Sample records for time interval measuring

  1. Time interval measurement device based on surface acoustic wave filter excitation, providing 1 ps precision and stability.

    PubMed

    Panek, Petr; Prochazka, Ivan

    2007-09-01

    This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.

  2. Method of high precision interval measurement in pulse laser ranging system

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong

    2013-09-01

    Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.

  3. a New Approach for Accuracy Improvement of Pulsed LIDAR Remote Sensing Data

    NASA Astrophysics Data System (ADS)

    Zhou, G.; Huang, W.; Zhou, X.; He, C.; Li, X.; Huang, Y.; Zhang, L.

    2018-05-01

    In remote sensing applications, the accuracy of time interval measurement is one of the most important parameters that affect the quality of pulsed lidar data. The traditional time interval measurement technique has the disadvantages of low measurement accuracy, complicated circuit structure and large error. A high-precision time interval data cannot be obtained in these traditional methods. In order to obtain higher quality of remote sensing cloud images based on the time interval measurement, a higher accuracy time interval measurement method is proposed. The method is based on charging the capacitance and sampling the change of capacitor voltage at the same time. Firstly, the approximate model of the capacitance voltage curve in the time of flight of pulse is fitted based on the sampled data. Then, the whole charging time is obtained with the fitting function. In this method, only a high-speed A/D sampler and capacitor are required in a single receiving channel, and the collected data is processed directly in the main control unit. The experimental results show that the proposed method can get error less than 3 ps. Compared with other methods, the proposed method improves the time interval accuracy by at least 20 %.

  4. TIME-INTERVAL MEASURING DEVICE

    DOEpatents

    Gross, J.E.

    1958-04-15

    An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.

  5. [Study on the acquiring data time and intervals for measuring performance of air cleaner on formaldehyde].

    PubMed

    Tang, Zhigang; Wang, Guifang; Xu, Dongqun; Han, Keqin; Li, Yunpu; Zhang, Aijun; Dong, Xiaoyan

    2004-09-01

    The measuring time and measuring intervals to evaluate different type of air cleaner performance to remove formaldehyde were provided. The natural decay measurement and formaldehyde removal measurement were conducted in 1.5 m3 and 30 m3 test chamber. The natural decay rate was determined by acquiring formaldehyde concentration data at 15 minute intervals for 2.5 hours. The measured decay rate was determined by acquiring formaldehyde concentration data at 5 minute intervals for 1.2 hours. When the wind power of air cleaner is smaller than 30 m3/h or measuring performance of no wind power air clearing product, the 1.5 m3 test chamber can be used. Both the natural decay rate and the measured decay rate are determined by acquiring formaldehyde concentration data at 8 minute intervals for 64 minutes. There were different measuring time and measuring intervals to evaluate different type of air cleaner performance to remove formaldehyde.

  6. Longitudinal change in dysarthria associated with Friedreich ataxia: a potential clinical endpoint.

    PubMed

    Rosen, Kristin M; Folker, Joanne E; Vogel, Adam P; Corben, Louise A; Murdoch, Bruce E; Delatycki, Martin B

    2012-11-01

    CNS functions that show change across short periods of time are particularly useful clinical endpoints for Friedreich ataxia. This study determined whether there is measurable acoustical change in the dysarthria associated with Friedreich ataxia across yearly intervals. A total of 29 participants diagnosed with Friedreich ataxia were recorded across 4 years at yearly intervals. A repeated measures ANOVA was used to determine which acoustic measures differed across time, and pairwise t tests were used to assess the consistency of the change across the time intervals. The relationship between the identified measures with perceptual severity was assessed with stepwise regression. Significant longitudinal change was observed with four measures that relate to the utterance duration and spectral changes in utterances. The spectral measures consistently detected change across time intervals of two or more years. The four measures combined moderately predicted perceptual severity. Together, the results implicate longitudinal change in speaking rate and utterance duration. Changes in speech associated with Friedreich ataxia can be measured across intervals of 2 years and therefore show rich potential for monitoring disease progression and therapy outcomes.

  7. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    PubMed

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  8. Versatile all-digital time interval measuring system

    NASA Astrophysics Data System (ADS)

    Vyhlidal, David; Cech, Miroslav

    2011-06-01

    This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.

  9. Measuring Time on the PET and Other Microcomputers

    ERIC Educational Resources Information Center

    Tesler, Larry

    1978-01-01

    The operation of the microcomputer requires one or more clocks or timers to measure intervals of different magnitudes. Methods are discussed for measuring time intervals on PET in hours, minutes, seconds, microseconds, miscellaneous units, and timing events on external devices. Directions are added for BASIC program applications of timing…

  10. Systolic time interval data acquisition system. Specialized cardiovascular studies

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1976-01-01

    The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

  11. The interval between prothrombin time tests and the quality of oral anticoagulants treatment in patients with chronic atrial fibrillation.

    PubMed

    Shalev, Varda; Rogowski, Ori; Shimron, Orit; Sheinberg, Bracha; Shapira, Itzhak; Seligsohn, Uri; Berliner, Shlomo; Misgav, Mudi

    2007-01-01

    The incidence of stroke in patients with atrial fibrillation (AF) can be significantly reduced with warfarin therapy especially if optimally controlled. To evaluate the effect of the interval between consecutive prothrombin time measurements on the time in therapeutic range (INR 2-3) in a cohort of patients with AF on chronic warfarin treatment in the community. All INR measurements available from a relatively large cohort of patients with chronic AF were reviewed and the mean interval between consecutive INR tests of each patient was correlated with the time in therapeutic range (TTR). Altogether 251,916 INR measurements performed in 4408 patients over a period of seven years were reviewed. Sixty percent of patients had their INR measured on average every 2 to 3 weeks and most others were followed at intervals of 4 weeks or longer. A small proportion (3.6%) had their INR measured on average every week. A significant decline in the time in therapeutic range was observed as the intervals between tests increased. At one to three weeks interval the TTR was 48%, at 4 weeks interval 45% and at 5 weeks 41% (P<0.0005). A five percent increment in TTR was observed if more tests were performed at multiplications of exactly 7 days (43% vs 48% P<0.0001). A better control with an increase in the TTR was observed in patients with atrial fibrillation if prothrombin time tests are performed at regular intervals of no longer than 3 weeks.

  12. Interval stability for complex systems

    NASA Astrophysics Data System (ADS)

    Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.

    2018-04-01

    Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.

  13. Validity and Generalizability of Measuring Student Engaged Time in Physical Education.

    ERIC Educational Resources Information Center

    Silverman, Stephen; Zotos, Connee

    The validity of interval and time sampling methods of measuring student engaged time was investigated in a study estimating the actual time students spent engaged in relevant motor performance in physical education classes. Two versions of the interval Academic Learning Time in Physical Education (ALT-PE) instrument and an equivalent time sampling…

  14. System implications of the ambulance arrival-to-patient contact interval on response interval compliance.

    PubMed

    Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A

    1994-01-01

    In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.

  15. Working times of elastomeric impression materials determined by dimensional accuracy.

    PubMed

    Tan, E; Chai, J; Wozniak, W T

    1996-01-01

    The working times of five poly(vinyl siloxane) impression materials were estimated by evaluating the dimensional accuracy of stone dies of impressions of a standard model made at successive time intervals. The stainless steel standard model was represented by two abutments having known distances between landmarks in three dimensions. Three dimensions in the x-, y-, and z-axes of the stone dies were measured with a traveling microscope. A time interval was rejected as being within the working time if the percentage change of the resultant dies, in any dimension, was statistically different from those measured from stone dies from previous time intervals. The absolute dimensions of those dies from the rejected time interval also must have exceeded all those from previous time intervals. Results showed that the working times estimated with this method generally were about 30 seconds longer than those recommended by the manufacturers.

  16. Time-measurement-regulating peptide PIN may alter a timer conformation of Time Interval Measuring Enzyme (TIME).

    PubMed

    Ti, Xiaonan; Tani, Naoki; Isobe, Minoru; Kai, Hidenori

    2006-05-01

    The TIME (Time Interval Measuring Enzyme) ATPase measures time intervals in accordance with diapause development, which indispensably requires cold for resumption of embryonic development in the silkworm (Bombyx mori). The PIN (Peptidyl Inhibitory Needle) peptide regulates the time measurement function of TIME. In the present study we investigated the interaction between TIME and PIN in order to address the mechanism of diapause development. When TIME was isolated from eggs later than 12 days after oviposition, transient bursts of ATPase activity occurred 18h after isolation of TIME, and the younger the eggs and pupal ovaries from which TIME was isolated, the earlier the bursts of ATPase activity appeared. However, no interval-timer activation of ATPase occurred in ovaries earlier than 6 days after pupation. Similar patterns of ATPase activity occurred in test tubes after mixing TIME with PIN. The shorter the time PIN was mixed with TIME, the earlier the ATPase activity appeared. The timer may be built into the protein conformation of TIME, and PIN (which is present in ovaries beginning 6 days after pupation) appears able to alter this timer conformation through pupal stages to laid eggs. We discuss the possible mechanism of diapause development in relation to the timer mechanism of TIME.

  17. Interval sampling methods and measurement error: a computer simulation.

    PubMed

    Wirth, Oliver; Slaven, James; Taylor, Matthew A

    2014-01-01

    A simulation study was conducted to provide a more thorough account of measurement error associated with interval sampling methods. A computer program simulated the application of momentary time sampling, partial-interval recording, and whole-interval recording methods on target events randomly distributed across an observation period. The simulation yielded measures of error for multiple combinations of observation period, interval duration, event duration, and cumulative event duration. The simulations were conducted up to 100 times to yield measures of error variability. Although the present simulation confirmed some previously reported characteristics of interval sampling methods, it also revealed many new findings that pertain to each method's inherent strengths and weaknesses. The analysis and resulting error tables can help guide the selection of the most appropriate sampling method for observation-based behavioral assessments. © Society for the Experimental Analysis of Behavior.

  18. Department of Defense Precise Time and Time Interval program improvement plan

    NASA Technical Reports Server (NTRS)

    Bowser, J. R.

    1981-01-01

    The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.

  19. Relationship between cutoff frequency and accuracy in time-interval photon statistics applied to oscillating signals

    NASA Astrophysics Data System (ADS)

    Rebolledo, M. A.; Martinez-Betorz, J. A.

    1989-04-01

    In this paper the accuracy in the determination of the period of an oscillating signal, when obtained from the photon statistics time-interval probability, is studied as a function of the precision (the inverse of the cutoff frequency of the photon counting system) with which time intervals are measured. The results are obtained by means of an experiment with a square-wave signal, where the Fourier or square-wave transforms of the time-interval probability are measured. It is found that for values of the frequency of the signal near the cutoff frequency the errors in the period are small.

  20. Analysis of single ion channel data incorporating time-interval omission and sampling

    PubMed Central

    The, Yu-Kai; Timmer, Jens

    2005-01-01

    Hidden Markov models are widely used to describe single channel currents from patch-clamp experiments. The inevitable anti-aliasing filter limits the time resolution of the measurements and therefore the standard hidden Markov model is not adequate anymore. The notion of time-interval omission has been introduced where brief events are not detected. The developed, exact solutions to this problem do not take into account that the measured intervals are limited by the sampling time. In this case the dead-time that specifies the minimal detectable interval length is not defined unambiguously. We show that a wrong choice of the dead-time leads to considerably biased estimates and present the appropriate equations to describe sampled data. PMID:16849220

  1. Digital computing cardiotachometer

    NASA Technical Reports Server (NTRS)

    Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)

    1973-01-01

    A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.

  2. Measuring the EMS patient access time interval and the impact of responding to high-rise buildings.

    PubMed

    Morrison, Laurie J; Angelini, Mark P; Vermeulen, Marian J; Schwartz, Brian

    2005-01-01

    To measure the patient access time interval and characterize its contribution to the total emergency medical services (EMS) response time interval; to compare the patient access time intervals for patients located three or more floors above ground with those less than three floors above or below ground, and specifically in the apartment subgroup; and to identify barriers that significantly impede EMS access to patients in high-rise apartments. An observational study of all patients treated by an emergency medical technician paramedics (EMT-P) crew was conducted using a trained independent observer to collect time intervals and identify potential barriers to access. Of 118 observed calls, 25 (21%) originated from patients three or more floors above ground. The overall median and 90th percentile (95% confidence interval) patient access time intervals were 1.61 (1.27, 1.91) and 3.47 (3.08, 4.05) minutes, respectively. The median interval was 2.73 (2.22, 3.03) minutes among calls from patients located three or more stories above ground compared with 1.25 (1.07, 1.55) minutes among those at lower levels. The patient access time interval represented 23.5% of the total EMS response time interval among calls originating less than three floors above or below ground and 32.2% of those located three or more stories above ground. The most frequently encountered barriers to access included security code entry requirements, lack of directional signs, and inability to fit the stretcher into the elevator. The patient access time interval is significantly long and represents a substantial component of the total EMS response time interval, especially among ambulance calls originating three or more floors above ground. A number of barriers appear to contribute to delayed paramedic access.

  3. The Time Is Up: Compression of Visual Time Interval Estimations of Bimodal Aperiodic Patterns

    PubMed Central

    Duarte, Fabiola; Lemus, Luis

    2017-01-01

    The ability to estimate time intervals subserves many of our behaviors and perceptual experiences. However, it is not clear how aperiodic (AP) stimuli affect our perception of time intervals across sensory modalities. To address this question, we evaluated the human capacity to discriminate between two acoustic (A), visual (V) or audiovisual (AV) time intervals of trains of scattered pulses. We first measured the periodicity of those stimuli and then sought for correlations with the accuracy and reaction times (RTs) of the subjects. We found that, for all time intervals tested in our experiment, the visual system consistently perceived AP stimuli as being shorter than the periodic (P) ones. In contrast, such a compression phenomenon was not apparent during auditory trials. Our conclusions are: first, the subjects exposed to P stimuli are more likely to measure their durations accurately. Second, perceptual time compression occurs for AP visual stimuli. Lastly, AV discriminations are determined by A dominance rather than by AV enhancement. PMID:28848406

  4. Evaluation of the electromechanical properties of the cardiovascular system after prolonged weightlessness

    NASA Technical Reports Server (NTRS)

    Bergman, S. A., Jr.; Johnson, R. L.; Hoffler, G. W.

    1977-01-01

    Devices and techniques for measuring and analyzing systolic time intervals and quantitative phonocardiograms were initiated during Apollo 17. The data show that the systolic time interval from Apollo 17 crewmen remained elevated longer postflight than the response criteria of heart rate, blood pressure, and percent change in leg volume all of which had returned to preflight levels by the second day postflight. Although the systolic time interval values were only slightly outside the preflight fiducial limits, this finding suggested that: the analysis of systolic time intervals may help to identify the mechanisms of postflight orthostatic intolerance by virtue of measuring ventricular function more directly and, the noninvasive technique may prove useful in determining the extent and duration of cardiovascular instability after long duration space flight. The systolic time intervals obtained on the Apollo 17 crewmen during lower body negative pressure were similar to those noted in patients with significant heart disease.

  5. Online evolution reconstruction from a single measurement record with random time intervals for quantum communication

    NASA Astrophysics Data System (ADS)

    Zhou, Hua; Su, Yang; Wang, Rong; Zhu, Yong; Shen, Huiping; Pu, Tao; Wu, Chuanxin; Zhao, Jiyong; Zhang, Baofu; Xu, Zhiyong

    2017-10-01

    Online reconstruction of a time-variant quantum state from the encoding/decoding results of quantum communication is addressed by developing a method of evolution reconstruction from a single measurement record with random time intervals. A time-variant two-dimensional state is reconstructed on the basis of recovering its expectation value functions of three nonorthogonal projectors from a random single measurement record, which is composed from the discarded qubits of the six-state protocol. The simulated results prove that our method is robust to typical metro quantum channels. Our work extends the Fourier-based method of evolution reconstruction from the version for a regular single measurement record with equal time intervals to a unified one, which can be applied to arbitrary single measurement records. The proposed protocol of evolution reconstruction runs concurrently with the one of quantum communication, which can facilitate the online quantum tomography.

  6. Synopsis of timing measurement techniques used in telecommunications

    NASA Technical Reports Server (NTRS)

    Zampetti, George

    1993-01-01

    Historically, Maximum Time Interval Error (MTIE) and Maximum Relative Time Interval Error (MRTIE) have been the main measurement techniques used to characterize timing performance in telecommunications networks. Recently, a new measurement technique, Time Variance (TVAR) has gained acceptance in the North American (ANSI) standards body. TVAR was developed in concurrence with NIST to address certain inadequacies in the MTIE approach. The advantages and disadvantages of each of these approaches are described. Real measurement examples are presented to illustrate the critical issues in actual telecommunication applications. Finally, a new MTIE measurement is proposed (ZTIE) that complements TVAR. Together, TVAR and ZTIE provide a very good characterization of network timing.

  7. Picosecond-precision multichannel autonomous time and frequency counter

    NASA Astrophysics Data System (ADS)

    Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  8. Picosecond-precision multichannel autonomous time and frequency counter.

    PubMed

    Szplet, R; Kwiatkowski, P; Różyc, K; Jachna, Z; Sondej, T

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 10 6 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  9. MEASUREMENT OF TIME INTERVALS FOR TIME CORRELATED RADIOACTIVE DECAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindeman, H.; Mornel, E.; Galil, U.

    1960-11-01

    The distribution of time intervals between successive counts was measured for radioactive decay in the thorium series. The measurements showed that the classical Marsden-Barratt law does not apply to this case of timecorrelated decay. They appeared, however, to be in agreement with the theory of Lindeman-Rosen, taking into account the fact that the counter receives only the radiation emitted in a solid angle near to 2 pi . (auth)

  10. Proceedings of the Fourth Precise Time and Time Interval Planning Meeting

    NASA Technical Reports Server (NTRS)

    Acrivos, H. N. (Compiler); Wardrip, S. C. (Compiler)

    1972-01-01

    The proceedings of a conference on Precise Time and Time Interval Planning are presented. The subjects discussed include the following: (1) satellite timing techniques, precision frequency sources, and very long baseline interferometry, (2) frequency stabilities and communications, and (3) very low frequency and ultrahigh frequency propagation and use. Emphasis is placed on the accuracy of time discrimination obtained with time measuring equipment and specific applications of time measurement to military operations and civilian research projects.

  11. High resolution data acquisition

    DOEpatents

    Thornton, G.W.; Fuller, K.R.

    1993-04-06

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  12. High resolution data acquisition

    DOEpatents

    Thornton, Glenn W.; Fuller, Kenneth R.

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  13. Use of precision time and time interval (PTTI)

    NASA Technical Reports Server (NTRS)

    Taylor, J. D.

    1974-01-01

    A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.

  14. Intact interval timing in circadian CLOCK mutants.

    PubMed

    Cordes, Sara; Gallistel, C R

    2008-08-28

    While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval-timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/- and -/- mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing.

  15. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    PubMed

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (p<0.001). Fetal heart rate decreased as gestation progressed (p<0.001). Thus, the AV intervals increased with the age of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  16. Measuring Safety Performance: A Comparison of Whole, Partial, and Momentary Time-Sampling Recording Methods

    ERIC Educational Resources Information Center

    Alvero, Alicia M.; Struss, Kristen; Rappaport, Eva

    2008-01-01

    Partial-interval (PIR), whole-interval (WIR), and momentary time sampling (MTS) estimates were compared against continuous measures of safety performance for three postural behaviors: feet, back, and shoulder position. Twenty-five samples of safety performance across five undergraduate students were scored using a second-by-second continuous…

  17. Ratio-based lengths of intervals to improve fuzzy time series forecasting.

    PubMed

    Huarng, Kunhuang; Yu, Tiffany Hui-Kuang

    2006-04-01

    The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.

  18. Interval timing in genetically modified mice: a simple paradigm

    PubMed Central

    Balci, F.; Papachristos, E. B.; Gallistel, C. R.; Brunner, D.; Gibson, J.; Shumyatsky, G. P.

    2009-01-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using D-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently. PMID:17696995

  19. Interval timing in genetically modified mice: a simple paradigm.

    PubMed

    Balci, F; Papachristos, E B; Gallistel, C R; Brunner, D; Gibson, J; Shumyatsky, G P

    2008-04-01

    We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using d-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently.

  20. Linear time-dependent reference intervals where there is measurement error in the time variable-a parametric approach.

    PubMed

    Gillard, Jonathan

    2015-12-01

    This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.

  1. Intact Interval Timing in Circadian CLOCK Mutants

    PubMed Central

    Cordes, Sara; Gallistel, C. R.

    2008-01-01

    While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/− and −/− mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing. PMID:18602902

  2. Measurement of Trained Speech Patterns in Stuttering: Interjudge and Intrajudge Agreement of Experts by Means of Modified Time-Interval Analysis

    ERIC Educational Resources Information Center

    Alpermann, Anke; Huber, Walter; Natke, Ulrich; Willmes, Klaus

    2010-01-01

    Improved fluency after stuttering therapy is usually measured by the percentage of stuttered syllables. However, outcome studies rarely evaluate the use of trained speech patterns that speakers use to manage stuttering. This study investigated whether the modified time interval analysis can distinguish between trained speech patterns, fluent…

  3. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  4. Event- and interval-based measurement of stuttering: a review.

    PubMed

    Valente, Ana Rita S; Jesus, Luis M T; Hall, Andreia; Leahy, Margaret

    2015-01-01

    Event- and interval-based measurements are two different ways of computing frequency of stuttering. Interval-based methodology emerged as an alternative measure to overcome problems associated with reproducibility in the event-based methodology. No review has been made to study the effect of methodological factors in interval-based absolute reliability data or to compute the agreement between the two methodologies in terms of inter-judge, intra-judge and accuracy (i.e., correspondence between raters' scores and an established criterion). To provide a review related to reproducibility of event-based and time-interval measurement, and to verify the effect of methodological factors (training, experience, interval duration, sample presentation order and judgment conditions) on agreement of time-interval measurement; in addition, to determine if it is possible to quantify the agreement between the two methodologies The first two authors searched for articles on ERIC, MEDLINE, PubMed, B-on, CENTRAL and Dissertation Abstracts during January-February 2013 and retrieved 495 articles. Forty-eight articles were selected for review. Content tables were constructed with the main findings. Articles related to event-based measurements revealed values of inter- and intra-judge greater than 0.70 and agreement percentages beyond 80%. The articles related to time-interval measures revealed that, in general, judges with more experience with stuttering presented significantly higher levels of intra- and inter-judge agreement. Inter- and intra-judge values were beyond the references for high reproducibility values for both methodologies. Accuracy (regarding the closeness of raters' judgements with an established criterion), intra- and inter-judge agreement were higher for trained groups when compared with non-trained groups. Sample presentation order and audio/video conditions did not result in differences in inter- or intra-judge results. A duration of 5 s for an interval appears to be an acceptable agreement. Explanation for high reproducibility values as well as parameter choice to report those data are discussed. Both interval- and event-based methodologies used trained or experienced judges for inter- and intra-judge determination and data were beyond the references for good reproducibility values. Inter- and intra-judge values were reported in different metric scales among event- and interval-based methods studies, making it unfeasible to quantify the agreement between the two methods. © 2014 Royal College of Speech and Language Therapists.

  5. A novel handheld device for use in remote patient monitoring of heart failure patients--design and preliminary validation on healthy subjects.

    PubMed

    Pollonini, Luca; Rajan, Nithin O; Xu, Shuai; Madala, Sridhar; Dacso, Clifford C

    2012-04-01

    Remote patient monitoring (RPM) holds great promise for reducing the burden of congestive heart failure (CHF). Improved sensor technology and effective predictive algorithms can anticipate sudden decompensation events. Enhanced telemonitoring systems would promote patient independence and facilitate communication between patients and their physicians. We report the development of a novel hand-held device, called Blue Box, capable of collecting and wirelessly transmitting key cardiac parameters derived from three integrated biosensors: 2 lead electrocardiogram (ECG), photoplethysmography and bioelectrical impedance (bioimpedance). Blue Box measurements include time intervals between consecutive ECG R-waves (RR interval), time duration of the ECG complex formed by the Q, R and S waves (QRS duration), bioimpedance, heart rate and systolic time intervals. In this study, we recruited 24 healthy subjects to collect several parameters measured by Blue Box and assess their value in correlating with cardiac output measured with Echo-Doppler. Linear correlation between the heart rate measured with Blue Box and cardiac output from Echo-Doppler had a group average correlation coefficient of 0.80. We found that systolic time intervals did not improve the model significantly. However, STIs did inversely correlate with increasing workloads.

  6. Determination of heart rate variability with an electronic stethoscope.

    PubMed

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  7. Time Components of the Left Ventricle.

    ERIC Educational Resources Information Center

    Franks, B. Don

    The purpose of this study was to examine the relationship of the time components of the left ventricle. Since one of the ways to investigate cardiac function is to analyze the time intervals between particular events of the cardiac cycle, various time intervals of systole and diastole of the left ventricle were measured from simultaneous…

  8. Measurement of trained speech patterns in stuttering: interjudge and intrajudge agreement of experts by means of modified time-interval analysis.

    PubMed

    Alpermann, Anke; Huber, Walter; Natke, Ulrich; Willmes, Klaus

    2010-09-01

    Improved fluency after stuttering therapy is usually measured by the percentage of stuttered syllables. However, outcome studies rarely evaluate the use of trained speech patterns that speakers use to manage stuttering. This study investigated whether the modified time interval analysis can distinguish between trained speech patterns, fluent speech, and stuttered speech. Seventeen German experts on stuttering judged a speech sample on two occasions. Speakers of the sample were stuttering adults, who were not undergoing therapy, as well as participants in a fluency shaping and a stuttering modification therapy. Results showed satisfactory inter-judge and intra-judge agreement above 80%. Intervals with trained speech patterns were identified as consistently as stuttered and fluent intervals. We discuss limitations of the study, as well as implications of our findings for the development of training for identification of trained speech patterns and future outcome studies. The reader will be able to (a) explain different methods to measure the use of trained speech patterns, (b) evaluate whether German experts are able to discriminate intervals with trained speech patterns reliably from fluent and stuttered intervals and (c) describe how the measurement of trained speech patterns can contribute to outcome studies.

  9. The time course of corticospinal excitability during a simple reaction time task.

    PubMed

    Kennefick, Michael; Maslovat, Dana; Carlsen, Anthony N

    2014-01-01

    The production of movement in a simple reaction time task can be separated into two time periods: the foreperiod, which is thought to include preparatory processes, and the reaction time interval, which includes initiation processes. To better understand these processes, transcranial magnetic stimulation has been used to probe corticospinal excitability at various time points during response preparation and initiation. Previous research has shown that excitability decreases prior to the "go" stimulus and increases following the "go"; however these two time frames have been examined independently. The purpose of this study was to measure changes in CE during both the foreperiod and reaction time interval in a single experiment, relative to a resting baseline level. Participants performed a button press movement in a simple reaction time task and excitability was measured during rest, the foreperiod, and the reaction time interval. Results indicated that during the foreperiod, excitability levels quickly increased from baseline with the presentation of the warning signal, followed by a period of stable excitability leading up to the "go" signal, and finally a rapid increase in excitability during the reaction time interval. This excitability time course is consistent with neural activation models that describe movement preparation and response initiation.

  10. Summary of extensometric measurements in El Paso, Texas

    USGS Publications Warehouse

    Heywood, Charles E.

    2003-01-01

    Two counter-weighted-pipe borehole extensometers were installed on the left bank of the Rio Grande between El Paso, Texas, and Ciudad Juarez, Chihuahua, Mexico, in 1992. A shallow extensometer measures vertical compaction in the 6- to 100-meter aquifer-system depth interval. A deep extensometer measures vertical compaction in the 6- to 305-meter aquifer-system depth interval. Both extensometers are referenced to the same surface datum, which allows time-series differencing to determine vertical compaction in the depth interval between 100 and 305 meters. From April 2, 1993, through June 13, 2002, 1.6 centimeters of compaction occurred in the 6-to 305-m depth interval. Until February 1999, most aquifer-system compaction occurred in the deeper aquifer-system interval between 100 and 305 meters, from which ground water was extracted. After that time, compaction in the shallow interval from 6 to 100 meters was predominant and attained a maximum of 7.6 millimeters by June 13, 2002. Minor residual compaction is expected to continue; continued maintenance of the El Paso extensometers would document this process.

  11. Evaluation of the Trail Making Test and interval timing as measures of cognition in healthy adults: comparisons by age, education, and gender.

    PubMed

    Płotek, Włodzimierz; Łyskawa, Wojciech; Kluzik, Anna; Grześkowiak, Małgorzata; Podlewski, Roland; Żaba, Zbigniew; Drobnik, Leon

    2014-02-03

    Human cognitive functioning can be assessed using different methods of testing. Age, level of education, and gender may influence the results of cognitive tests. The well-known Trail Making Test (TMT), which is often used to measure the frontal lobe function, and the experimental test of Interval Timing (IT) were compared. The methods used in IT included reproduction of auditory and visual stimuli, with the subsequent production of the time intervals of 1-, 2-, 5-, and 7-seconds durations with no pattern. Subjects included 64 healthy adult volunteers aged 18-63 (33 women, 31 men). Comparisons were made based on age, education, and gender. TMT was performed quickly and was influenced by age, education, and gender. All reproduced visual and produced intervals were shortened and the reproduction of auditory stimuli was more complex. Age, education, and gender have more pronounced impact on the cognitive test than on the interval timing test. The reproduction of the short auditory stimuli was more accurate in comparison to other modalities used in the IT test. The interval timing, when compared to the TMT, offers an interesting possibility of testing. Further studies are necessary to confirm the initial observation.

  12. Deficits in Interval Timing Measured by the Dual-Task Paradigm among Children and Adolescents with Attention-Deficit/Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Hwang, Shoou-Lian; Gau, Susan Shur-Fen; Hsu, Wen-Yau; Wu, Yu-Yu

    2010-01-01

    Background: The underlying mechanism of time perception deficit in long time intervals in attention-deficit/hyperactivity disorder (ADHD) is still unclear. This study used the time reproduction dual task to explore the role of the attentional resource in time perception deficits among children and adolescents with ADHD. Methods: Participants…

  13. A new time calibration method for switched-capacitor-array-based waveform samplers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, H.; Chen, C. -T.; Eclov, N.

    2014-08-24

    Here we have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibrationmore » is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. Ultimately, the new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.« less

  14. A new time calibration method for switched-capacitor-array-based waveform samplers

    NASA Astrophysics Data System (ADS)

    Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Moses, W.; Choong, W.-S.; Kao, C.-M.

    2014-12-01

    We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be 2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

  15. A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers.

    PubMed

    Kim, H; Chen, C-T; Eclov, N; Ronzhin, A; Murat, P; Ramberg, E; Los, S; Moses, W; Choong, W-S; Kao, C-M

    2014-12-11

    We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration.

  16. A New Time Calibration Method for Switched-capacitor-array-based Waveform Samplers

    PubMed Central

    Kim, H.; Chen, C.-T.; Eclov, N.; Ronzhin, A.; Murat, P.; Ramberg, E.; Los, S.; Moses, W.; Choong, W.-S.; Kao, C.-M.

    2014-01-01

    We have developed a new time calibration method for the DRS4 waveform sampler that enables us to precisely measure the non-uniform sampling interval inherent in the switched-capacitor cells of the DRS4. The method uses the proportionality between the differential amplitude and sampling interval of adjacent switched-capacitor cells responding to a sawtooth-shape pulse. In the experiment, a sawtooth-shape pulse with a 40 ns period generated by a Tektronix AWG7102 is fed to a DRS4 evaluation board for calibrating the sampling intervals of all 1024 cells individually. The electronic time resolution of the DRS4 evaluation board with the new time calibration is measured to be ~2.4 ps RMS by using two simultaneous Gaussian pulses with 2.35 ns full-width at half-maximum and applying a Gaussian fit. The time resolution dependencies on the time difference with the new time calibration are measured and compared to results obtained by another method. The new method could be applicable for other switched-capacitor-array technology-based waveform samplers for precise time calibration. PMID:25506113

  17. Modulation of human time processing by subthalamic deep brain stimulation.

    PubMed

    Wojtecki, Lars; Elben, Saskia; Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons

    2011-01-01

    Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥ 130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥ 130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds.

  18. Modulation of Human Time Processing by Subthalamic Deep Brain Stimulation

    PubMed Central

    Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons

    2011-01-01

    Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds. PMID:21931767

  19. Quantification of transuranic elements by time interval correlation spectroscopy of the detected neutrons

    PubMed

    Baeten; Bruggeman; Paepen; Carchon

    2000-03-01

    The non-destructive quantification of transuranic elements in nuclear waste management or in safeguards verifications is commonly performed by passive neutron assay techniques. To minimise the number of unknown sample-dependent parameters, Neutron Multiplicity Counting (NMC) is applied. We developed a new NMC-technique, called Time Interval Correlation Spectroscopy (TICS), which is based on the measurement of Rossi-alpha time interval distributions. Compared to other NMC-techniques, TICS offers several advantages.

  20. Ultrasonic sensor and method of use

    DOEpatents

    Condreva, Kenneth J.

    2001-01-01

    An ultrasonic sensor system and method of use for measuring transit time though a liquid sample, using one ultrasonic transducer coupled to a precision time interval counter. The timing circuit captures changes in transit time, representing small changes in the velocity of sound transmitted, over necessarily small time intervals (nanoseconds) and uses the transit time changes to identify the presence of non-conforming constituents in the sample.

  1. Reaction time in pilots during intervals of high sustained g.

    PubMed

    Truszczynski, Olaf; Lewkowicz, Rafal; Wojtkowiak, Mieczyslaw; Biernacki, Marcin P

    2014-11-01

    An important problem for pilots is visual disturbances occurring under +Gz acceleration. Assessment of the degree of intensification of these disturbances is generally accepted as the acceleration tolerance level (ATL) criterion determined in human centrifuges. The aim of this research was to evaluate the visual-motor responses of pilots during rapidly increasing acceleration contained in cyclic intervals of +6 Gz to the maximum ATL. The study involved 40 male pilots ages 32-41 yr. The task was a quick and faultless response to the light stimuli presented on a light bar during exposure to acceleration until reaching the ATL. Simple response time (SRT) measurements were performed using a visual-motor analysis system throughout the exposures which allowed assessment of a pilot's ATL. There were 29 pilots who tolerated the initial phase of interval acceleration and achieved +6 Gz, completing the test at ATL. Relative to the control measurements, the obtained results indicate a significant effect of the applied acceleration on response time. SRT during +6 Gz exposure was not significantly longer compared with the reaction time between each of the intervals. SRT and erroneous reactions indicated no statistically significant differences between the "lower" and "higher" ATL groups. SRT measurements over the +6-Gz exposure intervals did not vary between "lower" and "higher" ATL groups and, therefore, are not useful in predicting pilot performance. The gradual exposure to the maximum value of +6 Gz with exposure to the first three intervals on the +6-Gz plateau effectively differentiated pilots.

  2. Phylogenetic diversity measures based on Hill numbers.

    PubMed

    Chao, Anne; Chiu, Chun-Huo; Jost, Lou

    2010-11-27

    We propose a parametric class of phylogenetic diversity (PD) measures that are sensitive to both species abundance and species taxonomic or phylogenetic distances. This work extends the conventional parametric species-neutral approach (based on 'effective number of species' or Hill numbers) to take into account species relatedness, and also generalizes the traditional phylogenetic approach (based on 'total phylogenetic length') to incorporate species abundances. The proposed measure quantifies 'the mean effective number of species' over any time interval of interest, or the 'effective number of maximally distinct lineages' over that time interval. The product of the measure and the interval length quantifies the 'branch diversity' of the phylogenetic tree during that interval. The new measures generalize and unify many existing measures and lead to a natural definition of taxonomic diversity as a special case. The replication principle (or doubling property), an important requirement for species-neutral diversity, is generalized to PD. The widely used Rao's quadratic entropy and the phylogenetic entropy do not satisfy this essential property, but a simple transformation converts each to our measures, which do satisfy the property. The proposed approach is applied to forest data for interpreting the effects of thinning.

  3. Cardiac interbeat interval dynamics from childhood to senescence : comparison of conventional and new measures based on fractals and chaos theory

    NASA Technical Reports Server (NTRS)

    Pikkujamsa, S. M.; Makikallio, T. H.; Sourander, L. B.; Raiha, I. J.; Puukka, P.; Skytta, J.; Peng, C. K.; Goldberger, A. L.; Huikuri, H. V.

    1999-01-01

    BACKGROUND: New methods of R-R interval variability based on fractal scaling and nonlinear dynamics ("chaos theory") may give new insights into heart rate dynamics. The aims of this study were to (1) systematically characterize and quantify the effects of aging from early childhood to advanced age on 24-hour heart rate dynamics in healthy subjects; (2) compare age-related changes in conventional time- and frequency-domain measures with changes in newly derived measures based on fractal scaling and complexity (chaos) theory; and (3) further test the hypothesis that there is loss of complexity and altered fractal scaling of heart rate dynamics with advanced age. METHODS AND RESULTS: The relationship between age and cardiac interbeat (R-R) interval dynamics from childhood to senescence was studied in 114 healthy subjects (age range, 1 to 82 years) by measurement of the slope, beta, of the power-law regression line (log power-log frequency) of R-R interval variability (10(-4) to 10(-2) Hz), approximate entropy (ApEn), short-term (alpha(1)) and intermediate-term (alpha(2)) fractal scaling exponents obtained by detrended fluctuation analysis, and traditional time- and frequency-domain measures from 24-hour ECG recordings. Compared with young adults (<40 years old, n=29), children (<15 years old, n=27) showed similar complexity (ApEn) and fractal correlation properties (alpha(1), alpha(2), beta) of R-R interval dynamics despite lower spectral and time-domain measures. Progressive loss of complexity (decreased ApEn, r=-0.69, P<0.001) and alterations of long-term fractal-like heart rate behavior (increased alpha(2), r=0.63, decreased beta, r=-0.60, P<0.001 for both) were observed thereafter from middle age (40 to 60 years, n=29) to old age (>60 years, n=29). CONCLUSIONS: Cardiac interbeat interval dynamics change markedly from childhood to old age in healthy subjects. Children show complexity and fractal correlation properties of R-R interval time series comparable to those of young adults, despite lower overall heart rate variability. Healthy aging is associated with R-R interval dynamics showing higher regularity and altered fractal scaling consistent with a loss of complex variability.

  4. Measuring Land Change in Coastal Zone around a Rapidly Urbanized Bay.

    PubMed

    Huang, Faming; Huang, Boqiang; Huang, Jinliang; Li, Shenghui

    2018-05-23

    Urban development is a major cause for eco-degradation in many coastal regions. Understanding urbanization dynamics and underlying driving factors is crucial for urban planning and management. Land-use dynamic degree indices and intensity analysis were used to measure land changes occurred in 1990, 2002, 2009, and 2017 in the coastal zone around Quanzhou bay, which is a rapidly urbanized bay in Southeast China. The comprehensive land-use dynamic degree and interval level intensity analysis both revealed that land change was accelerating across the three time intervals in a three-kilometer-wide zone along the coastal line (zone A), while land change was fastest during the second time interval 2002⁻2009 in a separate terrestrial area within coastal zone (zone B). Driven by urbanization, built-up gains and cropland losses were active for all time intervals in both zones. Mudflat losses were active except in the first time interval in zone A due to the intensive sea reclamation. The gain of mangrove was active while the loss of mangrove is dormant for all three intervals in zone A. Transition level analysis further revealed the similarities and differences in processes within patterns of land changes for both zones. The transition from cropland to built-up was systematically targeted and stationary while the transition from woodland to built-up was systematically avoiding transition in both zones. Built-up tended to target aquaculture for the second and third time intervals in zone A but avoid Aquaculture for all intervals in zone B. Land change in zone A was more significant than that in zone B during the second and third time intervals at three-level intensity. The application of intensity analysis can enhance our understanding of the patterns and processes in land changes and suitable land development plans in the Quanzhou bay area. This type of investigation is useful to provide information for developing sound land use policy to achieve urban sustainability in similar coastal areas.

  5. High resolution time interval counter

    DOEpatents

    Condreva, Kenneth J.

    1994-01-01

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured.

  6. High resolution time interval counter

    DOEpatents

    Condreva, K.J.

    1994-07-26

    A high resolution counter circuit measures the time interval between the occurrence of an initial and a subsequent electrical pulse to two nanoseconds resolution using an eight megahertz clock. The circuit includes a main counter for receiving electrical pulses and generating a binary word--a measure of the number of eight megahertz clock pulses occurring between the signals. A pair of first and second pulse stretchers receive the signal and generate a pair of output signals whose widths are approximately sixty-four times the time between the receipt of the signals by the respective pulse stretchers and the receipt by the respective pulse stretchers of a second subsequent clock pulse. Output signals are thereafter supplied to a pair of start and stop counters operable to generate a pair of binary output words representative of the measure of the width of the pulses to a resolution of two nanoseconds. Errors associated with the pulse stretchers are corrected by providing calibration data to both stretcher circuits, and recording start and stop counter values. Stretched initial and subsequent signals are combined with autocalibration data and supplied to an arithmetic logic unit to determine the time interval in nanoseconds between the pair of electrical pulses being measured. 3 figs.

  7. Single photon detection and timing in the Lunar Laser Ranging Experiment.

    NASA Technical Reports Server (NTRS)

    Poultney, S. K.

    1972-01-01

    The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.

  8. Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

    NASA Technical Reports Server (NTRS)

    Leskovar, B.; Turko, B.

    1977-01-01

    The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

  9. A game theoretic approach to a finite-time disturbance attenuation problem

    NASA Technical Reports Server (NTRS)

    Rhee, Ihnseok; Speyer, Jason L.

    1991-01-01

    A disturbance attenuation problem over a finite-time interval is considered by a game theoretic approach where the control, restricted to a function of the measurement history, plays against adversaries composed of the process and measurement disturbances, and the initial state. A zero-sum game, formulated as a quadratic cost criterion subject to linear time-varying dynamics and measurements, is solved by a calculus of variation technique. By first maximizing the quadratic cost criterion with respect to the process disturbance and initial state, a full information game between the control and the measurement residual subject to the estimator dynamics results. The resulting solution produces an n-dimensional compensator which expresses the controller as a linear combination of the measurement history. A disturbance attenuation problem is solved based on the results of the game problem. For time-invariant systems it is shown that under certain conditions the time-varying controller becomes time-invariant on the infinite-time interval. The resulting controller satisfies an H(infinity) norm bound.

  10. A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.

    PubMed

    Jafari Tadi, Mojtaba; Lehtonen, Eero; Hurnanen, Tero; Koskinen, Juho; Eriksson, Jonas; Pänkäälä, Mikko; Teräs, Mika; Koivisto, Tero

    2016-11-01

    Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r  >  0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.

  11. A microcomputer system for on-line study of atrioventricular node accommodation.

    PubMed

    Jenkins, J R; Clemo, H F; Belardinelli, L

    1987-11-01

    An automated on-line programmable stimulator and interval measurement system was developed to study atrioventricular node (AVN) accommodation. This dedicated microcomputer system measures and stores the stimulus-to-His bundle (S-H) interval from His bundle electrogram (HBE) recordings. Interval measurements for each beat are accurate to within 500 microsecond. This user-controlled system has been used to stimulate at any rate up to 6.5 Hz and to measure intervals up to 125 ms in isolated perfused guinea pig hearts. A built-in timer-reset mechanism prevents failure of the system in the absence of a His potential (i.e., 2:1 AV block). It may be modified for use in clinical studies or other experimental systems and has the ability to measure other physiological intervals. The system provides the precision in pacing and accuracy in the measurement of AVN conduction time that is necessary for meaningful analysis of AVN accommodation and has the simplicity of design and use that is not available in previously described systems. Furthermore, this computer system can be used not only in studies involving AV conduction, but also in any setting where programmed stimulation and interval measurement and recording need to be performed simultaneously.

  12. Method and apparatus for measuring nuclear magnetic properties

    DOEpatents

    Weitekamp, D.P.; Bielecki, A.; Zax, D.B.; Zilm, K.W.; Pines, A.

    1987-12-01

    A method for studying the chemical and structural characteristics of materials is disclosed. The method includes placement of a sample material in a high strength polarizing magnetic field to order the sample nuclei. The condition used to order the sample is then removed abruptly and the ordering of the sample allowed to evolve for a time interval. At the end of the time interval, the ordering of the sample is measured by conventional nuclear magnetic resonance techniques. 5 figs.

  13. Method and apparatus for measuring nuclear magnetic properties

    DOEpatents

    Weitekamp, Daniel P.; Bielecki, Anthony; Zax, David B.; Zilm, Kurt W.; Pines, Alexander

    1987-01-01

    A method for studying the chemical and structural characteristics of materials is disclosed. The method includes placement of a sample material in a high strength polarizing magnetic field to order the sample nucleii. The condition used to order the sample is then removed abruptly and the ordering of the sample allowed to evolve for a time interval. At the end of the time interval, the ordering of the sample is measured by conventional nuclear magnetic resonance techniques.

  14. Off-set stabilizer for comparator output

    DOEpatents

    Lunsford, James S.

    1991-01-01

    A stabilized off-set voltage is input as the reference voltage to a comparator. In application to a time-interval meter, the comparator output generates a timing interval which is independent of drift in the initial voltage across the timing capacitor. A precision resistor and operational amplifier charge a capacitor to a voltage which is precisely offset from the initial voltage. The capacitance of the reference capacitor is selected so that substantially no voltage drop is obtained in the reference voltage applied to the comparator during the interval to be measured.

  15. Combinations of Earth Orientation Measurements: SPACE2001, COMB2001, and POLE2001

    NASA Technical Reports Server (NTRS)

    Gross, Richard S.

    2002-01-01

    Independent Earth-orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth-orientation series, SPACE2001, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28.0, 1976 to January 19.0, 2002 at daily intervals. The space-geodetic measurements used to generate SPACE2001 have been combined with optical astrometric measurements to form two additional combined Earth-orientation series: (1) COMB2001, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20.0, 1962 to January 15.0, 2002 at five-day intervals, and (2) POLE2001, consisting of values and uncertainties for polar motion and its rates that span from January 20, 1900 to December 21, 2001 at 30.4375-day intervals.

  16. A quantile-based Time at Risk: A new approach for assessing risk in financial markets

    NASA Astrophysics Data System (ADS)

    Bolgorian, Meysam; Raei, Reza

    2013-11-01

    In this paper, we provide a new measure for evaluation of risk in financial markets. This measure is based on the return interval of critical events in financial markets or other investment situations. Our main goal was to devise a model like Value at Risk (VaR). As VaR, for a given financial asset, probability level and time horizon, gives a critical value such that the likelihood of loss on the asset over the time horizon exceeds this value is equal to the given probability level, our concept of Time at Risk (TaR), using a probability distribution function of return intervals, provides a critical time such that the probability that the return interval of a critical event exceeds this time equals the given probability level. As an empirical application, we applied our model to data from the Tehran Stock Exchange Price Index (TEPIX) as a financial asset (market portfolio) and reported the results.

  17. Heart-Rate Variability During Deep Sleep in World-Class Alpine Skiers: A Time-Efficient Alternative to Morning Supine Measurements.

    PubMed

    Herzig, David; Testorelli, Moreno; Olstad, Daniela Schäfer; Erlacher, Daniel; Achermann, Peter; Eser, Prisca; Wilhelm, Matthias

    2017-05-01

    It is increasingly popular to use heart-rate variability (HRV) to tailor training for athletes. A time-efficient method is HRV assessment during deep sleep. To validate the selection of deep-sleep segments identified by RR intervals with simultaneous electroencephalography (EEG) recordings and to compare HRV parameters of these segments with those of standard morning supine measurements. In 11 world-class alpine skiers, RR intervals were monitored during 10 nights, and simultaneous EEGs were recorded during 2-4 nights. Deep sleep was determined from the HRV signal and verified by delta power from the EEG recordings. Four further segments were chosen for HRV determination, namely, a 4-h segment from midnight to 4 AM and three 5-min segments: 1 just before awakening, 1 after waking in supine position, and 1 in standing after orthostatic challenge. Training load was recorded every day. A total of 80 night and 68 morning measurements of 9 athletes were analyzed. Good correspondence between the phases selected by RR intervals vs those selected by EEG was found. Concerning root-mean-squared difference of successive RR intervals (RMSSD), a marker for parasympathetic activity, the best relationship with the morning supine measurement was found in deep sleep. HRV is a simple tool for approximating deep-sleep phases, and HRV measurement during deep sleep could provide a time-efficient alternative to HRV in supine position.

  18. Observer Error when Measuring Safety-Related Behavior: Momentary Time Sampling versus Whole-Interval Recording

    ERIC Educational Resources Information Center

    Taylor, Matthew A.; Skourides, Andreas; Alvero, Alicia M.

    2012-01-01

    Interval recording procedures are used by persons who collect data through observation to estimate the cumulative occurrence and nonoccurrence of behavior/events. Although interval recording procedures can increase the efficiency of observational data collection, they can also induce error from the observer. In the present study, 50 observers were…

  19. Laser detection of material thickness

    DOEpatents

    Early, James W.

    2002-01-01

    There is provided a method for measuring material thickness comprising: (a) contacting a surface of a material to be measured with a high intensity short duration laser pulse at a light wavelength which heats the area of contact with the material, thereby creating an acoustical pulse within the material: (b) timing the intervals between deflections in the contacted surface caused by the reverberation of acoustical pulses between the contacted surface and the opposite surface of the material: and (c) determining the thickness of the material by calculating the proportion of the thickness of the material to the measured time intervals between deflections of the contacted surface.

  20. Dissociations between interval timing and intertemporal choice following administration of fluoxetine, cocaine, or methamphetamine

    PubMed Central

    Heilbronner, Sarah R.; Meck, Warren. H.

    2014-01-01

    The goal of our study was to characterize the relationship between intertemporal choice and interval timing, including determining how drugs that modulate brain serotonin and dopamine levels influence these two processes. In Experiment 1, rats were tested on a standard 40-s peak-interval procedure following administration of fluoxetine (3, 5, or 8 mg/kg) or vehicle to assess basic effects on interval timing. In Experiment 2, rats were tested in a novel behavioral paradigm intended to simultaneously examine interval timing and impulsivity. Rats performed a variant of the bi-peak procedure using 10-s and 40-s target durations with an additional “defection” lever that provided the possibility of a small, immediate reward. Timing functions remained relatively intact, and ‘patience’ across subjects correlated with peak times, indicating a negative relationship between ‘patience’ and clock speed. We next examined the effects of fluoxetine (5 mg/kg), cocaine (15 mg/kg), or methamphetamine (1 mg/kg) on task performance. Fluoxetine reduced impulsivity as measured by defection time without corresponding changes in clock speed. In contrast, cocaine and methamphetamine both increased impulsivity and clock speed. Thus, variations in timing may mediate intertemporal choice via dopaminergic inputs. However, a separate, serotonergic system can affect intertemporal choice without affecting interval timing directly. PMID:24135569

  1. A Possible Link between Supra-Second Open-Ended Timing Sensitivity and Obsessive-Compulsive Tendencies

    PubMed Central

    Gilaie-Dotan, Sharon; Ashkenazi, Hamutal; Dar, Reuven

    2016-01-01

    One of the main characteristics of obsessive-compulsive disorder (OCD) is the persistent feeling of uncertainty, affecting many domains of actions and feelings. It was recently hypothesized that OCD uncertainty is related to attenuated access to internal states. As supra-second timing is associated with bodily and interoceptive awareness, we examined whether supra-second timing would be associated with OC tendencies. We measured supra-second (~9 s) and sub-second (~450 ms) timing along with control non-temporal perceptual tasks in a group of 60 university students. Supra-second timing was measured either with fixed criterion tasks requiring to temporally discriminate between two predefined fixed interval durations (9 vs. 9.9 s), or with an open-ended task requiring to discriminate between 9 s and longer intervals which were of varying durations that were not a priori known to the participants. The open-ended task employed an adaptive Bayesian procedure that efficiently estimated the duration difference required to discriminate 9 s from longer intervals. We also assessed symptoms of OCD, depression, and anxiety. Open-ended supra-second temporal sensitivity was correlated with OC tendencies, as predicted (even after controlling for depression and anxiety), whereas the other tasks were not. Higher OC tendencies were associated with lower timing sensitivity to 9 s intervals such that participants with higher OC tendency scores required longer interval differences to discriminate 9 s from longer intervals. While these results need to be substantiated in future research, they suggest that open-ended timing tasks, as those encountered in real-life (e.g., estimating how long it would take to complete a task), might be adversely affected in OCD. PMID:27445725

  2. Estimation of the cloud transmittance from radiometric measurements at the ground level

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costa, Dario; Mares, Oana, E-mail: mareshoana@yahoo.com

    2014-11-24

    The extinction of solar radiation due to the clouds is more significant than due to any other atmospheric constituent, but it is always difficult to be modeled because of the random distribution of clouds on the sky. Moreover, the transmittance of a layer of clouds is in a very complex relation with their type and depth. A method for estimating cloud transmittance was proposed in Paulescu et al. (Energ. Convers. Manage, 75 690–697, 2014). The approach is based on the hypothesis that the structure of the cloud covering the sun at a time moment does not change significantly in amore » short time interval (several minutes). Thus, the cloud transmittance can be calculated as the estimated coefficient of a simple linear regression for the computed versus measured solar irradiance in a time interval Δt. The aim of this paper is to optimize the length of the time interval Δt. Radiometric data measured on the Solar Platform of the West University of Timisoara during 2010 at a frequency of 1/15 seconds are used in this study.« less

  3. Estimation of the cloud transmittance from radiometric measurements at the ground level

    NASA Astrophysics Data System (ADS)

    Costa, Dario; Mares, Oana

    2014-11-01

    The extinction of solar radiation due to the clouds is more significant than due to any other atmospheric constituent, but it is always difficult to be modeled because of the random distribution of clouds on the sky. Moreover, the transmittance of a layer of clouds is in a very complex relation with their type and depth. A method for estimating cloud transmittance was proposed in Paulescu et al. (Energ. Convers. Manage, 75 690-697, 2014). The approach is based on the hypothesis that the structure of the cloud covering the sun at a time moment does not change significantly in a short time interval (several minutes). Thus, the cloud transmittance can be calculated as the estimated coefficient of a simple linear regression for the computed versus measured solar irradiance in a time interval Δt. The aim of this paper is to optimize the length of the time interval Δt. Radiometric data measured on the Solar Platform of the West University of Timisoara during 2010 at a frequency of 1/15 seconds are used in this study.

  4. The dose delivery effect of the different Beam ON interval in FFF SBRT: TrueBEAM

    NASA Astrophysics Data System (ADS)

    Tawonwong, T.; Suriyapee, S.; Oonsiri, S.; Sanghangthum, T.; Oonsiri, P.

    2016-03-01

    The purpose of this study is to determine the dose delivery effect of the different Beam ON interval in Flattening Filter Free Stereotactic Body Radiation Therapy (FFF-SBRT). The three 10MV-FFF SBRT plans (2 half rotating Rapid Arc, 9 to10 Gray/Fraction) were selected and irradiated in three different intervals (100%, 50% and 25%) using the RPM gating system. The plan verification was performed by the ArcCHECK for gamma analysis and the ionization chamber for point dose measurement. The dose delivery time of each interval were observed. For gamma analysis (2%&2mm criteria), the average percent pass of all plans for 100%, 50% and 25% intervals were 86.1±3.3%, 86.0±3.0% and 86.1±3.3%, respectively. For point dose measurement, the average ratios of each interval to the treatment planning were 1.012±0.015, 1.011±0.014 and 1.011±0.013 for 100%, 50% and 25% interval, respectively. The average dose delivery time was increasing from 74.3±5.0 second for 100% interval to 154.3±12.6 and 347.9±20.3 second for 50% and 25% interval, respectively. The same quality of the dose delivery from different Beam ON intervals in FFF-SBRT by TrueBEAM was illustrated. While the 100% interval represents the breath-hold treatment technique, the differences for the free-breathing using RPM gating system can be treated confidently.

  5. The influence of CS-US interval on several different indices of learning in appetitive conditioning

    PubMed Central

    Delamater, Andrew R.; Holland, Peter C.

    2010-01-01

    Four experiments examined the effects of varying the CS-US interval (and US density) on learning in an appetitive magazine approach task with rats. Learning was assessed with conditioned response (CR) measures, as well as measures of sensory-specific stimulus-outcome associations (Pavlovian-instrumental transfer, potentiated feeding, and US devaluation). The results from these studies indicate that there exists an inverse relation between CS-US interval and magazine approach CRs, but that sensory-specific stimulus-outcome associations are established over a wide range of relatively long, but not short, CS-US intervals. These data suggest that simple CR measures provide us with different information about what is learned than measures of the specific stimulus-outcome association, and that time is a more critical variable for the former than latter component of learning. PMID:18426304

  6. Optimal Measurement Interval for Emergency Department Crowding Estimation Tools.

    PubMed

    Wang, Hao; Ojha, Rohit P; Robinson, Richard D; Jackson, Bradford E; Shaikh, Sajid A; Cowden, Chad D; Shyamanand, Rath; Leuck, JoAnna; Schrader, Chet D; Zenarosa, Nestor R

    2017-11-01

    Emergency department (ED) crowding is a barrier to timely care. Several crowding estimation tools have been developed to facilitate early identification of and intervention for crowding. Nevertheless, the ideal frequency is unclear for measuring ED crowding by using these tools. Short intervals may be resource intensive, whereas long ones may not be suitable for early identification. Therefore, we aim to assess whether outcomes vary by measurement interval for 4 crowding estimation tools. Our eligible population included all patients between July 1, 2015, and June 30, 2016, who were admitted to the JPS Health Network ED, which serves an urban population. We generated 1-, 2-, 3-, and 4-hour ED crowding scores for each patient, using 4 crowding estimation tools (National Emergency Department Overcrowding Scale [NEDOCS], Severely Overcrowded, Overcrowded, and Not Overcrowded Estimation Tool [SONET], Emergency Department Work Index [EDWIN], and ED Occupancy Rate). Our outcomes of interest included ED length of stay (minutes) and left without being seen or eloped within 4 hours. We used accelerated failure time models to estimate interval-specific time ratios and corresponding 95% confidence limits for length of stay, in which the 1-hour interval was the reference. In addition, we used binomial regression with a log link to estimate risk ratios (RRs) and corresponding confidence limit for left without being seen. Our study population comprised 117,442 patients. The time ratios for length of stay were similar across intervals for each crowding estimation tool (time ratio=1.37 to 1.30 for NEDOCS, 1.44 to 1.37 for SONET, 1.32 to 1.27 for EDWIN, and 1.28 to 1.23 for ED Occupancy Rate). The RRs of left without being seen differences were also similar across intervals for each tool (RR=2.92 to 2.56 for NEDOCS, 3.61 to 3.36 for SONET, 2.65 to 2.40 for EDWIN, and 2.44 to 2.14 for ED Occupancy Rate). Our findings suggest limited variation in length of stay or left without being seen between intervals (1 to 4 hours) regardless of which of the 4 crowding estimation tools were used. Consequently, 4 hours may be a reasonable interval for assessing crowding with these tools, which could substantially reduce the burden on ED personnel by requiring less frequent assessment of crowding. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  7. Validation of accelerometer wear and nonwear time classification algorithm.

    PubMed

    Choi, Leena; Liu, Zhouwen; Matthews, Charles E; Buchowski, Maciej S

    2011-02-01

    the use of movement monitors (accelerometers) for measuring physical activity (PA) in intervention and population-based studies is becoming a standard methodology for the objective measurement of sedentary and active behaviors and for the validation of subjective PA self-reports. A vital step in PA measurement is the classification of daily time into accelerometer wear and nonwear intervals using its recordings (counts) and an accelerometer-specific algorithm. the purpose of this study was to validate and improve a commonly used algorithm for classifying accelerometer wear and nonwear time intervals using objective movement data obtained in the whole-room indirect calorimeter. we conducted a validation study of a wear or nonwear automatic algorithm using data obtained from 49 adults and 76 youth wearing accelerometers during a strictly monitored 24-h stay in a room calorimeter. The accelerometer wear and nonwear time classified by the algorithm was compared with actual wearing time. Potential improvements to the algorithm were examined using the minimum classification error as an optimization target. the recommended elements in the new algorithm are as follows: 1) zero-count threshold during a nonwear time interval, 2) 90-min time window for consecutive zero or nonzero counts, and 3) allowance of 2-min interval of nonzero counts with the upstream or downstream 30-min consecutive zero-count window for detection of artifactual movements. Compared with the true wearing status, improvements to the algorithm decreased nonwear time misclassification during the waking and the 24-h periods (all P values < 0.001). the accelerometer wear or nonwear time algorithm improvements may lead to more accurate estimation of time spent in sedentary and active behaviors.

  8. Evaluating test-retest reliability in patient-reported outcome measures for older people: A systematic review.

    PubMed

    Park, Myung Sook; Kang, Kyung Ja; Jang, Sun Joo; Lee, Joo Yun; Chang, Sun Ju

    2018-03-01

    This study aimed to evaluate the components of test-retest reliability including time interval, sample size, and statistical methods used in patient-reported outcome measures in older people and to provide suggestions on the methodology for calculating test-retest reliability for patient-reported outcomes in older people. This was a systematic literature review. MEDLINE, Embase, CINAHL, and PsycINFO were searched from January 1, 2000 to August 10, 2017 by an information specialist. This systematic review was guided by both the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and the guideline for systematic review published by the National Evidence-based Healthcare Collaborating Agency in Korea. The methodological quality was assessed by the Consensus-based Standards for the selection of health Measurement Instruments checklist box B. Ninety-five out of 12,641 studies were selected for the analysis. The median time interval for test-retest reliability was 14days, and the ratio of sample size for test-retest reliability to the number of items in each measure ranged from 1:1 to 1:4. The most frequently used statistical methods for continuous scores was intraclass correlation coefficients (ICCs). Among the 63 studies that used ICCs, 21 studies presented models for ICC calculations and 30 studies reported 95% confidence intervals of the ICCs. Additional analyses using 17 studies that reported a strong ICC (>0.09) showed that the mean time interval was 12.88days and the mean ratio of the number of items to sample size was 1:5.37. When researchers plan to assess the test-retest reliability of patient-reported outcome measures for older people, they need to consider an adequate time interval of approximately 13days and the sample size of about 5 times the number of items. Particularly, statistical methods should not only be selected based on the types of scores of the patient-reported outcome measures, but should also be described clearly in the studies that report the results of test-retest reliability. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Fast transfer of crossmodal time interval training.

    PubMed

    Chen, Lihan; Zhou, Xiaolin

    2014-06-01

    Sub-second time perception is essential for many important sensory and perceptual tasks including speech perception, motion perception, motor coordination, and crossmodal interaction. This study investigates to what extent the ability to discriminate sub-second time intervals acquired in one sensory modality can be transferred to another modality. To this end, we used perceptual classification of visual Ternus display (Ternus in Psychol Forsch 7:81-136, 1926) to implicitly measure participants' interval perception in pre- and posttests and implemented an intra- or crossmodal sub-second interval discrimination training protocol in between the tests. The Ternus display elicited either an "element motion" or a "group motion" percept, depending on the inter-stimulus interval between the two visual frames. The training protocol required participants to explicitly compare the interval length between a pair of visual, auditory, or tactile stimuli with a standard interval or to implicitly perceive the length of visual, auditory, or tactile intervals by completing a non-temporal task (discrimination of auditory pitch or tactile intensity). Results showed that after fast explicit training of interval discrimination (about 15 min), participants improved their ability to categorize the visual apparent motion in Ternus displays, although the training benefits were mild for visual timing training. However, the benefits were absent for implicit interval training protocols. This finding suggests that the timing ability in one modality can be rapidly acquired and used to improve timing-related performance in another modality and that there may exist a central clock for sub-second temporal processing, although modality-specific perceptual properties may constrain the functioning of this clock.

  10. Crackles and instabilities during lung inflation

    NASA Astrophysics Data System (ADS)

    Alencar, Adriano M.; Majumdar, Arnab; Hantos, Zoltan; Buldyrev, Sergey V.; Eugene Stanley, H.; Suki, Béla

    2005-11-01

    In a variety of physico-chemical reactions, the actual process takes place in a reactive zone, called the “active surface”. We define the active surface of the lung as the set of airway segments that are closed but connected to the trachea through an open pathway, which is the interface between closed and open regions in a collapsed lung. To study the active surface and the time interval between consecutive openings, we measured the sound pressure of crackles, associated with the opening of collapsed airway segments in isolated dog lungs, inflating from the collapsed state in 120 s. We analyzed the sequence of crackle amplitudes, inter-crackle intervals, and low frequency energy from acoustic data. The series of spike amplitudes spans two orders of magnitude and the inter-crackle intervals spans over five orders of magnitude. The distribution of spike amplitudes follows a power law for nearly two decades, while the distribution of time intervals between consecutive crackles shows two regimes of power law behavior, where the first region represents crackles coming from avalanches of openings whereas the second region is due to the time intervals between separate avalanches. Using the time interval between measured crackles, we estimated the time evolution of the active surface during lung inflation. In addition, we show that recruitment and instabilities along the pressure-volume curve are associated with airway opening and recruitment. We find a good agreement between the theory of the dynamics of lung inflation and the experimental data which combined with numerical results may prove useful in the clinical diagnosis of lung diseases.

  11. A 45 ps time digitizer with a two-phase clock and dual-edge two-stage interpolation in a field programmable gate array device

    NASA Astrophysics Data System (ADS)

    Szplet, R.; Kalisz, J.; Jachna, Z.

    2009-02-01

    We present a time digitizer having 45 ps resolution, integrated in a field programmable gate array (FPGA) device. The time interval measurement is based on the two-stage interpolation method. A dual-edge two-phase interpolator is driven by the on-chip synthesized 250 MHz clock with precise phase adjustment. An improved dual-edge double synchronizer was developed to control the main counter. The nonlinearity of the digitizer's transfer characteristic is identified and utilized by the dedicated hardware code processor for the on-the-fly correction of the output data. Application of presented ideas has resulted in the measurement uncertainty of the digitizer below 70 ps RMS over the time interval ranging from 0 to 1 s. The use of the two-stage interpolation and a fast FIFO memory has allowed us to obtain the maximum measurement rate of five million measurements per second.

  12. Social Reinforcement Delays in Free-Flying Honey Bees (Apis mellifera L.)

    PubMed Central

    Craig, David Philip Arthur; Grice, James W.; Varnon, Chris A.; Gibson, B.; Sokolowski, Michel B. C.; Abramson, Charles I.

    2012-01-01

    Free-flying honey bees (Apis mellifera L.) reactions were observed when presented with varying schedules of post-reinforcement delays of 0 s, 300 s, or 600 s. We measured inter-visit-interval, response length, inter-response-time, and response rate. Honey bees exposed to these post-reinforcement delay intervals exhibit one of several patterns compared to groups not encountering delays, and had longer inter-visit-intervals. We observed no group differences in inter-response time. Honey bees with higher response rates tended to not finish the experiment. The removal of the delay intervals increased response rates for those subjects that completed the trials. PMID:23056425

  13. The STEP model: Characterizing simultaneous time effects on practice for flight simulator performance among middle-aged and older pilots

    PubMed Central

    Kennedy, Quinn; Taylor, Joy; Noda, Art; Yesavage, Jerome; Lazzeroni, Laura C.

    2015-01-01

    Understanding the possible effects of the number of practice sessions (practice) and time between practice sessions (interval) among middle-aged and older adults in real world tasks has important implications for skill maintenance. Prior training and cognitive ability may impact practice and interval effects on real world tasks. In this study, we took advantage of existing practice data from five simulated flights among 263 middle-aged and older pilots with varying levels of flight expertise (defined by FAA proficiency ratings). We developed a new STEP (Simultaneous Time Effects on Practice) model to: (1) model the simultaneous effects of practice and interval on performance of the five flights, and (2) examine the effects of selected covariates (age, flight expertise, and three composite measures of cognitive ability). The STEP model demonstrated consistent positive practice effects, negative interval effects, and predicted covariate effects. Age negatively moderated the beneficial effects of practice. Additionally, cognitive processing speed and intra-individual variability (IIV) in processing speed moderated the benefits of practice and/or the negative influence of interval for particular flight performance measures. Expertise did not interact with either practice or interval. Results indicate that practice and interval effects occur in simulated flight tasks. However, processing speed and IIV may influence these effects, even among high functioning adults. Results have implications for the design and assessment of training interventions targeted at middle-aged and older adults for complex real world tasks. PMID:26280383

  14. Considerations for Time Sampling Interval Durations in the Measurement of Young Children's Classroom Engagement

    ERIC Educational Resources Information Center

    Zakszeski, Brittany N.; Hojnoski, Robin L.; Wood, Brenna K.

    2017-01-01

    Classroom engagement is important to young children's academic and social development. Accurate methods of capturing this behavior are needed to inform and evaluate intervention efforts. This study compared the accuracy of interval durations (i.e., 5 s, 10 s, 15 s, 20 s, 30 s, and 60 s) of momentary time sampling (MTS) in approximating the…

  15. Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables.

    PubMed

    Baek, Hyun Jae; Shin, JaeWook

    2017-08-15

    Most of the wrist-worn devices on the market provide a continuous heart rate measurement function using photoplethysmography, but have not yet provided a function to measure the continuous heart rate variability (HRV) using beat-to-beat pulse interval. The reason for such is the difficulty of measuring a continuous pulse interval during movement using a wearable device because of the nature of photoplethysmography, which is susceptible to motion noise. This study investigated the effect of missing heart beat interval data on the HRV analysis in cases where pulse interval cannot be measured because of movement noise. First, we performed simulations by randomly removing data from the RR interval of the electrocardiogram measured from 39 subjects and observed the changes of the relative and normalized errors for the HRV parameters according to the total length of the missing heart beat interval data. Second, we measured the pulse interval from 20 subjects using a wrist-worn device for 24 h and observed the error value for the missing pulse interval data caused by the movement during actual daily life. The experimental results showed that mean NN and RMSSD were the most robust for the missing heart beat interval data among all the parameters in the time and frequency domains. Most of the pulse interval data could not be obtained during daily life. In other words, the sample number was too small for spectral analysis because of the long missing duration. Therefore, the frequency domain parameters often could not be calculated, except for the sleep state with little motion. The errors of the HRV parameters were proportional to the missing data duration in the presence of missing heart beat interval data. Based on the results of this study, the maximum missing duration for acceptable errors for each parameter is recommended for use when the HRV analysis is performed on a wrist-worn device.

  16. Constant-load versus heart rate-targeted exercise - Responses of systolic intervals

    NASA Technical Reports Server (NTRS)

    Lance, V. Q.; Spodick, D. H.

    1975-01-01

    Various systolic intervals were measured prior to and during heart rate-targeted bicycle ergometer exercise. There were striking similarities within each matched exercise set for Q-Im, isovolumetric contraction time, preejection period (PEP), and PEP/left ventricular ejection time (LVET). LVET was significantly shorter for rate-targeted exercise. It is concluded that either constant-load or rate-targeted bicycle ergometry may be used with the choice of method determined by the purpose of the protocol, and that systolic intervals (except LVET) should not be much altered owing to the method chosen.

  17. Dynamic Parameters Variability: Time Interval Interference on Ground Reaction Force During Running.

    PubMed

    Pennone, Juliana; Mezêncio, Bruno; Amadio, Alberto C; Serrão, Júlio C

    2016-04-01

    The aim of this study was to determine the effect of the time between measures on ground reaction force running variability; 15 healthy men (age = 23.8 ± 3.7 years; weight = 72.8 ± 7.7 kg; height 174.3 ± 8.4 cm) performed two trials of running 45 minutes at 9 km/hr at intervals of seven days. The ground reaction forces were recorded every 5 minutes. The coefficients of variation of indicative parameters of the ground reaction forces for each condition were compared. The coefficients of variations of the ground reaction forces curve analyzed between intervals and sessions were 21.9% and 21.48%, respectively. There was no significant difference for the ground reaction forces parameters Fy1, tFy1, TC1, Imp50, Fy2, and tFy2 between intervals and sessions. Although the ground reaction forces variables present a natural variability, this variability in intervals and in sessions remained consistent, ensuring a high reliability in repeated measures designs. © The Author(s) 2016.

  18. Factors influencing pre-hospital care time intervals in Iran: a qualitative study.

    PubMed

    Khorasani-Zavareh, Davoud; Mohammadi, Reza; Bohm, Katarina

    2018-06-23

    Pre-hospital time management provides better access to victims of road traffic crashes (RTCs) and can help minimize preventable deaths, injuries and disabilities. While most studies have been focused on measuring various time intervals in the pre-hospital phase, to our best knowledge there is no study exploring the barriers and facilitators that affects these various intervals qualitatively. The present study aimed to explore factors affecting various time intervals relating to road traffic incidents in the pre-hospital phase and provides suggestions for improvements in Iran. The study was conducted during 2013-2014 at both the national and local level in Iran. Overall, 18 face-to-face interviews with emergency medical services (EMS) personnel were used for data collection. Qualitative content analysis was employed to analyze the data. The most important barriers in relation to pre-hospital intervals were related to the manner of cooperation by members of the public with the EMS and their involvement at the crash scene, as well as to pre-hospital system factors, including the number and location of EMS facilities, type and number of ambulances and manpower. These factors usually affect how rapidly the EMS can arrive at the scene of the crash and how quickly victims can be transferred to hospital. These two categories have six main themes: notification interval; activation interval; response interval; on-scene interval; transport interval; and delivery interval. Despite more focus on physical resources, cooperation from members of the public needs to be taken in account in order to achieve better pre-hospital management of the various intervals, possibly through the use of public education campaigns.

  19. Multiresolution Wavelet Analysis of Heartbeat Intervals Discriminates Healthy Patients from Those with Cardiac Pathology

    NASA Astrophysics Data System (ADS)

    Thurner, Stefan; Feurstein, Markus C.; Teich, Malvin C.

    1998-02-01

    We applied multiresolution wavelet analysis to the sequence of times between human heartbeats ( R-R intervals) and have found a scale window, between 16 and 32 heartbeat intervals, over which the widths of the R-R wavelet coefficients fall into disjoint sets for normal and heart-failure patients. This has enabled us to correctly classify every patient in a standard data set as belonging either to the heart-failure or normal group with 100% accuracy, thereby providing a clinically significant measure of the presence of heart failure from the R-R intervals alone. Comparison is made with previous approaches, which have provided only statistically significant measures.

  20. The error and bias of supplementing a short, arid climate, rainfall record with regional vs. global frequency analysis

    NASA Astrophysics Data System (ADS)

    Endreny, Theodore A.; Pashiardis, Stelios

    2007-02-01

    SummaryRobust and accurate estimates of rainfall frequencies are difficult to make with short, and arid-climate, rainfall records, however new regional and global methods were used to supplement such a constrained 15-34 yr record in Cyprus. The impact of supplementing rainfall frequency analysis with the regional and global approaches was measured with relative bias and root mean square error (RMSE) values. Analysis considered 42 stations with 8 time intervals (5-360 min) in four regions delineated by proximity to sea and elevation. Regional statistical algorithms found the sites passed discordancy tests of coefficient of variation, skewness and kurtosis, while heterogeneity tests revealed the regions were homogeneous to mildly heterogeneous. Rainfall depths were simulated in the regional analysis method 500 times, and then goodness of fit tests identified the best candidate distribution as the general extreme value (GEV) Type II. In the regional analysis, the method of L-moments was used to estimate location, shape, and scale parameters. In the global based analysis, the distribution was a priori prescribed as GEV Type II, a shape parameter was a priori set to 0.15, and a time interval term was constructed to use one set of parameters for all time intervals. Relative RMSE values were approximately equal at 10% for the regional and global method when regions were compared, but when time intervals were compared the global method RMSE had a parabolic-shaped time interval trend. Relative bias values were also approximately equal for both methods when regions were compared, but again a parabolic-shaped time interval trend was found for the global method. The global method relative RMSE and bias trended with time interval, which may be caused by fitting a single scale value for all time intervals.

  1. New Estimates of Intergenerational Time Intervals for the Calculation of Age and Origins of Mutations

    PubMed Central

    Tremblay, Marc; Vézina, Hélène

    2000-01-01

    Summary Intergenerational time intervals are frequently used in human population-genetics studies concerned with the ages and origins of mutations. In most cases, mean intervals of 20 or 25 years are used, regardless of the demographic characteristics of the population under study. Although these characteristics may vary from prehistoric to historical times, we suggest that this value is probably too low, and that the ages of some mutations may have been underestimated. Analyses were performed by using the BALSAC Population Register (Quebec, Canada), from which several intergenerational comparisons can be made. Family reconstitutions were used to measure interval lengths and variations in descending lineages. Various parameters were considered, such as spouse age at marriage, parental age, and reproduction levels. Mother-child and father-child intervals were compared. Intergenerational male and female intervals were also analyzed in 100 extended ascending genealogies. Results showed that a mean value of 30 years is a better estimate of intergenerational intervals than 20 or 25 years. As marked differences between male and female interval length were observed, specific values are proposed for mtDNA, autosomal, X-chromosomal, and Y-chromosomal loci. The applicability of these results for age estimates of mutations is discussed. PMID:10677323

  2. The effects of morphine on fixed-interval patterning and temporal discrimination.

    PubMed Central

    Odum, A L; Schaal, D W

    2000-01-01

    Changes produced by drugs in response patterns under fixed-interval schedules of reinforcement have been interpreted to result from changes in temporal discrimination. To examine this possibility, this experiment determined the effects of morphine on the response patterning of 4 pigeons during a fixed-interval 1-min schedule of food delivery with interpolated temporal discrimination trials. Twenty of the 50 total intervals were interrupted by choice trials. Pecks to one key color produced food if the interval was interrupted after a short time (after 2 or 4.64 s). Pecks to another key color produced food if the interval was interrupted after a long time (after 24.99 or 58 s). Morphine (1.0 to 10.0 mg/kg) decreased the index of curvature (a measure of response patterning) during fixed intervals and accuracy during temporal discrimination trials. Accuracy was equally disrupted following short and long sample durations. Although morphine disrupted temporal discrimination in the context of a fixed-interval schedule, these effects are inconsistent with interpretations of the disruption of response patterning as a selective overestimation of elapsed time. The effects of morphine may be related to the effects of more conventional external stimuli on response patterning. PMID:11029024

  3. Atmospheric measurements on Mars - The Viking meteorology experiment

    NASA Technical Reports Server (NTRS)

    Chamberlain, T. E.; Cole, H. L.; Dutton, R. G.; Greene, G. C.; Tillman, J. E.

    1976-01-01

    The Viking meteorology experiment is one of nine experiments to be carried out on the surface of Mars by each of two Viking Landers positioned at different latitudes and longitudes in the Northern Hemisphere. The meteorology experiment will measure pressure, temperature, wind speed, and wind direction at 1.5-hr intervals throughout the Martian day. The duration of each measurement period, the interval between data samples for a measurement period, and the time at which the measurement period is started will be varied throughout the mission. The scientific investigation and the sensors and electronics used for making the atmospheric measurement are discussed.

  4. Muscles innervated by a single motor neuron exhibit divergent synaptic properties on multiple time scales.

    PubMed

    Blitz, Dawn M; Pritchard, Amy E; Latimer, John K; Wakefield, Andrew T

    2017-04-01

    Adaptive changes in the output of neural circuits underlying rhythmic behaviors are relayed to muscles via motor neuron activity. Presynaptic and postsynaptic properties of neuromuscular junctions can impact the transformation from motor neuron activity to muscle response. Further, synaptic plasticity occurring on the time scale of inter-spike intervals can differ between multiple muscles innervated by the same motor neuron. In rhythmic behaviors, motor neuron bursts can elicit additional synaptic plasticity. However, it is unknown whether plasticity regulated by the longer time scale of inter-burst intervals also differs between synapses from the same neuron, and whether any such distinctions occur across a physiological activity range. To address these issues, we measured electrical responses in muscles innervated by a chewing circuit neuron, the lateral gastric (LG) motor neuron, in a well-characterized small motor system, the stomatogastric nervous system (STNS) of the Jonah crab, Cancer borealis In vitro and in vivo , sensory, hormonal and modulatory inputs elicit LG bursting consisting of inter-spike intervals of 50-250 ms and inter-burst intervals of 2-24 s. Muscles expressed similar facilitation measured with paired stimuli except at the shortest inter-spike interval. However, distinct decay time constants resulted in differences in temporal summation. In response to bursting activity, augmentation occurred to different extents and saturated at different inter-burst intervals. Further, augmentation interacted with facilitation, resulting in distinct intra-burst facilitation between muscles. Thus, responses of multiple target muscles diverge across a physiological activity range as a result of distinct synaptic properties sensitive to multiple time scales. © 2017. Published by The Company of Biologists Ltd.

  5. Atmospheric Fluctuation Measurements with the Palomar Testbed Interferometer

    NASA Astrophysics Data System (ADS)

    Linfield, R. P.; Lane, B. F.; Colavita, M. M.; PTI Collaboration

    Observations of bright stars with the Palomar Testbed Interferometer, at a wavelength of 2.2 microns, have been used to measure atmospheric delay fluctuations. The delay structure function Dτ(Δ t) was calculated for 66 scans (each >= 120s in length) on seven nights in 1997 and one in 1998. For all except one scan, Dτ exhibited a clean power law shape over the time interval 50-500 msec. Over shorter time intervals, the effect of the delay line servo loop corrupts Dτ. Over longer time intervals (usually starting at > 1s), the slope of Dτ decreases, presumably due to some combination of saturation e.g. finite turbulent layer thickness) and the effect of the finite wind speed crossing time on our 110 m baseline. The mean power law slopes for the eight nights ranged from 1.16 to 1.36, substantially flatter than the value of 1.67 for three dimensional Kolmogorov turbulence. Such sub-Kolmogorov slopes will result in atmospheric seeling (θ) that improves rapidly with increasing wavelength: θ propto λ1-(2β), where β is the observed power law slope of Dτ. The atmospheric errors in astrometric measurements with an interferometer will average down more quickly than in the Kolmogorov case.

  6. Index of Refraction Measurements Using a Laser Distance Meter

    ERIC Educational Resources Information Center

    Ochoa, Romulo; Fiorillo, Richard; Ochoa, Cris

    2014-01-01

    We present a simple method to determine the refractive indices of transparent media using a laser distance meter. Indices of refraction have been obtained by measuring the speed of light in materials. Some speed of light techniques use time-of-flight measurements in which pulses are emitted by lasers and the time interval is measured for the pulse…

  7. Time variations of solar UV irradiance as measured by the SOLSTICE (UARS) instrument

    NASA Technical Reports Server (NTRS)

    London, Julius; Rottman, Gary J.; Woods, Thomas N.; Wu, Fie

    1993-01-01

    An analysis is presented of solar ultraviolet irradiance measurements made by the SOLSTICE spectrometers on the Upper Atmosphere Research Satellite (UARS). Reported observations cover the wavelength interval 119-420 nm, and the analysis discussed here is for the time period 26 Nov 1991 to 31 Dec 1992, during which time solar activity decreased in intensity. At the time of peak activity, the average 27-day variation had a relative amplitude of about 8 percent at Ly-alpha, tailing off to about 0.6 percent at 260 nm. It is shown that over the spectral interval 119-260 nm, the relative 27-day harmonic was about a factor of two larger during the strongly disturbed as compared with the moderately disturbed period.

  8. Resting multilayer 2D speckle-tracking TTE for detection of ischemic segments confirmed by invasive FFR part-2, using post-systolic-strain-index and time from aortic-valve-closure to regional peak longitudinal-strain.

    PubMed

    Ozawa, Koya; Funabashi, Nobusada; Nishi, Takeshi; Takahara, Masayuki; Fujimoto, Yoshihide; Kamata, Tomoko; Kobayashi, Yoshio

    2016-08-15

    This study evaluated the post-systolic strain index (PSI), and the time interval between aortic valve closure (AVC) and regional peak longitudinal strain (PLS), measured by transthoracic echocardiography (TTE), for detection of left ventricular (LV) myocardial ischemic segments confirmed by invasive fractional flow reserve (FFR). 39 stable patients (32 males; 65.8±11.9years) with 46 coronary arteries at ≥50% stenosis on invasive coronary angiography underwent 2D speckle tracking TTE (Vivid E9, GE Healthcare) and invasive FFR measurements. PSI, AVC and regional PLS in each LV segment were calculated. FFR ≤0.80 was detected in 27 LV segments. There were no significant differences between segments supplied by FFR ≤0.80 and FFR >0.80 vessels in either PSI or the time interval between AVC and regional PLS. To identify LV segments±FFR ≤0.80, the receiver operator characteristic (ROC) curves for PSI, and the time interval between AVC and regional PLS had areas under the curve (AUC) values of 0.58 and 0.57, respectively, with best cut-off points of 12% (sensitivity 70.4%, specificity 57.9%) and 88ms (sensitivity 70.4%, specificity 52.6%), respectively, but the AUCs were not statistically significant. In stable coronary artery disease patients with ≥50% coronary artery stenosis, measurement of PSI, and the time interval between AVC and regional PLS, on resting TTE, enabled the identification of LV segments with FFR ≤0.80 using each appropriate threshold for PSI, and the time interval between AVC and regional PLS, with reasonable diagnostic accuracy. However, the AUC values were not statistically significant. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. The Pace of Cultural Evolution

    PubMed Central

    Perreault, Charles

    2012-01-01

    Today, humans inhabit most of the world’s terrestrial habitats. This observation has been explained by the fact that we possess a secondary inheritance mechanism, culture, in addition to a genetic system. Because it is assumed that cultural evolution occurs faster than biological evolution, humans can adapt to new ecosystems more rapidly than other animals. This assumption, however, has never been tested empirically. Here, I compare rates of change in human technologies to rates of change in animal morphologies. I find that rates of cultural evolution are inversely correlated with the time interval over which they are measured, which is similar to what is known for biological rates. This correlation explains why the pace of cultural evolution appears faster when measured over recent time periods, where time intervals are often shorter. Controlling for the correlation between rates and time intervals, I show that (1) cultural evolution is faster than biological evolution; (2) this effect holds true even when the generation time of species is controlled for; and (3) culture allows us to evolve over short time scales, which are normally accessible only to short-lived species, while at the same time allowing for us to enjoy the benefits of having a long life history. PMID:23024804

  10. Temporal Variability in the Deglutition Literature

    PubMed Central

    Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    A literature review was conducted on temporal measures of swallowing in healthy individuals with the purpose of determining the degree of variability present in such measures within the literature. A total of 46 studies that met inclusion criteria were reviewed. The definitions and descriptive statistics for all reported temporal parameters were compiled for meta-analysis. In total, 119 different temporal parameters were found in the literature. The three most-frequently occurring durational measures were: UES opening, laryngeal closure and hyoid movement. The three most-frequently occurring interval measures were: stage transition duration, pharyngeal transit time and duration from laryngeal closure to UES opening. Subtle variations in operational definitions across studies were noted, making the comparison of data challenging. Analysis of forest plots compiling descriptive statistical data (means and 95% confidence intervals) across studies revealed differing degrees of variability across durations and intervals. Two parameters (UES opening duration and the laryngeal-closure-to-UES-opening interval) demonstrated the least variability, reflected by small ranges for mean values and tight confidence intervals. Trends emerged for factors of bolus size and participant age for some variables. Other potential sources of variability are discussed. PMID:22366761

  11. TOT measurement implemented in FPGA TDC

    NASA Astrophysics Data System (ADS)

    Fan, Huan-Huan; Cao, Ping; Liu, Shu-Bin; An, Qi

    2015-11-01

    Time measurement plays a crucial role for the purpose of particle identification in high energy physics experiments. With increasingly demanding physics goals and the development of electronics, modern time measurement systems need to meet the requirement of excellent resolution specification as well as high integrity. Based on Field Programmable Gate Arrays (FPGAs), FPGA time-to-digital converters (TDCs) have become one of the most mature and prominent time measurement methods in recent years. For correcting the time-walk effect caused by leading timing, a time-over-threshold (TOT) measurement should be added to the FPGA TDC. TOT can be obtained by measuring the interval between the signal leading and trailing edges. Unfortunately, a traditional TDC can recognize only one kind of signal edge, the leading or the trailing. Generally, to measure the interval, two TDC channels need to be used at the same time, one for leading, the other for trailing. However, this method unavoidably increases the amount of FPGA resources used and reduces the TDC's integrity. This paper presents one method of TOT measurement implemented in a Xilinx Virtex-5 FPGA. In this method, TOT measurement can be achieved using only one TDC input channel. The consumed resources and time resolution can both be guaranteed. Testing shows that this TDC can achieve resolution better than 15ps for leading edge measurement and 37 ps for TOT measurement. Furthermore, the TDC measurement dead time is about two clock cycles, which makes it good for applications with higher physics event rates. Supported by National Natural Science Foundation of China (11079003, 10979003)

  12. The STEP model: Characterizing simultaneous time effects on practice for flight simulator performance among middle-aged and older pilots.

    PubMed

    Kennedy, Quinn; Taylor, Joy; Noda, Art; Yesavage, Jerome; Lazzeroni, Laura C

    2015-09-01

    Understanding the possible effects of the number of practice sessions (practice) and time between practice sessions (interval) among middle-aged and older adults in real-world tasks has important implications for skill maintenance. Prior training and cognitive ability may impact practice and interval effects on real-world tasks. In this study, we took advantage of existing practice data from 5 simulated flights among 263 middle-aged and older pilots with varying levels of flight expertise (defined by U.S. Federal Aviation Administration proficiency ratings). We developed a new Simultaneous Time Effects on Practice (STEP) model: (a) to model the simultaneous effects of practice and interval on performance of the 5 flights, and (b) to examine the effects of selected covariates (i.e., age, flight expertise, and 3 composite measures of cognitive ability). The STEP model demonstrated consistent positive practice effects, negative interval effects, and predicted covariate effects. Age negatively moderated the beneficial effects of practice. Additionally, cognitive processing speed and intraindividual variability (IIV) in processing speed moderated the benefits of practice and/or the negative influence of interval for particular flight performance measures. Expertise did not interact with practice or interval. Results indicated that practice and interval effects occur in simulated flight tasks. However, processing speed and IIV may influence these effects, even among high-functioning adults. Results have implications for the design and assessment of training interventions targeted at middle-aged and older adults for complex real-world tasks. (c) 2015 APA, all rights reserved).

  13. Enhanced ionization of the Martian nightside ionosphere during solar energetic particle events

    NASA Astrophysics Data System (ADS)

    Nemec, F.; Morgan, D. D.; Dieval, C.; Gurnett, D. A.; Futaana, Y.

    2013-12-01

    The nightside ionosphere of Mars is highly variable and very irregular, controlled to a great extent by the configuration of the crustal magnetic fields. The ionospheric reflections observed by the MARSIS radar sounder on board the Mars Express spacecraft in this region are typically oblique (reflection by a distant feature), so that they cannot be used to determine the peak altitude precisely. Nevertheless, the peak electron density can be in principle readily determined. However, in more than 90% of measurements the peak electron densities are too low to be detected. We focus on the time intervals of solar energetic particle (SEP) events. One may expect high energy particle precipitation into the nightside ionosphere to increase the electron density there. Thus, comparison of characteristics between SEP/no-SEP time intervals is important to understand the formation mechanism of the nightside ionosphere. The time intervals of SEP events are determined using the increase in the background counts recorded by the ion sensor (IMA) of the ASPERA-3 particle instrument on board Mars Express. Then we use MARSIS measurements to determine how much the nightside ionosphere is enhanced during these time intervals. We show that the peak electron densities during these periods are large enough to be detected in more than 30% of measurements, while the reflections from the ground almost entirely disappear, indicating that the nightside electron densities are tremendously increased as compared to the normal nightside conditions. The influence of various parameters on the formation of the nightside ionosphere is thoroughly discussed.

  14. Variance of discharge estimates sampled using acoustic Doppler current profilers from moving boats

    USGS Publications Warehouse

    Garcia, Carlos M.; Tarrab, Leticia; Oberg, Kevin; Szupiany, Ricardo; Cantero, Mariano I.

    2012-01-01

    This paper presents a model for quantifying the random errors (i.e., variance) of acoustic Doppler current profiler (ADCP) discharge measurements from moving boats for different sampling times. The model focuses on the random processes in the sampled flow field and has been developed using statistical methods currently available for uncertainty analysis of velocity time series. Analysis of field data collected using ADCP from moving boats from three natural rivers of varying sizes and flow conditions shows that, even though the estimate of the integral time scale of the actual turbulent flow field is larger than the sampling interval, the integral time scale of the sampled flow field is on the order of the sampling interval. Thus, an equation for computing the variance error in discharge measurements associated with different sampling times, assuming uncorrelated flow fields is appropriate. The approach is used to help define optimal sampling strategies by choosing the exposure time required for ADCPs to accurately measure flow discharge.

  15. Time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems.

    PubMed

    Matityahu, Amir; Elliott, Iain; Marmor, Meir; Caldwell, Amber; Coughlin, Richard; Gosselin, Richard A

    2014-01-01

    To investigate the use of time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems. Time intervals from injury to admission, admission to surgery and surgery to discharge for patients with isolated femur fractures in four low- and middle-income countries were compared with the corresponding values from one German hospital, an Israeli hospital and the National Trauma Data Bank of the United States of America by means of Student's t-tests. The correlations between the time intervals recorded in a country and that country's expenditure on health and gross domestic product (GDP) were also evaluated using Pearson's product moment correlation coefficient. Relative to patients from high-income countries, those from low- and middle-income countries were significantly more likely to be male and to have been treated by open femoral nailing, and their intervals from injury to admission, admission to surgery and surgery to discharge were significantly longer. Strong negative correlations were detected between the interval from injury to admission and government expenditure on health, and between the interval from admission to surgery and the per capita values for total expenditure on health, government expenditure on health and GDP. Strong positive correlations were detected between the interval from surgery to discharge and general government expenditure on health. The time intervals for the treatment of femur fractures are relatively long in low- and middle-income countries, can easily be measured, and are highly correlated with accessible and quantifiable country data on health and economics.

  16. Characterization of Cardiac Time Intervals in Healthy Bonnet Macaques (Macaca radiata) by Using an Electronic Stethoscope

    PubMed Central

    Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M

    2011-01-01

    Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218

  17. Repeated stimulation, inter-stimulus interval and inter-electrode distance alters muscle contractile properties as measured by Tensiomyography

    PubMed Central

    Johnson, Mark I.; Francis, Peter

    2018-01-01

    Context The influence of methodological parameters on the measurement of muscle contractile properties using Tensiomyography (TMG) has not been published. Objective To investigate the; (1) reliability of stimulus amplitude needed to elicit maximum muscle displacement (Dm), (2) effect of changing inter-stimulus interval on Dm (using a fixed stimulus amplitude) and contraction time (Tc), (3) the effect of changing inter-electrode distance on Dm and Tc. Design Within subject, repeated measures. Participants 10 participants for each objective. Main outcome measures Dm and Tc of the rectus femoris, measured using TMG. Results The coefficient of variance (CV) and the intra-class correlation (ICC) of stimulus amplitude needed to elicit maximum Dm was 5.7% and 0.92 respectively. Dm was higher when using an inter-electrode distance of 7cm compared to 5cm [P = 0.03] and when using an inter-stimulus interval of 10s compared to 30s [P = 0.017]. Further analysis of inter-stimulus interval data, found that during 10 repeated stimuli Tc became faster after the 5th measure when compared to the second measure [P<0.05]. The 30s inter-stimulus interval produced the most stable Tc over 10 measures compared to 10s and 5s respectively. Conclusion Our data suggest that the stimulus amplitude producing maximum Dm of the rectus femoris is reliable. Inter-electrode distance and inter-stimulus interval can significantly influence Dm and/ or Tc. Our results support the use of a 30s inter-stimulus interval over 10s or 5s. Future studies should determine the influence of methodological parameters on muscle contractile properties in a range of muscles. PMID:29451885

  18. Calibration method helps in seismic velocity interpretation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guzman, C.E.; Davenport, H.A.; Wilhelm, R.

    1997-11-03

    Acoustic velocities derived from seismic reflection data, when properly calibrated to subsurface measurements, help interpreters make pure velocity predictions. A method of calibrating seismic to measured velocities has improved interpretation of subsurface features in the Gulf of Mexico. In this method, the interpreter in essence creates a kind of gauge. Properly calibrated, the gauge enables the interpreter to match predicted velocities to velocities measured at wells. Slow-velocity zones are of special interest because they sometimes appear near hydrocarbon accumulations. Changes in velocity vary in strength with location; the structural picture is hidden unless the variations are accounted for by mappingmore » in depth instead of time. Preliminary observations suggest that the presence of hydrocarbons alters the lithology in the neighborhood of the trap; this hydrocarbon effect may be reflected in the rock velocity. The effect indicates a direct use of seismic velocity in exploration. This article uses the terms seismic velocity and seismic stacking velocity interchangeably. It uses ground velocity, checkshot average velocity, and well velocity interchangeably. Interval velocities are derived from seismic stacking velocities or well average velocities; they refer to velocities of subsurface intervals or zones. Interval travel time (ITT) is the reciprocal of interval velocity in microseconds per foot.« less

  19. Automated Interval velocity picking for Atlantic Multi-Channel Seismic Data

    NASA Astrophysics Data System (ADS)

    Singh, Vishwajit

    2016-04-01

    This paper described the challenge in developing and testing a fully automated routine for measuring interval velocities from multi-channel seismic data. Various approaches are employed for generating an interactive algorithm picking interval velocity for continuous 1000-5000 normal moveout (NMO) corrected gather and replacing the interpreter's effort for manual picking the coherent reflections. The detailed steps and pitfalls for picking the interval velocities from seismic reflection time measurements are describe in these approaches. Key ingredients these approaches utilized for velocity analysis stage are semblance grid and starting model of interval velocity. Basin-Hopping optimization is employed for convergence of the misfit function toward local minima. SLiding-Overlapping Window (SLOW) algorithm are designed to mitigate the non-linearity and ill- possessedness of root-mean-square velocity. Synthetic data case studies addresses the performance of the velocity picker generating models perfectly fitting the semblance peaks. A similar linear relationship between average depth and reflection time for synthetic model and estimated models proposed picked interval velocities as the starting model for the full waveform inversion to project more accurate velocity structure of the subsurface. The challenges can be categorized as (1) building accurate starting model for projecting more accurate velocity structure of the subsurface, (2) improving the computational cost of algorithm by pre-calculating semblance grid to make auto picking more feasible.

  20. Raindrop intervalometer

    NASA Astrophysics Data System (ADS)

    van de Giesen, Nicolaas; Hut, Rolf; ten Veldhuis, Marie-claire

    2017-04-01

    If one can assume that drop size distributions can be effectively described by a generalized gamma function [1], one can estimate this function on the basis of the distribution of time intervals between drops hitting a certain area. The arrival of a single drop is relatively easy to measure with simple consumer devices such as cameras or piezoelectric elements. Here we present an open-hardware design for the electronics and statistical processing of an intervalometer that measures time intervals between drop arrivals. The specific hardware in this case is a piezoelectric element in an appropriate housing, combined with an instrumentation op-amp and an Arduino processor. Although it would not be too difficult to simply register the arrival times of all drops, it is more practical to only report the main statistics. For this purpose, all intervals below a certain threshold during a reporting interval are summed and counted. We also sum the scaled squares, cubes, and fourth powers of the intervals. On the basis of the first four moments, one can estimate the corresponding generalized gamma function and obtain some sense of the accuracy of the underlying assumptions. Special attention is needed to determine the lower threshold of the drop sizes that can be measured. This minimum size often varies over the area being monitored, such as is the case for piezoelectric elements. We describe a simple method to determine these (distributed) minimal drop sizes and present a bootstrap method to make the necessary corrections. Reference [1] Uijlenhoet, R., and J. N. M. Stricker. "A consistent rainfall parameterization based on the exponential raindrop size distribution." Journal of Hydrology 218, no. 3 (1999): 101-127.

  1. Combinations of Earth Orientation Measurements: SPACE2005, COMB2005, and POLE2005

    NASA Technical Reports Server (NTRS)

    Gross, Richard S.

    2006-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, by very long baseline interferometry, and by the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2005, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 7, 2006, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2005 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2005, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 7, 2006, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon; and (2) POLE2005, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to December 21, 2005, at 30.4375-day intervals.

  2. Combinations of Earth Orientation Measurements: SPACE2003, COMB2003, and POLE2003

    NASA Technical Reports Server (NTRS)

    Gross, Richard S.

    2004-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2003, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28.0, 1976 to January 31.0, 2004 at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2003 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2003, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20.0, 1962 to January 31.0, 2004 at daily intervals and which is also available in versions whose epochs are given at either midnight or noon, and (2) POLE2003, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900 to January 21,2004 at 30.4375-day intervals.

  3. Combinations of Earth Orientation Measurements: SPACE2004, COMB2004, and POLE2004

    NASA Technical Reports Server (NTRS)

    Gross, Richard R.

    2005-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the global positioning system have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2004, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to January 22, 2005, at daily intervals and is available in versions whose epochs are given at either midnight or noon. The space-geodetic measurements used to generate SPACE2004 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2004, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to January 22, 2005, at daily intervals and which is also available in versions whose epochs are given at either midnight or noon, and (2) POLE2004, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to January 20, 2005, at 30.4375-day intervals.

  4. Combinations of Earth Orientation Measurements: SPACE2014, COMB2014, and POLE2014

    NASA Technical Reports Server (NTRS)

    Ratcliff, J. T.; Gross, R. S.

    2015-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2013, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2014, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2013 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2013, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2014, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2013, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2014, at 30.4375-day intervals.

  5. Combinations of Earth Orientation Measurements: SPACE2011, COMB2011, and POLE2011

    NASA Technical Reports Server (NTRS)

    Ratcliff, J. T.; Gross, R. S.

    2013-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2011, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to July 13, 2012, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2011 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2011, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to July 13, 2012, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2011, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 21, 2012, at 30.4375-day intervals.

  6. Combinations of Earth Orientation Measurements: SPACE2013, COMB2013, and POLE2013

    NASA Technical Reports Server (NTRS)

    Ratcliff, J. T.; Gross, R. S.

    2015-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2013, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2014, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2013 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2013, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2014, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2013, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2014, at 30.4375-day intervals.

  7. Combinations of Earth Orientation Measurements: SPACE2016, COMB2016, and POLE2016

    NASA Technical Reports Server (NTRS)

    Ratcliff, J. T.; Gross, R. S.

    2017-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2016, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to June 30, 2017, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2016 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2016, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to June 30, 2017, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2016, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to June 22, 2017, at 30.4375-day intervals.

  8. Combinations of Earth Orientation Measurements: SPACE2012, COMB2012, and POLE2012

    NASA Technical Reports Server (NTRS)

    Ratcliff, J. T.; Gross, R. S.

    2013-01-01

    Independent Earth orientation measurements taken by the space-geodetic techniques of lunar and satellite laser ranging, very long baseline interferometry, and the Global Positioning System have been combined using a Kalman filter. The resulting combined Earth orientation series, SPACE2012, consists of values and uncertainties for Universal Time, polar motion, and their rates that span from September 28, 1976, to April 26, 2013, at daily intervals and is available in versions with epochs given at either midnight or noon. The space-geodetic measurements used to generate SPACE2012 have then been combined with optical astrometric measurements to form two additional combined Earth orientation series: (1) COMB2012, consisting of values and uncertainties for Universal Time, polar motion, and their rates that span from January 20, 1962, to April 26, 2013, at daily intervals and which are also available in versions with epochs given at either midnight or noon; and (2) POLE2012, consisting of values and uncertainties for polar motion and its rate that span from January 20, 1900, to May 22, 2013, at 30.4375-day intervals.

  9. Does Reducing the Duration from Symptom Onset to Recanalization Improve the Results of Intracranial Mechanical Thrombectomy in the Elderly?

    PubMed Central

    KOMATSUBARA, Koichiro; DEMBO, Tomohisa; SATO, Eishi; SASAMORI, Hiroki; TORII, Masataka; SHIOKAWA, Yoshiaki; HIRANO, Teruyuki

    2017-01-01

    Endovascular recanalization for acute major cerebral artery occlusion is effective within a short time after symptom onset. However, its efficacy in the elderly remains unknown. We assessed the efficacy of our comprehensive stroke center’s reduction of this time in 28 consecutive patients for elderly patients (defined as patients aged ≥75 years) with acute major cerebral artery occlusion treated with intravenous injection of tissue plasminogen activator, followed by thrombus retrieval by endovascular therapy. The patients were divided into groups according to whether they were treated before implementation of the time reduction measure (from January 2012 to May 2014) or after (from June 2014 to May 2015). The onset-to-door, onset-to-needle, onset-to-recanalization (O2R), door-to-image (D2I), door-to-needle (D2N), door-to-puncture (D2P), door-to-recanalization (D2R), and puncture-to-recanalization time intervals were compared between the two groups. There were 14 patients (including 8 elderly patients ≥80 years) before and 14 patients (including 10 elderly patients ≥80 years) after the time reduction measure. The mean duration of each of the following time intervals was significantly reduced after the time reduction measure (P < 0.05). To reduce the O2R time, the D2P time is the first time interval that can be reduced. At our center, conferences were regularly held to raise awareness among staff and make specific changes in the workflow, and overall time reduction was achieved. Similar results were obtained in elderly patients. PMID:28132961

  10. Wind measurements by electromagnetic probes

    NASA Technical Reports Server (NTRS)

    Susko, Michael

    1989-01-01

    The operation and performance characteristics of the Marshall Space Flight Center's Radar Wind Profiler, designed to provide measurement of the wind in the troposphere, are discussed. The Radar Wind Profiler uses a technology similar to that used in conventional Doppler radar systems, except the frequency is generally lower, antenna is larger, and dwell time is much longer. Its primary function is to monitor the vertical wind profile prior to launch of the Space Shuttle at more frequency intervals and nearer to launch time than is presently possible with the conventional balloon systems. A new wind profile will be obtained on the order of every 15 min based on an average of five wind profiles measured every 3 min at a height interval of 150 m to 20 km. The most significant features of the Radar Wind Profiler are the continuity in time and reliability.

  11. Feasibility of noninvasive fetal electrocardiographic monitoring in a clinical setting.

    PubMed

    Arya, Bhawna; Govindan, Rathinaswamy; Krishnan, Anita; Duplessis, Adre; Donofrio, Mary T

    2015-06-01

    Cardiac rhythm is an essential component of fetal cardiac evaluation. The Monica AN24 is a fetal heart rate monitor that may provide a quick, inexpensive modality for obtaining a noninvasive fetal electrocardiogram (fECG) in a clinical setting. The fECG device has the ability to acquire fECG signals and allow calculation of fetal cardiac time intervals between 16- and 42-week gestational age (GA). We aimed to demonstrate the feasibility of fECG acquisition in a busy fetal cardiology clinic using the Monica fetal heart rate monitor. This is a prospective observational pilot study of fECG acquired from fetuses referred for fetal echocardiography. Recordings were performed for 5-15 min. Maternal signals were attenuated and fECG averaged. fECG and fetal cardiac time intervals (PR, QRS, RR, and QT) were evaluated by two cardiologists independently and inter-observer reliability was assessed using intraclass coefficient (ICC). Sixty fECGs were collected from 50 mothers (mean GA 28.1 ± 6.1). Adequate signal-averaged waveforms were obtained in 20 studies with 259 cardiac cycles. Waveforms could not be obtained between 26 and 30 weeks. Fetal cardiac time intervals were measured and were reproducible for PR (ICC = 0.89; CI 0.77-0.94), QRS (ICC = 0.79; CI 0.51-0.91), and RR (ICC = 0.77; CI 0.53-0.88). QT ICC was poor due to suboptimal T-wave tracings. Acquisition of fECG and measurement of fetal cardiac time intervals is feasible in a clinical setting between 19- and 42-week GA, though tracings are difficult to obtain, especially between 26 and 30 weeks. There was high reliability in fetal cardiac time intervals measurements, except for QT. The device may be useful for assessing atrioventricular/intraventricular conduction in fetuses from 20 to 26 and >30 weeks. Techniques to improve signal acquisition, namely T-wave amplification, are ongoing.

  12. CMOS direct time interval measurement of long-lived luminescence lifetimes.

    PubMed

    Yao, Lei; Yung, Ka Yi; Cheung, Maurice C; Chodavarapu, Vamsy P; Bright, Frank V

    2011-01-01

    We describe a Complementary Metal-Oxide Semiconductor (CMOS) Direct Time Interval Measurement (DTIM) Integrated Circuit (IC) to detect the decay (fall) time of the luminescence emission when analyte-sensitive luminophores are excited with an optical pulse. The CMOS DTIM IC includes 14 × 14 phototransistor array, transimpedance amplifier, regulated gain amplifier, fall time detector, and time-to-digital convertor. We examined the DTIM system to measure the emission lifetime of oxygen-sensitive luminophores tris(4,7-diphenyl-1, 10-phenanthroline) ruthenium(II) ([Ru(dpp)(3)](2+)) encapsulated in sol-gel derived xerogel thin-films. The DTIM system fabricated using TSMC 0.35 μm process functions to detect lifetimes from 4 μs to 14.4 μs but can be tuned to detect longer lifetimes. The system provides 8-bit digital output proportional to lifetimes and consumes 4.5 mW of power with 3.3 V DC supply. The CMOS system provides a useful platform for the development of reliable, robust, and miniaturized optical chemical sensors.

  13. Optimal methods for fitting probability distributions to propagule retention time in studies of zoochorous dispersal.

    PubMed

    Viana, Duarte S; Santamaría, Luis; Figuerola, Jordi

    2016-02-01

    Propagule retention time is a key factor in determining propagule dispersal distance and the shape of "seed shadows". Propagules dispersed by animal vectors are either ingested and retained in the gut until defecation or attached externally to the body until detachment. Retention time is a continuous variable, but it is commonly measured at discrete time points, according to pre-established sampling time-intervals. Although parametric continuous distributions have been widely fitted to these interval-censored data, the performance of different fitting methods has not been evaluated. To investigate the performance of five different fitting methods, we fitted parametric probability distributions to typical discretized retention-time data with known distribution using as data-points either the lower, mid or upper bounds of sampling intervals, as well as the cumulative distribution of observed values (using either maximum likelihood or non-linear least squares for parameter estimation); then compared the estimated and original distributions to assess the accuracy of each method. We also assessed the robustness of these methods to variations in the sampling procedure (sample size and length of sampling time-intervals). Fittings to the cumulative distribution performed better for all types of parametric distributions (lognormal, gamma and Weibull distributions) and were more robust to variations in sample size and sampling time-intervals. These estimated distributions had negligible deviations of up to 0.045 in cumulative probability of retention times (according to the Kolmogorov-Smirnov statistic) in relation to original distributions from which propagule retention time was simulated, supporting the overall accuracy of this fitting method. In contrast, fitting the sampling-interval bounds resulted in greater deviations that ranged from 0.058 to 0.273 in cumulative probability of retention times, which may introduce considerable biases in parameter estimates. We recommend the use of cumulative probability to fit parametric probability distributions to propagule retention time, specifically using maximum likelihood for parameter estimation. Furthermore, the experimental design for an optimal characterization of unimodal propagule retention time should contemplate at least 500 recovered propagules and sampling time-intervals not larger than the time peak of propagule retrieval, except in the tail of the distribution where broader sampling time-intervals may also produce accurate fits.

  14. Semiparametric regression analysis of failure time data with dependent interval censoring.

    PubMed

    Chen, Chyong-Mei; Shen, Pao-Sheng

    2017-09-20

    Interval-censored failure-time data arise when subjects are examined or observed periodically such that the failure time of interest is not examined exactly but only known to be bracketed between two adjacent observation times. The commonly used approaches assume that the examination times and the failure time are independent or conditionally independent given covariates. In many practical applications, patients who are already in poor health or have a weak immune system before treatment usually tend to visit physicians more often after treatment than those with better health or immune system. In this situation, the visiting rate is positively correlated with the risk of failure due to the health status, which results in dependent interval-censored data. While some measurable factors affecting health status such as age, gender, and physical symptom can be included in the covariates, some health-related latent variables cannot be observed or measured. To deal with dependent interval censoring involving unobserved latent variable, we characterize the visiting/examination process as recurrent event process and propose a joint frailty model to account for the association of the failure time and visiting process. A shared gamma frailty is incorporated into the Cox model and proportional intensity model for the failure time and visiting process, respectively, in a multiplicative way. We propose a semiparametric maximum likelihood approach for estimating model parameters and show the asymptotic properties, including consistency and weak convergence. Extensive simulation studies are conducted and a data set of bladder cancer is analyzed for illustrative purposes. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Extracting Hot spots of Topics from Time Stamped Documents

    PubMed Central

    Chen, Wei; Chundi, Parvathi

    2011-01-01

    Identifying time periods with a burst of activities related to a topic has been an important problem in analyzing time-stamped documents. In this paper, we propose an approach to extract a hot spot of a given topic in a time-stamped document set. Topics can be basic, containing a simple list of keywords, or complex. Logical relationships such as and, or, and not are used to build complex topics from basic topics. A concept of presence measure of a topic based on fuzzy set theory is introduced to compute the amount of information related to the topic in the document set. Each interval in the time period of the document set is associated with a numeric value which we call the discrepancy score. A high discrepancy score indicates that the documents in the time interval are more focused on the topic than those outside of the time interval. A hot spot of a given topic is defined as a time interval with the highest discrepancy score. We first describe a naive implementation for extracting hot spots. We then construct an algorithm called EHE (Efficient Hot Spot Extraction) using several efficient strategies to improve performance. We also introduce the notion of a topic DAG to facilitate an efficient computation of presence measures of complex topics. The proposed approach is illustrated by several experiments on a subset of the TDT-Pilot Corpus and DBLP conference data set. The experiments show that the proposed EHE algorithm significantly outperforms the naive one, and the extracted hot spots of given topics are meaningful. PMID:21765568

  16. Effect of temporal sampling and timing for soil moisture measurements at field scale

    NASA Astrophysics Data System (ADS)

    Snapir, B.; Hobbs, S.

    2012-04-01

    Estimating soil moisture at field scale is valuable for various applications such as irrigation scheduling in cultivated watersheds, flood and drought prediction, waterborne disease spread assessment, or even determination of mobility with lightweight vehicles. Synthetic aperture radar on satellites in low Earth orbit can provide fine resolution images with a repeat time of a few days. For an Earth observing satellite, the choice of the orbit is driven in particular by the frequency of measurements required to meet a certain accuracy in retrieving the parameters of interest. For a given target, having only one image every week may not enable to capture the full dynamic range of soil moisture - soil moisture can change significantly within a day when rainfall occurs. Hence this study focuses on the effect of temporal sampling and timing of measurements in terms of error on the retrieved signal. All the analyses are based on in situ measurements of soil moisture (acquired every 30 min) from the OzNet Hydrological Monitoring Network in Australia for different fields over several years. The first study concerns sampling frequency. Measurements at different frequencies were simulated by sub-sampling the original data. Linear interpolation was used to estimate the missing intermediate values, and then this time series was compared to the original. The difference between these two signals is computed for different levels of sub-sampling. Results show that the error increases linearly when the interval is less than 1 day. For intervals longer than a day, a sinusoidal component appears on top of the linear growth due to the diurnal variation of surface soil moisture. Thus, for example, the error with measurements every 4.5 days can be slightly less than the error with measurements every 2 days. Next, for a given sampling interval, this study evaluated the effect of the time during the day at which measurements are made. Of course when measurements are very frequent the time of acquisition does not matter, but when few measurements are available (sampling interval > 1 day), the time of acquisition can be important. It is shown that with daily measurements the error can double depending on the time of acquisition. This result is very sensitive to the phase of the sinusoidal variation of soil moisture. For example, in autumn for a given field with soil moisture ranging from 7.08% to 11.44% (mean and standard deviation being respectively 8.68% and 0.74%), daily measurements at 2 pm lead to a mean error of 0.47% v/v, while daily measurements at 9 am/pm produce a mean error of 0.24% v/v. The minimum of the sinusoid occurs every afternoon around 2 pm, after interpolation, measurements acquired at this time underestimate soil moisture, whereas measurements around 9 am/pm correspond to nodes of the sinusoid, hence they represent the average soil moisture. These results concerning the frequency and the timing of measurements can potentially drive the schedule of satellite image acquisition over some fields.

  17. Integrated Doppler Correction to TWSTFT Using Round-Trip Measurement

    DTIC Science & Technology

    2010-11-01

    42 nd Annual Precise Time and Time Interval (PTTI) Meeting 251 INTEGRATED DOPPLER CORRECTION TO TWSTFT USING ROUND-TRIP MEASUREMENT Yi...Frequency Transfer ( TWSTFT ) data. It is necessary to correct the diurnal variation for comparing the time-scale difference. We focus on the up-/downlink...delay difference caused by satellite motion. In this paper, we propose to correct the TWSTFT data by using round-trip delay measurement. There are

  18. Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

    PubMed

    Ding, Xiaorong; Yan, Bryan P; Zhang, Yuan-Ting; Liu, Jing; Zhao, Ni; Tsang, Hon Ki

    2017-09-14

    Cuffless technique enables continuous blood pressure (BP) measurement in an unobtrusive manner, and thus has the potential to revolutionize the conventional cuff-based approaches. This study extends the pulse transit time (PTT) based cuffless BP measurement method by introducing a new indicator - the photoplethysmogram (PPG) intensity ratio (PIR). The performance of the models with PTT and PIR was comprehensively evaluated in comparison with six models that are based on sole PTT. The validation conducted on 33 subjects with and without hypertension, at rest and under various maneuvers with induced BP changes, and over an extended calibration interval, respectively. The results showed that, comparing to the PTT models, the proposed methods achieved better accuracy on each subject group at rest state and over 24 hours calibration interval. Although the BP estimation errors under dynamic maneuvers and over extended calibration interval were significantly increased for all methods, the proposed methods still outperformed the compared methods in the latter situation. These findings suggest that additional BP-related indicator other than PTT has added value for improving the accuracy of cuffless BP measurement. This study also offers insights into future research in cuffless BP measurement for tracking dynamic BP changes and over extended periods of time.

  19. The effects of time compositing on obtaining clear-sky coverage for infrared temperature and moisture profiling from geosynchronous orbit

    NASA Technical Reports Server (NTRS)

    Shenk, William E.; Hope, William A.

    1994-01-01

    The impact of time compositing on infrared profiling from geosynchronous orbit was evaluated for two convective outbreak cases. Time compositing is the accumulation of the data from several successive images taken at short intervals to provide a single field of measurements with the temporal resolution equal to the time to take all of the images. This is especially effective when the variability of the measurements is slow compared to the image interval. Time compositing should be able to reduce the interference of clouds for infrared measurments since clouds move and change. The convective outbreak cases were on 4 and 21 May 1990 over the eastern Midwest and southeastern United States, respectively. Geostationary Operational Environmental (GOES) Satellite imagery was used to outline clear areas at hourly intervals by two independent analysts. Time compositing was done every 3 h (1330-1530 UTC; 1630-1830 UTC) and over the full 5-h period. For both cases, a significant increase in coverage was measured with each 3-h compositing (about a factor of 2) and a further increase over the full period (approximately a factor of 3). The increase was especially useful in areas of broken cloud cover where large gaps between potential profiling areas on each image were reduced. To provide information on measurement variability over local areas, the regions where the clear-area analyses were done were subdivided into 0.5 deg latitude-longitude boxes, and if some portion of each box was clear, it was assumed that at least one profile could be obtained within the box. In the largest clear areas, at least some portion was clear every hour. Even in the cloudier regions, multiple clear looks possible during the entire period.

  20. The Role of Patients and Providers in the Timing of Follow-up Visits

    PubMed Central

    Welch, H Gilbert; Chapko, Michael K; James, Kenneth E; Schwartz, Lisa M; Woloshin, Steven

    1999-01-01

    OBJECTIVE Although the decision about how frequently to see outpatients has a direct impact on a provider’s workload and may impact health care costs, revisit intervals have rarely been a topic of investigation. To begin to understand what factors are correlated with this decision, we examined baseline data from a Department of Veterans Affairs (VA) Cooperative Study designed to evaluate telephone care. DESIGN Observational study based on extensive patient data collected during enrollment into the randomized trial. Providers were required to recommend a revisit interval (e.g., “return visit in 3 months”) for each patient before randomization, under the assumption that the patient would be receiving clinic visits as usual. POPULATON/SETTING Five hundred seventy-one patients over age 55 cared for by one of the 30 providers working in three VA general medical clinics. Patients for whom immediate follow-up (≤2 weeks) was recommended were excluded. MEASUREMENTS Mean revisit interval was adjusted for patient factors using a regression model that accounted for patients being nested within providers and providers being nested within sites. Four patient-level variable blocks (illness burden–patient, travel time, illness burden–physician, and prior utilization) were sequentially entered into a linear model to determine their role in explaining the variance in revisit intervals. Physician identity was also entered after four blocks. MAIN RESULTS Recommended revisit intervals ranged from 1 month to over 1 year with the most common recommended intervals being 2, 3, or 6 months. About 10% of the variance in revisit interval was explained by illness measures independent of provider (e.g., general health perception) and travel time. Adding other illness measures (e.g., diagnoses, medications) and prior utilization (e.g., clinic visits) doubled the variance explained (R2= .21). Finally, the identification of individual provider doubled the explained variance again (R2= .45). After adjusting for patient factors, the average revisit interval for individual providers ranged from 8 to 26 weeks (8 to 19 weeks when restricted to the 16 staff physicians). There were also substantial differences across the three sites (adjusted means: 14, 17, and 11 weeks). CONCLUSIONS Even after adjusting for a detailed array of patient-level data, primary care providers have different practice styles regarding the timing of return visits. These may, in turn, reflect the local “culture” in which they practice. How many patients providers are able to care for may be determined by the providers’ inclinations toward the timing of follow-up visits. PMID:10203634

  1. High-Speed, capacitance-based tip clearance sensing

    NASA Astrophysics Data System (ADS)

    Haase, W. C.; Haase, Z. S.

    This paper discusses recent advances in tip clearance measurement systems for turbine engines using capacitive probes. Real time measurements of individual blade pulses are generated using wideband signal processing providing 3 dB bandwidths of typically 5 MHz. Subsequent mixed-signal processing circuitry provide real-time measurements of maximum, minimum, and average clearance with latencies of one blade-to-blade time interval. Both guarded and unguarded probe configurations are possible with the system. Calibration techniques provide high accuracy measurements.

  2. Motor Synchronization in Patients With Schizophrenia: Preserved Time Representation With Abnormalities in Predictive Timing.

    PubMed

    Wilquin, Hélène; Delevoye-Turrell, Yvonne; Dione, Mariama; Giersch, Anne

    2018-01-01

    Objective: Basic temporal dysfunctions have been described in patients with schizophrenia, which may impact their ability to connect and synchronize with the outer world. The present study was conducted with the aim to distinguish between interval timing and synchronization difficulties and more generally the spatial-temporal organization disturbances for voluntary actions. A new sensorimotor synchronization task was developed to test these abilities. Method: Twenty-four chronic schizophrenia patients matched with 27 controls performed a spatial-tapping task in which finger taps were to be produced in synchrony with a regular metronome to six visual targets presented around a virtual circle on a tactile screen. Isochronous (time intervals of 500 ms) and non-isochronous auditory sequences (alternated time intervals of 300/600 ms) were presented. The capacity to produce time intervals accurately versus the ability to synchronize own actions (tap) with external events (tone) were measured. Results: Patients with schizophrenia were able to produce the tapping patterns of both isochronous and non-isochronous auditory sequences as accurately as controls producing inter-response intervals close to the expected interval of 500 and 900 ms, respectively. However, the synchronization performances revealed significantly more positive asynchrony means (but similar variances) in the patient group than in the control group for both types of auditory sequences. Conclusion: The patterns of results suggest that patients with schizophrenia are able to perceive and produce both simple and complex sequences of time intervals but are impaired in the ability to synchronize their actions with external events. These findings suggest a specific deficit in predictive timing, which may be at the core of early symptoms previously described in schizophrenia.

  3. Increasing Recovery Time Between Injuries Improves Cognitive Outcome After Repetitive Mild Concussive Brain Injuries in Mice

    PubMed Central

    Zhang, Jimmy; Mannix, Rebekah; Whalen, Michael J.

    2012-01-01

    Abstract BACKGROUND: Although previous evidence suggests that the cognitive effects of concussions are cumulative, the effect of time interval between repeat concussions is largely unknown. OBJECTIVE: To determine the effect of time interval between repeat concussions on the cognitive function of mice. METHODS: We used a weight-drop model of concussion to subject anesthetized mice to 1, 3, 5, or 10 concussions, each a day apart. Additional mice were subjected to 5 concussions at varying time intervals: daily, weekly, and monthly. Morris water maze performance was measured 24 hours, 1 month, and 1 year after final injury. RESULTS: After 1 concussion, injured and sham-injured mice performed similarly in the Morris water maze. As the number of concussions increased, injured mice performed worse than sham-injured mice. Mice sustaining 5 concussions either 1 day or 1 week apart performed worse than sham-injured mice. When 5 concussions were delivered at 1-month time intervals, no difference in Morris water maze performance was observed between injured and sham-injured mice. After a 1-month recovery period, mice that sustained 5 concussions at daily and weekly time intervals continued to perform worse than sham-injured mice. One year after the final injury, mice sustaining 5 concussions at a daily time interval still performed worse than sham-injured mice. CONCLUSION: When delivered within a period of vulnerability, the cognitive effects of multiple concussions are cumulative, persistent, and may be permanent. Increasing the time interval between concussions attenuates the effects on cognition. When multiple concussions are sustained by mice daily, the effects on cognition are long term. PMID:22743360

  4. High resolution in situ ultrasonic corrosion monitor

    DOEpatents

    Grossman, R.J.

    1984-01-10

    An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.

  5. High resolution in situ ultrasonic corrosion monitor

    DOEpatents

    Grossman, Robert J.

    1985-01-01

    An ultrasonic corrosion monitor is provided which produces an in situ measurement of the amount of corrosion of a monitoring zone or zones of an elongate probe placed in the corrosive environment. A monitoring zone is preferably formed between the end of the probe and the junction of the zone with a lead-in portion of the probe. Ultrasonic pulses are applied to the probe and a determination made of the time interval between pulses reflected from the end of the probe and the junction referred to, both when the probe is uncorroded and while it is corroding. Corresponding electrical signals are produced and a value for the normalized transit time delay derived from these time interval measurements is used to calculate the amount of corrosion.

  6. Quantitative imaging biomarkers: Effect of sample size and bias on confidence interval coverage.

    PubMed

    Obuchowski, Nancy A; Bullen, Jennifer

    2017-01-01

    Introduction Quantitative imaging biomarkers (QIBs) are being increasingly used in medical practice and clinical trials. An essential first step in the adoption of a quantitative imaging biomarker is the characterization of its technical performance, i.e. precision and bias, through one or more performance studies. Then, given the technical performance, a confidence interval for a new patient's true biomarker value can be constructed. Estimating bias and precision can be problematic because rarely are both estimated in the same study, precision studies are usually quite small, and bias cannot be measured when there is no reference standard. Methods A Monte Carlo simulation study was conducted to assess factors affecting nominal coverage of confidence intervals for a new patient's quantitative imaging biomarker measurement and for change in the quantitative imaging biomarker over time. Factors considered include sample size for estimating bias and precision, effect of fixed and non-proportional bias, clustered data, and absence of a reference standard. Results Technical performance studies of a quantitative imaging biomarker should include at least 35 test-retest subjects to estimate precision and 65 cases to estimate bias. Confidence intervals for a new patient's quantitative imaging biomarker measurement constructed under the no-bias assumption provide nominal coverage as long as the fixed bias is <12%. For confidence intervals of the true change over time, linearity must hold and the slope of the regression of the measurements vs. true values should be between 0.95 and 1.05. The regression slope can be assessed adequately as long as fixed multiples of the measurand can be generated. Even small non-proportional bias greatly reduces confidence interval coverage. Multiple lesions in the same subject can be treated as independent when estimating precision. Conclusion Technical performance studies of quantitative imaging biomarkers require moderate sample sizes in order to provide robust estimates of bias and precision for constructing confidence intervals for new patients. Assumptions of linearity and non-proportional bias should be assessed thoroughly.

  7. Dynamic MRI for distinguishing high-flow from low-flow peripheral vascular malformations.

    PubMed

    Ohgiya, Yoshimitsu; Hashimoto, Toshi; Gokan, Takehiko; Watanabe, Shouji; Kuroda, Masayoshi; Hirose, Masanori; Matsui, Seishi; Nobusawa, Hiroshi; Kitanosono, Takashi; Munechika, Hirotsugu

    2005-11-01

    The purpose of our study was to assess the usefulness of dynamic MRI in distinguishing high-flow vascular malformations from low-flow vascular malformations, which do not need angiography for treatment. Between September 2001 and January 2003, 16 patients who underwent conventional and dynamic MRI had peripheral vascular malformations (six high- and 10 low-flow). The temporal resolution of dynamic MRI was 5 sec. Time intervals between beginning of enhancement of an arterial branch in the vicinity of a lesion in the same slice and the onset of enhancement in the lesion were calculated. We defined these time intervals as "artery-lesion enhancement time." Time intervals between the onset of enhancement in the lesion and the time of the maximal percentage of enhancement above baseline of the lesion within 120 sec were measured. We defined these time intervals as "contrast rise time" of the lesion. Diagnosis of the peripheral vascular malformations was based on angiographic or venographic findings. The mean artery-lesion enhancement time of the high-flow vascular malformations (3.3 sec [range, 0-5 sec]) was significantly shorter than that of the low-flow vascular malformations (8.8 sec [range, 0-20 sec]) (Mann-Whitney test, p < 0.05). The mean maximal lesion enhancement time of the high-flow vascular malformations (5.8 sec [range, 5-10 sec]) was significantly shorter than that of the low-flow vascular malformations (88.4 sec [range, 50-100 sec]) (Mann-Whitney test, p < 0.01). Dynamic MRI is useful for distinguishing high-flow from low-flow vascular malformations, especially when the contrast rise time of the lesion is measured.

  8. Assessment of identity during adolescence using daily diary methods: Measurement invariance across time and sex.

    PubMed

    Becht, Andrik I; Branje, Susan J T; Vollebergh, Wilma A M; Maciejewski, Dominique F; van Lier, Pol A C; Koot, Hans M; Denissen, Jaap J A; Meeus, Wim H J

    2016-06-01

    The aim of this study was to assess measurement invariance of adolescents' daily reports on identity across time and sex. Adolescents (N = 497; mean age = 13.32 years at Time 1, 56.7% boys) from the general population reported on their identity commitments, exploration in depth and reconsideration on a daily basis for 3 weeks within 1 year across 5 years. We used the single-item version of the Utrecht Management of Identity Commitments Scale (UMICS; Klimstra et al., 2010), a broad measure of identity-formation processes covering both interpersonal and educational identity domains. This study tested configural, metric, scalar, and strict measurement invariance across days within weeks, across sex, across weeks within years, and across years. Results indicated that daily diary reports show strict measurement invariance across days, across weeks within years, across years, and across boys and girls. These results support the use of daily diary methods to assess identity at various time intervals ranging from days to years and across sex. Results are discussed with regard to future implications to study identity processes, both on smaller and larger time intervals. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Effect of Variations in IRU Integration Time Interval On Accuracy of Aqua Attitude Estimation

    NASA Technical Reports Server (NTRS)

    Natanson, G. A.; Tracewell, Dave

    2003-01-01

    During Aqua launch support, attitude analysts noticed several anomalies in Onboard Computer (OBC) rates and in rates computed by the ground Attitude Determination System (ADS). These included: 1) periodic jumps in the OBC pitch rate every 2 minutes; 2) spikes in ADS pitch rate every 4 minutes; 3) close agreement between pitch rates computed by ADS and those derived from telemetered OBC quaternions (in contrast to the step-wise pattern observed for telemetered OBC rates); 4) spikes of +/- 10 milliseconds in telemetered IRU integration time every 4 minutes (despite the fact that telemetered time tags of any two sequential IRU measurements were always 1 second apart from each other). An analysis presented in the paper explains this anomalous behavior by a small average offset of about 0.5 +/- 0.05 microsec in the time interval between two sequential accumulated angle measurements. It is shown that errors in the estimated pitch angle due to neglecting the aforementioned variations in the integration time interval by the OBC is within +/- 2 arcseconds. Ground attitude solutions are found to be accurate enough to see the effect of the variations on the accuracy of the estimated pitch angle.

  10. Effects Of Reinforcement History On Response Rate And Response Pattern In Periodic Reinforcement

    PubMed Central

    López, Florente; Menez, Marina

    2005-01-01

    Several researchers have suggested that conditioning history may have long-term effects on fixed-interval performances of rats. To test this idea and to identify possible factors involved in temporal control development, groups of rats initially were exposed to different reinforcement schedules: continuous, fixed-time, and random-interval. Afterwards, half of the rats in each group were studied on a fixed-interval 30-s schedule of reinforcement and the other half on a fixed-interval 90-s schedule of reinforcement. No evidence of long-term effects attributable to conditioning history on either response output or response patterning was found; history effects were transitory. Different tendencies in trajectory across sessions were observed for measures of early and late responding within the interreinforcer interval, suggesting that temporal control is the result of two separate processes: one involved in response output and the other in time allocation of responding and not responding. PMID:16047607

  11. Probing interval timing with scalp-recorded electroencephalography (EEG).

    PubMed

    Ng, Kwun Kei; Penney, Trevor B

    2014-01-01

    Humans, and other animals, are able to easily learn the durations of events and the temporal relationships among them in spite of the absence of a dedicated sensory organ for time. This chapter summarizes the investigation of timing and time perception using scalp-recorded electroencephalography (EEG), a non-invasive technique that measures brain electrical potentials on a millisecond time scale. Over the past several decades, much has been learned about interval timing through the examination of the characteristic features of averaged EEG signals (i.e., event-related potentials, ERPs) elicited in timing paradigms. For example, the mismatch negativity (MMN) and omission potential (OP) have been used to study implicit and explicit timing, respectively, the P300 has been used to investigate temporal memory updating, and the contingent negative variation (CNV) has been used as an index of temporal decision making. In sum, EEG measures provide biomarkers of temporal processing that allow researchers to probe the cognitive and neural substrates underlying time perception.

  12. Real-time hydraulic interval state estimation for water transport networks: a case study

    NASA Astrophysics Data System (ADS)

    Vrachimis, Stelios G.; Eliades, Demetrios G.; Polycarpou, Marios M.

    2018-03-01

    Hydraulic state estimation in water distribution networks is the task of estimating water flows and pressures in the pipes and nodes of the network based on some sensor measurements. This requires a model of the network as well as knowledge of demand outflow and tank water levels. Due to modeling and measurement uncertainty, standard state estimation may result in inaccurate hydraulic estimates without any measure of the estimation error. This paper describes a methodology for generating hydraulic state bounding estimates based on interval bounds on the parametric and measurement uncertainties. The estimation error bounds provided by this method can be applied to determine the existence of unaccounted-for water in water distribution networks. As a case study, the method is applied to a modified transport network in Cyprus, using actual data in real time.

  13. Assessing the Impact of Different Measurement Time Intervals on Observed Long-Term Wind Speed Trends

    NASA Astrophysics Data System (ADS)

    Azorin-Molina, C.; Vicente-Serrano, S. M.; McVicar, T.; Jerez, S.; Revuelto, J.; López Moreno, J. I.

    2014-12-01

    During the last two decades climate studies have reported a tendency toward a decline in measured near-surface wind speed in some regions of Europe, North America, Asia and Australia. This weakening in observed wind speed has been recently termed "global stilling", showing a worldwide average trend of -0.140 m s-1 dec-1 during last 50-years. The precise cause of the "global stilling" remains largely uncertain and has been hypothetically attributed to several factors, mainly related to: (i) an increasing surface roughness (i.e. forest growth, land use changes, and urbanization); (ii) a slowdown in large-scale atmospheric circulation; (iii) instrumental drifts and technological improvements, maintenance, and shifts in measurements sites and calibration issues; (iv) sunlight dimming due to air pollution; and (v) astronomical changes. This study proposed a novel investigation aimed at analyzing how different measurement time intervals used to calculate a wind speed series can affect the sign and magnitude of long-term wind speed trends. For instance, National Weather Services across the globe estimate daily average wind speed using different time intervals and formulae that may affect the trend results. Firstly, we carried out a comprehensive review of wind studies reporting the sign and magnitude of wind speed trend and the sampling intervals used. Secondly, we analyzed near-surface wind speed trends recorded at 59 land-based stations across Spain comparing monthly mean wind speed series obtained from: (a) daily mean wind speed data averaged from standard 10-min mean observations at 0000, 0700, 1300 and 1800 UTC; and (b) average wind speed of 24 hourly measurements (i.e., wind run measurements) from 0000 to 2400 UTC. Thirdly and finally, we quantified the impact of anemometer drift (i.e. bearing malfunction) by presenting preliminary results (1-year of paired measurements) from a comparison of one new anemometer sensor against one malfunctioned anenometer sensor due to old bearings.

  14. Intrarater test-retest reliability of static and dynamic stability indexes measurement using the Biodex Stability System during unilateral stance.

    PubMed

    Arifin, Nooranida; Abu Osman, Noor Azuan; Wan Abas, Wan Abu Bakar

    2014-04-01

    The measurements of postural balance often involve measurement error, which affects the analysis and interpretation of the outcomes. In most of the existing clinical rehabilitation research, the ability to produce reliable measures is a prerequisite for an accurate assessment of an intervention after a period of time. Although clinical balance assessment has been performed in previous study, none has determined the intrarater test-retest reliability of static and dynamic stability indexes during dominant single stance. In this study, one rater examined 20 healthy university students (female=12, male=8) in two sessions separated by 7 day intervals. Three stability indexes--the overall stability index (OSI), anterior/posterior stability index (APSI), and medial/ lateral stability index (MLSI) in static and dynamic conditions--were measured during single dominant stance. Intraclass correlation coefficient (ICC), standard error measurement (SEM) and 95% confidence interval (95% CI) were calculated. Test-retest ICCs for OSI, APSI, and MLSI were 0.85, 0.78, and 0.84 during static condition and were 0.77, 0.77, and 0.65 during dynamic condition, respectively. We concluded that the postural stability assessment using Biodex stability system demonstrates good-to-excellent test-retest reliability over a 1 week time interval.

  15. Comparison of Observational Methods and Their Relation to Ratings of Engagement in Young Children

    ERIC Educational Resources Information Center

    Wood, Brenna K.; Hojnoski, Robin L.; Laracy, Seth D.; Olson, Christopher L.

    2016-01-01

    Although, collectively, results of earlier direct observation studies suggest momentary time sampling (MTS) may offer certain technical advantages over whole-interval (WIR) and partial-interval (PIR) recording, no study has compared these methods for measuring engagement in young children in naturalistic environments. This study compared direct…

  16. The Lambert-Beer law in time domain form and its application.

    PubMed

    Mosorov, Volodymyr

    2017-10-01

    The majority of current radioisotope gauges utilize measurements of intensity for a chosen sampling time interval using a detector. Such an approach has several disadvantages: temporal resolution of the gauge is fixed and the accuracy of the measurements is not the same for different count rate. The solution can be the use of a stronger radioactive source, but it will be conflicted with ALARA (As Low As Reasonably Achievable) principle. Therefore, the article presents an alternative approach which is based on modified Lambert-Beer law. The basis of the approach is the registration of time intervals instead of the registration of counts. It allows to increase the temporal resolution of a gauge without the necessity of using a stronger radioactive source and the accuracy of the measurements will not depend on count rate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Synchronization in monkey visual cortex analyzed with an information-theoretic measure

    NASA Astrophysics Data System (ADS)

    Manyakov, Nikolay V.; Van Hulle, Marc M.

    2008-09-01

    We apply an information-theoretic measure for phase synchrony to local field potentials recorded with a multi-electrode array implanted in area V4 of the monkey visual cortex during a reinforcement pairing experiment. We show for the first time that (1) the phase synchrony is significantly higher for the rewarded stimulus than the unrewarded one, after training the monkey; (2) just after the stimuli reversal, the difference in phase synchronization is due to the stimuli, not the reward; (3) the difference between reward and no reward is most clear in two disconnected time intervals between stimuli onset and the expected delivery of the reward; and (4) synchronous activity appears in waves running over the array, and their timing correlates well with the time intervals where the difference between reward and no reward is most prominent.

  18. Multichannel Spectrometer of Time Distribution

    NASA Astrophysics Data System (ADS)

    Akindinova, E. V.; Babenko, A. G.; Vakhtel, V. M.; Evseev, N. A.; Rabotkin, V. A.; Kharitonova, D. D.

    2015-06-01

    For research and control of characteristics of radiation fluxes, radioactive sources in particular, for example, in paper [1], a spectrometer and methods of data measurement and processing based on the multichannel counter of time intervals of accident events appearance (impulses of particle detector) MC-2A (SPC "ASPECT") were created. The spectrometer has four independent channels of registration of time intervals of impulses appearance and correspondent amplitude and spectrometric channels for control along the energy spectra of the operation stationarity of paths of each of the channels from the detector to the amplifier. The registration of alpha-radiation is carried out by the semiconductor detectors with energy resolution of 16-30 keV. Using a spectrometer there have been taken measurements of oscillations of alpha-radiation 239-Pu flux intensity with a subsequent autocorrelative statistical analysis of the time series of readings.

  19. Experimental and numerical investigation of low-drag intervals in turbulent boundary layer

    NASA Astrophysics Data System (ADS)

    Park, Jae Sung; Ryu, Sangjin; Lee, Jin

    2017-11-01

    It has been widely investigated that there is a substantial intermittency between high and low drag states in wall-bounded shear flows. Recent experimental and computational studies in a turbulent channel flow have identified low-drag time intervals based on wall shear stress measurements. These intervals are a weak turbulence state characterized by low-speed streaks and weak streamwise vortices. In this study, the spatiotemporal dynamics of low-drag intervals in a turbulent boundary layer is investigated using experiments and simulations. The low-drag intervals are monitored based on the wall shear stress measurement. We show that near the wall conditionally-sampled mean velocity profiles during low-drag intervals closely approach that of a low-drag nonlinear traveling wave solution as well as that of the so-called maximum drag reduction asymptote. This observation is consistent with the channel flow studies. Interestingly, the large spatial stretching of the streak is very evident in the wall-normal direction during low-drag intervals. Lastly, a possible connection between the mean velocity profile during the low-drag intervals and the Blasius profile will be discussed. This work was supported by startup funds from the University of Nebraska-Lincoln.

  20. Investigating the correlation between paediatric stride interval persistence and gross energy expenditure.

    PubMed

    Fairley, Jillian A; Sejdić, Ervin; Chau, Tom

    2010-02-26

    Stride interval persistence, a term used to describe the correlation structure of stride interval time series, is thought to provide insight into neuromotor control, though its exact clinical meaning has not yet been realized. Since human locomotion is shaped by energy efficient movements, it has been hypothesized that stride interval dynamics and energy expenditure may be inherently tied, both having demonstrated similar sensitivities to age, disease, and pace-constrained walking. This study tested for correlations between stride interval persistence and measures of energy expenditure including mass-specific gross oxygen consumption per minute (VO₂), mass-specific gross oxygen cost per meter (VO₂) and heart rate (HR). Metabolic and stride interval data were collected from 30 asymptomatic children who completed one 10-minute walking trial under each of the following conditions: (i) overground walking, (ii) hands-free treadmill walking, and (iii) handrail-supported treadmill walking. Stride interval persistence was not significantly correlated with (p > 0.32), VO₂ (p > 0.18) or HR (p > 0.56). No simple linear dependence exists between stride interval persistence and measures of gross energy expenditure in asymptomatic children when walking overground and on a treadmill.

  1. Is walking a random walk? Evidence for long-range correlations in stride interval of human gait

    NASA Technical Reports Server (NTRS)

    Hausdorff, Jeffrey M.; Peng, C.-K.; Ladin, Zvi; Wei, Jeanne Y.; Goldberger, Ary L.

    1995-01-01

    Complex fluctuation of unknown origin appear in the normal gait pattern. These fluctuations might be described as being (1) uncorrelated white noise, (2) short-range correlations, or (3) long-range correlations with power-law scaling. To test these possibilities, the stride interval of 10 healthy young men was measured as they walked for 9 min at their usual rate. From these time series we calculated scaling indexes by using a modified random walk analysis and power spectral analysis. Both indexes indicated the presence of long-range self-similar correlations extending over hundreds of steps; the stride interval at any time depended on the stride interval at remote previous times, and this dependence decayed in a scale-free (fractallike) power-law fashion. These scaling indexes were significantly different from those obtained after random shuffling of the original time series, indicating the importance of the sequential ordering of the stride interval. We demonstrate that conventional models of gait generation fail to reproduce the observed scaling behavior and introduce a new type of central pattern generator model that sucessfully accounts for the experimentally observed long-range correlations.

  2. Nonlogarithmic magnetization relaxation at the initial time intervals and magnetic field dependence of the flux creep rate in Bi2Sr2Ca(sub I)Cu2Ox single crystals

    NASA Technical Reports Server (NTRS)

    Moshchalcov, V. V.; Zhukov, A. A.; Kuznetzov, V. D.; Metlushko, V. V.; Leonyuk, L. I.

    1990-01-01

    At the initial time intervals, preceding the thermally activated flux creep regime, fast nonlogarithmic relaxation is found. The fully magnetic moment Pm(t) relaxation curve is shown. The magnetic measurements were made using SQUID-magnetometer. Two different relaxation regimes exist. The nonlogarithmic relaxation for the initial time intervals may be related to the viscous Abrikosov vortices flow with j is greater than j(sub c) for high enough temperature T and magnetic field induction B. This assumption correlates with Pm(t) measurements. The characteristic time t(sub O) separating two different relaxation regimes decreases as temperature and magnetic field are lowered. The logarithmic magnetization relaxation curves Pm(t) for fixed temperature and different external magnetic field inductions B are given. The relaxation rate dependence on magnetic field, R(B) = dPm(B, T sub O)/d(1nt) has a sharp maximum which is similar to that found for R(T) temperature dependences. The maximum shifts to lower fields as temperature goes up. The observed sharp maximum is related to a topological transition in shielding critical current distribution and, consequently, in Abrikosov vortices density. The nonlogarithmic magnetization relaxation for the initial time intervals is found. This fast relaxation has almost an exponentional character. The sharp relaxation rate R(B) maximum is observed. This maximum corresponds to a topological transition in Abrikosov vortices distribution.

  3. Effects of psilocybin on time perception and temporal control of behaviour in humans.

    PubMed

    Wittmann, Marc; Carter, Olivia; Hasler, Felix; Cahn, B Rael; Grimberg, Ulrike; Spring, Philipp; Hell, Daniel; Flohr, Hans; Vollenweider, Franz X

    2007-01-01

    Hallucinogenic psilocybin is known to alter the subjective experience of time. However, there is no study that systematically investigated objective measures of time perception under psilocybin. Therefore, we studied dose-dependent effects of the serotonin (5-HT)2A/1A receptor agonist psilocybin (4-phosphoryloxy-N, N-dimethyltryptamine) on temporal processing, employing tasks of temporal reproduction, sensorimotor synchronization and tapping tempo. To control for cognitive and subjective changes, we assessed spatial working memory and conscious experience. Twelve healthy human volunteers were tested under placebo, medium (115 microg/kg), and high (250 microg/kg) dose conditions, in a double-blind experimental design. Psilocybin was found to significantly impair subjects' ability to (1) reproduce interval durations longer than 2.5 sec, (2) to synchronize to inter-beat intervals longer than 2 sec and (3) caused subjects to be slower in their preferred tapping rate. These objective effects on timing performance were accompanied by working-memory deficits and subjective changes in conscious state, namely increased reports of 'depersonalization' and 'derealization' phenomena including disturbances in subjective 'time sense.' Our study is the first to systematically assess the impact of psilocybin on timing performance on standardized measures of temporal processing. Results indicate that the serotonin system is selectively involved in duration processing of intervals longer than 2 to 3 seconds and in the voluntary control of the speed of movement. We speculate that psilocybin's selective disruption of longer intervals is likely to be a product of interactions with cognitive dimensions of temporal processing -presumably via 5-HT2A receptor stimulation.

  4. Dating of Early Subdural Haematoma: A Correlative Clinico-Radiological Study

    PubMed Central

    Rao, Murali Gundu; Khandelwal, Niranjan; Sharma, Suresh Kumar

    2016-01-01

    Introduction Determination of post-traumatic interval remains one of the foremost important goals of any forensic investigation related to human crimes. The estimation of time since injury in cases of subdural haemorrhage has been studied only by a few investigators on the histological and radiological front. Aim The purpose of this study was to determine the post-traumatic interval of Subdural Haemorrhage (SDH) based on Hounsfield Unit measurements (HU) on Computed Tomography (CT) in surviving victims of head injury. Materials and Methods The study included a total of 100 cases of closed head injury with subdural haemorrhage. The Post-traumatic Time Interval (PTI) varied from 0.5 hours to a maximum of 249 hours, with a mean of 54.2 hours. Results Statistically significant results were obtained between the HU measurements of the SDH and the post-traumatic intervals and were found to be statistically significant. A rough attempt was made to determine the effect of haematoma volume on attenuation and was found out to be statistically insignificant. Conclusion The density of the subdural haematoma decreases with increase in the post-traumatic interval that concurs with the limited number of studies being conducted in the past. We concluded that further sorting of cases could be done according to its age with additional research and uniformity in the methodology. PMID:27190831

  5. Influence of the measuring condition on vibrocardiographic signals acquired on the thorax with a laser Doppler vibrometer

    NASA Astrophysics Data System (ADS)

    Mignanelli, L.; Bauer, G.; Klarmann, M.; Wang, H.; Rembe, C.

    2017-07-01

    Velocity signals acquired with a Laser Doppler Vibrometer on the thorax (Optical Vibrocardiography) contain important information, which have a relation to cardiovascular parameters and cardiovascular diseases. The acquired signal results in a superimposition of vibrations originated from different sources of the human body. Since we study the vibration generated by the heart to reliably detect a characteristic time interval corresponding to the PR interval in the ECG, these disturbance have to be removed by filtering. Moreover, the Laser Doppler Vibrometer measures only in the direction of the laser beam and, thus, the velocity signal is only a projection of the tridimensional movement of the thorax. This work presents an analysis of the influences of the filters and of the measurement direction on the characteristic time interval in Vibrocardiographic signals. Our analysis results in recommended settings for filters and we demonstrate that reliable detection of vibrocardiographic parameters is possible within an angle deviation of 30° in respect to the perpendicular irradiation on the front side of the subject.

  6. It's time to fear! Interval timing in odor fear conditioning in rats

    PubMed Central

    Shionoya, Kiseko; Hegoburu, Chloé; Brown, Bruce L.; Sullivan, Regina M.; Doyère, Valérie; Mouly, Anne-Marie

    2013-01-01

    Time perception is crucial to goal attainment in humans and other animals, and interval timing also guides fundamental animal behaviors. Accumulating evidence has made it clear that in associative learning, temporal relations between events are encoded, and a few studies suggest this temporal learning occurs very rapidly. Most of these studies, however, have used methodologies that do not permit investigating the emergence of this temporal learning. In the present study we monitored respiration, ultrasonic vocalization (USV) and freezing behavior in rats in order to perform fine-grain analysis of fear responses during odor fear conditioning. In this paradigm an initially neutral odor (the conditioned stimulus, CS) predicted the arrival of an aversive unconditioned stimulus (US, footshock) at a fixed 20-s time interval. We first investigated the development of a temporal pattern of responding related to CS-US interval duration. The data showed that during acquisition with odor-shock pairings, a temporal response pattern of respiration rate was observed. Changing the CS-US interval duration from 20-s to 30-s resulted in a shift of the temporal response pattern appropriate to the new duration thus demonstrating that the pattern reflected the learning of the CS-US interval. A temporal pattern was also observed during a retention test 24 h later for both respiration and freezing measures, suggesting that the animals had stored the interval duration in long-term memory. We then investigated the role of intra-amygdalar dopaminergic transmission in interval timing. For this purpose, the D1 dopaminergic receptors antagonist SCH23390 was infused in the basolateral amygdala before conditioning. This resulted in an alteration of timing behavior, as reflected in differential temporal patterns between groups observed in a 24 h retention test off drug. The present data suggest that D1 receptor dopaminergic transmission within the amygdala is involved in temporal processing. PMID:24098277

  7. Algorithms development for the GEM-based detection system

    NASA Astrophysics Data System (ADS)

    Czarski, T.; Chernyshova, M.; Malinowski, K.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zabolotny, W.

    2016-09-01

    The measurement system based on GEM - Gas Electron Multiplier detector - is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an Xray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals and cluster charge values corresponding to the energy spectra.

  8. Do one-time intracompartmental pressure measurements have a high false-positive rate in diagnosing compartment syndrome?

    PubMed

    Whitney, Augusta; O'Toole, Robert V; Hui, Emily; Sciadini, Marcus F; Pollak, Andrew N; Manson, Theodore T; Eglseder, W Andrew; Andersen, Romney C; Lebrun, Christopher; Doro, Christopher; Nascone, Jason W

    2014-02-01

    Intracompartmental pressure measurements are frequently used in the diagnosis of compartment syndrome, particularly in patients with equivocal or limited physical examination findings. Little clinical work has been done to validate the clinical use of intracompartmental pressures or identify associated false-positive rates. We hypothesized that diagnosis of compartment syndrome based on one-time pressure measurements alone is associated with a high false-positive rate. Forty-eight consecutive patients with tibial shaft fractures who were not suspected of having compartment syndrome based on physical examinations were prospectively enrolled. Pressure measurements were obtained in all four compartments at a single point in time immediately after induction of anesthesia using a pressure-monitoring device. Preoperative and intraoperative blood pressure measurements were recorded. The same standardized examination was performed by the attending surgeon preoperatively, postoperatively, and during clinical follow-up for 6 months to assess clinical evidence of acute or late compartment syndrome. No clinical evidence of compartment syndrome was observed postoperatively or during follow-up until 6 months after injury. Using the accepted criteria of delta P of 30 mm Hg from preoperative diastolic blood pressure, 35% of cases (n = 16; 95% confidence interval, 21.5-48.5%) met criteria for compartment syndrome. Raising the threshold to delta P of 20 mm Hg reduced the false-positive rate to 24% (n = 11; 95% confidence interval, 11.1-34.9%). Twenty-two percent (n = 10; 95% confidence interval, 9.5-32.5%) exceeded absolute pressure of 45 mm Hg. A 35% false-positive rate was found for the diagnosis of compartment syndrome in patients with tibial shaft fractures who were not thought to have compartment syndrome by using currently accepted criteria for diagnosis based solely on one-time compartment pressure measurements. Our data suggest that reliance on one-time intracompartmental pressure measurements can overestimate the rate of compartment syndrome and raise concern regarding unnecessary fasciotomies. Diagnostic study, level II.

  9. Noninvasive Ph-telemetric Measurement of Gastrointestinal Function

    NASA Technical Reports Server (NTRS)

    Tietze, Karen J.

    1991-01-01

    The purpose of this study was to gain experience with and validate the Heidelberg pH-telemetric methodology in order to determine if the pH-telemetric methodology would be a useful noninvasive measure of gastrointestinal transit time for future ground-based and in-flight drug evaluation studies. The Heidelberg pH metering system is a noninvasive, nonradioactive telemetric system that, following oral ingestion, continuously measures intraluminal pH of the stomach, duodenum, small bowel, ileocecal junction, and large bowel. Gastrointestinal motility profiles were obtained in normal volunteers using the lactulose breath-hydrogen and Heidelberg pH metering techniques. All profiles were obtained in the morning after an overnight fast. Heidelberg pH profiles were obtained in the fasting and fed states; lactulose breath-hydrogen profiles were obtained after a standard breakfast. Mouth-to-cecum transit time was measured as the interval from administration of lactulose (30 ml; 20 g) to a sustained increase in breath-hydrogen of 10 ppm or more. Gastric emptying time was measured as the interval from the administration of the Heidelberg capsule to a sustained increase in pH of three units or more.

  10. Measurement Scale Influences in the Evaluation of Sight-Word Reading Interventions

    ERIC Educational Resources Information Center

    Yaw, Jared; Skinner, Christopher H.; Delisle, Jean; Skinner, Amy L.; Maurer, Kristin; Cihak, David; Wilhoit, Brian; Booher, Joshua

    2014-01-01

    Working with elementary students with disabilities, we used alternating treatment designs to evaluate and compare the effects of 2 computer-based flash card sight-word reading interventions, 1 with 1-s response intervals and another with 5-s response intervals. In Study 1, we held instructional time constant, applying both interventions for 3?min.…

  11. Personalized glucose-insulin model based on signal analysis.

    PubMed

    Goede, Simon L; de Galan, Bastiaan E; Leow, Melvin Khee Shing

    2017-04-21

    Glucose plasma measurements for diabetes patients are generally presented as a glucose concentration-time profile with 15-60min time scale intervals. This limited resolution obscures detailed dynamic events of glucose appearance and metabolism. Measurement intervals of 15min or more could contribute to imperfections in present diabetes treatment. High resolution data from mixed meal tolerance tests (MMTT) for 24 type 1 and type 2 diabetes patients were used in our present modeling. We introduce a model based on the physiological properties of transport, storage and utilization. This logistic approach follows the principles of electrical network analysis and signal processing theory. The method mimics the physiological equivalent of the glucose homeostasis comprising the meal ingestion, absorption via the gastrointestinal tract (GIT) to the endocrine nexus between the liver, pancreatic alpha and beta cells. This model demystifies the metabolic 'black box' by enabling in silico simulations and fitting of individual responses to clinical data. Five-minute intervals MMTT data measured from diabetic subjects result in two independent model parameters that characterize the complete glucose system response at a personalized level. From the individual data measurements, we obtain a model which can be analyzed with a standard electrical network simulator for diagnostics and treatment optimization. The insulin dosing time scale can be accurately adjusted to match the individual requirements of characterized diabetic patients without the physical burden of treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Non-Markovianity quantifier of an arbitrary quantum process

    NASA Astrophysics Data System (ADS)

    Debarba, Tiago; Fanchini, Felipe F.

    2017-12-01

    Calculating the degree of non-Markovianity of a quantum process, for a high-dimensional system, is a difficult task given complex maximization problems. Focusing on the entanglement-based measure of non-Markovianity we propose a numerically feasible quantifier for finite-dimensional systems. We define the non-Markovianity measure in terms of a class of entanglement quantifiers named witnessed entanglement which allow us to write several entanglement based measures of non-Markovianity in a unique formalism. In this formalism, we show that the non-Markovianity, in a given time interval, can be witnessed by calculating the expectation value of an observable, making it attractive for experimental investigations. Following this property we introduce a quantifier base on the entanglement witness in an interval of time; we show that measure is a bonafide measure of non-Markovianity. In our example, we use the generalized robustness of entanglement, an entanglement measure that can be readily calculated by a semidefinite programming method, to study impurity atoms coupled to a Bose-Einstein condensate.

  13. Preliminary Investigation of the Satellite Gravitational Red Shift Experiment

    NASA Technical Reports Server (NTRS)

    Zacharias, J. R.; Searle, C. L.; Graham, J. W.; Badessa, R. S.; Bates, V. J.; Kent, R. L.

    1961-01-01

    The work performed under this contract involved study, design, and construction of experimental equipment to perform a short-term measurement of the gravitational red shift. In the system designed, phase comparison techniques are employed so that the time interval required to obtain a single measurement for one altitude is of the order of one minute. An elliptical orbit was chosen to permit measurement of frequency shift as a function of altitude. One particularly attractive orbit is that having a 12-hour orbiting period (perigee, 270 miles, apogee 24,800 miles). This orbit, shown in Fig. 1, allows continuous measurements to be made over an 11-hour interval during which time the altitude is varying greatly. Measurements can not be made for the succeeding 14 hours. Since the variation of frequency difference with altitude is of greatest interest, a fixed offset or a slow drift between the oscillator on the ground and. the oscillator in the satellite will not invalidate the measurements.

  14. Automated Algorithm for J-Tpeak and Tpeak-Tend Assessment of Drug-Induced Proarrhythmia Risk

    DOE PAGES

    Johannesen, Lars; Vicente, Jose; Hosseini, Meisam; ...

    2016-12-30

    Prolongation of the heart rate corrected QT (QTc) interval is a sensitive marker of torsade de pointes risk; however it is not specific as QTc prolonging drugs that block inward currents are often not associated with torsade. Recent work demonstrated that separate analysis of the heart rate corrected J-T peakc (J-T peakc) and T peak-T end intervals can identify QTc prolonging drugs with inward current block and is being proposed as a part of a new cardiac safety paradigm for new drugs (the “CiPA” initiative). In this work, we describe an automated measurement methodology for assessment of the J-T peakcmore » and T peak-T end intervals using the vector magnitude lead. The automated measurement methodology was developed using data from one clinical trial and was evaluated using independent data from a second clinical trial. Comparison between the automated and the prior semi-automated measurements shows that the automated algorithm reproduces the semi-automated measurements with a mean difference of single-deltas <1 ms and no difference in intra-time point variability (p for all > 0.39). In addition, the time-profile of the baseline and placebo-adjusted changes are within 1 ms for 63% of the time-points (86% within 2 ms). Importantly, the automated results lead to the same conclusions about the electrophysiological mechanisms of the studied drugs. We have developed an automated algorithm for assessment of J-T peakc and T peak-T end intervals that can be applied in clinical drug trials. Under the CiPA initiative this ECG assessment would determine if there are unexpected ion channel effects in humans compared to preclinical studies. In conclusion, the algorithm is being released as open-source software.« less

  15. Automated Algorithm for J-Tpeak and Tpeak-Tend Assessment of Drug-Induced Proarrhythmia Risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johannesen, Lars; Vicente, Jose; Hosseini, Meisam

    Prolongation of the heart rate corrected QT (QTc) interval is a sensitive marker of torsade de pointes risk; however it is not specific as QTc prolonging drugs that block inward currents are often not associated with torsade. Recent work demonstrated that separate analysis of the heart rate corrected J-T peakc (J-T peakc) and T peak-T end intervals can identify QTc prolonging drugs with inward current block and is being proposed as a part of a new cardiac safety paradigm for new drugs (the “CiPA” initiative). In this work, we describe an automated measurement methodology for assessment of the J-T peakcmore » and T peak-T end intervals using the vector magnitude lead. The automated measurement methodology was developed using data from one clinical trial and was evaluated using independent data from a second clinical trial. Comparison between the automated and the prior semi-automated measurements shows that the automated algorithm reproduces the semi-automated measurements with a mean difference of single-deltas <1 ms and no difference in intra-time point variability (p for all > 0.39). In addition, the time-profile of the baseline and placebo-adjusted changes are within 1 ms for 63% of the time-points (86% within 2 ms). Importantly, the automated results lead to the same conclusions about the electrophysiological mechanisms of the studied drugs. We have developed an automated algorithm for assessment of J-T peakc and T peak-T end intervals that can be applied in clinical drug trials. Under the CiPA initiative this ECG assessment would determine if there are unexpected ion channel effects in humans compared to preclinical studies. In conclusion, the algorithm is being released as open-source software.« less

  16. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR

    PubMed Central

    Mobli, Mehdi; Hoch, Jeffrey C.

    2017-01-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. PMID:25456315

  17. Classification of cardiac rhythm using heart rate dynamical measures: validation in MIT-BIH databases.

    PubMed

    Carrara, Marta; Carozzi, Luca; Moss, Travis J; de Pasquale, Marco; Cerutti, Sergio; Lake, Douglas E; Moorman, J Randall; Ferrario, Manuela

    2015-01-01

    Identification of atrial fibrillation (AF) is a clinical imperative. Heartbeat interval time series are increasingly available from personal monitors, allowing new opportunity for AF diagnosis. Previously, we devised numerical algorithms for identification of normal sinus rhythm (NSR), AF, and SR with frequent ectopy using dynamical measures of heart rate. Here, we wished to validate them in the canonical MIT-BIH ECG databases. We tested algorithms on the NSR, AF and arrhythmia databases. When the databases were combined, the positive predictive value of the new algorithms exceeded 95% for NSR and AF, and was 40% for SR with ectopy. Further, dynamical measures did not distinguish atrial from ventricular ectopy. Inspection of individual 24hour records showed good correlation of observed and predicted rhythms. Heart rate dynamical measures are effective ingredients in numerical algorithms to classify cardiac rhythm from the heartbeat intervals time series alone. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Time estimation as a secondary task to measure workload: Summary of research

    NASA Technical Reports Server (NTRS)

    Hart, S. G.; Mcpherson, D.; Loomis, L. L.

    1978-01-01

    Actively produced intervals of time were found to increase in length and variability, whereas retrospectively produced intervals decreased in length although they also increased in variability with the addition of a variety of flight-related tasks. If pilots counted aloud while making a production, however, the impact of concurrent activity was minimized, at least for the moderately demanding primary tasks that were selected. The effects of feedback on estimation accuracy and consistency were greatly enhanced if a counting or tapping production technique was used. This compares with the minimal effect that feedback had when no overt timekeeping technique was used. Actively made verbal estimates of sessions filled with different activities performed during the interval were increased. Retrospectively made verbal estimates, however, increased in length as the amount and complexity of activities performed during the interval were increased.

  19. Effect of insertion method and postinsertion time interval prior to force application on the removal torque of orthodontic miniscrews.

    PubMed

    Sharifi, Maryam; Ghassemi, Amirreza; Bayani, Shahin

    2015-01-01

    Success of orthodontic miniscrews in providing stable anchorage is dependent on their stability. The purpose of this study was to assess the effect of insertion method and postinsertion time interval on the removal torque of miniscrews as an indicator of their stability. Seventy-two miniscrews (Jeil Medical) were inserted into the femoral bones of three male German Shepherd dogs and assigned to nine groups of eight miniscrews. Three insertion methods, including hand-driven, motor-driven with 5.0-Ncm insertion torque, and motor-driven with 20.0-Ncm insertion torque, were tested. Three time intervals of 0, 2, and 6 weeks between miniscrew insertion and removal were tested as well. Removal torque values were measured in newton centimeters by a removal torque tester (IMADA). Data were analyzed by one-way analysis of variance (ANOVA) followed by the Bonferroni post hoc test at a .05 level of significance. A miniscrew survival rate of 93% was observed in this study. The highest mean value of removal torque among the three postinsertion intervals (2.4 ± 0.59 Ncm) was obtained immediately after miniscrew insertion with a statistically significant difference from the other two time intervals (P < .001). Insertion were observed in this regard (P = .46). The stability of miniscrews was not affected by the insertion method. However, of the postinsertion time intervals, the highest removal torque values were obtained immediately after insertion.

  20. An Assessment of Fixed Interval Timing in Free-Flying Honey Bees (Apis mellifera ligustica): An Analysis of Individual Performance

    PubMed Central

    Craig, David Philip Arthur; Varnon, Christopher A.; Sokolowski, Michel B. C.; Wells, Harrington; Abramson, Charles I.

    2014-01-01

    Interval timing is a key element of foraging theory, models of predator avoidance, and competitive interactions. Although interval timing is well documented in vertebrate species, it is virtually unstudied in invertebrates. In the present experiment, we used free-flying honey bees (Apis mellifera ligustica) as a model for timing behaviors. Subjects were trained to enter a hole in an automated artificial flower to receive a nectar reinforcer (i.e. reward). Responses were continuously reinforced prior to exposure to either a fixed interval (FI) 15-sec, FI 30-sec, FI 60-sec, or FI 120-sec reinforcement schedule. We measured response rate and post-reinforcement pause within each fixed interval trial between reinforcers. Honey bees responded at higher frequencies earlier in the fixed interval suggesting subject responding did not come under traditional forms of temporal control. Response rates were lower during FI conditions compared to performance on continuous reinforcement schedules, and responding was more resistant to extinction when previously reinforced on FI schedules. However, no “scalloped” or “break-and-run” patterns of group or individual responses reinforced on FI schedules were observed; no traditional evidence of temporal control was found. Finally, longer FI schedules eventually caused all subjects to cease returning to the operant chamber indicating subjects did not tolerate the longer FI schedules. PMID:24983960

  1. Reliability of patient-reported outcomes in rheumatoid arthritis patients: an observational prospective study.

    PubMed

    Studenic, Paul; Stamm, Tanja; Smolen, Josef S; Aletaha, Daniel

    2016-01-01

    Patient-reported outcomes (PROs) such as pain, patient global assessment (PGA) and fatigue are regularly assessed in RA patients. In the present study, we aimed to explore the reliability and smallest detectable differences (SDDs) of these PROs, and whether the time between assessments has an impact on reliability. Forty RA patients on stable treatment reported the three PROs daily over two subsequent months. We assessed the reliability of these measures by calculating intraclass correlation coefficients (ICCs) and the SDDs for 1-, 7-, 14- and 28-day test-retest intervals. Overall, SDD and ICC were 25 mm and 0.67 for pain, 25 mm and 0.71 for PGA and 30 mm and 0.66 for fatigue, respectively. SDD was higher with longer time period between assessments, ranging from 19 mm (1-day intervals) to 30 mm (28-day intervals) for pain, 19 to 33 mm for PGA, and 26 to 34 mm for fatigue; correspondingly, ICC was smaller with longer intervals, and ranged between the 1- and the 28-day interval from 0.80 to 0.50 for pain, 0.83 to 0.57 for PGA and 0.76 to 0.58 for fatigue. The baseline simplified disease activity index did not have any influence on reliability. Lower baseline PRO scores led to smaller SDDs. Reliability of pain, PGA and fatigue measurements is dependent on the tested time interval and the baseline levels. The relatively high SDDs, even for patients in the lowest tertiles of their PROs, indicate potential issues for assessment of the presence of remission. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Influence of Inter-Training Intervals on Intermanual Transfer Effects in Upper-Limb Prosthesis Training: A Randomized Pre-Posttest Study.

    PubMed

    Romkema, Sietske; Bongers, Raoul M; van der Sluis, Corry K

    2015-01-01

    Improvement in prosthetic training using intermanual transfer (the transfer of motor skills from the trained, “unaffected” hand to the untrained, “affected” hand) has been shown in previous studies. The aim of this study is to determine the influence of the inter-training interval on the magnitude of the intermanual transfer effects. This was done using a mechanistic, randomized, single-blinded pretest-posttest design. Sixty-four able-bodied, right-handed participants were randomly assigned to the Short and Long Interval Training Groups and the Short and Long Interval Control Groups. The Short and Long Interval Training Groups used a prosthesis simulator in their training program. The Short and Long Interval Control Groups executed a sham training program, that is, a dummy training program in which the same muscles were trained as with the prosthesis simulator. The Short Interval Training Group and the Short Interval Control Groups trained on consecutive days, while the Long Interval Training Group and Long Interval Control Group trained twice a week. To determine the improvement in skills, a test was administered before, immediately after, and at two points in time after the training. Training was performed with the “unaffected” arm; tests were performed with the “affected” arm. The outcome measurements were: the movement time (the time from the beginning of the movement until completion of the task); the duration of maximum hand opening, (the opening of the prosthetic hand while grasping an object); and the grip-force control (the error from the required grip-force during a tracking task). Intermanual transfer was found in movement times, but not in hand opening or grip-force control. The length of the inter-training interval did not affect the magnitude of intermanual transfer effects. No difference in the intermanual transfer effect in upper-limb prosthesis training was found for training on a daily basis as compared to training twice a week. Nederlands Trial Register NTR3888.

  3. Influence of Inter-Training Intervals on Intermanual Transfer Effects in Upper-Limb Prosthesis Training: A Randomized Pre-Posttest Study

    PubMed Central

    Romkema, Sietske; Bongers, Raoul M.; van der Sluis, Corry K.

    2015-01-01

    Improvement in prosthetic training using intermanual transfer (the transfer of motor skills from the trained, “unaffected” hand to the untrained, “affected” hand) has been shown in previous studies. The aim of this study is to determine the influence of the inter-training interval on the magnitude of the intermanual transfer effects. This was done using a mechanistic, randomized, single-blinded pretest-posttest design. Sixty-four able-bodied, right-handed participants were randomly assigned to the Short and Long Interval Training Groups and the Short and Long Interval Control Groups. The Short and Long Interval Training Groups used a prosthesis simulator in their training program. The Short and Long Interval Control Groups executed a sham training program, that is, a dummy training program in which the same muscles were trained as with the prosthesis simulator. The Short Interval Training Group and the Short Interval Control Groups trained on consecutive days, while the Long Interval Training Group and Long Interval Control Group trained twice a week. To determine the improvement in skills, a test was administered before, immediately after, and at two points in time after the training. Training was performed with the “unaffected” arm; tests were performed with the “affected” arm. The outcome measurements were: the movement time (the time from the beginning of the movement until completion of the task); the duration of maximum hand opening, (the opening of the prosthetic hand while grasping an object); and the grip-force control (the error from the required grip-force during a tracking task). Intermanual transfer was found in movement times, but not in hand opening or grip-force control. The length of the inter-training interval did not affect the magnitude of intermanual transfer effects. No difference in the intermanual transfer effect in upper-limb prosthesis training was found for training on a daily basis as compared to training twice a week. Trial Registration Nederlands Trial Register NTR3888 PMID:26075396

  4. Incorporating temporal and clinical reasoning in a new measure of continuity of care.

    PubMed Central

    Spooner, S. A.

    1994-01-01

    Previously described quantitative methods for measuring continuity of care have assumed that perfect continuity exists when a patient sees only one provider, regardless of the temporal pattern and clinical context of the visits. This paper describes an implementation of a new operational model of continuity--the Temporal Continuity Index--that takes into account time intervals between well visits in a pediatric residency continuity clinic. Ideal continuity in this model is achieved when intervals between visits are appropriate based on the age of the patient and clinical context of the encounters. The fundamental concept in this model is the expectation interval, which contains the length of the maximum ideal follow-up interval for a visit and the maximum follow-up interval. This paper describes an initial implementation of the TCI model and compares TCI calculations to previous quantitative methods and proposes its use as part of the assessment of resident education in outpatient settings. PMID:7950019

  5. Measurement Equivalence of Teachers' Sense of Efficacy Scale Using Latent Growth Methods

    ERIC Educational Resources Information Center

    Basokçu, T. Oguz; Ögretmen, T.

    2016-01-01

    This study is based on the application of latent growth modeling, which is one of structural equation models on real data. Teachers' Sense of Efficacy Scale (TSES), which was previously adapted into Turkish was administered to 200 preservice teachers at different time intervals for three times and study data was collected. Measurement equivalence…

  6. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation

    PubMed Central

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-01-01

    Abstract We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients’ duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. PMID:27924066

  7. Music enhances performance and perceived enjoyment of sprint interval exercise.

    PubMed

    Stork, Matthew J; Kwan, Matthew Y W; Gibala, Martin J; Martin Ginis, Kathleen A

    2015-05-01

    Interval exercise training can elicit physiological adaptations similar to those of traditional endurance training, but with reduced time. However, the intense nature of specific protocols, particularly the "all-out" efforts characteristic of sprint interval training (SIT), may be perceived as being aversive. The purpose of this study was to determine whether listening to self-selected music can reduce the potential aversiveness of an acute session of SIT by improving affect, motivation, and enjoyment, and to examine the effects of music on performance. Twenty moderately active adults (22 ± 4 yr) unfamiliar with interval exercise completed an acute session of SIT under two different conditions: music and no music. The exercise consisted of four 30-s "all-out" Wingate Anaerobic Test bouts on a cycle ergometer, separated by 4 min of rest. Peak and mean power output, RPE, affect, task motivation, and perceived enjoyment of the exercise were measured. Mixed-effects models were used to evaluate changes in dependent measures over time and between the two conditions. Peak and mean power over the course of the exercise session were higher in the music condition (coefficient = 49.72 [SE = 13.55] and coefficient = 23.65 [SE = 11.30]; P < 0.05). A significant time by condition effect emerged for peak power (coefficient = -12.31 [SE = 4.95]; P < 0.05). There were no between-condition differences in RPE, affect, or task motivation. Perceived enjoyment increased over time and was consistently higher in the music condition (coefficient = 7.00 [SE = 3.05]; P < 0.05). Music enhances in-task performance and enjoyment of an acute bout of SIT. Listening to music during intense interval exercise may be an effective strategy for facilitating participation in, and adherence to, this form of training.

  8. Measuring Food Use in School-Aged Children.

    ERIC Educational Resources Information Center

    Randall, Elizabeth

    1991-01-01

    Ideal measurement of food use in school-aged children possesses validity, reliability, interpretability, and feasibility. The article discusses dietary records and recalls and measures of patterns in food use. Issues to consider when constructing children's food frequency are food list, time intervals, response set, context of questioning, and…

  9. Magnetic Resonance Fingerprinting with short relaxation intervals.

    PubMed

    Amthor, Thomas; Doneva, Mariya; Koken, Peter; Sommer, Karsten; Meineke, Jakob; Börnert, Peter

    2017-09-01

    The aim of this study was to investigate a technique for improving the performance of Magnetic Resonance Fingerprinting (MRF) in repetitive sampling schemes, in particular for 3D MRF acquisition, by shortening relaxation intervals between MRF pulse train repetitions. A calculation method for MRF dictionaries adapted to short relaxation intervals and non-relaxed initial spin states is presented, based on the concept of stationary fingerprints. The method is applicable to many different k-space sampling schemes in 2D and 3D. For accuracy analysis, T 1 and T 2 values of a phantom are determined by single-slice Cartesian MRF for different relaxation intervals and are compared with quantitative reference measurements. The relevance of slice profile effects is also investigated in this case. To further illustrate the capabilities of the method, an application to in-vivo spiral 3D MRF measurements is demonstrated. The proposed computation method enables accurate parameter estimation even for the shortest relaxation intervals, as investigated for different sampling patterns in 2D and 3D. In 2D Cartesian measurements, we achieved a scan acceleration of more than a factor of two, while maintaining acceptable accuracy: The largest T 1 values of a sample set deviated from their reference values by 0.3% (longest relaxation interval) and 2.4% (shortest relaxation interval). The largest T 2 values showed systematic deviations of up to 10% for all relaxation intervals, which is discussed. The influence of slice profile effects for multislice acquisition is shown to become increasingly relevant for short relaxation intervals. In 3D spiral measurements, a scan time reduction of 36% was achieved, maintaining the quality of in-vivo T1 and T2 maps. Reducing the relaxation interval between MRF sequence repetitions using stationary fingerprint dictionaries is a feasible method to improve the scan efficiency of MRF sequences. The method enables fast implementations of 3D spatially resolved MRF. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Precipitation-Frequency and Discharge-Frequency Relations for Basins Less than 32 Square Miles in Kansas

    USGS Publications Warehouse

    Perry, Charles A.

    2008-01-01

    Precipitation-frequency and discharge-frequency relations for small drainage basins with areas less than 32 square miles in Kansas were evaluated to reduce the uncertainty of discharge-frequency estimates. Gaged-discharge records were used to develop discharge-frequency equations for the ratio of discharge to drainage area (Q/A) values using data from basins with variable soil permeability, channel slope, and mean annual precipitation. Soil permeability and mean annual precipitation are the dominant basin characteristics in the multiple linear regression analyses. In addition, 28 discharge measurements at ungaged sites by indirect surveying methods and by velocity meters also were used in this analysis to relate precipitation-recurrence interval to discharge-recurrence interval. Precipitation-recurrence interval for each of these discharge measurements were estimated from weather-radar estimates of precipitation and from nearby raingages. Time of concentration for each basin for each of the ungaged sites was computed and used to determine the precipitation-recurrence interval based on precipitation depth and duration. The ratio of discharge/drainage area (Q/A) value for each event was then assigned to that precipitation-recurrence interval. The relation between the ratio of discharge/drainage area (Q/A) and precipitation-recurrence interval for all 28 measured events resulted in a correlation coefficient of 0.79. Using basins less than 5.4 mi2 only, the correlation decreases to 0.74. However, when basins greater than 5.4 and less than 32 mi2 are examined the relation improves to a correlation coefficient of 0.95. There were a sufficient number of discharge and radar-measured precipitation events for both the 5-year (8 events) and the 100-year (11 events) recurrence intervals to examine the effect of basin characteristics on the Q/A values for basins less than 32 mi2. At the 5-year precipitation-/discharge-recurrence interval, channel slope was a significant predictor (r=0.99) of Q/A. Permeability (r=0.68) also had a significant effect on Q/A values for the 5-year recurrence interval. At the 100-year recurrence interval, permeability, channel slope, and mean annual precipitation did not have a significant effect on Q/A; however, time of concentration was a significant factor in determining Q/A for the 100-year events with greater times of concentration resulting in lower Q/A values. Additional high-recurrence interval (5-, 10-, 25-, 50-, and 100-year) precipitation/discharge data are needed to confirm these relations suggested above. Discharge data with attendant basin-wide precipitation data from precipitation-radar estimates provides a unique opportunity to study the effects of basin characteristics on the relation between precipitation recurrence interval and discharge-recurrence interval. Discharge-frequency values from the Q/A equations, the rational method, and the Kansas discharge-frequency equations (KFFE) were compared to 28 measured weather-radar precipitation-/discharge-frequency values. The association between precipitation frequency from weather-radar estimates and the frequency of the resulting discharge was shown in these comparisons. The measured and Q/A equation computed discharges displayed the best equality from low to high discharges of the three methods. Here the slope of the line was nearly 1:1 (y=0.9844x0.9677). Comparisons with the rational method produced a slope greater than 1:1 (y=0.0722x1.235), and the KFFE equations produced a slope less than 1:1 (y=5.9103x0.7475). The Q/A equation standard error of prediction averaged 0.1346 log units for the 5.4-to 32-square-mile group and 0.0944 log units for the less than 5.4-square mile group. The KFFE standard error averaged 0.2107 log units for the less-than-30-square-mile equations. Using the Q/A equations for determining discharge frequency values for ungaged sites thus appears to be a good alternative to the other two methods because of this s

  11. Methoxyflurane anesthesia augments the chronotropic and dromotropic effects of verapamil.

    PubMed

    Jamali, F; Mayo, P R

    1999-01-01

    Inhalation anesthetics have been shown to have electrical suppressant effects on excitable membranes such as the cardiac conduction system. Therefore, the anesthetized patient or laboratory animal may respond differently to cardiac drugs when compared with their conscious counterparts. The purpose of this study was to assess the effects of anesthesia with methoxyflurane (MF) on the dromotropic and chronotropic effects of verapamil (VER) in the rat. A lead I ECG was measured using subcutaneous electrodes placed both axilli and over the xyphoid process in male Sprague-Dawley rats. Dromotropic effect was measured using the PR-interval which indicated the electrical spread across the atria to the AV-node and chronotropic effects were determined using RR-interval. A total of six animals were randomized to receive 10 mg/kg s.c. of verapamil in the presence or absence of general anesthesia containing methoxyflurane. In addition, PR-interval and RR-intervals were determined in the presence of only methoxyflurane and at rest without any drug exposure. The time for the ECG to normalize after exposure to methoxyflurane and/or verapamil was also determined. Exposure to verapamil alone resulted in a 5% prolongation in PR-interval and 6% prolongation in RR-interval. Methoxyflurane alone had a larger effect than verapamil demonstrating a 14.5% prolongation in PR-interval and a 12.3% in RR-interval which was statistically significant. The combination of MF + VER resulted in a synergistic prolongation in PR-interval to 28. 7% while the effect on RR-interval was additive with an increase to 17.6%. The time for the ECG to normalize after exposure to VER, MF and VER + MF was 37.5 15.1 min, 69.8 5.3 min, and 148.5 +/- 6.6 min respectively. General anesthesia with MF enhances the dromotropic and chronotropic effect of VER. This should be considered when MF-anesthesia is used in experimental procedure.

  12. Structure-oriented versus process-oriented approach to enhance efficiency for emergency room operations: what lessons can we learn?

    PubMed

    Hwang, Taik Gun; Lee, Younsuk; Shin, Hojung

    2011-01-01

    The efficiency and quality of a healthcare system can be defined as interactions among the system structure, processes, and outcome. This article examines the effect of structural adjustment (change in floor plan or layout) and process improvement (critical pathway implementation) on performance of emergency room (ER) operations for acute cerebral infarction patients. Two large teaching hospitals participated in this study: Korea University (KU) Guro Hospital and KU Anam Hospital. The administration of Guro adopted a structure-oriented approach in improving its ER operations while the administration of Anam employed a process-oriented approach, facilitating critical pathways and protocols. To calibrate improvements, the data for time interval, length of stay, and hospital charges were collected, before and after the planned changes were implemented at each hospital. In particular, time interval is the most essential measure for handling acute stroke patients because patients' survival and recovery are affected by the promptness of diagnosis and treatment. Statistical analyses indicated that both redesign of layout at Guro and implementation of critical pathways at Anam had a positive influence on most of the performance measures. However, reduction in time interval was not consistent at Guro, demonstrating delays in processing time for a few processes. The adoption of critical pathways at Anam appeared more effective in reducing time intervals than the structural rearrangement at Guro, mainly as a result of the extensive employee training required for a critical pathway implementation. Thus, hospital managers should combine structure-oriented and process-oriented strategies to maximize effectiveness of improvement efforts.

  13. An actual load forecasting methodology by interval grey modeling based on the fractional calculus.

    PubMed

    Yang, Yang; Xue, Dingyü

    2017-07-17

    The operation processes for thermal power plant are measured by the real-time data, and a large number of historical interval data can be obtained from the dataset. Within defined periods of time, the interval information could provide important information for decision making and equipment maintenance. Actual load is one of the most important parameters, and the trends hidden in the historical data will show the overall operation status of the equipments. However, based on the interval grey parameter numbers, the modeling and prediction process is more complicated than the one with real numbers. In order not lose any information, the geometric coordinate features are used by the coordinates of area and middle point lines in this paper, which are proved with the same information as the original interval data. The grey prediction model for interval grey number by the fractional-order accumulation calculus is proposed. Compared with integer-order model, the proposed method could have more freedom with better performance for modeling and prediction, which can be widely used in the modeling process and prediction for the small amount interval historical industry sequence samples. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Paleomagnetic and rock magnetic study of IODP Site U1408 in the Northwest Atlantic - toward the high-resolution relative paleointensity estimate during the middle Eocene

    NASA Astrophysics Data System (ADS)

    Yamamoto, Y.; Yamazaki, T.; Oda, H.

    2015-12-01

    We have conducted paleomagnetic and rock magnetic measurements on the sedimentary sections recovered from Integrated Ocean Drilling Program (IODP) Site U1408 in the Northwest Atlantic, off Newfoundland. The measurements were done on u-channel samples using a pass-through superconducting rock magnetometer in a manner that remanent magnetizations (natural, anhysteretic and isothermal remanent magnetizations: NRM, ARM and IRM) were subjected to stepwise alternating field (AF) demagnetizations up to 80 mT and are measured with 1 cm spacing at each step.The characteristic remanent magnetization (ChRM) was resolved after AF demagnetization of 20-30 mT for most of the studied interval. As a result, we could identify several polarity reversals which were able to be correlated with the geomagnetic polarity time scale by Gradstein et al. (2012) (Geologic Time Scale 2012), with referring the shipboard biostratigraphy (Norris et al., 2014). The interval at ~ 33-157 mcd (meter composite depth) was interpreted to cover the Chrons C18n.1n to C20n with missing Chron C19n because of the somewhat ambiguous magnetic signals at the interval at ~ 70-110 mcd. The correlation provided an age model inferring sedimentation rate of about 2-4 cm/kyr during these chrons.There is the interval that shows relatively constant ARM and IRM intensities as well as ratios of ARM to IRM (ARM/IRM): the interval at ~ 37-90 mcd resulted in ARM intensity of 0.2-0.4 A/m, IRM intensity of 1-2 A/m and ARM/IRM of 0.17-0.20. This interval corresponds to the Chron C18 and the estimated sedimentation rate of the interval is ~ 2 cm/kyr. It is expected that high-resolution relative paleointensity estimate during the middle Eocene is potentially possible. We will report a preliminary estimate.

  15. Swimming performance in juvenile shortnose sturgeon (Acipenser brevirostrum): the influence of time interval and velocity increments on critical swimming tests

    PubMed Central

    Kieffer, James D.

    2017-01-01

    Abstract The most utilized method to measure swimming performance of fishes has been the critical swimming speed (UCrit) test. In this test, the fish is forced to swim against an incrementally increasing flow of water until fatigue. Before the water velocity is increased, the fish swims at the water velocity for a specific, pre-arranged time interval. The magnitude of the velocity increments and the time interval for each swimming period can vary across studies making the comparison between and within species difficult. This issue has been acknowledged in the literature, however, little empirical evidence exists that tests the importance of velocity and time increments on swimming performance in fish. A practical application for fish performance is through the design of fishways that enable fish to bypass anthropogenic structures (e.g. dams) that block migration routes, which is one of the causes of world-wide decline in sturgeon populations. While fishways will improve sturgeon conservation, they need to be specifically designed to accommodate the swimming capabilities specific for sturgeons, and it is possible that current swimming methodologies have under-estimated the swimming performance of sturgeons. The present study assessed the UCrit of shortnose sturgeon using modified UCrit to determine the importance of velocity increment (5 and 10 cm s−1) and time (5, 15 and 30 min) intervals on swimming performance. UCrit was found to be influenced by both time interval and water velocity. UCrit was generally lower in sturgeon when they were swum using 5cm s−1 compared with 10 cm s−1 increments. Velocity increment influences the UCrit more than time interval. Overall, researchers must consider the impacts of using particular swimming criteria when designing their experiments. PMID:28835841

  16. Development of a New Paradigm for Analysis of Disdrometric Data

    NASA Astrophysics Data System (ADS)

    Larsen, Michael L.; Kostinski, Alexander B.

    2017-04-01

    A number of disdrometers currently on the market are able to characterize hydrometeors on a drop-by-drop basis with arrival timestamps associated with each arriving hydrometeor. This allows an investigator to parse a time series into disjoint intervals that have equal numbers of drops, instead of the traditional subdivision into equal time intervals. Such a "fixed-N" partitioning of the data can provide several advantages over the traditional equal time binning method, especially within the context of quantifying measurement uncertainty (which typically scales with the number of hydrometeors in each sample). An added bonus is the natural elimination of measurements that are devoid of all drops. This analysis method is investigated by utilizing data from a dense array of disdrometers located near Charleston, South Carolina, USA. Implications for the usefulness of this method in future studies are explored.

  17. Glossary-HDSC/OWP

    Science.gov Websites

    Glossary Precipitation Frequency Data Server GIS Grids Maps Time Series Temporals Documents Probable provides a measure of the average time between years (and not events) in which a particular value is RECCURENCE INTERVAL). ANNUAL MAXIMUM SERIES (AMS) - Time series of the largest precipitation amounts in a

  18. Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stimpfle, R.M.; Lapson, L.B., Wennberg, P.O.; Anderson, J.G.

    1989-12-01

    The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser induced fluorescence instrument employing a 17 kHz repetition rate copper vapor laser pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 {plus minus} 31 pptv (1.1 {plus minus} 0.4 {times} 10{sup 7} molec cm{sup {minus}3}) in the 36 to 35 km interval to 0.9 {plus minus} 0.8 pptv (8.7 {plus minus} 7.7 {times}10{supmore » 5} molec cm{sup {minus}3}) in the 24 to 23 km interval. The stated uncertainty ({plus minus} 1{sigma}) includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.« less

  19. The Locomotion of Mouse Fibroblasts in Tissue Culture

    PubMed Central

    Gail, Mitchell H.; Boone, Charles W.

    1970-01-01

    Time-lapse cinematography was used to investigate the motion of mouse fibroblasts in tissue culture. Observations over successive short time intervals revealed a tendency for the cells to persist in their direction of motion from one 2.5 hr time interval to the next. Over 5.0-hr time intervals, however, the direction of motion appeared random. This fact suggested that D, the diffusion constant of a random walk model, might serve to characterize cellular motility if suitably long observation times were used. We therefore investigated the effect of “persistence” on the pure random walk model, and we found theoretically and confirmed experimentally that the motility of a persisting cell could indeed be characterized by an augmented diffusion constant, D*. A method for determining confidence limits on D* was also developed. Thus a random walk model, modified to comprehend the persistence effect, was found to describe the motion of fibroblasts in tissue culture and to provide a numerical measure of cellular motility. PMID:5531614

  20. Theoretical implications of quantitative properties of interval timing and probability estimation in mouse and rat.

    PubMed

    Kheifets, Aaron; Freestone, David; Gallistel, C R

    2017-07-01

    In three experiments with mice ( Mus musculus ) and rats (Rattus norvigicus), we used a switch paradigm to measure quantitative properties of the interval-timing mechanism. We found that: 1) Rodents adjusted the precision of their timed switches in response to changes in the interval between the short and long feed latencies (the temporal goalposts). 2) The variability in the timing of the switch response was reduced or unchanged in the face of large trial-to-trial random variability in the short and long feed latencies. 3) The adjustment in the distribution of switch latencies in response to changes in the relative frequency of short and long trials was sensitive to the asymmetry in the Kullback-Leibler divergence. The three results suggest that durations are represented with adjustable precision, that they are timed by multiple timers, and that there is a trial-by-trial (episodic) record of feed latencies in memory. © 2017 Society for the Experimental Analysis of Behavior.

  1. Fractal correlation properties of R-R interval dynamics and mortality in patients with depressed left ventricular function after an acute myocardial infarction

    NASA Technical Reports Server (NTRS)

    Huikuri, H. V.; Makikallio, T. H.; Peng, C. K.; Goldberger, A. L.; Hintze, U.; Moller, M.

    2000-01-01

    BACKGROUND: Preliminary data suggest that the analysis of R-R interval variability by fractal analysis methods may provide clinically useful information on patients with heart failure. The purpose of this study was to compare the prognostic power of new fractal and traditional measures of R-R interval variability as predictors of death after acute myocardial infarction. METHODS AND RESULTS: Time and frequency domain heart rate (HR) variability measures, along with short- and long-term correlation (fractal) properties of R-R intervals (exponents alpha(1) and alpha(2)) and power-law scaling of the power spectra (exponent beta), were assessed from 24-hour Holter recordings in 446 survivors of acute myocardial infarction with a depressed left ventricular function (ejection fraction

  2. Insulin Test

    MedlinePlus

    ... sometimes used in conjunction with the glucose tolerance test (GTT) . In this situation, blood glucose and insulin levels are measured at pre-established time intervals to evaluate insulin resistance. When ...

  3. The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

    NASA Astrophysics Data System (ADS)

    Czarski, T.; Chernyshova, M.; Malinowski, K.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Wojenski, A.; Zabolotny, W.

    2016-11-01

    The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

  4. The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics.

    PubMed

    Czarski, T; Chernyshova, M; Malinowski, K; Pozniak, K T; Kasprowicz, G; Kolasinski, P; Krawczyk, R; Wojenski, A; Zabolotny, W

    2016-11-01

    The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

  5. Making Time for Nature: Visual Exposure to Natural Environments Lengthens Subjective Time Perception and Reduces Impulsivity

    PubMed Central

    Berry, Meredith S.; Repke, Meredith A.; Nickerson, Norma P.; Conway, Lucian G.; Odum, Amy L.; Jordan, Kerry E.

    2015-01-01

    Impulsivity in delay discounting is associated with maladaptive behaviors such as overeating and drug and alcohol abuse. Researchers have recently noted that delay discounting, even when measured by a brief laboratory task, may be the best predictor of human health related behaviors (e.g., exercise) currently available. Identifying techniques to decrease impulsivity in delay discounting, therefore, could help improve decision-making on a global scale. Visual exposure to natural environments is one recent approach shown to decrease impulsive decision-making in a delay discounting task, although the mechanism driving this result is currently unknown. The present experiment was thus designed to evaluate not only whether visual exposure to natural (mountains, lakes) relative to built (buildings, cities) environments resulted in less impulsivity, but also whether this exposure influenced time perception. Participants were randomly assigned to either a natural environment condition or a built environment condition. Participants viewed photographs of either natural scenes or built scenes before and during a delay discounting task in which they made choices about receiving immediate or delayed hypothetical monetary outcomes. Participants also completed an interval bisection task in which natural or built stimuli were judged as relatively longer or shorter presentation durations. Following the delay discounting and interval bisection tasks, additional measures of time perception were administered, including how many minutes participants thought had passed during the session and a scale measurement of whether time "flew" or "dragged" during the session. Participants exposed to natural as opposed to built scenes were less impulsive and also reported longer subjective session times, although no differences across groups were revealed with the interval bisection task. These results are the first to suggest that decreased impulsivity from exposure to natural as opposed to built environments may be related to lengthened time perception. PMID:26558610

  6. An apparatus for sequentially combining microvolumes of reagents by infrasonic mixing.

    PubMed

    Camien, M N; Warner, R C

    1984-05-01

    A method employing high-speed infrasonic mixing for obtaining timed samples for following the progress of a moderately rapid chemical reaction is described. Drops of 10 to 50 microliter each of two reagents are mixed to initiate the reaction, followed, after a measured time interval, by mixing with a drop of a third reagent to quench the reaction. The method was developed for measuring the rate of denaturation of covalently closed, circular DNA in NaOH at several temperatures. For this purpose the timed samples were analyzed by analytical ultracentrifugation. The apparatus was tested by determination of the rate of hydrolysis of 2,4-dinitrophenyl acetate in an alkaline buffer. The important characteristics of the method are (i) it requires very small volumes of sample and reagents; (ii) the components of the reaction mixture are pre-equilibrated and mixed with no transfer outside the prescribed constant temperature environment; (iii) the mixing is very rapid; and (iv) satisfactorily precise measurements of relatively short time intervals (approximately 2 sec minimum) between sequential mixings of the components are readily obtainable.

  7. Fourier-transform infrared derivative spectroscopy with an improved signal-to-noise ratio.

    PubMed

    Fetterman, M R

    2005-09-01

    Infrared derivative spectroscopy is a useful technique for finding peaks hidden in broad spectral features. A data acquisition technique is shown that will improve the signal-to-noise ratio (SNR) of Fourier-transform infrared (FTIR) derivative spectroscopy. Typically, in a FTIR measurement one samples each point for the same time interval. The effect of using a graded time interval is studied. The simulations presented show that the SNR of first-derivative FTIR spectroscopy will improve by 15% and that the SNR of second-derivative FTIR will improve by 34%.

  8. A modified interval symmetric single step procedure ISS-5D for simultaneous inclusion of polynomial zeros

    NASA Astrophysics Data System (ADS)

    Sham, Atiyah W. M.; Monsi, Mansor; Hassan, Nasruddin; Suleiman, Mohamed

    2013-04-01

    The aim of this paper is to present a new modified interval symmetric single-step procedure ISS-5D which is the extension from the previous procedure, ISS1. The ISS-5D method will produce successively smaller intervals that are guaranteed to still contain the zeros. The efficiency of this method is measured on the CPU times and the number of iteration. The procedure is run on five test polynomials and the results obtained are shown in this paper.

  9. Map based navigation for autonomous underwater vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tuohy, S.T.; Leonard, J.J.; Bellingham, J.G.

    1995-12-31

    In this work, a map based navigation algorithm is developed wherein measured geophysical properties are matched to a priori maps. The objectives is a complete algorithm applicable to a small, power-limited AUV which performs in real time to a required resolution with bounded position error. Interval B-Splines are introduced for the non-linear representation of two-dimensional geophysical parameters that have measurement uncertainty. Fine-scale position determination involves the solution of a system of nonlinear polynomial equations with interval coefficients. This system represents the complete set of possible vehicle locations and is formulated as the intersection of contours established on each map frommore » the simultaneous measurement of associated geophysical parameters. A standard filter mechanisms, based on a bounded interval error model, predicts the position of the vehicle and, therefore, screens extraneous solutions. When multiple solutions are found, a tracking mechanisms is applied until a unique vehicle location is determined.« less

  10. Dating human skeletal remains: investigating the viability of measuring the equilibrium between 210Po and 210Pb as a means of estimating the post-mortem interval.

    PubMed

    Swift, B

    1998-11-30

    Estimating the post-mortem interval in skeletal remains is a notoriously difficult task; forensic pathologists often rely heavily upon experience in recognising morphological appearances. Previous techniques have involved measuring physical or chemical changes within the hydroxyapatite matrix, radiocarbon dating and 90Sr dating, though no individual test has been advocated. Within this paper it is proposed that measuring the equilibrium between two naturally occurring radio-isotopes, 210Po and 210Pb, and comparison with post-mortem examination samples would produce a new method of dating human skeletal remains. Possible limitations exist, notably the effect of diagenesis, time limitations and relative cost, though this technique could provide a relatively accurate means of determining the post-mortem interval. It is therefore proposed that a large study be undertaken to provide a calibration scale against which bones uncovered can be dated.

  11. RISMA: A Rule-based Interval State Machine Algorithm for Alerts Generation, Performance Analysis and Monitoring Real-Time Data Processing

    NASA Astrophysics Data System (ADS)

    Laban, Shaban; El-Desouky, Aly

    2013-04-01

    The monitoring of real-time systems is a challenging and complicated process. So, there is a continuous need to improve the monitoring process through the use of new intelligent techniques and algorithms for detecting exceptions, anomalous behaviours and generating the necessary alerts during the workflow monitoring of such systems. The interval-based or period-based theorems have been discussed, analysed, and used by many researches in Artificial Intelligence (AI), philosophy, and linguistics. As explained by Allen, there are 13 relations between any two intervals. Also, there have also been many studies of interval-based temporal reasoning and logics over the past decades. Interval-based theorems can be used for monitoring real-time interval-based data processing. However, increasing the number of processed intervals makes the implementation of such theorems a complex and time consuming process as the relationships between such intervals are increasing exponentially. To overcome the previous problem, this paper presents a Rule-based Interval State Machine Algorithm (RISMA) for processing, monitoring, and analysing the behaviour of interval-based data, received from real-time sensors. The proposed intelligent algorithm uses the Interval State Machine (ISM) approach to model any number of interval-based data into well-defined states as well as inferring them. An interval-based state transition model and methodology are presented to identify the relationships between the different states of the proposed algorithm. By using such model, the unlimited number of relationships between similar large numbers of intervals can be reduced to only 18 direct relationships using the proposed well-defined states. For testing the proposed algorithm, necessary inference rules and code have been designed and applied to the continuous data received in near real-time from the stations of International Monitoring System (IMS) by the International Data Centre (IDC) of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO). The CLIPS expert system shell has been used as the main rule engine for implementing the algorithm rules. Python programming language and the module "PyCLIPS" are used for building the necessary code for algorithm implementation. More than 1.7 million intervals constitute the Concise List of Frames (CLF) from 20 different seismic stations have been used for evaluating the proposed algorithm and evaluating stations behaviour and performance. The initial results showed that proposed algorithm can help in better understanding of the operation and performance of those stations. Different important information, such as alerts and some station performance parameters, can be derived from the proposed algorithm. For IMS interval-based data and at any period of time it is possible to analyze station behavior, determine the missing data, generate necessary alerts, and to measure some of station performance attributes. The details of the proposed algorithm, methodology, implementation, experimental results, advantages, and limitations of this research are presented. Finally, future directions and recommendations are discussed.

  12. Methane oxidation behind reflected shock waves: Ignition delay times measured by pressure and flame band emission

    NASA Technical Reports Server (NTRS)

    Brabbs, T. A.; Robertson, T. F.

    1986-01-01

    Ignition delay data were recorded for three methane-oxygen-argon mixtures (phi = 0.5, 1.0, 2.0) for the temperature range 1500 to 1920 K. Quiet pressure trances enabled us to obtain delay times for the start of the experimental pressure rise. These times were in good agreement with those obtained from the flame band emission at 3700 A. The data correlated well with the oxygen and methane dependence of Lifshitz, but showed a much stronger temperature dependence (phi = 0.5 delta E = 51.9, phi = 1.0 delta = 58.8, phi = 2.0 delta E = 58.7 Kcal). The effect of probe location on the delay time measurement was studied. It appears that the probe located 83 mm from the reflecting surface measured delay times which may not be related to the initial temperature and pressure. It was estimated that for a probe located 7 mm from the reflecting surface, the measured delay time would be about 10 microseconds too short, and it was suggested that delay times less than 100 microsecond should not be used. The ignition period was defined as the time interval between start of the experimental pressure rise and 50 percent of the ignition pressure. This time interval was measured for three gas mixtures and found to be similar (40 to 60 micro sec) for phi = 1.0 and 0.5 but much longer (100 to 120) microsecond for phi = 2.0. It was suggested that the ignition period would be very useful to the kinetic modeler in judging the agreement between experimental and calculated delay times.

  13. Application of an Entropic Approach to Assessing Systems Integration

    DTIC Science & Technology

    2012-03-01

    two econometrical measures of information efficiency – Shannon entropy and Hurst exponent . Shannon entropy (which is explained in Chapter III) can be...applied to evaluate long-term correlation of time series, while Hurst exponent can be applied to classify the time series in accordance to existence...of trend. Hurst exponent is the statistical measure of time series long-range dependence, and its value falls in the interval [0, 1] – a value in

  14. Assessment of atrial electromechanical interval using echocardiography after catheter ablation in patients with persistent atrial fibrillation.

    PubMed

    Chen, Xiaodong; Chen, Minglong; Wang, Yingying; Yang, Bing; Ju, Weizhu; Zhang, Fengxiang; Cao, Kejiang

    2016-11-01

    We sought to investigate variation of atrial electromechanical interval after catheter ablation procedure in patients with persistent atrial fibrillation using pulse Doppler (PW) and pulse tissue Doppler imaging (PW-TDI). A total of 25 consecutive in-patients with persistent atrial fibrillation, who restored sinus rhythm after ablation procedure, were recruited in our cardiac center. Echocardiography was performed on each patient at 2 hours, 1 day, 5 days, 1 month and 3 months after the ablation therapy, and atrial electromechanical delay was measured simultaneously by PW and PW-TDI. There was no significant difference between PW and TDI in measuring atrial electromechanical delay. However, at postoperative 2 hours, peak A detection rates were mathematically but nonsignificantly greater by PW-TDI than by PW. Second, there was a significant decreasing trend in atrial electromechanical interval from postoperative 2 hours to 3 months, but only postoperative 2-hour atrial electromechanical interval was significantly greater than atrial electromechanical interval at other time. Lastly, patients without postoperative 2-hour atrial electromechanical interval had a significantly longer duration of atrial fibrillation as compared to those with postoperative 2-hour atrial electromechanical interval, by the PW or by PW-TDI, respectively. In patients with persistent atrial fibrillation, atrial electromechanical interval may decrease significantly within the first 24 hours after ablation but remain consistent later, and was significantly related to patients' duration of atrial fibrillation. Atrial electromechanical interval, as a potential predicted factor, is recommended to be measured by either PW or TDI after 24 hours, when patients had recovered sinus rhythm by radiofrequency ablation. © 2016 by the Journal of Biomedical Research. All rights reserved.

  15. A Framework and Algorithms for Multivariate Time Series Analytics (MTSA): Learning, Monitoring, and Recommendation

    ERIC Educational Resources Information Center

    Ngan, Chun-Kit

    2013-01-01

    Making decisions over multivariate time series is an important topic which has gained significant interest in the past decade. A time series is a sequence of data points which are measured and ordered over uniform time intervals. A multivariate time series is a set of multiple, related time series in a particular domain in which domain experts…

  16. Nonuniform sampling and non-Fourier signal processing methods in multidimensional NMR.

    PubMed

    Mobli, Mehdi; Hoch, Jeffrey C

    2014-11-01

    Beginning with the introduction of Fourier Transform NMR by Ernst and Anderson in 1966, time domain measurement of the impulse response (the free induction decay, FID) consisted of sampling the signal at a series of discrete intervals. For compatibility with the discrete Fourier transform (DFT), the intervals are kept uniform, and the Nyquist theorem dictates the largest value of the interval sufficient to avoid aliasing. With the proposal by Jeener of parametric sampling along an indirect time dimension, extension to multidimensional experiments employed the same sampling techniques used in one dimension, similarly subject to the Nyquist condition and suitable for processing via the discrete Fourier transform. The challenges of obtaining high-resolution spectral estimates from short data records using the DFT were already well understood, however. Despite techniques such as linear prediction extrapolation, the achievable resolution in the indirect dimensions is limited by practical constraints on measuring time. The advent of non-Fourier methods of spectrum analysis capable of processing nonuniformly sampled data has led to an explosion in the development of novel sampling strategies that avoid the limits on resolution and measurement time imposed by uniform sampling. The first part of this review discusses the many approaches to data sampling in multidimensional NMR, the second part highlights commonly used methods for signal processing of such data, and the review concludes with a discussion of other approaches to speeding up data acquisition in NMR. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Perioperative Temperature Measurement Considerations Relevant to Reporting Requirements for National Quality Programs Using Data From Anesthesia Information Management Systems.

    PubMed

    Epstein, Richard H; Dexter, Franklin; Hofer, Ira S; Rodriguez, Luis I; Schwenk, Eric S; Maga, Joni M; Hindman, Bradley J

    2018-02-01

    Perioperative hypothermia may increase the incidences of wound infection, blood loss, transfusion, and cardiac morbidity. US national quality programs for perioperative normothermia specify the presence of at least 1 "body temperature" ≥35.5°C during the interval from 30 minutes before to 15 minutes after the anesthesia end time. Using data from 4 academic hospitals, we evaluated timing and measurement considerations relevant to the current requirements to guide hospitals wishing to report perioperative temperature measures using electronic data sources. Anesthesia information management system databases from 4 hospitals were queried to obtain intraoperative temperatures and intervals to the anesthesia end time from discontinuation of temperature monitoring, end of surgery, and extubation. Inclusion criteria included age >16 years, use of a tracheal tube or supraglottic airway, and case duration ≥60 minutes. The end-of-case temperature was determined as the maximum intraoperative temperature recorded within 30 minutes before the anesthesia end time (ie, the temperature that would be used for reporting purposes). The fractions of cases with intervals >30 minutes between the last intraoperative temperature and the anesthesia end time were determined. Among the hospitals, averages (binned by quarters) of 34.5% to 59.5% of cases had intraoperative temperature monitoring discontinued >30 minutes before the anesthesia end time. Even if temperature measurement had been continued until extubation, averages of 5.9% to 20.8% of cases would have exceeded the allowed 30-minute window. Averages of 8.9% to 21.3% of cases had end-of-case intraoperative temperatures <35.5°C (ie, a quality measure failure). Because of timing considerations, a substantial fraction of cases would have been ineligible to use the end-of-case intraoperative temperature for national quality program reporting. Thus, retrieval of postanesthesia care unit temperatures would have been necessary. A substantive percentage of cases had end-of-case intraoperative temperatures below the 35.5°C threshold, also requiring postoperative measurement to determine whether the quality measure was satisfied. Institutions considering reporting national quality measures for perioperative normothermia should consider the technical and logistical issues identified to achieve a high level of compliance based on the specified regulatory language.

  18. Behaviour of a series of reservoirs separated by drowned gates

    NASA Astrophysics Data System (ADS)

    Kolechkina, Alla; van Nooijen, Ronald

    2017-04-01

    Modern control systems tend to be based on computers and therefore to operate by sending commands to structures at given intervals (discrete time control system). Moreover, for almost all water management control systems there are practical lower limits on the time interval between structure adjustments and even between measurements. The water resource systems that are being controlled are physical systems whose state changes continuously. If we combine a continuously changing system and a discrete time controller we get a hybrid system. We use material from recent control theory literature to examine the behaviour of a series of reservoirs separated by drowned gates where the gates are under computer control.

  19. Techniques for measuring arrival times of pulsar signals 1: DSN observations from 1968 to 1980

    NASA Technical Reports Server (NTRS)

    Downs, G. S.; Reichley, P. E.

    1980-01-01

    Techniques used in the ground based observations of pulsars are described, many of them applicable in a navigation scheme. The arrival times of the pulses intercepting Earth are measured at time intervals from a few days to a few months. Low noise, wide band receivers, amplify signals intercepted by 26 m, 34, and 64 m antennas. Digital recordings of total received signal power versus time are cross correlated with the appropriate pulse template.

  20. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility.

    PubMed

    Dirnberger, Johannes; Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-04-01

    The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48-72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTD peak ) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0-30 to 0-300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTD peak (version II). High ICC-values (0.80-0.99) and acceptable CV-values (1.9-8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTD peak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse 0-30ms and RTD/impulse 0-50ms ) showed clearly weaker reproducibility results (ICC: 0.53-0.84; CV: 7.3-16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTD peak -trial.

  1. Time Perception and Depressive Realism: Judgment Type, Psychophysical Functions and Bias

    PubMed Central

    Kornbrot, Diana E.; Msetfi, Rachel M.; Grimwood, Melvyn J.

    2013-01-01

    The effect of mild depression on time estimation and production was investigated. Participants made both magnitude estimation and magnitude production judgments for five time intervals (specified in seconds) from 3 sec to 65 sec. The parameters of the best fitting psychophysical function (power law exponent, intercept, and threshold) were determined individually for each participant in every condition. There were no significant effects of mood (high BDI, low BDI) or judgment (estimation, production) on the mean exponent, n = .98, 95% confidence interval (.96–1.04) or on the threshold. However, the intercept showed a ‘depressive realism’ effect, where high BDI participants had a smaller deviation from accuracy and a smaller difference between estimation and judgment than low BDI participants. Accuracy bias was assessed using three measures of accuracy: difference, defined as psychological time minus physical time, ratio, defined as psychological time divided by physical time, and a new logarithmic accuracy measure defined as ln (ratio). The ln (ratio) measure was shown to have approximately normal residuals when subjected to a mixed ANOVA with mood as a between groups explanatory factor and judgment and time category as repeated measures explanatory factors. The residuals of the other two accuracy measures flagrantly violated normality. The mixed ANOVAs of accuracy also showed a strong depressive realism effect, just like the intercepts of the psychophysical functions. There was also a strong negative correlation between estimation and production judgments. Taken together these findings support a clock model of time estimation, combined with additional cognitive mechanisms to account for the depressive realism effect. The findings also suggest strong methodological recommendations. PMID:23990960

  2. Increasing sensitivity in the measurement of heart rate variability: the method of non-stationary RR time-frequency analysis.

    PubMed

    Melkonian, D; Korner, A; Meares, R; Bahramali, H

    2012-10-01

    A novel method of the time-frequency analysis of non-stationary heart rate variability (HRV) is developed which introduces the fragmentary spectrum as a measure that brings together the frequency content, timing and duration of HRV segments. The fragmentary spectrum is calculated by the similar basis function algorithm. This numerical tool of the time to frequency and frequency to time Fourier transformations accepts both uniform and non-uniform sampling intervals, and is applicable to signal segments of arbitrary length. Once the fragmentary spectrum is calculated, the inverse transform recovers the original signal and reveals accuracy of spectral estimates. Numerical experiments show that discontinuities at the boundaries of the succession of inter-beat intervals can cause unacceptable distortions of the spectral estimates. We have developed a measure that we call the "RR deltagram" as a form of the HRV data that minimises spectral errors. The analysis of the experimental HRV data from real-life and controlled breathing conditions suggests transient oscillatory components as functionally meaningful elements of highly complex and irregular patterns of HRV. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. Real time heart rate variability assessment from Android smartphone camera photoplethysmography: Postural and device influences.

    PubMed

    Guede-Fernandez, F; Ferrer-Mileo, V; Ramos-Castro, J; Fernandez-Chimeno, M; Garcia-Gonzalez, M A

    2015-01-01

    The aim of this paper is to present a smartphone based system for real-time pulse-to-pulse (PP) interval time series acquisition by frame-to-frame camera image processing. The developed smartphone application acquires image frames from built-in rear-camera at the maximum available rate (30 Hz) and the smartphone GPU has been used by Renderscript API for high performance frame-by-frame image acquisition and computing in order to obtain PPG signal and PP interval time series. The relative error of mean heart rate is negligible. In addition, measurement posture and the employed smartphone model influences on the beat-to-beat error measurement of heart rate and HRV indices have been analyzed. Then, the standard deviation of the beat-to-beat error (SDE) was 7.81 ± 3.81 ms in the worst case. Furthermore, in supine measurement posture, significant device influence on the SDE has been found and the SDE is lower with Samsung S5 than Motorola X. This study can be applied to analyze the reliability of different smartphone models for HRV assessment from real-time Android camera frames processing.

  4. Development of microcontroller based water flow measurement

    NASA Astrophysics Data System (ADS)

    Munir, Muhammad Miftahul; Surachman, Arif; Fathonah, Indra Wahyudin; Billah, Muhammad Aziz; Khairurrijal, Mahfudz, Hernawan; Rimawan, Ririn; Lestari, Slamet

    2015-04-01

    A digital instrument for measuring water flow was developed using an AT89S52 microcontroller, DS1302 real time clock (RTC), and EEPROM for an external memory. The sensor used for probing the current was a propeller that will rotate if immersed in a water flow. After rotating one rotation, the sensor sends one pulse and the number of pulses are counted for a certain time of counting. The measurement data, i.e. the number of pulses per unit time, are converted into water flow velocity (m/s) through a mathematical formula. The microcontroller counts the pulse sent by the sensor and the number of counted pulses are stored into the EEPROM memory. The time interval for counting is provided by the RTC and can be set by the operator. The instrument was tested under various time intervals ranging from 10 to 40 seconds and several standard propellers owned by Experimental Station for Hydraulic Structure and Geotechnics (BHGK), Research Institute for Water Resources (Pusair). Using the same propellers and water flows, it was shown that water flow velocities obtained from the developed digital instrument and those found by the provided analog one are almost similar.

  5. An electrical load measurements dataset of United Kingdom households from a two-year longitudinal study

    PubMed Central

    Murray, David; Stankovic, Lina; Stankovic, Vladimir

    2017-01-01

    Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data. PMID:28055033

  6. An electrical load measurements dataset of United Kingdom households from a two-year longitudinal study

    NASA Astrophysics Data System (ADS)

    Murray, David; Stankovic, Lina; Stankovic, Vladimir

    2017-01-01

    Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.

  7. An electrical load measurements dataset of United Kingdom households from a two-year longitudinal study.

    PubMed

    Murray, David; Stankovic, Lina; Stankovic, Vladimir

    2017-01-05

    Smart meter roll-outs provide easy access to granular meter measurements, enabling advanced energy services, ranging from demand response measures, tailored energy feedback and smart home/building automation. To design such services, train and validate models, access to data that resembles what is expected of smart meters, collected in a real-world setting, is necessary. The REFIT electrical load measurements dataset described in this paper includes whole house aggregate loads and nine individual appliance measurements at 8-second intervals per house, collected continuously over a period of two years from 20 houses. During monitoring, the occupants were conducting their usual routines. At the time of publishing, the dataset has the largest number of houses monitored in the United Kingdom at less than 1-minute intervals over a period greater than one year. The dataset comprises 1,194,958,790 readings, that represent over 250,000 monitored appliance uses. The data is accessible in an easy-to-use comma-separated format, is time-stamped and cleaned to remove invalid measurements, correctly label appliance data and fill in small gaps of missing data.

  8. Do physiotherapy staff record treatment time accurately? An observational study.

    PubMed

    Bagley, Pam; Hudson, Mary; Green, John; Forster, Anne; Young, John

    2009-09-01

    To assess the reliability of duration of treatment time measured by physiotherapy staff in early-stage stroke patients. Comparison of physiotherapy staff's recording of treatment sessions and video recording. Rehabilitation stroke unit in a general hospital. Thirty-nine stroke patients without trunk control or who were unable to stand with an erect trunk without the support of two therapists recruited to a randomized trial evaluating the Oswestry Standing Frame. Twenty-six physiotherapy staff who were involved in patient treatment. Contemporaneous recording by physiotherapy staff of treatment time (in minutes) compared with video recording. Intraclass correlation with 95% confidence interval and the Bland and Altman method for assessing agreement by calculating the mean difference (standard deviation; 95% confidence interval), reliability coefficient and 95% limits of agreement for the differences between the measurements. The mean duration (standard deviation, SD) of treatment time recorded by physiotherapy staff was 32 (11) minutes compared with 25 (9) minutes as evidenced in the video recording. The mean difference (SD) was -6 (9) minutes (95% confidence interval (CI) -9 to -3). The reliability coefficient was 18 minutes and the 95% limits of agreement were -24 to 12 minutes. Intraclass correlation coefficient for agreement between the two methods was 0.50 (95% CI 0.12 to 0.73). Physiotherapy staff's recording of duration of treatment time was not reliable and was systematically greater than the video recording.

  9. Influence of the time scale on the construction of financial networks.

    PubMed

    Emmert-Streib, Frank; Dehmer, Matthias

    2010-09-30

    In this paper we investigate the definition and formation of financial networks. Specifically, we study the influence of the time scale on their construction. For our analysis we use correlation-based networks obtained from the daily closing prices of stock market data. More precisely, we use the stocks that currently comprise the Dow Jones Industrial Average (DJIA) and estimate financial networks where nodes correspond to stocks and edges correspond to none vanishing correlation coefficients. That means only if a correlation coefficient is statistically significant different from zero, we include an edge in the network. This construction procedure results in unweighted, undirected networks. By separating the time series of stock prices in non-overlapping intervals, we obtain one network per interval. The length of these intervals corresponds to the time scale of the data, whose influence on the construction of the networks will be studied in this paper. Numerical analysis of four different measures in dependence on the time scale for the construction of networks allows us to gain insights about the intrinsic time scale of the stock market with respect to a meaningful graph-theoretical analysis.

  10. Best Practices to Achieve the Lowest Uncertainty in Measuring with Respect

    Science.gov Websites

    been sitting in a cabinet from time to time. If control charts are used, then this interval could be 6 packaged cells or module for use in control charts to monitor the test bed and any potential drift in the reference device's calibration. Measure the control sample at least once a week. Plot percentage deviation

  11. Temporal properties of compensation for positive and negative spectacle lenses in chicks.

    PubMed

    Zhu, Xiaoying; Wallman, Josh

    2009-01-01

    Chicks' eyes rapidly compensate for defocus imposed by spectacle lenses by changing their rate of elongation and their choroidal thickness. Compensation may involve internal emmetropization signals that rise and become saturated during episodes of lens wear and decline between episodes. The time constants of these signals were measured indirectly by measuring the magnitude of lens compensation in refractive error and ocular dimensions as a function of the duration of episodes and the intervals between the episodes. First, in a study of how quickly the signals rose, chicks were subjected to episodes of lens-wear of various durations (darkness otherwise), and the duration required to cause a half-maximum effect (rise-time) was estimated. Second, in a study of how quickly the signals declined, various dark intervals were imposed between episodes of lens-wear, and the interval required to reduce the maximum effect by half (fall-time) was estimated. The rise-times for the rate of ocular elongation and choroidal thickness were approximately 3 minutes for positive and negative lenses. The fall-times had a broad range of time courses: Positive lenses caused an enduring inhibition of ocular elongation with a fall-time of 24 hours. In contrast, negative lenses caused a transient stimulation of ocular elongation with a fall-time of 0.4 hour. The effects of episodes of defocus rise rapidly with episode duration to an asymptote and decline between episodes, with the time course depending strongly on the sign of defocus and the ocular component. The complex etiology of human myopia may reflect these temporal properties.

  12. Differential Changes in Myocardial Performance Index and Its Time Intervals in Donors and Recipients of Twin-to-Twin Transfusion Syndrome before and after Laser Therapy.

    PubMed

    Ortiz, Javier U; Torres, Ximena; Eixarch, Elisenda; Bennasar, Mar; Cruz-Lemini, Monica; Gómez, Olga; Lobmaier, Silvia M; Martínez, Josep M; Gratacós, Eduard; Crispi, Fatima

    2018-01-19

    To evaluate left myocardial performance index (MPI) and time intervals in fetuses with twin-to-twin transfusion syndrome (TTTS) before and after laser surgery. Fifty-one fetal pairs with TTTS and 47 uncomplicated monochorionic twin pairs were included. Left ventricular isovolumetric contraction time (ICT), ejection time (ET), and isovolumetric relaxation time (IRT) were measured using conventional Doppler. Recipients showed prolonged ICT (46 ± 12 vs. 31 ± 8 vs. 30 ± 5 ms; p < 0.001) and IRT (51 ± 9 vs. 43 ± 8 vs. 43 ± 5 ms; p < 0.001) and higher MPI (0.57 ± 0.12 vs. 0.47 ± 0.09 vs. 0.44 ± 0.05; p < 0.001) than donors and controls. Donors showed shorter ET than recipients and controls (157 ± 12 vs. 169 ± 10 vs. 168 ± 10 ms; p < 0.001) and higher MPI than controls (0.47 ± 0.09 vs. 0.44 ± 0.05; p = 0.006). Preoperative MPI changes were observed in all TTTS stages. Time intervals partially improved after surgery. Donor and recipient twins had higher MPI due to different changes in the time intervals, possibly reflecting the state of hypovolemia in the donor and hypervolemia and pressure overload in the recipient. © 2018 S. Karger AG, Basel.

  13. The Application of Root Mean Square Electrocardiography (RMS ECG) for the Detection of Acquired and Congenital Long QT Syndrome

    PubMed Central

    Lux, Robert L.; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P.; Tristani-Firouzi, Martin; Saarel, Elizabeth V.

    2014-01-01

    Background Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). Methods RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. Results All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. Conclusion These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements. PMID:24454918

  14. The application of root mean square electrocardiography (RMS ECG) for the detection of acquired and congenital long QT syndrome.

    PubMed

    Lux, Robert L; Sower, Christopher Todd; Allen, Nancy; Etheridge, Susan P; Tristani-Firouzi, Martin; Saarel, Elizabeth V

    2014-01-01

    Precise measurement of the QT interval is often hampered by difficulty determining the end of the low amplitude T wave. Root mean square electrocardiography (RMS ECG) provides a novel alternative measure of ventricular repolarization. Experimental data have shown that the interval between the RMS ECG QRS and T wave peaks (RTPK) closely reflects the mean ventricular action potential duration while the RMS T wave width (TW) tracks the dispersion of repolarization timing. Here, we tested the precision of RMS ECG to assess ventricular repolarization in humans in the setting of drug-induced and congenital Long QT Syndrome (LQTS). RMS ECG signals were derived from high-resolution 24 hour Holter monitor recordings from 68 subjects after receiving placebo and moxifloxacin and from standard 12 lead ECGs obtained in 97 subjects with LQTS and 97 age- and sex-matched controls. RTPK, QTRMS and RMS TW intervals were automatically measured using custom software and compared to traditional QT measures using lead II. All measures of repolarization were prolonged during moxifloxacin administration and in LQTS subjects, but the variance of RMS intervals was significantly smaller than traditional lead II measurements. TW was prolonged during moxifloxacin and in subjects with LQT-2, but not LQT-1 or LQT-3. These data validate the application of RMS ECG for the detection of drug-induced and congenital LQTS. RMS ECG measurements are more precise than the current standard of care lead II measurements.

  15. Measuring Fracture Times Of Ceramics

    NASA Technical Reports Server (NTRS)

    Shlichta, Paul J.; Bister, Leo; Bickler, Donald G.

    1989-01-01

    Electrical measurements complement or replace fast cinematography. Electronic system measures microsecond time intervals between impacts of projectiles on ceramic tiles and fracture tiles. Used in research on ceramics and ceramic-based composite materials such as armor. Hardness and low density of ceramics enable them to disintegrate projectiles more efficiently than metals. Projectile approaches ceramic tile specimen. Penetrating foil squares of triggering device activate display and recording instruments. As ceramic and resistive film break oscilloscope plots increase in electrical resistance of film.

  16. Constructing Proxy Variables to Measure Adult Learners' Time Management Strategies in LMS

    ERIC Educational Resources Information Center

    Jo, Il-Hyun; Kim, Dongho; Yoon, Meehyun

    2015-01-01

    This study describes the process of constructing proxy variables from recorded log data within a Learning Management System (LMS), which represents adult learners' time management strategies in an online course. Based on previous research, three variables of total login time, login frequency, and regularity of login interval were selected as…

  17. Chirped frequency transfer: a tool for synchronization and time transfer.

    PubMed

    Raupach, Sebastian M F; Grosche, Gesine

    2014-06-01

    We propose and demonstrate the phase-stabilized transfer of a chirped frequency as a tool for synchronization and time transfer. Technically, this is done by evaluating remote measurements of the transferred, chirped frequency. The gates of the frequency counters, here driven by a 10-MHz oscillation derived from a hydrogen maser, play a role analogous to the 1-pulse per second (PPS) signals usually employed for time transfer. In general, for time transfer, the gates consequently must be related to the external clock. Synchronizing observations based on frequency measurements, on the other hand, only requires a stable oscillator driving the frequency counters. In a proof of principle, we demonstrate the suppression of symmetrical delays, such as the geometrical path delay. We transfer an optical frequency chirped by around 240 kHz/s over a fiber link of around 149 km. We observe an accuracy and simultaneity, as well as a precision (Allan deviation, 18,000 s averaging interval) of the transferred frequency of around 2 × 10(-19). We apply chirped frequency transfer to remote measurements of the synchronization between two counters' gate intervals. Here, we find a precision of around 200 ps at an estimated overall uncertainty of around 500 ps. The measurement results agree with those obtained from reference measurements, being well within the uncertainty. In the present setup, timing offsets up to 4 min can be measured unambiguously. We indicate how this range can be extended further.

  18. High frequency, high time resolution time-to-digital converter employing passive resonating circuits.

    PubMed

    Ripamonti, Giancarlo; Abba, Andrea; Geraci, Angelo

    2010-05-01

    A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

  19. Effect of timing of relocation of replacement gilts from group pens to individual stalls before breeding on fertility and well-being.

    PubMed

    Knox, R V; Shen, J; Greiner, L L; Connor, J F

    2016-12-01

    Variation in gilt fertility is associated with increased replacement and reduced longevity. Stress before breeding is hypothesized to be involved in reduced fertility. This study tested the timing of gilt relocation from pens to individual stalls before breeding on fertility and well-being. The experiment was performed in replicates on a commercial research farm. After detection of first estrus, gilts ( = 563) were assigned to treatment for relocation into stalls 3 wk (REL3wk), 2 wk (REL2wk), or 1 wk (REL1wk) before breeding at second estrus. Subsets of gilts from each treatment ( = 60) were selected for assessment of follicles at second estrus. Data included interestrus interval, number of services, conception, farrowing, total born, and wean to service interval. Piglet birth weight was obtained on subsets of litters ( = 42/treatment). Measures of well-being included BW, backfat, BCS, lesions, and lameness from wk 1 after first estrus until wk 16. Gilt BW at wk 5 (158.4 kg) was not affected ( > 0.10) by treatment. Measures of BCS, lameness, and lesions at breeding and throughout gestation did not differ ( > 0.10). Treatment did not affect ( > 0.10) gilts expressing a normal interestrus interval of 18 to 24 d (83.4%) but did influence ( < 0.05) the proportion expressing shorter ( < 0.001) and longer ( < 0.001) intervals. Gilts in REL3wk had a shorter ( < 0.001) interestrus interval (20.7 d) than those in REL2wk and REL1wk (22.6 d). Gilts with shorter intervals ( = 24) had fewer total born while gilts expressing longer cycles ( = 65) had reduced farrowing rates. The number of services (1.9) and number of follicles (19.7) at breeding were not affected ( > 0.10) by relocation. There was no effect of treatment on farrowing rate (85.2%), born alive (12.6), or any litter birth weight measures ( > 0.10). The percentage of sows bred within 7 d after weaning (94.4%) was also not affected by treatment ( > 0.10). These results suggest that the timing of relocation before breeding had no effect on well-being or on the majority of gilts with normal estrous cycles and their subsequent fertility. However, a smaller proportion of the gilts exhibited shorter and longer interestrus intervals in response to relocation 1 or 3 wk before breeding. In cases where gilt fertility may be less than optimal, producers that relocate gilts from pens to stalls before breeding should evaluate interestrus interval as a response criterion.

  20. Measures of native and non-native rhythm in a quantity language.

    PubMed

    Stockmal, Verna; Markus, Dace; Bond, Dzintra

    2005-01-01

    The traditional phonetic classification of language rhythm as stress-timed or syllable-timed is attributed to Pike. Recently, two different proposals have been offered for describing the rhythmic structure of languages from acoustic-phonetic measurements. Ramus has suggested a metric based on the proportion of vocalic intervals and the variability (SD) of consonantal intervals. Grabe has proposed Pairwise Variability Indices (nPVI, rPVI) calculated from the differences in vocalic and consonantal durations between successive syllables. We have calculated both the Ramus and Grabe metrics for Latvian, traditionally considered a syllable rhythm language, and for Latvian as spoken by Russian learners. Native speakers and proficient learners were very similar whereas low-proficiency learners showed high variability on some properties. The metrics did not provide an unambiguous classification of Latvian.

  1. The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czarski, T., E-mail: tomasz.czarski@ifpilm.pl; Chernyshova, M.; Malinowski, K.

    2016-11-15

    The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals,more » and cluster charge values corresponding to the energy spectra.« less

  2. Postextrasystolic potentiation and contractile reserve: requirements and restrictions.

    PubMed

    Lust, R M; Lutherer, L O; Gardner, M E; Cooper, M W

    1982-12-01

    These studies were conducted to examine the basic characteristics of postextrasystolic potentiation (PESP) and the relationship of loading effects to PESP. Measurements of left ventricular (LV) and aortic pressures, the rate of pressure rise, and echocardiographically determined LV dimensions were made in anesthetized open-chest dogs. The hearts were paced, and timed extrasystoles were introduced that were followed by postextrasystoles (PES). PES's were elicited after an interval equal to either a full compensatory pause or a time when the diastolic properties of the LV could not be distinguished from control (isolength). Potentiation of contraction for the PES's introduced after an isolength pause was dependent on both the heart rate and the extrasystolic interval, whereas the PES's that occurred after a full pause showed no dependence on either of these intervals. PESP elicited during the isolength period was not dependent on either preload and afterload. It is concluded that PESP depends on the combination of heart rate and extrasystolic and postextrasystolic intervals. Further, PESP may be inaccurate in assessing contractile reserve unless the heart rate and extrasystolic interval are known and the PES is introduced after an isolength pause.

  3. 40 CFR Appendix D to Part 52 - Determination of Sulfur Dioxide Emissions From Stationary Sources by Continuous Monitors

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean value... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean and... operation when the pollutant concentration at the time for the measurement is zero. 1.6Calibration Drift...

  4. 40 CFR Appendix D to Part 52 - Determination of Sulfur Dioxide Emissions From Stationary Sources by Continuous Monitors

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean value... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean and... operation when the pollutant concentration at the time for the measurement is zero. 1.6Calibration Drift...

  5. 40 CFR Appendix D to Part 52 - Determination of Sulfur Dioxide Emissions From Stationary Sources by Continuous Monitors

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean value... confidence interval using Equations D-1 and D-2. Report the zero drift as the sum of the absolute mean and... operation when the pollutant concentration at the time for the measurement is zero. 1.6Calibration Drift...

  6. Evaluation of emergency department performance - a systematic review on recommended performance and quality-in-care measures.

    PubMed

    Sørup, Christian Michel; Jacobsen, Peter; Forberg, Jakob Lundager

    2013-08-09

    Evaluation of emergency department (ED) performance remains a difficult task due to the lack of consensus on performance measures that reflects high quality, efficiency, and sustainability. To describe, map, and critically evaluate which performance measures that the published literature regard as being most relevant in assessing overall ED performance. Following the PRISMA guidelines, a systematic literature review of review articles reporting accentuated ED performance measures was conducted in the databases of PubMed, Cochrane Library, and Web of Science. Study eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. A number of articles addresses this study's objective (n = 14 of 46 unique hits). Time intervals and patient-related measures were dominant in the identified performance measures in review articles from US, UK, Sweden and Canada. Length of stay (LOS), time between patient arrival to initial clinical assessment, and time between patient arrivals to admission were highlighted by the majority of articles. Concurrently, "patients left without being seen" (LWBS), unplanned re-attendance within a maximum of 72 hours, mortality/morbidity, and number of unintended incidents were the most highlighted performance measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study's results allow for advancement towards improved performance measurement and standardised assessment across EDs.

  7. A systematic review and meta-analysis of carbohydrate benefits associated with randomized controlled competition-based performance trials.

    PubMed

    Pöchmüller, Martin; Schwingshackl, Lukas; Colombani, Paolo C; Hoffmann, Georg

    2016-01-01

    Carbohydrate supplements are widely used by athletes as an ergogenic aid before and during sports events. The present systematic review and meta-analysis aimed at synthesizing all available data from randomized controlled trials performed under real-life conditions. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were searched systematically up to February 2015. Study groups were categorized according to test mode and type of performance measurement. Subgroup analyses were done with reference to exercise duration and range of carbohydrate concentration. Random effects and fixed effect meta-analyses were performed using the Software package by the Cochrane Collaboration Review Manager 5.3. Twenty-four randomized controlled trials met the objectives and were included in the present systematic review, 16 of which provided data for meta-analyses. Carbohydrate supplementations were associated with a significantly shorter exercise time in groups performing submaximal exercise followed by a time trial [mean difference -0.9 min (95 % confidence interval -1.7, -0.2), p = 0.02] as compared to controls. Subgroup analysis showed that improvements were specific for studies administering a concentration of carbohydrates between 6 and 8 % [mean difference -1.0 min (95 % confidence interval -1.9, -0.0), p = 0.04]. Concerning groups with submaximal exercise followed by a time trial measuring power accomplished within a fixed time or distance, mean power output was significantly higher following carbohydrate load (mean difference 20.2 W (95 % confidence interval 9.0, 31.5), p = 0.0004]. Likewise, mean power output was significantly increased following carbohydrate intervention in groups with time trial measuring power within a fixed time or distance (mean difference 8.1 W (95 % confidence interval 0.5, 15.7) p = 0.04]. Due to the limitations of this systematic review, results can only be applied to a subset of athletes (trained male cyclists). For those, we could observe a potential ergogenic benefit of carbohydrate supplementation especially in a concentration range between 6 and 8 % when exercising longer than 90 min.

  8. Impact of a radio frequency management information system on the process and timing of providing respiratory care services.

    PubMed

    Stoller, James K; Kester, Lucy; Orens, Douglas K; McCarthy, Kevin

    2002-08-01

    Although radio frequency (RF) systems have proliferated and are designed to simplify care delivery in many clinical settings, little information is available on the impact of such RF systems on the delivery of patient care. Having used a hand-held-device-based management information system in our Respiratory Therapy Section for 16 years, we assessed the impact of an RF system on the delivery of respiratory therapy (RT) services. A single nursing unit dedicated to pulmonary and ear, nose, and throat care was selected for the RF system trial. Baseline (pre-RF) data were collected over 2 separate 1-month intervals (February 1999 and February 2000). The main outcome measures were (1) the amount of time needed at the beginning of the shift to organize and assign orders for RT services, (2) the time interval between notification of an RT consult order and completion of the RT consult, and (3) the time interval between notification of an RT treatment order and completion of the RT treatment. The activities required for organizing and assigning the orders were manually timed. Starting 6 weeks after therapists were trained to use the RF system, similar data were collected while using the RF system for two 1-month intervals (February and March 2001). The mean +/- SD time interval between receiving an RT consult order and completing the consult was reduced from 7.8 +/- 18.9 h to 2.8 +/- 2.4 h (p = 0.002). The percentage of patients who waited longer than 8 hours between receipt of a consult order and completion of the consult decreased from 18% to 4.7% (p = 0.026). The total time required for organizing and assigning RT work was reduced from 81.6 min to 43.6 min. The RF system had several advantages over the hand-held-device-based system: (1) shorter interval between the order for and completion of an RT consult, (2) lower percentage of patients for whom the interval between the order and the consult exceeded 8 hours, and (3) less time required to make shift assignments. These results invite assessment of whether accelerated delivery of RT services confers clinical benefits.

  9. Data system for multiplexed water-current meters

    NASA Technical Reports Server (NTRS)

    Ramsey, C. R.

    1977-01-01

    Flow rates at 32 flood plain locations are measured simultaneously by single digital logic unit with high noise immunity. Water flowing through pygmy current meters rotates element that closes electrical contact once every resolution, so flow rate is measured by counting number of closures in time interval.

  10. Smoked marijuana effects on tobacco cigarette smoking behavior.

    PubMed

    Kelly, T H; Foltin, R W; Rose, A J; Fischman, M W; Brady, J V

    1990-03-01

    The effects of marijuana smoke exposure on several measures of tobacco cigarette smoking behavior were examined. Eight healthy adult male volunteers, who smoked both tobacco and marijuana cigarettes, participated in residential studies, lasting 10 to 15 days, designed to measure the effects of marijuana smoke exposure on a range of behavioral variables. Tobacco cigarettes were available throughout the day (9:00 A.M. until midnight). Each day was divided into a private period (9:00 A.M. to 5:00 P.M.), during which subjects were socially isolated, and a social period (5:00 P.M. to midnight), during which subjects could interact. Under blind conditions, subjects smoked placebo and active marijuana cigarettes (0%, 1.3%, 2.3%, or 2.7% delta 9-tetrahydrocannabinol) four times daily (9:45 A.M., 1:30 P.M., 5:00 P.M. and 8:30 P.M.). Each subject was exposed to both placebo and one active dose over 2- to 5-consecutive-day intervals, and dose conditions (i.e., placebo or active) alternated throughout the study. Active marijuana smoking significantly decreased the number of daily tobacco smoking bouts, increased inter-bout intervals and decreased inter-puff intervals. Marijuana decreased the number of tobacco smoking bouts by delaying the initiation of tobacco cigarette smoking immediately after marijuana smoking, whereas decreases in inter-puff intervals were unrelated to the time of marijuana smoking. No consistent interactions between marijuana effects and social or private periods (i.e., time of day) were observed.

  11. Quantifying the statistical complexity of low-frequency fluctuations in semiconductor lasers with optical feedback

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tiana-Alsina, J.; Torrent, M. C.; Masoller, C.

    Low-frequency fluctuations (LFFs) represent a dynamical instability that occurs in semiconductor lasers when they are operated near the lasing threshold and subject to moderate optical feedback. LFFs consist of sudden power dropouts followed by gradual, stepwise recoveries. We analyze experimental time series of intensity dropouts and quantify the complexity of the underlying dynamics employing two tools from information theory, namely, Shannon's entropy and the Martin, Plastino, and Rosso statistical complexity measure. These measures are computed using a method based on ordinal patterns, by which the relative length and ordering of consecutive interdropout intervals (i.e., the time intervals between consecutive intensitymore » dropouts) are analyzed, disregarding the precise timing of the dropouts and the absolute durations of the interdropout intervals. We show that this methodology is suitable for quantifying subtle characteristics of the LFFs, and in particular the transition to fully developed chaos that takes place when the laser's pump current is increased. Our method shows that the statistical complexity of the laser does not increase continuously with the pump current, but levels off before reaching the coherence collapse regime. This behavior coincides with that of the first- and second-order correlations of the interdropout intervals, suggesting that these correlations, and not the chaotic behavior, are what determine the level of complexity of the laser's dynamics. These results hold for two different dynamical regimes, namely, sustained LFFs and coexistence between LFFs and steady-state emission.« less

  12. The synchronisation of lower limb responses with a variable metronome: the effect of biomechanical constraints on timing.

    PubMed

    Chen, Hui-Ya; Wing, Alan M; Pratt, David

    2006-04-01

    Stepping in time with a metronome has been reported to improve pathological gait. Although there have been many studies of finger tapping synchronisation tasks with a metronome, the specific details of the influences of metronome timing on walking remain unknown. As a preliminary to studying pathological control of gait timing, we designed an experiment with four synchronisation tasks, unilateral heel tapping in sitting, bilateral heel tapping in sitting, bilateral heel tapping in standing, and stepping on the spot, in order to examine the influence of biomechanical constraints on metronome timing. These four conditions allow study of the effects of bilateral co-ordination and maintenance of balance on timing. Eight neurologically normal participants made heel tapping and stepping responses in synchrony with a metronome producing 500 ms interpulse intervals. In each trial comprising 40 intervals, one interval, selected at random between intervals 15 and 30, was lengthened or shortened, which resulted in a shift in phase of all subsequent metronome pulses. Performance measures were the speed of compensation for the phase shift, in terms of the temporal difference between the response and the metronome pulse, i.e. asynchrony, and the standard deviation of the asynchronies and interresponse intervals of steady state synchronisation. The speed of compensation decreased with increase in the demands of maintaining balance. The standard deviation varied across conditions but was not related to the compensation speed. The implications of these findings for metronome assisted gait are discussed in terms of a first-order linear correction account of synchronisation.

  13. Radiographic angles in hallux valgus: Comparison between protractor and iPhone measurements.

    PubMed

    Meng, Hong-Zheng; Zhang, Wei-Lin; Li, Xiu-Cheng; Yang, Mao-Wei

    2015-08-01

    Radiographic angles are used to assess the severity of hallux valgus deformity, make preoperative plans, evaluate outcomes after surgery, and compare results between different methods. Traditionally, hallux valgus angle (HVA) has been measured by using a protractor and a marker pen with hardcopy radiographs. The main objective of this study is to compare HVA measurements performed using a smartphone and a traditional protractor. The secondary objective was to compare the time taken between those two methods. Six observers measured major HVA on 20 radiographs of hallux valgus deformity with both a standard protractor and an Apple iPhone. Four of the observers repeated the measurements at least a week after the original measurements. The mean absolute difference between pairs of protractor and smartphone measurements was 3.2°. The 95% confidence intervals for intra-observer variability were ±3.1° for the smartphone measurement and ±3.2° for the protractor method. The 95% confidence intervals for inter-observer variability were ±9.1° for the smartphone measurement and ±9.6° for the protractor measurement. We conclude that the smartphone is equivalent to the protractor for the accuracy of HVA measurement. But, the time taken in smartphone measurement was also reduced. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  14. Feeding Intervals in Premature Infants ≤1750 g: An Integrative Review.

    PubMed

    Binchy, Áine; Moore, Zena; Patton, Declan

    2018-06-01

    The timely establishment of enteral feeds and a reduction in the number of feeding interruptions are key to achieving optimal nutrition in premature infants. Nutritional guidelines vary widely regarding feeding regimens and there is not a widely accepted consensus on the optimal feeding interval. To critically examine the evidence to determine whether there is a relationship to feeding intervals and feeding outcomes in premature infants. A systematic review of the literature in the following databases: PubMed, CINAHL, Embase and the Cochrane Library. The search strategy used the terms infant premature, low birth weight, enteral feeding, feed tolerance and feed intervals. Search results yielded 10 studies involving 1269 infants (birth weight ≤1750 g). No significant differences in feed intolerance, growth, or incidence of necrotizing enterocolitis were observed. Evidence suggests that infants fed at 2 hourly intervals reached full feeds faster than at 3 hourly intervals, had fewer days on parenteral nutrition, and fewer days in which feedings were withheld. Decrease in the volume of gastric residuals and feeding interruptions were observed in the infants fed at 3 hourly intervals than those who were continuously fed. Reducing the feed interval from 3 to 2 hourly increases nurse workload, yet may improve feeding outcomes by reducing the time to achieve full enteral feeding. Studies varied greatly in the definition and management of feeding intolerance and in how outcomes were measured, analyzed, and reported. The term "intermittent" is used widely but can refer to a 2 or 3 hourly interval.

  15. Technical note: Instantaneous sampling intervals validated from continuous video observation for behavioral recording of feedlot lambs.

    PubMed

    Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L

    2017-11-01

    When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.

  16. The optimized V-V interval determined by interventricular conduction times versus invasive measurement by LVdP/dtMAX.

    PubMed

    van Gelder, Berry M; Meijer, Albert; Bracke, Frank A

    2008-09-01

    We compared the calculated optimal V-V interval derived from intracardiac electrograms (IEGM) with the optimized V-V interval determined by invasive measurement of LVdP/dt(MAX). Thirty-two patients with heart failure (six females, ages 68 +/- 7.8 years) had a CRT device implanted. After implantation of the atrial, right and a left ventricular lead, the optimal V-V interval was calculated using the QuickOpt formula (St. Jude Medical, Sylmar, CA, USA) applied to the respective IEGM recordings (V-V(IEGM)), and also determined by invasive measurement of LVdP/dt(MAX) (V-V(dP/dt)). The optimal V-V(IEGM) and V-V(dP/dt) intervals were 52.7 +/- 18 ms and 24.0 +/- 33 ms, respectively (P = 0.017), without correlation between the two. The baseline LVdP/dt(MAX) was 748 +/- 191 mmHg/s. The mean value of LVdP/dt(MAX) at invasive optimization was 947 +/- 198 mmHg/s, and at the calculated optimal V-V(IEGM) interval 920 +/- 191 mmHg/s (P < 0.0001). In spite of this significant difference, there was a good correlation between both methods (R = 0.991, P < 0.0001). However, a similarly good correlation existed between the maximum value of LVdP/dt(MAX) and LVdP/dt(MAX) at a fixed V-V interval of 0 ms (R = 0.993, P < 0.0001), or LVdP/dt(MAX) at a randomly selected V-V interval between 0 and +80 ms (R = 0.991, P < 0.0001). Optimizing the V-V interval with the IEGM method does not yield better hemodynamic results than simultaneous BiV pacing. Although a good correlation between LVdP/dt(MAX) determined with V-V(IEGM) and V-V(dP/dt) can be constructed, there is no correlation with the optimal settings of V-V interval in the individual patient.

  17. An inventory-theory-based interval-parameter two-stage stochastic programming model for water resources management

    NASA Astrophysics Data System (ADS)

    Suo, M. Q.; Li, Y. P.; Huang, G. H.

    2011-09-01

    In this study, an inventory-theory-based interval-parameter two-stage stochastic programming (IB-ITSP) model is proposed through integrating inventory theory into an interval-parameter two-stage stochastic optimization framework. This method can not only address system uncertainties with complex presentation but also reflect transferring batch (the transferring quantity at once) and period (the corresponding cycle time) in decision making problems. A case of water allocation problems in water resources management planning is studied to demonstrate the applicability of this method. Under different flow levels, different transferring measures are generated by this method when the promised water cannot be met. Moreover, interval solutions associated with different transferring costs also have been provided. They can be used for generating decision alternatives and thus help water resources managers to identify desired policies. Compared with the ITSP method, the IB-ITSP model can provide a positive measure for solving water shortage problems and afford useful information for decision makers under uncertainty.

  18. Earth before life.

    PubMed

    Marzban, Caren; Viswanathan, Raju; Yurtsever, Ulvi

    2014-01-09

    A recent study argued, based on data on functional genome size of major phyla, that there is evidence life may have originated significantly prior to the formation of the Earth. Here a more refined regression analysis is performed in which 1) measurement error is systematically taken into account, and 2) interval estimates (e.g., confidence or prediction intervals) are produced. It is shown that such models for which the interval estimate for the time origin of the genome includes the age of the Earth are consistent with observed data. The appearance of life after the formation of the Earth is consistent with the data set under examination.

  19. Setting Thresholds to Varying Blood Pressure Monitoring Intervals Differentially Affects Risk Estimates Associated With White-Coat and Masked Hypertension in the Population

    PubMed Central

    Asayama, Kei; Thijs, Lutgarde; Li, Yan; Gu, Yu-Mei; Hara, Azusa; Liu, Yan-Ping; Zhang, Zhenyu; Wei, Fang-Fei; Lujambio, Inés; Mena, Luis J.; Boggia, José; Hansen, Tine W.; Björklund-Bodegård, Kristina; Nomura, Kyoko; Ohkubo, Takayoshi; Jeppesen, Jørgen; Torp-Pedersen, Christian; Dolan, Eamon; Stolarz-Skrzypek, Katarzyna; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Luzardo, Leonella; Kawecka-Jaszcz, Kalina; Sandoya, Edgardo; Filipovský, Jan; Maestre, Gladys E.; Wang, Jiguang; Imai, Yutaka; Franklin, Stanley S.; O’Brien, Eoin; Staessen, Jan A.

    2015-01-01

    Outcome-driven recommendations about time intervals during which ambulatory blood pressure should be measured to diagnose white-coat or masked hypertension are lacking. We cross-classified 8237 untreated participants (mean age, 50.7 years; 48.4% women) enrolled in 12 population studies, using ≥140/≥90, ≥130/≥80, ≥135/≥85, and ≥120/≥70 mm Hg as hypertension thresholds for conventional, 24-hour, daytime, and nighttime blood pressure. White-coat hypertension was hypertension on conventional measurement with ambulatory normotension, the opposite condition being masked hypertension. Intervals used for classification of participants were daytime, nighttime, and 24 hours, first considered separately, and next combined as 24 hours plus daytime or plus nighttime, or plus both. Depending on time intervals chosen, white-coat and masked hypertension frequencies ranged from 6.3% to 12.5% and from 9.7% to 19.6%, respectively. During 91 046 person-years, 729 participants experienced a cardiovascular event. In multivariable analyses with normotension during all intervals of the day as reference, hazard ratios associated with white-coat hypertension progressively weakened considering daytime only (1.38; P=0.033), nighttime only (1.43; P=0.0074), 24 hours only (1.21; P=0.20), 24 hours plus daytime (1.24; P=0.18), 24 hours plus nighttime (1.15; P=0.39), and 24 hours plus daytime and nighttime (1.16; P=0.41). The hazard ratios comparing masked hypertension with normotension were all significant (P<0.0001), ranging from 1.76 to 2.03. In conclusion, identification of truly low-risk white-coat hypertension requires setting thresholds simultaneously to 24 hours, daytime, and nighttime blood pressure. Although any time interval suffices to diagnose masked hypertension, as proposed in current guidelines, full 24-hour recordings remain standard in clinical practice. PMID:25135185

  20. Statistical evaluation of time-dependent metabolite concentrations: estimation of post-mortem intervals based on in situ 1H-MRS of the brain.

    PubMed

    Scheurer, Eva; Ith, Michael; Dietrich, Daniel; Kreis, Roland; Hüsler, Jürg; Dirnhofer, Richard; Boesch, Chris

    2005-05-01

    Knowledge of the time interval from death (post-mortem interval, PMI) has an enormous legal, criminological and psychological impact. Aiming to find an objective method for the determination of PMIs in forensic medicine, 1H-MR spectroscopy (1H-MRS) was used in a sheep head model to follow changes in brain metabolite concentrations after death. Following the characterization of newly observed metabolites (Ith et al., Magn. Reson. Med. 2002; 5: 915-920), the full set of acquired spectra was analyzed statistically to provide a quantitative estimation of PMIs with their respective confidence limits. In a first step, analytical mathematical functions are proposed to describe the time courses of 10 metabolites in the decomposing brain up to 3 weeks post-mortem. Subsequently, the inverted functions are used to predict PMIs based on the measured metabolite concentrations. Individual PMIs calculated from five different metabolites are then pooled, being weighted by their inverse variances. The predicted PMIs from all individual examinations in the sheep model are compared with known true times. In addition, four human cases with forensically estimated PMIs are compared with predictions based on single in situ MRS measurements. Interpretation of the individual sheep examinations gave a good correlation up to 250 h post-mortem, demonstrating that the predicted PMIs are consistent with the data used to generate the model. Comparison of the estimated PMIs with the forensically determined PMIs in the four human cases shows an adequate correlation. Current PMI estimations based on forensic methods typically suffer from uncertainties in the order of days to weeks without mathematically defined confidence information. In turn, a single 1H-MRS measurement of brain tissue in situ results in PMIs with defined and favorable confidence intervals in the range of hours, thus offering a quantitative and objective method for the determination of PMIs. Copyright 2004 John Wiley & Sons, Ltd.

  1. Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation.

    PubMed

    Ding, Xiaorong; Zhang, Yuanting; Tsang, Hon Ki

    2016-02-01

    Continuous blood pressure (BP) measurement without a cuff is advantageous for the early detection and prevention of hypertension. The pulse transit time (PTT) method has proven to be promising for continuous cuffless BP measurement. However, the problem of accuracy is one of the most challenging aspects before the large-scale clinical application of this method. Since PTT-based BP estimation relies primarily on the relationship between PTT and BP under certain assumptions, estimation accuracy will be affected by cardiovascular disorders that impair this relationship and by the calibration frequency, which may violate these assumptions. This study sought to examine the impact of heart disease and the calibration interval on the accuracy of PTT-based BP estimation. The accuracy of a PTT-BP algorithm was investigated in 37 healthy subjects and 48 patients with heart disease at different calibration intervals, namely 15 min, 2 weeks, and 1 month after initial calibration. The results showed that the overall accuracy of systolic BP estimation was significantly lower in subjects with heart disease than in healthy subjects, but diastolic BP estimation was more accurate in patients than in healthy subjects. The accuracy of systolic and diastolic BP estimation becomes less reliable with longer calibration intervals. These findings demonstrate that both heart disease and the calibration interval can influence the accuracy of PTT-based BP estimation and should be taken into consideration to improve estimation accuracy.

  2. Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics

    NASA Technical Reports Server (NTRS)

    Iyengar, N.; Peng, C. K.; Morin, R.; Goldberger, A. L.; Lipsitz, L. A.

    1996-01-01

    We postulated that aging is associated with disruption in the fractallike long-range correlations that characterize healthy sinus rhythm cardiac interval dynamics. Ten young (21-34 yr) and 10 elderly (68-81 yr) rigorously screened healthy subjects underwent 120 min of continuous supine resting electrocardiographic recording. We analyzed the interbeat interval time series using standard time and frequency domain statistics and using a fractal measure, detrended fluctuation analysis, to quantify long-range correlation properties. In healthy young subjects, interbeat intervals demonstrated fractal scaling, with scaling exponents (alpha) from the fluctuation analysis close to a value of 1.0. In the group of healthy elderly subjects, the interbeat interval time series had two scaling regions. Over the short range, interbeat interval fluctuations resembled a random walk process (Brownian noise, alpha = 1.5), whereas over the longer range they resembled white noise (alpha = 0.5). Short (alpha s)- and long-range (alpha 1) scaling exponents were significantly different in the elderly subjects compared with young (alpha s = 1.12 +/- 0.19 vs. 0.90 +/- 0.14, respectively, P = 0.009; alpha 1 = 0.75 +/- 0.17 vs. 0.99 +/- 0.10, respectively, P = 0.002). The crossover behavior from one scaling region to another could be modeled as a first-order autoregressive process, which closely fit the data from four elderly subjects. This implies that a single characteristic time scale may be dominating heartbeat control in these subjects. The age-related loss of fractal organization in heartbeat dynamics may reflect the degradation of integrated physiological regulatory systems and may impair an individual's ability to adapt to stress.

  3. Comparison of different volumes of high intensity interval training on cardiac autonomic function in sedentary young women.

    PubMed

    Bhati, Pooja; Bansal, Vishal; Moiz, Jamal Ali

    2017-08-24

    Purpose The present study was conducted to compare the effects of low volume of high intensity interval training (LVHIIT) and high volume of high intensity interval training (HVHIIT) on heart rate variability (HRV) as a primary outcome measure, and on maximum oxygen consumption (VO2max), body composition, and lower limb muscle strength as secondary outcome measures, in sedentary young women. Methods Thirty-six participants were recruited in this study. The LVHIIT group (n = 17) performed one 4-min bout of treadmill running at 85%-95% maximum heart rate (HRmax), followed by 3 min of recovery by running at 70% HRmax, three times per week for 6 weeks. The HVHIIT group (n = 15) performed four times 4-min bouts of treadmill running at 85%-95% HRmax, interspersed with 3-min of recovery by running at 70% HRmax, 3 times per week for 6 weeks. All criterion measures were measured before and after training in both the groups. Results Due to attrition of four cases, data of 32 participants was used for analysis. A significant increase in high frequency (HF) power (p < 0.001) and decrease in the ratio of low frequency to high frequency power (LF/HF) ratio (p < 0.001) in HRV parameters, was observed post-HVHIIT, whereas, these variables did not change significantly (HF: p = 0.92, LF/HF ratio: p = 0.52) in LVHIIT group. Nevertheless, both the interventions proved equally effective in improving aerobic capacity (VO2max), body composition, and muscle strength. Conclusion The study results suggest that both LVHIIT and HVHIIT are equally effective in improving VO2max, body composition, and muscle strength, in sedentary young women. However, HVHIIT induces parasympathetic dominance as well, as measured by HRV.

  4. A general dead-time correction method based on live-time stamping. Application to the measurement of short-lived radionuclides.

    PubMed

    Chauvenet, B; Bobin, C; Bouchard, J

    2017-12-01

    Dead-time correction formulae are established in the general case of superimposed non-homogeneous Poisson processes. Based on the same principles as conventional live-timed counting, this method exploits the additional information made available using digital signal processing systems, and especially the possibility to store the time stamps of live-time intervals. No approximation needs to be made to obtain those formulae. Estimates of the variances of corrected rates are also presented. This method is applied to the activity measurement of short-lived radionuclides. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. How to Handle a Satellite Change in an Operational TWSTFT Network?

    DTIC Science & Technology

    2010-11-01

    42 nd Annual Precise Time and Time Interval (PTTI) Meeting 285 HOW TO HANDLE A SATELLITE CHANGE IN AN OPERATIONAL TWSTFT NETWORK...way satellite time and frequency transfer ( TWSTFT ) is a powerful technique because of its real-time capabilities. In principle, the time difference...between remote clocks is almost instantaneously known after a measurement session. Long-term TWSTFT operations have required changes between

  6. Advanced analysis of finger-tapping performance: a preliminary study.

    PubMed

    Barut, Cağatay; Kızıltan, Erhan; Gelir, Ethem; Köktürk, Fürüzan

    2013-06-01

    The finger-tapping test is a commonly employed quantitative assessment tool used to measure motor performance in the upper extremities. This task is a complex motion that is affected by external stimuli, mood and health status. The complexity of this task is difficult to explain with a single average intertap-interval value (time difference between successive tappings) which only provides general information and neglects the temporal effects of the aforementioned factors. This study evaluated the time course of average intertap-interval values and the patterns of variation in both the right and left hands of right-handed subjects using a computer-based finger-tapping system. Cross sectional study. Thirty eight male individuals aged between 20 and 28 years (Mean±SD = 22.24±1.65) participated in the study. Participants were asked to perform single-finger-tapping test for 10 seconds of test period. Only the results of right-handed (RH) 35 participants were considered in this study. The test records the time of tapping and saves data as the time difference between successive tappings for further analysis. The average number of tappings and the temporal fluctuation patterns of the intertap-intervals were calculated and compared. The variations in the intertap-interval were evaluated with the best curve fit method. An average tapping speed or tapping rate can reliably be defined for a single-finger tapping test by analysing the graphically presented data of the number of tappings within the test period. However, a different presentation of the same data, namely the intertap-interval values, shows temporal variation as the number of tapping increases. Curve fitting applications indicate that the variation has a biphasic nature. The measures obtained in this study reflect the complex nature of the finger-tapping task and are suggested to provide reliable information regarding hand performance. Moreover, the equation reflects both the variations in and the general patterns associated with the task.

  7. Measurement of the timing behaviour of off-the-shelf cameras

    NASA Astrophysics Data System (ADS)

    Schatz, Volker

    2017-04-01

    This paper presents a measurement method suitable for investigating the timing properties of cameras. A single light source illuminates the camera detector starting with a varying defined delay after the camera trigger. Pixels from the recorded camera frames are summed up and normalised, and the resulting function is indicative of the overlap between illumination and exposure. This allows one to infer the trigger delay and the exposure time with sub-microsecond accuracy. The method is therefore of interest when off-the-shelf cameras are used in reactive systems or synchronised with other cameras. It can supplement radiometric and geometric calibration methods for cameras in scientific use. A closer look at the measurement results reveals deviations from the ideal camera behaviour of constant sensitivity limited to the exposure interval. One of the industrial cameras investigated retains a small sensitivity long after the end of the nominal exposure interval. All three investigated cameras show non-linear variations of sensitivity at O≤ft({{10}-3}\\right) to O≤ft({{10}-2}\\right) during exposure. Due to its sign, the latter effect cannot be described by a sensitivity function depending on the time after triggering, but represents non-linear pixel characteristics.

  8. A comparative analysis of spectral exponent estimation techniques for 1/fβ processes with applications to the analysis of stride interval time series

    PubMed Central

    Schaefer, Alexander; Brach, Jennifer S.; Perera, Subashan; Sejdić, Ervin

    2013-01-01

    Background The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f) = 1/fβ. The scaling exponent β is thus often interpreted as a “biomarker” of relative health and decline. New Method This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. Results The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Comparison with Existing Methods: Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. Conclusions The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. PMID:24200509

  9. A comparative analysis of spectral exponent estimation techniques for 1/f(β) processes with applications to the analysis of stride interval time series.

    PubMed

    Schaefer, Alexander; Brach, Jennifer S; Perera, Subashan; Sejdić, Ervin

    2014-01-30

    The time evolution and complex interactions of many nonlinear systems, such as in the human body, result in fractal types of parameter outcomes that exhibit self similarity over long time scales by a power law in the frequency spectrum S(f)=1/f(β). The scaling exponent β is thus often interpreted as a "biomarker" of relative health and decline. This paper presents a thorough comparative numerical analysis of fractal characterization techniques with specific consideration given to experimentally measured gait stride interval time series. The ideal fractal signals generated in the numerical analysis are constrained under varying lengths and biases indicative of a range of physiologically conceivable fractal signals. This analysis is to complement previous investigations of fractal characteristics in healthy and pathological gait stride interval time series, with which this study is compared. The results of our analysis showed that the averaged wavelet coefficient method consistently yielded the most accurate results. Class dependent methods proved to be unsuitable for physiological time series. Detrended fluctuation analysis as most prevailing method in the literature exhibited large estimation variances. The comparative numerical analysis and experimental applications provide a thorough basis for determining an appropriate and robust method for measuring and comparing a physiologically meaningful biomarker, the spectral index β. In consideration of the constraints of application, we note the significant drawbacks of detrended fluctuation analysis and conclude that the averaged wavelet coefficient method can provide reasonable consistency and accuracy for characterizing these fractal time series. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    NASA Astrophysics Data System (ADS)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  11. The Time Course of the Probability of Transition Into and Out of REM Sleep

    PubMed Central

    Bassi, Alejandro; Vivaldi, Ennio A.; Ocampo-Garcés, Adrián

    2009-01-01

    Study Objectives: A model of rapid eye movement (REM) sleep expression is proposed that assumes underlying regulatory mechanisms operating as inhomogenous Poisson processes, the overt results of which are the transitions into and out of REM sleep. Design: Based on spontaneously occurring REM sleep episodes (“Episode”) and intervals without REM sleep (“Interval”), 3 variables are defined and evaluated over discrete 15-second epochs using a nonlinear logistic regression method: “Propensity” is the instantaneous rate of into-REM transition occurrence throughout an Interval, “Volatility” is the instantaneous rate of out-of-REM transition occurrence throughout an Episode, and “Opportunity” is the probability of being in non-REM (NREM) sleep at a given time throughout an Interval, a requisite for transition. Setting: 12:12 light:dark cycle, isolated boxes. Participants: Sixteen male Sprague-Dawley rats Interventions: None. Spontaneous sleep cycles. Measurements and Results: The highest levels of volatility and propensity occur, respectively, at the very beginning of Episodes and Intervals. The new condition stabilizes rapidly, and variables reach nadirs at minute 1.25 and 2.50, respectively. Afterward, volatility increases markedly, reaching values close to the initial level. Propensity increases moderately, the increment being stronger through NREM sleep bouts occurring at the end of long Intervals. Short-term homeostasis is evidenced by longer REM sleep episodes lowering propensity in the following Interval. Conclusions: The stabilization after transitions into Episodes or Intervals and the destabilization after remaining for some time in either condition may be described as resulting from continuous processes building up during Episodes and Intervals. These processes underlie the overt occurrence of transitions. Citation: Bassi A; Vivaldi EA; Ocampo-Garcées A. The time course of the probability of transition into and out of REM sleep. SLEEP 2009;32(5):655-669 PMID:19480233

  12. Steady, modest slip over multiple earthquake cycles on the Owens Valley and Little Lake fault zones

    NASA Astrophysics Data System (ADS)

    Amos, C. B.; Haddon, E. K.; Burgmann, R.; Zielke, O.; Jayko, A. S.

    2015-12-01

    A comprehensive picture of current plate-boundary deformation requires integration of short-term geodetic records with longer-term geologic strain. Comparing rates of deformation across these time intervals highlights potential time-dependencies in both geodetic and geologic records and yields critical insight into the earthquake deformation process. The southern Walker Lane Belt in eastern California represents one location where short-term strain recorded by geodesy apparently outpaces longer-term geologic fault slip measured from displaced rocks and landforms. This discrepancy persists both for individual structures and across the width of the deforming zone, where ~1 cm/yr of current dextral shear exceeds Quaternary slip rates summed across individual faults. The Owens Valley and Little Lake fault systems form the western boundary of the southern Walker Lane and host a range of published slip rate estimates from ~1 - 7 mm/yr over varying time intervals based on both geodetic and geologic measurements. New analysis of offset geomorphic piercing lines from airborne lidar and field measurements along the Owens Valley fault provides a snapshot of deformation during individual earthquakes and over many seismic cycles. Viewed in context of previously reported ages from pluvial and other landforms in Owens Valley, these offsets suggest slip rates of ~0.6 - 1.6 mm/yr over the past 103 - 105 years. Such rates agree with similar estimates immediately to the south on the Little Lake fault, where lidar measurements indicate dextral slip averaging ~0.6 - 1.3 mm/yr over comparable time intervals. Taken together, these results suggest steady, modest slip in the absence of significant variations over the Mid-to-Late Quaternary for a ~200 km span of the southwestern Walker Lane. Our findings argue against the presence of long-range fault interactions and slip-rate variations for this portion of the larger, regional fault network. This result also suggests that faster slip-rate estimates from geodetic measurements reflect transients over much shorter time scales. Additionally, the persistence of relatively faster geodetic shear in comparison with time-averaged fault slip leaves open the possibility of significant off-fault deformation or slip on subsidiary structures across the Owens Valley.

  13. 40 CFR 797.1300 - Daphnid acute toxicity test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...

  14. 40 CFR 797.1300 - Daphnid acute toxicity test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...

  15. 40 CFR 797.1300 - Daphnid acute toxicity test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...

  16. 40 CFR 797.1300 - Daphnid acute toxicity test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...

  17. 40 CFR 797.1300 - Daphnid acute toxicity test.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... continuous exposure over a specified period of time. In this guideline, the effect measured is immobilization... at a point in time, or passing through the test chamber during a specific interval. (7) Static system..., daphnids which have been cultured and acclimated in accordance with the test design are randomly placed...

  18. Measuring Skew in Average Surface Roughness as a Function of Surface Preparation

    NASA Technical Reports Server (NTRS)

    Stahl, Mark

    2015-01-01

    Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.

  19. Human sinus arrhythmia as an index of vagal cardiac outflow

    NASA Technical Reports Server (NTRS)

    Eckberg, D. L.

    1983-01-01

    The human central vagal mechanisms were investigated by measuring the intervals between heartbeats during controlled breathing (at breathing intervals of 2.5-10 s and nominal tidal volumes of 1000 and 1500 ml) in six young men and women. It was found that as the breathing interval increased, the longest heart periods became longer, the shortest heart periods became shorter, and the peak-valley P-P intervals increased asymptotically. Peak-valley intervals also increased in proportion to tidal volume, although this influence was small. The phase angles between heart period changes and respiration were found to vary as linear functions of breathing interval. Heart period shortening began in inspiration at short breathing intervals and in expiration at long breathing intervals, while heart period lengthening began in early expiration at all breathing intervals studied. It is concluded that a close relationship exists between variations of respiratory depth and interval and the quantity, periodicity, and timing of vagal cardiac outflow in conscious humans. The results indicate that at usual breathing rates, phasic respiration-related changes of vagal motoneuron activity begin in expiration, progress slowly, and are incompletely expressed at fast breathing ratges.

  20. Shear Bond Strengths of Different Adhesive Systems to Biodentine

    PubMed Central

    Odabaş, Mesut Enes; Bani, Mehmet; Tirali, Resmiye Ebru

    2013-01-01

    The aim of this study was to measure the shear bond strength of different adhesive systems to Biodentine with different time intervals. Eighty specimens of Biodentine were prepared and divided into 8 groups. After 12 minutes, 40 samples were randomly selected and divided into 4 groups of 10 each: group 1: (etch-and-rinse adhesive system) Prime & Bond NT; group 2: (2-step self-etch adhesive system) Clearfil SE Bond; group 3: (1-step self-etch adhesive systems) Clearfil S3 Bond; group 4: control (no adhesive). After the application of adhesive systems, composite resin was applied over Biodentine. This procedure was repeated 24 hours after mixing additional 40 samples, respectively. Shear bond strengths were measured using a universal testing machine, and the data were subjected to 1-way analysis of variance and Scheffé post hoc test. No significant differences were found between all of the adhesive groups at the same time intervals (12 minutes and 24 hours) (P > .05). Among the two time intervals, the lowest value was obtained for group 1 (etch-and-rinse adhesive) at a 12-minute period, and the highest was obtained for group 2 (two-step self-etch adhesive) at a 24-hour period. The placement of composite resin used with self-etch adhesive systems over Biodentine showed better shear bond strength. PMID:24222742

  1. Shear bond strengths of different adhesive systems to biodentine.

    PubMed

    Odabaş, Mesut Enes; Bani, Mehmet; Tirali, Resmiye Ebru

    2013-01-01

    The aim of this study was to measure the shear bond strength of different adhesive systems to Biodentine with different time intervals. Eighty specimens of Biodentine were prepared and divided into 8 groups. After 12 minutes, 40 samples were randomly selected and divided into 4 groups of 10 each: group 1: (etch-and-rinse adhesive system) Prime & Bond NT; group 2: (2-step self-etch adhesive system) Clearfil SE Bond; group 3: (1-step self-etch adhesive systems) Clearfil S(3) Bond; group 4: control (no adhesive). After the application of adhesive systems, composite resin was applied over Biodentine. This procedure was repeated 24 hours after mixing additional 40 samples, respectively. Shear bond strengths were measured using a universal testing machine, and the data were subjected to 1-way analysis of variance and Scheffé post hoc test. No significant differences were found between all of the adhesive groups at the same time intervals (12 minutes and 24 hours) (P > .05). Among the two time intervals, the lowest value was obtained for group 1 (etch-and-rinse adhesive) at a 12-minute period, and the highest was obtained for group 2 (two-step self-etch adhesive) at a 24-hour period. The placement of composite resin used with self-etch adhesive systems over Biodentine showed better shear bond strength.

  2. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    PubMed

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. The impact of children's internalizing and externalizing problems on parenting: Transactional processes and reciprocal change over time.

    PubMed

    Serbin, Lisa A; Kingdon, Danielle; Ruttle, Paula L; Stack, Dale M

    2015-11-01

    Most theoretical models of developmental psychopathology involve a transactional, bidirectional relation between parenting and children's behavior problems. The present study utilized a cross-lagged panel, multiple interval design to model change in bidirectional relations between child and parent behavior across successive developmental periods. Two major categories of child behavior problems, internalizing and externalizing, and two aspects of parenting, positive (use of support and structure) and harsh discipline (use of physical punishment), were modeled across three time points spaced 3 years apart. Two successive developmental intervals, from approximately age 7.5 to 10.5 and from 10.5 to 13.5, were included. Mother-child dyads (N = 138; 65 boys) from a lower income longitudinal sample of families participated, with standardized measures of mothers rating their own parenting behavior and teachers reporting on child's behavior. Results revealed different types of reciprocal relations between specific aspects of child and parent behavior, with internalizing problems predicting an increase in positive parenting over time, which subsequently led to a reduction in internalizing problems across the successive 3-year interval. In contrast, externalizing predicted reduced levels of positive parenting in a reciprocal sequence that extended across two successive intervals and predicted increased levels of externalizing over time. Implications for prevention and early intervention are discussed.

  4. Modeling the heterogeneity of human dynamics based on the measurements of influential users in Sina Microblog

    NASA Astrophysics Data System (ADS)

    Wang, Chenxu; Guan, Xiaohong; Qin, Tao; Yang, Tao

    2015-06-01

    Online social network has become an indispensable communication tool in the information age. The development of microblog also provides us a great opportunity to study human dynamics that play a crucial role in the design of efficient communication systems. In this paper we study the characteristics of the tweeting behavior based on the data collected from Sina Microblog. The user activity level is measured to characterize how often a user posts a tweet. We find that the user activity level follows a bimodal distribution. That is, the microblog users tend to be either active or inactive. The inter-tweeting time distribution is then measured at both the aggregate and individual levels. We find that the inter-tweeting time follows a piecewise power law distribution of two tails. Furthermore, the exponents of the two tails have different correlations with the user activity level. These findings demonstrate that the dynamics of the tweeting behavior are heterogeneous in different time scales. We then develop a dynamic model co-driven by the memory and the interest mechanism to characterize the heterogeneity. The numerical simulations validate the model and verify that the short time interval tweeting behavior is driven by the memory mechanism while the long time interval behavior by the interest mechanism.

  5. A 4.2 ps Time-Interval RMS Resolution Time-to-Digital Converter Using a Bin Decimation Method in an UltraScale FPGA

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Liu, Chong

    2016-10-01

    The common solution for a field programmable gate array (FPGA)-based time-to-digital converter (TDC) is constructing a tapped delay line (TDL) for time interpolation to yield a sub-clock time resolution. The granularity and uniformity of the delay elements of TDL determine the TDC time resolution. In this paper, we propose a dual-sampling TDL architecture and a bin decimation method that could make the delay elements as small and uniform as possible, so that the implemented TDCs can achieve a high time resolution beyond the intrinsic cell delay. Two identical full hardware-based TDCs were implemented in a Xilinx UltraScale FPGA for performance evaluation. For fixed time intervals in the range from 0 to 440 ns, the average time-interval RMS resolution is measured by the two TDCs with 4.2 ps, thus the timestamp resolution of single TDC is derived as 2.97 ps. The maximum hit rate of the TDC is as high as half the system clock rate of FPGA, namely 250 MHz in our demo prototype. Because the conventional online bin-by-bin calibration is not needed, the implementation of the proposed TDC is straightforward and relatively resource-saving.

  6. Altered fractal dynamics of gait: reduced stride-interval correlations with aging and Huntington's disease

    NASA Technical Reports Server (NTRS)

    Hausdorff, J. M.; Mitchell, S. L.; Firtion, R.; Peng, C. K.; Cudkowicz, M. E.; Wei, J. Y.; Goldberger, A. L.

    1997-01-01

    Fluctuations in the duration of the gait cycle (the stride interval) display fractal dynamics and long-range correlations in healthy young adults. We hypothesized that these stride-interval correlations would be altered by changes in neurological function associated with aging and certain disease states. To test this hypothesis, we compared the stride-interval time series of 1) healthy elderly subjects and young controls and of 2) subjects with Huntington's disease and healthy controls. Using detrended fluctuation analysis we computed alpha, a measure of the degree to which one stride interval is correlated with previous and subsequent intervals over different time scales. The scaling exponent alpha was significantly lower in elderly subjects compared with young subjects (elderly: 0.68 +/- 0.14; young: 0.87 +/- 0.15; P < 0.003). The scaling exponent alpha was also smaller in the subjects with Huntington's disease compared with disease-free controls (Huntington's disease: 0.60 +/- 0.24; controls: 0.88 +/-0.17; P < 0.005). Moreover, alpha was linearly related to degree of functional impairment in subjects with Huntington's disease (r = 0.78, P < 0.0005). These findings demonstrate that strike-interval fluctuations are more random (i.e., less correlated) in elderly subjects and in subjects with Huntington's disease. Abnormal alterations in the fractal properties of gait dynamics are apparently associated with changes in central nervous system control.

  7. Averaging interval selection for the calculation of Reynolds shear stress for studies of boundary layer turbulence.

    NASA Astrophysics Data System (ADS)

    Lee, Zoe; Baas, Andreas

    2013-04-01

    It is widely recognised that boundary layer turbulence plays an important role in sediment transport dynamics in aeolian environments. Improvements in the design and affordability of ultrasonic anemometers have provided significant contributions to studies of aeolian turbulence, by facilitating high frequency monitoring of three dimensional wind velocities. Consequently, research has moved beyond studies of mean airflow properties, to investigations into quasi-instantaneous turbulent fluctuations at high spatio-temporal scales. To fully understand, how temporal fluctuations in shear stress drive wind erosivity and sediment transport, research into the best practice for calculating shear stress is necessary. This paper builds upon work published by Lee and Baas (2012) on the influence of streamline correction techniques on Reynolds shear stress, by investigating the time-averaging interval used in the calculation. Concerns relating to the selection of appropriate averaging intervals for turbulence research, where the data are typically non-stationary at all timescales, are well documented in the literature (e.g. Treviño and Andreas, 2000). For example, Finnigan et al. (2003) found that underestimating the required averaging interval can lead to a reduction in the calculated momentum flux, as contributions from turbulent eddies longer than the averaging interval are lost. To avoid the risk of underestimating fluxes, researchers have typically used the total measurement duration as a single averaging period. For non-stationary data, however, using the whole measurement run as a single block average is inadequate for defining turbulent fluctuations. The data presented in this paper were collected in a field study of boundary layer turbulence conducted at Tramore beach near Rosapenna, County Donegal, Ireland. High-frequency (50 Hz) 3D wind velocity measurements were collected using ultrasonic anemometry at thirteen different heights between 0.11 and 1.62 metres above the bed. A technique for determining time-averaging intervals for a series of anemometers stacked in a close vertical array is presented. A minimum timescale is identified using spectral analysis to determine the inertial sub-range, where energy is neither produced nor dissipated but passed down to increasingly smaller scales. An autocorrelation function is then used to derive a scaling pattern between anemometer heights, which defines a series of averaging intervals of increasing length with height above the surface. Results demonstrate the effect of different averaging intervals on the calculation of Reynolds shear stress and highlight the inadequacy of using the total measurement duration as a single block average. Lee, Z. S. & Baas, A. C. W. (2012). Streamline correction for the analysis of boundary layer turbulence. Geomorphology, 171-172, 69-82. Treviño, G. and Andreas, E.L., 2000. Averaging Intervals For Spectral Analysis Of Nonstationary Turbulence. Boundary-Layer Meteorology, 95(2): 231-247. Finnigan, J.J., Clement, R., Malhi, Y., Leuning, R. and Cleugh, H.A., 2003. Re-evaluation of long-term flux measurement techniques. Part I: Averaging and coordinate rotation. Boundary-Layer Meteorology, 107(1): 1-48.

  8. Influence of the Time Scale on the Construction of Financial Networks

    PubMed Central

    Emmert-Streib, Frank; Dehmer, Matthias

    2010-01-01

    Background In this paper we investigate the definition and formation of financial networks. Specifically, we study the influence of the time scale on their construction. Methodology/Principal Findings For our analysis we use correlation-based networks obtained from the daily closing prices of stock market data. More precisely, we use the stocks that currently comprise the Dow Jones Industrial Average (DJIA) and estimate financial networks where nodes correspond to stocks and edges correspond to none vanishing correlation coefficients. That means only if a correlation coefficient is statistically significant different from zero, we include an edge in the network. This construction procedure results in unweighted, undirected networks. By separating the time series of stock prices in non-overlapping intervals, we obtain one network per interval. The length of these intervals corresponds to the time scale of the data, whose influence on the construction of the networks will be studied in this paper. Conclusions/Significance Numerical analysis of four different measures in dependence on the time scale for the construction of networks allows us to gain insights about the intrinsic time scale of the stock market with respect to a meaningful graph-theoretical analysis. PMID:20949124

  9. Talofibular interval changes after acute ankle sprain: a stress ultrasonography study of ankle laxity.

    PubMed

    Croy, Theodore; Saliba, Susan; Saliba, Ethan; Anderson, Mark W; Hertel, Jay

    2013-11-01

    Quantifying talocrural joint laxity after ankle sprain is problematic. Stress ultrasonography (US) can image the lateral talocrural joint and allow the measurement of the talofibular interval, which may suggest injury to the anterior talofibular ligament (ATFL). The acute talofibular interval changes after lateral ankle sprain are unknown. Twenty-five participants (9 male, 16 female; age 21.8 ± 3.2 y, height 167.8 ± 34.1 cm, mass 72.7 ± 13.8 kg) with 27 acute, lateral ankle injuries underwent bilateral stress US imaging at baseline (<7 d) and on the affected ankle at 3 wk and 6 wk from injury in 3 ankle conditions: neutral, anterior drawer, and inversion. Talofibular interval (mm) was measured using imaging software and self-reported function (activities of daily living [ADL] and sports) by the Foot and Ankle Ability Measure (FAAM). The talofibular interval increased with anterior-drawer stress in the involved ankle (22.65 ± 3.75 mm; P = .017) over the uninvolved ankle (19.45 ± 2.35 mm; limb × position F1,26 = 4.9, P = .035) at baseline. Inversion stress also resulted in greater interval changes (23.41 ± 2.81 mm) than in the uninvolved ankles (21.13 ± 2.08 mm). A main effect for time was observed for inversion (F2,52 = 4.3, P = .019, 21.93 ± 2.24 mm) but not for anterior drawer (F2,52 = 3.1, P = .055, 21.18 ± 2.34 mm). A significant reduction in the talofibular interval took place between baseline and week 3 inversion measurements only (F1,26 = 5.6, P = .026). FAAM-ADL and sports results increased significantly from baseline to wk 3 (21.9 ± 16.2, P < .0001 and 23.8 ± 16.9, P < .0001) and from wk 3 to wk 6 (2.5 ± 4.4, P = .009 and 10.5 ± 13.2, P = .001). Stress US methods identified increased talofibular interval changes suggestive of talocrural laxity and ATFL injury using anterior drawer and inversion stress that, despite significant improvements in self-reported function, only marginally improved during the 6 wk after ankle sprain. Stress US provides a safe, repeatable, and quantifiable method of measuring the talofibular interval and may augment manual stress examinations in acute ankle injuries.

  10. Research on the Forward and Reverse Calculation Based on the Adaptive Zero-Velocity Interval Adjustment for the Foot-Mounted Inertial Pedestrian-Positioning System

    PubMed Central

    Wang, Qiuying; Guo, Zheng; Sun, Zhiguo; Cui, Xufei; Liu, Kaiyue

    2018-01-01

    Pedestrian-positioning technology based on the foot-mounted micro inertial measurement unit (MIMU) plays an important role in the field of indoor navigation and has received extensive attention in recent years. However, the positioning accuracy of the inertial-based pedestrian-positioning method is rapidly reduced because of the relatively low measurement accuracy of the measurement sensor. The zero-velocity update (ZUPT) is an error correction method which was proposed to solve the cumulative error because, on a regular basis, the foot is stationary during the ordinary gait; this is intended to reduce the position error growth of the system. However, the traditional ZUPT has poor performance because the time of foot touchdown is short when the pedestrians move faster, which decreases the positioning accuracy. Considering these problems, a forward and reverse calculation method based on the adaptive zero-velocity interval adjustment for the foot-mounted MIMU location method is proposed in this paper. To solve the inaccuracy of the zero-velocity interval detector during fast pedestrian movement where the contact time of the foot on the ground is short, an adaptive zero-velocity interval detection algorithm based on fuzzy logic reasoning is presented in this paper. In addition, to improve the effectiveness of the ZUPT algorithm, forward and reverse multiple solutions are presented. Finally, with the basic principles and derivation process of this method, the MTi-G710 produced by the XSENS company is used to complete the test. The experimental results verify the correctness and applicability of the proposed method. PMID:29883399

  11. Components of the Motor Program: The Cerebellum as an Internal Clock. Cognitive Science Program, Technical Report No 86-7.

    ERIC Educational Resources Information Center

    Ivry, Richard B.; Keele, Steven W.

    This report summarizes the initial phase of research with neurological patients on timing functions. Parkinsonian, cerebellar, cortical and peripheral neuropathy patients as well as college aged and elderly control subjects were tested on two separate measures of timing functions. The first task involved the production of timed intervals and used…

  12. Flow Control and Measurement in Electric Propulsion Systems: Towards an AIAA Reference Standard

    DTIC Science & Technology

    2013-10-01

    the spacecraft sensors, although some improvement can be made by averaging several measurements together. 3. Thermal Mass Gauging Thermal Mass...flow controllers (MFCs) to measure and control propellant into EP devices. To determine several key thruster performance parameters with a low level...the specified time interval may not be known. A first recourse is to perform several measurements and examine the linearity. In cases where the

  13. Celestial-mechanical interpretation of the two-way radio measurements of radial velocity of spacecraft for scientific applications

    NASA Astrophysics Data System (ADS)

    Komovkin, S. V.; Lavrenov, S. M.; Tuchin, A. G.; Tuchin, D. A.; Yaroshevsky, V. S.

    2016-12-01

    The article describes a model of the two-way measurements of radial velocity based on the Doppler effect. The relations are presented for the instantaneous value of the increment range at the time of measurement and the radial velocity of the mid-dimensional interval. The compensation of methodological errors of interpretation of the two-way Doppler measurements is considered.

  14. Methods of measurement signal acquisition from the rotational flow meter for frequency analysis

    NASA Astrophysics Data System (ADS)

    Świsulski, Dariusz; Hanus, Robert; Zych, Marcin; Petryka, Leszek

    One of the simplest and commonly used instruments for measuring the flow of homogeneous substances is the rotational flow meter. The main part of such a device is a rotor (vane or screw) rotating at a speed which is the function of the fluid or gas flow rate. A pulse signal with a frequency proportional to the speed of the rotor is obtained at the sensor output. For measurements in dynamic conditions, a variable interval between pulses prohibits the analysis of the measuring signal. Therefore, the authors of the article developed a method involving the determination of measured values on the basis of the last inter-pulse interval preceding the moment designated by the timing generator. For larger changes of the measured value at a predetermined time, the value can be determined by means of extrapolation of the two adjacent interpulse ranges, assuming a linear change in the flow. The proposed methods allow analysis which requires constant spacing between measurements, allowing for an analysis of the dynamics of changes in the test flow, eg. using a Fourier transform. To present the advantages of these methods simulations of flow measurement were carried out with a DRH-1140 rotor flow meter from the company Kobold.

  15. Effects of 4-aminopyridine on cardiac repolarization, PR interval, and heart rate in patients with spinal cord injury.

    PubMed

    Isoda, Wakana C; Segal, Jack L

    2003-02-01

    To determine the effects of 4-aminopyridine (4-AP) on heart rate and PR, QT, and QTc intervals in patients with longstanding spinal cord injury (SCI). Randomized, active-treatment-controlled, dose level-blinded study, with allocation concealed. University-affiliated, tertiary care medical center. Sixty otherwise healthy male and female outpatients with traumatic SCI of more than 1 year's duration. Intervention. Oral administration and dose titration to tolerance of an immediate-release formulation of 4-AP. The PR interval, heart rate, QT interval, and QTc interval obtained from standard 12-lead electrocardiograms (ECGs) at baseline (before administration of 4-AP) and after 1 month of treatment were compared. The QTc intervals were derived by using Bazett's formula (equation) incorporated into standard computerized analyses of 12-lead ECG printouts. The paired t test was performed to test for the significance of differences between means and variances. No statistically significant differences were noted in heart rate or between ECG time intervals measured at baseline and after 1 month of treatment with 4-AP among all patients with SCI or between subgroups stratified by injury level (tetraplegia, paraplegia) or sex. During the 1-month period that 4-AP was administered, the heart rate and PR, QT, and QTc intervals all remained unchanged and stayed well within normal range in comparison to literature-derived control values. 4-Aminopyridine does not appear to influence the length of cardiac time intervals or heart rate and, hence, is unlikely to cause potentially life-threatening ventricular dysrrhythmias when administered long-term and taken orally in dosages of up to 30 mg/day. Specifically, cardiac repolarization (QTc interval) is unaffected in patients with SCI who continuously receive 4-AP for up to 1 month.

  16. How to Calculate Renyi Entropy from Heart Rate Variability, and Why it Matters for Detecting Cardiac Autonomic Neuropathy.

    PubMed

    Cornforth, David J; Tarvainen, Mika P; Jelinek, Herbert F

    2014-01-01

    Cardiac autonomic neuropathy (CAN) is a disease that involves nerve damage leading to an abnormal control of heart rate. An open question is to what extent this condition is detectable from heart rate variability (HRV), which provides information only on successive intervals between heart beats, yet is non-invasive and easy to obtain from a three-lead ECG recording. A variety of measures may be extracted from HRV, including time domain, frequency domain, and more complex non-linear measures. Among the latter, Renyi entropy has been proposed as a suitable measure that can be used to discriminate CAN from controls. However, all entropy methods require estimation of probabilities, and there are a number of ways in which this estimation can be made. In this work, we calculate Renyi entropy using several variations of the histogram method and a density method based on sequences of RR intervals. In all, we calculate Renyi entropy using nine methods and compare their effectiveness in separating the different classes of participants. We found that the histogram method using single RR intervals yields an entropy measure that is either incapable of discriminating CAN from controls, or that it provides little information that could not be gained from the SD of the RR intervals. In contrast, probabilities calculated using a density method based on sequences of RR intervals yield an entropy measure that provides good separation between groups of participants and provides information not available from the SD. The main contribution of this work is that different approaches to calculating probability may affect the success of detecting disease. Our results bring new clarity to the methods used to calculate the Renyi entropy in general, and in particular, to the successful detection of CAN.

  17. How to Calculate Renyi Entropy from Heart Rate Variability, and Why it Matters for Detecting Cardiac Autonomic Neuropathy

    PubMed Central

    Cornforth, David J.;  Tarvainen, Mika P.; Jelinek, Herbert F.

    2014-01-01

    Cardiac autonomic neuropathy (CAN) is a disease that involves nerve damage leading to an abnormal control of heart rate. An open question is to what extent this condition is detectable from heart rate variability (HRV), which provides information only on successive intervals between heart beats, yet is non-invasive and easy to obtain from a three-lead ECG recording. A variety of measures may be extracted from HRV, including time domain, frequency domain, and more complex non-linear measures. Among the latter, Renyi entropy has been proposed as a suitable measure that can be used to discriminate CAN from controls. However, all entropy methods require estimation of probabilities, and there are a number of ways in which this estimation can be made. In this work, we calculate Renyi entropy using several variations of the histogram method and a density method based on sequences of RR intervals. In all, we calculate Renyi entropy using nine methods and compare their effectiveness in separating the different classes of participants. We found that the histogram method using single RR intervals yields an entropy measure that is either incapable of discriminating CAN from controls, or that it provides little information that could not be gained from the SD of the RR intervals. In contrast, probabilities calculated using a density method based on sequences of RR intervals yield an entropy measure that provides good separation between groups of participants and provides information not available from the SD. The main contribution of this work is that different approaches to calculating probability may affect the success of detecting disease. Our results bring new clarity to the methods used to calculate the Renyi entropy in general, and in particular, to the successful detection of CAN. PMID:25250311

  18. [Effects of a high intensity interval training on the aerobic capacity of adolescents].

    PubMed

    Huerta Ojeda, Álvaro; Galdames Maliqueo, Sergio; Cataldo Guerra, Marianela; Barahona Fuentes, Guillermo; Rozas Villanueva, Tania; Cáceres Serrano, Pablo

    2017-08-01

    If aerobic capacity is stimulated early in life, maximal oxygen consumption during adulthood is assured. To analyze the effects of a high intensity interval training (HIIT) in adolescents on the maximal oxygen consumption (VO2max) measured using the 20-m shuttle run test (20mSRT). Twenty eight teenagers aged 13 ± 0.6 years were divided in two groups of 14 subjects each. One group was to a 16 sessions of HIIT interval training based on their individual maximal aerobic speed and the other continued with their usual exercise done at school. At baseline and the end of the intervention VO2max was measured using the 20mSTR. At the end of the intervention, the trained teenagers significantly improved their VO2max and the time spent in the 20mSTR. A HIIT program based on the individual maximal aerobic speed improves VO2max in adolescents.

  19. Concentrations and allelopathic effects of benzoxazinoid compounds in soil treated with rye (Secale cereale) cover crop

    USDA-ARS?s Scientific Manuscript database

    Benzoxazinoids (Bx), a commonly investigated allelopathic chemical group, was measured in rye cover crop at the time of application and in soils at time-spaced intervals after treatment. The rye cover crop was applied under field conditions and at recommended doses as surface and incorporated trea...

  20. Improvements in Interval Time Tracking and Effects on Reading Achievement

    ERIC Educational Resources Information Center

    Taub, Gordon E.; McGrew, Kevin S.; Keith, Timothy Z.

    2007-01-01

    This study examined the effect of improvements in timing/rhythmicity on students' reading achievement. 86 participants completed pre- and post-test measures of reading achievement (i.e., Woodcock-Johnson III, Comprehensive Test of Phonological Processing, Test of Word Reading Efficiency, and Test of Silent Word Reading Fluency). Students in the…

  1. Interval Timing Is Preserved Despite Circadian Desynchrony in Rats: Constant Light and Heavy Water Studies.

    PubMed

    Petersen, Christian C; Mistlberger, Ralph E

    2017-08-01

    The mechanisms that enable mammals to time events that recur at 24-h intervals (circadian timing) and at arbitrary intervals in the seconds-to-minutes range (interval timing) are thought to be distinct at the computational and neurobiological levels. Recent evidence that disruption of circadian rhythmicity by constant light (LL) abolishes interval timing in mice challenges this assumption and suggests a critical role for circadian clocks in short interval timing. We sought to confirm and extend this finding by examining interval timing in rats in which circadian rhythmicity was disrupted by long-term exposure to LL or by chronic intake of 25% D 2 O. Adult, male Sprague-Dawley rats were housed in a light-dark (LD) cycle or in LL until free-running circadian rhythmicity was markedly disrupted or abolished. The rats were then trained and tested on 15- and 30-sec peak-interval procedures, with water restriction used to motivate task performance. Interval timing was found to be unimpaired in LL rats, but a weak circadian activity rhythm was apparently rescued by the training procedure, possibly due to binge feeding that occurred during the 15-min water access period that followed training each day. A second group of rats in LL were therefore restricted to 6 daily meals scheduled at 4-h intervals. Despite a complete absence of circadian rhythmicity in this group, interval timing was again unaffected. To eliminate all possible temporal cues, we tested a third group of rats in LL by using a pseudo-randomized schedule. Again, interval timing remained accurate. Finally, rats tested in LD received 25% D 2 O in place of drinking water. This markedly lengthened the circadian period and caused a failure of LD entrainment but did not disrupt interval timing. These results indicate that interval timing in rats is resistant to disruption by manipulations of circadian timekeeping previously shown to impair interval timing in mice.

  2. Cardiac conductive disturbance in patients with polycystic ovary syndrome.

    PubMed

    Huang, Jen-Hung; Tsai, Jen-Chen; Hsu, Ming-I; Chen, Yi-Jen

    2010-12-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine abnormality of reproductive-aged women and increases the risk of cardiovascular disease. However, the effects of PCOS on electrocardiograms (ECGs) are not fully elucidated. The aim of this study was to evaluate the characteristics of ECGs in patients with PCOS. This study included 24 patients with PCOS and 12 patients without PCOS. The heart rate, PR interval, QRS duration, Sokolow-Lyon voltage (SV1 + RV5/6), Cornell voltage (RaVL + SV3), QT interval and QTc interval were measured in 12-lead ECGs. The QRS duration was wider in patients with PCOS than those without PCOS (91 ± 8 vs. 81 ± 10 ms, p < 0.05). The heart rate, PR interval, Sokolow-Lyon voltage, product of the QRS duration times Cornell voltage combination, QT interval, QTc interval, QT dispersion and QTc dispersion were similar between the two groups. PCOS is associated with a widening QRS duration, which may contribute to its increased cardiovascular risks.

  3. Modes of uncontrolled rotational motion of the Progress M-29M spacecraft

    NASA Astrophysics Data System (ADS)

    Belyaev, M. Yu.; Matveeva, T. V.; Monakhov, M. I.; Rulev, D. N.; Sazonov, V. V.

    2018-01-01

    We have reconstructed the uncontrolled rotational motion of the Progress M-29M transport cargo spacecraft in the single-axis solar orientation mode (the so-called sunward spin) and in the mode of the gravitational orientation of a rotating satellite. The modes were implemented on April 3-7, 2016 as a part of preparation for experiments with the DAKON convection sensor onboard the Progress spacecraft. The reconstruction was performed by integral statistical techniques using the measurements of the spacecraft's angular velocity and electric current from its solar arrays. The measurement data obtained in a certain time interval have been jointly processed using the least-squares method by integrating the equations of the spacecraft's motion relative to the center of mass. As a result of processing, the initial conditions of motion and parameters of the mathematical model have been estimated. The motion in the sunward spin mode is the rotation of the spacecraft with an angular velocity of 2.2 deg/s about the normal to the plane of solar arrays; the normal is oriented toward the Sun or forms a small angle with this direction. The duration of the mode is several orbit passes. The reconstruction has been performed over time intervals of up to 1 h. As a result, the actual rotational motion of the spacecraft relative to the Earth-Sun direction was obtained. In the gravitational orientation mode, the spacecraft was rotated about its longitudinal axis with an angular velocity of 0.1-0.2 deg/s; the longitudinal axis executed small oscillated relative to the local vertical. The reconstruction of motion relative to the orbital coordinate system was performed in time intervals of up to 7 h using only the angularvelocity measurements. The measurements of the electric current from solar arrays were used for verification.

  4. Explosive Strength of the Knee Extensors: The Influence of Criterion Trial Detection Methodology on Measurement Reproducibility

    PubMed Central

    Wiesinger, Hans-Peter; Wiemer, Nicolas; Kösters, Alexander; Müller, Erich

    2016-01-01

    Abstract The present study was conducted to assess test-retest reproducibility of explosive strength measurements during single-joint isometric knee extension using the IsoMed 2000 dynamometer. Thirty-one physically active male subjects (mean age: 23.7 years) were measured on two occasions separated by 48–72 h. The intraclass correlation coefficient (ICC 2,1) and the coefficient of variation (CV) were calculated for (i) maximum torque (MVC), (ii) the peak rate of torque development (RTDpeak) as well as for (iii) the average rate of torque development (RTD) and the impulse taken at several predefined time intervals (0–30 to 0–300 ms); thereby explosive strength variables were derived in two conceptually different versions: on the one hand from the MVC-trial (version I), on the other hand from the trial showing the RTDpeak (version II). High ICC-values (0.80–0.99) and acceptable CV-values (1.9–8.7%) could be found for MVC as well as for the RTD and the impulse taken at time intervals of ≥100 ms, regardless of whether version I or II was used. In contrast, measurements of the RTDpeak as well as the RTD and the impulse taken during the very early contraction phase (i.e. RTD/impulse0–30ms and RTD/impulse0–50ms) showed clearly weaker reproducibility results (ICC: 0.53–0.84; CV: 7.3–16.4%) and gave rise to considerable doubts as to clinical usefulness, especially when derived using version I. However, if there is a need to measure explosive strength for earlier time intervals in practice, it is, in view of stronger reproducibility results, recommended to concentrate on measures derived from version II, which is based on the RTDpeak-trial. PMID:28149337

  5. A Variable Oscillator Underlies the Measurement of Time Intervals in the Rostral Medial Prefrontal Cortex during Classical Eyeblink Conditioning in Rabbits.

    PubMed

    Caro-Martín, C Rocío; Leal-Campanario, Rocío; Sánchez-Campusano, Raudel; Delgado-García, José M; Gruart, Agnès

    2015-11-04

    We were interested in determining whether rostral medial prefrontal cortex (rmPFC) neurons participate in the measurement of conditioned stimulus-unconditioned stimulus (CS-US) time intervals during classical eyeblink conditioning. Rabbits were conditioned with a delay paradigm consisting of a tone as CS. The CS started 50, 250, 500, 1000, or 2000 ms before and coterminated with an air puff (100 ms) directed at the cornea as the US. Eyelid movements were recorded with the magnetic search coil technique and the EMG activity of the orbicularis oculi muscle. Firing activities of rmPFC neurons were recorded across conditioning sessions. Reflex and conditioned eyelid responses presented a dominant oscillatory frequency of ≈12 Hz. The firing rate of each recorded neuron presented a single peak of activity with a frequency dependent on the CS-US interval (i.e., ≈12 Hz for 250 ms, ≈6 Hz for 500 ms, and≈3 Hz for 1000 ms). Interestingly, rmPFC neurons presented their dominant firing peaks at three precise times evenly distributed with respect to CS start and also depending on the duration of the CS-US interval (only for intervals of 250, 500, and 1000 ms). No significant neural responses were recorded at very short (50 ms) or long (2000 ms) CS-US intervals. rmPFC neurons seem not to encode the oscillatory properties characterizing conditioned eyelid responses in rabbits, but are probably involved in the determination of CS-US intervals of an intermediate range (250-1000 ms). We propose that a variable oscillator underlies the generation of working memories in rabbits. The way in which brains generate working memories (those used for the transient processing and storage of newly acquired information) is still an intriguing question. Here, we report that the firing activities of neurons located in the rostromedial prefrontal cortex recorded in alert behaving rabbits are controlled by a dynamic oscillator. This oscillator generated firing frequencies in a variable band of 3-12 Hz depending on the conditioned stimulus-unconditioned stimulus intervals (1 s, 500 ms, 250 ms) selected for classical eyeblink conditioning of behaving rabbits. Shorter (50 ms) and longer (2 s) intervals failed to activate the oscillator and prevented the acquisition of conditioned eyelid responses. This is an unexpected mechanism to generate sustained firing activities in neural circuits generating working memories. Copyright © 2015 the authors 0270-6474/15/3514809-13$15.00/0.

  6. A simulation model for determining the optimal size of emergency teams on call in the operating room at night.

    PubMed

    van Oostrum, Jeroen M; Van Houdenhoven, Mark; Vrielink, Manon M J; Klein, Jan; Hans, Erwin W; Klimek, Markus; Wullink, Gerhard; Steyerberg, Ewout W; Kazemier, Geert

    2008-11-01

    Hospitals that perform emergency surgery during the night (e.g., from 11:00 pm to 7:30 am) face decisions on optimal operating room (OR) staffing. Emergency patients need to be operated on within a predefined safety window to decrease morbidity and improve their chances of full recovery. We developed a process to determine the optimal OR team composition during the night, such that staffing costs are minimized, while providing adequate resources to start surgery within the safety interval. A discrete event simulation in combination with modeling of safety intervals was applied. Emergency surgery was allowed to be postponed safely. The model was tested using data from the main OR of Erasmus University Medical Center (Erasmus MC). Two outcome measures were calculated: violation of safety intervals and frequency with which OR and anesthesia nurses were called in from home. We used the following input data from Erasmus MC to estimate distributions of all relevant parameters in our model: arrival times of emergency patients, durations of surgical cases, length of stay in the postanesthesia care unit, and transportation times. In addition, surgeons and OR staff of Erasmus MC specified safety intervals. Reducing in-house team members from 9 to 5 increased the fraction of patients treated too late by 2.5% as compared to the baseline scenario. Substantially more OR and anesthesia nurses were called in from home when needed. The use of safety intervals benefits OR management during nights. Modeling of safety intervals substantially influences the number of emergency patients treated on time. Our case study showed that by modeling safety intervals and applying computer simulation, an OR can reduce its staff on call without jeopardizing patient safety.

  7. Severity of Vision Loss Interacts With Word-Specific Features to Impact Out-Loud Reading in Glaucoma

    PubMed Central

    Mathews, Priya M.; Rubin, Gary S.; McCloskey, Michael; Salek, Sherveen; Ramulu, Pradeep Y.

    2015-01-01

    Purpose. To assess the impact of glaucoma-related vision loss on measures of out-loud reading, including time to say individual words, interval time between consecutive words, lexical errors, skipped words, and repetitions. Methods. Glaucoma subjects (n = 63) with bilateral visual field loss and glaucoma suspect controls (n = 57) were recorded while reading a standardized passage out loud. A masked evaluator determined the start and end of each recorded word and identified reading errors. Results. Glaucoma subjects demonstrated longer durations to recite individual words (265 vs. 243 ms, P < 0.001), longer intervals between words (154 vs. 124 ms, P < 0.001), and longer word/post-word interval complexes (the time spanned by the word and the interval following the word; 419 vs. 367 ms, P < 0.001) than controls. In multivariable analyses, each 0.1 decrement in log contrast sensitivity (logCS) was associated with a 15.0 ms longer word/post-interval complex (95% confidence interval [CI] = 9.6–20.4; P < 0.001). Contrast sensitivity was found to significantly interact with word length, word frequency, and word location at the end of a line with regards to word/post-word interval complex duration (P < 0.05 for all). Glaucoma severity was also associated with more lexical errors (Odds ratio = 1.20 for every 0.1 logCS decrement; 95% CI = 1.02–1.39, P < 0.05), but not with more skipped or repeated words. Conclusions. Glaucoma patients with greater vision loss make more lexical errors, are slower in reciting longer and less frequently used words, and more slowly transition to new lines of text. These problem areas may require special attention when designing methods to rehabilitate reading in patients with glaucoma. PMID:25737150

  8. High-precision optical measurement of the 2S hyperfine interval in atomic hydrogen.

    PubMed

    Kolachevsky, N; Fischer, M; Karshenboim, S G; Hänsch, T W

    2004-01-23

    We have applied an optical method to the measurement of the 2S hyperfine interval in atomic hydrogen. The interval has been measured by means of two-photon spectroscopy of the 1S-2S transition on a hydrogen atomic beam shielded from external magnetic fields. The measured value of the 2S hyperfine interval is equal to 177 556 860(16) Hz and represents the most precise measurement of this interval to date. The theoretical evaluation of the specific combination of 1S and 2S hyperfine intervals D21 is in fair agreement (within 1.4 sigma) with the value for D21 deduced from our measurement.

  9. A 3.9 ps Time-Interval RMS Precision Time-to-Digital Converter Using a Dual-Sampling Method in an UltraScale FPGA

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Liu, Chong

    2016-10-01

    Field programmable gate arrays (FPGAs) manufactured with more advanced processing technology have faster carry chains and smaller delay elements, which are favorable for the design of tapped delay line (TDL)-style time-to-digital converters (TDCs) in FPGA. However, new challenges are posed in using them to implement TDCs with a high time precision. In this paper, we propose a bin realignment method and a dual-sampling method for TDC implementation in a Xilinx UltraScale FPGA. The former realigns the disordered time delay taps so that the TDC precision can approach the limit of its delay granularity, while the latter doubles the number of taps in the delay line so that the TDC precision beyond the cell delay limitation can be expected. Two TDC channels were implemented in a Kintex UltraScale FPGA, and the effectiveness of the new methods was evaluated. For fixed time intervals in the range from 0 to 440 ns, the average RMS precision measured by the two TDC channels reaches 5.8 ps using the bin realignment, and it further improves to 3.9 ps by using the dual-sampling method. The time precision has a 5.6% variation in the measured temperature range. Every part of the TDC, including dual-sampling, encoding, and on-line calibration, could run at a 500 MHz clock frequency. The system measurement dead time is only 4 ns.

  10. Effective data validation of high-frequency data: time-point-, time-interval-, and trend-based methods.

    PubMed

    Horn, W; Miksch, S; Egghart, G; Popow, C; Paky, F

    1997-09-01

    Real-time systems for monitoring and therapy planning, which receive their data from on-line monitoring equipment and computer-based patient records, require reliable data. Data validation has to utilize and combine a set of fast methods to detect, eliminate, and repair faulty data, which may lead to life-threatening conclusions. The strength of data validation results from the combination of numerical and knowledge-based methods applied to both continuously-assessed high-frequency data and discontinuously-assessed data. Dealing with high-frequency data, examining single measurements is not sufficient. It is essential to take into account the behavior of parameters over time. We present time-point-, time-interval-, and trend-based methods for validation and repair. These are complemented by time-independent methods for determining an overall reliability of measurements. The data validation benefits from the temporal data-abstraction process, which provides automatically derived qualitative values and patterns. The temporal abstraction is oriented on a context-sensitive and expectation-guided principle. Additional knowledge derived from domain experts forms an essential part for all of these methods. The methods are applied in the field of artificial ventilation of newborn infants. Examples from the real-time monitoring and therapy-planning system VIE-VENT illustrate the usefulness and effectiveness of the methods.

  11. Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Amer, Tahani; Tripp, John; Tcheng, Ping; Burkett, Cecil; Sealey, Bradley

    2004-01-01

    This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

  12. A nondestructive method for continuously monitoring plant growth.

    PubMed

    Schwartzkopf, S H

    1985-06-01

    In the past, plant growth generally has been measured using destructive methods. This paper describes a nondestructive technique for continuously monitoring plant growth. The technique provides a means of directly and accurately measuring plant growth over both short and long time intervals. Application of this technique to the direct measurement of plant growth rates is illustrated using corn (Zea mays L.) as an example.

  13. A high-order time-accurate interrogation method for time-resolved PIV

    NASA Astrophysics Data System (ADS)

    Lynch, Kyle; Scarano, Fulvio

    2013-03-01

    A novel method is introduced for increasing the accuracy and extending the dynamic range of time-resolved particle image velocimetry (PIV). The approach extends the concept of particle tracking velocimetry by multiple frames to the pattern tracking by cross-correlation analysis as employed in PIV. The working principle is based on tracking the patterned fluid element, within a chosen interrogation window, along its individual trajectory throughout an image sequence. In contrast to image-pair interrogation methods, the fluid trajectory correlation concept deals with variable velocity along curved trajectories and non-zero tangential acceleration during the observed time interval. As a result, the velocity magnitude and its direction are allowed to evolve in a nonlinear fashion along the fluid element trajectory. The continuum deformation (namely spatial derivatives of the velocity vector) is accounted for by adopting local image deformation. The principle offers important reductions of the measurement error based on three main points: by enlarging the temporal measurement interval, the relative error becomes reduced; secondly, the random and peak-locking errors are reduced by the use of least-squares polynomial fits to individual trajectories; finally, the introduction of high-order (nonlinear) fitting functions provides the basis for reducing the truncation error. Lastly, the instantaneous velocity is evaluated as the temporal derivative of the polynomial representation of the fluid parcel position in time. The principal features of this algorithm are compared with a single-pair iterative image deformation method. Synthetic image sequences are considered with steady flow (translation, shear and rotation) illustrating the increase of measurement precision. An experimental data set obtained by time-resolved PIV measurements of a circular jet is used to verify the robustness of the method on image sequences affected by camera noise and three-dimensional motions. In both cases, it is demonstrated that the measurement time interval can be significantly extended without compromising the correlation signal-to-noise ratio and with no increase of the truncation error. The increase of velocity dynamic range scales more than linearly with the number of frames included for the analysis, which supersedes by one order of magnitude the pair correlation by window deformation. The main factors influencing the performance of the method are discussed, namely the number of images composing the sequence and the polynomial order chosen to represent the motion throughout the trajectory.

  14. Empirical estimation of a distribution function with truncated and doubly interval-censored data and its application to AIDS studies.

    PubMed

    Sun, J

    1995-09-01

    In this paper we discuss the non-parametric estimation of a distribution function based on incomplete data for which the measurement origin of a survival time or the date of enrollment in a study is known only to belong to an interval. Also the survival time of interest itself is observed from a truncated distribution and is known only to lie in an interval. To estimate the distribution function, a simple self-consistency algorithm, a generalization of Turnbull's (1976, Journal of the Royal Statistical Association, Series B 38, 290-295) self-consistency algorithm, is proposed. This method is then used to analyze two AIDS cohort studies, for which direct use of the EM algorithm (Dempster, Laird and Rubin, 1976, Journal of the Royal Statistical Association, Series B 39, 1-38), which is computationally complicated, has previously been the usual method of the analysis.

  15. Measuring discharge with ADCPs: Inferences from synthetic velocity profiles

    USGS Publications Warehouse

    Rehmann, C.R.; Mueller, D.S.; Oberg, K.A.

    2009-01-01

    Synthetic velocity profiles are used to determine guidelines for sampling discharge with acoustic Doppler current profilers (ADCPs). The analysis allows the effects of instrument characteristics, sampling parameters, and properties of the flow to be studied systematically. For mid-section measurements, the averaging time required for a single profile measurement always exceeded the 40 s usually recommended for velocity measurements, and it increased with increasing sample interval and increasing time scale of the large eddies. Similarly, simulations of transect measurements show that discharge error decreases as the number of large eddies sampled increases. The simulations allow sampling criteria that account for the physics of the flow to be developed. ?? 2009 ASCE.

  16. What role do plain radiographs have in assessing the skeletally immature acromioclavicular joint?

    PubMed

    Lee, Seung Yeol; Kwon, Soon-Sun; Chung, Chin Youb; Lee, Kyoung Min; Park, Moon Seok

    2014-01-01

    Because of incomplete ossification of the coracoid process and acromion, acromioclavicular joint configuration in the skeletally immature patient differs from that of adults. Although comparison to radiographic standards for this joint is critical in the evaluation of acromioclavicular joint injuries, these standards are not well defined for children or adolescents. We therefore sought to determine (1) the reliability of numerous radiographic measurements of the skeletally immature acromioclavicular joint, including the vertical and shortest coracoclavicular interval, and the acromioclavicular joint offset; (2) the timing of ossification of the acromion and coracoid in males and females; and (3) the differences in the values of these radiographic measurements based on age and sex. This study was based on a total of 485 subjects, 8 to 18 years old, who underwent conventional AP view radiographs of both shoulders. The 485 subjects were included to assess normal configuration around the acromioclavicular joint and 466 of these subjects were evaluated for comparison between both sides. The vertical and shortest coracoclavicular interval, coracoclavicular clavicle width ratio, acromioclavicular joint offset, and difference of the coracoclavicular interval of both sides were measured. A reliability test was conducted before obtaining the main measurements. The relationship of measurements with sex, age, and stage of ossification was evaluated. The vertical and shortest coracoclavicular interval showed excellent reliability (intraclass correlation coefficient ([ICC], 0.918 and 0.934). The acromioclavicular joint offset showed low reliability (ICC, 0.543). The ossification centers of the acromion and the coracoid processes appeared and fused earlier in females than in males. The vertical coracoclavicular interval, which was not affected by partial ossification of the coracoid process, was less than 11 mm in the 90% quantile of total subjects in males and 10 mm in the 90% quantile in females. The difference of the vertical coracoclavicular interval of both sides was less than 50% in 436 of 466 (93.4%) patients. The vertical coracoclavicular interval was the best parameter to assess acromioclavicular joint dislocation in skeletally immature patients. Comparison of both sides of the acromioclavicular joint could help to inform physicians in predicting the need for additional evaluations.

  17. Measuring skew in average surface roughness as a function of surface preparation

    NASA Astrophysics Data System (ADS)

    Stahl, Mark T.

    2015-08-01

    Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo® white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.

  18. Measuring the impact of cataract surgery on generic and vision-specific quality of life.

    PubMed

    Groessl, Erik J; Liu, Lin; Sklar, Marisa; Tally, Steven R; Kaplan, Robert M; Ganiats, Theodore G

    2013-08-01

    Cataracts are the leading cause of blindness worldwide and cause visual impairment for millions of adults in the United States. We compared the sensitivity of a vision-specific health-related quality of life (HRQOL) measure to that of multiple generic measures of HRQOL before and at 2 time points after cataract surgery. Participants completed 1 vision-specific and 5 generic quality of life measures before cataract surgery, and again 1 and 6 months after surgery. Random effects modeling was used to measure changes over the three assessment points. The NEI-VFQ25 total score and all 11 subscales showed significant improvements during the first interval (baseline and 1 month). During the second interval (1-6 months post-surgery), significant improvements were observed on the total score and 5 of 11 NEI-VFQ25 subscales. There were significant increases in HRQOL during the first interval on some preference-based generic HRQOL measures, though changes during the second interval were mostly non-significant. None of the SF-36v2™ or SF6D scales changed significantly between any of the assessment periods. The NEI-VFQ25 was sensitive to changes in vision-specific domains of QOL. Some preference-based generic HRQOL measures were also sensitive to change and showed convergence with the NEI-VFQ25, but the effects were small. The SF-36v2™ and SF-6D did not change in a similar manner, possibly reflecting a lack of vision-related content. Studies seeking to document both the vision-specific and generic HRQOL improvements of cataract surgery should consider these results when selecting measures.

  19. Application of carbon nanotube hold-off voltage for determining gas composition

    NASA Technical Reports Server (NTRS)

    Schipper, John F. (Inventor); Li, Jing (Inventor)

    2009-01-01

    Method and system for determining chemical composition of a single-component or multiple-component gas, using a discharge holdoff mechanism. A voltage difference V between two spaced apart electrodes is brought to a selected value and held, the holdoff time interval .DELTA.t(V;ho) required before gas discharge occurs is measured, and the associated electrical current or cumulative electrical charge is measured. As the voltage difference V increases, the time interval length .DELTA.t(V;ho) decreases monotonically. Particular voltage values, V.sub..infin. and V.sub.0, correspond to initial appearance of discharge (.DELTA.t.apprxeq..infin.) and prompt discharge (.DELTA.t.apprxeq.0). The values V.sub..infin. and V.sub.0 and the rate of decrease of .DELTA.t(V;ho) and/or the rate of increase of current or cumulative charge with increasing V are characteristic of one or more gas components present.

  20. Photon time-interval statistics applied to the analysis of laser heterodyne signal with photon counter

    NASA Astrophysics Data System (ADS)

    Liu, Lisheng; Zhang, Heyong; Guo, Jin; Zhao, Shuai; Wang, Tingfeng

    2012-08-01

    In this paper, we report a mathematical derivation of probability density function (PDF) of time-interval between two successive photoelectrons of the laser heterodyne signal, and give a confirmation of the theoretical result by both numerical simulation and an experiment. The PDF curve of the beat signal displays a series of fluctuations, the period and amplitude of which are respectively determined by the beat frequency and the mixing efficiency. The beat frequency is derived from the frequency of fluctuations accordingly when the PDF curve is measured. This frequency measurement method still works while the traditional Fast Fourier Transform (FFT) algorithm hardly derives the correct peak value of the beat frequency in the condition that we detect 80 MHz beat signal with 8 Mcps (counts per-second) photons count rate, and this indicates an advantage of the PDF method.

  1. Circulating intact and cleaved forms of the urokinase-type plasminogen activator receptor: biological variation, reference intervals and clinical useful cut-points.

    PubMed

    Thurison, Tine; Christensen, Ib J; Lund, Ida K; Nielsen, Hans J; Høyer-Hansen, Gunilla

    2015-01-15

    High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Development and validation of a very brief questionnaire measure of physical activity in adults with coronary heart disease.

    PubMed

    Orrell, Alison; Doherty, Patrick; Miles, Jeremy; Lewin, Robert

    2007-10-01

    The aim of this study was to validate the Total Activity Measure, a brief questionnaire, to measure physical activity in an older adult population with heart disease. Two versions of the Total Activity Measure were administered twice, 7 days apart. The Total Activity Measure 1 asked respondents for the frequency and average duration of bouts of physical activity at three different intensity levels per week, whereas the Total Activity Measure 2 asked respondents for the total time spent in activity at each activity level per week. Questionnaire accuracy was studied in 62 men and 15 women aged 47-84 years, by repeatability and comparison of both administrations of the Total Activity Measure 1 and Total Activity Measure 2 with 7-day RT3 accelerometer data. Seventy-three adults (58 men, 15 women) were used for all statistical analyses. Intraclass correlation coefficients for the Total Activity Measure 1 and Total Activity Measure 2 total activity scores (metabolic equivalent per minute) were r=0.73 (95% confidence intervals, 0.56-0.83) and r=0.82 (95% confidence intervals, 0.71-0.88), respectively. Correlations between the Total Activity Measure 1 and RT3 accelerometer for total activity score (metabolic equivalent per minute) were significant, r=0.26 at time 1 and r=0.27 at time 2 for moderate intensity activities. Correlations between the Total Activity Measure 2 and RT3 accelerometer for total activity score (metabolic equivalent per minute) were also significant, r=0.38 at time 1 and r=0.36 at time 2, r=0.31 at time 2 for strenuous intensity activities and r=0.29 at time 1 and r=0.25 at time 2 for moderate intensity activities. Participants overestimated the amount of physical activity on both questionnaires as compared with the RT3 accelerometer. The Total Activity Measure 2 was reasonably accurate in assessing total and moderate intensity activity over a 7-day period and demonstrated good test-retest reliability. The Total Activity Measure 1 was less accurate. The Total Activity Measure 2 is a suitable measure of total or moderate intensity physical activity for surveys and audits in an adult cardiac population.

  3. Cardioventilatory coupling in preterm and term infants: effect of position and sleep state.

    PubMed

    Elder, Dawn E; Larsen, Peter D; Galletly, Duncan C; Campbell, Angela J

    2010-11-30

    This study documented the effect of position on cardioventilatory coupling (CVC), the triggering of inspiratory onset by a preceding heartbeat, in infants. Cardiorespiratory signals and corresponding oxygen saturation (SpO(2)) were downloaded from Quiet Sleep (QS) and Active Sleep (AS) in prone and supine from preterm (PT) and term (T) infants. Inspiratory onsets (I) and timing of the corresponding ECG R wave were determined and R-R and R-I intervals calculated. The RI(-1) interval (time between inspiration and the preceding R wave) dispersion was measured using proportional Shannon Entropy of the RI(-1) interval (SH(α)), to provide a quantitative measure of CVC. CVC was more frequently seen in QS in PT (p=0.002) and T (p=0.02) infants but not influenced by position (p=0.71, p=0.46). CVC correlated with SpO(2) in PT (r=-0.230, p=0.03) but not T infants (r=0.085, p=0.34). These data imply an augmentation of cardiac influence on ventilatory rhythm in infants in QS. In preterm infants CVC may have a role in supporting oxygenation. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Real time spectrometer for thermal neutrons from radiotherapic accelerators

    NASA Astrophysics Data System (ADS)

    Mozzanica, A.; Bartesaghi, G.; Bolognini, D.; Conti, V.; Mascagna, V.; Prest, M.; Scazzi, S.; Cappelletti, P.; Frigerio, M.; Gelosa, S.; Monti, A.; Ostinelli, A.; Bevilacqua, R.; Giannini, G.; Totaro, P.; Vallazza, E.

    2007-10-01

    Radiotherapy accelerators can produce high energy photon beams for deep tumour treatments. Photons with energies greater than 8 MeV produce neutrons via photoproduction. The PHONES (PHOto NEutron Source) project is developing a neutron moderator to use the photoproduced neutrons for BNCT (Boron Neutron Capture Therapy) in hospital environments. In this framework we are developing a real time spectrometer for thermal neutrons exploiting the bunch structure of the beam. Since the beam is produced by a linear accelerator, in fact, particles are sent to the patient in bunches with a rate of 150-300 Hz depending on the beam type and energy. The neutron spectrum is usually measured with integrating detectors such as bubble dosimeters or TLDs, which integrate over a time interval and an energy one. We are developing a scintillator detector to measure the neutron spectrum in real time in the interval between bunches, that is in the thermal region. The signals from the scintillator are discriminated and sampled by a dedicated clock in a Cyclone II FPGA by Altera, thus obtaining the neutron time of flight spectrum. The exploited physical process in ordinary plastic scintillators is neutron capture by H with a subsequent γ emission. The measured TOF spectrum has been compared with a BF 3 counter one. A dedicated simulation with MCNP is being developed to extract the energy spectrum from the TOF one. The paper will present the results of the prototype measurements and the status of the simulation.

  5. Alignment of time-resolved data from high throughput experiments.

    PubMed

    Abidi, Nada; Franke, Raimo; Findeisen, Peter; Klawonn, Frank

    2016-12-01

    To better understand the dynamics of the underlying processes in cells, it is necessary to take measurements over a time course. Modern high-throughput technologies are often used for this purpose to measure the behavior of cell products like metabolites, peptides, proteins, [Formula: see text]RNA or mRNA at different points in time. Compared to classical time series, the number of time points is usually very limited and the measurements are taken at irregular time intervals. The main reasons for this are the costs of the experiments and the fact that the dynamic behavior usually shows a strong reaction and fast changes shortly after a stimulus and then slowly converges to a certain stable state. Another reason might simply be missing values. It is common to repeat the experiments and to have replicates in order to carry out a more reliable analysis. The ideal assumptions that the initial stimulus really started exactly at the same time for all replicates and that the replicates are perfectly synchronized are seldom satisfied. Therefore, there is a need to first adjust or align the time-resolved data before further analysis is carried out. Dynamic time warping (DTW) is considered as one of the common alignment techniques for time series data with equidistant time points. In this paper, we modified the DTW algorithm so that it can align sequences with measurements at different, non-equidistant time points with large gaps in between. This type of data is usually known as time-resolved data characterized by irregular time intervals between measurements as well as non-identical time points for different replicates. This new algorithm can be easily used to align time-resolved data from high-throughput experiments and to come across existing problems such as time scarcity and existing noise in the measurements. We propose a modified method of DTW to adapt requirements imposed by time-resolved data by use of monotone cubic interpolation splines. Our presented approach provides a nonlinear alignment of two sequences that neither need to have equi-distant time points nor measurements at identical time points. The proposed method is evaluated with artificial as well as real data. The software is available as an R package tra (Time-Resolved data Alignment) which is freely available at: http://public.ostfalia.de/klawonn/tra.zip .

  6. High-frequency rock temperature data from hyper-arid desert environments in the Atacama and the Antarctic Dry Valleys and implications for rock weathering

    NASA Astrophysics Data System (ADS)

    McKay, Christopher P.; Molaro, Jamie L.; Marinova, Margarita M.

    2009-09-01

    In desert environments with low water and salt contents, rapid thermal variations may be an important source of rock weathering. We have obtained temperature measurements of the surface of rocks in hyper-arid hot and cold desert environments at a rate of 1/s over several days. The values of temperature change over 1-second intervals were similar in hot and cold deserts despite a 30 °C difference in absolute rock surface temperature. The average percentage of the time dT/dt > 2 °C/min was ~ 8 ± 3%, > 4 °C/min was 1 ± 0.9%, and > 8 °C/min was 0.02 ± 0.03%. The maximum change over a 1-second interval was ~ 10 °C/min. When sampled to simulate data taken over intervals longer than 1 s, we found a reduction in time spent above the 2 °C/min temperature gradient threshold. For 1-minute samples, the time spent above any given threshold was about two orders of magnitude lower than the corresponding value for 1-second sampling. We suggest that a rough measure of efficacy of weathering as a function of frequency is the product of the percentage of time spent above a given threshold value multiplied by the damping depth for the corresponding frequency. This product has a broad maximum for periods between 3 and 10 s.

  7. [Changes in heart rate variability after myocardial infarction. Value of Poincareé's diagram].

    PubMed

    Copie, X; Le Heuzey, J Y; Iliou, M C; Pousset, F; Lavergne, T; Guize, L

    1995-11-01

    The variability of the heart rate is reduced after myocardial infarction. It then progressively increases, to return to near normal values after several months. However, these changes in heart rate variability occur at the same time as slowing of the heart rate which makes interpretation difficult. Poincaré's diagram is constructed from a Holter recording plotting each RR interval against the preceding RR interval. The authors have developed a geometric approach to this diagram to evaluate parasympathetic tone for a given heart rate. By measuring the dispersion in height of the Poincaré's diagram, the authors evaluate the shor-term variability for a given RR interval. Two 24 hr Holter recordings were performed in 52 patients at one and two weeks after a myocardial infarction. The dispersion in the height of the Poincaré's diagrams was measured at the 10th, 25th, 50th, 75th and 90th percentiles of the total dispersion. The authors have shown an increase in the short-term variability of the shortest RR intervals (1th, 25th and 50th percentiles) which is not observed in the longer RR intervals (75th and 90th percentiles). In conclusion, theres is an increase in the heart rate variability at the shortest RR intervals. This suggests that the recovery of parasympathic tone after myocardial infarction occurs mainly at the fastest heart rates.

  8. Urinary tract infection-like symptom is associated with worse bladder cancer outcomes in the Medicare population: Implications for sex disparities.

    PubMed

    Richards, Kyle A; Ham, Sandra; Cohn, Joshua A; Steinberg, Gary D

    2016-01-01

    To determine the time to bladder cancer diagnosis from initial infection-like symptoms and its impact on cancer outcomes. Using Surveillance, Epidemiology and End Results-Medicare, we designed a retrospective cohort study identifying beneficiaries aged ≥ 66 years diagnosed with bladder cancer from 2007 to 2009. Patients were required to have a hematuria or urinary tract infection claim within 1 year of bladder cancer diagnosis (n = 21 216), and have 2 years of prior Medicare data (n = 18 956) without any precedent hematuria, bladder cancer or urinary tract infection claims (n = 12 195). The number of days to bladder cancer diagnosis was measured, as well as the impact of sex and presenting symptom on time to diagnosis, pathology, and oncological outcomes. The mean time to bladder cancer diagnosis was 72.2 days in women versus 58.9 days in men (P < 0.001). A logistic regression model identified the greatest predictors of ≥ pT2 pathology were both women (odds ratio 2.08, 95% confidence interval 1.70-2.55) and men (odds ratio 1.71, 95% confidence interval 1.49-1.97) presenting with urinary tract infection. Cox proportional hazards analysis identified an increased risk of mortality from bladder cancer and all causes in women presenting with urinary tract infection (hazard ratio 1.37, 95% confidence interval 1.10-1.71, and hazard ratio 1.47, 95% confidence interval 1.28-1.69) compared with women with hematuria. Women have a longer interval from urinary tract infection to diagnosis of bladder cancer. Urinary tract infection presentation can adversely affect time to diagnosis, pathology and survival. Time to diagnosis seems not to be an independent predictor of bladder cancer outcomes. © 2015 The Japanese Urological Association.

  9. A comparative evaluation of the marginal adaptation of a thermoplastic resin, a light cured wax and an inlay casting wax on stone dies: An in vitro study.

    PubMed

    Gopalan, Reji P; Nair, Vivek V; Harshakumar, K; Ravichandran, R; Lylajam, S; Viswambaran, Prasanth

    2018-01-01

    Different pattern materials do not produce copings with satisfactory, marginal accuracy when used on stone dies at varying time intervals. The purpose of this study was to evaluate and compare the vertical marginal accuracy of patterns formed from three materials, namely, thermoplastic resin, light cured wax and inlay casting wax at three-time intervals of 1, 12, and 24 h. A master die (zirconia abutment mimicking a prepared permanent maxillary central incisor) and metal sleeve (direct metal laser sintering crown #11) were fabricated. A total of 30 stone dies were obtained from the master die. Ten patterns were made each from the three materials and stored off the die at room temperature. The vertical marginal gaps were measured using digital microscope at 1, 12, and 24 h after reseating with gentle finger pressure. The results revealed a significant statistical difference in the marginal adaptation of three materials at all the three-time intervals. Light cured wax was found to be most accurate at all time intervals, followed by thermoplastic resin and inlay casting wax. Furthermore, there was a significant difference between all pairs of materials. The change in vertical marginal gap from 1 to 24 h between thermoplastic resin and light cured wax was not statistically significant. The marginal adaptation of all the three materials used, was well within the acceptable range of 25-70 μm. The resin pattern materials studied revealed significantly less dimensional change than inlay casting wax on storage at 1, 12, and 24 h time intervals. They may be employed in situations where high precision and delayed investing is expected.

  10. Measurement of transpiration in Pinus taeda L. and Liquidambar styraciflua L. in an environmental chamber using tritiated water

    NASA Technical Reports Server (NTRS)

    Levy, G. F.; Sonenshine, D. E.; Czoch, J. K.

    1976-01-01

    Transpiration rates of loblolly pine (Pinus taeda L.) and sweetgum (Liquidambar styraciflua L.) were measured at two different atmospheric water vapor pressure deficits (V.P.D.) in a controlled environment growth chamber using tritiated water as a tracer. The trees were maintained in a sealed plant bed containing a hydroponic nutrient solution into which labeled water (spike) was introduced. Samples of leaves, chamber air, spiked nutrient solution and control water were assayed for ratio-activity using liquid scintillation techniques to determine transpiration rates. The transpiration rate of sweetgum in ml./hr./gm. (4.95) was found to be 5 times greater than that of loblolly pine (1.03) at 1.84 V.P.D. and 8 times greater at 6.74 V.P.D. (15.99 for sweetgum vs. 2.19 for pine). Transpiration (based on measurements of leaf radioactivity) in both species rose with increasing deficit; however sweetgum increased its output by 3 times while pine only doubled its rate. Cyclical changes in transpiration rates were noted in both species; the sweetgum cycle required a 6 hour interval whereas the pine cycle required a 9 hour interval.

  11. Thermal comfort and safety of cotton blankets warmed at 130°F and 200°F.

    PubMed

    Kelly, Patricia A; Cooper, Susan K; Krogh, Mary L; Morse, Elizabeth C; Crandall, Craig G; Winslow, Elizabeth H; Balluck, Julie P

    2013-12-01

    In 2009, the ECRI Institute recommended warming cotton blankets in cabinets set at 130°F or less. However, there is limited research to support the use of this cabinet temperature. To measure skin temperatures and thermal comfort in healthy volunteers before and after application of blankets warmed in cabinets set at 130 and 200°F, respectively, and to determine the time-dependent cooling of cotton blankets after removal from warming cabinets set at the two temperatures. Prospective, comparative, descriptive. Participants (n = 20) received one or two blankets warmed in 130 or 200°F cabinets. First, skin temperatures were measured, and thermal comfort reports were obtained at fixed timed intervals. Second, blanket temperatures (n = 10) were measured at fixed intervals after removal from the cabinets. No skin temperatures approached levels reported in the literature that cause epidermal damage. Thermal comfort reports supported using blankets from the 200°F cabinet, and blankets lost heat quickly over time. We recommend warming cotton blankets in cabinets set at 200°F or less to improve thermal comfort without compromising patient safety. Copyright © 2013 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  12. Real-time flutter boundary prediction based on time series models

    NASA Astrophysics Data System (ADS)

    Gu, Wenjing; Zhou, Li

    2018-03-01

    For the purpose of predicting the flutter boundary in real time during flutter flight tests, two time series models accompanied with corresponding stability criterion are adopted in this paper. The first method simplifies a long nonstationary response signal as many contiguous intervals and each is considered to be stationary. The traditional AR model is then established to represent each interval of signal sequence. While the second employs a time-varying AR model to characterize actual measured signals in flutter test with progression variable speed (FTPVS). To predict the flutter boundary, stability parameters are formulated by the identified AR coefficients combined with Jury's stability criterion. The behavior of the parameters is examined using both simulated and wind-tunnel experiment data. The results demonstrate that both methods show significant effectiveness in predicting the flutter boundary at lower speed level. A comparison between the two methods is also given in this paper.

  13. Evaluation of emergency department performance – a systematic review on recommended performance and quality-in-care measures

    PubMed Central

    2013-01-01

    Background Evaluation of emergency department (ED) performance remains a difficult task due to the lack of consensus on performance measures that reflects high quality, efficiency, and sustainability. Aim To describe, map, and critically evaluate which performance measures that the published literature regard as being most relevant in assessing overall ED performance. Methods Following the PRISMA guidelines, a systematic literature review of review articles reporting accentuated ED performance measures was conducted in the databases of PubMed, Cochrane Library, and Web of Science. Study eligibility criteria includes: 1) the main purpose was to discuss, analyse, or promote performance measures best reflecting ED performance, 2) the article was a review article, and 3) the article reported macro-level performance measures, thus reflecting an overall departmental performance level. Results A number of articles addresses this study’s objective (n = 14 of 46 unique hits). Time intervals and patient-related measures were dominant in the identified performance measures in review articles from US, UK, Sweden and Canada. Length of stay (LOS), time between patient arrival to initial clinical assessment, and time between patient arrivals to admission were highlighted by the majority of articles. Concurrently, “patients left without being seen” (LWBS), unplanned re-attendance within a maximum of 72 hours, mortality/morbidity, and number of unintended incidents were the most highlighted performance measures that related directly to the patient. Performance measures related to employees were only stated in two of the 14 included articles. Conclusions A total of 55 ED performance measures were identified. ED time intervals were the most recommended performance measures followed by patient centeredness and safety performance measures. ED employee related performance measures were rarely mentioned in the investigated literature. The study’s results allow for advancement towards improved performance measurement and standardised assessment across EDs. PMID:23938117

  14. A gravimetric technique for evaluating flow continuity from two infusion devices.

    PubMed

    Leff, R D; True, W R; Roberts, R J

    1987-06-01

    A computerized gravimetric technique for examining the flow continuity from infusion devices was developed, and two infusion devices with different mechanisms of pump operation were evaluated to illustrate this technique. A BASIC program that records serial weight measurements and calculates weight change from previous determinations was written for and interfaced with a gravimetric balance and IBM PC. A plot of effused weight (normalized weight change that reflects the difference between desired timed-sample interval and actual time) versus time (desired timed-sample interval) was constructed. The gravimetric technique was evaluated using both a peristaltic-type and a piston-type infusion pump. Intravenous solution (5% dextrose and 0.9% sodium chloride) was effused at 10 mL/hr and collected in a beaker. Weights were measured at 10-second intervals over a two-hour infusion period, and the weights of the effused solution were plotted versus time. Flow continuity differed between the two infusion devices. Actual effused weight decreased to 0.007 g/10 sec during the refill cycle of the piston-type pump; the mean (+/- S.D.) effused weight was 0.029 +/- 0.002 g/10 sec. The desired effusion rate was 0.028 g/10 sec. The peristaltic pump had greater flow continuity, with a mean effusion weight of 0.028 +/- 0.003 g/10 sec. The gravimetric technique described in this report can be used to quantitatively depict the effusion profiles of infusion devices. Further studies are needed to identify the degree of flow continuity that is clinically acceptable for infusion devices.

  15. Solar cycle variations in polar cap area measured by the superDARN radars

    NASA Astrophysics Data System (ADS)

    Imber, S. M.; Milan, S. E.; Lester, M.

    2013-10-01

    present a long-term study, from January 1996 to August 2012, of the latitude of the Heppner-Maynard Boundary (HMB) measured at midnight using the northern hemisphere Super Dual Auroral Radar Network (SuperDARN). The HMB represents the equatorward extent of ionospheric convection and is used in this study as a measure of the global magnetospheric dynamics. We find that the yearly distribution of HMB latitudes is single peaked at 64° magnetic latitude for the majority of the 17 year interval. During 2003, the envelope of the distribution shifts to lower latitudes and a second peak in the distribution is observed at 61°. The solar wind-magnetosphere coupling function derived by Milan et al. (2012) suggests that the solar wind driving during this year was significantly higher than during the rest of the 17 year interval. In contrast, during the period 2008-2011, HMB distribution shifts to higher latitudes, and a second peak in the distribution is again observed, this time at 68° magnetic latitude. This time interval corresponds to a period of extremely low solar wind driving during the recent extreme solar minimum. This is the first long-term study of the polar cap area and the results demonstrate that there is a close relationship between the solar activity cycle and the area of the polar cap on a large-scale, statistical basis.

  16. Solar Cycle Variations in Polar Cap Area Measured by the SuperDARN Radars

    NASA Astrophysics Data System (ADS)

    Imber, S. M.; Milan, S. E.; Lester, M.

    2013-12-01

    We present a long term study, from January 1996 - August 2012, of the latitude of the Heppner-Maynard Boundary (HMB) measured at midnight using the northern hemisphere SuperDARN radars. The HMB represents the equatorward extent of ionospheric convection, and is used in this study as a measure of the global magnetospheric dynamics and activity. We find that the yearly distribution of HMB latitudes is single-peaked at 64° magnetic latitude for the majority of the 17-year interval. During 2003 the envelope of the distribution shifts to lower latitudes and a second peak in the distribution is observed at 61°. The solar wind-magnetosphere coupling function derived by Milan et al. (2012) suggests that the solar wind driving during this year was significantly higher than during the rest of the 17-year interval. In contrast, during the period 2008-2011 HMB distribution shifts to higher latitudes, and a second peak in the distribution is again observed, this time at 68° magnetic latitude. This time interval corresponds to a period of extremely low solar wind driving during the recent extreme solar minimum. This is the first statistical study of the polar cap area over an entire solar cycle, and the results demonstrate that there is a close relationship between the phase of the solar cycle and the area of the polar cap on a large scale statistical basis.

  17. Selecting Sensitive Parameter Subsets in Dynamical Models With Application to Biomechanical System Identification.

    PubMed

    Ramadan, Ahmed; Boss, Connor; Choi, Jongeun; Peter Reeves, N; Cholewicki, Jacek; Popovich, John M; Radcliffe, Clark J

    2018-07-01

    Estimating many parameters of biomechanical systems with limited data may achieve good fit but may also increase 95% confidence intervals in parameter estimates. This results in poor identifiability in the estimation problem. Therefore, we propose a novel method to select sensitive biomechanical model parameters that should be estimated, while fixing the remaining parameters to values obtained from preliminary estimation. Our method relies on identifying the parameters to which the measurement output is most sensitive. The proposed method is based on the Fisher information matrix (FIM). It was compared against the nonlinear least absolute shrinkage and selection operator (LASSO) method to guide modelers on the pros and cons of our FIM method. We present an application identifying a biomechanical parametric model of a head position-tracking task for ten human subjects. Using measured data, our method (1) reduced model complexity by only requiring five out of twelve parameters to be estimated, (2) significantly reduced parameter 95% confidence intervals by up to 89% of the original confidence interval, (3) maintained goodness of fit measured by variance accounted for (VAF) at 82%, (4) reduced computation time, where our FIM method was 164 times faster than the LASSO method, and (5) selected similar sensitive parameters to the LASSO method, where three out of five selected sensitive parameters were shared by FIM and LASSO methods.

  18. Designing a Simple Apparatus for Measuring Kinematic Variables

    ERIC Educational Resources Information Center

    Temiz, Burak Kagan

    2014-01-01

    This study was conducted to develop a simple and inexpensive experimental apparatus that can measure the position of an object moving along a straight line at certain time intervals. For the construction of the apparatus, a battery-powered toy car, a fine-tipped paint brush, gouache (or watercolour) paint and paper tape were used. The working…

  19. An interpretation of radiosonde errors in the atmospheric boundary layer

    Treesearch

    Bernadette H. Connell; David R. Miller

    1995-01-01

    The authors review sources of error in radiosonde measurements in the atmospheric boundary layer and analyze errors of two radiosonde models manufactured by Atmospheric Instrumentation Research, Inc. The authors focus on temperature and humidity lag errors and wind errors. Errors in measurement of azimuth and elevation angles and pressure over short time intervals and...

  20. Doubling Your Sunsets or How Anyone Can Measure the Earth's Size with Wristwatch and Meterstick.

    ERIC Educational Resources Information Center

    Rawlins, Dennis

    1979-01-01

    Describes a simple method to measure the size of the Earth to an accuracy of order of magnitude 10 percent. The procedure involves finding the time interval between two sunsets, a sunset observed at sea level while lying down, and a sunset viewed at eye height after standing up. (GA)

  1. Analysis of the Factors Affecting the Interval between Blood Donations Using Log-Normal Hazard Model with Gamma Correlated Frailties.

    PubMed

    Tavakol, Najmeh; Kheiri, Soleiman; Sedehi, Morteza

    2016-01-01

    Time to donating blood plays a major role in a regular donor to becoming continues one. The aim of this study was to determine the effective factors on the interval between the blood donations. In a longitudinal study in 2008, 864 samples of first-time donors in Shahrekord Blood Transfusion Center,  capital city of Chaharmahal and Bakhtiari Province, Iran were selected by a systematic sampling and were followed up for five years. Among these samples, a subset of 424 donors who had at least two successful blood donations were chosen for this study and the time intervals between their donations were measured as response variable. Sex, body weight, age, marital status, education, stay and job were recorded as independent variables. Data analysis was performed based on log-normal hazard model with gamma correlated frailty. In this model, the frailties are sum of two independent components assumed a gamma distribution. The analysis was done via Bayesian approach using Markov Chain Monte Carlo algorithm by OpenBUGS. Convergence was checked via Gelman-Rubin criteria using BOA program in R. Age, job and education were significant on chance to donate blood (P<0.05). The chances of blood donation for the higher-aged donors, clericals, workers, free job, students and educated donors were higher and in return, time intervals between their blood donations were shorter. Due to the significance effect of some variables in the log-normal correlated frailty model, it is necessary to plan educational and cultural program to encourage the people with longer inter-donation intervals to donate more frequently.

  2. Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Sigeaki; Toyooka, Satoru

    1995-10-01

    The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.

  3. Viewpoint matters: objective performance metrics for surgeon endoscope control during robot-assisted surgery.

    PubMed

    Jarc, Anthony M; Curet, Myriam J

    2017-03-01

    Effective visualization of the operative field is vital to surgical safety and education. However, additional metrics for visualization are needed to complement other common measures of surgeon proficiency, such as time or errors. Unlike other surgical modalities, robot-assisted minimally invasive surgery (RAMIS) enables data-driven feedback to trainees through measurement of camera adjustments. The purpose of this study was to validate and quantify the importance of novel camera metrics during RAMIS. New (n = 18), intermediate (n = 8), and experienced (n = 13) surgeons completed 25 virtual reality simulation exercises on the da Vinci Surgical System. Three camera metrics were computed for all exercises and compared to conventional efficiency measures. Both camera metrics and efficiency metrics showed construct validity (p < 0.05) across most exercises (camera movement frequency 23/25, camera movement duration 22/25, camera movement interval 19/25, overall score 24/25, completion time 25/25). Camera metrics differentiated new and experienced surgeons across all tasks as well as efficiency metrics. Finally, camera metrics significantly (p < 0.05) correlated with completion time (camera movement frequency 21/25, camera movement duration 21/25, camera movement interval 20/25) and overall score (camera movement frequency 20/25, camera movement duration 19/25, camera movement interval 20/25) for most exercises. We demonstrate construct validity of novel camera metrics and correlation between camera metrics and efficiency metrics across many simulation exercises. We believe camera metrics could be used to improve RAMIS proficiency-based curricula.

  4. A comparison of pairs figure skaters in repeated jumps.

    PubMed

    Sands, William A; Kimmel, Wendy L; McNeal, Jeni R; Murray, Steven Ross; Stone, Michael H

    2012-01-01

    Trends in pairs figure skating have shown that increasingly difficult jumps have become an essential aspect of high-level performance, especially in the latter part of a competitive program. We compared a repeated jump power index in a 60 s repeated jump test to determine the relationship of repeated jump test to competitive rank and to measure 2D hip, knee, and ankle angles and angular velocities at 0, 20, 40, and 60 s. Eighteen National Team Pairs Figure Skaters performed a 60 s repeated jump test on a large switch-mat with timing of flight and ground durations and digital video recording. Each 60-s period was divided into 6, 10-s intervals, with power indexes (W/kg) calculated for each 10-s interval. Power index by 10-s interval repeated measures ANOVAs (RMANOVA) showed that males exceeded females at all intervals, and the highest power index interval was during 10 to 20 s for both sexes. RMANOVAs of angles and angular velocities showed main effects for time only. Power index and jumping techniques among figure skaters showed rapid and steady declines over the test duration. Power index can predict approximately 50% of competitive rank variance, and sex differences in jumping technique were rare. Key pointsThe repeated jumps test can account for about 50% of the variance in pairs ranks.Changes in technique are largely due to fatigue, but the athletes were able to maintain a maximum flexion knee angle very close to the desired 90 degrees. Changes in angular velocity and jump heights occurred as expected, again probably due to fatigue.As expected from metabolic information, the athletes' power indexes peak around 20s and decline thereafter. Coaches should be aware of this time as a boundary beyond which fatigue becomes more manifest, and use careful choreographic choices to provide rest periods that are disguised as less demanding skating elements to afford recovery.The repeated jumps test may be a helpful off-ice test of power-endurance for figure skaters.

  5. Masticatory motion after surgical or nonsurgical treatment for unilateral fractures of the mandibular condylar process.

    PubMed

    Throckmorton, Gaylord S; Ellis, Edward; Hayasaki, Haruaki

    2004-02-01

    We sought to compare mandibular motion during mastication in patients treated in either an open or a closed fashion for unilateral fractures of the mandibular condylar process. Eighty-one male patients with unilateral condylar process fractures were treated either with (n = 37) or without (n = 44) surgical reduction and rigid fixation of their condylar process fractures. At 6 weeks, 6 months, 1 year, and 2 years after treatment, the subjects' chewing cycles were recorded using a magnetic sensor array (Sirognathograph; Siemens Corp, Bensheim, Germany) while chewing Gummi-Bears (HARIBO, Bonn, Germany) unilaterally on the same side as the fracture and on the opposite side. The chewing cycles were analyzed using a custom computer program, and the duration, excursive ranges, and 3-dimensional cycle shape were compared between the 2 treatment groups at each time interval using multilevel linear modeling statistics. The 2 treatment groups did not differ significantly for any measure of cycle duration or any excursive range (except lateral excursions at 1 year post-treatment) at any of the time intervals. However, the 3-dimensional cycle shapes of the 2 groups did differ significantly at all time intervals. Surgical correction of unilateral condylar process fractures has relatively little effect on the more standard measures (duration and excursive ranges) of masticatory function. However, surgical correction better normalizes opening incisor pathways during mastication on the side opposite the fracture.

  6. Acute and chronic respiratory effects of sodium borate particulate exposures.

    PubMed Central

    Wegman, D H; Eisen, E A; Hu, X; Woskie, S R; Smith, R G; Garabrant, D H

    1994-01-01

    This study examined work-related chronic abnormality in pulmonary function and work-related acute irritant symptoms associated with exposure to borate dust in mining and processing operations. Chronic effects were examined by pulmonary function at the beginning and end of a 7-year interval. Time-specific estimates of sodium borate particulate exposures were used to estimate cumulative exposure during the study interval. Change in pulmonary function over the 7 years was found unrelated to the estimate of cumulative exposure during that interval. Exposure-response associations also were examined with respect to short-term peak exposures and incidence of five symptoms of acute respiratory irritation. Hourly measures of health outcome and continuous measures of particulate exposure were made on each subject throughout the day. Whenever a subject reported one of the irritant symptoms, a symptom intensity score was also recorded along with the approximate time of onset. The findings indicated that exposure-response relationships were present for each of the specific symptoms at several symptom intensity levels. The associations were present when exposure was estimated by both day-long and short-term (15-min) time-weighted average exposures. Associations persisted after taking account of smoking, age, and the presence of a common cold. No significant difference in response rate was found between workers exposed to different types of sodium borate dusts. PMID:7889871

  7. Measures of crowding in the emergency department: a systematic review.

    PubMed

    Hwang, Ula; McCarthy, Melissa L; Aronsky, Dominik; Asplin, Brent; Crane, Peter W; Craven, Catherine K; Epstein, Stephen K; Fee, Christopher; Handel, Daniel A; Pines, Jesse M; Rathlev, Niels K; Schafermeyer, Robert W; Zwemer, Frank L; Bernstein, Steven L

    2011-05-01

    Despite consensus regarding the conceptual foundation of crowding, and increasing research on factors and outcomes associated with crowding, there is no criterion standard measure of crowding. The objective was to conduct a systematic review of crowding measures and compare them in conceptual foundation and validity. This was a systematic, comprehensive review of four medical and health care citation databases to identify studies related to crowding in the emergency department (ED). Publications that "describe the theory, development, implementation, evaluation, or any other aspect of a 'crowding measurement/definition' instrument (qualitative or quantitative)" were included. A "measurement/definition" instrument is anything that assigns a value to the phenomenon of crowding in the ED. Data collected from papers meeting inclusion criteria were: study design, objective, crowding measure, and evidence of validity. All measures were categorized into five measure types (clinician opinion, input factors, throughput factors, output factors, and multidimensional scales). All measures were then indexed to six validation criteria (clinician opinion, ambulance diversion, left without being seen (LWBS), times to care, forecasting or predictions of future crowding, and other). There were 2,660 papers identified by databases; 46 of these papers met inclusion criteria, were original research studies, and were abstracted by reviewers. A total of 71 unique crowding measures were identified. The least commonly used type of crowding measure was clinician opinion, and the most commonly used were numerical counts (number or percentage) of patients and process times associated with patient care. Many measures had moderate to good correlation with validation criteria. Time intervals and patient counts are emerging as the most promising tools for measuring flow and nonflow (i.e., crowding), respectively. Standardized definitions of time intervals (flow) and numerical counts (nonflow) will assist with validation of these metrics across multiple sites and clarify which options emerge as the metrics of choice in this "crowded" field of measures. © 2011 by the Society for Academic Emergency Medicine.

  8. Effect of hyperoxia during the rest periods of interval training on perceptual recovery and oxygen re-saturation time.

    PubMed

    Peeling, Peter; Andersson, Ramon

    2011-01-01

    The effect of hyperoxic gas supplementation on the recovery time of oxygen saturation levels (S(a)O(2)), and its effect on perceptual recovery were assessed. Seven national-level kayak athletes completed two laboratory-based ergometer sessions of 6 × 3-min maximal aerobic intervals, with 2 min recovery between repetitions. During each recovery period, athletes either inhaled a hyperoxic gas (99.5 ± 0.2 % F(I)O(2)) or were given no external supplementation (control). Mean power output, stroke rate, heart rate, and ratings of perceived exertion were collected during each interval repetition, and the intensity was matched between trials. During each 2-min recovery period, post-exercise haemoglobin saturation levels were measured via pulse oximetry (S(p)O(2)), and the time taken for the S(p)O(2) to return to pre-exercise values was recorded. Subsequently, a rating of perceived recovery quality was collected. There were no differences in the levels of post-exercise de-saturation between the hyperoxic and control trials (P < 0.05), although the recovery time of S(p)O(2) was significantly faster in the hyperoxic trial (P < 0.05). There was no influence of oxygen supplementation on the athletes' perception of recovery quality. Hyperoxic gas supplementation during the recovery periods between high-intensity intervals substantially improves the recovery time of S(p)O(2) with no likely influence on recovery perception.

  9. Evaluation of the Finis Swimsense® and the Garmin Swim™ activity monitors for swimming performance and stroke kinematics analysis

    PubMed Central

    Mooney, Robert; Corley, Gavin; Godfrey, Alan; Osborough, Conor; ÓLaighin, Gearóid

    2017-01-01

    Aims The study aims were to evaluate the validity of two commercially available swimming activity monitors for quantifying temporal and kinematic swimming variables. Methods Ten national level swimmers (5 male, 5 female; 15.3±1.3years; 164.8±12.9cm; 62.4±11.1kg; 425±66 FINA points) completed a set protocol comprising 1,500m of swimming involving all four competitive swimming strokes. Swimmers wore the Finis Swimsense and the Garmin Swim activity monitors throughout. The devices automatically identified stroke type, swim distance, lap time, stroke count, stroke rate, stroke length and average speed. Video recordings were also obtained and used as a criterion measure to evaluate performance. Results A significant positive correlation was found between the monitors and video for the identification of each of the four swim strokes (Garmin: X2 (3) = 31.292, p<0.05; Finis:X2 (3) = 33.004, p<0.05). No significant differences were found for swim distance measurements. Swimming laps performed in the middle of a swimming interval showed no significant difference from the criterion (Garmin: bias -0.065, 95% confidence intervals -3.828–6.920; Finis bias -0.02, 95% confidence intervals -3.095–3.142). However laps performed at the beginning and end of an interval were not as accurately timed. Additionally, a statistical difference was found for stroke count measurements in all but two occasions (p<0.05). These differences affect the accuracy of stroke rate, stroke length and average speed scores reported by the monitors, as all of these are derived from lap times and stroke counts. Conclusions Both monitors were found to operate with a relatively similar performance level and appear suited for recreational use. However, issues with feature detection accuracy may be related to individual variances in stroke technique. It is reasonable to expect that this level of error would increase when the devices are used by recreational swimmers rather than elite swimmers. Further development to improve accuracy of feature detection algorithms, specifically for lap time and stroke count, would also increase their suitability within competitive settings. PMID:28178301

  10. Evaluation of the Finis Swimsense® and the Garmin Swim™ activity monitors for swimming performance and stroke kinematics analysis.

    PubMed

    Mooney, Robert; Quinlan, Leo R; Corley, Gavin; Godfrey, Alan; Osborough, Conor; ÓLaighin, Gearóid

    2017-01-01

    The study aims were to evaluate the validity of two commercially available swimming activity monitors for quantifying temporal and kinematic swimming variables. Ten national level swimmers (5 male, 5 female; 15.3±1.3years; 164.8±12.9cm; 62.4±11.1kg; 425±66 FINA points) completed a set protocol comprising 1,500m of swimming involving all four competitive swimming strokes. Swimmers wore the Finis Swimsense and the Garmin Swim activity monitors throughout. The devices automatically identified stroke type, swim distance, lap time, stroke count, stroke rate, stroke length and average speed. Video recordings were also obtained and used as a criterion measure to evaluate performance. A significant positive correlation was found between the monitors and video for the identification of each of the four swim strokes (Garmin: X2 (3) = 31.292, p<0.05; Finis:X2 (3) = 33.004, p<0.05). No significant differences were found for swim distance measurements. Swimming laps performed in the middle of a swimming interval showed no significant difference from the criterion (Garmin: bias -0.065, 95% confidence intervals -3.828-6.920; Finis bias -0.02, 95% confidence intervals -3.095-3.142). However laps performed at the beginning and end of an interval were not as accurately timed. Additionally, a statistical difference was found for stroke count measurements in all but two occasions (p<0.05). These differences affect the accuracy of stroke rate, stroke length and average speed scores reported by the monitors, as all of these are derived from lap times and stroke counts. Both monitors were found to operate with a relatively similar performance level and appear suited for recreational use. However, issues with feature detection accuracy may be related to individual variances in stroke technique. It is reasonable to expect that this level of error would increase when the devices are used by recreational swimmers rather than elite swimmers. Further development to improve accuracy of feature detection algorithms, specifically for lap time and stroke count, would also increase their suitability within competitive settings.

  11. A Further Assessment of Momentary Time-Sampling across Extended Interval Lengths

    ERIC Educational Resources Information Center

    Alvero, Alicia M.; Rappaport, Eva; Taylor, Matthew A.

    2011-01-01

    The current study compared the estimation of momentary time-sampling (MTS) to actual safety performance of three ergonomic responses: back, shoulder, and feet. Actual safety performance was established for the five participants by measuring the target responses with a continuous procedure. MTS 90, 105, 120, 135, 150, 165, 180, 195, 210, 240, and…

  12. Effects of Improvements in Interval Timing on the Mathematics Achievement of Elementary School Students

    ERIC Educational Resources Information Center

    Taub, Gordon E.; McGrew, Kevin S.; Keith, Timothy Z.

    2015-01-01

    This article examines the effect of improvements in timing/rhythmicity on mathematics achievement. A total of 86 participants attending 1st through 4th grades completed pre- and posttest measures of mathematics achievement from the Woodcock-Johnson III Tests of Achievement. Students in the experimental group participated in a 4-week intervention…

  13. Measurement of "g" Using a Flashing LED

    ERIC Educational Resources Information Center

    Terzella, T.; Sundermier, J.; Sinacore, J.; Owen, C.; Takai, H.

    2008-01-01

    In one of the classic free-fall experiments, a small mass is attached to a strip of paper tape and both are allowed to fall through a spark timer, where sparks are generated at regular time intervals. Students analyze marks (dots) left on the tape by the timer, thereby generating distance-versus-time data, which they analyze to extract the…

  14. Overuse of short-interval bone densitometry: assessing rates of low-value care.

    PubMed

    Morden, N E; Schpero, W L; Zaha, R; Sequist, T D; Colla, C H

    2014-09-01

    We evaluated the prevalence and geographic variation of short-interval (repeated in under 2 years) dual-energy X-ray absorptiometry tests (DXAs) among Medicare beneficiaries. Short-interval DXA use varied across regions (coefficient of variation = 0.64), and unlike other DXAs, rates decreased with payment cuts. The American College of Rheumatology, through the Choosing Wisely initiative, identified measuring bone density more often than every 2 years as care "physicians and patients should question." We measured the prevalence and described the geographic variation of short-interval (repeated in under 2 years) DXAs among Medicare beneficiaries and estimated the cost of this testing and its responsiveness to payment change. Using 100 % Medicare claims data, 2006-2011, we identified DXAs and short-interval DXAs for female Medicare beneficiaries over age 66. We determined the population rate of DXAs and short-interval DXAs, as well as Medicare spending on short-interval DXAs, nationally and by hospital referral region (HRR). DXA use was stable 2008-2011 (12.4 to 11.5 DXAs per 100 women). DXA use varied across HRRs: in 2011, overall DXA use ranged from 6.3 to 23.0 per 100 women (coefficient of variation = 0.18), and short-interval DXAs ranged from 0.3 to 8.0 per 100 women (coefficient of variation = 0.64). Short-interval DXA use fluctuated substantially with payment changes; other DXAs did not. Short-interval DXAs, which represented 10.1 % of all DXAs, cost Medicare approximately US$16 million in 2011. One out of ten DXAs was administered in a time frame shorter than recommended and at a substantial cost to Medicare. DXA use varied across regions. Short-interval DXA use was responsive to reimbursement changes, suggesting carefully designed policy and payment reform may reduce this care identified by rheumatologists as low value.

  15. Is high-intensity interval training a time-efficient exercise strategy to improve health and fitness?

    PubMed

    Gillen, Jenna B; Gibala, Martin J

    2014-03-01

    Growing research suggests that high-intensity interval training (HIIT) is a time-efficient exercise strategy to improve cardiorespiratory and metabolic health. "All out" HIIT models such as Wingate-type exercise are particularly effective, but this type of training may not be safe, tolerable or practical for many individuals. Recent studies, however, have revealed the potential for other models of HIIT, which may be more feasible but are still time-efficient, to stimulate adaptations similar to more demanding low-volume HIIT models and high-volume endurance-type training. As little as 3 HIIT sessions per week, involving ≤10 min of intense exercise within a time commitment of ≤30 min per session, including warm-up, recovery between intervals and cool down, has been shown to improve aerobic capacity, skeletal muscle oxidative capacity, exercise tolerance and markers of disease risk after only a few weeks in both healthy individuals and people with cardiometabolic disorders. Additional research is warranted, as studies conducted have been relatively short-term, with a limited number of measurements performed on small groups of subjects. However, given that "lack of time" remains one of the most commonly cited barriers to regular exercise participation, low-volume HIIT is a time-efficient exercise strategy that warrants consideration by health practitioners and fitness professionals.

  16. The molecular mechanism of the termination of insect diapause, part 1: A timer protein, TIME-EA4, in the diapause eggs of the silkworm Bombyx mori is a metallo-glycoprotein.

    PubMed

    Isobe, Minoru; Kai, Hidenori; Kurahashi, Takuya; Suwan, Sathorn; Pitchayawasin-Thapphasaraphong, Suthasinee; Franz, Thomas; Tani, Naoki; Higashi, Kenichiro; Nishida, Hideo

    2006-10-01

    TIME-EA4 is an ATPase that measures time intervals, functioning as a diapause duration clock in diapause eggs of the silkworm, Bombyx mori. Characterization of the primary and higher structures of the TIME-EA4 would be desirable to clarify the mechanism by which the protein measures the time intervals. In our current studies, the whole sequence of TIME-EA4 has been established as that of a metallo-glycoprotein by combinational means involving peptide sequence analysis, nano-HPLC-ESI-Q-TOF-MS and MS/MS, and cDNA dictation. The amino acid sequence of TIME-EA4 showed 46-55 % homology with the reported proteins of the Cu,Zn-SOD (superoxide dismutase) family; in particular, the SOD active site (core domain) includes metal-binding amino acid ligands and a disulfide bond, and these structures are completely identical in Bombyx SOD, bovine SOD, and TIME-EA4 proteins. We found, however, that TIME-EA4 contains one more copper ion than other SODs, as was proven under neutral nondenaturing conditions. ESI mass spectrometry revealed that the timer function was not in the SOD core domain. In addition, TIME-EA4 has an attached sugar chain, which is indispensable to its functioning as a timer protein.

  17. A cloud masking algorithm for EARLINET lidar systems

    NASA Astrophysics Data System (ADS)

    Binietoglou, Ioannis; Baars, Holger; D'Amico, Giuseppe; Nicolae, Doina

    2015-04-01

    Cloud masking is an important first step in any aerosol lidar processing chain as most data processing algorithms can only be applied on cloud free observations. Up to now, the selection of a cloud-free time interval for data processing is typically performed manually, and this is one of the outstanding problems for automatic processing of lidar data in networks such as EARLINET. In this contribution we present initial developments of a cloud masking algorithm that permits the selection of the appropriate time intervals for lidar data processing based on uncalibrated lidar signals. The algorithm is based on a signal normalization procedure using the range of observed values of lidar returns, designed to work with different lidar systems with minimal user input. This normalization procedure can be applied to measurement periods of only few hours, even if no suitable cloud-free interval exists, and thus can be used even when only a short period of lidar measurements is available. Clouds are detected based on a combination of criteria including the magnitude of the normalized lidar signal and time-space edge detection performed using the Sobel operator. In this way the algorithm avoids misclassification of strong aerosol layers as clouds. Cloud detection is performed using the highest available time and vertical resolution of the lidar signals, allowing the effective detection of low-level clouds (e.g. cumulus humilis). Special attention is given to suppress false cloud detection due to signal noise that can affect the algorithm's performance, especially during day-time. In this contribution we present the details of algorithm, the effect of lidar characteristics (space-time resolution, available wavelengths, signal-to-noise ratio) to detection performance, and highlight the current strengths and limitations of the algorithm using lidar scenes from different lidar systems in different locations across Europe.

  18. IEEE-1588(Trademark) Standard for a Precision Clock Synchronization Protocol for Networked Measurement and Control Systems

    DTIC Science & Technology

    2002-12-01

    34th Annual Precise Time and Time Interval (PTTI) Meeting 243 IEEE-1588™ STANDARD FOR A PRECISION CLOCK SYNCHRONIZATION PROTOCOL FOR... synchronization . 2. Cyclic-systems. In cyclic-systems, timing is periodic and is usually defined by the characteristics of a cyclic network or bus...incommensurate, timing schedules for each device are easily implemented. In addition, synchronization accuracy depends on the accuracy of the common

  19. Recognition of student names past: a longitudinal study with N = 1.

    PubMed

    Huang, I N

    1997-01-01

    Recognition of names of former students taught at different times by a middle-aged college professor was tested, to investigate recognition memory over a time span ranging from 6 months to 26.5 years. The relationship between the d', a measure of strength of memory, and the retention interval can be best described by a logarithmic function characterized by a rapid initial drop followed by a slow forgetting rate. The correct responses (hits and rejections) had higher confidence and shorter response time than did the incorrect responses (false alarms and misses). The results show that an ecologically realistic longitudinal study with N = 1 can provide a valuable means in the study of human memory with very long retention intervals, which have not yet been investigated in the laboratory.

  20. Evidence for impulsivity in the Spontaneously Hypertensive Rat drawn from complementary response-withholding tasks

    PubMed Central

    Sanabria, Federico; Killeen, Peter R

    2008-01-01

    Background The inability to inhibit reinforced responses is a defining feature of ADHD associated with impulsivity. The Spontaneously Hypertensive Rat (SHR) has been extolled as an animal model of ADHD, but there is no clear experimental evidence of inhibition deficits in SHR. Attempts to demonstrate these deficits may have suffered from methodological and analytical limitations. Methods We provide a rationale for using two complementary response-withholding tasks to doubly dissociate impulsivity from motivational and motor processes. In the lever-holding task (LHT), continual lever depression was required for a minimum interval. Under a differential reinforcement of low rates schedule (DRL), a minimum interval was required between lever presses. Both tasks were studied using SHR and two normotensive control strains, Wistar-Kyoto (WKY) and Long Evans (LE), over an overlapping range of intervals (1 – 5 s for LHT and 5 – 60 s for DRL). Lever-holding and DRL performance was characterized as the output of a mixture of two processes, timing and iterative random responding; we call this account of response inhibition the Temporal Regulation (TR) model. In the context of TR, impulsivity was defined as a bias toward premature termination of the timed intervals. Results The TR model provided an accurate description of LHT and DRL performance. On the basis of TR parameter estimates, SHRs were more impulsive than LE rats across tasks and target times. WKY rats produced substantially shorter timed responses in the lever-holding task than in DRL, suggesting a motivational or motor deficit. The precision of timing by SHR, as measured by the variance of their timed intervals, was excellent, flouting expectations from ADHD research. Conclusion This research validates the TR model of response inhibition and supports SHR as an animal model of ADHD-related impulsivity. It indicates, however, that SHR's impulse-control deficit is not caused by imprecise timing. The use of ad hoc impulsivity metrics and of WKY as control strain for SHR impulsivity are called into question. PMID:18261220

  1. A flexible model for multivariate interval-censored survival times with complex correlation structure.

    PubMed

    Falcaro, Milena; Pickles, Andrew

    2007-02-10

    We focus on the analysis of multivariate survival times with highly structured interdependency and subject to interval censoring. Such data are common in developmental genetics and genetic epidemiology. We propose a flexible mixed probit model that deals naturally with complex but uninformative censoring. The recorded ages of onset are treated as possibly censored ordinal outcomes with the interval censoring mechanism seen as arising from a coarsened measurement of a continuous variable observed as falling between subject-specific thresholds. This bypasses the requirement for the failure times to be observed as falling into non-overlapping intervals. The assumption of a normal age-of-onset distribution of the standard probit model is relaxed by embedding within it a multivariate Box-Cox transformation whose parameters are jointly estimated with the other parameters of the model. Complex decompositions of the underlying multivariate normal covariance matrix of the transformed ages of onset become possible. The new methodology is here applied to a multivariate study of the ages of first use of tobacco and first consumption of alcohol without parental permission in twins. The proposed model allows estimation of the genetic and environmental effects that are shared by both of these risk behaviours as well as those that are specific. 2006 John Wiley & Sons, Ltd.

  2. Interval versions of statistical techniques with applications to environmental analysis, bioinformatics, and privacy in statistical databases

    NASA Astrophysics Data System (ADS)

    Kreinovich, Vladik; Longpre, Luc; Starks, Scott A.; Xiang, Gang; Beck, Jan; Kandathi, Raj; Nayak, Asis; Ferson, Scott; Hajagos, Janos

    2007-02-01

    In many areas of science and engineering, it is desirable to estimate statistical characteristics (mean, variance, covariance, etc.) under interval uncertainty. For example, we may want to use the measured values x(t) of a pollution level in a lake at different moments of time to estimate the average pollution level; however, we do not know the exact values x(t)--e.g., if one of the measurement results is 0, this simply means that the actual (unknown) value of x(t) can be anywhere between 0 and the detection limit (DL). We must, therefore, modify the existing statistical algorithms to process such interval data. Such a modification is also necessary to process data from statistical databases, where, in order to maintain privacy, we only keep interval ranges instead of the actual numeric data (e.g., a salary range instead of the actual salary). Most resulting computational problems are NP-hard--which means, crudely speaking, that in general, no computationally efficient algorithm can solve all particular cases of the corresponding problem. In this paper, we overview practical situations in which computationally efficient algorithms exist: e.g., situations when measurements are very accurate, or when all the measurements are done with one (or few) instruments. As a case study, we consider a practical problem from bioinformatics: to discover the genetic difference between the cancer cells and the healthy cells, we must process the measurements results and find the concentrations c and h of a given gene in cancer and in healthy cells. This is a particular case of a general situation in which, to estimate states or parameters which are not directly accessible by measurements, we must solve a system of equations in which coefficients are only known with interval uncertainty. We show that in general, this problem is NP-hard, and we describe new efficient algorithms for solving this problem in practically important situations.

  3. Nonlinear effects in the time measurement device based on surface acoustic wave filter excitation.

    PubMed

    Prochazka, Ivan; Panek, Petr

    2009-07-01

    A transversal surface acoustic wave filter has been used as a time interpolator in a time interval measurement device. We are presenting the experiments and results of an analysis of the nonlinear effects in such a time interpolator. The analysis shows that the nonlinear distortion in the time interpolator circuits causes a deterministic measurement error which can be understood as the time interpolation nonlinearity. The dependence of this error on time of the measured events can be expressed as a sparse Fourier series thus it usually oscillates very quickly in comparison to the clock period. The theoretical model is in good agreement with experiments carried out on an experimental two-channel timing system. Using highly linear amplifiers in the time interpolator and adjusting the filter excitation level to the optimum, we have achieved the interpolation nonlinearity below 0.2 ps. The overall single-shot precision of the experimental timing device is 0.9 ps rms in each channel.

  4. Life-Space Assessment questionnaire: Novel measurement properties for Brazilian community-dwelling older adults.

    PubMed

    Simões, Maria do Socorro Mp; Garcia, Isabel Ff; Costa, Lucíola da Cm; Lunardi, Adriana C

    2018-05-01

    The Life-Space Assessment (LSA) assesses mobility from the spaces that older adults go, and how often and how independent they move. Despite its increased use, LSA measurement properties remain unclear. The aim of the present study was to analyze the content validity, reliability, construct validity and interpretability of the LSA for Brazilian community-dwelling older adults. In this clinimetric study we analyzed the measurement properties (content validity, reliability, construct validity and interpretability) of the LSA administered to 80 Brazilian community-dwelling older adults. Reliability was analyzed by Cronbach's alpha (internal consistency), intraclass correlation coefficients and 95% confidence interval (reproducibility), and standard error of measurement (measurement error). Construct validity was analyzed by Pearson's correlations between the LSA and accelerometry (time in inactivity and moderate-to-vigorous activities), and interpretability was analyzed by determination of the minimal detectable change, and floor and ceiling effects. The LSA met the criteria for content validity. The Cronbach's alpha was 0.92, intraclass correlation coefficient was 0.97 (95% confidence interval 0.95-0.98) and standard error of measurement was 4.12. The LSA showed convergence with accelerometry (negative correlation with time in inactivity and positive correlation with time in moderate to vigorous activities), the minimal detectable change was 0.36 and we observed no floor or ceiling effects. The LSA showed adequate reliability, validity and interpretability for life-space mobility assessment of Brazilian community-dwelling older adults. Geriatr Gerontol Int 2018; 18: 783-789. © 2018 Japan Geriatrics Society.

  5. Timescale- and Sensory Modality-Dependency of the Central Tendency of Time Perception.

    PubMed

    Murai, Yuki; Yotsumoto, Yuko

    2016-01-01

    When individuals are asked to reproduce intervals of stimuli that are intermixedly presented at various times, longer intervals are often underestimated and shorter intervals overestimated. This phenomenon may be attributed to the central tendency of time perception, and suggests that our brain optimally encodes a stimulus interval based on current stimulus input and prior knowledge of the distribution of stimulus intervals. Two distinct systems are thought to be recruited in the perception of sub- and supra-second intervals. Sub-second timing is subject to local sensory processing, whereas supra-second timing depends on more centralized mechanisms. To clarify the factors that influence time perception, the present study investigated how both sensory modality and timescale affect the central tendency. In Experiment 1, participants were asked to reproduce sub- or supra-second intervals, defined by visual or auditory stimuli. In the sub-second range, the magnitude of the central tendency was significantly larger for visual intervals compared to auditory intervals, while visual and auditory intervals exhibited a correlated and comparable central tendency in the supra-second range. In Experiment 2, the ability to discriminate sub-second intervals in the reproduction task was controlled across modalities by using an interval discrimination task. Even when the ability to discriminate intervals was controlled, visual intervals exhibited a larger central tendency than auditory intervals in the sub-second range. In addition, the magnitude of the central tendency for visual and auditory sub-second intervals was significantly correlated. These results suggest that a common modality-independent mechanism is responsible for the supra-second central tendency, and that both the modality-dependent and modality-independent components of the timing system contribute to the central tendency in the sub-second range.

  6. Multiscale analysis of heart rate dynamics: entropy and time irreversibility measures.

    PubMed

    Costa, Madalena D; Peng, Chung-Kang; Goldberger, Ary L

    2008-06-01

    Cardiovascular signals are largely analyzed using traditional time and frequency domain measures. However, such measures fail to account for important properties related to multiscale organization and non-equilibrium dynamics. The complementary role of conventional signal analysis methods and emerging multiscale techniques, is, therefore, an important frontier area of investigation. The key finding of this presentation is that two recently developed multiscale computational tools--multiscale entropy and multiscale time irreversibility--are able to extract information from cardiac interbeat interval time series not contained in traditional methods based on mean, variance or Fourier spectrum (two-point correlation) techniques. These new methods, with careful attention to their limitations, may be useful in diagnostics, risk stratification and detection of toxicity of cardiac drugs.

  7. Multiscale Analysis of Heart Rate Dynamics: Entropy and Time Irreversibility Measures

    PubMed Central

    Peng, Chung-Kang; Goldberger, Ary L.

    2016-01-01

    Cardiovascular signals are largely analyzed using traditional time and frequency domain measures. However, such measures fail to account for important properties related to multiscale organization and nonequilibrium dynamics. The complementary role of conventional signal analysis methods and emerging multiscale techniques, is, therefore, an important frontier area of investigation. The key finding of this presentation is that two recently developed multiscale computational tools— multiscale entropy and multiscale time irreversibility—are able to extract information from cardiac interbeat interval time series not contained in traditional methods based on mean, variance or Fourier spectrum (two-point correlation) techniques. These new methods, with careful attention to their limitations, may be useful in diagnostics, risk stratification and detection of toxicity of cardiac drugs. PMID:18172763

  8. Reference intervals and longitudinal changes in copeptin and MR-proADM concentrations during pregnancy.

    PubMed

    Joosen, Annemiek M C P; van der Linden, Ivon J M; Schrauwen, Lianne; Theeuwes, Alisia; de Groot, Monique J M; Ermens, Antonius A M

    2017-11-27

    Vasopressin and adrenomedullin and their stable by-products copeptin and midregional part of proadrenomedullin (MR-proADM) are promising biomarkers for the development of preeclampsia. However, clinical use is hampered by the lack of trimester-specific reference intervals. We therefore estimated reference intervals for copeptin and MR-proADM in disease-free Dutch women throughout pregnancy. Apparently healthy low risk pregnant women were recruited. Exclusion criteria included current or past history of endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, hemolysis elevated liver enzymes and low platelets, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded from analyses. Blood samples were collected at 9-13 weeks (n=98), 27-29 weeks (n=94) and 36-39 weeks (n=91) of gestation and at 4-13 weeks post-partum (PP) (n=89). Sixty-two women had complete data during pregnancy and PP. All analyses were performed on a Kryptor compact plus. Copeptin increases during pregnancy, but 97.5th percentiles remain below the non-pregnant upper reference limit (URL) provided by the manufacturer. MR-proADM concentrations increase as well during pregnancy. In trimesters 2 and 3 the 97.5th percentiles are over three times the non-pregnant URL provided by the manufacturer. Trimester- and assay-specific reference intervals for copeptin and MR-proADM should be used. In addition, consecutive measurements and the time frame between measurements should be considered as the differences seen with or in advance of preeclampsia can be expected to be relatively small compared to the reference intervals.

  9. Mechanical alterations during interval-training treadmill runs in high-level male team-sport players.

    PubMed

    Girard, Olivier; Brocherie, Franck; Morin, Jean-Benoit; Millet, Grégoire P

    2017-01-01

    To examine mechanical alterations during interval-training treadmill runs in high-level team-sport players. Within-participants repeated measures. Twenty high-level male field-hockey players performed six 30-s runs at 5.53±0.19ms -1 corresponding to 115% of their velocity associated with maximal oxygen uptake (vVO 2max ) with 30-s passive recovery on an instrumented treadmill. Continuous measurement of running kinetics/kinematics and spring-mass characteristics were performed and values were subsequently averaged over 20s (8th-28ths) for comparison. Contact time (+1.1±4.3%; p=0.044), aerial time (+4.1±5.3%; p=0.001), step length (+2.4±2.2%; p<0.001) along with mean loading rates (+7.1±10.6%; p=0.026) increased from the first to the last interval, whereas step frequency (-2.3±2.1%; p<0.001) decreased. Both centre of mass vertical displacement (+3.0±6.0%; p<0.001) and leg compression (+2.8±9.7%; p=0.036), but not peak vertical forces (0.0±4.1%; p=0.761), increased with fatigue. Vertical stiffness decreased (-2.8±6.9%; p=0.012), whereas leg stiffness did not change across intervals (p=0.149). During interval-training treadmill runs, high-level team-sport players modified their mechanical behaviour towards lower vertical stiffness while preserving a constant leg stiffness. Maintenance of running velocity induced longer step lengths and decreased step frequencies that were also accompanied by increased impact loading rates. These mechanical alterations occurred early during the set. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. The effect of short-duration sprint interval exercise on plasma postprandial triacylglycerol levels in young men.

    PubMed

    Allen, Edward; Gray, Partick; Kollias-Pearson, Angeliki; Oag, Erlend; Pratt, Katrina; Henderson, Jennifer; Gray, Stuart Robert

    2014-01-01

    It is well established that regular exercise can reduce the risk of cardiovascular disease, although the most time-efficient exercise protocol to confer benefits has yet to be established. The aim of the current study was to determine the effects of short-duration sprint interval exercise on postprandial triacylglycerol. Fifteen healthy male participants completed two 2 day trials. On day 1, participants rested (control) or carried out twenty 6 s sprints, interspersed with 24 s recovery (sprint interval exercise--14 min for total exercise session). On day 2, participants consumed a high-fat meal for breakfast with blood samples collected at baseline, 2 h and 4 h. Gas exchange was also measured at these time points. On day 2 of control and sprint interval exercise trials, there were no differences (P < 0.05) between trials in plasma glucose, triacylglycerol, insulin or respiratory exchange ratio (RER). The area under the curve for plasma triacylglycerol was 7.67 ± 2.37 mmol · l(-1) x 4 h(-1) in the control trial and 7.26 ± 2.49 mmol · l(-1) x 4 h(-1) in the sprint interval exercise trial. Although the sprint exercise protocol employed had no significant effect on postprandial triacylglycerol, there was a clear variability in responses that warrants further investigation.

  11. A Prospective Observational Comparison Between Arm and Wrist Blood Pressure During Scheduled Cesarean Delivery.

    PubMed

    Sebbag, Ilana; Massey, Simon R; Albert, Arianne Y K; Dube, Alison; Gunka, Vit; Douglas, M Joanne

    2015-09-01

    Shivering is common during cesarean delivery (CD) under neuraxial anesthesia and may disrupt the measurement of noninvasive blood pressure (BP). BP measured at the wrist may be less affected by shivering. There have been no studies comparing trends in BP measured on the upper arm and wrist. We hypothesized that wrist systolic blood pressure (sBP) would accurately trend with upper arm sBP measurements (agree within a limit of ±10%) in parturients undergoing elective CD under spinal anesthesia or combined spinal-epidural anesthesia. After initiation of spinal anesthesia, BP measurements were obtained simultaneously from the upper arm and wrist on opposite arms. The interval between measurements was 1 to 2 minutes, and data were collected for 20 minutes or until delivery. The primary outcome was agreement in dynamic changes in sBP measurements between the upper arm and the wrist. Bland-Altman plots indicating the levels of agreement between the methods were drawn for baseline measurements, over multiple measurements, and over multiple measurements on percentage change from baseline. Forty-nine patients were recruited and completed the study. The wrist sBP tended to overestimate the upper sBP for both baseline data (sBP bias = 13.4 mm Hg; 95% confidence interval = +10.4 to +16.4 mm Hg) and data obtained over multiple measurements (sBP bias = 12.8 mm Hg; 95% confidence interval = +9.3 to +16.3 mm Hg). For change in sBP from baseline over multiple measurements, the mean difference between the wrist and the arm sBP was -0.2 percentage points (99% limits of agreement -25 to +25 percentage points). The wrist measurement overestimated the reading relative to the upper arm measurement for multiple measurements over time. However, when the time series for each subject was examined for percentage change from baseline, the 2 methods mirrored each other in most cases. Nevertheless, our hypothesis was rejected as the limits of agreement were higher than ±10%. This finding suggests that wrist BP may not be an accurate method of detecting hypotension or hypertension during spinal or combined spinal-epidural anesthesia for CD.

  12. Electrocardiographic findings in chronic hemodialysis patients.

    PubMed

    Bignotto, Luís Henrique; Kallás, Marina Esteves; Djouki, Rafael Jorge Teixeira; Sassaki, Marcela Mayume; Voss, Guilherme Ota; Soto, Cristina Lopez; Frattini, Fernando; Medeiros, Flávia Silva Reis

    2012-01-01

    Cardiovascular disease is the leading cause of mortality among patients on dialysis. When considering all causes of death, about 30% are classified as cardiac arrest, death of unknown cause or cardiac arrhythmia. The increasing time of ventricular depolarization and repolarization, measured non-invasively by measuring the QT interval on the electrocardiogram at rest, has emerged as a predictor of complex ventricular arrhythmias, a major cause of sudden cardiac death. To determine the electrocardiographic alterations present in hemodialysis (HD) patients, measuring the QT interval and its relationship with clinical and laboratory variables. Patients above 18 years on dialysis were approached to participate in the study and, after consent, were submitted to the examination of 12-lead electrocardiogram. Clinical data were reviewed to assess the presence of comorbidities, as well as anthropometric and blood pressure measures. Blood samples were collected to determinate hemoglobin and serum levels of calcium, phosphorus and potassium. One hundred and seventy nine patients were included in the study. The majority of the patients were male (64.8%) and white (54.7%); the average age was 58.5 ± 14.7 years old. About 50% of all patients had, at least, one electrical conduction disturb. About 50% of all patients had QTc prolongation and experienced a significant increase in the frequency of Left Ventricular Hypertrophy (LVH), changes of the cardiac rhythm and bundle branch blocks, and a lower body mass index (BMI), when compared with normal QTc interval patients. Patients with chronic kidney disease (CKD) on hemodialysis had high frequency of abnormal electrocardiographic findings, including a high prevalence of patients with prolonged QTc interval. This study also found a significant association between prolonged QTc interval and the presence of Diabetes and lower values of BMI.

  13. Measuring the marginal cost of congestion.

    DOT National Transportation Integrated Search

    2008-12-01

    This study attempted to estimate the effect of additional vehicles joining the traffic stream when it is near : capacity. The study used data from highways I-35, I-45 in Texas and I-80 in California aggregated at different time : intervals. Various m...

  14. Sampling and Control Circuit Board for an Inertial Measurement Unit

    NASA Technical Reports Server (NTRS)

    Chelmins, David T (Inventor); Sands, Obed (Inventor); Powis, Richard T., Jr. (Inventor)

    2016-01-01

    A circuit board that serves as a control and sampling interface to an inertial measurement unit ("IMU") is provided. The circuit board is also configured to interface with a local oscillator and an external trigger pulse. The circuit board is further configured to receive the external trigger pulse from an external source that time aligns the local oscillator and initiates sampling of the inertial measurement device for data at precise time intervals based on pulses from the local oscillator. The sampled data may be synchronized by the circuit board with other sensors of a navigation system via the trigger pulse.

  15. Tailoring magnetic domains in Gd-Fe thin films

    NASA Astrophysics Data System (ADS)

    Talapatra, A.; Chelvane, J. Arout; Mohanty, J.

    2018-05-01

    This paper presents the global modification of magnetic domains and magnetic properties in amorphous Gd19Fe81 thin films with rapid thermal processing at two distinct temperatures (250oC and 450oC), and with different time intervals viz., 2, 5, 10 and 20 minutes. 100 nm thick as-prepared films display nano-scale meandering stripe domains with high magnetic phase contrast which is the signature of perpendicular magnetic anisotropy. The films processed at 250oC for various time intervals show successive reduction in magnetic phase contrast and domain size. The domain pattern completely disappeared, and topography dominated mixed magnetic phase has been obtained for the films processed at 450oC for time intervals greater than 2 minutes. The magnetization measurements indicate the reduction in perpendicular magnetic anisotropy with increase in saturation magnetization for all the rapid thermal processed films. The experimental outputs have been used to simulate the domain pattern. Reduction in uniaxial anisotropy along with the increase in saturation magnetization successfully explain the experimental trend of decrease in domain size and magnetic contrast.

  16. Development of two-framing camera with large format and ultrahigh speed

    NASA Astrophysics Data System (ADS)

    Jiang, Xiaoguo; Wang, Yuan; Wang, Yi

    2012-10-01

    High-speed imaging facility is important and necessary for the formation of time-resolved measurement system with multi-framing capability. The framing camera which satisfies the demands of both high speed and large format needs to be specially developed in the ultrahigh speed research field. A two-framing camera system with high sensitivity and time-resolution has been developed and used for the diagnosis of electron beam parameters of Dragon-I linear induction accelerator (LIA). The camera system, which adopts the principle of light beam splitting in the image space behind the lens with long focus length, mainly consists of lens-coupled gated image intensifier, CCD camera and high-speed shutter trigger device based on the programmable integrated circuit. The fastest gating time is about 3 ns, and the interval time between the two frames can be adjusted discretely at the step of 0.5 ns. Both the gating time and the interval time can be tuned to the maximum value of about 1 s independently. Two images with the size of 1024×1024 for each can be captured simultaneously in our developed camera. Besides, this camera system possesses a good linearity, uniform spatial response and an equivalent background illumination as low as 5 electrons/pix/sec, which fully meets the measurement requirements of Dragon-I LIA.

  17. Accelerometer Data Analysis and Presentation Techniques

    NASA Technical Reports Server (NTRS)

    Rogers, Melissa J. B.; Hrovat, Kenneth; McPherson, Kevin; Moskowitz, Milton E.; Reckart, Timothy

    1997-01-01

    The NASA Lewis Research Center's Principal Investigator Microgravity Services project analyzes Orbital Acceleration Research Experiment and Space Acceleration Measurement System data for principal investigators of microgravity experiments. Principal investigators need a thorough understanding of data analysis techniques so that they can request appropriate analyses to best interpret accelerometer data. Accelerometer data sampling and filtering is introduced along with the related topics of resolution and aliasing. Specific information about the Orbital Acceleration Research Experiment and Space Acceleration Measurement System data sampling and filtering is given. Time domain data analysis techniques are discussed and example environment interpretations are made using plots of acceleration versus time, interval average acceleration versus time, interval root-mean-square acceleration versus time, trimmean acceleration versus time, quasi-steady three dimensional histograms, and prediction of quasi-steady levels at different locations. An introduction to Fourier transform theory and windowing is provided along with specific analysis techniques and data interpretations. The frequency domain analyses discussed are power spectral density versus frequency, cumulative root-mean-square acceleration versus frequency, root-mean-square acceleration versus frequency, one-third octave band root-mean-square acceleration versus frequency, and power spectral density versus frequency versus time (spectrogram). Instructions for accessing NASA Lewis Research Center accelerometer data and related information using the internet are provided.

  18. Evaluation of Learning Associated with Multiple Exposures to Computerized Dynamic Posturography

    NASA Technical Reports Server (NTRS)

    Dean, S. Lance; Paloski, William H.; Taylor, Laura C.; Vanya, Robert D.; Feiveson, Alan H.; Wood, Scott J.

    2009-01-01

    Computerized dynamic posturography has been used to quantitatively assess the time course of functional sensorimotor recovery after exposure to spaceflight or to groundbased analogs such as head-down bed rest. An assessment of balance recovery may be confounded as subjects develop new strategies through repeated exposures to test paradigms. The purpose of this control study was to characterize the learning effects of sensory organization and motor control tests across multiple sessions. METHODS: Twenty-eight healthy subjects were tested over four sessions. To examine the effects of between-session interval, subjects were assigned to one of four groups in which the interval between the 1 st and 2nd sessions was 7 (+/- 1) days, 14 (+/-1) days, 28 (+/-2) days, or 56 (+/-3) days. The interval between remaining sessions was 28 (+/-4) days. Peak-to-peak anterior-posterior sway was measured during standard Sensory Organization Tests (SOTs) using either fixed or unstable sway-referenced support with eyes open, eyes closed, or sway-referenced vision. Sway was also measured during modified SOTs using eyes-closed conditions with either static or dynamic head tilts. Postural recovery to unexpected support surface perturbations (translations or rotations) was measured during Motor Control Tests. The test order was block randomized across subjects. RESULTS: The learning effects varied with test condition. There were no measurable differences with a stable support surface. The more challenging conditions (unstable support surface with and without head tilts) led to greater differences and took more trials to stabilize. The effect of time interval between the first two sessions was negligible across conditions. Evidence suggested that learning carried across similar conditions (such as unstable support SOTs). DISCUSSION: Familiarization session and/or trials are recommended to minimize learning effects when characterizing functional recovery after exposure to altered sensory environments. The number of practice trials required depends on task difficulty and similarity across conditions. Learning statement: This presentation will review the learning effects of computerized d

  19. The 1983 tail-era series. Volume 1: ISEE 3 plasma

    NASA Technical Reports Server (NTRS)

    Fairfield, D. H.; Phillips, J. L.

    1991-01-01

    Observations from the ISEE 3 electron analyzer are presented in plots. Electrons were measured in 15 continuous energy levels between 8.5 and 1140 eV during individual 3-sec spacecraft spins. Times associated with each data point are the beginning time of the 3 sec data collection interval. Moments calculated from the measured distribution function are shown as density, temperature, velocity, and velocity azimuthal angle. Spacecraft ephemeris is shown at the bottom in GSE and GSM coordinates in units of Earth radii, with vertical ticks on the time axis corresponding to the printed positions.

  20. Operating manual for the RRL 8 channel data logger

    NASA Technical Reports Server (NTRS)

    Paluch, E. J.; Shelton, J. D.; Gardner, C. S.

    1979-01-01

    A data collection device which takes measurements from external sensors at user specified time intervals is described. Three sensor ports are dedicated to temperature, air pressure, and dew point. Five general purpose sensor ports are provided. The user specifies when the measurements are recorded as well as when the information is read or stored in a minicomputer or a paper tape.

  1. Is breast compression associated with breast cancer detection and other early performance measures in a population-based breast cancer screening program?

    PubMed

    Moshina, Nataliia; Sebuødegård, Sofie; Hofvind, Solveig

    2017-06-01

    We aimed to investigate early performance measures in a population-based breast cancer screening program stratified by compression force and pressure at the time of mammographic screening examination. Early performance measures included recall rate, rates of screen-detected and interval breast cancers, positive predictive value of recall (PPV), sensitivity, specificity, and histopathologic characteristics of screen-detected and interval breast cancers. Information on 261,641 mammographic examinations from 93,444 subsequently screened women was used for analyses. The study period was 2007-2015. Compression force and pressure were categorized using tertiles as low, medium, or high. χ 2 test, t tests, and test for trend were used to examine differences between early performance measures across categories of compression force and pressure. We applied generalized estimating equations to identify the odds ratios (OR) of screen-detected or interval breast cancer associated with compression force and pressure, adjusting for fibroglandular and/or breast volume and age. The recall rate decreased, while PPV and specificity increased with increasing compression force (p for trend <0.05 for all). The recall rate increased, while rate of screen-detected cancer, PPV, sensitivity, and specificity decreased with increasing compression pressure (p for trend <0.05 for all). High compression pressure was associated with higher odds of interval breast cancer compared with low compression pressure (1.89; 95% CI 1.43-2.48). High compression force and low compression pressure were associated with more favorable early performance measures in the screening program.

  2. Phase 1, randomized, parallel-group, double-blind, placebo-controlled trial to evaluate the effects of erenumab (AMG 334) and concomitant sumatriptan on blood pressure in healthy volunteers.

    PubMed

    de Hoon, Jan; Van Hecken, Anne; Vandermeulen, Corinne; Herbots, Marissa; Kubo, Yumi; Lee, Ed; Eisele, Osa; Vargas, Gabriel; Gabriel, Kristin

    2018-01-01

    Objectives The aim of this study was to assess the effects of concomitant administration of erenumab and sumatriptan on resting blood pressure, pharmacokinetics, safety, and tolerability in healthy subjects. Methods In this phase 1, parallel-group, one-way crossover, double-blind, placebo-controlled study, healthy adult subjects were randomized (1:2) to receive either intravenous placebo and subcutaneous sumatriptan 12 mg (i.e. two 6-mg injections separated by 1 hour) or intravenous erenumab 140 mg and subcutaneous sumatriptan 12 mg. Blood pressure was measured pre-dose and at prespecified times post-dose. The primary endpoint was individual time-weighted averages of mean arterial pressure, measured from 0 hours to 2.5 hours after the first dose of sumatriptan. Pharmacokinetic parameters for sumatriptan were evaluated by calculating geometric mean ratios (erenumab and sumatriptan/placebo and sumatriptan). Adverse events and anti-erenumab antibodies were also evaluated. Results A total of 34 subjects were randomized and included in the analysis. Least squares mean (standard error) time-weighted averages of mean arterial pressure were 87.4 (1.0) mmHg for the placebo and sumatriptan group and 87.4 (1.2) mmHg for the erenumab and sumatriptan group. Mean difference in mean arterial pressure between groups was -0.04 mmHg (90% confidence interval: -2.2, 2.1). Geometric mean ratio estimates for maximum plasma concentration of sumatriptan was 0.95 (90% confidence interval: 0.82, 1.09), area under the plasma concentration-time curve (AUC) from time 0 to 6 hours was 0.98 (90% confidence interval: 0.93, 1.03), and AUC from time 0 to infinity was 1.00 (90% confidence interval: 0.96, 1.05). No clinically relevant safety findings for co-administration of sumatriptan and erenumab were identified. Conclusion Co-administration of erenumab and sumatriptan had no additional effect on resting blood pressure or on pharmacokinetics of sumatriptan. ClinicalTrials.gov, NCT02741310.

  3. The third-stimulus temporal discrimination threshold: focusing on the temporal processing of sensory input within primary somatosensory cortex.

    PubMed

    Leodori, Giorgio; Formica, Alessandra; Zhu, Xiaoying; Conte, Antonella; Belvisi, Daniele; Cruccu, Giorgio; Hallett, Mark; Berardelli, Alfredo

    2017-10-01

    The somatosensory temporal discrimination threshold (STDT) has been used in recent years to investigate time processing of sensory information, but little is known about the physiological correlates of somatosensory temporal discrimination. The objective of this study was to investigate whether the time interval required to discriminate between two stimuli varies according to the number of stimuli in the task. We used the third-stimulus temporal discrimination threshold (ThirdDT), defined as the shortest time interval at which an individual distinguishes a third stimulus following a pair of stimuli delivered at the STDT. The STDT and ThirdDT were assessed in 31 healthy subjects. In a subgroup of 10 subjects, we evaluated the effects of the stimuli intensity on the ThirdDT. In a subgroup of 16 subjects, we evaluated the effects of S1 continuous theta-burst stimulation (S1-cTBS) on the STDT and ThirdDT. Results show that ThirdDT is shorter than STDT. We found a positive correlation between STDT and ThirdDT values. As long as the stimulus intensity was within the perceivable and painless range, it did not affect ThirdDT values. S1-cTBS significantly affected both STDT and ThirdDT, although the latter was affected to a greater extent and for a longer period of time. We conclude that the interval needed to discriminate between time-separated tactile stimuli is related to the number of stimuli used in the task. STDT and ThirdDT are encoded in S1, probably by a shared tactile temporal encoding mechanism whose performance rapidly changes during the perception process. ThirdDT is a new method to measure somatosensory temporal discrimination. NEW & NOTEWORTHY To investigate whether the time interval required to discriminate between stimuli varies according to changes in the stimulation pattern, we used the third-stimulus temporal discrimination threshold (ThirdDT). We found that the somatosensory temporal discrimination acuity varies according to the number of stimuli in the task. The ThirdDT is a new method to measure somatosensory temporal discrimination and a possible index of inhibitory activity at the S1 level. Copyright © 2017 the American Physiological Society.

  4. Heart rate dynamics before spontaneous onset of ventricular fibrillation in patients with healed myocardial infarcts

    NASA Technical Reports Server (NTRS)

    Makikallio, T. H.; Koistinen, J.; Jordaens, L.; Tulppo, M. P.; Wood, N.; Golosarsky, B.; Peng, C. K.; Goldberger, A. L.; Huikuri, H. V.

    1999-01-01

    The traditional methods of analyzing heart rate (HR) variability have failed to predict imminent ventricular fibrillation (VF). We sought to determine whether new methods of analyzing RR interval variability based on nonlinear dynamics and fractal analysis may help to detect subtle abnormalities in RR interval behavior before the onset of life-threatening arrhythmias. RR interval dynamics were analyzed from 24-hour Holter recordings of 15 patients who experienced VF during electrocardiographic recording. Thirty patients without spontaneous or inducible arrhythmia events served as a control group in this retrospective case control study. Conventional time- and frequency-domain measurements, the short-term fractal scaling exponent (alpha) obtained by detrended fluctuation analysis, and the slope (beta) of the power-law regression line (log power - log frequency, 10(-4)-10(-2) Hz) of RR interval dynamics were determined. The short-term correlation exponent alpha of RR intervals (0.64 +/- 0.19 vs 1.05 +/- 0.12; p <0.001) and the power-law slope beta (-1.63 +/- 0.28 vs -1.31 +/- 0.20, p <0.001) were lower in the patients before the onset of VF than in the control patients, but the SD and the low-frequency spectral components of RR intervals did not differ between the groups. The short-term scaling exponent performed better than any other measurement of HR variability in differentiating between the patients with VF and controls. Altered fractal correlation properties of HR behavior precede the spontaneous onset of VF. Dynamic analysis methods of analyzing RR intervals may help to identify abnormalities in HR behavior before VF.

  5. An investigation of a hypothermic to ischemic ratio in patients following out-of-hospital cardiac arrest presenting with a shockable rhythm.

    PubMed

    Sawyer, Kelly N; Kurz, Michael C; Elswick, R K

    2014-06-01

    Targeted temperature management (TTM) improves outcome after out-of-hospital cardiac arrest (OHCA). We hypothesized that there may be a significant relationship between the dose of hypothermia, the time to return of spontaneous circulation (ROSC), and survival to discharge. Retrospective pilot investigation on 99 consecutive OHCA patients with initial shockable rhythm, surviving to admission, and undergoing TTM between 2008 and 2011. Dose of hypothermia was defined as the sum of the induction interval (time to target temperature [from ROSC to 33°C]); the controlled hypothermia interval (from reaching 33°C until rewarming); and the rewarming interval (from 33°C to 37°C). Time to ROSC was measured from pulselessness or 911 call time to ROSC. The ratio between the two was termed the hypothermic to ischemic ratio. Purposeful variable selection for logistic regression modeling was used to assess the influence of the hypothermic/ischemic ratio on survival. Odds ratios (OR) were used to examine the effects of predictor variables on survival. Of 99 patients, eight were excluded for deviation from protocol, death during protocol, or missing data. From the univariate models, survivors were more likely to be younger, have a shorter time to ROSC, and have a larger hypothermic/ischemic ratio. Survivors also had a nonsignificant trend toward a longer time to target temperature. In multivariable modeling, the hypothermic/ischemic ratio was the most significant predictor for survival (OR 2.161 [95% confidence interval 1.371, 3.404]). In this pilot study, the hypothermic to ischemic ratio was significantly associated with survival to discharge for patients with an initial shockable rhythm. Further investigation of the relationship between the dose of hypothermia and time to ROSC for postresuscitation TTM is needed.

  6. Motor Timing Deficits in Sequential Movements in Parkinson Disease Are Related to Action Planning: A Motor Imagery Study

    PubMed Central

    Avanzino, Laura; Pelosin, Elisa; Martino, Davide; Abbruzzese, Giovanni

    2013-01-01

    Timing of sequential movements is altered in Parkinson disease (PD). Whether timing deficits in internally generated sequential movements in PD depends also on difficulties in motor planning, rather than merely on a defective ability to materially perform the planned movement is still undefined. To unveil this issue, we adopted a modified version of an established test for motor timing, i.e. the synchronization–continuation paradigm, by introducing a motor imagery task. Motor imagery is thought to involve mainly processes of movement preparation, with reduced involvement of end-stage movement execution-related processes. Fourteen patients with PD and twelve matched healthy volunteers were asked to tap in synchrony with a metronome cue (SYNC) and then, when the tone stopped, to keep tapping, trying to maintain the same rhythm (CONT-EXE) or to imagine tapping at the same rhythm, rather than actually performing it (CONT-MI). We tested both a sub-second and a supra-second inter-stimulus interval between the cues. Performance was recorded using a sensor-engineered glove and analyzed measuring the temporal error and the interval reproduction accuracy index. PD patients were less accurate than healthy subjects in the supra-second time reproduction task when performing both continuation tasks (CONT-MI and CONT-EXE), whereas no difference was detected in the synchronization task and on all tasks involving a sub-second interval. Our findings suggest that PD patients exhibit a selective deficit in motor timing for sequential movements that are separated by a supra-second interval and that this deficit may be explained by a defect of motor planning. Further, we propose that difficulties in motor planning are of a sufficient degree of severity in PD to affect also the motor performance in the supra-second time reproduction task. PMID:24086534

  7. A stretch/compress scheme for a high temporal resolution detector for the magnetic recoil spectrometer time (MRSt)

    DOE PAGES

    Hilsabeck, T. J.; Frenje, J. A.; Hares, J. D.; ...

    2016-08-02

    Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording.more » Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.« less

  8. A stretch/compress scheme for a high temporal resolution detector for the magnetic recoil spectrometer time (MRSt)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hilsabeck, T. J.; Frenje, J. A.; Hares, J. D.

    Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording.more » Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.« less

  9. Prefire identification for pulse-power systems

    DOEpatents

    Longmire, J.L.; Thuot, M.E.; Warren, D.S.

    1982-08-23

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  10. Prefire identification for pulse power systems

    DOEpatents

    Longmire, Jerry L.; Thuot, Michael E.; Warren, David S.

    1985-01-01

    Prefires in a high-power, high-frequency, multi-stage pulse generator are detected by a system having an EMI shielded pulse timing transmitter associated with and tailored to each stage of the pulse generator. Each pulse timing transmitter upon detection of a pulse triggers a laser diode to send an optical signal through a high frequency fiber optic cable to a pulse timing receiver which converts the optical signal to an electrical pulse. The electrical pulses from all pulse timing receivers are fed through an OR circuit to start a time interval measuring device and each electrical pulse is used to stop an individual channel in the measuring device thereby recording the firing sequence of the multi-stage pulse generator.

  11. Effectiveness of motor sequential learning according to practice schedules in healthy adults; distributed practice versus massed practice

    PubMed Central

    Kwon, Yong Hyun; Kwon, Jung Won; Lee, Myoung Hee

    2015-01-01

    [Purpose] The purpose of the current study was to compare the effectiveness of motor sequential learning according to two different types of practice schedules, distributed practice schedule (two 12-hour inter-trial intervals) and massed practice schedule (two 10-minute inter-trial intervals) using a serial reaction time (SRT) task. [Subjects and Methods] Thirty healthy subjects were recruited and then randomly and evenly assigned to either the distributed practice group or the massed practice group. All subjects performed three consecutive sessions of the SRT task following one of the two different types of practice schedules. Distributed practice was scheduled for two 12-hour inter-session intervals including sleeping time, whereas massed practice was administered for two 10-minute inter-session intervals. Response time (RT) and response accuracy (RA) were measured in at pre-test, mid-test, and post-test. [Results] For RT, univariate analysis demonstrated significant main effects in the within-group comparison of the three tests as well as the interaction effect of two groups × three tests, whereas the between-group comparison showed no significant effect. The results for RA showed no significant differences in neither the between-group comparison nor the interaction effect of two groups × three tests, whereas the within-group comparison of the three tests showed a significant main effect. [Conclusion] Distributed practice led to enhancement of motor skill acquisition at the first inter-session interval as well as at the second inter-interval the following day, compared to massed practice. Consequentially, the results of this study suggest that a distributed practice schedule can enhance the effectiveness of motor sequential learning in 1-day learning as well as for two days learning formats compared to massed practice. PMID:25931727

  12. Discrete- vs. Continuous-Time Modeling of Unequally Spaced Experience Sampling Method Data.

    PubMed

    de Haan-Rietdijk, Silvia; Voelkle, Manuel C; Keijsers, Loes; Hamaker, Ellen L

    2017-01-01

    The Experience Sampling Method is a common approach in psychological research for collecting intensive longitudinal data with high ecological validity. One characteristic of ESM data is that it is often unequally spaced, because the measurement intervals within a day are deliberately varied, and measurement continues over several days. This poses a problem for discrete-time (DT) modeling approaches, which are based on the assumption that all measurements are equally spaced. Nevertheless, DT approaches such as (vector) autoregressive modeling are often used to analyze ESM data, for instance in the context of affective dynamics research. There are equivalent continuous-time (CT) models, but they are more difficult to implement. In this paper we take a pragmatic approach and evaluate the practical relevance of the violated model assumption in DT AR(1) and VAR(1) models, for the N = 1 case. We use simulated data under an ESM measurement design to investigate the bias in the parameters of interest under four different model implementations, ranging from the true CT model that accounts for all the exact measurement times, to the crudest possible DT model implementation, where even the nighttime is treated as a regular interval. An analysis of empirical affect data illustrates how the differences between DT and CT modeling can play out in practice. We find that the size and the direction of the bias in DT (V)AR models for unequally spaced ESM data depend quite strongly on the true parameter in addition to data characteristics. Our recommendation is to use CT modeling whenever possible, especially now that new software implementations have become available.

  13. Discrete- vs. Continuous-Time Modeling of Unequally Spaced Experience Sampling Method Data

    PubMed Central

    de Haan-Rietdijk, Silvia; Voelkle, Manuel C.; Keijsers, Loes; Hamaker, Ellen L.

    2017-01-01

    The Experience Sampling Method is a common approach in psychological research for collecting intensive longitudinal data with high ecological validity. One characteristic of ESM data is that it is often unequally spaced, because the measurement intervals within a day are deliberately varied, and measurement continues over several days. This poses a problem for discrete-time (DT) modeling approaches, which are based on the assumption that all measurements are equally spaced. Nevertheless, DT approaches such as (vector) autoregressive modeling are often used to analyze ESM data, for instance in the context of affective dynamics research. There are equivalent continuous-time (CT) models, but they are more difficult to implement. In this paper we take a pragmatic approach and evaluate the practical relevance of the violated model assumption in DT AR(1) and VAR(1) models, for the N = 1 case. We use simulated data under an ESM measurement design to investigate the bias in the parameters of interest under four different model implementations, ranging from the true CT model that accounts for all the exact measurement times, to the crudest possible DT model implementation, where even the nighttime is treated as a regular interval. An analysis of empirical affect data illustrates how the differences between DT and CT modeling can play out in practice. We find that the size and the direction of the bias in DT (V)AR models for unequally spaced ESM data depend quite strongly on the true parameter in addition to data characteristics. Our recommendation is to use CT modeling whenever possible, especially now that new software implementations have become available. PMID:29104554

  14. Evidence for age-related changes to temporal attention and memory from the choice time production task

    PubMed Central

    Gooch, Cynthia M.; Stern, Yaakov; Rakitin, Brian C.

    2009-01-01

    The effect of aging on interval timing was examined using a choice time production task, which required participants to choose a key response based on the location of the stimulus, but to delay responding until after a learned time interval. Experiment 1 varied attentional demands of the response choice portion of the task by varying difficulty of stimulus-response mapping. Choice difficulty affected temporal accuracy equally in both age groups, but older participants’ response latencies were more variable under more difficult response choice conditions. Experiment 2 tested the contribution of long-term memory to differences in choice time production between age groups over 3 days of testing. Direction of errors in time production between the two age groups diverged over the 3 sessions, but variability did not differ. Results from each experiment separately show age-related changes to attention and memory in temporal processing using different measures and manipulations in the same task. PMID:19132578

  15. A Longitudinal Study of Complexity, Accuracy and Fluency Variation in Second Language Development

    ERIC Educational Resources Information Center

    Ferraris, Stefania

    2012-01-01

    This chapter presents the results of a study on interlanguage variation. The production of four L2 learners of Italian, tested four times at yearly intervals while engaged in four oral tasks, is compared to that of two native speakers, and analysed with quantitative CAF measures. Thus, time, task type, nativeness, as well as group vs. individual…

  16. The interval between cancer diagnosis among mothers and offspring in a population-based cohort.

    PubMed

    Paltiel, Ora; Friedlander, Yehiel; Deutsch, Lisa; Yanetz, Rebecca; Calderon-Margalit, Ronit; Tiram, Efrat; Hochner, Hagit; Barchana, Micha; Harlap, Susan; Manor, Orly

    2007-01-01

    Familial cancers may be due to shared genes or environment, or chance aggregation. We explored the possibility that ascertainment bias influences cancer detection in families, bearing upon the time interval between diagnosis of affected mothers and offspring. The Jerusalem Perinatal Study (JPS) comprises all mothers (n = 39,734) from Western Jerusalem who gave birth 1964 -1976 and their offspring (n = 88,829). After linking identification numbers with Israel's Cancer Registry we measured the absolute time interval between initial cancer diagnoses in affected mother-offspring pairs. We tested the probability of obtaining intervals as short as those observed by chance alone, using a permutation test on the median interval. By June 2003 cancer had developed in 105 mother-offspring pairs within the cohort. Common sites among mothers were breast (47%), colorectal (9%), non-Hodgkin lymphoma (NHL) (8%) and cervix (7%), while for offspring in affected pairs common cancers were leukemia (12.4%), thyroid (13.3%), NHL (10.5%), breast (10.5%) and melanoma (7.6%). The median interval between diagnoses was 5.9 years, but for 33% of affected pairs the interval was < or =3 years. The probability of this occurring by chance alone was 0.03. This held true whether the offspring's or mother's diagnosis was first (P < 0.01). In a population-based cohort followed for three decades, the absolute interval between the diagnosis of cancer in mothers and their offspring is shorter than expected by chance. Explanations include shared environmental exposures or the possibility that cancer ascertainment in one pair member affects health behaviors in the other resulting in early diagnosis. The latter may bias the estimation of anticipation and survival in familial cancers.

  17. Intracalibration of particle detectors on a three-axis stabilized geostationary platform

    NASA Astrophysics Data System (ADS)

    Rowland, W.; Weigel, R. S.

    2012-11-01

    We describe an algorithm for intracalibration of measurements from plasma or energetic particle detectors on a three-axis stabilized platform. Modeling and forecasting of Earth's radiation belt environment requires data from particle instruments, and these data depend on measurements which have an inherent calibration uncertainty. Pre-launch calibration is typically performed, but on-orbit changes in the instrument often necessitate adjustment of calibration parameters to mitigate the effect of these changes on the measurements. On-orbit calibration practices for particle detectors aboard spin-stabilized spacecraft are well established. Three-axis stabilized platforms, however, pose unique challenges even when comparisons are being performed between multiple telescopes measuring the same energy ranges aboard the same satellite. This algorithm identifies time intervals when different telescopes are measuring particles with the same pitch angles. These measurements are used to compute scale factors which can be multiplied by the pre-launch geometric factor to correct any changes. The approach is first tested using measurements from GOES-13 MAGED particle detectors over a 5-month time period in 2010. We find statistically significant variations which are generally on the order of 5% or less. These results do not appear to be dependent on Poisson statistics nor upon whether a dead time correction was performed. When applied to data from a 5-month interval in 2011, one telescope shows a 10% shift from the 2010 scale factors. This technique has potential for operational use to help maintain relative calibration between multiple telescopes aboard a single satellite. It should also be extensible to inter-calibration between multiple satellites.

  18. The Scientific Legacy of Charles Wheatstone

    NASA Astrophysics Data System (ADS)

    Greenslade, Thomas B.

    2017-02-01

    Charles Wheatstone's name was once familiar to students because they used his eponymous bridge to measure resistances. That usage seems to be disappearing—we all have access to digital ohmmeters—but the techniques that he developed for making electrical measurements can still be used with profit. Also, his work with measuring very short time intervals and his work with musical acoustics are still with us, if in modified forms. Here are a few examples of his work.

  19. 47 CFR 15.303 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... measurement. (d) Isochronous devices. Devices that transmit at a regular interval, typified by time-division... Communications Service Devices § 15.303 Definitions. (a) Asynchronous devices. Devices that transmit RF energy at... with a fixed infrastructure or by disabling mechanisms to allow adequate coordination of their...

  20. Does controlling for biological maturity improve physical activity tracking?

    PubMed

    Erlandson, Marta C; Sherar, Lauren B; Mosewich, Amber D; Kowalski, Kent C; Bailey, Donald A; Baxter-Jones, Adam D G

    2011-05-01

    Tracking of physical activity through childhood and adolescence tends to be low. Variation in the timing of biological maturation within youth of the same chronological age (CA) might affect participation in physical activity and may partially explain the low tracking. To examine the stability of physical activity over time from childhood to late adolescence when aligned on CA and biological age (BA). A total of 91 males and 96 females aged 8-15 yr from the Saskatchewan Pediatric Bone Mineral Accrual Study (PBMAS) were assessed annually for 8 yr. BA was calculated as years from age at peak height velocity. Physical activity was assessed using the Physical Activity Questionnaire for Children/Adolescents. Tracking was analyzed using intraclass correlations for both CA and BA (2-yr groupings). To be included in the analysis, an individual required a measure at both time points within an interval; however, not all individuals were present at all tracking intervals. Physical activity tracking by CA 2-yr intervals were, in general, moderate in males (r=0.42-0.59) and females (r=0.43-0.44). However, the 9- to 11-yr CA interval was low and nonsignificant (r=0.23-0.30). Likewise, tracking of physical activity by BA 2-yr intervals was moderate to high in males (r=0.44-0.60) and females (r=0.39-0.62). Accounting for differences in the timing of biological maturity had little effect on tracking physical activity. However, point estimates for tracking are higher in early adolescence in males and to a greater extent in females when aligned by BA versus CA. This suggests that maturity may be more important in physical activity participation in females than males. © 2011 by the American College of Sports Medicine

  1. Implementation of a high precision multi-measurement time-to-digital convertor on a Kintex-7 FPGA

    NASA Astrophysics Data System (ADS)

    Kuang, Jie; Wang, Yonggang; Cao, Qiang; Liu, Chong

    2018-05-01

    Time-to-digital convertors (TDCs) based on field programmable gate array (FPGA) are becoming more and more popular. Multi-measurement is an effective method to improve TDC precision beyond the cell delay limitation. However, the implementation of TDC with multi-measurement on FPGAs manufactured with 28 nm and more advanced process is facing new challenges. Benefiting from the ones-counter encoding scheme, which was developed in our previous work, we implement a ring oscillator multi-measurement TDC on a Xilinx Kintex-7 FPGA. Using the two TDC channels to measure time-intervals in the range (0 ns-30 ns), the average RMS precision can be improved to 5.76 ps, meanwhile the logic resource usage remains the same with the one-measurement TDC, and the TDC dead time is only 22 ns. The investigation demonstrates that the multi-measurement methods are still available for current main-stream FPGAs. Furthermore, the new implementation in this paper could make the trade-off among the time precision, resource usage and TDC dead time better than ever before.

  2. Excess close burst pairs in FRB 121102

    NASA Astrophysics Data System (ADS)

    Katz, J. I.

    2018-05-01

    The repeating FRB 121102 emitted a pair of apparently discrete bursts separated by 37 ms and another pair, 131 d later, separated by 34 ms, during observations that detected bursts at a mean rate of ˜2 × 10-4 s-1. While FRB 121102 is known to produce multipeaked bursts, here I assume that these `burst pairs' are truly separate bursts and not multicomponent single bursts, and consider the implications of that assumption. Their statistics are then non-Poissonian. Assuming that the emission comes from a narrow range of rotational phase, then the measured burst intervals constrain any possible periodic modulation underlying the highly episodic emission. If more such short intervals are measured a period may be determined or periodicity may be excluded. The excess of burst intervals much shorter than their mean recurrence time may be explained if FRB emit steady but narrow beams that execute a random walk in direction, perhaps indicating origin in a black hole's accretion disc.

  3. Sensitivity, specificity, and reproducibility of four measures of laboratory turnaround time.

    PubMed

    Valenstein, P N; Emancipator, K

    1989-04-01

    The authors studied the performance of four measures of laboratory turnaround time: the mean, median, 90th percentile, and proportion of tests reported within a predetermined cut-off interval (proportion of acceptable tests [PAT]). Measures were examined with the use of turnaround time data from 11,070 stat partial thromboplastin times, 16,761 urine cultures, and 28,055 stat electrolyte panels performed by a single laboratory. For laboratories with long turnaround times, the most important quality of a turnaround time measure is high reproducibility, so that improvement in reporting speed can be distinguished from random variation resulting from sampling. The mean was found to be the most reproducible of the four measures, followed by the median. The mean achieved acceptable precision with sample sizes of 100-500 tests. For laboratories with normally rapid turnaround times, the most important quality of a measure is high sensitivity and specificity for detecting whether turnaround time has dropped below standards. The PAT was found to be the best measure of turnaround time in this setting but required sample sizes of at least 500 tests to achieve acceptable accuracy. Laboratory turnaround time may be measured for different reasons. The method of measurement should be chosen with an eye toward its intended application.

  4. The Event Related Brain Potential as an Index of Information Processing, Cognitive Activity, and Skill Acquisition: A Program of Basic Research.

    DTIC Science & Technology

    1985-02-28

    psychophysiological function in question. For example, for most measurements of the cardiovascular system, data are available only at each heart beat ...function of the duration of the charging period, *i . and hence will be proportional to the inter- beat interval (and inversely °°. • .*~* 14 information (0... beat interval. Thus, the output will lag the input. 2.3 Computer Access to Voltage x Time Functions 2.3.1 Digital Input and Analog-to-Digital Conversion

  5. Remote measurement of salinity: Repeated measurements over a single flight line near the Mississippi Sound

    NASA Technical Reports Server (NTRS)

    Thomann, G. C.

    1973-01-01

    Experiments to remotely determine sea water salinity from measurements of the sea surface radiometric temperature over the Mississippi Sound were conducted. The line was flown six times at an altitude of 244 meters. The radiometric temperature of the sea surface was measured in two spectral intervals. The specifications of the equipment and the conditions under which the tests were conducted are described. Results of the tests are presented in the form of graphs.

  6. The ceramics industry and lead poisoning. Long-term testing.

    PubMed

    De Rosa, E; Rossi, A; Toffolo, D; Brighenti, F; Rosa, A; Caroldi, S

    1980-12-01

    The investigation evaluates the efficiency attributed to some measures (improvements in environment, individual health habits) in reducing the risk of lead poisoning in the ceramics industry. The evaluation of the average levels of lead in the blood of 154 exposed workers was carried out in four plants at a time interval of six to eight months. The study considers the variations in relation to possible measures brought about during the interval. A reduction of environmental risk was in effect shown by a clear improvement in the blood lead levels, which still, however, exceeded the internationally recommended limits in many of the subjects. It was concluded that further improvements can only be made by reducing the lead content of the glazes used.

  7. A temporal discriminability account of children's eyewitness suggestibility.

    PubMed

    Bright-Paul, Alexandra; Jarrold, Christopher

    2009-07-01

    Children's suggestibility is typically measured using a three-stage 'event-misinformation-test' procedure. We examined whether suggestibility is influenced by the time delays imposed between these stages, and in particular whether the temporal discriminability of sources (event and misinformation) predicts performance. In a novel approach, the degree of source discriminability was calculated as the relative magnitude of two intervals (the ratio of event-misinformation and misinformation-test intervals), based on an adaptation of existing 'ratio-rule' accounts of memory. Five-year-olds (n =150) watched an event, and were exposed to misinformation, before memory for source was tested. The absolute event-test delay (12 versus 24 days) and the 'ratio' of event-misinformation/misinformation-test intervals (11:1, 3:1, 1:1, 1:3 and 1:11) were manipulated across participants. The temporal discriminability of sources, measured by the ratio, was indeed a strong predictor of suggestibility. Most importantly, if the ratio was constant (e.g. 18/6 versus 9/3 days), performance was remarkably similar despite variations in absolute delay (e.g. 24 versus 12 days). This intriguing finding not only extends the ratio-rule of distinctiveness to misinformation paradigms, but also serves to illustrate a new empirical means of differentiating between explanations of suggestibility based on interference between sources and disintegration of source information over time.

  8. The Amount of Time Dilation for Visual Flickers Corresponds to the Amount of Neural Entrainments Measured by EEG.

    PubMed

    Hashimoto, Yuki; Yotsumoto, Yuko

    2018-01-01

    The neural basis of time perception has long attracted the interests of researchers. Recently, a conceptual model consisting of neural oscillators was proposed and validated by behavioral experiments that measured the dilated duration in perception of a flickering stimulus (Hashimoto and Yotsumoto, 2015). The model proposed that flickering stimuli cause neural entrainment of oscillators, resulting in dilated time perception. In this study, we examined the oscillator-based model of time perception, by collecting electroencephalography (EEG) data during an interval-timing task. Initially, subjects observed a stimulus, either flickering at 10-Hz or constantly illuminated. The subjects then reproduced the duration of the stimulus by pressing a button. As reported in previous studies, the subjects reproduced 1.22 times longer durations for flickering stimuli than for continuously illuminated stimuli. The event-related potential (ERP) during the observation of a flicker oscillated at 10 Hz, reflecting the 10-Hz neural activity phase-locked to the flicker. Importantly, the longer reproduced duration was associated with a larger amplitude of the 10-Hz ERP component during the inter-stimulus interval, as well as during the presentation of the flicker. The correlation between the reproduced duration and the 10-Hz oscillation during the inter-stimulus interval suggested that the flicker-induced neural entrainment affected time dilation. While the 10-Hz flickering stimuli induced phase-locked entrainments at 10 Hz, we also observed event-related desynchronizations of spontaneous neural oscillations in the alpha-frequency range. These could be attributed to the activation of excitatory neurons while observing the flicker stimuli. In addition, neural activity at approximately the alpha frequency increased during the reproduction phase, indicating that flicker-induced neural entrainment persisted even after the offset of the flicker. In summary, our results suggest that the duration perception is mediated by neural oscillations, and that time dilation induced by flickering visual stimuli can be attributed to neural entrainment.

  9. Effects of varying doses of β-nerve growth factor on the timing of ovulation, plasma progesterone concentration and corpus luteum size in female alpacas (Vicugna pacos).

    PubMed

    Stuart, C C; Vaughan, J L; Kershaw-Young, C M; Wilkinson, J; Bathgate, R; de Graaf, S P

    2015-11-01

    Ovulation in camelids is induced by the seminal plasma protein ovulation-inducing factor (OIF), recently identified as β-nerve growth factor (β-NGF). The present study measured the total protein concentration in alpaca seminal plasma using a bicinchoninic acid (BCA) protein quantification assay and found it to be 22.2±2.0mgmL(-1). To measure the effects of varying doses of β-NGF on the incidence and timing of ovulation, corpus luteum (CL) size and plasma progesterone concentration, 24 female alpacas were synchronised and treated with either: (1) 1mL 0.9% saline (n=5); (2) 4µg buserelin (n=5); (3) 1mg β-NGF protein (n=5); (4) 0.1mg β-NGF (n=5); or (5) 0.01mg β-NGF (n=4). Females were examined by transrectal ultrasonography at 1-2-h intervals between 20 and 45h after treatment or until ovulation occurred, as well as on Day 8 to observe the size of the CL, at which time blood was collected to measure plasma progesterone concentrations. Ovulation was detected in 0/5, 5/5, 5/5, 3/5 and 0/4 female alpacas treated with saline, buserelin, 1, 0.1 and 0.01mg β-NGF, respectively. Mean ovulation interval (P=0.76), CL diameter (P=0.96) and plasma progesterone concentration (P=0.96) did not differ between treatments. Mean ovulation interval overall was 26.2±1.0h. In conclusion, buserelin and 1mg β-NGF are equally effective at inducing ovulation in female alpacas, but at doses ≤0.1mg, β-NGF is not a reliable method for the induction of ovulation.

  10. Are consonant intervals music to their ears? Spontaneous acoustic preferences in a nonhuman primate.

    PubMed

    McDermott, Josh; Hauser, Marc

    2004-12-01

    Humans find some sounds more pleasing than others; such preferences may underlie our enjoyment of music. To gain insight into the evolutionary origins of these preferences, we explored whether they are present in other animals. We designed a novel method to measure the spontaneous sound preferences of cotton-top tamarins, a species that has been extensively tested for other perceptual abilities. Animals were placed in a V-shaped maze, and their position within the maze controlled their auditory environment. One sound was played when they were in one branch of the maze, and a different sound for the opposite branch; no food was delivered during testing. We used the proportion of time spent in each branch as a measure of preference. The first two experiments were designed as tests of our method. In Experiment 1, we used loud and soft white noise as stimuli; all animals spent most of their time on the side with soft noise. In Experiment 2, tamarins spent more time on the side playing species-specific feeding chirps than on the side playing species-specific distress calls. Together, these two experiments suggest that the method is effective, providing a spontaneous measure of preference. In Experiment 3, however, subjects showed no preference for consonant over dissonant intervals. Finally, tamarins showed no preference in Experiment 4 for a screeching sound (comparable to fingernails on a blackboard) over amplitude-matched white noise. In contrast, humans showed clear preferences for the consonant intervals of Experiment 3 and the white noise of Experiment 4 using the same stimuli and a similar method. We conclude that tamarins' preferences differ qualitatively from those of humans. The preferences that support our capacity for music may, therefore, be unique among the primates, and could be music-specific adaptations.

  11. Comparison of polar cap potential drops estimated from solar wind and ground magnetometer data - CDAW 6

    NASA Technical Reports Server (NTRS)

    Reiff, P. H.; Spiro, R. W.; Wolf, R. A.; Kamide, Y.; King, J. H.

    1985-01-01

    It is pointed out that the maximum electrostatic potential difference across the polar cap, Phi, is a fundamental measure of the coupling between the solar wind and the earth's magnetosphere/ionosphere sytem. During the Coordinated Data Analysis Workshop (CDAW) 6 intervals, no suitably instrumented spacecraft was in an appropriate orbit to determine the polar-cap potential drop directly. However, two recently developed independent techniques make it possible to estimate the polar-cap potential drop for times when direct spacecraft data are not available. The present investigation is concerned with a comparison of cross-polar-cap potential drop estimates calculated for the two CDAW 6 intervals on the basis of these two techniques. In the case of one interval, the agreement between the potential drops and Joule heating rates is relatively good. In the second interval, however, the agreement is not very good. Explanations for this discrepancy are discussed.

  12. Use of the iPhone for Cobb angle measurement in scoliosis.

    PubMed

    Shaw, Matthew; Adam, Clayton J; Izatt, Maree T; Licina, Paul; Askin, Geoffrey N

    2012-06-01

    The Cobb technique is the universally accepted method for measuring the severity of spinal deformities. Traditionally, Cobb angles have been measured using protractor and pencil on hardcopy radiographic films. The new generation of mobile 'smartphones' make accurate angle measurement possible using an integrated accelerometer, providing a potentially useful clinical tool for assessing Cobb angles. The purpose of this study was to compare Cobb angle measurements performed using a smartphone and traditional protractor in a series of 20 adolescent idiopathic scoliosis patients. Seven observers measured major Cobb angles on 20 pre-operative postero-anterior radiographs of Adolescent Idiopathic Scoliosis patients with both a standard protractor and using an Apple iPhone. Five of the observers repeated the measurements at least a week after the original measurements. The mean absolute difference between pairs of smartphone/protractor measurements was 2.1°, with a small (1°) bias toward lower Cobb angles with the iPhone. 95% confidence intervals for intra-observer variability were ±3.3° for the protractor and ±3.9° for the iPhone. 95% confidence intervals for inter-observer variability were ±8.3° for the iPhone and ±7.1° for the protractor. Both of these confidence intervals were within the range of previously published Cobb measurement studies. We conclude that the iPhone is an equivalent Cobb measurement tool to the manual protractor, and measurement times are about 15% less. The widespread availability of inclinometer-equipped mobile phones and the ability to store measurements in later versions of the angle measurement software may make these new technologies attractive for clinical measurement applications.

  13. Neural substrates of time perception and impulsivity

    PubMed Central

    Wittmann, Marc; Simmons, Alan N.; Flagan, Taru; Lane, Scott D.; Wackermann, Jiří; Paulus, Martin P.

    2011-01-01

    Several studies provide empirical evidence for the association between impulsivity and time perception. However, little is known about the neural substrates underlying this function. This investigation examined the influence of impulsivity on neural activation patterns during the encoding and reproduction of intervals with durations of 3, 9 and 18 seconds using event-related functional magnetic resonance imaging (fMRI). Twenty-seven subjects participated in this study, including 15 high impulsive subjects that were classified based on their self-rating. FMRI activation during the duration reproduction task was correlated with measures of two self-report questionnaires related to the concept of impulsivity (Barratt Impulsiveness Scale, BIS; Zimbardo Time Perspective Inventory, ZTPI). Behaviorally, those individuals who under-reproduced temporal intervals also showed lower scores on the ZTPI future perspective subscale and higher scores on the BIS. FMRI activation revealed an accumulating pattern of neural activity peaking at the end of the 9- and 18-s interval within right posterior insula. Activations of brain regions during the reproduction phase of the timing task, such as those related to motor execution as well as to the ‘core control network’ – encompassing the inferior frontal and medial frontal cortex, the anterior insula as well as the inferior parietal cortex – were significantly correlated with reproduced duration, as well as with BIS and ZTPI subscales. In particular, the greater activation in these regions the shorter were the reproduced intervals, the more impulsive was an individual and the less pronounced the future perspective. Activation in the core control network, thus, may form a biological marker for cognitive time management and for impulsiveness. PMID:21763642

  14. Repeated measurements of mite and pet allergen levels in house dust over a time period of 8 years.

    PubMed

    Antens, C J M; Oldenwening, M; Wolse, A; Gehring, U; Smit, H A; Aalberse, R C; Kerkhof, M; Gerritsen, J; de Jongste, J C; Brunekreef, B

    2006-12-01

    Studies of the association between indoor allergen exposure and the development of allergic diseases have often measured allergen exposure at one point in time. We investigated the variability of house dust mite (Der p 1, Der f 1) and cat (Fel d 1) allergen in Dutch homes over a period of 8 years. Data were obtained in the Dutch PIAMA birth cohort study. Dust from the child's mattress, the parents' mattress and the living room floor was collected at four points in time, when the child was 3 months, 4, 6 and 8 years old. Dust samples were analysed for Der p 1, Der f 1 and Fel d 1 by sandwich enzyme immuno assay. Mite allergen concentrations for the child's mattress, the parents' mattress and the living room floor were moderately correlated between time-points. Agreement was better for cat allergen. For Der p 1 and Der f 1 on the child's mattress, the within-home variance was close to or smaller than the between-home variance in most cases. For Fel d 1, the within-home variance was almost always smaller than the between-home variance. Results were similar for allergen levels expressed per gram of dust and allergen levels expressed per square metre of the sampled surface. Variance ratios were smaller when samples were taken at shorter time intervals than at longer time intervals. Over a period of 4 years, mite and cat allergens measured in house dust are sufficiently stable to use single measurements with confidence in epidemiological studies. The within-home variance was larger when samples were taken 8 years apart so that over such long periods, repetition of sampling is recommended.

  15. Automated and Clinical Breast Imaging Reporting and Data System Density Measures Predict Risk for Screen-Detected and Interval Cancers: A Case-Control Study.

    PubMed

    Kerlikowske, Karla; Scott, Christopher G; Mahmoudzadeh, Amir P; Ma, Lin; Winham, Stacey; Jensen, Matthew R; Wu, Fang Fang; Malkov, Serghei; Pankratz, V Shane; Cummings, Steven R; Shepherd, John A; Brandt, Kathleen R; Miglioretti, Diana L; Vachon, Celine M

    2018-06-05

    In 30 states, women who have had screening mammography are informed of their breast density on the basis of Breast Imaging Reporting and Data System (BI-RADS) density categories estimated subjectively by radiologists. Variation in these clinical categories across and within radiologists has led to discussion about whether automated BI-RADS density should be reported instead. To determine whether breast cancer risk and detection are similar for automated and clinical BI-RADS density measures. Case-control. San Francisco Mammography Registry and Mayo Clinic. 1609 women with screen-detected cancer, 351 women with interval invasive cancer, and 4409 matched control participants. Automated and clinical BI-RADS density assessed on digital mammography at 2 time points from September 2006 to October 2014, interval and screen-detected breast cancer risk, and mammography sensitivity. Of women whose breast density was categorized by automated BI-RADS more than 6 months to 5 years before diagnosis, those with extremely dense breasts had a 5.65-fold higher interval cancer risk (95% CI, 3.33 to 9.60) and a 1.43-fold higher screen-detected risk (CI, 1.14 to 1.79) than those with scattered fibroglandular densities. Associations of interval and screen-detected cancer with clinical BI-RADS density were similar to those with automated BI-RADS density, regardless of whether density was measured more than 6 months to less than 2 years or 2 to 5 years before diagnosis. Automated and clinical BI-RADS density measures had similar discriminatory accuracy, which was higher for interval than screen-detected cancer (c-statistics: 0.70 vs. 0.62 [P < 0.001] and 0.72 vs. 0.62 [P < 0.001], respectively). Mammography sensitivity was similar for automated and clinical BI-RADS categories: fatty, 93% versus 92%; scattered fibroglandular densities, 90% versus 90%; heterogeneously dense, 82% versus 78%; and extremely dense, 63% versus 64%, respectively. Neither automated nor clinical BI-RADS density was assessed on tomosynthesis, an emerging breast screening method. Automated and clinical BI-RADS density similarly predict interval and screen-detected cancer risk, suggesting that either measure may be used to inform women of their breast density. National Cancer Institute.

  16. Surgical timing after chemoradiotherapy for rectal cancer, analysis of technique (STARRCAT): results of a feasibility multi-centre randomized controlled trial.

    PubMed

    Foster, J D; Ewings, P; Falk, S; Cooper, E J; Roach, H; West, N P; Williams-Yesson, B A; Hanna, G B; Francis, N K

    2016-10-01

    The optimal time of rectal resection after long-course chemoradiotherapy (CRT) remains unclear. A feasibility study was undertaken for a multi-centre randomized controlled trial evaluating the impact of the interval after chemoradiotherapy on the technical complexity of surgery. Patients with rectal cancer were randomized to either a 6- or 12-week interval between CRT and surgery between June 2012 and May 2014 (ISRCTN registration number: 88843062). For blinded technical complexity assessment, the Observational Clinical Human Reliability Analysis technique was used to quantify technical errors enacted within video recordings of operations. Other measured outcomes included resection completeness, specimen quality, radiological down-staging, tumour cell density down-staging and surgeon-reported technical complexity. Thirty-one patients were enrolled: 15 were randomized to 6 and 16-12 weeks across 7 centres. Fewer eligible patients were identified than had been predicted. Of 23 patients who underwent resection, mean 12.3 errors were observed per case at 6 weeks vs. 10.7 at 12 weeks (p = 0.401). Other measured outcomes were similar between groups. The feasibility of measurement of operative performance of rectal cancer surgery as an endpoint was confirmed in this exploratory study. Recruitment of sufficient numbers of patients represented a challenge, and a proportion of patients did not proceed to resection surgery. These results suggest that interval after CRT may not substantially impact upon surgical technical performance.

  17. Periodic collapse and long-time evolution of strong Langmuir turbulence

    NASA Astrophysics Data System (ADS)

    Cheung, P. Y.; Wong, A. Y.

    1985-10-01

    Experimental measurements on the long-time evolution of strong Langmuir turbulence in a beam-plasma system reveal a picture of periodic, short bursts of Langmuir wave collapse instead of the existence of long-lived solitons. The remnants of density cavities from burnout cavitons are observed to curtail wave growth periodically, creating time intervals of low wave activity between successive cycles of wave collapse, and establishing three regimes of wave evolution.

  18. Proceedings of the Annual Precise Time and Time Interval (PTTI) Planning Meeting (6th). Held at U.S. Naval Research Laboratory, December 3-5, 1974

    DTIC Science & Technology

    1974-01-01

    General agreement seems to be developing that the geophysical system should be defined in terms of a large number of points...34A Laser-Interferometer System for the Absolute Determination of the Acceleration due to Gravity," In Proc. Int. Conf. on Precision Measurement...MO %. The ratio of the plasmaspheric to the total time-delays due to free

  19. Time-dependent influence of sensorimotor set on automatic responses in perturbed stance

    NASA Technical Reports Server (NTRS)

    Chong, R. K.; Horak, F. B.; Woollacott, M. H.; Peterson, B. W. (Principal Investigator)

    1999-01-01

    These experiments tested the hypothesis that the ability to change sensorimotor set quickly for automatic responses depends on the time interval between successive surface perturbations. Sensorimotor set refers to the influence of prior experience or context on the state of the sensorimotor system. Sensorimotor set for postural responses was influenced by first giving subjects a block of identical backward translations of the support surface, causing forward sway and automatic gastrocnemius responses. The ability to change set quickly was inferred by measuring the suppression of the stretched antagonist gastrocnemius responses to toes-up rotations causing backward sway, following the translations. Responses were examined under short (10-14 s) and long (19-24 s) inter-trial intervals in young healthy subjects. The results showed that subjects in the long-interval group changed set immediately by suppressing gastrocnemius to 51% of translation responses within the first rotation and continued to suppress them over succeeding rotations. In contrast, subjects in the short-interval group did not change set immediately, but required two or more rotations to suppress gastrocnemius responses. By the last rotation, the short-interval group suppressed gastrocnemius responses to 33%, similar to the long-interval group of 29%. Associated surface plantarflexor torque resulting from these responses showed similar results. When rotation and translation perturbations alternated, however, the short-interval group was not able to suppress gastrocnemius responses to rotations as much as the long-interval group, although they did suppress more than in the first rotation trial after a series of translations. Set for automatic responses appears to linger, from one trial to the next. Specifically, sensorimotor set is more difficult to change when surface perturbations are given in close succession, making it appear as if set has become progressively stronger. A strong set does not mean that responses become larger over consecutive trials. Rather, it is inferred by the extent of difficulty in changing a response when it is appropriate to do so. These results suggest that the ability to change sensorimotor set quickly is sensitive to whether the change is required after a long or a short series of a prior different response, which in turn depends on the time interval between successive trials. Different rate of gastrocnemius suppression to toes-up rotation of the support surface have been reported in previous studies. This may be partially explained by different inter-trial time intervals demonstrated in this study.

  20. Method and Apparatus for Evaluating Multilayer Objects for Imperfections

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S. (Inventor); Abedin, Nurul (Inventor); Sun, Kuen J. (Inventor)

    1999-01-01

    A multilayer object having multiple layers arranged in a stacking direction is evaluated for imperfections such as voids, delaminations and microcracks. First. an acoustic wave is transmitted into the object in the stacking direction via an appropriate transducer/waveguide combination. The wave propagates through the multilayer object and is received by another transducer/waveguide combination preferably located on the same surface as the transmitting combination. The received acoustic wave is correlated with the presence or absence of imperfections by, e.g., generating pulse echo signals indicative of the received acoustic wave. wherein the successive signals form distinct groups over time. The respective peak amplitudes of each group are sampled and curve fit to an exponential curve. wherein a substantial fit of approximately 80-90% indicates an absence of imperfections and a significant deviation indicates the presence of imperfections. Alternatively, the time interval between distinct groups can be measured. wherein equal intervals indicate the absence of imperfections and unequal intervals indicate the presence of imperfections.

  1. Method and apparatus for evaluating multilayer objects for imperfections

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S. (Inventor); Abedin, Nurul (Inventor); Sun, Kuen J. (Inventor)

    1997-01-01

    A multilayer object having multiple layers arranged in a stacking direction is evaluated for imperfections such as voids, delaminations and microcracks. First, an acoustic wave is transmitted into the object in the stacking direction via an appropriate transducer/waveguide combination. The wave propagates through the multilayer object and is received by another transducer/waveguide combination preferably located on the same surface as the transmitting combination. The received acoustic wave is correlated with the presence or absence of imperfections by, e.g., generating pulse echo signals indicative of the received acoustic wave, wherein the successive signals form distinct groups over time. The respective peak amplitudes of each group are sampled and curve fit to an exponential curve, wherein a substantial fit of approximately 80-90% indicates an absence of imperfections and a significant deviation indicates the presence of imperfections. Alternatively, the time interval between distinct groups can be measured, wherein equal intervals indicate the absence of imperfections and unequal intervals indicate the presence of imperfections.

  2. Realtime Multichannel System for Beat to Beat QT Interval Variability

    NASA Technical Reports Server (NTRS)

    Starc, Vito; Schlegel, Todd T.

    2006-01-01

    The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.

  3. Atomic motion from the mean square displacement in a monatomic liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallace, Duane C.; De Lorenzi-Venneri, Giulia; Chisolm, Eric D.

    V-T theory is constructed in the many-body Hamiltonian formulation, and is being developed as a novel approach to liquid dynamics theory. In this theory the liquid atomic motion consists of two contributions, normal mode vibrations in a single representative potential energy valley, and transits, which carry the system across boundaries between valleys. The mean square displacement time correlation function (the MSD) is a direct measure of the atomic motion, and our goal is to determine if the V-T formalism can produce a physically sensible account of this motion. We employ molecular dynamics (MD) data for a system representing liquid Na,more » and find the motion evolves in three successive time intervals: on the first 'vibrational' interval, the vibrational motion alone gives a highly accurate account of the MD data; on the second 'crossover' interval, the vibrational MSD saturates to a constant while the transit motion builds up from zero; on the third 'random walk' interval, the transit motion produces a purely diffusive random walk of the vibrational equilibrium positions. Furthermore, this motional evolution agrees with, and adds refinement to, the MSD atomic motion as described by current liquid dynamics theories.« less

  4. Atomic motion from the mean square displacement in a monatomic liquid

    DOE PAGES

    Wallace, Duane C.; De Lorenzi-Venneri, Giulia; Chisolm, Eric D.

    2016-04-08

    V-T theory is constructed in the many-body Hamiltonian formulation, and is being developed as a novel approach to liquid dynamics theory. In this theory the liquid atomic motion consists of two contributions, normal mode vibrations in a single representative potential energy valley, and transits, which carry the system across boundaries between valleys. The mean square displacement time correlation function (the MSD) is a direct measure of the atomic motion, and our goal is to determine if the V-T formalism can produce a physically sensible account of this motion. We employ molecular dynamics (MD) data for a system representing liquid Na,more » and find the motion evolves in three successive time intervals: on the first 'vibrational' interval, the vibrational motion alone gives a highly accurate account of the MD data; on the second 'crossover' interval, the vibrational MSD saturates to a constant while the transit motion builds up from zero; on the third 'random walk' interval, the transit motion produces a purely diffusive random walk of the vibrational equilibrium positions. Furthermore, this motional evolution agrees with, and adds refinement to, the MSD atomic motion as described by current liquid dynamics theories.« less

  5. Emotion processing in the visual brain: a MEG analysis.

    PubMed

    Peyk, Peter; Schupp, Harald T; Elbert, Thomas; Junghöfer, Markus

    2008-06-01

    Recent functional magnetic resonance imaging (fMRI) and event-related brain potential (ERP) studies provide empirical support for the notion that emotional cues guide selective attention. Extending this line of research, whole head magneto-encephalogram (MEG) was measured while participants viewed in separate experimental blocks a continuous stream of either pleasant and neutral or unpleasant and neutral pictures, presented for 330 ms each. Event-related magnetic fields (ERF) were analyzed after intersubject sensor coregistration, complemented by minimum norm estimates (MNE) to explore neural generator sources. Both streams of analysis converge by demonstrating the selective emotion processing in an early (120-170 ms) and a late time interval (220-310 ms). ERF analysis revealed that the polarity of the emotion difference fields was reversed across early and late intervals suggesting distinct patterns of activation in the visual processing stream. Source analysis revealed the amplified processing of emotional pictures in visual processing areas with more pronounced occipito-parieto-temporal activation in the early time interval, and a stronger engagement of more anterior, temporal, regions in the later interval. Confirming previous ERP studies showing facilitated emotion processing, the present data suggest that MEG provides a complementary look at the spread of activation in the visual processing stream.

  6. Clinical significance of the infection-free interval in the management of acute bacterial exacerbations of chronic bronchitis.

    PubMed

    Chodosh, Sanford

    2005-06-01

    Rational and appropriate antibiotic use for patients with acute exacerbation of chronic bronchitis (AECB) is a major concern, as approximately half of these patients do not have a bacterial infection. Typically, the result of antimicrobial therapy for patients with acute bacterial exacerbation of chronic bronchitis (ABECB) is not eradication of the pathogen but resolution of the acute symptoms. However, the length of time before the next bacterial exacerbation can be another important variable, as the frequency of exacerbations will affect the overall health of the patient and the rate of lung deterioration over time. Clinical trials comparing antimicrobial therapies commonly measure resolution of symptoms in AECB patients as the primary end point, regardless of whether the exacerbation is documented as bacterial in nature. Ideally, the scientific approach to assessing the efficacy of antibiotic therapy for ABECB should include a measurement of acute bacterial eradication rates in patients with documented bronchial bacterial infection followed by measurement of the infection-free interval (IFI), ie, the time to the next ABECB. The use of these variables can provide a standard for comparing various antimicrobial therapies. As we learn more about how antibiotics can affect the IFI, treatment decisions should be adapted to ensure optimal management of ABECB for the long-term.

  7. Real-time fluorescence microscopy monitoring of porphyrin biodistribution

    NASA Astrophysics Data System (ADS)

    Kimel, Sol; Gottfried, Varda; Kunzi-Rapp, Karin; Akguen, Nermin; Schneckenburger, Herbert

    1996-01-01

    In vivo uptake of the natural porphyrins, uroporphyrin III (UP), coproporphyrin III (CP) and protoporphyrin IX (PP), was monitored by fluorescence microscopy. Experiments were performed using the chick chorioallantoic membrane (CAM) model, which allowed video documentation of fluorescence both in real time and after integration over a chosen time interval (usually 2 s). Sensitizers at a concentration of 50 (mu) M (100 (mu) L) were injected into a medium-sized vein (diameter approximately 40 micrometer) using an ultra-fine 10 micrometer diameter needle. Fluorescence images were quantitated by subtracting the fluorescence intensity of surrounding CAM tissue (Fmatrix) from the intravascular fluorescence intensity (Fintravascular), after transformation of the video frames into digital form. The differential fluorescence intensity, Fintravascular - Fmatrix, is a measure of the biodistribution. Real time measurements clearly showed that CP and UP fluorescence is associated with moving erythrocytes and not with endothelial cells of the vessel wall. Fluorescence intensity was monitored, up to 60 minutes after injection, by averaging the fluorescence over time intervals of 2 s and recording the integrated images. The fluorescence intensity reached its maximum in about 20 - 30 min after injection, presumably after monomerization inside erythrocyte membranes. The results are interpreted in terms of physical-chemical characteristics (e.g. hydrophilicity) and correlated with the photodynamically induced hemostasis in CAM blood vessels.

  8. Effects of time and sampling location on concentrations of β-hydroxybutyric acid in dairy cows.

    PubMed

    Mahrt, A; Burfeind, O; Heuwieser, W

    2014-01-01

    Two trials were conducted to examine factors potentially influencing the measurement of blood β-hydroxybutyric acid (BHBA) in dairy cows. The objective of the first trial was to study effects of sampling time on BHBA concentration in continuously fed dairy cows. Furthermore, we determined test characteristics of a single BHBA measurement at a random time of the day to diagnose subclinical ketosis considering commonly used cut-points (1.2 and 1.4 mmol/L). Finally, we set out to evaluate if test characteristics could be enhanced by repeating measurements after different time intervals. During 4 herd visits, a total of 128 cows (8 to 28 d in milk) fed 10 times daily were screened at 0900 h and preselected by BHBA concentration. Blood samples were drawn from the tail vessels and BHBA concentrations were measured using an electronic BHBA meter (Precision Xceed, Abbott Diabetes Care Ltd., Witney, UK). Cows with BHBA concentrations ≥0.8 mmol/L at this time were enrolled in the trial (n=92). Subsequent BHBA measurements took place every 3h for a total of 8 measurements during 24 h. The effect of sampling time on BHBA concentrations was tested in a repeated-measures ANOVA repeating sampling time. Sampling time did not affect BHBA concentrations in continuously fed dairy cows. Defining the average daily BHBA concentration calculated from the 8 measurements as the gold standard, a single measurement at a random time of the day to diagnose subclinical ketosis had a sensitivity of 0.90 or 0.89 at the 2 BHBA cut-points (1.2 and 1.4 mmol/L). Specificity was 0.88 or 0.90 using the same cut-points. Repeating measurements after different time intervals improved test characteristics only slightly. In the second experiment, we compared BHBA concentrations of samples drawn from 3 different blood sampling locations (tail vessels, jugular vein, and mammary vein) of 116 lactating dairy cows. Concentrations of BHBA differed in samples from the 3 sampling locations. Mean BHBA concentration was 0.3 mmol/L lower when measured in the mammary vein compared with the jugular vein and 0.4 mmol/L lower in the mammary vein compared with the tail vessels. We conclude that to measure BHBA, blood samples of continuously fed dairy cows can be drawn at any time of the day. A single measurement provides very good test characteristics for on-farm conditions. Blood samples for BHBA measurement should be drawn from the jugular vein or tail vessels; the mammary vein should not be used for this purpose. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Importance of the Time Interval between Bowel Preparation and Colonoscopy in Determining the Quality of Bowel Preparation for Full-Dose Polyethylene Glycol Preparation

    PubMed Central

    Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan

    2014-01-01

    Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750

  10. Polysomnographic Measurement of Sleep Duration and Bodily Pain Perception in the Sleep Heart Health Study.

    PubMed

    Weingarten, Jeremy A; Dubrovsky, Boris; Basner, Robert C; Redline, Susan; George, Liziamma; Lederer, David J

    2016-08-01

    To determine whether total sleep time (TST) and specific sleep stage duration are associated with bodily pain perception and whether sex, age, or subjective sleepiness modifies this relationship. Data from adults ages 39-90 y (n = 5,199) who took part in the Sleep Heart Health Study Exam 1 were analyzed. TST, rapid eye movement (REM) sleep time, and slow wave sleep (SWS) time were measured by unattended, in-home nocturnal polysomnography. Bodily pain perception was measured via the Short Form-36 questionnaire bodily pain component. We used logistic regression to examine associations between total and individual sleep stage durations and bodily pain perception controlling for age, sex, race, body mass index, apnea-hypopnea index, antidepressant use, and important cardiovascular conditions (smoking [pack-years], history of diabetes, and history of percutaneous coronary intervention and/or coronary artery bypass graft). In the fully adjusted model, REM sleep time and SWS time were not associated with "moderate to severe pain," whereas TST was: Each 1-h decrement in TST was associated with a 7% increased odds of "moderate to severe pain" (odds ratio 1.07, 95% confidence interval 1.002, 1.14). Due to modification of the association between SWS time and "moderate to severe pain" by sex (P for interaction = 0.01), we performed analyses stratified by sex: Each 1-h decrement in SWS time was associated with a 20% higher odds of "moderate to severe pain" among men (odds ratio 1.20, 95% confidence interval 1.03-1.42) whereas an association was not observed among women. Shorter TST among all subjects and shorter SWS time in men was associated with "moderate to severe pain." REM sleep time was not associated with bodily pain perception in this cohort. © 2016 Associated Professional Sleep Societies, LLC.

  11. Integrating Behavioral Health in Primary Care Using Lean Workflow Analysis: A Case Study.

    PubMed

    van Eeghen, Constance; Littenberg, Benjamin; Holman, Melissa D; Kessler, Rodger

    2016-01-01

    Primary care offices are integrating behavioral health (BH) clinicians into their practices. Implementing such a change is complex, difficult, and time consuming. Lean workflow analysis may be an efficient, effective, and acceptable method for use during integration. The objectives of this study were to observe BH integration into primary care and to measure its impact. This was a prospective, mixed-methods case study in a primary care practice that served 8,426 patients over a 17-month period, with 652 patients referred to BH services. Secondary measures included primary care visits resulting in BH referrals, referrals resulting in scheduled appointments, time from referral to the scheduled appointment, and time from the referral to the first visit. Providers and staff were surveyed on the Lean method. Referrals increased from 23 to 37 per 1000 visits (P < .001). Referrals resulted in more scheduled (60% to 74%; P < .001) and arrived visits (44% to 53%; P = .025). Time from referral to the first scheduled visit decreased (hazard ratio, 1.60; 95% confidence interval, 1.37-1.88) as did time to first arrived visit (hazard ratio, 1.36; 95% confidence interval, 1.14-1.62). Survey responses and comments were positive. This pilot integration of BH showed significant improvements in treatment initiation and other measures. Strengths of Lean analysis included workflow improvement, system perspective, and project success. Further evaluation is indicated. © Copyright 2016 by the American Board of Family Medicine.

  12. Control Chart on Semi Analytical Weighting

    NASA Astrophysics Data System (ADS)

    Miranda, G. S.; Oliveira, C. C.; Silva, T. B. S. C.; Stellato, T. B.; Monteiro, L. R.; Marques, J. R.; Faustino, M. G.; Soares, S. M. V.; Ulrich, J. C.; Pires, M. A. F.; Cotrim, M. E. B.

    2018-03-01

    Semi-analytical balance verification intends to assess the balance performance using graphs that illustrate measurement dispersion, trough time, and to demonstrate measurements were performed in a reliable manner. This study presents internal quality control of a semi-analytical balance (GEHAKA BG400) using control charts. From 2013 to 2016, 2 weight standards were monitored before any balance operation. This work intended to evaluate if any significant difference or bias were presented on weighting procedure over time, to check the generated data reliability. This work also exemplifies how control intervals are established.

  13. Interresponse Time Structures in Variable-Ratio and Variable-Interval Schedules

    ERIC Educational Resources Information Center

    Bowers, Matthew T.; Hill, Jade; Palya, William L.

    2008-01-01

    The interresponse-time structures of pigeon key pecking were examined under variable-ratio, variable-interval, and variable-interval plus linear feedback schedules. Whereas the variable-ratio and variable-interval plus linear feedback schedules generally resulted in a distinct group of short interresponse times and a broad distribution of longer…

  14. Relative-Error-Covariance Algorithms

    NASA Technical Reports Server (NTRS)

    Bierman, Gerald J.; Wolff, Peter J.

    1991-01-01

    Two algorithms compute error covariance of difference between optimal estimates, based on data acquired during overlapping or disjoint intervals, of state of discrete linear system. Provides quantitative measure of mutual consistency or inconsistency of estimates of states. Relative-error-covariance concept applied, to determine degree of correlation between trajectories calculated from two overlapping sets of measurements and construct real-time test of consistency of state estimates based upon recently acquired data.

  15. Estimating average annual per cent change in trend analysis

    PubMed Central

    Clegg, Limin X; Hankey, Benjamin F; Tiwari, Ram; Feuer, Eric J; Edwards, Brenda K

    2009-01-01

    Trends in incidence or mortality rates over a specified time interval are usually described by the conventional annual per cent change (cAPC), under the assumption of a constant rate of change. When this assumption does not hold over the entire time interval, the trend may be characterized using the annual per cent changes from segmented analysis (sAPCs). This approach assumes that the change in rates is constant over each time partition defined by the transition points, but varies among different time partitions. Different groups (e.g. racial subgroups), however, may have different transition points and thus different time partitions over which they have constant rates of change, making comparison of sAPCs problematic across groups over a common time interval of interest (e.g. the past 10 years). We propose a new measure, the average annual per cent change (AAPC), which uses sAPCs to summarize and compare trends for a specific time period. The advantage of the proposed AAPC is that it takes into account the trend transitions, whereas cAPC does not and can lead to erroneous conclusions. In addition, when the trend is constant over the entire time interval of interest, the AAPC has the advantage of reducing to both cAPC and sAPC. Moreover, because the estimated AAPC is based on the segmented analysis over the entire data series, any selected subinterval within a single time partition will yield the same AAPC estimate—that is it will be equal to the estimated sAPC for that time partition. The cAPC, however, is re-estimated using data only from that selected subinterval; thus, its estimate may be sensitive to the subinterval selected. The AAPC estimation has been incorporated into the segmented regression (free) software Joinpoint, which is used by many registries throughout the world for characterizing trends in cancer rates. Copyright © 2009 John Wiley & Sons, Ltd. PMID:19856324

  16. Longitudinal evaluation of the microleakage of dentin bonding agents used to seal resected root apices.

    PubMed

    Vignaroli, P A; Anderson, R W; Pashley, D H

    1995-10-01

    A material that bonds to dentin and seals both the root canal and exposed dentinal tubules would be desirable following root resection. The purpose of this study was to measure the sealing ability of four dentin bonding agents on the resected root end. The bonding systems evaluated were Amalgambond (AMB), Scotchbond Multi-Purpose (SMP), Prisma Universal Bond 3 (PUB 3), and All-Bond 2 (AB2). All materials were applied directly to the resected root end without a class I preparation. One-half of the roots in each group were contaminated with human blood before bonding. Microleakage was measured using fluid filtration at various time intervals from 1 to 24 wk. Results indicated that all dentin bonding agents significantly reduced apical microleakage compared with prebonded controls at all time intervals. Blood contamination did not adversely affect the sealing ability of AMB, PUB 3, or SMP. The blood-contaminated AB2 group displayed significantly greater microleakage after 12 and 24 wk than the uncontaminated roots.

  17. Tangential velocity measurement using interferometric MTI radar

    DOEpatents

    Doerry, Armin W.; Mileshosky, Brian P.; Bickel, Douglas L.

    2006-01-03

    Radar systems use time delay measurements between a transmitted signal and its echo to calculate range to a target. Ranges that change with time cause a Doppler offset in phase and frequency of the echo. Consequently, the closing velocity between target and radar can be measured by measuring the Doppler offset of the echo. The closing velocity is also known as radial velocity, or line-of-sight velocity. Doppler frequency is measured in a pulse-Doppler radar as a linear phase shift over a set of radar pulses during some Coherent Processing Interval (CPI). An Interferometric Moving Target Indicator (MTI) radar can be used to measure the tangential velocity component of a moving target. Multiple baselines, along with the conventional radial velocity measurement, allow estimating the true 3-D velocity of a target.

  18. 3D time-lapse Electrical Resistivity Tomography (ERT) to monitor subsurface flow processes during a sprinkling and injection experiment on a mountain slope

    NASA Astrophysics Data System (ADS)

    Inauen, C.; Green, A.; Rabenstein, L.; Greenhalgh, S.; Kinzelbach, W.; Doetsch, J.; Hertrich, M.; Smoorenburg, M.; Volze, N.

    2012-04-01

    Understanding the relationships between precipitation volumes, surface runoff and subsurface storage, drainage and flow processes on mountain slopes is critical for flood management in alpine regions. In the Schächen catchment (central Switzerland) an unexpectedly delayed and heavy flood reaction to a long duration rainfall event was observed in 2005. It is believed that the steep creeping landmass slopes with thick soils were responsible for the delay. To better comprehend and visualise water infiltration and runoff formation we conducted a 3D time-lapse ERT experiment during a water sprinkling and injection experiment on the side of a hill in the Schächental region presumed representative of soil and other conditions associated with the delayed flood. Constant sprinkling at a rate of about 10mm/h was applied to a plot of area 30m x 5m. The electrical conductivity of the sprinkled water was approximately that of the pore water (25mS/m). A total of 33 consecutive ERT data sets, each comprising 3521 measured electrode configurations, were recorded with a 96-electrode array over an area of 27.5m x 14m, which included two thirds of the sprinkled area. Each electrode configuration was measured at a repeat interval of 2 to 2.8 hours. The entire 3D ERT monitoring experiment was divided into two separate time intervals: (1) the initial 25 hour period involving only freshwater sprinkling, until steady state was reached, (2) the following 35 hour period during which, in addition to the sprinkling, salt water was injected in two boreholes at a depth of 1m (unsaturated zone). The salt water injections were separated by 17 hours, and monitored until 14 hours after sprinkling stopped. During the first interval all changes in the subsurface resistivity are caused by changes in the water saturation and the temperature of the fluid, whereas in the second interval they are mainly due to changes in salt concentration of the pore fluid. Supplementary measurements of water table elevation and fluid electric conductivity were made in several boreholes. To image the subsurface resistivity changes, we inverted the ratios of time-lapse resistances to their background (pre-sprinkling) values. The sprinkling during time interval 1 allowed us to examine near-surface infiltration. Even from the first time window, the emergence of a shallow wetting front could be observed in the inverted depth sections as a decrease in bulk resistivity. Both salt water plumes during interval 2 were found to move laterally as well as vertically through the soil into a zone of fissured Flysch. Below the water table, the plume could be tracked further as a weaker ERT signal, which shows a flow component parallel to the water table in the downslope direction where it eventually breaks the surface. 3D ERT monitoring has proven to be a powerful tool to monitor water sprinkling and injection experiments. Due to its advantageous ability to resolve changes, both in time and in space, it captured most of the soil moisture and flow dynamics. Processes, such as infiltration and drainage, which are important for the understanding of runoff formation, could be readily visualized.

  19. Proceedings of the 8th Precise Time and Time Interval (PTTI) Applications and Planning Meeting

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Proceedings contain the papers presented at the Eight Annual Precise Time and Tme Interval PTTI Applications and Planning Meeting. The edited record of the discussions following the papers and the panel discussions are also included. This meeting provided a forum for the exchange of information on precise time and frequency technology among members of the scientific community and persons with program applications. The 282 registered attendees came from various U.S. Government agencies, private industry, universities and a number of foreign countries were represented. In this meeting, papers were presented that emphasized: (1) definitions and international regulations of precise time sources and users, (2) the scientific foundations of Hydrogen Maser standards, the current developments in this field and the application experience, and (3) how to measure the stability performance properties of precise standards. As in the previous meetings, update and new papers were presented on system applications with past, present and future requirements identified.

  20. Cascaded processing in written compound word production

    PubMed Central

    Bertram, Raymond; Tønnessen, Finn Egil; Strömqvist, Sven; Hyönä, Jukka; Niemi, Pekka

    2015-01-01

    In this study we investigated the intricate interplay between central linguistic processing and peripheral motor processes during typewriting. Participants had to typewrite two-constituent (noun-noun) Finnish compounds in response to picture presentation while their typing behavior was registered. As dependent measures we used writing onset time to assess what processes were completed before writing and inter-key intervals to assess what processes were going on during writing. It was found that writing onset time was determined by whole word frequency rather than constituent frequencies, indicating that compound words are retrieved as whole orthographic units before writing is initiated. In addition, we found that the length of the first syllable also affects writing onset time, indicating that the first syllable is fully prepared before writing commences. The inter-key interval results showed that linguistic planning is not fully ready before writing, but cascades into the motor execution phase. More specifically, inter-key intervals were largest at syllable and morpheme boundaries, supporting the view that additional linguistic planning takes place at these boundaries. Bigram and trigram frequency also affected inter-key intervals with shorter intervals corresponding to higher frequencies. This can be explained by stronger memory traces for frequently co-occurring letter sequences in the motor memory for typewriting. These frequency effects were even larger in the second than in the first constituent, indicating that low-level motor memory starts to become more important during the course of writing compound words. We discuss our results in the light of current models of morphological processing and written word production. PMID:25954182

  1. Cascaded processing in written compound word production.

    PubMed

    Bertram, Raymond; Tønnessen, Finn Egil; Strömqvist, Sven; Hyönä, Jukka; Niemi, Pekka

    2015-01-01

    In this study we investigated the intricate interplay between central linguistic processing and peripheral motor processes during typewriting. Participants had to typewrite two-constituent (noun-noun) Finnish compounds in response to picture presentation while their typing behavior was registered. As dependent measures we used writing onset time to assess what processes were completed before writing and inter-key intervals to assess what processes were going on during writing. It was found that writing onset time was determined by whole word frequency rather than constituent frequencies, indicating that compound words are retrieved as whole orthographic units before writing is initiated. In addition, we found that the length of the first syllable also affects writing onset time, indicating that the first syllable is fully prepared before writing commences. The inter-key interval results showed that linguistic planning is not fully ready before writing, but cascades into the motor execution phase. More specifically, inter-key intervals were largest at syllable and morpheme boundaries, supporting the view that additional linguistic planning takes place at these boundaries. Bigram and trigram frequency also affected inter-key intervals with shorter intervals corresponding to higher frequencies. This can be explained by stronger memory traces for frequently co-occurring letter sequences in the motor memory for typewriting. These frequency effects were even larger in the second than in the first constituent, indicating that low-level motor memory starts to become more important during the course of writing compound words. We discuss our results in the light of current models of morphological processing and written word production.

  2. Not All Prehospital Time is Equal: Influence of Scene Time on Mortality

    PubMed Central

    Brown, Joshua B.; Rosengart, Matthew R.; Forsythe, Raquel M.; Reynolds, Benjamin R.; Gestring, Mark L.; Hallinan, William M.; Peitzman, Andrew B.; Billiar, Timothy R.; Sperry, Jason L.

    2016-01-01

    Background Trauma is time-sensitive and minimizing prehospital (PH) time is appealing. However, most studies have not linked increasing PH time with worse outcomes, as raw PH times are highly variable. It is unclear whether specific PH time patterns affect outcomes. Our objective was to evaluate the association of PH time interval distribution with mortality. Methods Patients transported by EMS in the Pennsylvania trauma registry 2000-2013 with total prehospital time (TPT)≥20min were included. TPT was divided into three PH time intervals: response, scene, and transport time. The number of minutes in each PH time interval was divided by TPT to determine the relative proportion each interval contributed to TPT. A prolonged interval was defined as any one PH interval contributing ≥50% of TPT. Patients were classified by prolonged PH interval or no prolonged PH interval (all intervals<50% of TPT). Patients were matched for TPT and conditional logistic regression determined the association of mortality with PH time pattern, controlling for confounders. PH interventions were explored as potential mediators, and prehospital triage criteria used identify patients with time-sensitive injuries. Results There were 164,471 patients included. Patients with prolonged scene time had increased odds of mortality (OR 1.21; 95%CI 1.02–1.44, p=0.03). Prolonged response, transport, and no prolonged interval were not associated with mortality. When adjusting for mediators including extrication and PH intubation, prolonged scene time was no longer associated with mortality (OR 1.06; 0.90–1.25, p=0.50). Together these factors mediated 61% of the effect between prolonged scene time and mortality. Mortality remained associated with prolonged scene time in patients with hypotension, penetrating injury, and flail chest. Conclusions Prolonged scene time is associated with increased mortality. PH interventions partially mediate this association. Further study should evaluate whether these interventions drive increased mortality because they prolong scene time or by another mechanism, as reducing scene time may be a target for intervention. Level of Evidence IV, prognostic study PMID:26886000

  3. Continuous Blood Pressure Monitoring in Daily Life

    NASA Astrophysics Data System (ADS)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  4. Timing in Trace Conditioning of the Nictitating Membrane Response of the Rabbit ("Oryctolagus Cuniculus"): Scalar, Nonscalar, and Adaptive Features

    ERIC Educational Resources Information Center

    Kehoe, E. James; Ludvig, Elliot A.; Sutton, Richard S.

    2010-01-01

    Using interstimulus intervals (ISIs) of 125, 250, and 500 msec in trace conditioning of the rabbit nictitating membrane response, the offset times and durations of conditioned responses (CRs) were collected along with onset and peak latencies. All measures were proportional to the ISI, but only onset and peak latencies conformed to the criterion…

  5. Global Ionosphere Perturbations Monitored by the Worldwide GPS Network

    NASA Technical Reports Server (NTRS)

    Ho, C. M.; Manucci, A. T.; Lindqwister, U. J.; Pi, X.

    1996-01-01

    For the first time, measurements from the Global Positioning System (GPS) worldwide network are employed to study the global ionospheric total electron content(TEC) changes during a magnetic storm (November 26, 1994). These measurements are obtained from more than 60 world-wide GPS stations which continuously receive dual-frequency signals. Based on the delays of the signals, we have generated high resolution global ionospheric maps (GIM) of TEC at 15 minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that significant TEC increases (the positive effect ) are the major feature in the winter hemisphere during this storm (the maximum percent change relative to quiet times is about 150 percent).

  6. Setting the Revisit Interval in Primary Care

    PubMed Central

    Schwartz, Lisa M; Woloshin, Steven; Wasson, John H; Renfrew, Roger A; Welch, H Gilbert

    1999-01-01

    OBJECTIVE Although longitudinal care constitutes the bulk of primary care, physicians receive little guidance on the fundamental question of how to time follow-up visits. We sought to identify important predictors of the revisit interval and to describe the variability in how physicians set these intervals when caring for patients with common medical conditions. DESIGN Cross-sectional survey of physicians performed at the end of office visits for consecutive patients with hypertension, angina, diabetes, or musculoskeletal pain. PARTICIPANTS/SETTING One hundred sixty-four patients under the care of 11 primary care physicians in the Dartmouth Primary Care Cooperative Research Network. MEASUREMENTS The main outcome measures were the variability in mean revisit intervals across physicians and the proportion of explained variance by potential determinants of revisit intervals. We assessed the relation between the revisit interval (dependent variable) and three groups of independent variables, patient characteristics (e.g., age, physician perception of patient health), identification of individual physician, and physician characterization of the visit (e.g., routine visit, visit requiring a change in management, or visit occurring on a “hectic” day), using multiple regression that accounted for the natural grouping of patients within physician. MAIN RESULTS Revisit intervals ranged from 1 week to over 1 year. The most common intervals were 12 and 16 weeks. Physicians’ perception of fair-poor health status and visits involving a change in management were most strongly related to shorter revisit intervals. In multivariate analyses, patient characteristics explained about 18% of the variance in revisit intervals, and adding identification of the individual provider doubled the explained variance to about 40%. Physician characterization of the visit increased explained variance to 57%. The average revisit interval adjusted for patient characteristics for each of the 11 physicians varied from 4 to 20 weeks. Although all physicians lengthened revisit intervals for routine visits and shortened them when changing management, the relative ranking of mean revisit intervals for each physician changed little for different visit characterizations—some physicians were consistently long and others were consistently short. CONCLUSION Physicians vary widely in their recommendations for office revisits. Patient factors accounted for only a small part of this variation. Although physicians responded to visits in predictable ways, each physician appeared to have a unique set point for the length of the revisits interval. PMID:10203635

  7. Measuring Skew in Average Surface Roughness as a Function of Surface Preparation

    NASA Technical Reports Server (NTRS)

    Stahl, Mark T.

    2015-01-01

    Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces grinding saving both time and money and allows the science requirements to be better defined. In this study various materials are polished from a fine grind to a fine polish. Each sample's RMS surface roughness is measured at 81 locations in a 9x9 square grid using a Zygo white light interferometer at regular intervals during the polishing process. Each data set is fit with various standard distributions and tested for goodness of fit. We show that the skew in the RMS data changes as a function of polishing time.

  8. Interval Timing Accuracy and Scalar Timing in C57BL/6 Mice

    PubMed Central

    Buhusi, Catalin V.; Aziz, Dyana; Winslow, David; Carter, Rickey E.; Swearingen, Joshua E.; Buhusi, Mona C.

    2010-01-01

    In many species, interval timing behavior is accurate—appropriate estimated durations—and scalar—errors vary linearly with estimated durations. While accuracy has been previously examined, scalar timing has not been yet clearly demonstrated in house mice (Mus musculus), raising concerns about mouse models of human disease. We estimated timing accuracy and precision in C57BL/6 mice, the most used background strain for genetic models of human disease, in a peak-interval procedure with multiple intervals. Both when timing two intervals (Experiment 1) or three intervals (Experiment 2), C57BL/6 mice demonstrated varying degrees of timing accuracy. Importantly, both at individual and group level, their precision varied linearly with the subjective estimated duration. Further evidence for scalar timing was obtained using an intraclass correlation statistic. This is the first report of consistent, reliable scalar timing in a sizable sample of house mice, thus validating the PI procedure as a valuable technique, the intraclass correlation statistic as a powerful test of the scalar property, and the C57BL/6 strain as a suitable background for behavioral investigations of genetically engineered mice modeling disorders of interval timing. PMID:19824777

  9. Measuring happiness in individuals with profound multiple disabilities.

    PubMed

    Darling, Joseph A; Circo, Deborah K

    2015-12-01

    This quantitative study assessed whether presentation of preferred items and activities during multiple periods of the day (and over multiple days) increased indices of happiness (over time/sustained) in individuals with PMD. A multiple baseline design across participants was utilized to measure changes in indices of happiness of the participants. Participants were recruited from an adult day activity program specializing in providing assistance to individuals with disabilities. For Mary, baseline indices of happiness were 26.67% of intervals, increasing 6.76% during intervention to 33.43%. For Caleb, baseline indices of happiness were 20.84% of intervals, increasing 6.34% during intervention to 27.18%. For Mark, baseline indices of happiness were 40.00% of intervals, increasing 12.75% during intervention to 52.75%. Overall interobserver agreement was 82.8%, with interobserver agreement observations occurring during 63.04% of the observations. The results of the investigation demonstrated that presenting preferred items and activities increased the indices of happiness compared to baseline rates of indices of happiness. Results may have been more robust if the participants were assessed for overall responsiveness patterns prior to the initiation of measurement of indices of happiness. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Characterizing the graded structure of false killer whale (Pseudorca crassidens) vocalizations.

    PubMed

    Murray, S O; Mercado, E; Roitblat, H L

    1998-09-01

    The vocalizations from two, captive false killer whales (Pseudorca crassidens) were analyzed. The structure of the vocalizations was best modeled as lying along a continuum with trains of discrete, exponentially damped sinusoidal pulses at one end and continuous sinusoidal signals at the other end. Pulse trains were graded as a function of the interval between pulses where the minimum interval between pulses could be zero milliseconds. The transition from a pulse train with no inter-pulse interval to a whistle could be modeled by gradations in the degree of damping. There were many examples of vocalizations that were gradually modulated from pulse trains to whistles. There were also vocalizations that showed rapid shifts in signal type--for example, switching immediately from a whistle to a pulse train. These data have implications when considering both the possible function(s) of the vocalizations and the potential sound production mechanism(s). A short-time duty cycle measure was developed to characterize the graded structure of the vocalizations. A random sample of 500 vocalizations was characterized by combining the duty cycle measure with peak frequency measurements. The analysis method proved to be an effective metric for describing the graded structure of false killer whale vocalizations.

  11. Quantum stopwatch: how to store time in a quantum memory.

    PubMed

    Yang, Yuxiang; Chiribella, Giulio; Hayashi, Masahito

    2018-05-01

    Quantum mechanics imposes a fundamental trade-off between the accuracy of time measurements and the size of the systems used as clocks. When the measurements of different time intervals are combined, the errors due to the finite clock size accumulate, resulting in an overall inaccuracy that grows with the complexity of the set-up. Here, we introduce a method that, in principle, eludes the accumulation of errors by coherently transferring information from a quantum clock to a quantum memory of the smallest possible size. Our method could be used to measure the total duration of a sequence of events with enhanced accuracy, and to reduce the amount of quantum communication needed to stabilize clocks in a quantum network.

  12. Neutron coincidence counting based on time interval analysis with one- and two-dimensional Rossi-alpha distributions: an application for passive neutron waste assay

    NASA Astrophysics Data System (ADS)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R.

    1996-02-01

    Neutron coincidence counting is commonly used for the non-destructive assay of plutonium bearing waste or for safeguards verification measurements. A major drawback of conventional coincidence counting is related to the fact that a valid calibration is needed to convert a neutron coincidence count rate to a 240Pu equivalent mass ( 240Pu eq). In waste assay, calibrations are made for representative waste matrices and source distributions. The actual waste however may have quite different matrices and source distributions compared to the calibration samples. This often results in a bias of the assay result. This paper presents a new neutron multiplicity sensitive coincidence counting technique including an auto-calibration of the neutron detection efficiency. The coincidence counting principle is based on the recording of one- and two-dimensional Rossi-alpha distributions triggered respectively by pulse pairs and by pulse triplets. Rossi-alpha distributions allow an easy discrimination between real and accidental coincidences and are aimed at being measured by a PC-based fast time interval analyser. The Rossi-alpha distributions can be easily expressed in terms of a limited number of factorial moments of the neutron multiplicity distributions. The presented technique allows an unbiased measurement of the 240Pu eq mass. The presented theory—which will be indicated as Time Interval Analysis (TIA)—is complementary to Time Correlation Analysis (TCA) theories which were developed in the past, but is from the theoretical point of view much simpler and allows a straightforward calculation of deadtime corrections and error propagation. Analytical expressions are derived for the Rossi-alpha distributions as a function of the factorial moments of the efficiency dependent multiplicity distributions. The validity of the proposed theory is demonstrated and verified via Monte Carlo simulations of pulse trains and the subsequent analysis of the simulated data.

  13. The Effect of Prerequisite Pharmacodynamics Course Timing on Student Performance in Pharmacotherapy Courses.

    PubMed

    Kelsch, Michael P; Sylvester, Robert K

    2016-08-25

    Objective. To evaluate the impact that decreasing the time from 12 to three months between prerequisite pharmacodynamics courses and their corresponding pharmacotherapy courses had on overall student performance in the pharmacotherapy courses measured by course examination scores. Methods. Two cohorts of second-professional year (P2) and third professional year (P3) classes, respectively, following different curriculum plans, simultaneously took two pharmacotherapy courses (infectious disease and neoplastic disease). Admission data (age, gender, prior bachelor's degree status, grade point average (GPA), Pharmacy College Admission Test (PCAT) score, and interview score) were collected to establish baseline characteristics between the two cohorts. Examination scores in the corresponding prerequisite pharmacodynamics and pharmacotherapy courses were also collected. The variable was the difference in time each cohort experienced between the prerequisite pharmacodynamics courses and the subsequent pharmacotherapy courses. Results. No difference was found in baseline admission characteristics between the two cohorts, except for increased average age, which favored the P2 cohort. In the infectious disease pharmacotherapy course, the P3 cohort performed better than the P2 cohort as measured by average examination scores. In the neoplastic disease pharmacotherapy course, the P3 cohort also achieved significant higher average examination scores than the P2 cohort. The P3 cohort achieved higher overall scores than the P2 cohort in both courses despite a longer interval between the applicable pharmacodynamic and pharmacotherapy courses (12 months vs 3 months, respectively). Conclusion. Shortening the time interval from 12 months to three months between prerequisite and requisite courses did not result in improved, or even equivalent, academic performance relative to the P2 cohort that had only a 3-month interval between courses. Placing like content closer together, as the only intervention, is not enough to ensure improved student performance measured by examination scores in corresponding requisite courses.

  14. The Effect of Prerequisite Pharmacodynamics Course Timing on Student Performance in Pharmacotherapy Courses

    PubMed Central

    Sylvester, Robert K.

    2016-01-01

    Objective. To evaluate the impact that decreasing the time from 12 to three months between prerequisite pharmacodynamics courses and their corresponding pharmacotherapy courses had on overall student performance in the pharmacotherapy courses measured by course examination scores. Methods. Two cohorts of second-professional year (P2) and third professional year (P3) classes, respectively, following different curriculum plans, simultaneously took two pharmacotherapy courses (infectious disease and neoplastic disease). Admission data (age, gender, prior bachelor’s degree status, grade point average (GPA), Pharmacy College Admission Test (PCAT) score, and interview score) were collected to establish baseline characteristics between the two cohorts. Examination scores in the corresponding prerequisite pharmacodynamics and pharmacotherapy courses were also collected. The variable was the difference in time each cohort experienced between the prerequisite pharmacodynamics courses and the subsequent pharmacotherapy courses. Results. No difference was found in baseline admission characteristics between the two cohorts, except for increased average age, which favored the P2 cohort. In the infectious disease pharmacotherapy course, the P3 cohort performed better than the P2 cohort as measured by average examination scores. In the neoplastic disease pharmacotherapy course, the P3 cohort also achieved significant higher average examination scores than the P2 cohort. The P3 cohort achieved higher overall scores than the P2 cohort in both courses despite a longer interval between the applicable pharmacodynamic and pharmacotherapy courses (12 months vs 3 months, respectively). Conclusion. Shortening the time interval from 12 months to three months between prerequisite and requisite courses did not result in improved, or even equivalent, academic performance relative to the P2 cohort that had only a 3-month interval between courses. Placing like content closer together, as the only intervention, is not enough to ensure improved student performance measured by examination scores in corresponding requisite courses. PMID:27667836

  15. Pulse rate variability compared with Heart Rate Variability in children with and without sleep disordered breathing.

    PubMed

    Dehkordi, Parastoo; Garde, Ainara; Karlen, Walter; Wensley, David; Ansermino, J Mark; Dumont, Guy A

    2013-01-01

    Heart Rate Variability (HRV), the variation of time intervals between heartbeats, is one of the most promising and widely used quantitative markers of autonomic activity. Traditionally, HRV is measured as the series of instantaneous cycle intervals obtained from the electrocardiogram (ECG). In this study, we investigated the estimation of variation in heart rate from a photoplethysmography (PPG) signal, called pulse rate variability (PRV), and assessed its accuracy as an estimate of HRV in children with and without sleep disordered breathing (SDB). We recorded raw PPGs from 72 children using the Phone Oximeter, an oximeter connected to a mobile phone. Full polysomnography including ECG was simultaneously recorded for each subject. We used correlation and Bland-Altman analysis for comparing the parameters of HRV and PRV between two groups of children. Significant correlation (r > 0.90, p < 0.05) and close agreement were found between HRV and PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). However Bland-Altman analysis showed a large divergence for LF/HF ratio parameter. In addition, children with SDB had depressed SDNN and RMSSD and elevated LF/HF in comparison to children without SDB. In conclusion, PRV provides the accurate estimate of HRV in time domain analysis but does not reflect precise estimation for parameters in frequency domain.

  16. VARIABLE TIME-INTERVAL GENERATOR

    DOEpatents

    Gross, J.E.

    1959-10-31

    This patent relates to a pulse generator and more particularly to a time interval generator wherein the time interval between pulses is precisely determined. The variable time generator comprises two oscillators with one having a variable frequency output and the other a fixed frequency output. A frequency divider is connected to the variable oscillator for dividing its frequency by a selected factor and a counter is used for counting the periods of the fixed oscillator occurring during a cycle of the divided frequency of the variable oscillator. This defines the period of the variable oscillator in terms of that of the fixed oscillator. A circuit is provided for selecting as a time interval a predetermined number of periods of the variable oscillator. The output of the generator consists of a first pulse produced by a trigger circuit at the start of the time interval and a second pulse marking the end of the time interval produced by the same trigger circuit.

  17. Design and field tests of an access-tube soil water sensor

    USDA-ARS?s Scientific Manuscript database

    Accurate soil profile water content monitoring at multiple depths until now, has been possible only using the neutron probe (NP), but with great effort and at infrequent time intervals. Despite the existence of several electromagnetic sensor systems for profile water content measurements, accuracy ...

  18. Is physical activity differentially associated with different types of sedentary pursuits?

    PubMed

    Feldman, Debbie Ehrmann; Barnett, Tracie; Shrier, Ian; Rossignol, Michel; Abenhaim, Lucien

    2003-08-01

    To determine whether there is a relationship between the time adolescents spend in physical activity and time they spend in different sedentary pursuits: watching television, playing video games, working on computers, doing homework, and reading, taking into account the effect of part-time work on students' residual time. Cross-sectional cohort design. Seven hundred forty-three high school students from 2 inner-city public schools and 1 private school. Students completed a self-administered questionnaire that addressed time spent in physical activity, time spent in sedentary pursuits, musculoskeletal pain, and psychosocial issues and were also measured for height and weight. Main Outcome Measure Level of physical activity (low, moderate, high). There were more girls than boys in the low and moderate physical activity groups and more boys than girls in the high activity group. Ordinal logistic regression showed that increased time spent in "productive sedentary behavior" (reading or doing homework and working on computers) was associated with increased physical activity (odds ratio, 1.7; 95% confidence interval, 1.2-2.4), as was time spent working (odds ratio, 1.3; 95% confidence interval, 1.2-1.4). Time spent watching television and playing video games was not associated with decreased physical activity. Physical activity was not inversely associated with watching television or playing video games, but was positively associated with productive sedentary behavior and part-time work. Some students appear capable of managing their time better than others. Future studies should explore the ability of students to manage their time and also determine what characteristics are conducive to better time management.

  19. Using complexity metrics with R-R intervals and BPM heart rate measures.

    PubMed

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics-fractal (DFA) and recurrence (RQA) analyses-reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, "oversampled" BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics.

  20. Using complexity metrics with R-R intervals and BPM heart rate measures

    PubMed Central

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian; Jegindø, Else-Marie

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically on variability of the data, different choices regarding the kind of measures can have a substantial impact on the results. In this article we compare linear and non-linear statistics on two prominent types of heart beat data, beat-to-beat intervals (R-R interval) and beats-per-min (BPM). As a proof-of-concept, we employ a simple rest-exercise-rest task and show that non-linear statistics—fractal (DFA) and recurrence (RQA) analyses—reveal information about heart beat activity above and beyond the simple level of heart rate. Non-linear statistics unveil sustained post-exercise effects on heart rate dynamics, but their power to do so critically depends on the type data that is employed: While R-R intervals are very susceptible to non-linear analyses, the success of non-linear methods for BPM data critically depends on their construction. Generally, “oversampled” BPM time-series can be recommended as they retain most of the information about non-linear aspects of heart beat dynamics. PMID:23964244

  1. Hospital factors impact variation in emergency department length of stay more than physician factors.

    PubMed

    Krall, Scott P; Cornelius, Angela P; Addison, J Bruce

    2014-03-01

    To analyze the correlation between the many different emergency department (ED) treatment metric intervals and determine if the metrics directly impacted by the physician correlate to the "door to room" interval in an ED (interval determined by ED bed availability). Our null hypothesis was that the cause of the variation in delay to receiving a room was multifactorial and does not correlate to any one metric interval. We collected daily interval averages from the ED information system, Meditech©. Patient flow metrics were collected on a 24-hour basis. We analyzed the relationship between the time intervals that make up an ED visit and the "arrival to room" interval using simple correlation (Pearson Correlation coefficients). Summary statistics of industry standard metrics were also done by dividing the intervals into 2 groups, based on the average ED length of stay (LOS) from the National Hospital Ambulatory Medical Care Survey: 2008 Emergency Department Summary. Simple correlation analysis showed that the doctor-to-discharge time interval had no correlation to the interval of "door to room (waiting room time)", correlation coefficient (CC) (CC=0.000, p=0.96). "Room to doctor" had a low correlation to "door to room" CC=0.143, while "decision to admitted patients departing the ED time" had a moderate correlation of 0.29 (p <0.001). "New arrivals" (daily patient census) had a strong correlation to longer "door to room" times, 0.657, p<0.001. The "door to discharge" times had a very strong correlation CC=0.804 (p<0.001), to the extended "door to room" time. Physician-dependent intervals had minimal correlation to the variation in arrival to room time. The "door to room" interval was a significant component to the variation in "door to discharge" i.e. LOS. The hospital-influenced "admit decision to hospital bed" i.e. hospital inpatient capacity, interval had a correlation to delayed "door to room" time. The other major factor affecting department bed availability was the "total patients per day." The correlation to the increasing "door to room" time also reflects the effect of availability of ED resources (beds) on the patient evaluation time. The time that it took for a patient to receive a room appeared more dependent on the system resources, for example, beds in the ED, as well as in the hospital, than on the physician.

  2. Interpreting Results from the Standardized UXO Test Sites

    DTIC Science & Technology

    2007-01-01

    Detector Focusing Lens Cs Cell Split Polarizer Filter Collimating Lens Cs Lamp RF Coil Tiffany Mount H1 Coil Light rays Figure II-1. G-858 Cesium...conductive earth typically decay at a more rapid rate than the currents in metallic objects. Measurements are made in discrete “time gates,” or...time intervals, following the turnoff of the current pulse generated by the transmitter. The early time gates will detect both small and large metallic

  3. Effect of Maternal–Child Home Visitation on Pregnancy Spacing for First-Time Latina Mothers

    PubMed Central

    Chesnokova, Arina; Matone, Meredith; Luan, Xianqun; Localio, A. Russell; Rubin, David M.

    2014-01-01

    Objectives. We examined the impact of a maternal–child home visitation program on birth spacing for first-time Latina mothers, focusing on adolescents and women who identified as Mexican or Puerto Rican. Methods. This was a retrospective cohort study. One thousand Latina women enrolled in the Pennsylvania Nurse–Family Partnership between January 1, 2003, and December 31, 2007, were matched to nonenrolled Latina women using propensity scores. The primary outcome was the time to second pregnancy that resulted in a live birth (interpregnancy interval). Proportional hazards models and bootstrap methods compared the time to event. Results. Home visitation was associated with a small decrease in the risk of a short interpregnancy interval (≤ 18 months) among Latina women (hazards ratio [HR] = 0.86; 95% confidence interval [CI] = 0.75, 0.99). This effect was driven by outcomes among younger adolescent women (HR = 0.80; 95% CI = 0.65, 0.96). There was also a trend toward significance for women of Mexican heritage (HR = 0.74; 95% CI = 0.49, 1.07), although this effect might be attributed to individual agency performance. Conclusions. Home visitation using the Nurse–Family Partnership model had measurable effects on birth spacing in Latina women. PMID:24354820

  4. Effect of maternal-child home visitation on pregnancy spacing for first-time Latina mothers.

    PubMed

    Yun, Katherine; Chesnokova, Arina; Matone, Meredith; Luan, Xianqun; Localio, A Russell; Rubin, David M

    2014-02-01

    We examined the impact of a maternal-child home visitation program on birth spacing for first-time Latina mothers, focusing on adolescents and women who identified as Mexican or Puerto Rican. This was a retrospective cohort study. One thousand Latina women enrolled in the Pennsylvania Nurse-Family Partnership between January 1, 2003, and December 31, 2007, were matched to nonenrolled Latina women using propensity scores. The primary outcome was the time to second pregnancy that resulted in a live birth (interpregnancy interval). Proportional hazards models and bootstrap methods compared the time to event. Home visitation was associated with a small decrease in the risk of a short interpregnancy interval (≤ 18 months) among Latina women (hazards ratio [HR] = 0.86; 95% confidence interval [CI] = 0.75, 0.99). This effect was driven by outcomes among younger adolescent women (HR = 0.80; 95% CI = 0.65, 0.96). There was also a trend toward significance for women of Mexican heritage (HR = 0.74; 95% CI = 0.49, 1.07), although this effect might be attributed to individual agency performance. Home visitation using the Nurse-Family Partnership model had measurable effects on birth spacing in Latina women.

  5. Contraction frequency after administration of misoprostol in obese versus nonobese women.

    PubMed

    Stefely, Erin; Warshak, Carri R

    2018-04-30

    To examine impact of obesity on contraction frequency following misoprostol. Our hypothesis is that an increased volume of distribution reduces the bioavailability of misoprostol and may be an explanation for reduced efficacy. We examined the contraction frequency as a surrogate marker for bioavailability of misoprostol. We compared the rate of contractions at five time intervals in 313 subjects: prior to administration, and at four intervals post administration. We compared number of contractions in obese versus nonobese. As a planned secondary analysis, we then compared the rate of change in contractions per hour at four time intervals: a repeated measures analysis to compare the rate of change in contractions per hour over the 5-hour window controlling for race (White versus non-White) and parity (primiparous versus multiparous). General linear model and repeated measures analysis were conducted to report the parameter estimates, least square means, difference of least square means, and p values. Nonobese women presented with more contractions at baseline, 7 ± 5 versus 4 ± 5 c/h, p < .001. At all four time intervals after misoprostol administration obese women had fewer contractions per hour. The rate of change in contraction frequency after administration found obese women had a lower rate of increase in contraction frequency over the course of all four hours. We found a least squares means estimate (c/h): first hour (-0.87), p = .08, second hour (-2.43), p = .01, third hour (-1.80), p = .96, and fourth hour (-2.98), p = .007. Obese women have a lower rate of contractions per hour at baseline and at four intervals after misoprostol administration. In addition, the rate of change in the increase in contractions/hour also was reduced in obese women versus nonobese women. This suggests a lower bioavailability of misoprostol in women with a larger volume of distribution which would likely impact the efficacy of misoprostol in obese women when given the same dose of misoprostol. It is unknown if higher misoprostol dosing would increase efficacy of misoprostol in obese women.

  6. Studies on time of death estimation in the early post mortem period -- application of a method based on eyeball temperature measurement to human bodies.

    PubMed

    Kaliszan, Michał

    2013-09-01

    This paper presents a verification of the thermodynamic model allowing an estimation of the time of death (TOD) by calculating the post mortem interval (PMI) based on a single eyeball temperature measurement at the death scene. The study was performed on 30 cases with known PMI, ranging from 1h 35min to 5h 15min, using pin probes connected to a high precision electronic thermometer (Dostmann-electronic). The measured eye temperatures ranged from 20.2 to 33.1°C. Rectal temperature was measured at the same time and ranged from 32.8 to 37.4°C. Ambient temperatures which ranged from -1 to 24°C, environmental conditions (still air to light wind) and the amount of hair on the head were also recorded every time. PMI was calculated using a formula based on Newton's law of cooling, previously derived and successfully tested in comprehensive studies on pigs and a few human cases. Thanks to both the significantly faster post mortem decrease of eye temperature and a residual or nonexistent plateau effect in the eye, as well as practically no influence of body mass, TOD in the human death cases could be estimated with good accuracy. The highest TOD estimation error during the post mortem intervals up to around 5h was 1h 16min, 1h 14min and 1h 03min, respectively in three cases among 30, while for the remaining 27 cases it was not more than 47min. The mean error for all 30 cases was ±31min. All that indicates that the proposed method is of quite good precision in the early post mortem period, with an accuracy of ±1h for a 95% confidence interval. On the basis of the presented method, TOD can be also calculated at the death scene with the use of a proposed portable electronic device (TOD-meter). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer.

    PubMed

    Pandia, Keya; Inan, Omer T; Kovacs, Gregory T A; Giovangrandi, Laurent

    2012-10-01

    Seismocardiography (SCG) is a non-invasive measurement of the vibrations of the chest caused by the heartbeat. SCG signals can be measured using a miniature accelerometer attached to the chest, and are thus well-suited for unobtrusive and long-term patient monitoring. Additionally, SCG contains information relating to both cardiovascular and respiratory systems. In this work, algorithms were developed for extracting three respiration-dependent features of the SCG signal: intensity modulation, timing interval changes within each heartbeat, and timing interval changes between successive heartbeats. Simultaneously with a reference respiration belt, SCG signals were measured from 20 healthy subjects and a respiration rate was estimated using each of the three SCG features and the reference signal. The agreement between each of the three accelerometer-derived respiration rate measurements was computed with respect to the respiration rate derived from the reference respiration belt. The respiration rate obtained from the intensity modulation in the SCG signal was found to be in closest agreement with the respiration rate obtained from the reference respiration belt: the bias was found to be 0.06 breaths per minute with a 95% confidence interval of -0.99 to 1.11 breaths per minute. The limits of agreement between the respiration rates estimated using SCG (intensity modulation) and the reference were within the clinically relevant ranges given in existing literature, demonstrating that SCG could be used for both cardiovascular and respiratory monitoring. Furthermore, phases of each of the three SCG parameters were investigated at four instances of a respiration cycle-start inspiration, peak inspiration, start expiration, and peak expiration-and during breath hold (apnea). The phases of the three SCG parameters observed during the respiration cycle were congruent with existing literature and physiologically expected trends.

  8. Comparison of automated measurements of electrocardiographic intervals and durations by computer-based algorithms of digital electrocardiographs.

    PubMed

    Kligfield, Paul; Badilini, Fabio; Rowlandson, Ian; Xue, Joel; Clark, Elaine; Devine, Brian; Macfarlane, Peter; de Bie, Johan; Mortara, David; Babaeizadeh, Saeed; Gregg, Richard; Helfenbein, Eric D; Green, Cynthia L

    2014-02-01

    Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs. Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium. Included were 3 groups based on expected QT interval and degree of repolarization abnormality, comprising 200 ECGs each from (1) placebo or baseline study period in normal subjects during thorough QT studies, (2) peak moxifloxacin effect in otherwise normal subjects during thorough QT studies, and (3) patients with genotyped variants of congenital long QT syndrome (LQTS). Differences of means between manufacturers were generally small in the normal and moxifloxacin subjects, but in the LQTS patients, differences of means ranged from 2.0 to 14.0 ms for QRS duration and from 0.8 to 18.1 ms for the QT interval. Mean absolute differences between algorithms were similar for QRS duration and QT intervals in the normal and in the moxifloxacin subjects (mean ≤6 ms) but were significantly larger in patients with LQTS. Small but statistically significant group differences in mean interval and duration measurements and means of individual absolute differences exist among automated algorithms of widely used, current generation digital electrocardiographs. Measurement differences, including QRS duration and the QT interval, are greatest for the most abnormal ECGs. © 2014.

  9. The Anaesthetic-ECT Time Interval in Electroconvulsive Therapy Practice--Is It Time to Time?

    PubMed

    Gálvez, Verònica; Hadzi-Pavlovic, Dusan; Wark, Harry; Harper, Simon; Leyden, John; Loo, Colleen K

    2016-01-01

    Because most common intravenous anaesthetics used in ECT have anticonvulsant properties, their plasma-brain concentration at the time of seizure induction might affect seizure expression. The quality of ECT seizure expression has been repeatedly associated with efficacy outcomes. The time interval between the anaesthetic bolus injection and the ECT stimulus (anaesthetic-ECT time interval) will determine the anaesthetic plasma-brain concentration when the ECT stimulus is administered. The aim of this study was to examine the effect of the anaesthetic-ECT time interval on ECT seizure quality and duration. The anaesthetic-ECT time interval was recorded in 771 ECT sessions (84 patients). Right unilateral brief pulse ECT was applied. Anaesthesia given was propofol (1-2 mg/kg) and succinylcholine (0.5-1.0 mg/kg). Seizure quality indices (slow wave onset, amplitude, regularity, stereotypy and post-ictal suppression) and duration were rated through a structured rating scale by a single blinded trained rater. Linear Mixed Effects Models analysed the effect of the anaesthetic-ECT time interval on seizure quality indices, controlling for propofol dose (mg), ECT charge (mC), ECT session number, days between ECT, age (years), initial seizure threshold (mC) and concurrent medication. Longer anaesthetic-ECT time intervals lead to significantly higher quality seizures (p < 0.001 for amplitude, regularity, stereotypy and post-ictal suppression). These results suggest that the anaesthetic-ECT time interval is an important factor to consider in ECT practice. This time interval should be extended to as long as practically possible to facilitate the production of better quality seizures. Close collaboration between the anaesthetist and the psychiatrist is essential. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The effects of sampling frequency on the climate statistics of the European Centre for Medium-Range Weather Forecasts

    NASA Astrophysics Data System (ADS)

    Phillips, Thomas J.; Gates, W. Lawrence; Arpe, Klaus

    1992-12-01

    The effects of sampling frequency on the first- and second-moment statistics of selected European Centre for Medium-Range Weather Forecasts (ECMWF) model variables are investigated in a simulation of "perpetual July" with a diurnal cycle included and with surface and atmospheric fields saved at hourly intervals. The shortest characteristic time scales (as determined by the e-folding time of lagged autocorrelation functions) are those of ground heat fluxes and temperatures, precipitation and runoff, convective processes, cloud properties, and atmospheric vertical motion, while the longest time scales are exhibited by soil temperature and moisture, surface pressure, and atmospheric specific humidity, temperature, and wind. The time scales of surface heat and momentum fluxes and of convective processes are substantially shorter over land than over oceans. An appropriate sampling frequency for each model variable is obtained by comparing the estimates of first- and second-moment statistics determined at intervals ranging from 2 to 24 hours with the "best" estimates obtained from hourly sampling. Relatively accurate estimation of first- and second-moment climate statistics (10% errors in means, 20% errors in variances) can be achieved by sampling a model variable at intervals that usually are longer than the bandwidth of its time series but that often are shorter than its characteristic time scale. For the surface variables, sampling at intervals that are nonintegral divisors of a 24-hour day yields relatively more accurate time-mean statistics because of a reduction in errors associated with aliasing of the diurnal cycle and higher-frequency harmonics. The superior estimates of first-moment statistics are accompanied by inferior estimates of the variance of the daily means due to the presence of systematic biases, but these probably can be avoided by defining a different measure of low-frequency variability. Estimates of the intradiurnal variance of accumulated precipitation and surface runoff also are strongly impacted by the length of the storage interval. In light of these results, several alternative strategies for storage of the EMWF model variables are recommended.

  11. Ionospheric convection during the magnetic storm of 20-21 March 1991

    NASA Technical Reports Server (NTRS)

    Taylor, J. R.; Yeoman, T. K.; Lester, M.; Buonsanto, M. J.; Scali, J. L.; Ruohoniemi, J. M.; Kelly, J. D.

    1994-01-01

    We report on the response of high-latitude ionospheric convection during the magnetic storm of March 20-21 1990. IMP-8 measurements of solar wind plasma and interplanetary magnetic field (IMF), ionospheric convection flow measurements from the Wick and Goose Bay coherent radars, EISCAT, Millstone Hill and Sondrestorm incoherent radars and three digisondes at Millstone Hill, Goose Bay and Qaanaaq are presented. Two intervals of particular interest have been indentified. The first starts with a storm sudden commencement at 2243 UT on March 20 and includes the ionospheric activity in the following 7 h. The response time of the ionospheric convection to the southward tuning of the IMF in the dusk to midnight local times is found to be approximately half that measured in a similar study at comparable local times during more normal solar wind conditions. A subsequent reconfiguration of the nightside convection pattern was also observed, although it was not possible to distinguish between effects due to possible changes in B(sub y) and effects due to substorm activity. The second interval, 1200-2100 UT 21 March 1990, included a southward turning of the IMF which resulted in the B(sub z) component becoming -10 nT. The response time on the dayside to this change in the IMF at the magnetopause was approximately 15 min to 30 min which is a factor of approximately 2 greater than those previously measured at higher latitudes. A movement of the nightside flow reversal, possibly driven by current systems associated with the substorm expansion phases, was observed, implying that the nightside convection pattern can be dominated by substorm activity.

  12. On the Determination of Uncertainty and Limit of Detection in Label-Free Biosensors.

    PubMed

    Lavín, Álvaro; Vicente, Jesús de; Holgado, Miguel; Laguna, María F; Casquel, Rafael; Santamaría, Beatriz; Maigler, María Victoria; Hernández, Ana L; Ramírez, Yolanda

    2018-06-26

    A significant amount of noteworthy articles reviewing different label-free biosensors are being published in the last years. Most of the times, the comparison among the different biosensors is limited by the procedure used of calculating the limit of detection and the measurement uncertainty. This article clarifies and establishes a simple procedure to determine the calibration function and the uncertainty of the concentration measured at any point of the measuring interval of a generic label-free biosensor. The value of the limit of detection arises naturally from this model as the limit at which uncertainty tends when the concentration tends to zero. The need to provide additional information, such as the measurement interval and its linearity, among others, on the analytical systems and biosensor in addition to the detection limit is pointed out. Finally, the model is applied to curves that are typically obtained in immunoassays and a discussion is made on the application validity of the model and its limitations.

  13. Variability of reflectance measurements with sensor altitude and canopy type

    NASA Technical Reports Server (NTRS)

    Daughtry, C. S. T.; Vanderbilt, V. C.; Pollara, V. J.

    1981-01-01

    Data were acquired on canopies of mature corn planted in 76 cm rows, mature soybeans planted in 96 cm rows with 71 percent soil cover, and mature soybeans planed in 76 cm rows with 100 percent soil cover. A LANDSAT band radiometer with a 15 degree field of view was used at ten altitudes ranging from 0.2 m to 10 m above the canopy. At each altitude, measurements were taken at 15 cm intervals also a 2.0 m transect perpendicular to the crop row direction. Reflectance data were plotted as a function of altitude and horizontal position to verify that the variance of measurements at low altitudes was attributable to row effects which disappear at higher altitudes where the sensor integrate across several rows. The coefficient of variation of reflectance decreased exponentially as the sensor was elevated. Systematic sampling (at odd multiples of 0.5 times the row spacing interval) required fewer measurements than simple random sampling over row crop canopies.

  14. The Attentional Demand of Automobile Driving Revisited: Occlusion Distance as a Function of Task-Relevant Event Density in Realistic Driving Scenarios.

    PubMed

    Kujala, Tuomo; Mäkelä, Jakke; Kotilainen, Ilkka; Tokkonen, Timo

    2016-02-01

    We studied the utility of occlusion distance as a function of task-relevant event density in realistic traffic scenarios with self-controlled speed. The visual occlusion technique is an established method for assessing visual demands of driving. However, occlusion time is not a highly informative measure of environmental task-relevant event density in self-paced driving scenarios because it partials out the effects of changes in driving speed. Self-determined occlusion times and distances of 97 drivers with varying backgrounds were analyzed in driving scenarios simulating real Finnish suburban and highway traffic environments with self-determined vehicle speed. Occlusion distances varied systematically with the expected environmental demands of the manipulated driving scenarios whereas the distributions of occlusion times remained more static across the scenarios. Systematic individual differences in the preferred occlusion distances were observed. More experienced drivers achieved better lane-keeping accuracy than inexperienced drivers with similar occlusion distances; however, driving experience was unexpectedly not a major factor for the preferred occlusion distances. Occlusion distance seems to be an informative measure for assessing task-relevant event density in realistic traffic scenarios with self-controlled speed. Occlusion time measures the visual demand of driving as the task-relevant event rate in time intervals, whereas occlusion distance measures the experienced task-relevant event density in distance intervals. The findings can be utilized in context-aware distraction mitigation systems, human-automated vehicle interaction, road speed prediction and design, as well as in the testing of visual in-vehicle tasks for inappropriate in-vehicle glancing behaviors in any dynamic traffic scenario for which appropriate individual occlusion distances can be defined. © 2015, Human Factors and Ergonomics Society.

  15. Acute Kidney Injury Incidence in Noncritically Ill Hospitalized Children, Adolescents, and Young Adults: A Retrospective Observational Study

    PubMed Central

    McGregor, Tracy L.; Jones, Deborah P.; Wang, Li; Danciu, Ioana; Bridges, Brian C.; Fleming, Geoffrey M.; Shirey-Rice, Jana; Chen, Lixin; Byrne, Daniel W.; Van Driest, Sara L.

    2015-01-01

    Background Acute kidney injury (AKI) has been characterized in young high-risk inpatients, in whom AKI is frequent and associated with increased mortality, morbidity, and length of stay. The incidence of AKI among patients not requiring intensive care is unknown. Study Design Retrospective cohort study Setting & Participants 13,914 noncritical admissions during 2011–2012 at our tertiary referral pediatric hospital were evaluated. Patients <28 days or >21 years of age, or with chronic kidney disease (CKD), were excluded. Admissions with ≥2 serum creatinine measurements were evaluated. Factors Demographic features, laboratory measurements, medication exposures, and length of stay. Outcome AKI defined by increased serum creatinine in accordance with KDIGO (Kidney Disease: Improving Global Outcomes) criteria. Based on time of admission, time interval requirements were met in 97% of cases, but KDIGO time window criteria were not strictly enforced to allow implementation using clinically-obtained data. Results Two or more creatinine measurements (one baseline before or during admission, and a second during admission) in 2,374 of 13,914 (17%) patients allowed for AKI evaluation. A serum creatinine difference of ≥0.3 mg/dL or ≥1.5 times baseline was seen in 722 of 2,374 (30%) patients. A minimum of 5% of all noncritical inpatients without CKD in pediatric wards have an episode of AKI during routine hospital admission. Limitations Urine output, glomerular filtration rate, and time interval criteria for AKI were not applied secondary to study design and available data. The evaluated cohort was restricted to patients with ≥2 clinically obtained serum creatinine measurements, and baseline creatinine may have been measured after the AKI episode. Conclusions AKI occurs in at least 5% of all non-critically ill hospitalized children, adolescents, and young adults without known CKD. Physicians should increase their awareness of AKI and improve surveillance strategies with serum creatinine measurements in this population so that exacerbating factors such as nephrotoxic medication exposures may be modified as indicated. PMID:26319754

  16. Differences between measured and linearly interpolated synoptic variables over a 12-h period during AVE 4

    NASA Technical Reports Server (NTRS)

    Dupuis, L. R.; Scoggins, J. R.

    1979-01-01

    Results of analyses revealed that nonlinear changes or differences formed centers or systems, that were mesosynoptic in nature. These systems correlated well in space with upper level short waves, frontal zones, and radar observed convection, and were very systematic in time and space. Many of the centers of differences were well established in the vertical, extending up to the tropopause. Statistical analysis showed that on the average nonlinear changes were larger in convective areas than nonconvective regions. Errors often exceeding 100 percent were made by assuming variables to change linearly through a 12-h period in areas of thunderstorms, indicating that these nonlinear changes are important in the development of severe weather. Linear changes, however, accounted for more and more of an observed change as the time interval (within the 12-h interpolation period) increased, implying that the accuracy of linear interpolation increased over larger time intervals.

  17. The clinical evaluation of platelet-rich plasma on free gingival graft's donor site wound healing.

    PubMed

    Samani, Mahmoud Khosravi; Saberi, Bardia Vadiati; Ali Tabatabaei, S M; Moghadam, Mahdjoube Goldani

    2017-01-01

    It has been proved that platelet-rich plasma (PRP) can promote wound healing. In this way, PRP can be advantageous in periodontal plastic surgeries, free gingival graft (FGG) being one such surgery. In this randomized split-mouth controlled trial, 10 patients who needed bilateral FGG were selected, and two donor sites were randomly assigned to experience either natural healing or healing-assisted with PRP. The outcome was assessed based on the comparison of the extent of wound closure, Manchester scale, Landry healing scale, visual analog scale, and tissue thickness between the study groups at different time intervals. Repeated measurements of analysis of variance and paired t -test were used. Statistical significance was P ≤ 0.05. Significant differences between the study groups and also across different time intervals were seen in all parameters except for the changes in tissue thickness. PRP accelerates the healing process of wounds and reduces the healing time.

  18. Stand structure and growth of Abies magnifica responded to five thinning levels in northeastern California, USA

    Treesearch

    Jianwei Zhang; William W. Oliver

    2006-01-01

    A 60-year old red fir stand with 23,950 stems per ha was thinned to five stand densities. Thinning occurred in 1972, 1976, and 1980. Height, DBH, and crown characteristics were measured seven times at four- to seven-year intervals from 1972 to 2002. Tree rings were measured retrospectively to determine growth of individual years. Periodic annual increment (PAI) was...

  19. Accuracy of the Velotron ergometer and SRM power meter.

    PubMed

    Abbiss, C R; Quod, M J; Levin, G; Martin, D T; Laursen, P B

    2009-02-01

    The purpose of this study was to determine the accuracy of the Velotron cycle ergometer and the SRM power meter using a dynamic calibration rig over a range of exercise protocols commonly applied in laboratory settings. These trials included two sustained constant power trials (250 W and 414 W), two incremental power trials and three high-intensity interval power trials. To further compare the two systems, 15 subjects performed three dynamic 30 km performance time trials. The Velotron and SRM displayed accurate measurements of power during both constant power trials (<1% error). However, during high-intensity interval trials the Velotron and SRM were found to be less accurate (3.0%, CI=1.6-4.5% and -2.6%, CI=-3.2--2.0% error, respectively). During the dynamic 30 km time trials, power measured by the Velotron was 3.7+/-1.9% (CI=2.9-4.8%) greater than that measured by the SRM. In conclusion, the accuracy of the Velotron cycle ergometer and the SRM power meter appears to be dependent on the type of test being performed. Furthermore, as each power monitoring system measures power at various positions (i.e. bottom bracket vs. rear wheel), caution should be taken when comparing power across the two systems, particularly when power is variable.

  20. Astrochronology of the Pliensbachian-Toarcian transition in the Foum Tillicht section (central High Atlas, Morroco)

    NASA Astrophysics Data System (ADS)

    Martinez, Mathieu; Bodin, Stéphane; Krencker, François-Nicolas

    2015-04-01

    The Pliensbachian and Toarcian stages (Early Jurassic) are marked by a series of carbon cycle disturbances, major climatic changes and severe faunal turnovers. An accurate knowledge of the timing of the Pliensbachian-Toarcian age is a key for quantifying fluxes and rhythms of faunal and geochemical processes during these major environmental perturbations. Although many studies provided astrochronological frameworks of the Toarcian Stage and the Toarcian oceanic anoxic event, no precise time frame exists for the Pliensbachian-Toarcian transition, often condensed in the previously studied sections. Here, we provide an astrochronology of the Pliensbachian-Toarcian transition in the Foum Tillicht section (central High Atlas, Morocco). The section is composed of decimetric hemipelagic marl-limestone alternations accompanied by cyclic fluctuations in the δ13Cmicrite. In this section, the marl-limestone alternations reflect cyclic sea-level/climatic changes, which triggers rhythmic migrations of the surrounding carbonate platforms and modulates the amount of carbonate exported to the basin. The studied interval encompasses 142.15 m of the section, from the base of the series to a hiatus in the Early Toarcian, marked by an erosional surface. The Pliensbachian-Toarcian (P-To) Event, a negative excursion in carbonate δ13Cmicrite, is observed pro parte in this studied interval. δ13Cmicrite measurements were performed every ~2 m at the base of the section and every 0.20 m within the P-To Event interval. Spectral analyses were performed using the multi-taper method and the evolutive Fast Fourier Transform to get the accurate assessment of the main significant periods and their evolution throughout the studied interval. Two main cycles are observed in the series: the 405-kyr eccentricity cycles is observed throughout the series, while the obliquity cycles is observed within the P-To Event, in the most densely sampled interval. The studied interval covers a 3.6-Myr interval. The duration of the part of P-To Event covered in this analysis is assessed at 0.70 Myr. In addition, the interval from the base of the Toarcian to the first occurrence of the calcareous nannofossil C. superbus has a duration assessed from 0.47 to 0.55 Myr. This duration is significantly higher than most of assessments obtained by former cyclostratigraphy analyses, showing that previous studies underestimated the duration of this interval, often condensed in the Western Tethys. This study shows the potential of the Foum Tillicht section to provide a refined time frame of the Pliensbachian-Toarcian boundary, which could be integrated in the next Geological Time Scale.

  1. Heart rate variability in the individual fetus.

    PubMed

    Van Leeuwen, Peter; Cysarz, Dirk; Edelhäuser, Friedrich; Grönemeyer, Dietrich

    2013-11-01

    The change in fetal heart rate and its variability (HRV) during the course of gestation has been documented by numerous studies. The overall drop in heart rate and increase in fetal HRV is associated with fetal growth in general and with the increase in neural integration in particular. The increased complexity of the demands on the cardiovascular system leads to more variation in the temporal course of the heart rate. Most studies that document and interpret these changes are based on data acquired in groups of fetuses. The aim of this work was to investigate HRV within single fetuses. We acquired 213 5min fetal magnetocardiograms in 11 fetuses during the second and third trimesters (at least 10 data sets per fetus, median 17). From the magnetocardiograms we determined the fetal RR interval time series and calculated the standard deviation (SDNN), root mean square of successive differences (RMSSD), approximate entropy (ApEn) and temporal asymmetry (Irrev). For each subject and HRV measure, we performed regression analysis with respect to gestational age, alone and in combination with RR interval. The coefficient of determination R(2) was used to estimate goodness-of-fit. The coefficient of quartile dispersion (CQD) was used to compare the regression parameters for each HRV measure. Overall, the HRV measures increased with age and RR interval. The consistency of the HRV measures within the individual fetuses was greater than in the data pooled over all fetuses. The individual R(2) for the model including age and RR interval was best for ApEn (.79, .59-.94; median, 90% CI), followed by RMSSD (.71, .25-.88), SDNN (.55, .18-.90) and Irrev (.16, .01-.39). These values, except for Irrev, were higher than those calculated over all 213 data sets (R(2)=.65, .63, .35, .28, respectively). The slopes of the regressions of each individual's data were most consistent over all subjects for ApEn, followed by RMSSD and SDNN and Irrev. Interindividually, the time domain measures showed discrepancies and the within-fetus courses were more consistent than the course over all fetuses. On the other hand, the course of ApEn during gestation was not only very consistent within each fetus but also very similar between most of subjects. Complexity measures such as ApEn may thus more consistently reflect prenatal developmental factors influencing cardiovascular regulation. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Intravenous parecoxib and continuous femoral block for postoperative analgesia after total knee arthroplasty. A randomized, double-blind, prospective trial.

    PubMed

    Sarridou, Despoina G; Chalmouki, Georgia; Braoudaki, Maria; Koutsoupaki, Anna; Mela, Argiro; Vadalouka, Athina

    2015-01-01

    Up until now, the optimal strategy for postoperative pain management after total knee arthroplasty (TKA) remains to be elucidated. The current investigation aimed to examine the analgesic efficacy and the opioid sparing effects of intravenous parecoxib in combination with continuous femoral blockade. Randomized, double-blind, prospective trial. University hospital in the United Kingdom. In total, 90 patients underwent TKA under subarachnoid anesthesia and received continuous femoral block initially as a bolus with 20 mL of ropivacaine 0.75%. Infusion of 0.2% on 10 mL/h followed. Patients were randomized into 2 groups. Group D and Group P received parecoxib and placebo, respectively at 12 hour time intervals. Visual analog scale (VAS) pain scores were obtained at different time intervals including 4, 8, 12, 24 and 36 hours. The pain scores were measured with patients in a resting position. Morphine could also be administered with a patient controlled analgesia (PCA) pump if the specified analgesia was deemed inadequate (VAS > 5). None of the patients were withdrawn from the study. Parecoxib provided greater relief than placebo following TKA. The VAS pain scores measured at rest were statistically significantly lower in parecoxib-treated patients compared to the placebo group (P = 0.007) at 4 (P = 0.044), 12 (P = 0.001), and 24 hours (P = 0.012), postoperatively. Patients receiving parecoxib consumed less morphine at all time intervals than patients receiving placebo, with borderline statistical significance (P = 0.054). In each time period, all patients receiving continuous femoral block irrespectively of the treatment group, required low morphine doses. Current protocol did not answer question as to functional recovery. According to our findings intravenous parecoxib in combination with continuous femoral block provided superior analgesic efficacy and opioid sparing effects in patients undergoing TKA.

  3. Design of time interval generator based on hybrid counting method

    NASA Astrophysics Data System (ADS)

    Yao, Yuan; Wang, Zhaoqi; Lu, Houbing; Chen, Lian; Jin, Ge

    2016-10-01

    Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some "off-the-shelf" TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.

  4. Effect of spinal needle characteristics on measurement of spinal canal opening pressure.

    PubMed

    Bellamkonda, Venkatesh R; Wright, Thomas C; Lohse, Christine M; Keaveny, Virginia R; Funk, Eric C; Olson, Michael D; Laack, Torrey A

    2017-05-01

    A wide variety of spinal needles are used in clinical practice. Little is currently known regarding the impact of needle length, gauge, and tip type on the needle's ability to measure spinal canal opening pressure. This study aimed to investigate the relationship between these factors and the opening-pressure measurement or time to obtain an opening pressure. Thirteen distinct spinal needles, chosen to isolate the effects of length, gauge, and needle-point type, were prospectively tested on a lumbar puncture simulator. The key outcomes were the opening-pressure measurement and the time required to obtain that measure. Pressures were recorded at 10-s intervals until 3 consecutive, identical readings were observed. Time to measure opening pressure increased with increasing spinal needle length, increasing gauge, and the Quincke-type (cutting) point (P<0.001 for all). The time to measurement ranged from 30s to 530s, yet all needle types were able to obtain a consistent opening pressure measure. Although opening pressure estimates are unlikely to vary markedly by needle type, the time required to obtain the measurement increased with increasing needle length and gauge and with Quincke-type needles. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Circadian Clocks for All Meal-Times: Anticipation of 2 Daily Meals in Rats

    PubMed Central

    Mistlberger, Ralph E.; Kent, Brianne A.; Chan, Sofina; Patton, Danica F.; Weinberg, Alexander; Parfyonov, Maksim

    2012-01-01

    Anticipation of a daily meal in rats has been conceptualized as a rest-activity rhythm driven by a food-entrained circadian oscillator separate from the pacemaker generating light-dark (LD) entrained rhythms. Rats can also anticipate two daily mealtimes, but whether this involves independently entrained oscillators, one ‘continuously consulted’ clock, cue-dependent non-circadian interval timing or a combination of processes, is unclear. Rats received two daily meals, beginning 3-h (meal 1) and 13-h (meal 2) after lights-on (LD 14∶10). Anticipatory wheel running began 68±8 min prior to meal 1 and 101±9 min prior to meal 2 but neither the duration nor the variability of anticipation bout lengths exhibited the scalar property, a hallmark of interval timing. Meal omission tests in LD and constant dark (DD) did not alter the timing of either bout of anticipation, and anticipation of meal 2 was not altered by a 3-h advance of meal 1. Food anticipatory running in this 2-meal protocol thus does not exhibit properties of interval timing despite the availability of external time cues in LD. Across all days, the two bouts of anticipation were uncorrelated, a result more consistent with two independently entrained oscillators than a single consulted clock. Similar results were obtained for meals scheduled 3-h and 10-h after lights-on, and for a food-bin measure of anticipation. Most rats that showed weak or no anticipation to one or both meals exhibited elevated activity at mealtime during 1 or 2 day food deprivation tests in DD, suggesting covert operation of circadian timing in the absence of anticipatory behavior. A control experiment confirmed that daytime feeding did not shift LD-entrained rhythms, ruling out displaced nocturnal activity as an explanation for daytime activity. The results favor a multiple oscillator basis for 2-meal anticipatory rhythms and provide no evidence for involvement of cue-dependent interval timing. PMID:22355393

  6. Complex reference values for endocrine and special chemistry biomarkers across pediatric, adult, and geriatric ages: establishment of robust pediatric and adult reference intervals on the basis of the Canadian Health Measures Survey.

    PubMed

    Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David

    2015-08-01

    Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.

  7. Clinical assessment of gastric emptying and sensory function utilizing gamma scintigraphy: Establishment of reference intervals for the liquid and solid components of the Nottingham test meal in healthy subjects.

    PubMed

    Parker, H L; Tucker, E; Blackshaw, E; Hoad, C L; Marciani, L; Perkins, A; Menne, D; Fox, M

    2017-11-01

    Current investigations of stomach function are based on small test meals that do not reliably induce symptoms and analysis techniques that rarely detect clinically relevant dysfunction. This study presents the reference intervals of the modular "Nottingham test meal" (NTM) for assessment of gastric function by gamma scintigraphy (GSc) in a representative population of healthy volunteers (HVs) stratified for age and sex. The NTM comprises 400 mL liquid nutrient (0.75 kcal/mL) and an optional solid component (12 solid agar-beads (0 kcal). Filling and dyspeptic sensations were documented by 100 mm visual analogue scale (VAS). Gamma scintigraphy parameters that describe early and late phase Gastric emptying (GE) were calculated from validated models. Gastric emptying (GE) of the liquid component was measured in 73 HVs (male 34; aged 45±20). The NTM produced normal postprandial fullness (VAS ≥30 in 41/74 subjects). Dyspeptic symptoms were rare (VAS ≥30 in 2/74 subjects). Gastric emptying half-time with the Liquid- and Solid-component -NTM was median 44 (95% reference interval 28-78) minutes and 162 (144-193) minutes, respectively. Gastric accommodation was assessed by the ratio of the liquid-NTM retained in the proximal:total stomach and by Early phase emptying assessed by gastric volume after completing the meal (GCV0). No consistent effect of anthropometric measures on GE parameters was present. Reference intervals are presented for GSc measurements of gastric motor and sensory function assessed by the NTM. Studies involving patients are required to determine whether the reference interval range offers optimal diagnostic sensitivity and specificity. © 2017 The Authors. Neurogastroenterology & Motility Published by John Wiley & Sons Ltd.

  8. Fourth-grade children's dietary recall accuracy is influenced by retention interval (target period and interview time).

    PubMed

    Baxter, Suzanne Domel; Hardin, James W; Guinn, Caroline H; Royer, Julie A; Mackelprang, Alyssa J; Smith, Albert F

    2009-05-01

    For a 24-hour dietary recall, two possible target periods are the prior 24 hours (24 hours immediately preceding the interview time) and previous day (midnight to midnight of the day before the interview), and three possible interview times are morning, afternoon, and evening. Target period and interview time determine the retention interval (elapsed time between to-be-reported meals and the interview), which, along with intervening meals, can influence reporting accuracy. The effects of target period and interview time on children's accuracy for reporting school meals during 24-hour dietary recalls were investigated. DESIGN AND SUBJECTS/SETTING: During the 2004-2005, 2005-2006, and 2006-2007 school years in Columbia, SC, each of 374 randomly selected fourth-grade children (96% African American) was observed eating two consecutive school meals (breakfast and lunch) and interviewed to obtain a 24-hour dietary recall using one of six conditions defined by crossing two target periods with three interview times. Each condition had 62 or 64 children (half boys). Accuracy for reporting school meals was quantified by calculating rates for omissions (food items observed eaten but unreported) and intrusions (food items reported eaten but unobserved); a measure of total inaccuracy combined errors for reporting food items and amounts. For each accuracy measure, analysis of variance was conducted with target period, interview time, their interaction, sex, interviewer, and school year in the model. There was a target-period effect and a target-period by interview-time interaction on omission rates, intrusion rates, and total inaccuracy (six P values <0.004). For prior-24-hour recalls compared to previous-day recalls, and for prior-24-hour recalls in the afternoon and evening compared to previous-day recalls in the afternoon and evening, omission rates were better by one third, intrusion rates were better by one half, and total inaccuracy was better by one third. To enhance children's dietary recall accuracy, target periods and interview times that minimize the retention interval should be chosen.

  9. Irrigation scheduling using soil moisture sensors

    USDA-ARS?s Scientific Manuscript database

    Soil moisture sensors were evaluated and used for irrigation scheduling in humid region. Soil moisture sensors were installed in soil at depths of 15cm, 30cm, and 61cm belowground. Soil volumetric water content was automatically measured by the sensors in a time interval of an hour during the crop g...

  10. Measuring Preschool Cognitive Growth while It's Still Happening: The Learning Express

    ERIC Educational Resources Information Center

    McDermott, Paul A.; Fantuzzo, John W.; Waterman, Clare; Angelo, Lauren E.; Warley, Heather P.; Gadsden, Vivian L.; Zhang, Xiuyuan

    2009-01-01

    Educators need accurate assessments of preschool cognitive growth to guide curriculum design, evaluation, and timely modification of their instructional programs. But available tests do not provide content breadth or growth sensitivity over brief intervals. This article details evidence for a multiform, multiscale test criterion-referenced to…

  11. Analysis of vector wind change with respect to time for Vandenberg Air Force Base, California

    NASA Technical Reports Server (NTRS)

    Adelfang, S. I.

    1978-01-01

    A statistical analysis of the temporal variability of wind vectors at 1 km altitude intervals from 0 to 27 km altitude taken from a 10-year data sample of twice-daily rawinsode wind measurements over Vandenberg Air Force Base, California is presented.

  12. Rate of Visual Information Pick-Up in Learning Disabled and Normal Boys.

    ERIC Educational Resources Information Center

    Bryant, Susan K.; And Others

    1983-01-01

    A span-of-apprehension task and a backward masking technique were combined to allow measurement of the apprehension span of a sample of 34 learning disabled and normal boys about 8 to 13 years old at various time intervals following stimulus presentation. (Author/SW)

  13. A digital indicator for maximum windspeeds.

    Treesearch

    William B. Fowler

    1969-01-01

    A simple device for indicating maximum windspeed during a time interval is described. Use of a unijunction transistor, for voltage sensing, results in a stable comparison circuit and also reduces overall component requirements. Measurement is presented digitally in 1-mile-per-hour increments over the range of 0-51 m.p.h.

  14. A flexible 32-channel time-to-digital converter implemented in a Xilinx Zynq-7000 field programmable gate array

    NASA Astrophysics Data System (ADS)

    Wang, Yonggang; Kuang, Jie; Liu, Chong; Cao, Qiang; Li, Deng

    2017-03-01

    A high performance multi-channel time-to-digital converter (TDC) is implemented in a Xilinx Zynq-7000 field programmable gate array (FPGA). It can be flexibly configured as either 32 TDC channels with 9.9 ps time-interval RMS precision, 16 TDC channels with 6.9 ps RMS precision, or 8 TDC channels with 5.8 ps RMS precision. All TDCs have a 380 M Samples/second measurement throughput and a 2.63 ns measurement dead time. The performance consistency and temperature dependence of TDC channels are also evaluated. Because Zynq-7000 FPGA family integrates a feature-rich dual-core ARM based processing system and 28 nm Xilinx programmable logic in a single device, the realization of high performance TDCs on it will make the platform more widely used in time-measuring related applications.

  15. Time perception, pacing and exercise intensity: maximal exercise distorts the perception of time.

    PubMed

    Edwards, A M; McCormick, A

    2017-10-15

    Currently there are no data examining the impact of exercise on the perception of time, which is surprising as optimal competitive performance is dependent on accurate pacing using knowledge of time elapsed. With institutional ethics approval, 12 recreationally active adult participants (f=7, m=5) undertook both 30s Wingate cycles and 20min (1200s) rowing ergometer bouts as short and long duration self-paced exercise trials, in each of three conditions on separate occasions: 1) light exertion: RPE 11, 2) heavy exertion: RPE 15, 3) maximal exertion: RPE 20. Participants were unaware of exercise duration and were required to verbally indicate when they perceived (subjective time) 1) 25%, 2) 50%, 3) 75% and 4) 100% of each bout's measured (chronological) time had elapsed. In response to the Wingate task, there was no difference between durations of subjective time at the 25%, nor at the 50% interval. However, at the 75% and 100% intervals, the estimate for the RPE 20 condition was shortest (P<0.01). In response to rowing, there were no differences at the 25% interval, but there was some evidence that the RPE 20 condition was perceived shorter at 50%. At 75% and 100%, the RPE 20 condition was perceived to be shorter than both RPE 15 (P=0.04) and RPE 11 (P=0.008) conditions. This study is the first to empirically demonstrate that exercise intensity distorts time perception, particularly during maximal exercise. Consequently external feedback of chronological time may be an important factor for athletes undertaking maximal effort tasks or competitions. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Endurance and sprint benefits of high-intensity and supramaximal interval training.

    PubMed

    Cicioni-Kolsky, Daniel; Lorenzen, Christian; Williams, Morgan David; Kemp, Justin Guy

    2013-01-01

    This study examined the effect of two different interval training programs-high-intensity interval training (HIT) and supramaximal interval training (SMIT)-on measures of sprint and endurance performance. Physically active individuals (Females: n=32; age 19.3, s=2.2 years; mass 67.6, s=9.1 kg; stature 172.7, s=6.6 cm. Males: n=23; age 20.0, s=2.7 years; mass 71.3, s=8.3 kg; stature 176.6, s=5.8 cm) completed pre-testing that comprised (1) 3000 m time-trial, (2) 40 m sprint, and (3) repeated sprint ability (RSA-6×40 m sprints, 24 s active recovery) performance. Participants were then matched for average 3000 m running velocity (AV) and randomly assigned to one of three groups: (i) HIT, n=19, 4 min at 100% AV, 4 min passive recovery, 4-6 bouts per session; (ii) SMIT, n=20, 30 s at 130% AV, 150 s passive recovery, 7-12 bouts per session; and (iii) control group, n=16, 30 min continuous running at 75% AV. Groups trained three times per week for six weeks. When time to complete each test were compared among groups: (i) improvements in 3000 m time trial performance were greater following SMIT than continuous running, and (ii) improvements in 40 m sprint and RSA performance were greater following SMIT than HIT and continuous running. In addition, a gender effect was observed for the 3000 m time trial only, where females changed more following the training intervention than males. In summary, for concurrent improvements in endurance, sprint and repeated sprint performance, SMIT provides the greatest benefits for physically active individuals.

  17. Time reproduction performance is associated with age and working memory in high-functioning youth with autism spectrum disorder.

    PubMed

    Brenner, Laurie A; Shih, Vivian H; Colich, Natalie L; Sugar, Catherine A; Bearden, Carrie E; Dapretto, Mirella

    2015-02-01

    Impaired temporal processing has historically been viewed as a hallmark feature of attention deficit hyperactivity disorder. Recent evidence suggests temporal processing deficits may also be characteristic of autism spectrum disorder (ASD). However, little is known about the factors that impact temporal processing in children with ASD. The purpose of this study was to assess the effects of co-morbid attention problems, working memory (WM), age, and their interactions, on time reproduction in youth with and without ASD. Twenty-seven high-functioning individuals with ASD and 25 demographically comparable typically developing individuals (ages 9-17; 85% male) were assessed on measures of time reproduction, auditory WM, and inattention/hyperactivity. The time reproduction task required depression of a computer key to mimic interval durations of 4, 8, 12, 16, or 20 sec. Mixed effects regression analyses were used to model accuracy and variability of time reproduction as functions of diagnostic group, interval duration, age, WM, and inattention/hyperactivity. A significant group by age interaction was detected for accuracy, with the deficit in the ASD group being greater in younger children. There was a significant group by WM interaction for consistency, with the effects of poor WM on performance consistency being more pronounced in youth with ASD. All participants tended to underestimate longer interval durations and to be less consistent for shorter interval durations; these effects appeared more pronounced in those who were younger or who had poorer WM performance. Inattention/hyperactivity symptoms in the ASD group were not related to either accuracy or consistency. This study highlights the potential value of temporal processing as an intermediate trait of relevance to multiple neurodevelopmental disorders. © 2014 International Society for Autism Research, Wiley Periodicals, Inc.

  18. The NANOGrav Observing Program: High-precision Millisecond Pulsar Timing and the Search for Nanohertz Gravitational Waves

    NASA Astrophysics Data System (ADS)

    Nice, David; NANOGrav

    2018-01-01

    The North American Observatory for Nanohertz Gravitational Waves (NANOGrav) collaboration is thirteen years into a program of long-term, high-precision millisecond pulsar timing, undertaken with the goal of detecting and characterization nanohertz gravitational waves (i.e., gravitational waves with periods of many years) by measuring their effect on observed pulse arrival times. Our primary instruments are the Arecibo Observatory, used to observe 37 pulsars with declinations between 0 and 39 degrees; and the Green Bank Telescope, used for 24 pulsars, of which 22 are outside the Arecibo range, and 2 are overlaps with the Arecibo source list. Additional observations are made with the VLA and (soon) CHIME.Most pulsars in our program are observed at intervals of three to four weeks, and seven are observed weekly. Observations of each pulsar are made over a wide range of radio frequencies at each epoch in order to measure and mitigate effects of the ionized interstellar medium on the pulse arrival times. Our targets are pulsars for which we can achieve timing precision of 1 microsecond or better in at each epoch; we achieve precision better than 100 nanoseconds in the best cases. Observing a large number of pulsars will allow for robust measurements of gravitational waves by analyzing correlations in the timing of pairs of pulsars depending on their separation on the sky. Our data are pooled with data from telescopes worldwide via the International Pulsar Timing Array (IPTA) collaboration, further increasing our sensitivity to gravitational waves.We release data at regular intervals. We will describe the NANOGrav 5-, 9- and 11-year data sets and give a status report on the NANOGrav 12.5-year data set.

  19. Failed Deglutitive Upper Esophageal Sphincter Relaxation Is a Risk Factor for Aspiration in Stroke Patients with Oropharyngeal Dysphagia.

    PubMed

    Lee, Taeheon; Park, Jung Ho; Sohn, Chongil; Yoon, Kyung Jae; Lee, Yong-Taek; Park, Jung Hwan; Jung, Il Seok

    2017-01-30

    We attempted to examine the relationship between abnormal findings on high-resolution manometry (HRM) and videofluoroscopic swallowing study (VFSS) of the pharynx and upper esophageal sphincter (UES), and to identify the risk factors for aspiration. We performed VFSS and HRM on the same day in 36 ischemic stroke patients (mean age, 67.5 years) with dysphagia. Pressure (basal, median intra bolus, and nadir), relaxation time interval of the UES, and mesopharyngeal and hypopharyngeal contractility (as a contractile integral) were examined using HRM. The parameters of VFSS were vallecular residue, pyriform sinus residue, vallecular overflow, penetration, and aspiration. The association between the parameters of VFSS and HRM was analyzed by the Student's t test. Three (8.3%) and 4 (11.1%) stroke patients with dysphagia had pyriform sinus residue and vallecular sinus residue, respectively, and 5 (13.8%) patients showed aspiration. Mesopharyngeal and hypopharyngeal contractile integrals in patients with residue in the pyriform sinus were significantly lower than those in patients without residue in the pyriform sinus ( P < 0.05). Relaxation time intervals in patients with aspiration were significantly shorter than those in patients without aspiration ( P < 0.05), and multivariate regression analysis revealed a shorter relaxation time interval as the main risk factor for aspiration (OR, 0.03; 95% CI, 0.01-0.65; P < 0.05). Manometric measurements of the pharynx and UES were well correlated with abnormal findings in the VFSS, and a shorter relaxation time interval of the UES during deglutition is an important parameter for the development of aspiration.

  20. New insight for activity intensity relativity, metabolic expenditure during object projection skill performance.

    PubMed

    Sacko, Ryan S; McIver, Kerry; Brian, Ali; Stodden, David F

    2018-04-02

    This study examined the metabolic cost (METs) of performing object projection skills at three practice trial intervals (6, 12, and 30 seconds). Forty adults (female n = 20) aged 18-30 (M = 23.7 ± 2.9 years) completed three, nine-minute sessions of skill trials performed at 6, 12, and 30 second intervals. Participants performed kicking, throwing and striking trials in a blocked schedule with maximal effort. Average METs during each session were measured using a COSMED K4b2. A three (interval condition) X two (sex) ANOVA was conducted to examine differences in METs across interval conditions and by sex. Results indicated a main effect for interval condition (F(5,114) = 187.02, p < .001, η 2  = 0.76) with decreased interval times yielding significantly higher METs [30 sec = 3.45, 12 sec = 5.68, 6 sec = 8.21]. A main effect for sex (F(5, 114) = 35.39, p < .001, η 2  = 0.24) also was found with men demonstrating higher METs across all intervals. At a rate of only two trials/min, participants elicited moderate physical activity, with 12 and 6-second intervals exhibiting vigorous PA. Demonstrating MVPA during the performance of object projection skill performance has potential implications for PA interventions.

Top