RF time series signal possess promising features that can be used to characterize ablated and nonablated tissues and to distinguish them from each other in a quasi-quantitative fashion.
Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S
2015-01-01
Purpose MRI-guided interventions demand high frame-rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Methods Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real-time to interactively de-blur spiral images. Results Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 minutes of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. Conclusions This real-time distortion correction framework will enable the use of these high frame-rate imaging methods for MRI-guided interventions. PMID:26114951
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What are the time frames under which States submit performance progress reports and apply for incentive grants? 666.205 Section 666.205 Employees... the time frames under which States submit performance progress reports and apply for incentive grants...
Improved quality of intrafraction kilovoltage images by triggered readout of unexposed frames
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poulsen, Per Rugaard, E-mail: per.poulsen@rm.dk; Jonassen, Johnny; Jensen, Carsten
2015-11-15
Purpose: The gantry-mounted kilovoltage (kV) imager of modern linear accelerators can be used for real-time tumor localization during radiation treatment delivery. However, the kV image quality often suffers from cross-scatter from the megavoltage (MV) treatment beam. This study investigates readout of unexposed kV frames as a means to improve the kV image quality in a series of experiments and a theoretical model of the observed image quality improvements. Methods: A series of fluoroscopic images were acquired of a solid water phantom with an embedded gold marker and an air cavity with and without simultaneous radiation of the phantom with amore » 6 MV beam delivered perpendicular to the kV beam with 300 and 600 monitor units per minute (MU/min). An in-house built device triggered readout of zero, one, or multiple unexposed frames between the kV exposures. The unexposed frames contained part of the MV scatter, consequently reducing the amount of MV scatter accumulated in the exposed frames. The image quality with and without unexposed frame readout was quantified as the contrast-to-noise ratio (CNR) of the gold marker and air cavity for a range of imaging frequencies from 1 to 15 Hz. To gain more insight into the observed CNR changes, the image lag of the kV imager was measured and used as input in a simple model that describes the CNR with unexposed frame readout in terms of the contrast, kV noise, and MV noise measured without readout of unexposed frames. Results: Without readout of unexposed kV frames, the quality of intratreatment kV images decreased dramatically with reduced kV frequencies due to MV scatter. The gold marker was only visible for imaging frequencies ≥3 Hz at 300 MU/min and ≥5 Hz for 600 MU/min. Visibility of the air cavity required even higher imaging frequencies. Readout of multiple unexposed frames ensured visibility of both structures at all imaging frequencies and a CNR that was independent of the kV frame rate. The image lag was 12.2%, 2.2%, and 0.9% in the first, second, and third frame after an exposure. The CNR model predicted the CNR with triggered image readout with a mean absolute error of 2.0% for the gold marker. Conclusions: A device that triggers readout of unexposed frames during kV fluoroscopy was built and shown to greatly improve the quality of intratreatment kV images. A simple theoretical model successfully described the CNR improvements with the device.« less
Weighing In: The Taste-Engineering Frame in Obesity Expert Discourse
Zimmerman, Frederick J.; Gilliam, Franklin D.
2015-01-01
Objectives. We sought expert opinion on the problems with 2 dominant obesity-prevention discourse frames—personal responsibility and the environment—and examined alternative frames for understanding and addressing obesity. Methods. We conducted 60-minute, semistructured interviews with 15 US-based obesity experts. We manually coded and entered interview transcripts into software, generating themes and subthematic areas that captured the debate’s essence. Results. Although the environmental frame is the dominant model used in communications with the public and policymakers, several experts found that communicating key messages within this frame was difficult because of the enormity of the obesity problem. A subframe of the environmental frame—the taste-engineering frame—identifies food industry strategies to influence the overconsumption of certain foods and beverages. This emerging frame deconstructs the environmental frame so that causal attributes and responsible agents are more easily identifiable and proposed policies and public health interventions more salient. Conclusions. Expert interviews are an invaluable resource for understanding how experts use frames in discussing their work and in conversations with the public and policymakers. Future empirical studies testing the effectiveness of the taste-engineering frame on public opinion and support for structural-level health policies are needed. PMID:25602888
News Media Framing of New York City’s Sugar-Sweetened Beverage Portion-Size Cap
Cohen, Joanna E.; Truant, Patricia L.; Rutkow, Lainie; Kanarek, Norma F.; Barry, Colleen L.
2015-01-01
Objectives. We assessed news media framing of New York City’s proposed regulation to prohibit the sale of sugar-sweetened beverages greater than 16 ounces. Methods. We conducted a quantitative content analysis of print and television news from within and outside New York City media markets. We examined support for and opposition to the portion-size cap in the news coverage from its May 31, 2012, proposal through the appellate court ruling on July 31, 2013. Results. News coverage corresponded to key events in the policy’s evolution. Although most stories mentioned obesity as a problem, a larger proportion used opposing frames (84%) than pro-policy frames (36%). Mention of pro-policy frames shifted toward the policy’s effect on special populations. The debate’s most prominent frame was the opposing frame that the policy was beyond the government’s role (69%). Conclusions. News coverage within and outside the New York City media market was more likely to mention arguments in opposition to than in support of the portion-size cap. Understanding how the news media framed this issue provides important insights for advocates interested in advancing similar measures in other jurisdictions. PMID:26378853
Spacecraft Reed-Solomon downlink module
NASA Technical Reports Server (NTRS)
Luong, Huy H. (Inventor); Donaldson, James A. (Inventor); Wood, Steven H. (Inventor)
1998-01-01
Apparatus and method for providing downlink frames to be transmitted from a spacecraft to a ground station. Each downlink frame includes a synchronization pattern and a transfer frame. The apparatus may comprise a monolithic Reed-Solomon downlink (RSDL) encoding chip coupled to data buffers for storing transfer frames. The RSKL chip includes a timing device, a bus interface, a timing and control unit, a synchronization pattern unit, and a Reed-Solomon encoding unit, and a bus arbiter.
40 CFR 35.110 - Time frame for EPA action.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Time frame for EPA action. 35.110 Section 35.110 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL... frame for EPA action. The Regional Administrator will review a complete application and either approve...
12 CFR 1805.503 - Time frame for raising match.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Time frame for raising match. 1805.503 Section 1805.503 Banks and Banking COMMUNITY DEVELOPMENT FINANCIAL INSTITUTIONS FUND, DEPARTMENT OF THE... frame for raising match. Applicants shall satisfy matching funds requirements within the period set...
Effective or ineffective: Attribute framing and the human papillomavirus (HPV) vaccine
Bigman, Cabral A.; Cappella, Joseph N.; Hornik, Robert C.
2010-01-01
Objectives To experimentally test whether presenting logically equivalent, but differently valenced effectiveness information (i.e. attribute framing) affects perceived effectiveness of the human papillomavirus (HPV) vaccine, vaccine related intentions and policy opinions. Method A survey-based experiment (N= 334) was fielded in August and September 2007 as part of a larger ongoing web-enabled monthly survey, the Annenberg National Health Communication Survey. Participants were randomly assigned to read a short passage about the HPV vaccine that framed vaccine effectiveness information in one of five ways. Afterward, they rated the vaccine and related opinion questions. Main statistical methods included ANOVA and t-tests. Results On average, respondents exposed to positive framing (70% effective) rated the HPV vaccine as more effective and were more supportive of vaccine mandate policy than those exposed to the negative frame (30% ineffective) or the control frame. Mixed valence frames showed some evidence for order effects; phrasing that ended by emphasizing vaccine ineffectiveness showed similar vaccine ratings to the negative frame. Conclusions The experiment finds that logically equivalent information about vaccine effectiveness not only influences perceived effectiveness, but can in some cases influence support for policies mandating vaccine use. Practice implications These framing effects should be considered when designing messages. PMID:20851560
Time Pressure Increases Cooperation in Competitively Framed Social Dilemmas
Cone, Jeremy; Rand, David G.
2014-01-01
What makes people willing to pay costs to benefit others? Does such cooperation require effortful self-control, or do automatic, intuitive processes favor cooperation? Time pressure has been shown to increase cooperative behavior in Public Goods Games, implying a predisposition towards cooperation. Consistent with the hypothesis that this predisposition results from the fact that cooperation is typically advantageous outside the lab, it has further been shown that the time pressure effect is undermined by prior experience playing lab games (where selfishness is the more advantageous strategy). Furthermore, a recent study found that time pressure increases cooperation even in a game framed as a competition, suggesting that the time pressure effect is not the result of social norm compliance. Here, we successfully replicate these findings, again observing a positive effect of time pressure on cooperation in a competitively framed game, but not when using the standard cooperative framing. These results suggest that participants' intuitions favor cooperation rather than norm compliance, and also that simply changing the framing of the Public Goods Game is enough to make it appear novel to participants and thus to restore the time pressure effect. PMID:25551386
Time pressure increases cooperation in competitively framed social dilemmas.
Cone, Jeremy; Rand, David G
2014-01-01
What makes people willing to pay costs to benefit others? Does such cooperation require effortful self-control, or do automatic, intuitive processes favor cooperation? Time pressure has been shown to increase cooperative behavior in Public Goods Games, implying a predisposition towards cooperation. Consistent with the hypothesis that this predisposition results from the fact that cooperation is typically advantageous outside the lab, it has further been shown that the time pressure effect is undermined by prior experience playing lab games (where selfishness is the more advantageous strategy). Furthermore, a recent study found that time pressure increases cooperation even in a game framed as a competition, suggesting that the time pressure effect is not the result of social norm compliance. Here, we successfully replicate these findings, again observing a positive effect of time pressure on cooperation in a competitively framed game, but not when using the standard cooperative framing. These results suggest that participants' intuitions favor cooperation rather than norm compliance, and also that simply changing the framing of the Public Goods Game is enough to make it appear novel to participants and thus to restore the time pressure effect.
Stefanik-Sidener, Kelsey
2013-01-01
Diabetes is a growing yet misunderstood health concern in the United States. This study examined the ways in which diabetes has been framed by the New York Times over the past decade. The public's perception of the causes and solutions to complex problems such as diabetes has significant implications for the way public policy interventions are viewed; therefore, understanding how diabetes is being framed in the media can be an important first step in shifting public opinion about ways to combat the disease. A content analysis of 239 articles published in the New York Times between 2000 and 2010 revealed that nearly one-third of articles failed to differentiate between type 1, type 2, and gestational diabetes, which may cause confusion given substantial differences in the root cause and treatment of each. An examination of frames used within each type of diabetes showed that the overall dominant frame across types was either a medical frame or a behavioral frame, with deficient use of a societal frame. The limited use of societal-level framing may make it difficult for the public to see the wider consequences of diabetes and decreases the likelihood of public support for policy solutions to combat the disease.
Reference Frames in Relativistic Space-Time
NASA Astrophysics Data System (ADS)
Soffel, M.; Herold, H.; Ruder, H.; Schneider, M.
Three fundamental concepts of reference frames in relativistic space-time are confronted: 1. the gravitation compass, 2. the stellar compass and 3. the inertial compass. It is argued that under certain conditions asymptotically fixed (stellar) reference frames can be introduced with the same rigour as local Fermi frames, thereby eliminating one possible psychological reason why the importance of Fermi frames frequently has been overestimated in the past. As applications of these three concepts the authors discuss: 1. a relativistic definition of the geoid, 2. a relativistic astrometric problem and 3. the post-Newtonian theory of a laser gyroscope fixed to the Earth's surface.
Dynamic Imaging of the Eye, Optic Nerve, and Extraocular Muscles With Golden Angle Radial MRI
Smith, David S.; Smith, Alex K.; Welch, E. Brian; Smith, Seth A.
2017-01-01
Purpose The eye and its accessory structures, the optic nerve and the extraocular muscles, form a complex dynamic system. In vivo magnetic resonance imaging (MRI) of this system in motion can have substantial benefits in understanding oculomotor functioning in health and disease, but has been restricted to date to imaging of static gazes only. The purpose of this work was to develop a technique to image the eye and its accessory visual structures in motion. Methods Dynamic imaging of the eye was developed on a 3-Tesla MRI scanner, based on a golden angle radial sequence that allows freely selectable frame-rate and temporal-span image reconstructions from the same acquired data set. Retrospective image reconstructions at a chosen frame rate of 57 ms per image yielded high-quality in vivo movies of various eye motion tasks performed in the scanner. Motion analysis was performed for a left–right version task where motion paths, lengths, and strains/globe angle of the medial and lateral extraocular muscles and the optic nerves were estimated. Results Offline image reconstructions resulted in dynamic images of bilateral visual structures of healthy adults in only ∼15-s imaging time. Qualitative and quantitative analyses of the motion enabled estimation of trajectories, lengths, and strains on the optic nerves and extraocular muscles at very high frame rates of ∼18 frames/s. Conclusions This work presents an MRI technique that enables high-frame-rate dynamic imaging of the eyes and orbital structures. The presented sequence has the potential to be used in furthering the understanding of oculomotor mechanics in vivo, both in health and disease. PMID:28813574
Omorczyk, Jarosław; Nosiadek, Leszek; Ambroży, Tadeusz; Nosiadek, Andrzej
2015-01-01
The main aim of this study was to verify the usefulness of selected simple methods of recording and fast biomechanical analysis performed by judges of artistic gymnastics in assessing a gymnast's movement technique. The study participants comprised six artistic gymnastics judges, who assessed back handsprings using two methods: a real-time observation method and a frame-by-frame video analysis method. They also determined flexion angles of knee and hip joints using the computer program. In the case of the real-time observation method, the judges gave a total of 5.8 error points with an arithmetic mean of 0.16 points for the flexion of the knee joints. In the high-speed video analysis method, the total amounted to 8.6 error points and the mean value amounted to 0.24 error points. For the excessive flexion of hip joints, the sum of the error values was 2.2 error points and the arithmetic mean was 0.06 error points during real-time observation. The sum obtained using frame-by-frame analysis method equaled 10.8 and the mean equaled 0.30 error points. Error values obtained through the frame-by-frame video analysis of movement technique were higher than those obtained through the real-time observation method. The judges were able to indicate the number of the frame in which the maximal joint flexion occurred with good accuracy. Using the real-time observation method as well as the high-speed video analysis performed without determining the exact angle for assessing movement technique were found to be insufficient tools for improving the quality of judging.
Sex and age-level differences of walking time in preschool children on an obstacle frame
2012-01-01
Background Stepping over an obstacle is a kind of compound movement that makes walking more difficult, especially for preschool children. This study examines sex and age-level differences in walking time in preschool children on an obstacle frame. Methods The participants included 324 healthy preschool children: four-year-old boys (51) and girls (51), five-year-old boys (50) and girls (60), and six-year-old boys (62) and girls (50). A 5 cm- or 10 cm-high obstacle (depth 11.5 cm, width 23.5 cm) was set at the halfway point of a 200 cm × 10 cm walking course. Results The participants walked to the end of the course and back as fast as possible under three conditions: no obstacle, low obstacle and high obstacle. Walking time showed age-level differences in all conditions, but there were no differences in sex. Age levels were divided into two groups, with one group within the first six months of their birthday, and the second group within the last six months of that year. Walking time for children in the first half of their fourth year was longer than that of the five- and six-year-old children. In addition, for children in the last half of their fourth year, walking time was longer than both sexes in the last half of their fifth and sixth years. The children in the latter half of their fifth year had a longer walking time in the high obstacle condition than those in the last half of their sixth year. In the four-year-old participants, walking time was shorter with no obstacles than with a high obstacle frame. Conclusions In the above data, obstacle course walking time does not show a gender difference, except that the four-year-old participants needed longer than the five- and six-year-old children. Setting the obstacle 10 cm high also produced a different walking time in the five- and six-year-old participants. The high obstacle step test (10 cm) best evaluated the dynamic balance of preschool children. PMID:22738328
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josh Sugar, Dave Robinson
2014-01-24
Performs a cross-correlation calculation to align images. This is particularly useful for aligning frames of a movie so that an object of interest does not spatially drift. For in situ microscopy experiments. Movies are collected where an object changes with time. At the same time, the object usually drifts too. This shifts the movie frames so that the object is aligned from frame to frame. Then it is easy to see the object changes without the added complication of it moving too.
Echocardiogram video summarization
NASA Astrophysics Data System (ADS)
Ebadollahi, Shahram; Chang, Shih-Fu; Wu, Henry D.; Takoma, Shin
2001-05-01
This work aims at developing innovative algorithms and tools for summarizing echocardiogram videos. Specifically, we summarize the digital echocardiogram videos by temporally segmenting them into the constituent views and representing each view by the most informative frame. For the segmentation we take advantage of the well-defined spatio- temporal structure of the echocardiogram videos. Two different criteria are used: presence/absence of color and the shape of the region of interest (ROI) in each frame of the video. The change in the ROI is due to different modes of echocardiograms present in one study. The representative frame is defined to be the frame corresponding to the end- diastole of the heart cycle. To locate the end-diastole we track the ECG of each frame to find the exact time the time- marker on the ECG crosses the peak of the end-diastole we track the ECG of each frame to find the exact time the time- marker on the ECG crosses the peak of the R-wave. The corresponding frame is chosen to be the key-frame. The entire echocardiogram video can be summarized into either a static summary, which is a storyboard type of summary and a dynamic summary, which is a concatenation of the selected segments of the echocardiogram video. To the best of our knowledge, this if the first automated system for summarizing the echocardiogram videos base don visual content.
Guede-Fernandez, F; Ferrer-Mileo, V; Ramos-Castro, J; Fernandez-Chimeno, M; Garcia-Gonzalez, M A
2015-01-01
The aim of this paper is to present a smartphone based system for real-time pulse-to-pulse (PP) interval time series acquisition by frame-to-frame camera image processing. The developed smartphone application acquires image frames from built-in rear-camera at the maximum available rate (30 Hz) and the smartphone GPU has been used by Renderscript API for high performance frame-by-frame image acquisition and computing in order to obtain PPG signal and PP interval time series. The relative error of mean heart rate is negligible. In addition, measurement posture and the employed smartphone model influences on the beat-to-beat error measurement of heart rate and HRV indices have been analyzed. Then, the standard deviation of the beat-to-beat error (SDE) was 7.81 ± 3.81 ms in the worst case. Furthermore, in supine measurement posture, significant device influence on the SDE has been found and the SDE is lower with Samsung S5 than Motorola X. This study can be applied to analyze the reliability of different smartphone models for HRV assessment from real-time Android camera frames processing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boerner, M.; Frank, A.; Pelka, A.
2012-04-15
This article reports on the development and set-up of a Nomarski-type multi-frame interferometer as a time and space resolving diagnostics of the free electron density in laser-generated plasma. The interferometer allows the recording of a series of 4 images within 6 ns of a single laser-plasma interaction. For the setup presented here, the minimal accessible free electron density is 5 x 10{sup 18} cm{sup -3}, the maximal one is 2 x 10{sup 20} cm{sup -3}. Furthermore, it provides a resolution of the electron density in space of 50 {mu}m and in time of 0.5 ns for one image with amore » customizable magnification in space for each of the 4 images. The electron density was evaluated from the interferograms using an Abel inversion algorithm. The functionality of the system was proven during first experiments and the experimental results are presented and discussed. A ray tracing procedure was realized to verify the interferometry pictures taken. In particular, the experimental results are compared to simulations and show excellent agreement, providing a conclusive picture of the evolution of the electron density distribution.« less
A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment.
Fuangrod, Todsaporn; Woodruff, Henry C; van Uytven, Eric; McCurdy, Boyd M C; Kuncic, Zdenka; O'Connor, Daryl J; Greer, Peter B
2013-09-01
To design and develop a real-time electronic portal imaging device (EPID)-based delivery verification system for dynamic intensity modulated radiation therapy (IMRT) which enables detection of gross treatment delivery errors before delivery of substantial radiation to the patient. The system utilizes a comprehensive physics-based model to generate a series of predicted transit EPID image frames as a reference dataset and compares these to measured EPID frames acquired during treatment. The two datasets are using MLC aperture comparison and cumulative signal checking techniques. The system operation in real-time was simulated offline using previously acquired images for 19 IMRT patient deliveries with both frame-by-frame comparison and cumulative frame comparison. Simulated error case studies were used to demonstrate the system sensitivity and performance. The accuracy of the synchronization method was shown to agree within two control points which corresponds to approximately ∼1% of the total MU to be delivered for dynamic IMRT. The system achieved mean real-time gamma results for frame-by-frame analysis of 86.6% and 89.0% for 3%, 3 mm and 4%, 4 mm criteria, respectively, and 97.9% and 98.6% for cumulative gamma analysis. The system can detect a 10% MU error using 3%, 3 mm criteria within approximately 10 s. The EPID-based real-time delivery verification system successfully detected simulated gross errors introduced into patient plan deliveries in near real-time (within 0.1 s). A real-time radiation delivery verification system for dynamic IMRT has been demonstrated that is designed to prevent major mistreatments in modern radiation therapy.
Oh, Hyun Young; Kim, Daeho
2012-01-01
Objective Research suggests that the contents of delusions in schizophrenia are influenced by culture and social environment. However, few studies have investigated the chronological change of such delusions within a society. To investigate specifically the changes in the persecutory delusions of schizophrenia that have occurred over time, we compared the nature of the persecutors and their persecutory behaviors among inpatients with schizophrenia. Methods All admissions to the psychiatric unit of Hanyang University Guri Hospital with discharge diagnoses of schizophrenia during two different five-year time frames (1996-2000 and 2006-2010) were reviewed. From their inpatient medical records, we investigated the descriptions of persecutors and their persecutory behaviors in the delusions of 124 patients (54 in the1990s and 72 in the 2000s). Results Overall, persecutory behaviors and nature of persecutors in the delusions of schizophrenia did not differ between the two time frames. However, subgroup analysis revealed that in women but not in men, rejection as a persecutory behavior was significantly higher in the 1990s (p<0.05). Conclusion The ten-year time interval may be too short to find significant changes in delusional content in general. However, our additional finding in women may be a result of the tremendous change in status of Korean women during the last decade. PMID:23251194
Sailer, Uta; Rosenberg, Patricia; Nima, Ali Al; Gamble, Amelie; Gärling, Tommy; Archer, Trevor; Garcia, Danilo
2014-01-01
Background. Previous studies have established a link between how people relate to their past, present, and future (i.e., time perspective) and subjective well-being (i.e., life satisfaction, positive and negative affect). Time perspective comprises five dimensions: Past Positive, Past Negative, Present Hedonistic, Present Fatalistic, and Future. Life satisfaction can also be evaluated in relation to different time frames. Moreover, approach related positive affect is associated to a different concept of well-being labeled psychological well-being. In the present study we extend previous findings by investigating the effect of time perspective on the time frame of evaluations of life satisfaction (past, present, future) and by investigating the relationship between time perspective and psychological well-being. Method. Questionnaires on time perspective (Zimbardo's Time Perspective Inventory), temporal life satisfaction (Temporal Satisfaction with Life Scale), affect (Positive Affect and Negative Affect Schedule), and psychological well-being (Scales of Psychological Well-Being-short version) were answered by 453 individuals. Two different structural equation models were tested, one of the relationship between time perspective and temporal life satisfaction, and the other of the relationship between time perspective, affect and psychological well-being. Results. Time perspective affected life satisfaction depending on the time scale on which it was evaluated-memory of a negative past influenced life satisfaction in all time frames, and a positive view of the past influenced both past and future life satisfaction. Moreover, less rumination about past negative events (i.e., low score on Past Negative), the tendency to take risks in the present to achieve happy feelings and/or avoid boredom (i.e., high scores on Present Hedonistic), and a less hopeless and pessimistic view about the present (low scores on Present Fatalistic) were associated with higher levels of psychological well-being and positive affect. These same time perspective dimensions were associated with lower levels of negative affect. The Future time perspective dimension (i.e., approaching life with self-control, punctuality, and planning for the future) was associated with both psychological well-being and positive affect. Conclusions. High levels of both subjective and psychological well-being are related to a happier and a less sinister past, a more hedonistic and less fatalistic present, as well as to a more structured future.
Sailer, Uta; Rosenberg, Patricia; Nima, Ali Al; Gamble, Amelie; Gärling, Tommy; Archer, Trevor
2014-01-01
Background. Previous studies have established a link between how people relate to their past, present, and future (i.e., time perspective) and subjective well-being (i.e., life satisfaction, positive and negative affect). Time perspective comprises five dimensions: Past Positive, Past Negative, Present Hedonistic, Present Fatalistic, and Future. Life satisfaction can also be evaluated in relation to different time frames. Moreover, approach related positive affect is associated to a different concept of well-being labeled psychological well-being. In the present study we extend previous findings by investigating the effect of time perspective on the time frame of evaluations of life satisfaction (past, present, future) and by investigating the relationship between time perspective and psychological well-being. Method. Questionnaires on time perspective (Zimbardo’s Time Perspective Inventory), temporal life satisfaction (Temporal Satisfaction with Life Scale), affect (Positive Affect and Negative Affect Schedule), and psychological well-being (Scales of Psychological Well-Being—short version) were answered by 453 individuals. Two different structural equation models were tested, one of the relationship between time perspective and temporal life satisfaction, and the other of the relationship between time perspective, affect and psychological well-being. Results. Time perspective affected life satisfaction depending on the time scale on which it was evaluated—memory of a negative past influenced life satisfaction in all time frames, and a positive view of the past influenced both past and future life satisfaction. Moreover, less rumination about past negative events (i.e., low score on Past Negative), the tendency to take risks in the present to achieve happy feelings and/or avoid boredom (i.e., high scores on Present Hedonistic), and a less hopeless and pessimistic view about the present (low scores on Present Fatalistic) were associated with higher levels of psychological well-being and positive affect. These same time perspective dimensions were associated with lower levels of negative affect. The Future time perspective dimension (i.e., approaching life with self-control, punctuality, and planning for the future) was associated with both psychological well-being and positive affect. Conclusions. High levels of both subjective and psychological well-being are related to a happier and a less sinister past, a more hedonistic and less fatalistic present, as well as to a more structured future. PMID:24688878
Real-time CT-video registration for continuous endoscopic guidance
NASA Astrophysics Data System (ADS)
Merritt, Scott A.; Rai, Lav; Higgins, William E.
2006-03-01
Previous research has shown that CT-image-based guidance could be useful for the bronchoscopic assessment of lung cancer. This research drew upon the registration of bronchoscopic video images to CT-based endoluminal renderings of the airway tree. The proposed methods either were restricted to discrete single-frame registration, which took several seconds to complete, or required non-real-time buffering and processing of video sequences. We have devised a fast 2D/3D image registration method that performs single-frame CT-Video registration in under 1/15th of a second. This allows the method to be used for real-time registration at full video frame rates without significantly altering the physician's behavior. The method achieves its speed through a gradient-based optimization method that allows most of the computation to be performed off-line. During live registration, the optimization iteratively steps toward the locally optimal viewpoint at which a CT-based endoluminal view is most similar to a current bronchoscopic video frame. After an initial registration to begin the process (generally done in the trachea for bronchoscopy), subsequent registrations are performed in real-time on each incoming video frame. As each new bronchoscopic video frame becomes available, the current optimization is initialized using the previous frame's optimization result, allowing continuous guidance to proceed without manual re-initialization. Tests were performed using both synthetic and pre-recorded bronchoscopic video. The results show that the method is robust to initialization errors, that registration accuracy is high, and that continuous registration can proceed on real-time video at >15 frames per sec. with minimal user-intervention.
Modeling laser-plasma acceleration in the laboratory frame
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2011-01-01
A simulation of laser-plasma acceleration in the laboratory frame. Both the laser and the wakefield buckets must be resolved over the entire domain of the plasma, requiring many cells and many time steps. While researchers often use a simulation window that moves with the pulse, this reduces only the multitude of cells, not the multitude of time steps. For an artistic impression of how to solve the simulation by using the boosted-frame method, watch the video "Modeling laser-plasma acceleration in the wakefield frame".
Gerend, Mary A.; Maner, Jon K.
2010-01-01
Objective Message framing is a theoretically grounded health communication strategy designed to motivate action by emphasizing the benefits of engaging in a particular behavior (gains) or the costs of failing to engage in the behavior (losses). This study investigated whether the effectiveness of a framed message depends on the emotional state of the message recipient. We examined effects of fear versus anger, emotions that frequently occur within the context of health decision-making. Methods Undergraduate students (N = 133) were randomly assigned to complete a fear or anger induction task after which they read a gain- or loss-framed pamphlet promoting fruit and vegetable consumption. Fruit and vegetable intake (servings per day) was subsequently assessed over the following two weeks. Results As predicted, a significant frame by emotion interaction was observed, such that participants in the fear condition reported eating more servings of fruits and vegetables after exposure to a loss-framed message than to a gain-framed message. In contrast, participants in the anger condition reported eating (marginally) more servings of fruits and vegetables after exposure to a gain-framed message than to a loss-framed message. That is, greater increases in fruit and vegetable intake from baseline to follow-up were observed when frame was matched to participants’ emotional state than when it was mismatched. Conclusion The effectiveness of framed health communications depends on the message recipient’s current emotional state. Affective factors that are incidental to the behavior recommended in a health communication can affect the relative success of gain- and loss-framed appeals. PMID:21534679
Ergonomic study and static analysis for new design of electric scooter
NASA Astrophysics Data System (ADS)
Fadzly, M. K.; Munirah, Anis; Shayfull, Z.; Saad, Mohd Sazli
2017-09-01
The purposes of this project are to design and diversify the function of a battery powered scooter frame which is more practical for the human factor in ergonomic and optimum design. The new design is based on ideas which are studied from existing scooter frame, United States Patent design and European States International Patent design. The final idea of concept design for scooter frame is based on concept chosen from the best characteristics and it is divided into three main difference ideas and the matrix evaluation method is applied. Analysis that applies to frame design, arm, rim and drive train component is based on Cosmos Express program. As a conclusion, the design that is produce are able to carry the maximum also has more practical features in ergonomic view.
42 CFR 62.73 - What are the procedures for participation in the Special Repayment Program?
Code of Federal Regulations, 2010 CFR
2010-10-01
... with the site to obtain employment at the site. (f) Effect of failure to meet established time frames... medical specialty for which the National Health service Corps has no need. (d) Time frames for matching... frames described in paragraph (d) of this section, the Secretary will determine that such individual is...
A frame-critical policy analysis of Canada's response to the World Food Summit 1998-2008.
Mah, Catherine L; Hamill, Catherine; Rondeau, Krista; McIntyre, Lynn
2014-01-01
The 2012 visit to Canada of Olivier De Schutter, the United Nations Special Rapporteur on the Right to Food, led to a public rebuff by Canadian governmental officials. This paper adapts the frame-critical policy analysis of Schön and Rein (1994), to explore the rhetorical basis for this conflict. This examination is offered as an illustrative example of how food insecurity is framed as a public policy problem in a high-income nation and how this framing has changed over time. We analyze Canada's decade of sequential responses to the 1996 World Food Summit, spanning 1998-2008, in the form of Canada's Action Plan on Food Security, and its subsequent Progress Reports. We conducted a qualitative policy analysis, adapting the frame-critical approach first delineated by Schön and Rein (1994). This analysis uses a social constructionist approach to map out the relationships between tacit understanding of policy by particular actors, explicit rhetoric in the public domain, and action in this policy area over time. We identify three key ways in which competing rhetorical frames arise over time: frame shifts (e.g., a shift away from language highlighting the right to food and health); frame blending (e.g., discussion about poverty becomes obscured by complexity discourse); and within-frame incongruence (e.g., monitoring for health indicators that are unrelated to policy solutions). Together, these frames illustrate how the conflict embodied in the UN Special Rapporteur's visit has been deeply woven into the policy discourse on food insecurity in Canada over time. Frame-critical analysis is instructive for exposing and also predicting tensions that impede forward progress on difficult policy issues. Accordingly, such analyses may be helpful in not only dissecting how policy can become 'stuck' in the process of change but in active reframing towards new policy solutions.
Motion-Blur-Free High-Speed Video Shooting Using a Resonant Mirror
Inoue, Michiaki; Gu, Qingyi; Takaki, Takeshi; Ishii, Idaku; Tajima, Kenji
2017-01-01
This study proposes a novel concept of actuator-driven frame-by-frame intermittent tracking for motion-blur-free video shooting of fast-moving objects. The camera frame and shutter timings are controlled for motion blur reduction in synchronization with a free-vibration-type actuator vibrating with a large amplitude at hundreds of hertz so that motion blur can be significantly reduced in free-viewpoint high-frame-rate video shooting for fast-moving objects by deriving the maximum performance of the actuator. We develop a prototype of a motion-blur-free video shooting system by implementing our frame-by-frame intermittent tracking algorithm on a high-speed video camera system with a resonant mirror vibrating at 750 Hz. It can capture 1024 × 1024 images of fast-moving objects at 750 fps with an exposure time of 0.33 ms without motion blur. Several experimental results for fast-moving objects verify that our proposed method can reduce image degradation from motion blur without decreasing the camera exposure time. PMID:29109385
Analysis of Spark-Ignition Engine Knock as Seen in Photographs Taken at 200,000 Frames Per Second
NASA Technical Reports Server (NTRS)
Miller, Cearcy D.; Olsen, H. Lowell; Logan, Walter O., Jr.; Osterstrom, Gordon E
1946-01-01
A motion picture of the development of knock in a spark-ignition engine, is presented, which consists of 20 photographs taken at intervals of 5 microseconds, or at a rate of 200,000 photographs a second, with an equivalent wide-open exposure time of 6.4 microseconds for each photograph. A motion picture of a complete combustion process, including the development of knock, taken at the rate of 40,000 photographs a second is also presented to assist the reader in orienting the photographs of the knock development taken at 200,000 frames per second. The photographs taken at 200,000 frames per second are analyzed and the conclusion is made that the type of knock in the spark-ignition engine involving violent gas vibration originates as self-propagating disturbance starting at a point in the.burn1ig or autoigniting gases and spreading out from that point through the incompletely burned gases at a rate as high as 6800 feet per second, or about twice the speed of sound in the burned gases. Apparent formation of free carbon particles in both the burning and the burned gas is observed within 10 microseconds after passage of the knock disturbance through the gases.
Mays, Darren; Zhao, Xiaoquan
2016-01-01
Objective To investigate the effects of gain- and loss-framed indoor tanning (IT) prevention messages among young adult women, and examine the potential moderating effect of self-affirmation. Methods Young adult women ages 18 to 30 who reported IT at least once in the past year (n = 475) participated in an online experiment. Participants first completed assessments of IT behavior and related constructs and were randomized to either a self-affirmation manipulation or control condition. Then, participants were randomized to either a gain-framed message emphasizing the benefits of avoiding IT or a loss-framed message emphasizing the risks of IT. Participants completed outcome measures of intentions to IT, intentions to quit IT, and emotional and cognitive responses to the framed messages. Results Compared with gain-framed messages, loss-framed messages led to weaker intentions to IT and stronger intentions to quit IT. Self-affirmation did not moderate message framing effects, but had a main effect increasing intentions to IT. Mediation analyses indicate that loss-framed messages affect IT behavioral intentions by increasing fear and self-affirmation may have increased intentions to IT by producing defensive reactions to the framed messages. Conclusions Loss-framed messages were more effective for reducing intentions to IT and promoting intentions to quit IT among young women after a brief exposure, and emotional response appears to be one pathway through which loss-framed messages affect behavioral outcomes. Messages emphasizing the risks of IT may be optimal as a public health intervention strategy. Unlike other behavioral domains, self-affirmation did not reduce defensive processing of loss-framed messages. PMID:26192383
Tercyak, Kenneth P.
2015-01-01
Objectives. We investigated the impact of indoor tanning device warnings that communicate the risks associated with indoor tanning (i.e., loss framed) or the benefits of avoiding indoor tanning (i.e., gain framed). Methods. A convenience sample of non-Hispanic White women aged 18 to 30 years who tanned indoors at least once in the past year (n = 682) participated in a within-subjects experiment. Participants completed baseline measures and reported indoor tanning intentions and intentions to quit indoor tanning in response to 5 warning messages in random order. A text-only control warning was based on Food and Drug Administration–required warnings for indoor tanning devices. Experimental warnings included graphic content and were either gain or loss framed. Results. In multivariable analyses, gain-framed warnings did not differ from the control warning on women’s intentions to tan indoors, but they prompted stronger intentions to quit than the control message. Loss-framed warnings significantly reduced intentions to tan indoors and increased intentions to quit indoor tanning compared with control and gain-framed warnings. Conclusions. The public health impact of indoor tanning device warnings can be enhanced by incorporating graphic content and leveraging gain- and loss-framed messaging. PMID:26066932
CASA-Mot technology: how results are affected by the frame rate and counting chamber.
Bompart, Daznia; García-Molina, Almudena; Valverde, Anthony; Caldeira, Carina; Yániz, Jesús; Núñez de Murga, Manuel; Soler, Carles
2018-04-04
For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20µm . The frame rate was previously limited by the hardware, although changes in the number of images collected could lead to significant variations in some kinematic parameters, mainly in curvilinear velocity (VCL). A frame rate of 60 frames s-1 is widely considered to be the minimum necessary for satisfactory results. However, the frame rate is species specific and must be defined in each experimental condition. In conclusion, we show that the optimal combination of frame rate and counting chamber type and depth should be defined for each species and experimental condition in order to obtain reliable results.
Time and outcome framing in intertemporal tradeoffs.
Scholten, Marc; Read, Daniel
2013-07-01
A robust anomaly in intertemporal choice is the delay-speedup asymmetry: Receipts are discounted more, and payments are discounted less, when delayed than when expedited over the same interval. We developed 2 versions of the tradeoff model (Scholten & Read, 2010) to address such situations, in which an outcome is expected at a given time but then its timing is changed. The outcome framing model generalizes the approach taken by the hyperbolic discounting model (Loewenstein & Prelec, 1992): Not obtaining a positive outcome when expected is a worse than expected state, to which people are over-responsive, or hypersensitive, and not incurring a negative outcome when expected is a better than expected state, to which people are under-responsive, or hyposensitive. The time framing model takes a new approach: Delaying a positive outcome or speeding up a negative one involves a loss of time to which people are hypersensitive, and speeding up a positive outcome or delaying a negative one involves a gain of time to which people are hyposensitive. We compare the models on their quantitative predictions of indifference data from matching and preference data from choice. The time framing model systematically outperforms the outcome framing model. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Multi-Frame Convolutional Neural Networks for Object Detection in Temporal Data
2017-03-01
maximum 200 words) Given the problem of detecting objects in video , existing neural-network solutions rely on a post-processing step to combine...information across frames and strengthen conclusions. This technique has been successful for videos with simple, dominant objects but it cannot detect objects...Computer Science iii THIS PAGE INTENTIONALLY LEFT BLANK iv ABSTRACT Given the problem of detecting objects in video , existing neural-network solutions rely
Kroon, Anne C; Vliegenthart, Rens; van Selm, Martine
2017-07-01
In the past decade, European governments have implemented activating policy reforms to maximize older workers' employment and employability, representing a paradigmatic change in approaches to work and retirement. This study isolates the factors that explain the relative success and failure of competitive frames that are either in favor of or against activating policies in European news coverage, by applying time-series analysis (ordinary least squares with panel-corrected standard errors) to monthly aggregated news coverage in the Netherlands, the United Kingdom, Denmark, and Spain over the timespan 2006-2013. The results show that pro-activating and counteractivating frames generally coincide in competitive framing environments. The pro-activating frame proliferated in times of high employment protection, whereas the counteractivating frame prevailed stronger in conservative compared with progressive newspapers, and gained momentum during the aftermath of the financial crisis and in times governments on the economic left were in power. The study advances knowledge of competitive issue framing by demonstrating how the economic, policy, and political context matters for the emergence and evolvement of competing frames. In addition, the findings contribute to the understanding of the factors that contribute to news representations that promote active aging in European news, which may foster support for policy reforms that sustain older workers' employability.
Ultra-fast high-resolution hybrid and monolithic CMOS imagers in multi-frame radiography
NASA Astrophysics Data System (ADS)
Kwiatkowski, Kris; Douence, Vincent; Bai, Yibin; Nedrow, Paul; Mariam, Fesseha; Merrill, Frank; Morris, Christopher L.; Saunders, Andy
2014-09-01
A new burst-mode, 10-frame, hybrid Si-sensor/CMOS-ROIC FPA chip has been recently fabricated at Teledyne Imaging Sensors. The intended primary use of the sensor is in the multi-frame 800 MeV proton radiography at LANL. The basic part of the hybrid is a large (48×49 mm2) stitched CMOS chip of 1100×1100 pixel count, with a minimum shutter speed of 50 ns. The performance parameters of this chip are compared to the first generation 3-frame 0.5-Mpixel custom hybrid imager. The 3-frame cameras have been in continuous use for many years, in a variety of static and dynamic experiments at LANSCE. The cameras can operate with a per-frame adjustable integration time of ~ 120ns-to- 1s, and inter-frame time of 250ns to 2s. Given the 80 ms total readout time, the original and the new imagers can be externally synchronized to 0.1-to-5 Hz, 50-ns wide proton beam pulses, and record up to ~1000-frame radiographic movies typ. of 3-to-30 minute duration. The performance of the global electronic shutter is discussed and compared to that of a high-resolution commercial front-illuminated monolithic CMOS imager.
Measurement of cardiac output from dynamic pulmonary circulation time CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yee, Seonghwan, E-mail: Seonghwan.Yee@Beaumont.edu; Scalzetti, Ernest M.
Purpose: To introduce a method of estimating cardiac output from the dynamic pulmonary circulation time CT that is primarily used to determine the optimal time window of CT pulmonary angiography (CTPA). Methods: Dynamic pulmonary circulation time CT series, acquired for eight patients, were retrospectively analyzed. The dynamic CT series was acquired, prior to the main CTPA, in cine mode (1 frame/s) for a single slice at the level of the main pulmonary artery covering the cross sections of ascending aorta (AA) and descending aorta (DA) during the infusion of iodinated contrast. The time series of contrast changes obtained for DA,more » which is the downstream of AA, was assumed to be related to the time series for AA by the convolution with a delay function. The delay time constant in the delay function, representing the average time interval between the cross sections of AA and DA, was determined by least square error fitting between the convoluted AA time series and the DA time series. The cardiac output was then calculated by dividing the volume of the aortic arch between the cross sections of AA and DA (estimated from the single slice CT image) by the average time interval, and multiplying the result by a correction factor. Results: The mean cardiac output value for the six patients was 5.11 (l/min) (with a standard deviation of 1.57 l/min), which is in good agreement with the literature value; the data for the other two patients were too noisy for processing. Conclusions: The dynamic single-slice pulmonary circulation time CT series also can be used to estimate cardiac output.« less
Using a sociotechnical framework to understand adaptations in health IT implementation
Novak, Laurie Lovett; Holden, Richard J; Anders, Shilo H; Hong, Jennifer Y; Karsh, Ben-Tzion
2013-01-01
Purpose When barcode medication administration (BCMA) is implemented nurses are required to integrate not only a new set of procedures or artifacts into everyday work, but also an orientation to medication safety itself that is sometimes at odds with their own. This paper describes how the nurses’ orientation (the Practice Frame) can collide with the orientation that is represented by the technology and its implementation (the System Frame), resulting in adaptations at the individual and organization levels. Methods The paper draws on two qualitative research studies that examined the implementation of BCMA in inpatient settings using observation and ethnographic fieldwork, content analysis of email communications, and interviews with healthcare professionals. Results Two frames of reference are described: the System Frame and the Practice Frame. We found collisions of these frames that prompted adaptations at the individual and organization levels. The System Frame was less integrated and flexible than the Practice Frame, less able to account for all of the dimensions of everyday patient care to which medication administration is tied. Conclusion Collisions in frames during implementation of new technology result in adaptations at the individual and organization level that can have a variety of effects. We found adaptations to be a means of evolving both the work routines and the technology. Understanding the frames of clinical workers when new technology is being designed and implemented can inform changes to technology or organizational structure and policy that can preclude unproductive or unsafe adaptations. PMID:23562140
Ansari, Mojtaba; Hashemi, Hoda; Soltanshahi, Mehdi; Qutbi, Mohsen; Azizmohammadi, Zahra; Tabeie, Faraj; Javadi, Hamid; Jafari, Esmail; Barekat, Maryam; Assadi, Majid
2018-06-07
Evaluating the effects of heart cavity volume, presence and absence of perfusion defect, gender and type of study (stress and rest) on the difference of systolic parameters of myocardial perfusion scan in 16 and 8 framing gated SPECT imaging. Cardiac gated SPECT in both 16 and 8 framing simultaneously and both stress and rest phases at one-day protocol was performed for 50 patients. Data have been reconstructed by filter back projection (FBP) method and left ventricular (LV) systolic parameters were calculated by using QGS software. The effect of some factors such as LV cavity volume, presence and absence of perfusion defect, gender and type of study on data difference between 8 and 16 frames were evaluated. The differences in ejection fraction (EF), end-diastolic volume (EDV) and end-systolic volume (ESV) in both stress and rest were statistically significant. Difference in both framing was more in stress for EF and ESV, and was more in rest for EDV. Study type had a significant effect on differences in systolic parameters while gender had a significant effect on differences in EF and ESV in rest between both framings. In conclusion, results of this study revealed that difference of both 16 and 8 frames data in systolic phase were statistically significant and it seems that because of better efficiency of 16 frames, it cannot be replaced by 8 frames. Further well-designed studies are required to verify these findings.
Hull, Shawnika J
2014-01-01
Objective Researchers argue that gain framed messages should be more effective for prevention behaviors while loss frames should be more effective for detection behaviors (Rothman & Salovey, 1997). Evidence for this taxonomy has been mixed. This study examines whether the effects of gain and loss framed messages on HIV testing intentions is moderated by perceived risk of a positive result. Methods This experiment was conducted on-line and utilizes a single factor (frame: gain/loss) between subjects design, with a separate HIV test promotion control and a no message control to examine whether perceived risk of a positive test result moderates the effects of framed messages on intentions to seek an HIV test in the next 3 months. The sample (N=1052; age M = 22, SD = 2.22), recruited through Survey Sampling International, included 51% Black women (49% White women). Results HIV test promotion messages were more effective than no message but there were no other main effects for condition. Results also demonstrate a significant interaction between message frame and perceived risk, which is mediated through elaborative processing of the message. The interaction demonstrated an advantage for the loss framed message among women with some perceived risk and an advantage for the gain framed message among women with low perceived risk. Conclusion Results imply that the prevention/detection function of the behavior may be an inadequate distinction in the consideration of the effectiveness of framed messages promoting HIV testing. Rather, this study demonstrates that risk perceptions are an important moderator of framing effects. PMID:21767018
A novel surgical technique for a rat subcutaneous implantation of a tissue engineered scaffold
Khorramirouz, Reza; Go, Jason L.; Noble, Christopher; Jana, Soumen; Maxson, Eva; Lerman, Amir; Young, Melissa D.
2018-01-01
Objectives Subcutaneous implantations in small animal models are currently required for preclinical studies of acellular tissue to evaluate biocompatibility, including host recellularization and immunogenic reactivity. Methods Three rat subcutaneous implantation methods were evaluated in six Sprague Dawley rats. An acellular xenograft made from porcine pericardium was used as the tissue-scaffold. Three implantation methods were performed; 1) Suture method is where a tissue-scaffold was implanted by suturing its border to the external oblique muscle, 2) Control method is where a tissue-scaffold was implanted without any suturing or support, 3) Frame method is where a tissue-scaffold was attached to a circular frame composed of polycaprolactone (PCL) biomaterial and placed subcutaneously. After 1 and 4 weeks, tissue-scaffolds were explanted and evaluated by hematoxylin and eosin (H&E), Masson’s trichrome, Picrosirius Red, transmission electron microscopy (TEM), immunohistochemistry, and mechanical testing. Results Macroscopically, tissue-scaffold degradation with the suture method and tissue-scaffold folding with the control method were observed after 4 weeks. In comparison, the frame method demonstrated intact tissue scaffolds after 4 weeks. H&E staining showed progressive cell repopulation over the course of the experiment in all groups with acute and chronic inflammation observed in suture and control methods throughout the duration of the study. Immunohistochemistry quantification of CD3, CD 31, CD 34, CD 163, and αSMA showed a statistically significant differences between the suture, control and frame methods (P < 0.05) at both time points. The average tensile strength was 4.03 ± 0.49, 7.45 ± 0.49 and 5.72 ± 1.34 (MPa) after 1 week and 0.55 ± 0.26, 0.12 ± 0.03 and 0.41 ± 0.32 (MPa) after 4 weeks in the suture, control, and frame methods; respectively. TEM analysis showed an increase in inflammatory cells in both suture and control methods following implantation. Conclusion Rat subcutaneous implantation with the frame method was performed with success and ease. The surgical approach used for the frame technique was found to be the best methodology for in vivo evaluation of tissue engineered acellular scaffolds, where the frame method did not compromise mechanical strength, but it reduced inflammation significantly. PMID:29519681
Providing Young Women with Credible Health Information about Bleeding Disorders
Rhynders, Patricia A.; Sayers, Cynthia A.; Presley, Rodney J.; Thierry, JoAnn M.
2015-01-01
Background Approximately 1% of U.S. women may have an undiagnosed bleeding disorder, which can diminish quality of life and lead to life-threatening complications during menstruation, childbirth, and surgery. Purpose To understand young women’s knowledge, attitudes, and perceptions about bleeding disorders and determine the preferred messaging strategy (e.g., gain- versus loss-framed messages) for presenting information. Methods In September 2010, a web-assisted personal interview of women aged 18–25 years was conducted. Preliminary analyses were conducted in 2011 with final analyses in 2013. In total, 1,243 women participated. Knowledge of blood disorders was tabulated for these respondents. Menstrual experiences of women at risk for a bleeding disorder were compared with those not at risk using chi-square analyses. Perceived influence of gain- versus loss-framed messages also was compared. Results Participants knew that a bleeding disorder is a condition in which bleeding takes a long time to stop (77%) or blood does not clot (66%). Of the women, 57% incorrectly thought that a bleeding disorder is characterized by thin blood; many were unsure if bleeding disorders involve blood types, not getting a period, or mother and fetus having a different blood type. Women at risk for a bleeding disorder were significantly more likely to report that menstruation interfered with daily activities (36% vs 9%); physical or sports activities (46% vs 21%); social activities (29% vs 7%); and school or work activities (20% vs 9%) than women not at risk. Gain-framed messages were significantly more likely to influence women’s decisions to seek medical care than parallel loss-framed messages. Findings suggest that the most influential messages focus on knowing effective treatment is available (86% gain-framed vs 77% loss-framed); preventing pregnancy complications (79% gain- vs 71% loss-framed); and maintaining typical daily activities during menstrual periods. Conclusions Lack of information about bleeding disorders is a serious public health concern. Health communications focused on gain-framed statements might encourage symptomatic young women to seek diagnosis and treatment. These findings and corresponding recommendations align with Healthy People 2020 and with CDC’s goal of working to promote the health, safety, and quality of life of women at every life stage. PMID:25245800
Farabet, Clément; Paz, Rafael; Pérez-Carrasco, Jose; Zamarreño-Ramos, Carlos; Linares-Barranco, Alejandro; LeCun, Yann; Culurciello, Eugenio; Serrano-Gotarredona, Teresa; Linares-Barranco, Bernabe
2012-01-01
Most scene segmentation and categorization architectures for the extraction of features in images and patches make exhaustive use of 2D convolution operations for template matching, template search, and denoising. Convolutional Neural Networks (ConvNets) are one example of such architectures that can implement general-purpose bio-inspired vision systems. In standard digital computers 2D convolutions are usually expensive in terms of resource consumption and impose severe limitations for efficient real-time applications. Nevertheless, neuro-cortex inspired solutions, like dedicated Frame-Based or Frame-Free Spiking ConvNet Convolution Processors, are advancing real-time visual processing. These two approaches share the neural inspiration, but each of them solves the problem in different ways. Frame-Based ConvNets process frame by frame video information in a very robust and fast way that requires to use and share the available hardware resources (such as: multipliers, adders). Hardware resources are fixed- and time-multiplexed by fetching data in and out. Thus memory bandwidth and size is important for good performance. On the other hand, spike-based convolution processors are a frame-free alternative that is able to perform convolution of a spike-based source of visual information with very low latency, which makes ideal for very high-speed applications. However, hardware resources need to be available all the time and cannot be time-multiplexed. Thus, hardware should be modular, reconfigurable, and expansible. Hardware implementations in both VLSI custom integrated circuits (digital and analog) and FPGA have been already used to demonstrate the performance of these systems. In this paper we present a comparison study of these two neuro-inspired solutions. A brief description of both systems is presented and also discussions about their differences, pros and cons. PMID:22518097
Farabet, Clément; Paz, Rafael; Pérez-Carrasco, Jose; Zamarreño-Ramos, Carlos; Linares-Barranco, Alejandro; Lecun, Yann; Culurciello, Eugenio; Serrano-Gotarredona, Teresa; Linares-Barranco, Bernabe
2012-01-01
Most scene segmentation and categorization architectures for the extraction of features in images and patches make exhaustive use of 2D convolution operations for template matching, template search, and denoising. Convolutional Neural Networks (ConvNets) are one example of such architectures that can implement general-purpose bio-inspired vision systems. In standard digital computers 2D convolutions are usually expensive in terms of resource consumption and impose severe limitations for efficient real-time applications. Nevertheless, neuro-cortex inspired solutions, like dedicated Frame-Based or Frame-Free Spiking ConvNet Convolution Processors, are advancing real-time visual processing. These two approaches share the neural inspiration, but each of them solves the problem in different ways. Frame-Based ConvNets process frame by frame video information in a very robust and fast way that requires to use and share the available hardware resources (such as: multipliers, adders). Hardware resources are fixed- and time-multiplexed by fetching data in and out. Thus memory bandwidth and size is important for good performance. On the other hand, spike-based convolution processors are a frame-free alternative that is able to perform convolution of a spike-based source of visual information with very low latency, which makes ideal for very high-speed applications. However, hardware resources need to be available all the time and cannot be time-multiplexed. Thus, hardware should be modular, reconfigurable, and expansible. Hardware implementations in both VLSI custom integrated circuits (digital and analog) and FPGA have been already used to demonstrate the performance of these systems. In this paper we present a comparison study of these two neuro-inspired solutions. A brief description of both systems is presented and also discussions about their differences, pros and cons.
Slow Speed--Fast Motion: Time-Lapse Recordings in Physics Education
ERIC Educational Resources Information Center
Vollmer, Michael; Möllmann, Klaus-Peter
2018-01-01
Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s[superscript -1], allowing us to study transient physics phenomena happening…
2012-01-01
Background Metamorphosis in insects transforms the larval into an adult body plan and comprises the destruction and remodeling of larval and the generation of adult tissues. The remodeling of larval into adult muscles promises to be a genetic model for human atrophy since it is associated with dramatic alteration in cell size. Furthermore, muscle development is amenable to 3D in vivo microscopy at high cellular resolution. However, multi-dimensional image acquisition leads to sizeable amounts of data that demand novel approaches in image processing and analysis. Results To handle, visualize and quantify time-lapse datasets recorded in multiple locations, we designed a workflow comprising three major modules. First, the previously introduced TLM-converter concatenates stacks of single time-points. The second module, TLM-2D-Explorer, creates maximum intensity projections for rapid inspection and allows the temporal alignment of multiple datasets. The transition between prepupal and pupal stage serves as reference point to compare datasets of different genotypes or treatments. We demonstrate how the temporal alignment can reveal novel insights into the east gene which is involved in muscle remodeling. The third module, TLM-3D-Segmenter, performs semi-automated segmentation of selected muscle fibers over multiple frames. 3D image segmentation consists of 3 stages. First, the user places a seed into a muscle of a key frame and performs surface detection based on level-set evolution. Second, the surface is propagated to subsequent frames. Third, automated segmentation detects nuclei inside the muscle fiber. The detected surfaces can be used to visualize and quantify the dynamics of cellular remodeling. To estimate the accuracy of our segmentation method, we performed a comparison with a manually created ground truth. Key and predicted frames achieved a performance of 84% and 80%, respectively. Conclusions We describe an analysis pipeline for the efficient handling and analysis of time-series microscopy data that enhances productivity and facilitates the phenotypic characterization of genetic perturbations. Our methodology can easily be scaled up for genome-wide genetic screens using readily available resources for RNAi based gene silencing in Drosophila and other animal models. PMID:23282138
Time-series animation techniques for visualizing urban growth
Acevedo, W.; Masuoka, P.
1997-01-01
Time-series animation is a visually intuitive way to display urban growth. Animations of landuse change for the Baltimore-Washington region were generated by showing a series of images one after the other in sequential order. Before creating an animation, various issues which will affect the appearance of the animation should be considered, including the number of original data frames to use, the optimal animation display speed, the number of intermediate frames to create between the known frames, and the output media on which the animations will be displayed. To create new frames between the known years of data, the change in each theme (i.e. urban development, water bodies, transportation routes) must be characterized and an algorithm developed to create the in-between frames. Example time-series animations were created using a temporal GIS database of the Baltimore-Washington area. Creating the animations involved generating raster images of the urban development, water bodies, and principal transportation routes; overlaying the raster images on a background image; and importing the frames to a movie file. Three-dimensional perspective animations were created by draping each image over digital elevation data prior to importing the frames to a movie file. ?? 1997 Elsevier Science Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lehmann, J; The University of Sydney, Sydney; The University of Newcastle, Newcastle
Purpose: As prior work has shown that current DIBH monitoring approaches using surrogate measures (marker block on chest) do not always correspond with the clinical quantity of interest (lung depth, LD), a software tool and workflow are introduced to use MV fluoroscopy during treatment for real-time / Live EPID-based Inspiration Level Assessment (LEILA). Methods: A prototype software tool calculates and displays the LD during the treatment of left sided breast cancer. Calculations are based on MV cine images which are acquired with the treatment beam thereby not incurring any additional imaging dose. Image capture and processing are implemented using amore » dedicated frame grabber computer. The calculation engine automatically detects image orientation and includes provisions for large treatment fields that exceed the size of the EPID panel. LD is measured along a line profile in the middle of the field. LEILA’s interface displays the current MV image, a reference image (DRR), the current LD, as well as a trace of LD over treatment time. The display includes patient specific LD tolerances. Tolerances are specified for each field and loaded before the treatment. A visual warning is generated when the tolerance is exceeded. LEILA is initially run in parallel with current DIBH techniques. When later run by itself DIBH setup will be done using skin marks and room laser. Results: Offline tests of LEILA confirmed accurate automatic LD measurement for a variety of patient geometries. Deployment of the EPID during all left sided breast treatments was well tolerated by patients and staff during a multi-month pilot. The frame grabber provides 11 frames-per-second; the MATLAB based LEILA prototype software can analyze five frames-per-second standalone on standard desktop hardware. Conclusion: LEILA provides an automated approach to quantitatively monitor LD on MV images during DIBH treatment. Future improvements include a database and further speed optimization.« less
NASA Astrophysics Data System (ADS)
Guthoff, Rudolf F.; Zhivov, Andrey; Stachs, Oliver
2010-02-01
The aim of the study was to produce two-dimensional reconstruction maps of the living corneal sub-basal nerve plexus by in vivo laser scanning confocal microscopy in real time. CLSM source data (frame rate 30Hz, 384x384 pixel) were used to create large-scale maps of the scanned area by selecting the Automatic Real Time (ART) composite mode. The mapping algorithm is based on an affine transformation. Microscopy of the sub-basal nerve plexus was performed on normal and LASIK eyes as well as on rabbit eyes. Real-time mapping of the sub-basal nerve plexus was performed in large-scale up to a size of 3.2mm x 3.2mm. The developed method enables a real-time in vivo mapping of the sub-basal nerve plexus which is stringently necessary for statistically firmed conclusions about morphometric plexus alterations.
Molecular Frame Reconstruction Using Time-Domain Photoionization Interferometry.
Marceau, Claude; Makhija, Varun; Platzer, Dominique; Naumov, A Yu; Corkum, P B; Stolow, Albert; Villeneuve, D M; Hockett, Paul
2017-08-25
Photoionization of molecular species is, essentially, a multipath interferometer with both experimentally controllable and intrinsic molecular characteristics. In this work, XUV photoionization of impulsively aligned molecular targets (N_{2}) is used to provide a time-domain route to "complete" photoionization experiments, in which the rotational wave packet controls the geometric part of the photoionization interferometer. The data obtained is sufficient to determine the magnitudes and phases of the ionization matrix elements for all observed channels, and to reconstruct molecular frame interferograms from lab frame measurements. In principle, this methodology provides a time-domain route to complete photoionization experiments and the molecular frame, which is generally applicable to any molecule (no prerequisites), for all energies and ionization channels.
Design and Principles Enabling the Space Reference FOM
NASA Technical Reports Server (NTRS)
Moeller, Bjoern; Dexter, Dan; Madden, Michael; Crues, Edwin Z.; Garro, Alfredo; Skuratovskiy, Anton
2017-01-01
A first complete draft of the Simulation Interoperability Standards Organization (SISO) Space Reference Federation Object Model (FOM) has now been produced. This paper provides some insights into its capabilities and discusses the opportunity for reuse in other domains. The focus of this first version of the standard is execution control, time management and coordinate systems, well-known reference frames, as well as some basic support for physical entities. The biggest part of the execution control is the coordinated start-up process. This process contains a number of steps, including checking of required federates, handling of early versus late joiners, sharing of federation wide configuration data and multi-phase initialization. An additional part of Execution Control is the coordinated and synchronized transition between Run mode, Freeze mode and Shutdown. For time management, several time lines are defined, including real-time, scenario time, High Level Architecture (HLA) logical time and physical time. A strategy for mixing simulations that use different time steps is introduced, as well as an approach for finding common boundaries for fully synchronized freeze. For describing spatial information, a mechanism with a set of reference frames is specified. Each reference frame has a position and orientation related to a parent reference frame. This makes it possible for federates to perform calculations in reference frames that are convenient to them. An operation on the Moon can be performed using lunar coordinates whereas an operation on Earth can be performed using Earth coordinates. At the same time, coordinates in one reference frame have an unambiguous relationship to a coordinate in another reference frame. While the Space Reference FOM is originally being developed for Space operations, the authors believe that many parts of it can be reused for any simulation that has a focus on physical processes with one or more coordinate systems, and require high fidelity and repeatability.
2015-07-01
IMAGE FRAME RATE (R-x\\ IFR -n) PRE-TRIGGER FRAMES (R-x\\PTG-n) TOTAL FRAMES (R-x\\TOTF-n) EXPOSURE TIME (R-x\\EXP-n) SENSOR ROTATION (R-x...0” (Single frame). “1” (Multi-frame). “2” (Continuous). Allowed when: When R\\CDT is “IMGIN” IMAGE FRAME RATE R-x\\ IFR -n R/R Ch 10 Status: RO...the settings that the user wishes to modify. Return Value The impact : A partial IHAL <configuration> element containing only the new settings for
Living Color Frame System: PC graphics tool for data visualization
NASA Technical Reports Server (NTRS)
Truong, Long V.
1993-01-01
Living Color Frame System (LCFS) is a personal computer software tool for generating real-time graphics applications. It is highly applicable for a wide range of data visualization in virtual environment applications. Engineers often use computer graphics to enhance the interpretation of data under observation. These graphics become more complicated when 'run time' animations are required, such as found in many typical modern artificial intelligence and expert systems. Living Color Frame System solves many of these real-time graphics problems.
Lu, Yi; Yeung, Cecil; Radmanesh, Alireza; Wiemann, Robert; Black, Peter M.; Golby, Alexandra J.
2015-01-01
Objective Intraoperative MRI (IoMRI) guided brain biopsy provides a real time visual feedback of the lesion that is sampled during surgery. The objective of the study is to compare the diagnostic yield and safety profiles of ioMRI needle brain biopsy with two traditional brain biopsy methods: frame-based and frameless stereotactic brain biopsies. Methods A retrospective analysis from 288 consecutive needle brain biopsies in 277 patients undergoing stereotactic brain biopsy with any of the three biopsy methods at Brigham and Women's Hospital from 2000 to 2008 was performed. Variables such as age, sex, history of radiation and previous surgery, pathology results, complications and postoperative stays were analyzed. Results Over the course of eight years, 288 brain biopsies were performed. 253 (87.8%) biopsies yielded positive diagnostic tissue. Young age (<40 years), history of brain radiation or surgery were significant negative predictors for a positive biopsy diagnostic yield. Excluding patients with prior radiation or surgeries, no significant difference in diagnostic yield was detected among the three groups, with frame-based, frameless and ioMRI guided needle biopsies yield 96.9%, 91.8% and 89.9% positive diagnostic yield, respectively. 19 biopsies (6.6%) were complicated by serious adverse events. The ioMRI-guided brain biopsy was associated with less serious adverse events and the shortest postoperative hospital stay. Conclusions Frame-based, frameless stereotactic and ioMRI guided brain needle biopsy have comparable diagnostic yield for patients with no prior treatments (either radiation or surgery). IoMRI guided brain biopsy is associated with fewer serious adverse events and shorter hospital stay. PMID:25088233
Automatic detection of end-diastolic and end-systolic frames in 2D echocardiography.
Zolgharni, Massoud; Negoita, Madalina; Dhutia, Niti M; Mielewczik, Michael; Manoharan, Karikaran; Sohaib, S M Afzal; Finegold, Judith A; Sacchi, Stefania; Cole, Graham D; Francis, Darrel P
2017-07-01
Correctly selecting the end-diastolic and end-systolic frames on a 2D echocardiogram is important and challenging, for both human experts and automated algorithms. Manual selection is time-consuming and subject to uncertainty, and may affect the results obtained, especially for advanced measurements such as myocardial strain. We developed and evaluated algorithms which can automatically extract global and regional cardiac velocity, and identify end-diastolic and end-systolic frames. We acquired apical four-chamber 2D echocardiographic video recordings, each at least 10 heartbeats long, acquired twice at frame rates of 52 and 79 frames/s from 19 patients, yielding 38 recordings. Five experienced echocardiographers independently marked end-systolic and end-diastolic frames for the first 10 heartbeats of each recording. The automated algorithm also did this. Using the average of time points identified by five human operators as the reference gold standard, the individual operators had a root mean square difference from that gold standard of 46.5 ms. The algorithm had a root mean square difference from the human gold standard of 40.5 ms (P<.0001). Put another way, the algorithm-identified time point was an outlier in 122/564 heartbeats (21.6%), whereas the average human operator was an outlier in 254/564 heartbeats (45%). An automated algorithm can identify the end-systolic and end-diastolic frames with performance indistinguishable from that of human experts. This saves staff time, which could therefore be invested in assessing more beats, and reduces uncertainty about the reliability of the choice of frame. © 2017, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Mahmoudabadi, H.; Lercier, D.; Vielliard, S.; Mein, N.; Briggs, G.
2016-12-01
The support of time-dependent transformations for surveying and GIS is becoming a critical issue. We need to convert positions from the realizations of the International Terrestrial Reference Frame to any national reference frame. This problem is easy to solve when all of the required information is available. But it becomes really complicated in a worldwide context. We propose an overview of the current ITRF-aligned reference frames and we describe a global solution to support time-dependent transformations between them and the International Terrestrial Reference Frame. We focus on the uncertainties of station velocities used. In a first approximation, we use a global tectonic plate model to calculate point velocities. We show the impact of the velocity model on the coordinate accuracies. Several countries, particularly in active regions, are developing semi-dynamic reference frames. These frames include local displacement models updated regularly and/or after major events (such as earthquakes). Their integration into surveying or GIS applications is an upcoming challenge. We want to encourage the geodetic community to develop and use standard formats.
Five Different Types of Framing Effects in Medical Situation: A Preliminary Exploration
Peng, Jiaxi; Li, Hongzheng; Miao, Danmin; Feng, Xi; Xiao, Wei
2013-01-01
Background Considerable reports concerned the framing effect in medical situations. But quite few of them noticed to explore the differences among the various kinds of framing effects. Objectives In the present study, five different types of framing effects were examined and the effect sizes of them were compared. Materials and Methods Medical decision making problems concerning medicine effect evaluation, patient's compliance, treatment and doctor options selection were established. All the problems were described in both positive and negative frames. 500 undergraduates as participants were randomly divided into ten groups. Participants from each group were asked to finish one decision making task. Results All the frames that were examined leaded to significant framing effects: When the Asia Disease Problem was described in a positive frame, the participants preferred the conservative frame than the risky one, while if in a negative frame, the preference reversed (P < 0.01). If the drug effect was described as “of 100 patients taking this kind of medicine, 70 patients became better”, people tended to make more positive evaluations, compared with described as “of 100 patients taking this kind of medicine, 30 patients didn’t become better” (P < 0.01). Doctors’ advices were respectively described in a baneful or beneficial frame and the former one resulted in a better compliance (P < 0.05). If treatment options were described with a survival rate, people tended to choose risky option, while if described with a mortality rate, people tended to choose conservative option (P < 0.05). The number sized framing effect was also tested to be significant (P < 0.01). The five types of framing effects were small to big in effect size. Conclusions Medical decision making can be affected by frame descriptions. Attentions should be paid on the standardization of description in medical practice. PMID:23682330
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanfilippo, Antonio P.; Franklin, Lyndsey; Tratz, Stephen C.
2008-04-01
Frame Analysis has come to play an increasingly stronger role in the study of social movements in Sociology and Political Science. While significant steps have been made in providing a theory of frames and framing, a systematic characterization of the frame concept is still largely lacking and there are no rec-ognized criteria and methods that can be used to identify and marshal frame evi-dence reliably and in a time and cost effective manner. Consequently, current Frame Analysis work is still too reliant on manual annotation and subjective inter-pretation. The goal of this paper is to present an approach to themore » representation, acquisition and analysis of frame evidence which leverages Content Analysis, In-formation Extraction and Semantic Search methods to provide a systematic treat-ment of a Frame Analysis and automate frame annotation.« less
Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision Clinic
DeCarlo, Dawn K.; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia
2013-01-01
Purpose. To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. Methods. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Results. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J0 and J45 were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (−8.6 to 4.9). Conclusions. Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction. PMID:23188726
Commentary: It Is Not Only about the Computers--An Argument for Broadening the Conversation
ERIC Educational Resources Information Center
DeWitt, Scott W.
2006-01-01
In 2002 the members of the National Technology Leadership Initiative (NTLI) framed seven conclusions relating to handheld computers and ubiquitous computing in schools. While several of the conclusions are laudable efforts to increase research and professional development, the factual and conceptual bases for this document are seriously flawed.…
Updegraff, John A.; Brick, Cameron; Emanuel, Amber S.; Mintzer, Roy E.; Sherman, David K.
2015-01-01
Objective The present study examined how gain- and loss-framed informational videos about oral health influence self-reported flossing behavior over a 6-month period, as well as the roles of perceived susceptibility to oral health problems and approach/avoidance motivational orientation in moderating these effects. Method An age and ethnically diverse sample of 855 American adults were randomized to receive no health message, or either a gain-framed or loss-framed video presented on the Internet. Self-reported flossing was assessed longitudinally at 2 and 6 months. Results Among the entire sample, susceptibility interacted with frame to predict flossing. Participants who watched a video where the frame (gain/loss) matched perceived susceptibility (low/high) had significantly greater likelihood of flossing at recommended levels at the 6-month follow-up, compared with those who viewed a mismatched video or no video at all. However, young adults (18–24) showed stronger moderation by motivational orientation than by perceived susceptibility, in line with previous work largely conducted with young adult samples. Conclusion Brief informational interventions can influence long-term health behavior, particularly when the gain- or loss-frame of the information matches the recipient’s beliefs about their health outcome risks. PMID:25020153
Effects of the frame acquisition rate on the sensitivity of gastro-oesophageal reflux scintigraphy
Codreanu, I; Chamroonrat, W; Edwards, K
2013-01-01
Objective: To compare the sensitivity of gastro-oesophageal reflux (GOR) scintigraphy at 5-s and 60-s frame acquisition rates. Methods: GOR scintigraphy of 50 subjects (1 month–20 years old, mean 42 months) were analysed concurrently using 5-s and 60-s acquisition frames. Reflux episodes were graded as low if activity was detected in the distal half of the oesophagus and high if activity was detected in its upper half or in the oral cavity. For comparison purposes, detected GOR in any number of 5-s frames corresponding to one 60-s frame was counted as one episode. Results: A total of 679 episodes of GOR to the upper oesophagus were counted using a 5-s acquisition technique. Only 183 of such episodes were detected on 60-s acquisition images. To the lower oesophagus, a total of 1749 GOR episodes were detected using a 5-s acquisition technique and only 1045 episodes using 60-s acquisition frames (these also included the high-level GOR on 5-s frames counted as low level on 60-s acquisition frames). 10 patients had high-level GOR episodes that were detected only using a 5-s acquisition technique, leading to a different diagnosis in these patients. No correlation between the number of reflux episodes and the gastric emptying rates was noted. Conclusion: The 5-s frame acquisition technique is more sensitive than the 60-s frame acquisition technique for detecting both high- and low-level GOR. Advances in knowledge: Brief GOR episodes with a relatively low number of radioactive counts are frequently indistinguishable from intense background activity on 60-s acquisition frames. PMID:23520226
Barr, Margo L; Ferguson, Raymond A; Steel, David G
2014-08-12
Since 1997, the NSW Population Health Survey (NSWPHS) had selected the sample using random digit dialing of landline telephone numbers. When the survey began coverage of the population by landline phone frames was high (96%). As landline coverage in Australia has declined and continues to do so, in 2012, a sample of mobile telephone numbers was added to the survey using an overlapping dual-frame design. Details of the methodology are published elsewhere. This paper discusses the impacts of the sampling frame change on the time series, and provides possible approaches to handling these impacts. Prevalence estimates were calculated for type of phone-use, and a range of health indicators. Prevalence ratios (PR) for each of the health indicators were also calculated using Poisson regression analysis with robust variance estimation by type of phone-use. Health estimates for 2012 were compared to 2011. The full time series was examined for selected health indicators. It was estimated from the 2012 NSWPHS that 20.0% of the NSW population were mobile-only phone users. Looking at the full time series for overweight or obese and current smoking if the NSWPHS had continued to be undertaken only using a landline frame, overweight or obese would have been shown to continue to increase and current smoking would have been shown to continue to decrease. However, with the introduction of the overlapping dual-frame design in 2012, overweight or obese increased until 2011 and then decreased in 2012, and current smoking decreased until 2011, and then increased in 2012. Our examination of these time series showed that the changes were a consequence of the sampling frame change and were not real changes. Both the backcasting method and the minimal coverage method could adequately adjust for the design change and allow for the continuation of the time series. The inclusion of the mobile telephone numbers, through an overlapping dual-frame design, did impact on the time series for some of the health indicators collected through the NSWPHS, but only in that it corrected the estimates that were being calculated from a sample frame that was progressively covering less of the population.
Media framing and construction of childhood obesity: a content analysis of Swedish newspapers.
van Hooft, J; Patterson, C; Löf, M; Alexandrou, C; Hilton, S; Nimegeer, A
2018-02-01
Despite lower prevalence than most European countries, childhood obesity is a Swedish public health priority due to its lasting health impacts and socioeconomic patterning. Mass media content influences public and political perceptions of health issues, and media framing of childhood obesity may influence perceptions of its solutions. This study examines framing of childhood obesity in Swedish morning and evening newspapers from 1996 to 2014. Content analysis of 726 articles about childhood obesity published in the five most-circulated Swedish newspapers. Article content coded quantitatively and subjected to statistical analysis, describing relationships between themes and trends over time. Childhood obesity was consistently problematised, primarily in health terms, and linked to socio-economic and geographical factors. The yearly frequency of articles peaked in 2004, followed by a decline, corresponding with evidence about prevalence. Childhood obesity was framed as being driven by individual behaviours more frequently than structural or environmental factors. Structural framings increased over time, but constructions of the problem as driven by individual behaviours, particularly parenting, remained prominent. A relative growth in structural framings of causes and solutions over time, combined with prominent coverage of socio-economic inequalities, might be indicative of public and political amenability towards societal-level solutions, but individual behaviours remain prominent in framing of the issue. Health advocates might incorporate these insights into media engagement.
Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarvis, Lesley A., E-mail: Lesley.a.jarvis@hitchcock.org; Norris Cotton Cancer Center at the Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire; Zhang, Rongxiao
Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans,more » mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
... frames, door frames, solar panels, curtain walls, or furniture. Such parts that otherwise meet the... the time of entry, such as finished windows with glass, doors, picture frames, and solar panels. The...
Development of two-framing camera with large format and ultrahigh speed
NASA Astrophysics Data System (ADS)
Jiang, Xiaoguo; Wang, Yuan; Wang, Yi
2012-10-01
High-speed imaging facility is important and necessary for the formation of time-resolved measurement system with multi-framing capability. The framing camera which satisfies the demands of both high speed and large format needs to be specially developed in the ultrahigh speed research field. A two-framing camera system with high sensitivity and time-resolution has been developed and used for the diagnosis of electron beam parameters of Dragon-I linear induction accelerator (LIA). The camera system, which adopts the principle of light beam splitting in the image space behind the lens with long focus length, mainly consists of lens-coupled gated image intensifier, CCD camera and high-speed shutter trigger device based on the programmable integrated circuit. The fastest gating time is about 3 ns, and the interval time between the two frames can be adjusted discretely at the step of 0.5 ns. Both the gating time and the interval time can be tuned to the maximum value of about 1 s independently. Two images with the size of 1024×1024 for each can be captured simultaneously in our developed camera. Besides, this camera system possesses a good linearity, uniform spatial response and an equivalent background illumination as low as 5 electrons/pix/sec, which fully meets the measurement requirements of Dragon-I LIA.
Mays, Darren; Niaura, Raymond S.; Evans, W. Douglas; Hammond, David; Luta, George; Tercyak, Kenneth P.
2014-01-01
Objective This study examined the impact of pictorial cigarette warning labels, warning label message framing, and plain cigarette packaging on young adult smokers’ motivation to quit. Methods Smokers ages 18–30 (n=740) from a consumer research panel were randomized to one of four experimental conditions where they viewed online images of 4 cigarette packs with warnings about lung disease, cancer, stroke/heart disease, and death, respectively. Packs differed across conditions by warning message framing (gain versus loss) and packaging (branded versus plain). Measures captured demographics, smoking behavior, covariates, and motivation to quit in response to cigarette packs. Results Pictorial warnings about lung disease and cancer generated the strongest motivation to quit across conditions. Adjusting for pre-test motivation and covariates, a message framing by packaging interaction revealed gain-framed warnings on plain packs generated greater motivation to quit for lung disease, cancer, and mortality warnings (p < 0.05), compared with loss-framed warnings on plain packs. Conclusions Warnings combining pictorial depictions of smoking-related health risks with text-based messages about how quitting reduces risks may achieve better outcomes among young adults, especially in countries considering or implementing plain packaging regulations. PMID:24420310
NASA Astrophysics Data System (ADS)
Xie, Yi; Kopeikin, Sergei Affiliaiton: AB(Department of Physics and Astronomy, University of Missouri, USA kopeikins@missouri.edu)
2010-08-01
We overview a set of post-Newtonian reference frames for a comprehensive study of the orbital dynamics and rotational motion of Moon and Earth by means of lunar laser ranging (LLR). We employ a scalar-tensor theory of gravity depending on two post-Newtonian parameters, and , and utilize the relativistic resolutions on reference frames adopted by the International Astronomical Union (IAU) in 2000. We assume that the solar system is isolated and space-time is asymptotically flat at infinity. The primary reference frame covers the entire space-time, has its origin at the solar-system barycenter (SSB) and spatial axes stretching up to infinity. The SSB frame is not rotating with respect to a set of distant quasars that are forming the International Celestial Reference Frame (ICRF). The secondary reference frame has its origin at the Earth-Moon barycenter (EMB). The EMB frame is locally-inertial and is not rotating dynamically in the sense that equation of motion of a test particle moving with respect to the EMB frame, does not contain the Coriolis and centripetal forces. Two other local frames geocentric (GRF) and selenocentric (SRF) have their origins at the center of mass of Earth and Moon respectively and do not rotate dynamically. Each local frame is subject to the geodetic precession both with respect to other local frames and with respect to the ICRF because of their relative motion with respect to each other. Theoretical advantage of the dynamically non-rotating local frames is in a more simple mathematical description. Each local frame can be aligned with the axes of ICRF after applying the matrix of the relativistic precession. The set of one global and three local frames is introduced in order to fully decouple the relative motion of Moon with respect to Earth from the orbital motion of the Earth-Moon barycenter as well as to connect the coordinate description of the lunar motion, an observer on Earth, and a retro-reflector on Moon to directly measurable quantities such as the proper time and the round-trip laser-light distance. We solve the gravity field equations and find out the metric tensor and the scalar field in all frames which description includes the post-Newtonian multipole moments of the gravitational field of Earth and Moon. We also derive the post-Newtonian coordinate transformations between the frames and analyze the residual gauge freedom.
Report of the panel on earth rotation and reference frames, section 7
NASA Technical Reports Server (NTRS)
Dickey, Jean O.; Dickman, Steven R.; Eubanks, Marshall T.; Feissel, Martine; Herring, Thomas A.; Mueller, Ivan I.; Rosen, Richard D.; Schutz, Robert E.; Wahr, John M.; Wilson, Charles R.
1991-01-01
Objectives and requirements for Earth rotation and reference frame studies in the 1990s are discussed. The objectives are to observe and understand interactions of air and water with the rotational dynamics of the Earth, the effects of the Earth's crust and mantle on the dynamics and excitation of Earth rotation variations over time scales of hours to centuries, and the effects of the Earth's core on the rotational dynamics and the excitation of Earth rotation variations over time scales of a year or longer. Another objective is to establish, refine and maintain terrestrial and celestrial reference frames. Requirements include improvements in observations and analysis, improvements in celestial and terrestrial reference frames and reference frame connections, and improved observations of crustal motion and mass redistribution on the Earth.
NASA Technical Reports Server (NTRS)
Ghosh, Amrit Raj
1996-01-01
The viscous, Navier-Stokes solver for turbomachinery applications, MSUTC has been modified to include the rotating frame formulation. The three-dimensional thin-layer Navier-Stokes equations have been cast in a rotating Cartesian frame enabling the freezing of grid motion. This also allows the flow-field associated with an isolated rotor to be viewed as a steady-state problem. Consequently, local time stepping can be used to accelerate convergence. The formulation is validated by running NASA's Rotor 67 as the test case. results are compared between the rotating frame code and the absolute frame code. The use of the rotating frame approach greatly enhances the performance of the code with respect to savings in computing time, without degradation of the solution.
Column descriptions ID : Unique integer for each control time simulation LABEL : Description unique to each ID (see paper) Z : Redshift TIMEAREA : Observer-frame control time x area at 'Z' (year-arcmin ^2) Z2 : Second redshift TIMEVOL : Total rest-frame control time x volume between 'Z' and 'Z2' (year
NASA Astrophysics Data System (ADS)
Barreto, A. B.; Pucheu, M. L.; Romero, C.
2018-02-01
We consider scalar–tensor theories of gravity defined in Weyl integrable space-time and show that for time-lapse extended Robertson–Walker metrics in the ADM formalism a class of Weyl transformations corresponding to change of frames induce canonical transformations between different representations of the phase space. In this context, we discuss the physical equivalence of two distinct Weyl frames at the classical level.
The influence of visual and vestibular orientation cues in a clock reading task.
Davidenko, Nicolas; Cheong, Yeram; Waterman, Amanda; Smith, Jacob; Anderson, Barrett; Harmon, Sarah
2018-05-23
We investigated how performance in the real-life perceptual task of analog clock reading is influenced by the clock's orientation with respect to egocentric, gravitational, and visual-environmental reference frames. In Experiment 1, we designed a simple clock-reading task and found that observers' reaction time to correctly tell the time depends systematically on the clock's orientation. In Experiment 2, we dissociated egocentric from environmental reference frames by having participants sit upright or lie sideways while performing the task. We found that both reference frames substantially contribute to response times in this task. In Experiment 3, we placed upright or rotated participants in an upright or rotated immersive virtual environment, which allowed us to further dissociate vestibular from visual cues to the environmental reference frame. We found evidence of environmental reference frame effects only when visual and vestibular cues were aligned. We discuss the implications for the design of remote and head-mounted displays. Copyright © 2018 Elsevier Inc. All rights reserved.
Bisi, Maria Cristina; Stagni, Rita; Caroselli, Alessio; Cappello, Angelo
2015-08-01
Inertial sensors are becoming widely used for the assessment of human movement in both clinical and research applications, thanks to their usability out of the laboratory. This work aims to propose a method for calibrating anatomical landmark position in the wearable sensor reference frame with an ease to use, portable and low cost device. An off-the-shelf camera, a stick and a pattern, attached to the inertial sensor, compose the device. The proposed technique is referred to as video Calibrated Anatomical System Technique (vCAST). The absolute orientation of a synthetic femur was tracked both using the vCAST together with an inertial sensor and using stereo-photogrammetry as reference. Anatomical landmark calibration showed mean absolute error of 0.6±0.5 mm: these errors are smaller than those affecting the in-vivo identification of anatomical landmarks. The roll, pitch and yaw anatomical frame orientations showed root mean square errors close to the accuracy limit of the wearable sensor used (1°), highlighting the reliability of the proposed technique. In conclusion, the present paper proposes and preliminarily verifies the performance of a method (vCAST) for calibrating anatomical landmark position in the wearable sensor reference frame: the technique is low time consuming, highly portable, easy to implement and usable outside laboratory. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
SarcOptiM for ImageJ: high-frequency online sarcomere length computing on stimulated cardiomyocytes.
Pasqualin, Côme; Gannier, François; Yu, Angèle; Malécot, Claire O; Bredeloux, Pierre; Maupoil, Véronique
2016-08-01
Accurate measurement of cardiomyocyte contraction is a critical issue for scientists working on cardiac physiology and physiopathology of diseases implying contraction impairment. Cardiomyocytes contraction can be quantified by measuring sarcomere length, but few tools are available for this, and none is freely distributed. We developed a plug-in (SarcOptiM) for the ImageJ/Fiji image analysis platform developed by the National Institutes of Health. SarcOptiM computes sarcomere length via fast Fourier transform analysis of video frames captured or displayed in ImageJ and thus is not tied to a dedicated video camera. It can work in real time or offline, the latter overcoming rotating motion or displacement-related artifacts. SarcOptiM includes a simulator and video generator of cardiomyocyte contraction. Acquisition parameters, such as pixel size and camera frame rate, were tested with both experimental recordings of rat ventricular cardiomyocytes and synthetic videos. It is freely distributed, and its source code is available. It works under Windows, Mac, or Linux operating systems. The camera speed is the limiting factor, since the algorithm can compute online sarcomere shortening at frame rates >10 kHz. In conclusion, SarcOptiM is a free and validated user-friendly tool for studying cardiomyocyte contraction in all species, including human. Copyright © 2016 the American Physiological Society.
NASA Astrophysics Data System (ADS)
Luo, Ji
2012-08-01
Quantitative transformations between corresponding kinetic quantities defined by any two spatial referential frames, whose relative kinematics relations (purely rotational and translational movement) are known, are presented based on necessarily descriptive definitions of the fundamental concepts (instant, time, spatial referential frame that distinguishes from Maths. Coordination, physical point) had being clarified by directly empirical observation with artificially descriptive purpose. Inductive investigation of the transformation reveals that all physical quantities such as charge, temperature, time, volume, length, temporal rate of the quantities and relations like temporal relation between signal source and observer as such are independent to spatial frames transformation except above kinematical quantities transformations, kinematics related dynamics such as Newton ’ s second law existing only in inertial frames and exchange of kinetic energy of mass being valid only in a selected inertial frame. From above bas is, we demonstrate a series of inferences and applications such as phase velocity of light being direct respect to medium (including vacuum) rather than to the frame, using spatial referential frame to describe any measurable field (electric field, magnetic field, gravitational field) and the field ’ s variation; and have tables to contrast and evaluate all aspects of those hypotheses related with spacetime such as distorted spacetime around massive stellar, four dimension spacetime, gravitational time dilation and non - Euclid geometry with new one. The demonstration strongly suggests all the hypotheses are invalid in capable tested concepts ’ meaning and relations. The conventional work on frame transformation and its property, hypothesized by Voigt, Heaviside, Lorentz, Poincare and Einstein a century ago with some mathematical speculation lacking rigorous definition of the fundamental concepts such as instant, time, spatial reference, straight line, plane area, merely good in building up patchwork to do self p referred explanation by making up derivative concepts or accumulating new hypothesis, has disturbed people to describe the physical nature by setting up the sound basis of concept and relations with capable tested method, it’s time to be replaced by empirically effective alternative.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sapoval, Marc, E-mail: marc.sapoval2@egp.aphp.fr; Pellerin, Olivier; Rehel, Jean-Luc
The purpose of this study was to assess the ability of low-dose/low-frame fluoroscopy/angiography with a flat-panel detector angiographic suite to reduce the dose delivered to patients during uterine fibroid embolization (UFE). A two-step prospective dosimetric study was conducted, with a flat-panel detector angiography suite (Siemens Axiom Artis) integrating automatic exposure control (AEC), during 20 consecutive UFEs. Patient dosimetry was performed using calibrated thermoluminescent dosimeters placed on the lower posterior pelvis skin. The first step (10 patients; group A) consisted in UFE (bilateral embolization, calibrated microspheres) performed using the following parameters: standard fluoroscopy (15 pulses/s) and angiography (3 frames/s). The secondmore » step (next consecutive 10 patients; group B) used low-dose/low-frame fluoroscopy (7.5 pulses/s for catheterization and 3 pulses/s for embolization) and angiography (1 frame/s). We also recorded the total dose-area product (DAP) delivered to the patient and the fluoroscopy time as reported by the manufacturer's dosimetry report. The mean peak skin dose decreased from 2.4 {+-} 1.3 to 0.4 {+-} 0.3 Gy (P = 0.001) for groups A and B, respectively. The DAP values decreased from 43,113 {+-} 27,207 {mu}Gy m{sup 2} for group A to 9,515 {+-} 4,520 {mu}Gy m{sup 2} for group B (P = 0.003). The dose to ovaries and uterus decreased from 378 {+-} 238 mGy (group A) to 83 {+-} 41 mGy (group B) and from 388 {+-} 246 mGy (group A) to 85 {+-} 39 mGy (group B), respectively. Effective doses decreased from 112 {+-} 71 mSv (group A) to 24 {+-} 12 mSv (group B) (P = 0.003). In conclusion, the use of low-dose/low-frame fluoroscopy/angiography, based on a good understanding of the AEC system and also on the technique during uterine fibroid embolization, allows a significant decrease in the dose exposure to the patient.« less
Benjaminy, Shelly; MacDonald, Ian; Bubela, Tania
2014-01-01
Purpose: Ocular gene transfer clinical trials are raising patient hopes for the treatment of choroideremia – a blinding degenerative retinopathy. Phase I choroideremia gene transfer trials necessitate communicating about the risks of harm and potential benefits with patients while avoiding the sensationalism that has historically undermined this field of translational medicine. Methods: We conducted interviews between June 2011 and June 2012 with 6 choroideremia patient advocates, 20 patients, and 15 clinicians about their hopes for benefits, perceived risks of harm, and hopes for the time frame of clinical implementation of choroideremia gene transfer. Results: Despite the safety focus of phase I trials, participants hoped for direct visual benefits with evident discrepancies between stakeholder perspectives about the degree of visual benefit. Clinicians and patient advocates were concerned by limited patient attention to risks of harm. Interviews revealed confusion about the time frames for the clinical implementation of choroideremia gene transfer and patient urgency to access gene transfer within a limited therapeutic window. Conclusion: Differences in stakeholder perspectives about choroideremia gene transfer necessitate strategies that promote responsible communications about choroideremia gene transfer and aid in its translation. Strategies should counter historical sensationalism associated with gene transfer, promote informed consent, and honor patient hope while grounding communications in current clinical realities. PMID:24071795
Role of optometry school in single day large scale school vision testing
Anuradha, N; Ramani, Krishnakumar
2015-01-01
Background: School vision testing aims at identification and management of refractive errors. Large-scale school vision testing using conventional methods is time-consuming and demands a lot of chair time from the eye care professionals. A new strategy involving a school of optometry in single day large scale school vision testing is discussed. Aim: The aim was to describe a new approach of performing vision testing of school children on a large scale in a single day. Materials and Methods: A single day vision testing strategy was implemented wherein 123 members (20 teams comprising optometry students and headed by optometrists) conducted vision testing for children in 51 schools. School vision testing included basic vision screening, refraction, frame measurements, frame choice and referrals for other ocular problems. Results: A total of 12448 children were screened, among whom 420 (3.37%) were identified to have refractive errors. 28 (1.26%) children belonged to the primary, 163 to middle (9.80%), 129 (4.67%) to secondary and 100 (1.73%) to the higher secondary levels of education respectively. 265 (2.12%) children were referred for further evaluation. Conclusion: Single day large scale school vision testing can be adopted by schools of optometry to reach a higher number of children within a short span. PMID:25709271
Time evolution of an SLR reference frame
NASA Astrophysics Data System (ADS)
Angermann, D.; Gerstl, M.; Kelm, R.; Müller, H.; Seemüller, W.; Vei, M.
2002-07-01
On the basis of LAGEOS-1 and LAGEOS-2 data we computed a 10-years (1990-2000) solution for SLR station positions and velocities. The paper describes the data processing with the DGFI software package DOGS. We present results for station coordinates and their time variation for 41 stations of the global SLR network, and discuss the stability and time evolution of the SLR reference frame established in the same way. We applied different methods to assess the quality and consistency of the SLR results. The results presented in this paper include: (1) a time series of weekly estimated station coordinates; (2) a comparison of a 10-year LAGEOS-1 and LAGEOS-2 solution; (3) a comparison of 2.5-year solutions with the combined 10-year solution to assess the internal stability and the time evolution of the SLR reference frame; (4) a comparison of the SLR reference frame with ITRF97; and (5) a comparison of SLR station velocities with those of ITRF97 and NNR NUVEL-1A.
Bicycle weight and commuting time: randomised trial.
Groves, J
2010-12-09
To determine whether the author's 20.9 lb (9.5 kg) carbon frame bicycle reduced commuting time compared with his 29.75 lb (13.5 kg) steel frame bicycle. Randomised trial. Sheffield and Chesterfield, United Kingdom, between mid-January 2010 and mid-July 2010. One consultant in anaesthesia and intensive care. Total time to complete the 27 mile (43.5 kilometre) journey from Sheffield to Chesterfield Royal Hospital and back. The total distance travelled on the steel frame bicycle during the study period was 809 miles (1302 km) and on the carbon frame bicycle was 711 miles (1144 km). The difference in the mean journey time between the steel and carbon bicycles was 00:00:32 (hr:min:sec; 95% CI -00:03:34 to 00:02:30; P=0.72). A lighter bicycle did not lead to a detectable difference in commuting time. Cyclists may find it more cost effective to reduce their own weight rather than to purchase a lighter bicycle.
Program Helps Generate And Manage Graphics
NASA Technical Reports Server (NTRS)
Truong, L. V.
1994-01-01
Living Color Frame Maker (LCFM) computer program generates computer-graphics frames. Graphical frames saved as text files, in readable and disclosed format, easily retrieved and manipulated by user programs for wide range of real-time visual information applications. LCFM implemented in frame-based expert system for visual aids in management of systems. Monitoring, diagnosis, and/or control, diagrams of circuits or systems brought to "life" by use of designated video colors and intensities to symbolize status of hardware components (via real-time feedback from sensors). Status of systems can be displayed. Written in C++ using Borland C++ 2.0 compiler for IBM PC-series computers and compatible computers running MS-DOS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duchaineau, M.; Wolinsky, M.; Sigeti, D.E.
Terrain visualization is a difficult problem for applications requiring accurate images of large datasets at high frame rates, such as flight simulation and ground-based aircraft testing using synthetic sensor stimulation. On current graphics hardware, the problem is to maintain dynamic, view-dependent triangle meshes and texture maps that produce good images at the required frame rate. We present an algorithm for constructing triangle meshes that optimizes flexible view-dependent error metrics, produces guaranteed error bounds, achieves specified triangle counts directly, and uses frame-to-frame coherence to operate at high frame rates for thousands of triangles per frame. Our method, dubbed Real-time Optimally Adaptingmore » Meshes (ROAM), uses two priority queues to drive split and merge operations that maintain continuous triangulations built from pre-processed bintree triangles. We introduce two additional performance optimizations: incremental triangle stripping and priority-computation deferral lists. ROAM execution time is proportionate to the number of triangle changes per frame, which is typically a few percent of the output mesh size, hence ROAM performance is insensitive to the resolution and extent of the input terrain. Dynamic terrain and simple vertex morphing are supported.« less
Is conscious perception a series of discrete temporal frames?
White, Peter A
2018-04-01
This paper reviews proposals that conscious perception consists, in whole or part, of successive discrete temporal frames on the sub-second time scale, each frame containing information registered as simultaneous or static. Although the idea of discrete frames in conscious perception cannot be regarded as falsified, there are many problems. Evidence does not consistently support any proposed duration or range of durations for frames. EEG waveforms provide evidence of periodicity in brain activity, but not necessarily in conscious perception. Temporal properties of perceptual processes are flexible in response to competing processing demands, which is hard to reconcile with the relative inflexibility of regular frames. There are also problems concerning the definition of frames, the need for informational connections between frames, the means by which boundaries between frames are established, and the apparent requirement for a storage buffer for information awaiting entry to the next frame. Copyright © 2018 Elsevier Inc. All rights reserved.
Rahm, Alanna Kulchak; Dearing, James; Feigelson, Heather Spencer; Tracer, David; Bull, Sheana
2011-01-01
Background Information about genetics and the promise of genomic medicine is commonplace in the mass media. How the mass media themselves contribute – or not – to the persistence of this issue and its perception by the public is the topic of this presentation. The purpose of this study is to investigate the structural and individual perspectives on the issue of direct-to-consumer (DTC) genetics, and assess the degree of correspondence across these perspectives. Methods I conducted a media analysis to determine how the issue of DTC genetics has been framed in mass media stories and the salient topics related to the issue. I conducted focus groups to determine individual knowledge, attitudes and beliefs about the issue of DTC genetics. Results A final sample of 398 mass media stories of DTC genetics from Lexis-Nexis Academic archives between September 1, 2007 and September 30, 2009 were coded for salience and frames. Fourteen focus groups were conducted between October, 2009 and March, 2010 with Kaiser Permanente Colorado members and medical staff. Focus group transcripts were coded for salience and framing of the issue and compared with the media analysis results.Study results found that the issue of DTC genetics was not very important to focus group participants except as it related to the topic of breast cancer. Mass media message topics and frames showed differences over time. Focus group participants were generally negative towards the issue while the mass media was mostly positive towards DTC genetics. Focus group participants used some of the many frames to understand the issue that were utilized by the mass media to package the issue, but participants mainly framed the issue in terms of prevention and a pandora’s box, while the mass media presented the issue more in terms of progressive and discrimination frames. Conclusions The mass media appears to function as a field of power for the issue of DTC genetics with the consumers in the middle of the contests. A higher-level concept of an “informed consumer” emerged from the focus groups that appears to provide consumers a degree of power in this battlefield as well.
NASA Astrophysics Data System (ADS)
Brown, Matthew J.
2014-02-01
The framework of quantum frames can help unravel some of the interpretive difficulties i the foundation of quantum mechanics. In this paper, I begin by tracing the origins of this concept in Bohr's discussion of quantum theory and his theory of complementarity. Engaging with various interpreters and followers of Bohr, I argue that the correct account of quantum frames must be extended beyond literal space-time reference frames to frames defined by relations between a quantum system and the exosystem or external physical frame, of which measurement contexts are a particularly important example. This approach provides superior solutions to key EPR-type measurement and locality paradoxes.
Identifying Issue Frames in Text
Sagi, Eyal; Diermeier, Daniel; Kaufmann, Stefan
2013-01-01
Framing, the effect of context on cognitive processes, is a prominent topic of research in psychology and public opinion research. Research on framing has traditionally relied on controlled experiments and manually annotated document collections. In this paper we present a method that allows for quantifying the relative strengths of competing linguistic frames based on corpus analysis. This method requires little human intervention and can therefore be efficiently applied to large bodies of text. We demonstrate its effectiveness by tracking changes in the framing of terror over time and comparing the framing of abortion by Democrats and Republicans in the U.S. PMID:23874909
Lightner, Aaron D.
2017-01-01
Many studies have documented framing effects in economic games. These studies, however, have tended to use minimal framing cues (e.g. a single sentence labelling the frame), and the frames did not involve unambiguous offer expectations. Results often did not differ substantially from those in the unframed games. Here we test the hypothesis that, in contrast to the modal offer in the unframed ultimatum game (UG) (e.g. 60% to the proposer and 40% to the responder), offers in a UG explicitly framed either as a currency exchange or a windfall will closely conform to expectations for the frame and diverge substantially from the modal offer. Participants recruited from MTurk were randomized into one of two conditions. In the control condition, participants played a standard UG. In the treatment conditions, players were provided a vignette explicitly describing the frame with their roles: some were customers and bankers in a currency exchange, and others were in a windfall scenario. We predicted (i) that modal offers in the currency exchange would involve an asymmetric split where greater than 80% went to customers and less than 20% went to bankers, and (ii) that variation in windfall offers would converge onto a 50–50 split with significantly less variation than the control condition. Our first prediction was confirmed with substantial effect sizes (d = 1.09 and d = −2.04), whereas we found no evidence for our second prediction. The first result provides further evidence that it is difficult to draw firm conclusions about economic decision-making from decontextualized games. PMID:29308218
Lightner, Aaron D; Barclay, Pat; Hagen, Edward H
2017-12-01
Many studies have documented framing effects in economic games. These studies, however, have tended to use minimal framing cues (e.g. a single sentence labelling the frame), and the frames did not involve unambiguous offer expectations. Results often did not differ substantially from those in the unframed games. Here we test the hypothesis that, in contrast to the modal offer in the unframed ultimatum game (UG) (e.g. 60% to the proposer and 40% to the responder), offers in a UG explicitly framed either as a currency exchange or a windfall will closely conform to expectations for the frame and diverge substantially from the modal offer. Participants recruited from MTurk were randomized into one of two conditions. In the control condition, participants played a standard UG. In the treatment conditions, players were provided a vignette explicitly describing the frame with their roles: some were customers and bankers in a currency exchange, and others were in a windfall scenario. We predicted (i) that modal offers in the currency exchange would involve an asymmetric split where greater than 80% went to customers and less than 20% went to bankers, and (ii) that variation in windfall offers would converge onto a 50-50 split with significantly less variation than the control condition. Our first prediction was confirmed with substantial effect sizes ( d = 1.09 and d = -2.04), whereas we found no evidence for our second prediction. The first result provides further evidence that it is difficult to draw firm conclusions about economic decision-making from decontextualized games.
Noise reduction in single time frame optical DNA maps
Müller, Vilhelm; Westerlund, Fredrik
2017-01-01
In optical DNA mapping technologies sequence-specific intensity variations (DNA barcodes) along stretched and stained DNA molecules are produced. These “fingerprints” of the underlying DNA sequence have a resolution of the order one kilobasepairs and the stretching of the DNA molecules are performed by surface adsorption or nano-channel setups. A post-processing challenge for nano-channel based methods, due to local and global random movement of the DNA molecule during imaging, is how to align different time frames in order to produce reproducible time-averaged DNA barcodes. The current solutions to this challenge are computationally rather slow. With high-throughput applications in mind, we here introduce a parameter-free method for filtering a single time frame noisy barcode (snap-shot optical map), measured in a fraction of a second. By using only a single time frame barcode we circumvent the need for post-processing alignment. We demonstrate that our method is successful at providing filtered barcodes which are less noisy and more similar to time averaged barcodes. The method is based on the application of a low-pass filter on a single noisy barcode using the width of the Point Spread Function of the system as a unique, and known, filtering parameter. We find that after applying our method, the Pearson correlation coefficient (a real number in the range from -1 to 1) between the single time-frame barcode and the time average of the aligned kymograph increases significantly, roughly by 0.2 on average. By comparing to a database of more than 3000 theoretical plasmid barcodes we show that the capabilities to identify plasmids is improved by filtering single time-frame barcodes compared to the unfiltered analogues. Since snap-shot experiments and computational time using our method both are less than a second, this study opens up for high throughput optical DNA mapping with improved reproducibility. PMID:28640821
Di Perri, Carol; Amico, Enrico; Heine, Lizette; Annen, Jitka; Martial, Charlotte; Larroque, Stephen Karl; Soddu, Andrea; Marinazzo, Daniele; Laureys, Steven
2018-01-01
Given that recent research has shown that functional connectivity is not a static phenomenon, we aim to investigate the dynamic properties of the default mode network's (DMN) connectivity in patients with disorders of consciousness. Resting-state fMRI volumes of a convenience sample of 17 patients in unresponsive wakefulness syndrome (UWS) and controls were reduced to a spatiotemporal point process by selecting critical time points in the posterior cingulate cortex (PCC). Spatial clustering was performed on the extracted PCC time frames to obtain 8 different co-activation patterns (CAPs). We investigated spatial connectivity patterns positively and negatively correlated with PCC using both CAPs and standard stationary method. We calculated CAPs occurrences and the total number of frames. Compared to controls, patients showed (i) decreased within-network positive correlations and between-network negative correlations, (ii) emergence of "pathological" within-network negative correlations and between-network positive correlations (better defined with CAPs), and (iii) "pathological" increases in within-network positive correlations and between-network negative correlations (only detectable using CAPs). Patients showed decreased occurrence of DMN-like CAPs (1-2) compared to controls. No between-group differences were observed in the total number of frames CONCLUSION: CAPs reveal at a more fine-grained level the multifaceted spatial connectivity reconfiguration following the DMN disruption in UWS patients, which is more complex than previously thought and suggests alternative anatomical substrates for consciousness. BOLD fluctuations do not seem to differ between patients and controls, suggesting that BOLD response represents an intrinsic feature of the signal, and therefore that spatial configuration is more important for consciousness than BOLD activation itself. Hum Brain Mapp 39:89-103, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
A study of applications scribe frame data verifications using design rule check
NASA Astrophysics Data System (ADS)
Saito, Shoko; Miyazaki, Masaru; Sakurai, Mitsuo; Itoh, Takahisa; Doi, Kazumasa; Sakurai, Norioko; Okada, Tomoyuki
2013-06-01
In semiconductor manufacturing, scribe frame data generally is generated for each LSI product according to its specific process design. Scribe frame data is designed based on definition tables of scanner alignment, wafer inspection and customers specified marks. We check that scribe frame design is conforming to specification of alignment and inspection marks at the end. Recently, in COT (customer owned tooling) business or new technology development, there is no effective verification method for the scribe frame data, and we take a lot of time to work on verification. Therefore, we tried to establish new verification method of scribe frame data by applying pattern matching and DRC (Design Rule Check) which is used in device verification. We would like to show scheme of the scribe frame data verification using DRC which we tried to apply. First, verification rules are created based on specifications of scanner, inspection and others, and a mark library is also created for pattern matching. Next, DRC verification is performed to scribe frame data. Then the DRC verification includes pattern matching using mark library. As a result, our experiments demonstrated that by use of pattern matching and DRC verification our new method can yield speed improvements of more than 12 percent compared to the conventional mark checks by visual inspection and the inspection time can be reduced to less than 5 percent if multi-CPU processing is used. Our method delivers both short processing time and excellent accuracy when checking many marks. It is easy to maintain and provides an easy way for COT customers to use original marks. We believe that our new DRC verification method for scribe frame data is indispensable and mutually beneficial.
NChina16: A stable geodetic reference frame for geological hazard studies in North China
NASA Astrophysics Data System (ADS)
Wang, Guoquan; Bao, Yan; Gan, Weijun; Geng, Jianghui; Xiao, Gengru; Shen, Jack S.
2018-04-01
We have developed a stable North China Reference Frame 2016 (NChina16) using five years of continuous GPS observations (2011.8-2016.8) from 12 continuously operating reference stations (CORS) fixed to the North China Craton. Applications of NChina16 in landslide and subsidence studies are illustrated in this article. A method for realizing a regional geodetic reference frame is introduced. The primary result of this study is the seven parameters for transforming Cartesian ECEF (Earth-Centered, Earth-Fixed) coordinates X, Y, and Z from the International GNSS Service Reference Frame 2008 (IGS08) to NChina16. The seven parameters include the epoch that is used to align the regional reference frame to IGS08 and the time derivatives of three translations and three rotations. The GIPSY-OASIS (V6.4) software package was used to obtain the precise point positioning (PPP) daily solutions with respect to IGS08. The frame stability of NChina16 is approximately 0.5 mm/year in both horizontal and vertical directions. This study also developed a regional model for correcting seasonal motions superimposed into the vertical component of the GPS-derived displacement time series. Long-term GPS observations (1999-2016) from five CORS in North China were used to develop the seasonal model. According to this study, the PPP daily solutions with respect to NChina16 could achieve 2-3 mm horizontal accuracy and 4-5 mm vertical accuracy after being modified by the regional model. NChina16 will be critical to study geodynamic problems in North China, such as earthquakes, faulting, subsidence, and landslides. The regional reference frame will be periodically updated every few years to mitigate degradation of the frame with time and be synchronized with the update of IGS reference frame.
Long-term monitoring of river basins: strengths and weaknesses, opportunities and threats
NASA Astrophysics Data System (ADS)
Howden, N. J. K.; Burt, T. P.
2016-12-01
In a world where equilibrium is more and more uncommon, monitoring is an essential way to discover whether undesirable change is taking place. Monitoring requires a deliberate plan of action: the regular collection and processing of information. Long-term data reveal important patterns, allowing trends, cycles, and rare events to be identified. This is particularly important for complex systems where signals may be subtle and slow to emerge. Moreover, very long data sets are essential to test hypotheses undreamt of at the time the monitoring was started. This overview includes long time series from UK river basins showing how hydrology and water quality have changed over time - and continue to change. An important conclusion is the long time frame of system recovery, well beyond the normal lifetime of individual governments or research grants. At a time of increasing hydroclimatic variability, long time series remain crucially important; in particular, continuity of observations is vital at key benchmark sites.
Suppression and Narrative Time Shifts in Adults with Right-Hemisphere Brain Damage
ERIC Educational Resources Information Center
Scharp, Victoria L.; Tompkins, Connie A.
2013-01-01
Purpose: This study examined the functioning of a central comprehension mechanism, suppression, in adults with right-hemisphere damage (RHD) while they processed narratives that cued a shift in time frame. In normal language comprehension, mental activation of concepts from a prior time frame is suppressed. The (re)activation of information…
Framing pub smoking bans: an analysis of Australian print news media coverage, March 1996–March 2003
Champion, D.; Chapman, S.
2005-01-01
Objective: To investigate framing strategies used by the Australian Hotels Association (AHA) and tobacco control groups to (respectively) resist or advocate laws providing smoke free bars. Methods: Online archives of Australian print media were searched 1996 to 2003. A thematic analysis of all statements made by AHA spokespeople and tobacco control advocates was conducted. Direct quotes or journalistic summaries of statements attributed to named people were coded into four broad themes and the slant of articles coded. Results: More than three times as many articles reported issues that were positive (n = 171) than negative (n = 48) for tobacco control objectives. The AHA emphasised negative economic issues and cultural/ideological frames about cultural identity, while tobacco control interests emphasised health concerns as well as cultural/ideological frames about threats to inequitable workplace policies. Conclusions: Smoke free bars have now been secured, suggesting that health advocates' position prevailed. The inability of the AHA to avoid the core health arguments, its wildly exaggerated economic predictions, and its frequent recourse to claiming smoke bans threatened nostalgic but outmoded vistas of Australian day to day life were decidedly backward looking and comparatively easily dismissed as being out of touch with views held by many in contemporary Australia. Health groups' emphasis on the unfairness in denying the most occupationally exposed group the same protection that all other workers enjoyed under law was powerfully and consistently argued. Australia's recent success in securing dates for the implementation of smoke free pubs is likely to have owed much to the enduring media advocacy by health groups. PMID:16020646
A geometric rationale for invariance, covariance and constitutive relations
NASA Astrophysics Data System (ADS)
Romano, Giovanni; Barretta, Raffaele; Diaco, Marina
2018-01-01
There are, in each branch of science, statements which, expressed in ambiguous or even incorrect but seemingly friendly manner, were repeated for a long time and eventually became diffusely accepted. Objectivity of physical fields and of their time rates and frame indifference of constitutive relations are among such notions. A geometric reflection on the description of frame changes as spacetime automorphisms, on induced push-pull transformations and on proper physico-mathematical definitions of material, spatial and spacetime tensor fields and of their time-derivatives along the motion, is here carried out with the aim of pointing out essential notions and of unveiling false claims. Theoretical and computational aspects of nonlinear continuum mechanics, and especially those pertaining to constitutive relations, involving material fields and their time rates, gain decisive conceptual and operative improvement from a proper geometric treatment. Outcomes of the geometric analysis are frame covariance of spacetime velocity, material stretching and material spin. A univocal and frame-covariant tool for evaluation of time rates of material fields is provided by the Lie derivative along the motion. The postulate of frame covariance of material fields is assessed to be a natural physical requirement which cannot interfere with the formulation of constitutive laws, with claims of the contrary stemming from an improper imposition of equality in place of equivalence.
Nonequilibrium dynamics of the O( N ) model on dS3 and AdS crunches
NASA Astrophysics Data System (ADS)
Kumar, S. Prem; Vaganov, Vladislav
2018-03-01
We study the nonperturbative quantum evolution of the interacting O( N ) vector model at large- N , formulated on a spatial two-sphere, with time dependent couplings which diverge at finite time. This model - the so-called "E-frame" theory, is related via a conformal transformation to the interacting O( N ) model in three dimensional global de Sitter spacetime with time independent couplings. We show that with a purely quartic, relevant deformation the quantum evolution of the E-frame model is regular even when the classical theory is rendered singular at the end of time by the diverging coupling. Time evolution drives the E-frame theory to the large- N Wilson-Fisher fixed point when the classical coupling diverges. We study the quantum evolution numerically for a variety of initial conditions and demonstrate the finiteness of the energy at the classical "end of time". With an additional (time dependent) mass deformation, quantum backreaction lowers the mass, with a putative smooth time evolution only possible in the limit of infinite quartic coupling. We discuss the relevance of these results for the resolution of crunch singularities in AdS geometries dual to E-frame theories with a classical gravity dual.
Temporal enhancement of two-dimensional color doppler echocardiography
NASA Astrophysics Data System (ADS)
Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.
2016-03-01
Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.
Contempt - Where the modularity of the mind meets the modularity of the brain?
Bzdok, Danilo; Schilbach, Leonhard
2017-01-01
"Contempt" is proposed to be a unique aspect of human nature, yet a non-natural kind. Its psychological construct is framed as a sentiment emerging from a stratification of diverse basic emotions and dispositional attitudes. Accordingly, "contempt" might transcend traditional conceptual levels in social psychology, including experience and recognition of emotion, dyadic and group dynamics, context-conditioned attitudes, time-enduring personality structure, and morality. This strikes us as a modern psychological account of a high-level, social-affective cognitive facet that joins forces with recent developments in the social neuroscience by drawing psychological conclusions from brain biology.
Achondroplasia and limb lengthening: Results in a UK cohort and review of the literature
Donaldson, James; Aftab, Syed; Bradish, Christopher
2015-01-01
Aims We aim to review the results, complications and outcomes of a single surgeon's series of lower limb lengthening in patients with achondroplasia. Methods Ten achondroplastic children underwent limb lengthening. The patients, medical records and radiographs were reviewed. Results The average age at the time of the index operation was 7.8 years. A single surgeon undertook all procedures. The average total length gain was 20.5 cm. The commonest complication was a fractured femur after removal of the frame. Conclusion Although complication rates were high (70%), none were left with any long-term sequelae and all were pleased with the results. PMID:25829758
Bassett-Gunter, Rebecca L; Martin Ginis, Kathleen A; Latimer-Cheung, Amy E
2013-12-01
The primary purpose was to examine the relative effectiveness of chronic disease and psychological health risk information combined with gain- versus loss-framed leisure time physical activity (LTPA) messages for changing perceived personal risk, LTPA response efficacy (i.e., the belief that LTPA can effectively reduce risk), and LTPA intentions. A secondary purpose was to explore the relationship between message framing and cognitive processing. Baseline assessments of perceived risk for inactivity-related disease and psychological health problems, LTPA response efficacy, and intentions were measured among 96 individuals with spinal cord injury (SCI). Participants read population-specific information about the risk for inactivity-related disease and psychological health problems following SCI, and perceived risk was reassessed. Participants were then randomized to read LTPA response efficacy messages emphasizing the benefits of LTPA (gain framed) or the risks of inactivity (loss framed). Immediately following message exposure, cognitive processing (i.e., thought listing and message recall), LTPA response efficacy, and LTPA intentions were assessed. Changes in perceived risk were observed following exposure to health risk information. Changes in LTPA response efficacy and intentions were greater following loss-framed messages targeting psychological health compared with gain-framed messages. Greater cognitive processing was observed following loss-framed messages compared with gain-framed messages. Following exposure to psychological health risk information, loss-framed messages may be more effective than gain-framed messages for eliciting cognitive processing and changing LTPA beliefs and intentions.
Reliability of frames of reference used for tibial component rotation in total knee arthroplasty.
Page, Stephen R; Deakin, Angela H; Payne, Anthony P; Picard, Frederic
2011-01-01
This study evaluated seven different frames of reference used for tibial component rotation in total knee arthroplasty (TKA) to determine which ones showed good reliability between bone specimens. An optoelectronic system based around a computer-assisted surgical navigation system was used to measure and locate 34 individual anatomical landmarks on 40 tibias. Each particular frame of reference was reconstructed from a group of data points taken from the surface of each bone. The transverse axis was used as the baseline to which the other axes were compared, and the differences in angular rotation between the other six reference frames and the transverse axis were calculated. There was high variability in the tibial rotational alignment associated with all frames of reference. Of the references widely used in current TKA procedures, the tibial tuberosity axis and the anterior condylar axis had lower standard deviations (6.1° and 7.3°, respectively) than the transmalleolar axis and the posterior condylar axis (9.3° for both). In conclusion, we found high variability in the frames of reference used for tibial rotation alignment. However, the anterior condylar axis and transverse axis may warrant further tests with the use of navigation. Combining different frames of reference such as the tibial tuberosity axis, anterior condylar axis and transverse axis may reduce the range of errors found in all of these measurements.
Persuading People to Drink Less Alcohol: The Role of Message Framing, Temporal Focus and Autonomy.
Churchill, Susan; Pavey, Louisa; Jessop, Donna; Sparks, Paul
2016-11-01
Health information can be used to try to persuade people to follow safe drinking recommendations. However, both the framing of information and the dispositional characteristics of message recipients need to be considered. An online study was conducted to examine how level of autonomy moderated the effect on drinking behaviour of gain- and loss-framed messages about the short- vs. long-term consequences of alcohol use. At Time 1, participants (N = 335) provided demographic information and completed a measure of autonomy. At Time 2, participants reported baseline alcohol use and read a gain-framed or loss-framed health message that highlighted either short- or long-term outcomes of alcohol consumption. Alcohol consumption was reported 7 days later. The results showed a significant three-way interaction between message framing (loss vs. gain), temporal focus (short-term vs. long-term) and autonomy. For low-autonomy (but not high-autonomy) individuals, the loss-framed health message was associated with lower levels of alcohol consumption than was the gain-framed message but only if the short-term outcomes were conveyed. This research provides evidence that the interaction between message framing and temporal focus may depend on a person's level of autonomy, which has implications for health promotion and the construction of effective health communication messages. We examined how autonomy moderated the effect on drinking behaviour of gain- and loss-framed messages about the short- vs. long-term consequences of alcohol use. For low-autonomy individuals, the loss-framed health message was associated with lower alcohol consumption than was the gain-framed message but only if the short-term outcomes were conveyed. © The Author 2016. Medical Council on Alcohol and Oxford University Press. All rights reserved.
Curtis, Andrew J
2008-01-01
Background An epidemic may exhibit different spatial patterns with a change in geographic scale, with each scale having different conduits and impediments to disease spread. Mapping disease at each of these scales often reveals different cluster patterns. This paper will consider this change of geographic scale in an analysis of yellow fever deaths for New Orleans in 1878. Global clustering for the whole city, will be followed by a focus on the French Quarter, then clusters of that area, and finally street-level patterns of a single cluster. The three-dimensional visualization capabilities of a GIS will be used as part of a cluster creation process that incorporates physical buildings in calculating mortality-to-mortality distance. Including nativity of the deceased will also capture cultural connection. Results Twenty-two yellow fever clusters were identified for the French Quarter. These generally mirror the results of other global cluster and density surfaces created for the entire epidemic in New Orleans. However, the addition of building-distance, and disease specific time frame between deaths reveal that disease spread contains a cultural component. Same nativity mortality clusters emerge in a similar time frame irrespective of proximity. Italian nativity mortalities were far more densely grouped than any of the other cohorts. A final examination of mortalities for one of the nativity clusters reveals that further sub-division is present, and that this pattern would only be revealed at this scale (street level) of investigation. Conclusion Disease spread in an epidemic is complex resulting from a combination of geographic distance, geographic distance with specific connection to the built environment, disease-specific time frame between deaths, impediments such as herd immunity, and social or cultural connection. This research has shown that the importance of cultural connection may be more important than simple proximity, which in turn might mean traditional quarantine measures should be re-evaluated. PMID:18721469
Design of Visco-Elastic Dampers for RC Frame for Site-Specific Earthquake
NASA Astrophysics Data System (ADS)
Kamatchi, P.; Rama Raju, K.; Ravisankar, K.; Iyer, Nagesh R.
2016-12-01
Number of Reinforced Concrete (RC) framed buildings have got damaged at Ahmedabad city, India located at about 240 km away from epicenter during January 2001, 7.6 moment magnitude (Mw) Bhuj earthquake. In the present study, two dimensional nonlinear time history dynamic analyses of a typical 13 storey frame assumed to be located at Ahmedabad is carried out with the rock level and surface level site-specific ground motion for scenario earthquake of Mw 7.6 from Bhuj. Artificial ground motions are generated using extended finite source stochastic model with seismological parameters reported in literature for 2001 Bhuj earthquake. Surface level ground motions are obtained for a typical soil profile of 100 m depth reported in literature through one dimensional equivalent linear wave propagation analyses. From the analyses, failure of frame is observed for surface level ground motions which indicates that, in addition to the in-adequacy of the cross sections and reinforcement of the RC members of the frame chosen, the rich energy content of the surface level ground motion near the fundamental time period of the frame has also contributed for the failure of frame. As a part of retrofitting measure, five Visco-elastic Dampers (VED) in chevron bracing are added to frame. For the frame considered in the present study, provision of VED is found to be effective to mitigate damage for the soil site considered.
SU-E-T-66: A Prototype for Couch Based Real-Time Dosimetry in External Beam Radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramachandran, P
Purpose: The main purpose of this study is to design a prototype for couch-based based real time dosimetry system in external beam radiotherapy Methods: A prototype of 100 ionization chambers was designed on a printed circuit board by etching the copper layer and each ionization chamber was wired to a 50 pin connector. The signals from the two 50 pin connectors collected from the ionization chambers were then transferred to a PXI module from National Instruments. The PXI module houses a current amplifier that amplifies the charge collected from the ionization chamber. The amplified signal is then sent to amore » digital multimeter module for converting the analog signal to digital signal. A software was designed in labview to read and display the signals obtained from the PXI module. A couch attachment frame was designed to house the 100 ionization chamber module. The frame was fixed underneath the treatment couch for measuring the dose during treatment. Resutls: The ionization chamber based prototype dosimetry was tested for simple radiotherapy treatment fields and found to be a useful device for measuring real time dosimetry at the treatment couch plane. This information could be used to assess the delivered dose to a patient during radiotherapy. It could be used as an invivo dosimeter during radiotherapy. Conclusion: In this study, a prototype for couch based real time dosimetry system was designed and tested. The prototype forms a basis for the development of large scale couch based real time dosimetry system that could be used to perform morning QA prior to treatment, assess real time doses delivered to patient and as a device to monitor the output of the treatment beam. Peter MacCallum Cancer Foundation.« less
Nygren, T E
1997-09-01
It is well documented that the way a static choice task is "framed" can dramatically alter choice behavior, often leading to observable preference reversals. This framing effect appears to result from perceived changes in the nature or location of a person's initial reference point, but it is not clear how framing effects might generalize to performance on dynamic decision making tasks that are characterized by high workload, time constraints, risk, or stress. A study was conducted to examine the hypothesis that framing can introduce affective components to the decision making process and can influence, either favorably (positive frame) or adversely (negative frame), the implementation and use of decision making strategies in dynamic high-workload environments. Results indicated that negative frame participants were significantly impaired in developing and employing a simple optimal decision strategy relative to a positive frame group. Discussion focuses on implications of these results for models of dynamic decision making.
A fast double shutter for CCD-based metrology
NASA Astrophysics Data System (ADS)
Geisler, R.
2017-02-01
Image based metrology such as Particle Image Velocimetry (PIV) depends on the comparison of two images of an object taken in fast succession. Cameras for these applications provide the so-called `double shutter' mode: One frame is captured with a short exposure time and in direct succession a second frame with a long exposure time can be recorded. The difference in the exposure times is typically no problem since illumination is provided by a pulsed light source such as a laser and the measurements are performed in a darkened environment to prevent ambient light from accumulating in the long second exposure time. However, measurements of self-luminous processes (e.g. plasma, combustion ...) as well as experiments in ambient light are difficult to perform and require special equipment (external shutters, highspeed image sensors, multi-sensor systems ...). Unfortunately, all these methods incorporate different drawbacks such as reduced resolution, degraded image quality, decreased light sensitivity or increased susceptibility to decalibration. In the solution presented here, off-the-shelf CCD sensors are used with a special timing to combine neighbouring pixels in a binning-like way. As a result, two frames of short exposure time can be captured in fast succession. They are stored in the on-chip vertical register in a line-interleaved pattern, read out in the common way and separated again by software. The two resultant frames are completely congruent; they expose no insensitive lines or line shifts and thus enable sub-pixel accurate measurements. A third frame can be captured at the full resolution analogue to the double shutter technique. Image based measurement techniques such as PIV can benefit from this mode when applied in bright environments. The third frame is useful e.g. for acceleration measurements or for particle tracking applications.
Hassett, Leanne; Simpson, Grahame; Cotter, Rachel; Whiting, Diane; Hodgkinson, Adeline; Martin, Diane
2015-04-01
To investigate whether the introduction of an electronic goals system followed by staff training improved the quality, rating, framing and structure of goals written by a community-based brain injury rehabilitation team. Interrupted time series design. Two interventions were introduced six months apart. The first intervention comprised the introduction of an electronic goals system. The second intervention comprised a staff goal training workshop. An audit protocol was devised to evaluate the goals. A random selection of goal statements from the 12 months prior to the interventions (Time 1 baseline) were compared with all goal statements written after the introduction of the electronic goals system (Time 2) and staff training (Time 3). All goals were de-identified for client and time-period, and randomly ordered. A total of 745 goals (Time 1 n = 242; Time 2 n = 283; Time 3 n = 220) were evaluated. Compared with baseline, the introduction of the electronic goals system alone significantly increased goal rating, framing and structure (χ(2) tests 144.7, 18.9, 48.1, respectively, p < 0.001). The addition of staff training meant that the improvement in goal quality, which was only a trend at Time 2, was statistically significant at Time 3 (χ(2) 15.0, p ≤ 001). The training also led to a further significant increase in the framing and structuring of goals over the electronic goals system (χ(2) 11.5, 12.5, respectively, p ≤ 0.001). An electronic goals system combined with staff training improved the quality, rating, framing and structure of goal statements. © The Author(s) 2014.
How to Reduce the Effect of Framing on Messages About Health
Galesic, Mirta
2010-01-01
ABSTRACT BACKGROUND Patients must be informed about risks before any treatment can be implemented. Yet serious problems in communicating these risks occur because of framing effects. OBJECTIVE To investigate the effects of different information frames when communicating health risks to people with high and low numeracy and determine whether these effects can be countered or eliminated by using different types of visual displays (i.e., icon arrays, horizontal bars, vertical bars, or pies). DESIGN Experiment on probabilistic, nationally representative US (n = 492) and German (n = 495) samples, conducted in summer 2008. OUTCOME MEASURES Participants’ risk perceptions of the medical risk expressed in positive (i.e., chances of surviving after surgery) and negative (i.e., chances of dying after surgery) terms. KEY RESULTS Although low‐numeracy people are more susceptible to framing than those with high numeracy, use of visual aids is an effective method to eliminate its effects. However, not all visual aids were equally effective: pie charts and vertical and horizontal bars almost completely removed the effect of framing. Icon arrays, however, led to a smaller decrease in the framing effect. CONCLUSIONS Difficulties with understanding numerical information often do not reside in the mind, but in the representation of the problem. PMID:20737295
Time evolution of nanosecond runaway discharges in air and helium at atmospheric pressure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yatom, S.; Vekselman, V.; Krasik, Ya. E.
2012-12-15
Time- and space-resolved fast framing photography was employed to study the discharge initiated by runaway electrons in air and He gas at atmospheric pressure. Whereas in the both cases, the discharge occurs in a nanosecond time scale and its front propagates with a similar velocity along the cathode-anode gap, the later stages of the discharge differ significantly. In air, the main discharge channels develop and remain in the locations with the strongest field enhancement. In He gas, the first, diode 'gap bridging' stage, is similar to that obtained in air; however, the development of the discharge that follows is dictatedmore » by an explosive electron emission from micro-protrusions on the edge of the cathode. These results allow us to draw conclusions regarding the different conductivity of the plasma produced in He and air discharges.« less
19 CFR 192.14 - Electronic information for outward cargo required in advance of departure.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Specifically, to effect the advance electronic transmission of the required cargo information to CBP, the USPPI... two hours prior to the arrival of the train at the border. (2) Applicability of time frames. The time... compliance with the time frames provided in paragraph (b)(1) of this section. Requirements placed on exports...
High-speed cinematography of muscle contraction.
HAUPT, R E; WALL, D M
1962-07-13
Motion pictures of the "twitch" of an excised frog gastrocnemius muscle taken at rates of 6000 frames per second provide a means of very accurately timing the phases. The extreme "slow motion" reveals surface phenomena not observable by other techniques. Evidence of "active relaxation" is suggested by results of frame-by-frame analysis.
Mayhorn, Christopher B; Fisk, Arthur D; Whittle, Justin D
2002-01-01
Decision making in uncertain environments is a daily challenge faced by adults of all ages. Framing decision options as either gains or losses is a common method of altering decision-making behavior. In the experiment reported here, benchmark decision-making data collected in the 1970s by Tversky and Kahneman (1981, 1988) were compared with data collected from current samples of young and older adults to determine whether behavior was consistent across time. Although differences did emerge between the benchmark and the present samples, the effect of framing on decision behavior was relatively stable. The present findings suggest that adults of all ages are susceptible to framing effects. Results also indicated that apparent age differences might be better explained by an analysis of cohort and time-of-testing effects. Actual or potential applications of this research include an understanding of how framing might influence the decision-making behavior of people of all ages in a number of applied contexts, such as product warning interactions and medical decision scenarios.
Rapid convergence of optimal control in NMR using numerically-constructed toggling frames
NASA Astrophysics Data System (ADS)
Coote, Paul; Anklin, Clemens; Massefski, Walter; Wagner, Gerhard; Arthanari, Haribabu
2017-08-01
We present a numerical method for rapidly solving the Bloch equation for an arbitrary time-varying spin-1/2 Hamiltonian. The method relies on fast, vectorized computations such as summation and quaternion multiplication, rather than slow computations such as matrix exponentiation. A toggling frame is constructed in which the Hamiltonian is time-invariant, and therefore has a simple analytical solution. The key insight is that constructing this frame is faster than solving the system dynamics in the original frame. Rapidly solving the Bloch equations for an arbitrary Hamiltonian is particularly useful in the context of NMR optimal control. Optimal control theory can be used to design pulse shapes for a range of tasks in NMR spectroscopy. However, it requires multiple simulations of the Bloch equations at each stage of the algorithm, and for each relevant set of parameters (e.g. chemical shift frequencies). This is typically time consuming. We demonstrate that by working in an appropriate toggling frame, optimal control pulses can be generated much faster. We present a new alternative to the well-known GRAPE algorithm to continuously update the toggling-frame as the optimal pulse is generated, and demonstrate that this approach is extremely fast. The use and benefit of rapid optimal pulse generation is demonstrated for 19F fragment screening experiments.
Frame Rate Considerations for Real-Time Abdominal Acoustic Radiation Force Impulse Imaging
Fahey, Brian J.; Palmeri, Mark L.; Trahey, Gregg E.
2008-01-01
With the advent of real-time Acoustic Radiation Force Impulse (ARFI) imaging, elevated frame rates are both desirable and relevant from a clinical perspective. However, fundamental limitations on frame rates are imposed by thermal safety concerns related to incident radiation force pulses. Abdominal ARFI imaging utilizes a curvilinear scanning geometry that results in markedly different tissue heating patterns than those previously studied for linear arrays or mechanically-translated concave transducers. Finite Element Method (FEM) models were used to simulate these tissue heating patterns and to analyze the impact of tissue heating on frame rates available for abdominal ARFI imaging. A perfusion model was implemented to account for cooling effects due to blood flow and frame rate limitations were evaluated in the presence of normal, reduced and negligible tissue perfusions. Conventional ARFI acquisition techniques were also compared to ARFI imaging with parallel receive tracking in terms of thermal efficiency. Additionally, thermocouple measurements of transducer face temperature increases were acquired to assess the frame rate limitations imposed by cumulative heating of the imaging array. Frame rates sufficient for many abdominal imaging applications were found to be safely achievable utilizing available ARFI imaging techniques. PMID:17521042
Multiple-frame IR photo-recorder KIT-3M
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roos, E; Wilkins, P; Nebeker, N
2006-05-15
This paper reports the experimental results of a high-speed multi-frame infrared camera which has been developed in Sarov at VNIIEF. Earlier [1] we discussed the possibility of creation of the multi-frame infrared radiation photo-recorder with framing frequency about 1 MHz. The basis of the photo-recorder is a semiconductor ionization camera [2, 3], which converts IR radiation of spectral range 1-10 micrometers into a visible image. Several sequential thermal images are registered by using the IR converter in conjunction with a multi-frame electron-optical camera. In the present report we discuss the performance characteristics of a prototype commercial 9-frame high-speed IR photo-recorder.more » The image converter records infrared images of thermal fields corresponding to temperatures ranging from 300 C to 2000 C with an exposure time of 1-20 {micro}s at a frame frequency up to 500 KHz. The IR-photo-recorder camera is useful for recording the time evolution of thermal fields in fast processes such as gas dynamics, ballistics, pulsed welding, thermal processing, automotive industry, aircraft construction, in pulsed-power electric experiments, and for the measurement of spatial mode characteristics of IR-laser radiation.« less
Temporal compressive imaging for video
NASA Astrophysics Data System (ADS)
Zhou, Qun; Zhang, Linxia; Ke, Jun
2018-01-01
In many situations, imagers are required to have higher imaging speed, such as gunpowder blasting analysis and observing high-speed biology phenomena. However, measuring high-speed video is a challenge to camera design, especially, in infrared spectrum. In this paper, we reconstruct a high-frame-rate video from compressive video measurements using temporal compressive imaging (TCI) with a temporal compression ratio T=8. This means that, 8 unique high-speed temporal frames will be obtained from a single compressive frame using a reconstruction algorithm. Equivalently, the video frame rates is increased by 8 times. Two methods, two-step iterative shrinkage/threshold (TwIST) algorithm and the Gaussian mixture model (GMM) method, are used for reconstruction. To reduce reconstruction time and memory usage, each frame of size 256×256 is divided into patches of size 8×8. The influence of different coded mask to reconstruction is discussed. The reconstruction qualities using TwIST and GMM are also compared.
Differences in Simulated Doctor and Patient Medical Decision Making: A Construal Level Perspective
Zhang, Yan; Liu, Quanhui; Miao, Danmin; Xiao, Wei
2013-01-01
Background Patients are often confronted with diverse medical decisions. Often lacking relevant medical knowledge, patients fail to independently make medical decisions and instead generally rely on the advice of doctors. Objective This study investigated the characteristics of and differences in doctor–patient medical decision making on the basis of construal level theory. Methods A total of 420 undergraduates majoring in clinical medicine were randomly assigned to six groups. Their decisions to opt for radiotherapy and surgery were investigated, with the choices described in a positive/neutral/negative frame × decision making for self/others. Results Compared with participants giving medical advice to patients, participants deciding for themselves were more likely to select radiotherapy (F1, 404 = 13.92, p = 011). Participants from positive or neutral frames exhibited a higher tendency to choose surgery than did those from negative frames (F2, 404 = 22.53, p<.001). The effect of framing on independent decision making was nonsignificant (F2, 404 = 1.07, p = 35); however the effect of framing on the provision of advice to patients was significant (F2, 404 = 12.95, p<.001). The effect of construal level was significant in the positive frame (F1, 404 = 8.06, p = 005) and marginally significant in the neutral frame (F2, 404 = 3.31, p = 07) but nonsignificant in the negative frame (F2, 404 = .29, p = 59). Conclusion Both social distance and framing depiction significantly affected medical decision making and exhibited a significant interaction. Differences in medical decision making between doctors and patients need further investigation. PMID:24244445
Framing of Uncertainty in Scientific Publications: Towards Recommendations for Decision Support
NASA Astrophysics Data System (ADS)
Guillaume, J. H. A.; Helgeson, C.; Elsawah, S.; Jakeman, A. J.; Kummu, M.
2016-12-01
Uncertainty is recognised as an essential issue in environmental decision making and decision support. As modellers, we notably use a variety of tools and techniques within an analysis, for example related to uncertainty quantification and model validation. We also address uncertainty by how we present results. For example, experienced modellers are careful to distinguish robust conclusions from those that need further work, and the precision of quantitative results is tailored to their accuracy. In doing so, the modeller frames how uncertainty should be interpreted by their audience. This is an area which extends beyond modelling to fields such as philosophy of science, semantics, discourse analysis, intercultural communication and rhetoric. We propose that framing of uncertainty deserves greater attention in the context of decision support, and that there are opportunities in this area for fundamental research, synthesis and knowledge transfer, development of teaching curricula, and significant advances in managing uncertainty in decision making. This presentation reports preliminary results of a study of framing practices. Specifically, we analyse the framing of uncertainty that is visible in the abstracts from a corpus of scientific articles. We do this through textual analysis of the content and structure of those abstracts. Each finding that appears in an abstract is classified according to the uncertainty framing approach used, using a classification scheme that was iteratively revised based on reflection and comparison amongst three coders. This analysis indicates how frequently the different framing approaches are used, and provides initial insights into relationships between frames, how the frames relate to interpretation of uncertainty, and how rhetorical devices are used by modellers to communicate uncertainty in their work. We propose initial hypotheses for how the resulting insights might influence decision support, and help advance decision making to better address uncertainty.
Merdasi, Fatemeh; Araban, Marzieh; Saki, Malehi Amal
2017-01-01
Introduction Exclusive breastfeeding for 6 months and continuing it for 2 years, along with complementary feeding, are the primary objectives of public health plans and nutrition around the world. Self-efficacy is a theoretical framework that could be a strong predictive for breastfeeding. This study aimed to determine the effect of message-framing on self-efficacy of breastfeeding in nulliparous women in Shushtar. Methods This quasi-experimental study was conducted in 2015 on 210 nulliparous women in Shushtar (Iran). The participants were randomly allocated into intervention and control groups. The study tool was the short form of breastfeeding self-efficacy scale that was completed on arrival of the study (days 3–5), at the end of week four and at the end of week eight. Data were analyzed by SPSS 19, using Chi-square, ANOVA, and repeated measurements. Results Mean age of participants was 24.52 years old with standard deviation of 95.4. Mean score of breastfeeding self-efficacy in gain-framed group at days 3–5, week four and week eight was 47.94, 57.43 and 52.8 respectively; in loss-framed group it was 47.76, 56.11 and 52.64 respectively; and in control group it was 45.16, 48.68 and 45.31 respectively. No significant difference was observed between the score of average self-efficacy of days 3–5 and week eight in control group (p=0.93). However, in gain-framed group (p=0.001) and loss-framed group (p=0.004), a significant difference was observed. Conclusion Results of this study showed that message-framing promotes breastfeeding self-efficacy in nulliparous women and in this regard, there is no difference between gain-framed and loss-framed messages. PMID:28243406
Brick, Cameron; McCully, Scout N.; Updegraff, John A.; Ehret, Phillip J.; Areguin, Maira A.; Sherman, David K.
2015-01-01
Background Health messages are more effective when framed to be congruent with recipient characteristics, and health practitioners can strategically decide on message features to promote adherence to recommended behaviors. We present exposure to United States (U.S.) culture as a moderator of the impact of gain- vs. loss-frame messages. Since U.S. culture emphasizes individualism and approach orientation, greater cultural exposure was expected to predict improved patient choices and memory for gain-framed messages, whereas individuals with less exposure to U.S. culture would show these advantages for loss-framed messages. Methods 223 participants viewed a written oral health message in one of three randomized conditions: gain-frame, loss-frame, or no-message control, and were given ten flosses. Cultural exposure was measured with the proportions of life spent and parents born in the U.S. At baseline and one week later, participants completed recall tests and reported recent flossing behavior. Results Message frame and cultural exposure interacted to predict improved patient decisions (increased flossing) and memory maintenance for the health message over one week. E.g., those with low cultural exposure who saw a loss-frame message flossed more. Incongruent messages led to the same flossing rates as no message. Memory retention did not explain the effect of message congruency on flossing. Limitations Flossing behavior was self-reported. Cultural exposure may only have practical application in either highly individualistic or collectivistic countries. Conclusions In healthcare settings where patients are urged to follow a behavior, asking basic demographic questions could allow medical practitioners to intentionally communicate in terms of gains or losses to improve patient decision making and treatment adherence. PMID:25654986
Kepler Fine Guidance Sensor Data
NASA Technical Reports Server (NTRS)
Van Cleve, Jeffrey; Campbell, Jennifer Roseanna
2017-01-01
The Kepler and K2 missions collected Fine Guidance Sensor (FGS) data in addition to the science data, as discussed in the Kepler Instrument Handbook (KIH, Van Cleve and Caldwell 2016). The FGS CCDs are frame transfer devices (KIH Table 7) located in the corners of the Kepler focal plane (KIH Figure 24), which are read out 10 times every second. The FGS data are being made available to the user community for scientific analysis as flux and centroid time series, along with a limited number of FGS full frame images which may be useful for constructing a World Coordinate System (WCS) or otherwise putting the time series data in context. This document will describe the data content and file format, and give example MATLAB scripts to read the time series. There are three file types delivered as the FGS data.1. Flux and Centroid (FLC) data: time series of star signal and centroid data. 2. Ancillary FGS Reference (AFR) data: catalog of information about the observed stars in the FLC data. 3. FGS Full-Frame Image (FGI) data: full-frame image snapshots of the FGS CCDs.
The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, Stephen, E-mail: syip@lroc.harvard.edu; Rottmann, Joerg; Berbeco, Ross
2014-06-15
Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained bymore » continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.« less
NASA Astrophysics Data System (ADS)
Kopeikin, Sergei; Xie, Yi
2010-11-01
We introduce the Jacobi coordinates adopted to the advanced theoretical analysis of the relativistic Celestial Mechanics of the Earth-Moon system. Theoretical derivation utilizes the relativistic resolutions on reference frames adopted by the International Astronomical Union (IAU) in 2000. The resolutions assume that the Solar System is isolated and space-time is asymptotically flat at infinity and the primary reference frame covers the entire space-time, has its origin at the Solar System barycenter (SSB) with spatial axes stretching up to infinity. The SSB frame is not rotating with respect to a set of distant quasars that are assumed to be at rest on the sky forming the International Celestial Reference Frame (ICRF). The second reference frame has its origin at the Earth-Moon barycenter (EMB). The EMB frame is locally inertial and is not rotating dynamically in the sense that equation of motion of a test particle moving with respect to the EMB frame, does not contain the Coriolis and centripetal forces. Two other local frames—geocentric and selenocentric—have their origins at the center of mass of Earth and Moon respectively and do not rotate dynamically. Each local frame is subject to the geodetic precession both with respect to other local frames and with respect to the ICRF because of their relative motion with respect to each other. Theoretical advantage of the dynamically non-rotating local frames is in a more simple mathematical description of the metric tensor and relative equations of motion of the Moon with respect to Earth. Each local frame can be converted to kinematically non-rotating one after alignment with the axes of ICRF by applying the matrix of the relativistic precession as recommended by the IAU resolutions. The set of one global and three local frames is introduced in order to decouple physical effects of gravity from the gauge-dependent effects in the equations of relative motion of the Moon with respect to Earth.
Using Temporal Fill Factor to Reduce Frame Reconstruction Rates
NASA Technical Reports Server (NTRS)
Larimer, James; Balram, Nikhil; Gille, Jennifer; Luszcz, Jeffery
1997-01-01
The newer active matrix display technologies such as TFT-LCD, DMD, PDP maintain their pixel values through the entire frame time, presenting a 100% temporal fill factor, in contrast to the duty cycle produced by the phosphor impulse response of the CRT. This sample-and-hold characteristic can be exploited to lower the displayed frame rate without affecting visual quality. The lower frame rate results in significantly lower transmission bandwidth, power, and cost.
Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel; ...
2016-04-19
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qingteng; Dufresne, Eric M.; Grybos, Pawel
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
Population control of self-replicating systems
NASA Technical Reports Server (NTRS)
Mccord, R. L.
1982-01-01
The literature concerning fibonacci sequence and the mathematics of self replication are reviewed. One option allows each primary to generate n-replicas, one in each sequential time frame after its own generation with no restrictions on the number of ancestors per replica. The state vector of the replicas in an efficient manner is determined. Option-B has a fixed number of replicas per primary and no restrictions on the number of ancestors for a replica. Any element fij represents the number of elements of type-j in time frame k+1 generated from type-i in time frame k. Option-D is a diagonal matrix whose eigenvalues are precisely those of f.
Zhang, Qingteng; Dufresne, Eric M; Grybos, Pawel; Kmon, Piotr; Maj, Piotr; Narayanan, Suresh; Deptuch, Grzegorz W; Szczygiel, Robert; Sandy, Alec
2016-05-01
Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. The potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.
Human action recognition based on kinematic similarity in real time
Chen, Longting; Luo, Ailing; Zhang, Sicong
2017-01-01
Human action recognition using 3D pose data has gained a growing interest in the field of computer robotic interfaces and pattern recognition since the availability of hardware to capture human pose. In this paper, we propose a fast, simple, and powerful method of human action recognition based on human kinematic similarity. The key to this method is that the action descriptor consists of joints position, angular velocity and angular acceleration, which can meet the different individual sizes and eliminate the complex normalization. The angular parameters of joints within a short sliding time window (approximately 5 frames) around the current frame are used to express each pose frame of human action sequence. Moreover, three modified KNN (k-nearest-neighbors algorithm) classifiers are employed in our method: one for achieving the confidence of every frame in the training step, one for estimating the frame label of each descriptor, and one for classifying actions. Additional estimating of the frame’s time label makes it possible to address single input frames. This approach can be used on difficult, unsegmented sequences. The proposed method is efficient and can be run in real time. The research shows that many public datasets are irregularly segmented, and a simple method is provided to regularize the datasets. The approach is tested on some challenging datasets such as MSR-Action3D, MSRDailyActivity3D, and UTD-MHAD. The results indicate our method achieves a higher accuracy. PMID:29073131
Bi, Sheng; Zeng, Xiao; Tang, Xin; Qin, Shujia; Lai, King Wai Chiu
2016-01-01
Compressive sensing (CS) theory has opened up new paths for the development of signal processing applications. Based on this theory, a novel single pixel camera architecture has been introduced to overcome the current limitations and challenges of traditional focal plane arrays. However, video quality based on this method is limited by existing acquisition and recovery methods, and the method also suffers from being time-consuming. In this paper, a multi-frame motion estimation algorithm is proposed in CS video to enhance the video quality. The proposed algorithm uses multiple frames to implement motion estimation. Experimental results show that using multi-frame motion estimation can improve the quality of recovered videos. To further reduce the motion estimation time, a block match algorithm is used to process motion estimation. Experiments demonstrate that using the block match algorithm can reduce motion estimation time by 30%. PMID:26950127
NASA Astrophysics Data System (ADS)
Deng, Liansheng; Jiang, Weiping; Li, Zhao; Chen, Hua; Wang, Kaihua; Ma, Yifang
2017-02-01
Higher-order ionospheric (HOI) delays are one of the principal technique-specific error sources in precise global positioning system analysis and have been proposed to become a standard part of precise GPS data processing. In this research, we apply HOI delay corrections to the Crustal Movement Observation Network of China's (CMONOC) data processing (from January 2000 to December 2013) and furnish quantitative results for the effects of HOI on CMONOC coordinate time series. The results for both a regional reference frame and global reference frame are analyzed and compared to clarify the HOI effects on the CMONOC network. We find that HOI corrections can effectively reduce the semi-annual signals in the northern and vertical components. For sites with lower semi-annual amplitudes, the average decrease in magnitude can reach 30 and 10 % for the northern and vertical components, respectively. The noise amplitudes with HOI corrections and those without HOI corrections are not significantly different. Generally, the HOI effects on CMONOC networks in a global reference frame are less obvious than the results in the regional reference frame, probably because the HOI-induced errors are smaller in comparison to the higher noise levels seen when using a global reference frame. Furthermore, we investigate the combined contributions of environmental loading and HOI effects on the CMONOC stations. The largest loading effects on the vertical displacement are found in the mid- to high-latitude areas. The weighted root mean square differences between the corrected and original weekly GPS height time series of the loading model indicate that the mass loading adequately reduced the scatter on the CMONOC height time series, whereas the results in the global reference frame showed better agreements between the GPS coordinate time series and the environmental loading. When combining the effects of environmental loading and HOI corrections, the results with the HOI corrections reduced the scatter on the observed GPS height coordinates better than the height when estimated without HOI corrections, and the combined solutions in the regional reference frame indicate more preferred improvements. Therefore, regional reference frames are recommended to investigate the HOI effects on regional networks.
NASA Technical Reports Server (NTRS)
Truong, L. V.
1994-01-01
Computer graphics are often applied for better understanding and interpretation of data under observation. These graphics become more complicated when animation is required during "run-time", as found in many typical modern artificial intelligence and expert systems. Living Color Frame Maker is a solution to many of these real-time graphics problems. Living Color Frame Maker (LCFM) is a graphics generation and management tool for IBM or IBM compatible personal computers. To eliminate graphics programming, the graphic designer can use LCFM to generate computer graphics frames. The graphical frames are then saved as text files, in a readable and disclosed format, which can be easily accessed and manipulated by user programs for a wide range of "real-time" visual information applications. For example, LCFM can be implemented in a frame-based expert system for visual aids in management of systems. For monitoring, diagnosis, and/or controlling purposes, circuit or systems diagrams can be brought to "life" by using designated video colors and intensities to symbolize the status of hardware components (via real-time feedback from sensors). Thus status of the system itself can be displayed. The Living Color Frame Maker is user friendly with graphical interfaces, and provides on-line help instructions. All options are executed using mouse commands and are displayed on a single menu for fast and easy operation. LCFM is written in C++ using the Borland C++ 2.0 compiler for IBM PC series computers and compatible computers running MS-DOS. The program requires a mouse and an EGA/VGA display. A minimum of 77K of RAM is also required for execution. The documentation is provided in electronic form on the distribution medium in WordPerfect format. A sample MS-DOS executable is provided on the distribution medium. The standard distribution medium for this program is one 5.25 inch 360K MS-DOS format diskette. The contents of the diskette are compressed using the PKWARE archiving tools. The utility to unarchive the files, PKUNZIP.EXE, is included. The Living Color Frame Maker tool was developed in 1992.
A Kalman filter approach for the determination of celestial reference frames
NASA Astrophysics Data System (ADS)
Soja, Benedikt; Gross, Richard; Jacobs, Christopher; Chin, Toshio; Karbon, Maria; Nilsson, Tobias; Heinkelmann, Robert; Schuh, Harald
2017-04-01
The coordinate model of radio sources in International Celestial Reference Frames (ICRF), such as the ICRF2, has traditionally been a constant offset. While sufficient for a large part of radio sources considering current accuracy requirements, several sources exhibit significant temporal coordinate variations. In particular, the group of the so-called special handling sources is characterized by large fluctuations in the source positions. For these sources and for several from the "others" category of radio sources, a coordinate model that goes beyond a constant offset would be beneficial. However, due to the sheer amount of radio sources in catalogs like the ICRF2, and even more so with the upcoming ICRF3, it is difficult to find the most appropriate coordinate model for every single radio source. For this reason, we have developed a time series approach to the determination of celestial reference frames (CRF). We feed the radio source coordinates derived from single very long baseline interferometry (VLBI) sessions sequentially into a Kalman filter and smoother, retaining their full covariances. The estimation of the source coordinates is carried out with a temporal resolution identical to the input data, i.e. usually 1-4 days. The coordinates are assumed to behave like random walk processes, an assumption which has already successfully been made for the determination of terrestrial reference frames such as the JTRF2014. To be able to apply the most suitable process noise value for every single radio source, their statistical properties are analyzed by computing their Allan standard deviations (ADEV). Additional to the determination of process noise values, the ADEV allows drawing conclusions whether the variations in certain radio source positions significantly deviate from random walk processes. Our investigations also deal with other means of source characterization, such as the structure index, in order to derive a suitable process noise model. The Kalman filter CRFs resulting from the different approaches are compared among each other, to the original radio source position time series, as well as to a traditional CRF solution, in which the constant source positions are estimated in a global least squares adjustment.
2010-01-01
Background Experts recommend formulating a structured research question to guide the research design. However, the basis for this recommendation has not been formally evaluated. The aim of this study was to examine if a structured research question using the PICOT (Population, Intervention, Comparator, Outcome, Time-frame) format is associated with a better reporting quality of randomized controlled trials (RCTs). Methods We evaluated 89 RCTs reports published in three endocrinology journals in 2005 and 2006, the quality of reporting of which was assessed in a previous study. We examined whether the reports stated each of the five elements of a structured research question: population, intervention, comparator, outcome and time-frame. A PICOT score was created with a possible score between 0 and 5. Outcomes were: 1) a 14-point overall reporting quality score (OQS) based on the Consolidated Standards for Reporting Trials; and 2) a 3-point key score (KS), based on allocation concealment, blinding and use of intention-to-treat analysis. We conducted multivariable regression analyses using generalized estimating equations to determine if a higher PICOT score or the use of a structured research question were independently associated with a better reporting quality. Journal of publication, funding source and sample size were identified as factors associated with OQS in our previous report on this dataset, and therefore included in the model. Results A higher PICOT score was independently associated with OQS (incidence rate ratio (IRR) = 1.021, 95% CI: 1.012 to 1.029) and KS (IRR = 1.142, 95% CI: 1.079 to 1.210). A structured research question was present in 33.7% of the reports and it was associated with a better OQS (IRR = 1.095, 95% CI 1.059-1.132) and KS (IRR = 1.530, 95% CI 1.311-1.786). Conclusions Better framing of the research question using the PICOT format is independently associated with better overall reporting quality - although the effect is small - and better reporting of key methodologies. PMID:20137069
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vijayan, S; Rana, V; Nagesh, S Setlur
Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detectormore » was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.« less
Describing Treatment Effects to Patients
Moxey, Annette; O'Connell, Dianne; McGettigan, Patricia; Henry, David
2003-01-01
OBJECTIVE To examine the impact of different presentations of equivalent information (framing) on treatment decisions faced by patients. DESIGN A systematic review of the published literature was conducted. English language publications allocating participants to different frames were retrieved using electronic and bibliographic searches. Two reviewers examined each article for inclusion, and assessed methodological quality. Study characteristics were tabulated and where possible, relative risks (RR; 95% confidence intervals) were calculated to estimate intervention effects. MEASUREMENTS AND MAIN RESULTS Thirty-seven articles, yielding 40 experimental studies, were included. Studies examined treatment (N = 24), immunization (N = 5), or health behavior scenarios (N = 11). Overall, active treatments were preferred when outcomes were described in terms of relative rather than absolute risk reductions or number needed to treat. Surgery was preferred to other treatments when treatment efficacy was presented in a positive frame (survival) rather than a negative frame (mortality) (relative risk [RR] = 1.51, 95% confidence interval [CI], 1.39 to 1.64). Framing effects were less obvious for immunization and health behavior scenarios. Those with little interest in the behavior at baseline were influenced by framing, particularly when information was presented as gains. In studies judged to be of good methodological quality and/or examining actual decisions, the framing effect, although still evident, was less convincing compared to the results of all included studies. CONCLUSIONS Framing effects varied with the type of scenario, responder characteristics, scenario manipulations, and study quality. When describing treatment effects to patients, expressing the information in more than one way may present a balanced view to patients and enable them to make informed decisions. PMID:14687282
Gugsa, Frey; Karmarkar, Ellora; Cheyne, Andrew; Yamey, Gavin
2016-01-01
Objective To examine newspaper coverage of maternal health in three countries that have made varying progress towards Millennium Development Goal 5 (MDG 5): Bangladesh (on track), Rwanda (making progress, but not on track) and South Africa (no progress). Design We analysed each country's leading national English-language newspaper: Bangladesh's The Daily Star, Rwanda's The New Times/The Sunday Times, and South Africa's Sunday Times/The Times. We quantified the number of maternal health articles published from 1 January 2008 to 31 March 2013. We conducted a content analysis of subset of 190 articles published from 1 October 2010 to 31 March 2013. Results Bangladesh's The Daily Star published 579 articles related to maternal health from 1 January 2008 to 31 March 2013, compared to 342 in Rwanda's The New Times/The Sunday Times and 253 in South Africa's Sunday Times/The Times over the same time period. The Daily Star had the highest proportion of stories advocating for or raising awareness of maternal health. Most maternal health articles in The Daily Star (83%) and The New Times/The Sunday Times (69%) used a ‘human-rights’ or ‘policy-based’ frame compared to 41% of articles from Sunday Times/The Times. Conclusions In the three countries included in this study, which are on different trajectories towards MDG 5, there were differences in the frequency, tone and content of their newspaper coverage of maternal health. However, no causal conclusions can be drawn about this association between progress on MDG 5 and the amount and type of media coverage of maternal health. PMID:26769780
Controlling the Display of Capsule Endoscopy Video for Diagnostic Assistance
NASA Astrophysics Data System (ADS)
Vu, Hai; Echigo, Tomio; Sagawa, Ryusuke; Yagi, Keiko; Shiba, Masatsugu; Higuchi, Kazuhide; Arakawa, Tetsuo; Yagi, Yasushi
Interpretations by physicians of capsule endoscopy image sequences captured over periods of 7-8 hours usually require 45 to 120 minutes of extreme concentration. This paper describes a novel method to reduce diagnostic time by automatically controlling the display frame rate. Unlike existing techniques, this method displays original images with no skipping of frames. The sequence can be played at a high frame rate in stable regions to save time. Then, in regions with rough changes, the speed is decreased to more conveniently ascertain suspicious findings. To realize such a system, cue information about the disparity of consecutive frames, including color similarity and motion displacements is extracted. A decision tree utilizes these features to classify the states of the image acquisitions. For each classified state, the delay time between frames is calculated by parametric functions. A scheme selecting the optimal parameters set determined from assessments by physicians is deployed. Experiments involved clinical evaluations to investigate the effectiveness of this method compared to a standard-view using an existing system. Results from logged action based analysis show that compared with an existing system the proposed method reduced diagnostic time to around 32.5 ± minutes per full sequence while the number of abnormalities found was similar. As well, physicians needed less effort because of the systems efficient operability. The results of the evaluations should convince physicians that they can safely use this method and obtain reduced diagnostic times.
NASA Astrophysics Data System (ADS)
Hong, Inki; Cho, Sanghee; Michel, Christian J.; Casey, Michael E.; Schaefferkoetter, Joshua D.
2014-09-01
A new data handling method is presented for improving the image noise distribution and reducing bias when reconstructing very short frames from low count dynamic PET acquisition. The new method termed ‘Complementary Frame Reconstruction’ (CFR) involves the indirect formation of a count-limited emission image in a short frame through subtraction of two frames with longer acquisition time, where the short time frame data is excluded from the second long frame data before the reconstruction. This approach can be regarded as an alternative to the AML algorithm recently proposed by Nuyts et al, as a method to reduce the bias for the maximum likelihood expectation maximization (MLEM) reconstruction of count limited data. CFR uses long scan emission data to stabilize the reconstruction and avoids modification of algorithms such as MLEM. The subtraction between two long frame images, naturally allows negative voxel values and significantly reduces bias introduced in the final image. Simulations based on phantom and clinical data were used to evaluate the accuracy of the reconstructed images to represent the true activity distribution. Applicability to determine the arterial input function in human and small animal studies is also explored. In situations with limited count rate, e.g. pediatric applications, gated abdominal, cardiac studies, etc., or when using limited doses of short-lived isotopes such as 15O-water, the proposed method will likely be preferred over independent frame reconstruction to address bias and noise issues.
Slow speed—fast motion: time-lapse recordings in physics education
NASA Astrophysics Data System (ADS)
Vollmer, Michael; Möllmann, Klaus-Peter
2018-05-01
Video analysis with a 30 Hz frame rate is the standard tool in physics education. The development of affordable high-speed-cameras has extended the capabilities of the tool for much smaller time scales to the 1 ms range, using frame rates of typically up to 1000 frames s-1, allowing us to study transient physics phenomena happening too fast for the naked eye. Here we want to extend the range of phenomena which may be studied by video analysis in the opposite direction by focusing on much longer time scales ranging from minutes, hours to many days or even months. We discuss this time-lapse method, needed equipment and give a few hints of how to produce respective recordings for two specific experiments.
Validity and reproducibility of self-reported working hours among Japanese male employees.
Imai, Teppei; Kuwahara, Keisuke; Miyamoto, Toshiaki; Okazaki, Hiroko; Nishihara, Akiko; Kabe, Isamu; Mizoue, Tetsuya; Dohi, Seitaro
2016-07-22
Working long hours is a potential health hazard. Although self-reporting of working hours in various time frames has been used in epidemiologic studies, its validity is unclear. The objective of this study was to examine the validity and reproducibility of self-reported working hours among Japanese male employees. The participants were 164 male employees of four large-scale companies in Japan. For validity, the Spearman correlation between self-reported working hours in the second survey and the working hours recorded by the company was calculated for the following four time frames: daily working hours, monthly overtime working hours in the last month, average overtime working hours in the last 3 months, and the frequency of long working months (≥45 h/month) within the last 12 months. For reproducibility, the intraclass correlation between the first (September 2013) and second surveys (December 2013) was calculated for each of the four time frames. The Spearman correlations between self-reported working hours and those based on company records were 0.74, 0.81, 0.85, and 0.89 for daily, monthly, 3-monthly, and yearly time periods, respectively. The intraclass correlations for self-reported working hours between the two questionnaire surveys were 0.63, 0.66, 0.73, and 0.87 for the respective time frames. The results of the present study among Japanese male employees suggest that the validity of self-reported working hours is high for all four time frames, whereas the reproducibility is moderate to high.
Research opportunities in space motion sickness, phase 2
NASA Technical Reports Server (NTRS)
Talbot, J. M.
1983-01-01
Space and motion sickness, the current and projected NASA research program, and the conclusions and suggestions of the ad hoc Working Group are summarized. The frame of reference for the report is ground-based research.
Starr, Vanessa; Olivecrona, H; Noz, M E; Maguire, G Q; Zeleznik, M P; Jannsson, Karl-åke
2009-01-01
In this study we explore the possibility of accurately and cost-effectively monitoring tibial deformation induced by Taylor Spatial Frames (TSFs), using time-separated computed tomography (CT) scans and a volume fusion technique to determine tibial rotation and translation. Serial CT examinations (designated CT-A and CT-B, separated by a time interval of several months) of two patients were investigated using a previously described and validated volume fusion technique, in which user-defined landmarks drive the 3D registration of the two CT volumes. Both patients had undergone dual osteotomies to correct for tibial length and rotational deformity. For each registration, 10 or more landmarks were selected, and the quality of the fused volume was assessed both quantitatively and via 2D and 3D visualization tools. First, the proximal frame segment and tibia in CT-A and CT-B were brought into alignment (registered) by selecting landmarks on the frame and/or tibia. In the resulting "fused" volume, the proximal frame segment and tibia from CT-A and CT-B were aligned, while the distal frame segment and tibia from CT-A and CT-B were likely not aligned as a result of tibial deformation or frame adjustment having occurred between the CT scans. Using the proximal fused volume, the distal frame segment and tibia were then registered by selecting landmarks on the frame and/or tibia. The difference between the centroids of the final distal landmarks was used to evaluate the lengthening of the tibia, and the Euler angles from the registration were used to evaluate the rotation. Both the frame and bone could be effectively registered (based on visual interpretation). Movement between the proximal frame and proximal bone could be visualized in both cases. The spatial effect on the tibia could be both visually assessed and measured: 34 mm, 10 degrees in one case; 5 mm, 1 degrees in the other. This retrospective analysis of spatial correction of the tibia using Taylor Spatial Frames shows that CT offers an interesting potential means of quantitatively monitoring the patient's treatment. Compared with traditional techniques, modern CT scans in conjunction with image processing provide a high-resolution, spatially correct, and three-dimensional measurement system which can be used to quickly and easily assess the patient's treatment at low cost to the patient and hospital.
LaPlante, Carolyn; Smith, Sandi; Kotowski, Michael; Nazione, Samantha; Stohl, Cynthia; Prestin, Abby; So, Jiyeon; Nabi, Robin
2012-01-01
Memorable message research examines interpersonal messages “…remembered for extremely long periods of time and which people perceive as a major influence on the course of their lives” (Knapp, Stohl, & Reardon, 1981, p. 27). They can also guide actions, such as health behaviors. This exploratory research examined self-reported memorable messages about breast cancer to determine if they were framed, emphasizing either the benefits (gain-framed) or the costs (loss-framed) of a behavior. About one-fourth of the messages were framed, with most being gain-framed. The messages tended to emphasize early detection actions. Study limitations and implications for future research are discussed. PMID:22539867
ERIC Educational Resources Information Center
Brulle, Robert J.; Benford, Robert D.
2012-01-01
One enduring question in social movements research is the relationship between cultural representations and organizational structure. In this article, we examine the development of different discursive frames over time, and how such frame shifts affect movement structure and practices. This approach seeks to illuminate the dialectical interplay…
ERIC Educational Resources Information Center
Bannister, Nicole A.
2009-01-01
This dissertation seeks to understand how teachers learn through interactions in newly formed workplace communities by examining how mathematics teachers engaged in equity-oriented reforms frame problems of practice. It examines how teachers' framings develop over time, and how teachers' shifting frames connect to their learning in a community of…
40 CFR 260.34 - Standards and criteria for non-waste determinations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... reasonable time frame and ensure that the hazardous secondary material will not be abandoned (for example... statistical or from a health and environmental risk perspective than would otherwise be released by the... hazardous secondary material in a reasonable time frame and ensure that the hazardous secondary material...
User's manual for SYNC: A FORTRAN program for merging and time-synchronizing data
NASA Technical Reports Server (NTRS)
Maine, R. E.
1981-01-01
The FORTRAN 77 computer program SYNC for merging and time synchronizing data is described. The program SYNC reads one or more input files which contain either synchronous data frames or time-tagged data points, which can be compressed. The program decompresses and time synchronizes the data, correcting for any channel time skews. Interpolation and hold last value synchronization algorithms are available. The output from SYNC is a file of time synchronized data frames at any requested sample rate.
Czaban, Marcin; Berry, Marc P.; Nirmalan, Prajeshan; Brown, Richard; Birdseye, Adam; Woroszyl, Asia; Chapman, Julia; Kent, Brian D.; Hart, Nicholas; Rossi, Gian Paolo; Steier, Joerg
2018-01-01
Background Continuous positive airway pressure (CPAP), the best available treatment for obstructive sleep apnea (OSA), requires long-term compliance to be effective. Behavioral interventions may be used to improve adherence to CPAP. We aimed to investigate whether positive or negative message framing impacts on CPAP compliance in patients with OSA, when compared to standard care. Methods Consenting patients with confirmed OSA were randomly allocated to receive along with their CPAP either positively or negatively framed messages (Pos; Neg), or standard care (Con). Standardized motivational messages were read out to patients during an initial teaching session and through weekly telephone calls. Patients’ compliance data were reviewed 2 and 6 weeks following CPAP initiation. Results We randomized 112 patients to groups that were matched for age, BMI, and OSA severity. The positively framed group (Pos) showed greater CPAP usage after 2 weeks (total use 53.7±31.4 hours) as compared to the negatively framed and the control group (35.6±27.4 and 40.8±33.5 hours, P<0.05); however, no differences were seen at 6 weeks. There were more dropouts in the control group than in either framed groups (Pos n=5; Neg n=8; Con n=11; P<0.05). Conclusions Positively framed messages can improve CPAP adherence in patients with OSA in the short-term; however, strategies for implementing its long-term use need to be developed. PMID:29445540
SIRTF Focal Plane Survey: A Pre-flight Error Analysis
NASA Technical Reports Server (NTRS)
Bayard, David S.; Brugarolas, Paul B.; Boussalis, Dhemetrios; Kang, Bryan H.
2003-01-01
This report contains a pre-flight error analysis of the calibration accuracies expected from implementing the currently planned SIRTF focal plane survey strategy. The main purpose of this study is to verify that the planned strategy will meet focal plane survey calibration requirements (as put forth in the SIRTF IOC-SV Mission Plan [4]), and to quantify the actual accuracies expected. The error analysis was performed by running the Instrument Pointing Frame (IPF) Kalman filter on a complete set of simulated IOC-SV survey data, and studying the resulting propagated covariances. The main conclusion of this study is that the all focal plane calibration requirements can be met with the currently planned survey strategy. The associated margins range from 3 to 95 percent, and tend to be smallest for frames having a 0.14" requirement, and largest for frames having a more generous 0.28" (or larger) requirement. The smallest margin of 3 percent is associated with the IRAC 3.6 and 5.8 micron array centers (frames 068 and 069), and the largest margin of 95 percent is associated with the MIPS 160 micron array center (frame 087). For pointing purposes, the most critical calibrations are for the IRS Peakup sweet spots and short wavelength slit centers (frames 019, 023, 052, 028, 034). Results show that these frames are meeting their 0.14" requirements with an expected accuracy of approximately 0.1", which corresponds to a 28 percent margin.
Heo, Min Sook; Rakowski, Cathy A
2014-05-01
Korean feminists are keenly aware that transnational feminists emphasize a human rights framework to eradicate violence against women. But in the 1990s, they based their anti-domestic violence campaign on a frame of "preservation of the family" because it was more culturally resonant at the time than a human rights frame. The results include passage of two legislative Acts, failure to implement as intended, and a continued search for a more effective frame. Ironically, the human rights frame has re-emerged as a possible solution. © The Author(s) 2014.
As time passes by: Observed motion-speed and psychological time during video playback.
Nyman, Thomas Jonathan; Karlsson, Eric Per Anders; Antfolk, Jan
2017-01-01
Research shows that psychological time (i.e., the subjective experience and assessment of the passage of time) is malleable and that the central nervous system re-calibrates temporal information in accordance with situational factors so that psychological time flows slower or faster. Observed motion-speed (e.g., the visual perception of a rolling ball) is an important situational factor which influences the production of time estimates. The present study examines previous findings showing that observed slow and fast motion-speed during video playback respectively results in over- and underproductions of intervals of time. Here, we investigated through three separate experiments: a) the main effect of observed motion-speed during video playback on a time production task and b) the interactive effect of the frame rate (frames per second; fps) and motion-speed during video playback on a time production task. No main effect of video playback-speed or interactive effect between video playback-speed and frame rate was found on time production.
As time passes by: Observed motion-speed and psychological time during video playback
Karlsson, Eric Per Anders; Antfolk, Jan
2017-01-01
Research shows that psychological time (i.e., the subjective experience and assessment of the passage of time) is malleable and that the central nervous system re-calibrates temporal information in accordance with situational factors so that psychological time flows slower or faster. Observed motion-speed (e.g., the visual perception of a rolling ball) is an important situational factor which influences the production of time estimates. The present study examines previous findings showing that observed slow and fast motion-speed during video playback respectively results in over- and underproductions of intervals of time. Here, we investigated through three separate experiments: a) the main effect of observed motion-speed during video playback on a time production task and b) the interactive effect of the frame rate (frames per second; fps) and motion-speed during video playback on a time production task. No main effect of video playback-speed or interactive effect between video playback-speed and frame rate was found on time production. PMID:28614353
Li, Kin-Kit; Cheng, Sheung-Tak; Fung, Helene H
2014-02-01
This study compared message-framing effects on physical activity (PA) across age and gender groups. Participants included 111 younger and 100 older adults (68% were women), randomly assigned to read gain-framed or loss-framed PA messages in promotion pamphlets, and who wore accelerometers for the following 14 days. Using regression analyses controlling for demographic and health factors, we found significant age-by-gender-by-framing interactions predicting self-report (B = -4.39, p = .01) and accelerometer-assessed PA (B = -2.44, p = .02) during the follow-up period. Gain-framed messages were more effective than loss-framed messages in promoting PA behaviors only among older men. We speculated that the age-related positivity effect, as well as the age and gender differences in issue involvement, explained the group differences in framing. In addition, more time availability and higher self-efficacy among older men might have contributed to the results.
NASA Astrophysics Data System (ADS)
Wu, Xiaoping; Abbondanza, Claudio; Altamimi, Zuheir; Chin, T. Mike; Collilieux, Xavier; Gross, Richard S.; Heflin, Michael B.; Jiang, Yan; Parker, Jay W.
2015-05-01
The current International Terrestrial Reference Frame is based on a piecewise linear site motion model and realized by reference epoch coordinates and velocities for a global set of stations. Although linear motions due to tectonic plates and glacial isostatic adjustment dominate geodetic signals, at today's millimeter precisions, nonlinear motions due to earthquakes, volcanic activities, ice mass losses, sea level rise, hydrological changes, and other processes become significant. Monitoring these (sometimes rapid) changes desires consistent and precise realization of the terrestrial reference frame (TRF) quasi-instantaneously. Here, we use a Kalman filter and smoother approach to combine time series from four space geodetic techniques to realize an experimental TRF through weekly time series of geocentric coordinates. In addition to secular, periodic, and stochastic components for station coordinates, the Kalman filter state variables also include daily Earth orientation parameters and transformation parameters from input data frames to the combined TRF. Local tie measurements among colocated stations are used at their known or nominal epochs of observation, with comotion constraints applied to almost all colocated stations. The filter/smoother approach unifies different geodetic time series in a single geocentric frame. Fragmented and multitechnique tracking records at colocation sites are bridged together to form longer and coherent motion time series. While the time series approach to TRF reflects the reality of a changing Earth more closely than the linear approximation model, the filter/smoother is computationally powerful and flexible to facilitate incorporation of other data types and more advanced characterization of stochastic behavior of geodetic time series.
Motion Versus Fixed Distraction of the Joint in the Treatment of Ankle Osteoarthritis
Saltzman, Charles L.; Hillis, Stephen L.; Stolley, Mary P.; Anderson, Donald D.; Amendola, Annunziato
2012-01-01
Background: Initial reports have shown the efficacy of fixed distraction for the treatment of ankle osteoarthritis. We hypothesized that allowing ankle motion during distraction would result in significant improvements in outcomes compared with distraction without ankle motion. Methods: We conducted a prospective randomized controlled trial comparing the outcomes for patients with advanced ankle osteoarthritis who were managed with anterior osteophyte removal and either (1) fixed ankle distraction or (2) ankle distraction permitting joint motion. Thirty-six patients were randomized to treatment with either fixed distraction or distraction with motion. The patients were followed for twenty-four months after frame removal. The Ankle Osteoarthritis Scale (AOS) was the main outcome variable. Results: Two years after frame removal, subjects in both groups showed significant improvement compared with the status before treatment (p < 0.02 for both groups). The motion-distraction group had significantly better AOS scores than the fixed-distraction group at twenty-six, fifty-two, and 104 weeks after frame removal (p < 0.01 at each time point). At 104 weeks, the motion-distraction group had an overall mean improvement of 56.6% in the AOS score, whereas the fixed-distraction group had a mean improvement of 22.9% (p < 0.01). Conclusion: Distraction improved the patient-reported outcomes of treatment of ankle osteoarthritis. Adding ankle motion to distraction showed an early and sustained beneficial effect on outcome. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. PMID:22637202
Real-time unmanned aircraft systems surveillance video mosaicking using GPU
NASA Astrophysics Data System (ADS)
Camargo, Aldo; Anderson, Kyle; Wang, Yi; Schultz, Richard R.; Fevig, Ronald A.
2010-04-01
Digital video mosaicking from Unmanned Aircraft Systems (UAS) is being used for many military and civilian applications, including surveillance, target recognition, border protection, forest fire monitoring, traffic control on highways, monitoring of transmission lines, among others. Additionally, NASA is using digital video mosaicking to explore the moon and planets such as Mars. In order to compute a "good" mosaic from video captured by a UAS, the algorithm must deal with motion blur, frame-to-frame jitter associated with an imperfectly stabilized platform, perspective changes as the camera tilts in flight, as well as a number of other factors. The most suitable algorithms use SIFT (Scale-Invariant Feature Transform) to detect the features consistent between video frames. Utilizing these features, the next step is to estimate the homography between two consecutives video frames, perform warping to properly register the image data, and finally blend the video frames resulting in a seamless video mosaick. All this processing takes a great deal of resources of resources from the CPU, so it is almost impossible to compute a real time video mosaic on a single processor. Modern graphics processing units (GPUs) offer computational performance that far exceeds current CPU technology, allowing for real-time operation. This paper presents the development of a GPU-accelerated digital video mosaicking implementation and compares it with CPU performance. Our tests are based on two sets of real video captured by a small UAS aircraft; one video comes from Infrared (IR) and Electro-Optical (EO) cameras. Our results show that we can obtain a speed-up of more than 50 times using GPU technology, so real-time operation at a video capture of 30 frames per second is feasible.
Gabriel, Kara I; Williamson, Ashley
2010-12-01
Framing uncertain scenarios to emphasize potential positive or negative elements influences decision making and behavior. The current experiment investigated sex differences in framing effects on risk-taking propensity in a modified version of the Balloon Analogue Risk Task (BART). Male and female undergraduates completed questionnaires on sensation seeking, impulsiveness, and risk and benefit perception prior to viewing one of three framing conditions for the BART: (1) positively-framed instructions emphasizing the ability to earn money if balloons were inflated to large size; (2) negatively framed instructions emphasizing the possibility that money could be lost if balloons were inflated to bursting; and (3) completely framed instructions noting both possible outcomes. Results revealed correlations between BART performance and impulsiveness for both sexes. Compared to positive and complete framing, negatively framed instructions decreased balloon inflation time in women but not men, indicating sex differences in response to treatments designed to alter risk-taking behavior.
NASA Astrophysics Data System (ADS)
Xie, Yi; Kopeikin, Sergei
2010-01-01
We construct a set of reference frames for description of the orbital and rotational motion of the Moon. We use a scalar-tensor theory of gravity depending on two parameters of the parametrized post-Newtonian (PPN) formalism and utilize the concepts of the relativistic resolutions on reference frames adopted by the International Astronomical Union in 2000. We assume that the solar system is isolated and space-time is asymptotically flat. The primary reference frame has the origin at the solar-system barycenter (SSB) and spatial axes are going to infinity. The SSB frame is not rotating with respect to distant quasars. The secondary reference frame has the origin at the Earth-Moon barycenter (EMB). The EMB frame is local with its spatial axes spreading out to the orbits of Venus and Mars and not rotating dynamically in the sense that both the Coriolis and centripetal forces acting on a free-falling test particle, moving with respect to the EMB frame, are excluded. Two other local frames, the geocentric (GRF) and the selenocentric (SRF) frames, have the origin at the center of mass of the Earth and Moon respectively. They are both introduced in order to connect the coordinate description of the lunar motion, observer on the Earth, and a retro-reflector on the Moon to the observable quantities which are the proper time and the laser-ranging distance. We solve the gravity field equations and find the metric tensor and the scalar field in all frames. We also derive the post-Newtonian coordinate transformations between the frames and analyze the residual gauge freedom of the solutions of the field equations. We discuss the gravitomagnetic effects in the barycentric equations of the motion of the Moon and argue that they are beyond the current accuracy of lunar laser ranging (LLR) observations.
SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, S; Rottmann, J; Berbeco, R
2014-06-01
Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantommore » moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.« less
Space Shuttle Main Engine Propellant Path Leak Detection Using Sequential Image Processing
NASA Technical Reports Server (NTRS)
Smith, L. Montgomery; Malone, Jo Anne; Crawford, Roger A.
1995-01-01
Initial research in this study using theoretical radiation transport models established that the occurrence of a leak is accompanies by a sudden but sustained change in intensity in a given region of an image. In this phase, temporal processing of video images on a frame-by-frame basis was used to detect leaks within a given field of view. The leak detection algorithm developed in this study consists of a digital highpass filter cascaded with a moving average filter. The absolute value of the resulting discrete sequence is then taken and compared to a threshold value to produce the binary leak/no leak decision at each point in the image. Alternatively, averaging over the full frame of the output image produces a single time-varying mean value estimate that is indicative of the intensity and extent of a leak. Laboratory experiments were conducted in which artificially created leaks on a simulated SSME background were produced and recorded from a visible wavelength video camera. This data was processed frame-by-frame over the time interval of interest using an image processor implementation of the leak detection algorithm. In addition, a 20 second video sequence of an actual SSME failure was analyzed using this technique. The resulting output image sequences and plots of the full frame mean value versus time verify the effectiveness of the system.
Optical Diagnostic System For Observation Of Laser-Produced Shock Waves
NASA Astrophysics Data System (ADS)
Wilke, Mark D.; Stone, Sidney N.
1980-11-01
Several standard plasma and gas dynamic diagnostic techniques have been integrated into a system for observing the formation and propagation of high-power Nd:glass-laser generated one- and two-dimensional shockwaves in air from 0.1 torr to atmospheric pres-sures. Diagnostics include either single-frame, two-wavelength holographic ruby-laser interferometry or single-frame, single-wavelength interferometry with ten frames of shadow-graphy. Streaks or ten frames of the early luminous shocked region also are taken on all shots, as well as time-resolved luminosity measurements using high-speed biplanar vacuum photodiodes with various wavelength interference filters. Shadowgraphy frames are 200-ns long at 1-μs intervals, while emission frames are variable with a maximum 10-ns exposure and 50-ns interval. Both the streak mode and emission measurements with the vacuum diode allow subnanosecond time resolution. The interferometry provides 20-ns exposures from 500 ns to late times. Methods for reducing and interpreting the data have been, or are currently being, developed. Interactive computer programs for digitizing the fringe patterns provide fringe-shift profiles for Abel inversion. This has provided neutral gas and electron density information in the spherical, one-dimensional cases. Diagrams and photographs of the experiment will be shown as well as examples of the data that have been taken. Methods for data reduction will be outlined and some of the results shown.
Theoretically Investigating the Nature of Spacetime- A grand definition of what clocks measure
NASA Astrophysics Data System (ADS)
Egie, Meru
Einstein's special theory of relativity established time as a dimension of reality, explaining physically the mathematical stipulations of Lorentz transformation equations that are required to keep the validity of Maxwell's equations of light and explain the null result of Michelson-Morley experiment. Our current understanding of time is relativistic, that is time is not absolute but runs differently depending on the frame of reference, yet this description uncovers so little about the fundamental reality of time. Using mathematical arguments derived from a simple thought experiment, both Lorentz transformation equations and Einstein's far reaching conclusions of his 1905 paper on the electrodynamics of moving bodies are obtained with arguments that suggest no prior knowledge of both Einstein and Lorentz works. This work attempts uncovering the fundamental nature of what clocks measure and a major implication of this is that the fourth dimension could just be a persistent illusion caused by the existence of space. Gratitude to Mr. Jon Egie for his support and Aghogo Rita for her listening ears.
Economic Burden of Obesity: A Systematic Literature Review
Tremmel, Maximilian; Gerdtham, Ulf-G.; Nilsson, Peter M.; Saha, Sanjib
2017-01-01
Background: The rising prevalence of obesity represents an important public health issue. An assessment of its costs may be useful in providing recommendations for policy and decision makers. This systematic review aimed to assess the economic burden of obesity and to identify, measure and describe the different obesity-related diseases included in the selected studies. Methods: A systematic literature search of studies in the English language was carried out in Medline (PubMed) and Web of Science databases to select cost-of-illness studies calculating the cost of obesity in a study population aged ≥18 years with obesity, as defined by a body mass index of ≥30 kg/m², for the whole selected country. The time frame for the analysis was January 2011 to September 2016. Results: The included twenty three studies reported a substantial economic burden of obesity in both developed and developing countries. There was considerable heterogeneity in methodological approaches, target populations, study time frames, and perspectives. This prevents an informative comparison between most of the studies. Specifically, there was great variety in the included obesity-related diseases and complications among the studies. Conclusions: There is an urgent need for public health measures to prevent obesity in order to save societal resources. Moreover, international consensus is required on standardized methods to calculate the cost of obesity to improve homogeneity and comparability. This aspect should also be considered when including obesity-related diseases. PMID:28422077
Helicopter emergency medical services accident rates in different international air rescue systems
Hinkelbein, J; Schwalbe, M; Genzwuerker, HV
2010-01-01
Aim Each year approximately two to four helicopter emergency medical services (HEMS) crashes occur in Germany. The aim of the present study was to compare crash rates and fatal crash rates in Germany to rates in other countries. Materials and methods A MEDLINE search from 1970 to 2009 was performed using combinations of the keywords “HEMS”, “rescue helicopter”, “accident”, “accident rate”, “crash”, and “crash rate”. The search was supplemented by additional published data. Data were compared on the basis of 10,000 missions and 100,000 helicopter flying hours. These data were allocated to specific time frames for analyis. Results Eleven relevant studies were identified. Five studies (three from Germany, one from the US, one from Australia) analyzing HEMS accidents on the basis of 10,000 missions were identified. Crash rates per 10,000 missions ranged between 0.4 and 3.05 and fatal crash rates between 0.04 and 2.12. In addition, nine studies (six from the US, two from Germany, one from Australia) used 100,000 flying hours as a denominator. Here, crash rates ranged between 1.7 and 13.4 and fatal crash rates between 0.91 and 4.7. Conclusions Data and accident rates were inhomogeneous and differed significantly. Data analysis was impeded by publication of mean data, use of different time frames, and differences in HEMS systems. PMID:27147837
Code of Federal Regulations, 2010 CFR
2010-07-01
... the time of the determination, to deduct up to 15%, or a greater amount if agreed to by the employee... procedures; (3) Establish time frames for employees to request a waiver in writing and for the bureau to review the waiver request. These time frames must take into consideration the responsibilities of the...
Time and flow-direction responses of shear-styress-sensitive liquid crystal coatings
NASA Technical Reports Server (NTRS)
Reda, Daniel C.; Muraqtore, J. J.; Heinick, James T.
1994-01-01
Time and flow-direction responses of shear-stress liquid crystal coatings were exploresd experimentally. For the time-response experiments, coatings were exposed to transient, compressible flows created during the startup and off-design operation of an injector-driven supersonic wind tunnel. Flow transients were visualized with a focusing schlieren system and recorded with a 100 frame/s color video camera.
NASA Astrophysics Data System (ADS)
Luo, Lin-Bo; An, Sang-Woo; Wang, Chang-Shuai; Li, Ying-Chun; Chong, Jong-Wha
2012-09-01
Digital cameras usually decrease exposure time to capture motion-blur-free images. However, this operation will generate an under-exposed image with a low-budget complementary metal-oxide semiconductor image sensor (CIS). Conventional color correction algorithms can efficiently correct under-exposed images; however, they are generally not performed in real time and need at least one frame memory if they are implemented by hardware. The authors propose a real-time look-up table-based color correction method that corrects under-exposed images with hardware without using frame memory. The method utilizes histogram matching of two preview images, which are exposed for a long and short time, respectively, to construct an improved look-up table (ILUT) and then corrects the captured under-exposed image in real time. Because the ILUT is calculated in real time before processing the captured image, this method does not require frame memory to buffer image data, and therefore can greatly save the cost of CIS. This method not only supports single image capture, but also bracketing to capture three images at a time. The proposed method was implemented by hardware description language and verified by a field-programmable gate array with a 5 M CIS. Simulations show that the system can perform in real time with a low cost and can correct the color of under-exposed images well.
Effects of context on risk taking and decision times in obsessive-compulsive disorder.
Sip, Kamila E; Muratore, Alexandra F; Stern, Emily R
2016-04-01
Despite the fact that OCD patients show altered decision making in everyday life, few studies have investigated how patients make risky decisions and what contextual factors impact choices. We investigated cognitive context with the use of the "framing effect" task, which investigates decision making based on whether monetarily equivalent choice options are framed in terms of a potential to either lose (lose $20 out of $50) or gain (gain $30 out of $50) money. In addition, we manipulated social context by providing positive or neutral feedback on subjects' choices. Overall, participants were risk taking for options framed in terms of potential loss and risk averse for options framed in terms of potential gain (the classic framing effect). Although OCD patients were generally more risk averse, the effect of the frame on choices did not differ significantly from healthy participants and choices were not impacted by social context. Within OCD patients, greater self-reported indecisiveness was associated with a larger effect of the frame on choices. OCD patients were also significantly slower to make choices in the loss compared to gain frame, an effect that was not observed among healthy participants. Overall, our results suggest that the framing of choice options has a differential effect on decision times but not the actual choices made by OCD patients, and that patients are not sensitive to social feedback when making choices. The correlation between indecisiveness and the framing effect in OCD suggests that further work interrogating the relationship between specific symptoms and decision making among patients may yield new insights into the disorder. Copyright © 2016 Elsevier Ltd. All rights reserved.
The Effect of Hyperbaric Oxygen on the Growth of Mucor sp. Aspergillus fumigatus.
1980-02-01
designations are for controls. 12 mamo 7<)U 4/ Figure 2. Aspergillus fumigatus Top Frame - Hyphae at day 2. Middle Frame - Plyphae with developing...conidiaphores, day 3. L~ower Frame - Hyphae with conidiophores and conidia, day 4. Time~ designations are for co~ntrols. 14 0 lOum Figure 3. Grouth curves
ERIC Educational Resources Information Center
Engle, Randi A.; Lam, Diane P.; Meyer, Xenia S.; Nix, Sarah E.
2012-01-01
When contexts are framed expansively, students are positioned as actively contributing to larger conversations that extend across time, places, and people. A set of recent studies provides empirical evidence that the expansive framing of contexts can foster transfer. In this article, we present five potentially complementary explanations for how…
Spot-Welding Gun Is Easy To Use
NASA Technical Reports Server (NTRS)
Morgan, Gene E.; Nguyen, Francis H.
1991-01-01
Electrical-resistance spot-welding gun designed to produce more welds per unit time by decreasing technician's effort and fatigue. Vacuum cups on frame secure welding gun to workpiece while compressed air drives welding tip against workpiece to make spot resistance weld. When weld completed, vacuum in frame cups released so frame and gun moved to position of next spot weld.
High-Speed Large-Alphabet Quantum Key Distribution Using Photonic Integrated Circuits
2014-01-28
polarizing beam splitter, TDC: time-to-digital converter. Extra&loss& photon/bin frame size QSER secure bpp ECC secure&key&rate& none& 0.0031 64 14...to-digital converter. photon/frame frame size QSER secure bpp ECC secure&key& rate& 1.3 16 9.5 % 2.9 layered LDPC 7.3&Mbps& Figure 24: Operating
Imaging the Frame: Media Representations of Teachers, Their Unions, NCLB, and Education Reform
ERIC Educational Resources Information Center
Goldstein, Rebecca A.
2011-01-01
This article examines the political discourse surrounding NCLB, educational reform, and how that discourse shaped perceptions of public education during the Bush Administration. Examining mass media campaigns in the New York Times and Time Magazine, the article demonstrates how the media has visually and textually framed and reinforced NCLB and…
2005-02-01
2004. 3. Pesavento , A. and A. Lorenz. Real time stain imaging and in vivo applications in prostate cancer, in IEEE Ultrasonics Symposium. 2001. 4...Symposium. 2000. 6. Pesavento A, L.A., Ermert H, Sommerfeld H, Garcia-Schurmann M, Senge Th, Philippou S. Frame-to-frame statistics of real-time strain
21 CFR 814.40 - Time frames for reviewing a PMA.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...
21 CFR 814.40 - Time frames for reviewing a PMA.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...
21 CFR 814.40 - Time frames for reviewing a PMA.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES PREMARKET APPROVAL OF MEDICAL DEVICES FDA Action on a PMA § 814.40 Time frames for... the applicant does not submit a major amendment, FDA will review the PMA and, after receiving the report and recommendation of the appropriate FDA advisory committee, send the applicant an approval order...
Suitability of the echo-time-shift method as laboratory standard for thermal ultrasound dosimetry
NASA Astrophysics Data System (ADS)
Fuhrmann, Tina; Georg, Olga; Haller, Julian; Jenderka, Klaus-Vitold
2017-03-01
Ultrasound therapy is a promising, non-invasive application with potential to significantly improve cancer therapies like surgery, viro- or immunotherapy. This therapy needs faster, cheaper and more easy-to-handle quality assurance tools for therapy devices as well as possibilities to verify treatment plans and for dosimetry. This limits comparability and safety of treatments. Accurate spatial and temporal temperature maps could be used to overcome these shortcomings. In this contribution first results of suitability and accuracy investigations of the echo-time-shift method for two-dimensional temperature mapping during and after sonication are presented. The analysis methods used to calculate time-shifts were a discrete frame-to-frame and a discrete frame-to-base-frame algorithm as well as a sigmoid fit for temperature calculation. In the future accuracy could be significantly enhanced by using continuous methods for time-shift calculation. Further improvements can be achieved by improving filtering algorithms and interpolation of sampled diagnostic ultrasound data. It might be a comparatively accurate, fast and affordable method for laboratory and clinical quality control.
NASA Astrophysics Data System (ADS)
Zhong, Fan; Li, Jensen; Liu, Hui; Zhu, Shining
2018-06-01
General relativity uses curved space-time to describe accelerating frames. The movement of particles in different curved space-times can be regarded as equivalent physical processes based on the covariant transformation between different frames. In this Letter, we use one-dimensional curved metamaterials to mimic accelerating particles in curved space-times. The different curved shapes of structures are used to mimic different accelerating frames. The different geometric phases along the structure are used to mimic different movements in the frame. Using the covariant principle of general relativity, we can obtain equivalent nanostructures based on space-time transformations, such as the Lorentz transformation and conformal transformation. In this way, many covariant structures can be found that produce the same surface plasmon fields when excited by spin photons. A new kind of accelerating beam, the Rindler beam, is obtained based on the Rindler metric in gravity. Very large effective indices can be obtained in such systems based on geometric-phase gradient. This general covariant design method can be extended to many other optical media.
Framing the ecosystem concept through a longitudinal study of developments in science and policy.
Aggestam, Filip
2015-08-01
This paper examines how scientific literature and policy documents frame the ecosystem concept and how these frames have shaped scientific dialogue and policy making over time. This was achieved by developing a frame typology, as a basis for organizing relevant value expressions, to assess how different frames have altered perspectives of the ecosystem concept. The frame typology and analysis is based on a semi-grounded and longitudinal document analysis of scientific literature and policy documents using the ecosystem concept. Despite changing discourses and public priorities (e.g., cultural constructs of biodiversity) both science and policy documents are characterized by stable value systems that have not changed substantially since the 1930s. These value systems were defined based on ethical principles that delineate 6 core frames: humans first, dual systems, eco-science, eco-holism, animals first, and multicentrism. Specific crises (e.g., climate change) and cross-disciplinary uptake and re-uptake of, for example, the ecosystem services concept, have brought new perspectives to the forefront of public discourse. These developments triggered changes in the core frames that, rather than being value based, are based on how the ecosystem is conceptualized under fixed value systems and over time. Fourteen subframes were developed to reflect these longitudinal changes. There are as such clear framing effects in both scientific literature and in policy. Ecosystem research is for instance often characterized by unstated value judgments even though the scientific community does not make these explicit. In contrast, policy documents are characterized by clear value expressions but are principally management driven and human centered. © 2015 Society for Conservation Biology.
Hardware accelerator design for change detection in smart camera
NASA Astrophysics Data System (ADS)
Singh, Sanjay; Dunga, Srinivasa Murali; Saini, Ravi; Mandal, A. S.; Shekhar, Chandra; Chaudhury, Santanu; Vohra, Anil
2011-10-01
Smart Cameras are important components in Human Computer Interaction. In any remote surveillance scenario, smart cameras have to take intelligent decisions to select frames of significant changes to minimize communication and processing overhead. Among many of the algorithms for change detection, one based on clustering based scheme was proposed for smart camera systems. However, such an algorithm could achieve low frame rate far from real-time requirements on a general purpose processors (like PowerPC) available on FPGAs. This paper proposes the hardware accelerator capable of detecting real time changes in a scene, which uses clustering based change detection scheme. The system is designed and simulated using VHDL and implemented on Xilinx XUP Virtex-IIPro FPGA board. Resulted frame rate is 30 frames per second for QVGA resolution in gray scale.
Individual differences in drivers' cognitive processing of road safety messages.
Kaye, Sherrie-Anne; White, Melanie J; Lewis, Ioni M
2013-01-01
Using Gray and McNaughton's (2000) revised reinforcement sensitivity theory (r-RST), we examined the influence of personality on processing of words presented in gain-framed and loss-framed anti-speeding messages and how the processing biases associated with personality influenced message acceptance. The r-RST predicts that the nervous system regulates personality and that behaviour is dependent upon the activation of the behavioural activation system (BAS), activated by reward cues and the fight-flight-freeze system (FFFS), activated by punishment cues. According to r-RST, individuals differ in the sensitivities of their BAS and FFFS (i.e., weak to strong), which in turn leads to stable patterns of behaviour in the presence of rewards and punishments, respectively. It was hypothesised that individual differences in personality (i.e., strength of the BAS and the FFFS) would influence the degree of both message processing (as measured by reaction time to previously viewed message words) and message acceptance (measured three ways by perceived message effectiveness, behavioural intentions, and attitudes). Specifically, it was anticipated that, individuals with a stronger BAS would process the words presented in the gain-frame messages faster than those with a weaker BAS and individuals with a stronger FFFS would process the words presented in the loss-frame messages faster than those with a weaker FFFS. Further, it was expected that greater processing (faster reaction times) would be associated with greater acceptance for that message. Driver licence holding students (N=108) were recruited to view one of four anti-speeding messages (i.e., social gain-frame, social loss-frame, physical gain-frame, and physical loss-frame). A computerised lexical decision task assessed participants' subsequent reaction times to message words, as an indicator of the extent of processing of the previously viewed message. Self-report measures assessed personality and the three message acceptance measures. As predicted, the degree of initial processing of the content of the social gain-framed message mediated the relationship between the reward sensitive trait and message effectiveness. Initial processing of the physical loss-framed message partially mediated the relationship between the punishment sensitive trait and both message effectiveness and behavioural intention ratings. These results show that reward sensitivity and punishment sensitivity traits influence cognitive processing of gain-framed and loss-framed message content, respectively, and subsequently, message effectiveness and behavioural intention ratings. Specifically, a range of road safety messages (i.e., gain-frame and loss-frame messages) could be designed which align with the processing biases associated with personality and which would target those individuals who are sensitive to rewards and those who are sensitive to punishments. Copyright © 2012 Elsevier Ltd. All rights reserved.
Simulations of VLBI observations of a geodetic satellite providing co-location in space
NASA Astrophysics Data System (ADS)
Anderson, James M.; Beyerle, Georg; Glaser, Susanne; Liu, Li; Männel, Benjamin; Nilsson, Tobias; Heinkelmann, Robert; Schuh, Harald
2018-02-01
We performed Monte Carlo simulations of very-long-baseline interferometry (VLBI) observations of Earth-orbiting satellites incorporating co-located space-geodetic instruments in order to study how well the VLBI frame and the spacecraft frame can be tied using such measurements. We simulated observations of spacecraft by VLBI observations, time-of-flight (TOF) measurements using a time-encoded signal in the spacecraft transmission, similar in concept to precise point positioning, and differential VLBI (D-VLBI) observations using angularly nearby quasar calibrators to compare their relative performance. We used the proposed European Geodetic Reference Antenna in Space (E-GRASP) mission as an initial test case for our software. We found that the standard VLBI technique is limited, in part, by the present lack of knowledge of the absolute offset of VLBI time to Coordinated Universal Time at the level of microseconds. TOF measurements are better able to overcome this problem and provide frame ties with uncertainties in translation and scale nearly a factor of three smaller than those yielded from VLBI measurements. If the absolute time offset issue can be resolved by external means, the VLBI results can be significantly improved and can come close to providing 1 mm accuracy in the frame tie parameters. D-VLBI observations with optimum performance assumptions provide roughly a factor of two higher uncertainties for the E-GRASP orbit. We additionally simulated how station and spacecraft position offsets affect the frame tie performance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Popple, R; Bredel, M; Brezovich, I
Purpose: To compare the accuracy of CT-MR registration using a mutual information method with registration using a frame-based localizer box. Methods: Ten patients having the Leksell head frame and scanned with a modality specific localizer box were imported into the treatment planning system. The fiducial rods of the localizer box were contoured on both the MR and CT scans. The skull was contoured on the CT images. The MR and CT images were registered by two methods. The frame-based method used the transformation that minimized the mean square distance of the centroids of the contours of the fiducial rods frommore » a mathematical model of the localizer. The mutual information method used automated image registration tools in the TPS and was restricted to a volume-of-interest defined by the skull contours with a 5 mm margin. For each case, the two registrations were adjusted by two evaluation teams, each comprised of an experienced radiation oncologist and neurosurgeon, to optimize alignment in the region of the brainstem. The teams were blinded to the registration method. Results: The mean adjustment was 0.4 mm (range 0 to 2 mm) and 0.2 mm (range 0 to 1 mm) for the frame and mutual information methods, respectively. The median difference between the frame and mutual information registrations was 0.3 mm, but was not statistically significant using the Wilcoxon signed rank test (p=0.37). Conclusion: The difference between frame and mutual information registration techniques was neither statistically significant nor, for most applications, clinically important. These results suggest that mutual information is equivalent to frame-based image registration for radiosurgery. Work is ongoing to add additional evaluators and to assess the differences between evaluators.« less
Technological viewpoints (frames) about electronic prescribing in physician practices
Agarwal, Ritu; DesRoches, Catherine M; Fischer, Michael A
2010-01-01
Objective Physician practices may adopt and use electronic prescribing (eRx) in response to mandates, incentives, and perceived value of the technology. Yet, for the most part, diffusion has been limited and geographically confined, and even when adopted, use of eRx in many practices has been low. One explanation for this phenomenon is that decision-makers in the practices possess different technological viewpoints (frames) related to eRx and these frames have formed the basis for the adoption decision, expectations about the technology, and patterns of use. In this study eRx technological frames were examined. Design Focus groups, direct observation, and semi-structured interviews were conducted with physicians, practice managers, nurses, and other medical staff. Measurements Focus groups were observed, taped, transcribed, and analyzed to reveal themes. These themes guided the observational visits and subsequent interviews. A triangulation process was used to confirm the findings. Results Seven frames emerged from the qualitative analysis ranging from positive to neutral to negative: (1) eRx as an efficiency and effectiveness enhancing tool; (2) eRx as the harbinger of new practices; (3) eRx as core to the clinical workflow; (4) eRx as an administrative tool; (5) eRx: the artifact; (6) eRx as a necessary evil; and (7) eRx as an unwelcome disruption. Conclusion Frames provide a unique perspective within which to explore the adoption and use of eRx and may explain why perceptions of value vary greatly. Some frames facilitate effective use of eRx while others impose barriers. Electronic prescribing can be viewed as a transitional technology on the path to greater digitization at the physician practice level. Understanding the impact of technological frames on the effectiveness of eRx use may provide lessons for the implementation of future health information technology innovations. PMID:20595310
Benedetti, L. R.; Holder, J. P.; Perkins, M.; ...
2016-02-26
We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement formore » gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. Furthermore, we have developed a device that can be added to the framing camera head to prevent these artifacts.« less
The effects of frame, appeal, and outcome extremity of antismoking messages on cognitive processing.
Leshner, Glenn; Cheng, I-Huei
2009-04-01
Research on the impact of antismoking advertisements in countermarketing cigarette advertising is equivocal. Although many studies examined how different message appeal types influence people's attitudes and behavior, there have been few studies that have explored the mechanism of how individuals attend to and remember antismoking information. This study examined how message attributes of antismoking TV ads (frame, appeal type, and outcome extremity) interacted to influence people's attention (secondary task reaction time) and memory (recognition). Antismoking public service announcements were chosen that were either loss- or gain-framed, had either a health or social appeal, or had either a more or less extreme outcome described in the message. Among the key findings were that loss-framed messages with more extreme outcomes required the most processing resources (i.e., had the slowest secondary task reaction times) and were the best remembered (i.e., were best recognized). These findings indicate ways that different message attributes affect individuals' cognitive processing, and they are discussed in light of prior framing and persuasion research.
Benedetti, L R; Holder, J P; Perkins, M; Brown, C G; Anderson, C S; Allen, F V; Petre, R B; Hargrove, D; Glenn, S M; Simanovskaia, N; Bradley, D K; Bell, P
2016-02-01
We describe an experimental method to measure the gate profile of an x-ray framing camera and to determine several important functional parameters: relative gain (between strips), relative gain droop (within each strip), gate propagation velocity, gate width, and actual inter-strip timing. Several of these parameters cannot be measured accurately by any other technique. This method is then used to document cross talk-induced gain variations and artifacts created by radiation that arrives before the framing camera is actively amplifying x-rays. Electromagnetic cross talk can cause relative gains to vary significantly as inter-strip timing is varied. This imposes a stringent requirement for gain calibration. If radiation arrives before a framing camera is triggered, it can cause an artifact that manifests as a high-intensity, spatially varying background signal. We have developed a device that can be added to the framing camera head to prevent these artifacts.
Quantum reference frames and their applications to thermodynamics.
Popescu, Sandu; Sainz, Ana Belén; Short, Anthony J; Winter, Andreas
2018-07-13
We construct a quantum reference frame, which can be used to approximately implement arbitrary unitary transformations on a system in the presence of any number of extensive conserved quantities, by absorbing any back action provided by the conservation laws. Thus, the reference frame at the same time acts as a battery for the conserved quantities. Our construction features a physically intuitive, clear and implementation-friendly realization. Indeed, the reference system is composed of the same types of subsystems as the original system and is finite for any desired accuracy. In addition, the interaction with the reference frame can be broken down into two-body terms coupling the system to one of the reference frame subsystems at a time. We apply this construction to quantum thermodynamic set-ups with multiple, possibly non-commuting conserved quantities, which allows for the definition of explicit batteries in such cases.This article is part of a discussion meeting issue 'Foundations of quantum mechanics and their impact on contemporary society'. © 2018 The Author(s).
Improved frame-based estimation of head motion in PET brain imaging.
Mukherjee, J M; Lindsay, C; Mukherjee, A; Olivier, P; Shao, L; King, M A; Licho, R
2016-05-01
Head motion during PET brain imaging can cause significant degradation of image quality. Several authors have proposed ways to compensate for PET brain motion to restore image quality and improve quantitation. Head restraints can reduce movement but are unreliable; thus the need for alternative strategies such as data-driven motion estimation or external motion tracking. Herein, the authors present a data-driven motion estimation method using a preprocessing technique that allows the usage of very short duration frames, thus reducing the intraframe motion problem commonly observed in the multiple frame acquisition method. The list mode data for PET acquisition is uniformly divided into 5-s frames and images are reconstructed without attenuation correction. Interframe motion is estimated using a 3D multiresolution registration algorithm and subsequently compensated for. For this study, the authors used 8 PET brain studies that used F-18 FDG as the tracer and contained minor or no initial motion. After reconstruction and prior to motion estimation, known motion was introduced to each frame to simulate head motion during a PET acquisition. To investigate the trade-off in motion estimation and compensation with respect to frames of different length, the authors summed 5-s frames accordingly to produce 10 and 60 s frames. Summed images generated from the motion-compensated reconstructed frames were then compared to the original PET image reconstruction without motion compensation. The authors found that our method is able to compensate for both gradual and step-like motions using frame times as short as 5 s with a spatial accuracy of 0.2 mm on average. Complex volunteer motion involving all six degrees of freedom was estimated with lower accuracy (0.3 mm on average) than the other types investigated. Preprocessing of 5-s images was necessary for successful image registration. Since their method utilizes nonattenuation corrected frames, it is not susceptible to motion introduced between CT and PET acquisitions. The authors have shown that they can estimate motion for frames with time intervals as short as 5 s using nonattenuation corrected reconstructed FDG PET brain images. Intraframe motion in 60-s frames causes degradation of accuracy to about 2 mm based on the motion type.
NASA Astrophysics Data System (ADS)
Pretorius, P. H.; King, Michael A.; Tsui, Benjamin M.; LaCroix, Karen; Xia, Weishi
1998-07-01
This manuscript documents the alteration of the heart model of the MCAT phantom to better represent cardiac motion. The objective of the inclusion of motion was to develop a digital simulation of the heart such that the impact of cardiac motion on single photon emission computed tomography (SPECT) imaging could be assessed and methods of quantitating cardiac function could be investigated. The motion of the dynamic MCAT's heart is modeled by a 128 time frame volume curve. Eight time frames are averaged together to obtain a gated perfusion acquisition of 16 time frames and ensure motion within every time frame. The position of the MCAT heart was changed during contraction to rotate back and forth around the long axis through the center of the left ventricle (LV) using the end systolic time frame as turning point. Simple respiratory motion was also introduced by changing the orientation of the heart model in a 2 dimensional (2D) plane with every time frame. The averaging effect of respiratory motion in a specific time frame was modeled by randomly selecting multiple heart locations between two extreme orientations. Non-gated perfusion phantoms were also generated by averaging over all time frames. Maximal chamber volumes were selected to fit a profile of a normal healthy person. These volumes were changed during contraction of the ventricles such that the increase in volume in the atria compensated for the decrease in volume in the ventricles. The myocardium were modeled to represent shortening of muscle fibers during contraction with the base of the ventricles moving towards a static apex. The apical region was modeled with moderate wall thinning present while myocardial mass was conserved. To test the applicability of the dynamic heart model, myocardial wall thickening was measured using maximum counts and full width half maximum measurements, and compared with published trends. An analytical 3D projector, with attenuation and detector response included, was used to generate radionuclide projection data sets. After reconstruction a linear relationship was obtained between maximum myocardial counts and myocardium thickness, similar to published results. A numeric difference in values from different locations exist due to different amounts of attenuation present. Similar results were obtained for FWHM measurements. Also, a hot apical region on the polar maps without attenuation compensation turns into an apical defect with attenuation compensation. The apical decrease was more prominent in ED than ES due to the change in the partial volume effect. Both of these agree with clinical trends. It is concluded that the dynamic MCAT (dMCAT) phantom can be used to study the influence of various physical parameters on radionuclide perfusion imaging.
Akkas, Oguz; Lee, Cheng Hsien; Hu, Yu Hen; Harris Adamson, Carisa; Rempel, David; Radwin, Robert G
2017-12-01
Two computer vision algorithms were developed to automatically estimate exertion time, duty cycle (DC) and hand activity level (HAL) from videos of workers performing 50 industrial tasks. The average DC difference between manual frame-by-frame analysis and the computer vision DC was -5.8% for the Decision Tree (DT) algorithm, and 1.4% for the Feature Vector Training (FVT) algorithm. The average HAL difference was 0.5 for the DT algorithm and 0.3 for the FVT algorithm. A sensitivity analysis, conducted to examine the influence that deviations in DC have on HAL, found it remained unaffected when DC error was less than 5%. Thus, a DC error less than 10% will impact HAL less than 0.5 HAL, which is negligible. Automatic computer vision HAL estimates were therefore comparable to manual frame-by-frame estimates. Practitioner Summary: Computer vision was used to automatically estimate exertion time, duty cycle and hand activity level from videos of workers performing industrial tasks.
Real-time MRI of the temporomandibular joint at 15 frames per second-A feasibility study.
Krohn, Sebastian; Gersdorff, Nikolaus; Wassmann, Torsten; Merboldt, Klaus-Dietmar; Joseph, Arun A; Buergers, Ralf; Frahm, Jens
2016-12-01
The purpose of this study was to develop and evaluate a novel method for real-time MRI of TMJ function at high temporal resolution and with two different contrasts. Real-time MRI was based on undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion. Real-time MRI movies with T1 contrast were obtained with use of a radiofrequency-spoiled FLASH sequence, while movies with T2/T1 contrast employed a gradient-refocused FLASH version. TMJ function was characterized in 40 randomly selected volunteers by sequential 20s acquisitions of both the right and left joint during voluntary opening and closing of the mouth (in a medial, central and lateral oblique sagittal section perpendicular to the long axis of the condylar head). All studies were performed on a commercial MRI system at 3T using the standard head coil, while online reconstruction was achieved with a bypass computer fully integrated into the MRI system. As a first result, real-time MRI studies of the right and left TMJ were successfully performed in all 40 subjects (80 joints) within a total examination time per subject of only 15min. Secondly, at an in-plane resolution of 0.75mm and 5mm section thickness, the achieved temporal resolution was 66.7ms per image or 15 frames per second. Thirdly, both T1-weighted and T2/T1-weighted real-time MRI movies provided information about TMJ function such as disc position, condyle mobility and disc-condyle relationship. While T1 contrast offers a better delineation of structures during rapid jaw movements, T2/T1 contrast was rated superior for characterizing the articular disc. In conclusion, the proposed real-time MRI method may become a robust and efficient tool for the clinical assessment of TMJ function. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, D; O’Connell, D; Lamb, J
Purpose: To demonstrate real-time dose calculation of free-breathing MRI guided Co−60 treatments, using a motion model and Monte-Carlo dose calculation to accurately account for the interplay between irregular breathing motion and an IMRT delivery. Methods: ViewRay Co-60 dose distributions were optimized on ITVs contoured from free-breathing CT images of lung cancer patients. Each treatment plan was separated into 0.25s segments, accounting for the MLC positions and beam angles at each time point. A voxel-specific motion model derived from multiple fast-helical free-breathing CTs and deformable registration was calculated for each patient. 3D images for every 0.25s of a simulated treatment weremore » generated in real time, here using a bellows signal as a surrogate to accurately account for breathing irregularities. Monte-Carlo dose calculation was performed every 0.25s of the treatment, with the number of histories in each calculation scaled to give an overall 1% statistical uncertainty. Each dose calculation was deformed back to the reference image using the motion model and accumulated. The static and real-time dose calculations were compared. Results: Image generation was performed in real time at 4 frames per second (GPU). Monte-Carlo dose calculation was performed at approximately 1frame per second (CPU), giving a total calculation time of approximately 30 minutes per treatment. Results show both cold- and hot-spots in and around the ITV, and increased dose to contralateral lung as the tumor moves in and out of the beam during treatment. Conclusion: An accurate motion model combined with a fast Monte-Carlo dose calculation allows almost real-time dose calculation of a free-breathing treatment. When combined with sagittal 2D-cine-mode MRI during treatment to update the motion model in real time, this will allow the true delivered dose of a treatment to be calculated, providing a useful tool for adaptive planning and assessing the effectiveness of gated treatments.« less
A real-time dashboard for managing pathology processes
Halwani, Fawaz; Li, Wei Chen; Banerjee, Diponkar; Lessard, Lysanne; Amyot, Daniel; Michalowski, Wojtek; Giffen, Randy
2016-01-01
Context: The Eastern Ontario Regional Laboratory Association (EORLA) is a newly established association of all the laboratory and pathology departments of Eastern Ontario that currently includes facilities from eight hospitals. All surgical specimens for EORLA are processed in one central location, the Department of Pathology and Laboratory Medicine (DPLM) at The Ottawa Hospital (TOH), where the rapid growth and influx of surgical and cytology specimens has created many challenges in ensuring the timely processing of cases and reports. Although the entire process is maintained and tracked in a clinical information system, this system lacks pre-emptive warnings that can help management address issues as they arise. Aims: Dashboard technology provides automated, real-time visual clues that could be used to alert management when a case or specimen is not being processed within predefined time frames. We describe the development of a dashboard helping pathology clinical management to make informed decisions on specimen allocation and tracking. Methods: The dashboard was designed and developed in two phases, following a prototyping approach. The first prototype of the dashboard helped monitor and manage pathology processes at the DPLM. Results: The use of this dashboard helped to uncover operational inefficiencies and contributed to an improvement of turn-around time within The Ottawa Hospital's DPML. It also allowed the discovery of additional requirements, leading to a second prototype that provides finer-grained, real-time information about individual cases and specimens. Conclusion: We successfully developed a dashboard that enables managers to address delays and bottlenecks in specimen allocation and tracking. This support ensures that pathology reports are provided within time frame standards required for high-quality patient care. Given the importance of rapid diagnostics for a number of diseases, the use of real-time dashboards within pathology departments could contribute to improving the quality of patient care beyond EORLA's. PMID:27217974
Role of accentuation in the selection/rejection task framing effect.
Chen, Jing; Proctor, Robert W
2017-04-01
Procedure invariance is a basic assumption of rational theories of choice, however, it has been shown to be violated: Different response modes, or task frames, sometimes reveal opposite preferences. The current study focused on selection and rejection task frames, involving a unique type of problem with enriched and impoverished options, which has previously led to conflicting findings and theoretical explanations: the compatibility hypothesis (Shafir, 1993) and the accentuation hypothesis (Wedell, 1997). We examined the role of task frame by distinguishing these 2 hypotheses and evaluating the information-processing basis of the choices. Experiments conducted online (Experiments 1 and 3) and in-lab (Experiment 4 with eye-tracking technique) revealed a difference between the 2 task frames in the choice data (i.e., the task-framing effect) as a function of the relative attractiveness of the options. Also, this task-framing effect was not influenced by imposed time constraints (Experiments 5 and 6) and was similarly evident with a more direct measure for the option attractiveness (obtained in Experiment 7). Experiment 2, conducted in a lab setting with verbal-protocol requirements, yielded no task-framing effect, suggesting that a requirement to verbalize reasons for choice minimizes accentuation. With this exception, the choice data are in agreement with the accentuation hypothesis, and the combined findings in choice, decision time, task confusion, and eye-tracking data provide evidence of a basis in cognitive effort rather than motivation, as Wedell proposed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Navigating the field of temporally framed care in the Danish home care sector.
Tufte, Pernille; Dahl, Hanne Marlene
2016-01-01
The organisational and temporal framing of elderly care in Europe has changed in the wake of new public management reforms and standardised care services, the strict measurement of time and work schedules have become central aspects of care work. The article investigates the crafting of care in this framing: how care workers approach the services specified in their rotas and navigate between needs, demands and opportunities in the daily performance of duties. Applying feminist theory on time and anthropological theory on social navigation, it examines the practice of home care work in two Danish municipalities. Data are derived predominantly from participant observation. The article identifies two overarching temporal dilemmas in different home care situations: one where process time prevails over clock time and another where the care workers balance the two. Focusing on how care workers respond to these dilemmas in practice, the article identifies various navigation tactics, including leaving time outside, individualised routinisation, working on different paths simultaneously and postponing tasks. By assessing care workers' performance in the temporal framing of work and focusing on care workers' mediation between different time logics, this study provides an in-depth perspective on the broader feminist literature on the dilemmas of care. © 2015 Foundation for the Sociology of Health & Illness.
The Ingenious Theory of Interstellar Trade
NASA Astrophysics Data System (ADS)
Radhakrishnan, Arun; Ganapathy, Rohan M.
This paper extends interplanetary trade theory to an interstellar setting. It is chiefly concerned with the following question: How should interest charges on goods in transit be computed when the goods travel at speeds close to the actual speed of light? This is a problem because the time taken in transit will appear less to an observer travelling with the goods than to a stationary observer. An innovative and ingenious solution is derived from the economic theory, and two useless but TRUE theorems are proved. The interstellar trade would happen in such a way that two time frames must be considered namely that of the stationary observer whose time runs faster compared to the time frame of the observer in transit The interest in a given trade is purely based on the time taken for the debtor to pay the amount, once the goods have been delivered by the seller. But, in case of interstellar trade, the interest to be calculated in between two time frames would lead to the question of which time frame to be considered and moreover, the time taken for the goods to reach the destination is signicantly prolonged compared to the interplanetary trade, which means, even the slightest variations in the interest rate would be magnied. Apart from this, various new factors arise while calculating the interest. The factors include the time value of money, and the risk of variation in demand for goods, the risk of interspace accidents causing loss of the goods and the rate of perish-ability in case of organic goods. The first two factors considered, for which the time frame of the stationary observer is considered and the factors such as the risk of accidents and the rate of perish-ability of the goods are considered based on the time frame of the observer in transit's point of view. The reasons for such considerations and various assumptions on these concepts are dealt in this paper. The theorems that are formulated in this paper would provide the interstellar traders a basic framework on the uniqueness of interstellar trading as opposed to the interplanetary trading. The paper would also tackle problems based on the computation of the perish-ability factor and the risk of variation in demand, as per special relativity. On the whole, a realistic approach based in the current trade policies and accounting standards is given, for a futurist trading spectrum.
Why the Greenwich Meridian Moved
2015-08-01
that are related to the geocentric reference frame introduced by the Bureau International de l’Heure (BIH) in 1984. This BIHTerrestrial System provided...the basis for orientation of subsequent geocentric reference frames, including all realizations of theWorld Geodetic Sys- tem 1984 and the...astronomical time. The coordinates of satellite-navigation receivers are provided in reference frames that are related to the geocentric reference
NASA Astrophysics Data System (ADS)
Seeto, Wen Jun; Lipke, Elizabeth Ann
2016-03-01
Tracking of rolling cells via in vitro experiment is now commonly performed using customized computer programs. In most cases, two critical challenges continue to limit analysis of cell rolling data: long computation times due to the complexity of tracking algorithms and difficulty in accurately correlating a given cell with itself from one frame to the next, which is typically due to errors caused by cells that either come close in proximity to each other or come in contact with each other. In this paper, we have developed a sophisticated, yet simple and highly effective, rolling cell tracking system to address these two critical problems. This optical cell tracking analysis (OCTA) system first employs ImageJ for cell identification in each frame of a cell rolling video. A custom MATLAB code was written to use the geometric and positional information of all cells as the primary parameters for matching each individual cell with itself between consecutive frames and to avoid errors when tracking cells that come within close proximity to one another. Once the cells are matched, rolling velocity can be obtained for further analysis. The use of ImageJ for cell identification eliminates the need for high level MATLAB image processing knowledge. As a result, only fundamental MATLAB syntax is necessary for cell matching. OCTA has been implemented in the tracking of endothelial colony forming cell (ECFC) rolling under shear. The processing time needed to obtain tracked cell data from a 2 min ECFC rolling video recorded at 70 frames per second with a total of over 8000 frames is less than 6 min using a computer with an Intel® Core™ i7 CPU 2.80 GHz (8 CPUs). This cell tracking system benefits cell rolling analysis by substantially reducing the time required for post-acquisition data processing of high frame rate video recordings and preventing tracking errors when individual cells come in close proximity to one another.
Adaptation of hidden Markov models for recognizing speech of reduced frame rate.
Lee, Lee-Min; Jean, Fu-Rong
2013-12-01
The frame rate of the observation sequence in distributed speech recognition applications may be reduced to suit a resource-limited front-end device. In order to use models trained using full-frame-rate data in the recognition of reduced frame-rate (RFR) data, we propose a method for adapting the transition probabilities of hidden Markov models (HMMs) to match the frame rate of the observation. Experiments on the recognition of clean and noisy connected digits are conducted to evaluate the proposed method. Experimental results show that the proposed method can effectively compensate for the frame-rate mismatch between the training and the test data. Using our adapted model to recognize the RFR speech data, one can significantly reduce the computation time and achieve the same level of accuracy as that of a method, which restores the frame rate using data interpolation.
Theory, implementation and applications of nonstationary Gabor frames
Balazs, P.; Dörfler, M.; Jaillet, F.; Holighaus, N.; Velasco, G.
2011-01-01
Signal analysis with classical Gabor frames leads to a fixed time–frequency resolution over the whole time–frequency plane. To overcome the limitations imposed by this rigidity, we propose an extension of Gabor theory that leads to the construction of frames with time–frequency resolution changing over time or frequency. We describe the construction of the resulting nonstationary Gabor frames and give the explicit formula for the canonical dual frame for a particular case, the painless case. We show that wavelet transforms, constant-Q transforms and more general filter banks may be modeled in the framework of nonstationary Gabor frames. Further, we present the results in the finite-dimensional case, which provides a method for implementing the above-mentioned transforms with perfect reconstruction. Finally, we elaborate on two applications of nonstationary Gabor frames in audio signal processing, namely a method for automatic adaptation to transients and an algorithm for an invertible constant-Q transform. PMID:22267893
Serial changes of humor comprehension for four-frame comic Manga: an fMRI study.
Osaka, Mariko; Yaoi, Ken; Minamoto, Takehiro; Osaka, Naoyuki
2014-07-25
Serial changes of humor comprehension evoked by a well organized four-frame comic Manga were investigated by fMRI in each step of humor comprehension. The neural substrates underlying the amusing effects in response to funny and mixed order manga were compared. In accordance with the time course of the four frames, fMRI activations changed serially. Beginning with the second frame (development scene), activation of the temporo-parietal junction (TPJ) was observed, followed by activations in the temporal and frontal areas during viewing of the third frame (turn scene). For the fourth frame (punch line), strong increased activations were confirmed in the medial prefrontal cortex (MPFC) and cerebellum. Interestingly, distinguishable activation differences in the cerebellum between funny and non-funny conditions were also found for the fourth frame. These findings suggest that humor comprehension evokes activation that initiates in the TPJ and expands to the MPFC and cerebellum at the convergence level.
Satia, Jessie A.; Barlow, Jameta; Armstrong-Brown, Janelle; Watters, Joanne L.
2010-01-01
Aims To develop and test cancer prevention messages based on Prospect theory on motivation to improve dietary intake in African American adolescents, and to explore other salient factors that may inform dietary intervention design and implementation in this population. Methods Semi-structured in-person qualitative interviews were conducted with 13 African-American male and female adolescents, 12-16 years, in North Carolina. Prospect theory and message framing were used to guide the design of the four sets of diet-related messages related to cancer prevention: short-term gain-, long-term gain-, short-term loss-, and long-term loss-framed messages. Data were also collected on demographic, behavioral, and psychological factors; usual health behaviors; and preferences for intervention delivery. Results The majority of respondents found the gain-framed, short-term messages most salient for both fruits/vegetables (8 (61.5%)), and fat consumption (7 (53.8%)). For fat consumption only, 2 (15.4%) found the loss-framed, short-term messages pertinent; none found the loss-framed, long-term messages relevant for either dietary variable. All indicated interest in participating in a dietary intervention/education program; most preferred the Internet as a channel for intervention delivery. Participants expressed diverse views regarding knowledge, attitudes, and beliefs regarding healthy eating. Conclusions Researchers conducting dietary interventions and education initiatives and medical professionals who counsel African American adolescents should consider using Prospect Theory as a theoretical framework, should focus on gain-framed short-term messages regarding cancer prevention, and should employ the Internet for data collection and intervention and information delivery. PMID:20142738
Perceiving Event Dynamics and Parsing Hollywood Films
ERIC Educational Resources Information Center
Cutting, James E.; Brunick, Kaitlin L.; Candan, Ayse
2012-01-01
We selected 24 Hollywood movies released from 1940 through 2010 to serve as a film corpus. Eight viewers, three per film, parsed them into events, which are best termed subscenes. While watching a film a second time, viewers scrolled through frames and recorded the frame number where each event began. Viewers agreed about 90% of the time. We then…
42 CFR 405.1016 - Time frames for deciding an appeal before an ALJ.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 2 2011-10-01 2011-10-01 false Time frames for deciding an appeal before an ALJ. 405.1016 Section 405.1016 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH..., Redeterminations, Reconsiderations, and Appeals Under Original Medicare (Part A and Part B) Alj Hearings § 405.1016...
42 CFR 405.1016 - Time frames for deciding an appeal before an ALJ.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Time frames for deciding an appeal before an ALJ. 405.1016 Section 405.1016 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH..., Redeterminations, Reconsiderations, and Appeals Under Original Medicare (Part A and Part B) Alj Hearings § 405.1016...
Speech coding, reconstruction and recognition using acoustics and electromagnetic waves
Holzrichter, J.F.; Ng, L.C.
1998-03-17
The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used for purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching. 35 figs.
Speech coding, reconstruction and recognition using acoustics and electromagnetic waves
Holzrichter, John F.; Ng, Lawrence C.
1998-01-01
The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used for purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching.
Bounce universe from string-inspired Gauss-Bonnet gravity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bamba, Kazuharu; Makarenko, Andrey N.; Myagky, Alexandr N.
2015-04-01
We explore cosmology with a bounce in Gauss-Bonnet gravity where the Gauss-Bonnet invariant couples to a dynamical scalar field. In particular, the potential and and Gauss-Bonnet coupling function of the scalar field are reconstructed so that the cosmological bounce can be realized in the case that the scale factor has hyperbolic and exponential forms. Furthermore, we examine the relation between the bounce in the string (Jordan) and Einstein frames by using the conformal transformation between these conformal frames. It is shown that in general, the property of the bounce point in the string frame changes after the frame is movedmore » to the Einstein frame. Moreover, it is found that at the point in the Einstein frame corresponding to the point of the cosmological bounce in the string frame, the second derivative of the scale factor has an extreme value. In addition, it is demonstrated that at the time of the cosmological bounce in the Einstein frame, there is the Gauss-Bonnet coupling function of the scalar field, although it does not exist in the string frame.« less
Parallel Key Frame Extraction for Surveillance Video Service in a Smart City.
Zheng, Ran; Yao, Chuanwei; Jin, Hai; Zhu, Lei; Zhang, Qin; Deng, Wei
2015-01-01
Surveillance video service (SVS) is one of the most important services provided in a smart city. It is very important for the utilization of SVS to provide design efficient surveillance video analysis techniques. Key frame extraction is a simple yet effective technique to achieve this goal. In surveillance video applications, key frames are typically used to summarize important video content. It is very important and essential to extract key frames accurately and efficiently. A novel approach is proposed to extract key frames from traffic surveillance videos based on GPU (graphics processing units) to ensure high efficiency and accuracy. For the determination of key frames, motion is a more salient feature in presenting actions or events, especially in surveillance videos. The motion feature is extracted in GPU to reduce running time. It is also smoothed to reduce noise, and the frames with local maxima of motion information are selected as the final key frames. The experimental results show that this approach can extract key frames more accurately and efficiently compared with several other methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rashkin, Hannah J.; Bell, Eric B.; Choi, Yejin
People around the globe respond to major real world events through social media. To study targeted public sentiments across many languages and geographic locations, we introduce multilingual connotation frames: an extension from English connotation frames of Rashkin et al. (2016) with 10 additional European languages, focusing on the implied sentiments among event participants engaged in a frame. As a case study, we present large scale analysis on targeted public sentiments using 1.2 million multilingual connotation frames extracted from Twitter. We rely on connotation frames to build models to forecast country-specific connotation dynamics – perspective change over time towards salient entitiesmore » and events. Our results demonstrate that connotation dynamics can be accurately predicted up to half a week in advance.« less
de Bruijn, Gert-Jan; Budding, Jeen
2016-08-01
Message framing is a persuasive strategy that has seen mixed evidence for promoting fruit intake intentions, potentially because framed messages for fruit intake have not (a) explicitly compared short-term consequences versus long-term consequences, (b) considered individual-level differences in time perspective, and (c) used alternative measures of fruit intake intentions. In the present online study, the effects of persuasive messages created from temporal context (short term vs. long term) and message frame (gain framed vs. loss framed) were investigated on fruit intake intentions and resolve among a sample of Dutch adults who were categorized as either present oriented or future oriented. For intention and resolve, results showed a significant Type of Frame × Type of Temporal Context interaction, such that gain-framed messages were more persuasive when combined with long-term consequences and loss-framed messages were more persuasive when combined with short-term consequences. The effect sizes for these differences were similar for resolve and intention, but only differences for intentions were significant. No other effects were found. These results demonstrate that message framing theory may usefully consider the inclusion of temporal context of outcomes and alternative motivation measures to maximize their persuasive effects.
Anderson, Peter; Berridge, Virginia; Conrod, Patricia; Dudley, Robert; Hellman, Matilda; Lachenmeier, Dirk; Lingford-Hughes, Anne; Miller, David; Rehm, Jürgen; Room, Robin; Schmidt, Laura; Sullivan, Roger; Ysa, Tamyko; Gual, Antoni
2017-01-01
In 2013, illegal drug use was responsible for 1.8% of years of life lost in the European Union, alcohol was responsible for 8.2% and tobacco for 18.2%, imposing economic burdens in excess of 2.5% of GDP. No single European country has optimal governance structures for reducing the harm done by nicotine, illegal drugs and alcohol, and existing ones are poorly designed, fragmented, and sometimes cause harm. Reporting the main science and policy conclusions of a transdisciplinary five-year analysis of the place of addictions in Europe, researchers from 67 scientific institutions addressed these problems by reframing an understanding of addictions. A new paradigm needs to account for evolutionary evidence which suggests that humans are biologically predisposed to seek out drugs, and that, today, individuals face availability of high drug doses, consequently increasing the risk of harm. New definitions need to acknowledge that the defining element of addictive drugs is 'heavy use over time', a concept that could replace the diagnostic artefact captured by the clinical term 'substance use disorder', thus opening the door for new substances to be considered such as sugar. Tools of quantitative risk assessment that recognize drugs as toxins could be further deployed to assess regulatory approaches to reducing harm. Re-designed governance of drugs requires embedding policy within a comprehensive societal well-being frame that encompasses a range of domains of well-being, including quality of life, material living conditions and sustainability over time; such a frame adds arguments to the inappropriateness of policies that criminalize individuals for using drugs and that continue to categorize certain drugs as illegal. A health footprint, modelled on the carbon footprint, and using quantitative measures such as years of life lost due to death or disability, could serve as the accountability tool that apportions responsibility for who and what causes drug-related harm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lauzier, Pascal Theriault; Tang Jie; Speidel, Michael A.
Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise andmore » streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.« less
Lauzier, Pascal Thériault; Tang, Jie; Speidel, Michael A.; Chen, Guang-Hong
2012-01-01
Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI. PMID:22830741
Flexible nuclear medicine camera and method of using
Dilmanian, F.A.; Packer, S.; Slatkin, D.N.
1996-12-10
A nuclear medicine camera and method of use photographically record radioactive decay particles emitted from a source, for example a small, previously undetectable breast cancer, inside a patient. The camera includes a flexible frame containing a window, a photographic film, and a scintillation screen, with or without a gamma-ray collimator. The frame flexes for following the contour of the examination site on the patient, with the window being disposed in substantially abutting contact with the skin of the patient for reducing the distance between the film and the radiation source inside the patient. The frame is removably affixed to the patient at the examination site for allowing the patient mobility to wear the frame for a predetermined exposure time period. The exposure time may be several days for obtaining early qualitative detection of small malignant neoplasms. 11 figs.
The Effective Fracture Toughness of Aluminum at Rapid Heating Rates.
1987-12-01
Stress Versus Time Relation During Test Under HWdraulic (Tinius-Olsen) Loading Device 32 11. Creep Rupture Tester ( SATEC ) Drawing ...... 33 12. SEN...1B7 Machine Corp Creep Frame SATEC C C-3053-P 12,000 Load Cell MTS 661.20A 271 5500 lb .02% Load Cell Interface 1220BF 34279B 25000 lb 1.6% Extenso- MIS... SATEC creep frame. A drawing of the creep frame can be seen in Figure 11. The samples were placed in the frame and the dead weight load was applied
Passive optical coherence elastography using a time-reversal approach (Conference Presentation)
NASA Astrophysics Data System (ADS)
Nguyen, Thu-Mai; Zorgani, Ali; Fink, Mathias; Catheline, Stefan; Boccara, A. Claude
2017-02-01
Background and motivation - Conventional Optical Coherence Elastography (OCE) methods consist in launching controlled shear waves in tissues, and measuring their propagation speed using an ultrafast imaging system. However, the use of external shear sources limits transfer to clinical practice, especially for ophthalmic applications. Here, we propose a totally passive OCE method for ocular tissues based on time-reversal of the natural vibrations. Methods - Experiments were first conducted on a tissue-mimicking phantom containing a stiff inclusion. Pulsatile motions were reproduced by stimulating the phantom surface with two piezoelectric actuators excited asynchronously at low frequencies (50-500 Hz). The resulting random displacements were tracked at 190 frames/sec using spectral-domain optical coherence tomography (SD-OCT), with a 10x5µm² resolution over a 3x2mm² field-of-view (lateral x depth). The shear wavefield was numerically refocused (i.e. time-reversed) at each pixel using noise-correlation algorithms. The focal spot size yields the shear wavelength. Results were validated by comparison with shear wave speed measurements obtained from conventional active OCE. In vivo tests were then conducted on anesthetized rats. Results - The stiff inclusion of the phantom was delineated on the wavelength map with a wavelength ratio between the inclusion and the background (1.6) consistent with the speed ratio (1.7). This validates the wavelength measurements. In vivo, natural shear waves were detected in the eye and wavelength maps of the anterior segment showed a clear elastic contrast between the cornea, the sclera and the iris. Conclusion - We validated the time-reversal approach for passive elastography using SD-OCT imaging at low frame-rate. This method could accelerate the clinical transfer of ocular elastography.
Enhancement Strategies for Frame-To Uas Stereo Visual Odometry
NASA Astrophysics Data System (ADS)
Kersten, J.; Rodehorst, V.
2016-06-01
Autonomous navigation of indoor unmanned aircraft systems (UAS) requires accurate pose estimations usually obtained from indirect measurements. Navigation based on inertial measurement units (IMU) is known to be affected by high drift rates. The incorporation of cameras provides complementary information due to the different underlying measurement principle. The scale ambiguity problem for monocular cameras is avoided when a light-weight stereo camera setup is used. However, also frame-to-frame stereo visual odometry (VO) approaches are known to accumulate pose estimation errors over time. Several valuable real-time capable techniques for outlier detection and drift reduction in frame-to-frame VO, for example robust relative orientation estimation using random sample consensus (RANSAC) and bundle adjustment, are available. This study addresses the problem of choosing appropriate VO components. We propose a frame-to-frame stereo VO method based on carefully selected components and parameters. This method is evaluated regarding the impact and value of different outlier detection and drift-reduction strategies, for example keyframe selection and sparse bundle adjustment (SBA), using reference benchmark data as well as own real stereo data. The experimental results demonstrate that our VO method is able to estimate quite accurate trajectories. Feature bucketing and keyframe selection are simple but effective strategies which further improve the VO results. Furthermore, introducing the stereo baseline constraint in pose graph optimization (PGO) leads to significant improvements.
3-D ultrasound volume reconstruction using the direct frame interpolation method.
Scheipers, Ulrich; Koptenko, Sergei; Remlinger, Rachel; Falco, Tony; Lachaine, Martin
2010-11-01
A new method for 3-D ultrasound volume reconstruction using tracked freehand 3-D ultrasound is proposed. The method is based on solving the forward volume reconstruction problem using direct interpolation of high-resolution ultrasound B-mode image frames. A series of ultrasound B-mode image frames (an image series) is acquired using the freehand scanning technique and position sensing via optical tracking equipment. The proposed algorithm creates additional intermediate image frames by directly interpolating between two or more adjacent image frames of the original image series. The target volume is filled using the original frames in combination with the additionally constructed frames. Compared with conventional volume reconstruction methods, no additional filling of empty voxels or holes within the volume is required, because the whole extent of the volume is defined by the arrangement of the original and the additionally constructed B-mode image frames. The proposed direct frame interpolation (DFI) method was tested on two different data sets acquired while scanning the head and neck region of different patients. The first data set consisted of eight B-mode 2-D frame sets acquired under optimal laboratory conditions. The second data set consisted of 73 image series acquired during a clinical study. Sample volumes were reconstructed for all 81 image series using the proposed DFI method with four different interpolation orders, as well as with the pixel nearest-neighbor method using three different interpolation neighborhoods. In addition, volumes based on a reduced number of image frames were reconstructed for comparison of the different methods' accuracy and robustness in reconstructing image data that lies between the original image frames. The DFI method is based on a forward approach making use of a priori information about the position and shape of the B-mode image frames (e.g., masking information) to optimize the reconstruction procedure and to reduce computation times and memory requirements. The method is straightforward, independent of additional input or parameters, and uses the high-resolution B-mode image frames instead of usually lower-resolution voxel information for interpolation. The DFI method can be considered as a valuable alternative to conventional 3-D ultrasound reconstruction methods based on pixel or voxel nearest-neighbor approaches, offering better quality and competitive reconstruction time.
NASA Astrophysics Data System (ADS)
Yang, Victor X.; Gordon, M. L.; Qi, B.; Yue, E. Seng; Tang, S.; Bisland, Stuart K.; Pekar, J.; Lo, S.; Marcon, Norman E.; Wilson, B.; Vitkin, Alex
2003-07-01
Background: Currently clinical Doppler ultrasound cannot detect microvascular blood flow and it is difficult to provide depth discrimination using laser Doppler flowmetry. Doppler optical coherence tomography (DOCT) is a novel technique for noninvasive subsurface imaging of microcirculation and tissue structure. Aims: To design handheld and catheter-based DOCT probes for clinical cutaneous and endoscopic imaging. To develop signal processing techniques for real-time detection and quantification of microvascular blood flow. Methods: A DOCT system, with interchangeable cutaneous and catheter probes, was developed. The axial spatial resolution was 10 μm, and the velocity resolution was 20 μm/s, using a 1300 nm broadband infrared light. The system achieved real-time imaging with frame rates up to 32 Hz at 512 x 256 pixels per frame. We used the system to detect microcirculation in human skin and rat esophagus, and to monitor microvascular responses to photodynamic therapy (PDT) in a rat tumor model. Results: We present experimental results from in vivo DOCT imaging of microcirculation in human skin arterio-venous malformations (AVM), normal rat esophagus, and a rat gliosarcoma PDT model. In the PDT model, we followed microvascular responses to PDT and observed differences in the microcirculation during and after therapy, which can have important implications for PDT dosimetry and treatment optimization. Conclusions: To our knowledge, this is the first demonstration of endoscopic catheter-based DOCT detection of microcirculation in vivo. In addition, AVM can be detected using handheld cutaneous DOCT probes under clinical settings. DOCT may serve as a real-time monitoring tool for PDT dosimetry, especially for vascular targeting photosensitizers.
Impact of Submesoscale Processes on Dynamics of Phytoplankton Filaments
2015-02-12
submesoscale processes on the formation of chlorophyll a filaments during late springearlier summer, and late summer time frames. We show that during...the late summer time frame, ASC leads to the development of filaments with high values of chlorophyll a concentration along the edge of the cold jet...in contrast to the earlier summer time, when the ASC mixes phytoplankton much deeper to the area below of the euphotic depth, and chlorophyll a
Sequential detection of web defects
Eichel, Paul H.; Sleefe, Gerard E.; Stalker, K. Terry; Yee, Amy A.
2001-01-01
A system for detecting defects on a moving web having a sequential series of identical frames uses an imaging device to form a real-time camera image of a frame and a comparitor to comparing elements of the camera image with corresponding elements of an image of an exemplar frame. The comparitor provides an acceptable indication if the pair of elements are determined to be statistically identical; and a defective indication if the pair of elements are determined to be statistically not identical. If the pair of elements is neither acceptable nor defective, the comparitor recursively compares the element of said exemplar frame with corresponding elements of other frames on said web until one of the acceptable or defective indications occur.
Software Process Automation: Interviews, Survey, and Workshop Results.
1997-10-01
International Business Machines Coproration Foundation is a pending trademark of Foundation Software , Inc. FrameMaker is a registered trademark of Adobe, Inc...amount of technology Integration of technologies, con- flicting points of view between adopting org. and consultants E CM FrameMaker Labor/resource...Weaver FrameMaker , CM System Integration of CM tool L InConcert Cadre, AutoPlan, DBStar Ineffective process integration, poor training, time
Framing and visual type: Effect on future Zika vaccine uptake intent
Guidry, Jeanine P.D.; Carlyle, Kellie E.; LaRose, Jessica G.; Perrin, Paul; Ryan, Mark; Messner, Marcus; Adams, Jay
2018-01-01
Introduction The Zika virus is associated with the birth defect microcephaly, and while a vaccine was not available in early- 2017, several were under development. This study’s purpose was to identify effective communication strategies to promote uptake of a new vaccine, particularly among women of reproductive age. Design and methods In order to study the effects of Zika message framing (gain vs. loss) and visual type (photo vs. infographic) on future Zika vaccine uptake intent, a 2×2 between-subjects experiment was performed via an online survey in 2017 among 339 U.S. women of reproductive age (18-49 years). Participants were exposed to one of four messages, all resembling Instagram posts: gain-framed vs. loss-framed infographic, and gain-framed vs. loss-framed photo. These messages were followed by questions about Zika vaccine uptake intent as well as intermediate psychosocial variables that could lead to intent. Results There was no interaction between framing and visual type (P=0.116), and there was no effect for framing (P=0.185) or visual type (P=0.724) on future Zika vaccine uptake intent, which is likely indicative of insufficient dosage of the intervention. However, when focusing on intermediate psychosocial constructs that are known to influence behavior and intent, gain-framed messages were more effective in increasing subjective norms (P=0.005) as related to a future Zika vaccine, as well as perceived benefits (P=0.016) and self-efficacy (P=0.032). Conclusions Gain-framed messages seem to be more effective than loss-framed messages to increase several constructs that could, in turn, affect future Zika vaccine uptake intent. This is a novel finding since, traditionally, loss-framed messages are considered more beneficial in promoting vaccine-related health behaviors. Significance for public healthThe study described in this paper is significant for the field of public health for several reasons: It takes a proactive approach in studying messaging focused on the Zika vaccine before that vaccine is available, allowing for quick implementation of its limited results. In addition, this study centers on messaging in the form of realistic images consistent with those that could be posted on Instagram, thereby focusing on a relatively new yet immensely popular communications platform that few are focusing on presently. PMID:29780762
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mao, W; Hrycushko, B; Yan, Y
Purpose: Traditional external beam radiotherapy for cervical cancer requires setup by external skin marks. In order to improve treatment accuracy and reduce planning margin for more conformal therapy, it is essential to monitor tumor positions interfractionally and intrafractionally. We demonstrate feasibility of monitoring cervical tumor motion online using EPID imaging from Beam’s Eye View. Methods: Prior to treatment, 1∼2 cylindrical radio opaque markers were implanted into inferior aspect of cervix tumor. During external beam treatments on a Varian 2100C by 4-field 3D plans, treatment beam images were acquired continuously by an EPID. A Matlab program was developed to locate internalmore » markers on MV images. Based on 2D marker positions obtained from different treatment fields, their 3D positions were estimated for every treatment fraction. Results: There were 398 images acquired during different treatment fractions of three cervical cancer patients. Markers were successfully located on every frame of image at an analysis speed of about 1 second per frame. Intrafraction motions were evaluated by comparing marker positions relative to the position on the first frame of image. The maximum intrafraction motion of the markers was 1.6 mm. Interfraction motions were evaluated by comparing 3D marker positions at different treatment fractions. The maximum interfraction motion was up to 10 mm. Careful comparison found that this is due to patient positioning since the bony structures shifted with the markers. Conclusion: This method provides a cost-free and simple solution for online tumor tracking for cervical cancer treatment since it is feasible to acquire and export EPID images with fast analysis in real time. This method does not need any extra equipment or deliver extra dose to patients. The online tumor motion information will be very useful to reduce planning margins and improve treatment accuracy, which is particularly important for SBRT treatment with long delivery time.« less
Boryshpolets, S; Kowalski, R K; Dietrich, G J; Dzyuba, B; Ciereszko, A
2013-10-15
In this study, we examined different computer-assisted sperm analysis (CASA) systems (CRISMAS, Hobson Sperm Tracker, and Image J CASA) on the exact same video recordings to evaluate the differences in sperm motility parameters related to the specific CASA used. To cover a wide range of sperm motility parameters, we chose 12-second video recordings at 25 and 50 Hz frame rates after sperm motility activation using three taxonomically distinct fish species (sterlet: Acipenser ruthenus L.; common carp: Cyprinus carpio L.; and rainbow trout: Oncorhynchus mykiss Walbaum) that are characterized by essential differences in sperm behavior during motility. Systematically higher values of velocity and beat cross frequency (BCF) were observed in video recordings obtained at 50 Hz frame frequency compared with 25 Hz for all three systems. Motility parameters were affected by the CASA and species used for analyses. Image J and CRISMAS calculated higher curvilinear velocity (VCL) values for rainbow trout and common carp at 25 Hz frequency compared with the Hobson Sperm Tracker, whereas at 50 Hz, a significant difference was observed only for rainbow trout sperm recordings. No significant difference was observed between the CASA systems for sterlet sperm motility at 25 and 50 Hz. Additional analysis of 1-second segments taken at three time points (1, 6, and 12 seconds of the recording) revealed a dramatic decrease in common carp and rainbow trout sperm speed. The motility parameters of sterlet spermatozoa did not change significantly during the 12-second motility period and should be considered as a suitable model for longer motility analyses. Our results indicated that the CASA used can affect motility results even when the same motility recordings are used. These results could be critically altered by the recording quality, time of analysis, and frame rate of camera, and could result in erroneous conclusions. Copyright © 2013 Elsevier Inc. All rights reserved.
AN ANALYSIS OF SYSTEMS FOR FEEDING HOT MEALS TO THE ARMY IN THE FIELD DURING 1975-1990 TIME FRAME.
An analysis was conducted of a large number of potential systems for feeding hot meals to the Army in the field during the 1975-1990 time frame...system of company level feeding . An analysis of alternative mixed systems (company level and higher) is also made indicating greater potential for food
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... requirements of Section 12(d) of the National Technology Transfer and Advancement Act of 1995 (15 U.S.C. 272..., (212) 637-3381. SUPPLEMENTARY INFORMATION: Table of Contents I. What is the history and time frame for... Executive Order Reviews I. What is the history and time frame for State Implementation Plan (SIP...
Stern Frame and Hawsepipe Construction Technology
1978-01-01
to the classificationsocieties regarding possible changes in the rules governing stern frame and hawsepipe designs were also considered. In the first...which were most representativeof the ships being constructedor contemplatedfor constructionin U.S. shipyards,and comparing them from the standpoint of...equipmentneeded in the manufacturing process. Time: Length of time needed to completeunits on a comparative 1.3 Summary of Results The data obtained
Protein crystal structure from non-oriented, single-axis sparse X-ray data
Wierman, Jennifer L.; Lan, Ti-Yen; Tate, Mark W.; ...
2016-01-01
X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that aremore » kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using theEMCalgorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using theEMCalgorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of theEMCalgorithm even in cases where the data are sparse.« less
Protein crystal structure from non-oriented, single-axis sparse X-ray data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wierman, Jennifer L.; Lan, Ti-Yen; Tate, Mark W.
X-ray free-electron lasers (XFELs) have inspired the development of serial femtosecond crystallography (SFX) as a method to solve the structure of proteins. SFX datasets are collected from a sequence of protein microcrystals injected across ultrashort X-ray pulses. The idea behind SFX is that diffraction from the intense, ultrashort X-ray pulses leaves the crystal before the crystal is obliterated by the effects of the X-ray pulse. The success of SFX at XFELs has catalyzed interest in analogous experiments at synchrotron-radiation (SR) sources, where data are collected from many small crystals and the ultrashort pulses are replaced by exposure times that aremore » kept short enough to avoid significant crystal damage. The diffraction signal from each short exposure is so `sparse' in recorded photons that the process of recording the crystal intensity is itself a reconstruction problem. Using theEMCalgorithm, a successful reconstruction is demonstrated here in a sparsity regime where there are no Bragg peaks that conventionally would serve to determine the orientation of the crystal in each exposure. In this proof-of-principle experiment, a hen egg-white lysozyme (HEWL) crystal rotating about a single axis was illuminated by an X-ray beam from an X-ray generator to simulate the diffraction patterns of microcrystals from synchrotron radiation. Millions of these sparse frames, typically containing only ~200 photons per frame, were recorded using a fast-framing detector. It is shown that reconstruction of three-dimensional diffraction intensity is possible using theEMCalgorithm, even with these extremely sparse frames and without knowledge of the rotation angle. Further, the reconstructed intensity can be phased and refined to solve the protein structure using traditional crystallographic software. In conclusion, this suggests that synchrotron-based serial crystallography of micrometre-sized crystals can be practical with the aid of theEMCalgorithm even in cases where the data are sparse.« less
TreeMAC: Localized TDMA MAC protocol for real-time high-data-rate sensor networks
Song, W.-Z.; Huang, R.; Shirazi, B.; Husent, R.L.
2009-01-01
Earlier sensor network MAC protocols focus on energy conservation in low-duty cycle applications, while some recent applications involve real-time high-data-rate signals. This motivates us to design an innovative localized TDMA MAC protocol to achieve high throughput and low congestion in data collection sensor networks, besides energy conservation. TreeMAC divides a time cycle into frames and frame into slots. Parent determines children's frame assigmnent based on their relative bandwidth demand, and each node calculates its own slot assignment based on its hop-count to the sink. This innovative 2-dimensional frame-slot assignment algorithm has the following nice theory properties. Firstly, given any node, at any time slot, there is at most one active sender in its neighborhood (includ ing itself). Secondly, the packet scheduling with TreelMAC is bufferless, which therefore minimizes the probability of network congestion. Thirdly, the data throughput to gateway is at least 1/3 of the optimum assuming reliable links. Our experiments on a 24 node test bed demonstrate that TreeMAC protocol significantly improves network throughput and energy efficiency, by comparing to the TinyOS's default CSMA MAC protocol and a recent TDMA MAC protocol Funneling-MAC[8]. ?? 2009 IEEE.
Reduction of capsule endoscopy reading times by unsupervised image mining.
Iakovidis, D K; Tsevas, S; Polydorou, A
2010-09-01
The screening of the small intestine has become painless and easy with wireless capsule endoscopy (WCE) that is a revolutionary, relatively non-invasive imaging technique performed by a wireless swallowable endoscopic capsule transmitting thousands of video frames per examination. The average time required for the visual inspection of a full 8-h WCE video ranges from 45 to 120min, depending on the experience of the examiner. In this paper, we propose a novel approach to WCE reading time reduction by unsupervised mining of video frames. The proposed methodology is based on a data reduction algorithm which is applied according to a novel scheme for the extraction of representative video frames from a full length WCE video. It can be used either as a video summarization or as a video bookmarking tool, providing the comparative advantage of being general, unbounded by the finiteness of a training set. The number of frames extracted is controlled by a parameter that can be tuned automatically. Comprehensive experiments on real WCE videos indicate that a significant reduction in the reading times is feasible. In the case of the WCE videos used this reduction reached 85% without any loss of abnormalities.
NASA Astrophysics Data System (ADS)
Li, Jia; Tian, Yonghong; Gao, Wen
2008-01-01
In recent years, the amount of streaming video has grown rapidly on the Web. Often, retrieving these streaming videos offers the challenge of indexing and analyzing the media in real time because the streams must be treated as effectively infinite in length, thus precluding offline processing. Generally speaking, captions are important semantic clues for video indexing and retrieval. However, existing caption detection methods often have difficulties to make real-time detection for streaming video, and few of them concern on the differentiation of captions from scene texts and scrolling texts. In general, these texts have different roles in streaming video retrieval. To overcome these difficulties, this paper proposes a novel approach which explores the inter-frame correlation analysis and wavelet-domain modeling for real-time caption detection in streaming video. In our approach, the inter-frame correlation information is used to distinguish caption texts from scene texts and scrolling texts. Moreover, wavelet-domain Generalized Gaussian Models (GGMs) are utilized to automatically remove non-text regions from each frame and only keep caption regions for further processing. Experiment results show that our approach is able to offer real-time caption detection with high recall and low false alarm rate, and also can effectively discern caption texts from the other texts even in low resolutions.
Lattanzi, Riccardo; Zhang, Bei; Knoll, Florian; Assländer, Jakob; Cloos, Martijn A
2018-06-01
Magnetic Resonance Fingerprinting reconstructions can become computationally intractable with multiple transmit channels, if the B 1 + phases are included in the dictionary. We describe a general method that allows to omit the transmit phases. We show that this enables straightforward implementation of dictionary compression to further reduce the problem dimensionality. We merged the raw data of each RF source into a single k-space dataset, extracted the transceiver phases from the corresponding reconstructed images and used them to unwind the phase in each time frame. All phase-unwound time frames were combined in a single set before performing SVD-based compression. We conducted synthetic, phantom and in-vivo experiments to demonstrate the feasibility of SVD-based compression in the case of two-channel transmission. Unwinding the phases before SVD-based compression yielded artifact-free parameter maps. For fully sampled acquisitions, parameters were accurate with as few as 6 compressed time frames. SVD-based compression performed well in-vivo with highly under-sampled acquisitions using 16 compressed time frames, which reduced reconstruction time from 750 to 25min. Our method reduces the dimensions of the dictionary atoms and enables to implement any fingerprint compression strategy in the case of multiple transmit channels. Copyright © 2018 Elsevier Inc. All rights reserved.
Initial Demonstration of 9-MHz Framing Camera Rates on the FAST UV Drive Laser Pulse Trains
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lumpkin, A. H.; Edstrom Jr., D.; Ruan, J.
2016-10-09
We report the configuration of a Hamamatsu C5680 streak camera as a framing camera to record transverse spatial information of green-component laser micropulses at 3- and 9-MHz rates for the first time. The latter is near the time scale of the ~7.5-MHz revolution frequency of the Integrable Optics Test Accelerator (IOTA) ring and its expected synchroton radiation source temporal structure. The 2-D images are recorded with a Gig-E readout CCD camera. We also report a first proof of principle with an OTR source using the linac streak camera in a semi-framing mode.
2013-01-01
Background The term “reproductive, maternal, newborn, and child health (RMNCH)” describes an integrated continuum of health states which is central to Millennium Development Goals 4 and 5. While the burden of mortality and morbidity associated with RMNCH is well known, knowledge is still limited about the economic burden of RMNCH. Concrete evidence of cost of illness (COI) of RMNCH may help policy makers in supporting investment in RMNCH. Methods A systematic literature search of COI studies was performed in electronic databases. The time frame for the analysis was January 1990 – April 2011. The databases checked were Medline (Pubmed), Embase and ECONbase, EconLit, the Cumulative Index to Nursing and Allied Health (CINAHL), the National Bureau of Economic Research, the Latin American and Caribbean Literature on Health Sciences Database (LILACS), and Popline. Furthermore, we searched working papers and reference lists of selected articles. Results All the studies investigated address particular complications and issues of RMNCH, e.g., preterm birth, non-exclusive breastfeeding, and sexually transmitted diseases (STDs), but not RMNCH as an entire continuum. Most of the studies were conducted in high income countries, with limited data on low and middle income countries. The burden of disease is very high even for single complications. For example, the disease burden related to non-exclusive breastfeeding was given as 14.39 billion international dollars (ID) (2012, purchasing power parity) per year in the USA. Methodological differences in study design, costing approach, perspective of analysis, and time frame make it difficult to compare different studies. Conclusion The continuum of RMNCH covers a large portion of the lifespan from birth through the reproductive age. From a methodological perspective, an ideal COI study would clearly describe the perspective of analysis and, hence, the cost items (direct or indirect), cost collection procedure, discounting, quality of data, time frame of analysis, related comorbidities, and robust sensitivity analysis for all the assumptions. Further research is needed to measure the economic impact of RMNCH, including identification of the most cost-effective policy and interventions for prevention, reduction, and elimination of the complications of RMNCH. PMID:24229450
On ethics and the earthquake resistant interior design of buildings.
Hurol, Yonca
2014-03-01
The most common tectonic quality of modern structures, such as frame systems, is their flexibility; they are open for change. Although this characteristic is a big advantage in comparison to the inflexible masonry structures of the past, it might also create some serious problems, such as e.g. the lack of safety in the event of an earthquake, if the flexibility is not used consciously by architects and interior designers. This article attempts to define and establish some rules for the interior design of buildings with reinforced concrete frame systems. The rules for making subtractions from these structures and extending them by making additions to them are contained within this article. The main objective of this article is to derive some ethical values from these rules. Thus, the conclusion of the article focuses on the derivation of some ethical values for achieving earthquake resistant interior design of buildings with reinforced concrete frame systems.
Transverse Momentum Dependence of J/psi Polarization at Midrapidity in p+p Collisions at s = 200 GeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adare, A.; Awes, Terry C; Cianciolo, Vince
We report the measurement of the transverse momentum dependence of inclusive J/{psi} polarization in p+p collisions at {radical}s = 200 GeV performed by the PHENIX Experiment at the Relativistic Heavy Ion Collider. The J/{psi} polarization is studied in the helicity, Gottfried-Jackson, and Collins-Soper frames for p{sub T} < 5 GeV/c and |y| < 0.35. The polarization in the helicity and Gottfried-Jackson frames is consistent with zero for all transverse momenta, with a slight (1.8 sigma) trend towards longitudinal polarization for transverse momenta above 2 GeV/c. No conclusion is allowed due to the limited acceptance in the Collins-Soper frame and themore » uncertainties of the current data. The results are compared to observations for other collision systems and center of mass energies and to different quarkonia production models.« less
Transverse momentum dependence of J/ψ polarization at midrapidity in p+p collisions at s=200GeV
NASA Astrophysics Data System (ADS)
Adare, A.; Afanasiev, S.; Aidala, C.; Ajitanand, N. N.; Akiba, Y.; Al-Bataineh, H.; Alexander, J.; Aoki, K.; Aphecetche, L.; Asai, J.; Atomssa, E. T.; Averbeck, R.; Awes, T. C.; Azmoun, B.; Babintsev, V.; Bai, M.; Baksay, G.; Baksay, L.; Baldisseri, A.; Barish, K. N.; Barnes, P. D.; Bassalleck, B.; Basye, A. T.; Bathe, S.; Batsouli, S.; Baublis, V.; Baumann, C.; Bazilevsky, A.; Belikov, S.; Bennett, R.; Berdnikov, A.; Berdnikov, Y.; Bickley, A. A.; Boissevain, J. G.; Borel, H.; Boyle, K.; Brooks, M. L.; Buesching, H.; Bumazhnov, V.; Bunce, G.; Butsyk, S.; Camacho, C. M.; Campbell, S.; Chang, B. S.; Chang, W. C.; Charvet, J.-L.; Chernichenko, S.; Chi, C. Y.; Chiu, M.; Choi, I. J.; Choudhury, R. K.; Chujo, T.; Chung, P.; Churyn, A.; Cianciolo, V.; Citron, Z.; Cole, B. A.; Conesa Del Valle, Z.; Constantin, P.; Csanád, M.; Csörgö, T.; Dahms, T.; Dairaku, S.; Das, K.; David, G.; Denisov, A.; D'Enterria, D.; Deshpande, A.; Desmond, E. J.; Dietzsch, O.; Dion, A.; Donadelli, M.; Drapier, O.; Drees, A.; Drees, K. A.; Dubey, A. K.; Durum, A.; Dutta, D.; Dzhordzhadze, V.; Efremenko, Y. V.; Ellinghaus, F.; Engelmore, T.; Enokizono, A.; En'Yo, H.; Esumi, S.; Eyser, K. O.; Fadem, B.; Fields, D. E.; Finger, M., Jr.; Finger, M.; Fleuret, F.; Fokin, S. L.; Fraenkel, Z.; Frantz, J. E.; Franz, A.; Frawley, A. D.; Fujiwara, K.; Fukao, Y.; Fusayasu, T.; Garishvili, I.; Glenn, A.; Gong, H.; Gonin, M.; Gosset, J.; Goto, Y.; Granier de Cassagnac, R.; Grau, N.; Greene, S. V.; Grosse Perdekamp, M.; Gunji, T.; Gustafsson, H.-Å.; Hadj Henni, A.; Haggerty, J. S.; Hamagaki, H.; Han, R.; Hartouni, E. P.; Haruna, K.; Haslum, E.; Hayano, R.; Heffner, M.; Hemmick, T. K.; Hester, T.; He, X.; Hill, J. C.; Hohlmann, M.; Holzmann, W.; Homma, K.; Hong, B.; Horaguchi, T.; Hornback, D.; Huang, S.; Ichihara, T.; Ichimiya, R.; Ikeda, Y.; Imai, K.; Imrek, J.; Inaba, M.; Isenhower, D.; Ishihara, M.; Isobe, T.; Issah, M.; Isupov, A.; Ivanischev, D.; Jacak, B. V.; Jia, J.; Jin, J.; Johnson, B. M.; Joo, K. S.; Jouan, D.; Kajihara, F.; Kametani, S.; Kamihara, N.; Kamin, J.; Kang, J. H.; Kapustinsky, J.; Kawall, D.; Kazantsev, A. V.; Kempel, T.; Khanzadeev, A.; Kijima, K. M.; Kikuchi, J.; Kim, B. I.; Kim, D. H.; Kim, D. J.; Kim, E.; Kim, S. H.; Kinney, E.; Kiriluk, K.; Kiss, A.; Kistenev, E.; Klay, J.; Klein-Boesing, C.; Kochenda, L.; Komkov, B.; Konno, M.; Koster, J.; Kozlov, A.; Král, A.; Kravitz, A.; Kunde, G. J.; Kurita, K.; Kurosawa, M.; Kweon, M. J.; Kwon, Y.; Kyle, G. S.; Lacey, R.; Lai, Y. S.; Lajoie, J. G.; Layton, D.; Lebedev, A.; Lee, D. M.; Lee, K. B.; Lee, T.; Leitch, M. J.; Leite, M. A. L.; Lenzi, B.; Liebing, P.; Liška, T.; Litvinenko, A.; Liu, H.; Liu, M. X.; Li, X.; Love, B.; Lynch, D.; Maguire, C. F.; Makdisi, Y. I.; Malakhov, A.; Malik, M. D.; Manko, V. I.; Mannel, E.; Mao, Y.; Mašek, L.; Masui, H.; Matathias, F.; McCumber, M.; McGaughey, P. L.; Means, N.; Meredith, B.; Miake, Y.; Mikeš, P.; Miki, K.; Milov, A.; Mishra, M.; Mitchell, J. T.; Mohanty, A. K.; Morino, Y.; Morreale, A.; Morrison, D. P.; Moukhanova, T. V.; Mukhopadhyay, D.; Murata, J.; Nagamiya, S.; Nagle, J. L.; Naglis, M.; Nagy, M. I.; Nakagawa, I.; Nakamiya, Y.; Nakamura, T.; Nakano, K.; Newby, J.; Nguyen, M.; Niita, T.; Nouicer, R.; Nyanin, A. S.; O'Brien, E.; Oda, S. X.; Ogilvie, C. A.; Okada, H.; Okada, K.; Oka, M.; Onuki, Y.; Oskarsson, A.; Ouchida, M.; Ozawa, K.; Pak, R.; Palounek, A. P. T.; Pantuev, V.; Papavassiliou, V.; Park, J.; Park, W. J.; Pate, S. F.; Pei, H.; Peng, J.-C.; Pereira, H.; Peresedov, V.; Peressounko, D. Yu.; Pinkenburg, C.; Purschke, M. L.; Purwar, A. K.; Qu, H.; Rak, J.; Rakotozafindrabe, A.; Ravinovich, I.; Read, K. F.; Rembeczki, S.; Reygers, K.; Riabov, V.; Riabov, Y.; Roach, D.; Roche, G.; Rolnick, S. D.; Rosati, M.; Rosendahl, S. S. E.; Rosnet, P.; Rukoyatkin, P.; Ružička, P.; Rykov, V. L.; Sahlmueller, B.; Saito, N.; Sakaguchi, T.; Sakai, S.; Sakashita, K.; Samsonov, V.; Sato, T.; Sawada, S.; Sedgwick, K.; Seele, J.; Seidl, R.; Semenov, A. Yu.; Semenov, V.; Seto, R.; Sharma, D.; Shein, I.; Shibata, T.-A.; Shigaki, K.; Shimomura, M.; Shoji, K.; Shukla, P.; Sickles, A.; Silva, C. L.; Silvermyr, D.; Silvestre, C.; Sim, K. S.; Singh, B. K.; Singh, C. P.; Singh, V.; Slunečka, M.; Soldatov, A.; Soltz, R. A.; Sondheim, W. E.; Sorensen, S. P.; Sourikova, I. V.; Staley, F.; Stankus, P. W.; Stenlund, E.; Stepanov, M.; Ster, A.; Stoll, S. P.; Sugitate, T.; Suire, C.; Sukhanov, A.; Sziklai, J.; Takagui, E. M.; Taketani, A.; Tanabe, R.; Tanaka, Y.; Tanida, K.; Tannenbaum, M. J.; Taranenko, A.; Tarján, P.; Themann, H.; Thomas, T. L.; Togawa, M.; Toia, A.; Tomášek, L.; Tomita, Y.; Torii, H.; Towell, R. S.; Tram, V.-N.; Tserruya, I.; Tsuchimoto, Y.; Vale, C.; Valle, H.; van Hecke, H. W.; Veicht, A.; Velkovska, J.; Vertesi, R.; Vinogradov, A. A.; Virius, M.; Vrba, V.; Vznuzdaev, E.; Wang, X. R.; Watanabe, Y.; Wei, F.; Wessels, J.; White, S. N.; Winter, D.; Woody, C. L.; Wysocki, M.; Xie, W.; Yamaguchi, Y. L.; Yamaura, K.; Yang, R.; Yanovich, A.; Ying, J.; Yokkaichi, S.; Young, G. R.; Younus, I.; Yushmanov, I. E.; Zajc, W. A.; Zaudtke, O.; Zhang, C.; Zhou, S.; Zolin, L.; PHENIX Collaboration
2010-07-01
We report the measurement of the transverse momentum dependence of inclusive J/ψ polarization in p+p collisions at s=200GeV performed by the PHENIX Experiment at the Relativistic Heavy Ion Collider. The J/ψ polarization is studied in the helicity, Gottfried-Jackson, and Collins-Soper frames for pT<5GeV/c and |y|<0.35. The polarization in the helicity and Gottfried-Jackson frames is consistent with zero for all transverse momenta, with a slight (1.8 sigma) trend towards longitudinal polarization for transverse momenta above 2GeV/c. No conclusion is allowed due to the limited acceptance in the Collins-Soper frame and the uncertainties of the current data. The results are compared to observations for other collision systems and center of mass energies and to different quarkonia production models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adare, A.; Bickley, A. A.; Ellinghaus, F.
We report the measurement of the transverse momentum dependence of inclusive J/{psi} polarization in p+p collisions at {radical}(s)=200 GeV performed by the PHENIX Experiment at the Relativistic Heavy Ion Collider. The J/{psi} polarization is studied in the helicity, Gottfried-Jackson, and Collins-Soper frames for p{sub T}<5 GeV/c and |y|<0.35. The polarization in the helicity and Gottfried-Jackson frames is consistent with zero for all transverse momenta, with a slight (1.8 sigma) trend towards longitudinal polarization for transverse momenta above 2 GeV/c. No conclusion is allowed due to the limited acceptance in the Collins-Soper frame and the uncertainties of the current data. Themore » results are compared to observations for other collision systems and center of mass energies and to different quarkonia production models.« less
Laparoscopic training model using fresh human cadavers without the establishment of penumoperitoneum
Imakuma, Ernesto Sasaki; Ussami, Edson Yassushi; Meyer, Alberto
2016-01-01
BACKGROUND: Laparoscopy is a well-established alternative to open surgery for treating many diseases. Although laparoscopy has many advantages, it is also associated with disadvantages, such as slow learning curves and prolonged operation time. Fresh frozen cadavers may be an interesting resource for laparoscopic training, and many institutions have access to cadavers. One of the main obstacles for the use of cadavers as a training model is the difficulty in introducing a sufficient pneumoperitoneum to distend the abdominal wall and provide a proper working space. The purpose of this study was to describe a fresh human cadaver model for laparoscopic training without requiring a pneumoperitoneum. MATERIALS AND METHODS AND RESULTS: A fake abdominal wall device was developed to allow for laparoscopic training without requiring a pneumoperitoneum in cadavers. The device consists of a table-mounted retractor, two rail clamps, two independent frame arms, two adjustable handle and rotating features, and two frames of the abdominal wall. A handycam is fixed over a frame arm, positioned and connected through a USB connection to a television and dissector; scissors and other laparoscopic materials are positioned inside trocars. The laparoscopic procedure is thus simulated. CONCLUSION: Cadavers offer a very promising and useful model for laparoscopic training. We developed a fake abdominal wall device that solves the limitation of space when performing surgery on cadavers and removes the need to acquire more costly laparoscopic equipment. This model is easily accessible at institutions in developing countries, making it one of the most promising tools for teaching laparoscopy. PMID:27073318
Potential capabilities for compression of information of certain data processing systems
NASA Technical Reports Server (NTRS)
Khodarev, Y. K.; Yevdokimov, V. P.; Pokras, V. M.
1974-01-01
This article undertakes to study a generalized block diagram of a data collection and processing system of a spacecraft in which a number of sensors or outputs of scientific instruments are cyclically interrogated by a commutator, methods of writing the supplementary information in a frame on the example of a certain hypothetical telemetry system, and the influence of statistics of number of active channels in a frame on frame compression factor. The separation of the data compression factor of the collection and processing system of spacecraft into two parts used in this work allows determination of the compression factor of an active frame depending not only on the statistics of activity of channels in the telemetry frame, but also on the method of introduction of the additional address and time information to each frame.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, Aaron P.; Carlson, Charles T.
A multi-part mask has a pattern plate, which includes a planar portion that has the desired aperture pattern to be used during workpiece processing. The multi-part mask also has a mounting frame, which is used to hold the pattern plate. Prior to assembly, the pattern plate has an aligning portion, which has one or more holes through which reusable alignment pins are inserted. These alignment pins enter kinematic joints disposed on the mounting frame, which serve to precisely align the pattern plate to the mounting frame. After the pattern plate has been secured to the mounting frame, the aligning portionmore » can be detached from the pattern plate. The alignment pins can be reused at a later time. In some embodiments, the pattern plate can later be removed from the mounting frame, so that the mounting frame may be reused.« less
What to do? The effects of discrepancies, incentives, and time on dynamic goal prioritization.
Schmidt, Aaron M; DeShon, Richard P
2007-07-01
This study examined factors that influence the dynamic pursuit of multiple goals over time. As hypothesized, goal-performance discrepancies were significantly related to subsequent time allocation. Greater distance from a given goal resulted in greater time subsequently allocated to that goal. In addition, the incentives offered for goal attainment determined the relative influence of discrepancies for each goal. When the incentives for each goal were equivalent, progress toward each goal exhibited equal influence, with greater time allocated to whichever goal was furthest from completion at the time. However, with an incentive available for only 1 of the 2 goals, time allocation was largely determined by progress toward the rewarded goal. Likewise, when incentives for each task differed in their approach-avoidance framing, progress toward the avoidance-framed goal was a stronger predictor of subsequent allocation than was progress toward the approach-framed goal. Finally, the influence of goal-performance discrepancies differed as a function of the time remaining for goal pursuit. The implications for future work on dynamic goal prioritization and the provision of performance incentives are discussed.
Rise time and response measurements on a LiSOCl2 cell
NASA Technical Reports Server (NTRS)
Bastien, Caroline; Lecomte, Eric J.
1992-01-01
Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.
Characterization, adaptive traffic shaping, and multiplexing of real-time MPEG II video
NASA Astrophysics Data System (ADS)
Agrawal, Sanjay; Barry, Charles F.; Binnai, Vinay; Kazovsky, Leonid G.
1997-01-01
We obtain network traffic model for real-time MPEG-II encoded digital video by analyzing video stream samples from real-time encoders from NUKO Information Systems. MPEG-II sample streams include a resolution intensive movie, City of Joy, an action intensive movie, Aliens, a luminance intensive (black and white) movie, Road To Utopia, and a chrominance intensive (color) movie, Dick Tracy. From our analysis we obtain a heuristic model for the encoded video traffic which uses a 15-stage Markov process to model the I,B,P frame sequences within a group of pictures (GOP). A jointly-correlated Gaussian process is used to model the individual frame sizes. Scene change arrivals are modeled according to a gamma process. Simulations show that our MPEG-II traffic model generates, I,B,P frame sequences and frame sizes that closely match the sample MPEG-II stream traffic characteristics as they relate to latency and buffer occupancy in network queues. To achieve high multiplexing efficiency we propose a traffic shaping scheme which sets preferred 1-frame generation times among a group of encoders so as to minimize the overall variation in total offered traffic while still allowing the individual encoders to react to scene changes. Simulations show that our scheme results in multiplexing gains of up to 10% enabling us to multiplex twenty 6 Mbps MPEG-II video streams instead of 18 streams over an ATM/SONET OC3 link without latency or cell loss penalty. This scheme is due for a patent.
Testing safety eyewear: how frame and lens design affect lens retention.
McMahon, Janice M; Beckerman, Stephen
2007-02-01
The aim of this study was to determine the role that frame and lens design play in lens retention during high-impact testing of safety eyewear that advertises conformance to the performance-based ANSI Z87.1-2003 standard. A total of 75 Z87 safety eyeglass frames (3 each of 25 frame models) were used in this study, procured from 5 of the leading U.S. safety frame manufacturers. Frames were fitted by an independent laboratory with 2.0-mm plano polycarbonate lenses in compliance with ANSI Z87.1-2003. Finished spectacles were sent to a subsequent laboratory testing facility where each frame was subjected to both high-mass and oblique-incidence high-velocity impacts to determine frame characteristics that were most highly associated with testing failure. Among the frame and lens parameters that were considered in this analysis were the A and B dimensions, effective diameter, distance between lenses, bridge type, frame material, bevel type, and frame cost. Certain variables were controlled for by maintaining consistency among all spectacle pairs, e.g., lens prescription, center thickness, and edge thickness. Multiple logistic regression was used to control potential confounding variables and to develop the best combination of them for predictive value. Of 25 separate frame models assessed, 10 passed both high-mass and high-velocity impact testing, i.e., none of the 3 frame/lens samples failed. Of the models that failed, 13 failures were caused by high-velocity testing, 1 by high-mass testing, and 1 failed both high-mass and high-velocity testing. None of the 15 spectacles with the SprinGuardtrade mark (Hilco, Plainville, Massachusetts) bevel design failed, although these were proprietary to 1 manufacturer and included only 5 frame models. Two spectacle designs (6 individual frames) incorporated an inverted bevel design of which 3 of the frames failed impact testing. Controlling for drop ball velocity among the 54 remaining standard "V" bevel spectacle pairs, the odds of failure were about 8 to 9 times higher for metal frames than Zylonite frames (odds ratio [OR], 8.5; 95% confidence interval [CI], 1.4 to 52.3; P = 0.02), and the odds of failure were about 4 times higher for lens effective diameters of less than 50 mm than for lens effective diameters more than 50 mm (OR, 4.1; 95% CI, 1.2 to 14.8; P = 0.03). Among our sample of safety spectacles, failure from high-mass impact resistance testing rarely occurred. No spectacles with the SprinGuard bevel design failed in our analysis, but this was limited to a small sample size from a single manufacturer. Among our sample of 54 spectacle pairs with a v-bevel design, metal frame material and an effective diameter of less than 50 mm were the strongest predictors of failure relative to high-velocity impact testing with a 45 degrees temporal angle projectile.
Video segmentation using keywords
NASA Astrophysics Data System (ADS)
Ton-That, Vinh; Vong, Chi-Tai; Nguyen-Dao, Xuan-Truong; Tran, Minh-Triet
2018-04-01
At DAVIS-2016 Challenge, many state-of-art video segmentation methods achieve potential results, but they still much depend on annotated frames to distinguish between background and foreground. It takes a lot of time and efforts to create these frames exactly. In this paper, we introduce a method to segment objects from video based on keywords given by user. First, we use a real-time object detection system - YOLOv2 to identify regions containing objects that have labels match with the given keywords in the first frame. Then, for each region identified from the previous step, we use Pyramid Scene Parsing Network to assign each pixel as foreground or background. These frames can be used as input frames for Object Flow algorithm to perform segmentation on entire video. We conduct experiments on a subset of DAVIS-2016 dataset in half the size of its original size, which shows that our method can handle many popular classes in PASCAL VOC 2012 dataset with acceptable accuracy, about 75.03%. We suggest widely testing by combining other methods to improve this result in the future.
Speech coding, reconstruction and recognition using acoustics and electromagnetic waves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holzrichter, J.F.; Ng, L.C.
The use of EM radiation in conjunction with simultaneously recorded acoustic speech information enables a complete mathematical coding of acoustic speech. The methods include the forming of a feature vector for each pitch period of voiced speech and the forming of feature vectors for each time frame of unvoiced, as well as for combined voiced and unvoiced speech. The methods include how to deconvolve the speech excitation function from the acoustic speech output to describe the transfer function each time frame. The formation of feature vectors defining all acoustic speech units over well defined time frames can be used formore » purposes of speech coding, speech compression, speaker identification, language-of-speech identification, speech recognition, speech synthesis, speech translation, speech telephony, and speech teaching. 35 figs.« less
Estimating the time evolution of NMR systems via a quantum-speed-limit-like expression
NASA Astrophysics Data System (ADS)
Villamizar, D. V.; Duzzioni, E. I.; Leal, A. C. S.; Auccaise, R.
2018-05-01
Finding the solutions of the equations that describe the dynamics of a given physical system is crucial in order to obtain important information about its evolution. However, by using estimation theory, it is possible to obtain, under certain limitations, some information on its dynamics. The quantum-speed-limit (QSL) theory was originally used to estimate the shortest time in which a Hamiltonian drives an initial state to a final one for a given fidelity. Using the QSL theory in a slightly different way, we are able to estimate the running time of a given quantum process. For that purpose, we impose the saturation of the Anandan-Aharonov bound in a rotating frame of reference where the state of the system travels slower than in the original frame (laboratory frame). Through this procedure it is possible to estimate the actual evolution time in the laboratory frame of reference with good accuracy when compared to previous methods. Our method is tested successfully to predict the time spent in the evolution of nuclear spins 1/2 and 3/2 in NMR systems. We find that the estimated time according to our method is better than previous approaches by up to four orders of magnitude. One disadvantage of our method is that we need to solve a number of transcendental equations, which increases with the system dimension and parameter discretization used to solve such equations numerically.
NASA Astrophysics Data System (ADS)
Mucha, Waldemar; Kuś, Wacław
2018-01-01
The paper presents a practical implementation of hybrid simulation using Real Time Finite Element Method (RTFEM). Hybrid simulation is a technique for investigating dynamic material and structural properties of mechanical systems by performing numerical analysis and experiment at the same time. It applies to mechanical systems with elements too difficult or impossible to model numerically. These elements are tested experimentally, while the rest of the system is simulated numerically. Data between the experiment and numerical simulation are exchanged in real time. Authors use Finite Element Method to perform the numerical simulation. The following paper presents the general algorithm for hybrid simulation using RTFEM and possible improvements of the algorithm for computation time reduction developed by the authors. The paper focuses on practical implementation of presented methods, which involves testing of a mountain bicycle frame, where the shock absorber is tested experimentally while the rest of the frame is simulated numerically.
The time-dependence of exchange-induced relaxation during modulated radio frequency pulses.
Sorce, Dennis J; Michaeli, Shalom; Garwood, Michael
2006-03-01
The problem of the relaxation of identical spins 1/2 induced by chemical exchange between spins with different chemical shifts in the presence of time-dependent RF irradiation (in the first rotating frame) is considered for the fast exchange regime. The solution for the time evolution under the chemical exchange Hamiltonian in the tilted doubly rotating frame (TDRF) is presented. Detailed derivation is specified to the case of a two-site chemical exchange system with complete randomization between jumps of the exchanging spins. The derived theory can be applied to describe the modulation of the chemical exchange relaxation rate constants when using a train of adiabatic pulses, such as the hyperbolic secant pulse. Theory presented is valid for quantification of the exchange-induced time-dependent rotating frame longitudinal T1rho,ex and transverse T2rho,ex relaxations in the fast chemical exchange regime.
National estimates of Australian gambling prevalence: f indings from a dual‐frame omnibus survey
Youssef, G. J.; Jackson, A. C.; Pennay, D. W.; Francis, K. L.; Pennay, A.; Lubman, D. I.
2016-01-01
Abstract Background, aims and design The increase in mobile telephone‐only households may be a source of bias for traditional landline gambling prevalence surveys. Aims were to: (1) identify Australian gambling participation and problem gambling prevalence using a dual‐frame (50% landline and 50% mobile telephone) computer‐assisted telephone interviewing methodology; (2) explore the predictors of sample frame and telephone status; and (3) explore the degree to which sample frame and telephone status moderate the relationships between respondent characteristics and problem gambling. Setting and participants A total of 2000 adult respondents residing in Australia were interviewed from March to April 2013. Measurements Participation in multiple gambling activities and Problem Gambling Severity Index (PGSI). Findings Estimates were: gambling participation [63.9%, 95% confidence interval (CI) = 61.4–66.3], problem gambling (0.4%, 95% CI = 0.2–0.8), moderate‐risk gambling (1.9%, 95% CI = 1.3–2.6) and low‐risk gambling (3.0%, 95% CI = 2.2–4.0). Relative to the landline frame, the mobile frame was more likely to gamble on horse/greyhound races [odds ratio (OR) = 1.4], casino table games (OR = 5.0), sporting events (OR = 2.2), private games (OR = 1.9) and the internet (OR = 6.5); less likely to gamble on lotteries (OR = 0.6); and more likely to gamble on five or more activities (OR = 2.4), display problem gambling (OR = 6.4) and endorse PGSI items (OR = 2.4‐6.1). Only casino table gambling (OR = 2.9) and internet gambling (OR = 3.5) independently predicted mobile frame membership. Telephone status (landline frame versus mobile dual users and mobile‐only users) displayed similar findings. Finally, sample frame and/or telephone status moderated the relationship between gender, relationship status, health and problem gambling (OR = 2.9–7.6). Conclusion Given expected future increases in the mobile telephone‐only population, best practice in population gambling research should use dual frame sampling methodologies (at least 50% landline and 50% mobile telephone) for telephone interviewing. PMID:26381314
Long-Term Variations of the EOP and ICRF2
NASA Technical Reports Server (NTRS)
Zharov, Vladimir; Sazhin, Mikhail; Sementsov, Valerian; Sazhina, Olga
2010-01-01
We analyzed the time series of the coordinates of the ICRF radio sources. We show that part of the radio sources, including the defining sources, shows a significant apparent motion. The stability of the celestial reference frame is provided by a no-net-rotation condition applied to the defining sources. In our case this condition leads to a rotation of the frame axes with time. We calculated the effect of this rotation on the Earth orientation parameters (EOP). In order to improve the stability of the celestial reference frame we suggest a new method for the selection of the defining sources. The method consists of two criteria: the first one we call cosmological and the second one kinematical. It is shown that a subset of the ICRF sources selected according to cosmological criteria provides the most stable reference frame for the next decade.
Flexible nuclear medicine camera and method of using
Dilmanian, F. Avraham; Packer, Samuel; Slatkin, Daniel N.
1996-12-10
A nuclear medicine camera 10 and method of use photographically record radioactive decay particles emitted from a source, for example a small, previously undetectable breast cancer, inside a patient. The camera 10 includes a flexible frame 20 containing a window 22, a photographic film 24, and a scintillation screen 26, with or without a gamma-ray collimator 34. The frame 20 flexes for following the contour of the examination site on the patient, with the window 22 being disposed in substantially abutting contact with the skin of the patient for reducing the distance between the film 24 and the radiation source inside the patient. The frame 20 is removably affixed to the patient at the examination site for allowing the patient mobility to wear the frame 20 for a predetermined exposure time period. The exposure time may be several days for obtaining early qualitative detection of small malignant neoplasms.
Multithreaded hybrid feature tracking for markerless augmented reality.
Lee, Taehee; Höllerer, Tobias
2009-01-01
We describe a novel markerless camera tracking approach and user interaction methodology for augmented reality (AR) on unprepared tabletop environments. We propose a real-time system architecture that combines two types of feature tracking. Distinctive image features of the scene are detected and tracked frame-to-frame by computing optical flow. In order to achieve real-time performance, multiple operations are processed in a synchronized multi-threaded manner: capturing a video frame, tracking features using optical flow, detecting distinctive invariant features, and rendering an output frame. We also introduce user interaction methodology for establishing a global coordinate system and for placing virtual objects in the AR environment by tracking a user's outstretched hand and estimating a camera pose relative to it. We evaluate the speed and accuracy of our hybrid feature tracking approach, and demonstrate a proof-of-concept application for enabling AR in unprepared tabletop environments, using bare hands for interaction.
Stability of Predictors of Mortality after Spinal Cord Injury
Krause, James S.; Saunders, Lee L.; Zhai, Yusheng
2011-01-01
Objective To identify the stability of socio-environmental, behavioral, and health predictors of mortality over an eight year time frame. Study Design Cohort study. Setting Data were analyzed at a large medical university in the Southeast United States of America (USA). Methods Adults with residual impairment from a spinal cord injury (SCI) who were at least one year post-injury at assessment were recruited through a large specialty hospital in the Southeast USA. 1209 participants were included in the final analysis. A piecewise exponential model with 2 equal time intervals (eight years total) was used to assess the stability of the hazard and the predictors over time. Results The hazard did significantly change over time, where the hazard in the first time interval was significantly lower than the second. There were no interactions between the socio-environmental, behavior, or health factors and time, although there was a significant interaction between age at injury (a demographic variable) and time. Conclusion These results suggest there is stability in the association between the predictors and mortality, even over an eight year time period. Results reinforce the use of historic variables for prediction of mortality in persons with SCI. PMID:22231541
A Content Analysis of Electronic Cigarette Portrayal in Newspapers
Yates, Katherine; Friedman, Katherine; Slater, Michael D.; Berman, Micah; Paskett, Electra D.; Ferketich, Amy K.
2015-01-01
Objective To determine how electronic cigarettes (e-cigarettes) are portrayed in newspaper informative articles and opinion pieces. Methods A content analysis was conducted on 450 articles published in the United States from 1997 to mid-2014 and obtained by a Newsbank search. The articles were reliably coded for overall frame, type of article, first topic and main topics addressed. Results The article topics have changed over time and suggest significant differences between news articles and opinion pieces. Informative articles focused on e-cigarette regulation, while opinion pieces highlighted their increasing popularity and perceived health benefits. Conclusions This content analysis uncovered significant interest in e-cigarettes, particularly in their regulation. The FDA should consider public perceptions of e-cigarettes when developing regulations. PMID:26229974
Design of light-small high-speed image data processing system
NASA Astrophysics Data System (ADS)
Yang, Jinbao; Feng, Xue; Li, Fei
2015-10-01
A light-small high speed image data processing system was designed in order to meet the request of image data processing in aerospace. System was constructed of FPGA, DSP and MCU (Micro-controller), implementing a video compress of 3 million pixels@15frames and real-time return of compressed image to the upper system. Programmable characteristic of FPGA, high performance image compress IC and configurable MCU were made best use to improve integration. Besides, hard-soft board design was introduced and PCB layout was optimized. At last, system achieved miniaturization, light-weight and fast heat dispersion. Experiments show that, system's multifunction was designed correctly and worked stably. In conclusion, system can be widely used in the area of light-small imaging.
Implications of an Absolute Simultaneity Theory for Cosmology and Universe Acceleration
Kipreos, Edward T.
2014-01-01
An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift–distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe. PMID:25536116
Implications of an absolute simultaneity theory for cosmology and universe acceleration.
Kipreos, Edward T
2014-01-01
An alternate Lorentz transformation, Absolute Lorentz Transformation (ALT), has similar kinematics to special relativity yet maintains absolute simultaneity in the context of a preferred reference frame. In this study, it is shown that ALT is compatible with current experiments to test Lorentz invariance only if the proposed preferred reference frame is locally equivalent to the Earth-centered non-rotating inertial reference frame, with the inference that in an ALT framework, preferred reference frames are associated with centers of gravitational mass. Applying this theoretical framework to cosmological data produces a scenario of universal time contraction in the past. In this scenario, past time contraction would be associated with increased levels of blueshifted light emissions from cosmological objects when viewed from our current perspective. The observation that distant Type Ia supernovae are dimmer than predicted by linear Hubble expansion currently provides the most direct evidence for an accelerating universe. Adjusting for the effects of time contraction on a redshift-distance modulus diagram produces a linear distribution of supernovae over the full redshift spectrum that is consistent with a non-accelerating universe.
Zhao, Xiaoquan; Peterson, Emily
2017-01-01
This study tested the effect of temporal framing on young adult smokers' response to antismoking communication messages. In two studies using largely identical designs, young adult smokers recruited from a large university (n = 52) and Amazon Mechanical Turk (n = 210) were exposed to either no messages or messages featuring different temporal frames. Analysis of the combined data (N = 262) showed that framing the health consequences of smoking in a proximal (vs. distal) time frame led to greater perceived message relevance, less use of heuristic processing, greater use of systematic processing, greater positive affect, and more intense fear. Mediation analysis showed that perceived relevance was a significant mediator of the effect of temporal framing on message processing and emotional responses. In separate analysis of the Amazon Mechanical Turk data, the proximal frame also showed a consistent pattern of stronger impact on behavioral intentions compared to the distal frame, but the difference was only significant on the measure of intending to try to quit. Overall, findings of this study suggest that using proximal (vs. distal) frames may enhance receptivity to antismoking messages among young adult smokers, although the behavioral impact of this framing strategy still awaits further research.
Dvorak, Robert D.; Pearson, Matthew R.; Neighbors, Clayton; Martens, Matthew P.
2015-01-01
OBJECTIVE Heavy alcohol use remains a consistent public health concern on college campuses. The current pilot study used Deviance Regulation Theory (DRT) to modify Protective Behavioral Strategies (PBS) among college student drinkers to reduce alcohol use and alcohol-related consequences. METHODS The sample was comprised of current college student drinkers (n = 76; 53.95% female) ranging in age from 18-24 (M = 19.29, SD = 1.42). Participants were randomly assigned to receive a positive or negative framed message. They then reported on use of alcohol protective behavioral strategies (via the Protective Behavioral Strategies Scale), alcohol consumption (via the Modified Daily Drinking Questionnaire), and alcohol-related consequences (via the Young Adults Alcohol Consequences Questionnaire) each week for six weeks. RESULTS AND CONCLUSIONS Among drinkers with low PBS use norms, a positively, versus a negatively, framed message resulted in increased PBS use and consequently less alcohol consumption and fewer alcohol-related consequences. Among drinkers with high PBS use norms, a negatively, versus positively, framed message resulted in increased PBS use and consequently lower alcohol consumption and fewer alcohol-related consequences. However, these effects were only relevant among those who strongly believed the DRT frame. Findings suggest assigning drinkers to frames based on perceived PBS use norms and increasing belief in the frame may be one approach to increasing responsible drinking patterns among college students. Furthermore, the current data suggests important boundary conditions for norm-based interventions. PUBLIC HEALTH RELEVANCE This study of college student drinkers who received either a positive or negative framed message about reducing their drinking found that a Deviance Regulation intervention might be effective at increasing responsible alcohol use, but only among students with a high acceptance of the intervention materials. PMID:25798727
Serial changes of humor comprehension for four-frame comic Manga: an fMRI study
Osaka, Mariko; Yaoi, Ken; Minamoto, Takehiro; Osaka, Naoyuki
2014-01-01
Serial changes of humor comprehension evoked by a well organized four-frame comic Manga were investigated by fMRI in each step of humor comprehension. The neural substrates underlying the amusing effects in response to funny and mixed order manga were compared. In accordance with the time course of the four frames, fMRI activations changed serially. Beginning with the second frame (development scene), activation of the temporo-parietal junction (TPJ) was observed, followed by activations in the temporal and frontal areas during viewing of the third frame (turn scene). For the fourth frame (punch line), strong increased activations were confirmed in the medial prefrontal cortex (MPFC) and cerebellum. Interestingly, distinguishable activation differences in the cerebellum between funny and non-funny conditions were also found for the fourth frame. These findings suggest that humor comprehension evokes activation that initiates in the TPJ and expands to the MPFC and cerebellum at the convergence level. PMID:25059843
NASA Astrophysics Data System (ADS)
Lazarev, Grigory; Bonifer, Stefanie; Engel, Philip; Höhne, Daniel; Notni, Gunther
2017-06-01
We report about the implementation of the liquid crystal on silicon (LCOS) microdisplay with 1920 by 1080 resolution and 720 Hz frame rate. The driving solution is FPGA-based. The input signal is converted from the ultrahigh-resolution HDMI 2.0 signal into HD frames, which follow with the specified 720 Hz frame rate. Alternatively the signal is generated directly on the FPGA with built-in pattern generator. The display is showing switching times below 1.5 ms for the selected working temperature. The bit depth of the addressed image achieves 8 bit within each frame. The microdisplay is used in the fringe projection-based 3D sensing system, implemented by Fraunhofer IOF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
J Zwan, B; Central Coast Cancer Centre, Gosford, NSW; Colvill, E
2016-06-15
Purpose: The added complexity of the real-time adaptive multi-leaf collimator (MLC) tracking increases the likelihood of undetected MLC delivery errors. In this work we develop and test a system for real-time delivery verification and error detection for MLC tracking radiotherapy using an electronic portal imaging device (EPID). Methods: The delivery verification system relies on acquisition and real-time analysis of transit EPID image frames acquired at 8.41 fps. In-house software was developed to extract the MLC positions from each image frame. Three comparison metrics were used to verify the MLC positions in real-time: (1) field size, (2) field location and, (3)more » field shape. The delivery verification system was tested for 8 VMAT MLC tracking deliveries (4 prostate and 4 lung) where real patient target motion was reproduced using a Hexamotion motion stage and a Calypso system. Sensitivity and detection delay was quantified for various types of MLC and system errors. Results: For both the prostate and lung test deliveries the MLC-defined field size was measured with an accuracy of 1.25 cm{sup 2} (1 SD). The field location was measured with an accuracy of 0.6 mm and 0.8 mm (1 SD) for lung and prostate respectively. Field location errors (i.e. tracking in wrong direction) with a magnitude of 3 mm were detected within 0.4 s of occurrence in the X direction and 0.8 s in the Y direction. Systematic MLC gap errors were detected as small as 3 mm. The method was not found to be sensitive to random MLC errors and individual MLC calibration errors up to 5 mm. Conclusion: EPID imaging may be used for independent real-time verification of MLC trajectories during MLC tracking deliveries. Thresholds have been determined for error detection and the system has been shown to be sensitive to a range of delivery errors.« less
Digital movie-based on automatic titrations.
Lima, Ricardo Alexandre C; Almeida, Luciano F; Lyra, Wellington S; Siqueira, Lucas A; Gaião, Edvaldo N; Paiva Junior, Sérgio S L; Lima, Rafaela L F C
2016-01-15
This study proposes the use of digital movies (DMs) in a flow-batch analyzer (FBA) to perform automatic, fast and accurate titrations. The term used for this process is "Digital movie-based on automatic titrations" (DMB-AT). A webcam records the DM during the addition of the titrant to the mixing chamber (MC). While the DM is recorded, it is decompiled into frames ordered sequentially at a constant rate of 26 frames per second (FPS). The first frame is used as a reference to define the region of interest (ROI) of 28×13pixels and the R, G and B values, which are used to calculate the Hue (H) values for each frame. The Pearson's correlation coefficient (r) is calculated between the H values of the initial frame and each subsequent frame. The titration curves are plotted in real time using the r values and the opening time of the titrant valve. The end point is estimated by the second derivative method. A software written in C language manages all analytical steps and data treatment in real time. The feasibility of the method was attested by application in acid/base test samples and edible oils. Results were compared with classical titration and did not present statistically significant differences when the paired t-test at the 95% confidence level was applied. The proposed method is able to process about 117-128 samples per hour for the test and edible oil samples, respectively, and its precision was confirmed by overall relative standard deviation (RSD) values, always less than 1.0%. Copyright © 2015 Elsevier B.V. All rights reserved.
Teachers' Practices of Inquiry When Teaching Investigations: A Case Study
ERIC Educational Resources Information Center
Dudu, Washington T.; Vhurumuku, Elaosi
2012-01-01
Teacher practices are essential for supporting learners in scientific inquiry practices of framing research questions, designing and conducting investigations, collecting data, and drawing conclusions. This study examines instructional practices of two Grade 11 Physical Science teachers engaged in teaching practical investigations. Data were…
Barr, Margo L; Ferguson, Raymond A; Hughes, Phil J; Steel, David G
2014-09-04
In 2012 mobile phone numbers were included into the ongoing New South Wales Population Health Survey (NSWPHS) using an overlapping dual-frame design. Previously in the NSWPHS the sample was selected using random digit dialing (RDD) of landline phone numbers. The survey was undertaken using computer assisted telephone interviewing (CATI). The weighting strategy needed to be significantly expanded to manage the differing probabilities of selection by frame, including that of children of mobile-only phone users, and to adjust for the increased chance of selection of dual-phone users. This paper describes the development of the final weighting strategy to properly combine the data from two overlapping sample frames accounting for the fact that population benchmarks for the different sampling frames were not available at the state or regional level. Estimates of the number of phone numbers for the landline and mobile phone frames used to calculate the differing probabilities of selection by frame, for New South Wales (NSW) and by stratum, were obtained by apportioning Australian estimates as none were available for NSW. The weighting strategy was then developed by calculating person selection probabilities, selection weights, applying a constant composite factor to the dual-phone users sample weights, and benchmarking to the latest NSW population by age group, sex and stratum. Data from the NSWPHS for the first quarter of 2012 was used to test the weighting strategy. This consisted of data on 3395 respondents with 2171 (64%) from the landline frame and 1224 (36%) from the mobile frame. However, in order to calculate the weights, data needed to be available for all core weighting variables and so 3378 respondents, 2933 adults and 445 children, had sufficient data to be included. Average person weights were 3.3 times higher for the mobile-only respondents, 1.3 times higher for the landline-only respondents and 1.7 times higher for dual-phone users in the mobile frame compared to the dual-phone users in the landline frame. The overall weight effect for the first quarter of 2012 was 1.93 and the coefficient of variation of the weights was 0.96. The weight effects for 2012 were similar to, and in many cases less than, the effects found in the corresponding quarter of the 2011 NSWPHS when only a landline based sample was used. The inclusion of mobile phone numbers, through an overlapping dual-frame design, improved the coverage of the survey and an appropriate weighing procedure is feasible, although it added substantially to the complexity of the weighting strategy. Access to accurate Australian, State and Territory estimates of the number of landline and mobile phone numbers and type of phone use by at least age group and sex would greatly assist in the weighting of dual-frame surveys in Australia.
Self-guide framing and persuasion: responsibly increasing message processing to ideal levels.
Evans, Lisa M; Petty, Richard E
2003-03-01
The current research examines the effect that framing persuasive messages in terms of self-guides (ideal vs. ought) has on the attitudes and cognitive responses of individuals with chronic ideal versus ought self-guides. The strength of participants' ideal and ought self-guides and the magnitude of participants' ideal and ought self-discrepancies were measured using a computerized reaction time program. One week later, participants read a persuasive message about a fictional breakfast product, framed in terms of either ideals or oughts. Matching framing to stronger self-guide led to enhanced message processing activity, especially among individuals who were low in need for cognition. Individuals who read messages framed to match their stronger self-guides paid more attention to argument quality, as reflected in their attitudes and cognitive responses. Messages with self-guide framing that matched individuals' stronger self-discrepancies did not have this effect on processing.
Real time magnetic resonance guided endomyocardial local delivery
Corti, R; Badimon, J; Mizsei, G; Macaluso, F; Lee, M; Licato, P; Viles-Gonzalez, J F; Fuster, V; Sherman, W
2005-01-01
Objective: To investigate the feasibility of targeting various areas of left ventricle myocardium under real time magnetic resonance (MR) imaging with a customised injection catheter equipped with a miniaturised coil. Design: A needle injection catheter with a mounted resonant solenoid circuit (coil) at its tip was designed and constructed. A 1.5 T MR scanner with customised real time sequence combined with in-room scan running capabilities was used. With this system, various myocardial areas within the left ventricle were targeted and injected with a gadolinium-diethylenetriaminepentaacetic acid (DTPA) and Indian ink mixture. Results: Real time sequencing at 10 frames/s allowed clear visualisation of the moving catheter and its transit through the aorta into the ventricle, as well as targeting of all ventricle wall segments without further image enhancement techniques. All injections were visualised by real time MR imaging and verified by gross pathology. Conclusion: The tracking device allowed real time in vivo visualisation of catheters in the aorta and left ventricle as well as precise targeting of myocardial areas. The use of this real time catheter tracking may enable precise and adequate delivery of agents for tissue regeneration. PMID:15710717
High-frame rate multiport CCD imager and camera
NASA Astrophysics Data System (ADS)
Levine, Peter A.; Patterson, David R.; Esposito, Benjamin J.; Tower, John R.; Lawler, William B.
1993-01-01
A high frame rate visible CCD camera capable of operation up to 200 frames per second is described. The camera produces a 256 X 256 pixel image by using one quadrant of a 512 X 512 16-port, back illuminated CCD imager. Four contiguous outputs are digitally reformatted into a correct, 256 X 256 image. This paper details the architecture and timing used for the CCD drive circuits, analog processing, and the digital reformatter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miranda, D.; Instituto Politécnico de Viana do Castelo, Viana do Castelo; Miranda, F.
2016-06-08
Tailoring battery geometries is essential for many applications, as geometry influences the delivered capacity value. Two geometries, frame and conventional, have been studied and, for a given scan rate of 330C, the square frame shows a capacity value of 305,52 Ahm{sup −2}, which is 527 times higher than the one for the conventional geometry for a constant the area of all components.
Recall and Effectiveness of Messages Promoting Smoke-Free Policies in Rural Communities
Butler, Karen M.; Wiggins, Amanda T.; Kostygina, Ganna; Langley, Ronald E.; Hahn, Ellen J.
2016-01-01
Abstract Introduction: Low-cost media campaigns increase demand for smoke-free policies in underserved rural areas. The study examined the impact of loss- and gain-framed smoke-free print ads on recall and perceived effectiveness in rural communities, controlling for personal characteristics. Methods: Following 6- to 9-month print media campaigns in three rural counties, recall and perceived effectiveness of loss-framed (ie, targeting dangers of secondhand smoke [SHS]) and gain-framed (ie, highlighting positive aspects of smoke-free air) ads were assessed using random-digit-dial phone surveys. Respondents were asked if they remembered each ad, whether they liked it, whether they were prompted to contact a smoke-free coalition, whether the ad made them think, and whether it prompted emotion. Mixed modeling assessed whether personal factors predicted ad recall or perceived effectiveness. Results: Loss-framed ads were less likely to be recalled but more likely to prompt emotion. For ads of both frame types, females reported greater recall and perceived effectiveness than males. Those with less education reported higher perceived effectiveness of the ads but lower recall. Nonsmokers were more likely than smokers to perceive the ads as effective. Knowledge of SHS risk and support for smoke-free workplaces were positively associated with recall and effectiveness. Conclusions: Ad recall and perceived effectiveness were associated with framing and demographic and personal characteristics. Smoke-free efforts in rural areas may be bolstered by continuing to promote benefits of smoke-free workplace policies and educate on SHS risks. Rural areas may need to provide a combination of ad types and framing strategies to appeal to a wide audience. Implications: Rural communities are disproportionately affected by SHS and less likely to be protected by smoke-free policies. This study adds evidence-based guidance for tailoring rural smoke-free media campaigns using different framing: gain-framed messages (ie, benefits of smoke-free environments) to promote recall and loss-framed content (ie, dangers of SHS) to prompt emotion. Further, gain-framed messages that are localized to the rural community may be especially effective. Findings support designing smoke-free campaigns in rural communities with the audience in mind by tailoring messages to age, sex, and education level. PMID:26385925
Framing of feedback impacts student's satisfaction, self-efficacy and performance.
van de Ridder, J M Monica; Peters, Claudia M M; Stokking, Karel M; de Ru, J Alexander; Ten Cate, Olle Th J
2015-08-01
Feedback is considered important to acquire clinical skills. Research evidence shows that feedback does not always improve learning and its effects may be small. In many studies, a variety of variables involved in feedback provision may mask either one of their effects. E.g., there is reason to believe that the way oral feedback is framed may affect its effect if other variables are held constant. In a randomised controlled trial we investigated the effect of positively and negatively framed feedback messages on satisfaction, self-efficacy, and performance. A single blind randomised controlled between-subject design was used, with framing of the feedback message (positively-negatively) as independent variable and examination of hearing abilities as the task. First year medical students' (n = 59) satisfaction, self-efficacy, and performance were the dependent variables and were measured both directly after the intervention and after a 2 weeks delay. Students in the positively framed feedback condition were significantly more satisfied and showed significantly higher self-efficacy measured directly after the performance. Effect sizes found were large, i.e., partial η (2) = 0.43 and η (2) = 0.32 respectively. They showed a better performance throughout the whole study. Significant performance differences were found both at the initial performance and when measured 2 weeks after the intervention: effects were of medium size, respectively r = -.31 and r = -.32. Over time in both conditions performance and self-efficacy decreased. Framing the feedback message in either a positive or negative manner affects students' satisfaction and self-efficacy directly after the intervention be it that these effects seem to fade out over time. Performance may be enhanced by positive framing, but additional studies need to confirm this. We recommend using a positive frame when giving feedback on clinical skills.
Real-time image sequence segmentation using curve evolution
NASA Astrophysics Data System (ADS)
Zhang, Jun; Liu, Weisong
2001-04-01
In this paper, we describe a novel approach to image sequence segmentation and its real-time implementation. This approach uses the 3D structure tensor to produce a more robust frame difference signal and uses curve evolution to extract whole objects. Our algorithm is implemented on a standard PC running the Windows operating system with video capture from a USB camera that is a standard Windows video capture device. Using the Windows standard video I/O functionalities, our segmentation software is highly portable and easy to maintain and upgrade. In its current implementation on a Pentium 400, the system can perform segmentation at 5 frames/sec with a frame resolution of 160 by 120.
Earth - South America (first frame of Earth Spin Movie)
NASA Technical Reports Server (NTRS)
1990-01-01
This color image of the Earth was obtained by Galileo at about 6:10 a.m. Pacific Standard Time on Dec. 11, 1990, when the spacecraft was about 1.3 million miles from the planet during the first of two Earth flybys on its way to Jupiter. The color composite used images taken through the red, green and violet filters. South America is near the center of the picture, and the white, sunlit continent of Antarctica is below. Picturesque weather fronts are visible in the South Atlantic, lower right. This is the first frame of the Galileo Earth spin movie, a 500- frame time-lapse motion picture showing a 25-hour period of Earth's rotation and atmospheric dynamics.
Liu, Jenny J. W.
2017-01-01
Background The consequences of stress are typically regarded from a deficit-oriented approach, conceptualizing stress to be entirely negative in its outcomes. This approach is unbalanced, and may further hinder individuals from engaging in adaptive coping. In the current study, we explored whether negative views and beliefs regarding stress interacted with a stress framing manipulation (positive, neutral and negative) on measures of stress reactivity for both psychosocial and physiological stressors. Method Ninety participants were randomized into one of three framing conditions that conceptualized the experience of stress in balanced, unbalanced-negative or unbalanced-positive ways. After watching a video on stress, participants underwent a psychosocial (Trier Social Stress Test), or a physiological (CO2 challenge) method of stress-induction. Subjective and objective markers of stress were assessed. Results Most of the sampled population regarded stress as negative prior to framing. Further, subjective and objective reactivity were greater to the TSST compared to the CO2 challenge. Additionally, significant cubic trends were observed in the interactions of stress framing and stress-induction methodologies on heart rate and blood pressure. Balanced framing conditions in the TSST group had a significantly larger decrease in heart rate and diastolic blood pressure following stress compared to the positive and negative framing conditions. Conclusion Findings confirmed a deficit-orientation of stress within the sampled population. In addition, results highlighted the relative efficacy of the TSST compared to CO2 as a method of stress provocation. Finally, individuals in framing conditions that posited stress outcomes in unbalanced manners responded to stressors less efficiently. This suggests that unbalanced framing of stress may have set forth unrealistic expectations regarding stress that later hindered individuals from adaptive responses to stress. Potential benefits of alternative conceptualizations of stress on stress reactivity are discussed, and suggestions for future research are made. PMID:28273132
High-speed adaptive optics line scan confocal retinal imaging for human eye
Wang, Xiaolin; Zhang, Yuhua
2017-01-01
Purpose Continuous and rapid eye movement causes significant intraframe distortion in adaptive optics high resolution retinal imaging. To minimize this artifact, we developed a high speed adaptive optics line scan confocal retinal imaging system. Methods A high speed line camera was employed to acquire retinal image and custom adaptive optics was developed to compensate the wave aberration of the human eye’s optics. The spatial resolution and signal to noise ratio were assessed in model eye and in living human eye. The improvement of imaging fidelity was estimated by reduction of intra-frame distortion of retinal images acquired in the living human eyes with frame rates at 30 frames/second (FPS), 100 FPS, and 200 FPS. Results The device produced retinal image with cellular level resolution at 200 FPS with a digitization of 512×512 pixels/frame in the living human eye. Cone photoreceptors in the central fovea and rod photoreceptors near the fovea were resolved in three human subjects in normal chorioretinal health. Compared with retinal images acquired at 30 FPS, the intra-frame distortion in images taken at 200 FPS was reduced by 50.9% to 79.7%. Conclusions We demonstrated the feasibility of acquiring high resolution retinal images in the living human eye at a speed that minimizes retinal motion artifact. This device may facilitate research involving subjects with nystagmus or unsteady fixation due to central vision loss. PMID:28257458
Positioning women's and children's health in African union policy-making: a policy analysis
2012-01-01
Background With limited time to achieve the Millennium Development Goals, progress towards improving women's and children's health needs to be accelerated. With Africa accounting for over half of the world's maternal and child deaths, the African Union (AU) has a critical role in prioritizing related policies and catalysing required investments and action. In this paper, the authors assess the evolution of African Union policies related to women's and children's health, and analyze how these policies are prioritized and framed. Methods The main method used in this policy analysis was a document review of all African Union policies developed from 1963 to 2010, focusing specifically on policies that explicitly mention health. The findings from this document review were discussed with key actors to identify policy implications. Results With over 220 policies in total, peace and security is the most common AU policy topic. Social affairs and other development issues became more prominent in the 1990s. The number of policies that mentioned health rose steadily over the years (with 1 policy mentioning health in 1963 to 7 in 2010). This change was catalysed by factors such as: a favourable shift in AU priorities and systems towards development issues, spurred by the transition from the Organization of African Unity to the African Union; the mandate of the African Commission on Human and People's Rights; health-related advocacy initiatives, such as the Campaign for the Accelerated Reduction of Maternal Mortality in Africa (CARMMA); action and accountability requirements arising from international human rights treaties, the Millennium Development Goals (MDGs), and new health-funding mechanisms, such as the Global Fund to Fight AIDS, Tuberculosis and Malaria. Prioritization of women's and children's health issues in AU policies has been framed primarily by human rights, advocacy and accountability considerations, more by economic and health frames looking at investments and impact. AU policies related to reproductive, maternal, newborn and child health also use fewer policy frames than do AU policies related to HIV/AIDS, tuberculosis and malaria. Conclusion We suggest that more effective prioritization of women's and children's health in African Union policies would be supported by widening the range of policy frames used (notably health and economic) and strengthening the evidence base of all policy frames used. In addition, we suggest it would be beneficial if the partner groups advocating for women's and children's health were multi-stakeholder, and included, for instance, health care professionals, regional institutions, parliamentarians, the media, academia, NGOs, development partners and the public and private sectors. PMID:22340362
Code of Federal Regulations, 2011 CFR
2011-01-01
... Overseas Private Investment Corporation may accompany the visiting vice president of the U.S. company to a... Administrative Personnel OFFICE OF GOVERNMENT ETHICS GOVERNMENT ETHICS STANDARDS OF ETHICAL CONDUCT FOR EMPLOYEES... technology. At the conclusion of his speech, the association presents the employee a framed map with a market...
ERIC Educational Resources Information Center
Kanter, Elliot
1977-01-01
The events and revelations before and since the arrest of Paul Skyhorse and Richard Mohawk (two American Indian Movement organizers charged with the 1974 murder of a taxi driver at AIM Camp 13) lead to the inevitable conclusion that these men are victims of a frame-up. (Author/JC)
Evaluation of Eye Metrics as a Detector of Fatigue
2010-03-01
eyeglass frames . The cameras are angled upward toward the eyes and extract real-time pupil diameter, eye-lid movement, and eye-ball movement. The...because the cameras were mounted on eyeglass -like frames , the system was able to continuously monitor the eye throughout all sessions. Overall, the...of “ fitness for duty” testing and “real-time monitoring” of operator performance has been slow (Institute of Medicine, 2004). Oculometric-based
Sporadic frame dropping impact on quality perception
NASA Astrophysics Data System (ADS)
Pastrana-Vidal, Ricardo R.; Gicquel, Jean Charles; Colomes, Catherine; Cherifi, Hocine
2004-06-01
Over the past few years there has been an increasing interest in real time video services over packet networks. When considering quality, it is essential to quantify user perception of the received sequence. Severe motion discontinuities are one of the most common degradations in video streaming. The end-user perceives a jerky motion when the discontinuities are uniformly distributed over time and an instantaneous fluidity break is perceived when the motion loss is isolated or irregularly distributed. Bit rate adaptation techniques, transmission errors in the packet networks or restitution strategy could be the origin of this perceived jerkiness. In this paper we present a psychovisual experiment performed to quantify the effect of sporadically dropped pictures on the overall perceived quality. First, the perceptual detection thresholds of generated temporal discontinuities were measured. Then, the quality function was estimated in relation to a single frame dropping for different durations. Finally, a set of tests was performed to quantify the effect of several impairments distributed over time. We have found that the detection thresholds are content, duration and motion dependent. The assessment results show how quality is impaired by a single burst of dropped frames in a 10 sec sequence. The effect of several bursts of discarded frames, irregularly distributed over the time is also discussed.
Watanabe, Yuuki; Maeno, Seiya; Aoshima, Kenji; Hasegawa, Haruyuki; Koseki, Hitoshi
2010-09-01
The real-time display of full-range, 2048?axial pixelx1024?lateral pixel, Fourier-domain optical-coherence tomography (FD-OCT) images is demonstrated. The required speed was achieved by using dual graphic processing units (GPUs) with many stream processors to realize highly parallel processing. We used a zero-filling technique, including a forward Fourier transform, a zero padding to increase the axial data-array size to 8192, an inverse-Fourier transform back to the spectral domain, a linear interpolation from wavelength to wavenumber, a lateral Hilbert transform to obtain the complex spectrum, a Fourier transform to obtain the axial profiles, and a log scaling. The data-transfer time of the frame grabber was 15.73?ms, and the processing time, which includes the data transfer between the GPU memory and the host computer, was 14.75?ms, for a total time shorter than the 36.70?ms frame-interval time using a line-scan CCD camera operated at 27.9?kHz. That is, our OCT system achieved a processed-image display rate of 27.23 frames/s.
Visual tracking using neuromorphic asynchronous event-based cameras.
Ni, Zhenjiang; Ieng, Sio-Hoi; Posch, Christoph; Régnier, Stéphane; Benosman, Ryad
2015-04-01
This letter presents a novel computationally efficient and robust pattern tracking method based on a time-encoded, frame-free visual data. Recent interdisciplinary developments, combining inputs from engineering and biology, have yielded a novel type of camera that encodes visual information into a continuous stream of asynchronous, temporal events. These events encode temporal contrast and intensity locally in space and time. We show that the sparse yet accurately timed information is well suited as a computational input for object tracking. In this letter, visual data processing is performed for each incoming event at the time it arrives. The method provides a continuous and iterative estimation of the geometric transformation between the model and the events representing the tracked object. It can handle isometry, similarities, and affine distortions and allows for unprecedented real-time performance at equivalent frame rates in the kilohertz range on a standard PC. Furthermore, by using the dimension of time that is currently underexploited by most artificial vision systems, the method we present is able to solve ambiguous cases of object occlusions that classical frame-based techniques handle poorly.
MacKenzie, Ross; Chapman, Simon; Holding, Simon; McGeechan, Kevin
2007-01-01
Objective Despite a near universal absence of evidence-based policies supporting population screening for prostate cancer, the prostate-specific antigen (PSA) test is aggressively promoted in the media as a life-saving form of screening. The objective of this study was to examine media coverage of prostate-cancer screening in Australia. Design Frame analysis of all direct or attributed quotes about prostate cancer. Setting Australian capital city newspapers (February 2003-December 2006) and Sydney television news (January 2003-December 2006). Main outcome measures Quotes regarding prostate cancer screening: n=436 in newspapers and television news. Results Seven rhetorical frames were identified. 86% of all quotes framed prostate screening and its outcomes as desirable, associating PSA testing as being consonant with other early-detection cancer-control messages. Adverse surgical sequelae to screening were often minimized, scientific progress highlighted and gender equity appeals appropriated. Those questioning screening were vilified, with epidemiology being framed as an inferior form of knowledge than clinical experience. Conclusions Australian men are exposed to unbalanced and often non-evidence-based appeals to seek PSA testing. There is a disturbing lack of effort to redress this imbalance. PMID:18048709
Blows, S; Ivers, R; Chapman, S
2005-01-01
Objective: To catalogue arguments that can be anticipated in public debate when passenger and night driving restrictions are being advocated. Design and setting: Frame analysis of all relevant coverage of these topics in Australian print media during the three month period between June and September 2004 when intensive debate on the topic occurred. Main outcome measures: Debating frames used in reports and commentary on passenger and night driving restrictions. Results: There were 52 relevant articles published containing seven distinct frames supporting the restrictions and six opposing them. Overall, more instances of frames supporting the restrictions were published; these mostly focused on the potential for saving lives. Opposition to the restrictions focused largely on their inappropriateness as a road safety measure as well as on the importance of young people's autonomy and freedom. Conclusions: Advocates of passenger and night driving restrictions have a number of arguments available to advance their case; however, it is important to anticipate and address possible counter arguments. Future research should address the saliency of different arguments to the public and key decision makers in government. PMID:16203840
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, J
2016-06-15
Purpose: Develop a method to maximize the noncoplanar beam orientations and assure the beam delivery clearance for SBRT, therefore, optimize the dose conformality to the target, increase the dose sparing to the critical normal organs and reduce the hot spots in the body. Methods: A SBRT body frame (Elekta, Stockholm, Sweden) was used for patient immobilization and target localization. The SBRT body frame has CT fiducials on its side frames. After patient’s CT scan, the radiation treatment isocenter was defined and its coordinators referring to the body frame was calculated in the radiation treatment planning process. Meanwhile, initial beam orientationsmore » were designed based on the patient target and critical organ anatomy. The body frame was put on the linear accelerator couch and positioned to the calculated isocenter. Initially designed beam orientations were manually measured by tuning the body frame position on the couch, the gantry and couch angles. The finalized beam orientations were put into the treatment planning for dosimetric calculations. Results: Without patient presence, an optimal set of beam orientations were designed and validated. The radiation treatment plan was optimized and guaranteed for delivery clearance. Conclusion: The developed method is beneficial and effective in SBRT treatment planning for individual patient. It first allows maximizing the achievable noncoplanar beam orientation space, therefore, optimize the treatment plan for specific patient. It eliminates the risk that a plan needs to be modified due to the gantry and couch collision during patient setup.« less
Cerina, Luca; Iozzia, Luca; Mainardi, Luca
2017-11-14
In this paper, common time- and frequency-domain variability indexes obtained by pulse rate variability (PRV) series extracted from video-photoplethysmographic signal (vPPG) were compared with heart rate variability (HRV) parameters calculated from synchronized ECG signals. The dual focus of this study was to analyze the effect of different video acquisition frame-rates starting from 60 frames-per-second (fps) down to 7.5 fps and different video compression techniques using both lossless and lossy codecs on PRV parameters estimation. Video recordings were acquired through an off-the-shelf GigE Sony XCG-C30C camera on 60 young, healthy subjects (age 23±4 years) in the supine position. A fully automated, signal extraction method based on the Kanade-Lucas-Tomasi (KLT) algorithm for regions of interest (ROI) detection and tracking, in combination with a zero-phase principal component analysis (ZCA) signal separation technique was employed to convert the video frames sequence to a pulsatile signal. The frame-rate degradation was simulated on video recordings by directly sub-sampling the ROI tracking and signal extraction modules, to correctly mimic videos recorded at a lower speed. The compression of the videos was configured to avoid any frame rejection caused by codec quality leveling, FFV1 codec was used for lossless compression and H.264 with variable quality parameter as lossy codec. The results showed that a reduced frame-rate leads to inaccurate tracking of ROIs, increased time-jitter in the signals dynamics and local peak displacements, which degrades the performances in all the PRV parameters. The root mean square of successive differences (RMSSD) and the proportion of successive differences greater than 50 ms (PNN50) indexes in time-domain and the low frequency (LF) and high frequency (HF) power in frequency domain were the parameters which highly degraded with frame-rate reduction. Such a degradation can be partially mitigated by up-sampling the measured signal at a higher frequency (namely 60 Hz). Concerning the video compression, the results showed that compression techniques are suitable for the storage of vPPG recordings, although lossless or intra-frame compression are to be preferred over inter-frame compression methods. FFV1 performances are very close to the uncompressed (UNC) version with less than 45% disk size. H.264 showed a degradation of the PRV estimation directly correlated with the increase of the compression ratio.
SEO, MYEONG-GU; GOLDFARB, BRENT; BARRETT, LISA FELDMAN
2011-01-01
We examined the role of affect (pleasant or unpleasant feelings) and decision frames (gains or losses) in risk taking in a 20-day stock investment simulation in which 101 participants rated their current feelings while making investment decisions. As predicted, affect attenuated the relationships between decision frames and risk taking. After experiencing losses, individuals made more risky choices, in keeping with the framing effect. However, this tendency decreased and/or disappeared when loss was simultaneously experienced with either pleasant or unpleasant feelings. Similarly, individuals’ tendency to avoid risk after experiencing gains disappeared or even reversed when they simultaneously experienced pleasant feelings. PMID:26412860
Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera
NASA Technical Reports Server (NTRS)
Parker, Vance C.; Crews, Jeanne Lee
1988-01-01
The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.
Seo, Myeong-Gu; Goldfarb, Brent; Barrett, Lisa Feldman
2010-04-01
We examined the role of affect (pleasant or unpleasant feelings) and decision frames (gains or losses) in risk taking in a 20-day stock investment simulation in which 101 participants rated their current feelings while making investment decisions. As predicted, affect attenuated the relationships between decision frames and risk taking. After experiencing losses, individuals made more risky choices, in keeping with the framing effect. However, this tendency decreased and/or disappeared when loss was simultaneously experienced with either pleasant or unpleasant feelings. Similarly, individuals' tendency to avoid risk after experiencing gains disappeared or even reversed when they simultaneously experienced pleasant feelings.
Improved optical flow motion estimation for digital image stabilization
NASA Astrophysics Data System (ADS)
Lai, Lijun; Xu, Zhiyong; Zhang, Xuyao
2015-11-01
Optical flow is the instantaneous motion vector at each pixel in the image frame at a time instant. The gradient-based approach for optical flow computation can't work well when the video motion is too large. To alleviate such problem, we incorporate this algorithm into a pyramid multi-resolution coarse-to-fine search strategy. Using pyramid strategy to obtain multi-resolution images; Using iterative relationship from the highest level to the lowest level to obtain inter-frames' affine parameters; Subsequence frames compensate back to the first frame to obtain stabilized sequence. The experiment results demonstrate that the promoted method has good performance in global motion estimation.
Implementing system simulation of C3 systems using autonomous objects
NASA Technical Reports Server (NTRS)
Rogers, Ralph V.
1987-01-01
The basis of all conflict recognition in simulation is a common frame of reference. Synchronous discrete-event simulation relies on the fixed points in time as the basic frame of reference. Asynchronous discrete-event simulation relies on fixed-points in the model space as the basic frame of reference. Neither approach provides sufficient support for autonomous objects. The use of a spatial template as a frame of reference is proposed to address these insufficiencies. The concept of a spatial template is defined and an implementation approach offered. Discussed are the uses of this approach to analyze the integration of sensor data associated with Command, Control, and Communication systems.
Shelton, Rachel C; Colgrove, James; Lee, Grace; Truong, Michelle; Wingood, Gina M
2017-04-01
We conducted a content analysis of public comments to understand the key framing approaches used by private industry v. public health sector, with the goal of informing future public health messaging, framing and advocacy in the context of policy making. Comments to the proposed menu-labelling policy were extracted from Regulations.gov and analysed. A framing matrix was used to organize and code key devices and themes. Documents were analysed using content analysis with Dedoose software. Recent national nutrition-labelling regulations in the USA provide a timely opportunity to understand message framing in relation to obesity prevention and policy. We examined a total of ninety-seven documents submitted on behalf of organizations (private industry, n 64; public health, n 33). Public health focused on positive health consequences of the policy, used a social justice frame and supported its arguments with academic data. Industry was more critical of the policy; it used a market justice frame that emphasized minimal regulation, depicted its members as small, family-run businesses, and illustrated points with humanizing examples. Public health framing should counter and consider engaging directly with non-health-related arguments made by industry. Public health should include more powerful framing devices to convey their messages, including metaphors and humanizing examples.
Heiz, J; Majerus, S; Barisnikov, K
2017-09-28
This study examined the spontaneous use of allocentric and egocentric frames of reference and their flexible use as a function of instructions. The computerized spatial reference task created by Heiz and Barisnikov (2015) was used. Participants had to choose a frame of reference according to three types of instructions: spontaneous, allocentric and egocentric. The performances of 16 Williams Syndrome participants between 10 and 41 years were compared to those of two control groups (chronological age and non-verbal intellectual ability). The majority of Williams Syndrome participants did not show a preference for a particular frame of reference. When explicitly inviting participants to use an allocentric frame of reference, all three groups showed an increased use of the allocentric frame of reference. At the same time, an important heterogeneity of type of frame of reference used by Williams Syndrome participants was observed. Results demonstrate that despite difficulties in the spontaneous use of allocentric and egocentric frames of reference, some Williams Syndrome participants show flexibility in the use of an allocentric frame of reference when an explicit instruction is provided. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Informative-frame filtering in endoscopy videos
NASA Astrophysics Data System (ADS)
An, Yong Hwan; Hwang, Sae; Oh, JungHwan; Lee, JeongKyu; Tavanapong, Wallapak; de Groen, Piet C.; Wong, Johnny
2005-04-01
Advances in video technology are being incorporated into today"s healthcare practice. For example, colonoscopy is an important screening tool for colorectal cancer. Colonoscopy allows for the inspection of the entire colon and provides the ability to perform a number of therapeutic operations during a single procedure. During a colonoscopic procedure, a tiny video camera at the tip of the endoscope generates a video signal of the internal mucosa of the colon. The video data are displayed on a monitor for real-time analysis by the endoscopist. Other endoscopic procedures include upper gastrointestinal endoscopy, enteroscopy, bronchoscopy, cystoscopy, and laparoscopy. However, a significant number of out-of-focus frames are included in this type of videos since current endoscopes are equipped with a single, wide-angle lens that cannot be focused. The out-of-focus frames do not hold any useful information. To reduce the burdens of the further processes such as computer-aided image processing or human expert"s examinations, these frames need to be removed. We call an out-of-focus frame as non-informative frame and an in-focus frame as informative frame. We propose a new technique to classify the video frames into two classes, informative and non-informative frames using a combination of Discrete Fourier Transform (DFT), Texture Analysis, and K-Means Clustering. The proposed technique can evaluate the frames without any reference image, and does not need any predefined threshold value. Our experimental studies indicate that it achieves over 96% of four different performance metrics (i.e. precision, sensitivity, specificity, and accuracy).
High-frame-rate full-vocal-tract 3D dynamic speech imaging.
Fu, Maojing; Barlaz, Marissa S; Holtrop, Joseph L; Perry, Jamie L; Kuehn, David P; Shosted, Ryan K; Liang, Zhi-Pei; Sutton, Bradley P
2017-04-01
To achieve high temporal frame rate, high spatial resolution and full-vocal-tract coverage for three-dimensional dynamic speech MRI by using low-rank modeling and sparse sampling. Three-dimensional dynamic speech MRI is enabled by integrating a novel data acquisition strategy and an image reconstruction method with the partial separability model: (a) a self-navigated sparse sampling strategy that accelerates data acquisition by collecting high-nominal-frame-rate cone navigator sand imaging data within a single repetition time, and (b) are construction method that recovers high-quality speech dynamics from sparse (k,t)-space data by enforcing joint low-rank and spatiotemporal total variation constraints. The proposed method has been evaluated through in vivo experiments. A nominal temporal frame rate of 166 frames per second (defined based on a repetition time of 5.99 ms) was achieved for an imaging volume covering the entire vocal tract with a spatial resolution of 2.2 × 2.2 × 5.0 mm 3 . Practical utility of the proposed method was demonstrated via both validation experiments and a phonetics investigation. Three-dimensional dynamic speech imaging is possible with full-vocal-tract coverage, high spatial resolution and high nominal frame rate to provide dynamic speech data useful for phonetic studies. Magn Reson Med 77:1619-1629, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Martian Dust Devil Action in Gale Crater, Sol 1597
2017-02-27
This frame from a sequence of images shows a dust-carrying whirlwind, called a dust devil, scooting across the ground inside Gale Crater, as observed on the local summer afternoon of NASA's Curiosity Mars Rover's 1,597th Martian day, or sol (Feb. 1, 2017). Set within a broader southward view from the rover's Navigation Camera, the rectangular area outlined in black was imaged multiple times over a span of several minutes to check for dust devils. Images from the period with most activity are shown in the inset area. The images are in pairs that were taken about 12 seconds apart, with an interval of about 90 seconds between pairs. Timing is accelerated and not fully proportional in this animation. A dust devil is most evident in the 10th, 11th and 12th frames. In the first and fifth frames, dust blowing across the ground appears as pale horizontal streak. Contrast has been modified to make frame-to-frame changes easier to see. A black frame is added between repeats of the sequence. On Mars as on Earth, dust devils are whirlwinds that result from sunshine warming the ground, prompting convective rising of air that has gained heat from the ground. Observations of Martian dust devils provide information about wind directions and interaction between the surface and the atmosphere. An animation is available at http://photojournal.jpl.nasa.gov/catalog/PIA21270
Cultural background shapes spatial reference frame proclivity
Goeke, Caspar; Kornpetpanee, Suchada; Köster, Moritz; Fernández-Revelles, Andrés B.; Gramann, Klaus; König, Peter
2015-01-01
Spatial navigation is an essential human skill that is influenced by several factors. The present study investigates how gender, age, and cultural background account for differences in reference frame proclivity and performance in a virtual navigation task. Using an online navigation study, we recorded reaction times, error rates (confusion of turning axis), and reference frame proclivity (egocentric vs. allocentric reference frame) of 1823 participants. Reaction times significantly varied with gender and age, but were only marginally influenced by the cultural background of participants. Error rates were in line with these results and exhibited a significant influence of gender and culture, but not age. Participants’ cultural background significantly influenced reference frame selection; the majority of North-Americans preferred an allocentric strategy, while Latin-Americans preferred an egocentric navigation strategy. European and Asian groups were in between these two extremes. Neither the factor of age nor the factor of gender had a direct impact on participants’ navigation strategies. The strong effects of cultural background on navigation strategies without the influence of gender or age underlines the importance of socialized spatial cognitive processes and argues for socio-economic analysis in studies investigating human navigation. PMID:26073656
A novel simultaneous streak and framing camera without principle errors
NASA Astrophysics Data System (ADS)
Jingzhen, L.; Fengshan, S.; Ningwen, L.; Xiangdong, G.; Bin, H.; Qingyang, W.; Hongyi, C.; Yi, C.; Xiaowei, L.
2018-02-01
A novel simultaneous streak and framing camera with continuous access, the perfect information of which is far more important for the exact interpretation and precise evaluation of many detonation events and shockwave phenomena, has been developed. The camera with the maximum imaging frequency of 2 × 106 fps and the maximum scanning velocity of 16.3 mm/μs has fine imaging properties which are the eigen resolution of over 40 lp/mm in the temporal direction and over 60 lp/mm in the spatial direction and the framing frequency principle error of zero for framing record, and the maximum time resolving power of 8 ns and the scanning velocity nonuniformity of 0.136%~-0.277% for streak record. The test data have verified the performance of the camera quantitatively. This camera, simultaneously gained frames and streak with parallax-free and identical time base, is characterized by the plane optical system at oblique incidence different from space system, the innovative camera obscura without principle errors, and the high velocity motor driven beryllium-like rotating mirror, made of high strength aluminum alloy with cellular lateral structure. Experiments demonstrate that the camera is very useful and reliable to take high quality pictures of the detonation events.
NASA Technical Reports Server (NTRS)
Selzer, Robert H. (Inventor); Hodis, Howard N. (Inventor)
2011-01-01
A standardized acquisition methodology assists operators to accurately replicate high resolution B-mode ultrasound images obtained over several spaced-apart examinations utilizing a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time "live" ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, dynamic material properties of arterial structures, such as IMT and diameter, are measured in a standard region over successive image frames. Each frame of the sequence has its echo edge boundaries automatically determined by using the immediately prior frame's true echo edge coordinates as initial boundary conditions. Computerized echo edge recognition and tracking over multiple successive image frames enhances measurement of arterial diameter and IMT and allows for improved vascular dimension measurements, including vascular stiffness and IMT determinations.
When good is stickier than bad: Understanding gain/loss asymmetries in sequential framing effects.
Sparks, Jehan; Ledgerwood, Alison
2017-08-01
Considerable research has demonstrated the power of the current positive or negative frame to shape people's current judgments. But humans must often learn about positive and negative information as they encounter that information sequentially over time. It is therefore crucial to consider the potential importance of sequencing when developing an understanding of how humans think about valenced information. Indeed, recent work looking at sequentially encountered frames suggests that some frames can linger outside the context in which they are first encountered, sticking in the mind so that subsequent frames have a muted effect. The present research builds a comprehensive account of sequential framing effects in both the loss and the gain domains. After seeing information about a potential gain or loss framed in positive terms or negative terms, participants saw the same issue reframed in the opposing way. Across 5 studies and 1566 participants, we find accumulating evidence for the notion that in the gain domain, positive frames are stickier than negative frames for novel but not familiar scenarios, whereas in the loss domain, negative frames are always stickier than positive frames. Integrating regulatory focus theory with the literatures on negativity dominance and positivity offset, we develop a new and comprehensive account of sequential framing effects that emphasizes the adaptive value of positivity and negativity biases in specific contexts. Our findings highlight the fact that research conducted solely in the loss domain risks painting an incomplete and oversimplified picture of human bias and suggest new directions for future research. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Error framing effects on performance: cognitive, motivational, and affective pathways.
Steele-Johnson, Debra; Kalinoski, Zachary T
2014-01-01
Our purpose was to examine whether positive error framing, that is, making errors salient and cuing individuals to see errors as useful, can benefit learning when task exploration is constrained. Recent research has demonstrated the benefits of a newer approach to training, that is, error management training, that includes the opportunity to actively explore the task and framing errors as beneficial to learning complex tasks (Keith & Frese, 2008). Other research has highlighted the important role of errors in on-the-job learning in complex domains (Hutchins, 1995). Participants (N = 168) from a large undergraduate university performed a class scheduling task. Results provided support for a hypothesized path model in which error framing influenced cognitive, motivational, and affective factors which in turn differentially affected performance quantity and quality. Within this model, error framing had significant direct effects on metacognition and self-efficacy. Our results suggest that positive error framing can have beneficial effects even when tasks cannot be structured to support extensive exploration. Whereas future research can expand our understanding of error framing effects on outcomes, results from the current study suggest that positive error framing can facilitate learning from errors in real-time performance of tasks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zwan, Benjamin J., E-mail: benjamin.zwan@uon.edu.au; O’Connor, Daryl J.; King, Brian W.
2014-08-15
Purpose: To develop a frame-by-frame correction for the energy response of amorphous silicon electronic portal imaging devices (a-Si EPIDs) to radiation that has transmitted through the multileaf collimator (MLC) and to integrate this correction into the backscatter shielded EPID (BSS-EPID) dose-to-water conversion model. Methods: Individual EPID frames were acquired using a Varian frame grabber and iTools acquisition software then processed using in-house software developed inMATLAB. For each EPID image frame, the region below the MLC leaves was identified and all pixels in this region were multiplied by a factor of 1.3 to correct for the under-response of the imager tomore » MLC transmitted radiation. The corrected frames were then summed to form a corrected integrated EPID image. This correction was implemented as an initial step in the BSS-EPID dose-to-water conversion model which was then used to compute dose planes in a water phantom for 35 IMRT fields. The calculated dose planes, with and without the proposed MLC transmission correction, were compared to measurements in solid water using a two-dimensional diode array. Results: It was observed that the integration of the MLC transmission correction into the BSS-EPID dose model improved agreement between modeled and measured dose planes. In particular, the MLC correction produced higher pass rates for almost all Head and Neck fields tested, yielding an average pass rate of 99.8% for 2%/2 mm criteria. A two-sample independentt-test and fisher F-test were used to show that the MLC transmission correction resulted in a statistically significant reduction in the mean and the standard deviation of the gamma values, respectively, to give a more accurate and consistent dose-to-water conversion. Conclusions: The frame-by-frame MLC transmission response correction was shown to improve the accuracy and reduce the variability of the BSS-EPID dose-to-water conversion model. The correction may be applied as a preprocessing step in any pretreatment portal dosimetry calculation and has been shown to be beneficial for highly modulated IMRT fields.« less
SU-F-T-638: Is There A Need For Immobilization in SRS?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masterova, K; Sethi, A; Anderson, D
2016-06-15
Purpose: Frameless Stereotactic radiosurgery (SRS) is increasingly used in the clinic. Cone-Beam CT (CBCT) to simulation-CT match has replaced the 3-dimensional coordinate based set up using a stereotactic localizing frame. The SRS frame however served as both a localizing and immobilizing device. We seek to measure the quality of frameless (mask based) and frame based immobilization and evaluate its impact on target dose. Methods: Each SRS patient was set up by kV on-board imaging (OBI) and then fine-tuned with CBCT. A second CBCT was done at treatment-end to ascertain intrafraction motion. We compared pre- vs post-treatment CBCT shifts for bothmore » frameless and frame based SRS patients. CBCT to sim-CT fusion was repeated for each patient off-line to assess systematic residual image registration error. Each patient was re-planned with measured shifts to assess effects on target dose. Results: We analyzed 11 patients (12 lesions) treated with frameless SRS and 6 patients (11 lesions) with a fixed frame system. Average intra-fraction iso-center positioning errors for frameless and frame-based treatments were 1.24 ± 0.57 mm and 0.28 ± 0.08 mm (mean ± s.d.) respectively. Residual error in CBCT registration was 0.24 mm. The frameless positioning uncertainties led to target dose errors in Dmin and D95 of 15.5 ± 18.4% and 6.6 ± 9.1% respectively. The corresponding errors in fixed frame SRS were much lower with Dmin and D95 reduced by 4.2 ± 6.5% and D95 2.5 ± 3.8% respectively. Conclusion: Frameless mask provides good immobilization with average patient motion of 1.2 mm during treatment. This exceeds MRI voxel dimensions (∼0.43mm) used for target delineation. Frame-based SRS provides superior patient immobilization with measureable movement no greater than the background noise of the CBCT registration. Small lesions requiring submm precision are better served with a frame based SRS.« less
Rakvongthai, Yothin; Ouyang, Jinsong; Guerin, Bastien; Li, Quanzheng; Alpert, Nathaniel M.; El Fakhri, Georges
2013-01-01
Purpose: Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach. Methods: Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach. Results: At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%–29% and 32%–70% for 50 × 106 and 10 × 106 detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40–50 iterations), while more than 500 iterations were needed for CG. Conclusions: The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method. PMID:24089922
Estimated SLR station position and network frame sensitivity to time-varying gravity
NASA Astrophysics Data System (ADS)
Zelensky, Nikita P.; Lemoine, Frank G.; Chinn, Douglas S.; Melachroinos, Stavros; Beckley, Brian D.; Beall, Jennifer Wiser; Bordyugov, Oleg
2014-06-01
This paper evaluates the sensitivity of ITRF2008-based satellite laser ranging (SLR) station positions estimated weekly using LAGEOS-1/2 data from 1993 to 2012 to non-tidal time-varying gravity (TVG). Two primary methods for modeling TVG from degree-2 are employed. The operational approach applies an annual GRACE-derived field, and IERS recommended linear rates for five coefficients. The experimental approach uses low-order/degree coefficients estimated weekly from SLR and DORIS processing of up to 11 satellites (tvg4x4). This study shows that the LAGEOS-1/2 orbits and the weekly station solutions are sensitive to more detailed modeling of TVG than prescribed in the current IERS standards. Over 1993-2012 tvg4x4 improves SLR residuals by 18 % and shows 10 % RMS improvement in station stability. Tests suggest that the improved stability of the tvg4x4 POD solution frame may help clarify geophysical signals present in the estimated station position time series. The signals include linear and seasonal station motion, and motion of the TRF origin, particularly in Z. The effect on both POD and the station solutions becomes increasingly evident starting in 2006. Over 2008-2012, the tvg4x4 series improves SLR residuals by 29 %. Use of the GRGS RL02 series shows similar improvement in POD. Using tvg4x4, secular changes in the TRF origin Z component double over the last decade and although not conclusive, it is consistent with increased geocenter rate expected due to continental ice melt. The test results indicate that accurate modeling of TVG is necessary for improvement of station position estimation using SLR data.
Regenerate bone fracture rate following femoral lengthening in paediatric patients
Burke, N. G.; Cassar-Gheiti, A. J.; Tan, J.; McHugh, G.; O’Neil, B. J.; Noonan, M.; Moore, D.
2017-01-01
Abstract Purpose Femoral lengthening using a circular or mono-lateral frame is a commonly used technique. Fracture at the site of the regenerate bone is a major concern especially following removal of the external fixator. This aim of this study was to assess the rate of fracture of the regenerate bone in this single surgeon series of paediatric patients and determine potential risk factors. Methods Retrospective review of all the femoral lengthening performed by the senior author was performed. The medical and physiotherapy notes were reviewed. The gender, age at time of surgery, disease aetiology, total days in the external fixator and length of the new regenerate bone were recorded. Patients who sustained a regenerate fracture were identified. Results A total of 176 femoral lengthening procedures were performed on 108 patients. Eight regenerate fractures occurred in seven patients (4.5%). The mechanism of injury was a fall in five cases and during physiotherapy in three cases. The regenerate fracture occurred a median number of nine days following removal of frame. There was no significant difference between gender, age at time of surgery, total time in external fixator between those who sustained a regenerate fracture and those patients who did not. A significant difference was noted between the amount of lengthening between the ‘regenerate fracture group’ and the ‘no fracture group’ (50 mm vs 38 mm, respectively; p = 0.029). There was no association between disease aetiology and risk of regenerate fracture. Conclusions Femoral lengthening of more than 50 mm increases the risk of a fracture at the regenerate site regardless of the disease aetiology. We recommend avoidance of aggressive physiotherapy for the initial four weeks following external fixator removal. PMID:28828065
NChina16: A stable geodetic reference frame for geological hazard studies in north China
NASA Astrophysics Data System (ADS)
Wang, G.; Yan, B.; Gan, W.; Geng, J.
2017-12-01
This study established a stable North China Reference Frame 2016 (NChina16) using five years of continuous GPS observations (2011.8 to 2016.8) from 12 continuously operating reference stations (CORS) fixed to the stable interior of the North China Craton. Applications of NChina16 in landslide, subsidence, and post-seismic displacement studies are illustrated. The primary result of this study is the seven parameters for transforming Cartesian ECEF (Earth-Centered, Earth-Fixed) coordinates X, Y, and Z from the International GNSS Service Reference Frame 2008 (IGS08) to NChina16. The seven parameters include the epoch that is used to tie the regional reference frame to IGS08 and the time derivatives of three translations and three rotations. A method for developing a regional geodetic reference frame is introduced in detail. The GIPSY-OASIS (V6.4) software package was used to obtain the precise point positioning (PPP) time series with respect to IGS08. The stability (accuracy) of NChina16 is about 0.5 mm/year in both vertical and horizontal directions. This study also developed a regional seasonal model for correcting vertical displacement time series data derived from the PPP solutions. Long-term GPS observations (1999-2016) from five CORS in north China were used to develop the seasonal model. According to this study, the PPP daily solutions with respect to NChina16 could achieve 2-3 mm horizontal accuracy and 4-5 mm vertical accuracy after being modified by the regional model. NChina16 will be critical to the long-term landslide, subsidence, fault, and structural monitoring in north China and for ongoing post-seismic crustal deformation studies in Japan. NChina16 will be incrementally improved and synchronized with the IGS reference frame update.
NASA Astrophysics Data System (ADS)
Trusiak, M.; Patorski, K.; Tkaczyk, T.
2014-12-01
We propose a fast, simple and experimentally robust method for reconstructing background-rejected optically-sectioned microscopic images using two-shot structured illumination approach. Innovative data demodulation technique requires two grid-illumination images mutually phase shifted by π (half a grid period) but precise phase displacement value is not critical. Upon subtraction of the two frames the input pattern with increased grid modulation is computed. The proposed demodulation procedure comprises: (1) two-dimensional data processing based on the enhanced, fast empirical mode decomposition (EFEMD) method for the object spatial frequency selection (noise reduction and bias term removal), and (2) calculating high contrast optically-sectioned image using the two-dimensional spiral Hilbert transform (HS). The proposed algorithm effectiveness is compared with the results obtained for the same input data using conventional structured-illumination (SIM) and HiLo microscopy methods. The input data were collected for studying highly scattering tissue samples in reflectance mode. In comparison with the conventional three-frame SIM technique we need one frame less and no stringent requirement on the exact phase-shift between recorded frames is imposed. The HiLo algorithm outcome is strongly dependent on the set of parameters chosen manually by the operator (cut-off frequencies for low-pass and high-pass filtering and η parameter value for optically-sectioned image reconstruction) whereas the proposed method is parameter-free. Moreover very short processing time required to efficiently demodulate the input pattern predestines proposed method for real-time in-vivo studies. Current implementation completes full processing in 0.25s using medium class PC (Inter i7 2,1 GHz processor and 8 GB RAM). Simple modification employed to extract only first two BIMFs with fixed filter window size results in reducing the computing time to 0.11s (8 frames/s).
All-optical framing photography based on hyperspectral imaging method
NASA Astrophysics Data System (ADS)
Liu, Shouxian; Li, Yu; Li, Zeren; Chen, Guanghua; Peng, Qixian; Lei, Jiangbo; Liu, Jun; Yuan, Shuyun
2017-02-01
We propose and experimentally demonstrate a new all optical-framing photography that uses hyperspectral imaging methods to record a chirped pulse's temporal-spatial information. This proposed method consists of three parts: (1) a chirped laser pulse encodes temporal phenomena onto wavelengths; (2) a lenslet array generates a series of integral pupil images;(3) a dispersive device disperses the integral images at void space of image sensor. Compared with Ultrafast All-Optical Framing Technology(Daniel Frayer,2013,2014) and Sequentially Time All-Optical Mapping Photography( Nakagawa 2014, 2015), our method is convenient to adjust the temporal resolution and to flexibly increase the numbers of frames. Theoretically, the temporal resolution of our scheme is limited by the amount of dispersion that is added to a Fourier transform limited femtosecond laser pulse. Correspondingly, the optimal number of frames is decided by the ratio of the observational time window to the temporal resolution, and the effective pixels of each frame are mostly limited by the dimensions M×N of the lenslet array. For example, if a 40fs Fourier transform limited femtosecond pulse is stretched to 10ps, a CCD camera with 2048×3072 pixels can record 15 framing images with temporal resolution of 650fs and image size of 100×100 pixels. As spectrometer structure, our recording part has another advantage that not only amplitude images but also frequency domain interferograms can be imaged. Therefore, it is comparatively easy to capture fast dynamics in the refractive index change of materials. A further dynamic experiment is being conducted.
Huang, Chenyu; Ogawa, Rei; Hyakusoku, Hiko
2014-08-01
The current skin graft fixation methods for digits, including the Kirschner wire insertion technique, can be limited by inadequate or excessive fixation and complications such as infection or secondary injuries. Therefore, the external wire-frame fixation method was invented and used for skin grafting of digits. This study aimed to investigate external wire-frame fixation of digital skin grafts as a non-invasive alternative to the K-wire insertion method. In 2005-2012, 15 patients with burn scar contractures on the hand digits received a skin graft that was then fixed with an external wire frame. The intra-operative time needed to make the wire frame, the postoperative time to frame and suture removal, the graft survival rate, the effect of contracture release and the complications were recorded. In all cases, the contracture release was 100%. The complete graft survival rate was 98.6%. Four patients had epithelial necrosis in <5% of the total area. There were no other complications such as pressure ulcer or hypoxia of fingers. External wire-frame fixation is simple, minimally invasive and a custom-made technique for skin grafting of the fingers. It was designed for its potential benefits and the decreased risk it poses to patients with scar contractures on their fingers. It can be implemented in three phases of grafting, does not affect the epiphyseal line or subsequent finger growth and is suitable for children with multi-digit involvement. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
Lebel, Karina; Boissy, Patrick; Hamel, Mathieu; Duval, Christian
2015-01-01
Background Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. Methods This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. Findings Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. Interpretation The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. Conclusions Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their full potential in capturing clinical outcomes. PMID:25811838
Effect of semen preparation on casa motility results in cryopreserved bull spermatozoa.
Contri, Alberto; Valorz, Claudio; Faustini, Massimo; Wegher, Laura; Carluccio, Augusto
2010-08-01
Computer-assisted sperm analyzers (CASA) have become the standard tool for evaluating sperm motility and kinetic patterns because they provide objective data for thousands of sperm tracks. However, these devices are not ready-to-use and standardization of analytical practices is a fundamental requirement. In this study, we evaluated the effects of some settings, such as frame rate and frames per field, chamber and time of analysis, and samples preparations, including thawing temperature, sperm sample concentration, and media used for dilution, on the kinetic results of bovine frozen-thawed semen using a CASA. In Experiment 1, the frame rate (30-60 frame/s) significantly affected motility parameters, whereas the number of frames per field (30 or 45) did not seem to affect sperm kinetics. In Experiment 2, the thawing protocol affects sperm motility and kinetic parameters. Sperm sample concentration significantly limited the opportunity to perform the analysis and the kinetic results. A concentration of 100 and 50 x 10(6) sperm/mL limited the device's ability to perform the analysis or gave wrong results, whereas 5, 10, 20, and 30 x 10(6) sperm/mL concentrations allowed the analysis to be performed, but with different results (Experiment 3). The medium used for the dilution of the sample, which is fundamental for a correct sperm head detection, affects sperm motility results (Experiment 4). In this study, Makler and Leja chambers were used to perform the semen analysis with CASA devices. The chamber used significantly affected motility results (Experiment 5). The time between chamber loading and analysis affected sperm velocities, regardless of chamber used. Based on results recorded in this study, we propose that the CASA evaluation of motility of bovine frozen-thawed semen using Hamilton-Thorne IVOS 12.3 should be performed using a frame rate of 60 frame/s and 30 frames per field. Semen should be diluted at least at 20 x 10(6) sperm/mL using PBS. Furthermore, it is necessary to consider the type of chamber used and perform the analysis within 1 or 2 min, regardless of the chamber used. Copyright 2010 Elsevier Inc. All rights reserved.
Consistency in infants’ behavioral signaling of satiation during bottle-feeding
Ventura, Alison K.; Inamdar, Loma B.; Mennella, Julie A.
2014-01-01
Objectives Understanding the dynamics of feeding is essential for preventing accelerated weight gain during infancy, a risk factor for obesity. Because infants satiate on larger volumes of cow milk formula (CMF) than CMF enriched with the free amino acid glutamate (CMF+glu), we used this model system to determine whether infants displayed consistent behaviors despite satiating on lower volumes. Methods In this laboratory-based, within-subject experimental study of ≤4-month-old infants (N=41) and their mothers, infants were videotaped while feeding to satiation CMF on one test day and CMF+glu on the other, in counterbalanced order. Each video-recording was analyzed frame-by-frame for frequency and timing of behaviors. Results Infants’ behaviors were consistent in types and frequency but were displayed sooner when feeding CMF+glu compared with CMF. The less responsive the mother’s feeding style, the less consistently the infant displayed behaviors across the two formula meals (p=0.05). Infants who spat up (a possible sign of overfeeding) consumed more formula (p=0.01) and had less responsive mothers (p=0.04) compared with the other infants. Conclusions Infants are consistent in their behavioral displays during feeding at this developmental age. Regulation of intake and signaling of satiation during bottle-feeding are associated with formula composition and maternal feeding style. PMID:24990443
Code of Federal Regulations, 2010 CFR
2010-01-01
... technology. At the conclusion of his speech, the association presents the employee a framed map with a market value of $18 and a book about the history of cartography with a market value of $15. The employee may... employee. Relevant factors in making such a determination include the history of the relationship and...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadri, Keyvan, E-mail: keyvan.sadri@pci.uni-heidelberg.de; Meyer, Hans-Dieter, E-mail: hans-dieter.meyer@pci.uni-heidelberg.de; Lauvergnat, David, E-mail: david.lauvergnat@u-psud.fr
2014-09-21
For computational rovibrational spectroscopy the choice of the frame is critical for an approximate separation of overall rotation from internal motions. To minimize the coupling between internal coordinates and rotation, Eckart proposed a condition [“Some studies concerning rotating axes and polyatomic molecules,” Phys. Rev. 47, 552–558 (1935)] and a frame that fulfills this condition is hence called an Eckart frame. A method is developed to introduce in a systematic way the Eckart frame for the expression of the kinetic energy operator (KEO) in the polyspherical approach. The computed energy levels of a water molecule are compared with those obtained usingmore » a KEO in the standard definition of the Body-fixed frame of the polyspherical approach. The KEO in the Eckart frame leads to a faster convergence especially for large J states and vibrationally excited states. To provide an example with more degrees of freedom, rotational states of the vibrational ground state of the trans nitrous acid (HONO) are also investigated.« less
GPU-Based Real-Time Volumetric Ultrasound Image Reconstruction for a Ring Array
Choe, Jung Woo; Nikoozadeh, Amin; Oralkan, Ömer; Khuri-Yakub, Butrus T.
2014-01-01
Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense computational load required in synthetic beamforming. For fast imaging with a ring array, we developed graphics processing unit (GPU)-based, real-time image reconstruction software that exploits massive data-level parallelism in beamforming operations. The GPU-based software reconstructs and displays three cross-sectional images at 45 frames per second (fps). This frame rate is 4.5 times higher than that for our previously-developed multi-core CPU-based software. In an alternative imaging mode, it shows one B-mode image rotating about the axis and its maximum intensity projection (MIP), processed at a rate of 104 fps. This paper describes the image reconstruction procedure on the GPU platform and presents the experimental images obtained using this software. PMID:23529080
Smoking Cessation Apps for Smartphones: Content Analysis With the Self-Determination Theory
Noh, Ghee-Young; Park, Dong-Jin
2014-01-01
Background Smartphones are increasingly receiving attention from public health scholars and practitioners as a means to assist individuals’ health management. A number of smartphone apps for smoking cessation are also available; however, little effort has been made to evaluate the content and functions of these apps employing a theoretical framework. Objective The present study aims to analyze and evaluate the contents of smoking cessation apps available in South Korea employing the self-determination theory (SDT) as a theoretical framework for analysis. This study analyzes the extent to which smoking cessation apps have features that satisfy the basic needs identified in the SDT, which stimulate autonomous motivation. The type of motivational goal content manifested in the apps and how the goal content was framed are also explored. By assessing the features of smoking cessation apps based on the SDT, this study aims to offer direction for improvement for these apps. Methods Out of 309 apps identified from the iTunes store and Google Play (excluding 27 duplications), 175 apps were randomly drawn and analyzed. The coding scheme was drafted by the authors based on the SDT and gain/loss framing theory and was further finely tuned through the process of coder training and by establishing intercoder reliability. Once the intercoder reliability was established, the coders divided up the rest of the sample and coded them independently. Results The analysis revealed that most apps (94.3%, 165/175) had at least one feature that tapped at least 1 of the 3 basic needs. Only 18 of 175 apps (10.3%) addressed all 3 basic needs. For goal content, money (53.7%, 94/175) showed the highest frequency, followed by health (32.0%, 56/175), time (7.4%, 13/175), and appearance (1.1%, 2/175), suggesting that extrinsic goals are more dominantly presented in smoking cessation apps. For the framing of goal content, gain framing appeared more frequently (41.7%, 73/175). Conclusions The results suggest that these smoking cessation apps may not sufficiently stimulate autonomous motivation; a small number of apps addressed all 3 basic needs suggested by the SDT (ie, autonomy, competence, and relatedness). The apps also tended to present extrinsic goal content (primarily in terms of money) over intrinsic ones (ie, health) by primarily adopting gain framing. Implications of these findings for public health practitioners and consumers are discussed. PMID:24521881
Feature Tracking for High Speed AFM Imaging of Biopolymers.
Hartman, Brett; Andersson, Sean B
2018-03-31
The scanning speed of atomic force microscopes continues to advance with some current commercial microscopes achieving on the order of one frame per second and at least one reaching 10 frames per second. Despite the success of these instruments, even higher frame rates are needed with scan ranges larger than are currently achievable. Moreover, there is a significant installed base of slower instruments that would benefit from algorithmic approaches to increasing their frame rate without requiring significant hardware modifications. In this paper, we present an experimental demonstration of high speed scanning on an existing, non-high speed instrument, through the use of a feedback-based, feature-tracking algorithm that reduces imaging time by focusing on features of interest to reduce the total imaging area. Experiments on both circular and square gratings, as well as silicon steps and DNA strands show a reduction in imaging time by a factor of 3-12 over raster scanning, depending on the parameters chosen.
Real-time motion-based H.263+ frame rate control
NASA Astrophysics Data System (ADS)
Song, Hwangjun; Kim, JongWon; Kuo, C.-C. Jay
1998-12-01
Most existing H.263+ rate control algorithms, e.g. the one adopted in the test model of the near-term (TMN8), focus on the macroblock layer rate control and low latency under the assumptions of with a constant frame rate and through a constant bit rate (CBR) channel. These algorithms do not accommodate the transmission bandwidth fluctuation efficiently, and the resulting video quality can be degraded. In this work, we propose a new H.263+ rate control scheme which supports the variable bit rate (VBR) channel through the adjustment of the encoding frame rate and quantization parameter. A fast algorithm for the encoding frame rate control based on the inherent motion information within a sliding window in the underlying video is developed to efficiently pursue a good tradeoff between spatial and temporal quality. The proposed rate control algorithm also takes the time-varying bandwidth characteristic of the Internet into account and is able to accommodate the change accordingly. Experimental results are provided to demonstrate the superior performance of the proposed scheme.
NASA Technical Reports Server (NTRS)
Zhu, S. Y.; Mueller, I. I.
1982-01-01
The effect of adopting definitive precession and equinox corrections on the terrestrial reference frame was investigated. It is noted that the effect on polar motion is a diurnal periodic term with an amplitude increasing linearly in time whole on UT1 it is a linear term: general principles are given to determine the effects of small rotations of the frame of a conventional inertial reference system (CIS) on the frame of the conventional terrestrial reference system (CTS); seven CTS options are presented, one of which is necessary to accommodate such rotation. Accommodating possible future changes in the astronomical nutation is discussed. The effects of differences which may exist between the various CTS's and CIS's on Earth rotation parameters (ERP) and how these differences can be determined are examined. It is shown that the CTS differences can be determined from observations made at the same site. The CIS differences by comparing the ERP's are determined by the different techniques during the same time period.
NASA Technical Reports Server (NTRS)
Zhu, S. Y.; Mueller, I. I.
1982-01-01
The effects of adopting new definitive precession and equinox corrections on the terrestrial reference frame was investigated. It is noted that: (1) the effect on polar motion is a diurnal periodic term with an amplitude increasing linearly in time whole on UT1 it is a linear term; (2) general principles are given to determine the effects of small rotations of the frame of a conventional inertial reference system (CIS) on the frame of the conventional terrestrial reference system (CTS); (3) seven CTS options are presented, one of which is necessary to accommodate such rotation. Accommodating possible future changes in the astronomical nutation is discussed. The effects of differences which may exist between the various CTS's and CIS's on Earth rotation parameters (ERP) and how these differences can be determined are examined. It is shown that the CTS differences can be determined from observations made at the same site, while the CIS differences by comparing the ERP's determined by the different techniques during the same time period.
NASA Technical Reports Server (NTRS)
Hooke, A. J.
1979-01-01
A set of standard telemetry protocols for downlink data flow facilitating the end-to-end transport of instrument data from the spacecraft to the user in real time is proposed. The direct switching of data by autonomous message 'packets' that are assembled by the source instrument on the spacecraft is discussed. The data system consists thus of a format on a message rather than word basis, and such packet telemetry would include standardized protocol headers. Standards are being developed within the NASA End-to-End Data System (NEEDS) program for the source packet and transport frame protocols. The source packet protocol contains identification of both the sequence number of the packet as it is generated by the source and the total length of the packet, while the transport frame protocol includes a sequence count defining the serial number of the frame as it is generated by the spacecraft data system, and a field specifying any 'options' selected in the format of the frame itself.
ERIC Educational Resources Information Center
Chiesi, Francesca; Ciancaleoni, Matteo; Galli, Silvia; Primi, Caterina
2012-01-01
This article is aimed at evaluating the possibility that Set I of the Advanced Progressive Matrices (APM-Set I) can be employed to assess fluid ability in a short time frame. The APM-Set I was administered to a sample of 1,389 primary and secondary school students. Confirmatory factor analysis attested to the unidimensionality of the scale. Item…
Autocorrelation of location estimates and the analysis of radiotracking data
Otis, D.L.; White, Gary C.
1999-01-01
The wildlife literature has been contradictory about the importance of autocorrelation in radiotracking data used for home range estimation and hypothesis tests of habitat selection. By definition, the concept of a home range involves autocorrelated movements, but estimates or hypothesis tests based on sampling designs that predefine a time frame of interest, and that generate representative samples of an animal's movement during this time frame, should not be affected by length of the sampling interval and autocorrelation. Intensive sampling of the individual's home range and habitat use during the time frame of the study leads to improved estimates for the individual, but use of location estimates as the sample unit to compare across animals is pseudoreplication. We therefore recommend against use of habitat selection analysis techniques that use locations instead of individuals as the sample unit. We offer a general outline for sampling designs for radiotracking studies.
NASA Technical Reports Server (NTRS)
Ponseggi, B. G. (Editor); Johnson, H. C. (Editor)
1985-01-01
Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.
Machine learning for cardiac ultrasound time series data
NASA Astrophysics Data System (ADS)
Yuan, Baichuan; Chitturi, Sathya R.; Iyer, Geoffrey; Li, Nuoyu; Xu, Xiaochuan; Zhan, Ruohan; Llerena, Rafael; Yen, Jesse T.; Bertozzi, Andrea L.
2017-03-01
We consider the problem of identifying frames in a cardiac ultrasound video associated with left ventricular chamber end-systolic (ES, contraction) and end-diastolic (ED, expansion) phases of the cardiac cycle. Our procedure involves a simple application of non-negative matrix factorization (NMF) to a series of frames of a video from a single patient. Rank-2 NMF is performed to compute two end-members. The end members are shown to be close representations of the actual heart morphology at the end of each phase of the heart function. Moreover, the entire time series can be represented as a linear combination of these two end-member states thus providing a very low dimensional representation of the time dynamics of the heart. Unlike previous work, our methods do not require any electrocardiogram (ECG) information in order to select the end-diastolic frame. Results are presented for a data set of 99 patients including both healthy and diseased examples.
Condition sensor system and method
NASA Technical Reports Server (NTRS)
Polhemus, J. T.; Morgan, J. E.; Mandell, A. (Inventor)
1978-01-01
The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.
NASA Astrophysics Data System (ADS)
Willis, Andrew R.; Brink, Kevin M.
2016-06-01
This article describes a new 3D RGBD image feature, referred to as iGRaND, for use in real-time systems that use these sensors for tracking, motion capture, or robotic vision applications. iGRaND features use a novel local reference frame derived from the image gradient and depth normal (hence iGRaND) that is invariant to scale and viewpoint for Lambertian surfaces. Using this reference frame, Euclidean invariant feature components are computed at keypoints which fuse local geometric shape information with surface appearance information. The performance of the feature for real-time odometry is analyzed and its computational complexity and accuracy is compared with leading alternative 3D features.
Integrating Analysis Goals for EOP, CRF and TRF
NASA Technical Reports Server (NTRS)
Ma, Chopo; MacMillan, Daniel; Petrov, Leonid
2002-01-01
In a simplified, idealized way the TRF (Terrestrial Reference Frame) can be considered a set of positions at epoch and corresponding linear rates of change while the CRF (Celestial Reference Frame) is a set of fixed directions in space. VLBI analysis can be optimized for CRF and TRF separately while handling some of the complexity of geodetic and astrometric reality. For EOP (Earth Orientation Parameter) time series both CRF and TRF should be accurate at the epoch of interest and well defined over time. The optimal integration of EOP, TRF and CRF in a single VLBI solution configuration requires a detailed consideration of the data set and the possibly conflicting nature of the reference frames. A possible approach for an integrated analysis is described.
Unsupervised Framework to Monitor Lake Dynamics
NASA Technical Reports Server (NTRS)
Chen, Xi C. (Inventor); Boriah, Shyam (Inventor); Khandelwal, Ankush (Inventor); Kumar, Vipin (Inventor)
2016-01-01
A method of reducing processing time when assigning geographic areas to land cover labels using satellite sensor values includes a processor receiving a feature value for each pixel in a time series of frames of satellite sensor values, each frame containing multiple pixels and each frame covering a same geographic location. For each sub-area of the geographic location, the sub-area is assigned to one of at least three land cover labels. The processor determines a fraction function for a first sub-area assigned to a first land cover label. The sub-areas that were assigned to the first land cover label are reassigned to one of the second land cover label and the third land cover label based on the fraction functions of the sub-areas.
Methods and apparatus for non-acoustic speech characterization and recognition
Holzrichter, John F.
1999-01-01
By simultaneously recording EM wave reflections and acoustic speech information, the positions and velocities of the speech organs as speech is articulated can be defined for each acoustic speech unit. Well defined time frames and feature vectors describing the speech, to the degree required, can be formed. Such feature vectors can uniquely characterize the speech unit being articulated each time frame. The onset of speech, rejection of external noise, vocalized pitch periods, articulator conditions, accurate timing, the identification of the speaker, acoustic speech unit recognition, and organ mechanical parameters can be determined.
Methods and apparatus for non-acoustic speech characterization and recognition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holzrichter, J.F.
By simultaneously recording EM wave reflections and acoustic speech information, the positions and velocities of the speech organs as speech is articulated can be defined for each acoustic speech unit. Well defined time frames and feature vectors describing the speech, to the degree required, can be formed. Such feature vectors can uniquely characterize the speech unit being articulated each time frame. The onset of speech, rejection of external noise, vocalized pitch periods, articulator conditions, accurate timing, the identification of the speaker, acoustic speech unit recognition, and organ mechanical parameters can be determined.
van den Akker, O B A; Purewal, S
2011-12-01
This study tested the effectiveness of the framing effect and fear appeals to inform young people about the risks of multiple births and the option of selecting elective single-embryo transfer (eSET). A non-patient student sample (age (mean±SD) 23±5.5 years; n=321) were randomly allocated to one of seven groups: (1) framing effect: (1a) gain and (1b) loss frame; (2) fear appeal: (2a) high, (2b) medium and (2c) low fear; or (3) a control group: (3a) education and (3b) non-education. The primary outcome measure was the Attitudes towards Single Embryo Transfer questionnaire, before exposure to the messages (time 1) and immediately afterwards (time 2). Results revealed participants in the high fear, medium fear and gain condition demonstrated the most positive and significant differences (P<0.001 to P<0.05) in their knowledge, hypothetical intentions and modest changes in attitudes towards eSET than the low fear, loss frame and education and non-education messages. The results demonstrate that the use of complex persuasive communication techniques on a student population to promote immediate and hypothetical eSET preferences is more successful at promoting eSET than merely reporting educational content. Future research should investigate its application in a clinical population. A multiple pregnancy is a health risk to both infant and mother following IVF treatment. The aims of this study were to test the effectiveness of two persuasive communication techniques (the framing effect and fear appeals) to inform young people about the risks of multiple births and the hypothetical option of selecting elective single-embryo transfer (eSET) (i.e., only one embryo is transferred to the uterus using IVF treatment). A total of 321 non-patient student sample (mean age 23) were randomly allocated to read a message from one of seven groups: (1) framing effect: (1a) gain and (1b) loss frame; (2) fear appeal: (2a) high, (2b) medium and (2c) low fear; or (3) a control group: education (3a) and (3b) non-education. Participants completed the Attitudes towards Single Embryo Transfer questionnaire, before exposure to the messages (time 1) and immediately afterwards (time 2). Results revealed that participants in the high fear, medium fear and gain condition demonstrated the most positive and significant differences in their knowledge, hypothetical intentions and modest changes in attitudes towards eSET than the low fear, loss frame and education and non-education messages. This study recommends that health promotion based on the framing effect and fear appeals should be tested in clinical (patient) samples in the future. Copyright © 2011 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
Experimental comparison of high-density scintillators for EMCCD-based gamma ray imaging
NASA Astrophysics Data System (ADS)
Heemskerk, Jan W. T.; Kreuger, Rob; Goorden, Marlies C.; Korevaar, Marc A. N.; Salvador, Samuel; Seeley, Zachary M.; Cherepy, Nerine J.; van der Kolk, Erik; Payne, Stephen A.; Dorenbos, Pieter; Beekman, Freek J.
2012-07-01
Detection of x-rays and gamma rays with high spatial resolution can be achieved with scintillators that are optically coupled to electron-multiplying charge-coupled devices (EMCCDs). These can be operated at typical frame rates of 50 Hz with low noise. In such a set-up, scintillation light within each frame is integrated after which the frame is analyzed for the presence of scintillation events. This method allows for the use of scintillator materials with relatively long decay times of a few milliseconds, not previously considered for use in photon-counting gamma cameras, opening up an unexplored range of dense scintillators. In this paper, we test CdWO4 and transparent polycrystalline ceramics of Lu2O3:Eu and (Gd,Lu)2O3:Eu as alternatives to currently used CsI:Tl in order to improve the performance of EMCCD-based gamma cameras. The tested scintillators were selected for their significantly larger cross-sections at 140 keV (99mTc) compared to CsI:Tl combined with moderate to good light yield. A performance comparison based on gamma camera spatial and energy resolution was done with all tested scintillators having equal (66%) interaction probability at 140 keV. CdWO4, Lu2O3:Eu and (Gd,Lu)2O3:Eu all result in a significantly improved spatial resolution over CsI:Tl, albeit at the cost of reduced energy resolution. Lu2O3:Eu transparent ceramic gives the best spatial resolution: 65 µm full-width-at-half-maximum (FWHM) compared to 147 µm FWHM for CsI:Tl. In conclusion, these ‘slow’ dense scintillators open up new possibilities for improving the spatial resolution of EMCCD-based scintillation cameras.
Fully Automatic Segmentation of Fluorescein Leakage in Subjects With Diabetic Macular Edema
Rabbani, Hossein; Allingham, Michael J.; Mettu, Priyatham S.; Cousins, Scott W.; Farsiu, Sina
2015-01-01
Purpose. To create and validate software to automatically segment leakage area in real-world clinical fluorescein angiography (FA) images of subjects with diabetic macular edema (DME). Methods. Fluorescein angiography images obtained from 24 eyes of 24 subjects with DME were retrospectively analyzed. Both video and still-frame images were obtained using a Heidelberg Spectralis 6-mode HRA/OCT unit. We aligned early and late FA frames in the video by a two-step nonrigid registration method. To remove background artifacts, we subtracted early and late FA frames. Finally, after postprocessing steps, including detection and inpainting of the vessels, a robust active contour method was utilized to obtain leakage area in a 1500-μm-radius circular region centered at the fovea. Images were captured at different fields of view (FOVs) and were often contaminated with outliers, as is the case in real-world clinical imaging. Our algorithm was applied to these images with no manual input. Separately, all images were manually segmented by two retina specialists. The sensitivity, specificity, and accuracy of manual interobserver, manual intraobserver, and automatic methods were calculated. Results. The mean accuracy was 0.86 ± 0.08 for automatic versus manual, 0.83 ± 0.16 for manual interobserver, and 0.90 ± 0.08 for manual intraobserver segmentation methods. Conclusions. Our fully automated algorithm can reproducibly and accurately quantify the area of leakage of clinical-grade FA video and is congruent with expert manual segmentation. The performance was reliable for different DME subtypes. This approach has the potential to reduce time and labor costs and may yield objective and reproducible quantitative measurements of DME imaging biomarkers. PMID:25634978
The nature of newspaper coverage of homicide
Taylor, C; Sorenson, S
2002-01-01
Objectives: Previous research has shown that some homicides are more likely than others to receive newspaper coverage (for example, homicides by strangers). The present investigation examined whether, once the decision has been made to report on a homicide, the nature of the coverage (that is, how much visibility is given to a story, what information is included, and how a story is written) differs according to two key variables, victim ethnicity, and victim-suspect relationship. Setting: Los Angeles, California (USA). Methods: Homicide articles from the 1990–94 issues of the Los Angeles Times were stratified according to the predictors of interest (victim ethnicity and victim-suspect relationship) and a sample was drawn. Data that characterized two primary aspects of newspaper coverage, prominence and story framing (including background information, story focus, use of opinions, story tone, and "hook" or leading introductory lines) were abstracted from the articles. Descriptive statistics and cross tabulations were generated. Multivariate analyses were conducted to examine the predictive value of victim ethnicity and victim-suspect relationship on the nature of the newspaper coverage. Results: Newspaper coverage of homicide was generally factual, episodic, and unemotional in tone. Victim-suspect relationship, but not victim ethnicity, was related to how a story was covered, particularly the story frame. Homicides by intimates were covered consistently differently from other types of homicides; these stories were less likely to be opinion dominated, be emotional, and begin with a "hook". Conclusion: Victim-suspect relationship was related to the nature of coverage of homicides in a large, metropolitan newspaper. Given the agenda setting and issue framing functions of the news media, these findings have implications for the manner in which the public and policy makers perceive homicides and, consequently, for the support afforded to various types of solutions for addressing and preventing violence. PMID:12120830
Heterogeneous Concurrent Modeling and Design in Java (Volume 2: Ptolemy II Software Architecture)
2008-04-01
file (EPS) suitable for inclusion in word processors. The image in figure 7.3 is such an EPS file imported into FrameMaker . At this time, the EPS...can be imported into word processors. This figure was imported into FrameMaker . 152 Ptolemy II Plot Package 7.2.4 Modifying the format You can control...FixToken class 57 FrameMaker 149 full name 4 function closures 59 function dependency 48 FunctionDependency class 48 FunctionToken 122 FunctionToken
Inertial Navigation System Aiding Using Vision
2013-03-01
abp a + Cba d dt ( pa ) + d dt ( rbba ) (2.11) vb = d dt ( rbba ) + Cba (Ω a... abp a + va) (2.12) where ddt (r b ba) accounts for the relative velocity betwwen the a-frame and b-frame, CbaΩaabp a is the instantaneous velocity of p...frame. Taking another time derivative of Eq. 2.12 results in: d dt ( vb ) , ab = d2 dt2 rbba + d dt [ Cba (Ω a abp a + va) ] (2.13) = r̈bba + dCba
2014-01-01
Background There is a huge interest by faith-based organizations (FBOs) in sub-Saharan Africa and elsewhere in HIV prevention interventions that build on the religious aspects of being. Successful partnerships between the public health services and FBOs will require a better understanding of the conceptual framing of HIV prevention by FBOS to access for prevention intervention, those concepts the churches of various denominations and their members would support or endorse. This study investigated the conceptual framing of HIV prevention among church youths in Botswana; - a country with one of the highest HIV prevalence in the world. Method Participants were 213 Pentecostal church members (67% female; age range 12 to 23 years; median age = 19 years). We engaged the participants in a mixed-method inductive process to collect data on their implicit framing of HIV prevention concepts, taking into account the centrality of religion concepts to them and the moderating influences of age, gender and sexual experience. After, we analysed the data using multi-dimensional scaling (MDS) and hierarchical cluster analysis (HCA) to map the ways the church youths framed HIV prevention. Results The findings suggest the church youth to conceptually frame their HIV prevention from both faith-oriented and secular-oriented perspectives, while prioritizing the faith-oriented concepts based on biblical teachings and future focus. In their secular-oriented framing of HIV prevention, the church youths endorsed the importance to learn the facts about HIV and AIDS, understanding of community norms that increased risk for HIV and prevention education. However, components of secular-oriented framing of HIV prevention concepts were comparatively less was well differentiated among the youths than with faith-oriented framing, suggesting latent influences of the church knowledge environment to undervalue secular oriented concepts. Older and sexually experienced church youths in their framing of HIV prevention valued future focus and prevention education less than contrasting peer cohorts, suggesting their greater relative risk for HIV infection. Conclusion A prospective HIV prevention intervention with the Pentecostal church youths would combine both faith and secular informed concepts. It also would need to take into account the ways in which these youth interpret secular-oriented health concepts in the context of their religious beliefs. PMID:24593140
NASA Astrophysics Data System (ADS)
Laurenzis, Martin; Velten, Andreas
2014-10-01
In the present paper, we discuss new approaches to analyze laser gated viewing data for non-line-of-sight vision with a novel frame-to-frame back projection as well as feature selection algorithms. While first back projection approaches use time transients for each pixel, our new method has the ability to calculate the projection of imaging data on the obscured voxel space for each frame. Further, four different data analysis algorithms were studied with the aim to identify and select signals from different target positions. A slight modification of commonly used filters leads to powerful selection of local maximum values. It is demonstrated that the choice of the filter has impact on the selectivity i.e. multiple target detection as well as on the localization precision.
Case study of a framing effect in course evaluations.
Lynöe, Niels; Juth, Niklas; Helgesson, Gert
2012-01-01
When new elements are included in the medical curriculum and the total time frame remains unchanged, established disciplines have to shorten their courses. This might bring about frustration among the teachers and students concerned, which in turn might affect how other courses are perceived. Two course evaluations, one before and one after a major change in the curriculum were compared. Comments were also analysed. We found that the students' and teachers' frustration influenced the students' evaluations of a new course in the philosophy of medicine and accordingly brought about an unintended message effect referred to as a framing effect. The results of this observational study indicate that a negative framing effect might influence course-evaluations. We suggest that this study might be used as a point of departure for further empirical studies about negative framing effects.
Meyer, Ross E.
1993-01-01
A climbing apparatus is provided for climbing ferromagnetic surfaces, such as storage tanks and steel frame structures. A magnet assembly is rotatably mounted in a frame assembly. The frame assembly provides a pair of cam surfaces having different dimensions so that, when the frame is rotated, the cam surfaces contact the ferromagnetic surface to separate the magnet assembly from the surface. The different cam dimensions enable one side of the magnet at a time to be detached from the surface to reduce the effort needed to disengage the climbing apparatus. The cam surface also provides for smoothly attaching the apparatus. A hardened dowel pin is also attached to the frame and the pointed end of the dowel engages the surface when the magnet is attached to the surface to prevent downward sliding movement of the assembly under the weight of the user.
Meyer, R.E.
1993-03-09
A climbing apparatus is provided for climbing ferromagnetic surfaces, such as storage tanks and steel frame structures. A magnet assembly is rotatably mounted in a frame assembly. The frame assembly provides a pair of cam surfaces having different dimensions so that, when the frame is rotated, the cam surfaces contact the ferromagnetic surface to separate the magnet assembly from the surface. The different cam dimensions enable one side of the magnet at a time to be detached from the surface to reduce the effort needed to disengage the climbing apparatus. The cam surface also provides for smoothly attaching the apparatus. A hardened dowel pin is also attached to the frame and the pointed end of the dowel engages the surface when the magnet is attached to the surface to prevent downward sliding movement of the assembly under the weight of the user.
Covariant Structure of Models of Geophysical Fluid Motion
NASA Astrophysics Data System (ADS)
Dubos, Thomas
2018-01-01
Geophysical models approximate classical fluid motion in rotating frames. Even accurate approximations can have profound consequences, such as the loss of inertial frames. If geophysical fluid dynamics are not strictly equivalent to Newtonian hydrodynamics observed in a rotating frame, what kind of dynamics are they? We aim to clarify fundamental similarities and differences between relativistic, Newtonian, and geophysical hydrodynamics, using variational and covariant formulations as tools to shed the necessary light. A space-time variational principle for the motion of a perfect fluid is introduced. The geophysical action is interpreted as a synchronous limit of the relativistic action. The relativistic Levi-Civita connection also has a finite synchronous limit, which provides a connection with which to endow geophysical space-time, generalizing Cartan (1923). A covariant mass-momentum budget is obtained using covariance of the action and metric-preserving properties of the connection. Ultimately, geophysical models are found to differ from the standard compressible Euler model only by a specific choice of a metric-Coriolis-geopotential tensor akin to the relativistic space-time metric. Once this choice is made, the same covariant mass-momentum budget applies to Newtonian and all geophysical hydrodynamics, including those models lacking an inertial frame. Hence, it is argued that this mass-momentum budget provides an appropriate, common fundamental principle of dynamics. The postulate that Euclidean, inertial frames exist can then be regarded as part of the Newtonian theory of gravitation, which some models of geophysical hydrodynamics slightly violate.
The Gaia inertial reference frame and the tilting of the Milky Way disk
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perryman, Michael; Spergel, David N.; Lindegren, Lennart, E-mail: mac.perryman@gmail.com
2014-07-10
While the precise relationship between the Milky Way disk and the symmetry planes of the dark matter halo remains somewhat uncertain, a time-varying disk orientation with respect to an inertial reference frame seems probable. Hierarchical structure formation models predict that the dark matter halo is triaxial and tumbles with a characteristic rate of ∼2 rad H{sub 0}{sup −1} (∼30 μas yr{sup –1}). These models also predict a time-dependent accretion of gas, such that the angular momentum vector of the disk should be misaligned with that of the halo. These effects, as well as tidal effects of the LMC, will resultmore » in the rotation of the angular momentum vector of the disk population with respect to the quasar reference frame. We assess the accuracy with which the positions and proper motions from Gaia can be referred to a kinematically non-rotating system, and show that the spin vector of the transformation from any rigid self-consistent catalog frame to the quasi-inertial system defined by quasars should be defined to better than 1 μas yr{sup –1}. Determination of this inertial frame by Gaia will reveal any signature of the disk orientation varying with time, improve models of the potential and dynamics of the Milky Way, test theories of gravity, and provide new insights into the orbital evolution of the Sagittarius dwarf galaxy and the Magellanic Clouds.« less
Distributed Fair Auto Rate Medium Access Control for IEEE 802.11 Based WLANs
NASA Astrophysics Data System (ADS)
Zhu, Yanfeng; Niu, Zhisheng
Much research has shown that a carefully designed auto rate medium access control can utilize the underlying physical multi-rate capability to exploit the time-variation of the channel. In this paper, we develop a simple analytical model to elucidate the rule that maximizes the throughput of RTS/CTS based multi-rate wireless local area networks. Based on the discovered rule, we propose two distributed fair auto rate medium access control schemes called FARM and FARM+ from the view-point of throughput fairness and time-share fairness, respectively. With the proposed schemes, after receiving a RTS frame, the receiver selectively returns the CTS frame to inform the transmitter the maximum feasible rate probed by the signal-to-noise ratio of the received RTS frame. The key feature of the proposed schemes is that they are capable of maintaining throughput/time-share fairness in asymmetric situation where the distribution of SNR varies with stations. Extensive simulation results show that the proposed schemes outperform the existing throughput/time-share fair auto rate schemes in time-varying channel conditions.
A Bridging Opportunities Work-frame to develop mobile applications for clinical decision making
van Rooij, Tibor; Rix, Serena; Moore, James B; Marsh, Sharon
2015-01-01
Background: Mobile applications (apps) providing clinical decision support (CDS) may show the greatest promise when created by and for frontline clinicians. Our aim was to create a generic model enabling healthcare providers to direct the development of CDS apps. Methods: We combined Change Management with a three-tier information technology architecture to stimulate CDS app development. Results: A Bridging Opportunities Work-frame model was developed. A test case was used to successfully develop an app. Conclusion: Healthcare providers can re-use this globally applicable model to actively create and manage regional decision support applications to translate evidence-based medicine in the use of emerging medication or novel treatment regimens. PMID:28031883
Persuasive Performance Feedback: The Effect of Framing on Self-Efficacy
Choe, Eun Kyoung; Lee, Bongshin; Munson, Sean; Pratt, Wanda; Kientz, Julie A.
2013-01-01
Self-monitoring technologies have proliferated in recent years as they offer excellent potential for promoting healthy behaviors. Although these technologies have varied ways of providing real-time feedback on a user’s current progress, we have a dearth of knowledge of the framing effects on the performance feedback these tools provide. With an aim to create influential, persuasive performance feedback that will nudge people toward healthy behaviors, we conducted an online experiment to investigate the effect of framing on an individual’s self-efficacy. We identified 3 different types of framing that can be applicable in presenting performance feedback: (1) the valence of performance (remaining vs. achieved framing), (2) presentation type (text-only vs. text with visual), and (3) data unit (raw vs. percentage). Results show that the achieved framing could lead to an increased perception of individual’s performance capabilities. This work provides empirical guidance for creating persuasive performance feedback, thereby helping people designing self-monitoring technologies to promote healthy behaviors. PMID:24551378
Persuasive performance feedback: the effect of framing on self-efficacy.
Choe, Eun Kyoung; Lee, Bongshin; Munson, Sean; Pratt, Wanda; Kientz, Julie A
2013-01-01
Self-monitoring technologies have proliferated in recent years as they offer excellent potential for promoting healthy behaviors. Although these technologies have varied ways of providing real-time feedback on a user's current progress, we have a dearth of knowledge of the framing effects on the performance feedback these tools provide. With an aim to create influential, persuasive performance feedback that will nudge people toward healthy behaviors, we conducted an online experiment to investigate the effect of framing on an individual's self-efficacy. We identified 3 different types of framing that can be applicable in presenting performance feedback: (1) the valence of performance (remaining vs. achieved framing), (2) presentation type (text-only vs. text with visual), and (3) data unit (raw vs. percentage). Results show that the achieved framing could lead to an increased perception of individual's performance capabilities. This work provides empirical guidance for creating persuasive performance feedback, thereby helping people designing self-monitoring technologies to promote healthy behaviors.
ML Frame Synchronization for OFDM Systems Using a Known Pilot and Cyclic Prefixes
NASA Astrophysics Data System (ADS)
Huh, Heon
Orthogonal frequency-division multiplexing (OFDM) is a popular air interface technology that is adopted as a standard modulation scheme for 4G communication systems owing to its excellent spectral efficiency. For OFDM systems, synchronization problems have received much attention along with peak-to-average power ratio (PAPR) reduction. In addition to frequency offset estimation, frame synchronization is a challenging problem that must be solved to achieve optimal system performance. In this paper, we present a maximum likelihood (ML) frame synchronizer for OFDM systems. The synchronizer exploits a synchronization word and cyclic prefixes together to improve the synchronization performance. Numerical results show that the performance of the proposed frame synchronizer is better than that of conventional schemes. The proposed synchronizer can be used as a reference for evaluating the performance of other suboptimal frame synchronizers. We also modify the proposed frame synchronizer to reduce the implementation complexity and propose a near-ML synchronizer for time-varying fading channels.
Abood, Doris A; Coster, Daniel C; Mullis, Ann K; Black, David R
2002-01-01
This study was conducted because mammography is under-utilized, even though it is the most effective early detection screening device for breast cancer. A loss-framed telephonic message based on prospect theory was evaluated for the effects on mammography utilization among medically un- and under-insured women living in demographically similar rural counties in Florida. The sample consisted mostly of White women (approximately 89%) 50-64 years old. Experimental group participants received the loss-framed message telephonically and those in the comparison group received the "usual telephone procedure." Logistic regression analyses revealed that women who received the loss-framed message were six times more likely to obtain a mammogram (OR = 6.6, P < 0.0001). The impact of the loss-framed message persisted even after adjustment for initial versus re-screen mammogram effects. This in-reach, loss-framed, minimal intervention seems to have viability and may serve as an alternative or adjunct program for encouraging women to receive mammograms.
[A development of FRP frame for crown and bridge resin. (2) Rigidity and adaptability of FRP frame].
Kimura, H; Teraoka, F
1990-05-01
Retainer and pontic of FRP frame for crown and bridge resin were constructed with two different prepregs, used glass cloth and roving as reinforcement. Rigidity and adaptability of the FRP frame and bonding strength of jointing of retainer and pontic were investigated. The glass content was about 50 wt% for both kinds of prepregs. Bonding strength and modulus of FRP plate reinforced with glass roving were about 1.5 times larger than that of the FRP plate reinforced with glass cloth. Bonding strength of FRP specimen constructed by curing the prepreg put on the FRP plate was about 3 kgf/mm2. However, the bonding strength of specimen constructed by curing simultaneously the two prepregs was about 12 kgf/mm2. Though discrepancy of the FRP frame to stone cast of abutment tooth was proportional to the length of pontic, that of the FRP frame with a 50 mm pontic was less than 0.05 mm.
Seismic response of reinforced concrete frames at different damage levels
NASA Astrophysics Data System (ADS)
Morales-González, Merangeli; Vidot-Vega, Aidcer L.
2017-03-01
Performance-based seismic engineering is focused on the definition of limit states to represent different levels of damage, which can be described by material strains, drifts, displacements or even changes in dissipating properties and stiffness of the structure. This study presents a research plan to evaluate the behavior of reinforced concrete (RC) moment resistant frames at different performance levels established by the ASCE 41-06 seismic rehabilitation code. Sixteen RC plane moment frames with different span-to-depth ratios and three 3D RC frames were analyzed to evaluate their seismic behavior at different damage levels established by the ASCE 41-06. For each span-to-depth ratio, four different beam longitudinal reinforcement steel ratios were used that varied from 0.85 to 2.5% for the 2D frames. Nonlinear time history analyses of the frames were performed using scaled ground motions. The impact of different span-to-depth and reinforcement ratios on the damage levels was evaluated. Material strains, rotations and seismic hysteretic energy changes at different damage levels were studied.
Physics of Non-Inertial Reference Frames
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kamalov, Timur F.
2010-12-22
Physics of non-inertial reference frames is a generalizing of Newton's laws to any reference frames. It is the system of general axioms for classical and quantum mechanics. The first, Kinematics Principle reads: the kinematic state of a body free of forces conserves and equal in absolute value to an invariant of the observer's reference frame. The second, Dynamics Principle extended Newton's second law to non-inertial reference frames and also contains additional variables there are higher derivatives of coordinates. Dynamics Principle reads: a force induces a change in the kinematic state of the body and is proportional to the rate ofmore » its change. It is mean that if the kinematic invariant of the reference frame is n-th derivative with respect the time, then the dynamics of a body being affected by the force F is described by the 2n-th differential equation. The third, Statics Principle reads: the sum of all forces acting a body at rest is equal to zero.« less
SU-E-T-68: A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueda, Y; Hirose, A; Oohira, S
Purpose: The purpose of this work was to develop a quality assurance (QA) system for high dose rate (HDR) brachytherapy to verify the absolute position of an 192Ir source in real time and to measure dwell time and position of the source simultaneously with a movie recorded by a web camera. Methods: A web camera was fixed 15 cm above a source position check ruler to monitor and record 30 samples of the source position per second over a range of 8.0 cm, from 1425 mm to 1505 mm. Each frame had a matrix size of 480×640 in the movie.more » The source position was automatically quantified from the movie using in-house software (built with LabVIEW) that applied a template-matching technique. The source edge detected by the software on each frame was corrected to reduce position errors induced by incident light from an oblique direction. The dwell time was calculated by differential processing to displacement of the source. The performance of this QA system was illustrated by recording simple plans and comparing the measured dwell positions and time with the planned parameters. Results: This QA system allowed verification of the absolute position of the source in real time. The mean difference between automatic and manual detection of the source edge was 0.04 ± 0.04 mm. Absolute position error can be determined within an accuracy of 1.0 mm at dwell points of 1430, 1440, 1450, 1460, 1470, 1480, 1490, and 1500 mm, in three step sizes and dwell time errors, with an accuracy of 0.1% in more than 10.0 sec of planned time. The mean step size error was 0.1 ± 0.1 mm for a step size of 10.0 mm. Conclusion: This QA system provides quick verifications of the dwell position and time, with high accuracy, for HDR brachytherapy. This work was supported by the Japan Society for the Promotion of Science Core-to-Core program (No. 23003)« less
Saunders, Carla; Carter, David J
2017-10-01
Objective The overall aim of the study was to investigate and assess the feasibility of improving the timeliness of public hospital care through a New South Wales (NSW)-wide public-private hospital partnership. Methods The study reviewed the academic and professional grey literature, and undertook exploratory analyses of secondary data acquired from two national health data repositories informing in-patient access and utilisation across NSW public and private hospitals. Results In 2014-15, the NSW public hospital system was unable to deliver care within the medically recommended time frame for over 27400 people who were awaiting elective surgery. Available information indicates that the annual commissioning of 15% of public in-patient rehabilitation bed days to the private hospital system would potentially free up enough capacity in the NSW public hospital system to enable elective surgery for all public patients within recommended time frames. Conclusions The findings of the study justify a strategic whole-of-health system approach to reducing public patient wait times in NSW and highlight the need for research efforts aimed at securing a better understanding of available hospital capacity across the public and private hospital systems, and identifying and testing workable models that improve the timeliness of public hospital care. What is known about the topic? There are very few studies available to inform public-private hospital service partnerships and the opportunities available to improve timely health care access through such partnerships. What does this paper add? This paper has the potential to open and prompt timely discussion and debate, and generate further fundamental investigation, on public-private hospital service partnerships in Australia where opportunity is available to address elective surgery wait times in a reliable and effective manner. What are the implications for practitioners? The NSW Ministry of Health and its Local Health Districts have the potential to realise a key objective, namely to deliver the 'right care, in the right place, at the right time', through the core value of collaboration, using available infrastructure.
On the sensitivity analysis of porous material models
NASA Astrophysics Data System (ADS)
Ouisse, Morvan; Ichchou, Mohamed; Chedly, Slaheddine; Collet, Manuel
2012-11-01
Porous materials are used in many vibroacoustic applications. Different available models describe their behaviors according to materials' intrinsic characteristics. For instance, in the case of porous material with rigid frame, and according to the Champoux-Allard model, five parameters are employed. In this paper, an investigation about this model sensitivity to parameters according to frequency is conducted. Sobol and FAST algorithms are used for sensitivity analysis. A strong parametric frequency dependent hierarchy is shown. Sensitivity investigations confirm that resistivity is the most influent parameter when acoustic absorption and surface impedance of porous materials with rigid frame are considered. The analysis is first performed on a wide category of porous materials, and then restricted to a polyurethane foam analysis in order to illustrate the impact of the reduction of the design space. In a second part, a sensitivity analysis is performed using the Biot-Allard model with nine parameters including mechanical effects of the frame and conclusions are drawn through numerical simulations.
Gerend, Mary A.; Shepherd, Janet E.
2012-01-01
Background Although theories of health behavior have guided thousands of studies, relatively few studies have compared these theories against one another. Purpose The purpose of the current study was to compare two classic theories of health behavior—the Health Belief Model (HBM) and the Theory of Planned Behavior (TPB)—in their prediction of human papillomavirus (HPV) vaccination. Methods After watching a gain-framed, loss-framed, or control video, women (N=739) ages 18–26 completed a survey assessing HBM and TPB constructs. HPV vaccine uptake was assessed ten months later. Results Although the message framing intervention had no effect on vaccine uptake, support was observed for both the TPB and HBM. Nevertheless, the TPB consistently outperformed the HBM. Key predictors of uptake included subjective norms, self-efficacy, and vaccine cost. Conclusions Despite the observed advantage of the TPB, findings revealed considerable overlap between the two theories and highlighted the importance of proximal versus distal predictors of health behavior. PMID:22547155
Geiger-mode APD camera system for single-photon 3D LADAR imaging
NASA Astrophysics Data System (ADS)
Entwistle, Mark; Itzler, Mark A.; Chen, Jim; Owens, Mark; Patel, Ketan; Jiang, Xudong; Slomkowski, Krystyna; Rangwala, Sabbir
2012-06-01
The unparalleled sensitivity of 3D LADAR imaging sensors based on single photon detection provides substantial benefits for imaging at long stand-off distances and minimizing laser pulse energy requirements. To obtain 3D LADAR images with single photon sensitivity, we have demonstrated focal plane arrays (FPAs) based on InGaAsP Geiger-mode avalanche photodiodes (GmAPDs) optimized for use at either 1.06 μm or 1.55 μm. These state-of-the-art FPAs exhibit excellent pixel-level performance and the capability for 100% pixel yield on a 32 x 32 format. To realize the full potential of these FPAs, we have recently developed an integrated camera system providing turnkey operation based on FPGA control. This system implementation enables the extremely high frame-rate capability of the GmAPD FPA, and frame rates in excess of 250 kHz (for 0.4 μs range gates) can be accommodated using an industry-standard CameraLink interface in full configuration. Real-time data streaming for continuous acquisition of 2 μs range gate point cloud data with 13-bit time-stamp resolution at 186 kHz frame rates has been established using multiple solid-state storage drives. Range gate durations spanning 4 ns to 10 μs provide broad operational flexibility. The camera also provides real-time signal processing in the form of multi-frame gray-scale contrast images and single-frame time-stamp histograms, and automated bias control has been implemented to maintain a constant photon detection efficiency in the presence of ambient temperature changes. A comprehensive graphical user interface has been developed to provide complete camera control using a simple serial command set, and this command set supports highly flexible end-user customization.
Analysis of usage and associated cost of external fixators at an urban level 1 trauma centre.
Chaus, George W; Dukes, Chase; Hak, David J; Mauffrey, Cyril; Mark Hammerberg, E
2014-10-01
To determine the usage, indication, duration, and cost associated with external fixation usage. Additionally, to show the significant cost associated with external fixator use and reinvigorate discussions on external fixator reuse. A retrospective review of a prospectively gathered trauma database was undertaken to identify all patients treated with external fixation frames for pelvic and lower extremity injuries between September 2007 and July 2010. We noted the indications for frame use, and we determined the average duration of external fixation for each indication. The cost of each frame was calculated from implant records. 341 lower extremity and pelvic fractures were treated with external fixation frames during the study period. Of these, 92% were used as temporary external fixation. The average duration of temporary external fixation was 10.5 days. The cost of external fixation frame components was $670,805 per year. The average cost per external fixation frame was $5900. The majority of external fixators are intended as temporary frames, in place for a limited period of time prior to definitive fixation of skeletal injuries. As such, most frames are not intended to withstand physiologic loads, nor are they expected provide a precise maintenance of reduction. Given the considerable expense associated with external fixation frame components, the practice of purchasing external fixation frame components as disposable "single-use" items appears to be somewhat wasteful. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.
Jin, Jia; Zhang, Wuke; Chen, Mingliang
2017-12-01
Due to the limitations of the human ability to process information, e-consumers' decisions are likely to be influenced by various cognitive biases, such as the attribute framing effect. This effect has been well studied by numerous scholars; however, the associated underlying neural mechanisms with a critical temporal resolution have not been revealed. Thus, this study applies the measurement of event-related potentials (ERPs) to directly examine the role of attribute framing in information processing and decision-making in online shopping. The behavioral results showed that participants demonstrated a higher purchase intention with a shorter reaction time under a positive framing condition compared to participants under a negative framing condition. Compared with positive framing messages, the results of ERPs indicated that negative framing messages attracted more attention resources at the early stage of rapid automatic processing (larger P2 amplitude) and resulted in greater cognitive conflict and decision difficulty (larger P2-N2 complex). Moreover, compared with negative messages, positive framing messages allowed consumers to perceive a better future performance of products and classify these products as a categorization of higher evaluation (larger LPP amplitude) at the late cognitive processing stage of evaluation. Based on these results, we provide evidence for a better understanding of how different attribute framing messages are processed and ultimately lead to the framing effect. Copyright © 2017 Elsevier Ireland Ltd and Japan Neuroscience Society. All rights reserved.
``Frames of Reference'' revisited
NASA Astrophysics Data System (ADS)
Steyn-Ross, Alistair; Ivey, Donald G.
1992-12-01
The PSSC teaching film, ``Frames of Reference,'' was made in 1960, and was one of the first audio-visual attempts at showing how your physical ``point of view,'' or frame of reference, necessarily alters both your perceptions and your observations of motion. The gentle humor and original demonstrations made a lasting impact on many audiences, and with its recent re-release as part of the AAPT Cinema Classics videodisc it is timely that we should review both the message and the methods of the film. An annotated script and photographs from the film are presented, followed by extension material on rotating frames which teachers may find appropriate for use in their classrooms: constructions, demonstrations, an example, and theory.
High frame-rate en face optical coherence tomography system using KTN optical beam deflector
NASA Astrophysics Data System (ADS)
Ohmi, Masato; Shinya, Yusuke; Imai, Tadayuki; Toyoda, Seiji; Kobayashi, Junya; Sakamoto, Tadashi
2017-02-01
We developed high frame-rate en face optical coherence tomography (OCT) system using KTa1-xNbxO3 (KTN) optical beam deflector. In the imaging system, the fast scanning was performed at 200 kHz by the KTN optical beam deflector, while the slow scanning was performed at 800 Hz by the galvanometer mirror. As a preliminary experiment, we succeeded in obtaining en face OCT images of human fingerprint with a frame rate of 800 fps. This is the highest frame-rate obtained using time-domain (TD) en face OCT imaging. The 3D-OCT image of sweat gland was also obtained by our imaging system.
Construction Theory and Noise Analysis Method of Global CGCS2000 Coordinate Frame
NASA Astrophysics Data System (ADS)
Jiang, Z.; Wang, F.; Bai, J.; Li, Z.
2018-04-01
The definition, renewal and maintenance of geodetic datum has been international hot issue. In recent years, many countries have been studying and implementing modernization and renewal of local geodetic reference coordinate frame. Based on the precise result of continuous observation for recent 15 years from state CORS (continuously operating reference system) network and the mainland GNSS (Global Navigation Satellite System) network between 1999 and 2007, this paper studies the construction of mathematical model of the Global CGCS2000 frame, mainly analyzes the theory and algorithm of two-step method for Global CGCS2000 Coordinate Frame formulation. Finally, the noise characteristic of the coordinate time series are estimated quantitatively with the criterion of maximum likelihood estimation.
Media framing of complex issues: The case of endangered languages.
Rivenburgh, Nancy K
2013-08-01
This study investigates how media frame a global trend that is complex in nature, emergent in terms of scientific understanding, and has public policy implications: the rapid disappearance of languages. It analyzes how English-language media from 15 western, industrialized countries frame the causes and implications of endangered languages over 35 years (1971-2006) - a time period notable for growing, interdisciplinary concerns over the potential negative impacts of losing the world's linguistic diversity. The results reveal a media discourse characterized by three complementary frames that are sympathetic to the plight of endangered languages, but that present the problem, its cause, and societal implications in a logical structure that would promote public complacency.
Altered risk-aversion and risk-taking behaviour in patients with Alzheimer's disease.
Ha, Juwon; Kim, Eun-Jin; Lim, Sewon; Shin, Dong-Won; Kang, Yeo-Jin; Bae, Seung-Min; Yoon, Hyung-Kun; Oh, Kang-Seob
2012-09-01
Normal individuals are risk averse for decisions framed as gains but risk taking for decisions framed as losses. This framing effect is supposed to be attenuated in Alzheimer's disease (AD) patients. We investigated the effects of highlighting rewards versus highlighting punishments on the risky decision-making of AD patients. Fourteen mild to moderate AD patients (Mini-Mental Status Examination score, 11-23; Clinical Dementia Rating, 1-2) and 16 healthy volunteers were recruited for the study. Subjects completed a computerized task on risky decision-making in which mathematically equivalent dilemmas were presented in terms of opportunities to gain monetary rewards ('positive frame') or avoid suffering losses ('negative frame'). As expected, AD patients chose more risky options under the positive frame than the negative frame, contrary to the control group (Z =-2.671, P= 0.007). The normal difference in the distribution of risky choices between positively and negatively framed dilemmas was significantly reduced in the AD group after we adjusted for years of education, mean age and depression (F= 5.321, P= 0.030). Deliberation time did not differ significantly between the two groups. These results suggest that AD patients making high-risk choices is associated with attenuated sensitivity to the emotional frames that highlight rewards or punishments, possibly reflecting altered evaluations of prospective gains and losses. © 2012 The Authors. Psychogeriatrics © 2012 Japanese Psychogeriatric Society.
Qin, Youxiang; Zhang, Junjie
2017-07-10
A novel low complexity and energy-efficient scheme by controlling the toggle-rate of ONU with time-domain amplitude identification is proposed for a heavy load downlink in an intensity-modulation and direct-detection orthogonal frequency division multiplexing passive optical network (IM-DD OFDM-PON). In a conventional OFDM-PON downlink, all ONUs have to perform demodulation for all the OFDM frames in a broadcast way no matter whether the frames are targeted to or not, which causes a huge energy waste. However, in our scheme, the optical network unit (ONU) logical link identifications (LLIDs) are inserted into each downlink OFDM frame in time-domain at the optical line terminal (OLT) side. At the ONU side, the LLID is obtained with a low complexity and high precision amplitude identification method. The ONU sets the toggle-rate of demodulation module to zero when the frames are not targeted to, which avoids unnecessary digital signal processing (DSP) energy consumption. Compared with the sleep-mode methods consisting of clock recovery and synchronization, toggle-rate shows its advantage in fast changing, which is more suitable for the heavy load scenarios. Moreover, for the first time to our knowledge, the characteristics of the proposed scheme are investigated in a real-time IM-DD OFDM system, which performs well at the received optical power as low as -21dBm. The experimental results show that 25.1% energy consumption can be saved in the receiver compared to the conventional configurations.
Space-based solar power conversion and delivery systems (study), engineering analysis
NASA Technical Reports Server (NTRS)
Nathan, C. A.
1975-01-01
A systems analysis of synchronous, orbit-based power generation and relay systems that could be operational in the 1990's is described along with a comparison with earth-based systems to be operational in the same time frame. Operational and economic requirements for the orbiting systems and near term research activities which will be required to assure feasibility, development, launch and operational capabilities of such systems in the post- 1990 time frame are examined.
MobileFusion: real-time volumetric surface reconstruction and dense tracking on mobile phones.
Ondrúška, Peter; Kohli, Pushmeet; Izadi, Shahram
2015-11-01
We present the first pipeline for real-time volumetric surface reconstruction and dense 6DoF camera tracking running purely on standard, off-the-shelf mobile phones. Using only the embedded RGB camera, our system allows users to scan objects of varying shape, size, and appearance in seconds, with real-time feedback during the capture process. Unlike existing state of the art methods, which produce only point-based 3D models on the phone, or require cloud-based processing, our hybrid GPU/CPU pipeline is unique in that it creates a connected 3D surface model directly on the device at 25Hz. In each frame, we perform dense 6DoF tracking, which continuously registers the RGB input to the incrementally built 3D model, minimizing a noise aware photoconsistency error metric. This is followed by efficient key-frame selection, and dense per-frame stereo matching. These depth maps are fused volumetrically using a method akin to KinectFusion, producing compelling surface models. For each frame, the implicit surface is extracted for live user feedback and pose estimation. We demonstrate scans of a variety of objects, and compare to a Kinect-based baseline, showing on average ∼ 1.5cm error. We qualitatively compare to a state of the art point-based mobile phone method, demonstrating an order of magnitude faster scanning times, and fully connected surface models.
VLBI-based Products - Naval Oceanography Portal
section Advanced Search... Sections Home Time Earth Orientation Astronomy Meteorology Oceanography Ice You terrestrial reference frames and to predict the variable orientation of the Earth in three-dimensional space antennas that define a VLBI-based Terrestrial Reference Frame (TRF) and the Earth Orientation Parameters
Single-Frame Cinema. Three Dimensional Computer-Generated Imaging.
ERIC Educational Resources Information Center
Cheetham, Edward Joseph, II
This master's thesis provides a description of the proposed art form called single-frame cinema, which is a category of computer imagery that takes the temporal polarities of photography and cinema and unites them into a single visual vignette of time. Following introductory comments, individual chapters discuss (1) the essential physical…
NASA Technical Reports Server (NTRS)
Watson, Andrew B.
2012-01-01
To enhance the quality of the theatre experience, the film industry is interested in achieving higher frame rates for capture and display. In this talk I will describe the basic spatio-temporal sensitivities of human vision, and how they respond to the time sequence of static images that is fundamental to cinematic presentation.
High-Frame-Rate Doppler Ultrasound Using a Repeated Transmit Sequence
Podkowa, Anthony S.; Oelze, Michael L.; Ketterling, Jeffrey A.
2018-01-01
The maximum detectable velocity of high-frame-rate color flow Doppler ultrasound is limited by the imaging frame rate when using coherent compounding techniques. Traditionally, high quality ultrasonic images are produced at a high frame rate via coherent compounding of steered plane wave reconstructions. However, this compounding operation results in an effective downsampling of the slow-time signal, thereby artificially reducing the frame rate. To alleviate this effect, a new transmit sequence is introduced where each transmit angle is repeated in succession. This transmit sequence allows for direct comparison between low resolution, pre-compounded frames at a short time interval in ways that are resistent to sidelobe motion. Use of this transmit sequence increases the maximum detectable velocity by a scale factor of the transmit sequence length. The performance of this new transmit sequence was evaluated using a rotating cylindrical phantom and compared with traditional methods using a 15-MHz linear array transducer. Axial velocity estimates were recorded for a range of ±300 mm/s and compared to the known ground truth. Using these new techniques, the root mean square error was reduced from over 400 mm/s to below 50 mm/s in the high-velocity regime compared to traditional techniques. The standard deviation of the velocity estimate in the same velocity range was reduced from 250 mm/s to 30 mm/s. This result demonstrates the viability of the repeated transmit sequence methods in detecting and quantifying high-velocity flow. PMID:29910966
Description and User Instructions for the Quaternion_to_Orbit_v3 Software
NASA Technical Reports Server (NTRS)
Strekalov, Dmitry V.; Kruizinga, Gerhard L.; Paik, Meegyeong; Yuan, Dah-Ning; Asmar, Sami W.
2012-01-01
For a given inertial frame of reference, the software combines the spacecraft orbits with the spacecraft attitude quaternions, and rotates the body-fixed reference frame of a particular spacecraft to the inertial reference frame. The conversion assumes that the two spacecraft are aligned with respect to the mutual line of sight, with a parameterized time tag. The software is implemented in Python and is completely open source. It is very versatile, and may be applied under various circumstances and for other related purposes. Based on the solid linear algebra analysis, it has an extra option for compensating the linear pitch. This software has been designed for simulation of the calibration maneuvers performed by the two spacecraft comprising the GRAIL mission to the Moon, but has potential use for other applications. In simulations of formation flights, one needs to coordinate the spacecraft orbits represented in an appropriate inertial reference frame and the spacecraft attitudes. The latter are usually given as the time series of quaternions rotating the body-fixed reference frame of a particular spacecraft to the inertial reference frame. It is often desirable to simulate the same maneuver for different segments of the orbit. It is also useful to study various maneuvers that could be performed at the same orbit segment. These two lines of study are more timeand labor-efficient if the attitude and orbit data are generated independently, so that the part of the data that has not been changed can be recycled in the course of multiple simulations.
NASA Astrophysics Data System (ADS)
Zhu, Ning; Sun, Shouguang; Li, Qiang; Zou, Hua
2016-05-01
When a train runs at high speeds, the external exciting frequencies approach the natural frequencies of bogie critical components, thereby inducing strong elastic vibrations. The present international reliability test evaluation standard and design criteria of bogie frames are all based on the quasi-static deformation hypothesis. Structural fatigue damage generated by structural elastic vibrations has not yet been included. In this paper, theoretical research and experimental validation are done on elastic dynamic load spectra on bogie frame of high-speed train. The construction of the load series that correspond to elastic dynamic deformation modes is studied. The simplified form of the load series is obtained. A theory of simplified dynamic load-time histories is then deduced. Measured data from the Beijing-Shanghai Dedicated Passenger Line are introduced to derive the simplified dynamic load-time histories. The simplified dynamic discrete load spectra of bogie frame are established. Based on the damage consistency criterion and a genetic algorithm, damage consistency calibration of the simplified dynamic load spectra is finally performed. The computed result proves that the simplified load series is reasonable. The calibrated damage that corresponds to the elastic dynamic discrete load spectra can cover the actual damage at the operating conditions. The calibrated damage satisfies the safety requirement of damage consistency criterion for bogie frame. This research is helpful for investigating the standardized load spectra of bogie frame of high-speed train.
Kondyurin, A; Lauke, B; Kondyurina, I; Orba, E
2004-01-01
The large-size frame of space ship and space station can be created with the use of the technology of the polymerization of fiber-filled composites and a liquid reactionable matrix applied in free space or on the other space body when the space ship or space station will be used during a long period of time. For the polymerization of the station frame the fabric impregnated with a long-life polymer matrix (prepreg) is prepared in terrestrial conditions and, after folding, can be shipped in a compact container to orbit and kept folded on board the station. In due time the prepreg is carried out into free space and unfolded. Then a reaction of matrix polymerization starts. After reaction of polymerization the durable frame is ready for exploitation. After that, the frame can be filled out with air, the apparatus and life support systems. The technology can be used for creation of biological frame as element of self regulating ecological system, and for creation of technological frame which can be used for a production of new materials on Earth orbit in microgravity conditions and on other space bodies (Mars, Moon, asteroids) for unique high price mineral extraction. Based on such technology a future space base on Earth orbit with volume of 10(6) m3 and a crew of 100 astronauts is considered. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
Temporal framing and the hidden-zero effect: rate-dependent outcomes on delay discounting.
Naudé, Gideon P; Kaplan, Brent A; Reed, Derek D; Henley, Amy J; DiGennaro Reed, Florence D
2018-05-01
Recent research suggests that presenting time intervals as units (e.g., days) or as specific dates, can modulate the degree to which humans discount delayed outcomes. Another framing effect involves explicitly stating that choosing a smaller-sooner reward is mutually exclusive to receiving a larger-later reward, thus presenting choices as an extended sequence. In Experiment 1, participants (N = 201) recruited from Amazon Mechanical Turk completed the Monetary Choice Questionnaire in a 2 (delay framing) by 2 (zero framing) design. Regression suggested a main effect of delay, but not zero, framing after accounting for other demographic variables and manipulations. We observed a rate-dependent effect for the date-framing group, such that those with initially steep discounting exhibited greater sensitivity to the manipulation than those with initially shallow discounting. Subsequent analyses suggest these effects cannot be explained by regression to the mean. Experiment 2 addressed the possibility that the null effect of zero framing was due to within-subject exposure to the hidden- and explicit-zero conditions. A new Amazon Mechanical Turk sample completed the Monetary Choice Questionnaire in either hidden- or explicit-zero formats. Analyses revealed a main effect of reward magnitude, but not zero framing, suggesting potential limitations to the generality of the hidden-zero effect. © 2018 Society for the Experimental Analysis of Behavior.
Newton-Cartan Gravity in Noninertial Reference Frames
NASA Astrophysics Data System (ADS)
Rodriguez, Leo; St. Germaine-Fuller, James; Wickramasekara, Sujeev
2015-03-01
We study Newton-Cartan gravity under transformations into all noninertial, nonrelativistic reference frames. These transformations form an infinite dimensional Lie group, called the Galilean line group, which contains as a subgroup the Galilei group. The fictitious forces of noninertial reference frames are encoded in the Cartan connection transformed under the Galilean line group. These fictitious forces, which are coordinate effects, do not contribute to the Ricci tensor. Only the 00-component of the Ricci tensor is non-zero and equals (4 π times) the matter density in all reference frames. While the Ricci field equation and Gauss' law are fulfilled by the physical matter density in inertial and linearly accelerating reference frames, in rotating reference frames Gauss' law holds for an effective mass density that differs from the physical matter density. This effective density has its origin in the simulated magnetic field of rotating frames, highlighting a striking difference between linearly and rotationally accelerating frames. The equations governing the simulated fields have the same form as Maxwell's equations, a surprising result given that these equations obey special relativity (and U (1) -gauge symmetry), rather than Galilean symmetry. This work was supported in part by the HHMI Undergraduate Science Education Award 52006298 and the Grinnell College Academic Affairs' CSFS and MAP programs.
Let's drink and be merry: the framing of alcohol in the prime-time American youth series The OC.
Van Den Bulck, Hilde; Simons, Nele; Gorp, Baldwin Van
2008-11-01
This study analyzed the framing of alcohol consumption in the American adolescent drama series The OC. All 51 episodes of Seasons 1 and 2 of The OC were coded for visual and verbal references to beverage use on the level of the scene (n = 1,895) and on the level of the drinking act (n = 1,033). Subsequently, all episodes were analyzed qualitatively through an inductive frame analysis. Although the public's perception of The OC is that alcohol was overrepresented in this series, the quantitative results show the opposite. The focus was on active consumption and solitary drinking of alcohol, but in absolute terms there were more nonalcoholic drinking acts. The OC represents a trend break, compared with earlier analyses of alcohol consumption in television fiction: More than half of all alcoholic drinking acts involved women, and almost one third involved adolescents. The qualitative frame analysis revealed two commonly used frames (alcohol consumption as an "obligatory outlet" and alcohol consumption as "escapism") and two less frequently applied frames ("celebrate without the sauce" and alcohol addiction as "sickness"). The findings suggest that the concept of framing might contribute to this field of study by analyzing the underlying cultural frames that suggest how the receiver may interpret the consumption of alcohol in fictional television programs.
The Global Health Policies of the EU and its Member States: A Common Vision?
Steurs, Lies; Van de Pas, Remco; Delputte, Sarah; Orbie, Jan
2018-01-01
Background: This article assesses the global health policies of the European Union (EU) and those of its individual member states. So far EU and public health scholars have paid little heed to this, despite the large budgets involved in this area. While the European Commission has attempted to define the ‘EU role in Global Health’ in 2010, member states are active in the domain of global health as well. Therefore, this article raises the question to what extent a common ‘EU’ vision on global health exists. Methods: This is examined through a comparative framing analysis of the global health policy documents of the European Commission and five EU member states (France, Germany, the United Kingdom, Belgium, and Denmark). The analysis is informed by a two-layered typology, distinguishing global health from international health and four ‘global health frames,’ namely social justice, security, investment and charity. Results: The findings show that the concept of ‘global health’ has not gained ground the same way within European policy documents. Consequently, there are also differences in how health is being framed. While the European Commission, Belgium, and Denmark clearly support a social justice frame, the global health strategies of the United Kingdom, Germany, and France put an additional focus on the security and investment frames. Conclusion: There are different understandings of global/international health as well as different framings within relevant documents of the EU and its member states. Therefore, the existence of an ‘EU’ vision on global health is questionable. Further research is needed on how this impacts on policy implementation. PMID:29764107
Algorithm for Video Summarization of Bronchoscopy Procedures
2011-01-01
Background The duration of bronchoscopy examinations varies considerably depending on the diagnostic and therapeutic procedures used. It can last more than 20 minutes if a complex diagnostic work-up is included. With wide access to videobronchoscopy, the whole procedure can be recorded as a video sequence. Common practice relies on an active attitude of the bronchoscopist who initiates the recording process and usually chooses to archive only selected views and sequences. However, it may be important to record the full bronchoscopy procedure as documentation when liability issues are at stake. Furthermore, an automatic recording of the whole procedure enables the bronchoscopist to focus solely on the performed procedures. Video recordings registered during bronchoscopies include a considerable number of frames of poor quality due to blurry or unfocused images. It seems that such frames are unavoidable due to the relatively tight endobronchial space, rapid movements of the respiratory tract due to breathing or coughing, and secretions which occur commonly in the bronchi, especially in patients suffering from pulmonary disorders. Methods The use of recorded bronchoscopy video sequences for diagnostic, reference and educational purposes could be considerably extended with efficient, flexible summarization algorithms. Thus, the authors developed a prototype system to create shortcuts (called summaries or abstracts) of bronchoscopy video recordings. Such a system, based on models described in previously published papers, employs image analysis methods to exclude frames or sequences of limited diagnostic or education value. Results The algorithm for the selection or exclusion of specific frames or shots from video sequences recorded during bronchoscopy procedures is based on several criteria, including automatic detection of "non-informative", frames showing the branching of the airways and frames including pathological lesions. Conclusions The paper focuses on the challenge of generating summaries of bronchoscopy video recordings. PMID:22185344
Lung tumor tracking in fluoroscopic video based on optical flow
Xu, Qianyi; Hamilton, Russell J.; Schowengerdt, Robert A.; Alexander, Brian; Jiang, Steve B.
2008-01-01
Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels (∼0.7 mm) in the best case and 2.8 pixels (∼1.4 mm) in the worst case for the five patients studied. PMID:19175094
Lung tumor tracking in fluoroscopic video based on optical flow.
Xu, Qianyi; Hamilton, Russell J; Schowengerdt, Robert A; Alexander, Brian; Jiang, Steve B
2008-12-01
Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels (approximately 0.7 mm) in the best case and 2.8 pixels (approximately 1.4 mm) in the worst case for the five patients studied.
Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J
2010-10-01
High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.
Labadie, Robert F; Balachandran, Ramya; Noble, Jack H; Blachon, Grégoire S; Mitchell, Jason E; Reda, Fitsum A; Dawant, Benoit M; Fitzpatrick, J Michael
2015-01-01
OBJECTIVE Minimally-invasive image-guided approach to cochlear implantation (CI) involves drilling a narrow, linear tunnel to the cochlea. Reported herein is the first clinical implementation of this approach. STUDY DESIGN Prospective, cohort study. METHODS On preoperative CT, a safe linear trajectory through the facial recess targeting the scala tympani was planned. Intraoperatively, fiducial markers were bone-implanted, a second CT was acquired, and the trajectory was transferred from preoperative to intraoperative CT. A customized microstereotactic frame was rapidly designed and constructed to constrain a surgical drill along the desired trajectory. Following sterilization, the frame was employed to drill the tunnel to the middle ear. After lifting a tympanomeatal flap and performing a cochleostomy, the electrode array was threaded through the drilled tunnel and into the cochlea. RESULTS Eight of nine patients were successfully implanted using the proposed approach with six insertions completely within scala tympani. Traditional mastoidectomy was performed on one patient following difficulty threading the electrode array via the narrow tunnel. Other difficulties encountered included use of the back-up implant when an electrode was dislodged during threading via the tunnel, tip fold-over, and facial nerve paresis (House-Brackmann II/VII at 12 months) secondary to heat during drilling. Average time of intervention was 182±36 minutes. CONCLUSION Minimally-invasive, image-guided CI is clinically achievable. Further clinical study is necessary to address technological difficulties during drilling and insertion and to assess potential benefits including decreased time of intervention, standardization of surgical intervention, and decreased tissue dissection potentially leading to shorter recovery and earlier implant activation. PMID:24272427