NASA Technical Reports Server (NTRS)
Leskovar, B.; Turko, B.
1977-01-01
The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.
High resolution data acquisition
Thornton, G.W.; Fuller, K.R.
1993-04-06
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
High resolution data acquisition
Thornton, Glenn W.; Fuller, Kenneth R.
1993-01-01
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
Versatile all-digital time interval measuring system
NASA Astrophysics Data System (ADS)
Vyhlidal, David; Cech, Miroslav
2011-06-01
This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.
NASA Astrophysics Data System (ADS)
Szplet, R.; Kalisz, J.; Jachna, Z.
2009-02-01
We present a time digitizer having 45 ps resolution, integrated in a field programmable gate array (FPGA) device. The time interval measurement is based on the two-stage interpolation method. A dual-edge two-phase interpolator is driven by the on-chip synthesized 250 MHz clock with precise phase adjustment. An improved dual-edge double synchronizer was developed to control the main counter. The nonlinearity of the digitizer's transfer characteristic is identified and utilized by the dedicated hardware code processor for the on-the-fly correction of the output data. Application of presented ideas has resulted in the measurement uncertainty of the digitizer below 70 ps RMS over the time interval ranging from 0 to 1 s. The use of the two-stage interpolation and a fast FIFO memory has allowed us to obtain the maximum measurement rate of five million measurements per second.
Modulation Based on Probability Density Functions
NASA Technical Reports Server (NTRS)
Williams, Glenn L.
2009-01-01
A proposed method of modulating a sinusoidal carrier signal to convey digital information involves the use of histograms representing probability density functions (PDFs) that characterize samples of the signal waveform. The method is based partly on the observation that when a waveform is sampled (whether by analog or digital means) over a time interval at least as long as one half cycle of the waveform, the samples can be sorted by frequency of occurrence, thereby constructing a histogram representing a PDF of the waveform during that time interval.
Time of flight system on a chip
NASA Technical Reports Server (NTRS)
Paschalidis, Nicholas P. (Inventor)
2006-01-01
A CMOS time-of-flight TOF system-on-a-chip SoC for precise time interval measurement with low power consumption and high counting rate has been developed. The analog and digital TOF chip may include two Constant Fraction Discriminators CFDs and a Time-to-Digital Converter TDC. The CFDs can interface to start and stop anodes through two preamplifiers and perform signal processing for time walk compensation (110). The TDC digitizes the time difference with reference to an off-chip precise external clock (114). One TOF output is an 11-bit digital word and a valid event trigger output indicating a valid event on the 11-bit output bus (116).
Generating nonlinear FM chirp radar signals by multiple integrations
Doerry, Armin W [Albuquerque, NM
2011-02-01
A phase component of a nonlinear frequency modulated (NLFM) chirp radar pulse can be produced by performing digital integration operations over a time interval defined by the pulse width. Each digital integration operation includes applying to a respectively corresponding input parameter value a respectively corresponding number of instances of digital integration.
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
NASA Astrophysics Data System (ADS)
Gladen, R. W.; Chirayath, V. A.; McDonald, A. D.; Fairchild, A. J.; Chrysler, M. D.; Imam, S. K.; Koymen, A. R.; Weiss, A. H.
We describe herein a digital data acquisition system for a time-of-flight Positron annihilation-induced Auger Electron Spectrometer. This data acquisition system consists of a high-speed digitizer collecting signals induced by Auger electrons and annihilation gammas in a multi-channel plate electron detector and a BaF2 gamma detector, respectively. The time intervals between these two signals is used to determine the times of flight of the Auger electrons, which are analyzed by algorithms based on traditional nuclear electronics methods. Ultimately, this digital data acquisition system will be expanded to incorporate the first coincidence measurements of Auger electron and annihilation gamma energies.
A digital indicator for maximum windspeeds.
William B. Fowler
1969-01-01
A simple device for indicating maximum windspeed during a time interval is described. Use of a unijunction transistor, for voltage sensing, results in a stable comparison circuit and also reduces overall component requirements. Measurement is presented digitally in 1-mile-per-hour increments over the range of 0-51 m.p.h.
MULTIPLE INPUT BINARY ADDER EMPLOYING MAGNETIC DRUM DIGITAL COMPUTING APPARATUS
Cooke-Yarborough, E.H.
1960-12-01
A digital computing apparatus is described for adding a plurality of multi-digit binary numbers. The apparatus comprises a rotating magnetic drum, a recording head, first and second reading heads disposed adjacent to the first and second recording tracks, and a series of timing signals recorded on the first track. A series of N groups of digit-representing signals is delivered to the recording head at time intervals corresponding to the timing signals, each group consisting of digits of the same significance in the numbers, and the signal series is recorded on the second track of the drum in synchronism with the timing signals on the first track. The multistage registers are stepped cyclically through all positions, and each of the multistage registers is coupled to the control lead of a separate gate circuit to open the corresponding gate at only one selected position in each cycle. One of the gates has its input coupled to the bistable element to receive the sum digit, and the output lead of this gate is coupled to the recording device. The inputs of the other gates receive the digits to be added from the second reading head, and the outputs of these gates are coupled to the adding register. A phase-setting pulse source is connected to each of the multistage registers individually to step the multistage registers to different initial positions in the cycle, and the phase-setting pulse source is actuated each N time interval to shift a sum digit to the bistable element, where the multistage register coupled to bistable element is operated by the phase- setting pulse source to that position in its cycle N steps before opening the first gate, so that this gate opens in synchronism with each of the shifts to pass the sum digits to the recording head.
1985-02-28
psychophysiological function in question. For example, for most measurements of the cardiovascular system, data are available only at each heart beat ...function of the duration of the charging period, *i . and hence will be proportional to the inter- beat interval (and inversely °°. • .*~* 14 information (0... beat interval. Thus, the output will lag the input. 2.3 Computer Access to Voltage x Time Functions 2.3.1 Digital Input and Analog-to-Digital Conversion
NASA Technical Reports Server (NTRS)
Peslen, C. A.
1979-01-01
The impact of 5 minute interval SMS-2 visible digital image data in analyzing severe local storms is examined using wind vectors derived from cloud tracking on time lapsed sequence of geosynchronous satellite images. The cloud tracking areas are located in the Central Plains, where on 6 May 1975, hail-producing thunderstorms occurred ahead of a well defined dry line. The results demonstrate that satellite-derived wind vectors and their associated divergence fields complement conventional meteorological analyses in describing the conditions preceding severe local storm development.
Access Control to Information in Pervasive Computing Environments
2005-08-01
for foo’s public key. (Digital signatures are omitted.) indicate a set of location and time intervals. A service will return location information only...stands for foo’s public key. (Digital signatures are omitted.) it describes the resource to which access is granted. Currently, we allow only resources...information relationship. Alice’s location information is bun- dled in her personal information. (The digital signature is omitted.) We use extended
Multiple-Frequency Ultrasonic Pulse-Echo Display System.
1982-09-28
will sweep across some time interval. Adjust the ramp rate potentiometer to set this interval to exactly 10 ps. Ramp Delay None Set time base to 1.0 lis...the function keys. The table is a printout which results F.irectly from exercising Program KEE, listed in Appendix C-I. Note that "(ESC)B" refers to...flag +21 ŕ" = one-time flag (nessage is presented prior to full plot once per session) +22 time- base duration code +23 (High order digit) +24 * +25
van Bommel, Rob M G; Weber, Roy; Voogd, Adri C; Nederend, Joost; Louwman, Marieke W J; Venderink, Dick; Strobbe, Luc J A; Rutten, Matthieu J C; Plaisier, Menno L; Lohle, Paul N; Hooijen, Marianne J H; Tjan-Heijnen, Vivianne C G; Duijm, Lucien E M
2017-05-05
To determine the proportion of "true" interval cancers and tumor characteristics of interval breast cancers prior to, during and after the transition from screen-film mammography screening (SFM) to full-field digital mammography screening (FFDM). We included all women with interval cancers detected between January 2006 and January 2014. Breast imaging reports, biopsy results and breast surgery reports of all women recalled at screening mammography and of all women with interval breast cancers were collected. Two experienced screening radiologists reviewed the diagnostic mammograms, on which the interval cancers were diagnosed, as well as the prior screening mammograms and determined whether or not the interval cancer had been missed on the most recent screening mammogram. If not missed, the cancer was considered an occult ("true") interval cancer. A total of 442 interval cancers had been diagnosed, of which 144 at SFM with a prior SFM (SFM-SFM), 159 at FFDM with a prior SFM (FFDM-SFM) and 139 at FFDM with a prior FFDM (FFDM-FFDM). The transition from SFM to FFDM screening resulted in the diagnosis of more occult ("true") interval cancers at FFDM-SFM than at SFM-SFM (65.4% (104/159) versus 49.3% (71/144), P < 0.01), but this increase was no longer statistically significant in women who had been screened digitally for the second time (57.6% (80/139) at FFDM-FFDM versus 49.3% (71/144) at SFM-SFM). Tumor characteristics were comparable for the three interval cancer cohorts, except of a lower porportion (75.7 and 78.0% versus 67.2% af FFDM-FFDM, P < 0.05) of invasive ductal cancers at FFDM with prior FFDM. An increase in the proportion of occult interval cancers is observed during the transition from SFM to FFDM screening mammography. However, this increase seems temporary and is no longer detectable after the second round of digital screening. Tumor characteristics and type of surgery are comparable for interval cancers detected prior to, during and after the transition from SFM to FFDM screening mammography, except of a lower proportion of invasive ductal cancers after the transition.
Baker, John [Walnut Creek, CA; Archer, Daniel E [Knoxville, TN; Luke, Stanley John [Pleasanton, CA; Decman, Daniel J [Livermore, CA; White, Gregory K [Livermore, CA
2009-06-23
A tailpulse signal generating/simulating apparatus, system, and method designed to produce electronic pulses which simulate tailpulses produced by a gamma radiation detector, including the pileup effect caused by the characteristic exponential decay of the detector pulses, and the random Poisson distribution pulse timing for radioactive materials. A digital signal process (DSP) is programmed and configured to produce digital values corresponding to pseudo-randomly selected pulse amplitudes and pseudo-randomly selected Poisson timing intervals of the tailpulses. Pulse amplitude values are exponentially decayed while outputting the digital value to a digital to analog converter (DAC). And pulse amplitudes of new pulses are added to decaying pulses to simulate the pileup effect for enhanced realism in the simulation.
Jacobsohn, D.H.; Merrill, L.C.
1959-01-20
An improved parallel addition unit is described which is especially adapted for use in electronic digital computers and characterized by propagation of the carry signal through each of a plurality of denominationally ordered stages within a minimum time interval. In its broadest aspects, the invention incorporates a fast multistage parallel digital adder including a plurality of adder circuits, carry-propagation circuit means in all but the most significant digit stage, means for conditioning each carry-propagation circuit during the time period in which information is placed into the adder circuits, and means coupling carry-generation portions of thc adder circuit to the carry propagating means.
NASA Astrophysics Data System (ADS)
Wang, Yonggang; Liu, Chong
2016-10-01
The common solution for a field programmable gate array (FPGA)-based time-to-digital converter (TDC) is constructing a tapped delay line (TDL) for time interpolation to yield a sub-clock time resolution. The granularity and uniformity of the delay elements of TDL determine the TDC time resolution. In this paper, we propose a dual-sampling TDL architecture and a bin decimation method that could make the delay elements as small and uniform as possible, so that the implemented TDCs can achieve a high time resolution beyond the intrinsic cell delay. Two identical full hardware-based TDCs were implemented in a Xilinx UltraScale FPGA for performance evaluation. For fixed time intervals in the range from 0 to 440 ns, the average time-interval RMS resolution is measured by the two TDCs with 4.2 ps, thus the timestamp resolution of single TDC is derived as 2.97 ps. The maximum hit rate of the TDC is as high as half the system clock rate of FPGA, namely 250 MHz in our demo prototype. Because the conventional online bin-by-bin calibration is not needed, the implementation of the proposed TDC is straightforward and relatively resource-saving.
Architecture for a 1-GHz Digital RADAR
NASA Technical Reports Server (NTRS)
Mallik, Udayan
2011-01-01
An architecture for a Direct RF-digitization Type Digital Mode RADAR was developed at GSFC in 2008. Two variations of a basic architecture were developed for use on RADAR imaging missions using aircraft and spacecraft. Both systems can operate with a pulse repetition rate up to 10 MHz with 8 received RF samples per pulse repetition interval, or at up to 19 kHz with 4K received RF samples per pulse repetition interval. The first design describes a computer architecture for a Continuous Mode RADAR transceiver with a real-time signal processing and display architecture. The architecture can operate at a high pulse repetition rate without interruption for an infinite amount of time. The second design describes a smaller and less costly burst mode RADAR that can transceive high pulse repetition rate RF signals without interruption for up to 37 seconds. The burst-mode RADAR was designed to operate on an off-line signal processing paradigm. The temporal distribution of RF samples acquired and reported to the RADAR processor remains uniform and free of distortion in both proposed architectures. The majority of the RADAR's electronics is implemented in digital CMOS (complementary metal oxide semiconductor), and analog circuits are restricted to signal amplification operations and analog to digital conversion. An implementation of the proposed systems will create a 1-GHz, Direct RF-digitization Type, L-Band Digital RADAR--the highest band achievable for Nyquist Rate, Direct RF-digitization Systems that do not implement an electronic IF downsample stage (after the receiver signal amplification stage), using commercially available off-the-shelf integrated circuits.
ERIC Educational Resources Information Center
Lannie, Amanda L.; Martens, Brian K.
2008-01-01
Four fifth-grade students were presented with frustration-level math probes while three performance dimensions were measured (i.e., percent intervals on-task, percent correct digits, and digits correct per minute (DCM)). Using a multiple baseline design across participants, students were trained to self-monitor time on-task, accuracy, and…
CMOS direct time interval measurement of long-lived luminescence lifetimes.
Yao, Lei; Yung, Ka Yi; Cheung, Maurice C; Chodavarapu, Vamsy P; Bright, Frank V
2011-01-01
We describe a Complementary Metal-Oxide Semiconductor (CMOS) Direct Time Interval Measurement (DTIM) Integrated Circuit (IC) to detect the decay (fall) time of the luminescence emission when analyte-sensitive luminophores are excited with an optical pulse. The CMOS DTIM IC includes 14 × 14 phototransistor array, transimpedance amplifier, regulated gain amplifier, fall time detector, and time-to-digital convertor. We examined the DTIM system to measure the emission lifetime of oxygen-sensitive luminophores tris(4,7-diphenyl-1, 10-phenanthroline) ruthenium(II) ([Ru(dpp)(3)](2+)) encapsulated in sol-gel derived xerogel thin-films. The DTIM system fabricated using TSMC 0.35 μm process functions to detect lifetimes from 4 μs to 14.4 μs but can be tuned to detect longer lifetimes. The system provides 8-bit digital output proportional to lifetimes and consumes 4.5 mW of power with 3.3 V DC supply. The CMOS system provides a useful platform for the development of reliable, robust, and miniaturized optical chemical sensors.
Precise Interval Timer for Software Defined Radio
NASA Technical Reports Server (NTRS)
Pozhidaev, Aleksey (Inventor)
2014-01-01
A precise digital fractional interval timer for software defined radios which vary their waveform on a packet-by-packet basis. The timer allows for variable length in the preamble of the RF packet and allows to adjust boundaries of the TDMA (Time Division Multiple Access) Slots of the receiver of an SDR based on the reception of the RF packet of interest.
Real time automated inspection
Fant, Karl M.; Fundakowski, Richard A.; Levitt, Tod S.; Overland, John E.; Suresh, Bindinganavle R.; Ulrich, Franz W.
1985-01-01
A method and apparatus relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges are segmented out by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections.
Investigating Changes in the High-Latitude Topside Ionosphere During Large Magnetic Storms
NASA Technical Reports Server (NTRS)
Fainberg, Joseph; Benson, Robert F.; Osherovich, Vladimir; Truhlik, Vladimir; Wang, Yongli; Fung, Shing; Bilitza, Dieter
2009-01-01
A search was conducted to locate periods of nearly simultaneous solar-wind and high latitude topside-ionospheric data during magnetic storms. The focus was on the 20-yr interval from 1965 to 1985 when both solar-wind and Alouette/ISIS topside-sounder data are potentially available. The search yielded 125 large magnetic storms (minimum Dst less than 100) and 280 moderate magnetic storms (minimum Dst between -60 and -100). Solar wind data were available for most, but not all, of these storms. A search of the available high-latitude topside electron-density Ne(h) profiles available from the National Space Science Data Center (NSSDC), both from manual inspection of 35-mm film ionograms in the 1960s and more recent auto-processing of ISIS-2 topside digital ionograms using the TOPIST software, during 9-day intervals associated with the 125 large magnetic storm minimum Dst times yielded the following results: 31 intervals had 10 or more manual-scaled profiles (21 intervals had more than 100 profiles and 5 of these had more than 1,000 profiles), and 34 intervals had 10 or more TOPIST profiles (2 intervals had more than 100 profiles). In addition, a search of the available Alouette-2, ISIS-1 and ISIS-2 digital ionograms during the above periods has yielded encouraging initial results in that many ISIS-1 ionograms were found for the early time intervals. Future work will include the search for 35-mm film ionograms during selected intervals. This presentation will illustrate the results of this investigation to date.
Bandwidth tunable microwave photonic filter based on digital and analog modulation
NASA Astrophysics Data System (ADS)
Zhang, Qi; Zhang, Jie; Li, Qiang; Wang, Yubing; Sun, Xian; Dong, Wei; Zhang, Xindong
2018-05-01
A bandwidth tunable microwave photonic filter based on digital and analog modulation is proposed and experimentally demonstrated. The digital modulation is used to broaden the effective gain spectrum and the analog modulation is to get optical lines. By changing the symbol rate of data pattern, the bandwidth is tunable from 50 MHz to 700 MHz. The interval of optical lines is set according to the bandwidth of gain spectrum which is related to the symbol rate. Several times of bandwidth increase are achieved compared to a single analog modulation and the selectivity of the response is increased by 3.7 dB compared to a single digital modulation.
Comparing bandwidth requirements for digital baseband signals.
NASA Technical Reports Server (NTRS)
Houts, R. C.; Green, T. A.
1972-01-01
This paper describes the relative bandwidth requirements of the common digital baseband signaling techniques used for data transmission. Bandwidth considerations include the percentage of total power in a properly encoded PN sequence passed at bandwidths of 0.5, 1, 2 and 3 times the reciprocal of the bit interval. The signals considered in this study are limited to the binary class. The study compares such signaling techniques as delay modulation, bipolar, biternary, duobinary, pair selected ternary and time polarity control in addition to the conventional NRZ, RZ and BI-phi schemes.
Real time automated inspection
Fant, K.M.; Fundakowski, R.A.; Levitt, T.S.; Overland, J.E.; Suresh, B.R.; Ulrich, F.W.
1985-05-21
A method and apparatus are described relating to the real time automatic detection and classification of characteristic type surface imperfections occurring on the surfaces of material of interest such as moving hot metal slabs produced by a continuous steel caster. A data camera transversely scans continuous lines of such a surface to sense light intensities of scanned pixels and generates corresponding voltage values. The voltage values are converted to corresponding digital values to form a digital image of the surface which is subsequently processed to form an edge-enhanced image having scan lines characterized by intervals corresponding to the edges of the image. The edge-enhanced image is thresholded to segment out the edges and objects formed by the edges by interval matching and bin tracking. Features of the objects are derived and such features are utilized to classify the objects into characteristic type surface imperfections. 43 figs.
Sea-level evaluation of digitally implemented turbojet engine control functions
NASA Technical Reports Server (NTRS)
Arpasi, D. J.; Cwynar, D. S.; Wallhagen, R. E.
1972-01-01
The standard hydromechanical control system of a turbojet engine was replaced with a digital control system that implemented the same control laws. A detailed discussion of the digital control system in use with the engine is presented. The engine was operated in a sea-level test stand. The effects of control update interval are defined, and a method for extending this interval by using digital compensation is discussed.
Digitization of Electrocardiogram From Telemetry Prior to In-hospital Cardiac Arrest: A Pilot Study.
Attin, Mina; Wang, Lu; Soroushmehr, S M Reza; Lin, Chii-Dean; Lemus, Hector; Spadafore, Maxwell; Najarian, Kayvan
2016-03-01
Analyzing telemetry electrocardiogram (ECG) data over an extended period is often time-consuming because digital records are not widely available at hospitals. Investigating trends and patterns in the ECG data could lead to establishing predictors that would shorten response time to in-hospital cardiac arrest (I-HCA). This study was conducted to validate a novel method of digitizing paper ECG tracings from telemetry systems in order to facilitate the use of heart rate as a diagnostic feature prior to I-HCA. This multicenter study used telemetry to investigate full-disclosure ECG papers of 44 cardiovascular patients obtained within 1 hr of I-HCA with initial rhythms of pulseless electrical activity and asystole. Digital ECGs were available for seven of these patients. An algorithm to digitize the full-disclosure ECG papers was developed using the shortest path method. The heart rate was measured manually (averaging R-R intervals) for ECG papers and automatically for digitized and digital ECGs. Significant correlations were found between manual and automated measurements of digitized ECGs (p < .001) and between digitized and digital ECGs (p < .001). Bland-Altman methods showed bias = .001 s, SD = .0276 s, lower and upper 95% limits of agreement for digitized and digital ECGs = .055 and -.053 s, and percentage error = 0.22%. Root mean square (rms), percentage rms difference, and signal to noise ratio values were in acceptable ranges. The digitization method was validated. Digitized ECG provides an efficient and accurate way of measuring heart rate over an extended period of time. © The Author(s) 2015.
Martin, A.D.
1986-05-09
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay provides a first output signal at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits latch the high resolution data to form a first synchronizing data set. A selected time interval has been preset to internal counters and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses count down the counters to generate an internal pulse delayed by an internal which is functionally related to the preset time interval. A second LCD corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD to generate a second set of synchronizing data which is complementary with the first set of synchronizing data for presentation to logic circuits. The logic circuits further delay the internal output signal with the internal pulses. The final delayed output signal thereafter enables the output pulse generator to produce the desired output pulse at the preset time delay interval following input of the trigger pulse.
Interference-Detection Module in a Digital Radar Receiver
NASA Technical Reports Server (NTRS)
Fischman, Mark; Berkun, Andrew; Chu, Anhua; Freedman, Adam; Jourdan, Michael; McWatters, Dalia; Paller, Mimi
2009-01-01
A digital receiver in a 1.26-GHz spaceborne radar scatterometer now undergoing development includes a module for detecting radio-frequency interference (RFI) that could contaminate scientific data intended to be acquired by the scatterometer. The role of the RFI-detection module is to identify time intervals during which the received signal is likely to be contaminated by RFI and thereby to enable exclusion, from further scientific data processing, of signal data acquired during those intervals. The underlying concepts of detection of RFI and rejection of RFI-contaminated signal data are also potentially applicable in advanced terrestrial radio receivers, including software-defined radio receivers in general, receivers in cellular telephones and other wireless consumer electronic devices, and receivers in automotive collision-avoidance radar systems.
NASA Astrophysics Data System (ADS)
Shi, Jing; Ausloos, Marcel; Zhu, Tingting
2018-02-01
We discuss a common suspicion about reported financial data, in 10 industrial sectors of the 6 so called "main developing countries" over the time interval [2000-2014]. These data are examined through Benford's law first significant digit and through distribution distances tests. It is shown that several visually anomalous data have to be a priori removed. Thereafter, the distributions much better follow the first digit significant law, indicating the usefulness of a Benford's law test from the research starting line. The same holds true for distance tests. A few outliers are pointed out.
Keefe, Donald J.
1980-01-01
An automatically sweeping circuit for searching for an evoked response in an output signal in time with respect to a trigger input. Digital counters are used to activate a detector at precise intervals, and monitoring is repeated for statistical accuracy. If the response is not found then a different time window is examined until the signal is found.
Evaluation of using digital gravity field models for zoning map creation
NASA Astrophysics Data System (ADS)
Loginov, Dmitry
2018-05-01
At the present time the digital cartographic models of geophysical fields are taking a special significance into geo-physical mapping. One of the important directions to their application is the creation of zoning maps, which allow taking into account the morphology of geophysical field in the implementation automated choice of contour intervals. The purpose of this work is the comparative evaluation of various digital models in the creation of integrated gravity field zoning map. For comparison were chosen the digital model of gravity field of Russia, created by the analog map with scale of 1 : 2 500 000, and the open global model of gravity field of the Earth - WGM2012. As a result of experimental works the four integrated gravity field zoning maps were obtained with using raw and processed data on each gravity field model. The study demonstrates the possibility of open data use to create integrated zoning maps with the condition to eliminate noise component of model by processing in specialized software systems. In this case, for solving problem of contour intervals automated choice the open digital models aren't inferior to regional models of gravity field, created for individual countries. This fact allows asserting about universality and independence of integrated zoning maps creation regardless of detail of a digital cartographic model of geo-physical fields.
Test-retest reliability and practice effects of a rapid screen of mild traumatic brain injury.
De Monte, Veronica Eileen; Geffen, Gina Malke; Kwapil, Karleigh
2005-07-01
Test-retest reliabilities and practice effects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice effects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.
Development of microcontroller based water flow measurement
NASA Astrophysics Data System (ADS)
Munir, Muhammad Miftahul; Surachman, Arif; Fathonah, Indra Wahyudin; Billah, Muhammad Aziz; Khairurrijal, Mahfudz, Hernawan; Rimawan, Ririn; Lestari, Slamet
2015-04-01
A digital instrument for measuring water flow was developed using an AT89S52 microcontroller, DS1302 real time clock (RTC), and EEPROM for an external memory. The sensor used for probing the current was a propeller that will rotate if immersed in a water flow. After rotating one rotation, the sensor sends one pulse and the number of pulses are counted for a certain time of counting. The measurement data, i.e. the number of pulses per unit time, are converted into water flow velocity (m/s) through a mathematical formula. The microcontroller counts the pulse sent by the sensor and the number of counted pulses are stored into the EEPROM memory. The time interval for counting is provided by the RTC and can be set by the operator. The instrument was tested under various time intervals ranging from 10 to 40 seconds and several standard propellers owned by Experimental Station for Hydraulic Structure and Geotechnics (BHGK), Research Institute for Water Resources (Pusair). Using the same propellers and water flows, it was shown that water flow velocities obtained from the developed digital instrument and those found by the provided analog one are almost similar.
A fast-locking all-digital delay-locked loop for phase/delay generation in an FPGA
NASA Astrophysics Data System (ADS)
Zhujia, Chen; Haigang, Yang; Fei, Liu; Yu, Wang
2011-10-01
A fast-locking all-digital delay-locked loop (ADDLL) is proposed for the DDR SDRAM controller interface in a field programmable gate array (FPGA). The ADDLL performs a 90° phase-shift so that the data strobe (DQS) can enlarge the data valid window in order to minimize skew. In order to further reduce the locking time and to prevent the harmonic locking problem, a time-to-digital converter (TDC) is proposed. A duty cycle corrector (DCC) is also designed in the ADDLL to adjust the output duty cycle to 50%. The ADDLL, implemented in a commercial 0.13 μm CMOS process, occupies a total of 0.017 mm2 of active area. Measurement results show that the ADDLL has an operating frequency range of 75 to 350 MHz and a total delay resolution of 15 ps. The time interval error (TIE) of the proposed circuit is 60.7 ps.
A high-resolution time-to-digital converter using a three-level resolution
NASA Astrophysics Data System (ADS)
Dehghani, Asma; Saneei, Mohsen; Mahani, Ali
2016-08-01
In this article, a three-level resolution Vernier delay line time-to-digital converter (TDC) was proposed. The proposed TDC core was based on the pseudo-differential digital architecture that made it insensitive to nMOS and pMOS transistor mismatches. It also employed a Vernier delay line (VDL) in conjunction with an asynchronous read-out circuitry. The time interval resolution was equal to the difference of delay between buffers of upper and lower chains. Then, via the extra chain included in the lower delay line, resolution was controlled and power consumption was reduced. This method led to high resolution and low power consumption. The measurement results of TDC showed a resolution of 4.5 ps, 12-bit output dynamic range, and integral nonlinearity of 1.5 least significant bits. This TDC achieved the consumption of 68.43 µW from 1.1-V supply.
Longman, Cai S; Lavric, Aureliu; Monsell, Stephen
2017-06-01
The performance overhead associated with changing tasks (the "switch cost") usually diminishes when the task is specified in advance but is rarely eliminated by preparation. A popular account of the "residual" (asymptotic) switch cost is that it reflects "task-set inertia": carry-over of task-set parameters from the preceding trial(s). New evidence for a component of "task-set inertia" comes from eye-tracking, where the location associated with the previously (but no longer) relevant task is fixated preferentially over other irrelevant locations, even when preparation intervals are generous. Might such limits in overcoming task-set inertia in general, and "attentional inertia" in particular, result from suboptimal scheduling of preparation when the time available is outside one's control? In the present study, the stimulus comprised 3 digits located at the points of an invisible triangle, preceded by a central verbal cue specifying which of 3 classification tasks to perform, each consistently applied to just 1 digit location. The digits were presented only when fixation moved away from the cue, thus giving the participant control over preparation time. In contrast to our previous research with experimenter-determined preparation intervals, we found no sign of attentional inertia for the long preparation intervals. Self-paced preparation reduced but did not eliminate the performance switch cost-leaving a clear residual component in both reaction time and error rates. That the scheduling of preparation accounts for some, but not all, components of the residual switch cost, challenges existing accounts of the switch cost, even those which distinguish between preparatory and poststimulus reconfiguration processes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Hart, George W.; Kern, Jr., Edward C.
1987-06-09
An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.
Hart, G.W.; Kern, E.C. Jr.
1987-06-09
An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.
Single photon detection and timing in the Lunar Laser Ranging Experiment.
NASA Technical Reports Server (NTRS)
Poultney, S. K.
1972-01-01
The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.
NASA Technical Reports Server (NTRS)
Adelfang, S. I.
1978-01-01
A statistical analysis is presented of the temporal variability of wind vectors at 1 km altitude intervals from 0 to 27 km altitude after applying a digital filter to the original wind profile data sample.
High resolution digital delay timer
Martin, Albert D.
1988-01-01
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay (20) provides a first output signal (24) at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits (26, 28) latch the high resolution data (24) to form a first synchronizing data set (60). A selected time interval has been preset to internal counters (142, 146, 154) and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses (32, 34) count down the counters to generate an internal pulse delayed by an interval which is functionally related to the preset time interval. A second LCD (184) corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD (74) to generate a second set of synchronizing data (76) which is complementary with the first set of synchronizing data (60) for presentation to logic circuits (64). The logic circuits (64) further delay the internal output signal (72) to obtain a proper phase relationship of an output signal (80) with the internal pulses (32, 34). The final delayed output signal (80) thereafter enables the output pulse generator (82) to produce the desired output pulse (84) at the preset time delay interval following input of the trigger pulse (10, 12).
Kligfield, Paul; Badilini, Fabio; Rowlandson, Ian; Xue, Joel; Clark, Elaine; Devine, Brian; Macfarlane, Peter; de Bie, Johan; Mortara, David; Babaeizadeh, Saeed; Gregg, Richard; Helfenbein, Eric D; Green, Cynthia L
2014-02-01
Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs. Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium. Included were 3 groups based on expected QT interval and degree of repolarization abnormality, comprising 200 ECGs each from (1) placebo or baseline study period in normal subjects during thorough QT studies, (2) peak moxifloxacin effect in otherwise normal subjects during thorough QT studies, and (3) patients with genotyped variants of congenital long QT syndrome (LQTS). Differences of means between manufacturers were generally small in the normal and moxifloxacin subjects, but in the LQTS patients, differences of means ranged from 2.0 to 14.0 ms for QRS duration and from 0.8 to 18.1 ms for the QT interval. Mean absolute differences between algorithms were similar for QRS duration and QT intervals in the normal and in the moxifloxacin subjects (mean ≤6 ms) but were significantly larger in patients with LQTS. Small but statistically significant group differences in mean interval and duration measurements and means of individual absolute differences exist among automated algorithms of widely used, current generation digital electrocardiographs. Measurement differences, including QRS duration and the QT interval, are greatest for the most abnormal ECGs. © 2014.
Data system for multiplexed water-current meters
NASA Technical Reports Server (NTRS)
Ramsey, C. R.
1977-01-01
Flow rates at 32 flood plain locations are measured simultaneously by single digital logic unit with high noise immunity. Water flowing through pygmy current meters rotates element that closes electrical contact once every resolution, so flow rate is measured by counting number of closures in time interval.
Eades, Susan C; Stokes, Ashley M; Johnson, Philip J; LeBlanc, Casey J; Ganjam, Venkataseshu K; Buff, Preston R; Moore, Rustin M
2007-01-01
To quantify changes in endothelium-derived factors and relate those changes to various aspects of digital hemodynamics during the prodromal stages of carbohydrate overload (CHO)-induced laminitis in horses. 20 adult horses without abnormalities of the digit. Digital and jugular venous blood samples were collected at 1-hour intervals (for assessment of endothelin-1 [ET-1] immunoreactivity and measurement of glucose, insulin, and nitric oxide [NO] concentrations) or 4-hour intervals (CBC and platelet-neutrophil aggregate assessment) for 8 hours or 16 hours after induction of CHO-associated laminitis in horses treated with an ET-1 antagonist. Effects of treatment, collection site, and time and the random effects of horse on each variable were analyzed by use of a repeated-measures model. Where treatment and collection site had no significant effect, data were combined. Compared with baseline values, CHO resulted in changes in several variables, including a significant increase from baseline in digital blood ET-like immunoreactivity at 11 hours; digital blood ET-like immunoreactivity was significantly greater than that in jugular venous blood at 8, 9, 11, and 12 hours. Digital and jugular venous blood concentrations of glucose increased from baseline significantly at 3, 4, and 5 hours; insulin concentration increased significantly at 5 hours; and the number of platelet-neutrophil aggregates increased significantly at 12 hours. In horses, concurrent increases in venous blood ET-1 immunoreactivity, insulin and glucose concentrations, and platelet-neutrophil aggregates support a role of endothelial dysfunction in the pathogenesis of CHO-induced laminitis.
NASA Astrophysics Data System (ADS)
Erwin, E. H.; Coffey, H. E.; Denig, W. F.; Willis, D. M.; Henwood, R.; Wild, M. N.
2013-11-01
A new sunspot and faculae digital dataset for the interval 1874 - 1955 has been prepared under the auspices of the NOAA National Geophysical Data Center (NGDC). This digital dataset contains measurements of the positions and areas of both sunspots and faculae published initially by the Royal Observatory, Greenwich, and subsequently by the Royal Greenwich Observatory (RGO), under the title Greenwich Photo-heliographic Results ( GPR) , 1874 - 1976. Quality control (QC) procedures based on logical consistency have been used to identify the more obvious errors in the RGO publications. Typical examples of identifiable errors are North versus South errors in specifying heliographic latitude, errors in specifying heliographic (Carrington) longitude, errors in the dates and times, errors in sunspot group numbers, arithmetic errors in the summation process, and the occasional omission of solar ephemerides. Although the number of errors in the RGO publications is remarkably small, an initial table of necessary corrections is provided for the interval 1874 - 1917. Moreover, as noted in the preceding companion papers, the existence of two independently prepared digital datasets, which both contain information on sunspot positions and areas, makes it possible to outline a preliminary strategy for the development of an even more accurate digital dataset. Further work is in progress to generate an extremely reliable sunspot digital dataset, based on the long programme of solar observations supported first by the Royal Observatory, Greenwich, and then by the Royal Greenwich Observatory.
BOREAS Level-0 ER-2 Navigation Data
NASA Technical Reports Server (NTRS)
Strub, Richard; Dominguez, Roseanne; Newcomer, Jeffrey A.; Hall, Forrest G. (Editor)
2000-01-01
The BOREAS Staff Science effort covered those activities that were BOREAS community-level activities or required uniform data collection procedures across sites and time. These activities included the acquisition, processing, and archiving of aircraft navigation/attitude data to complement the digital image data. The level-0 ER-2 navigation data files contain aircraft attitude and position information acquired during the digital image and photographic data collection missions. Temporally, the data were acquired from April to September 1994. Data were recorded at intervals of 5 seconds. The data are stored in tabular ASCII files.
Precise time technology for selected Air Force systems: Present status and future requirements
NASA Technical Reports Server (NTRS)
Yannoni, N. F.
1981-01-01
Precise time and time interval (PTTI) technology is becoming increasingly significant to Air Force operations as digital techniques find expanded utility in military missions. Timing has a key role in the function as well as in navigation. A survey of the PTTI needs of several Air Force systems is presented. Current technology supporting these needs was reviewed and new requirements are emphasized for systems as they transfer from initial development to final operational deployment.
Rath, Timo; Tontini, Gian E; Nägel, Andreas; Vieth, Michael; Zopf, Steffen; Günther, Claudia; Hoffman, Arthur; Neurath, Markus F; Neumann, Helmut
2015-10-22
Distal diminutive colorectal polyps are common and accurate endoscopic prediction of hyperplastic or adenomatous polyp histology could reduce procedural time, costs and potential risks associated with the resection. Within this study we assessed whether digital chromoendoscopy can accurately predict the histology of distal diminutive colorectal polyps according to the ASGE PIVI statement. In this prospective cohort study, 224 consecutive patients undergoing screening or surveillance colonoscopy were included. Real time histology of 121 diminutive distal colorectal polyps was evaluated using high-definition endoscopy with digital chromoendoscopy and the accuracy of predicting histology with digital chromoendoscopy was assessed. The overall accuracy of digital chromoendoscopy for prediction of adenomatous polyp histology was 90.1 %. Sensitivity, specificity, positive and negative predictive values were 93.3, 88.7, 88.7, and 93.2 %, respectively. In high-confidence predictions, the accuracy increased to 96.3 % while sensitivity, specificity, positive and negative predictive values were calculated as 98.1, 94.4, 94.5, and 98.1 %, respectively. Surveillance intervals with digital chromoendoscopy were correctly predicted with >90 % accuracy. High-definition endoscopy in combination with digital chromoendoscopy allowed real-time in vivo prediction of distal colorectal polyp histology and is accurate enough to leave distal colorectal polyps in place without resection or to resect and discard them without pathologic assessment. This approach has the potential to reduce costs and risks associated with the redundant removal of diminutive colorectal polyps. ClinicalTrials NCT02217449.
A digital acquisition and elaboration system for nuclear fast pulse detection
NASA Astrophysics Data System (ADS)
Esposito, B.; Riva, M.; Marocco, D.; Kaschuck, Y.
2007-03-01
A new digital acquisition and elaboration system has been developed and assembled in ENEA-Frascati for the direct sampling of fast pulses from nuclear detectors such as scintillators and diamond detectors. The system is capable of performing the digital sampling of the pulses (200 MSamples/s, 14-bit) and the simultaneous (compressed) data transfer for further storage and software elaboration. The design (FPGA-based) is oriented to real-time applications and has been developed in order to allow acquisition with no loss of pulses and data storage for long-time intervals (tens of s at MHz pulse count rates) without the need of large on-board memory. A dedicated pulse analysis software, written in LabVIEWTM, performs the treatment of the acquired pulses, including pulse recognition, pile-up rejection, baseline removal, pulse shape particle separation and pulse height spectra analysis. The acquisition and pre-elaboration programs have been fully integrated with the analysis software.
MICROPROCESSOR-BASED DATA-ACQUISITION SYSTEM FOR A BOREHOLE RADAR.
Bradley, Jerry A.; Wright, David L.
1987-01-01
An efficient microprocessor-based system is described that permits real-time acquisition, stacking, and digital recording of data generated by a borehole radar system. Although the system digitizes, stacks, and records independently of a computer, it is interfaced to a desktop computer for program control over system parameters such as sampling interval, number of samples, number of times the data are stacked prior to recording on nine-track tape, and for graphics display of the digitized data. The data can be transferred to the desktop computer during recording, or it can be played back from a tape at a latter time. Using the desktop computer, the operator observes results while recording data and generates hard-copy graphics in the field. Thus, the radar operator can immediately evaluate the quality of data being obtained, modify system parameters, study the radar logs before leaving the field, and rerun borehole logs if necessary. The system has proven to be reliable in the field and has increased productivity both in the field and in the laboratory.
NASA Astrophysics Data System (ADS)
Beach, Shaun E.; Semkow, Thomas M.; Remling, David J.; Bradt, Clayton J.
2017-07-01
We have developed accessible methods to demonstrate fundamental statistics in several phenomena, in the context of teaching electronic signal processing in a physics-based college-level curriculum. A relationship between the exponential time-interval distribution and Poisson counting distribution for a Markov process with constant rate is derived in a novel way and demonstrated using nuclear counting. Negative binomial statistics is demonstrated as a model for overdispersion and justified by the effect of electronic noise in nuclear counting. The statistics of digital packets on a computer network are shown to be compatible with the fractal-point stochastic process leading to a power-law as well as generalized inverse Gaussian density distributions of time intervals between packets.
NASA Astrophysics Data System (ADS)
Karasawa, Yoshio; Kumagai, Taichi; Takemoto, Atsushi; Fujii, Takeo; Ito, Kenji; Suzuki, Noriyoshi
A novel timing synchronizing scheme is proposed for use in inter-vehicle communication (IVC) with an autonomous distributed intelligent transport system (ITS). The scheme determines the timing of packet signal transmission in the IVC network and employs the guard interval (GI) timing in the orthogonal frequency divisional multiplexing (OFDM) signal currently used for terrestrial broadcasts in the Japanese digital television system (ISDB-T). This signal is used because it is expected that the automotive market will demand the capability for cars to receive terrestrial digital TV broadcasts in the near future. The use of broadcasts by automobiles presupposes that the on-board receivers are capable of accurately detecting the GI timing data in an extremely low carrier-to-noise ratio (CNR) condition regardless of a severe multipath environment which will introduce broad scatter in signal arrival times. Therefore, we analyzed actual broadcast signals received in a moving vehicle in a field experiment and showed that the GI timing signal is detected with the desired accuracy even in the case of extremely low-CNR environments. Some considerations were also given about how to use these findings.
The Effects of Numerical Magnitude, Size, and Color Saturation on Perceived Interval Duration
ERIC Educational Resources Information Center
Alards-Tomalin, Doug; Leboe-McGowan, Jason P.; Shaw, Joshua D. M.; Leboe-McGowan, Launa C.
2014-01-01
The relative magnitude (or intensity) of an event can have direct implications on timing estimation. Previous studies have found that greater magnitude stimuli are often reported as longer in duration than lesser magnitudes, including Arabic digits (Xuan, Zhang, He, & Chen, 2007). One explanation for these findings is that different…
Formation Flying Control Implementation in Highly Elliptical Orbits
NASA Technical Reports Server (NTRS)
Capo-Lugo, Pedro A.; Bainum, Peter M.
2009-01-01
The Tschauner-Hempel equations are widely used to correct the separation distance drifts between a pair of satellites within a constellation in highly elliptical orbits [1]. This set of equations was discretized in the true anomaly angle [1] to be used in a digital steady-state hierarchical controller [2]. This controller [2] performed the drift correction between a pair of satellites within the constellation. The objective of a discretized system is to develop a simple algorithm to be implemented in the computer onboard the satellite. The main advantage of the discrete systems is that the computational time can be reduced by selecting a suitable sampling interval. For this digital system, the amount of data will depend on the sampling interval in the true anomaly angle [3]. The purpose of this paper is to implement the discrete Tschauner-Hempel equations and the steady-state hierarchical controller in the computer onboard the satellite. This set of equations is expressed in the true anomaly angle in which a relation will be formulated between the time and the true anomaly angle domains.
Techniques for measuring arrival times of pulsar signals 1: DSN observations from 1968 to 1980
NASA Technical Reports Server (NTRS)
Downs, G. S.; Reichley, P. E.
1980-01-01
Techniques used in the ground based observations of pulsars are described, many of them applicable in a navigation scheme. The arrival times of the pulses intercepting Earth are measured at time intervals from a few days to a few months. Low noise, wide band receivers, amplify signals intercepted by 26 m, 34, and 64 m antennas. Digital recordings of total received signal power versus time are cross correlated with the appropriate pulse template.
NASA Astrophysics Data System (ADS)
Meng, X. T.; Levin, D. S.; Chapman, J. W.; Zhou, B.
2016-09-01
The ATLAS Muon Spectrometer endcap thin-Resistive Plate Chamber trigger project compliments the New Small Wheel endcap Phase-1 upgrade for higher luminosity LHC operation. These new trigger chambers, located in a high rate region of ATLAS, will improve overall trigger acceptance and reduce the fake muon trigger incidence. These chambers must generate a low level muon trigger to be delivered to a remote high level processor within a stringent latency requirement of 43 bunch crossings (1075 ns). To help meet this requirement the High Performance Time to Digital Converter (HPTDC), a multi-channel ASIC designed by CERN Microelectronics group, has been proposed for the digitization of the fast front end detector signals. This paper investigates the HPTDC performance in the context of the overall muon trigger latency, employing detailed behavioral Verilog simulations in which the latency in triggerless mode is measured for a range of configurations and under realistic hit rate conditions. The simulation results show that various HPTDC operational configurations, including leading edge and pair measurement modes can provide high efficiency (>98%) to capture and digitize hits within a time interval satisfying the Phase-1 latency tolerance.
NASA Astrophysics Data System (ADS)
Wang, Yonggang; Kuang, Jie; Liu, Chong; Cao, Qiang; Li, Deng
2017-03-01
A high performance multi-channel time-to-digital converter (TDC) is implemented in a Xilinx Zynq-7000 field programmable gate array (FPGA). It can be flexibly configured as either 32 TDC channels with 9.9 ps time-interval RMS precision, 16 TDC channels with 6.9 ps RMS precision, or 8 TDC channels with 5.8 ps RMS precision. All TDCs have a 380 M Samples/second measurement throughput and a 2.63 ns measurement dead time. The performance consistency and temperature dependence of TDC channels are also evaluated. Because Zynq-7000 FPGA family integrates a feature-rich dual-core ARM based processing system and 28 nm Xilinx programmable logic in a single device, the realization of high performance TDCs on it will make the platform more widely used in time-measuring related applications.
Intermittent/transient fault phenomena in digital systems
NASA Technical Reports Server (NTRS)
Masson, G. M.
1977-01-01
An overview of the intermittent/transient (IT) fault study is presented. An interval survivability evaluation of digital systems for IT faults is discussed along with a method for detecting and diagnosing IT faults in digital systems.
Xiong, Wenjun; Yu, Xinghuo; Chen, Yao; Gao, Jie
2017-06-01
This brief investigates the quantized iterative learning problem for digital networks with time-varying topologies. The information is first encoded as symbolic data and then transmitted. After the data are received, a decoder is used by the receiver to get an estimate of the sender's state. Iterative learning quantized communication is considered in the process of encoding and decoding. A sufficient condition is then presented to achieve the consensus tracking problem in a finite interval using the quantized iterative learning controllers. Finally, simulation results are given to illustrate the usefulness of the developed criterion.
Video Imaging System Particularly Suited for Dynamic Gear Inspection
NASA Technical Reports Server (NTRS)
Broughton, Howard (Inventor)
1999-01-01
A digital video imaging system that captures the image of a single tooth of interest of a rotating gear is disclosed. The video imaging system detects the complete rotation of the gear and divide that rotation into discrete time intervals so that each tooth of interest of the gear is precisely determined when it is at a desired location that is illuminated in unison with a digital video camera so as to record a single digital image for each tooth. The digital images are available to provide instantaneous analysis of the tooth of interest, or to be stored and later provide images that yield a history that may be used to predict gear failure, such as gear fatigue. The imaging system is completely automated by a controlling program so that it may run for several days acquiring images without supervision from the user.
Random digital encryption secure communication system
NASA Technical Reports Server (NTRS)
Doland, G. D. (Inventor)
1982-01-01
The design of a secure communication system is described. A product code, formed from two pseudorandom sequences of digital bits, is used to encipher or scramble data prior to transmission. The two pseudorandom sequences are periodically changed at intervals before they have had time to repeat. One of the two sequences is transmitted continuously with the scrambled data for synchronization. In the receiver portion of the system, the incoming signal is compared with one of two locally generated pseudorandom sequences until correspondence between the sequences is obtained. At this time, the two locally generated sequences are formed into a product code which deciphers the data from the incoming signal. Provision is made to ensure synchronization of the transmitting and receiving portions of the system.
NASA Astrophysics Data System (ADS)
Wang, Yonggang; Liu, Chong
2016-10-01
Field programmable gate arrays (FPGAs) manufactured with more advanced processing technology have faster carry chains and smaller delay elements, which are favorable for the design of tapped delay line (TDL)-style time-to-digital converters (TDCs) in FPGA. However, new challenges are posed in using them to implement TDCs with a high time precision. In this paper, we propose a bin realignment method and a dual-sampling method for TDC implementation in a Xilinx UltraScale FPGA. The former realigns the disordered time delay taps so that the TDC precision can approach the limit of its delay granularity, while the latter doubles the number of taps in the delay line so that the TDC precision beyond the cell delay limitation can be expected. Two TDC channels were implemented in a Kintex UltraScale FPGA, and the effectiveness of the new methods was evaluated. For fixed time intervals in the range from 0 to 440 ns, the average RMS precision measured by the two TDC channels reaches 5.8 ps using the bin realignment, and it further improves to 3.9 ps by using the dual-sampling method. The time precision has a 5.6% variation in the measured temperature range. Every part of the TDC, including dual-sampling, encoding, and on-line calibration, could run at a 500 MHz clock frequency. The system measurement dead time is only 4 ns.
Mental and physical activities delay cognitive decline in older persons with dementia.
Cheng, Sheung-Tak; Chow, Pizza K; Song, You-Qiang; Yu, Edwin C S; Chan, Alfred C M; Lee, Tatia M C; Lam, John H M
2014-01-01
To examine the effects of cognitive stimulation (mahjong) and physical exercise (tai chi [TC]) on cognitive performance in persons with dementia. Cluster-randomized open-label controlled design. Nursing homes. One hundred ten residents, most of whom were cholinesterase-inhibitor naive. Inclusion criteria were Mini-Mental State Examination (MMSE) = 10-24 and suffering from at least very mild dementia (Clinical Dementia Rating ≥ 0.5). Exclusion criteria were being bedbound, audio/visual impairment, regular activity participation before study, or contraindications for physical or group activities. Homes were randomized into three conditions (mahjong, TC, and simple handicrafts [control]). Activities were conducted three times weekly for 12 weeks. Primary outcome was MMSE. Secondary outcomes were immediate/delayed recall, categorical fluency, and digit span. Various biological risk factors, including apolipoprotein E ε4 allele, were included as covariates. Measures were collected at 0 (baseline), 3 (posttreatment), 6, and 9 months. Intent-to-treat analyses were performed using mixed-effects regression. Mahjong's effect varied by time for MMSE, delayed recall, and forward digit span. TC had similar effects but not for delayed recall. The typical pattern was that control participants deteriorated while mahjong and TC participants maintained their abilities over time, leading to enlarged treatment effects as time progressed. By 9 months, mahjong and TC differed from control by 4.5 points (95% confidence interval: 2.0-6.9; d = 0.48) and 3.7 points (95% confidence interval: 1.4-6.0; d = 0.40), respectively, on MMSE. No treatment effects were observed for immediate recall and backward digit span. Mahjong and TC can preserve functioning or delay decline in certain cognitive domains, even in those with significant cognitive impairment. Copyright © 2014 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.
Holmes, Layne C.; Gaughan, Earl M.; Gorondy, Denise A.; Hogge, Steve; Spire, Mark F.
2003-01-01
Infrared thermography is an imaging modality gaining popularity as a diagnostic aid in the evaluation of equine lameness. Anecdotal reports of skin hyperthermia induced by local anesthesia, detected by thermography, have been made; however, no controlled studies have been reported. The purpose of this study was to examine the effects of perineural anesthesia on infrared thermographic images of the forelimb digits in normal horses. After environmental acclimation, infrared thermographs were made at intervals of 0, 5, 10, 15, 30, and 45 min from administration of mepivacaine hydrochloride or phosphate buffered saline in 6 adult horses with no clinical evidence of abnormality of the forelimb digits. The mean limb surface temperatures were compared by 2-factor ANOVA. Results indicated no significant difference between treatments, time after injection, or an interaction of time and treatment. Infrared thermographic imaging apparently can be performed within 45 min of perineural mepivacaine hydrochloride anesthesia without risk of artifactual changes in limb surface temperature. PMID:12757130
Chauvenet, B; Bobin, C; Bouchard, J
2017-12-01
Dead-time correction formulae are established in the general case of superimposed non-homogeneous Poisson processes. Based on the same principles as conventional live-timed counting, this method exploits the additional information made available using digital signal processing systems, and especially the possibility to store the time stamps of live-time intervals. No approximation needs to be made to obtain those formulae. Estimates of the variances of corrected rates are also presented. This method is applied to the activity measurement of short-lived radionuclides. Copyright © 2017 Elsevier Ltd. All rights reserved.
Louis. R. Iverson; Paul. G. Risser; Paul. G. Risser
1987-01-01
Geographic information systems and remote sensing techniques are powerful tools in the analysis of long-term changes in vegetation and land use, especially because spatial information from two or more time intervals can be compared more readily than by manual methods. A primary restriction is the paucity of data that has been digitized from earlier periods. The...
Assessing the impact of PACS on patient care in a medical intensive care unit
NASA Astrophysics Data System (ADS)
Shile, Peter E.; Kundel, Harold L.; Seshadri, Sridhar B.; Carey, Bruce; Brikman, Inna; Kishore, Sheel; Feingold, Eric R.; Lanken, Paul N.
1993-09-01
In this paper we have present data from pilot studies to estimate the impact on patient care of an intensive care unit display station. The data were collected during two separate one-month periods in 1992. We compared these two different periods in terms of the relative speeds with which images were first viewed by MICU physicians. First, we found that images for routine chest radiographs (CXRs) are viewed by a greater number of physicians and slightly sooner with the PACS display station operating in the MICU than when it is not. Thus, for routine exams, PACS provide the potential for shortening of time intervals between exam completions and image-based clinical actions. A second finding is that the use of the display station for viewing non-routine CXRs is strongly influenced by the speed with which films are digitized. Hence, if film digitization is not rapid, the presence of a MICU display station is unlikely to contribute to a shortening of time intervals between exam completions and image-based clinical actions. This finding supports the use of computed radiography for CXRs in an intensive care unit.
Steerable dyadic wavelet transform and interval wavelets for enhancement of digital mammography
NASA Astrophysics Data System (ADS)
Laine, Andrew F.; Koren, Iztok; Yang, Wuhai; Taylor, Fred J.
1995-04-01
This paper describes two approaches for accomplishing interactive feature analysis by overcomplete multiresolution representations. We show quantitatively that transform coefficients, modified by an adaptive non-linear operator, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. Our results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. We design a filter bank representing a steerable dyadic wavelet transform that can be used for multiresolution analysis along arbitrary orientations. Digital mammograms are enhanced by orientation analysis performed by a steerable dyadic wavelet transform. Arbitrary regions of interest (ROI) are enhanced by Deslauriers-Dubuc interpolation representations on an interval. We demonstrate that our methods can provide radiologists with an interactive capability to support localized processing of selected (suspicion) areas (lesions). Features extracted from multiscale representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology can improve changes of early detection while requiring less time to evaluate mammograms for most patients.
NASA Astrophysics Data System (ADS)
Buckman, S. M.; Ius, D.
1996-02-01
This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.
Double-pulse digital speckle pattern interferometry for vibration analysis
NASA Astrophysics Data System (ADS)
Zhang, Dazhi; Xue, Jingfeng; Chen, Lu; Wen, Juying; Wang, Jingjing
2014-12-01
The double-pulse Digital Speckle Pattern Interferometry (DSPI) in the laboratory is established. Two good performances have been achieved at the same time, which is uniform distribution of laser beam energy by space filter and recording two successive pictures by a CCD camera successfully. Then two-dimensional discrete orthogonal wavelet transform method is used for the process of filtering method. By using the DSPI, speckle pattern of a vibrated object is obtained with interval of (2~800)μs, and 3D plot of the transient vibration is achieved. Moreover, good agreements of the mode shapes and displacement are obtained by comparing with Laser Doppler Vibrometer (LDV) .
Determination of heart rate variability with an electronic stethoscope.
Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M
2013-02-01
Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.
Digital Correlation In Laser-Speckle Velocimetry
NASA Technical Reports Server (NTRS)
Gilbert, John A.; Mathys, Donald R.
1992-01-01
Periodic recording helps to eliminate spurious results. Improved digital-correlation process extracts velocity field of two-dimensional flow from laser-speckle images of seed particles distributed sparsely in flow. Method which involves digital correlation of images recorded at unequal intervals, completely automated and has potential to be fastest yet.
NASA Astrophysics Data System (ADS)
Takeuchi, Eric B.; Flint, Graham W.; Bergstedt, Robert; Solone, Paul J.; Lee, Dicky; Moulton, Peter F.
2001-03-01
Electronic cinema projectors are being developed that use a digital micromirror device (DMDTM) to produce the image. Photera Technologies has developed a new architecture that produces truly digital imagery using discrete pulse trains of red, green, and blue light in combination with a DMDTM where in the number of pulses that are delivered to the screen during a given frame can be defined in a purely digital fashion. To achieve this, a pulsed RGB laser technology pioneered by Q-Peak is combined with a novel projection architecture that we refer to as Laser Digital CameraTM. This architecture provides imagery wherein, during the time interval of each frame, individual pixels on the screen receive between zero and 255 discrete pulses of each color; a circumstance which yields 24-bit color. Greater color depth, or increased frame rate is achievable by increasing the pulse rate of the laser. Additionally, in the context of multi-screen theaters, a similar architecture permits our synchronously pulsed RGB source to simultaneously power three screens in a color sequential manner; thereby providing an efficient use of photons, together with the simplifications which derive from using a single DMDTM chip in each projector.
Computer-assisted recording of tensile tests for the evaluation of serrated flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinhandl, H.; Mitter, F.; Bernt, W.
1994-12-01
In a previous paper the authors pointed out the difficulties which arise in the evaluation of serrated flow curves when the applied tensile strain rates are just above normal''. The recording system of tensile testing machines which were built, say, twenty years ago, are not capable of recording the full size of the load drops due to the inertia of the recording pen. This handicap was then overcome by establishing correction factors which were determined from recording a small number of load drops with an oscilloscope. Modern testing machines are equipped with digital recording. The disadvantage of the common systemmore » is, however, their limited capacity, so that not enough space for data points is available. Consequently, the time intervals between data points are of the order of tenths of seconds. It will become obvious from the present results that such a time interval is too large for recording a correct serration size. This report is concerned with the recording of complete load-extension relations during tensile tests using a computer which is capable of storing the data at sufficiently small time intervals.« less
Brunetti, Riccardo; Del Gatto, Claudia; Cavallina, Clarissa; Farina, Benedetto; Delogu, Franco
2018-05-01
The Corsi Block Tapping Task is a widespread test used to assess spatial working memory. Previous research hypothesized that the discrepancy found in some cases between the traditional and the digital (touchscreen) version of the Corsi block tapping task may be due to a direct motor resonance between the experimenter's and the participant's hand movements. However, we hypothesize that this discrepancy might be due to extra movement-related information included in the traditional version, lacking in the digital one. We investigated the effects of such task-irrelevant information using eCorsi, a touchscreen version of the task. In Experiment 1, we manipulate timing in sequence presentation, creating three conditions. In the Congruent condition, the inter-stimulus intervals reflected the physical distance in which the stimuli were spatially placed: The longer the spatial distance, the longer the temporal interval. In the Incongruent condition the timing changed randomly. Finally, in the Isochronous condition every stimulus appeared after a fixed interval, independently from its spatial position. The results showed a performance enhancement in the Congruent condition, suggesting an incidental spatio-temporal binding. In Experiment 2, we added straight lines between each location in the sequences: In the Trajectories condition participants saw trajectories from one spatial position to the other during sequence presentation, while a condition without such trajectories served as control. Results showed better performances in the Trajectories condition. We suggest that the timing and trajectories information play a significant role in the discrepancies found between the traditional and the touchscreen version of the Corsi Block Tapping Task, without the necessity of explanations involving direct motor resonance (e.g. seeing an actual hand moving) as a causal factor.
Picosecond Resolution Time-to-Digital Converter Using Gm-C Integrator and SAR-ADC
NASA Astrophysics Data System (ADS)
Xu, Zule; Miyahara, Masaya; Matsuzawa, Akira
2014-04-01
A picosecond resolution time-to-digital converter (TDC) is presented. The resolution of a conventional delay chain TDC is limited by the delay of a logic buffer. Various types of recent TDCs are successful in breaking this limitation, but they require a significant calibration effort to achieve picosecond resolution with a sufficient linear range. To address these issues, we propose a simple method to break the resolution limitation without any calibration: a Gm-C integrator followed by a successive approximation register analog-to-digital converter (SAR-ADC). This translates the time interval into charge, and then the charge is quantized. A prototype chip was fabricated in 90 nm CMOS. The measurement results reveal a 1 ps resolution, a -0.6/0.7 LSB differential nonlinearity (DNL), a -1.1/2.3 LSB integral nonlinearity (INL), and a 9-bit range. The measured 11.74 ps single-shot precision is caused by the noise of the integrator. We analyze the noise of the integrator and propose an improved front-end circuit to reduce this noise. The proposal is verified by simulations showing the maximum single-shot precision is less than 1 ps. The proposed front-end circuit can also diminish the mismatch effects.
Users manual for flight control design programs
NASA Technical Reports Server (NTRS)
Nalbandian, J. Y.
1975-01-01
Computer programs for the design of analog and digital flight control systems are documented. The program DIGADAPT uses linear-quadratic-gaussian synthesis algorithms in the design of command response controllers and state estimators, and it applies covariance propagation analysis to the selection of sampling intervals for digital systems. Program SCHED executes correlation and regression analyses for the development of gain and trim schedules to be used in open-loop explicit-adaptive control laws. A linear-time-varying simulation of aircraft motions is provided by the program TVHIS, which includes guidance and control logic, as well as models for control actuator dynamics. The programs are coded in FORTRAN and are compiled and executed on both IBM and CDC computers.
NASA Astrophysics Data System (ADS)
Lynch, John T.
1987-02-01
The present technique for coping with fading and burst noise on HF channels used in digital voice communications transmits digital voice only during high S/N time intervals, and speeds up the speech when necessary to avoid conversation-hindering delays. On the basis of informal listening tests, four test conditions were selected in order to characterize those conditions of speech interruption which would render it comprehensible or incomprehensible. One of the test conditions, 2 secs on and 1/2-sec off, yielded test scores comparable to the reference continuous speech case and is a reasonable match to the temporal variations of a disturbed ionosphere.
Li, Huaqing; Chen, Guo; Huang, Tingwen; Dong, Zhaoyang; Zhu, Wei; Gao, Lan
2016-12-01
In this paper, we consider the event-triggered distributed average-consensus of discrete-time first-order multiagent systems with limited communication data rate and general directed network topology. In the framework of digital communication network, each agent has a real-valued state but can only exchange finite-bit binary symbolic data sequence with its neighborhood agents at each time step due to the digital communication channels with energy constraints. Novel event-triggered dynamic encoder and decoder for each agent are designed, based on which a distributed control algorithm is proposed. A scheme that selects the number of channel quantization level (number of bits) at each time step is developed, under which all the quantizers in the network are never saturated. The convergence rate of consensus is explicitly characterized, which is related to the scale of network, the maximum degree of nodes, the network structure, the scaling function, the quantization interval, the initial states of agents, the control gain and the event gain. It is also found that under the designed event-triggered protocol, by selecting suitable parameters, for any directed digital network containing a spanning tree, the distributed average consensus can be always achieved with an exponential convergence rate based on merely one bit information exchange between each pair of adjacent agents at each time step. Two simulation examples are provided to illustrate the feasibility of presented protocol and the correctness of the theoretical results.
LED instrument approach instruction display
NASA Technical Reports Server (NTRS)
Meredith, B. D.; Kelly, W. L., IV; Crouch, R. K.
1979-01-01
A display employing light emitting diodes (LED's) was developed to demonstrate the feasibility of such displays for presenting landing and navigation information to reduce the workload of general aviation pilots during IFR flight. The display consists of a paper tape reader, digital memory, control electronics, digital latches, and LED alphanumeric displays. A presentable digital countdown clock-timer is included as part of the system to provide a convenient means of monitoring time intervals for precise flight navigation. The system is a limited capability prototype assembled to test pilot reaction to such a device under simulated IFR operation. Pilot opinion indicates that the display is helpful in reducing the IFR pilots workload when used with a runway approach plate. However, the development of a compact, low power second generation display was recommended which could present several instructions simultaneously and provide information update capability. A microprocessor-based display could fulfill these requirements.
Digital implementation of the TF30-P-3 turbofan engine control
NASA Technical Reports Server (NTRS)
Cwynar, D. S.; Batterton, P. G.
1975-01-01
The standard hydromechanical control modes for TF30-P-3 engine were implemented on a digital process control computer. Programming methods are described, and a method is presented to solve stability problems associated with fast response dynamic loops contained within the exhaust nozzle control. A modification of the exhaust nozzle control to provide for either velocity or position servoactuation systems is discussed. Transient response of the digital control was evaluated by tests on a real time hybrid simulation of the TF30-P-3 engine. It is shown that the deadtime produced by the calculation time delay between sampling and final output is more significant to transient response than the effects associated with sampling rate alone. For the main fuel control, extended update and calculation times resulted in a lengthened transient response to throttle bursts from idle to intermediate with an increase in high pressure compressor stall margin. Extremely long update intervals of 250 msec could be achieved without instability. Update extension for the exhaust nozzle control resulted in a delayed response of the afterburner light-off detector and exhaust nozzle overshoot with resulting fan oversuppression. Long update times of 150 msec caused failure of the control due to a false indication by the blowout detector.
Implementation of a high precision multi-measurement time-to-digital convertor on a Kintex-7 FPGA
NASA Astrophysics Data System (ADS)
Kuang, Jie; Wang, Yonggang; Cao, Qiang; Liu, Chong
2018-05-01
Time-to-digital convertors (TDCs) based on field programmable gate array (FPGA) are becoming more and more popular. Multi-measurement is an effective method to improve TDC precision beyond the cell delay limitation. However, the implementation of TDC with multi-measurement on FPGAs manufactured with 28 nm and more advanced process is facing new challenges. Benefiting from the ones-counter encoding scheme, which was developed in our previous work, we implement a ring oscillator multi-measurement TDC on a Xilinx Kintex-7 FPGA. Using the two TDC channels to measure time-intervals in the range (0 ns-30 ns), the average RMS precision can be improved to 5.76 ps, meanwhile the logic resource usage remains the same with the one-measurement TDC, and the TDC dead time is only 22 ns. The investigation demonstrates that the multi-measurement methods are still available for current main-stream FPGAs. Furthermore, the new implementation in this paper could make the trade-off among the time precision, resource usage and TDC dead time better than ever before.
Real-time multiplicity counter
Rowland, Mark S [Alamo, CA; Alvarez, Raymond A [Berkeley, CA
2010-07-13
A neutron multi-detector array feeds pulses in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel. The word is read at regular intervals, all bits simultaneously, to minimize latency. The electronics then pass the word to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup.
Vandenberghe, Bart; Corpas, Livia; Bosmans, Hilde; Yang, Jie; Jacobs, Reinhilde
2011-08-01
The aim of this study was the determination of image accuracy and quality for periodontal diagnosis using various X-ray generators with conventional and digital radiographs. Thirty-one in vitro periodontal defects were evaluated on intraoral conventional (E-, F/E-speed) and digital images (three indirect, two direct sensors). Standardised radiographs were made with an alternating current (AC), a high-frequency (HF) and a direct current (DC) X-ray unit at rising exposure times (20-160 ms with 20-ms interval) with a constant kV of 70. Three observers assessed bone levels for comparison to the gold standard. Lamina dura, contrast, trabecularisation, crater and furcation involvements were evaluated. Irrespective X-ray generator-type, measurement deviations increased at higher exposure times for solid-state, but decreased for photostimulable storage phosphor (PSP) systems. Accuracy for HF or DC was significantly higher than AC (p < 0.0001), especially at low exposure times. At 0.5- to 1-mm clinical deviation, 27-53% and 32-55% dose savings were demonstrated when using HF or DC generators compared to AC, but only for PSP. No savings were found for solid-state sensors, indicating their higher sensitivity. The use of digital sensors compared to film allowed 15-90% dose savings using the AC tube, whilst solid-state sensors allowed approximately 50% savings compared to PSP, depending on tube type and threshold level.. Accuracy of periodontal diagnosis increases when using HF or DC generators and/or digital receptors with adequate diagnostic information at lower exposure times.
1993-12-02
electronics. In other words, while the main driving force of the past has been the desire for greater performance by way of accuracy, the future will demand ...that can match him in terms of number of years in the program; but there are a lot of folks that are brand new to the program. What is precise time...International Telecommunications Union (ITU). The additional development of a digital-filter view of all of these two-sample variances113) has
Real-time control systems: feedback, scheduling and robustness
NASA Astrophysics Data System (ADS)
Simon, Daniel; Seuret, Alexandre; Sename, Olivier
2017-08-01
The efficient control of real-time distributed systems, where continuous components are governed through digital devices and communication networks, needs a careful examination of the constraints arising from the different involved domains inside co-design approaches. Thanks to the robustness of feedback control, both new control methodologies and slackened real-time scheduling schemes are proposed beyond the frontiers between these traditionally separated fields. A methodology to design robust aperiodic controllers is provided, where the sampling interval is considered as a control variable of the system. Promising experimental results are provided to show the feasibility and robustness of the approach.
Improving education: just-in-time splinting video.
Wang, Vincent; Cheng, Yu-Tsun; Liu, Deborah
2016-06-01
Just-in-time training (JITT) is an emerging concept in medical procedural education, but with few studies to support its routine use. Providing a brief educational intervention in the form of a digital video immediately prior to patient care may be an effective method to reteach knowledge for procedural techniques learned previously. Paediatric resident physicians were taught to perform a volar splint in a small workshop setting. Subsequently, they were asked to demonstrate their splinting proficiency by performing a splint on another doctor. Proficiency was scored on a five-point assessment tool. After 2-12 months, participants were asked to demonstrate their splinting proficiency on one of the investigators, and were divided into the control group (no further instruction) and the intervention group, which viewed a 3-minute JITT digital video demonstrating the splinting technique prior to performing the procedure. Thirty subjects were enrolled between August 2012 and July 2013, and 29 of 30 completed the study. The retest splinting time was not significantly different, but if the JITT group included watching the video, the total time difference was statistically significant: 3.86 minutes (control) versus 7.07 minutes (JITT) (95% confidence interval: 2.20-3.90 minutes). The average assessment score difference was 1.87 points higher for the JITT group, which was a statistically significant difference (95% confidence interval: 1.00-3.00). Just-in-time training is an emerging concept in medical procedural education JITT seems to be an effective tool in medical education for reinforcing previously learned skills. JITT may offer other possibilities for enhancing medical education. © 2015 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Kole, James A.; Schneider, Vivian I.; Healy, Alice F.; Barshi, Immanuel
2017-01-01
Subjects trained in a standard data entry task, which involved typing numbers (e.g., 5421) using their right hands. At test (6 months post-training), subjects completed the standard task, followed by a left-hand variant (typing with their left hands) that involved the same perceptual, but different motoric, processes as the standard task. At a second test (8 months post-training), subjects completed the standard task, followed by a code variant (translating letters into digits, then typing the digits with their right hands) that involved different perceptual, but the same motoric, processes as the standard task. For each of the three tasks, half the trials were trained numbers (old) and half were new. Repetition priming (faster response times to old than new numbers) was found for each task. Repetition priming for the standard task reflects retention of trained numbers; for the left-hand variant reflects transfer of perceptual processes; and for the code variant reflects transfer of motoric processes. There was thus evidence for both specificity and generalizability of training data entry perceptual and motoric processes over very long retention intervals.
A text zero-watermarking method based on keyword dense interval
NASA Astrophysics Data System (ADS)
Yang, Fan; Zhu, Yuesheng; Jiang, Yifeng; Qing, Yin
2017-07-01
Digital watermarking has been recognized as a useful technology for the copyright protection and authentication of digital information. However, rarely did the former methods focus on the key content of digital carrier. The idea based on the protection of key content is more targeted and can be considered in different digital information, including text, image and video. In this paper, we use text as research object and a text zero-watermarking method which uses keyword dense interval (KDI) as the key content is proposed. First, we construct zero-watermarking model by introducing the concept of KDI and giving the method of KDI extraction. Second, we design detection model which includes secondary generation of zero-watermark and the similarity computing method of keyword distribution. Besides, experiments are carried out, and the results show that the proposed method gives better performance than other available methods especially in the attacks of sentence transformation and synonyms substitution.
Adler, D; Mahler, Y
1980-04-01
A procedure for automatic detection and digital processing of the maximum first derivative of the intraventricular pressure (dp/dtmax), time to dp/dtmax(t - dp/dt) and beat-to-beat intervals have been developed. The procedure integrates simple electronic circuits with a short program using a simple algorithm for the detection of the points of interest. The tasks of differentiating the pressure signal and detecting the onset of contraction were done by electronics, while the tasks of finding the values of dp/dtmax, t - dp/dt, beat-to-beat intervals and all computations needed were done by software. Software/hardware 'trade off' considerations and the accuracy and reliability of the system are discussed.
A computer system for analysis and transmission of spirometry waveforms using volume sampling.
Ostler, D V; Gardner, R M; Crapo, R O
1984-06-01
A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.
The Scientific Legacy of Charles Wheatstone
NASA Astrophysics Data System (ADS)
Greenslade, Thomas B.
2017-02-01
Charles Wheatstone's name was once familiar to students because they used his eponymous bridge to measure resistances. That usage seems to be disappearing—we all have access to digital ohmmeters—but the techniques that he developed for making electrical measurements can still be used with profit. Also, his work with measuring very short time intervals and his work with musical acoustics are still with us, if in modified forms. Here are a few examples of his work.
Robust and intelligent bearing estimation
Claassen, John P.
2000-01-01
A method of bearing estimation comprising quadrature digital filtering of event observations, constructing a plurality of observation matrices each centered on a time-frequency interval, determining for each observation matrix a parameter such as degree of polarization, linearity of particle motion, degree of dyadicy, or signal-to-noise ratio, choosing observation matrices most likely to produce a set of best available bearing estimates, and estimating a bearing for each observation matrix of the chosen set.
Virtual Sensors in a Web 2.0 Digital Watershed
NASA Astrophysics Data System (ADS)
Liu, Y.; Hill, D. J.; Marini, L.; Kooper, R.; Rodriguez, A.; Myers, J. D.
2008-12-01
The lack of rainfall data in many watersheds is one of the major barriers for modeling and studying many environmental and hydrological processes and supporting decision making. There are just not enough rain gages on the ground. To overcome this data scarcity issue, a Web 2.0 digital watershed is developed at NCSA(National Center for Supercomputing Applications), where users can point-and-click on a web-based google map interface and create new precipitation virtual sensors at any location within the same coverage region as a NEXRAD station. A set of scientific workflows are implemented to perform spatial, temporal and thematic transformations to the near-real-time NEXRAD Level II data. Such workflows can be triggered by the users' actions and generate either rainfall rate or rainfall accumulation streaming data at a user-specified time interval. We will discuss some underlying components of this digital watershed, which consists of a semantic content management middleware, a semantically enhanced streaming data toolkit, virtual sensor management functionality, and RESTful (REpresentational State Transfer) web service that can trigger the workflow execution. Such loosely coupled architecture presents a generic framework for constructing a Web 2.0 style digital watershed. An implementation of this architecture at the Upper Illinois Rive Basin will be presented. We will also discuss the implications of the virtual sensor concept for the broad environmental observatory community and how such concept will help us move towards a participatory digital watershed.
Gopalan, Reji P; Nair, Vivek V; Harshakumar, K; Ravichandran, R; Lylajam, S; Viswambaran, Prasanth
2018-01-01
Different pattern materials do not produce copings with satisfactory, marginal accuracy when used on stone dies at varying time intervals. The purpose of this study was to evaluate and compare the vertical marginal accuracy of patterns formed from three materials, namely, thermoplastic resin, light cured wax and inlay casting wax at three-time intervals of 1, 12, and 24 h. A master die (zirconia abutment mimicking a prepared permanent maxillary central incisor) and metal sleeve (direct metal laser sintering crown #11) were fabricated. A total of 30 stone dies were obtained from the master die. Ten patterns were made each from the three materials and stored off the die at room temperature. The vertical marginal gaps were measured using digital microscope at 1, 12, and 24 h after reseating with gentle finger pressure. The results revealed a significant statistical difference in the marginal adaptation of three materials at all the three-time intervals. Light cured wax was found to be most accurate at all time intervals, followed by thermoplastic resin and inlay casting wax. Furthermore, there was a significant difference between all pairs of materials. The change in vertical marginal gap from 1 to 24 h between thermoplastic resin and light cured wax was not statistically significant. The marginal adaptation of all the three materials used, was well within the acceptable range of 25-70 μm. The resin pattern materials studied revealed significantly less dimensional change than inlay casting wax on storage at 1, 12, and 24 h time intervals. They may be employed in situations where high precision and delayed investing is expected.
Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin
2016-01-01
Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken. PMID:27226958
Efficacy of a Single Dose of Basic Fibroblast Growth Factor: Clinical Observation for 1 Year.
Suzuki, Hirotaka; Makiyama, Kiyoshi; Hirai, Ryoji; Matsuzaki, Hiroumi; Furusaka, Toru; Oshima, Takeshi
2016-11-01
Basic fibroblast growth factor promotes wound healing by accelerating healthy granulation and epithelialization. However, the duration of the effects of a single intracordal injection of basic fibroblast growth factor has not been established, and administration intervals and timing have yet to be standardized. Here, we administered a single injection to patients with insufficient glottic closure and conducted follow-up examinations with high-speed digital imaging to determine the duration of the treatment response. Case series. For treatment, 20 µg/mL recombinant human basic fibroblast growth factor was injected into two vocal cords. The following examinations were performed before the procedure and at 3-month intervals for 12 months starting at 1 month postinjection: Grade, Roughness, Breathiness, Asthenia, and Strain (GRBAS) scale assessment, maximum phonation time, acoustic analysis, high-speed digital imaging, glottal wave analysis, and kymographic analysis. Postinjection, the GRBAS scale score decreased, and the maximum phonation time was prolonged. In addition, the mean minimum glottal area and mean minimum glottal distance decreased. These changes were significant at 12 months postinjection compared with preinjection. However, there were no significant changes in the vibrations of the vocal cord margins. The intracordal injection of basic fibroblast growth factor improved insufficient glottic closure without reducing the vibrations of the vocal cord margins. This effect remained evident at 12 months postinjection. A single injection can be expected to yield a sufficient and persistent long-term effect. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Sanford, Jordan M.; Harrison, Arnell S.; Wiese, Dana S.; Flocks, James G.
2008-01-01
In June and August of 1992, the U.S. Geological Survey (USGS) conducted geophysical surveys to investigate the shallow geologic framework from Lake Pontchartrain, Louisiana, to Mobile Bay, Alabama. This work was conducted onboard the Argonne National Laboratory's R/V ERDA-1 as part of the Mississippi/Alabama Pollution Project. This report is part of a series to digitally archive the legacy analog data collected from the Mississippi-Alabama SHelf (MASH). The MASH data rescue project is a cooperative effort by the USGS and the Minerals Management Service (MMS). A standardized naming convention was established to allow for better management of scanned trackline images within the MASH data rescue project. Each cruise received a unique field activity ID based on the year the data were collected, the first two digits of the survey vessel name, and the number of cruises made (to date) by that vessel that year (i.e. 92ER2 represents the second cruise made by the R/V ERDA-1 in 1992.) The new field activity IDs 92ER2 and 92ER4 presented in this report were originally referred to as ERDA 92-2 and ERDA 92-4 at the USGS in St. Petersburg, FL, and 92010 and 92037 at the USGS in Woods Hole, MA. A table showing the naming convention lineage for cruise IDs in the MASH data rescue series is included as a PDF. This report serves as an archive of high resolution scanned Tagged Image File Format (TIFF) and Graphics Interchange Format (GIF) images of the original boomer paper records, navigation files, trackline maps, Geographic Information System (GIS) files, cruise logs, and formal Federal Geographic Data Committee (FGDC) metadata for cruises 92ER2 and 92ER4. The boomer system uses an acoustic energy source called a plate, which consists of capacitors charged to a high voltage and discharged through a transducer in the water. The source is towed on a sled, at sea level, and when discharged emits a short acoustic pulse, or shot, which propagates through the water and sediment column. The acoustic energy is reflected at density boundaries (such as the seafloor or sediment layers beneath the seafloor), detected by the hydrophone receiver, and the amplitude of the reflected energy is recorded by an Edward P. Curley Lab (EPC) thermal plotter. This process is repeated at timed intervals (for example, 0.5 s) and recorded for specific intervals of time (for example, 100 ms). The timed intervals are also referred to as the shot interval or fire rate. On analog records, the recorded interval is referred to as the sweep, which is the amount of time the recorder stylus takes to sweep from the top of the record to the bottom of the record, thereby recording the amplitude of the reflected energy of one shot. In this way, consecutive recorded shots produce a two-dimensional (2-D) vertical image of the shallow geologic structure beneath the ship track. Many of the geophysical data collected by the USGS prior to the late 1990s were recorded in analog format and stored as paper copies. Scientists onboard made hand-written annotations onto these records to note latitude and longitude, time, line number, course heading, and geographic points of reference. Each paper roll typically contained numerous survey lines and could reach more than 90 ft in length. All rolls are stored at the USGS FISC-St. Petersburg, FL. To preserve the integrity of these records and improve accessibility, analog holdings were converted to digital files.
Canine digital tumors: a veterinary cooperative oncology group retrospective study of 64 dogs.
Henry, Carolyn J; Brewer, William G; Whitley, Elizabeth M; Tyler, Jeff W; Ogilvie, Gregory K; Norris, Alan; Fox, Leslie E; Morrison, Wallace B; Hammer, Alan; Vail, David M; Berg, John
2005-01-01
We compared clinical characteristics and outcomes for dogs with various digital tumors. Medical records and histology specimens of affected dogs from 9 veterinary institutions were reviewed. Risk factors examined included age, weight, sex, tumor site (hindlimb or forelimb), local tumor (T) stage, metastases, tumor type, and treatment modality. The Kaplan-Meier product limit method was used to determine the effect of postulated risk factors on local disease-free interval (LDFI), metastasis-free interval (MFI), and survival time (ST). Outcomes were thought to differ significantly between groups when P < or = .003. Sixty-four dogs were included. Squamous cell carcinoma (SCC) accounted for 33 (51.6%) of the tumors. Three dogs presented with or developed multiple digital SCC. Other diagnoses included malignant melanoma (MM) (n = 10; 15.6%), osteosarcoma (OSA) (n = 4; 6.3%), hemangiopericytoma (n = 3; 4.7%), benign soft tissue tumors (n = 5; 7.8%), and malignant soft tissue tumors (n = 9; 14%). Fourteen dogs with malignancies had black hair coats, including 5 of the 10 dogs with MM. Surgery was the most common treatment and, regardless of the procedure, had a positive impact on survival. None of the patient variables assessed, including age, sex, tumor type, site, and stage, had a significant impact on ST. Both LDFI and MFI were negatively affected by higher T stage, but not by type of malignancy. Although metastasis at diagnosis correlated with a shorter LDFI, it did not have a significant impact on ST. On the basis of these findings, early surgical intervention is advised for the treatment of dogs with digital tumors, regardless of tumor type or the presence of metastatic disease.
High-rate dead-time corrections in a general purpose digital pulse processing system
Abbene, Leonardo; Gerardi, Gaetano
2015-01-01
Dead-time losses are well recognized and studied drawbacks in counting and spectroscopic systems. In this work the abilities on dead-time correction of a real-time digital pulse processing (DPP) system for high-rate high-resolution radiation measurements are presented. The DPP system, through a fast and slow analysis of the output waveform from radiation detectors, is able to perform multi-parameter analysis (arrival time, pulse width, pulse height, pulse shape, etc.) at high input counting rates (ICRs), allowing accurate counting loss corrections even for variable or transient radiations. The fast analysis is used to obtain both the ICR and energy spectra with high throughput, while the slow analysis is used to obtain high-resolution energy spectra. A complete characterization of the counting capabilities, through both theoretical and experimental approaches, was performed. The dead-time modeling, the throughput curves, the experimental time-interval distributions (TIDs) and the counting uncertainty of the recorded events of both the fast and the slow channels, measured with a planar CdTe (cadmium telluride) detector, will be presented. The throughput formula of a series of two types of dead-times is also derived. The results of dead-time corrections, performed through different methods, will be reported and discussed, pointing out the error on ICR estimation and the simplicity of the procedure. Accurate ICR estimations (nonlinearity < 0.5%) were performed by using the time widths and the TIDs (using 10 ns time bin width) of the detected pulses up to 2.2 Mcps. The digital system allows, after a simple parameter setting, different and sophisticated procedures for dead-time correction, traditionally implemented in complex/dedicated systems and time-consuming set-ups. PMID:26289270
NASA Astrophysics Data System (ADS)
Song, Z.; Wang, Y.; Kuang, J.
2018-05-01
Field Programmable Gate Arrays (FPGAs) made with 28 nm and more advanced process technology have great potentials for implementation of high precision time-to-digital convertors (TDC), because the delay cells in the tapped delay line (TDL) used for time interpolation are getting smaller and smaller. However, the bubble problems in the TDL status are becoming more complicated, which make it difficult to achieve TDCs on these chips with a high time precision. In this paper, we are proposing a novel decomposition encoding scheme, which not only can solve the bubble problem easily, but also has a high encoding efficiency. The potential of these chips to realize TDC can be fully released with the scheme. In a Xilinx Kintex-7 FPGA chip, we implemented a TDC system with 256 TDC channels, which doubles the number of TDC channels that our previous technique could achieve. Performances of all these TDC channels are evaluated. The average RMS time precision among them is 10.23 ps in the time-interval measurement range of (0–10 ns), and their measurement throughput reaches 277 M measures per second.
Programmable noise bandwidth reduction by means of digital averaging
NASA Technical Reports Server (NTRS)
Poklemba, John J. (Inventor)
1993-01-01
Predetection noise bandwidth reduction is effected by a pre-averager capable of digitally averaging the samples of an input data signal over two or more symbols, the averaging interval being defined by the input sampling rate divided by the output sampling rate. As the averaged sample is clocked to a suitable detector at a much slower rate than the input signal sampling rate the noise bandwidth at the input to the detector is reduced, the input to the detector having an improved signal to noise ratio as a result of the averaging process, and the rate at which such subsequent processing must operate is correspondingly reduced. The pre-averager forms a data filter having an output sampling rate of one sample per symbol of received data. More specifically, selected ones of a plurality of samples accumulated over two or more symbol intervals are output in response to clock signals at a rate of one sample per symbol interval. The pre-averager includes circuitry for weighting digitized signal samples using stored finite impulse response (FIR) filter coefficients. A method according to the present invention is also disclosed.
Petretta, Robert; Strelzow, Jason; Ohly, Nicholas E; Misur, Peter; Masri, Bassam A
2015-12-01
Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. Level III, diagnostic study.
Ripamonti, Giancarlo; Abba, Andrea; Geraci, Angelo
2010-05-01
A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.
High-Speed Observer: Automated Streak Detection in SSME Plumes
NASA Technical Reports Server (NTRS)
Rieckoff, T. J.; Covan, M.; OFarrell, J. M.
2001-01-01
A high frame rate digital video camera installed on test stands at Stennis Space Center has been used to capture images of Space Shuttle main engine plumes during test. These plume images are processed in real time to detect and differentiate anomalous plume events occurring during a time interval on the order of 5 msec. Such speed yields near instantaneous availability of information concerning the state of the hardware. This information can be monitored by the test conductor or by other computer systems, such as the integrated health monitoring system processors, for possible test shutdown before occurrence of a catastrophic engine failure.
Time-dependent seismic tomography of the Coso geothermal area, 1996-2004
Julian, B.R.; Foulger, G.R.
2005-01-01
The permanent 18-station network of three-component digital seismometers at the seismically active Coso geothermal area, California, provides high-quality microearthquake (MEQ) data that are well suited to investigating temporal variations in structure related to processes within the geothermal reservoir. A preliminary study [Julian, et al., 2003; Julian, et al., 2004] comparing data from 1996 and 2003 found significant variations in the ratio of the seismic wave-speeds, Vp/Vs, at shallow depths over this time interval. This report describes results of a more detailed study of each year from 1996 through 2004.
Malvasi, Antonio; Stark, Michael; Ghi, Tullio; Farine, Dan; Guido, Marcello; Tinelli, Andrea
2012-05-01
The primary goal of this study was to determine the ultrasonographic signs of asynclitic and transverse head positioning. In addition, we compared the performance of intrapartum ultrasound to vaginal digital examination. 150 women were evaluated by 2D transabdominal and translabial ultrasound (US) to detect the asynclitic and deep transverse positions. Transvaginal sterile digital examinations were performed immediately after each intrapartum US assessments, the examinations were repeated at intervals of 45-90 minutes. Examiners were blinded to each other's findings (clinical or sonographic). Data were reviewed and analyzed by an independent reviewer. The efficacy of digital examination was significantly lower than US evaluation for the detection of either transverse position or asynclitism. The most frequent transverse position was the left one, while the most frequent asynclitism was the anterior one. Digital pelvic examination for detection of fetal head transverse position during labor is inferior to US, especially in the deep transverse positioning, where caput succedaneum occurs and reduces the diagnostic accuracy of vaginal digital examination. The US examination leads to early detection of persistent transverse position allowing for earlier timing and optimal technique for the operative vaginal delivery. We describe two signs for diagnosing asynclitism. The "squint sign" and the "sunset of thalamus and cerebellum signs" are two simple US signs allowing detection of anterior and posterior asynclitism.
Design of time interval generator based on hybrid counting method
NASA Astrophysics Data System (ADS)
Yao, Yuan; Wang, Zhaoqi; Lu, Houbing; Chen, Lian; Jin, Ge
2016-10-01
Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some "off-the-shelf" TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.
Fast energy spectrum and transverse beam profile monitoring and feedback systems for the SLC linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soderstrom, E.J.; Abrams, G.S.; Weinstein, A.J.
Fast energy spectrum and transverse beam profile monitoring systems have been tested at the SLC. The signals for each system are derived from digitizations of images on phosphor screens. Individual beam bunch images are digitized in the case of the transverse profile system and synchrotron radiation images produced by wiggler magnets for the energy spectrum. Measurements are taken at two-second intervals. Feedback elements have been installed for future use and consist of rf phase shifters to control energy spectrum and dipole correctors to control the beam launch into the linac affecting the transverse beam profile. Details of these systems, includingmore » hardware, timing, data acquisition, data reduction, measurement accuracy, and operational experience will be presented. 9 refs.« less
NASA Astrophysics Data System (ADS)
Díaz, L.; Morales, Y.; Torres, C.
2015-01-01
The esthetic dentistry reference in our society is determined by several factors, including one that produces more dissatisfaction is abnormal tooth color or that does not meet the patient's expectations. For this reason it has been designed and implemented an algorithm in MATLAB that captures, digitizes, pre-processing and analyzed dental imaging by allowing to evaluate the degree of bleaching caused by the use of peroxide of hidrogen. The samples analyzed were human teeth extracted, which were subjected to different concentrations of peroxide of hidrogen and see if they can teeth whitening when using these products, was used different concentrations and intervals of time to analysis or study of the whitening of the teeth with the hydrogen peroxide.
Rammsayer, Thomas H; Verner, Martin
2016-05-01
Perceived duration has been shown to be positively related to task-irrelevant, nontemporal stimulus magnitude. To account for this finding, Walsh's (2003) A Theory of Magnitude (ATOM) model suggests that magnitude of time is not differentiated from magnitude of other nontemporal stimulus characteristics and collectively processed by a generalized magnitude system. In Experiment 1, we investigated the combined effects of stimulus size and numerical quantity, as two nontemporal stimulus dimensions covered by the ATOM model, on duration judgments. Participants were required to reproduce the duration of target intervals marked by Arabic digits varying in physical size and numerical value. While the effect of stimulus size was effectively moderated by target duration, the effect of numerical value appeared to require attentional resources directed to the numerical value in order to become effective. Experiment 2 was designed to further elucidate the mediating influence of attention on the effect of numerical value on duration judgments. An effect of numerical value was only observed when participants' attention was directed to digit value, but not when participants were required to pay special attention to digit parity. While the ATOM model implies a common metrics and generalized magnitude processing for time, size, and quantity, the present findings provided converging evidence for the notion of two qualitatively different mechanisms underlying the effects of nontemporal stimulus size and numerical value on duration judgments. Furthermore, our data challenge the implicit common assumption that the effect of numerical value on duration judgments represents a continuously increasing function of digit magnitude.
Knox, Mark; O'Brien, Angela; Szabó, Endre; Smith, Clare S; Fenlon, Helen M; McNicholas, Michelle M; Flanagan, Fidelma L
2015-06-01
Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p=.77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p=.02). Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ritchie, A.; Bountry, J.; Randle, T. J.; Warrick, J. A.
2016-12-01
The stepwise removal of two dams on the Elwha River beginning in September 2011 exposed 21 million cubic meters of sediment to fluvial erosion and created an unprecedented opportunity to monitor reservoir sediment erosion and river evolution during base level adjustment and a pulsed sediment release. We conduct repeat aerial surveys with a Cessna 172 using a simple custom wing-mount for consumer grade cameras and SfM photogrammetry to produce orthoimagery and digital elevation models in near-real-time at sub-weekly to monthly time intervals, depending on hydrology. Multiple lidar flights and ground survey campaigns provide estimates of both systematic and random error for this uniquely dense dataset. Co-registration of multiple SfM surveys during processing reduces systematic error and allows boot-strapping of ephemeral ground control points to earlier or later flights. Measurements of reservoir erosion volumes, delta growth, channel braiding, and bank erosion illustrate the reservoir and river channel responses to dam removal at resolutions comparable to hydrologic forcing events, allowing us to quantify reservoir sediment budgets on a per-storm basis. This allows for the analysis of sediment transported relative to rates of reservoir drawdown and river stream power for dozens of time intervals. Temporal decoupling of peak sediment flux and bank erosion rates is noted from these analyses. This dataset illustrates both challenges and opportunities emerging with the advent of big data in remote sensing of earth surface processes. Digital AbstractErosion and deposition by year in former Lake Mills reservoir measured using SfM-derived photogrammetry and LiDAR for WY2011 through 2016 (partial). Approximately 70% of available sediment has been eroded.
Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K
2018-06-01
Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018 Elsevier Inc. All rights reserved.
Effects of digital mammography uptake on downstream breast-related care among older women.
Hubbard, Rebecca A; Zhu, Weiwei; Onega, Tracy L; Fishman, Paul; Henderson, Louise M; Tosteson, Anna N A; Buist, Diana S M
2012-12-01
Digital mammography is the dominant modality for breast cancer screening in the United States. No previous studies have investigated as to how introducing digital mammography affects downstream breast-related care. Compare breast-related health care use after a screening mammogram before and after introduction of digital mammography. Longitudinal study of screening mammograms from 14 radiology facilities contributing data to the Breast Cancer Surveillance Consortium performed 1 year before and 4 years after each facility introduced digital mammography, along with linked Medicare claims. We included 30,211 mammograms for women aged 66 years and older without breast cancer. Rates of false-positive recall and short-interval follow-up were based on radiologists' assessments and recommendations; rates of follow-up mammography, ultrasound, and breast biopsy use were based on Medicare claims. False-positive recall rates increased after the introduction of digital mammography. Follow-up mammography use was significantly higher across all 4 years after a facility began using digital mammography compared with the year before [year 1 odds ratio (OR) = 1.7, 95% confidence interval (CI), 1.4-2.1]. Among women with false-positive mammography results, use of ultrasound decreased significantly in the second through fourth years after digital mammography began (year 2 OR = 0.4, 95% CI, 0.3-0.6). Introduction of a new technology led to changes in health care use that persisted for at least 4 years. Comparative effectiveness research on new technologies should consider not only diagnostic performance but also downstream utilization attributable to this apparent learning curve.
NASA Astrophysics Data System (ADS)
Papailiou, M.; Dimitrova, S.; Babayev, E. S.; Mavromichalaki, H.
2010-01-01
Collaborating scientific groups from Athens (Greece), Baku (Azerbaijan) and Sofia (Bulgaria) have conducted a research work on the possible effects of geomagnetic field disturbances (GMF) and cosmic ray intensity (CRI) variations on human homeostasis, particularly, the cardio-health state. Electrocardiograms (ECGs) of seven functionally healthy persons were digitally registered at the joint Laboratory of Heliobiology located in the Medical Centre INAM, Baku, on working days and Saturdays. Heart rate values, estimated from ECGs, were analysed in relation to daily values of CRI, as measured by the Neutron Monitor of the University of Athens and daily variations of Dst and Ap geomagnetic indices and some significant results had been revealed in previous studies. Researches were continued by study of additional cardiologic parameters estimated from the same ECG data. In this study digital data of RR interval (the time elapsing between two consecutive R waves in the ECG), namely RRminimum, RRmaximum and RRaverage were analyzed taking into consideration different levels of GMF disturbances (estimated through variations of Dst and Ap indices) and cosmic ray activity (through CRI variations). The data refer to the time period 15 July 2006-31 March 2008. Variations of RR intervals show connection to GMF disturbances and CRI variations. The revealed effects are more pronounced for high levels of geomagnetic activity (when geomagnetic storms occur) and large CRI decreases as well as on the days before and after these variations.
Alves, Christiano R R; Tessaro, Victor H; Teixeira, Luis A C; Murakava, Karina; Roschel, Hamilton; Gualano, Bruno; Takito, Monica Y
2014-02-01
Acute moderate intensity continuous aerobic exercise can improve specific cognitive functions, such as short-term memory and selective attention. Moreover, high-intensity interval training (HIT) has been recently proposed as a time-efficient alternative to traditional cardiorespiratory exercise. However, considering previous speculations that the exercise intensity affects cognition in a U-shaped fashion, it was hypothesized that a HIT session may impair cognitive performance. Therefore, this study assessed the effects of an acute HIT session on selective attention and short-term memory tasks. 22 healthy middle-aged individuals (M age = 53.7 yr.) engaged in both (1) a HIT session, 10 1 min. cycling bouts at the intensity corresponding to 80% of the reserve heart rate interspersed by 1 min. active pauses cycling at 60% of the reserve heart rate and (2) a control session, consisting of an active condition with low-intensity active stretching exercise. Before and after each experimental session, cognitive performance was assessed by the Victoria Version of the Stroop test (a selective attention test) and the Digit Span test (a short-term memory test). Following the HIT session, the time to complete the Stroop "Color word" test was significantly lower when compared with that of the control session. The performances in the other subtasks of the Stroop test as well as in the Digit Span test were not significantly different. A HIT session can improve cognitive function.
Infrared Sky Imager (IRSI) Instrument Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, Victor R.
2016-04-01
The Infrared Sky Imager (IRSI) deployed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility is a Solmirus Corp. All Sky Infrared Visible Analyzer. The IRSI is an automatic, continuously operating, digital imaging and software system designed to capture hemispheric sky images and provide time series retrievals of fractional sky cover during both the day and night. The instrument provides diurnal, radiometrically calibrated sky imagery in the mid-infrared atmospheric window and imagery in the visible wavelengths for cloud retrievals during daylight hours. The software automatically identifies cloudy and clear regions at user-defined intervals and calculates fractional sky cover, providing amore » real-time display of sky conditions.« less
Friedman, Matt; Brazeau, Martin D
2011-02-07
Past research on the emergence of digit-bearing tetrapods has led to the widely accepted premise that this important evolutionary event occurred during the Late Devonian. The discovery of convincing digit-bearing tetrapod trackways of early Middle Devonian age in Poland has upset this orthodoxy, indicating that current scenarios which link the timing of the origin of digited tetrapods to specific events in Earth history are likely to be in error. Inspired by this find, we examine the fossil record of early digit-bearing tetrapods and their closest fish-like relatives from a statistical standpoint. We find that the Polish trackways force a substantial reconsideration of the nature of the early tetrapod record when only body fossils are considered. However, the effect is less drastic (and often not statistically significant) when other reliably dated trackways that were previously considered anachronistic are taken into account. Using two approaches, we find that 95 per cent credible and confidence intervals for the origin of digit-bearing tetrapods extend into the Early Devonian and beyond, spanning late Emsian to mid Ludlow. For biologically realistic diversity models, estimated genus-level preservation rates for Devonian digited tetrapods and their relatives range from 0.025 to 0.073 per lineage-million years, an order of magnitude lower than species-level rates for groups typically considered to have dense records. Available fossils of early digited tetrapods and their immediate relatives are adequate for documenting large-scale patterns of character acquisition associated with the origin of terrestriality, but low preservation rates coupled with clear geographical and stratigraphic sampling biases caution against building scenarios for the origin of digits and terrestrialization tied to the provenance of particular specimens or faunas.
Novel method for high-throughput phenotyping of sleep in mice.
Pack, Allan I; Galante, Raymond J; Maislin, Greg; Cater, Jacqueline; Metaxas, Dimitris; Lu, Shan; Zhang, Lin; Von Smith, Randy; Kay, Timothy; Lian, Jie; Svenson, Karen; Peters, Luanne L
2007-01-17
Assessment of sleep in mice currently requires initial implantation of chronic electrodes for assessment of electroencephalogram (EEG) and electromyogram (EMG) followed by time to recover from surgery. Hence, it is not ideal for high-throughput screening. To address this deficiency, a method of assessment of sleep and wakefulness in mice has been developed based on assessment of activity/inactivity either by digital video analysis or by breaking infrared beams in the mouse cage. It is based on the algorithm that any episode of continuous inactivity of > or =40 s is predicted to be sleep. The method gives excellent agreement in C57BL/6J male mice with simultaneous assessment of sleep by EEG/EMG recording. The average agreement over 8,640 10-s epochs in 24 h is 92% (n = 7 mice) with agreement in individual mice being 88-94%. Average EEG/EMG determined sleep per 2-h interval across the day was 59.4 min. The estimated mean difference (bias) per 2-h interval between inactivity-defined sleep and EEG/EMG-defined sleep was only 1.0 min (95% confidence interval for mean bias -0.06 to +2.6 min). The standard deviation of differences (precision) was 7.5 min per 2-h interval with 95% limits of agreement ranging from -13.7 to +15.7 min. Although bias significantly varied by time of day (P = 0.0007), the magnitude of time-of-day differences was not large (average bias during lights on and lights off was +5.0 and -3.0 min per 2-h interval, respectively). This method has applications in chemical mutagenesis and for studies of molecular changes in brain with sleep/wakefulness.
Safe and effective error rate monitors for SS7 signaling links
NASA Astrophysics Data System (ADS)
Schmidt, Douglas C.
1994-04-01
This paper describes SS7 error monitor characteristics, discusses the existing SUERM (Signal Unit Error Rate Monitor), and develops the recently proposed EIM (Error Interval Monitor) for higher speed SS7 links. A SS7 error monitor is considered safe if it ensures acceptable link quality and is considered effective if it is tolerant to short-term phenomena. Formal criteria for safe and effective error monitors are formulated in this paper. This paper develops models of changeover transients, the unstable component of queue length resulting from errors. These models are in the form of recursive digital filters. Time is divided into sequential intervals. The filter's input is the number of errors which have occurred in each interval. The output is the corresponding change in transmit queue length. Engineered EIM's are constructed by comparing an estimated changeover transient with a threshold T using a transient model modified to enforce SS7 standards. When this estimate exceeds T, a changeover will be initiated and the link will be removed from service. EIM's can be differentiated from SUERM by the fact that EIM's monitor errors over an interval while SUERM's count errored messages. EIM's offer several advantages over SUERM's, including the fact that they are safe and effective, impose uniform standards in link quality, are easily implemented, and make minimal use of real-time resources.
Agreement of Tracing and Direct Viewing Techniques for Cervical Vertebral Maturation Assessment.
Wiwatworakul, Opas; Manosudprasit, Montian; Pisek, Poonsak; Chatrchaiwiwatana, Supaporn; Wangsrimongkol, Tasanee
2015-08-01
This study aimed to evaluate agreement among three methods for cervical vertebral maturation (CVM) assessment, comprising direct viewing, tracing only, and tracing with digitized points. Two examiners received training and tests of reliability with each CVM method before evaluation of agreement among methods. The subjects were 96 female-cleft lateral cephalometric radiographs (films of eight subjects for each age ranged from seven to 18 years). The examiners interpreted CVM stages of the subjects with four-week interval between uses of each method. The range of weighted kappa values for paired comparisons among the three methods were: 0.96-0.98 for direct viewing and tracing only comparison; 0.93-0.94 for direct viewing and tracing with digitized points comparison; and 0.96-0.97 for tracing only and tracing with digitized points comparison. The intraclass correlation coefficient (ICC) value among the three methods was 0.95. These results indicated very good agreement among methods. Use of direct viewing is suitable for CVM assessment without spending more time for tracing. However, the three methods might be used interchangeably.
On the design of recursive digital filters
NASA Technical Reports Server (NTRS)
Shenoi, K.; Narasimha, M. J.; Peterson, A. M.
1976-01-01
A change of variables is described which transforms the problem of designing a recursive digital filter to that of approximation by a ratio of polynomials on a finite interval. Some analytic techniques for the design of low-pass filters are presented, illustrating the use of the transformation. Also considered are methods for the design of phase equalizers.
Vyas, Nikki S.; Markow, Michael; Prieto-Granada, Carlos; Gaudi, Sudeep; Turner, Leslie; Rodriguez-Waitkus, Paul; Messina, Jane L.; Jukic, Drazen M.
2016-01-01
Background: The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. Methods: Hematoxylin and eosin and periodic acid–Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany). Six pathologists assessed 50–71 digital slides. We recorded objective magnification, total time, and detection of the following: Mast cells; eosinophils; plasma cells; pigmented macrophages; melanin in the epidermis; fungal bodies; neutrophils; civatte bodies; parakeratosis; and sebocytes. This process was repeated using the corresponding glass slides after 3 weeks. The diagnosis was not required. Results: The mean time to assess digital slides was 176.77 s and 137.61 s for glass slides (P < 0.001, 99% confidence interval [CI]). The mean objective magnification used to detect features using digital slides was 18.28 and 14.07 for glass slides (P < 0.001, 99.99% CI). Parakeratosis, civatte bodies, pigmented macrophages, melanin in the epidermis, mast cells, eosinophils, plasma cells, and neutrophils, were identified at lower objectives on glass slides (P = 0.023–0.001, 95% CI). Average intraobserver concordance ranged from κ = 0.30 to κ = 0.78. Features with poor to fair average concordance were: Melanin in the epidermis (κ = 0.15–0.58); plasma cells (κ = 0.15–0.49); and neutrophils (κ = 0.12–0.48). Features with moderate average intrapathologist concordance were: parakeratosis (κ = 0.21–0.61); civatte bodies (κ = 0.21–0.71); pigment-laden macrophages (κ = 0.34–0.66); mast cells (κ = 0.29–0.78); and eosinophils (κ = 0.31–0.79). The average intrapathologist concordance was good for sebocytes (κ = 0.51–1.00) and fungal bodies (κ = 0.47–0.76). Conclusions: Telepathology using digital slides scanned at ×20 is sufficient for detection of histopathologic features routinely encountered in dermatitis cases, though less efficient than glass slides. PMID:27563489
Castanera, Diego; Vila, Bernat; Razzolini, Novella L; Falkingham, Peter L; Canudo, José I; Manning, Phillip L; Galobart, Angel
2013-01-01
The Las Cerradicas site (Tithonian-Berriasian), Teruel, Spain, preserves at least seventeen dinosaur trackways, some of them formerly attributed to quadrupedal ornithopods, sauropods and theropods. The exposure of new track evidence allows a more detailed interpretation of the controversial tridactyl trackways as well as the modes of locomotion and taxonomic affinities of the trackmakers. Detailed stratigraphic analysis reveals four different levels where footprints have been preserved in different modes. Within the tridactyl trackways, manus tracks are mainly present in a specific horizon relative to surface tracks. The presence of manus tracks is interpreted as evidence of an ornithopod trackmaker. Cross-sections produced from photogrammetric digital models show different depths of the pes and manus, suggesting covariance in loading between the forelimbs and the hindlimbs. Several features (digital pads, length/width ratio, claw marks) of some ornithopod pes tracks from Las Cerradicas are reminiscent of theropod pedal morphology. This morphological convergence, combined with the shallow nature of the manus tracks, which reduces preservation potential, opens a new window into the interpretation of these tridactyl tracks. Thus, trackmaker assignations during the Jurassic-Cretaceous interval of purported theropod trackways may potentially represent ornithopods. Moreover, the Las Cerradicas trackways are further evidence for quadrupedalism among some basal small- to medium-sized ornithopods from this time interval.
Oversampling of digitized images. [effects on interpolation in signal processing
NASA Technical Reports Server (NTRS)
Fischel, D.
1976-01-01
Oversampling is defined as sampling with a device whose characteristic width is greater than the interval between samples. This paper shows why oversampling should be avoided and discusses the limitations in data processing if circumstances dictate that oversampling cannot be circumvented. Principally, oversampling should not be used to provide interpolating data points. Rather, the time spent oversampling should be used to obtain more signal with less relative error, and the Sampling Theorem should be employed to provide any desired interpolated values. The concepts are applicable to single-element and multielement detectors.
Krstacic, Goran; Krstacic, Antonija; Smalcelj, Anton; Milicic, Davor; Jembrek-Gostovic, Mirjana
2007-04-01
Dynamic analysis techniques may quantify abnormalities in heart rate variability (HRV) based on nonlinear and fractal analysis (chaos theory). The article emphasizes clinical and prognostic significance of dynamic changes in short-time series applied on patients with coronary heart disease (CHD) during the exercise electrocardiograph (ECG) test. The subjects were included in the series after complete cardiovascular diagnostic data. Series of R-R and ST-T intervals were obtained from exercise ECG data after sampling digitally. The range rescaled analysis method determined the fractal dimension of the intervals. To quantify fractal long-range correlation's properties of heart rate variability, the detrended fluctuation analysis technique was used. Approximate entropy (ApEn) was applied to quantify the regularity and complexity of time series, as well as unpredictability of fluctuations in time series. It was found that the short-term fractal scaling exponent (alpha(1)) is significantly lower in patients with CHD (0.93 +/- 0.07 vs 1.09 +/- 0.04; P < 0.001). The patients with CHD had higher fractal dimension in each exercise test program separately, as well as in exercise program at all. ApEn was significant lower in CHD group in both RR and ST-T ECG intervals (P < 0.001). The nonlinear dynamic methods could have clinical and prognostic applicability also in short-time ECG series. Dynamic analysis based on chaos theory during the exercise ECG test point out the multifractal time series in CHD patients who loss normal fractal characteristics and regularity in HRV. Nonlinear analysis technique may complement traditional ECG analysis.
NASA Technical Reports Server (NTRS)
Fichtl, G. H.
1971-01-01
Statistical estimates of wind shear in the planetary boundary layer are important in the design of V/STOL aircraft, and for the design of the Space Shuttle. The data analyzed in this study consist of eleven sets of longitudinal turbulent velocity fluctuation time histories digitized at 0.2 sec intervals with approximately 18,000 data points per time history. The longitudinal velocity fluctuations were calculated with horizontal wind and direction data collected at the 18-, 30-, 60-, 90-, 120-, and 150-m levels. The data obtained confirm the result that Eulerian time spectra transformed to wave-number spectra with Taylor's frozen eddy hypothesis possess inertial-like behavior at wave-numbers well out of the inertial subrange.
Lu, Zhong; Dzurisin, Daniel; Jung, Hyung-Sup; Zhang, Lei; Lee, Wonjin; Lee, Chang-Wook
2012-01-01
An accurate digital elevation model (DEM) is a critical data set for characterizing the natural landscape, monitoring natural hazards, and georeferencing satellite imagery. The ideal interferometric synthetic aperture radar (InSAR) configuration for DEM production is a single-pass two-antenna system. Repeat-pass single-antenna satellite InSAR imagery, however, also can be used to produce useful DEMs. DEM generation from InSAR is advantageous in remote areas where the photogrammetric approach to DEM generation is hindered by inclement weather conditions. There are many sources of errors in DEM generation from repeat-pass InSAR imagery, for example, inaccurate determination of the InSAR baseline, atmospheric delay anomalies, and possible surface deformation because of tectonic, volcanic, or other sources during the time interval spanned by the images. This chapter presents practical solutions to identify and remove various artifacts in repeat-pass satellite InSAR images to generate a high-quality DEM.
NASA Astrophysics Data System (ADS)
Li, Jiaqiang; Choutko, Vitaly; Xiao, Liyi
2018-03-01
Based on the collection of error data from the Alpha Magnetic Spectrometer (AMS) Digital Signal Processors (DSP), on-orbit Single Event Upsets (SEUs) of the DSP program memory are analyzed. The daily error distribution and time intervals between errors are calculated to evaluate the reliability of the system. The particle density distribution of International Space Station (ISS) orbit is presented and the effects from the South Atlantic Anomaly (SAA) and the geomagnetic poles are analyzed. The impact of solar events on the DSP program memory is carried out combining data analysis and Monte Carlo simulation (MC). From the analysis and simulation results, it is concluded that the area corresponding to the SAA is the main source of errors on the ISS orbit. Solar events can also cause errors on DSP program memory, but the effect depends on the on-orbit particle density.
High-Speed, High-Resolution Time-to-Digital Conversion
NASA Technical Reports Server (NTRS)
Katz, Richard; Kleyner, Igor; Garcia, Rafael
2013-01-01
This innovation is a series of time-tag pulses from a photomultiplier tube, featuring short time interval between pulses (e.g., 2.5 ns). Using the previous art, dead time between pulses is too long, or too much hardware is required, including a very-high-speed demultiplexer. A faster method is needed. The goal of this work is to provide circuits to time-tag pulses that arrive at a high rate using the hardwired logic in an FPGA - specifically the carry chain - to create what is (in effect) an analog delay line. High-speed pulses travel down the chain in a "wave." For instance, a pulse train has been demonstrated from a 1- GHz source reliably traveling down the carry chain. The size of the carry chain is over 10 ns in the time domain. Thus, multiple pulses will travel down the carry chain in a wave simultaneously. A register clocked by a low-skew clock takes a "snapshot" of the wave. Relatively simple logic can extract the pulses from the snapshot picture by detecting the transitions between logic states. The propagation delay of CMOS (complementary metal oxide semiconductor) logic circuits will differ and/or change as a result of temperature, voltage, age, radiation, and manufacturing variances. The time-to-digital conversion circuits can be calibrated with test signals, or the changes can be nulled by a separate on-die calibration channel, in a closed loop circuit.
NASA Astrophysics Data System (ADS)
Krider, E. P.; Baffou, G.; Murray, N. D.; Willett, J. C.
2004-12-01
We have analyzed the shapes and other characteristics of the electric field, E, and dE/dt waveforms that were radiated by leader steps just before the first return stroke in cloud-to-ocean lightning. dE/dt waveforms were recorded using an 8-bit digitizer sampling at 100 MHz, and an integrated waveform, Eint, was computed by numerically integrating dE/dt and comparing the result with an analog E waveform digitized at 10 MHz. All signals were recorded under conditions where the lightning locations were known and there was minimal distortion in the fields due to the effects of ground-wave propagation. The dE/dt waveforms radiated by leader steps tend to fall into three categories: (1) "simple" - an isolated negative peak that is immediately followed by a positive overshoot (where negative polarity follows the normal physics convention), (2) "double" - two simple waveforms that occur at almost the same time, and (3) "burst" - a complex cluster of pulses with a total duration of about one microsecond. In this paper, we will give examples of each of these waveform types, and we will summarize their characteristics on a submicrosecond time-scale. For example, in an interval starting 9 μ s before to 4 μ s before the largest, negative (dominant) peak in dE/dt peak in the return stroke, 131 first strokes produced a total of 296 impulses with a peak amplitude greater than 10% of the dominant peak, and the average amplitude of these pulses was 0.21 of the dominant peak. The last leader step in a 12 μ s interval before the dominant peak was a simple waveform in 51 first strokes, and in these cases, the average time-interval between the peak dE/dt of the step and the dominant peak of the stroke was 5.8 ± 1.7 μ s, a value that is in good agreement with prior measurements. The median full-width-at-half-maximum (FWHM) of 274 simple Eint signatures was 141 ns, and the associated mean and standard deviation were 187 ± 131 ns.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Blanking Interval and in the Visual Signal. 73.646 Section 73.646 Telecommunication FEDERAL COMMUNICATIONS... transmission of data, processed information, or any other communication in either a digital or analog mode. (b... kinds of service that may be provided include, but are not limited to, teletext, paging, computer...
Digital Games, Design, and Learning: A Systematic Review and Meta-Analysis.
Clark, Douglas B; Tanner-Smith, Emily E; Killingsworth, Stephen S
2016-03-01
In this meta-analysis, we systematically reviewed research on digital games and learning for K-16 students. We synthesized comparisons of game versus nongame conditions (i.e., media comparisons) and comparisons of augmented games versus standard game designs (i.e., value-added comparisons). We used random-effects meta-regression models with robust variance estimates to summarize overall effects and explore potential moderator effects. Results from media comparisons indicated that digital games significantly enhanced student learning relative to nongame conditions ([Formula: see text] = 0.33, 95% confidence interval [0.19, 0.48], k = 57, n = 209). Results from value-added comparisons indicated significant learning benefits associated with augmented game designs ([Formula: see text] = 0.34, 95% confidence interval [0.17, 0.51], k = 20, n = 40). Moderator analyses demonstrated that effects varied across various game mechanics characteristics, visual and narrative characteristics, and research quality characteristics. Taken together, the results highlight the affordances of games for learning as well as the key role of design beyond medium.
Digital Games, Design, and Learning
Clark, Douglas B.; Tanner-Smith, Emily E.; Killingsworth, Stephen S.
2016-01-01
In this meta-analysis, we systematically reviewed research on digital games and learning for K–16 students. We synthesized comparisons of game versus nongame conditions (i.e., media comparisons) and comparisons of augmented games versus standard game designs (i.e., value-added comparisons). We used random-effects meta-regression models with robust variance estimates to summarize overall effects and explore potential moderator effects. Results from media comparisons indicated that digital games significantly enhanced student learning relative to nongame conditions (g¯ = 0.33, 95% confidence interval [0.19, 0.48], k = 57, n = 209). Results from value-added comparisons indicated significant learning benefits associated with augmented game designs (g¯ = 0.34, 95% confidence interval [0.17, 0.51], k = 20, n = 40). Moderator analyses demonstrated that effects varied across various game mechanics characteristics, visual and narrative characteristics, and research quality characteristics. Taken together, the results highlight the affordances of games for learning as well as the key role of design beyond medium. PMID:26937054
NASA Astrophysics Data System (ADS)
Hatala, J.; Sonnentag, O.; Detto, M.; Runkle, B.; Vargas, R.; Kelly, M.; Baldocchi, D. D.
2009-12-01
Ground-based, visible light imagery has been used for different purposes in agricultural and ecological research. A series of recent studies explored the utilization of networked digital cameras to continuously monitor vegetation by taking oblique canopy images at fixed view angles and time intervals. In our contribution we combine high temporal resolution digital camera imagery, eddy-covariance, and meteorological measurements with weekly field-based hyperspectral and LAI measurements to gain new insights on temporal changes in canopy structure and functioning of two managed ecosystems in California’s Sacramento-San Joaquin River Delta: a pasture infested by the invasive perennial pepperweed (Lepidium latifolium) and a rice plantation (Oryza sativa). Specific questions we address are: a) how does year-round grazing affect pepperweed canopy development, b) is it possible to identify phenological key events of managed ecosystems (pepperweed: flowering; rice: heading) from the limited spectral information of digital camera imagery, c) is a simple greenness index derived from digital camera imagery sufficient to track leaf area index and canopy development of managed ecosystems, and d) what are the scales of temporal correlation between digital camera signals and carbon and water fluxes of managed ecosystems? Preliminary results for the pasture-pepperweed ecosystem show that year-round grazing inhibits the accumulation of dead stalks causing earlier green-up and that digital camera imagery is well suited to capture the onset of flowering and the associated decrease in photosynthetic CO2 uptake. Results from our analyses are of great relevance from both a global environmental change and land management perspective.
Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward
2009-01-01
To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.
Real-time multi-mode neutron multiplicity counter
Rowland, Mark S; Alvarez, Raymond A
2013-02-26
Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.
A microcomputer interface for a digital audio processor-based data recording system.
Croxton, T L; Stump, S J; Armstrong, W M
1987-10-01
An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer.
A microcomputer interface for a digital audio processor-based data recording system.
Croxton, T L; Stump, S J; Armstrong, W M
1987-01-01
An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer. PMID:3676444
Effects of computing time delay on real-time control systems
NASA Technical Reports Server (NTRS)
Shin, Kang G.; Cui, Xianzhong
1988-01-01
The reliability of a real-time digital control system depends not only on the reliability of the hardware and software used, but also on the speed in executing control algorithms. The latter is due to the negative effects of computing time delay on control system performance. For a given sampling interval, the effects of computing time delay are classified into the delay problem and the loss problem. Analysis of these two problems is presented as a means of evaluating real-time control systems. As an example, both the self-tuning predicted (STP) control and Proportional-Integral-Derivative (PID) control are applied to the problem of tracking robot trajectories, and their respective effects of computing time delay on control performance are comparatively evaluated. For this example, the STP (PID) controller is shown to outperform the PID (STP) controller in coping with the delay (loss) problem.
Real-time fluorescence microscopy monitoring of porphyrin biodistribution
NASA Astrophysics Data System (ADS)
Kimel, Sol; Gottfried, Varda; Kunzi-Rapp, Karin; Akguen, Nermin; Schneckenburger, Herbert
1996-01-01
In vivo uptake of the natural porphyrins, uroporphyrin III (UP), coproporphyrin III (CP) and protoporphyrin IX (PP), was monitored by fluorescence microscopy. Experiments were performed using the chick chorioallantoic membrane (CAM) model, which allowed video documentation of fluorescence both in real time and after integration over a chosen time interval (usually 2 s). Sensitizers at a concentration of 50 (mu) M (100 (mu) L) were injected into a medium-sized vein (diameter approximately 40 micrometer) using an ultra-fine 10 micrometer diameter needle. Fluorescence images were quantitated by subtracting the fluorescence intensity of surrounding CAM tissue (Fmatrix) from the intravascular fluorescence intensity (Fintravascular), after transformation of the video frames into digital form. The differential fluorescence intensity, Fintravascular - Fmatrix, is a measure of the biodistribution. Real time measurements clearly showed that CP and UP fluorescence is associated with moving erythrocytes and not with endothelial cells of the vessel wall. Fluorescence intensity was monitored, up to 60 minutes after injection, by averaging the fluorescence over time intervals of 2 s and recording the integrated images. The fluorescence intensity reached its maximum in about 20 - 30 min after injection, presumably after monomerization inside erythrocyte membranes. The results are interpreted in terms of physical-chemical characteristics (e.g. hydrophilicity) and correlated with the photodynamically induced hemostasis in CAM blood vessels.
Raghunath, Vignesh; Braxton, Melissa O.; Gagnon, Stephanie A.; Brunyé, Tad T.; Allison, Kimberly H.; Reisch, Lisa M.; Weaver, Donald L.; Elmore, Joann G.; Shapiro, Linda G.
2012-01-01
Context: Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists’ viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists’ viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists’ viewing strategies and time expenditures in their interpretive workflow. Aims: To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists’ attention and viewing behavior. Settings and Design: Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Materials and Methods: Participants’ foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Statistical Analysis Used: Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists’ accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Results: Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Conclusions: Data detailing mouse cursor movements may be a useful addition to future studies of pathologists’ accuracy and efficiency when using digital pathology. PMID:23372984
Raghunath, Vignesh; Braxton, Melissa O; Gagnon, Stephanie A; Brunyé, Tad T; Allison, Kimberly H; Reisch, Lisa M; Weaver, Donald L; Elmore, Joann G; Shapiro, Linda G
2012-01-01
Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists' viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists' viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists' viewing strategies and time expenditures in their interpretive workflow. To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists' attention and viewing behavior. Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Participants' foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists' accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Data detailing mouse cursor movements may be a useful addition to future studies of pathologists' accuracy and efficiency when using digital pathology.
Harrison, Arnell S.; Dadisman, Shawn V.; McBride, W. Scott; Flocks, James G.; Wiese, Dana S.
2009-01-01
In May of 2008, the U.S. Geological Survey (USGS) conducted geophysical surveys in Lake Panasoffkee, located in central Florida, as part of the USGS Lakes and Coastal Aquifers (LCA) study. This report serves as an archive of unprocessed digital boomer and Compressed High Intensity Radar Pulse (CHIRP)* seismic reflection data, trackline maps, navigation files, Field Activity Collection System (FACS) logs, Geographic Information System (GIS) files, and formal Federal Geographic Data Committee (FGDC) metadata. Filtered and gained (a relative increase in signal amplitude) digital images of the seismic profiles and geospatially corrected interactive profiles are also provided. Refer to the Acronyms page for expansions of acronyms and abbreviations used in this report. *Due to poor data acquisition conditions associated with the lake bottom sediments, only two CHIRP tracklines were collected during this field activity. The archived trace data are in standard Society of Exploration Geophysicists (SEG) SEG-Y format (Barry and others, 1975) and may be downloaded and processed with commercial or public domain software such as Seismic Unix (SU). Example SU processing scripts and USGS software for viewing the SEG-Y files (Zihlman, 1992) are provided. The USGS Florida Integrated Science Center (FISC) - St. Petersburg assigns a unique identifier to each cruise or field activity. For example, 08LCA03 tells us the data were collected in 2008 for the Lakes and Coastal Aquifers (LCA) study and the data were collected during the third field activity for that study in that calendar year. Refer to http://walrus.wr.usgs.gov/infobank/programs/html/definition/activity.html for a detailed description of the method used to assign the field activity ID. The naming convention used for each seismic line is as follows: yye##a, where 'yy' are the last two digits of the year in which the data were collected, 'e' is a 1-letter abbreviation for the equipment type (for example, b for boomer and c for CHIRP), '##' is a 2-digit number representing a specific track, and 'a' is a letter representing the section of a line if recording was prematurely terminated or rerun for quality or acquisition problems. The boomer plate is an acoustic energy source that consists of capacitors charged to a high voltage and discharged through a transducer in the water. The transducer is towed on a sled floating on the water surface and, when discharged, emits a short acoustic pulse, or shot, which propagates through the water, sediment column, or rock beneath. The acoustic energy is reflected at density boundaries (such as the seafloor, sediment, or rock layers beneath the seafloor), detected by the receiver, and recorded by a PC-based seismic acquisition system. This process is repeated at timed intervals (for example, 0.5 s) and recorded for specific intervals of time (for example, 100 ms). In this way, a two-dimensional (2-D) vertical profile of the shallow geologic structure beneath the ship track is produced. Figure 1 displays the boomer acquisition geometry. The EdgeTech SB-424 CHIRP system used for this survey has a vertical resolution of 4 - 8 cm, a penetration depth that is usually less than 2 m beneath the seafloor, and uses a signal of continuously varying frequency. The towfish is a sound source and receiver, which is typically towed 2 - 5 m above the seafloor. The acoustic energy is reflected at density boundaries (such as the seafloor or sediment layers beneath the seafloor), detected by a receiver, and recorded by a PC-based seismic acquisition system. This process is repeated at timed intervals (for example, 0.125 s) and recorded for specific intervals of time (for example, 50 ms); the resulting profile is a two-dimensional vertical image of the shallow geologic structure beneath the ship track. Figure 2 displays the acquisition geometry for the CHIRP system. Refer to table 1 for a summary of acquisition parameters and table 2 for trackline statistics.
Finley, Jason R; Brewer, William F; Benjamin, Aaron S
2011-10-01
Emerging "life-logging" technologies have tremendous potential to augment human autobiographical memory by recording and processing vast amounts of information from an individual's experiences. In this experiment undergraduate participants wore a SenseCam, a small, sensor-equipped digital camera, as they went about their normal daily activities for five consecutive days. Pictures were captured either at fixed intervals or as triggered by SenseCam's sensors. On two of five nights, participants watched an end-of-day review of a random subset of pictures captured that day. Participants were tested with a variety of memory measures at intervals of 1, 3, and 8 weeks. The most fruitful of six measures were recognition rating (on a 1-7 scale) and picture-cued recall length. On these tests, end-of-day review enhanced performance relative to no review, while pictures triggered by SenseCam's sensors showed little difference in performance compared to those taken at fixed time intervals. We discuss the promise of SenseCam as a tool for research and for improving autobiographical memory.
Symbol lock detection implemented with nonoverlapping integration intervals
NASA Technical Reports Server (NTRS)
Shihabi, Mazen M. (Inventor); Hinedi, Sami M. (Inventor); Shah, Biren N. (Inventor)
1995-01-01
A symbol lock detector is introduced for an incoming coherent digital communication signal which utilizes a subcarrier modulated with binary symbol data, d(sub k), and known symbol interval T by integrating binary values of the signal over nonoverlapping first and second intervals selected to be T/2, delaying the first integral an interval T/2, and either summing or multiplying the second integral with the first one that preceded it to form a value X(sub k). That value is then averaged over a number M of symbol intervals to produce a static value Y. A symbol lock decision can then be made when the static value Y exceeds a threshold level delta.
Marinaccio, Christian; Giudice, Giuseppe; Nacchiero, Eleonora; Robusto, Fabio; Opinto, Giuseppina; Lastilla, Gaetano; Maiorano, Eugenio; Ribatti, Domenico
2016-08-01
The presence of interval sentinel lymph nodes in melanoma is documented in several studies, but controversies still exist about the management of these lymph nodes. In this study, an immunohistochemical evaluation of tumor cell proliferation and neo-angiogenesis has been performed with the aim of establishing a correlation between these two parameters between positive and negative interval sentinel lymph nodes. This retrospective study reviewed data of 23 patients diagnosed with melanoma. Bioptic specimens of interval sentinel lymph node were retrieved, and immunohistochemical reactions on tissue sections were performed using Ki67 as a marker of proliferation and CD31 as a blood vessel marker for the study of angiogenesis. The entire stained tissue sections for each case were digitized using Aperio Scanscope Cs whole-slide scanning platform and stored as high-resolution images. Image analysis was carried out on three selected fields of equal area using IHC Nuclear and Microvessel analysis algorithms to determine positive Ki67 nuclei and vessel number. Patients were divided into positive and negative interval sentinel lymph node groups, and the positive interval sentinel lymph node group was further divided into interval positive with micrometastasis and interval positive with macrometastasis subgroups. The analysis revealed a significant difference between positive and negative interval sentinel lymph nodes in the percentage of Ki67-positive nuclei and mean vessel number suggestive of an increased cellular proliferation and angiogenesis in positive interval sentinel lymph nodes. Further analysis in the interval positive lymph node group showed a significant difference between micro- and macrometastasis subgroups in the percentage of Ki67-positive nuclei and mean vessel number. Percentage of Ki67-positive nuclei was increased in the macrometastasis subgroup, while mean vessel number was increased in the micrometastasis subgroup. The results of this study suggest that the correlation between tumor cell proliferation and neo-angiogenesis in interval sentinel lymph nodes in melanoma could be used as a good predictive marker to distinguish interval positive sentinel lymph nodes with micrometastasis from interval positive lymph nodes with macrometastasis subgroups.
Sound levels in conservative dentistry and endodontics clinic
Dutta, Arindam; Mala, Kundabala; Acharya, Shashi Rashmi
2013-01-01
Aim: To evaluate the sound levels generated in dental clinics of conservative dentistry and endodontics. Material and Methods: A decibel-meter with digital readout was used to measure sound levels at different time intervals at the chairside and at the center of the clinic. Minimum and maximum readings during a 3 min interval were recorded. Results: In the post-graduate (PG) clinic, there was significant difference in noise levels between the chairside (66-81 dB[A]) and the center of the clinic (66-67 dB[A]) at certain times. In the under graduate (UG) clinic, noise levels with suction and either high/slow speed handpieces (67-80 dB[A]) were significantly higher than the center of clinic. Suction alone in the UG clinic (63-75 dB[A]) was significantly quieter than in the PG clinic (69-79 dB[A]). Conclusions: (1) Mean sound levels in the working clinics ranged from 63.0 dB[A] to 81.5 dB[A]. These are within the recommended range for dental equipment. (2) With suction and either low/high speed handpiece combination, the PG clinic was significantly noisier than the UG clinic at several time periods. PMID:23716962
Subino, Janice A.; Dadisman, Shawn V.; Wiese, Dana S.; Calderon, Karynna; Phelps, Daniel C.
2009-01-01
In July of 2000, the U.S. Geological Survey (USGS), in cooperation with the Florida Geological Survey (FGS), conducted a geophysical survey of the Atlantic Ocean offshore Florida's east coast from Brevard County to northern Martin County. This report serves as an archive of unprocessed digital boomer seismic reflection data, trackline maps, navigation files, Geographic Information System (GIS) information, digital and handwritten Field Activity Collection System (FACS) logs, and Federal Geographic Data Committee (FGDC) metadata. A filtered and gained (a relative increase in signal amplitude) digital image of each seismic profile is also provided. Refer to the Acronyms page for expansions of all acronyms and abbreviations used in this report. The archived trace data are in standard Society of Exploration Geophysicists (SEG) SEG-Y format (Barry and others, 1975) and may be downloaded and processed with commercial or public domain software such as Seismic Unix (SU) (Cohen and Stockwell, 2005). Example SU processing scripts and USGS Software for viewing the SEG-Y files (Zihlman, 1992) are also provided. The USGS St. Petersburg Coastal and Marine Science Center assigns a unique identifier to each cruise or field activity. For example, 00FGS01 tells us the data were collected in 2000 for cooperative work with the Florida Geological Survey (FGS) and the data were collected during the first field activity for that study in that calendar year. Refer to http://walrus.wr.usgs.gov/infobank/programs/html/definition/activity.html for a detailed description of the method used to assign the field activity ID. The boomer plate is an acoustic energy source that consists of capacitors charged to a high voltage and discharged through a transducer in the water. The transducer is towed on a sled floating on the water surface and when discharged, emits a short acoustic pulse, or shot, which propagates through the water, sediment column, or rock beneath. The acoustic energy is reflected at density boundaries (such as the seafloor, sediment, or rock layers beneath the seafloor), detected by the receiver, and recorded by a PC-based seismic acquisition system. This process is repeated at timed intervals (for example, 0.5 s) and recorded for specific intervals of time (for example, 100 ms). In this way, a two-dimensional (2D) vertical profile of the shallow geologic structure beneath the ship track is produced. Figure 1 displays the acquisition geometry. Refer to table 1 for a summary of acquisition parameters. The unprocessed seismic data are stored in SEG-Y format (Barry and others, 1975). For a detailed description of the data format, refer to the SEG-Y Format page. See the How To Download SEG-Y Data page for download instructions. The printable profiles provided are GIF images that were filtered and gained using Seismic Unix software. Refer to the Software page for details about the processing and examples of the processing scripts. The printable profiles can be viewed from the Profiles page or from links located on the trackline maps. To view the trackline maps and navigation files, and for more information about these items, see the Navigation page. Detailed information about the navigation system used can be found in table 1. Of a total record length of 200 ms, only the upper 100 ms of each profile are displayed because no useful information was observed deeper in the sections. A 10 ms deep water delay appears on lines b57-b63 and sl2-sl28. No digital data were collected for line sl6. However, line sl6r is a second attempt to collect digital data for this line. Digital data and 500-shot-interval location navigation are not available for the last 1,161 shots of line sl26 due to an equipment malfunction.
Bunting, Michael F; Cowan, Nelson; Colflesh, Greg H
2008-06-01
Memory at times depends on attention, as when attention is used to encode incoming, serial verbal information. When encoding and rehearsal are difficult or when attention is divided during list presentation, more attention is needed in the time following the presentation and just preceding the response. Across 12 experimental conditions observed in several experiments, we demonstrated this by introducing a nonverbal task with three levels of effort (no task, a natural nonverbal task, or an unnatural version of the task) during a brief retention interval in a short-term digit recall task. Interference from the task during the retention interval was greater when resources were drawn away from the encoding of the stimuli by other factors, including unpredictability of the end point of the list, rapid presentation, and a secondary task during list presentation. When those conditions complicate encoding of the list, we argue, attention is needed after the list so that the contents of passive memory (i.e., postcategorical phonological storage and/or precategorical sensory memory) may be retrieved and become the focus of attention for recall.
Measurement of high-resolution mechanical contraction of cardiac muscle by induced eddy current.
Lee, Young-Jae; Lee, Kang-Hwi; Kang, Seung-Jin; Kim, Kyeung-Nam; Khang, Seonah; Koo, Hye Ran; Gi, Sunok; Lee, Joo Hyeon; Lee, Jeong-Whan
2014-01-01
There are many types of devices which help to manage a personal health conditions such as heartbeat chest belt, pedometer and smart watch. And the most common device has the relationship with heart rate or ECG data. However, users have to attach some electrode or fasten the belt on the bare skin to measure bio-signal information. Therefore, most of people want more convenient and short-ready-time and no-need to attach electrode. In this paper, we proposed the high-resolution measuring system of mechanical activity of cardiac muscle and thereby measure heartbeat. The principle of the proposed measuring method is that the alternating current generate alternating magnetic field around coil. This primary magnetic field induces eddy current which makes magnetic field against primary coil in the nearby objects. To measure high-resolution changes of the induced secondary magnetic fields, we used digital Phase-locked loop(PLL) circuit which provides more high-resolution traces of frequency changes than the previous studies based on digital frequency counter method. As a result of our preliminary experiment, peak-peak intervals of the proposed method showed high correlation with R-R intervals of clinical ECG signals(r=0.9249). Also, from signal traces of the proposed method, we might make a conjecture that the contraction of atrium or ventricle is reflected by changing conductivity of cardiac muscle which is beating ceaselessly.
Virtual Global Magnetic Observatory - Concept and Implementation
NASA Astrophysics Data System (ADS)
Papitashvili, V.; Clauer, R.; Petrov, V.; Saxena, A.
2002-12-01
The existing World Data Centers (WDC) continue to serve excellently the worldwide scientific community in providing free access to a huge number of global geophysical databases. Various institutions at different geographic locations house these Centers, mainly organized by a scientific discipline. However, population of the Centers requires mandatory or voluntary submission of locally collected data. Recently many digital geomagnetic datasets have been placed on the World Wide Web and some of these sets have not been even submitted to any data center. This has created an urgent need for more sophisticated search engines capable of identifying geomagnetic data on the Web and then retrieving a certain amount of data for the scientific analysis. In this study, we formulate a concept of the virtual global magnetic observatory (VGMO) that currently uses a pre-set list of the Web-based geomagnetic data holders (including WDC) as retrieving a requested case-study interval. Saving the retrieved data locally over the multiple requests, a VGMO user begins to build his/her own data sub-center, which does not need to search the Web if the newly requested interval will be within a span of the earlier retrieved data. At the same time, this self-populated sub-center becomes available to other VGMO users down on the requests chain. Some aspects of the Web``crawling'' helping to identify the newly ``webbed'' digital geomagnetic data are also considered.
,
1993-01-01
The Earth Science Information Center (ESIC) distributes digital cartographic/geographic data files produced by the U.S. Geological Survey (USGS) as part of the National Mapping Program. Digital cartographic data files may be grouped into four basic types. The first of these, called a Digital Line Graph (DLG), is the line map information in digital form. These data files include information on base data categories, such as transportation, hypsography, hydrography, and boundaries. The second type, called a Digital Elevation Model (DEM), consists of a sampled array of elevations for a number of ground positions at regularly spaced intervals. The third type is Land Use and Land Cover digital data which provides information on nine major classes of land use such as urban, agricultural, or forest as well as associated map data such as political units and Federal land ownership. The fourth type, the Geographic Names Information System, provides primary information for all known places, features, and areas in the United States identified by a proper name.
Digital line graphs from 1:24,000-scale maps
,
1990-01-01
The Earth Science Information Centers (ESIC) distribute digital cartographic/geographic data files produced by the U.S. Geological Survey (USGS) as part of the National Mapping Program. Digital cartographic data flles are grouped into four basic types. The first of these, called a Digital Line . Graph (DLG), is line map information in digital form. These data files include information on planimetric base categories, such as transportation, hydrography, and boundaries. The second type, called a Digital Elevation Model (DEM), consists of a sampled array of elevations for a number of ground positions that are usually at regularly spaced intervals. The third type is Land Use and Land Cover digital data, which provides information on nine major classes of land use such as urban, agricultural, or forest as wen as associated map data such as political units and Federal land ownership. The fourth type, the Geographic Names Information System, provides primary information for all known places, features, and areas in the United States identified by a proper name.
Digital line graphs from 1:100,000-scale maps
,
1989-01-01
The National Cartographic Information Center (NCIC) distributes digital cartographic/geographic data files produced by the U.S. Geological Survey (USGS) as part of the National Mapping Program. Digital cartographic data files may be grouped into four basic types. The first of these, called a Digital Line Graph (DLG), is line map information in digital form. These data files include information on planimetric base categories, such as transportation, hydrography, and boundaries. The second form, called a Digital Elevation Model (OEM), consists of a sampled array of elevations for ground positions that are usually, but not always, at regularly spaced intervals. The third type is Land Use and Land Cover digital data, which provides information on nine major classes of land use such as urban, agricultural, or forest as well as associated map data such as political units and Federal land ownership. The fourth type, the Geographic Names Information System, provides primary information for known places, features, and areas in the United States identified by a proper name.
NASA Technical Reports Server (NTRS)
Sadeh, D.; Shannon, D. C.; Abboud, S.; Akselrod, S.; Cohen, R. J.
1987-01-01
The ability of the autonomic nervous system to alter the QT interval in response to heart rate changes is essential to cardiovascular control. An accurate way to determine the relation between QT intervals and their corresponding RR intervals is described. A computer algorithm measures the RR intervals using digital filtering and cross-correlating the QRS sections of consecutive waveforms. The QT intervals is calculated by choosing a section of, the ECG that includes the T wave and cross-correlating it with all the consecutive T waves. At least 4000 pairs of QT-RR intervals are computed for each subject and a best fit correlation function determines the relations between the QT and RR intervals. This technique enables to establish a precise correlation between RR and QT in order to distinguish between control and SIDS babies.
NASA Astrophysics Data System (ADS)
Ahn, Y.; Box, J. E.; Balog, J.; Lewinter, A.
2008-12-01
Monitoring Greenland outlet glaciers using remotely sensed data has drawn a great attention in earth science communities for decades and time series analysis of sensory data has provided important variability information of glacier flow by detecting speed and thickness changes, tracking features and acquiring model input. Thanks to advancements of commercial digital camera technology and increased solid state storage, we activated automatic ground-based time-lapse camera stations with high spatial/temporal resolution in west Greenland outlet and collected one-hour interval data continuous for more than one year at some but not all sites. We believe that important information of ice dynamics are contained in these data and that terrestrial mono-/stereo-photogrammetry can provide theoretical/practical fundamentals in data processing along with digital image processing techniques. Time-lapse images over periods in west Greenland indicate various phenomenon. Problematic is rain, snow, fog, shadows, freezing of water on camera enclosure window, image over-exposure, camera motion, sensor platform drift, and fox chewing of instrument cables, and the pecking of plastic window by ravens. Other problems include: feature identification, camera orientation, image registration, feature matching in image pairs, and feature tracking. Another obstacle is that non-metric digital camera contains large distortion to be compensated for precise photogrammetric use. Further, a massive number of images need to be processed in a way that is sufficiently computationally efficient. We meet these challenges by 1) identifying problems in possible photogrammetric processes, 2) categorizing them based on feasibility, and 3) clarifying limitation and alternatives, while emphasizing displacement computation and analyzing regional/temporal variability. We experiment with mono and stereo photogrammetric techniques in the aide of automatic correlation matching for efficiently handling the enormous data volumes.
User's manual for SEDCALC, a computer program for computation of suspended-sediment discharge
Koltun, G.F.; Gray, John R.; McElhone, T.J.
1994-01-01
Sediment-Record Calculations (SEDCALC), a menu-driven set of interactive computer programs, was developed to facilitate computation of suspended-sediment records. The programs comprising SEDCALC were developed independently in several District offices of the U.S. Geological Survey (USGS) to minimize the intensive labor associated with various aspects of sediment-record computations. SEDCALC operates on suspended-sediment-concentration data stored in American Standard Code for Information Interchange (ASCII) files in a predefined card-image format. Program options within SEDCALC can be used to assist in creating and editing the card-image files, as well as to reformat card-image files to and from formats used by the USGS Water-Quality System. SEDCALC provides options for creating card-image files containing time series of equal-interval suspended-sediment concentrations from 1. digitized suspended-sediment-concentration traces, 2. linear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals, and 3. nonlinear interpolation between log-transformed instantaneous suspended-sediment-concentration data stored at unequal time intervals. Suspended-sediment discharge can be computed from the streamflow and suspended-sediment-concentration data or by application of transport relations derived by regressing log-transformed instantaneous streamflows on log-transformed instantaneous suspended-sediment concentrations or discharges. The computed suspended-sediment discharge data are stored in card-image files that can be either directly imported to the USGS Automated Data Processing System or used to generate plots by means of other SEDCALC options.
Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors
NASA Astrophysics Data System (ADS)
Luo, X. L.; Modamio, V.; Nyberg, J.; Valiente-Dobón, J. J.; Nishada, Q.; de Angelis, G.; Agramunt, J.; Egea, F. J.; Erduran, M. N.; Ertürk, S.; de France, G.; Gadea, A.; González, V.; Goasduff, A.; Hüyük, T.; Jaworski, G.; Moszyński, M.; Di Nitto, A.; Palacz, M.; Söderström, P.-A.; Sanchis, E.; Triossi, A.; Wadsworth, R.
2018-07-01
The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and γ standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or γ rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron- γ discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
Movafegh, Ali; Alizadeh, Reza; Hajimohamadi, Fatimah; Esfehani, Fatimah; Nejatfar, Mohmad
2008-06-01
Many patients have preoperative anxiety; therefore, the development of a strong anxiolytic with minimal psychomotor impairment for premedication may be desirable. In this study, 60 patients were randomized into two groups to receive either oral Passiflora incarnata (500 mg, Passipy IranDarouk) (n = 30) or placebo (n = 30) as premedication, 90 min before surgery. A numerical rating scale (NRS) was used for each patient to assess anxiety and sedation before, and 10, 30, 60, and 90 min after premedication. Psychomotor function was assessed with the Trieger Dot Test and the Digit-Symbol Substitution Test at arrival in the operating room, 30 and 90 min after tracheal extubation. The time interval between arrival in the postanesthesia care unit and discharge to home (discharge time) was recorded for each patient. The demographic characteristics of patients, ASA physical status, duration of surgery, basal NRS score, sedation at the preset time intervals, and discharge time were similar in the two groups. The NRS anxiety scores were significantly lower in the passiflora group than in the control group (P < 0.001). There were no significant differences in psychological variables in the postanesthesia care unit and recovery of psychomotor function was comparable in both groups. In outpatient surgery, administration of oral Passiflora incarnata as a premedication reduces anxiety without inducing sedation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakanishi, Masakazu, E-mail: m.nakanishi@aist.go.jp
Responses of a superconducting quantum interference device (SQUID) are periodically dependent on magnetic flux coupling to its superconducting ring and the period is a flux quantum (Φ{sub o} = h/2e, where h and e, respectively, express Planck's constant and elementary charge). Using this periodicity, we had proposed a digital to analog converter using a SQUID (SQUID DAC) of first generation with linear current output, interval of which corresponded to Φ{sub o}. Modification for increasing dynamic range by interpolating within each interval is reported. Linearity of the interpolation was also based on the quantum periodicity. A SQUID DAC with dynamic rangemore » of about 1.4 × 10{sup 7} was created as a demonstration.« less
A comparison of pairs figure skaters in repeated jumps.
Sands, William A; Kimmel, Wendy L; McNeal, Jeni R; Murray, Steven Ross; Stone, Michael H
2012-01-01
Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg) calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA) showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare. Key pointsThe repeated jumps test can account for about 50% of the variance in pairs ranks.Changes in technique are largely due to fatigue, but the athletes were able to maintain a maximum flexion knee angle very close to the desired 90 degrees. Changes in angular velocity and jump heights occurred as expected, again probably due to fatigue.As expected from metabolic information, the athletes' power indexes peak around 20s and decline thereafter. Coaches should be aware of this time as a boundary beyond which fatigue becomes more manifest, and use careful choreographic choices to provide rest periods that are disguised as less demanding skating elements to afford recovery.The repeated jumps test may be a helpful off-ice test of power-endurance for figure skaters.
NASA Astrophysics Data System (ADS)
Passmore, P. R.; Jackson, M.; Zimakov, L. G.; Raczka, J.; Davidson, P.
2014-12-01
The key requirements for Earthquake Early Warning and other Rapid Event Notification Systems are: Quick delivery of digital data from a field station to the acquisition and processing center; Data integrity for real-time earthquake notification in order to provide warning prior to significant ground shaking in the given target area. These two requirements are met in the recently developed Trimble SG160-09 SeismoGeodetic System, which integrates both GNSS and acceleration measurements using the Kalman filter algorithm to create a new high-rate (200 sps), real-time displacement with sufficient accuracy and very low latency for rapid delivery of the acquired data to a processing center. The data acquisition algorithm in the SG160-09 System provides output of both acceleration and displacement digital data with 0.2 sec delay. This is a significant reduction in the time interval required for real-time transmission compared to data delivery algorithms available in digitizers currently used in other Earthquake Early Warning networks. Both acceleration and displacement data are recorded and transmitted to the processing site in a specially developed Multiplexed Recording Format (MRF) that minimizes the bandwidth required for real-time data transmission. In addition, a built in algorithm calculates the τc and Pd once the event is declared. The SG160-09 System keeps track of what data has not been acknowledged and re-transmits the data giving priority to current data. Modified REF TEK Protocol Daemon (RTPD) receives the digital data and acknowledges data received without error. It forwards this "good" data to processing clients of various real-time data processing software including Earthworm and SeisComP3. The processing clients cache packets when a data gap occurs due to a dropped packet or network outage. The cache packet time is settable, but should not exceed 0.5 sec in the Earthquake Early Warning network configuration. The rapid data transmission algorithm was tested with different communication media, including Internet, DSL, Wi-Fi, GPRS, etc. The test results show that the data latency via most communication media do not exceed 0.5 sec nominal from a first sample in the data packet. Detailed acquisition algorithm and results of data transmission via different communication media are presented.
Echavarría-Heras, Héctor; Leal-Ramírez, Cecilia; Villa-Diharce, Enrique; Castillo, Oscar
2014-01-01
Eelgrass is a cosmopolitan seagrass species that provides important ecological services in coastal and near-shore environments. Despite its relevance, loss of eelgrass habitats is noted worldwide. Restoration by replanting plays an important role, and accurate measurements of the standing crop and productivity of transplants are important for evaluating restoration of the ecological functions of natural populations. Traditional assessments are destructive, and although they do not harm natural populations, in transplants the destruction of shoots might cause undesirable alterations. Non-destructive assessments of the aforementioned variables are obtained through allometric proxies expressed in terms of measurements of the lengths or areas of leaves. Digital imagery could produce measurements of leaf attributes without the removal of shoots, but sediment attachments, damage infringed by drag forces or humidity contents induce noise-effects, reducing precision. Available techniques for dealing with noise caused by humidity contents on leaves use the concepts of adjacency, vicinity, connectivity and tolerance of similarity between pixels. Selection of an interval of tolerance of similarity for efficient measurements requires extended computational routines with tied statistical inferences making concomitant tasks complicated and time consuming. The present approach proposes a simplified and cost-effective alternative, and also a general tool aimed to deal with any sort of noise modifying eelgrass leaves images. Moreover, this selection criterion relies only on a single statistics; the calculation of the maximum value of the Concordance Correlation Coefficient for reproducibility of observed areas of leaves through proxies obtained from digital images. Available data reveals that the present method delivers simplified, consistent estimations of areas of eelgrass leaves taken from noisy digital images. Moreover, the proposed procedure is robust because both the optimal interval of tolerance of similarity and the reproducibility of observed leaf areas through digital image surrogates were independent of sample size. The present method provides simplified, unbiased and non-destructive measurements of eelgrass leaf area. These measurements, in conjunction with allometric methods, can predict the dynamics of eelgrass biomass and leaf growth through indirect techniques, reducing the destructive effect of sampling, fundamental to the evaluation of eelgrass restoration projects thereby contributing to the conservation of this important seagrass species.
Park, Ji Hyun; Hwang, Gyu-Sam
2016-08-01
A blood pressure (BP) waveform contains various pieces of information related to respiratory variation. Systolic time interval (STI) reflects myocardial performance, and diastolic time interval (DTI) represents diastolic filling. This study examined whether respiratory variations of STI and DTI within radial arterial waveform are comparable to dynamic indices. During liver transplantation, digitally recorded BP waveform and stroke volume variation (SVV) were retrospectively analyzed. Beat-to-beat STI and DTI were extracted within each BP waveform, which were separated by dicrotic notch. Systolic time variation (STV) was calculated by the average of 3 consecutive respiratory cycles: [(STImax- STImin)/STImean]. Similar formula was used for diastolic time variation (DTV) and pulse pressure variation (PPV). Receiver operating characteristic analysis with area under the curve (AUC) was used to assess thresholds predictive of SVV ≥12% and PPV ≥12%. STV and DTV showed significant correlations with SVV (r= 0.78 and r= 0.67, respectively) and PPV (r= 0.69 and r= 0.69, respectively). Receiver operating characteristic curves demonstrated that STV ≥11% identified to predict SVV ≥12% with 85.7% sensitivity and 89.3% specificity (AUC = 0.935; P< .001). DTV ≥11% identified to predict SVV ≥12% with 71.4% sensitivity and 85.7% specificity (AUC = 0.829; P< .001). STV ≥12% and DTV ≥11% identified to predict PPV ≥12% with an AUC of 0.881 and 0.885, respectively. Respiratory variations of STI and DTI derived from radial arterial contour have a potential to predict hemodynamic response as a surrogate for SVV or PPV. Copyright © 2016 Elsevier Inc. All rights reserved.
Temporal precision and the capacity of auditory-verbal short-term memory.
Gilbert, Rebecca A; Hitch, Graham J; Hartley, Tom
2017-12-01
The capacity of serially ordered auditory-verbal short-term memory (AVSTM) is sensitive to the timing of the material to be stored, and both temporal processing and AVSTM capacity are implicated in the development of language. We developed a novel "rehearsal-probe" task to investigate the relationship between temporal precision and the capacity to remember serial order. Participants listened to a sub-span sequence of spoken digits and silently rehearsed the items and their timing during an unfilled retention interval. After an unpredictable delay, a tone prompted report of the item being rehearsed at that moment. An initial experiment showed cyclic distributions of item responses over time, with peaks preserving serial order and broad, overlapping tails. The spread of the response distributions increased with additional memory load and correlated negatively with participants' auditory digit spans. A second study replicated the negative correlation and demonstrated its specificity to AVSTM by controlling for differences in visuo-spatial STM and nonverbal IQ. The results are consistent with the idea that a common resource underpins both the temporal precision and capacity of AVSTM. The rehearsal-probe task may provide a valuable tool for investigating links between temporal processing and AVSTM capacity in the context of speech and language abilities.
Multi-channel photon counting DOT system based on digital lock-in detection technique
NASA Astrophysics Data System (ADS)
Wang, Tingting; Zhao, Huijuan; Wang, Zhichao; Hou, Shaohua; Gao, Feng
2011-02-01
Relying on deeper penetration of light in the tissue, Diffuse Optical Tomography (DOT) achieves organ-level tomography diagnosis, which can provide information on anatomical and physiological features. DOT has been widely used in imaging of breast, neonatal cerebral oxygen status and blood oxygen kinetics observed by its non-invasive, security and other advantages. Continuous wave DOT image reconstruction algorithms need the measurement of the surface distribution of the output photon flow inspired by more than one driving source, which means that source coding is necessary. The most currently used source coding in DOT is time-division multiplexing (TDM) technology, which utilizes the optical switch to switch light into optical fiber of different locations. However, in case of large amounts of the source locations or using the multi-wavelength, the measurement time with TDM and the measurement interval between different locations within the same measurement period will therefore become too long to capture the dynamic changes in real-time. In this paper, a frequency division multiplexing source coding technology is developed, which uses light sources modulated by sine waves with different frequencies incident to the imaging chamber simultaneously. Signal corresponding to an individual source is obtained from the mixed output light using digital phase-locked detection technology at the detection end. A digital lock-in detection circuit for photon counting measurement system is implemented on a FPGA development platform. A dual-channel DOT photon counting experimental system is preliminary established, including the two continuous lasers, photon counting detectors, digital lock-in detection control circuit, and codes to control the hardware and display the results. A series of experimental measurements are taken to validate the feasibility of the system. This method developed in this paper greatly accelerates the DOT system measurement, and can also obtain the multiple measurements in different source-detector locations.
Fink, Christian; Hallscheidt, Peter J; Noeldge, Gerd; Kampschulte, Annette; Radeleff, Boris; Hosch, Waldemar P; Kauffmann, Günter W; Hansmann, Jochen
2002-02-01
The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.
Lee, N J; Chung, M S; Jung, S C; Kim, H S; Choi, C-G; Kim, S J; Lee, D H; Suh, D C; Kwon, S U; Kang, D-W; Kim, J S
2016-12-01
High-resolution MR imaging has recently been introduced as a promising diagnostic modality in intracranial artery disease. Our aim was to compare high-resolution MR imaging with digital subtraction angiography for the characterization and diagnosis of various intracranial artery diseases. Thirty-seven patients who had undergone both high-resolution MR imaging and DSA for intracranial artery disease were enrolled in our study (August 2011 to April 2014). The time interval between the high-resolution MR imaging and DSA was within 1 month. The degree of stenosis and the minimal luminal diameter were independently measured by 2 observers in both DSA and high-resolution MR imaging, and the results were compared. Two observers independently diagnosed intracranial artery diseases on DSA and high-resolution MR imaging. The time interval between the diagnoses on DSA and high-resolution MR imaging was 2 weeks. Interobserver diagnostic agreement for each technique and intermodality diagnostic agreement for each observer were acquired. High-resolution MR imaging showed moderate-to-excellent agreement (interclass correlation coefficient = 0.892-0.949; κ = 0.548-0.614) and significant correlations (R = 0.766-892) with DSA on the degree of stenosis and minimal luminal diameter. The interobserver diagnostic agreement was good for DSA (κ = 0.643) and excellent for high-resolution MR imaging (κ = 0.818). The intermodality diagnostic agreement was good (κ = 0.704) for observer 1 and moderate (κ = 0.579) for observer 2, respectively. High-resolution MR imaging may be an imaging method comparable with DSA for the characterization and diagnosis of various intracranial artery diseases. © 2016 by American Journal of Neuroradiology.
Digital mammography: more microcalcifications, more columnar cell lesions without atypia.
Verschuur-Maes, Anoek H J; van Gils, Carla H; van den Bosch, Maurice A A J; De Bruin, Peter C; van Diest, Paul J
2011-09-01
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55 159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the mammographic indication for core needle biopsies (density, microcalcifications, or both) and the proportion of columnar cell lesions with or without atypia. The columnar cell lesions were graded according to Schnitt, and we included atypical ductal hyperplasia arising in the context of columnar cell lesions. Proportions were compared using χ(2) tests and prevalence ratios were adjusted for age and hospital. We found that more core needle biopsies per mammogram were taken in the full-field digital mammography period (7.6%) compared with the screen-filmed mammography period (5.0%, P<0.0001). Microcalcifications were more often diagnosed with full-field digital mammography than with screen-filmed mammography (adjusted prevalence ratio: 1.14, confidence interval 95%: 1.01-1.28). Core needle biopsies from the full-field digital mammography era showed more columnar cell lesions (10.8%) than those from the screen-filmed mammography era (4.9%; adjusted prevalence ratio: 1.93, confidence interval 95%: 1.48-2.51), particularly due to more columnar cell lesions without atypia (8.2% respectively 2.8%) while the proportion of columnar cell lesions with atypia remained nearly constant (2.0 vs 2.6%). In conclusion, since the implementation of full-field digital mammography, more microcalcifications are seen at mammography, more often resulting in core needle biopsies, which especially yields more columnar cell lesions without atypia.
Larsson, Laura S
2015-04-01
I tested a social marketing intervention delivered in health department waiting rooms via digital signage technology for increasing radon program participation among priority groups. I conducted a tri-county, community-based study over a 3-year period (2010-2013) in a high-radon state by using a quasi-experimental design. We collected survey data for eligible participants at the time of radon test kit purchase. Radon program participation increased at the intervention site (t38 = 3.74; P = .001; 95% confidence interval [CI] = 4.8, 16.0) with an increase in renters (χ(2)1,228 = 4.3; P = .039), Special Supplementary Nutrition Program for Women, Infants, and Children families (χ(2)1,166 = 3.13; P = .077) and first-time testers (χ(2)1,228 = 10.93; P = .001). Approximately one third (30.3%; n = 30) attributed participation in the radon program to viewing the intervention message. The intervention crossover was also successful with increased monthly kit sales (t37 = 2.69; P = .01; 95% CI = 1.20, 8.47) and increased households participating (t23 = 4.76; P < .001; 95% CI = 3.10, 7.88). A social marketing message was an effective population-based intervention for increasing radon program participation. The results prompted policy changes for Montana radon programming and adoption of digital signage technology by 2 health departments.
Hamilton, Lindsay; Franklin, Robin J M; Jeffery, Nick D
2007-09-18
Clinical spinal cord injury in domestic dogs provides a model population in which to test the efficacy of putative therapeutic interventions for human spinal cord injury. To achieve this potential a robust method of functional analysis is required so that statistical comparison of numerical data derived from treated and control animals can be achieved. In this study we describe the use of digital motion capture equipment combined with mathematical analysis to derive a simple quantitative parameter - 'the mean diagonal coupling interval' - to describe coordination between forelimb and hindlimb movement. In normal dogs this parameter is independent of size, conformation, speed of walking or gait pattern. We show here that mean diagonal coupling interval is highly sensitive to alterations in forelimb-hindlimb coordination in dogs that have suffered spinal cord injury, and can be accurately quantified, but is unaffected by orthopaedic perturbations of gait. Mean diagonal coupling interval is an easily derived, highly robust measurement that provides an ideal method to compare the functional effect of therapeutic interventions after spinal cord injury in quadrupeds.
Black, J A; Waggamon, K A
1992-01-01
An isoelectric focusing method using thin-layer agarose gel has been developed for wheat gliadin. Using flat-bed units with a third electrode, up to 72 samples per gel may be analyzed. Advantages over traditional acid polyacrylamide gel electrophoresis methodology include: faster run times, nontoxic media, and greater sample capacity. The method is suitable for fingerprinting or purity testing of wheat varieties. Using digital images captured by a flat-bed scanner, a 4-band reference system using isoelectric points was devised. Software enables separated bands to be assigned pI values based upon reference tracks. Precision of assigned isoelectric points is shown to be on the order of 0.02 pH units. Captured images may be stored in a computer database and compared to unknown patterns to enable an identification. Parameters for a match with a stored pattern may be adjusted for pI interval required for a match, and number of best matches.
Montefinese, Maria; Semenza, Carlo
2018-05-17
It is widely accepted that different number-related tasks, including solving simple addition and subtraction, may induce attentional shifts on the so-called mental number line, which represents larger numbers on the right and smaller numbers on the left. Recently, it has been shown that different number-related tasks also employ spatial attention shifts along with general cognitive processes. Here we investigated for the first time whether number line estimation and complex mental arithmetic recruit a common mechanism in healthy adults. Participants' performance in two-digit mental additions and subtractions using visual stimuli was compared with their performance in a mental bisection task using auditory numerical intervals. Results showed significant correlations between participants' performance in number line bisection and that in two-digit mental arithmetic operations, especially in additions, providing a first proof of a shared cognitive mechanism (or multiple shared cognitive mechanisms) between auditory number bisection and complex mental calculation.
Elliptical storm cell modeling of digital radar data
NASA Technical Reports Server (NTRS)
Altman, F. J.
1972-01-01
A model for spatial distributions of reflectivity in storm cells was fitted to digital radar data. The data were taken with a modified WSR-57 weather radar with 2.6-km resolution. The data consisted of modified B-scan records on magnetic tape of storm cells tracked at 0 deg elevation for several hours. The MIT L-band radar with 0.8-km resolution produced cross-section data on several cells at 1/2 deg elevation intervals. The model developed uses ellipses for contours of constant effective-reflectivity factor Z with constant orientation and eccentricity within a horizontal cell cross section at a given time and elevation. The centers of the ellipses are assumed to be uniformly spaced on a straight line, with areas linearly related to log Z. All cross sections are similar at different heights (except for cell tops, bottoms, and splitting cells), especially for the highest reflectivities; wind shear causes some translation and rotation between levels. Goodness-of-fit measures and parameters of interest for 204 ellipses are considered.
NASA Technical Reports Server (NTRS)
Benson, Robert F.; Fainberg, Joseph; Osherovich, Vladimir; Truhlik, Vladimir; Wang, Yongli; Arbacher, Becca
2011-01-01
The latest results from an investigation to establish links between solar-wind and topside-ionospheric parameters will be presented including a case where high-latitude topside electron-density Ne(h) profiles indicated dramatic rapid changes in the scale height during the main phase of a large magnetic storm (Dst < -200 nT). These scale-height changes suggest a large heat input to the topside ionosphere at this time. The topside profiles were derived from ISIS-1 digital ionograms obtained from the NASA Space Physics Data Facility (SPDF) Coordinated Data Analysis Web (CDA Web). Solar-wind data obtained from the NASA OMNIWeb database indicated that the magnetic storm was due to a magnetic cloud. This event is one of several large magnetic storms being investigated during the interval from 1965 to 1984 when both solar-wind and digital topside ionograms, from either Alouette-2, ISIS-1, or ISIS-2, are potentially available.
Development of a personal digital assistant-based wireless application in clinical practice.
Chen, Yen-Cheng; Chiu, Hou-Chang; Tsai, Ming-Dar; Chang, Hang; Chong, Chee-Fah
2007-02-01
Our study aims to develop a personal digital assistant (PDA)-based wireless application in medical information processing by using Bluetooth and IEEE 802.11b wireless standards and SyncML codes. In this study, an "integrated database access module" is used to provide a unified integrated access interface while consistency of wireless data transmission is achieved by using the standardized SyncML protocol. A prototype of the system has been developed, implemented, and tested for its mobility, usability, stability, and performance with questionnaire survey. Response time for browsing/searching was usually less than 3s. The average time intervals needed for data transmissions were 68.6+/-8.5s for Bluetooth and 47.0+/-4.8s for 802.11b. The five-point Likert scale (from 1=least to 5=most) questionnaire survey of 30 medical professionals yielded a high degree of satisfaction with the system's mobility (4.18+/-0.89), usability (4.69+/-0.90), stability (3.81+/-0.94), and performance (3.97+/-0.88). The results of our study suggested that PDA applications which exploit wireless communication are convenient and feasible in clinical practice.
Payne, Thomas G.
1982-01-01
REGIONAL MAPPER is a menu-driven system in the BASIC language for computing and plotting (1) time, depth, and average velocity to geologic horizons, (2) interval time, thickness, and interval velocity of stratigraphic intervals, and (3) subcropping and onlapping intervals at unconformities. The system consists of three programs: FILER, TRAVERSER, and PLOTTER. A control point is a shot point with velocity analysis or a shot point at or near a well with velocity check-shot survey. Reflection time to and code number of seismic horizons are filed by digitizing tablet from record sections. TRAVERSER starts at a point of geologic control and, in traversing to another, parallels seismic events, records loss of horizons by onlap and truncation, and stores reflection time for geologic horizons at traversed shot points. TRAVERSER is basically a phantoming procedure. Permafrost thickness and velocity variations, buried canyons with low-velocity fill, and error in seismically derived velocity cause velocity anomalies that complicate depth mapping. Two depths to the top of the pebble is based shale are computed for each control point. One depth, designated Zs on seismically derived velocity. The other (Zw) is based on interval velocity interpolated linearly between wells and multiplied by interval time (isochron) to give interval thickness. Z w is computed for all geologic horizons by downward summation of interval thickness. Unknown true depth (Z) to the pebble shale may be expressed as Z = Zs + es and Z = Zw + ew where the e terms represent error. Equating the two expressions gives the depth difference D = Zs + Zw = ew + es A plot of D for the top of the pebble shale is readily contourable but smoothing is required to produce a reasonably simple surface. Seismically derived velocity used in computing Zs includes the effect of velocity anomalies but is subject to some large randomly distributed errors resulting in depth errors (es). Well-derived velocity used in computing Zw does not include the effect of velocity anomalies, but the error (ew) should reflect these anomalies and should be contourable (non-random). The D surface as contoured with smoothing is assumed to represent ew, that is, the depth effect of variations in permafrost thickness and velocity and buried canyon depth. Estimated depth (Zest) to each geologic horizon is the sum of Z w for that horizon and a constant e w as contoured for the pebble shale, which is the first highly continuous seismic horizon below the zone of anomalous velocity. Results of this 'depthing' procedure are compared with those of Tetra Tech, Inc., the subcontractor responsible for geologic and geophysical interpretation and mapping.
Comparison of the spatial landmark scatter of various 3D digitalization methods.
Boldt, Florian; Weinzierl, Christian; Hertrich, Klaus; Hirschfelder, Ursula
2009-05-01
The aim of this study was to compare four different three-dimensional digitalization methods on the basis of the complex anatomical surface of a cleft lip and palate plaster cast, and to ascertain their accuracy when positioning 3D landmarks. A cleft lip and palate plaster cast was digitalized with the SCAN3D photo-optical scanner, the OPTIX 400S laser-optical scanner, the Somatom Sensation 64 computed tomography system and the MicroScribe MLX 3-axis articulated-arm digitizer. First, four examiners appraised by individual visual inspection the surface detail reproduction of the three non-tactile digitalization methods in comparison to the reference plaster cast. The four examiners then localized the landmarks five times at intervals of 2 weeks. This involved simply copying, or spatially tracing, the landmarks from a reference plaster cast to each model digitally reproduced by each digitalization method. Statistical analysis of the landmark distribution specific to each method was performed based on the 3D coordinates of the positioned landmarks. Visual evaluation of surface detail conformity assigned the photo-optical digitalization method an average score of 1.5, the highest subjectively-determined conformity (surpassing computer tomographic and laser-optical methods). The tactile scanning method revealed the lowest degree of 3D landmark scatter, 0.12 mm, and at 1.01 mm the lowest maximum 3D landmark scatter; this was followed by the computer tomographic, photo-optical and laser-optical methods (in that order). This study demonstrates that the landmarks' precision and reproducibility are determined by the complexity of the reference-model surface as well as the digital surface quality and individual ability of each evaluator to capture 3D spatial relationships. The differences in the 3D-landmark scatter values and lowest maximum 3D-landmark scatter between the best and the worst methods showed minor differences. The measurement results in this study reveal that it is not the method's precision but rather the complexity of the object analysis being planned that should determine which method is ultimately employed.
a New Approach to Physiologic Triggering in Medical Imaging Using Multiple Heart Sounds Alone.
NASA Astrophysics Data System (ADS)
Groch, Mark Walter
A new method for physiological synchronization of medical image acquisition using both the first and second heart sound has been developed. Heart sounds gating (HSG) circuitry has been developed which identifies, individually, both the first (S1) and second (S2) heart sounds from their timing relationship alone, and provides two synchronization points during the cardiac cycle. Identification of first and second heart sounds from their timing relationship alone and application to medical imaging has, heretofore, not been performed in radiology or nuclear medicine. The heart sounds are obtained as conditioned analog signals from a piezoelectric transducer microphone placed on the patient's chest. The timing relationships between the S1 to S2 pulses and the S2 to S1 pulses are determined using a logic scheme capable of distinguishing the S1 and S2 pulses from the heart sounds themselves, using their timing relationships, and the assumption that initially the S1-S2 interval will be shorter than the S2-S1 interval. Digital logic circuitry is utilized to continually track the timing intervals and extend the S1/S2 identification to heart rates up to 200 beats per minute (where the S1-S2 interval is not shorter than the S2-S1 interval). Clinically, first heart sound gating may be performed to assess the systolic ejection portion of the cardiac cycle, with S2 gating utilized for reproduction of the diastolic filling portion of the cycle. One application of HSG used for physiologic synchronization is in multigated blood pool (MGBP) imaging in nuclear medicine. Heart sounds gating has been applied to twenty patients who underwent analysis of ventricular function in Nuclear Medicine, and compared to conventional ECG gated MGBP. Left ventricular ejection fractions calculated from MGBP studies using a S1 and a S2 heart sound trigger correlated well with conventional ECG gated acquisitions in patients adequately gated by HSG and ECG. Heart sounds gating provided superior definition of the diastolic filling phase of the cardiac cycle by qualitative assessment of the left ventricular volume time -activity curves. Heart sounds physiological synchronization has potential to be used in other imaging modalities, such as magnetic resonance imaging, where the ECG is distorted due to the electromagnetic environment within the imager.
Land use and land cover digital data from 1:250,000- and 1:100,000- scale maps
,
1990-01-01
The Earth Science Information Centers (ESIC) distribute digital cartographic/geographic data files produced by the U.S. Geological Survey (USGS) as part of the National Mapping Program. The data files are grouped into four basic types. The first type, called a Digital Line Graph (DLG), is line map information in digital form. These data files include information on planimetric base categories, such as transportation, hydrography, and boundaries. The second type, called a Digital Elevation Model (DEM), consists of a sampled array of elevations for ground positions that are usually at regularly spaced intervals. The third type, Land Use and Land Cover digital data, provide information on nine major classes of land use such as urban, agricultural, or forest as well as associated map data such as political units and Federal land ownership. The fourth type, the Geographic Names Information System, provides primary information for known places, features, and areas in the United States identified by a proper name.
Quantitative optical scanning tests of complex microcircuits
NASA Technical Reports Server (NTRS)
Erickson, J. J.
1980-01-01
An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.
Volumetric breast density affects performance of digital screening mammography.
Wanders, Johanna O P; Holland, Katharina; Veldhuis, Wouter B; Mann, Ritse M; Pijnappel, Ruud M; Peeters, Petra H M; van Gils, Carla H; Karssemeijer, Nico
2017-02-01
To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories. Of all the examinations, 21.6% were categorized as density category 1 ('almost entirely fatty') and 41.5, 28.9, and 8.0% as category 2-4 ('extremely dense'), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1-4, respectively (both p-trend < 0.001). The screening sensitivity, calculated as the proportion of screen-detected among the total of screen-detected and interval tumors, was lower in higher density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1-4, respectively (p-trend < 0.001). Volumetric mammographic density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.
Noninvasive Diagnosis of Coronary Artery Disease Using 12-Lead High-Frequency Electrocardiograms
NASA Technical Reports Server (NTRS)
Schlegel, Todd T.; Arenare, Brian
2006-01-01
A noninvasive, sensitive method of diagnosing certain pathological conditions of the human heart involves computational processing of digitized electrocardiographic (ECG) signals acquired from a patient at all 12 conventional ECG electrode positions. In the processing, attention is focused on low-amplitude, high-frequency components of those portions of the ECG signals known in the art as QRS complexes. The unique contribution of this method lies in the utilization of signal features and combinations of signal features from various combinations of electrode positions, not reported previously, that have been found to be helpful in diagnosing coronary artery disease and such related pathological conditions as myocardial ischemia, myocardial infarction, and congestive heart failure. The electronic hardware and software used to acquire the QRS complexes and perform some preliminary analyses of their high-frequency components were summarized in Real-Time, High-Frequency QRS Electrocardiograph (MSC- 23154), NASA Tech Briefs, Vol. 27, No. 7 (July 2003), pp. 26-28. To recapitulate, signals from standard electrocardiograph electrodes are preamplified, then digitized at a sampling rate of 1,000 Hz, then analyzed by the software that detects R waves and QRS complexes and analyzes them from several perspectives. The software includes provisions for averaging signals over multiple beats and for special-purpose nonrecursive digital filters with specific low- and high-frequency cutoffs. These filters, applied to the averaged signal, effect a band-pass operation in the frequency range from 150 to 250 Hz. The output of the bandpass filter is the desired high-frequency QRS signal. Further processing is then performed in real time to obtain the beat-to-beat root mean square (RMS) voltage amplitude of the filtered signal, certain variations of the RMS voltage, and such standard measures as the heart rate and R-R interval at any given time. A key signal feature analyzed in the present method is the presence versus the absence of reduced-amplitude zones (RAZs). In terms that must be simplified for the sake of brevity, an RAZ comprises several cycles of a high-frequency QRS signal during which the amplitude of the high-frequency oscillation in a portion of the signal is abnormally low (see figure). A given signal sample exhibiting an interval of reduced amplitude may or may not be classified as an RAZ, depending on quantitative criteria regarding peaks and troughs within the reduced-amplitude portion of the high-frequency QRS signal. This analysis is performed in all 12 leads in real time.
Palmisano, Maria; Wu, Anfan; Assaf, Mahmoud; Liu, Liangang; Park, C. Hyung; Savant, Ishani; Liu, Yong; Zhou, Simon
2016-01-01
Objective: This study was conducted to evaluate the effect of apremilast and its major metabolites on the placebo-corrected change-from-baseline QTc interval of an electrocardiogram (ECG). Materials and methods: Healthy male subjects received each of 4 treatments in a randomized, crossover manner. In the 2 active treatment periods, apremilast 30 mg (therapeutic exposure) or 50 mg (supratherapeutic exposure) was administered twice daily for 9 doses. A placebo control was used to ensure double-blind treatment of apremilast, and an open-label, single dose of moxifloxacin 400 mg was administered as a positive control. ECGs were measured using 24-hour digital Holter monitoring. Results: The two-sided 98% confidence intervals (CIs) for ΔΔQTcI of moxifloxacin completely exceeded 5 ms 2 – 4 hours postdose. For both apremilast dose studies, the least-squares mean ΔΔQTcI was < 1 ms at all time points, and the upper limit of two-sided 90% CIs was < 10 ms. There were no QT/QTc values > 480 ms or a change from baseline > 60 ms. Exploratory evaluation of pharmacokinetic/pharmacodynamic data showed no trend between the changes in QT/QTc interval and the concentration of apremilast or its major metabolites M12 and M14. Conclusions: Apremilast did not prolong the QT interval and appears to be safe and well tolerated up to doses of 50 mg twice daily. PMID:27285466
The Effect of Pixel Size on the Accuracy of Orthophoto Production
NASA Astrophysics Data System (ADS)
Kulur, S.; Yildiz, F.; Selcuk, O.; Yildiz, M. A.
2016-06-01
In our country, orthophoto products are used by the public and private sectors for engineering services and infrastructure projects, Orthophotos are particularly preferred due to faster and are more economical production according to vector digital photogrammetric production. Today, digital orthophotos provide an expected accuracy for engineering and infrastructure projects. In this study, the accuracy of orthophotos using pixel sizes with different sampling intervals are tested for the expectations of engineering and infrastructure projects.
Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter
2018-05-14
Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer-reviewed journals. NCT03377036; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Finley, Jason R.; Brewer, William F.; Benjamin, Aaron S.
2011-01-01
Emerging “life-logging” technologies have tremendous potential to augment human autobiographical memory by recording and processing vast amounts of information from an individual’s experiences. In this experiment undergraduate participants wore a SenseCam, a small, sensor-equipped digital camera, as they went about their normal daily activities for five consecutive days. Pictures were captured either at fixed intervals or as triggered by SenseCam’s sensors. On two of five nights, participants watched an end-of-day review of a random subset of pictures captured that day. Participants were tested with a variety of memory measures at intervals of 1, 3, and 8 weeks. The most fruitful of six measures were recognition rating (on a 1–7 scale) and picture-cued recall length. On these tests, end-of-day review enhanced performance relative to no review, while pictures triggered by SenseCam’s sensors showed little difference in performance compared to those taken at fixed time intervals. We discuss the promise of SenseCam as a tool for research and for improving autobiographical memory. PMID:21229457
Significance of postshunt ventricular asymmetries.
Linder, M; Diehl, J T; Sklar, F H
1981-08-01
Ventricular asymmetries after shunt surgery were studied. Right and left ventricular areas from pre-and postoperative computerized tomography scans were measured with a computer digitizing technique, and the respective areas were expressed as a ratio. Measurements were made from the scans of 15 hydrocephalic children selected at random. Ages at surgery ranged from 1 to 101 weeks. The results indicate a significantly greater decrease in ventricular size on the side of the ventricular shunt catheter. Multiple regression analysis showed no relationship between the magnitude of change in ventricular size and either the patients' age orn the time intervals between surgery and follow-up scans. Possible mechanisms for these postshunt ventricular asymmetries are discussed.
NASA Technical Reports Server (NTRS)
Robertson, F. R.
1984-01-01
The role of cloud related diabatic processes in maintaining the structure of the South Pacific Convergence Zone is discussed. The method chosen to evaluate the condensational heating is a diagnostic cumulus mass flux technique which uses GOES digital IR data to characterize the cloud population. This method requires as input an estimate of time/area mean rainfall rate over the area in question. Since direct observation of rainfall in the South Pacific is not feasible, a technique using GOES IR data is being developed to estimate rainfall amounts for a 2.5 degree grid at 12h intervals.
NASA Technical Reports Server (NTRS)
Quilligan, Gerard; DeMonthier, Jeffrey; Suarez, George
2011-01-01
This innovation addresses challenges in lidar imaging, particularly with the detection scheme and the shapes of the detected signals. Ideally, the echoed pulse widths should be extremely narrow to resolve fine detail at high event rates. However, narrow pulses require wideband detection circuitry with increased power dissipation to minimize thermal noise. Filtering is also required to shape each received signal into a form suitable for processing by a constant fraction discriminator (CFD) followed by a time-to-digital converter (TDC). As the intervals between the echoes decrease, the finite bandwidth of the shaping circuits blends the pulses into an analog signal (luminance) with multiple modes, reducing the ability of the CFD to discriminate individual events
NASA Astrophysics Data System (ADS)
Aspinall, M. D.; Joyce, M. J.; Mackin, R. O.; Jarrah, Z.; Boston, A. J.; Nolan, P. J.; Peyton, A. J.; Hawkes, N. P.
2009-01-01
A unique, digital time pick-off method, known as sample-interpolation timing (SIT) is described. This method demonstrates the possibility of improved timing resolution for the digital measurement of time of flight compared with digital replica-analogue time pick-off methods for signals sampled at relatively low rates. Three analogue timing methods have been replicated in the digital domain (leading-edge, crossover and constant-fraction timing) for pulse data sampled at 8 GSa s-1. Events arising from the 7Li(p, n)7Be reaction have been detected with an EJ-301 organic liquid scintillator and recorded with a fast digital sampling oscilloscope. Sample-interpolation timing was developed solely for the digital domain and thus performs more efficiently on digital signals compared with analogue time pick-off methods replicated digitally, especially for fast signals that are sampled at rates that current affordable and portable devices can achieve. Sample interpolation can be applied to any analogue timing method replicated digitally and thus also has the potential to exploit the generic capabilities of analogue techniques with the benefits of operating in the digital domain. A threshold in sampling rate with respect to the signal pulse width is observed beyond which further improvements in timing resolution are not attained. This advance is relevant to many applications in which time-of-flight measurement is essential.
Prediction of time to delivery by transperineal ultrasound in second stage of labor.
Yonetani, N; Yamamoto, R; Murata, M; Nakajima, E; Taguchi, T; Ishii, K; Mitsuda, N
2017-02-01
To investigate whether the transperineal sonographic (TPS) parameters angle of progression (AoP) and midline angle (MLA) can predict the time remaining in the second stage of labor. We evaluated prospectively women with a singleton pregnancy in cephalic presentation at term between October 2013 and September 2014. TPS volumes were obtained immediately after confirmation by digital vaginal examination of a fully dilated cervix. AoP and MLA were measured offline by analyzing the ultrasound volumes. Progression of labor was evaluated every hour during the second stage. The associations of AoP and MLA with the interval between TPS assessment and delivery were evaluated using multivariable Cox proportional hazards analyses in nulliparous and parous women separately. A total of 557 women were evaluated. An AoP ≥ 160° (adjusted hazard ratio (aHR), 2.52 (95% CI, 1.98-3.19)) and MLA ≤ 10° (aHR, 1.79 (95% CI, 1.35-2.34)) in nulliparous women and an AoP ≥ 150° (aHR, 1.86 (95% CI, 1.34-2.57)) and MLA ≤ 20° (aHR, 1.69 (95% CI, 1.21-2.34)) in parous women were significantly associated with the remaining time in labor. The positive/negative likelihood ratios of AoP, MLA, clinical station (fetal head descent as observed by digital examination) and clinical rotation (fetal head rotation as observed by digital examination) at these cut-off points were 3.6/0.6, 2.0/0.6, 1.6/0.6 and 1.6/0.8, respectively, in nulliparous women, and 2.4/0.6, 1.3/0.7, 7.6/0.5 and 5.2/0.7, respectively, in parous women. TPS assessment of AoP and MLA in the second stage of labor was useful for predicting the time remaining in labor and had higher predictive value than did digital vaginal examination in nulliparous women. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
On the New Concept of the Available Water Climatology and Its Application
NASA Astrophysics Data System (ADS)
Byun, H. R.; Kim, D. W.; Choi, K. S.; Deo, R. C.; Lee, S. M.; Park, C. K.; Kwon, S. H.; Kim, G. B.; Kwon, H. N.
2014-12-01
We propose a new concept of climatology called the Available Water Climate (AWC). Available water is 'the remained water usable in every moment' that is calculated regardless of any time intervals or the amounts of precipitation. With this concept, the Available Water Resources Index (AWRI) has been digitized following the earlier work of Byun and Lee (2002). The applicability of AWRI not only to the assessment and prediction of water related disasters but also to the academic researches has been tested. Resulted merits are as follows. Firstly, the threshold value of AWRI for the occurrence of all water related disasters like flood, drought, inundation landslide, and drought each region became clear, therefore the assessment and the prediction of them became much more precise than before. It became clear that the more extreme the AWRI value is, the severer the related disasters become. As example, all disasters caused by heavy rains, even though a small inundation, became predictable at the time step of heavy rain warning with the help of the Long-term remained water index(LWI). As another example, the drought intensity and its dates on start and end are defined with more reasonably and precisely than any other drought indexes with help of the Effective drought index (EDI) using sliding time scale. Secondly, the spatiotemporal distribution of water environment were digitized clearly and objectively using AWRI and new concepts of the Water Abundant Season (WAS) and the Little Water Season (LIWAS), their dates on start and end, and their strength were defined, which is very beneficial for agriculture, forestry, and all other water controls. Also, the differences of water environments among regions were clearly digitized and the improvement of the climate classification by Köppen etc. became possible. Thirdly, other merits will be found continuously afterwards.
A generic sun-tracking algorithm for on-axis solar collector in mobile platforms
NASA Astrophysics Data System (ADS)
Lai, An-Chow; Chong, Kok-Keong; Lim, Boon-Han; Ho, Ming-Cheng; Yap, See-Hao; Heng, Chun-Kit; Lee, Jer-Vui; King, Yeong-Jin
2015-04-01
This paper proposes a novel dynamic sun-tracking algorithm which allows accurate tracking of the sun for both non-concentrated and concentrated photovoltaic systems located on mobile platforms to maximize solar energy extraction. The proposed algorithm takes not only the date, time, and geographical information, but also the dynamic changes of coordinates of the mobile platforms into account to calculate the sun position angle relative to ideal azimuth-elevation axes in real time using general sun-tracking formulas derived by Chong and Wong. The algorithm acquires data from open-loop sensors, i.e. global position system (GPS) and digital compass, which are readily available in many off-the-shelf portable gadgets, such as smart phone, to instantly capture the dynamic changes of coordinates of mobile platforms. Our experiments found that a highly accurate GPS is not necessary as the coordinate changes of practical mobile platforms are not fast enough to produce significant differences in the calculation of the incident angle. On the contrary, it is critical to accurately identify the quadrant and angle where the mobile platforms are moving toward in real time, which can be resolved by using digital compass. In our implementation, a noise filtering mechanism is found necessary to remove unexpected spikes in the readings of the digital compass to ensure stability in motor actuations and effectiveness in continuous tracking. Filtering mechanisms being studied include simple moving average and linear regression; the results showed that a compound function of simple moving average and linear regression produces a better outcome. Meanwhile, we found that a sampling interval is useful to avoid excessive motor actuations and power consumption while not sacrificing the accuracy of sun-tracking.
Ribéreau-Gayon, Agathe; Rando, Carolyn; Morgan, Ruth M; Carter, David O
2018-05-01
In the context of increased scrutiny of the methods in forensic sciences, it is essential to ensure that the approaches used in forensic taphonomy to measure decomposition and estimate the postmortem interval are underpinned by robust evidence-based data. Digital photographs are an important source of documentation in forensic taphonomic investigations but the suitability of the current approaches for photographs, rather than real-time remains, is poorly studied which can undermine accurate forensic conclusions. The present study aimed to investigate the suitability of 2D colour digital photographs for evaluating decomposition of exposed human analogues (Sus scrofa domesticus) in a tropical savanna environment (Hawaii), using two published scoring methods; Megyesi et al., 2005 and Keough et al., 2017. It was found that there were significant differences between the real-time and photograph decomposition scores when the Megyesi et al. method was used. However, the Keough et al. method applied to photographs reflected real-time decomposition more closely and thus appears more suitable to evaluate pig decomposition from 2D photographs. The findings indicate that the type of scoring method used has a significant impact on the ability to accurately evaluate the decomposition of exposed pig carcasses from photographs. It was further identified that photographic taphonomic analysis can reach high inter-observer reproducibility. These novel findings are of significant importance for the forensic sciences as they highlight the potential for high quality photograph coverage to provide useful complementary information for the forensic taphonomic investigation. New recommendations to develop robust transparent approaches adapted to photographs in forensic taphonomy are suggested based on these findings. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Change in area of geographic atrophy in the Age-Related Eye Disease Study: AREDS report number 26.
Lindblad, Anne S; Lloyd, Patricia C; Clemons, Traci E; Gensler, Gary R; Ferris, Frederick L; Klein, Michael L; Armstrong, Jane R
2009-09-01
To characterize progression of geographic atrophy (GA) associated with age-related macular degeneration in AREDS as measured by digitized fundus photographs. Fundus photographs from 181 of 4757 AREDS participants with a GA area of at least 0.5 disc areas at baseline or from participants who developed bilateral GA during follow-up were scanned, digitized, and evaluated longitudinally. Geographic atrophy area was determined using planimetry. Rates of progression from noncentral to central GA and of vision loss following development of central GA included the entire AREDS cohort. Median initial lesion size was 4.3 mm(2). Average change in digital area of GA from baseline was 2.03 mm(2) (standard error of the mean, 0.24 mm(2)) at 1 year, 3.78 mm(2) (0.24 mm(2)) at 2 years, 5.93 mm(2) (0.34 mm(2)) at 3 years, and 1.78 mm(2) (0.086 mm(2)) per year overall. Median time to developing central GA after any GA diagnosis was 2.5 years (95% confidence interval, 2.0-3.0). Average visual acuity decreased by 3.7 letters at first documentation of central GA, and by 22 letters at year 5. Growth of GA area can be reliably measured using standard fundus photographs that are digitized and subsequently graded at a reading center. Development of GA is associated with subsequent further growth of GA, development of central GA, and loss in central vision.
TOT measurement implemented in FPGA TDC
NASA Astrophysics Data System (ADS)
Fan, Huan-Huan; Cao, Ping; Liu, Shu-Bin; An, Qi
2015-11-01
Time measurement plays a crucial role for the purpose of particle identification in high energy physics experiments. With increasingly demanding physics goals and the development of electronics, modern time measurement systems need to meet the requirement of excellent resolution specification as well as high integrity. Based on Field Programmable Gate Arrays (FPGAs), FPGA time-to-digital converters (TDCs) have become one of the most mature and prominent time measurement methods in recent years. For correcting the time-walk effect caused by leading timing, a time-over-threshold (TOT) measurement should be added to the FPGA TDC. TOT can be obtained by measuring the interval between the signal leading and trailing edges. Unfortunately, a traditional TDC can recognize only one kind of signal edge, the leading or the trailing. Generally, to measure the interval, two TDC channels need to be used at the same time, one for leading, the other for trailing. However, this method unavoidably increases the amount of FPGA resources used and reduces the TDC's integrity. This paper presents one method of TOT measurement implemented in a Xilinx Virtex-5 FPGA. In this method, TOT measurement can be achieved using only one TDC input channel. The consumed resources and time resolution can both be guaranteed. Testing shows that this TDC can achieve resolution better than 15ps for leading edge measurement and 37 ps for TOT measurement. Furthermore, the TDC measurement dead time is about two clock cycles, which makes it good for applications with higher physics event rates. Supported by National Natural Science Foundation of China (11079003, 10979003)
Huang, Sha; Deshpande, Aadya; Yeo, Sing-Chen; Lo, June C; Chee, Michael W L; Gooley, Joshua J
2016-09-01
The ability to recall facts is improved when learning takes place at spaced intervals, or when sleep follows shortly after learning. However, many students cram for exams and trade sleep for other activities. The aim of this study was to examine the interaction of study spacing and time in bed (TIB) for sleep on vocabulary learning in adolescents. In the Need for Sleep Study, which used a parallel-group design, 56 adolescents aged 15-19 years were randomly assigned to a week of either 5 h or 9 h of TIB for sleep each night as part of a 14-day protocol conducted at a boarding school. During the sleep manipulation period, participants studied 40 Graduate Record Examination (GRE)-type English words using digital flashcards. Word pairs were presented over 4 consecutive days (spaced items), or all at once during single study sessions (massed items), with total study time kept constant across conditions. Recall performance was examined 0 h, 24 h, and 120 h after all items were studied. For all retention intervals examined, recall of massed items was impaired by a greater amount in adolescents exposed to sleep restriction. In contrast, cued recall performance on spaced items was similar between sleep groups. Spaced learning conferred strong protection against the effects of sleep restriction on recall performance, whereas students who had insufficient sleep were more likely to forget items studied over short time intervals. These findings in adolescents demonstrate the importance of combining good study habits and good sleep habits to optimize learning outcomes. © 2016 Associated Professional Sleep Societies, LLC.
Embedded programmable blood pressure monitoring system
NASA Astrophysics Data System (ADS)
Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk
2010-02-01
A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.
Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)
NASA Technical Reports Server (NTRS)
Lu, L.; Lyon, R. J. P.
1971-01-01
The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.
Digital Signal Processing For Low Bit Rate TV Image Codecs
NASA Astrophysics Data System (ADS)
Rao, K. R.
1987-06-01
In view of the 56 KBPS digital switched network services and the ISDN, low bit rate codecs for providing real time full motion color video are under various stages of development. Some companies have already brought the codecs into the market. They are being used by industry and some Federal Agencies for video teleconferencing. In general, these codecs have various features such as multiplexing audio and data, high resolution graphics, encryption, error detection and correction, self diagnostics, freezeframe, split video, text overlay etc. To transmit the original color video on a 56 KBPS network requires bit rate reduction of the order of 1400:1. Such a large scale bandwidth compression can be realized only by implementing a number of sophisticated,digital signal processing techniques. This paper provides an overview of such techniques and outlines the newer concepts that are being investigated. Before resorting to the data compression techniques, various preprocessing operations such as noise filtering, composite-component transformation and horizontal and vertical blanking interval removal are to be implemented. Invariably spatio-temporal subsampling is achieved by appropriate filtering. Transform and/or prediction coupled with motion estimation and strengthened by adaptive features are some of the tools in the arsenal of the data reduction methods. Other essential blocks in the system are quantizer, bit allocation, buffer, multiplexer, channel coding etc.
Effects of integration time on in-water radiometric profiles.
D'Alimonte, Davide; Zibordi, Giuseppe; Kajiyama, Tamito
2018-03-05
This work investigates the effects of integration time on in-water downward irradiance E d , upward irradiance E u and upwelling radiance L u profile data acquired with free-fall hyperspectral systems. Analyzed quantities are the subsurface value and the diffuse attenuation coefficient derived by applying linear and non-linear regression schemes. Case studies include oligotrophic waters (Case-1), as well as waters dominated by Colored Dissolved Organic Matter (CDOM) and Non-Algal Particles (NAP). Assuming a 24-bit digitization, measurements resulting from the accumulation of photons over integration times varying between 8 and 2048ms are evaluated at depths corresponding to: 1) the beginning of each integration interval (Fst); 2) the end of each integration interval (Lst); 3) the averages of Fst and Lst values (Avg); and finally 4) the values weighted accounting for the diffuse attenuation coefficient of water (Wgt). Statistical figures show that the effects of integration time can bias results well above 5% as a function of the depth definition. Results indicate the validity of the Wgt depth definition and the fair applicability of the Avg one. Instead, both the Fst and Lst depths should not be adopted since they may introduce pronounced biases in E u and L u regression products for highly absorbing waters. Finally, the study reconfirms the relevance of combining multiple radiometric casts into a single profile to increase precision of regression products.
NASA Astrophysics Data System (ADS)
Zhao, Yun-wei; Zhu, Zi-qiang; Lu, Guang-yin; Han, Bo
2018-03-01
The sine and cosine transforms implemented with digital filters have been used in the Transient electromagnetic methods for a few decades. Kong (2007) proposed a method of obtaining filter coefficients, which are computed in the sample domain by Hankel transform pair. However, the curve shape of Hankel transform pair changes with a parameter, which usually is set to be 1 or 3 in the process of obtaining the digital filter coefficients of sine and cosine transforms. First, this study investigates the influence of the parameter on the digital filter algorithm of sine and cosine transforms based on the digital filter algorithm of Hankel transform and the relationship between the sine, cosine function and the ±1/2 order Bessel function of the first kind. The results show that the selection of the parameter highly influences the precision of digital filter algorithm. Second, upon the optimal selection of the parameter, it is found that an optimal sampling interval s also exists to achieve the best precision of digital filter algorithm. Finally, this study proposes four groups of sine and cosine transform digital filter coefficients with different length, which may help to develop the digital filter algorithm of sine and cosine transforms, and promote its application.
NASA Astrophysics Data System (ADS)
Nakanishi, Hideya; Imazu, Setsuo; Ohsuna, Masaki; Kojima, Mamoru; Nonomura, Miki; Shoji, Mamoru; Emoto, Masahiko; Yoshida, Masanobu; Iwata, Chie; Miyake, Hitoshi; Nagayama, Yoshio; Kawahata, Kazuo
To deal with endless data streams acquired in LHD steady-state experiments, the LHD data acquisition system was designed with a simple concept that divides a long pulse into a consecutive series of 10-s “subshots”. Latest digitizers applying high-speed PCI-Express technology, however, output nonstop gigabyte per second data streams whose subshot intervals would be extremely long if 10-s rule was applied. These digitizers need shorter subshot intervals, less than 10-s long. In contrast, steady-state fusion plants need uninterrupted monitoring of the environment and device soundness. They adopt longer subshot lengths of either 10 min or 1 day. To cope with both uninterrupted monitoring and ultra-fast diagnostics, the ability to vary the subshot length according to the type of operation is required. In this study, a design modification that enables variable subshot lengths was implemented and its practical effectiveness in LHD was verified.
Nordstrom, M A; Mapletoft, E A; Miles, T S
1995-11-01
A solution is described for the acquisition on a personal computer of standard pulses derived from neuronal discharge, measurement of neuronal discharge times, real-time control of stimulus delivery based on specified inter-pulse interval conditions in the neuronal spike train, and on-line display and analysis of the experimental data. The hardware consisted of an Apple Macintosh IIci computer and a plug-in card (National Instruments NB-MIO16) that supports A/D, D/A, digital I/O and timer functions. The software was written in the object-oriented graphical programming language LabView. Essential elements of the source code of the LabView program are presented and explained. The use of the system is demonstrated in an experiment in which the reflex responses to muscle stretch are assessed for a single motor unit in the human masseter muscle.
Discrete time learning control in nonlinear systems
NASA Technical Reports Server (NTRS)
Longman, Richard W.; Chang, Chi-Kuang; Phan, Minh
1992-01-01
In this paper digital learning control methods are developed primarily for use in single-input, single-output nonlinear dynamic systems. Conditions for convergence of the basic form of learning control based on integral control concepts are given, and shown to be satisfied by a large class of nonlinear problems. It is shown that it is not the gross nonlinearities of the differential equations that matter in the convergence, but rather the much smaller nonlinearities that can manifest themselves during the short time interval of one sample time. New algorithms are developed that eliminate restrictions on the size of the learning gain, and on knowledge of the appropriate sign of the learning gain, for convergence to zero error in tracking a feasible desired output trajectory. It is shown that one of the new algorithms can give guaranteed convergence in the presence of actuator saturation constraints, and indicate when the requested trajectory is beyond the actuator capabilities.
NASA Technical Reports Server (NTRS)
Bechtel, R. D.; Mateos, M. A.; Lincoln, K. A.
1988-01-01
Briefly described are the essential features of a computer program designed to interface a personal computer with the fast, digital data acquisition system of a time-of-flight mass spectrometer. The instrumentation was developed to provide a time-resolved analysis of individual vapor pulses produced by the incidence of a pulsed laser beam on an ablative material. The high repetition rate spectrometer coupled to a fast transient recorder captures complete mass spectra every 20 to 35 microsecs, thereby providing the time resolution needed for the study of this sort of transient event. The program enables the computer to record the large amount of data generated by the system in short time intervals, and it provides the operator the immediate option of presenting the spectral data in several different formats. Furthermore, the system does this with a high degree of automation, including the tasks of mass labeling the spectra and logging pertinent instrumental parameters.
NASA Astrophysics Data System (ADS)
Wang, Yonggang; Liu, Chong
2015-10-01
Because large nonlinearity errors exist in the current tapped-delay line (TDL) style field programmable gate array (FPGA)-based time-to-digital converters (TDC), bin-by-bin calibration techniques have to be resorted for gaining a high measurement resolution. If the TDL in selected FPGAs is significantly affected by changes in ambient temperature, the bin-by-bin calibration table has to be updated as frequently as possible. The on-line calibration and calibration table updating increase the TDC design complexity and limit the system performance to some extent. This paper proposes a method to minimize the nonlinearity errors of TDC bins, so that the bin-by-bin calibration may not be needed while maintaining a reasonably high time resolution. The method is a two pass approach: By a bin realignment, the large number of wasted zero-width bins in the original TDL is reused and the granularity of the bins is improved; by a bin decimation, the bin size and its uniformity is traded-off, and the time interpolation by the delay line turns more precise so that the bin-by-bin calibration is not necessary. Using Xilinx 28 nm FPGAs, in which the TDL property is not very sensitive to ambient temperature, the proposed TDC achieves approximately 15 ps root-mean-square (RMS) time resolution by dual-channel measurements of time-intervals over the range of operating temperature. Because of removing the calibration and less logic resources required for the data post-processing, the method has bigger multi-channel capability.
A Method For Simultaneous Registration Of Motion And Electromyography During Walking
NASA Astrophysics Data System (ADS)
Giith, V.; Abbink, F.; Heinrichs, W.; Theysohn, H.
1980-07-01
The points the movements of which are to be registered are marked by little light sensitive photoamplifiers. These are periodically (50 times per second) exposed to a VÖshaped bright figure projected by a rotating mirror. The pattern of the resulting electrical impulses is analysed by a computer controlled fast digital time counting apparatus with a clock of 100 ns. Is this way we get every 20 ms the respective position of the marked points (up to nine). The results of this method are simular to the well known photographic chronocyclography with the advantage, however, that the momentary positions of the points are calculated on line (accuracy ± 2 mm). In the intervals between the sweeps of the light-figure the computer picks up 8 lines of analogue data, actually the electromyogram of eight different muscles, and stores them, together with the optical data on digital magnetic tape for further evaluation. After the investigation the obtained data are analysed in the following way : 1) Plotting several parameters of positions (angles, c.g.) together with the electromyogram ver-sus time during one step of walking. 2) Calculating the correlation between the patterns of electrical activity of different muscles. 3) Comparison of the results of 1) and 2) between healthy persons and handicapped persons (C.P.), scoliosis, desease of spine, hip and pelvis, etc...).
Operation of U.S. Geological Survey unmanned digital magnetic observatories
Wilson, L.R.
1990-01-01
The precision and continuity of data recorded by unmanned digital magnetic observatories depend on the type of data acquisition equipment used and operating procedures employed. Three generations of observatory systems used by the U.S. Geological Survey are described. A table listing the frequency of component failures in the current observatory system has been compiled for a 54-month period of operation. The cause of component failure was generally mechanical or due to lightning. The average percentage data loss per month for 13 observatories operating a combined total of 637 months was 9%. Frequency distributions of data loss intervals show the highest frequency of occurrence to be intervals of less than 1 h. Installation of the third generation system will begin in 1988. The configuration of the third generation observatory system will eliminate most of the mechanical problems, and its components should be less susceptible to lightning. A quasi-absolute coil-proton system will be added to obtain baseline control for component variation data twice daily. Observatory data, diagnostics, and magnetic activity indices will be collected at 12-min intervals via satellite at Golden, Colorado. An improvement in the quality and continuity of data obtained with the new system is expected. ?? 1990.
Chen, Lin Y; Lopez, Faye L; Gottesman, Rebecca F; Huxley, Rachel R; Agarwal, Sunil K; Loehr, Laura; Mosley, Thomas; Alonso, Alvaro
2014-09-01
The mechanism underlying the association of atrial fibrillation (AF) with cognitive decline in stroke-free individuals is unclear. We examined the association of incident AF with cognitive decline in stroke-free individuals, stratified by subclinical cerebral infarcts (SCIs) on brain MRI scans. We analyzed data from 935 stroke-free participants (mean age±SD, 61.5±4.3 years; 62% women; and 51% black) from 1993 to 1995 through 2004 to 2006 in the Atherosclerosis Risk in Communities Study, a biracial community-based prospective cohort study. Cognitive testing (including the digit symbol substitution and the word fluency tests) was performed in 1993 to 1995, 1996 to 1998, and 2004 to 2006 and brain MRI scans in 1993 to 1995 and 2004 to 2006. During follow-up, there were 48 incident AF events. Incident AF was associated with greater annual average rate of decline in digit symbol substitution (-0.77; 95% confidence interval, -1.55 to 0.01; P=0.054) and word fluency (-0.80; 95% confidence interval, -1.60 to -0.01; P=0.048). Among participants without SCIs on brain MRI scans, incident AF was not associated with cognitive decline. In contrast, incident AF was associated with greater annual average rate of decline in word fluency (-2.65; 95% confidence interval, -4.26 to -1.03; P=0.002) among participants with prevalent SCIs in 1993 to 1995. Among participants who developed SCIs during follow-up, incident AF was associated with a greater annual average rate of decline in digit symbol substitution (-1.51; 95% confidence interval, -3.02 to -0.01; P=0.049). The association of incident AF with cognitive decline in stroke-free individuals can be explained by the presence or development of SCIs, raising the possibility of anticoagulation as a strategy to prevent cognitive decline in AF. © 2014 American Heart Association, Inc.
2015-01-01
Objectives. I tested a social marketing intervention delivered in health department waiting rooms via digital signage technology for increasing radon program participation among priority groups. Methods. I conducted a tri-county, community-based study over a 3-year period (2010–2013) in a high-radon state by using a quasi-experimental design. We collected survey data for eligible participants at the time of radon test kit purchase. Results. Radon program participation increased at the intervention site (t38 = 3.74; P = .001; 95% confidence interval [CI] = 4.8, 16.0) with an increase in renters (χ21,228 = 4.3; P = .039), Special Supplementary Nutrition Program for Women, Infants, and Children families (χ21,166 = 3.13; P = .077) and first-time testers (χ21,228 = 10.93; P = .001). Approximately one third (30.3%; n = 30) attributed participation in the radon program to viewing the intervention message. The intervention crossover was also successful with increased monthly kit sales (t37 = 2.69; P = .01; 95% CI = 1.20, 8.47) and increased households participating (t23 = 4.76; P < .001; 95% CI = 3.10, 7.88). Conclusions. A social marketing message was an effective population-based intervention for increasing radon program participation. The results prompted policy changes for Montana radon programming and adoption of digital signage technology by 2 health departments. PMID:25121816
Mahe, Guillaume; Liedl, David A; McCarter, Charlene; Shepherd, Roger; Gloviczki, Peter; McPhail, Ian R; Rooke, Thom W; Wennberg, Paul W
2014-04-01
This study was conducted to determine the sensitivity and specificity of laser Doppler flowmetry (LDF) measurements for digital obstructive arterial disease (DOAD) using angiography as the reference standard and to compare the accuracy of different classical tests used to assess DOAD. Diagnosis of vascular abnormalities at the digital level is challenging. Angiography is the gold standard for assessment of DOAD but is invasive and expensive to perform. We performed a retrospective analysis of consecutive patients referred at Mayo Clinic (Rochester, Minn) for upper extremity arterial assessment during a 27-month period. Finger-brachial index, skin blood flow (in arbitrary units [a.u.]), and skin temperature (in degrees Celsius) were recorded in each digit on the pulp at baseline and after a thermal challenge test (hand placed in a thermal box at 47.0°C for 15 minutes). Angiogram analysis was blinded and performed by a radiologist using a vascularization scale ranging from 0 (no vessel) to 4 (normal). The receiver operating characteristic curve was used to define a specific cutoff point to detect DOAD. Twenty-two patients had LDF measurements and complete angiograms. A total of 185 digits were analyzed because some patients had only analysis of one hand. The best area under the curve (AUC) was 0.98 (range, 0.94-0.99) for postwarming skin blood flow, with a cutoff point of ≤206 a.u. This AUC was statistically different from AUCs of all the other tests (P < .01). Sensitivity and specificity were 93% (95% confidence interval, 85%-97%) and 96% (95% confidence interval, 90%-99%), respectively. LDF combined with a thermal challenge is highly accurate, safe, and noninvasive means to detect DOAD. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Taubel, Jorg; Naseem, Asif; Harada, Tomohiko; Wang, Duolao; Arezina, Radivoj; Lorch, Ulrike; Camm, A John
2010-01-01
AIMS To characterize the effects of levofloxacin on QT interval in healthy subjects and the most appropriate oral positive control treatments for International Conference on Harmonization (ICH) E14 QT/QTc studies. METHODS Healthy subjects received a single dose of levofloxacin (1000 or 1500 mg), moxifloxacin (400 mg) or placebo in a four-period crossover design. Digital 12-lead ECGs were recorded in triplicate. Measurement of QT interval was performed automatically with subsequent manual onscreen over-reading using electronic callipers. Blood samples were taken for determination of levofloxacin and moxifloxacin concentrations. RESULTS Mean QTcI (QT interval corrected for heart rate using a correction factor that is applicable to each individual) was prolonged in subjects receiving moxifloxacin 400 mg compared with placebo. The largest time-matched difference in QTcI for moxifloxacin compared with placebo was observed to be 13.19 ms (95% confidence interval 11.21, 15.17) at 3.5 h post dose. Prolonged mean QTcI was also observed in subjects receiving levofloxacin 1000 mg and 1500 mg compared with placebo. The largest time-matched difference in QTcI compared with placebo was observed at 3.5 h post dose for both 1000 mg and 1500 mg of levofloxacin [mean (95%) 4.42 ms (2.44, 6.39) in 1000 mg and 7.44 ms (5.47, 9.42) in 1500 mg]. A small increase in heart rate was observed with levofloxacin during the course of the study. However, moxifloxacin showed a greater increase compared with levofloxacin. CONCLUSIONS Both levofloxacin and moxifloxacin can fulfil the criteria for a positive comparator. The ICH E14 guidelines recommend a threshold of around 5 ms for a positive QT/QTc study. The largest time-matched difference in QTc for levofloxacin suggests the potential for use in more rigorous QT/QTc studies. This study has demonstrated the utility of levofloxacin on the assay in measuring mean QTc changes around 5 ms. PMID:20406223
Shen, Feng; Du, Wenbin; Kreutz, Jason E; Fok, Alice; Ismagilov, Rustem F
2010-10-21
This paper describes a SlipChip to perform digital PCR in a very simple and inexpensive format. The fluidic path for introducing the sample combined with the PCR mixture was formed using elongated wells in the two plates of the SlipChip designed to overlap during sample loading. This fluidic path was broken up by simple slipping of the two plates that removed the overlap among wells and brought each well in contact with a reservoir preloaded with oil to generate 1280 reaction compartments (2.6 nL each) simultaneously. After thermal cycling, end-point fluorescence intensity was used to detect the presence of nucleic acid. Digital PCR on the SlipChip was tested quantitatively by using Staphylococcus aureus genomic DNA. As the concentration of the template DNA in the reaction mixture was diluted, the fraction of positive wells decreased as expected from the statistical analysis. No cross-contamination was observed during the experiments. At the extremes of the dynamic range of digital PCR the standard confidence interval determined using a normal approximation of the binomial distribution is not satisfactory. Therefore, statistical analysis based on the score method was used to establish these confidence intervals. The SlipChip provides a simple strategy to count nucleic acids by using PCR. It may find applications in research applications such as single cell analysis, prenatal diagnostics, and point-of-care diagnostics. SlipChip would become valuable for diagnostics, including applications in resource-limited areas after integration with isothermal nucleic acid amplification technologies and visual readout.
Accurate computation of gravitational field of a tesseroid
NASA Astrophysics Data System (ADS)
Fukushima, Toshio
2018-02-01
We developed an accurate method to compute the gravitational field of a tesseroid. The method numerically integrates a surface integral representation of the gravitational potential of the tesseroid by conditionally splitting its line integration intervals and by using the double exponential quadrature rule. Then, it evaluates the gravitational acceleration vector and the gravity gradient tensor by numerically differentiating the numerically integrated potential. The numerical differentiation is conducted by appropriately switching the central and the single-sided second-order difference formulas with a suitable choice of the test argument displacement. If necessary, the new method is extended to the case of a general tesseroid with the variable density profile, the variable surface height functions, and/or the variable intervals in longitude or in latitude. The new method is capable of computing the gravitational field of the tesseroid independently on the location of the evaluation point, namely whether outside, near the surface of, on the surface of, or inside the tesseroid. The achievable precision is 14-15 digits for the potential, 9-11 digits for the acceleration vector, and 6-8 digits for the gradient tensor in the double precision environment. The correct digits are roughly doubled if employing the quadruple precision computation. The new method provides a reliable procedure to compute the topographic gravitational field, especially that near, on, and below the surface. Also, it could potentially serve as a sure reference to complement and elaborate the existing approaches using the Gauss-Legendre quadrature or other standard methods of numerical integration.
Landry, Gregory J; McClary, Ashley; Liem, Timothy K; Mitchell, Erica L; Azarbal, Amir F; Moneta, Gregory L
2013-05-01
Finger amputations are typically performed as distal as possible to preserve maximum finger length. Failure of primary amputation leads to additional procedures, which could potentially be avoided if a more proximal amputation was initially performed. The effect of single versus multiple procedures on morbidity and mortality is not known. We evaluated factors that predicted primary healing and the effects of secondary procedures on survival. Patients undergoing finger amputations from 1995 to 2011 were evaluated for survival with uni- and multivariate analysis of demographic data and preoperative vascular laboratory studies to assess factors influencing primary healing. Seventy-six patients underwent 175 finger amputations (range 1 to 6 fingers per patient). Forty-one percent had diabetes, 33% had nonatherosclerotic digital artery disease, and 29% were on dialysis. Sex distribution was equal. Primary healing occurred in 78.9%, with the remainder requiring revisions. By logistic regression analysis, nonatherosclerotic digital artery disease was associated with failure of primary healing (odds ratio = 7.5; 95% confidence interval, 1.03 to 54; P = .047). Digital photoplethysmography did not predict primary healing. The overall healing of primary and secondary finger amputations was 96.0%. The mean survival after the initial finger amputation was 34.3 months and did not differ between patients undergoing single (35.6 months) versus multiple procedures (33.6 months). Dialysis dependence was associated with decreased survival (hazard ratio = 2.9; 95% confidence interval, 1.13 to 7.25; P = .026). Failure of primary healing is associated with the presence of nonatherosclerotic digital artery disease and is not predicted by digital photoplethysmographic studies. Dialysis dependence is associated with decreased survival in patients with finger amputations, but failure of primary healing does not adversely affect survival. A strategy of aggressive preservation of finger length is appropriate for most patients. Copyright © 2013. Published by Elsevier Inc.
A digital wide range neutron flux measuring system for HL-2A
NASA Astrophysics Data System (ADS)
Yuan, Chen; Wu, Jun; Yin, Zejie
2017-08-01
To achieve wide-range, high-integration, and real-time performance on the neutron flux measurement on the HL-2A tokamak, a digital neutron flux measuring (DNFM) system based on the peripheral component interconnection (PCI) eXtension for Instrumentation express (PXIe) bus was designed. This system comprises a charge-sensitive preamplifier and a field programmable gate array (FPGA)-based main electronics plug-in. The DNFM totally covers source-range and intermediate-range neutron flux measurements, and increases system integration by a large margin through joining the pulse-counting mode and Campbell mode. Meanwhile, the neutron flux estimation method based on pulse piling proportions is able to choose and switch measuring modes in accordance with current flux, and this ensures the accuracy of measurements when the neutron flux changes suddenly. It has been demonstrated by simulated signals that the DNFM enhances the full-scale measuring range up to 1.9 × 108 cm-2 s-1, with relative error below 6.1%. The DNFM has been verified to provide a high temporal sensitivity at 10 ms time intervals on a single fission chamber on HL-2A. Contributed paper, published as part of the Proceedings of the 3rd Domestic Electromagnetic Plasma Diagnostics Workshop, September 2016, Hefei, China.
Visible-Infrared Hyperspectral Image Projector
NASA Technical Reports Server (NTRS)
Bolcar, Matthew
2013-01-01
The VisIR HIP generates spatially-spectrally complex scenes. The generated scenes simulate real-world targets viewed by various remote sensing instruments. The VisIR HIP consists of two subsystems: a spectral engine and a spatial engine. The spectral engine generates spectrally complex uniform illumination that spans the wavelength range between 380 nm and 1,600 nm. The spatial engine generates two-dimensional gray-scale scenes. When combined, the two engines are capable of producing two-dimensional scenes with a unique spectrum at each pixel. The VisIR HIP can be used to calibrate any spectrally sensitive remote-sensing instrument. Tests were conducted on the Wide-field Imaging Interferometer Testbed at NASA s Goddard Space Flight Center. The device is a variation of the calibrated hyperspectral image projector developed by the National Institute of Standards and Technology in Gaithersburg, MD. It uses Gooch & Housego Visible and Infrared OL490 Agile Light Sources to generate arbitrary spectra. The two light sources are coupled to a digital light processing (DLP(TradeMark)) digital mirror device (DMD) that serves as the spatial engine. Scenes are displayed on the DMD synchronously with desired spectrum. Scene/spectrum combinations are displayed in rapid succession, over time intervals that are short compared to the integration time of the system under test.
An automated mapping satellite system ( Mapsat).
Colvocoresses, A.P.
1982-01-01
The favorable environment of space permits a satellite to orbit the Earth with very high stability as long as no local perturbing forces are involved. Solid-state linear-array sensors have no moving parts and create no perturbing force on the satellite. Digital data from highly stabilized stereo linear arrays are amenable to simplified processing to produce both planimetric imagery and elevation data. A satellite imaging system, called Mapsat, including this concept has been proposed to produce data from which automated mapping in near real time can be accomplished. Image maps as large as 1:50 000 scale with contours as close as a 20-m interval may be produced from Mapsat data. -from Author
Development of real-time extensometer based on image processing
NASA Astrophysics Data System (ADS)
Adinanta, H.; Puranto, P.; Suryadi
2017-04-01
An extensometer system was developed by using high definition web camera as main sensor to track object position. The developed system applied digital image processing techniques. The image processing was used to measure the change of object position. The position measurement was done in real-time so that the system can directly showed the actual position in both x and y-axis. In this research, the relation between pixel and object position changes had been characterized. The system was tested by moving the target in a range of 20 cm in interval of 1 mm. To verify the long run performance, the stability and linearity of continuous measurements on both x and y-axis, this measurement had been conducted for 83 hours. The results show that this image processing-based extensometer had both good stability and linearity.
The effects of deanol on cognitive performance and electrophysiology in elderly humans.
Marsh, G R; Linnoila, M
1979-01-01
Deanol (900 mg/day for 21 days) had no effect on learning a list of words when tested at weekly intervals. Tests of simple and complex reaction time and a test of continuous serial decoding of digits showed no enhancement with the drug. Several components of evoked potentials recorded from several scalp sites did show enhanced amplitude under drug treatment. These changes were not accompanied by changes in the EEG spectrum as are seen with some other psychoactive drugs. Deanol seems to be an ineffective treatment for the normal slowing of cognitive function seen in the normal elderly person or those elderly with only minimal cognitive decline and free of symptoms of dementia. Contrary to earlier reports, elderly persons were found to be able to benefit from warning signals in a complex reaction time task.
Meislin, Megan A; Wagner, Eric R; Shin, Alexander Y
2016-04-01
The purpose of this study was to validate elbow flexion and extension measured from smartphone photography obtained by participants and compared them with photographs obtained by surgeons and goniometric measurements. We enrolled 32 participants with a total of 64 elbows, aged 25 to 68 years. Participants obtained smartphone photographs of full elbow flexion and extension. Then surgeons obtained the same photographs and goniometric measurement of elbow range of motion (ROM). We measured ROM from the photographs using Adobe Photoshop and calculated average ROM. Comparisons of manual goniometer versus digital measurements, participant versus surgeon photograph measurements, and interobserver measurements were statistically analyzed. Average ROM measured by manual goniometer and digital photographs was 0° to 129° (range, 0° to 140°) and 0° to 129° (range, 0° to 145°), respectively. The goniometer versus digital measurements interclass correlation was 0.828 (L) and 0.740 (R). Pearson coefficient was 0.845 (L) and 0.757 (R). Bland-Altman plots demonstrated that 30 of 32 digital measurements (L) and 31 of 32 measurements (R) were within the 95% confidence interval. Participant-obtained photographs compared with researcher's photographs interclass correlation was 0.955 (L) and 0.941 (R), with a Pearson coefficient of 0.962 (L) and 0.957 (R), respectively. Reviewing interobserver reliability, concordance coefficients were 0.793 (L) and 0.767 (R) and Pearson coefficients were 0.811 (L) and 0.780 (R). Bland-Altman plots demonstrated that 28 of 32 digital measurements (L) and 26 of 32 measurements (R) were within the 95% confidence interval. Measuring elbow ROM using smartphone digital photography is valid and reliable. Participants were able to obtain accurate photographs and the measurements based on these photographs show no statistical difference from those taken by surgeons or goniometric measurement. This study validates using smartphone photography for measuring elbow ROM by laymen in a remote setting. Diagnostic II. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Fink, Christine; Uhlmann, Lorenz; Klose, Christina; Haenssle, Holger A
2018-05-17
Reliable and accurate assessment of severity in psoriasis is very important in order to meet indication criteria for initiation of systemic treatment or to evaluate treatment efficacy. The most acknowledged tool for measuring the extent of psoriatic skin changes is the Psoriasis Area and Severity Index (PASI). However, the calculation of PASI can be tedious and subjective and high intraobserver and interobserver variability is an important concern. Therefore, there is a great need for a standardised and objective method that guarantees a reproducible PASI calculation. Within this study we will investigate the precision and reproducibility of automated, computer-guided PASI measurements in comparison to trained physicians to address these limitations. Non-interventional analyses of PASI calculations by either physicians in a prospective versus retrospective setting or an automated computer-guided algorithm in 120 patients with plaque psoriasis. All retrospective PASI calculations by physicians or by the computer algorithm are based on total body digital images. The primary objective of this study is comparison of automated computer-guided PASI measurements by means of digital image analysis versus conventional, prospective or retrospective physicians' PASI assessments. Secondary endpoints include (1) the assessment of physicians' interobserver variance in PASI calculations, (2) the assessment of physicians' intraobserver variance in PASI assessments of the same patients' images after a time interval of at least 4 weeks, (3) the assessment of the deviation between physicians' prospective versus retrospective PASI calculations, and (4) the reproducibility of automated computer-guided PASI measurements by assessment of two sets of total body digital images of the same patients taken at one time point. Ethical approval was provided by the Ethics Committee of the Medical Faculty of the University of Heidelberg (ethics approval number S-379/2016). DRKS00011818; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
An adaptive management approach to controlling suburban deer
Nielson, C.K.; Porter, W.F.; Underwood, H.B.
1997-01-01
Distance sight-resight sampling has particular relevance to aerial surveys, in which height above ground and aircraft speed make the critical assumption of certain detection on the track-line unrealistic. Recent developments in distance sight-resight theory have left practical issues related to data collection as the major impediment to widespread use of distance sight-resight sampling in aerial surveys. We describe and evaluate a system to automatically log, store, and process data from distance sight-resight aerial surveys. The system has a primary digital system and a secondary audio system. The digital system comprises a sighting 'gun' and small keypad for each observer, a global positioning system (GPS) receiver, and an altimeter interface, all linked to a central laptop computer. The gun is used to record time and angle of declination from the horizon of sighted groups of animals as they pass the aircraft. The keypad is used to record information on species and group size. The altimeter interface records altitude from the aircraft's radar altimeter, and the GPS receiver provides location data at user-definable intervals. We wrote software to import data into a database and convert it into a form appropriate for distance sight-resight analyses. Perpendicular distance of sighted groups of animals from the flight path is calculated from altitude and angle of declination. Time, angle of declination, species, and group size of sightings by independent observers on the same side of the aircraft are used as criteria to classify single and duplicate sightings, allowing testing of the critical distance sampling assumption (g(0)=1) and estimation of g(0) if that assumption fails. An audio system comprising headphones for each observer and a 4-track tape recorder allows recording of data that are difficult to accommodate in the digital system and provides a backup to the digital system. We evaluated the system by conducting experimental surveys and reviewing results from actual surveys.
Evaluation of commercial ADC radiation tolerance for accelerator experiments
Chen, K.; Chen, H.; Kierstead, J.; ...
2015-08-17
Electronic components used in high energy physics experiments are subjected to a radiation background composed of high energy hadrons, mesons and photons. These particles can induce permanent and transient effects that affect the normal device operation. Ionizing dose and displacement damage can cause chronic damage which disable the device permanently. Transient effects or single event effects are in general recoverable with time intervals that depend on the nature of the failure. The magnitude of these effects is technology dependent with feature size being one of the key parameters. Analog to digital converters are components that are frequently used in detectormore » front end electronics, generally placed as close as possible to the sensing elements to maximize signal fidelity. We report on radiation effects tests conducted on 17 commercially available analog to digital converters and extensive single event effect measurements on specific twelve and fourteen bit ADCs that presented high tolerance to ionizing dose. We discuss mitigation strategies for single event effects (SEE) for their use in the large hadron collider environment.« less
Ambulatory ventricular function monitor: validation and preliminary clinical results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, R.A.; Sullivan, P.J.; Moore, R.H.
1983-09-01
A device for the continuous measurement of left ventricular (LV) function was tested in a series of 34 subjects. The instrument consisted of 2 arrays of radiation sensitive cadmium telluride detectors held in place over the region of the left ventricle and lung by a vest-like garment (hence the name VEST). The VEST electronic instrumentation included analog-to-digital converters, a battery pack, microprocessor and gating device, which were worn in a back pack. Data generated by the VEST, including the digitized average electrocardiogram, RR interval, counts/13 ms in each radiation detector, and time since commencement of data recording, were recorded onmore » a cassette tape recorder every 2 minutes for subsequent analysis. At the conclusion of conventional multigated blood pool imaging, the VEST was positioned and worn by the subjects while supine, standing in place and walking. The correlation of ejection fraction calculated independently from the VEST and scintillation camera data was >0.95. The inter-record reproducibility of the ejection fraction measured by the VEST in sedentary subjects was <3%. 22 references, 6 figures.« less
A solid-state digital temperature recorder for space use
NASA Technical Reports Server (NTRS)
Westbrook, R. M.; Bennett, L. D.; Steinhaver, R. A.; Deboo, G. J.
1981-01-01
A solid-state, digital, temperature recorder has been developed for use in space experiments. The recorder is completely self-contained and includes a temperature sensor; all necessary electronics for signal conditioning, processing, storing, control and timing; and a battery power supply. No electrical interfacing with the particular spacecraft on which the unit is used is required. The recorder is small, light, and sturdy, and has no moving parts. It uses only biocompatible materials and has passed vibration and shock spaceflight qualification tests. The unit is capable of storing 2048, -10 to +45 C, 8-bit temperature measurements taken at intervals selectable by factors of 2 from 1.875 to 240 min; data can be retained for at least 6 months. The basic recorder can be simplified to accommodate a variety of applications by adding memory to allow more data to be recorded, by changing the front end to permit measurements other than temperature to be made, and by using different batteries to realize various operating periods. Stored flight data are read out from the recorder by means of a ground read-out unit.
Linear and volumetric dimensional changes of injection-molded PMMA denture base resins.
El Bahra, Shadi; Ludwig, Klaus; Samran, Abdulaziz; Freitag-Wolf, Sandra; Kern, Matthias
2013-11-01
The aim of this study was to evaluate the linear and volumetric dimensional changes of six denture base resins processed by their corresponding injection-molding systems at 3 time intervals of water storage. Two heat-curing (SR Ivocap Hi Impact and Lucitone 199) and four auto-curing (IvoBase Hybrid, IvoBase Hi Impact, PalaXpress, and Futura Gen) acrylic resins were used with their specific injection-molding technique to fabricate 6 specimens of each material. Linear and volumetric dimensional changes were determined by means of a digital caliper and an electronic hydrostatic balance, respectively, after water storage of 1, 30, or 90 days. Means and standard deviations of linear and volumetric dimensional changes were calculated in percentage (%). Statistical analysis was done using Student's and Welch's t tests with Bonferroni-Holm correction for multiple comparisons (α=0.05). Statistically significant differences in linear dimensional changes between resins were demonstrated at all three time intervals of water immersion (p≤0.05), with exception of the following comparisons which showed no significant difference: IvoBase Hi Impact/SR Ivocap Hi Impact and PalaXpress/Lucitone 199 after 1 day, Futura Gen/PalaXpress and PalaXpress/Lucitone 199 after 30 days, and IvoBase Hybrid/IvoBase Hi Impact after 90 days. Also, statistically significant differences in volumetric dimensional changes between resins were found at all three time intervals of water immersion (p≤0.05), with exception of the comparison between PalaXpress and Futura Gen. Denture base resins (IvoBase Hybrid and IvoBase Hi Impact) processed by the new injection-molding system (IvoBase), revealed superior dimensional precision. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
CropWatch agroclimatic indicators (CWAIs) for weather impact assessment on global agriculture.
Gommes, René; Wu, Bingfang; Zhang, Ning; Feng, Xueliang; Zeng, Hongwei; Li, Zhongyuan; Chen, Bo
2017-02-01
CropWatch agroclimatic indicators (CWAIs) are a monitoring tool developed by the CropWatch global crop monitoring system in the Chinese Academy of Sciences (CAS; www.cropwatch.com.cn , Wu et al Int J Digital Earth 7(2):113-137, 2014, Wu et al Remote Sens 7:3907-3933, 2015). Contrary to most other environmental and agroclimatic indicators, they are "agronomic value-added", i.e. they are spatial values averaged over agricultural areas only and they include a weighting that enhances the contribution of the areas with the largest production potential. CWAIs can be computed for any time interval (starting from dekads) and yield one synthetic value per variable over a specific area and time interval, for instance a national annual value. Therefore, they are very compatible with socio-economic and other variables that are usually reported at regular time intervals over administrative units, such as national environmental or agricultural statistics. Two of the CWAIs are satellite-based (RAIN and Photosynthetically Active radiation, PAR) while the third is ground based (TEMP, air temperature); capitals are used when specifically referring to CWAIs rather than the climate variables in general. The paper first provides an overview of some common agroclimatic indicators, describing their procedural, systemic and normative features in subsequent sections, following the terminology of Binder et al Environ Impact Assess Rev 30:71-81 (2010). The discussion focuses on the systemic and normative aspects: the CWAIs are assessed in terms of their coherent description of the agroclimatic crop environment, at different spatial scales (systemic). The final section shows that the CWAIs retain key statistical properties of the underlying climate variables and that they can be compared to a reference value and used as monitoring and early warning variables (normative).
CropWatch agroclimatic indicators (CWAIs) for weather impact assessment on global agriculture
NASA Astrophysics Data System (ADS)
Gommes, René; Wu, Bingfang; Zhang, Ning; Feng, Xueliang; Zeng, Hongwei; Li, Zhongyuan; Chen, Bo
2017-02-01
CropWatch agroclimatic indicators (CWAIs) are a monitoring tool developed by the CropWatch global crop monitoring system in the Chinese Academy of Sciences (CAS; http://www.cropwatch.com.cn, Wu et al Int J Digital Earth 7(2):113-137, 2014, Wu et al Remote Sens 7:3907-3933, 2015). Contrary to most other environmental and agroclimatic indicators, they are "agronomic value-added", i.e. they are spatial values averaged over agricultural areas only and they include a weighting that enhances the contribution of the areas with the largest production potential. CWAIs can be computed for any time interval (starting from dekads) and yield one synthetic value per variable over a specific area and time interval, for instance a national annual value. Therefore, they are very compatible with socio-economic and other variables that are usually reported at regular time intervals over administrative units, such as national environmental or agricultural statistics. Two of the CWAIs are satellite-based (RAIN and Photosynthetically Active radiation, PAR) while the third is ground based (TEMP, air temperature); capitals are used when specifically referring to CWAIs rather than the climate variables in general. The paper first provides an overview of some common agroclimatic indicators, describing their procedural, systemic and normative features in subsequent sections, following the terminology of Binder et al Environ Impact Assess Rev 30:71-81 (2010). The discussion focuses on the systemic and normative aspects: the CWAIs are assessed in terms of their coherent description of the agroclimatic crop environment, at different spatial scales (systemic). The final section shows that the CWAIs retain key statistical properties of the underlying climate variables and that they can be compared to a reference value and used as monitoring and early warning variables (normative).
Calculation of power spectrums from digital time series with missing data points
NASA Technical Reports Server (NTRS)
Murray, C. W., Jr.
1980-01-01
Two algorithms are developed for calculating power spectrums from the autocorrelation function when there are missing data points in the time series. Both methods use an average sampling interval to compute lagged products. One method, the correlation function power spectrum, takes the discrete Fourier transform of the lagged products directly to obtain the spectrum, while the other, the modified Blackman-Tukey power spectrum, takes the Fourier transform of the mean lagged products. Both techniques require fewer calculations than other procedures since only 50% to 80% of the maximum lags need be calculated. The algorithms are compared with the Fourier transform power spectrum and two least squares procedures (all for an arbitrary data spacing). Examples are given showing recovery of frequency components from simulated periodic data where portions of the time series are missing and random noise has been added to both the time points and to values of the function. In addition the methods are compared using real data. All procedures performed equally well in detecting periodicities in the data.
Timing performance comparison of digital methods in positron emission tomography
NASA Astrophysics Data System (ADS)
Aykac, Mehmet; Hong, Inki; Cho, Sanghee
2010-11-01
Accurate timing information is essential in positron emission tomography (PET). Recent improvements in high speed electronics made digital methods more attractive to find alternative solutions to create a time mark for an event. Two new digital methods (mean PMT pulse model, MPPM, and median filtered zero crossing method, MFZCM) were introduced in this work and compared to traditional methods such as digital leading edge (LE) and digital constant fraction discrimination (CFD). In addition, the performances of all four digital methods were compared to analog based LE and CFD. The time resolution values for MPPM and MFZCM were measured below 300 ps at 1.6 GS/s and above that was similar to the analog based coincidence timing results. In addition, the two digital methods were insensitive to the changes in threshold setting that might give some improvement in system dead time.
NASA Astrophysics Data System (ADS)
Baturin, A. P.; Votchel, I. A.
2013-12-01
The problem of asteroid motion sumulation has been considered. At present this simulation is being performed by means of numerical integration taking into account the pertubations from planets and the Moon with some their ephemerides (DE405, DE422, etc.). All these ephemerides contain coefficients for Chebyshev polinomials for the great amount of equal interpolation intervals. However, all ephemerides has been constructed to keep at the junctions of adjacent intervals a continuity of just coordinates and their first derivatives (just in 16-digit decimal format corre-sponding to 64-bit floating-point numbers). But as for the second and higher order derivatives, they have breaks at these junctions. These breaks, if they are within an integration step, decrease the accuracy of numerical integration. If to consider 34-digit format (128-bit floating point numbers) the coordinates and their first derivatives will also have breaks (at 15-16 decimal digit) at interpolation intervals' junctions. Two ways of elimination of influence of such breaks have been considered. The first one is a "smoothing" of ephemerides so that planets' coordinates and their de-rivatives up to some order will be continuous at the junctions. The smoothing algorithm is based on conditional least-square fitting of coefficients for Chebyshev polynomials, the conditions are equalities of coordinates and derivatives up to some order "from the left" and "from the right" at the each junction. The algorithm has been applied for the smoothing of ephemerides DE430 just up to the first-order derivatives. The second way is a correction of integration step so that junctions does not lie within the step and always coincide with its end. But this way may be applied just at 16-digit decimal precision because it assumes a continuity of planets' coordinates and their first derivatives. Both ways was applied in forward and backward numerical integration for asteroids Apophis and 2012 DA14 by means of 15- and 31-order Everhart method at 16- and 34-digit decimal precision correspondently. The ephemerides DE430 (in its original and smoothed form) has been used for the calculation of perturbations. The results of the research indicate that the integration step correction increases a numercal integration accuracy by 3-4 orders. If, in addition, to replace the original ephemerides by the smoothed ones the accuracy increases approximately by 10 orders.
Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M
2013-10-01
Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.
Zhao, Longshan; Wu, Faqi
2015-01-01
In this study, a simple travel time-based runoff model was proposed to simulate a runoff hydrograph on soil surfaces with different microtopographies. Three main parameters, i.e., rainfall intensity (I), mean flow velocity (v m) and ponding time of depression (t p), were inputted into this model. The soil surface was divided into numerous grid cells, and the flow length of each grid cell (l i) was then calculated from a digital elevation model (DEM). The flow velocity in each grid cell (v i) was derived from the upstream flow accumulation area using v m. The total flow travel time through each grid cell to the surface outlet was the sum of the sum of flow travel times along the flow path (i.e., the sum of l i/v i) and t p. The runoff rate at the slope outlet for each respective travel time was estimated by finding the sum of the rain rate from all contributing cells for all time intervals. The results show positive agreement between the measured and predicted runoff hydrographs. PMID:26103635
Zhao, Longshan; Wu, Faqi
2015-01-01
In this study, a simple travel time-based runoff model was proposed to simulate a runoff hydrograph on soil surfaces with different microtopographies. Three main parameters, i.e., rainfall intensity (I), mean flow velocity (vm) and ponding time of depression (tp), were inputted into this model. The soil surface was divided into numerous grid cells, and the flow length of each grid cell (li) was then calculated from a digital elevation model (DEM). The flow velocity in each grid cell (vi) was derived from the upstream flow accumulation area using vm. The total flow travel time through each grid cell to the surface outlet was the sum of the sum of flow travel times along the flow path (i.e., the sum of li/vi) and tp. The runoff rate at the slope outlet for each respective travel time was estimated by finding the sum of the rain rate from all contributing cells for all time intervals. The results show positive agreement between the measured and predicted runoff hydrographs.
DeSmet, Ann; Shegog, Ross; Van Ryckeghem, Dimitri; Crombez, Geert; De Bourdeaudhuij, Ilse
2015-04-01
Serious games may be effective in promoting sexual health behavior. Their confidential nature may encourage users to discuss sensitive sexuality topics. Furthermore, they can tailor messages to the individual's needs and may be intrinsically motivating. This meta-analysis investigates the effectiveness of interventions for sexual health promotion that use serious games. A database search was conducted in PubMed, Web of Science, CINAHL, and PsycINFO for publications before the end of July 2013. Serious digital games studies measuring effects on behavior or its determinants, using a control condition, allowing the calculation of an effect size (Hedges' g, random-effects model) were included. Seven game studies for sexual health promotion were included. These showed positive effects on determinants (g=0.242; 95 percent confidence interval, 0.129, 0.356), albeit of small effect size. The effects on behavior, measured in only two studies, were not significant (g=0.456; 95 percent confidence interval, -0.649, 1.561). Most games did not use many game features that are considered to be immersive or enhancing flow. Instead, there was a strong reliance on pure gamification features, such as rewards and feedback. The effectiveness of the next generation of games may be enhanced by building on the behavioral change and educational gaming literatures (e.g., using role-play and simulation game formats, individual tailoring, offering adaptation in the difficulty of the challenge, and amount and timing of the feedback). There is a need for studies with rigorous evaluations of game effectiveness, longer-term follow-up, and using measures of behavior rather than merely their determinants.
Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P
2018-01-01
Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4 seconds/case. This time can be minimized with experience and may be further balanced by the improved ease of electronic chart access allowed by digital slide viewing, as well as quantitative assessments which can be expedited on digital images.
NASA Technical Reports Server (NTRS)
Marcin, Martin; Abramovici, Alexander
2008-01-01
The software of a commercially available digital radio receiver has been modified to make the receiver function as a two-channel low-noise phase meter. This phase meter is a prototype in the continuing development of a phase meter for a system in which radiofrequency (RF) signals in the two channels would be outputs of a spaceborne heterodyne laser interferometer for detecting gravitational waves. The frequencies of the signals could include a common Doppler-shift component of as much as 15 MHz. The phase meter is required to measure the relative phases of the signals in the two channels at a sampling rate of 10 Hz at a root power spectral density <5 microcycle/(Hz)1/2 and to be capable of determining the power spectral density of the phase difference over the frequency range from 1 mHz to 1 Hz. Such a phase meter could also be used on Earth to perform similar measurements in laser metrology of moving bodies. To illustrate part of the principle of operation of the phase meter, the figure includes a simplified block diagram of a basic singlechannel digital receiver. The input RF signal is first fed to the input terminal of an analog-to-digital converter (ADC). To prevent aliasing errors in the ADC, the sampling rate must be at least twice the input signal frequency. The sampling rate of the ADC is governed by a sampling clock, which also drives a digital local oscillator (DLO), which is a direct digital frequency synthesizer. The DLO produces samples of sine and cosine signals at a programmed tuning frequency. The sine and cosine samples are mixed with (that is, multiplied by) the samples from the ADC, then low-pass filtered to obtain in-phase (I) and quadrature (Q) signal components. A digital signal processor (DSP) computes the ratio between the Q and I components, computes the phase of the RF signal (relative to that of the DLO signal) as the arctangent of this ratio, and then averages successive such phase values over a time interval specified by the user.
Pneumothorax size measurements on digital chest radiographs: Intra- and inter- rater reliability.
Thelle, Andreas; Gjerdevik, Miriam; Grydeland, Thomas; Skorge, Trude D; Wentzel-Larsen, Tore; Bakke, Per S
2015-10-01
Detailed and reliable methods may be important for discussions on the importance of pneumothorax size in clinical decision-making. Rhea's method is widely used to estimate pneumothorax size in percent based on chest X-rays (CXRs) from three measure points. Choi's addendum is used for anterioposterior projections. The aim of this study was to examine the intrarater and interrater reliability of the Rhea and Choi method using digital CXR in the ward based PACS monitors. Three physicians examined a retrospective series of 80 digital CXRs showing pneumothorax, using Rhea and Choi's method, then repeated in a random order two weeks later. We used the analysis of variance technique by Eliasziw et al. to assess the intrarater and interrater reliability in altogether 480 estimations of pneumothorax size. Estimated pneumothorax sizes ranged between 5% and 100%. The intrarater reliability coefficient was 0.98 (95% one-sided lower-limit confidence interval C 0.96), and the interrater reliability coefficient was 0.95 (95% one-sided lower-limit confidence interval 0.93). This study has shown that the Rhea and Choi method for calculating pneumothorax size has high intrarater and interrater reliability. These results are valid across gender, side of pneumothorax and whether the patient is diagnosed with primary or secondary pneumothorax. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Effects of repeated gas sterilization on closure rates of ameroid ring constrictors in vitro.
Kimberlin, William W; Wardlaw, Jennifer L; Madsen, Richard W
2016-01-01
To determine the effect of repeated gas sterilization on rate of closure of ameroid ring constrictors in vitro. Twenty-four 3.5-mm ameroid ring constrictors. Ameroid ring constrictors were allocated to 1 of 4 treatment groups (6/group) to undergo gas sterilization 0, 1, 5, or 10 times. After sterilization, constrictors were incubated in canine plasma at a protein concentration of 3 g/dL for 27 days. A digital camera was used to obtain images of the constrictors prior to and at various points during incubation, and lumen diameter was measured. Mean ± SD percentage of lumen closure for all groups of ameroid ring constrictors combined was 85.2 ± 1.6% at day 0 (prior to plasma incubation) and 95.4 ± 0.8% at day 27. Mean lumen area was 3.64 ± 0.43 mm(2) (95% confidence interval, 2.67 to 4.77 mm(2)) at day 0 and 1.32 ± 0.25 mm(2) (95% confidence interval, 0.76 to 2.04 mm(2)) at day 27. None of the ameroid ring constrictors had closed completely by day 27. Overall closure rates for ameroid ring constrictors appeared to be unaffected by repeated gas sterilization up to 10 times. Findings suggested that veterinary surgeons can resterilize ameroid ring constrictors up to 10 times with confidence that ring properties would remain suitable for clinical use.
Optical Diagnostic System For Observation Of Laser-Produced Shock Waves
NASA Astrophysics Data System (ADS)
Wilke, Mark D.; Stone, Sidney N.
1980-11-01
Several standard plasma and gas dynamic diagnostic techniques have been integrated into a system for observing the formation and propagation of high-power Nd:glass-laser generated one- and two-dimensional shockwaves in air from 0.1 torr to atmospheric pres-sures. Diagnostics include either single-frame, two-wavelength holographic ruby-laser interferometry or single-frame, single-wavelength interferometry with ten frames of shadow-graphy. Streaks or ten frames of the early luminous shocked region also are taken on all shots, as well as time-resolved luminosity measurements using high-speed biplanar vacuum photodiodes with various wavelength interference filters. Shadowgraphy frames are 200-ns long at 1-μs intervals, while emission frames are variable with a maximum 10-ns exposure and 50-ns interval. Both the streak mode and emission measurements with the vacuum diode allow subnanosecond time resolution. The interferometry provides 20-ns exposures from 500 ns to late times. Methods for reducing and interpreting the data have been, or are currently being, developed. Interactive computer programs for digitizing the fringe patterns provide fringe-shift profiles for Abel inversion. This has provided neutral gas and electron density information in the spherical, one-dimensional cases. Diagrams and photographs of the experiment will be shown as well as examples of the data that have been taken. Methods for data reduction will be outlined and some of the results shown.
Wang, JianLi; Smailes, Elizabeth; Sareen, Jitender; Fick, Gordon H; Schmitz, Norbert; Patten, Scott B
2010-09-01
The ongoing global economic crisis may have affected people's mental health. This study aimed to, among a sample of the working population, estimate and compare the prevalence of depressive and anxiety disorders in different time intervals from January 2008 to October 2009 and to examine the demographic and socioeconomic correlates of mental disorders. From January 2008 to October 2009, 3579 employees in Alberta were recruited using the random digit dialing method. Mental disorders were assessed using the World Health Organization's Composite International Diagnostic Interview-Auto 2.1. The lifetime and 12-month prevalence of depressive and anxiety disorders in different time intervals were estimated and compared. The 12-month prevalence of major depressive disorder (MDD) before September 1, 2008; between September 1, 2008, and March 1, 2009; and between March 1, 2009, and October 30, 2009, was 5.1%, 6.8%, and 7.6% (P = 0.03), respectively. The lifetime prevalence of dysthymia reported during the 3 periods was 0.4%, 0.7%, and 1.5% (P = 0.006), respectively. No changes in the 12-month prevalence of social phobia, panic disorder, and generalized anxiety disorder were found over time. The ongoing global economic crisis may have contributed to the increased prevalence of MDD. Future studies are needed to monitor the changes in the prevalence and to describe how the event may affect people's employment status, income, and health.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Araya, Million
2015-08-21
SPEAR3 is a 234 m circular storage ring at SLAC’s synchrotron radiation facility (SSRL) in which a 3 GeV electron beam is stored for user access. Typically the electron beam decays with a time constant of approximately 10hr due to electron lose. In order to replenish the lost electrons, a booster synchrotron is used to accelerate fresh electrons up to 3GeV for injection into SPEAR3. In order to maintain a constant electron beam current of 500mA, the injection process occurs at 5 minute intervals. At these times the booster synchrotron accelerates electrons for injection at a 10Hz rate. A 10Hzmore » 'injection ready' clock pulse train is generated when the booster synchrotron is operating. Between injection intervals-where the booster is not running and hence the 10 Hz ‘injection ready’ signal is not present-a 10Hz clock is derived from the power line supplied by Pacific Gas and Electric (PG&E) to keep track of the injection timing. For this project I constructed a multiplexing circuit to 'switch' between the booster synchrotron 'injection ready' clock signal and PG&E based clock signal. The circuit uses digital IC components and is capable of making glitch-free transitions between the two clocks. This report details construction of a prototype multiplexing circuit including test results and suggests improvement opportunities for the final design.« less
Musser, Jonathan W.
2018-01-31
Digital flood-inundation maps for a 12.6-mile reach of the Withlacoochee River from Skipper Bridge Road to St. Augustine Road (Georgia State Route 133) were developed to depict estimates of the areal extent and depth of flooding corresponding to selected water levels (stages) at the U.S. Geological Survey (USGS) streamgage at Withlacoochee River at Skipper Bridge Road, near Bemiss, Ga. (023177483). Real-time stage information from this streamgage can be used with these maps to estimate near real-time areas of inundation. The forecasted peak-stage information for the USGS streamgage at Withlacoochee River at Skipper Bridge Road, near Bemiss, Ga. (023177483), can be used in conjunction with the maps developed for this study to show predicted areas of flood inundation.A one-dimensional step-backwater model was developed using the U.S. Army Corps of Engineers Hydrologic Engineer-ing Center’s River Analysis System (HEC–RAS) software for the Withlacoochee River and was used to compute flood profiles for a 12.6-mile reach of the Withlacoochee River. The hydraulic model was then used to simulate 23 water-surface profiles at 1.0-foot (ft) intervals at the Withlacoochee River near the Bemiss streamgage. The profiles ranged from the National Weather Service action stage of 10.7 ft, which is 131.0 ft above the North American Vertical Datum of 1988 (NAVD 88), to a stage of 32.7 ft, which is 153.0 ft above NAVD 88. The simulated water-surface profiles were then combined with a geographic information system digital elevation model—derived from light detection and ranging (lidar) data having a 4.0-ft horizontal resolution—to delineate the area flooded at each 1.0-ft interval of stream stage.
Osborne, Peter G; Chou, Tung-Shan; Shen, Tsu-Wang
2011-01-01
Betel quid use and abuse is wide spread in Asia but the physiological basis of intoxication and addiction are unknown. In subjects naïve to the habit of betel quid intoxication, the psychological and physiological profile of intoxication has never been reported. We compared the effect of chewing gum or chewing betel quid, and subsequent betel quid intoxication, on psychological assessment, prospective time interval estimation, numerical and character digit span, computerized 2 choice tests and mental tasks such as reading and mathematics with concurrent monitoring of ECG, EEG and face temperature in healthy, non-sleep deprived, male subjects naïve to the habit of chewing betel quid. Betel quid intoxication, dose dependently induced tachycardia (max 30 bpm) and elevated face temperature (0.7°C) (P<0.001) above the effects observed in response to chewing gum (max 12 bpm and 0.3°C) in 12 subjects. Gross behavioral indices of working memory such as numerical or character digit span in 8 subjects, or simple visual-motor performance such as reaction speed or accuracy in a two choice scenario in 8 subjects were not affected by betel quid intoxication. Betel quid intoxication strongly influenced the psychological aspects of perception such as slowing of the prospective perception of passage of a 1 minute time interval in 8 subjects (P<0.05) and perceived increased arousal (P<0.01) and perceived decreased ability to think (P<0.05) in 31 subjects. The EEG spectral profile recorded from mental states associated with open and closed eyes, and mental tasks such as reading and eyes closed mental arithmetic were significantly modified (P<0.05) relative to chewing gum by betel quid intoxication in 10 subjects. The prevalence of betel quid consumption across a range of social and work settings warrants greater investigation of this widespread but largely under researched drug.
Osborne, Peter G.; Chou, Tung-Shan; Shen, Tsu-Wang
2011-01-01
Betel quid use and abuse is wide spread in Asia but the physiological basis of intoxication and addiction are unknown. In subjects naïve to the habit of betel quid intoxication, the psychological and physiological profile of intoxication has never been reported. We compared the effect of chewing gum or chewing betel quid, and subsequent betel quid intoxication, on psychological assessment, prospective time interval estimation, numerical and character digit span, computerized 2 choice tests and mental tasks such as reading and mathematics with concurrent monitoring of ECG, EEG and face temperature in healthy, non-sleep deprived, male subjects naïve to the habit of chewing betel quid. Betel quid intoxication, dose dependently induced tachycardia (max 30 bpm) and elevated face temperature (0.7°C) (P<0.001) above the effects observed in response to chewing gum (max 12 bpm and 0.3°C) in 12 subjects. Gross behavioral indices of working memory such as numerical or character digit span in 8 subjects, or simple visual-motor performance such as reaction speed or accuracy in a two choice scenario in 8 subjects were not affected by betel quid intoxication. Betel quid intoxication strongly influenced the psychological aspects of perception such as slowing of the prospective perception of passage of a 1 minute time interval in 8 subjects (P<0.05) and perceived increased arousal (P<0.01) and perceived decreased ability to think (P<0.05) in 31 subjects. The EEG spectral profile recorded from mental states associated with open and closed eyes, and mental tasks such as reading and eyes closed mental arithmetic were significantly modified (P<0.05) relative to chewing gum by betel quid intoxication in 10 subjects. The prevalence of betel quid consumption across a range of social and work settings warrants greater investigation of this widespread but largely under researched drug. PMID:21909371
NASA Astrophysics Data System (ADS)
Sepulveda, F.; Thangraj, J. S.; Quiros, D.; Pulliam, J.; Queen, J. H.; Queen, M.; Iovenitti, J. L.
2017-12-01
Seismic interferometry that makes use of ambient noise requires that cross-correlations of data recorded at two or more stations be stacked over a "long enough" time interval that off-axis sources cancel and the estimated inter-station Green's function converges to the actual function. However, the optimal length of the recording period depends on the characteristics of ambient noise at the site, which vary over time and are therefore not known before data acquisition. Data acquisition parameters cannot be planned in ways that will ensure success while minimizing cost and effort. Experiment durations are typically either too long or too short. Automated, in-field processing can provide inter-station Green's functions in near-real-time, allowing for the immediate evaluation of results and enabling operators to alter data acquisition parameters before demobilizing. We report on the design, system integration, and testing of a strategy for the automation of data acquisition, distribution, and processing of ambient noise using industry-standard, widely-available instrumentation (Reftek 130-01 digitizers and 4.5 Hz geophones). Our solution utilizes an inexpensive embedded system (Raspberry Pi 3), which is configured to acquire data from the Reftek and insert it into a big data store called Apache Cassandra. Cassandra distributes and maintains up-to-date copies of the data, through a WiFi network, as defined by tunable consistency levels and replication factors thus allowing for efficient multi-station computations. At regular intervals, data is extracted from Cassandra and is used to compute Green's functions for all receiver pairs. Results are reviewed and progress toward convergence can be assessed. We successfully tested a 20-node prototype of what we call the "Raspberry Pi-Enhanced Reftek" (RaPiER) array at the Soda Lake Geothermal Field in Nevada in June 2017. While intermittent problems with the WiFi network interfered with the real-time data delivery from some stations, the system performed robustly overall and produced hourly sets of steadily improving virtual source gathers. Most importantly, the effects of data shortfalls on results can be assessed immediately, in the field, so the array's acquisition parameters can be modified and the deployment duration extended as necessary.
ERIC Educational Resources Information Center
Cirell, Anna Montana
2017-01-01
Digital media is becoming increasingly important to learning in today's changing times. At the same time, digital technologies and related digital skills are unevenly distributed. Further, deficit-based notions of this digital divide define the public's educational paradigm. Against this backdrop, I forayed into the social reality of one rural…
Fidler, Samantha; D'Orsogna, Lloyd; Irish, Ashley B; Lewis, Joshua R; Wong, Germaine; Lim, Wai H
2018-03-02
Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960-0.975) and 0.926 (95% CI 0.899-0.944), respectively; and 0.995 (95% CI 0.994-0.996) and 0.993 (95% CI 0.991-0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation.
Computer Program Recognizes Patterns in Time-Series Data
NASA Technical Reports Server (NTRS)
Hand, Charles
2003-01-01
A computer program recognizes selected patterns in time-series data like digitized samples of seismic or electrophysiological signals. The program implements an artificial neural network (ANN) and a set of N clocks for the purpose of determining whether N or more instances of a certain waveform, W, occur within a given time interval, T. The ANN must be trained to recognize W in the incoming stream of data. The first time the ANN recognizes W, it sets clock 1 to count down from T to zero; the second time it recognizes W, it sets clock 2 to count down from T to zero, and so forth through the Nth instance. On the N + 1st instance, the cycle is repeated, starting with clock 1. If any clock has not reached zero when it is reset, then N instances of W have been detected within time T, and the program so indicates. The program can readily be encoded in a field-programmable gate array or an application-specific integrated circuit that could be used, for example, to detect electroencephalographic or electrocardiographic waveforms indicative of epileptic seizures or heart attacks, respectively.
Toward a quantitative account of pitch distribution in spontaneous narrative: Method and validation
Matteson, Samuel E.; Streit Olness, Gloria; Caplow, Nancy J.
2013-01-01
Pitch is well-known both to animate human discourse and to convey meaning in communication. The study of the statistical population distributions of pitch in discourse will undoubtedly benefit from methodological improvements. The current investigation examines a method that parameterizes pitch in discourse as musical pitch interval H measured in units of cents and that disaggregates the sequence of peak word-pitches using tools employed in time-series analysis and digital signal processing. The investigators test the proposed methodology by its application to distributions in pitch interval of the peak word-pitch (collectively called the discourse gamut) that occur in simulated and actual spontaneous emotive narratives obtained from 17 middle-aged African-American adults. The analysis, in rigorous tests, not only faithfully reproduced simulated distributions imbedded in realistic time series that drift and include pitch breaks, but the protocol also reveals that the empirical distributions exhibit a common hidden structure when normalized to a slowly varying mode (called the gamut root) of their respective probability density functions. Quantitative differences between narratives reveal the speakers' relative propensity for the use of pitch levels corresponding to elevated degrees of a discourse gamut (the “e-la”) superimposed upon a continuum that conforms systematically to an asymmetric Laplace distribution. PMID:23654400
Artifacts in Digital Coincidence Timing
Moses, W. W.; Peng, Q.
2014-01-01
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into a time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator. All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e., the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the “optimal” method. The purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization. PMID:25321885
Artifacts in digital coincidence timing
Moses, W. W.; Peng, Q.
2014-10-16
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into amore » time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.« less
Artifacts in digital coincidence timing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moses, W. W.; Peng, Q.
Digital methods are becoming increasingly popular for measuring time differences, and are the de facto standard in PET cameras. These methods usually include a master system clock and a (digital) arrival time estimate for each detector that is obtained by comparing the detector output signal to some reference portion of this clock (such as the rising edge). Time differences between detector signals are then obtained by subtracting the digitized estimates from a detector pair. A number of different methods can be used to generate the digitized arrival time of the detector output, such as sending a discriminator output into amore » time to digital converter (TDC) or digitizing the waveform and applying a more sophisticated algorithm to extract a timing estimator.All measurement methods are subject to error, and one generally wants to minimize these errors and so optimize the timing resolution. A common method for optimizing timing methods is to measure the coincidence timing resolution between two timing signals whose time difference should be constant (such as detecting gammas from positron annihilation) and selecting the method that minimizes the width of the distribution (i.e. the timing resolution). Unfortunately, a common form of error (a nonlinear transfer function) leads to artifacts that artificially narrow this resolution, which can lead to erroneous selection of the 'optimal' method. In conclusion, the purpose of this note is to demonstrate the origin of this artifact and suggest that caution should be used when optimizing time digitization systems solely on timing resolution minimization.« less
Silva, Paolo S; Walia, Saloni; Cavallerano, Jerry D; Sun, Jennifer K; Dunn, Cheri; Bursell, Sven-Erik; Aiello, Lloyd M; Aiello, Lloyd Paul
2012-09-01
To compare agreement between diagnosis of clinical level of diabetic retinopathy (DR) and diabetic macular edema (DME) derived from nonmydriatic fundus images using a digital camera back optimized for low-flash image capture (MegaVision) compared with standard seven-field Early Treatment Diabetic Retinopathy Study (ETDRS) photographs and dilated clinical examination. Subject comfort and image acquisition time were also evaluated. In total, 126 eyes from 67 subjects with diabetes underwent Joslin Vision Network nonmydriatic retinal imaging. ETDRS photographs were obtained after pupillary dilation, and fundus examination was performed by a retina specialist. There was near-perfect agreement between MegaVision and ETDRS photographs (κ=0.81, 95% confidence interval [CI] 0.73-0.89) for clinical DR severity levels. Substantial agreement was observed with clinical examination (κ=0.71, 95% CI 0.62-0.80). For DME severity level there was near-perfect agreement with ETDRS photographs (κ=0.92, 95% CI 0.87-0.98) and moderate agreement with clinical examination (κ=0.58, 95% CI 0.46-0.71). The wider MegaVision 45° field led to identification of nonproliferative changes in areas not imaged by the 30° field of ETDRS photos. Field area unique to ETDRS photographs identified proliferative changes not visualized with MegaVision. Mean MegaVision acquisition time was 9:52 min. After imaging, 60% of subjects preferred the MegaVision lower flash settings. When evaluated using a rigorous protocol, images captured using a low-light digital camera compared favorably with ETDRS photography and clinical examination for grading level of DR and DME. Furthermore, these data suggest the importance of more extensive peripheral images and suggest that utilization of wide-field retinal imaging may further improve accuracy of DR assessment.
Zhang, Yong; Fu, Chunxia; Xing, Bin; Li, Wenyong; Qian, Jianping; Li, Sha; Wang, Hui; Fan, Xiaodan; Yan, Yujing; Wang, Yan’an; Yang, Xinting
2015-01-01
In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012) of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT), an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT), an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit. PMID:25831065
Li, Ming; Chen, Meixiang; Zhang, Yong; Fu, Chunxia; Xing, Bin; Li, Wenyong; Qian, Jianping; Li, Sha; Wang, Hui; Fan, Xiaodan; Yan, Yujing; Wang, Yan'an; Yang, Xinting
2015-01-01
In apple cultivation, simulation models may be used to monitor fruit size during the growth and development process to predict production levels and to optimize fruit quality. Here, Fuji apples cultivated in spindle-type systems were used as the model crop. Apple size was measured during the growing period at an interval of about 20 days after full bloom, with three weather stations being used to collect orchard temperature and solar radiation data at different sites. Furthermore, a 2-year dataset (2011 and 2012) of apple fruit size measurements were integrated according to the weather station deployment sites, in addition to the top two most important environment factors, thermal and sunshine hours, into the model. The apple fruit diameter and length were simulated using physiological development time (PDT), an indicator that combines important environment factors, such as temperature and photoperiod, as the driving variable. Compared to the model of calendar-based development time (CDT), an indicator counting the days that elapse after full bloom, we confirmed that the PDT model improved the estimation accuracy to within 0.2 cm for fruit diameter and 0.1 cm for fruit length in independent years using a similar data collection method in 2013. The PDT model was implemented to realize a web-based management information system for a digital orchard, and the digital system had been applied in Shandong Province, China since 2013. This system may be used to compute the dynamic curve of apple fruit size based on data obtained from a nearby weather station. This system may provide an important decision support for farmers using the website and short message service to optimize crop production and, hence, economic benefit.
Diagnostic digital cytopathology: Are we ready yet?
House, Jarret C.; Henderson-Jackson, Evita B.; Johnson, Joseph O.; Lloyd, Mark C.; Dhillon, Jasreman; Ahmad, Nazeel; Hakam, Ardeshir; Khalbuss, Walid E.; Leon, Marino E.; Chhieng, David; Zhang, Xiaohui; Centeno, Barbara A.; Bui, Marilyn M.
2013-01-01
Background: The cytology literature relating to diagnostic accuracy using whole slide imaging is scarce. We studied the diagnostic concordance between glass and digital slides among diagnosticians with different profiles to assess the readiness of adopting digital cytology in routine practice. Materials and Methods: This cohort consisted of 22 de-identified previously screened and diagnosed cases, including non-gynecological and gynecological slides using standard preparations. Glass slides were digitalized using Aperio ScanScope XT (×20 and ×40). Cytopathologists with (3) and without (3) digital experience, cytotechnologists (4) and senior pathology residents (2) diagnosed the digital slides independently first and recorded the results. Glass slides were read and recorded separately 1-3 days later. Accuracy of diagnosis, time to diagnosis and diagnostician's profile were analyzed. Results: Among 22 case pairs and four study groups, correct diagnosis (93% vs. 86%) was established using glass versus digital slides. Both methods more (>95%) accurately diagnosed positive cases than negatives. Cytopathologists with no digital experience were the most accurate in digital diagnosis, even the senior members. Cytotechnologists had the fastest diagnosis time (3 min/digital vs. 1.7 min/glass), but not the best accuracy. Digital time was 1.5 min longer than glass-slide time/per case for cytopathologists and cytotechnologists. Senior pathology residents were slower and less accurate with both methods. Cytopathologists with digital experience ranked 2nd fastest in time, yet last in accuracy for digital slides. Conclusions: There was good overall diagnostic agreement between the digital whole-slide images and glass slides. Although glass slide diagnosis was more accurate and faster, the results of technologists and pathologists with no digital cytology experience suggest that solid diagnostic ability is a strong indicator for readiness of digital adoption. PMID:24392242
Smartphone Photography as a Tool to Measure Knee Range of Motion.
Mica, Megan Conti; Wagner, Eric R; Shin, Alexander Y
2018-01-01
The objective of this study was to validate measuring knee range of motion (ROM) from smartphone photography. Thirty-two participants (64 knees) obtained smartphone photographs of knee flexion and extension. Surgeons obtained the same photographs and goniometric measurement of ROM. ROM was measured using Adobe Photoshop. Goniometer versus digital measurements, participant versus surgeon photographs, and interobserver measurements were analyzed. The average difference in goniometer and digital photograph measurements was 5°. The interclass correlation was .642(L) and .656(R). The Bland-Altman plots demonstrated that 29/32 digital measurements were within the 95% confidence interval (CI). Participants' versus researchers' photographs averaged a 2° difference. The interclass correlation was .924(L) and .91(R). Bland-Altman plots demonstrated that 31/32 measurements were within the 95% CI. Interobserver reliability averaged aROMdifference of 5°. The concordance coefficients were .647(L) and .723(R). Bland-Altman plots demonstrated that 30 of 32 digital measurements were within the 95% CI. Measuring knee ROM using smartphone digital photography is valid and reliable. (Journal of Surgical Orthopaedic Advances 27(1):52-57, 2018).
Interactive Digital Signal Processor
NASA Technical Reports Server (NTRS)
Mish, W. H.
1985-01-01
Interactive Digital Signal Processor, IDSP, consists of set of time series analysis "operators" based on various algorithms commonly used for digital signal analysis. Processing of digital signal time series to extract information usually achieved by applications of number of fairly standard operations. IDSP excellent teaching tool for demonstrating application for time series operators to artificially generated signals.
An automatic optimum kernel-size selection technique for edge enhancement
Chavez, Pat S.; Bauer, Brian P.
1982-01-01
Edge enhancement is a technique that can be considered, to a first order, a correction for the modulation transfer function of an imaging system. Digital imaging systems sample a continuous function at discrete intervals so that high-frequency information cannot be recorded at the same precision as lower frequency data. Because of this, fine detail or edge information in digital images is lost. Spatial filtering techniques can be used to enhance the fine detail information that does exist in the digital image, but the filter size is dependent on the type of area being processed. A technique has been developed by the authors that uses the horizontal first difference to automatically select the optimum kernel-size that should be used to enhance the edges that are contained in the image.
Enabling Real-Time Volume Rendering of Functional Magnetic Resonance Imaging on an iOS Device.
Holub, Joseph; Winer, Eliot
2017-12-01
Powerful non-invasive imaging technologies like computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI) are used daily by medical professionals to diagnose and treat patients. While 2D slice viewers have long been the standard, many tools allowing 3D representations of digital medical data are now available. The newest imaging advancement, functional MRI (fMRI) technology, has changed medical imaging from viewing static to dynamic physiology (4D) over time, particularly to study brain activity. Add this to the rapid adoption of mobile devices for everyday work and the need to visualize fMRI data on tablets or smartphones arises. However, there are few mobile tools available to visualize 3D MRI data, let alone 4D fMRI data. Building volume rendering tools on mobile devices to visualize 3D and 4D medical data is challenging given the limited computational power of the devices. This paper describes research that explored the feasibility of performing real-time 3D and 4D volume raycasting on a tablet device. The prototype application was tested on a 9.7" iPad Pro using two different fMRI datasets of brain activity. The results show that mobile raycasting is able to achieve between 20 and 40 frames per second for traditional 3D datasets, depending on the sampling interval, and up to 9 frames per second for 4D data. While the prototype application did not always achieve true real-time interaction, these results clearly demonstrated that visualizing 3D and 4D digital medical data is feasible with a properly constructed software framework.
Development open source microcontroller based temperature data logger
NASA Astrophysics Data System (ADS)
Abdullah, M. H.; Che Ghani, S. A.; Zaulkafilai, Z.; Tajuddin, S. N.
2017-10-01
This article discusses the development stages in designing, prototyping, testing and deploying a portable open source microcontroller based temperature data logger for use in rough industrial environment. The 5V powered prototype of data logger is equipped with open source Arduino microcontroller for integrating multiple thermocouple sensors with their module, secure digital (SD) card storage, liquid crystal display (LCD), real time clock and electronic enclosure made of acrylic. The program for the function of the datalogger is programmed so that 8 readings from the thermocouples can be acquired within 3 s interval and displayed on the LCD simultaneously. The recorded temperature readings at four different points on both hydrodistillation show similar profile pattern and highest yield of extracted oil was achieved on hydrodistillation 2 at 0.004%. From the obtained results, this study achieved the objective of developing an inexpensive, portable and robust eight channels temperature measuring module with capabilities to monitor and store real time data.
Skylab extravehicular mobility unit thermal simulator
NASA Technical Reports Server (NTRS)
Hixon, C. W.; Phillips, M. A.
1974-01-01
The analytical methods, thermal model, and user's instructions for the Skylab Extravehicular Mobility Unit (SEMU) routine are presented. This digital computer program was developed for detailed thermal performance predictions of the SEMU on the NASA-JSC Univac 1108 computer system. It accounts for conductive, convective, and radiant heat transfer as well as fluid flow and special component characterization. The program provides thermal performance predictions for a 967 node thermal model in one thirty-sixth (1/36) of mission time when operated at a calculating interval of three minutes (mission time). The program has the operational flexibility to: (1) accept card or magnetic tape data input for the thermal model describing the SEMU structure, fluid systems, crewman and component performance, (2) accept card and/or magnetic tape input of internally generated heat and heat influx from the space environment, and (3) output tabular or plotted histories of temperature, flow rates, and other parameters describing system operating modes.
SPA- STATISTICAL PACKAGE FOR TIME AND FREQUENCY DOMAIN ANALYSIS
NASA Technical Reports Server (NTRS)
Brownlow, J. D.
1994-01-01
The need for statistical analysis often arises when data is in the form of a time series. This type of data is usually a collection of numerical observations made at specified time intervals. Two kinds of analysis may be performed on the data. First, the time series may be treated as a set of independent observations using a time domain analysis to derive the usual statistical properties including the mean, variance, and distribution form. Secondly, the order and time intervals of the observations may be used in a frequency domain analysis to examine the time series for periodicities. In almost all practical applications, the collected data is actually a mixture of the desired signal and a noise signal which is collected over a finite time period with a finite precision. Therefore, any statistical calculations and analyses are actually estimates. The Spectrum Analysis (SPA) program was developed to perform a wide range of statistical estimation functions. SPA can provide the data analyst with a rigorous tool for performing time and frequency domain studies. In a time domain statistical analysis the SPA program will compute the mean variance, standard deviation, mean square, and root mean square. It also lists the data maximum, data minimum, and the number of observations included in the sample. In addition, a histogram of the time domain data is generated, a normal curve is fit to the histogram, and a goodness-of-fit test is performed. These time domain calculations may be performed on both raw and filtered data. For a frequency domain statistical analysis the SPA program computes the power spectrum, cross spectrum, coherence, phase angle, amplitude ratio, and transfer function. The estimates of the frequency domain parameters may be smoothed with the use of Hann-Tukey, Hamming, Barlett, or moving average windows. Various digital filters are available to isolate data frequency components. Frequency components with periods longer than the data collection interval are removed by least-squares detrending. As many as ten channels of data may be analyzed at one time. Both tabular and plotted output may be generated by the SPA program. This program is written in FORTRAN IV and has been implemented on a CDC 6000 series computer with a central memory requirement of approximately 142K (octal) of 60 bit words. This core requirement can be reduced by segmentation of the program. The SPA program was developed in 1978.
Experimental test of plant canopy reflectance models on cotton
NASA Technical Reports Server (NTRS)
Lemaster, E. W.
1973-01-01
Spectroradiometric data on the bidirectional reflectance function was collected for a cotton canopy as a function of observer zenith angle, observer angle, and solar zenith angle. The area under study was about 40 miles from the Gulf of Mexico and the prevailing winds blew inland such that cloud formation increased during the day. The standard reflectance panel was constructed of plywood that had been spray painted with a flat white latex paint. Physical and optical plant parameters were measured. A time lapse mechanism was constructed to operate a 16 mm movie camera such that single frames could be exposed at intervals of one per second up to one per hour. Data were digitized from a strip chart recorder and reflectance panel measurements.
Experiments and Demonstrations in Physics: Bar-Ilan Physics Laboratory (2nd Edition)
NASA Astrophysics Data System (ADS)
Kraftmakher, Yaakov
2014-08-01
The following sections are included: * Data-acquisition systems from PASCO * ScienceWorkshop 750 Interface and DataStudio software * 850 Universal Interface and Capstone software * Mass on spring * Torsional pendulum * Hooke's law * Characteristics of DC source * Digital storage oscilloscope * Charging and discharging a capacitor * Charge and energy stored in a capacitor * Speed of sound in air * Lissajous patterns * I-V characteristics * Light bulb * Short time intervals * Temperature measurements * Oersted's great discovery * Magnetic field measurements * Magnetic force * Magnetic braking * Curie's point I * Electric power in AC circuits * Faraday's law of induction I * Self-inductance and mutual inductance * Electromagnetic screening * LCR circuit I * Coupled LCR circuits * Probability functions * Photometric laws * Kirchhoff's rule for thermal radiation * Malus' law * Infrared radiation * Irradiance and illuminance
Time effects of food intake on the pharmacokinetics and pharmacodynamics of quazepam
Yasui-Furukori, Norio; Takahata, Takenori; Kondo, Tsuyoshi; Mihara, Kazuo; Kaneko, Sunao; Tateishi, Tomonori
2003-01-01
Aims There is little information on interaction between food and the hypnotic agent quazepam. We therefore studied the effects of food and its time interval on the pharmacokinetics and pharmacodynamics of quazepam. Methods A randomized three-phase crossover study with 2-week intervals was conducted. Nine healthy male volunteers took a single oral 20 mg dose of quazepam under the following conditions: 1) after fasting overnight; 2) 30 min after eating standard meal; or 3) 3 h after eating the same meal. Plasma concentrations of quazepam and its metabolite, 2-oxoquazepam and psychomotor function using the Digit Symbol Substitute Test (DSST), Stanford Sleepiness Scale (SSS) and Visual Analogue Scale were measured up to 48 h. Results During the food treatments at 30 min and 3 h before dosing, the peak concentrations (Cmax) were 300% (95% CI 260, 340%; P < 0.001) and 250% (95% CI 210, 290%; P < 0.01) of the corresponding value during the fasting phase. For quazepam, the area under the plasma concentration–time curve from 0 to 8 h measured at 30 min and 3 h before dosing was significantly increased, with the food treatments by 2.4-fold (95% CI 2.0; 2.8-fold; P < 0.001) and 2.1-fold (95% CI 1.7; 2.4-fold; P < 0.01), respectively. In response to pharmacokinetic changes, some of the pharmacodynamics (DSST, P < 0.05; SSS, P < 0.05) differed significantly between fasted status and fed status. No difference was found in any pharmacokinetic or pharmacodynamic parameters between the two food treatment phases. Conclusions A food effect on quazepam absorption is evident and continues at least until 3 h after food intake. The dosing of quazepam after a long period of ordinary fasting might reduce its efficacy because a 3 h interval between the timing of the evening meal and bedtime administration of hypnotics is regarded as normal in daily life. PMID:12680887
NASA Astrophysics Data System (ADS)
Bechet, P.; Mitran, R.; Munteanu, M.
2013-08-01
Non-contact methods for the assessment of vital signs are of great interest for specialists due to the benefits obtained in both medical and special applications, such as those for surveillance, monitoring, and search and rescue. This paper investigates the possibility of implementing a digital processing algorithm based on the MUSIC (Multiple Signal Classification) parametric spectral estimation in order to reduce the observation time needed to accurately measure the heart rate. It demonstrates that, by proper dimensioning the signal subspace, the MUSIC algorithm can be optimized in order to accurately assess the heart rate during an 8-28 s time interval. The validation of the processing algorithm performance was achieved by minimizing the mean error of the heart rate after performing simultaneous comparative measurements on several subjects. In order to calculate the error the reference value of heart rate was measured using a classic measurement system through direct contact.
Jeon, Jin-Hun; Lee, Kyung-Tak; Kim, Hae-Young; Kim, Ji-Hwan
2013-01-01
PURPOSE The aim of this study was to evaluate the repeatability of the digitizing of silicon rubber impressions of abutment teeth by using a white light scanner and compare differences in repeatability between different abutment teeth types. MATERIALS AND METHODS Silicon rubber impressions of a canine, premolar, and molar tooth were each digitized 8 times using a white light scanner, and 3D surface models were created using the point clouds. The size of any discrepancy between each model and the corresponding reference tooth were measured, and the distribution of these values was analyzed by an inspection software (PowerInspect 2012, Delcamplc., Birmingham, UK). Absolute values of discrepancies were analyzed by the Kruskal-Wallis test and multiple comparisons (α=.05). RESULTS The discrepancy between the impressions for the canine, premolar, and molar teeth were 6.3 µm (95% confidence interval [CI], 5.4-7.2), 6.4 µm (95% CI, 5.3-7.6), and 8.9 µm (95% CI, 8.2-9.5), respectively. The discrepancy of the molar tooth impression was significantly higher than that of other tooth types. The largest variation (as mean [SD]) in discrepancies was seen in the premolar tooth impression scans: 26.7 µm (95% CI, 19.7-33.8); followed by canine and molar teeth impressions, 16.3 µm (95% CI, 15.3-17.3), and 14.0 µm (95% CI, 12.3-15.7), respectively. CONCLUSION The repeatability of the digitizing abutment teeth's silicon rubber impressions by using a white light scanner was improved compared to that with a laser scanner, showing only a low mean discrepancy between 6.3 µm and 8.9 µm, which was in an clinically acceptable range. Premolar impression with a long and narrow shape showed a significantly larger discrepancy than canine and molar impressions. Further work is needed to increase the digitizing performance of the white light scanner for deep and slender impressions. PMID:24353885
Flynn, Robert H.
2014-01-01
In addition to the two digital flood inundation maps, flood profiles were created that depict the study reach flood elevation of tropical storm Irene of August 2011 and the 10-, 2-, 1-, and 0.2-percent AEP floods, also known as the 10-, 50-, 100-, and 500-year floods, respectively. The 10-, 2-, 1-, and 0.2-percent AEP flood discharges were determined using annual peak flow data from the USGS Ottauquechee River near West Bridgewater, Vt. streamgage (station 01150900). Flood profiles were computed for the Ottauquechee River and Reservoir Brook by means of a one-dimensional step-backwater model. The model was calibrated using documented high-water marks of the peak of the tropical storm Irene flood of August 2011 as well as stage discharge data as determined for USGS Ottauquechee River near West Bridgewater, Vt. streamgage (station 01150900). The simulated water-surface profiles were combined with a digital elevation model within a geographic information system to delineate the areas flooded during tropical storm Irene and for the 1-percent AEP water-surface profile. The digital elevation model data were derived from light detection and ranging (lidar) data obtained for a 3,281-foot (1,000-meter) corridor along the Ottauquechee River study reach and were augmented with 33-foot (10- meter) contour interval data in the modeled flood-inundation areas outside the lidar corridor. The 33-foot (10-meter) contour interval USGS 15-minute quadrangle topographic digital raster graphics map used to augment lidar data was produced at a scale of 1:24,000. The digital flood inundation maps and flood profiles along with information regarding current stage from USGS streamgages on the Internet provide emergency management personnel and residents with information that is critical for flood response activities, such as evacuations and road closures, as well as for post-flood recovery efforts.
2014-01-01
Background Melanoma incidence is growing and more people require follow-up to detect recurrent melanoma quickly. Those detecting their own recurrent melanoma appear to have the best prognosis, so total skin self examination (TSSE) is advocated, but practice is suboptimal. A digital intervention to support TSSE has potential but it is not clear which patient groups could benefit most. The aim of this study was to explore cutaneous melanoma recurrence patterns between 1991 and 2012 in Northeast Scotland. The objectives were to: determine how recurrent melanomas were detected during the period; explore factors potentially predictive of mode of recurrence detection; identify groups least likely to detect their own recurrent melanoma and with most potential to benefit from digital TSSE support. Methods Pathology records were used to identify those with a potential recurrent melanoma of any type (local, regional and distant). Following screening of potential cases available secondary care-held records were subsequently scrutinised. Data was collected on demographics and clinical characteristics of the initial and recurrent melanoma. Data were handled in Microsoft Excel and transported into SPSS 20.0 for statistical analysis. Factors predicting detection at interval or scheduled follow-up were explored using univariate techniques, with potentially influential factors combined in a multivariate binary logistic model to adjust for confounding. Results 149 potential recurrences were identified from the pathology database held at Aberdeen Royal Infirmary. Reliable data could be obtained on 94 cases of recurrent melanoma of all types. 30 recurrences (31.9%) were found by doctors at follow-up, and 64 (68.1%) in the interval between visits, usually by the patient themselves. Melanoma recurrences of all types occurring within one-year were significantly more likely to be found at follow-up visits, and this remained so following adjustment for other factors that could be used to target digital TSSE support. Conclusions A digital intervention should be offered to all newly diagnosed patients. This group could benefit most from optimal TSSE practice. PMID:24612627
A simplified digital lock-in amplifier for the scanning grating spectrometer.
Wang, Jingru; Wang, Zhihong; Ji, Xufei; Liu, Jie; Liu, Guangda
2017-02-01
For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.
A novel method for electronic measurement and recording of surgical drain output.
van Duren, Bernard Hendrik; van Boxel, Gijsbert Isaac
2017-04-01
Surgical drains are used to collect and measure fluids (e.g. serous fluid, lymph, blood, etc.). The volume of fluid in the container is measured using graded markings on the container and then recorded manually on a "drain chart" allowing for manual rate calculations. This method is dependant on regularly checking the volume of the drain and recording the value accurately; unfortunately, this is often not feasible due to staffing levels and time constraints. This results in inaccurate "drain charts" making clinical decisions based on these figures unreliable. Often the lack of confidence in these measurements leads to delayed drain removal with consequent increased infection risks and potential delayed discharge. Accurate digital measurement of drain content would have a significant impact on clinical care. This paper describes a digital technology to measure volume, making use of a positive terminal at the lowest point of the vessel and negative (sensor) terminals placed at accurate intervals along an axis of the vessel. A proof-of-concept prototype was developed using commercially available electronic components to test the feasibility of a technology for electronic measurement and recording of surgical drain content. In a simulated environment, the proposed technology was shown to be effective and accurate. The proposed electronic drain has a number of advantages over currently used devices in saving time and easing pressure on nursing staff, reduce disturbance of patients, and allows for preset alarms.
Knapp, R.W.; Anderson, N.L.
1994-01-01
Data may be overprinted by a steady-state cyclical noise (hum). Steady-state indicates that the noise is invariant with time; its attributes, frequency, amplitude, and phase, do not change with time. Hum recorded on seismic data usually is powerline noise and associated higher harmonics; leakage from full-waveform rectified cathodic protection devices that contain the odd higher harmonics of powerline frequencies; or vibrational noise from mechanical devices. The fundamental frequency of powerline hum may be removed during data acquisition with the use of notch filters. Unfortunately, notch filters do not discriminate signal and noise, attenuating both. They also distort adjacent frequencies by phase shifting. Finally, they attenuate only the fundamental mode of the powerline noise; higher harmonics and frequencies other than that of powerlines are not removed. Digital notch filters, applied during processing, have many of the same problems as analog filters applied in the field. The method described here removes hum of a particular frequency. Hum attributes are measured by discrete Fourier analysis, and the hum is canceled from the data by subtraction. Errors are slight and the result of the presence of (random) noise in the window or asynchrony of the hum and data sampling. Error is minimized by increasing window size or by resampling to a finer interval. Errors affect the degree of hum attenuation, not the signal. The residual is steady-state hum of the same frequency. ?? 1994.
Tang, Jennifer Y-M; Wong, Gloria H-Y; Ng, Carmen K-M; Kwok, Dorothy T-S; Lee, Maggie N-Y; Dai, David L-K; Lum, Terry Y-S
2016-03-01
To examine the neuropsychological and clinical profile of help-seekers in an early-detection community dementia program and to explore any relationship between profiles and time to seek help. Cross-sectional. Early-detection community dementia program. Help-seekers (N = 1,005) with subjective cognitive complaints or complaints from an informant. Neurocognitive testing, including the Cantonese Mini-Mental State Examination (MMSE), Clock Drawing Test, Digit Span, and Fuld Object Memory Evaluation and other clinical and functioning assessments, including the Clinical Dementia Rating (CDR), activities of daily living (ADLs), instrumental ADLs (IADLs), and depressive symptoms. Time since the person or an informant reported that they first noticed symptoms. Eighty-six percent of help-seekers had at least very mild dementia (CDR score ≥0.5). Cognitive performance was moderately impaired (mean MMSE score 18.4 ± 6.1). They required some assistance with IADLs, had very mild ADL impairments, and had few depressive symptoms. Median time to seek assessment was 12 months (interquartile range 7-30 months) according to the person or the informant (an adult child in 75% of the sample). Using the median-split method, time to seek assessment was classified as early (0-12 months) and late (>12 months). Worse cognitive and IADL performance but not ADL performance or depressive symptoms were observed in late than in early help-seekers. Longer time intervals between symptom recognition and early assessment showed a trend of further impairments on all measures except ADLs. A time interval of more than 12 months between symptom recognition and early assessment appears to be associated with worse cognitive function upon presentation. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.
Hansmann, Jan; Morelli, John N; Michaely, Henrik J; Riester, Thomas; Budjan, Johannes; Schoenberg, Stefan O; Attenberger, Ulrike I
2014-06-01
To evaluate the diagnostic accuracy of a nonenhanced electrocardiograph-gated quiescent-interval single shot MR-angiography (QISS-MRA) at 3 Tesla with contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA) serving as reference standard. Following institutional review board approval, 16 consecutive patients with peripheral arterial disease underwent a combined peripheral MRA protocol consisting of a large field-of-view QISS-MRA, continuous table movement MRA, and an additional time-resolved MRA of the calves. DSA correlation was available in eight patients. Image quality and degree of stenosis was assessed. Sensitivity and specificity of QISS-MRA was evaluated with CE-MRA and DSA serving as the standards of reference and compared using the Fisher exact test. With the exception of the calf station, image quality with QISS-MRA was rated statistically significantly less than that of CE-MRA (P < 0.05, P = 0.17, and P = 0.6, respectively). A greater percentage of segments were not accessible with QISS-MRA (19.5-20.1%) in comparison to CE-MRA (10.9%). Relative to DSA, sensitivity for QISS-MRA was high (100% versus 91.2% for CE-MRA, P = 0.24) in the evaluated segments; however, specificity (76.5%) was substantially less than that of CE-MRA (94.6%, P = 0.003). Overall image quality and specificity of QISS-MRA at 3T are diminished relative to CE-MRA. However, when image quality is adequate, QISS-MRA has high sensitivity and, thus, has potential use in patients with contraindications to gadolinium. Copyright © 2013 Wiley Periodicals, Inc.
Electrocardiographic findings in patients with polycythemia vera.
Kayrak, Mehmet; Acar, Kadir; Gul, Enes Elvin; Abdulhalikov, Turyan; Bağlıcaklıoğlu, Murat; Sonmez, Osman; Kaya, Zeynettin; Arı, Hatem
2012-01-01
The 12-lead surface electrocardiogram (ECG) is a useful tool to predict both atrial and ventricular arrhythmias via P-wave and QT measurements and its derivatives. Polycythemia vera (PV) is a chronic myeloproliferative disorder associated with cardiovascular events. The aim of this study was to assess ECG findings of patients with PV. Sixty patients with PV (34 male, mean age 58±11 years) and 60 age and gender-matched healthy volunteers were enrolled into the study. From the 12-lead surface ECG, P-wave and both conventional QT measurements and transmyocardial repolarization parameters (T(peak)-T(end) interval (T(p)-T(e)) and derivatives) were evaluated digitally by two experienced cardiologists. In addition, a novel parameter, Pi was calculated digitally as the standard deviation of the P-wave duration across the 12 ECG leads. QT duration and corrected QT interval were significantly longer in the PV group compared to healthy controls (p<0.01 and p<0.01, respectively). The T(p)-T(e) was longer and the T(p)-T(e)/QT ratio was significantly higher in the PV group compared to the controls. P-wave analyses showed that all P-wave parameters including Pmax, Pmin, P dispersion, and Pi were significantly prolonged in PV patients compared to the controls. The increase of both T(p)-T(e )and P max in the PV group was independent of age, BMI, diabetes and hypertension, gender, systolic blood pressure, hemoglobin, hematocrit, left atrial dimension, left ventricular end-diastolic diameter and early deceleration time in a univariate analysis of co-variance model (F=11.097, p=0.001 and F=31.537, p=0.0001, respectively). The present study demonstrated that PV may be associated with electrocardiographic abnormalities of both atrium and ventricle.
Riber-Hansen, Rikke; Nyengaard, Jens R; Hamilton-Dutoit, Stephen J; Sjoegren, Pia; Steiniche, Torben
2011-09-01
Total metastatic volume (TMV) is an important prognostic factor in melanoma sentinel lymph nodes (SLNs) that avoids both the interobserver variation and unidirectional upstaging seen when using semi-quantitative size estimates. However, it is somewhat laborious for routine application. Our aim was to investigate whether digital image analysis can estimate TMV accurately in melanoma SLNs. TMV was measured in 147 SLNs from 95 patients both manually and by automated digital image analysis. The results were compared by Bland-Altman plots (numerical data) and kappa statistics (categorical data). In addition, disease-free and melanoma-specific survivals were calculated. Mean metastatic volume per patient was 10.6 mm(3) (median 0.05 mm(3); range 0.0001-621.3 mm(3)) and 9.62 mm(3) (median 0.05 mm(3); range 0.00001-564.3 mm(3)) with manual and digital measurement, respectively. The Bland-Altman plot showed an even distribution of the differences, and the kappa statistic was 0.84. In multivariate analysis, both manual and digital metastasis volume measurements were independent progression markers when corrected for primary tumour thickness [manual: hazard ratio (HR): 1.21, 95% confidence interval (CI): 1.07-1.36, P = 0.002; digital: HR: 1.21, 95% CI: 1.06-1.37, P = 0.004]. Stereology-based, automated digital metastasis volume measurement in melanoma SLNs predicts disease recurrence and survival. © 2011 Blackwell Publishing Limited.
Respiration and heart rate at the surface between dives in northern elephant seals.
Le Boeuf, B J; Crocker, D E; Grayson, J; Gedamke, J; Webb, P M; Blackwell, S B; Costa, D P
2000-11-01
All underwater activities of diving mammals are constrained by the need for surface gas exchange. Our aim was to measure respiratory rate (fb) and heart rate (fh) at the surface between dives in free-ranging northern elephant seals Mirounga angustirostris. We recorded fb and fh acoustically in six translocated juveniles, 1.8-2. 4 years old, and three migrating adult males from the rookery at Año Nuevo, California, USA. To each seal, we attached a diving instrument to record the diving pattern, a satellite tag to track movements and location, a digital audio tape recorder or acoustic datalogger with an external hydrophone to record the sounds of respiration and fh at the surface, and a VHF transmitter to facilitate recovery. During surface intervals averaging 2.2+/-0.4 min, adult males breathed a mean of 32.7+/-5.4 times at a rate of 15. 3+/-1.8 breaths min(-)(1) (means +/- s.d., N=57). Mean fh at the surface was 84+/-3 beats min(-)(1). The fb of juveniles was 26 % faster than that of adult males, averaging 19.2+/-2.2 breaths min(-)(1) for a mean total of 41.2+/-5.0 breaths during surface intervals lasting 2.6+/-0.31 min. Mean fh at the surface was 106+/-3 beats min(-)(1). fb and fh did not change significantly over the course of surface intervals. Surface fb and fh were not clearly associated with levels of exertion, such as rapid horizontal transit or apparent foraging, or with measures of immediately previous or subsequent diving performance, such as diving duration, diving depth or swimming speed. Together, surface respiration rate and the duration of the preceding dive were significant predictors of surface interval duration. This implies that elephant seals minimize surface time spent loading oxygen depending on rates of oxygen uptake and previous depletion of stores.
Wang, Lihan; Gan, John Q; Zhang, Li; Wang, Haixian
2018-06-01
Previous neuroimaging research investigating dissociation between single-digit addition and multiplication has suggested that the former placed more reliance on the visuo-spatial processing whereas the latter on the verbal processing. However, there has been little exploration into the disassociation in spatio-temporal dynamics of the oscillatory brain activity in specific frequency bands during the two arithmetic operations. To address this issue, the electroencephalogram (EEG) data were recorded from 19 participants engaged in a delayed verification arithmetic task. By analyzing oscillatory EEG activity in theta (5-7 Hz) and lower alpha frequency (9-10 Hz) bands, we found different patterns of oscillatory brain activity between single-digit addition and multiplication during the early processing stage (0-400 ms post-operand onset). Experiment results in this study showed a larger phasic increase of theta-band power for addition than for multiplication in the midline and the right frontal and central regions during the operator and operands presentation intervals, which was extended to the right parietal and the right occipito-temporal regions during the interval immediately after the operands presentation. In contrast, during multiplication higher phase-locking in lower alpha band was evident in the centro-parietal regions during the operator presentation, which was extended to the left fronto-central and anterior regions during the operands presentation. Besides, we found stronger theta phase synchrony between the parietal areas and the right occipital areas for single-digit addition than for multiplication during operands encoding. These findings of oscillatory brain activity extend the previous observations on functional dissociation between the two arithmetic operations. Copyright © 2018 Elsevier B.V. All rights reserved.
Hunsaker, Joshua J H; Wyness, Sara P; Snow, Taylor M; Genzen, Jonathan R
2016-12-01
Refractometric methods to measure total protein (TP) in serum and plasma specimens have been replaced by automated biuret methods in virtually all routine clinical testing. A subset of laboratories, however, still report using refractometry to measure TP in conjunction with serum protein electrophoresis. The objective of this study was therefore to conduct a modern performance evaluation of a digital refractometer for TP measurement. Performance evaluation of a MISCO Palm Abbe™ digital refractometer was conducted through device familiarization, carryover, precision, accuracy, linearity, analytical sensitivity, analytical specificity, and reference interval verification. Comparison assays included a manual refractometer and an automated biuret assay. Carryover risk was eliminated using a demineralized distilled water (ddH 2 O) wash step. Precision studies demonstrated overall imprecision of 2.2% CV (low TP pool) and 0.5% CV (high TP pool). Accuracy studies demonstrated correlation to both manual refractometry and the biuret method. An overall positive bias (+5.0%) was observed versus the biuret method. On average, outlier specimens had an increased triglyceride concentration. Linearity was verified using mixed dilutions of: a) low and high concentration patient pools, or b) albumin-spiked ddH 2 O and high concentration patient pool. Decreased recovery was observed using ddH 2 O dilutions at low TP concentrations. Significant interference was detected at high concentrations of glucose (>267 mg/dL) and triglycerides (>580 mg/dL). Current laboratory reference intervals for TP were verified. Performance characteristics of this digital refractometer were validated in a clinical laboratory setting. Biuret method remains the preferred assay for TP measurement in routine clinical analyses.
Ohashi, Ryoko; Nagao, Michinobu; Nakamura, Izumi; Okamoto, Takahiro; Sakai, Shuji
2018-04-12
The aim of this study was to determine if the diagnostic performance of breast lesion examinations could be improved using both digital breast tomosynthesis (DBT) and conventional digital mammography (CDM). Our institutional review board approved the protocol, and patients were provided the opportunity to opt out of the study. A total of 628 patients aged 22-91 years with abnormal screening results or clinical symptoms were consecutively enrolled between June 2015 and March 2016. All patients underwent DBT and CDM, and 1164 breasts were retrospectively analyzed by three radiologists who interpreted the results based on the Breast Imaging Reporting and Data System. Categories 4 and 5 were considered positive, and pathological results were the gold standard. The diagnostic performance of CDM and CDM plus DBT was compared using the mean areas under the receiver operating characteristic (ROC) curves. A total of 100 breast cancer cases were identified. The areas under the ROC curves were 0.9160 (95% confidence interval 0.8779-0.9541) for CDM alone and 0.9376 (95% confidence interval 0.9019-0.9733) for CDM plus DBT. The cut-off values for both CDM alone and CDM plus DBT measurements were 4, with sensitivities of 61.0% (61/100) and 83.0% (83/100), respectively, and specificities of 99.1% (1054/1064) and 98.9% (1052/1064), respectively. CDM yielded 39 false-negative diagnoses, while CDM plus DBT identified breast cancer in 22 of those cases (56.4%). The combination of DBT and CDM for the diagnosis of breast cancer in women with abnormal examination findings or clinical symptoms proved effective and should be used to improve the diagnostic performance of breast cancer examinations.
Signal digitizing system and method based on amplitude-to-time optical mapping
Chou, Jason; Bennett, Corey V; Hernandez, Vince
2015-01-13
A signal digitizing system and method based on analog-to-time optical mapping, optically maps amplitude information of an analog signal of interest first into wavelength information using an amplitude tunable filter (ATF) to impress spectral changes induced by the amplitude of the analog signal onto a carrier signal, i.e. a train of optical pulses, and next from wavelength information to temporal information using a dispersive element so that temporal information representing the amplitude information is encoded in the time domain in the carrier signal. Optical-to-electrical conversion of the optical pulses into voltage waveforms and subsequently digitizing the voltage waveforms into a digital image enables the temporal information to be resolved and quantized in the time domain. The digital image may them be digital signal processed to digitally reconstruct the analog signal based on the temporal information with high fidelity.
Luria, Isaac; Lampotang, Samsun; Schwab, Wilhelm; Cooper, Lou Ann; Lizdas, David; Gravenstein, Nikolaus
2013-11-01
The Low Flow Wizard (LFW) provides real-time guidance for user optimization of fresh gas flow (FGF) settings during general inhaled anesthesia. The LFW can continuously inform users whether it determines their FGF to be too little, efficient, or too much, and its color-coded recommendations respond in real time to changes in FGF performed by users. Our study objective was to determine whether the LFW feature, as implemented in the Dräger Apollo workstation, alters FGF selection and thereby volatile anesthetic consumption without affecting patient care. To reduce potentially confounding variables, we used a human patient simulator that consumes and exhales volatile anesthetics. Standard monitoring was provided for the patient initially with invasive arterial blood pressure added after anesthetic induction. In this within-group study, each of 17 participants acted as his or her own control. Each participant was asked to anesthetize an identical simulated patient twice using a Dräger Apollo workstation, first with the LFW feature disabled and subsequently enabled. The volatile anesthetic was isoflurane. Both simulation runs were set up to have similar time durations for the different phases of anesthesia: induction, incision, and maintenance. Emergence was not simulated. The isoflurane vaporizer was weighed before and after each simulation run on a digital scale to verify total computed volatile liquid anesthetic consumption. In addition, the product of FGF (reported by the Apollo) times the isoflurane volumetric concentration (sampled by a multigas analyzer at the equivalent of the FGF hose for the Apollo) was integrated over time to obtain isoflurane consumption rate (on-the-fly anesthetic consumption rate measurement). The maintenance isoflurane consumption rate and FGF were significantly lower with the LFW display enabled than without (P = 0.005). The mean reduction in FGF was 53.6% (95% confidence interval, 39.2%-67.9%). There was no significant difference in alveolar isoflurane concentration (P = 0.13 for differences <0.1%). The isoflurane consumption measurement closely matched the consumption measured via the digital scale. Our data in a simulated anesthetic suggest that enabling the display of FGF efficiency data by the LFW results in a median percent reduction in volatile liquid anesthetic consumption rate of 53.2%. Since the lower limit of the 95% confidence interval for the median is 39.4%, this finding is likely to translate into cost savings and less waste anesthetic gas generated in the clinical setting and released into the atmosphere.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement.
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-03-01
Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Photographs were found to have high reliability coefficient (P > 0.05). The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement.
Grundlingh, A A; Grossman, E S; Shrivastava, S; Witcomb, M J
2013-10-01
This study compared digital and visual colour tooth colour assessment methods in a sample of 99 teeth consisting of incisors, canines and pre-molars. The teeth were equally divided between Control, Ozicure Oxygen Activator bleach and Opalescence Quick bleach and subjected to three treatments. Colour readings were recorded at nine intervals by two assessment methods, VITA Easyshade and VITAPAN 3D MASTER TOOTH GUIDE, giving a total of 1782 colour readings. Descriptive and statistical analysis was undertaken using a GLM test for Analysis of Variance for a Fractional Design set at a significance of P < 0.05. Atomic force micros copy was used to examine treated ename surfaces and establish surface roughness. Visual tooth colour assessment showed significance for the independent variables of treatment, number of treatments, tooth type and the combination tooth type and treatment. Digital colour assessment indicated treatment and tooth type to be of significance in tooth colour change. Poor agreement was found between visual and digital colour assessment methods for Control and Ozicure Oxygen Activator treatments. Surface roughness values increased two-fold for Opalescence Quick specimens over the two other treatments, implying that increased light scattering improved digital colour reading. Both digital and visual colour matching methods should be used in tooth bleaching studies to complement each other and to compensate for deficiencies.
Kong, Jun; Li, Xiaoyan; Wang, Youdong; Sun, Wei; Zhang, Jinsong
2009-09-01
To assess the impact of digital problem-based learning (PBL) cases on student learning in ophthalmology courses. Ninety students were randomly divided into 3 classes (30 students per class). The first class studied under a didactic model. The other 2 classes were divided into 6 groups (10 students per group) and received PBL teaching; 3 groups studied via cases presented in digital form and the others studied via paper-form cases. The results of theoretical and case analysis examinations were analyzed using the chi(2) test. Student performance on the interval practice was analyzed using the Kruskal-Wallis test. Questionnaires were used to evaluate student and facilitator perceptions. Students in the digital groups exhibited better performance in the practice procedures according to tutorial evaluations compared with the other groups (P < .05). The 2 PBL classes had significantly higher mean results of theoretical and case analysis examinations (P < .001), but there was no significant difference between the 2 PBL classes. Ninety-three percent of students in the digital groups (vs 73% in the paper groups) noted that the cases greatly stimulated their interest. Introducing PBL into ophthalmology could improve educational quality and effectiveness. Digital PBL cases stimulate interest and motivate students to further improve diagnosis and problem-handling skills.
A Neutron Burst Associated with an Extensive Air Shower?
NASA Astrophysics Data System (ADS)
Alves, Mauro; Martin, Inacio; Shkevov, Rumen; Gusev, Anatoly; De Abreu, Alessandro
2016-07-01
A portable and compact system based on a He-3 tube (LND, USA; model 25311) with an area of approximately 250 cm² and is used to record neutron count rates at ground level in the energy range of 0.025 eV to 10 MeV, in São José dos Campos, SP, Brazil (23° 12' 45" S, 45° 52' 00" W; altitude, 660m). The detector, power supply, digitizer and other hardware are housed in an air-conditioned room. The detector power supply and digitizer are not connected to the main electricity network; a high-capacity 12-V battery is used to power the detector and digitizer. Neutron counts are accumulated at 1-minute intervals continuously. The data are stored in a PC for further analysis. In February 8, 2015, at 12 h 22 min (local time) during a period of fair weather with minimal cloud cover (< 1 okta) the neutron detector recorded a sharp (count rate = 27 neutrons/min) and brief (< 1 min) increase in the count rate. In the days before and after this event, the neutron count rate has oscillated between 0 and 3 neutrons/min. Since the occurrence of this event is not related with spurious signals, malfunctioning equipment, oscillations in the mains voltage, etc. we are led to believe that the sharp increase was caused by a physical source such as a an extensive air shower that occurred over the detector.
Eustachian Tube Mucosal Inflammation Scale Validation Based on Digital Video Images.
Kivekäs, Ilkka; Pöyhönen, Leena; Aarnisalo, Antti; Rautiainen, Markus; Poe, Dennis
2015-12-01
The most common cause for Eustachian tube dilatory dysfunction is mucosal inflammation. The aim of this study was to validate a scale for Eustachian tube mucosal inflammation, based on digital video clips obtained during diagnostic rigid endoscopy. A previously described four-step scale for grading the degree of inflammation of the mucosa of the Eustachian tube lumen was used for this validation study. A tutorial for use of the scale, including static images and 10 second video clips, was presented to 26 clinicians with various levels of experience. Each clinician then reviewed 35 short digital video samples of Eustachian tubes from patients and rated the degree of inflammation. A subset of the clinicians performed a second rating of the same video clips at a subsequent time. Statistical analysis of the ratings provided inter- and intrarater reliability scores. Twenty-six clinicians with various levels of experience rated a total of 35 videos. Thirteen clinicians rated the videos twice. The overall correlation coefficient for the rating of inflammation severity was relatively good (0.74, 95% confidence interval, 0.72-0.76). The intralevel correlation coefficient for intrarater reliability was high (0.86). For those who rated videos twice, the intralevel correlation coefficient improved after the first rating (0.73, to 0.76), but improvement was not statistically significant. The inflammation scale used for Eustachian tube mucosal inflammation is reliable and this scale can be used with a high level of consistency by clinicians with various levels of experience.
NASA Astrophysics Data System (ADS)
Bogiatzis, P.; Altoé, I. L.; Karamitrou, A.; Ishii, M.; Ishii, H.
2015-12-01
DigitSeis is a new open-source, interactive digitization software written in MATLAB that converts digital, raster images of analog seismograms to readily usable, discretized time series using image processing algorithms. DigitSeis automatically identifies and corrects for various geometrical distortions of seismogram images that are acquired through the original recording, storage, and scanning procedures. With human supervision, the software further identifies and classifies important features such as time marks and notes, corrects time-mark offsets from the main trace, and digitizes the combined trace with an analysis to obtain as accurate timing as possible. Although a large effort has been made to minimize the human input, DigitSeis provides interactive tools for challenging situations such as trace crossings and stains in the paper. The effectiveness of the software is demonstrated with the digitization of seismograms that are over half a century old from the Harvard-Adam Dziewoński observatory that is still in operation as a part of the Global Seismographic Network (station code HRV and network code IU). The spectral analysis of the digitized time series shows no spurious features that may be related to the occurrence of minute and hour marks. They also display signals associated with significant earthquakes, and a comparison of the spectrograms with modern recordings reveals similarities in the background noise.
Fidler, Samantha; D’Orsogna, Lloyd; Irish, Ashley B.; Lewis, Joshua R.; Wong, Germaine; Lim, Wai H.
2018-01-01
Structural human leukocyte antigen (HLA) matching at the eplet level can be identified by HLAMatchmaker, which requires the entry of four-digit alleles. The aim of this study was to evaluate the agreement between eplet mismatches calculated by serological and two-digit typing methods compared to high-resolution four-digit typing. In a cohort of 264 donor/recipient pairs, the evaluation of measurement error was assessed using intra-class correlation to confirm the absolute agreement between the number of eplet mismatches at class I (HLA-A, -B, C) and II loci (HLA-DQ and -DR) calculated using serological or two-digit molecular typing compared to four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches between the HLA typing methods was also determined. Intra-class correlation coefficients between serological and four-digit molecular typing methods were 0.969 (95% confidence intervals [95% CI] 0.960–0.975) and 0.926 (95% CI 0.899–0.944), respectively; and 0.995 (95% CI 0.994–0.996) and 0.993 (95% CI 0.991–0.995), respectively between two-digit and four-digit molecular typing methods. The proportion of donor/recipient pairs with a difference of >5 eplet mismatches at class I and II loci was 4% and 16% for serological versus four-digit molecular typing methods, and 0% and 2% for two-digit versus four-digit molecular typing methods, respectively. In this small predominantly Caucasian population, compared with serology, there is a high level of agreement in the number of eplet mismatches calculated using two-compared to four-digit molecular HLA-typing methods, suggesting that two-digit typing may be sufficient in determining eplet mismatch load in kidney transplantation. PMID:29568344
Novel Tool for Complete Digitization of Paper Electrocardiography Data.
Ravichandran, Lakshminarayan; Harless, Chris; Shah, Amit J; Wick, Carson A; Mcclellan, James H; Tridandapani, Srini
We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. The validation demonstrates a correlation value of 0.85-0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8-0.9 (p < 0.05), and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record.
NASA Astrophysics Data System (ADS)
Tolle, F.; Friedt, J. M.; Bernard, É.; Prokop, A.; Griselin, M.
2014-12-01
Digital Elevation Model (DEM) is a key tool for analyzing spatially dependent processes including snow accumulation on slopes or glacier mass balance. Acquiring DEM within short time intervals provides new opportunities to evaluate such phenomena at the daily to seasonal rates.DEMs are usually generated from satellite imagery, aerial photography, airborne and ground-based LiDAR, and GPS surveys. In addition to these classical methods, we consider another alternative for periodic DEM acquisition with lower logistics requirements: digital processing of ground based, oblique view digital photography. Such a dataset, acquired using commercial off the shelf cameras, provides the source for generating elevation models using Structure from Motion (SfM) algorithms. Sets of pictures of a same structure but taken from various points of view are acquired. Selected features are identified on the images and allow for the reconstruction of the three-dimensional (3D) point cloud after computing the camera positions and optical properties. This cloud point, generated in an arbitrary coordinate system, is converted to an absolute coordinate system either by adding constraints of Ground Control Points (GCP), or including the (GPS) position of the cameras in the processing chain. We selected the opensource digital signal processing library provided by the French Geographic Institute (IGN) called Micmac for its fine processing granularity and the ability to assess the quality of each processing step.Although operating in snow covered environments appears challenging due to the lack of relevant features, we observed that enough reference points could be identified for 3D reconstruction. Despite poor climatic environment of the Arctic region considered (Ny Alesund area, 79oN) is not a problem for SfM, the low lying spring sun and the cast shadows appear as a limitation because of the lack of color dynamics in the digital cameras we used. A detailed understanding of the processing steps is mandatory during the image acquisition phase: compliance with acquisition rules reducing digital processing errors helps minimizing the uncertainty on the point cloud absolute position in its coordinate system. 3D models from SfM are compared with terrestrial LiDAR acquisitions for resolution assesment.
van de Pol, Daan; Zacharian, Tigran; Maas, Mario; Kuijer, P Paul F M
2017-06-01
The Shoulder posterior circumflex humeral artery Pathology and digital Ischemia - questionnaire (SPI-Q) has been developed to enable periodic surveillance of elite volleyball players, who are at risk for digital ischemia. Prior to implementation, assessing reliability is mandatory. Therefore, the test-retest reliability and agreement of the SPI-Q were evaluated among the population at risk. A questionnaire survey was performed with a 2-week interval among 65 elite male volleyball players assessing symptoms of cold, pale and blue digits in the dominant hand during or after practice or competition using a 4-point Likert scale (never, sometimes, often and always). Kappa (κ) and percentage of agreement (POA) were calculated for individual symptoms, and to distinguish symptomatic and asymptomatic players. For the individual symptoms, κ ranged from "poor" (0.25) to "good" (0.63), and POA ranged from "moderate" (78%) to "good" (97%). To classify symptomatic players, the SPI-Q showed "good" reliability (κ = 0.83; 95%CI 0.69-0.97) and "good" agreement (POA = 92%). The current study has proven the SPI-Q to be reliable for detecting elite male indoor volleyball players with symptoms of digital ischemia.
Historical analysis and visualization of the retreat of Findelengletscher, Switzerland, 1859-2010
NASA Astrophysics Data System (ADS)
Rastner, P.; Joerg, P. C.; Huss, M.; Zemp, M.
2016-10-01
Since the end of the Little Ice Age around 1850, glaciers in Europe have strongly retreated. Thanks to early topographic surveys in Switzerland, accurate maps are available, which enable us to trace glacier changes back in time. The earliest map for all of Switzerland that is usable for a detailed analysis is the Dufour map from around 1850 with subsequent topographic maps on a 20 year interval. Despite the large public and scientific interest in glacier changes through time, this historic dataset has not yet been fully utilized for topographic change assessment or visualization of historic glacier extents. In this study, we use eleven historical topographic maps and more recent digital datasets for the region of Zermatt to analyze geometric changes (length, area and volume) of Findelengletscher as well as for creating animations of glacier evolution through time for use in public communication. All maps were georeferenced, the contour lines digitized, and digital elevation models (DEMs) created and co-registered. Additional digital data like the SRTM X-band DEM and high resolution laser scanning data were used to extend the analysis until 2010. Moreover, one independent DEM from aerial photogrammetry was used for comparison. During the period 1859-2010, Findelengletscher lost 3.5 km of its length (6.9 km in 2010), 4.42 ± 0.13 km2 of its area (15.05 ± 0.45 km2 in 2010) and 1.32 ± 0.52 km3 of its volume. The average rate of thickness loss is 0.45 ± 0.042 m yr- 1 for the 151 years period. Four periods with high thickness change from - 0.56 m ± 0.28 yr- 1 (1859-1881), - 0.40 ± 0.08 m yr- 1 (1937-1965), - 0.90 ± 0.31 m yr- 1 (1995-2000) and - 1.18 ± 0.02 m yr- 1 (2000-2005) have been identified. Small positive thickness changes were found for the periods 1890-1909 (+ 0.09 ± 0.46 m yr- 1) and 1988-1995 (+ 0.05 ± 0.24 m yr- 1). During its retreat with intermittent periods of advance, the glacier separated into three parts. The above changes are demonstrated through an animation (available from the supplementary material), which has been created to inform the general public.
Digitized synchronous demodulator
NASA Technical Reports Server (NTRS)
Woodhouse, Christopher E. (Inventor)
1990-01-01
A digitized synchronous demodulator is constructed entirely of digital components including timing logic, an accumulator, and means to digitally filter the digital output signal. Indirectly, it accepts, at its input, periodic analog signals which are converted to digital signals by traditional analog-to-digital conversion techniques. Broadly, the input digital signals are summed to one of two registers within an accumulator, based on the phase of the input signal and medicated by timing logic. At the end of a predetermined number of cycles of the inputted periodic signals, the contents of the register that accumulated samples from the negative half cycle is subtracted from the accumulated samples from the positive half cycle. The resulting difference is an accurate measurement of the narrow band amplitude of the periodic input signal during the measurement period. This measurement will not include error sources encountered in prior art synchronous demodulators using analog techniques such as offsets, charge injection errors, temperature drift, switching transients, settling time, analog to digital converter missing code, and linearity errors.
Performance of preproduction model cesium beam frequency standards for spacecraft applications
NASA Technical Reports Server (NTRS)
Levine, M. W.
1978-01-01
A cesium beam frequency standards for spaceflight application on Navigation Development Satellites was designed and fabricated and preliminary testing was completed. The cesium standard evolved from an earlier prototype model launched aboard NTS-2 and the engineering development model to be launched aboard NTS satellites during 1979. A number of design innovations, including a hybrid analog/digital integrator and the replacement of analog filters and phase detectors by clocked digital sampling techniques are discussed. Thermal and thermal-vacuum testing was concluded and test data are presented. Stability data for 10 to 10,000 seconds averaging interval, measured under laboratory conditions, are shown.
Nazi, Kim M; Hibbard, Judith H; Houston, Thomas K
2017-01-01
Background As electronic health records and computerized workflows expand, there are unprecedented opportunities to digitally connect with patients using secure portals. To realize the value of patient portals, initial reach across populations will need to be demonstrated, as well as sustained usage over time. Objective The study aim was to identify patient factors associated with short-term and long-term portal usage after patients registered to access all portal functions. Methods We prospectively followed a cohort of patients at a large Department of Veterans Affairs (VA) health care facility who recently completed identity proofing to use the VA patient portal. Information collected at baseline encompassed patient factors potentially associated with portal usage, including: demographics, Internet access and use, health literacy, patient activation, and self-reported health conditions. The primary outcome was the frequency of portal log-ins during 6-month and 18-month time intervals after study enrollment. Results A total of 270 study participants were followed prospectively. Almost all participants (260/268, 97.0%) reported going online, typically at home (248/268, 92.5%). At 6 months, 84.1% (227/270) of participants had visited the portal, with some variation in usage across demographic and health-related subgroups. There were no significant differences in portal log-ins by age, gender, education, marital status, race/ethnicity, distance to a VA facility, or patient activation measure. Significantly higher portal usage was seen among participants using high-speed broadband at home, greater self-reported ability using the Internet, and routinely going online. By 18 months, 91% participants had logged in to the portal, and no significant associations were found between usage and demographics, health status, or patient activation. When examining portal activity between 6 and 18 months, patients who were infrequent or high portal users remained in those categories, respectively. Conclusions Short-term and long-term portal usage was associated with having broadband at home, high self-rated ability when using the Internet, and overall online behavior. Digital inclusion, or ready access to the Internet and digital skills, appears to be a social determinant in patient exposure to portal services. PMID:29042345
A model for a PC-based, universal-format, multimedia digitization system: moving beyond the scanner.
McEachen, James C; Cusack, Thomas J; McEachen, John C
2003-08-01
Digitizing images for use in case presentations based on hardcopy films, slides, photographs, negatives, books, and videos can present a challenging task. Scanners and digital cameras have become standard tools of the trade. Unfortunately, use of these devices to digitize multiple images in many different media formats can be a time-consuming and in some cases unachievable process. The authors' goal was to create a PC-based solution for digitizing multiple media formats in a timely fashion while maintaining adequate image presentation quality. The authors' PC-based solution makes use of off-the-shelf hardware applications to include a digital document camera (DDC), VHS video player, and video-editing kit. With the assistance of five staff radiologists, the authors examined the quality of multiple image types digitized with this equipment. The authors also quantified the speed of digitization of various types of media using the DDC and video-editing kit. With regard to image quality, the five staff radiologists rated the digitized angiography, CT, and MR images as adequate to excellent for use in teaching files and case presentations. With regard to digitized plain films, the average rating was adequate. As for performance, the authors recognized a 68% improvement in the time required to digitize hardcopy films using the DDC instead of a professional quality scanner. The PC-based solution provides a means for digitizing multiple images from many different types of media in a timely fashion while maintaining adequate image presentation quality.
Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A
1994-01-01
In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.
Multi-channel time-reversal receivers for multi and 1-bit implementations
Candy, James V.; Chambers, David H.; Guidry, Brian L.; Poggio, Andrew J.; Robbins, Christopher L.
2008-12-09
A communication system for transmitting a signal through a channel medium comprising digitizing the signal, time-reversing the digitized signal, and transmitting the signal through the channel medium. In one embodiment a transmitter is adapted to transmit the signal, a multiplicity of receivers are adapted to receive the signal, a digitizer digitizes the signal, and a time-reversal signal processor is adapted to time-reverse the digitized signal. An embodiment of the present invention includes multi bit implementations. Another embodiment of the present invention includes 1-bit implementations. Another embodiment of the present invention includes a multiplicity of receivers used in the step of transmitting the signal through the channel medium.
Newcombe, David A L; Somogyi, Andrew A; Bochner, Felix; White, Jason M
2017-06-01
Tolerance to the psychomotor impairing effects of opioid drugs is expected to develop with repeated dosing, but may be incomplete. The relationship between plasma opioid concentration and psychomotor function in opioid-dependent patients was examined to determine whether impairment was more likely at the time of highest plasma drug concentration. Sixteen patients participating in a cross-over trial comparing methadone and LAAM completed a tracking task (OSPAT) 11 times over the dosing-interval for methadone (24-hrs) and LAAM (48-hrs). Venous blood was collected for the quantification of plasma (R)-(-)-methadone, LAAM, and nor-LAAM concentrations. The Digit Symbol Substitution Test (DSST) and Trail-Making Test were administered at the time of peak plasma concentration. Ten healthy controls (HCs) also participated. OSPAT scores (obtained for 15 patients) fluctuated significantly across the dosing-interval for both drugs and were lower in patients than HCs at the times of peak concentrations of (R)-(-)-methadone (1 hr: (mean difference; 95% CI) (2.13; 0.18-4.08); 2 hrs: (2.38; 0.48-4.28) postdosing) and LAAM (2 hrs: (1.81; 0.09-3.53), and 4 hrs (1.90: 0.9-3.71) postdosing). Within-participant analysis of the peak-change from baseline for OSPAT scores found that 10 of the 15 patients could be categorized as impaired on methadone and 9 on LAAM. No HCs were impaired. Patients performed worse on the DSST and Trails-A than HCs, but not on Trails-B. Results suggest that some patients receiving opioids long term may exhibit impairment at the time of highest plasma drug concentration. These patients should be made aware that their ability to undertake complex tasks may be affected. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Axial Tomography from Digitized Real Time Radiography
DOE R&D Accomplishments Database
Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.
1985-01-18
Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.
Satellite mapping of Nile Delta coastal changes
NASA Technical Reports Server (NTRS)
Blodget, H. W.; Taylor, P. T.; Roark, J. H.
1989-01-01
Multitemporal, multispectral scanner (MSS) landsat data have been used to monitor erosion and sedimentation along the Rosetta Promontory of the Nile Delta. These processes have accelerated significantly since the completion of the Aswan High Dam in 1964. Digital differencing of four MSS data sets, using standard algorithms, show that changes observed over a single year period generally occur as strings of single mixed pixels along the coast. Therefore, these can only be used qualitatively to indicate areas where changes occur. Areas of change recorded over a multi-year period are generally larger and thus identified by clusters of pixels; this reduces errors introduced by mixed pixels. Satellites provide a synoptic perspective utilizing data acquired at frequent time intervals. This permits multiple year monitoring of delta evolution on a regional scale.
Biondich, Paul G; Overhage, J Marc; Dexter, Paul R; Downs, Stephen M; Lemmon, Larry; McDonald, Clement J
2002-01-01
Advances in optical character recognition (OCR) software and computer hardware have stimulated a reevaluation of the technology and its ability to capture structured clinical data from preexisting paper forms. In our pilot evaluation, we measured the accuracy and feasibility of capturing vitals data from a pediatric encounter form that has been in use for over twenty years. We found that the software had a digit recognition rate of 92.4% (95% confidence interval: 91.6 to 93.2) overall. More importantly, this system was approximately three times as fast as our existing method of data entry. These preliminary results suggest that with further refinements in the approach and additional development, we may be able to incorporate OCR as another method for capturing structured clinical data.
Digital Timing Recovery for High Speed Optical Drives
NASA Astrophysics Data System (ADS)
Ko, Seok Jun; Kim, Pan Soo; Choi, Hyung Jin; Lee, Jae-Wook
2002-03-01
A new digital timing recovery scheme for the optical drive system is presented. By comparative simulations using digital versatile disc (DVD) patterns with marginal input conditions, the proposed algorithm shows enhanced performances in jitter variance and signal-to-noise ratio (SNR) margin by four times and 3 [dB], respectively.
The Necessity of Real-Time: Fact and Fiction in Digital Reference Systems.
ERIC Educational Resources Information Center
Lankes, R. David; Shostack, Pauline
2002-01-01
Discussion of digital reference services and the use of real-time versus asynchronous services such as email focuses on data from the AskERIC digital reference service to demonstrate that asynchronous services are not only useful but may have greater utility than real-time systems. (Author/LRW)
Mirham, Lorna; Naugler, Christopher; Hayes, Malcolm; Ismiil, Nadia; Belisle, Annie; Sade, Shachar; Streutker, Catherine; MacMillan, Christina; Rasty, Golnar; Popovic, Snezana; Joseph, Mariamma; Gabril, Manal; Barnes, Penny; Hegele, Richard G.; Carter, Beverley; Yousef, George M.
2016-01-01
Background: It is anticipated that many licensing examination centres for pathology will begin fully digitizing the certification examinations. The objective of our study was to test the feasibility of a fully digital examination and to assess the needs, concerns and expectations of pathology residents in moving from a glass slide-based examination to a fully digital examination. Methods: We conducted a mixed methods study that compared, after randomization, the performance of senior residents (postgraduate years 4 and 5) in 7 accredited anatomical pathology training programs across Canada on a pathology examination using either glass slides or digital whole-slide scanned images of the slides. The pilot examination was followed by a post-test survey. In addition, pathology residents from all levels of training were invited to participate in an online survey. Results: A total of 100 residents participated in the pilot examination; 49 were given glass slides instead of digital images. We found no significant difference in examination results between the 2 groups of residents (estimated marginal mean 8.23/12, 95% confidence interval [CI] 7.72-8.87, for glass slides; 7.84/12, 95% CI 7.28-8.41, for digital slides). In the post-test survey, most of the respondents expressed concerns with the digital examination, including slowly functioning software, blurring and poor detail of images, particularly nuclear features. All of the respondents of the general survey (n = 179) agreed that additional training was required if the examination were to become fully digital. Interpretation: Although the performance of residents completing pathology examinations with glass slides was comparable to that of residents using digital images, our study showed that residents were not comfortable with the digital technology, especially given their current level of exposure to it. Additional training may be needed before implementing a fully digital examination, with consideration for a gradual transition. PMID:27280119
Using compressed images in multimedia education
NASA Astrophysics Data System (ADS)
Guy, William L.; Hefner, Lance V.
1996-04-01
The classic radiologic teaching file consists of hundreds, if not thousands, of films of various ages, housed in paper jackets with brief descriptions written on the jackets. The development of a good teaching file has been both time consuming and voluminous. Also, any radiograph to be copied was unavailable during the reproduction interval, inconveniencing other medical professionals needing to view the images at that time. These factors hinder motivation to copy films of interest. If a busy radiologist already has an adequate example of a radiological manifestation, it is unlikely that he or she will exert the effort to make a copy of another similar image even if a better example comes along. Digitized radiographs stored on CD-ROM offer marked improvement over the copied film teaching files. Our institution has several laser digitizers which are used to rapidly scan radiographs and produce high quality digital images which can then be converted into standard microcomputer (IBM, Mac, etc.) image format. These images can be stored on floppy disks, hard drives, rewritable optical disks, recordable CD-ROM disks, or removable cartridge media. Most hospital computer information systems include radiology reports in their database. We demonstrate that the reports for the images included in the users teaching file can be copied and stored on the same storage media as the images. The radiographic or sonographic image and the corresponding dictated report can then be 'linked' together. The description of the finding or findings of interest on the digitized image is thus electronically tethered to the image. This obviates the need to write much additional detail concerning the radiograph, saving time. In addition, the text on this disk can be indexed such that all files with user specified features can be instantly retrieve and combined in a single report, if desired. With the use of newer image compression techniques, hundreds of cases may be stored on a single CD-ROM depending on the quality of image required for the finding in question. This reduces the weight of a teaching file from that of a baby elephant to that of a single CD-ROM disc. Thus, with this method of teaching file preparation and storage the following advantages are realized: (1) Technically easier and less time consuming image reproduction. (2) Considerably less unwieldy and substantially more portable teaching files. (3) Novel ability to index files and then retrieve specific cases of choice based on descriptive text.
Input-output characterization of an ultrasonic testing system by digital signal analysis
NASA Technical Reports Server (NTRS)
Williams, J. H., Jr.; Lee, S. S.; Karagulle, H.
1986-01-01
Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.
Huang, Sha; Deshpande, Aadya; Yeo, Sing-Chen; Lo, June C.; Chee, Michael W.L.; Gooley, Joshua J.
2016-01-01
Study Objectives: The ability to recall facts is improved when learning takes place at spaced intervals, or when sleep follows shortly after learning. However, many students cram for exams and trade sleep for other activities. The aim of this study was to examine the interaction of study spacing and time in bed (TIB) for sleep on vocabulary learning in adolescents. Methods: In the Need for Sleep Study, which used a parallel-group design, 56 adolescents aged 15–19 years were randomly assigned to a week of either 5 h or 9 h of TIB for sleep each night as part of a 14-day protocol conducted at a boarding school. During the sleep manipulation period, participants studied 40 Graduate Record Examination (GRE)-type English words using digital flashcards. Word pairs were presented over 4 consecutive days (spaced items), or all at once during single study sessions (massed items), with total study time kept constant across conditions. Recall performance was examined 0 h, 24 h, and 120 h after all items were studied. Results: For all retention intervals examined, recall of massed items was impaired by a greater amount in adolescents exposed to sleep restriction. In contrast, cued recall performance on spaced items was similar between sleep groups. Conclusions: Spaced learning conferred strong protection against the effects of sleep restriction on recall performance, whereas students who had insufficient sleep were more likely to forget items studied over short time intervals. These findings in adolescents demonstrate the importance of combining good study habits and good sleep habits to optimize learning outcomes. Citation: Huang S, Deshpande A, Yeo SC, Lo JC, Chee MW, Gooley JJ. Sleep restriction impairs vocabulary learning when adolescents cram for exams: the Need for Sleep Study. SLEEP 2016;39(9):1681–1690. PMID:27253768
Digital Bathymetric Model of Mono Lake, California
Raumann, Christian G.; Stine, Scott; Evans, Alexander; Wilson, Jerry
2002-01-01
In 1986 and 1987, Pelagos Corporation of San Diego (now Racal Pelagos) undertook a bathymetric survey of Mono Lake in eastern California for the Los Angeles Department of Water and Power (DWP). The result of that survey was a series of maps at various scales and contour intervals. From these maps, the DWP hoped to predict consequences of the drop in lake level that resulted from their diversion of streams in the Mono Basin. No digital models, including shaded-relief and perspective-view renderings, were made from the data collected during the survey. With the permission of Pelagos Corporation and DWP, these data are used to produce a digital model of the floor of Mono Lake. The model was created using a geographic information system (GIS) to incorporate these data with new observations and measurements made in the field. This model should prove to be a valuable tool for enhanced visualization and analyses of the floor of Mono Lake.
Computerized Analysis of Digital Photographs for Evaluation of Tooth Movement
Toodehzaeim, Mohammad Hossein; Karandish, Maryam; Karandish, Mohammad Nabi
2015-01-01
Objectives: Various methods have been introduced for evaluation of tooth movement in orthodontics. The challenge is to adopt the most accurate and most beneficial method for patients. This study was designed to introduce analysis of digital photographs with AutoCAD software as a method to evaluate tooth movement and assess the reliability of this method. Materials and Methods: Eighteen patients were evaluated in this study. Three intraoral digital images from the buccal view were captured from each patient in half an hour interval. All the photos were sent to AutoCAD software 2011, calibrated and the distance between canine and molar hooks were measured. The data was analyzed using intraclass correlation coefficient. Results: Photographs were found to have high reliability coefficient (P > 0.05). Conclusion: The introduced method is an accurate, efficient and reliable method for evaluation of tooth movement. PMID:26622272
ERIC Educational Resources Information Center
Grimley, Mick
2012-01-01
Recent developments in digital technology have resulted in the unprecedented uptake of digital technology engagement as a leisure-time pursuit across the age span. This has resulted in the speculation that such use of digital technology is responsible for changes in cognition and learning behaviour. This study investigated two groups of…
Enhancing surgical safety using digital multimedia technology.
Dixon, Jennifer L; Mukhopadhyay, Dhriti; Hunt, Justin; Jupiter, Daniel; Smythe, William R; Papaconstantinou, Harry T
2016-06-01
The purpose of this study was to examine whether incorporating digital and video multimedia components improved surgical time-out performance of a surgical safety checklist. A prospective pilot study was designed for implementation of a multimedia time-out, including a patient video. Perceptions of the staff participants were surveyed before and after intervention (Likert scale: 1, strongly disagree to 5, strongly agree). Employee satisfaction was high for both time-out procedures. However, employees appreciated improved clarity of patient identification (P < .05) and operative laterality (P < .05) with the digital method. About 87% of the respondents preferred the digital version to the standard time-out (75% anesthesia, 89% surgeons, 93% nursing). Although the duration of time-outs increased (49 and 79 seconds for standard and digital time-outs, respectively, P > .001), there was significant improvement in performance of key safety elements. The multimedia time-out allows improved participation by the surgical team and is preferred to a standard time-out process. Copyright © 2015 Elsevier Inc. All rights reserved.
Instrument for Real-Time Digital Nucleic Acid Amplification on Custom Microfluidic Devices
Selck, David A.
2016-01-01
Nucleic acid amplification tests that are coupled with a digital readout enable the absolute quantification of single molecules, even at ultralow concentrations. Digital methods are robust, versatile and compatible with many amplification chemistries including isothermal amplification, making them particularly invaluable to assays that require sensitive detection, such as the quantification of viral load in occult infections or detection of sparse amounts of DNA from forensic samples. A number of microfluidic platforms are being developed for carrying out digital amplification. However, the mechanistic investigation and optimization of digital assays has been limited by the lack of real-time kinetic information about which factors affect the digital efficiency and analytical sensitivity of a reaction. Commercially available instruments that are capable of tracking digital reactions in real-time are restricted to only a small number of device types and sample-preparation strategies. Thus, most researchers who wish to develop, study, or optimize digital assays rely on the rate of the amplification reaction when performed in a bulk experiment, which is now recognized as an unreliable predictor of digital efficiency. To expand our ability to study how digital reactions proceed in real-time and enable us to optimize both the digital efficiency and analytical sensitivity of digital assays, we built a custom large-format digital real-time amplification instrument that can accommodate a wide variety of devices, amplification chemistries and sample-handling conditions. Herein, we validate this instrument, we provide detailed schematics that will enable others to build their own custom instruments, and we include a complete custom software suite to collect and analyze the data retrieved from the instrument. We believe assay optimizations enabled by this instrument will improve the current limits of nucleic acid detection and quantification, improving our fundamental understanding of single-molecule reactions and providing advancements in practical applications such as medical diagnostics, forensics and environmental sampling. PMID:27760148
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dise, J; Liang, X; Lin, L
Purpose: To evaluate an automatic interstitial catheter digitization algorithm that reduces treatment planning time and provide means for adaptive re-planning in HDR Brachytherapy of Gynecologic Cancers. Methods: The semi-automatic catheter digitization tool utilizes a region growing algorithm in conjunction with a spline model of the catheters. The CT images were first pre-processed to enhance the contrast between the catheters and soft tissue. Several seed locations were selected in each catheter for the region growing algorithm. The spline model of the catheters assisted in the region growing by preventing inter-catheter cross-over caused by air or metal artifacts. Source dwell positions frommore » day one CT scans were applied to subsequent CTs and forward calculated using the automatically digitized catheter positions. This method was applied to 10 patients who had received HDR interstitial brachytherapy on an IRB approved image-guided radiation therapy protocol. The prescribed dose was 18.75 or 20 Gy delivered in 5 fractions, twice daily, over 3 consecutive days. Dosimetric comparisons were made between automatic and manual digitization on day two CTs. Results: The region growing algorithm, assisted by the spline model of the catheters, was able to digitize all catheters. The difference between automatic and manually digitized positions was 0.8±0.3 mm. The digitization time ranged from 34 minutes to 43 minutes with a mean digitization time of 37 minutes. The bulk of the time was spent on manual selection of initial seed positions and spline parameter adjustments. There was no significance difference in dosimetric parameters between the automatic and manually digitized plans. D90% to the CTV was 91.5±4.4% for the manual digitization versus 91.4±4.4% for the automatic digitization (p=0.56). Conclusion: A region growing algorithm was developed to semi-automatically digitize interstitial catheters in HDR brachytherapy using the Syed-Neblett template. This automatic digitization tool was shown to be accurate compared to manual digitization.« less
Time concurrency/phase-time synchronization in digital communications networks
NASA Technical Reports Server (NTRS)
Kihara, Masami; Imaoka, Atsushi
1990-01-01
Digital communications networks have the intrinsic capability of time synchronization which makes it possible for networks to supply time signals to some applications and services. A practical estimation method for the time concurrency on terrestrial networks is presented. By using this method, time concurrency capability of the Nippon Telegraph and Telephone Corporation (NTT) digital communications network is estimated to be better than 300 ns rms at an advanced level, and 20 ns rms at final level.
Sensitivity and specificity of digital retinal imaging for screening diabetic retinopathy.
Lopez-Bastida, J; Cabrera-Lopez, F; Serrano-Aguilar, P
2007-04-01
To assess the effectiveness of a non-mydriatic digital camera (45 degrees -30 degrees photographs) compared with the reference method for screening diabetic retinopathy. Type 1 and 2 diabetic patients (n = 773; 1546 eyes) underwent screening for diabetic retinopathy in a prospective observational study. Hospital-based non-mydriatic digital retinal imaging by a consultant specialist in retinal diseases was compared with slit-lamp biomicroscopy and indirect ophthalmoscopy through dilated pupils, as a gold standard, previously performed in a community health centre by another consultant specialist in retinal diseases. The main outcome measures were sensitivity and specificity of screening methods and prevalence of diabetic retinopathy. The prevalence of any form of diabetic retinopathy was 42.4% (n = 328); the prevalence of sight-threatening including macular oedema and proliferative retinopathy was 9.6% (n = 74). Sensitivity of detection of any diabetic retinopathy by digital imaging was 92% (95% confidence interval 90, 94). Specificity of detection of any diabetic retinopathy was 96% (95, 98). The predictive value of the negative tests was 94% and of a positive test 95%. For sight-threatening retinopathy digital imaging had a sensitivity of 100%. A high sensitivity and specificity are essential for an effective screening programme. These results confirm digital retinal imaging with a non-mydriatic camera as an effective option in community-based screening programmes for diabetic retinopathy.
USDA-ARS?s Scientific Manuscript database
The eButton takes frontal images at 4 second intervals throughout the day. A three-dimensional (3D) manually administered wire mesh procedure has been developed to quantify portion sizes from the two-dimensional (2D) images. This paper reports a test of the interrater reliability and validity of use...
Measurements of Wave Power in Wave Energy Converter Effectiveness Evaluation
NASA Astrophysics Data System (ADS)
Berins, J.; Berins, J.; Kalnacs, A.
2017-08-01
The article is devoted to the technical solution of alternative budget measuring equipment of the water surface gravity wave oscillation and the theoretical justification of the calculated oscillation power. This solution combines technologies such as lasers, WEB-camera image digital processing, interpolation of defined function at irregular intervals, volatility of discrete Fourier transformation for calculating the spectrum.
The persistence of the gravity signal in flax roots
NASA Astrophysics Data System (ADS)
Hasenstein, Karl H.
Although the presentation time of gravitropism has been studied, no data exist as to how long a reorientation stimulus affects the gravitropic response of a root. We tested the duration of gravitropic curvature in roots of Linum usitatissimum after reversing a one hour, 90 degree gravistimulus by increasing time intervals in vertical orientation before clinorotating the roots and acquiring infrared digital images. Clinorotation was performed either parallel or perpendicular to the gravity vector. Under either condition the gravistimulus affected curvature during clinorotation only between two to three minutes. Maximal curvature after one minute of vertical reorientation was 15 degrees within one hour. After three minutes in vertical orientation the observed curvature was not statistically different from vertically growing roots. In both orientations, maximum curvature occurred after 1hr. Perpendicular (horizontal) clinorotation showed decreasing curvature with increasing reorientation time. Parallel (vertical) clinorotation resulted in greater variability to the reorientation time. These data indicate that the gravity stimulus operates essentially memory free and that clinorotation affects the gravity response. Therefore all aspects of clinorotation need to be studied before an assessment of clinostats for the simulation of microgravity is possible and a time limit for memory effects of mechanostimulation can be determined.
All-digital pulse-expansion-based CMOS digital-to-time converter.
Chen, Chun-Chi; Chu, Che-Hsun
2017-02-01
This paper presents a new all-digital CMOS digital-to-time converter (DTC) based on pulse expansion. Pulse expansion is achieved using an all-digital pulse-mixing scheme that can effectively improve the timing resolution and enable the DTC to be concise. Without requiring the Vernier principle or a costly digital-to-analog converter, the DTC comprises a pulse generator for generating a pulse, a pulse-expanding circuit (PEC) for programming timing generation, and a time subtractor for removing the time width of the pulse. The PEC comprises only a delay chain composed of proposed pulse-expanding units and a multiplexer. For accuracy enhancement, a pulse neutralization technique is presented to eliminate undesirable pulse variation. A 4-bit converter was fabricated in a 0.35-μm Taiwan Semiconductor Manufacturing Company CMOS process and had a small area of nearly 0.045 mm 2 . Six chips were tested, all of which exhibited an improved resolution (approximately 16 ps) and low integral nonlinearity (less than ±0.4 least significant bit). The power consumption was 0.2 mW when the sample rate was 1M samples/s and the voltage supply was 3.3 V. The proposed DTC not only has favorable cost and power but also achieves an acceptable resolution without requiring an advanced CMOS process. This study is the first to use pulse expansion in digital-to-time conversion.
All-digital pulse-expansion-based CMOS digital-to-time converter
NASA Astrophysics Data System (ADS)
Chen, Chun-Chi; Chu, Che-Hsun
2017-02-01
This paper presents a new all-digital CMOS digital-to-time converter (DTC) based on pulse expansion. Pulse expansion is achieved using an all-digital pulse-mixing scheme that can effectively improve the timing resolution and enable the DTC to be concise. Without requiring the Vernier principle or a costly digital-to-analog converter, the DTC comprises a pulse generator for generating a pulse, a pulse-expanding circuit (PEC) for programming timing generation, and a time subtractor for removing the time width of the pulse. The PEC comprises only a delay chain composed of proposed pulse-expanding units and a multiplexer. For accuracy enhancement, a pulse neutralization technique is presented to eliminate undesirable pulse variation. A 4-bit converter was fabricated in a 0.35-μ m Taiwan Semiconductor Manufacturing Company CMOS process and had a small area of nearly 0.045 mm2. Six chips were tested, all of which exhibited an improved resolution (approximately 16 ps) and low integral nonlinearity (less than ±0.4 least significant bit). The power consumption was 0.2 mW when the sample rate was 1M samples/s and the voltage supply was 3.3 V. The proposed DTC not only has favorable cost and power but also achieves an acceptable resolution without requiring an advanced CMOS process. This study is the first to use pulse expansion in digital-to-time conversion.
Dawson, David G; Bower, Kristin A; Burnette, Candace N; Holt, Rebecca K; Swearengen, James R; Dabisch, Paul A; Scorpio, Angelo
2017-11-01
We used a continuous-monitoring digital telemetry system to investigate temperature response in New Zealand White rabbits after inhalation or subcutaneous challenge with Bacillus anthracis. Two spore preparations of B. anthracis Ames A2084 were evaluated by using a nose-only inhalation model, and 2 strains, B. anthracis Ames A2084 and B. anthracis UT500, were evaluated in a subcutaneous model. Animal body temperature greater than 3 SD above the mean baseline temperature was considered a significant increase in body temperature (SIBT). All rabbits that exhibited SIBT after challenge by either route of infection or bacterial strain eventually died or were euthanized due to infection, and all rabbits that died or were euthanized due to infection exhibited SIBT during the course of disease. The time at onset of SIBT preceded clinical signs of disease in 94% of the rabbits tested by as long as 2 days. In addition, continuous temperature monitoring facilitated discrimination between the 2 B. anthracis strains with regard to the time interval between SIBT and death. These data suggest that for the New Zealand White rabbit anthrax model, SIBT is a reliable indicator of infection, is predictive of experimental outcome in the absence of treatment, and is measurable prior to the appearance of more severe signs of disease. The use of digital telemetry to monitor infectious disease course in animal models of anthrax can potentially be used in conjunction with other clinical score metrics to refine endpoint euthanasia criteria.
Writing/Thinking in Real Time: Digital Video and Corpus Query Analysis
ERIC Educational Resources Information Center
Park, Kwanghyun; Kinginger, Celeste
2010-01-01
The advance of digital video technology in the past two decades facilitates empirical investigation of learning in real time. The focus of this paper is the combined use of real-time digital video and a networked linguistic corpus for exploring the ways in which these technologies enhance our capability to investigate the cognitive process of…
Akkar, Sinan; Boore, David M.
2009-01-01
Most digital accelerograph recordings are plagued by long-period drifts, best seen in the velocity and displacement time series obtained from integration of the acceleration time series. These drifts often result in velocity values that are nonzero near the end of the record. This is clearly unphysical and can lead to inaccurate estimates of peak ground displacement and long-period spectral response. The source of the long-period noise seems to be variations in the acceleration baseline in many cases. These variations could be due to true ground motion (tilting and rotation, as well as local permanent ground deformation), instrumental effects, or analog-to-digital conversion. Very often the trends in velocity are well approximated by a linear trend after the strong shaking subsides. The linearity of the trend in velocity implies that no variations in the baseline could have occurred after the onset of linearity in the velocity time series. This observation, combined with the lack of any trends in the pre-event motion, allows us to compute the time interval in which any baseline variations could occur. We then use several models of the variations in a Monte Carlo procedure to derive a suite of baseline-corrected accelerations for each noise model using records from the 1999 Chi-Chi earthquake and several earthquakes in Turkey. Comparisons of the mean values of the peak ground displacements, spectral displacements, and residual displacements computed from these corrected accelerations for the different noise models can be used as a guide to the accuracy of the baseline corrections. For many of the records considered here the mean values are similar for each noise model, giving confidence in the estimation of the mean values. The dispersion of the ground-motion measures increases with period and is noise-model dependent. The dispersion of inelastic spectra is greater than the elastic spectra at short periods but approaches that of the elastic spectra at longer periods. The elastic spectra from the most basic processing, in which only the pre-event mean is removed from the acceleration time series, do not diverge from the baseline-corrected spectra until periods of 10-20 sec or more for the records studied here, implying that for many engineering purposes elastic spectra can be used from records with no baseline correction or filtering.
Coherent time-stretch transformation for real-time capture of wideband signals.
Buckley, Brandon W; Madni, Asad M; Jalali, Bahram
2013-09-09
Time stretch transformation of wideband waveforms boosts the performance of analog-to-digital converters and digital signal processors by slowing down analog electrical signals before digitization. The transform is based on dispersive Fourier transformation implemented in the optical domain. A coherent receiver would be ideal for capturing the time-stretched optical signal. Coherent receivers offer improved sensitivity, allow for digital cancellation of dispersion-induced impairments and optical nonlinearities, and enable decoding of phase-modulated optical data formats. Because time-stretch uses a chirped broadband (>1 THz) optical carrier, a new coherent detection technique is required. In this paper, we introduce and demonstrate coherent time stretch transformation; a technique that combines dispersive Fourier transform with optically broadband coherent detection.
A compensation scheme for tape-speed variation in cassette recorders.
Wodicka, G R; Aguirre, A; Burns, S K; Shannon, D C
1988-06-01
A scheme to reduce the data corruption caused by tape-speed variation in cassette recorders used for monitoring infant apnea was developed. Low-frequency timing information is recorded on the tape, under the constraints of the frequency response of the recorder, simultaneously with the other signals. This information is extracted during playback and multiplied to a frequency suitable for data sampling, using an electronic, phase-locked loop. Analog-to-digital conversion of the data is performed at a rate proportional to the tape speed, resulting in compensation for speed variation. No direct modification of the speed-control mechanism of the recorder is required. The scheme was evaluated by comparing interval measurements of recorded timing information with and without compensation. Compensation reduced the error of the measurement by nearly an order of magnitude, which was consistent with theoretical predictions. This allows analysis of clinical value to be performed on signals recorded by systems that lack sophisticated speed-control mechanisms.
Data Processing Aspects of MEDLARS
Austin, Charles J.
1964-01-01
The speed and volume requirements of MEDLARS necessitate the use of high-speed data processing equipment, including paper-tape typewriters, a digital computer, and a special device for producing photo-composed output. Input to the system is of three types: variable source data, including citations from the literature and search requests; changes to such master files as the medical subject headings list and the journal record file; and operating instructions such as computer programs and procedures for machine operators. MEDLARS builds two major stores of data on magnetic tape. The Processed Citation File includes bibliographic citations in expanded form for high-quality printing at periodic intervals. The Compressed Citation File is a coded, time-sequential citation store which is used for high-speed searching against demand request input. Major design considerations include converting variable-length, alphanumeric data to mechanical form quickly and accurately; serial searching by the computer within a reasonable period of time; high-speed printing that must be of graphic quality; and efficient maintenance of various complex computer files. PMID:14119287
DATA PROCESSING ASPECTS OF MEDLARS.
AUSTIN, C J
1964-01-01
The speed and volume requirements of MEDLARS necessitate the use of high-speed data processing equipment, including paper-tape typewriters, a digital computer, and a special device for producing photo-composed output. Input to the system is of three types: variable source data, including citations from the literature and search requests; changes to such master files as the medical subject headings list and the journal record file; and operating instructions such as computer programs and procedures for machine operators. MEDLARS builds two major stores of data on magnetic tape. The Processed Citation File includes bibliographic citations in expanded form for high-quality printing at periodic intervals. The Compressed Citation File is a coded, time-sequential citation store which is used for high-speed searching against demand request input. Major design considerations include converting variable-length, alphanumeric data to mechanical form quickly and accurately; serial searching by the computer within a reasonable period of time; high-speed printing that must be of graphic quality; and efficient maintenance of various complex computer files.
NASA Technical Reports Server (NTRS)
Garvin, James B.; Bufton, Jack L.; Cavanaugh, John F.; Krabill, William B.; Clem, Thomas D.; Frederick, Earl B.; Ward, John L.
1991-01-01
Recently, an airborne lidar system that measures laser pulse time-of-flight and the distortion of the pulse waveform upon reflection from earth surface terrain features was developed and is now operational. This instrument is combined with Global Positioning System (GPS) receivers and a two-axis gyroscope for accurate recovery of aircraft position and pointing attitude. The laser altimeter system is mounted on a high-altitude aircraft platform and operated in a repetitively-pulsed mode for measurements of surface elevation profiles at nadir. The laser transmitter makes use of recently developed short-pulse diode-pumped solid-state laser technology in Q-switched Nd:YAG operating at its fundamental wavelength of 1064 nm. A reflector telescope and silicon avalanche photodiode are the basis of the optical receiver. A high-speed time-interval unit and a separate high-bandwidth waveform digitizer under microcomputer control are used to process the backscattered pulses for measurements of terrain. Other aspects of the lidar system are briefly discussed.
Younes, Magdy; Kuna, Samuel T; Pack, Allan I; Walsh, James K; Kushida, Clete A; Staley, Bethany; Pien, Grace W
2018-02-15
The American Academy of Sleep Medicine has published manuals for scoring polysomnograms that recommend time spent in non-rapid eye movement sleep stages (stage N1, N2, and N3 sleep) be reported. Given the well-established large interrater variability in scoring stage N1 and N3 sleep, we determined the range of time in stage N1 and N3 sleep scored by a large number of technologists when compared to reasonably estimated true values. Polysomnograms of 70 females were scored by 10 highly trained sleep technologists, two each from five different academic sleep laboratories. Range and confidence interval (CI = difference between the 5th and 95th percentiles) of the 10 times spent in stage N1 and N3 sleep assigned in each polysomnogram were determined. Average values of times spent in stage N1 and N3 sleep generated by the 10 technologists in each polysomnogram were considered representative of the true values for the individual polysomnogram. Accuracy of different technologists in estimating delta wave duration was determined by comparing their scores to digitally determined durations. The CI range of the ten N1 scores was 4 to 39 percent of total sleep time (% TST) in different polysomnograms (mean CI ± standard deviation = 11.1 ± 7.1 % TST). Corresponding range for N3 was 1 to 28 % TST (14.4 ± 6.1 % TST). For stage N1 and N3 sleep, very low or very high values were reported for virtually all polysomnograms by different technologists. Technologists varied widely in their assignment of stage N3 sleep, scoring that stage when the digitally determined time of delta waves ranged from 3 to 17 seconds. Manual scoring of non-rapid eye movement sleep stages is highly unreliable among highly trained, experienced technologists. Measures of sleep continuity and depth that are reliable and clinically relevant should be a focus of clinical research. © 2018 American Academy of Sleep Medicine
Seismpol_ a visual-basic computer program for interactive and automatic earthquake waveform analysis
NASA Astrophysics Data System (ADS)
Patanè, Domenico; Ferrari, Ferruccio
1997-11-01
A Microsoft Visual-Basic computer program for waveform analysis of seismic signals is presented. The program combines interactive and automatic processing of digital signals using data recorded by three-component seismic stations. The analysis procedure can be used in either an interactive earthquake analysis or an automatic on-line processing of seismic recordings. The algorithm works in the time domain using the Covariance Matrix Decomposition method (CMD), so that polarization characteristics may be computed continuously in real time and seismic phases can be identified and discriminated. Visual inspection of the particle motion in hortogonal planes of projection (hodograms) reduces the danger of misinterpretation derived from the application of the polarization filter. The choice of time window and frequency intervals improves the quality of the extracted polarization information. In fact, the program uses a band-pass Butterworth filter to process the signals in the frequency domain by analysis of a selected signal window into a series of narrow frequency bands. Significant results supported by well defined polarizations and source azimuth estimates for P and S phases are also obtained for short-period seismic events (local microearthquakes).
Investigating parameters participating in the infant respiratory control system attractor.
Terrill, Philip I; Wilson, Stephen J; Suresh, Sadasivam; Cooper, David M; Dakin, Carolyn
2008-01-01
Theoretically, any participating parameter in a non-linear system represents the dynamics of the whole system. Taken's time delay embedding theory provides the fundamental basis for allowing non-linear analysis to be performed on physiological, time-series data. In practice, only one measurable parameter is required to be measured to convey an accurate representation of the system dynamics. In this paper, the infant respiratory control system is represented using three variables-a digitally sampled respiratory inductive plethysmography waveform, and the derived parameters tidal volume and inter-breath interval time series data. For 14 healthy infants, these data streams were analysed using recurrence plot analysis across one night of sleep. The measured attractor size of these variables followed the same qualitative trends across the nights study. Results suggest that the attractor size measures of the derived IBI and tidal volume are representative surrogates for the raw respiratory waveform. The extent to which the relative attractor sizes of IBI and tidal volume remain constant through changing sleep state could potentially be used to quantify pathology, or maturation of breathing control.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strickland, J. I.
1985-07-02
A radiometer of the switched type has an R.F. switch connecting a detector selectively either to an antenna whose temperature (in terms of noise energy) is to be determined, or to a reference temperature, i.e. a resistive termination. The detector output is passed through an amplifier whose gain is switched between positive and negative values (for example +1 and -1) synchronously with the R.F. switch. The output of the switched gain amplifier is integrated to produce a rising voltage when the gain is positive and a falling one when it is negative. When it is positive the detector is connectedmore » to the antenna. By means of a zero crossing detector, a counter is started when this voltage crosses zero. After a fixed period, the R.F. switch and switched gain amplifier are reversed by the counter to cause the voltage to fall in accordance with the temperature of the resistive termination. The zero crossing detector and a counter measure the time interval until the voltage again crosses zero, such time interval being compared to the fixed period to provide a comparison of the unknown and reference temperatures independent of the gain of the detector, which is a valuable improvement over prior radiometers. Also, by measuring time rather than voltage, the arrangement facilitates providing a digital output more suitable for storage and transmission of the data than the analog output of prior radiometers. The instrument, which is relatively simple, rugged and compact, lends itself well to unattended use in monitoring the effect of rain storms on transmission in the 11.7 to 12.2 GHz band employed for satelite communication.« less
NASA Astrophysics Data System (ADS)
Ritchie, A.; Randle, T. J.; Bountry, J.; Warrick, J. A.
2015-12-01
The stepwise removal of two dams on the Elwha River beginning in September 2011 exposed ~21 million cubic meters of sediment to fluvial erosion and created an unprecedented opportunity to monitor reservoir sediment erosion and river evolution during base level adjustment and a pulsed sediment release. We have conducted more than 60 aerial surveys with a Cessna 172 using a simple custom wing-mount for consumer grade cameras and SfM photogrammetry to produce orthoimagery and digital elevation models in near-real-time at weekly to monthly time intervals. Multiple lidar flights and ground survey campaigns have provided estimates of both systematic and random error for this uniquely dense dataset. Co-registration of multiple surveys during processing reduces systematic error and allows boot-strapping of subsequently established ground control to earlier flights. Measurements chronicle the erosion of 12 million cubic meters of reservoir sediment and record corresponding changes in channel braiding, wood loading and bank erosion. These data capture reservoir and river channel responses to dam removal at resolutions comparable to hydrologic forcing events, allowing us to quantify reservoir sediment budgets on a per-storm basis. This allows for the analysis of sediment transported relative to rates of reservoir drawdown and river stream power for dozens of intervals of time. Temporal decoupling of peak sediment flux and bank erosion rates is noted from these analyses. This dataset illustrates some of the challenges and opportunities emerging with the advent of big data in remote sensing of earth surface processes.
Noar, Seth M; Ribisl, Kurt M; Althouse, Benjamin M; Willoughby, Jessica Fitts; Ayers, John W
2013-12-01
Announcements of cancer diagnoses from public figures may stimulate cancer information seeking and media coverage about cancer. This study used digital surveillance to quantify the effects of pancreatic cancer public figure announcements on online cancer information seeking and cancer media coverage. We compiled a list of public figures (N = 25) who had been diagnosed with or had died from pancreatic cancer between 2006 and 2011. We specified interrupted time series models using data from Google Trends to examine search query shifts for pancreatic cancer and other cancers. Weekly media coverage archived on Google News were also analyzed. Most public figures' pancreatic cancer announcements corresponded with no appreciable change in pancreatic cancer search queries or media coverage. In contrast, Patrick Swayze's diagnosis was associated with a 285% (95% confidence interval [CI]: 212 to 360) increase in pancreatic cancer search queries, though it was only weakly associated with increases in pancreatic cancer media coverage. Steve Jobs's death was associated with a 197% (95% CI: 131 to 266) increase in pancreatic cancer queries and a 3517% (95% CI: 2882 to 4492) increase in pancreatic cancer media coverage. In general, a doubling in pancreatic cancer-specific media coverage corresponded with a 325% increase in pancreatic cancer queries. Digital surveillance is an important tool for future cancer control research and practice. The current application of these methods suggested that pancreatic cancer announcements (diagnosis or death) by particular public figures stimulated media coverage of and online information seeking for pancreatic cancer.
Accuracy of Conventional and Digital Radiography in Detecting External Root Resorption
Mesgarani, Abbas; Haghanifar, Sina; Ehsani, Maryam; Yaghub, Samereh Dokhte; Bijani, Ali
2014-01-01
Introduction: External root resorption (ERR) is associated with physiological and pathological dissolution of mineralized tissues by clastic cells and radiography is one of the most important methods in its diagnosis. The aim of this experimental study was to evaluate the accuracy of conventional intraoral radiography (CR) in comparison with digital radiographic techniques, i.e. charge-coupled device (CCD) and photo-stimulable phosphor (PSP) sensors, in detection of ERR. Methods and Materials: This study was performed on 80 extracted human mandibular premolars. After taking separate initial periapical radiographs with CR technique, CCD and PSP sensors, the artificial defects resembling ERR with variable sizes were created in apical half of the mesial, distal and buccal surfaces of the teeth. Ten teeth were used as control samples without any resorption. The radiographs were then repeated with 2 different exposure times and the images were observed by 3 observers. Data were analyzed using SPSS version 17 and chi-squared and Cohen’s Kappa tests with 95% confidence interval (CI=95%). Result: The CCD had the highest percentage of correct assessment compared to the CR and PSP sensors, although the difference was not significant (P=0.39). It was shown that the higher dosage of radiation increases the accuracy of diagnosis; however, it was only significant for CCD sensor (P=0.02). Also, the accuracy of diagnosis increased with the increase in the size of lesion (P=0.001). Conclusion: Statistically significant difference was not observed for accurate detection of ERR by conventional and digital radiographic techniques. PMID:25386202
Mitsi, Georgia; Mendoza, Enrique Urrea; Wissel, Benjamin D; Barbopoulou, Elena; Dwivedi, Alok K; Tsoulos, Ioannis; Stavrakoudis, Athanassios; Espay, Alberto J; Papapetropoulos, Spyros
2017-01-01
To assess the feasibility, predictive value, and user satisfaction of objectively quantifying motor function in Parkinson's disease (PD) through a tablet-based application (iMotor) using self-administered tests. PD and healthy controls (HCs) performed finger tapping, hand pronation-supination and reaction time tasks using the iMotor application. Thirty-eight participants (19 with PD and 17 HCs) were recruited in the study. PD subjects were 53% male, with a mean age of 67.8 years (±8.8), mean disease duration of 6.5 years (±4.6), Movement Disorders Society version of the Unified Parkinson Disease Rating Scale III score 26.3 (±6.7), and Hoehn & Yahr stage 2. In the univariate analysis, most tapping variables were significantly different in PD compared to HC. Tap interval provided the highest predictive ability (90%). In the multivariable logistic regression model reaction time (reaction time test) ( p = 0.021) and total taps (two-target test) ( p = 0.026) were associated with PD. A combined model with two-target (total taps and accuracy) and reaction time produced maximum discriminatory performance between HC and PD. The overall accuracy of the combined model was 0.98 (95% confidence interval: 0.93-1). iMotor use achieved high rates of patients' satisfaction as evaluated by a patient satisfaction survey. iMotor differentiated PD subjects from HCs using simple alternating tasks of motor function. Results of this feasibility study should be replicated in larger, longitudinal, appropriately designed, controlled studies. The impact on patient care of at-home iMotor-assisted remote monitoring also deserves further evaluation.
Some Protocols For Optical-Fiber Digital Communications
NASA Technical Reports Server (NTRS)
Yeh, Cavour; Gerla, Mario
1989-01-01
One works best in heavy traffic, another, in light traffic. Three protocols proposed for digital communications among stations connected by passive taps to pair of uni-directional optical-fiber buses. Mediate round-robin, bounded-delay access to buses by all stations and particularly suited to fast transmission. Partly because transmission medium passive (no relay stations) and partly because protocols distribute control of network among all stations with provision for addition and deletion of stations (no control stations), communication network able to resist and recover from failures. Implicit token propagates in one direction on one bus and in opposite direction on other bus, minimizing interval of silence between end of one round and beginning of next.
Novel Tool for Complete Digitization of Paper Electrocardiography Data
Harless, Chris; Shah, Amit J.; Wick, Carson A.; Mcclellan, James H.
2013-01-01
Objective: We present a Matlab-based tool to convert electrocardiography (ECG) information from paper charts into digital ECG signals. The tool can be used for long-term retrospective studies of cardiac patients to study the evolving features with prognostic value. Methods and procedures: To perform the conversion, we: 1) detect the graphical grid on ECG charts using grayscale thresholding; 2) digitize the ECG signal based on its contour using a column-wise pixel scan; and 3) use template-based optical character recognition to extract patient demographic information from the paper ECG in order to interface the data with the patients' medical record. To validate the digitization technique: 1) correlation between the digital signals and signals digitized from paper ECG are performed and 2) clinically significant ECG parameters are measured and compared from both the paper-based ECG signals and the digitized ECG. Results: The validation demonstrates a correlation value of 0.85–0.9 between the digital ECG signal and the signal digitized from the paper ECG. There is a high correlation in the clinical parameters between the ECG information from the paper charts and digitized signal, with intra-observer and inter-observer correlations of 0.8–0.9 \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}$({\\rm p}<{0.05})$\\end{document}, and kappa statistics ranging from 0.85 (inter-observer) to 1.00 (intra-observer). Conclusion: The important features of the ECG signal, especially the QRST complex and the associated intervals, are preserved by obtaining the contour from the paper ECG. The differences between the measures of clinically important features extracted from the original signal and the reconstructed signal are insignificant, thus highlighting the accuracy of this technique. Clinical impact: Using this type of ECG digitization tool to carry out retrospective studies on large databases, which rely on paper ECG records, studies of emerging ECG features can be performed. In addition, this tool can be used to potentially integrate digitized ECG information with digital ECG analysis programs and with the patient's electronic medical record. PMID:26594601
Quantification of Wilms' tumor 1 mRNA by digital polymerase chain reaction.
Koizumi, Yuki; Furuya, Daisuke; Endo, Teruo; Asanuma, Kouichi; Yanagihara, Nozomi; Takahashi, Satoshi
2018-02-01
Wilms' tumor 1 (WT1) is overexpressed in various hematopoietic tumors and widely used as a marker of minimal residual disease. WT1 mRNA has been analyzed using quantitative real-time polymerase chain reaction (real-time PCR). In the present study, we analyzed 40 peripheral blood and bone marrow samples obtained from cases of acute myeloid leukemia, acute lymphoblastic leukemia, and myelodysplastic syndrome at Sapporo Medical University Hospital from April 2012 to January 2015. We performed quantification of WT1 was performed using QuantStudio 3D Digital PCR System (Thermo Fisher Scientific) and compared the results between digital PCR and real-time PCR technology. The correlation between digital PCR and real-time PCR was very strong (R = 0.99), and the detection limits of the two methods were equivalent. Digital PCR was able to accurately detect lower WT levels compared with real-time PCR. Digital PCR technology can thus be utilized to predict WT1/ABL1 expression level accurately and should thus be useful for diagnosis or the evaluation of drug efficiency in patients with leukemia.
Army Illumination Model v2 User’s Manual
2011-09-01
Fraction of city luminosity escaping above the horizontal from lamp fixtures 10–15% suggested month4 integer Month of year 2 digits day4 integer Day...of month 2 digits yr4 integer Year 4 digits utc4 real UTC time of observer Equivalent to Zulu or GMT 4 Table 1. AIM input values, their...from 0.10 to 0.15. 2.1.4 Record 4 2.1.4.1 Date and Time The month (1–12), day (1–31), 4- digit year and coordinated universal time (UTC) for the
Experimental simulation and morphological quantification of volcano growth
NASA Astrophysics Data System (ADS)
Grosse, Pablo; Kervyn, Matthieu; Gallland, Olivier; Delcamp, Audray; Poppe, Sam
2016-04-01
Volcanoes display very diverse morphologies as a result of a complex interplay of several constructive and destructive processes. Here the role played by the spatial distribution of eruption centre and by an underlying strike-slip fault in controlling the long term growth of volcanoes is investigated with analogue models. Volcano growth was simulated by depositing loads of granular material (sand-kaolin mixtures) from a point source. An individual load deposited at a fixed location produces a simple symmetrical cone with flank slopes at the angle of repose of the granular material (~33°) that can be considered as the building-block for the experiments. Two sets of experiments were undertaken: (1) the location of deposition of the granular material (i.e. the volcano growth location) was shifted with time following specific probability density functions simulating shifts or migrations in vent location; (2) the location of deposition was kept fixed, but the deposition rate (i.e. the volcano growth rate) was varied coupled with the movement of a basal plate attached to a step-motor simulating a strike-slip displacement under the growing cone (and hence deformation of the cone). During the progression of the experiments, the models were photographed at regular time intervals using four digital cameras positioned at slightly different angles over the models. The photographs were used to generate synthetic digital elevation models (DEMs) with 0.2 mm spatial resolution of each step of the models by applying the MICMAC digital stereo-photogrammetry software. Morphometric data were extracted from the DEMs by applying two IDL-language algorithms: NETVOLC, used to automatically calculate the volcano edifice basal outline, and MORVOLC, used to extract a set of morphometric parameters that characterize the volcano edifice in terms of size, plan shape, profile shape and slopes. Analysis of the DEM-derived morphometric parameters allows to quantitatively characterize the growth evolution of the volcano models in terms of vent distribution and growth rate-deformation rate ratios.
500 MHz Analog-to-Digital Converter Development Program
1972-03-01
marginal level digital input signals. At these encoding speeds, quasi -stable non -digital voltage levels at their outputs still resulted. Further...OF COMMERCE SPRINGFIELD, VA. 22161 Radar Division AEROSPACE GROUP Hughes Aircraft Company * Culver City, California / .A CONTFNTS Page INTRODUCTION...sec. The experimental data also indicated that the short time stability of the timing reference generator caused most of the time jitter associated
AVIRIS onboard data handling and control
NASA Technical Reports Server (NTRS)
Steinkraus, Ronald E.; Hickok, Roger W.
1987-01-01
The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.
New Roles for New Times: Digital Curation for Preservation
ERIC Educational Resources Information Center
Walters, Tyler; Skinner, Katherine
2011-01-01
Digital curation refers to the actions people take to maintain and add value to digital information over its lifecycle, including the processes used when creating digital content. Digital preservation focuses on the "series of managed activities necessary to ensure continued access to digital materials for as long as necessary." In this…
ERIC Educational Resources Information Center
Hurtig, Brent
1998-01-01
Reviews and evaluates Pro Tools 4.1, a multitrack digital audio workstation (DAWs) that imports and synchronizes to QuickTime or AVI digital movies. Audio-for-picture editors lock their digital audio workstations to linear videotape recorders, using complex, expensive time code synchronizers. Highlights Macintosh and Windows based alternatives.…
Petersen, Christian C; Mistlberger, Ralph E
2017-08-01
The mechanisms that enable mammals to time events that recur at 24-h intervals (circadian timing) and at arbitrary intervals in the seconds-to-minutes range (interval timing) are thought to be distinct at the computational and neurobiological levels. Recent evidence that disruption of circadian rhythmicity by constant light (LL) abolishes interval timing in mice challenges this assumption and suggests a critical role for circadian clocks in short interval timing. We sought to confirm and extend this finding by examining interval timing in rats in which circadian rhythmicity was disrupted by long-term exposure to LL or by chronic intake of 25% D 2 O. Adult, male Sprague-Dawley rats were housed in a light-dark (LD) cycle or in LL until free-running circadian rhythmicity was markedly disrupted or abolished. The rats were then trained and tested on 15- and 30-sec peak-interval procedures, with water restriction used to motivate task performance. Interval timing was found to be unimpaired in LL rats, but a weak circadian activity rhythm was apparently rescued by the training procedure, possibly due to binge feeding that occurred during the 15-min water access period that followed training each day. A second group of rats in LL were therefore restricted to 6 daily meals scheduled at 4-h intervals. Despite a complete absence of circadian rhythmicity in this group, interval timing was again unaffected. To eliminate all possible temporal cues, we tested a third group of rats in LL by using a pseudo-randomized schedule. Again, interval timing remained accurate. Finally, rats tested in LD received 25% D 2 O in place of drinking water. This markedly lengthened the circadian period and caused a failure of LD entrainment but did not disrupt interval timing. These results indicate that interval timing in rats is resistant to disruption by manipulations of circadian timekeeping previously shown to impair interval timing in mice.
Advances in Digital Calibration Techniques Enabling Real-Time Beamforming SweepSAR Architectures
NASA Technical Reports Server (NTRS)
Hoffman, James P.; Perkovic, Dragana; Ghaemi, Hirad; Horst, Stephen; Shaffer, Scott; Veilleux, Louise
2013-01-01
Real-time digital beamforming, combined with lightweight, large aperture reflectors, enable SweepSAR architectures, which promise significant increases in instrument capability for solid earth and biomass remote sensing. These new instrument concepts require new methods for calibrating the multiple channels, which are combined on-board, in real-time. The benefit of this effort is that it enables a new class of lightweight radar architecture, Digital Beamforming with SweepSAR, providing significantly larger swath coverage than conventional SAR architectures for reduced mass and cost. This paper will review the on-going development of the digital calibration architecture for digital beamforming radar instrument, such as the proposed Earth Radar Mission's DESDynI (Deformation, Ecosystem Structure, and Dynamics of Ice) instrument. This proposed instrument's baseline design employs SweepSAR digital beamforming and requires digital calibration. We will review the overall concepts and status of the system architecture, algorithm development, and the digital calibration testbed currently being developed. We will present results from a preliminary hardware demonstration. We will also discuss the challenges and opportunities specific to this novel architecture.
Priority queues with bursty arrivals of incoming tasks
NASA Astrophysics Data System (ADS)
Masuda, N.; Kim, J. S.; Kahng, B.
2009-03-01
Recently increased accessibility of large-scale digital records enables one to monitor human activities such as the interevent time distributions between two consecutive visits to a web portal by a single user, two consecutive emails sent out by a user, two consecutive library loans made by a single individual, etc. Interestingly, those distributions exhibit a universal behavior, D(τ)˜τ-δ , where τ is the interevent time, and δ≃1 or 3/2 . The universal behaviors have been modeled via the waiting-time distribution of a task in the queue operating based on priority; the waiting time follows a power-law distribution Pw(τ)˜τ-α with either α=1 or 3/2 depending on the detail of queuing dynamics. In these models, the number of incoming tasks in a unit time interval has been assumed to follow a Poisson-type distribution. For an email system, however, the number of emails delivered to a mail box in a unit time we measured follows a power-law distribution with general exponent γ . For this case, we obtain analytically the exponent α , which is not necessarily 1 or 3/2 and takes nonuniversal values depending on γ . We develop the generating function formalism to obtain the exponent α , which is distinct from the continuous time approximation used in the previous studies.
NASA Astrophysics Data System (ADS)
Villa, Carlos; Kumavor, Patrick; Donkor, Eric
2008-04-01
Photonics Analog-to-Digital Converters (ADCs) utilize a train of optical pulses to sample an electrical input waveform applied to an electrooptic modulator or a reverse biased photodiode. In the former, the resulting train of amplitude-modulated optical pulses is detected (converter to electrical) and quantized using a conversional electronics ADC- as at present there are no practical, cost-effective optical quantizers available with performance that rival electronic quantizers. In the latter, the electrical samples are directly quantized by the electronics ADC. In both cases however, the sampling rate is limited by the speed with which the electronics ADC can quantize the electrical samples. One way to increase the sampling rate by a factor N is by using the time-interleaved technique which consists of a parallel array of N electrical ADC converters, which have the same sampling rate but different sampling phase. Each operating at a quantization rate of fs/N where fs is the aggregated sampling rate. In a system with no real-time operation, the N channels digital outputs are stored in memory, and then aggregated (multiplexed) to obtain the digital representation of the analog input waveform. Alternatively, for real-time operation systems the reduction of storing time in the multiplexing process is desired to improve the time response of the ADC. The complete elimination of memories come expenses of concurrent timing and synchronization in the aggregation of the digital signal that became critical for a good digital representation of the analog signal waveform. In this paper we propose and demonstrate a novel optically synchronized encoder and multiplexer scheme for interleaved photonics ADCs that utilize the N optical signals used to sample different phases of an analog input signal to synchronize the multiplexing of the resulting N digital output channels in a single digital output port. As a proof of concept, four 320 Megasamples/sec 12-bit of resolution digital signals were multiplexed to form an aggregated 1.28 Gigasamples/sec single digital output signal.
NASA Astrophysics Data System (ADS)
Jelinek, Herbert F.; Cree, Michael J.; Leandro, Jorge J. G.; Soares, João V. B.; Cesar, Roberto M.; Luckie, A.
2007-05-01
Proliferative diabetic retinopathy can lead to blindness. However, early recognition allows appropriate, timely intervention. Fluorescein-labeled retinal blood vessels of 27 digital images were automatically segmented using the Gabor wavelet transform and classified using traditional features such as area, perimeter, and an additional five morphological features based on the derivatives-of-Gaussian wavelet-derived data. Discriminant analysis indicated that traditional features do not detect early proliferative retinopathy. The best single feature for discrimination was the wavelet curvature with an area under the curve (AUC) of 0.76. Linear discriminant analysis with a selection of six features achieved an AUC of 0.90 (0.73-0.97, 95% confidence interval). The wavelet method was able to segment retinal blood vessels and classify the images according to the presence or absence of proliferative retinopathy.
Biondich, Paul G.; Overhage, J. Marc; Dexter, Paul R.; Downs, Stephen M.; Lemmon, Larry; McDonald, Clement J.
2002-01-01
Advances in optical character recognition (OCR) software and computer hardware have stimulated a reevaluation of the technology and its ability to capture structured clinical data from preexisting paper forms. In our pilot evaluation, we measured the accuracy and feasibility of capturing vitals data from a pediatric encounter form that has been in use for over twenty years. We found that the software had a digit recognition rate of 92.4% (95% confidence interval: 91.6 to 93.2) overall. More importantly, this system was approximately three times as fast as our existing method of data entry. These preliminary results suggest that with further refinements in the approach and additional development, we may be able to incorporate OCR as another method for capturing structured clinical data. PMID:12463786
Application of image processing technology to problems in manuscript encapsulation. [Codex Hammer
NASA Technical Reports Server (NTRS)
Glackin, D. L.; Korsmo, E. P.
1983-01-01
The long term effects of encapsulation individual sheets of the Codex Hammer were investigated. The manuscript was simulated with similar sheets of paper which were photographed under repeatable raking light conditions to enhance their surface texture, encapsulated in plexiglas, cycled in an environmental test chamber, and rephotographed at selected intervals. The film images were digitized, contrast enhanced, geometrically registered, and apodized. An FFT analysis of a control sheet and two experimental sheets indicates no micro-burnishing, but reveals that the ""mesoscale'' deformations with sizes 8mm are degrading monotonically, which is of no concern. Difference image analysis indicates that the sheets were increasingly stressed with time and that the plexiglas did not provide a sufficient environmental barrier under the simulation conditions. The relationship of these results to the Codex itself is to be determined.
Operational verification of a 40-MHz annular array transducer
Ketterling, Jeffrey A.; Ramachandran, Sarayu; Aristizäbal, Orlando
2006-01-01
An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF) based annular array is presented. The array has a 6 mm total aperture and a 12 mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-μm diameter wires diagonally spaced at 1 mm by 1 mm intervals. The phantom permitted the efficacy of the synthetic focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within ± 2 ns. To further test the system, B-mode images of an excised bovine eye are rendered. PMID:16555771
Data acquisition system for chemical kinetic studies
Zhu, Yu-zhen; Zhou, Xin; Zang, Xiang-sheng
1989-01-01
A microcomputer-interfaced data acquisition system for chemical kinetics (interfacing with laboratory analogue instruments) has been developed. Analogue signals from instruments used in kinetics experiments are amplifed by a wide-range adjustable high-gain operational amplifier and smoothed by an op-based filter, and then digitized at rates of up to 104 samples per channel by an ADC 0816 digitizer. The ADC data transfer and manipulation routine was written in Assembler code and in high-level language; the graphics package and data treatment package is in Basic. For the various sampling speeds, all of the program can be written using Basic-Assembler or completely in Assembler if a high sampling rate is needed. Several numerical treatment methods for chemical kinetics have been utilized to smooth the data from experiments. The computer-interfaced system for second-order chemical kinetic studies was applied to the determination of the rate constant of the saponification of ethyl acetate at 35°C. For this specific problem, an averaging treatment was used which can be called an interval method. The use of this method avoids the diffcully of measuring the starting time of the reaction. Two groups of experimental data and results were used to evaluate the systems performance. All of the results obtained are in agreement with the reference value. PMID:18925219
Adam, Murtaza K; Thornton, Sarah; Regillo, Carl D; Park, Carl; Ho, Allen C; Hsu, Jason
2017-09-01
To determine minimal endoillumination levels required to perform 3-dimensional heads-up vitreoretinal surgery and to correlate endoillumination levels used for measurements of heads-up display (HUD) luminous emittance. Prospective, observational surgical case series of 10 patients undergoing vitreoretinal surgery. Endoillumination levels were set to 40% of maximum output and were decreased at set intervals until the illumination level was 0%. Corresponding luminous emittance (lux) of the HUD was measured 40 cm from the display using a luxmeter (Dr. Meter, Model #LX1010BS). In 9 of 10 cases, the surgeon felt that they could operate comfortably at an endoillumination level of 10% of maximum output with corresponding HUD emittance of 14.3 ± 9.5 lux. In the remaining case, the surgeon felt comfortable at a 3% endoillumination level with corresponding HUD emittance of 15 lux. Below this threshold, subjective image dimness and digital noise limited visibility. Endoillumination levels were correlated with luminous emittance from the 3-dimensional HUD (P < 0.01). The average coefficient of variation of HUD luminance was 0.546. There were no intraoperative complications. With real-time digital processing and automated brightness control, 3-dimensional HUD platforms may allow for reduced intraoperative endoillumination levels and a theoretically reduced risk of retinal phototoxicity during vitreoretinal surgery.
Kakudo, Natsuko; Kushida, Satoshi; Tanaka, Nobuko; Minakata, Tatsuya; Suzuki, Kenji; Kusumoto, Kenji
2011-11-01
Chemical peeling is becoming increasingly popular for skin rejuvenation in dermatological esthetic surgery. Conspicuous facial pores are one of the most frequently encountered skin problems in women of all ages. This study was performed to analyze the effectiveness of reducing conspicuous facial pores using glycolic acid chemical peeling (GACP) based on a novel computer analysis of digital-camera-captured images. GACP was performed a total of five times at 2-week intervals in 22 healthy women. Computerized image analysis of conspicuous, open, and darkened facial pores was performed using the Robo Skin Analyzer CS 50. The number of conspicuous facial pores decreased significantly in 19 (86%) of the 22 subjects, with a mean improvement rate of 34.6%. The number of open pores decreased significantly in 16 (72%) of the subjects, with a mean improvement rate of 11.0%. The number of darkened pores decreased significantly in 18 (81%) of the subjects, with a mean improvement rate of 34.3%. GACP significantly reduces the number of conspicuous facial pores. The Robo Skin Analyzer CS 50 is useful for the quantification and analysis of 'pore enlargement', a subtle finding in dermatological esthetic surgery. © 2011 John Wiley & Sons A/S.
Microcomputer-Based Digital Signal Processing Laboratory Experiments.
ERIC Educational Resources Information Center
Tinari, Jr., Rocco; Rao, S. Sathyanarayan
1985-01-01
Describes a system (Apple II microcomputer interfaced to flexible, custom-designed digital hardware) which can provide: (1) Fast Fourier Transform (FFT) computation on real-time data with a video display of spectrum; (2) frequency synthesis experiments using the inverse FFT; and (3) real-time digital filtering experiments. (JN)
Calderon, Karynna; Forde, Arnell S.; Dadisman, Shawn V.; Wiese, Dana S.; Phelps, Daniel C.
2012-01-01
In September and October of 2003, the U.S. Geological Survey (USGS), in cooperation with the Florida Geological Survey, conducted geophysical surveys of the Atlantic Ocean offshore northeast Florida from St. Augustine, Florida, to the Florida-Georgia border. This report serves as an archive of unprocessed digital boomer subbottom profile data, trackline maps, navigation files, Geographic Information System (GIS) files, Field Activity Collection System (FACS) logs, and formal Federal Geographic Data Committee (FGDC) metadata. Filtered and gained (a relative increase in signal amplitude) digital images of the seismic profiles are also provided. Refer to the Acronyms page for expansions of all acronyms and abbreviations used in this report. The USGS St. Petersburg Coastal and Marine Science Center (SPCMSC) assigns a unique identifier to each cruise or field activity. For example, 03FGS01 tells us the data were collected in 2003 as part of cooperative work with the Florida Geological Survey (FGS) and that the data were collected during the first field activity for that project in that calendar year. Refer to http://walrus.wr.usgs.gov/infobank/programs/html/definition/activity.html for a detailed description of the method used to assign the field activity identification (ID). The naming convention used for each seismic line is as follows: yye##a, where 'yy' are the last two digits of the year in which the data were collected, 'e' is a 1-letter abbreviation for the equipment type (for example, b for boomer), '##' is a 2-digit number representing a specific track, and 'a' is a letter representing the section of a line if recording was prematurely terminated or rerun for quality or acquisition problems. The boomer plate is an acoustic energy source that consists of capacitors charged to a high voltage and discharged through a transducer in the water. The transducer is towed on a sled floating on the water surface and when discharged emits a short acoustic pulse, or shot, which propagates through the water, sediment column, or rock beneath. The acoustic energy is reflected at density boundaries (such as the seafloor, sediment, or rock layers beneath the seafloor), detected by hydrophone receivers, and recorded by a PC-based seismic acquisition system. This process is repeated at timed intervals (for example, 0.5 seconds) and recorded for specific intervals of time (for example, 100 milliseconds). In this way, a two-dimensional (2-D) vertical profile of the shallow geologic structure beneath the ship track is produced. Refer to the handwritten FACS operation log (PDF, 442 KB) for diagrams and descriptions of acquisition geometry, which varied throughout the cruises. Table 1 displays a summary of acquisition parameters. See the digital FACS equipment logs (PDF, 9-13 KB each) for details about the acquisition equipment used. The archived trace data are in standard Society of Exploration Geophysicists (SEG) SEG Y (Barry and others, 1975) format (rev. 0), except for the first 3,200 bytes of the card image header, which are stored in ASCII format instead of the standard EBCDIC format. The SEG Y files may be downloaded and processed with commercial or public domain software such as Seismic Unix (SU) (Cohen and Stockwell, 2005). See the How To Download SEG Y Data page for download instructions. The printable profiles provided here are Graphics Interchange Format (GIF) images that were filtered and gained using SU software. Refer to the Software page for details about the processing and links to example SU processing scripts and USGS software for viewing the SEG Y files (Zihlman, 1992).
Digital carrier demodulator employing components working beyond normal limits
NASA Technical Reports Server (NTRS)
Hurd, William J. (Inventor); Sadr, Ramin (Inventor)
1990-01-01
In a digital device, having an input comprised of a digital sample stream at a frequency F, a method is disclosed for employing a component designed to work at a frequency less than F. The method, in general, is comprised of the following steps: dividing the digital sample stream into odd and even digital samples streams each at a frequency of F/2; passing one of the digital sample streams through the component designed to work at a frequency less than F where the component responds only to the odd or even digital samples in one of the digital sample streams; delaying the other digital sample streams for the time it takes the digital sample stream to pass through the component; and adding the one digital sample stream after passing through the component with the other delayed digital sample streams. In the specific example, the component is a finite impulse response filter of the order ((N + 1)/2) and the delaying step comprised passing the other digital sample streams through a shift register for a time (in sampling periods) of ((N + 1)/2) + r, where r is a pipline delay through the finite impulse response filter.
The Value Versus Volume Yield Problem for Live-Sawn Hardwood Sawlogs
Philip H. Steele; Francis G. Wagner; Lalit Kumar; Philip A. Araman
1993-01-01
The potential conflict between value and volume maximization in sawing hardwood sawlogs by the live sawing method was analyzed. Twenty-four digitally described red oak sawlogs were sawn at the log orientation of highest value yield. Five opening face sawlines were iteratively placed in the sawlog a 1/4-inch intervals and lumber grades, volumes, and values from...
Looking Back and Ahead: 20 Years of Technologies for Language Learning
ERIC Educational Resources Information Center
Godwin-Jones, Robert
2016-01-01
Over the last 20 years Robert Godwin-Jones has written 48 columns on "Emerging Technologies"; an additional six columns have been written by guest columnists. Several topics have been re-examined in regular intervals of approximately five years, namely digital literacy (Vol. 4, Num. 2; Vol. 10, Num. 2; Vol. 14, Num. 3; Vol. 19, Num. 3)…
Bergrath, Sebastian; Rossaint, Rolf; Lenssen, Niklas; Fitzner, Christina; Skorning, Max
2013-01-16
Still picture transmission was performed using a telemedicine system in an Emergency Medical Service (EMS) during a prospective, controlled trial. In this ancillary, retrospective study the quality and content of the transmitted pictures and the possible influences of this application on prehospital time requirements were investigated. A digital camera was used with a telemedicine system enabling encrypted audio and data transmission between an ambulance and a remotely located physician. By default, images were compressed (jpeg, 640 x 480 pixels). On occasion, this compression was deactivated (3648 x 2736 pixels). Two independent investigators assessed all transmitted pictures according to predefined criteria. In cases of different ratings, a third investigator had final decision competence. Patient characteristics and time intervals were extracted from the EMS protocol sheets and dispatch centre reports. Overall 314 pictures (mean 2.77 ± 2.42 pictures/mission) were transmitted during 113 missions (group 1). Pictures were not taken for 151 missions (group 2). Regarding picture quality, the content of 240 (76.4%) pictures was clearly identifiable; 45 (14.3%) pictures were considered "limited quality" and 29 (9.2%) pictures were deemed "not useful" due to not/hardly identifiable content. For pictures with file compression (n = 84 missions) and without (n = 17 missions), the content was clearly identifiable in 74% and 97% of the pictures, respectively (p = 0.003). Medical reports (n = 98, 32.8%), medication lists (n = 49, 16.4%) and 12-lead ECGs (n = 28, 9.4%) were most frequently photographed. The patient characteristics of group 1 vs. 2 were as follows: median age - 72.5 vs. 56.5 years, p = 0.001; frequency of acute coronary syndrome - 24/113 vs. 15/151, p = 0.014. The NACA scores and gender distribution were comparable. Median on-scene times were longer with picture transmission (26 vs. 22 min, p = 0.011), but ambulance arrival to hospital arrival intervals did not differ significantly (35 vs. 33 min, p = 0.054). Picture transmission was used frequently and resulted in an acceptable picture quality, even with compressed files. In most cases, previously existing "paper data" was transmitted electronically. This application may offer an alternative to other modes of ECG transmission. Due to different patient characteristics no conclusions for a prolonged on-scene time can be drawn. Mobile picture transmission holds important opportunities for clinical handover procedures and teleconsultation.
NASA Astrophysics Data System (ADS)
Degaudenzi, Riccardo; Vanghi, Vieri
1994-02-01
In all-digital Trellis-Coded 8PSK (TC-8PSK) demodulator well suited for VLSI implementation, including maximum likelihood estimation decision-directed (MLE-DD) carrier phase and clock timing recovery, is introduced and analyzed. By simply removing the trellis decoder the demodulator can efficiently cope with uncoded 8PSK signals. The proposed MLE-DD synchronization algorithm requires one sample for the phase and two samples per symbol for the timing loop. The joint phase and timing discriminator characteristics are analytically derived and numerical results checked by means of computer simulations. An approximated expression for steady-state carrier phase and clock timing mean square error has been derived and successfully checked with simulation findings. Synchronizer deviation from the Cramer Rao bound is also discussed. Mean acquisition time for the digital synchronizer has also been computed and checked, using the Monte Carlo simulation technique. Finally, TC-8PSK digital demodulator performance in terms of bit error rate and mean time to lose lock, including digital interpolators and synchronization loops, is presented.
Bedrossian, Manuel; Lindensmith, Chris
2017-01-01
Abstract Detection of extant microbial life on Earth and elsewhere in the Solar System requires the ability to identify and enumerate micrometer-scale, essentially featureless cells. On Earth, bacteria are usually enumerated by culture plating or epifluorescence microscopy. Culture plates require long incubation times and can only count culturable strains, and epifluorescence microscopy requires extensive staining and concentration of the sample and instrumentation that is not readily miniaturized for space. Digital holographic microscopy (DHM) represents an alternative technique with no moving parts and higher throughput than traditional microscopy, making it potentially useful in space for detection of extant microorganisms provided that sufficient numbers of cells can be collected. Because sample collection is expected to be the limiting factor for space missions, especially to outer planets, it is important to quantify the limits of detection of any proposed technique for extant life detection. Here we use both laboratory and field samples to measure the limits of detection of an off-axis digital holographic microscope (DHM). A statistical model is used to estimate any instrument's probability of detection at various bacterial concentrations based on the optical performance characteristics of the instrument, as well as estimate the confidence interval of detection. This statistical model agrees well with the limit of detection of 103 cells/mL that was found experimentally with laboratory samples. In environmental samples, active cells were immediately evident at concentrations of 104 cells/mL. Published estimates of cell densities for Enceladus plumes yield up to 104 cells/mL, which are well within the off-axis DHM's limits of detection to confidence intervals greater than or equal to 95%, assuming sufficient sample volumes can be collected. The quantitative phase imaging provided by DHM allowed minerals to be distinguished from cells. Off-axis DHM's ability for rapid low-level bacterial detection and counting shows its viability as a technique for detection of extant microbial life provided that the cells can be captured intact and delivered to the sample chamber in a sufficient volume of liquid for imaging. Key Words: In situ life detection—Extant microorganisms—Holographic microscopy—Ocean Worlds—Enceladus—Imaging. Astrobiology 17, 913–925. PMID:28708412
NASA Astrophysics Data System (ADS)
Rodríguez, Lourdes; Tanarro, Luis M.
2017-04-01
Recent advances in the field of photogrammetry and the computer vision has allowed the improvement of the art 3D Photo-Reconstruction (FR-3D). This technique, which uses Structure from Motion (SfM) and Multi-View Stereo (MVS) reconstruction algorithms, allows us to obtain three-dimensional models of the terrain of high resolution. Its application in the field of Earth Sciences is recent (Westoby et al., 2012, James and Robson, 2012), and has been applied mainly to evaluate the activity of different morphodynamic environments (coastal cliffs, gully erosion, etc.). In this work the FR-3D technique is applied to analyze the geomorphological dynamics of a scarp modelled on the valley-side gully of the right side of the Duraton river (41° 16'N, 3°39'W, 988 m, central Spain). The scarp has a length of about 50 m and a height in the central part of 10 m and the lithology is constituted by red clays with levels of conglomerates of Miocene age. Photographs along the scarp have been taken with a compact digital camera (Canon PowerShot S95, 10 MP) in two different time periods (2014/08/27 and 2016/02/06), and have been processed using Bentley ContextCapture software, generating the respective 3D meshes and from these, directly the Digital Surface Models (DSM) for each date. Finally, DSMs have been compared, obtaining the difference in surface elevations. Previously, at the base of the scarp were placed three wood-stakes, whose coordinates were obtained by GPS, and have been used as control points for georreferencing the models. The DMS obtained have a high resolution (the default cell size of each model are 0.0039 m and 0.0063 m respectively). Volumetric change from elevation differences for the entire time interval (529 days) shows a predominance of sedimentation against erosion (426.79 m3 versus 65.61 m3). In conclusion, FR-3D technique provides high resolution Digital Surface Models, allowing to detect changes in the surface at a high level of detail (cm or even mm). However, the uncertainty due to the difficulty in identifying the control points accurately must be taken into account in the interpretation of the results. This is fundamental for the detection of surface changes at centimetric scale and for a short time interval. James, M.R. y Robson, S. (2012) "Straightforward reconstruction of 3D surfaces and topography with a camera: Accuracy and geoscience application", Journal of Geophysical Research, 117: F03017. Westoby, M.J.; Brasington, J.; Glasser, N.F.; Hambrey, M.J. y Reynolds, J.M. 2012. 'Structure from-Motion' photogrammetry: A low-cost, effective tool for geoscience applications. Geomorphology, 179: 300-314
Mueller, Shane T.; Geerken, Alexander R.; Dixon, Kyle L.; Kroliczak, Gregory; Olsen, Reid H.J.; Miller, Jeremy K.
2015-01-01
Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18–22). Study II evaluated test–retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18–22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen’s d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance. PMID:26713233
Piper, Brian J; Mueller, Shane T; Geerken, Alexander R; Dixon, Kyle L; Kroliczak, Gregory; Olsen, Reid H J; Miller, Jeremy K
2015-01-01
Background. The Psychology Experiment Building Language (PEBL) software consists of over one-hundred computerized tests based on classic and novel cognitive neuropsychology and behavioral neurology measures. Although the PEBL tests are becoming more widely utilized, there is currently very limited information about the psychometric properties of these measures. Methods. Study I examined inter-relationships among nine PEBL tests including indices of motor-function (Pursuit Rotor and Dexterity), attention (Test of Attentional Vigilance and Time-Wall), working memory (Digit Span Forward), and executive-function (PEBL Trail Making Test, Berg/Wisconsin Card Sorting Test, Iowa Gambling Test, and Mental Rotation) in a normative sample (N = 189, ages 18-22). Study II evaluated test-retest reliability with a two-week interest interval between administrations in a separate sample (N = 79, ages 18-22). Results. Moderate intra-test, but low inter-test, correlations were observed and ceiling/floor effects were uncommon. Sex differences were identified on the Pursuit Rotor (Cohen's d = 0.89) and Mental Rotation (d = 0.31) tests. The correlation between the test and retest was high for tests of motor learning (Pursuit Rotor time on target r = .86) and attention (Test of Attentional Vigilance response time r = .79), intermediate for memory (digit span r = .63) but lower for the executive function indices (Wisconsin/Berg Card Sorting Test perseverative errors = .45, Tower of London moves = .15). Significant practice effects were identified on several indices of executive function. Conclusions. These results are broadly supportive of the reliability and validity of individual PEBL tests in this sample. These findings indicate that the freely downloadable, open-source PEBL battery (http://pebl.sourceforge.net) is a versatile research tool to study individual differences in neurocognitive performance.
De Matteis, Sara; Jarvis, Deborah; Young, Heather; Young, Alan; Allen, Naomi; Potts, James; Darnton, Andrew; Rushton, Lesley; Cullinan, Paul
2017-03-01
Objectives The standard approach to the assessment of occupational exposures is through the manual collection and coding of job histories. This method is time-consuming and costly and makes it potentially unfeasible to perform high quality analyses on occupational exposures in large population-based studies. Our aim was to develop a novel, efficient web-based tool to collect and code lifetime job histories in the UK Biobank, a population-based cohort of over 500 000 participants. Methods We developed OSCAR (occupations self-coding automatic recording) based on the hierarchical structure of the UK Standard Occupational Classification (SOC) 2000, which allows individuals to collect and automatically code their lifetime job histories via a simple decision-tree model. Participants were asked to find each of their jobs by selecting appropriate job categories until they identified their job title, which was linked to a hidden 4-digit SOC code. For each occupation a job title in free text was also collected to estimate Cohen's kappa (κ) inter-rater agreement between SOC codes assigned by OSCAR and an expert manual coder. Results OSCAR was administered to 324 653 UK Biobank participants with an existing email address between June and September 2015. Complete 4-digit SOC-coded lifetime job histories were collected for 108 784 participants (response rate: 34%). Agreement between the 4-digit SOC codes assigned by OSCAR and the manual coder for a random sample of 400 job titles was moderately good [κ=0.45, 95% confidence interval (95% CI) 0.42-0.49], and improved when broader job categories were considered (κ=0.64, 95% CI 0.61-0.69 at a 1-digit SOC-code level). Conclusions OSCAR is a novel, efficient, and reasonably reliable web-based tool for collecting and automatically coding lifetime job histories in large population-based studies. Further application in other research projects for external validation purposes is warranted.
Real-time simulation of the TF30-P-3 turbofan engine using a hybrid computer
NASA Technical Reports Server (NTRS)
Szuch, J. R.; Bruton, W. M.
1974-01-01
A real-time, hybrid-computer simulation of the TF30-P-3 turbofan engine was developed. The simulation was primarily analog in nature but used the digital portion of the hybrid computer to perform bivariate function generation associated with the performance of the engine's rotating components. FORTRAN listings and analog patching diagrams are provided. The hybrid simulation was controlled by a digital computer programmed to simulate the engine's standard hydromechanical control. Both steady-state and dynamic data obtained from the digitally controlled engine simulation are presented. Hybrid simulation data are compared with data obtained from a digital simulation provided by the engine manufacturer. The comparisons indicate that the real-time hybrid simulation adequately matches the baseline digital simulation.
Near real-time digital holographic microscope based on GPU parallel computing
NASA Astrophysics Data System (ADS)
Zhu, Gang; Zhao, Zhixiong; Wang, Huarui; Yang, Yan
2018-01-01
A transmission near real-time digital holographic microscope with in-line and off-axis light path is presented, in which the parallel computing technology based on compute unified device architecture (CUDA) and digital holographic microscopy are combined. Compared to other holographic microscopes, which have to implement reconstruction in multiple focal planes and are time-consuming the reconstruction speed of the near real-time digital holographic microscope can be greatly improved with the parallel computing technology based on CUDA, so it is especially suitable for measurements of particle field in micrometer and nanometer scale. Simulations and experiments show that the proposed transmission digital holographic microscope can accurately measure and display the velocity of particle field in micrometer scale, and the average velocity error is lower than 10%.With the graphic processing units(GPU), the computing time of the 100 reconstruction planes(512×512 grids) is lower than 120ms, while it is 4.9s using traditional reconstruction method by CPU. The reconstruction speed has been raised by 40 times. In other words, it can handle holograms at 8.3 frames per second and the near real-time measurement and display of particle velocity field are realized. The real-time three-dimensional reconstruction of particle velocity field is expected to achieve by further optimization of software and hardware. Keywords: digital holographic microscope,
Digitally-bypassed transducers: interfacing digital mockups to real-time medical equipment.
Sirowy, Scott; Givargis, Tony; Vahid, Frank
2009-01-01
Medical device software is sometimes initially developed by using a PC simulation environment that executes models of both the device and a physiological system, and then later by connecting the actual medical device to a physical mockup of the physiological system. An alternative is to connect the medical device to a digital mockup of the physiological system, such that the device believes it is interacting with a physiological system, but in fact all interaction is entirely digital. Developing medical device software by interfacing with a digital mockup enables development without costly or dangerous physical mockups, and enables execution that is faster or slower than real time. We introduce digitally-bypassed transducers, which involve a small amount of hardware and software additions, and which enable interfacing with digital mockups.
Digital Natives and Digital Immigrants: Teaching with Technology
ERIC Educational Resources Information Center
Martin, Ellen Marie Peterson
2011-01-01
Education is witnessing an increasing demand for technology use in the classroom. At the same time, new teachers are entering the profession in high numbers, some being labeled as "Digital Natives" while others are labeled "Digital Immigrants". This qualitative case study investigated the technology practices of Digital Native and Digital…
A 128-channel Time-to-Digital Converter (TDC) inside a Virtex-5 FPGA on the GANDALF module
NASA Astrophysics Data System (ADS)
Büchele, M.; Fischer, H.; Gorzellik, M.; Herrmann, F.; Königsmann, K.; Schill, C.; Schopferer, S.
2012-03-01
The GANDALF 6U-VME64x/VXS module has been developed for the digitization and real time analysis of detector signals. To perform different applications such as analog-to-digital or time-to-digital conversions, coincidence matrix formation, fast pattern recognition and trigger generation, this module comes with exchangeable analog and digital mezzanine cards. Based on this platform, we present a 128-channel TDC which is implemented in a single Xilinx Virtex-5 FPGA using a shifted clock sampling method. In contrast to common TDC concepts, the input signal is sampled by 16 equidistant phase-shifted clocks. A particular challenge of the design is the minimum skew routing of the input signals to the sampling flip-flops. We present measurement results for the differential nonlinearity and the time resolution of the TDC readout system.
Lemaire, Patrick; Brun, Fleur
2014-10-01
Ageing results in the tendency of older adults to repeat the same strategy across consecutive problems more often than young adults, even when such strategy perseveration is not appropriate. Here, we examined how these age-related differences in strategy perseveration are modulated by response-stimulus intervals and problem characteristics. We asked participants to select the best strategy while accomplishing a computational estimation task (i.e., provide approximate sums to two-digit addition problems like 38 + 74). We found that participants repeated the same strategy across consecutive problems more often when the duration between their response and next problem display was short (300 ms) than when it was long (1300 ms). We also found more strategy perseverations in older than in young adults under short Response-Stimulus Intervals, but not under long Response-Stimulus Intervals. Finally, age-related differences in strategy perseveration decreased when problem features helped participants to select the best strategy. These modulations of age-related differences in strategy perseveration by response-stimulus intervals and characteristics of target problems are important for furthering our understanding of mechanisms underlying strategy perseveration and, more generally, ageing effects on strategy selection.
Evaluating the benefits of digital pathology implementation: Time savings in laboratory logistics.
Baidoshvili, Alexi; Bucur, Anca; van Leeuwen, Jasper; van der Laak, Jeroen; Kluin, Philip; van Diest, Paul J
2018-06-20
The benefits of digital pathology for workflow improvement and thereby cost savings in pathology, at least partly outweighing investment costs, are increasingly recognized. Successful implementations in a variety of scenarios start to demonstrate cost benefits of digital pathology for both research and routine diagnostics, contributing to a sound business case encouraging further adoption. To further support new adopters, there is still a need for detailed assessment of the impact this technology has on the relevant pathology workflows with emphasis on time saving. To assess the impact of digital pathology adoption on logistic laboratory tasks (i.e. not including pathologists' time for diagnosis making) in LabPON, a large regional pathology laboratory in The Netherlands. To quantify the benefits of digitization we analyzed the differences between the traditional analog and new digital workflows, carried out detailed measurements of all relevant steps in key analog and digital processes, and compared time spent. We modeled and assessed the logistic savings in five workflows: (1) Routine diagnosis, (2) Multi-disciplinary meeting, (3) External revision requests, (4) Extra stainings and (5) External consultation. On average over 19 working hours were saved on a typical day by working digitally, with the highest savings in routine diagnosis and multi-disciplinary meeting workflows. By working digitally, a significant amount of time could be saved in a large regional pathology lab with a typical case mix. We also present the data in each workflow per task and concrete logistic steps to allow extrapolation to the context and case mix of other laboratories. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Advanced system on a chip microelectronics for spacecraft and science instruments
NASA Astrophysics Data System (ADS)
Paschalidis, Nikolaos P.
2003-01-01
The explosive growth of the modern microelectronics field opens new horizons for the development of new lightweight, low power, and smart spacecraft and science instrumentation systems in the new millennium explorations. Although this growth is mostly driven by the commercial need for low power, portable and computationally intensive products, the applicability is obvious in the space sector. The additional difficulties needed to be overcome for applicability in space include radiation hardness for total ionizing dose and single event effects (SEE), and reliability. Additionally, this new capability introduces a whole new philosophy of design and R&D, with strong implications in organizational and inter-agency program management. One key component specifically developed towards low power, small size, highly autonomous spacecraft systems, is the smart sensor remote input/output (TRIO) chip. TRIO can interface to 32 transducers with current sources/sinks and voltage sensing. It includes front-end analog signal processing, a 10-bit ADC, memory, and standard serial and parallel I/Os. These functions are very useful for spacecraft and subsystems health and status monitoring, and control actions. The key contributions of the TRIO are feasibility of modular architectures, elimination of several miles of wire harnessing, and power savings by orders of magnitude. TRIO freely operates from a single power supply 2.5- 5.5 V with power dissipation <10 mW. This system on a chip device rapidly becomes a NASA and Commercial Space standard as it is already selected by thousands in several new millennium missions, including Europa Orbiter, Mars Surveyor Program, Solar Probe, Pluto Express, Stereo, Contour, Messenger, etc. In the Science Instrumentation field common instruments that can greatly take advantage of the new technologies are: energetic-particle/plasma and wave instruments, imagers, mass spectrometers, X-ray and UV spectrographs, magnetometers, laser rangefinding instruments, etc. Common measurements that apply to many of these instruments are precise time interval measurement and high resolution read-out of solid state detectors. A precise time interval measurement chip was specially developed that achieves ˜100 ps (×10 improvement) time resolution at a power dissipation ˜20 mW (×50 improvement), dead time ˜1.5 μs (×20 improvement), and chip die size 5 mm×5 mm versus two 20 cm×20 cm doubled sided boards. This device is selected as a key enabling technology for several NASA particle, delay line imaging, and laser range finding instruments onboard (NASA Image, Messenger, etc. missions). Another device with universal application is radiation energy read-out from solid state detectors. Multi-channel low-power and end-to-end sensor input—digital output is key for the new generation instruments. The readout channel comprises of a Charge Sensitive Preamplifier with a target sensitivity of ˜1 KeV FWHM at 20 pf detector capacitance, a Shaper Amplifier with programmable time constant/gain, and an ADC. The read-out chip together with the precise time interval chip comprises the essential elements of a common particle spectroscopy instrument. To mention some more applications fast-signal acquisition—and digitization is a very useful function for a category of instrument such as mass spectroscopy and profile laser rangefinding. The single chip approach includes a high bandwidth preamplifier, fast sampling ˜5 ns, analog memory ˜10K locations, 12-bit ADC and serial/parallel I/Os. The wealth of the applications proves the advanced microelectronics field as a key enabling technology for the new millennium space exploration.
NASA Technical Reports Server (NTRS)
Barton, Jonathan S.; Hall, Dorothy K.; Sigurosson, Oddur; Williams, Richard S., Jr.; Smith, Laurence C.; Garvin, James B.
1999-01-01
Two ascending European Space Agency (ESA) Earth Resources Satellites (ERS)-1/-2 tandem-mode, synthetic aperture radar (SAR) pairs are used to calculate the surface elevation of Hofsjokull, an ice cap in central Iceland. The motion component of the interferometric phase is calculated using the 30 arc-second resolution USGS GTOPO30 global digital elevation product and one of the ERS tandem pairs. The topography is then derived by subtracting the motion component from the other tandem pair. In order to assess the accuracy of the resultant digital elevation model (DEM), a geodetic airborne laser-altimetry swath is compared with the elevations derived from the interferometry. The DEM is also compared with elevations derived from a digitized topographic map of the ice cap from the University of Iceland Science Institute. Results show that low temporal correlation is a significant problem for the application of interferometry to small, low-elevation ice caps, even over a one-day repeat interval, and especially at the higher elevations. Results also show that an uncompensated error in the phase, ramping from northwest to southeast, present after tying the DEM to ground-control points, has resulted in a systematic error across the DEM.
Barton, Jonathan S.; Hall, Dorothy K.; Sigurðsson, Oddur; Williams, Richard S.; Smith, Laurence C.; Garvin, James B.; Taylor, Susan; Hardy, Janet
1999-01-01
Two ascending European Space Agency (ESA) Earth Resources Satellites (ERS)-1/-2 tandem-mode, synthetic aperture radar (SAR) pairs are used to calculate the surface elevation of Hofsjokull, an ice cap in central Iceland. The motion component of the interferometric phase is calculated using the 30 arc-second resolution USGS GTOPO30 global digital elevation product and one of the ERS tandem pairs. The topography is then derived by subtracting the motion component from the other tandem pair. In order to assess the accuracy of the resultant digital elevation model (DEM), a geodetic airborne laser-altimetry swath is compared with the elevations derived from the interferometry. The DEM is also compared with elevations derived from a digitized topographic map of the ice cap from the University of Iceland Science Institute. Results show that low temporal correlation is a significant problem for the application of interferometry to small, low-elevation ice caps, even over a one-day repeat interval, and especially at the higher elevations. Results also show that an uncompensated error in the phase, ramping from northwest to southeast, present after tying the DEM to ground-control points, has resulted in a systematic error across the DEM.
Operative record using intraoperative digital data in neurosurgery.
Houkin, K; Kuroda, S; Abe, H
2000-01-01
The purpose of this study was to develop a new method for more efficient and accurate operative records using intra-operative digital data in neurosurgery, including macroscopic procedures and microscopic procedures under an operating microscope. Macroscopic procedures were recorded using a digital camera and microscopic procedures were also recorded using a microdigital camera attached to an operating microscope. Operative records were then recorded digitally and filed in a computer using image retouch software and database base software. The time necessary for editing of the digital data and completing the record was less than 30 minutes. Once these operative records are digitally filed, they are easily transferred and used as database. Using digital operative records along with digital photography, neurosurgeons can document their procedures more accurately and efficiently than by the conventional method (handwriting). A complete digital operative record is not only accurate but also time saving. Construction of a database, data transfer and desktop publishing can be achieved using the intra-operative data, including intra-operative photographs.
NASA Astrophysics Data System (ADS)
Saxena, Shefali; Hawari, Ayman I.
2017-07-01
Digital signal processing techniques have been widely used in radiation spectrometry to provide improved stability and performance with compact physical size over the traditional analog signal processing. In this paper, field-programmable gate array (FPGA)-based adaptive digital pulse shaping techniques are investigated for real-time signal processing. National Instruments (NI) NI 5761 14-bit, 250-MS/s adaptor module is used for digitizing high-purity germanium (HPGe) detector's preamplifier pulses. Digital pulse processing algorithms are implemented on the NI PXIe-7975R reconfigurable FPGA (Kintex-7) using the LabVIEW FPGA module. Based on the time separation between successive input pulses, the adaptive shaping algorithm selects the optimum shaping parameters (rise time and flattop time of trapezoid-shaping filter) for each incoming signal. A digital Sallen-Key low-pass filter is implemented to enhance signal-to-noise ratio and reduce baseline drifting in trapezoid shaping. A recursive trapezoid-shaping filter algorithm is employed for pole-zero compensation of exponentially decayed (with two-decay constants) preamplifier pulses of an HPGe detector. It allows extraction of pulse height information at the beginning of each pulse, thereby reducing the pulse pileup and increasing throughput. The algorithms for RC-CR2 timing filter, baseline restoration, pile-up rejection, and pulse height determination are digitally implemented for radiation spectroscopy. Traditionally, at high-count-rate conditions, a shorter shaping time is preferred to achieve high throughput, which deteriorates energy resolution. In this paper, experimental results are presented for varying count-rate and pulse shaping conditions. Using adaptive shaping, increased throughput is accepted while preserving the energy resolution observed using the longer shaping times.
Tang, L.; Sun, Y.; Buelow, D.; Gu, Z.; Caliendo, A. M.; Pounds, S.
2016-01-01
Given recent advances in the development of quantitative standards, particularly WHO international standards, efforts to better understand the commutability of reference materials have been made. Existing approaches in evaluating commutability include prediction intervals and correspondence analysis; however, the results obtained from existing approaches may be ambiguous. We have developed a “deviation-from-ideal” (DFI) approach to evaluate commutability of standards and applied it to the assessment of Epstein-Bar virus (EBV) load testing in four quantitative PCR assays, treating digital PCR as a reference assay. We then discuss advantages and limitations of the DFI approach as well as experimental design to best evaluate the commutability of an assay in practice. PMID:27076654
Discrete-time stability of continuous-time controller designs for large space structures
NASA Technical Reports Server (NTRS)
Balas, M. J.
1982-01-01
In most of the stable control designs for flexible structures, continuous time is assumed. However, in view of the implementation of the controllers by on-line digital computers, the discrete-time stability of such controllers is an important consideration. In the case of direct-velocity feedback (DVFB), involving negative feedback from collocated force actuators and velocity sensors, it is not immediately apparent how much delay due to digital implementation of DVFB can be tolerated without loss of stability. The present investigation is concerned with such questions. A study is conducted of the discrete-time stability of DVFB, taking into account an employment of Euler's method of approximation of the time derivative. The obtained result gives an indication of the acceptable time-step size for stable digital implementation of DVFB. A result derived in connection with the consideration of the discrete-time stability of stable continuous-time systems provides a general condition under which digital implementation of such a system will remain stable.
Design and performance of a custom ASIC digitizer for wire chamber readout in 65 nm CMOS technology
NASA Astrophysics Data System (ADS)
Lee, M. J.; Brown, D. N.; Chang, J. K.; Ding, D.; Gnani, D.; Grace, C. R.; Jones, J. A.; Kolomensky, Y. G.; von der Lippe, H.; Mcvittie, P. J.; Stettler, M. W.; Walder, J.-P.
2015-06-01
We present the design and performance of a prototype ASIC digitizer for integrated wire chamber readout, implemented in 65 nm commercial CMOS technology. Each channel of the 4-channel prototype is composed of two 16-bit Time-to-Digital Converters (TDCs), one 8-bit Analog-to-Digital Converter (ADC), a front-end preamplifier and shaper, plus digital and analog buffers that support a variety of digitization chains. The prototype has a multiplexed digital backend that executes a state machine, distributes control and timing signals, and buffers data for serial output. Laboratory bench tests measure the absolute TDC resolution between 74 ps and 480 ps, growing with the absolute delay, and a relative time resolution of 19 ps. Resolution outliers due to cross-talk between clock signals and supply or reference voltages are seen. After calibration, the ADC displays good linearity and noise performance, with an effective number of bits of 6.9. Under normal operating conditions the circuit consumes 32 mW per channel. Potential design improvements to address the resolution drift and tails are discussed.
Timescale- and Sensory Modality-Dependency of the Central Tendency of Time Perception.
Murai, Yuki; Yotsumoto, Yuko
2016-01-01
When individuals are asked to reproduce intervals of stimuli that are intermixedly presented at various times, longer intervals are often underestimated and shorter intervals overestimated. This phenomenon may be attributed to the central tendency of time perception, and suggests that our brain optimally encodes a stimulus interval based on current stimulus input and prior knowledge of the distribution of stimulus intervals. Two distinct systems are thought to be recruited in the perception of sub- and supra-second intervals. Sub-second timing is subject to local sensory processing, whereas supra-second timing depends on more centralized mechanisms. To clarify the factors that influence time perception, the present study investigated how both sensory modality and timescale affect the central tendency. In Experiment 1, participants were asked to reproduce sub- or supra-second intervals, defined by visual or auditory stimuli. In the sub-second range, the magnitude of the central tendency was significantly larger for visual intervals compared to auditory intervals, while visual and auditory intervals exhibited a correlated and comparable central tendency in the supra-second range. In Experiment 2, the ability to discriminate sub-second intervals in the reproduction task was controlled across modalities by using an interval discrimination task. Even when the ability to discriminate intervals was controlled, visual intervals exhibited a larger central tendency than auditory intervals in the sub-second range. In addition, the magnitude of the central tendency for visual and auditory sub-second intervals was significantly correlated. These results suggest that a common modality-independent mechanism is responsible for the supra-second central tendency, and that both the modality-dependent and modality-independent components of the timing system contribute to the central tendency in the sub-second range.
Caumo, Francesca; Zorzi, Manuel; Brunelli, Silvia; Romanucci, Giovanna; Rella, Rossella; Cugola, Loredana; Bricolo, Paola; Fedato, Chiara; Montemezzi, Stefania; Houssami, Nehmat
2018-04-01
Purpose To examine the outcomes of a breast cancer screening program based on digital breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography compared with those after full-field digital mammography (FFDM). Materials and Methods This prospective study included 16 666 asymptomatic women aged 50-69 years who were recruited in April 2015 through March 2016 for DBT plus synthetic 2D screening in the Verona screening program. A comparison cohort of women screened with FFDM (n = 14 423) in the previous year was included. Screening detection measures for the two groups were compared by calculating the proportions associated with each outcome, and the relative rates (RRs) were estimated with multivariate logistic regression. Results Cancer detection rate (CDR) for DBT plus synthetic 2D imaging was 9.30 per 1000 screening examinations versus 5.41 per 1000 screening examinations with FFDM (RR, 1.72; 95% confidence interval [CI]: 1.30, 2.29). CDR was significantly higher in patients screened with DBT plus synthetic 2D imaging than in those screened with FFDM among women classified as having low breast density (RR, 1.53; 95% CI: 1.13, 2.10) or high breast density (RR, 2.86; 95% CI: 1.42, 6.25). The positive predictive value (PPV) for recall was almost doubled with DBT plus synthetic 2D imaging: 23.3% versus 12.9% of recalled patients who were screened with FFDM (RR, 1.81; 95% CI: 1.34, 2.47). The recall rate was similar between groups (RR, 0.95; 95% CI: 0.84, 1.06), whereas the recall rate with invasive assessment was higher for DBT plus synthetic 2D imaging than for FFDM (RR, 1.93; 95% CI: 1.31, 2.03). The mean number of screening studies interpreted per hour was significantly lower for screening examinations performed with DBT plus synthetic 2D imaging (38.5 screens per hour) than with FFDM (60 screens per hour) (P < .001). Conclusion DBT plus synthetic 2D imaging increases CDRs with recall rates comparable to those of FFDM. DBT plus synthetic 2D imaging increased image reading time and the time needed for invasive assessments. © RSNA, 2017.
Woods, Susan S; Forsberg, Christopher W; Schwartz, Erin C; Nazi, Kim M; Hibbard, Judith H; Houston, Thomas K; Gerrity, Martha
2017-10-17
As electronic health records and computerized workflows expand, there are unprecedented opportunities to digitally connect with patients using secure portals. To realize the value of patient portals, initial reach across populations will need to be demonstrated, as well as sustained usage over time. The study aim was to identify patient factors associated with short-term and long-term portal usage after patients registered to access all portal functions. We prospectively followed a cohort of patients at a large Department of Veterans Affairs (VA) health care facility who recently completed identity proofing to use the VA patient portal. Information collected at baseline encompassed patient factors potentially associated with portal usage, including: demographics, Internet access and use, health literacy, patient activation, and self-reported health conditions. The primary outcome was the frequency of portal log-ins during 6-month and 18-month time intervals after study enrollment. A total of 270 study participants were followed prospectively. Almost all participants (260/268, 97.0%) reported going online, typically at home (248/268, 92.5%). At 6 months, 84.1% (227/270) of participants had visited the portal, with some variation in usage across demographic and health-related subgroups. There were no significant differences in portal log-ins by age, gender, education, marital status, race/ethnicity, distance to a VA facility, or patient activation measure. Significantly higher portal usage was seen among participants using high-speed broadband at home, greater self-reported ability using the Internet, and routinely going online. By 18 months, 91% participants had logged in to the portal, and no significant associations were found between usage and demographics, health status, or patient activation. When examining portal activity between 6 and 18 months, patients who were infrequent or high portal users remained in those categories, respectively. Short-term and long-term portal usage was associated with having broadband at home, high self-rated ability when using the Internet, and overall online behavior. Digital inclusion, or ready access to the Internet and digital skills, appears to be a social determinant in patient exposure to portal services. ©Susan S Woods, Christopher W Forsberg, Erin C Schwartz, Kim M Nazi, Judith H Hibbard, Thomas K Houston, Martha Gerrity. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 17.10.2017.
ERIC Educational Resources Information Center
Cash, Carla Davis
2009-01-01
Thirty-six nonmusicians practiced a five-element key-press sequence on a digital piano, repeating the sequence as quickly and accurately as possible during twelve 30-s practice blocks alternating with 30-s pauses. Twelve learners rested for 5 min between Blocks 3 and 4, another 12 learners rested for 5 min between Blocks 9 and 10, and the…
NASA Astrophysics Data System (ADS)
Pechousek, J.; Prochazka, R.; Cuda, J.; Frydrych, J.; Jancik, D.
2010-07-01
This paper is focused on a quality characterizing the Mössbauer spectra measured for various frequencies of the velocity signal. Standard electromechanical double-loudspeaker drive and digital PID velocity controller were used for calibration spectra measurement in the frequency interval from 4 up to 100 Hz. Several parameters were evaluated for recommendation of the suitable velocity signal frequency.
Elizabeth T. Keppeler; Robert R. Ziemer; Peter H. Cafferata
1994-01-01
Abstract - In 1987, a 0.83-ha zero-order swale was instrumented with 58 pierometers and 25 tensiometers along several hillslope transects. Through 1993, soil moisture conditions were measured by pressure transducers connected to a digital data logger recording at 15-minute intervals. In August 1989, the 100-year-old second-growth forest in the swale was felled. Logs...
Morley, Alexander A
2014-09-01
Digital PCR for quantification of a target of interest has been independently developed several times, being described in 1990 and 1991 using the term "limiting dilution PCR" and in 1999 using the term "digital PCR". It came into use in the decade following its first development but its use was cut short by the description of real-time PCR in 1996. However digital PCR has now had a renaissance due to the recent development of new instruments and chemistry which have made it a much simpler and more practical technique.
Time Management in the Digital Era
ERIC Educational Resources Information Center
Wodarz, Nan
2013-01-01
School business officials can strike a balance between setting a long-term strategy and responding to short-term situations by implementing time management strategies. This article presents tips for time management that could help boost productivity and save time in this digital era. Tips include decreasing meeting times via Skype or…
Kerlikowske, Karla; Scott, Christopher G; Mahmoudzadeh, Amir P; Ma, Lin; Winham, Stacey; Jensen, Matthew R; Wu, Fang Fang; Malkov, Serghei; Pankratz, V Shane; Cummings, Steven R; Shepherd, John A; Brandt, Kathleen R; Miglioretti, Diana L; Vachon, Celine M
2018-06-05
In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Case-control. San Francisco Mammography Registry and Mayo Clinic. 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density. National Cancer Institute.
Oporto V, Gonzalo H; Fuentes, Ramón; Borie, Eduardo; del Sol, Mariano; Orsi, Iara Augusta; Engelke, Wilfried
2014-01-01
Regeneration of resorbed edentulous sites can be induced by bone grafts from the subject himself and/or by the use of biomaterials. At present, there has been an extensive search for biomaterials that are evaluated by artificially creating one or more critical defects. The aim of this work was to clinically and radiographically analyze bone formation by the use of some biomaterials in artificially created defects in the parietal bone of rabbits. Six rabbits were used, creating defects of 8 mm in diameter in parietal bones. One defect was maintained with coagulum only, and in others, freeze-dried bone allograft (FDBA), autologous bone, and a combination of autologous bone with FDBA respectively, were added. Animals were sacrificed at 15-90 days with 2 weeks interval each, and calvaria were analyzed macroscopically, measuring by digital caliper the lack of filling at the surface of defects, identifying limits at anteroposterior and coronal view, realizing a digital photograph register of their external surfaces. This was subsequently evaluated radiographically by occlusal film radiography used to quantify its density through software. In conclusion, autologous bone showed the best behavior, clinically as well as radiographically. However, FDBA is a good option as an alternative to autologous bone as its behavior was slightly lower over time. The combination of autologous bone and FDBA in the same defect showed results considerably inferior to grafts used separately. Low radiopacity and clear limits were observed through time for the control coagulum filled defect. PMID:25126163
He, Yugui; Feng, Jiwen; Zhang, Zhi; Wang, Chao; Wang, Dong; Chen, Fang; Liu, Maili; Liu, Chaoyang
2015-08-01
High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with high data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately -170 for (1)H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo (1)H MRI at 0.35 T.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Yugui; Liu, Chaoyang, E-mail: chyliu@wipm.ac.cn; State Key Laboratory of Magnet Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071
2015-08-15
High sensitivity, high data rates, fast pulses, and accurate synchronization all represent challenges for modern nuclear magnetic resonance spectrometers, which make any expansion or adaptation of these devices to new techniques and experiments difficult. Here, we present a Peripheral Component Interconnect Express (PCIe)-based highly integrated distributed digital architecture pulsed spectrometer that is implemented with electron and nucleus double resonances and is scalable specifically for broad dynamic nuclear polarization (DNP) enhancement applications, including DNP-magnetic resonance spectroscopy/imaging (DNP-MRS/MRI). The distributed modularized architecture can implement more transceiver channels flexibly to meet a variety of MRS/MRI instrumentation needs. The proposed PCIe bus with highmore » data rates can significantly improve data transmission efficiency and communication reliability and allow precise control of pulse sequences. An external high speed double data rate memory chip is used to store acquired data and pulse sequence elements, which greatly accelerates the execution of the pulse sequence, reduces the TR (time of repetition) interval, and improves the accuracy of TR in imaging sequences. Using clock phase-shift technology, we can produce digital pulses accurately with high timing resolution of 1 ns and narrow widths of 4 ns to control the microwave pulses required by pulsed DNP and ensure overall system synchronization. The proposed spectrometer is proved to be both feasible and reliable by observation of a maximum signal enhancement factor of approximately −170 for {sup 1}H, and a high quality water image was successfully obtained by DNP-enhanced spin-echo {sup 1}H MRI at 0.35 T.« less
NASA Astrophysics Data System (ADS)
Theissen, K. M.; Dunbar, R. B.
2005-12-01
In tropical regions, there are few paleoclimate archives with the necessary resolution to investigate climate variability at interannual-to-decadal timescales prior to the onset of the instrumental record. Interannual variability associated with the El Niño Southern Oscillation (ENSO) is well documented in the instrumental record and the importance of the precessional forcing of millennial variability has been established in studies of tropical paleoclimate records. In contrast, decade-to-century variability is still poorly understood. Here, we examine interannual to decadal variability in the northern Altiplano of South America using digital image analysis of a floating interval of varved sediments of middle Holocene age (~6160-6310 yr BP) from Lake Titicaca. Multi-taper method (MTM) and wavelet frequency-domain analyses were performed on a time series generated from a gray-scaled digital image of the mm-thick laminations. Our results indicate significant power at a decadal periodicity (10-12 years) associated with the Schwabe cycle of solar activity. Frequency-domain analysis also indicates power at 2-2.5 year periodicities associated with ENSO. Similarly, spectral analysis of a 75 year instrumental record of Titicaca lake level shows significant power at both solar and ENSO periodicities. Although both of the examined records are short, our results imply that during both the mid-Holocene and modern times, solar and ENSO variability may have contributed to high frequency climate fluctuations over the northern Altiplano. We suspect that solar influence on large-scale atmospheric circulation features may account for the decadal variability in the mid-Holocene and present-day water balance of the Altiplano.
Taking Digital Creativity to the Art Classroom: Mystery Box Swap
ERIC Educational Resources Information Center
Shin, Ryan
2010-01-01
Today's students are the first generation to grow up with computers, cell-phones, video games, music and video players, and other digital technologies. As "digital natives", a new term coined by Prensky (2001), they spend more time reading text messaging lines than lines from books, and they spend more time on Facebook than putting their energies…
Young Children and Screen Time: Creating a Mindful Approach to Digital Technology
ERIC Educational Resources Information Center
Neumann, Michelle Margaret
2015-01-01
To effectively address early childhood screen time concerns raised by parents and policy makers it is important to examine the current home digital environments of young children. The present study draws upon research that examined the home digital environment of Australian parents and their children (aged 2 to 4; N = 69). Parents completed a…
Short-interval SMS wind vector determinations for a severe local storms area
NASA Technical Reports Server (NTRS)
Peslen, C. A.
1980-01-01
Short-interval SMS-2 visible digital image data are used to derive wind vectors from cloud tracking on time-lapsed sequences of geosynchronous satellite images. The cloud tracking areas are located in the Central Plains, where on May 6, 1975 hail-producing thunderstorms occurred ahead of a well defined dry line. Cloud tracking is performed on the Goddard Space Flight Center Atmospheric and Oceanographic Information Processing System. Lower tropospheric cumulus tracers are selected with the assistance of a cloud-top height algorithm. Divergence is derived from the cloud motions using a modified Cressman (1959) objective analysis technique which is designed to organize irregularly spaced wind vectors into uniformly gridded wind fields. The results demonstrate the feasibility of using satellite-derived wind vectors and their associated divergence fields in describing the conditions preceding severe local storm development. For this case, an area of convergence appeared ahead of the dry line and coincided with the developing area of severe weather. The magnitude of the maximum convergence varied between -10 to the -5th and -10 to the -14th per sec. The number of satellite-derived wind vectors which were required to describe conditions of the low-level atmosphere was adequate before numerous cumulonimbus cells formed. This technique is limited in areas of advanced convection.
Measuring the EMS patient access time interval and the impact of responding to high-rise buildings.
Morrison, Laurie J; Angelini, Mark P; Vermeulen, Marian J; Schwartz, Brian
2005-01-01
To measure the patient access time interval and characterize its contribution to the total emergency medical services (EMS) response time interval; to compare the patient access time intervals for patients located three or more floors above ground with those less than three floors above or below ground, and specifically in the apartment subgroup; and to identify barriers that significantly impede EMS access to patients in high-rise apartments. An observational study of all patients treated by an emergency medical technician paramedics (EMT-P) crew was conducted using a trained independent observer to collect time intervals and identify potential barriers to access. Of 118 observed calls, 25 (21%) originated from patients three or more floors above ground. The overall median and 90th percentile (95% confidence interval) patient access time intervals were 1.61 (1.27, 1.91) and 3.47 (3.08, 4.05) minutes, respectively. The median interval was 2.73 (2.22, 3.03) minutes among calls from patients located three or more stories above ground compared with 1.25 (1.07, 1.55) minutes among those at lower levels. The patient access time interval represented 23.5% of the total EMS response time interval among calls originating less than three floors above or below ground and 32.2% of those located three or more stories above ground. The most frequently encountered barriers to access included security code entry requirements, lack of directional signs, and inability to fit the stretcher into the elevator. The patient access time interval is significantly long and represents a substantial component of the total EMS response time interval, especially among ambulance calls originating three or more floors above ground. A number of barriers appear to contribute to delayed paramedic access.
Modulation of human time processing by subthalamic deep brain stimulation.
Wojtecki, Lars; Elben, Saskia; Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons
2011-01-01
Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥ 130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥ 130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds.
Modulation of Human Time Processing by Subthalamic Deep Brain Stimulation
Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons
2011-01-01
Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds. PMID:21931767
van Ravesteyn, Nicolien T; van Lier, Lisanne; Schechter, Clyde B; Ekwueme, Donatus U; Royalty, Janet; Miller, Jacqueline W; Near, Aimee M; Cronin, Kathleen A; Heijnsdijk, Eveline A M; Mandelblatt, Jeanne S; de Koning, Harry J
2015-05-01
The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40-64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]); costs (for screening and diagnostics); and number of women reached. NBCCEDP 2010 data and data representative of the program's target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. The models predicted 8.0-8.3 LYG per 1,000 film screens for black women, 5.9-7.5 for white women, and 4.0-4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%-4%), but had higher costs (34%-35%). Assuming a fixed budget, 25%-26% fewer women could be served, resulting in 22%-24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%-13% increase by only including biennial screening. Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. Copyright © 2015 American Journal of Preventive Medicine. All rights reserved.
Transition From Film to Digital Mammography
van Ravesteyn, Nicolien T.; van Lier, Lisanne; Schechter, Clyde B.; Ekwueme, Donatus U.; Royalty, Janet; Miller, Jacqueline W.; Near, Aimee M.; Cronin, Kathleen A.; Heijnsdijk, Eveline A.M.; Mandelblatt, Jeanne S.; de Koning, Harry J.
2015-01-01
Introduction The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides mammograms and diagnostic services for low-income, uninsured women aged 40–64 years. Mammography facilities within the NBCCEDP gradually shifted from plain-film to digital mammography. The purpose of this study is to assess the impact of replacing film with digital mammography on health effects (deaths averted, life-years gained [LYG]), costs (for screening and diagnostics), and number of women reached. Methods NBCCEDP 2010 data and data representative of the program’s target population were used in two established microsimulation models. Models simulated observed screening behavior including different screening intervals (annual, biennial, irregular) and starting ages (40, 50 years) for white, black, and Hispanic women. Model runs were performed in 2012. Results The models predicted 8.0–8.3 LYG per 1,000 film screens for black women, 5.9–7.5 for white women, and 4.0–4.5 for Hispanic women. For all race/ethnicity groups, digital mammography had more LYG than film mammography (2%–4%), but had higher costs (34%–35%). Assuming a fixed budget, 25%–26% fewer women could be served, resulting in 22%–24% fewer LYG if all mammograms were converted to digital. The loss in LYG could be reversed to an 8%–13% increase by only including biennial screening. Conclusions Digital could result in slightly more LYG than film mammography. However, with a fixed budget, fewer women may be served with fewer LYG. Changes in the program, such as only including biennial screening, will increase LYG/screen and could offset the potential decrease in LYG when shifting to digital mammography. PMID:25891052
Agreement and reading time for differently-priced devices for the digital capture of X-ray films.
Salazar, Antonio José; Camacho, Juan Camilo; Aguirre, Diego Andrés
2012-03-01
We assessed the reliability of three digital capture devices: a film digitizer (which cost US $15,000), a flat-bed scanner (US $1800) and a digital camera (US $450). Reliability was measured as the agreement between six observers when reading images acquired from a single device and also in terms of the pair-device agreement. The images were 136 chest X-ray cases. The variables measured were the interstitial opacities distribution, interstitial patterns, nodule size and percentage pneumothorax size. The agreement between the six readers when reading images acquired from a single device was similar for the three devices. The pair-device agreements were moderate for all variables. There were significant differences in reading-time between devices: the mean reading-time for the film digitizer was 93 s, it was 59 s for the flat-bed scanner and 70 s for the digital camera. Despite the differences in their cost, there were no substantial differences in the performance of the three devices.
A simple autocorrelation algorithm for determining grain size from digital images of sediment
Rubin, D.M.
2004-01-01
Autocorrelation between pixels in digital images of sediment can be used to measure average grain size of sediment on the bed, grain-size distribution of bed sediment, and vertical profiles in grain size in a cross-sectional image through a bed. The technique is less sensitive than traditional laboratory analyses to tails of a grain-size distribution, but it offers substantial other advantages: it is 100 times as fast; it is ideal for sampling surficial sediment (the part that interacts with a flow); it can determine vertical profiles in grain size on a scale finer than can be sampled physically; and it can be used in the field to provide almost real-time grain-size analysis. The technique can be applied to digital images obtained using any source with sufficient resolution, including digital cameras, digital video, or underwater digital microscopes (for real-time grain-size mapping of the bed). ?? 2004, SEPM (Society for Sedimentary Geology).
Warburton, William K.; Zhou, Zhiquing
1999-01-01
A high speed, digitally based, signal processing system which accepts a digitized input signal and detects the presence of step-like pulses in the this data stream, extracts filtered estimates of their amplitudes, inspects for pulse pileup, and records input pulse rates and system livetime. The system has two parallel processing channels: a slow channel, which filters the data stream with a long time constant trapezoidal filter for good energy resolution; and a fast channel which filters the data stream with a short time constant trapezoidal filter, detects pulses, inspects for pileups, and captures peak values from the slow channel for good events. The presence of a simple digital interface allows the system to be easily integrated with a digital processor to produce accurate spectra at high count rates and allow all spectrometer functions to be fully automated. Because the method is digitally based, it allows pulses to be binned based on time related values, as well as on their amplitudes, if desired.
Discrete-time modelling of musical instruments
NASA Astrophysics Data System (ADS)
Välimäki, Vesa; Pakarinen, Jyri; Erkut, Cumhur; Karjalainen, Matti
2006-01-01
This article describes physical modelling techniques that can be used for simulating musical instruments. The methods are closely related to digital signal processing. They discretize the system with respect to time, because the aim is to run the simulation using a computer. The physics-based modelling methods can be classified as mass-spring, modal, wave digital, finite difference, digital waveguide and source-filter models. We present the basic theory and a discussion on possible extensions for each modelling technique. For some methods, a simple model example is chosen from the existing literature demonstrating a typical use of the method. For instance, in the case of the digital waveguide modelling technique a vibrating string model is discussed, and in the case of the wave digital filter technique we present a classical piano hammer model. We tackle some nonlinear and time-varying models and include new results on the digital waveguide modelling of a nonlinear string. Current trends and future directions in physical modelling of musical instruments are discussed.
Memory skills mediating superior memory in a world-class memorist.
Ericsson, K Anders; Cheng, Xiaojun; Pan, Yafeng; Ku, Yixuan; Ge, Yi; Hu, Yi
2017-10-01
Laboratory studies have investigated how individuals with normal memory spans attained digit spans over 80 digits after hundreds of hours of practice. Experimental analyses of their memory skills suggested that their attained memory spans were constrained by the encoding time, for the time needed will increase if the length of digit sequences to be memorised becomes longer. These constraints seemed to be violated by a world-class memorist, Feng Wang (FW), who won the World Memory Championship by recalling 300 digits presented at 1 digit/s. In several studies we examined FW's memory skills underlying his exceptional performance. First FW reproduced his superior memory span of 200 digits under laboratory condition, and we obtained his retrospective reports describing his encoding/retrieval processes (Experiment 1). Further experiments used self-paced memorisation to identify temporal characteristics of encoding of digits in 4-digit clusters (Experiment 2), and explored memory encoding at presentation speeds much faster than 1 digit/s (Experiment 3). FW's superiority over previous digit span experts is explained by his acquisition of well-known mnemonic techniques and his training that focused on rapid memorisation. His memory performance supports the feasibility of acquiring memory skills for improved working memory based on storage in long-term memory.
Schumacher, J; DeGraves, F; Cesar, F; Duran, S
2014-09-01
A local anaesthetic agent capable of temporarily resolving lameness after being administered perineurally would be helpful because rapid return of lameness would allow for other analgesic techniques to be performed within a short period of time. To determine if a 3% solution of ketamine hydrochloride (HCl), administered around the palmar nerves at the level of the base of the proximal sesamoid bones, can improve naturally occurring lameness that can be improved or abolished with a basilar sesamoid nerve block performed using lidocaine HCl and to compare the change in gait produced using lidocaine to the change in gait produced using ketamine by using objective lameness assessment. Experimental trial using research horses with naturally occurring lameness. Seven horses, chronically lame on a thoracic limb, were chosen for the study. A wireless, inertial, sensor-based, motion analysis system was used to evaluate lameness before and after administration of 2% lidocaine and later, before and after administration of 3% ketamine over the palmar digital nerves at the base of the proximal sesamoid bones (a basilar sesamoid nerve block) at 5 min intervals for 30 min. Lameness scores obtained before and after administration of lidocaine and ketamine HCl were compared using repeated measures analysis. Gait significantly improved after basilar sesamoid nerve blocks using 2% lidocaine, but gait did not significantly improve after performing the same nerve block using 3% ketamine HCl. Ketamine (3%) administered perineurally for regional anaesthesia of the digit does not desensitise the digit to the same extent as does lidocaine and thus 3% ketamine appears to have no value as a local anaesthetic agent for diagnostic regional anaesthesia. © 2013 EVJ Ltd.
The international seismological observing period in Africa
Engdahl, E.R.; Bergman, Eric A.
1992-01-01
The International Seismological Observing Period (ISOP) is a specific time interval designated for enhanced international cooperation in the collection and dissemination of observatory measurements from the global seismographic network. The primary purpose of the ISOP is to strengthen the international infrastructure that supports current seismological practice and increase the cooperation among nations that operate seismological observatories. Measurements, reported by the existing global network and compiled by agencies such as the International Seismological Centre (ISC), are providing new information about earthquakes and the structure of the Earth of fundamental importance to the Earth sciences. However, these data represent but a small fraction of the information contained in the seismograms. One of the goals of the ISOP is to collect improved sets of data. In particular, the measurement and reporting of later-arriving phases, during a fixed ISOP period, from earthquakes selected for detailed observation by the cooperating stations will be encouraged. The use of advanced, digital instrumentation provides an unprecedented opportunity for enhancing the methods of seismogram interpretation and seismic parameter extraction, by the implementation of digital processing methods at seismic observatories worldwide. It must be ensured that this new information will be available to the entire seismological community. It is believed that this purpose is best served with an ISOP that promotes increased on-site processing at digital stations in Africa and elsewhere. Improvements in seismology require truly international cooperation and the educational aspects of seismological practice form one of the goals of the ISOP. Thus, workshops will be needed in Africa to train analysts in ISOP procedures and to introduce them to modern techniques and applications of the data. Participants will, thus, benefit from theoretical results and practical experience that are of direct relevance to their own work. ?? 1992.
Digital Reef Rugosity Estimates Coral Reef Habitat Complexity
Dustan, Phillip; Doherty, Orla; Pardede, Shinta
2013-01-01
Ecological habitats with greater structural complexity contain more species due to increased niche diversity. This is especially apparent on coral reefs where individual coral colonies aggregate to give a reef its morphology, species zonation, and three dimensionality. Structural complexity is classically measured with a reef rugosity index, which is the ratio of a straight line transect to the distance a flexible chain of equal length travels when draped over the reef substrate; yet, other techniques from visual categories to remote sensing have been used to characterize structural complexity at scales from microhabitats to reefscapes. Reef-scale methods either lack quantitative precision or are too time consuming to be routinely practical, while remotely sensed indices are mismatched to the finer scale morphology of coral colonies and reef habitats. In this communication a new digital technique, Digital Reef Rugosity (DRR) is described which utilizes a self-contained water level gauge enabling a diver to quickly and accurately characterize rugosity with non-invasive millimeter scale measurements of coral reef surface height at decimeter intervals along meter scale transects. The precise measurements require very little post-processing and are easily imported into a spreadsheet for statistical analyses and modeling. To assess its applicability we investigated the relationship between DRR and fish community structure at four coral reef sites on Menjangan Island off the northwest corner of Bali, Indonesia and one on mainland Bali to the west of Menjangan Island; our findings show a positive relationship between DRR and fish diversity. Since structural complexity drives key ecological processes on coral reefs, we consider that DRR may become a useful quantitative community-level descriptor to characterize reef complexity. PMID:23437380
Digital reef rugosity estimates coral reef habitat complexity.
Dustan, Phillip; Doherty, Orla; Pardede, Shinta
2013-01-01
Ecological habitats with greater structural complexity contain more species due to increased niche diversity. This is especially apparent on coral reefs where individual coral colonies aggregate to give a reef its morphology, species zonation, and three dimensionality. Structural complexity is classically measured with a reef rugosity index, which is the ratio of a straight line transect to the distance a flexible chain of equal length travels when draped over the reef substrate; yet, other techniques from visual categories to remote sensing have been used to characterize structural complexity at scales from microhabitats to reefscapes. Reef-scale methods either lack quantitative precision or are too time consuming to be routinely practical, while remotely sensed indices are mismatched to the finer scale morphology of coral colonies and reef habitats. In this communication a new digital technique, Digital Reef Rugosity (DRR) is described which utilizes a self-contained water level gauge enabling a diver to quickly and accurately characterize rugosity with non-invasive millimeter scale measurements of coral reef surface height at decimeter intervals along meter scale transects. The precise measurements require very little post-processing and are easily imported into a spreadsheet for statistical analyses and modeling. To assess its applicability we investigated the relationship between DRR and fish community structure at four coral reef sites on Menjangan Island off the northwest corner of Bali, Indonesia and one on mainland Bali to the west of Menjangan Island; our findings show a positive relationship between DRR and fish diversity. Since structural complexity drives key ecological processes on coral reefs, we consider that DRR may become a useful quantitative community-level descriptor to characterize reef complexity.
Linear Dimensional Stability of Irreversible Hydrocolloid Materials Over Time.
Garrofé, Analía B; Ferrari, Beatriz A; Picca, Mariana; Kaplan, Andrea E
2015-12-01
The aim of this study was to evaluate the linear dimensional stability of different irreversible hydrocolloid materials over time. A metal mold was designed with custom trays made of thermoplastic sheets (Sabilex, sheets 0.125 mm thick). Perforations were made in order to improve retention of the material. Five impressions were taken with each of the following: Kromopan 100 (LASCOD) [AlKr], which has dimensional stability of 100 hours, and Phase Plus (ZHERMACK) [AlPh], which has dimensional stability of 48 hours. Standardized digital photographs were taken at different time intervals (0, 15, 30, 45, 60, 120 minutes; 12, 24 and 96 hours), using an "ad-hoc" device. The images were analyzed with software (UTHSCSA Image Tool) by measuring the distance between intersection of the lines previously made at the top of the mold. The results were analyzed by ANOVA for repeated measures. Initial and final values were (mean and standard deviation): AlKr: 16.44 (0.22) and 16.34 (0.11), AlPh: 16.40 (0.06) and 16.18 (0.06). Statistical evaluation showed significant effect of material and time factors. Under the conditions in this study, time significantly affects the linear dimensional stability of irreversible hydrocolloid materials. Sociedad Argentina de Investigación Odontológica.
Frenken, Marius; Berti, Stefan
2018-04-01
Working memory enables humans to maintain selected information for cognitive processes and ensures instant access to the memorized contents. Theories suggest that switching the focus of attention between items within working memory realizes the access. This is reflected in object-switching costs in response times when the item for the task processing is to be changed. Another correlate of attentional allocation in working memory is the P3a-component of the human event-related potential. The aim of this study was to demonstrate that switching of attention within working memory is a separable processing step. Participants completed a cued memory-updating task in which they were instructed to update one memory item at a time out of a memory list of four digits by applying a mathematical operation indicated by a target sign. The hypotheses predicted (1) prolonged updating times in switch (different item compared to previous trial) versus repetition trials (same item), (2) an influence of cues (valid/neutral) presented before the mathematical target on switching costs, and (3) that the P3a-component is more pronounced in the cue-target interval in the valid cue condition and more pronounced in the post-target interval in the neutral cue condition. A student's t-test verified the first hypothesis, repeated-measurement analyses of variance demonstrated that hypotheses 2 and 3 should be rejected. Results suggest that switching of attention within working memory could not be separated from further processing steps and retro-cue benefits are not due to a head start of retrieval as well as that switch costs represent internal processes. Copyright © 2018 Elsevier B.V. All rights reserved.
Dhuhair, Sarah; Dennison, Joseph B; Yaman, Peter; Neiva, Gisele F
2015-04-01
To evaluate the effect of antacid swish in the salivary pH values and to monitor the pH changes in subjects with and without dental erosion after multiple acid challenge tests. 20 subjects with tooth erosion were matched in age and gender with 20 healthy controls according to specific inclusion/exclusion criteria. Baseline measures were taken of salivary pH, buffering capacity and salivary flow rate using the Saliva Check System. Subjects swished with Diet Pepsi three times at 10-minute intervals. Changes in pH were monitored using a digital pH meter at 0-, 5-, and 10- minute intervals and at every 5 minutes after the third swish until pH resumed baseline value or 45 minutes relapse. Swishing regimen was repeated on a second visit, followed by swishing with sugar-free liquid antacid (Mylanta Supreme). Recovery times were also recorded. Data was analyzed using independent t-tests, repeated measures ANOVA, and Fisher's exact test (α= 0.05). Baseline buffering capacity and flow rate were not significantly different between groups (P= 0.542; P= 0.2831, respectively). Baseline salivary pH values were similar between groups (P= 0.721). No significant differences in salivary pH values were found between erosion and non-erosion groups in response to multiple acid challenges (P= 0.695) or antacid neutralization (P= 0.861). Analysis of salivary pH recovery time revealed no significant differences between groups after acid challenges (P= 0.091) or after the use of antacid (P= 0.118). There was a highly significant difference in the survival curves of the two groups on Day 2, with the non-erosion group resolving significantly faster than the erosion group (P= 0.0086).
A new pterosaur tracksite from the Jurassic Summerville formation, near Ferron, Utah
Mickelson, Debra L.; Lockley, Martin G.; Bishop, John; Kirkland, James I.
2003-01-01
Pterosaur tracks (cf. Pteraichnus) from the Summerville Formation of the Ferron area of central Utah add to the growing record of Pteraichnus tracksites in the Late Jurassic Summerville Formation and time-equivalent, or near time-equivalent, deposits. The site is typical in revealing high pterosaur track densities, but low ichnodiversity suggesting congregations or “flocks” of many individuals. Footprint length varies from 2.0 to 7.0 cms. The ratio of well-preserved pes:manus tracks is about 1:3.4. This reflects a bias in favor of preservation of manus tracks due to the greater weight-bearing role of the front limbs, as noted in other pterosaur track assemblages. The sample also reveals a number of well-preserved trackways including one suggestive of pes-only progression that might be associated with take off or landing, and another that shows pronounced lengthening of stride indicating acceleration.One well-preserved medium-sized theropod trackway (Therangospodus) and other larger theropod track casts (cf. Megalosauripus) are associated with what otherwise appears to be a nearly monospecific pterosaur track assemblage. However, traces of a fifth pes digit suggest some tracks are of rhamphorynchoid rather than pterodactyloid origin, as usually inferred for Pteraichnus. The tracks occur at several horizons in a thin stratigraphic interval of ripple marked sandstones and siltstones. Overall the assemblage is similar to others found in the same time interval in the Western Interior from central and eastern Utah through central and southern Wyoming, Colorado, northeastern Arizona, and western Oklahoma. This vast “Pteraichnusichnofacies,” with associated saurischian tracks, remains the only ichnological evidence of pre-Cretaceous pterosaurs in North America and sheds important light on the vertebrate ecology of the Summerville Formation and contiguous deposits.
Petroleum system modeling of the western Canada sedimentary basin - isopach grid files
Higley, Debra K.; Henry, Mitchell E.; Roberts, Laura N.R.
2005-01-01
This publication contains zmap-format grid files of isopach intervals that represent strata associated with Devonian to Holocene petroleum systems of the Western Canada Sedimentary Basin (WCSB) of Alberta, British Columbia, and Saskatchewan, Canada. Also included is one grid file that represents elevations relative to sea level of the top of the Lower Cretaceous Mannville Group. Vertical and lateral scales are in meters. The age range represented by the stratigraphic intervals comprising the grid files is 373 million years ago (Ma) to present day. File names, age ranges, formation intervals, and primary petroleum system elements are listed in table 1. Metadata associated with this publication includes information on the study area and the zmap-format files. The digital files listed in table 1 were compiled as part of the Petroleum Processes Research Project being conducted by the Central Energy Resources Team of the U.S. Geological Survey, which focuses on modeling petroleum generation, 3 migration, and accumulation through time for petroleum systems of the WCSB. Primary purposes of the WCSB study are to Construct the 1-D/2-D/3-D petroleum system models of the WCSB. Actual boundaries of the study area are documented within the metadata; excluded are northern Alberta and eastern Saskatchewan, but fringing areas of the United States are included.Publish results of the research and the grid files generated for use in the 3-D model of the WCSB.Evaluate the use of petroleum system modeling in assessing undiscovered oil and gas resources for geologic provinces across the World.
Knox, D M
1999-06-01
To ascertain the effects of 1-, 1 1/2-, and 2-hour turning intervals on nursing home residents' skin over the sacrum and trochanters. (1) the higher the core body temperature, the higher the skin surface temperature; (2) the 2-hour turning interval would have significantly higher skin surface temperature; (3) there would be no relationship between skin surface temperature and interface pressure; and (4) the sacrum would have the lowest skin surface temperature. Modified Latin-square. For-profit nursing home. Convenience sample of 26 residents who scored < 3 on the Short Portable Mini-Mental Status Questionnaire and did not have (1) open wounds; (2) albumin levels < 3.3 mg/dL; (3) severe arthritis; (4) cortisone, anticoagulation, insulin therapy or 3 medications for hypertension; and/or (5) were totally bedridden. First Temp measured core temperature; a disposable thermistor temperature probe, skin temperature; and a digital interface pressure evaluator, the interface pressure. Negative correlation (r = -.33, P = .003) occurred between core body temperature and skin surface temperature. Skin surface temperature rose at the end of the 2-hour turning interval but was not significant (F = (2.68) = .73, P = .49). Weak negative relationship (r = -12, P = .29) occurred between skin surface temperature and interface pressure, and sacral skin surface temperature was significantly lower for the left trochanter only (F = (8.68) = 7.05, P = .002). Although hypotheses were not supported, more research is needed to understand how time in position and multiple chronic illnesses interact to affect skin pressure tolerance.
Joda, Tim; Brägger, Urs
2015-01-01
To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.
An Interactive Program on Digitizing Historical Seismograms
NASA Astrophysics Data System (ADS)
Xu, Y.; Xu, T.
2013-12-01
Retrieving information from historical seismograms is of great importance since they are considered the unique sources that provide quantitative information of historical earthquakes. Modern techniques of seismology require digital forms of seismograms that are essentially a sequence of time-amplitude pairs. However, the historical seismograms, after scanned into computers, are two dimensional arrays. Each element of the arrays contains the grayscale value or RGB value of the corresponding pixel. The problem of digitizing historical seismograms, referred to as converting historical seismograms to digital seismograms, can be formulated as an inverse problem that generating sequences of time-amplitude pairs from a two dimension arrays. This problem has infinite solutions. The algorithm for automatic digitization of historical seismogram presented considers several features of seismograms, including continuity, smoothness of the seismic traces as the prior information, and assumes that the amplitude is a single-valued function of time. An interactive program based on the algorithm is also presented. The program is developed using Matlab GUI and has both automatic and manual modality digitization. Users can easily switch between them, and try different combinations to get the optimal results. Several examples are given to illustrate the results of digitizing seismograms using the program, including a photographic record and a wide-angle reflection/refraction seismogram. Digitized result of the program (redrawn using Golden Software Surfer for high resolution image). (a) shows the result of automatic digitization, and (b) is the result after manual correction.
Mild, Kjell Hansson; Hardell, Lennart; Carlberg, Michael
2007-01-01
Here we present the pooled analysis of 2 case-control studies on the association of brain tumours with mobile phone use. Use of analogue cellular phones increased the risk for acoustic neuroma by 5%, 95% confidence interval (CI) = 2-9% per 100 hrs of use. The risk increased for astrocytoma grade III-IV with latency period with highest estimates using >10-year time period from first use of these phone types. The risk increased per one year of use of analogue phones by 10%, 95% CI = 6-14%, digital phones by 11%, 95% CI = 6-16%, and cordless phones by 8%, 95% CI = 5-12%. For all studied phone types OR for brain tumours, mainly acoustic neuroma and malignant brain tumours, increased with latency period, especially for astrocytoma grade III-IV.
Stress and flow analyses of ultraviolet-curable resin during curing
NASA Astrophysics Data System (ADS)
Umezaki, Eisaku; Okano, Akira; Koyama, Hiroto
2014-06-01
The stress and flow generated in ultraviolet (UV)-curable resin during curing in molds were measured to investigate their relationship. The specimens were molds consisting of glass plates and acrylic bars, and UV-curable liquid resin. The specimens were illuminated from above with UV rays. Photoelastic and visual images were separately obtained at a constant time interval using cameras during curing. To help obtain the visual images, acrylic powder was mixed with the liquid resin. The stress was obtained from the photoelastic images by a digital photoelastic technique with phase stepping, and the flow was obtained from the visual images by a particle-tracking velocimetry technique. Results indicate that the stress generated in the UV-curable resin during curing depends on the degree of contact between the mold and the cured area of the resin, and is hardly related to the flow.
Automated detection of sperm whale sounds as a function of abrupt changes in sound intensity
NASA Astrophysics Data System (ADS)
Walker, Christopher D.; Rayborn, Grayson H.; Brack, Benjamin A.; Kuczaj, Stan A.; Paulos, Robin L.
2003-04-01
An algorithm designed to detect abrupt changes in sound intensity was developed and used to identify and count sperm whale vocalizations and to measure boat noise. The algorithm is a MATLAB routine that counts the number of occurrences for which the change in intensity level exceeds a threshold. The algorithm also permits the setting of a ``dead time'' interval to prevent the counting of multiple pulses within a single sperm whale click. This algorithm was used to analyze digitally sampled recordings of ambient noise obtained from the Gulf of Mexico using near bottom mounted EARS buoys deployed as part of the Littoral Acoustic Demonstration Center experiment. Because the background in these data varied slowly, the result of the application of the algorithm was automated detection of sperm whale clicks and creaks with results that agreed well with those obtained by trained human listeners. [Research supported by ONR.
Hurricane Harvey Building Damage Assessment Using UAV Data
NASA Astrophysics Data System (ADS)
Yeom, J.; Jung, J.; Chang, A.; Choi, I.
2017-12-01
Hurricane Harvey which was extremely destructive major hurricane struck southern Texas, U.S.A on August 25, causing catastrophic flooding and storm damages. We visited Rockport suffered severe building destruction and conducted UAV (Unmanned Aerial Vehicle) surveying for building damage assessment. UAV provides very high resolution images compared with traditional remote sensing data. In addition, prompt and cost-effective damage assessment can be performed regardless of several limitations in other remote sensing platforms such as revisit interval of satellite platforms, complicated flight plan in aerial surveying, and cloud amounts. In this study, UAV flight and GPS surveying were conducted two weeks after hurricane damage to generate an orthomosaic image and a DEM (Digital Elevation Model). 3D region growing scheme has been proposed to quantitatively estimate building damages considering building debris' elevation change and spectral difference. The result showed that the proposed method can be used for high definition building damage assessment in a time- and cost-effective way.
NASA Technical Reports Server (NTRS)
Kreplin, R. W.; Dohne, B.; Feldman, U.; Neupert, W. M.
1984-01-01
An account is given of a Get-Away-Special experiment flown on Space Shuttles 7 and 8 investigating the effect of the space environment on Shumann emulsions. Shumann emulsions, having low gelatin content and no protective gelatin overcoating, are useful detectors of ultraviolet radiation shorter than 2200 angstroms but are extremely sensitive to environmental conditions and handling. The instrument required no interface with the Shuttle. It was turned on by an aneroid switch at an altitude of 50,000 feet. After that, its operation was controlled completely by a CMOS digital controller. Each hour, two temperatures and one voltage were read and stored in a CMOS programmable read only memory. At intervals, valves were opened and closed to expose SO 652 film strips of three sensitivities to the cargo bay environment for various time periods. The design and operation of the instrument package is described.
High stability lasers for lidar and remote sensing
NASA Astrophysics Data System (ADS)
Heine, Frank; Lange, Robert; Seel, Stefan; Smutny, Berry
2017-11-01
Tesat-Spacecom is currently building a set flight models of frequency stabilized lasers for the ESA Missions AEOLUS and LTP. Lasers with low intensity noise in the kHz region and analogue tuning capabilities for frequency and output power are developed for the on board metrology of the LTP project, the precursor mission for LISA. This type of laser is internally stabilized by precise temperature control, approaching an ALLAN variance of 10-9 for 100 sec. It can be easily locked to external frequency references with <50kHz bandwidth. The Seed laser for the AEOLUS mission (wind LIDAR) is used as the master frequency reference and is stabilized internally by a optical cavity. It shows a 3* 10-11 Allan variance from time intervals 1 sec - 1000 sec. Furthermore it is step-tunable for calibration of the receiver instrument with a speed of GHz / sec by a digital command interface. Performance and environmental test results will be presented.
Yubero, Santiago; Larrañaga, Elisa; Villora, Beatriz; Navarro, Raúl
2017-10-05
The present study examines the relationship between different roles in cyberbullying behaviors (cyberbullies, cybervictims, cyberbullies-victims, and uninvolved) and self-reported digital piracy. In a region of central Spain, 643 (49.3% females, 50.7% males) students (grades 7-10) completed a number of self-reported measures, including cyberbullying victimization and perpetration, self-reported digital piracy, ethical considerations of digital piracy, time spent on the Internet, and leisure activities related with digital content. The results of a series of hierarchical multiple regression models for the whole sample indicate that cyberbullies and cyberbullies-victims are associated with more reports of digital piracy. Subsequent hierarchical multiple regression analyses, done separately for males and females, indicate that the relationship between cyberbullying and self-reported digital piracy is sustained only for males. The ANCOVA analysis show that, after controlling for gender, self-reported digital piracy and time spent on the Internet, cyberbullies and cyberbullies-victims believe that digital piracy is a more ethically and morally acceptable behavior than victims and uninvolved adolescents believe. The results provide insight into the association between two deviant behaviors.
Department of Defense Precise Time and Time Interval program improvement plan
NASA Technical Reports Server (NTRS)
Bowser, J. R.
1981-01-01
The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.
NASA Astrophysics Data System (ADS)
Chen, Chun-Chi; Hwang, Chorng-Sii; Lin, You-Ting; Liu, Keng-Chih
2015-12-01
This paper presents an all-digital CMOS pulse-shrinking mechanism suitable for time-to-digital converters (TDCs). A simple MOS capacitor is used as a pulse-shrinking cell to perform time attenuation for time resolving. Compared with a previous pulse-shrinking mechanism, the proposed mechanism provides an appreciably improved temporal resolution with high linearity. Furthermore, the use of a binary-weighted pulse-shrinking unit with scaled MOS capacitors is proposed for achieving a programmable resolution. A TDC involving the proposed mechanism was fabricated using a TSMC (Taiwan Semiconductor Manufacturing Company) 0.18-μm CMOS process, and it has a small area of nearly 0.02 mm2 and an integral nonlinearity error of ±0.8 LSB for a resolution of 24 ps.
Digital gate pulse generator for cycloconverter control
Klein, Frederick F.; Mutone, Gioacchino A.
1989-01-01
The present invention provides a digital gate pulse generator which controls the output of a cycloconverter used for electrical power conversion applications by determining the timing and delivery of the firing pulses to the switching devices in the cycloconverter. Previous gate pulse generators have been built with largely analog or discrete digital circuitry which require many precision components and periodic adjustment. The gate pulse generator of the present invention utilizes digital techniques and a predetermined series of values to develop the necessary timing signals for firing the switching device. Each timing signal is compared with a reference signal to determine the exact firing time. The present invention is significantly more compact than previous gate pulse generators, responds quickly to changes in the output demand and requires only one precision component and no adjustments.
Shavit, Itai; Brant, Rollin; Nijssen-Jordan, Cheri; Galbraith, Roger; Johnson, David W
2006-12-01
Assessment of dehydration in young children currently depends on clinical judgment, which is relatively inaccurate. By using digital videography, we developed a way to assess capillary-refill time more objectively. Our goal was to determine whether digitally measured capillary-refill time assesses the presence of significant dehydration (> or = 5%) in young children with gastroenteritis more accurately than conventional capillary refill and overall clinical assessment. We prospectively enrolled children with gastroenteritis, 1 month to 5 years of age, who were evaluated in a tertiary-care pediatric emergency department and judged by a triage nurse to be at least mildly dehydrated. Before any treatment, we measured the weight and digitally measured capillary-refill time of these children. Pediatric emergency physicians determined capillary-refill time by using conventional methods and degree of dehydration by overall clinical assessment by using a 7-point Likert scale. Postillness weight gain was used to estimate fluid deficit; beginning 48 hours after assessment, children were reweighed every 24 hours until 2 sequential weights differed by no more than 2%. We compared the accuracy of digitally measured capillary-refill time with conventional capillary refill and overall clinical assessment by determining sensitivities, specificities, likelihood ratios, and area under the receiver operator characteristic curves. A total of 83 patients were enrolled and had complete follow-up; 13 of these patients had significant dehydration (> or = 5% of body weight). The area under the receiver operator characteristic curves for digitally measured capillary-refill time and overall clinical assessment relative to fluid deficit (< 5% vs > or = 5%) were 0.99 and 0.88, respectively. Positive likelihood ratios were 11.7 for digitally measured capillary-refill time, 4.5 for conventional capillary refill, and 4.1 for overall clinical assessment. Results of this prospective cohort study suggest that digitally measured capillary-refill time more accurately predicts significant dehydration (> or = 5%) in young children with gastroenteritis than overall clinical assessment.
ERIC Educational Resources Information Center
Musser, Linda
2016-01-01
Research communications today are largely conducted by digital means. At this time, however, only a small percentage of these digital communiques are archived and preserved for future use. This article provides an overview of the challenge of this digital grey literature, a brief overview of digital archiving, and the role librarians and…
Broadband Seismic Array Observation along a ~2000-km-long Linear Profile in South China
NASA Astrophysics Data System (ADS)
Ai, Y.; Zhao, L.; Chen, L.; Zheng, T.; He, Y.; Jiang, M.
2010-12-01
In order to study the interior structure and geodynamic evolution of South China, we have started implementation of a linear seismic array observation in this region since December 2009. The linear array extends for ~2000 km from the northwestern continental interior all the way to the southeastern coastal area, across major tectonic units of South China including the Songpan-Ganze Orogenic Belt (SGOB) in the northwest, the Yangtze Craton (YzC) in the middle, and the Huanan Orogenic Belt (HOB) in the southeast. We plan to deploy a total of 200 broadband stations in the time period from December 2009 to June 2012. All the stations will be equipped with Guralp CMG-3ESP sensors and Ref-tek 130-1 or Ref-tek 72-A digitizers. The entire array observation includes three stages. In the time period from December 2009 to March 2011, 64 stations were deployed with a spatial interval of ~25 km from Chengdu city in Sichuan province in the west to Quanzhou city in Fujian province in the southeast of China. In the second stage, about 70 stations with a spatial interval of ~10 km will be deployed from Gonghe city in Qinghai province in the northwest to Chengdu city in the southeast in the time period from October 2010 to November 2011. In the last stage from April 2011 to June 2012, 66 stations with a spatial interval of ~25 km will be deployed to densify the station coverage along the Chengdu - Quanzhou segment of the profile. We have already analyzed the seismic data collected at the 64 stations using receiver function methods. Our preliminary results show an obvious W-E variation in the crustal thickness of the region. In particular, from inland to offshore of the Fujian Province the crustal thickness decreases, whereas the Poisson's ratio increases. These may indicate decreasing SiO2 and increasing calc-alkaline contents in the crust. The receiver function data also reveal a coherent structure of the 410-km and 660-km discontinuities along the observation profile. ACKNOWLEDGMENTS We acknowledge the financial support of SinoProbe under Grant SinoProbe-02-03
The radiology digital dashboard: effects on report turnaround time.
Morgan, Matthew B; Branstetter, Barton F; Lionetti, David M; Richardson, Jeremy S; Chang, Paul J
2008-03-01
As radiology departments transition to near-complete digital information management, work flows and their supporting informatics infrastructure are becoming increasingly complex. Digital dashboards can integrate separate computerized information systems and summarize key work flow metrics in real time to facilitate informed decision making. A PACS-integrated digital dashboard function designed to alert radiologists to their unsigned report queue status, coupled with an actionable link to the report signing application, resulted in a 24% reduction in the time between transcription and report finalization. The dashboard was well received by radiologists who reported high usage for signing reports. Further research is needed to identify and evaluate other potentially useful work flow metrics for inclusion in a radiology clinical dashboard.
Gennaro, G; Ballaminut, A; Contento, G
2017-09-01
This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.
2011-01-01
Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757
Real time digital propulsion system simulation for manned flight simulators
NASA Technical Reports Server (NTRS)
Mihaloew, J. R.; Hart, C. E.
1978-01-01
A real time digital simulation of a STOL propulsion system was developed which generates significant dynamics and internal variables needed to evaluate system performance and aircraft interactions using manned flight simulators. The simulation ran at a real-to-execution time ratio of 8.8. The model was used in a piloted NASA flight simulator program to evaluate the simulation technique and the propulsion system digital control. The simulation is described and results shown. Limited results of the flight simulation program are also presented.
Recursive Algorithms for Real-Time Digital CR-RCn Pulse Shaping
NASA Astrophysics Data System (ADS)
Nakhostin, M.
2011-10-01
This paper reports on recursive algorithms for real-time implementation of CR-(RC)n filters in digital nuclear spectroscopy systems. The algorithms are derived by calculating the Z-transfer function of the filters for filter orders up to n=4 . The performances of the filters are compared with the performance of the conventional digital trapezoidal filter using a noise generator which separately generates pure series, 1/f and parallel noise. The results of our study enable one to select the optimum digital filter for different noise and rate conditions.
Digital data storage systems, computers, and data verification methods
Groeneveld, Bennett J.; Austad, Wayne E.; Walsh, Stuart C.; Herring, Catherine A.
2005-12-27
Digital data storage systems, computers, and data verification methods are provided. According to a first aspect of the invention, a computer includes an interface adapted to couple with a dynamic database; and processing circuitry configured to provide a first hash from digital data stored within a portion of the dynamic database at an initial moment in time, to provide a second hash from digital data stored within the portion of the dynamic database at a subsequent moment in time, and to compare the first hash and the second hash.
Zhang, Lu; Ouyang, Xing; Shao, Xiaopeng; Zhao, Jian
2016-06-27
Performance degradation induced by the DC components at the output of real-time analogue-to-digital converter (ADC) is experimentally investigated for optical fast-OFDM receiver. To compensate this degradation, register transfer level (RTL) circuits for real-time digital DC blocker with 20GS/s throughput are proposed and implemented in field programmable gate array (FPGA). The performance of the proposed real-time digital DC blocker is experimentally investigated in a 15Gb/s optical fast-OFDM system with intensity modulation and direct detection over 40 km standard single-mode fibre. The results show that the fixed-point DC blocker has negligible performance penalty compared to the offline floating point one, and can overcome the error floor of the fast OFDM receiver caused by the DC components from the real-time ADC output.
Prediction of Occult Invasive Disease in Ductal Carcinoma in Situ Using Deep Learning Features.
Shi, Bibo; Grimm, Lars J; Mazurowski, Maciej A; Baker, Jay A; Marks, Jeffrey R; King, Lorraine M; Maley, Carlo C; Hwang, E Shelley; Lo, Joseph Y
2018-03-01
The aim of this study was to determine whether deep features extracted from digital mammograms using a pretrained deep convolutional neural network are prognostic of occult invasive disease for patients with ductal carcinoma in situ (DCIS) on core needle biopsy. In this retrospective study, digital mammographic magnification views were collected for 99 subjects with DCIS at biopsy, 25 of which were subsequently upstaged to invasive cancer. A deep convolutional neural network model that was pretrained on nonmedical images (eg, animals, plants, instruments) was used as the feature extractor. Through a statistical pooling strategy, deep features were extracted at different levels of convolutional layers from the lesion areas, without sacrificing the original resolution or distorting the underlying topology. A multivariate classifier was then trained to predict which tumors contain occult invasive disease. This was compared with the performance of traditional "handcrafted" computer vision (CV) features previously developed specifically to assess mammographic calcifications. The generalization performance was assessed using Monte Carlo cross-validation and receiver operating characteristic curve analysis. Deep features were able to distinguish DCIS with occult invasion from pure DCIS, with an area under the receiver operating characteristic curve of 0.70 (95% confidence interval, 0.68-0.73). This performance was comparable with the handcrafted CV features (area under the curve = 0.68; 95% confidence interval, 0.66-0.71) that were designed with prior domain knowledge. Despite being pretrained on only nonmedical images, the deep features extracted from digital mammograms demonstrated comparable performance with handcrafted CV features for the challenging task of predicting DCIS upstaging. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Schepke, Ulf; Meijer, Henny J A; Kerdijk, Wouter; Cune, Marco S
2015-09-01
Digital impression-making techniques are supposedly more patient friendly and less time-consuming than analog techniques, but evidence is lacking to substantiate this assumption. The purpose of this in vivo within-subject comparison study was to examine patient perception and time consumption for 2 complete-arch impression-making methods: a digital and an analog technique. Fifty participants with a single missing premolar were included. Treatment consisted of implant therapy. Three months after implant placement, complete-arch digital (Cerec Omnicam; Sirona) and analog impressions (semi-individual tray, Impregum; 3M ESPE) were made, and the participant's opinion was evaluated with a standard questionnaire addressing several domains (inconvenience, shortness of breath, fear of repeating the impression, and feelings of helplessness during the procedure) with the visual analog scale. All participants were asked which procedure they preferred. Operating time was measured with a stopwatch. The differences between impressions made for maxillary and mandibular implants were also compared. The data were analyzed with paired and independent sample t tests, and effect sizes were calculated. Statistically significant differences were found in favor of the digital procedure regarding all subjective domains (P<.001), with medium to large effect sizes. Of all the participants, over 80% preferred the digital procedure to the analog procedure. The mean duration of digital impression making was 6 minutes and 39 seconds (SD=1:51) versus 12 minutes and 13 seconds (SD=1:24) for the analog impression (P<.001, effect size=2.7). Digital impression making for the restoration of a single implant crown takes less time than analog impression making. Furthermore, participants preferred the digital scan and reported less inconvenience, less shortness of breath, less fear of repeating the impression, and fewer feelings of helplessness during the procedure. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Camardella, Leonardo Tavares; Sá, Maiara da Silva Bezerra; Guimarães, Luciana Campos; Vilella, Beatriz de Souza; Vilella, Oswaldo de Vasconcellos
2018-03-01
The aim of this study was to verify the accuracy of preformed wire shape templates on plaster models and those of customized digital arch form diagrams on digital models. Twenty pairs of dental plaster models were randomly selected from the archives of the Department of Orthodontics of Federal Fluminense University, Niterói, Rio de Janeiro, Brazil. All plaster model samples were scanned in a plaster model scanner to create the respective digital models. Three examiners defined the arch form on the mandibular arch of these models by selecting the ideal preformed wire shape template on each plaster model or by making a customized digital arch form on the digital models using a digital arch form customization tool. These 2 arch forms were superimposed by the best-fit method. The greatest differences in the 6 regions on the superimposed arches were evaluated. Each examiner presented a descriptive analysis with the means, standard deviation, and minimum and maximum intervals of the differences on the superimpositions. Intraclass correlation coefficient and paired t tests were used to evaluate the accuracy of the superimpositions. Among the 6 regions analyzed in the superimpositions, the largest differences in the anterior and premolar regions were considered clinically insignificant, whereas the largest differences in the right molar region, especially the second molar area, were considered clinically significant by all 3 examiners. The intraclass correlation coefficients showed a weak correlation in the premolar region and moderate correlations in the anterior and molar regions. The paired t test showed statistically significant differences in the left anterior and premolar regions. The superimpositions between the arch forms on plaster and digital models were considered accurate, and the differences were not clinically significant, with the exception of the second molar area. Despite the favorable results, the requirement of correcting some software problems may hamper the transition from plaster to digital models. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Burau, J.R.; Simpson, M.R.; Cheng, R.T.
1993-01-01
Water-velocity profiles were collected at the west end of Carquinez Strait, San Francisco Bay, California, from March to November 1988, using an acoustic Doppler current profiler (ADCP). These data are a series of 10-minute-averaged water velocities collected at 1-meter vertical intervals (bins) in the 16.8-meter water column, beginning 2.1 meters above the estuary bed. To examine the vertical structure of the horizontal water velocities, the data are separated into individual time-series by bin and then used for time-series plots, harmonic analysis, and for input to digital filters. Three-dimensional graphic renditions of the filtered data are also used in the analysis. Harmonic analysis of the time-series data from each bin indicates that the dominant (12.42 hour or M2) partial tidal currents reverse direction near the bottom, on average, 20 minutes sooner than M2 partial tidal currents near the surface. Residual (nontidal) currents derived from the filtered data indicate that currents near the bottom are pre- dominantly up-estuary during the neap tides and down-estuary during the more energetic spring tides.
NASA Astrophysics Data System (ADS)
Matsuzaki, F.; Yoshikawa, N.; Tanaka, M.; Fujimaki, A.; Takai, Y.
2003-10-01
Recently many single flux quantum (SFQ) logic circuits containing several thousands of Josephson junctions have been designed successfully by using digital domain simulation based on the hard ware description language (HDL). In the present HDL-based design of SFQ circuits, a structure-level HDL description has been used, where circuits are made up of basic gate cells. However, in order to analyze large-scale SFQ digital systems, such as a microprocessor, more higher-level circuit abstraction is necessary to reduce the circuit simulation time. In this paper we have investigated the way to describe functionality of the large-scale SFQ digital circuits by a behavior-level HDL description. In this method, the functionality and the timing of the circuit block is defined directly by describing their behavior by the HDL. Using this method, we can dramatically reduce the simulation time of large-scale SFQ digital circuits.
Topographic map of the Coronae Montes region of Mars - MTM 500k -35/087E OMKTT
Rosiek, Mark R.; Redding, Bonnie L.; Galuszca, Donna M.
2005-01-01
This map is part of a series of topographic maps of areas of special scientific interest on Mars. The topography was compiled photogrammetrically using Viking Orbiter stereo image pairs. The contour interval is 250 m. Horizontal and vertical control was established using the USGS Mars Digital Image Model 2.0 (MDIM 2.0) and data from the Mars Orbiter Laser Altimeter (MOLA).
Topographic Map of the Northeast Ascraeus Mons Region of Mars - MTM 500k 15/257E OMKT
,
2004-01-01
This map is part of a series of topographic maps of areas of special scientific interest on Mars. The topography was compiled photogrammetically using Viking Orbiter stereo image pairs. The contour interval is 250 meters. Horizontal and vertical control was established using the USGS Mars Digital Image Model 2.0 (MDIM 2.0) and data from the Mars Orbiter Laser Altimeter (MOLA).
Topographic Map of the Northwest Ascraeus Mons Region of Mars - MTM 500k 15/252E OMKT
,
2004-01-01
This map is part of a series of topographic maps of areas of special scientific interest on Mars. The topography was compiled photogrammetically using Viking Orbiter stereo image pairs. The contour interval is 250 meters. Horizontal and vertical control was established using the USGS Mars Digital Image Model 2.0 (MDIM 2.0) and data from the Mars Orbiter Laser Altimeter (MOLA).
Topographic Map of the Southeast Ascraeus Mons Region of Mars - MTM 500k 10/257E OMKT
,
2004-01-01
This map is part of a series of topographic maps of areas of special scientific interest on Mars. The topography was compiled photogrammetically using Viking Orbiter stereo image pairs. The contour interval is 250 meters. Horizontal and vertical control was established using the USGS Mars Digital Image Model 2.0 (MDIM 2.0) and data from the Mars Orbiter Laser Altimeter (MOLA).
Topographic Map of the Southwest Ascraeus Mons Region of Mars - MTM 500k 10/252E OMKT
,
2004-01-01
This map is part of a series of topographic maps of areas of special scientific interest on Mars. The topography was compiled photogrammetically using Viking Orbiter stereo image pairs. The contour interval is 250 meters. Horizontal and vertical control was established using the USGS Mars Digital Image Model 2.0 (MDIM 2.0) and data from the Mars Orbiter Laser Altimeter (MOLA).
Accurate formula for gaseous transmittance in the infrared.
Gibson, G A; Pierluissi, J H
1971-07-01
By considering the infrared transmittance model of Zachor as the equation for an elliptic cone, a quadratic generalization is proposed that yields significantly greater computational accuracy. The strong-band parameters are obtained by iterative nonlinear, curve-fitting methods using a digital computer. The remaining parameters are determined with a linear least-squares technique and a weighting function that yields better results than the one adopted by Zachor. The model is applied to CO(2) over intervals of 50 cm(-1) between 550 cm(-1) and 9150 cm(-1) and to water vapor over similar intervals between 1050 cm(-1) and 9950 cm(-1), with mean rms deviations from the original data being 2.30 x 10(-3) and 1.83 x 10(-3), respectively.
Ratio-based lengths of intervals to improve fuzzy time series forecasting.
Huarng, Kunhuang; Yu, Tiffany Hui-Kuang
2006-04-01
The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.
Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan
2014-01-01
Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750
BPSK Demodulation Using Digital Signal Processing
NASA Technical Reports Server (NTRS)
Garcia, Thomas R.
1996-01-01
A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.
Goracci, Cecilia; Franchi, Lorenzo; Vichi, Alessandro; Ferrari, Marco
2016-08-01
The interest on intraoral scanners for digital impressions has been growing and new devices are continuously introduced on the market. It is timely to verify whether the several scanners proposed for full-arch digital impressions have been tested under clinical conditions for validity, repeatability, reproducibility, as well as for time efficiency, and patient acceptance. An electronic search of the literature was conducted through PubMed, Scopus, Cochrane Library, Web of Science, and Embase, entering the query terms 'digital impression', 'intraoral digital impression', 'intraoral scanning', 'intraoral scanner', 'intraoral digital scanner', combined by the Boolean operator 'OR'. No language or time limitation was applied. Only studies where digital full-arch impressions had been recorded intraorally were considered. In only eight studies full-arch scans had been performed intraorally. Only four studies reported data on validity, repeatability, reproducibility of digital measurements and their samples were limited to subjects in complete permanent dentition. Only two intraoral scanners, Lava COS and iTero, were tested. Scanning times were measured in six studies and varied largely. Patients' acceptance of intraoral scanning was evaluated in four studies, but it was not specifically assessed for children. The scientific evidence so far collected on intraoral scanning is neither exhaustive, nor up-to-date. Data from full-arch scans performed in children should be collected. For a meaningful assessment of time efficiency, agreement should be reached on the procedural steps to be included in the computation of scanning time. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Interresponse Time Structures in Variable-Ratio and Variable-Interval Schedules
ERIC Educational Resources Information Center
Bowers, Matthew T.; Hill, Jade; Palya, William L.
2008-01-01
The interresponse-time structures of pigeon key pecking were examined under variable-ratio, variable-interval, and variable-interval plus linear feedback schedules. Whereas the variable-ratio and variable-interval plus linear feedback schedules generally resulted in a distinct group of short interresponse times and a broad distribution of longer…
Role of plaque in the clearance of salivary sucrose and its influence on salivary ph.
Kumar, A; Hedge, R; Dixit, U
2011-01-01
The prevalence of dental caries in children, in India, is higher than many of the industrialized countries. The sugar most commonly associated with dental caries is sucrose, as the microorganisms in the dental plaque have the ability to convert this dietary constituent into various organic acids. This study was conducted to study the effect of the presence of plaque on the salivary clearance of sucrose and to study the effect of the presence of plaque on salivary pH, following sucrose clearance. Salivary sucrose determination was done by using the anthrone technique. A Digital MHOS pH meter estimated the salivary pH. Presence of plaque increased the salivary sucrose clearance time and decreased the salivary pH at various time intervals. The microbial etiology of dental caries is the dynamic relationship among the dental plaque microbiota, dietary carbohydrates, saliva and pH lowering, and the cariogenic potential of the dental plaque. Caries occur preferentially in the dentition sites characterized by high exposure to carbohydrate and diminished salivary effect.
Dolphin Sounds-Inspired Covert Underwater Acoustic Communication and Micro-Modem
Qiao, Gang; Liu, Songzuo; Bilal, Muhammad
2017-01-01
A novel portable underwater acoustic modem is proposed in this paper for covert communication between divers or underwater unmanned vehicles (UUVs) and divers at a short distance. For the first time, real dolphin calls are used in the modem to realize biologically inspired Covert Underwater Acoustic Communication (CUAC). A variety of dolphin whistles and clicks stored in an SD card inside the modem helps to realize different biomimetic CUAC algorithms based on the specified covert scenario. In this paper, the information is conveyed during the time interval between dolphin clicks. TMS320C6748 and TLV320AIC3106 are the core processors used in our unique modem for fast digital processing and interconnection with other terminals or sensors. Simulation results show that the bit error rate (BER) of the CUAC algorithm is less than 10−5 when the signal to noise ratio is over ‒5 dB. The modem was tested in an underwater pool, and a data rate of 27.1 bits per second at a distance of 10 m was achieved. PMID:29068363
Pozz, Agostino; Corte, Angelo Della; Lakis, Mustapha A El; Jeong, HeonJae
2016-01-01
Digital breast tomosynthesis (DBT) as a breast cancer screening modality, through generation of three dimensional images during standard mammographic compression, can reduce interference from breast tissue overlap, increasing conspicuity of invasive cancers while concomitantly reducing falsepositive results. We here conducted a systematic review on previous studies to synthesize the evidence of DBT efficacy, eventually 18 articles being included in the analysis. The most commonly emerging topics were advantages of DBT screening tool in terms of recall rates, cancer detection rates and costeffectiveness, preventing unnecessary burdens on women and the healthcare system. Further research is needed to evaluate the potential impact of DBT on longerterm outcomes, such as interval cancer rates and mortality, to better understand the broader clinical and economic implications of its adoption.
NASA Technical Reports Server (NTRS)
Hoffer, R. M. (Principal Investigator)
1980-01-01
To facilitate comparison between the four different spatial resolution of the NS-001 MSS data sets, a supervised approach was taken in defining training blocks for each of the different cover types. The training fields representing each cover type category were grouped and this group was clustered to determine the individual spectral classes within each cover type category which would effectively characterize the entire test site. Graphs show the variation in spectral response level with respect to distance in the across track dimension for four sampling intervals. Radar digitization procedures were developd. Flight characteristics and parameters for digitization of radar imagery are tabulated. The statement of work for phase 3 was reviewed and modifications were suggested to meet funding reduction.
Pioneer Venus Orbiter planar retarding potential analyzer plasma experiment
NASA Technical Reports Server (NTRS)
Knudsen, W. C.; Bakke, J.; Spenner, K.; Novak, V.
1980-01-01
The retarding potential analyzer (RPA) on the Pioneer Venus Orbiter Mission measures most of the thermal plasma parameters within and near the Venusian ionosphere. Parameters include total ion concentration, concentrations of the more abundant ions, ion temperatures, ion drift velocity, electron temperature, and low-energy (0-50 eV) electron distribution function. Several functions not previously used in RPA's were developed and incorporated into this instrument to accomplish these measurements on a spinning spacecraft with a small bit rate. The more significant functions include automatic electrometer ranging with background current compensation; digital, quadratic retarding potential step generation for the ion and low-energy electron scans; a current sampling interval of 2 ms throughout all scans; digital logic inflection point detection and data selection; and automatic ram direction detection.
Prediction of fracture profile using digital image correlation
NASA Astrophysics Data System (ADS)
Chaitanya, G. M. S. K.; Sasi, B.; Kumar, Anish; Babu Rao, C.; Purnachandra Rao, B.; Jayakumar, T.
2015-04-01
Digital Image Correlation (DIC) based full field strain mapping methodology is used for mapping strain on an aluminum sample subjected to tensile deformation. The local strains on the surface of the specimen are calculated at different strain intervals. Early localization of strain is observed at a total strain of 0.050ɛ; itself, whereas a visually apparent localization of strain is observed at a total strain of 0.088ɛ;. Orientation of the line of fracture (12.0°) is very close to the orientation of locus of strain maxima (11.6°) computed from the strain mapping at 0.063ɛ itself. These results show the efficacy of the DIC based method to predict the location as well as the profile of the fracture, at an early stage.
Comparison of Film and Digital Fundus Photographs in Eyes of Individuals with Diabetes Mellitus
Gangaputra, Sapna; Glassman, Adam R.; Aiello, Lloyd Paul; Bressler, Neil; Bressler, Susan B.; Danis, Ronald P.; Davis, Matthew D.
2011-01-01
Purpose. To compare grading of diabetic retinopathy (DR) and diabetic macular edema (DME) from stereoscopic film versus stereoscopic digital photographs obtained from a subset of Diabetic Retinopathy Clinical Research Network (DRCR.net) participants. Methods. In this photographic media comparison study, digital and film images were obtained at a single study visit from some of the subjects enrolled in active DRCR.net clinical study protocols. Digital camera systems and digital and film photographers were certified to obtain images according to standard procedures. Images were graded for DR severity and DME in a masked fashion by Fundus Photograph Reading Center (Madison, WI) graders. Agreement between gradings was assessed by calculating the percentage of agreement and κ statistics. Results. Images obtained with both film and digital media were submitted for 155 eyes of 96 study participants. On a nine-step Early Treatment Diabetic Retinopathy study DR severity scale, grading agreed exactly in 74%, and was within one step of agreement in 93%, with a weighted κ statistic of 0.82 (95% confidence interval [CI], 0.71–0.92). On a nine-step DME severity scale and three-step clinically significant macular edema (CSME) scale, grading agreed exactly in 39% and 88%, respectively, and within one step in 70% and 92% (weighted κ statistic, 0.44 [95% Cl, 0.34–0.54] and 0.72 [95% Cl, 0.55–0.90], respectively). Conclusions. Among clinical sites participating in the DRCR.net, agreement between film and digital images was substantial to almost perfect for DR severity level and moderate to substantial for DME and CSME severity levels, respectively. Replacement of film fundus images with digital images for DR severity level should not adversely affect clinical trial quality. (ClinicalTrials.gov numbers, NCT00367133, NCT00369486, NCT00444600, NCT00445003, NCT00709319.) PMID:21571677
McMahan, Zsuzsanna H; Wigley, Frederick M; Casciola-Rosen, Livia
2017-06-01
To evaluate whether scleroderma patients who are double-positive for anti-interferon-inducible protein 16 (anti-IFI-16) antibodies and anticentromere (anti-CENP) antibodies are at increased risk for significant digital vascular events relative to patients positive for anti-CENP antibodies alone. Sera from 165 scleroderma patients who tested positive for anti-CENP antibodies upon clinical evaluation were reassayed for both anti-CENP and anti-IFI-16 antibodies using enzyme-linked immunosorbent assay testing. Patients who were positive for anti-CENP antibodies alone were then compared to patients who were double-positive for both anti-IFI-16 and anti-CENP antibodies. The association between a history of significant digital vascular events (digital pits, ischemic digital ulcers, and/or gangrene) and double-positive antibody status was examined using chi-square tests. After completion of univariate analysis, multivariable analyses were done to adjust for clinically relevant covariates. Of the 165 anti-CENP antibody positive patients, 21 (12.7%) also had anti-IFI-16 antibodies. Patients who were double-positive for anti-CENP and anti-IFI-16 antibodies were more likely to have had digital pits, ischemic digital ulcers, and/or gangrene (P = 0.03). After adjustment for clinically relevant covariates (age, cutaneous subtype, disease duration, and smoking), double-positive patients remained at significantly higher odds of having severe Raynaud's phenomenon (odds ratio 3.5 [95% confidence interval 1.1-11.1]; P = 0.03). Scleroderma patients who are double-positive for antibodies recognizing CENP and IFI-16 are significantly more likely to have significant digital vascular events during the course of their disease. This study provides further evidence that anti-CENP and anti-IFI-16 antibodies are disease biomarkers that may be used for risk stratification of vascular events in scleroderma. © 2016, American College of Rheumatology.
Compiling Mercury relief map using several data sources
NASA Astrophysics Data System (ADS)
Zakharova, Maria; Lazarev, Evgeniy
2015-04-01
There are several data of Mercury topography obtained as the result of processing materials collected by two spacecrafts - the Mariner-10 and the MESSENGER during their Mercury flybys. The history of the visual mapping of the Mercury begins at the recent times as the first significant observations were made during the latter half of the 20th century, whereas today we have no data with 100% coverage for the entire surface of the Mercury except the global mosaic composed of the images acquired by MESSENGER. The Mercury relief map has been created with the help of four different types of data: - global mosaic with 100% coverage of Mercury's surface created by using MESSENGER orbital images (30% of the final map); - Digital Terrain Models obtained by the treating stereo images made during the Mariner 10's flybys (10% of the map) (Cook and Robinson, 2000); - Digital Terrain Models obtained from images acquired during the Messenger flybys (20% of the map) (F. Preusker et al., 2011); - the data sets produced by the MESSENGER Mercury Laser Altimeter (MLA) (40 % of the map). The main objective of this work is to collect, combine and process the existing data and then to merge them correctly for one single map compiling. The final map is created in the Lambert azimuthal Equal area projection and mainly shows the hypsometric features of the planet. It represents two hemispheres - western and eastern. In order not to divide data sources the eastern hemisphere takes an interval from 50 degrees east longitude to 130 degrees west longitude and the western one takes respectively the interval from 130 degrees west longitude to 50 degrees east longitude. References: Global mosaics of Mercury's surface. Available mosaics include one created prior to MESSENGER's orbital operations, high resolution versions that use MESSENGER's orbital images that are available in NASA's Planetary Data System (PDS) (http://messenger.jhuapl.edu/the_mission/mosaics.html). Cook, A.C., Robinson, M.S., 2000. Mariner 10 stereo image coverage of Mercury. J. Geophys. Res. 105, 9429-9443. Preusker, F., Oberst, J., Head, J.W., Watters, T.R., Robinson, M.S., Zuber, M.T., Solomon, S.C., 2010. Stereo topographic models of Mercury after three MESSENGER flybys. Planetary and Space Science 59 (2011), 1910-1917. The MLA is a time-of-flight laser rangefinder that uses direct detection and pulse-edge timing to determine precisely the range from the MESSENGER spacecraft to Mercury's surface (http://pds-geosciences.wustl.edu/missions/messenger/mla.htm).
One GHz digitizer for space based laser altimeter
NASA Technical Reports Server (NTRS)
Staples, Edward J.
1991-01-01
This is the final report for the research and development of the one GHz digitizer for space based laser altimeter. A feasibility model was designed, built, and tested. Only partial testing of essential functions of the digitizer was completed. Hybrid technology was incorporated which allows analog storage (memory) of the digitally sampled data. The actual sampling rate is 62.5 MHz, but executed in 16 parallel channels, to provide an effective sampling rate of one GHz. The average power consumption of the one GHz digitizer is not more than 1.5 Watts. A one GHz oscillator is incorporated for timing purposes. This signal is also made available externally for system timing. A software package was also developed for internal use (controls, commands, etc.) and for data communication with the host computer. The digitizer is equipped with an onboard microprocessor for this purpose.
Challenges in Diabetes Care: Can Digital Health Help Address Them?
Close, Kelly
2016-01-01
In Brief There is great enthusiasm for the potential of digital health solutions in medicine and diabetes to address key care challenges: patient and provider burden, lack of data to inform therapeutic decision-making, poor access to care, and costs. However, the field is still in its nascent days; many patients and providers do not currently engage with digital health tools, and for those who do, the burden is still often high. Over time, digital health has excellent potential to collect data more seamlessly, make collected data more useful, and drive better outcomes at lower costs in less time. But there is still much to prove. This review offers key background information on the current state of digital health in diabetes, six of the most promising digital health technologies and services, and the challenges that remain. PMID:27621530
Useful optical density range in film dosimetry: limitations due to noise and saturation.
González-López, Antonio
2007-08-07
The optical density (OD) range for the scanners used in film dosimetry is limited due to saturation and noise. As the OD increases, saturation causes the rate of change of the output with respect to the input to become smaller, while at the same time noise remains fairly constant or increases. The combined effect leads to a degradation of the signal-to-noise ratio (SNR) at high optical densities. In this study, the uncertainty in the OD measurement, d(m), is expressed as a function of the optical density d. The functional relationship obtained gives the amplitude w of an interval around d in which d(m) will be found with a given probability p. The relationship w = w(d, p) is later used to determine which OD ranges fulfil a set of requirements on w and p. As an application of the procedure, the noise and saturation characteristics of a commercial film digitizer system are measured. Their contribution to the uncertainties of the dosimetric procedure is reported, and the data are used to provide an optical density range for a given uncertainty and confidence level associated with the digitizer. These data can be further combined with the data from other sources of noise such as film noise in order to estimate the final uncertainty of the dosimetric process.
Mao, Yi-Ting; Mitchell, Peter; Churilov, Leonid; Dowling, Richard; Dong, Qiang; Yan, Bernard
2016-08-01
We aimed to evaluate early recanalization postintravenous (i.v.) tissue plasminogen activator (t-PA) by digital subtraction angiography (DSA) in acute ischemic stroke (AIS) with large vessel occlusion (LVO). We performed baseline CT angiography to identify LVO in AIS. Recanalization pre- and post-intra-arterial therapy (IAT) was categorized to none, partial, and global recanalization (GR). Modified Rankin Scale score ≤2 at 3 months was considered a favorable outcome. Among 1610 patients with AIS, 286 received IV t-PA. Of these, 55 patients with LVO were included. The median time from IV t-PA to DSA was 120 min (interquartile range, 79-152). Recanalization post-IV t-PA was observed in seven patients (12.7%). By occlusion sites, the recanalization rates were as follows: extracranial internal carotid artery 2 of 14 (14.3%); intracranial internal carotid artery 3 of 24 (12.5%); M1 of middle cerebral artery 3 of 39 (7.7%); M2 of middle cerebral artery 1 of 40 (2.5%); vertebral artery 0 of 4; and basilar artery 0 of 7. GR post-IAT was associated with favorable outcomes (odds ratio: 8.6; 95% confidence interval, 1.5-48.0; P = 0.014). Early recanalization assessed by DSA post-IV t-PA is rarely observed in acute ischemic stroke patients with LVO. © 2016 John Wiley & Sons Ltd.
2015-01-01
Purpose. There is a need for efficient self-tests of vision in patients with neovascular age-related macula degeneration. A new tablet/smartphone application aiming to meet this need is described and its performance is assessed in a longitudinal pilot study. Materials and Methods. The new MultiBit Test (MBT) employs segmented digits defined by rarebits, that is, receptive field-size bright dots briefly presented against a dark background. The number of rarebits per digit segment was varied in a cyclic fashion, in preset steps. There were no fixation demands. Twenty-eight patients with neovascular AMD of varying severity were monitored for an average of 30 weeks. Test scores were evaluated on an individual basis, by contrasting observed trends with the clinical status recorded at independently scheduled clinical examinations. Results. Serial plots of MBT results revealed gradual improvement after successful antineovascular treatment. Recurrences were signalled by gradual deteriorations of results. Test results remained stable during clinically stable time intervals. MBT results agreed well with clinical assessments whereas an acuity test performed at chance level. The MBT was well accepted by all subjects. Conclusions. The MBT appears to have a good potential for effective self-testing of vision in AMD and merits large-scale studies. Exploration of MBT performance with other forms of macula conditions may be worthwhile. PMID:26124958
Beglinger, Leigh J; Duff, Kevin; Allison, Jessica; Theriault, Danielle; O'Rourke, Justin J F; Leserman, Anne; Paulsen, Jane S
2010-07-01
Huntington disease (HD) is a neurodegenerative disease associated with cognitive, motor, and psychiatric deterioration over time. Although there is currently no cure for HD, there has been a surge of clinical trials available to patients with HD over the past 5 years. However, cognitive measures have generally been lacking from these trials. A brief, repeatable neuropsychological battery is needed to assess cognitive endpoints. The Repeatable Battery for the Assessment of Neuropsychological Status (RBANS) may be useful for assessing change in interventional studies or for clinical monitoring. A total of 38 patients with HD were assessed using the RBANS, other cognitive tests, and the standardized HD battery (Unified Huntington's Disease Rating Scale, UHDRS) at two clinic visits approximately 16 months apart. The RBANS Attention Index, as well as individual subtest scores on Coding, Digit Span, List Recognition, Figure Copy, and Figure Recall all declined significantly over this interval. Performance on the UHDRS cognitive tests (Symbol Digit Modalities; Stroop Color, and Stroop Word) also declined, as did functional capacity. Results suggest that cognitive changes were detected both on established cognitive tasks used in HD research and on the RBANS in patients with measurable functional decline. The RBANS provided additional information about other cognitive domains affected (e.g., memory) and may be a useful measure for tracking longitudinal change.
Reliability of shade selection using an intraoral spectrophotometer.
Witkowski, Siegbert; Yajima, Nao-Daniel; Wolkewitz, Martin; Strub, Jorge R
2012-06-01
In this study, we evaluate the accuracy and reproducibility of human tooth shade selection using a digital spectrophotometer. Variability among examiners and illumination conditions were tested for possible influence on measurement reproducibility. Fifteen intact anterior teeth of 15 subjects were evaluated for their shade using a digital spectrophotometer (Crystaleye, Olympus, Tokyo, Japan) by two examiners under the same light conditions representing a dental laboratory situation. Each examiner performed the measurement ten times on the labial surface of each tooth containing three evaluation sides (cervical, body, incisal). Commission International on Illumination color space values for L* (lightness), a* (red/green), and b* (yellow/blue) were obtained from each evaluated side. Examiner 2 repeated the measurements of the same subjects under different light conditions (i.e., a dental unit with a chairside lamp). To describe measurement precision, the mean color difference from the mean metric was used. The computed confidence interval (CI) value 5.228 (4.6598-5.8615) reflected (represented) the validity of the measurements. Least square mean analysis of the values obtained by examiners 1 and 2 or under different illumination conditions revealed no statistically significant differences (CI = 95%). Within the limits of the present study, the accuracy and reproducibility of dental shade selection using the tested spectrophotometer with respect to examiner and illumination conditions reflected the reliability of this device. This study suggests that the tested spectrophotometer can be recommended for the clinical application of shade selection.
Attention and working memory in elderly: the influence of a distracting environment.
Rodrigues, Pedro F S; Pandeirada, Josefa N S
2015-02-01
The present work investigated the effect of a distracting environment in the performance of attentional and working memory (WM) tasks in elderly participants. To this end, forty elderly performed two attentional tasks (simple reaction time and go/no-go tasks), and three WM tasks (arithmetic, memory for digits and sequences of letters and numbers). Each participant performed the tasks in a distracting and a non-distracting environment, with an interval of 14-21 days between sessions. The results revealed better performance in the attentional tasks when these were done in the non-distracting environment, as compared to when they were done in the distracting environment. Specifically, participants provided more accurate responses, fewer false alarms and omissions when responding in the non-distracting environment than when responding in the distracting environment. Participants were also faster at providing correct responses in the go/no-go task when it was performed in the non-distracting environment. As for the memory tasks, the effect of type of environment was significant only in the memory for digits in a forward direction task. Our data suggest the need to consider the potential damaging consequences of distracting environments when the elderly have to perform tasks that demand their attention. Specific examples of such situations are presented in the discussion (e.g., distracting effect of environment on medical and on psychological evaluations).
Three-dimensional (3D) GIS-based coastline change analysis and display using LIDAR series data
NASA Astrophysics Data System (ADS)
Zhou, G.
This paper presents a method to visualize and analyze topography and topographic changes on coastline area. The study area, Assantage Island Nation Seashore (AINS), is located along a 37-mile stretch of Assateague Island National Seashore in Eastern Shore, VA. The DEMS data sets from 1996 through 2000 for various time intervals, e.g., year-to-year, season-to-season, date-to-date, and a four year (1996-2000) are created. The spatial patterns and volumetric amounts of erosion and deposition of each part on a cell-by-cell basis were calculated. A 3D dynamic display system using ArcView Avenue for visualizing dynamic coastal landforms has been developed. The system was developed into five functional modules: Dynamic Display, Analysis, Chart analysis, Output, and Help. The Display module includes five types of displays: Shoreline display, Shore Topographic Profile, Shore Erosion Display, Surface TIN Display, and 3D Scene Display. Visualized data include rectified and co-registered multispectral Landsat digital image and NOAA/NASA ATM LIDAR data. The system is demonstrated using multitemporal digital satellite and LIDAR data for displaying changes on the Assateague Island National Seashore, Virginia. The analyzed results demonstrated that a further understanding to the study and comparison of the complex morphological changes that occur naturally or human-induced on barrier islands is required.
Not All Prehospital Time is Equal: Influence of Scene Time on Mortality
Brown, Joshua B.; Rosengart, Matthew R.; Forsythe, Raquel M.; Reynolds, Benjamin R.; Gestring, Mark L.; Hallinan, William M.; Peitzman, Andrew B.; Billiar, Timothy R.; Sperry, Jason L.
2016-01-01
Background Trauma is time-sensitive and minimizing prehospital (PH) time is appealing. However, most studies have not linked increasing PH time with worse outcomes, as raw PH times are highly variable. It is unclear whether specific PH time patterns affect outcomes. Our objective was to evaluate the association of PH time interval distribution with mortality. Methods Patients transported by EMS in the Pennsylvania trauma registry 2000-2013 with total prehospital time (TPT)≥20min were included. TPT was divided into three PH time intervals: response, scene, and transport time. The number of minutes in each PH time interval was divided by TPT to determine the relative proportion each interval contributed to TPT. A prolonged interval was defined as any one PH interval contributing ≥50% of TPT. Patients were classified by prolonged PH interval or no prolonged PH interval (all intervals<50% of TPT). Patients were matched for TPT and conditional logistic regression determined the association of mortality with PH time pattern, controlling for confounders. PH interventions were explored as potential mediators, and prehospital triage criteria used identify patients with time-sensitive injuries. Results There were 164,471 patients included. Patients with prolonged scene time had increased odds of mortality (OR 1.21; 95%CI 1.02–1.44, p=0.03). Prolonged response, transport, and no prolonged interval were not associated with mortality. When adjusting for mediators including extrication and PH intubation, prolonged scene time was no longer associated with mortality (OR 1.06; 0.90–1.25, p=0.50). Together these factors mediated 61% of the effect between prolonged scene time and mortality. Mortality remained associated with prolonged scene time in patients with hypotension, penetrating injury, and flail chest. Conclusions Prolonged scene time is associated with increased mortality. PH interventions partially mediate this association. Further study should evaluate whether these interventions drive increased mortality because they prolong scene time or by another mechanism, as reducing scene time may be a target for intervention. Level of Evidence IV, prognostic study PMID:26886000
Elsherif, Mohamed; Tawfick, Wael; Canning, Patrick; Hynes, Niamh; Sultan, Sherif
2018-04-01
Aim We aim to compare the outcome of diabetic patients with gangrenous toes who were managed initially either by digital amputation or by transmetatarsal amputation. The null hypothesis is that transmetatarsal amputation had less theatre trips and better healing. Materials and Methods A parallel observational comparative study of all diabetic patients who underwent either digital or transmetatarsal amputation in a tertiary referral center from 2002 through 2015. Comorbid conditions, subsequent amputations, hospital stay, and readmission were noted. Results A total of 223 patients underwent minor amputation during the study period, of which 147 patients were diabetic and 76 patients were non-diabetic. Seventy-seven patients had digital amputation and 70 transmetatarsal amputation in diabetic patients. Demographics were similar in both groups. The median time to major amputation was (400 ± IQR 1205 days) in the digital amputation group, compared to 690 ± IQR 891 days in the transmetatarsal amputation group ( P = 0.974). 29.9% of digital amputations and 15.7% of transmetatarsal amputations in diabetic patients, required minor amputations or revision procedures ( P = 0.04). Median length of hospital stay was (20 days, IQR 27) in the digital group and (17 days, IQR17) in the transmetatarsal amputation group ( P = 0.17). Need for re-admission was 48.1% in digital patients compared to 50% in transmetatarsal amputation patients ( P = 0.81). Quality of time spent without symptoms of disease or toxicity of treatment (Q-TWiST) was (315 days, IQR 45) in digital group and (346 days, IQR 48) in the transmetatarsal amputation patients ( P = 0.099). Conclusion Despite the lack of statistical significance, transmetatarsal amputation offered better outcome in the diabetic patients, with less re-intervention rate, shorter hospital stays, less theatre trips, and longer time without toxicity (TWiST).
Panek, Petr; Prochazka, Ivan
2007-09-01
This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.
An 11-bit and 39 ps resolution time-to-digital converter for ADPLL in digital television
NASA Astrophysics Data System (ADS)
Liu, Wei; (Ruth) Li, Wei; Ren, P.; Lin, C. L.; Zhang, Shengdong; Wang, Yangyuan
2010-04-01
We propose and demonstrate an 11-bit time-to-digital converter (TDC) for all-digital phase-locked loops (ADPLLs) in digital television. The proposed TDC converts the width of the input pulse into digital output with the tap space of the outputs of a free-running ring oscillator (FRO) being the conversion resolution. The FRO is in a structure of coiled cell array and the TDC core is symmetrical in the input structure. This leads to equally spaced taps in the reference clocks and thereby a high TDC conversion linearity. The TDC is fabricated in 0.13 μm CMOS process and the chip area is 0.025 mm2. The measurement results show that the TDC has a conversion resolution of 39 ps at 1.2 V power supply and a 4.5 ns dead time in the 11-bits output case. Both the differential non-linearity (DNL) and integral non-linearity (INL) are below 0.5 LSB. The power consumption of the whole circuit is 4.2 mW.
Warburton, W.K.
1999-02-16
A high speed, digitally based, signal processing system is disclosed which accepts a digitized input signal and detects the presence of step-like pulses in the this data stream, extracts filtered estimates of their amplitudes, inspects for pulse pileup, and records input pulse rates and system lifetime. The system has two parallel processing channels: a slow channel, which filters the data stream with a long time constant trapezoidal filter for good energy resolution; and a fast channel which filters the data stream with a short time constant trapezoidal filter, detects pulses, inspects for pileups, and captures peak values from the slow channel for good events. The presence of a simple digital interface allows the system to be easily integrated with a digital processor to produce accurate spectra at high count rates and allow all spectrometer functions to be fully automated. Because the method is digitally based, it allows pulses to be binned based on time related values, as well as on their amplitudes, if desired. 31 figs.
Mirror Numbers and Wigner's ``Unreasonable Effectiveness''
NASA Astrophysics Data System (ADS)
Berezin, Alexander
2006-04-01
Wigner's ``unreasonable effectiveness of mathematics in physics'' can be augmented by concept of mirror number (MN). It is defined as digital string infinite in both directions. Example is ()5141327182() where first 5 digits is Pi ``spelled'' backward (``mirrored'') and last 5 digits is the beginning of decimal exp1 string. Let MN be constructed from two different transcendental (or algebraically irrational) numbers, set of such MNs is Cantor-uncountable. Most MNs have contain any finite digital sequence repeated infinitely many times. In spirit of ``Contact'' (C.Sagan) each normal MN contains ``Library of Babel'' of all possible texts and patterns (J.L.Borges). Infinite at both ends, MN do not have any numerical values and, contrary to numbers written in positional systems, all digits in MNs have equal weight -- sort of ``numerological democracy''. In Pythagorean-Platonic models (space-time and physical world originating from pure numbers) idea of MN resolves paradox of ``beginning'' (or ``end'') of time. Because in MNs all digits have equal status, (quantum) randomness leads to more uniform and fully ergodic phase trajectories (cf. F.Dyson, Infinite in All Directions) .
Guy, Kristy K.
2015-01-01
This Data Series Report includes several open-ocean shorelines, back-island shorelines, back-island shoreline points, sand area polygons, and sand lines for Assateague Island that were extracted from natural-color orthoimagery (aerial photography) dated from April 12, 1989, to September 5, 2013. The images used were 0.3–2-meter (m)-resolution U.S. Geological Survey Digital Orthophoto Quarter Quads (DOQQ), U.S. Department of Agriculture National Agriculture Imagery Program (NAIP) images, and Virginia Geographic Information Network Virginia Base Map Program (VBMP) images courtesy of the Commonwealth of Virginia. The back-island shorelines were hand-digitized at the intersect of the apparent back-island shoreline and transects spaced at 20-m intervals. The open-ocean shorelines were hand-digitized at the approximate still water level, such as tide level, which was fit through the average position of waves and swash apparent on the beach. Hand-digitizing was done at a scale of approximately 1:2,000. The sand polygons were derived by using an image-processing unsupervised classification technique that separates images into classes. The classes were then visually categorized as either sand or not sand. Also included in this report are 20-m-spaced transect lines and the transect base lines.
An object-oriented simulator for 3D digital breast tomosynthesis imaging system.
Seyyedi, Saeed; Cengiz, Kubra; Kamasak, Mustafa; Yildirim, Isa
2013-01-01
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values.