Department of Defense Precise Time and Time Interval program improvement plan
NASA Technical Reports Server (NTRS)
Bowser, J. R.
1981-01-01
The United States Naval Observatory is responsible for ensuring uniformity in precise time and time interval operations including measurements, the establishment of overall DOD requirements for time and time interval, and the accomplishment of objectives requiring precise time and time interval with minimum cost. An overview of the objectives, the approach to the problem, the schedule, and a status report, including significant findings relative to organizational relationships, current directives, principal PTTI users, and future requirements as currently identified by the users are presented.
Goff, M L; Win, B H
1997-11-01
The postmortem interval for a set of human remains discovered inside a metal tool box was estimated using the development time required for a stratiomyid fly (Diptera: Stratiomyidae), Hermetia illucens, in combination with the time required to establish a colony of the ant Anoplolepsis longipes (Hymenoptera: Formicidae) capable of producing alate (winged) reproductives. This analysis resulted in a postmortem interval estimate of 14 + months, with a period of 14-18 months being the most probable time interval. The victim had been missing for approximately 18 months.
A Role for Memory in Prospective Timing informs Timing in Prospective Memory
Waldum, Emily R; Sahakyan, Lili
2014-01-01
Time-based prospective memory (TBPM) tasks require the estimation of time in passing – known as prospective timing. Prospective timing is said to depend on an attentionally-driven internal clock mechanism, and is thought to be unaffected by memory for interval information (for reviews see, Block, Hancock, & Zakay, 2010; Block & Zakay, 1997). A prospective timing task that required a verbal estimate following the entire interval (Experiment 1) and a TBPM task that required production of a target response during the interval (Experiment 2) were used to test an alternative view that episodic memory does influence prospective timing. In both experiments, participants performed an ongoing lexical decision task of fixed duration while a varying number of songs were played in the background. Experiment 1 results revealed that verbal time estimates became longer the more songs participants remembered from the interval, suggesting that memory for interval information influences prospective time estimates. In Experiment 2, participants who were asked to perform the TBPM task without the aid of an external clock made their target responses earlier as the number of songs increased, indicating that prospective estimates of elapsed time increased as more songs were experienced. For participants who had access to a clock, changes in clock-checking coincided with the occurrence of song boundaries, indicating that participants used both song information and clock information to estimate time. Finally, ongoing task performance and verbal reports in both experiments further substantiate a role for episodic memory in prospective timing. PMID:22984950
Gilaie-Dotan, Sharon; Ashkenazi, Hamutal; Dar, Reuven
2016-01-01
One of the main characteristics of obsessive-compulsive disorder (OCD) is the persistent feeling of uncertainty, affecting many domains of actions and feelings. It was recently hypothesized that OCD uncertainty is related to attenuated access to internal states. As supra-second timing is associated with bodily and interoceptive awareness, we examined whether supra-second timing would be associated with OC tendencies. We measured supra-second (~9 s) and sub-second (~450 ms) timing along with control non-temporal perceptual tasks in a group of 60 university students. Supra-second timing was measured either with fixed criterion tasks requiring to temporally discriminate between two predefined fixed interval durations (9 vs. 9.9 s), or with an open-ended task requiring to discriminate between 9 s and longer intervals which were of varying durations that were not a priori known to the participants. The open-ended task employed an adaptive Bayesian procedure that efficiently estimated the duration difference required to discriminate 9 s from longer intervals. We also assessed symptoms of OCD, depression, and anxiety. Open-ended supra-second temporal sensitivity was correlated with OC tendencies, as predicted (even after controlling for depression and anxiety), whereas the other tasks were not. Higher OC tendencies were associated with lower timing sensitivity to 9 s intervals such that participants with higher OC tendency scores required longer interval differences to discriminate 9 s from longer intervals. While these results need to be substantiated in future research, they suggest that open-ended timing tasks, as those encountered in real-life (e.g., estimating how long it would take to complete a task), might be adversely affected in OCD. PMID:27445725
Sabbuba, N A; Stickler, D J; Long, M J; Dong, Z; Short, T D; Feneley, R J C
2005-01-01
We tested whether valve regulated, intermittent flow of urine from catheterized bladders decreases catheter encrustation. Laboratory models of the catheterized bladder were infected with Proteus mirabilis. Urine was allowed to drain continuously through the catheters or regulated by valves to drain intermittently at predetermined intervals. The time that catheters required to become blocked was recorded and encrustation was visualized by scanning electron microscopy. When a manual valve was used to drain urine from the bladder at 2-hour intervals 4 times during the day, catheters required significantly longer to become blocked than those on continuous drainage (mean 62.6 vs 35.9 hours, p = 0.039). A similar 1.7-fold increase occurred when urine was drained at 4-hour intervals 3 times daily. Experiments with an automatic valve in which urine was released at 2 or 4-hour intervals through the day and night also showed a significant increase in mean time to blockage compared with continuous drainage (p = 0.001). Scanning electron microscopy confirmed that crystalline biofilm was less extensive on valve regulated catheters. Valve regulated, intermittent flow of urine through catheters increases the time that catheters require to become blocked with crystalline biofilm. The most beneficial effect was recorded when urine was released from the bladder at 4-hour intervals throughout the day and night by an automatic valve.
Measuring Time on the PET and Other Microcomputers
ERIC Educational Resources Information Center
Tesler, Larry
1978-01-01
The operation of the microcomputer requires one or more clocks or timers to measure intervals of different magnitudes. Methods are discussed for measuring time intervals on PET in hours, minutes, seconds, microseconds, miscellaneous units, and timing events on external devices. Directions are added for BASIC program applications of timing…
Recurrence time statistics for finite size intervals
NASA Astrophysics Data System (ADS)
Altmann, Eduardo G.; da Silva, Elton C.; Caldas, Iberê L.
2004-12-01
We investigate the statistics of recurrences to finite size intervals for chaotic dynamical systems. We find that the typical distribution presents an exponential decay for almost all recurrence times except for a few short times affected by a kind of memory effect. We interpret this effect as being related to the unstable periodic orbits inside the interval. Although it is restricted to a few short times it changes the whole distribution of recurrences. We show that for systems with strong mixing properties the exponential decay converges to the Poissonian statistics when the width of the interval goes to zero. However, we alert that special attention to the size of the interval is required in order to guarantee that the short time memory effect is negligible when one is interested in numerically or experimentally calculated Poincaré recurrence time statistics.
Stoller, James K; Kester, Lucy; Orens, Douglas K; McCarthy, Kevin
2002-08-01
Although radio frequency (RF) systems have proliferated and are designed to simplify care delivery in many clinical settings, little information is available on the impact of such RF systems on the delivery of patient care. Having used a hand-held-device-based management information system in our Respiratory Therapy Section for 16 years, we assessed the impact of an RF system on the delivery of respiratory therapy (RT) services. A single nursing unit dedicated to pulmonary and ear, nose, and throat care was selected for the RF system trial. Baseline (pre-RF) data were collected over 2 separate 1-month intervals (February 1999 and February 2000). The main outcome measures were (1) the amount of time needed at the beginning of the shift to organize and assign orders for RT services, (2) the time interval between notification of an RT consult order and completion of the RT consult, and (3) the time interval between notification of an RT treatment order and completion of the RT treatment. The activities required for organizing and assigning the orders were manually timed. Starting 6 weeks after therapists were trained to use the RF system, similar data were collected while using the RF system for two 1-month intervals (February and March 2001). The mean +/- SD time interval between receiving an RT consult order and completing the consult was reduced from 7.8 +/- 18.9 h to 2.8 +/- 2.4 h (p = 0.002). The percentage of patients who waited longer than 8 hours between receipt of a consult order and completion of the consult decreased from 18% to 4.7% (p = 0.026). The total time required for organizing and assigning RT work was reduced from 81.6 min to 43.6 min. The RF system had several advantages over the hand-held-device-based system: (1) shorter interval between the order for and completion of an RT consult, (2) lower percentage of patients for whom the interval between the order and the consult exceeded 8 hours, and (3) less time required to make shift assignments. These results invite assessment of whether accelerated delivery of RT services confers clinical benefits.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-29
... maximum time interval between any engine run-ups from idle and the minimum ambient temperature associated with that run-up interval. This limitation is necessary because we do not currently have any specific requirements for run-up procedures for engine ground operation in icing conditions. The engine run-up procedure...
Gillard, Jonathan
2015-12-01
This article re-examines parametric methods for the calculation of time specific reference intervals where there is measurement error present in the time covariate. Previous published work has commonly been based on the standard ordinary least squares approach, weighted where appropriate. In fact, this is an incorrect method when there are measurement errors present, and in this article, we show that the use of this approach may, in certain cases, lead to referral patterns that may vary with different values of the covariate. Thus, it would not be the case that all patients are treated equally; some subjects would be more likely to be referred than others, hence violating the principle of equal treatment required by the International Federation for Clinical Chemistry. We show, by using measurement error models, that reference intervals are produced that satisfy the requirement for equal treatment for all subjects. © The Author(s) 2011.
Measuring the EMS patient access time interval and the impact of responding to high-rise buildings.
Morrison, Laurie J; Angelini, Mark P; Vermeulen, Marian J; Schwartz, Brian
2005-01-01
To measure the patient access time interval and characterize its contribution to the total emergency medical services (EMS) response time interval; to compare the patient access time intervals for patients located three or more floors above ground with those less than three floors above or below ground, and specifically in the apartment subgroup; and to identify barriers that significantly impede EMS access to patients in high-rise apartments. An observational study of all patients treated by an emergency medical technician paramedics (EMT-P) crew was conducted using a trained independent observer to collect time intervals and identify potential barriers to access. Of 118 observed calls, 25 (21%) originated from patients three or more floors above ground. The overall median and 90th percentile (95% confidence interval) patient access time intervals were 1.61 (1.27, 1.91) and 3.47 (3.08, 4.05) minutes, respectively. The median interval was 2.73 (2.22, 3.03) minutes among calls from patients located three or more stories above ground compared with 1.25 (1.07, 1.55) minutes among those at lower levels. The patient access time interval represented 23.5% of the total EMS response time interval among calls originating less than three floors above or below ground and 32.2% of those located three or more stories above ground. The most frequently encountered barriers to access included security code entry requirements, lack of directional signs, and inability to fit the stretcher into the elevator. The patient access time interval is significantly long and represents a substantial component of the total EMS response time interval, especially among ambulance calls originating three or more floors above ground. A number of barriers appear to contribute to delayed paramedic access.
33 CFR 150.503 - What are the time interval requirements for maintenance on survival craft falls?
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements for maintenance on survival craft falls? 150.503 Section 150.503 Navigation and Navigable Waters... maintenance on survival craft falls? (a) Each fall used in a launching device for survival craft or rescue boats must be turned end-for-end at intervals of not more than 30 months. (b) Each fall must be replaced...
33 CFR 150.503 - What are the time interval requirements for maintenance on survival craft falls?
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements for maintenance on survival craft falls? 150.503 Section 150.503 Navigation and Navigable Waters... maintenance on survival craft falls? (a) Each fall used in a launching device for survival craft or rescue boats must be turned end-for-end at intervals of not more than 30 months. (b) Each fall must be replaced...
33 CFR 150.503 - What are the time interval requirements for maintenance on survival craft falls?
Code of Federal Regulations, 2011 CFR
2011-07-01
... requirements for maintenance on survival craft falls? 150.503 Section 150.503 Navigation and Navigable Waters... maintenance on survival craft falls? (a) Each fall used in a launching device for survival craft or rescue boats must be turned end-for-end at intervals of not more than 30 months. (b) Each fall must be replaced...
33 CFR 150.503 - What are the time interval requirements for maintenance on survival craft falls?
Code of Federal Regulations, 2012 CFR
2012-07-01
... requirements for maintenance on survival craft falls? 150.503 Section 150.503 Navigation and Navigable Waters... maintenance on survival craft falls? (a) Each fall used in a launching device for survival craft or rescue boats must be turned end-for-end at intervals of not more than 30 months. (b) Each fall must be replaced...
33 CFR 150.503 - What are the time interval requirements for maintenance on survival craft falls?
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements for maintenance on survival craft falls? 150.503 Section 150.503 Navigation and Navigable Waters... maintenance on survival craft falls? (a) Each fall used in a launching device for survival craft or rescue boats must be turned end-for-end at intervals of not more than 30 months. (b) Each fall must be replaced...
a New Approach for Accuracy Improvement of Pulsed LIDAR Remote Sensing Data
NASA Astrophysics Data System (ADS)
Zhou, G.; Huang, W.; Zhou, X.; He, C.; Li, X.; Huang, Y.; Zhang, L.
2018-05-01
In remote sensing applications, the accuracy of time interval measurement is one of the most important parameters that affect the quality of pulsed lidar data. The traditional time interval measurement technique has the disadvantages of low measurement accuracy, complicated circuit structure and large error. A high-precision time interval data cannot be obtained in these traditional methods. In order to obtain higher quality of remote sensing cloud images based on the time interval measurement, a higher accuracy time interval measurement method is proposed. The method is based on charging the capacitance and sampling the change of capacitor voltage at the same time. Firstly, the approximate model of the capacitance voltage curve in the time of flight of pulse is fitted based on the sampled data. Then, the whole charging time is obtained with the fitting function. In this method, only a high-speed A/D sampler and capacitor are required in a single receiving channel, and the collected data is processed directly in the main control unit. The experimental results show that the proposed method can get error less than 3 ps. Compared with other methods, the proposed method improves the time interval accuracy by at least 20 %.
Statistical inferences with jointly type-II censored samples from two Pareto distributions
NASA Astrophysics Data System (ADS)
Abu-Zinadah, Hanaa H.
2017-08-01
In the several fields of industries the product comes from more than one production line, which is required to work the comparative life tests. This problem requires sampling of the different production lines, then the joint censoring scheme is appeared. In this article we consider the life time Pareto distribution with jointly type-II censoring scheme. The maximum likelihood estimators (MLE) and the corresponding approximate confidence intervals as well as the bootstrap confidence intervals of the model parameters are obtained. Also Bayesian point and credible intervals of the model parameters are presented. The life time data set is analyzed for illustrative purposes. Monte Carlo results from simulation studies are presented to assess the performance of our proposed method.
Method of high precision interval measurement in pulse laser ranging system
NASA Astrophysics Data System (ADS)
Wang, Zhen; Lv, Xin-yuan; Mao, Jin-jin; Liu, Wei; Yang, Dong
2013-09-01
Laser ranging is suitable for laser system, for it has the advantage of high measuring precision, fast measuring speed,no cooperative targets and strong resistance to electromagnetic interference,the measuremen of laser ranging is the key paremeters affecting the performance of the whole system.The precision of the pulsed laser ranging system was decided by the precision of the time interval measurement, the principle structure of laser ranging system was introduced, and a method of high precision time interval measurement in pulse laser ranging system was established in this paper.Based on the analysis of the factors which affected the precision of range measure,the pulse rising edges discriminator was adopted to produce timing mark for the start-stop time discrimination,and the TDC-GP2 high precision interval measurement system based on TMS320F2812 DSP was designed to improve the measurement precision.Experimental results indicate that the time interval measurement method in this paper can obtain higher range accuracy. Compared with the traditional time interval measurement system,the method simplifies the system design and reduce the influence of bad weather conditions,furthermore,it satisfies the requirements of low costs and miniaturization.
Time estimation by patients with frontal lesions and by Korsakoff amnesics.
Mimura, M; Kinsbourne, M; O'Connor, M
2000-07-01
We studied time estimation in patients with frontal damage (F) and alcoholic Korsakoff (K) patients in order to differentiate between the contributions of working memory and episodic memory to temporal cognition. In Experiment 1, F and K patients estimated time intervals between 10 and 120 s less accurately than matched normal and alcoholic control subjects. F patients were less accurate than K patients at short (< 1 min) time intervals whereas K patients increasingly underestimated durations as intervals grew longer. F patients overestimated short intervals in inverse proportion to their performance on the Wisconsin Card Sorting Test. As intervals grew longer, overestimation yielded to underestimation for F patients. Experiment 2 involved time estimation while counting at a subjective 1/s rate. F patients' subjective tempo, though relatively rapid, did not fully explain their overestimation of short intervals. In Experiment 3, participants produced predetermined time intervals by depressing a mouse key. K patients underproduced longer intervals. F patients produced comparably to normal participants, but were extremely variable. Findings suggest that both working memory and episodic memory play an individual role in temporal cognition. Turnover within a short-term working memory buffer provides a metric for temporal decisions. The depleted working memory that typically attends frontal dysfunction may result in quicker turnover, and this may inflate subjective duration. On the other hand, temporal estimation beyond 30 s requires episodic remembering, and this puts K patients at a disadvantage.
Fielden, Claire A; Kluk, Karolina; McKay, Colette M
2014-05-01
Perception of temporal patterns is crucial to speech understanding and music perception in normal hearing, and is fundamental in the design and implementation of processing strategies for cochlear implants. Two experiments described here investigated the effect of stimulation mode (monopolar versus tripolar) on interpulse interval discrimination using single-electrode stimulation (experiment 1) and dual-electrode stimulation (experiment 2). Experiment 1 required participants to discriminate stimuli containing different interpulse intervals and experiment 2 required listeners to discriminate between two dual-electrode stimuli that had the same temporal pattern on each electrode, but differed in inter-electrode timing. The hypotheses were that (i) stimulation mode would affect the ability to distinguish interpulse interval patterns on a single electrode and (ii) the electrode separation range in which subjects were sensitive to inter-electrode timing would be more restricted in tripolar than in monopolar stimulation. Results in nine cochlear implant users showed that mode did not have a significant mean effect on either the ability to discriminate interpulse intervals in single-electrode stimulation or the range of electrode separation in dual-electrode stimulation in which participants were sensitive to inter-electrode timing. In conclusion, tripolar stimulation did not show any advantage in delivering temporal information within or across channels in this group.
Psychophysical basis for consonant musical intervals
NASA Astrophysics Data System (ADS)
Resnick, L.
1981-06-01
A suggestion is made to explain the acceptance of certain musical intervals as consonant and others as dissonant. The proposed explanation involves the relation between the time required to perceive a definite pitch and the period of a complex tone. If the former time is greater than the latter, the tone is consonant; otherwise it is dissonant. A quantitative examination leads to agreement with empirical data.
Interval Management with Spacing to Parallel Dependent Runways (IMSPIDR) Experiment and Results
NASA Technical Reports Server (NTRS)
Baxley, Brian T.; Swieringa, Kurt A.; Capron, William R.
2012-01-01
An area in aviation operations that may offer an increase in efficiency is the use of continuous descent arrivals (CDA), especially during dependent parallel runway operations. However, variations in aircraft descent angle and speed can cause inaccuracies in estimated time of arrival calculations, requiring an increase in the size of the buffer between aircraft. This in turn reduces airport throughput and limits the use of CDAs during high-density operations, particularly to dependent parallel runways. The Interval Management with Spacing to Parallel Dependent Runways (IMSPiDR) concept uses a trajectory-based spacing tool onboard the aircraft to achieve by the runway an air traffic control assigned spacing interval behind the previous aircraft. This paper describes the first ever experiment and results of this concept at NASA Langley. Pilots flew CDAs to the Dallas Fort-Worth airport using airspeed calculations from the spacing tool to achieve either a Required Time of Arrival (RTA) or Interval Management (IM) spacing interval at the runway threshold. Results indicate flight crews were able to land aircraft on the runway with a mean of 2 seconds and less than 4 seconds standard deviation of the air traffic control assigned time, even in the presence of forecast wind error and large time delay. Statistically significant differences in delivery precision and number of speed changes as a function of stream position were observed, however, there was no trend to the difference and the error did not increase during the operation. Two areas the flight crew indicated as not acceptable included the additional number of speed changes required during the wind shear event, and issuing an IM clearance via data link while at low altitude. A number of refinements and future spacing algorithm capabilities were also identified.
A Deadline-Aware Scheduling and Forwarding Scheme in Wireless Sensor Networks.
Dao, Thi-Nga; Yoon, Seokhoon; Kim, Jangyoung
2016-01-05
Many applications in wireless sensor networks (WSNs) require energy consumption to be minimized and the data delivered to the sink within a specific delay. A usual solution for reducing energy consumption is duty cycling, in which nodes periodically switch between sleep and active states. By increasing the duty cycle interval, consumed energy can be reduced more. However, a large duty cycle interval causes a long end-to-end (E2E) packet delay. As a result, the requirement of a specific delay bound for packet delivery may not be satisfied. In this paper, we aim at maximizing the duty cycle while still guaranteeing that the packets arrive at the sink with the required probability, i.e., the required delay-constrained success ratio (DCSR) is achieved. In order to meet this objective, we propose a novel scheduling and forwarding scheme, namely the deadline-aware scheduling and forwarding (DASF) algorithm. In DASF, the E2E delay distribution with the given network model and parameters is estimated in order to determine the maximum duty cycle interval, with which the required DCSR is satisfied. Each node independently selects a wake-up time using the selected interval, and packets are forwarded to a node in the potential forwarding set, which is determined based on the distance between nodes and the sink. DASF does not require time synchronization between nodes, and a node does not need to maintain neighboring node information in advance. Simulation results show that the proposed scheme can satisfy a required delay-constrained success ratio and outperforms existing algorithms in terms of E2E delay and DCSR.
A Deadline-Aware Scheduling and Forwarding Scheme in Wireless Sensor Networks
Dao, Thi-Nga; Yoon, Seokhoon; Kim, Jangyoung
2016-01-01
Many applications in wireless sensor networks (WSNs) require energy consumption to be minimized and the data delivered to the sink within a specific delay. A usual solution for reducing energy consumption is duty cycling, in which nodes periodically switch between sleep and active states. By increasing the duty cycle interval, consumed energy can be reduced more. However, a large duty cycle interval causes a long end-to-end (E2E) packet delay. As a result, the requirement of a specific delay bound for packet delivery may not be satisfied. In this paper, we aim at maximizing the duty cycle while still guaranteeing that the packets arrive at the sink with the required probability, i.e., the required delay-constrained success ratio (DCSR) is achieved. In order to meet this objective, we propose a novel scheduling and forwarding scheme, namely the deadline-aware scheduling and forwarding (DASF) algorithm. In DASF, the E2E delay distribution with the given network model and parameters is estimated in order to determine the maximum duty cycle interval, with which the required DCSR is satisfied. Each node independently selects a wake-up time using the selected interval, and packets are forwarded to a node in the potential forwarding set, which is determined based on the distance between nodes and the sink. DASF does not require time synchronization between nodes, and a node does not need to maintain neighboring node information in advance. Simulation results show that the proposed scheme can satisfy a required delay-constrained success ratio and outperforms existing algorithms in terms of E2E delay and DCSR. PMID:26742046
Comet Halley and nongravitational forces
NASA Technical Reports Server (NTRS)
Yeomans, D. K.
1977-01-01
The motion of comet Halley is investigated over the 1607-1911 interval. The required nongravitational-force model was found to be most consistent with a rocket-type thrust from the vaporization of water ice in the comet's nucleus. The nongravitational effects are time-independent over the investigated interval.
Fast transfer of crossmodal time interval training.
Chen, Lihan; Zhou, Xiaolin
2014-06-01
Sub-second time perception is essential for many important sensory and perceptual tasks including speech perception, motion perception, motor coordination, and crossmodal interaction. This study investigates to what extent the ability to discriminate sub-second time intervals acquired in one sensory modality can be transferred to another modality. To this end, we used perceptual classification of visual Ternus display (Ternus in Psychol Forsch 7:81-136, 1926) to implicitly measure participants' interval perception in pre- and posttests and implemented an intra- or crossmodal sub-second interval discrimination training protocol in between the tests. The Ternus display elicited either an "element motion" or a "group motion" percept, depending on the inter-stimulus interval between the two visual frames. The training protocol required participants to explicitly compare the interval length between a pair of visual, auditory, or tactile stimuli with a standard interval or to implicitly perceive the length of visual, auditory, or tactile intervals by completing a non-temporal task (discrimination of auditory pitch or tactile intensity). Results showed that after fast explicit training of interval discrimination (about 15 min), participants improved their ability to categorize the visual apparent motion in Ternus displays, although the training benefits were mild for visual timing training. However, the benefits were absent for implicit interval training protocols. This finding suggests that the timing ability in one modality can be rapidly acquired and used to improve timing-related performance in another modality and that there may exist a central clock for sub-second temporal processing, although modality-specific perceptual properties may constrain the functioning of this clock.
Belke, Terry W; Christie-Fougere, Melissa M
2006-11-01
Across two experiments, a peak procedure was used to assess the timing of the onset and offset of an opportunity to run as a reinforcer. The first experiment investigated the effect of reinforcer duration on temporal discrimination of the onset of the reinforcement interval. Three male Wistar rats were exposed to fixed-interval (FI) 30-s schedules of wheel-running reinforcement and the duration of the opportunity to run was varied across values of 15, 30, and 60s. Each session consisted of 50 reinforcers and 10 probe trials. Results showed that as reinforcer duration increased, the percentage of postreinforcement pauses longer than the 30-s schedule interval increased. On probe trials, peak response rates occurred near the time of reinforcer delivery and peak times varied with reinforcer duration. In a second experiment, seven female Long-Evans rats were exposed to FI 30-s schedules leading to 30-s opportunities to run. Timing of the onset and offset of the reinforcement period was assessed by probe trials during the schedule interval and during the reinforcement interval in separate conditions. The results provided evidence of timing of the onset, but not the offset of the wheel-running reinforcement period. Further research is required to assess if timing occurs during a wheel-running reinforcement period.
Proceedings of the 14th Annual Precise Time and Time Interval (PTTI) Applications Planning Meeting
NASA Technical Reports Server (NTRS)
Wardrip, S. C. (Editor)
1983-01-01
Developments and applications in the field of frequency and time are addressed. Specific topics include rubidium frequency standards, future timing requirements, noise and atomic standards, hydrogen maser technology, synchronization, and quartz technology.
The effect of clomiphene citrate on human preovulatory oocyte maturation in vivo.
Seibel, M M; Smith, D M
1989-02-01
Sixty-four infertile women underwent diagnostic laparoscopy in the periovulatory period at time-bracketed intervals following their endogenous luteinizing hormone (LH) surge. Forty-eight of these women were studied during natural cycles and 16 had mild oligoovulation and were administered clomiphene citrate (CC) to regulate their cycles. No patient received human chorionic gonadotropin. No patient was undergoing either in vitro fertilization (IVF) or gamete intrafallopian transfer (GIFT). Follicle puncture was performed and the oocytes were observed immediately for stage of maturation. Oocytes obtained from follicles exposed to CC were found to require an increased interval of time to reach metaphase I compared to oocytes obtained from natural cycles (27.75 +/- 2.2 vs 22.5 hr; mean +/- SE). Furthermore, the interval of time required for metaphase I oocytes to achieve metaphase II was statistically significantly shortened for CC cycles (2.4 hr for CC vs 10 hr for natural cycles. Nevertheless, there was no difference between natural and CC cycles in the time interval between LH surge onset and ovulation. These in vivo findings suggest a direct effect of CC on human oocyte maturation and may help explain the well-established discrepancy between the relatively high ovulation rate and the relatively low conception rate in clomiphene-induced cycles.
Li, Lingling; Kulldorff, Martin; Russek-Cohen, Estelle; Kawai, Alison Tse; Hua, Wei
2015-12-01
The self-controlled risk interval design is commonly used to assess the association between an acute exposure and an adverse event of interest, implicitly adjusting for fixed, non-time-varying covariates. Explicit adjustment needs to be made for time-varying covariates, for example, age in young children. It can be performed via either a fixed or random adjustment. The random-adjustment approach can provide valid point and interval estimates but requires access to individual-level data for an unexposed baseline sample. The fixed-adjustment approach does not have this requirement and will provide a valid point estimate but may underestimate the variance. We conducted a comprehensive simulation study to evaluate their performance. We designed the simulation study using empirical data from the Food and Drug Administration-sponsored Mini-Sentinel Post-licensure Rapid Immunization Safety Monitoring Rotavirus Vaccines and Intussusception study in children 5-36.9 weeks of age. The time-varying confounder is age. We considered a variety of design parameters including sample size, relative risk, time-varying baseline risks, and risk interval length. The random-adjustment approach has very good performance in almost all considered settings. The fixed-adjustment approach can be used as a good alternative when the number of events used to estimate the time-varying baseline risks is at least the number of events used to estimate the relative risk, which is almost always the case. We successfully identified settings in which the fixed-adjustment approach can be used as a good alternative and provided guidelines on the selection and implementation of appropriate analyses for the self-controlled risk interval design. Copyright © 2015 John Wiley & Sons, Ltd.
Dong, Yuwen; Deshpande, Sunil; Rivera, Daniel E; Downs, Danielle S; Savage, Jennifer S
2014-06-01
Control engineering offers a systematic and efficient method to optimize the effectiveness of individually tailored treatment and prevention policies known as adaptive or "just-in-time" behavioral interventions. The nature of these interventions requires assigning dosages at categorical levels, which has been addressed in prior work using Mixed Logical Dynamical (MLD)-based hybrid model predictive control (HMPC) schemes. However, certain requirements of adaptive behavioral interventions that involve sequential decision making have not been comprehensively explored in the literature. This paper presents an extension of the traditional MLD framework for HMPC by representing the requirements of sequential decision policies as mixed-integer linear constraints. This is accomplished with user-specified dosage sequence tables, manipulation of one input at a time, and a switching time strategy for assigning dosages at time intervals less frequent than the measurement sampling interval. A model developed for a gestational weight gain (GWG) intervention is used to illustrate the generation of these sequential decision policies and their effectiveness for implementing adaptive behavioral interventions involving multiple components.
Luo, Yuan; Szolovits, Peter
2016-01-01
In natural language processing, stand-off annotation uses the starting and ending positions of an annotation to anchor it to the text and stores the annotation content separately from the text. We address the fundamental problem of efficiently storing stand-off annotations when applying natural language processing on narrative clinical notes in electronic medical records (EMRs) and efficiently retrieving such annotations that satisfy position constraints. Efficient storage and retrieval of stand-off annotations can facilitate tasks such as mapping unstructured text to electronic medical record ontologies. We first formulate this problem into the interval query problem, for which optimal query/update time is in general logarithm. We next perform a tight time complexity analysis on the basic interval tree query algorithm and show its nonoptimality when being applied to a collection of 13 query types from Allen's interval algebra. We then study two closely related state-of-the-art interval query algorithms, proposed query reformulations, and augmentations to the second algorithm. Our proposed algorithm achieves logarithmic time stabbing-max query time complexity and solves the stabbing-interval query tasks on all of Allen's relations in logarithmic time, attaining the theoretic lower bound. Updating time is kept logarithmic and the space requirement is kept linear at the same time. We also discuss interval management in external memory models and higher dimensions.
Luo, Yuan; Szolovits, Peter
2016-01-01
In natural language processing, stand-off annotation uses the starting and ending positions of an annotation to anchor it to the text and stores the annotation content separately from the text. We address the fundamental problem of efficiently storing stand-off annotations when applying natural language processing on narrative clinical notes in electronic medical records (EMRs) and efficiently retrieving such annotations that satisfy position constraints. Efficient storage and retrieval of stand-off annotations can facilitate tasks such as mapping unstructured text to electronic medical record ontologies. We first formulate this problem into the interval query problem, for which optimal query/update time is in general logarithm. We next perform a tight time complexity analysis on the basic interval tree query algorithm and show its nonoptimality when being applied to a collection of 13 query types from Allen’s interval algebra. We then study two closely related state-of-the-art interval query algorithms, proposed query reformulations, and augmentations to the second algorithm. Our proposed algorithm achieves logarithmic time stabbing-max query time complexity and solves the stabbing-interval query tasks on all of Allen’s relations in logarithmic time, attaining the theoretic lower bound. Updating time is kept logarithmic and the space requirement is kept linear at the same time. We also discuss interval management in external memory models and higher dimensions. PMID:27478379
Kozak, Oksana V; Sukach, Georgiy G; Korchinskaya, Oksana I; Trembach, Alexander M; Turicina, Viktoria L; Voit, Natalia U
2005-06-01
To assess the correlations between the first 131I activity value, time interval between the courses of radioiodine treatment and the overall number of courses required for total destruction of lung metastases in patients with differentiated thyroid cancer with metastatic lesions in lungs. 27 patients with differentiated thyroid cancer with metastases in lungs have been treated with radioiodine after surgical intervention. Activities administered amounted from 1600 to 7980 MBq. The number of radioiodine courses before total ablation of all metastatic lesions amounted from 1 to 10. Time interval between the 1st and the 2nd courses amounted from 3.5 to 11.5 months (6 months in average). The regression analysis of the data has been made. The exponential model fits the actual number of courses as a function of the first-second activity value and time interval between the courses. The first activity has a decisive influence on the number of courses required for total metastases ablation. The greater was the first activity value, the lesser was the overall number of courses. Increasing time interval between 1st and 2nd courses to 10 months seems to result in reducing the number of courses. Nevertheless even in the case of high activities the probability to undergone less then 3 courses is low. According to the proposed model in thyroid cancer patients with metastases in lungs the first activity should be not lesser than 6000 MBq, time interval between treatments--approximately 10 months. The results of our study suggest that individual factors such as histology, the number and the size of metastases in lymph nodes could not contribute more to the final outcome than the treatment variables, namely the first-second activity and time interval, nor could they affect the hierarchy of the effects revealed for the treatment variables.
NASA Technical Reports Server (NTRS)
1975-01-01
The Proceedings contain the papers presented at the Seventh Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting and the edited record of the discussion period following each paper. This meeting provided a forum to promote more effective, efficient, economical and skillful applications of PTTI technology to the many problem areas to which PTTI offers solutions. Specifically the purpose of the meeting is to: disseminate, coordinate, and exchange practical information associated with precise time and frequency; acquaint systems engineers, technicians and managers with precise time and frequency technology and its applications; and review present and future requirements for PTTI.
Ti, Xiaonan; Tani, Naoki; Isobe, Minoru; Kai, Hidenori
2006-05-01
The TIME (Time Interval Measuring Enzyme) ATPase measures time intervals in accordance with diapause development, which indispensably requires cold for resumption of embryonic development in the silkworm (Bombyx mori). The PIN (Peptidyl Inhibitory Needle) peptide regulates the time measurement function of TIME. In the present study we investigated the interaction between TIME and PIN in order to address the mechanism of diapause development. When TIME was isolated from eggs later than 12 days after oviposition, transient bursts of ATPase activity occurred 18h after isolation of TIME, and the younger the eggs and pupal ovaries from which TIME was isolated, the earlier the bursts of ATPase activity appeared. However, no interval-timer activation of ATPase occurred in ovaries earlier than 6 days after pupation. Similar patterns of ATPase activity occurred in test tubes after mixing TIME with PIN. The shorter the time PIN was mixed with TIME, the earlier the ATPase activity appeared. The timer may be built into the protein conformation of TIME, and PIN (which is present in ovaries beginning 6 days after pupation) appears able to alter this timer conformation through pupal stages to laid eggs. We discuss the possible mechanism of diapause development in relation to the timer mechanism of TIME.
Chowdhury, Rezwan; Boyce, Andrew; Halperin, Ross
2015-01-01
Background: Lung cancer is associated with rapid disease progression, which can significantly progress over a duration of four to eight weeks. This study examines the time interval lung cancer patients from the interior of British Columbia (BC) experience while undergoing diagnostic evaluation, biopsy, staging, and preparation for treatment. Methods: A chart review of lung cancer patients (n=231) referred to the BC Cancer Agency Centre for the Southern Interior between January 1, 2010 and December 31, 2011 was performed. Time zero was defined as the date of the first abnormal chest imaging. Time intervals, expressed as median averages, to specialist consult, biopsy, oncologic referral, initial oncology consultation, and commencement of oncologic treatment were obtained. Results: The median time interval from first abnormal chest imaging to a specialist consultation was 18 days (interquartile range, IQR, 7-36). An additional nine days elapsed prior to biopsy in the form of bronchoscopy, CT-guided biopsy, or sputum cytology (median; IQR, 3-21); if lobectomy was required, 18 days elapsed (median; IQR, 9-28). Eight days were required for pathologic diagnosis and subsequent referral to the cancer centre (median; IQR, 3-16.5). Once referral was received, 10 days elapsed prior to consultation with either a medical or radiation oncologist (median, IQR 5-18). Finally, eight days was required for initiation of radiation and/or chemotherapy (median; IQR, 1-15). The median wait time from detection of lung cancer on imaging to oncologic treatment in the form of radiation and/or chemotherapy was 65.5 days (IQR, 41.5-104.3). Interpretation: Patients in the BC Southern Interior experience considerable delays in accessing lung cancer care. During this time, the disease has the potential to significantly progress and it is possible that a subset of patients may lose their opportunity for curative intent treatment. PMID:26543688
DOE Office of Scientific and Technical Information (OSTI.GOV)
Water, Steven van de, E-mail: s.vandewater@erasmusmc.nl; Valli, Lorella; Alma Mater Studiorum, Department of Physics and Astronomy, Bologna University, Bologna
Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was alsomore » varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.« less
Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M
2011-01-01
Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218
Human's choices in situations of time-based diminishing returns.
Hackenberg, T D; Axtell, S A
1993-01-01
Three experiments examined adult humans' choices in situations with contrasting short-term and long-term consequences. Subjects were given repeated choices between two time-based schedules of points exchangeable for money: a fixed schedule and a progressive schedule that began at 0 s and increased by 5 s with each point delivered by that schedule. Under "reset" conditions, choosing the fixed schedule not only produced a point but it also reset the requirements of the progressive schedule to 0 s. In the first two experiments, reset conditions alternated with "no-reset" conditions, in which progressive-schedule requirements were independent of fixed-schedule choices. Experiment 1 entailed choices between a progressive-interval schedule and a fixed-interval schedule, the duration of which varied across conditions. Switching from the progressive- to the fixed-interval schedule was systematically related to fixed-interval size in 4 of 8 subjects, and in all subjects occurred consistently sooner in the progressive-schedule sequence under reset than under no-reset procedures. The latter result was replicated in a second experiment, in which choices between progressive- and fixed-interval schedules were compared with choices between progressive- and fixed-time schedules. In Experiment 3, switching patterns under reset conditions were unrelated to variations in intertrial interval. In none of the experiments did orderly choice patterns depend on verbal descriptions of the contingencies or on schedule-controlled response patterns in the presence of the chosen schedules. The overall pattern of results indicates control of choices by temporarily remote consequences, and is consistent with versions of optimality theory that address performance in situations of diminishing returns. PMID:8315364
Holland, Alexander; Aboy, Mateo
2009-07-01
We present a novel method to iteratively calculate discrete Fourier transforms for discrete time signals with sample time intervals that may be widely nonuniform. The proposed recursive Fourier transform (RFT) does not require interpolation of the samples to uniform time intervals, and each iterative transform update of N frequencies has computational order N. Because of the inherent non-uniformity in the time between successive heart beats, an application particularly well suited for this transform is power spectral density (PSD) estimation for heart rate variability. We compare RFT based spectrum estimation with Lomb-Scargle Transform (LST) based estimation. PSD estimation based on the LST also does not require uniform time samples, but the LST has a computational order greater than Nlog(N). We conducted an assessment study involving the analysis of quasi-stationary signals with various levels of randomly missing heart beats. Our results indicate that the RFT leads to comparable estimation performance to the LST with significantly less computational overhead and complexity for applications requiring iterative spectrum estimations.
Hughes, Daniel; Nair, Sunil; Harvey, John N
2017-12-01
Objectives To determine the necessary screening interval for retinopathy in diabetic patients with no retinopathy based on time to laser therapy and to assess long-term visual outcome following screening. Methods In a population-based community screening programme in North Wales, 2917 patients were followed until death or for approximately 12 years. At screening, 2493 had no retinopathy; 424 had mostly minor degrees of non-proliferative retinopathy. Data on timing of first laser therapy and visual outcome following screening were obtained from local hospitals and ophthalmology units. Results Survival analysis showed that very few of the no retinopathy at screening group required laser therapy in the early years compared with the non-proliferative retinopathy group ( p < 0.001). After two years, <0.1% of the no retinopathy at screening group required laser therapy, and at three years 0.2% (cumulative), lower rates of treatment than have been suggested by analyses of sight-threatening retinopathy determined photographically. At follow-up (mean 7.8 ± 4.6 years), mild to moderate visual impairment in one or both eyes due to diabetic retinopathy was more common in those with retinopathy at screening (26% vs. 5%, p < 0.001), but blindness due to diabetes occurred in only 1 in 1000. Conclusions Optimum screening intervals should be determined from time to active treatment. Based on requirement for laser therapy, the screening interval for diabetic patients with no retinopathy can be extended to two to three years. Patients who attend for retinal screening and treatment who have no or non-proliferative retinopathy now have a very low risk of eventual blindness from diabetes.
Precise time technology for selected Air Force systems: Present status and future requirements
NASA Technical Reports Server (NTRS)
Yannoni, N. F.
1981-01-01
Precise time and time interval (PTTI) technology is becoming increasingly significant to Air Force operations as digital techniques find expanded utility in military missions. Timing has a key role in the function as well as in navigation. A survey of the PTTI needs of several Air Force systems is presented. Current technology supporting these needs was reviewed and new requirements are emphasized for systems as they transfer from initial development to final operational deployment.
76 FR 61476 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-04
... locking; and 236.109, Time releases, timing relays and timing devices; on vital microprocessor-based... microprocessor-based locking systems. These tests, at this interval, would replace the tests currently required... listed in Exhibit B. 2. All future purchases of microprocessor-controlled interlocking locations. 3...
Sanabria, Federico; Killeen, Peter R
2008-01-01
Background The inability to inhibit reinforced responses is a defining feature of ADHD associated with impulsivity. The Spontaneously Hypertensive Rat (SHR) has been extolled as an animal model of ADHD, but there is no clear experimental evidence of inhibition deficits in SHR. Attempts to demonstrate these deficits may have suffered from methodological and analytical limitations. Methods We provide a rationale for using two complementary response-withholding tasks to doubly dissociate impulsivity from motivational and motor processes. In the lever-holding task (LHT), continual lever depression was required for a minimum interval. Under a differential reinforcement of low rates schedule (DRL), a minimum interval was required between lever presses. Both tasks were studied using SHR and two normotensive control strains, Wistar-Kyoto (WKY) and Long Evans (LE), over an overlapping range of intervals (1 – 5 s for LHT and 5 – 60 s for DRL). Lever-holding and DRL performance was characterized as the output of a mixture of two processes, timing and iterative random responding; we call this account of response inhibition the Temporal Regulation (TR) model. In the context of TR, impulsivity was defined as a bias toward premature termination of the timed intervals. Results The TR model provided an accurate description of LHT and DRL performance. On the basis of TR parameter estimates, SHRs were more impulsive than LE rats across tasks and target times. WKY rats produced substantially shorter timed responses in the lever-holding task than in DRL, suggesting a motivational or motor deficit. The precision of timing by SHR, as measured by the variance of their timed intervals, was excellent, flouting expectations from ADHD research. Conclusion This research validates the TR model of response inhibition and supports SHR as an animal model of ADHD-related impulsivity. It indicates, however, that SHR's impulse-control deficit is not caused by imprecise timing. The use of ad hoc impulsivity metrics and of WKY as control strain for SHR impulsivity are called into question. PMID:18261220
Next Steps in Network Time Synchronization For Navy Shipboard Applications
2008-12-01
40th Annual Precise Time and Time Interval (PTTI) Meeting NEXT STEPS IN NETWORK TIME SYNCHRONIZATION FOR NAVY SHIPBOARD APPLICATIONS...dynamic manner than in previous designs. This new paradigm creates significant network time synchronization challenges. The Navy has been...deploying the Network Time Protocol (NTP) in shipboard computing infrastructures to meet the current network time synchronization requirements
Brackney, Ryan J; Cheung, Timothy H. C; Neisewander, Janet L; Sanabria, Federico
2011-01-01
Dissociating motoric and motivational effects of pharmacological manipulations on operant behavior is a substantial challenge. To address this problem, we applied a response-bout analysis to data from rats trained to lever press for sucrose on variable-interval (VI) schedules of reinforcement. Motoric, motivational, and schedule factors (effort requirement, deprivation level, and schedule requirements, respectively) were manipulated. Bout analysis found that interresponse times (IRTs) were described by a mixture of two exponential distributions, one characterizing IRTs within response bouts, another characterizing intervals between bouts. Increasing effort requirement lengthened the shortest IRT (the refractory period between responses). Adding a ratio requirement increased the length and density of response bouts. Both manipulations also decreased the bout-initiation rate. In contrast, food deprivation only increased the bout-initiation rate. Changes in the distribution of IRTs over time showed that responses during extinction were also emitted in bouts, and that the decrease in response rate was primarily due to progressively longer intervals between bouts. Taken together, these results suggest that changes in the refractory period indicate motoric effects, whereas selective alterations in bout initiation rate indicate incentive-motivational effects. These findings support the use of response-bout analyses to identify the influence of pharmacological manipulations on processes underlying operant performance. PMID:21765544
Military Applicability of Interval Training for Health and Performance.
Gibala, Martin J; Gagnon, Patrick J; Nindl, Bradley C
2015-11-01
Militaries from around the globe have predominantly used endurance training as their primary mode of aerobic physical conditioning, with historical emphasis placed on the long distance run. In contrast to this traditional exercise approach to training, interval training is characterized by brief, intermittent bouts of intense exercise, separated by periods of lower intensity exercise or rest for recovery. Although hardly a novel concept, research over the past decade has shed new light on the potency of interval training to elicit physiological adaptations in a time-efficient manner. This work has largely focused on the benefits of low-volume interval training, which involves a relatively small total amount of exercise, as compared with the traditional high-volume approach to training historically favored by militaries. Studies that have directly compared interval and moderate-intensity continuous training have shown similar improvements in cardiorespiratory fitness and the capacity for aerobic energy metabolism, despite large differences in total exercise and training time commitment. Interval training can also be applied in a calisthenics manner to improve cardiorespiratory fitness and strength, and this approach could easily be incorporated into a military conditioning environment. Although interval training can elicit physiological changes in men and women, the potential for sex-specific adaptations in the adaptive response to interval training warrants further investigation. Additional work is needed to clarify adaptations occurring over the longer term; however, interval training deserves consideration from a military applicability standpoint as a time-efficient training strategy to enhance soldier health and performance. There is value for military leaders in identifying strategies that reduce the time required for exercise, but nonetheless provide an effective training stimulus.
The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients
2010-01-01
Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440
Single photon detection and timing in the Lunar Laser Ranging Experiment.
NASA Technical Reports Server (NTRS)
Poultney, S. K.
1972-01-01
The goals of the Lunar Laser Ranging Experiment lead to the need for the measurement of a 2.5 sec time interval to an accuracy of a nanosecond or better. The systems analysis which included practical retroreflector arrays, available laser systems, and large telescopes led to the necessity of single photon detection. Operation under all background illumination conditions required auxiliary range gates and extremely narrow spectral and spatial filters in addition to the effective gate provided by the time resolution. Nanosecond timing precision at relatively high detection efficiency was obtained using the RCA C31000F photomultiplier and Ortec 270 constant fraction of pulse-height timing discriminator. The timing accuracy over the 2.5 sec interval was obtained using a digital interval with analog vernier ends. Both precision and accuracy are currently checked internally using a triggerable, nanosecond light pulser. Future measurements using sub-nanosecond laser pulses will be limited by the time resolution of single photon detectors.
Evaluation of a Tool for Airborne-Managed In-Trail Approach Spacing
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Lohr, Gary W.; Abbott, Terence S.; Nadler, Eric D.; Eischeid, Todd
2005-01-01
The Advanced Terminal Area Approach Spacing (ATAAS) tool uses Automatic Dependent Surveillance-Broadcast aircraft state data to compute a speed command for an ATAAS-equipped aircraft to follow and obtain a required time interval behind another aircraft. The ATAAS tool and candidate operational procedures were tested in a high-fidelity, full mission simulator with active airline subject pilots flying an arrival scenario to obtain pilot perceptions of acceptability and workload for the concept. The aircraft consistently achieved the target spacing interval within 1 s when the ATAAS speed guidance was autothrottle-coupled and a slightly greater (4 - 5 s) but consistent interval with pilot-controlled speed changes. The subject pilots rated the ATAAS workload as similar to one with standard procedures for a nominal Instrument Landing System (ILS) approach. They also rated highly various procedural aspects (including amount of head-down time required). Eyetracker data showed only slight changes in instrument scan patterns for ATAAS versus standard ILS procedures.
More reliable protein NMR peak assignment via improved 2-interval scheduling.
Chen, Zhi-Zhong; Lin, Guohui; Rizzi, Romeo; Wen, Jianjun; Xu, Dong; Xu, Ying; Jiang, Tao
2005-03-01
Protein NMR peak assignment refers to the process of assigning a group of "spin systems" obtained experimentally to a protein sequence of amino acids. The automation of this process is still an unsolved and challenging problem in NMR protein structure determination. Recently, protein NMR peak assignment has been formulated as an interval scheduling problem (ISP), where a protein sequence P of amino acids is viewed as a discrete time interval I (the amino acids on P one-to-one correspond to the time units of I), each subset S of spin systems that are known to originate from consecutive amino acids from P is viewed as a "job" j(s), the preference of assigning S to a subsequence P of consecutive amino acids on P is viewed as the profit of executing job j(s) in the subinterval of I corresponding to P, and the goal is to maximize the total profit of executing the jobs (on a single machine) during I. The interval scheduling problem is max SNP-hard in general; but in the real practice of protein NMR peak assignment, each job j(s) usually requires at most 10 consecutive time units, and typically the jobs that require one or two consecutive time units are the most difficult to assign/schedule. In order to solve these most difficult assignments, we present an efficient 13/7-approximation algorithm for the special case of the interval scheduling problem where each job takes one or two consecutive time units. Combining this algorithm with a greedy filtering strategy for handling long jobs (i.e., jobs that need more than two consecutive time units), we obtain a new efficient heuristic for protein NMR peak assignment. Our experimental study shows that the new heuristic produces the best peak assignment in most of the cases, compared with the NMR peak assignment algorithms in the recent literature. The above algorithm is also the first approximation algorithm for a nontrivial case of the well-known interval scheduling problem that breaks the ratio 2 barrier.
Nondestructive test determines overload destruction characteristics of current limiter fuses
NASA Technical Reports Server (NTRS)
Swartz, G. A.
1968-01-01
Nondestructive test predicts the time required for current limiters to blow /open the circuit/ when subjected to a given overload. The test method is based on an empirical relationship between the voltage rise across a current limiter for a fixed time interval and the time to blow.
Undermatching and overmatching: The fixed-ratio changeover requirement
Pliskoff, Stanley S.; Fetterman, J. Gregor
1981-01-01
Concurrent variable-interval two-minute and six-minute schedules were arranged while the fixed-ratio changeover requirement was varied among one, two, and four responses. A four-response requirement produced overmatching in the response and time data. A one-response requirement produced consistent undermatching in the time data but mixed results in the response data. The two-response requirement showed undermatching in the time data and overmatching in the response data. The results are discussed in relation to previous research using changeover requirements of five and ten responses, which produced clear tendencies toward overmatching, especially with response data. Taken together, these findings suggest that matching is not a unique result, and that undermatching or overmatching can be produced by continuous variation of the changeover requirements. PMID:16812229
Patient-specific Distraction Regimen to Avoid Growth-rod Failure.
Agarwal, Aakash; Jayaswal, Arvind; Goel, Vijay K; Agarwal, Anand K
2018-02-15
A finite element study to establish the relationship between patient's curve flexibility (determined using curve correction under gravity) in juvenile idiopathic scoliosis and the required distraction frequency to avoid growth rod fracture, as a function of time. To perform a parametric analysis using a juvenile scoliotic spine model (single mid-thoracic curve with the apex at the eighth thoracic vertebra) and establish the relationship between curve flexibility (determined using curve correction under gravity) and the distraction interval that allows a higher factor of safety for the growth rods. Previous studies have shown that frequent distraction with smaller magnitude of distractions are less likely to result in rod failure. However there has not been any methodology or a chart provided to apply this knowledge on to the individual patients that undergo the treatment. This study aims to fill in that gap. The parametric study was performed by varying the material properties of the disc, hence altering the axial stiffness of the scoliotic spine model. The stresses on the rod were found to increase with increased axial stiffness of the spine, and this resulted in the increase of required optimal frequency to achieve a factor of safety of two for growth rods. A relationship between the percentage correction in Cobb's angle due to gravity alone, and the required distraction interval for limiting the maximum von Mises stress to 255 MPa on the growth rods was established. The distraction interval required to limit the stresses to the selected nominal value reduces with increase in stiffness of the spine. Furthermore, the appropriate distraction interval reduces for each model as the spine becomes stiffer with time (autofusion). This points to the fact the optimal distraction frequency is a time-dependent variable that must be achieved to keep the maximum von Mises stress under the specified factor of safety. The current study demonstrates the possibility of translating fundamental information from finite element modeling to the clinical arena, for mitigating the occurrence of growth rod fracture, that is, establishing a relationship between optimal distraction interval and curve flexibility (determined using curve correction under gravity). N/A.
Evaluation of the concept of pressure proof testing fuselage structures
NASA Technical Reports Server (NTRS)
Harris, Charles E.; Orringer, Oscar
1991-01-01
The FAA and NASA have recently completed independent technical evaluations of the concept of pressure proof testing the fuselage of commercial transport airplanes. The results of these evaluations are summarized. The objectives of the evaluations were to establish the potential benefit of the pressure proof test, to quantify the most desirable proof test pressure, and to quantify the required proof test interval. The focus of the evaluations was on multiple-site cracks extending from adjacent rivet holes of a typical fuselage longitudinal lap splice joint. The FAA and NASA do not support pressure proof testing the fuselage of aging commercial transport aircraft. The argument against proof testing is as follows: (1) a single proof test does not insure an indefinite life; therefore, the proof test must be repeated at regular intervals; (2) for a proof factor of 1.33, the required proof test interval must be below 300 flights to account for uncertainties in the evaluation; (3) conducting the proof test at a proof factor of 1.5 would considerably exceed the fuselage design limit load; therefore, it is not consistent with accepted safe practices; and (4) better safety can be assured by implementing enhanced nondestructive inspection requirements, and adequate reliability can be achieved by an inspection interval several times longer than the proof test interval.
van de Venter, Ec; Oliver, I; Stuart, J M
2015-02-12
Timely outbreak investigations are central in containing communicable disease outbreaks; despite this, no guidance currently exists on expectations of timeliness for investigations. A literature review was conducted to assess the length of epidemiological outbreak investigations in Europe in peer-reviewed publications. We determined time intervals between outbreak declaration to hypothesis generation, and hypothesis generation to availability of results from an analytical study. Outbreaks were classified into two groups: those with a public health impact across regions within a country and requiring national coordination (level 3) and those with a severe or catastrophic impact requiring direction at national level (levels 4 and 5). Investigations in Europe published between 2003 and 2013 were reviewed. We identified 86 papers for review: 63 level 3 and 23 level 4 and 5 investigations. Time intervals were ascertained from 55 papers. The median period for completion of an analytical study was 15 days (range: 4-32) for levels 4 and 5 and 31 days (range: 9-213) for level 3 investigations. Key factors influencing the speed of completing analytical studies were outbreak level, severity of infection and study design. Our findings suggest that guidance for completing analytical studies could usefully be provided, with different time intervals according to outbreak severity.
Hackenberg, T D; Hineline, P N
1992-01-01
Pigeons chose between two schedules of food presentation, a fixed-interval schedule and a progressive-interval schedule that began at 0 s and increased by 20 s with each food delivery provided by that schedule. Choosing one schedule disabled the alternate schedule and stimuli until the requirements of the chosen schedule were satisfied, at which point both schedules were again made available. Fixed-interval duration remained constant within individual sessions but varied across conditions. Under reset conditions, completing the fixed-interval schedule not only produced food but also reset the progressive interval to its minimum. Blocks of sessions under the reset procedure were interspersed with sessions under a no-reset procedure, in which the progressive schedule value increased independent of fixed-interval choices. Median points of switching from the progressive to the fixed schedule varied systematically with fixed-interval value, and were consistently lower during reset than during no-reset conditions. Under the latter, each subject's choices of the progressive-interval schedule persisted beyond the point at which its requirements equaled those of the fixed-interval schedule at all but the highest fixed-interval value. Under the reset procedure, switching occurred at or prior to that equality point. These results qualitatively confirm molar analyses of schedule preference and some versions of optimality theory, but they are more adequately characterized by a model of schedule preference based on the cumulated values of multiple reinforcers, weighted in inverse proportion to the delay between the choice and each successive reinforcer. PMID:1548449
Frequent plateletpheresis does not clinically significantly decrease platelet counts in donors.
Katz, Louis; Palmer, Kim; McDonnell, Emily; Kabat, Andy
2007-09-01
In October 2005, the US Food and Drug Administration (FDA) issued draft guidance on collecting platelets (PLTs) by automated methods. The FDA proposed limiting collections to 24 components, rather than 24 procedures, annually with up to 3 components per procedure. The rationale was from literature suggesting frequent PLT collection resulted in significant declines in donor PLT counts. Additional requirements for minimal interdonation intervals were proposed. Plateletpheresis records at a regional blood center with predonation PLT counts were used to assess the impact of the restriction on PLT collections. They were reviewed to demonstrate the effects of collection frequency, number of products collected, and interdonation interval on donor PLT counts. Total protein and albumin levels were compared in a subset of 24-times-per-year PLT donors and control whole-blood donors. A limit of 24 components would require replacement of approximately 20 percent of the donor base to recover lost components. No clinically important decrease in PLT counts before donation was seen in donors donating multiple PLT components up to 24 times per year, regardless of interdonation interval. No frequent donor was deferred for a PLT count less than 150 x 10(9) per L. Short interdonation intervals were associated with statistically but not clinically important decreases in PLT counts. Protein levels were not distinguishable between PLT donors and controls. The proposed restrictions are not required to prevent thrombocytopenia in frequent PLT donors and would adversely impact the supply of apheresis PLTs. Protein levels are maintained in these high-frequency donors.
Time-dependent influence of sensorimotor set on automatic responses in perturbed stance
NASA Technical Reports Server (NTRS)
Chong, R. K.; Horak, F. B.; Woollacott, M. H.; Peterson, B. W. (Principal Investigator)
1999-01-01
These experiments tested the hypothesis that the ability to change sensorimotor set quickly for automatic responses depends on the time interval between successive surface perturbations. Sensorimotor set refers to the influence of prior experience or context on the state of the sensorimotor system. Sensorimotor set for postural responses was influenced by first giving subjects a block of identical backward translations of the support surface, causing forward sway and automatic gastrocnemius responses. The ability to change set quickly was inferred by measuring the suppression of the stretched antagonist gastrocnemius responses to toes-up rotations causing backward sway, following the translations. Responses were examined under short (10-14 s) and long (19-24 s) inter-trial intervals in young healthy subjects. The results showed that subjects in the long-interval group changed set immediately by suppressing gastrocnemius to 51% of translation responses within the first rotation and continued to suppress them over succeeding rotations. In contrast, subjects in the short-interval group did not change set immediately, but required two or more rotations to suppress gastrocnemius responses. By the last rotation, the short-interval group suppressed gastrocnemius responses to 33%, similar to the long-interval group of 29%. Associated surface plantarflexor torque resulting from these responses showed similar results. When rotation and translation perturbations alternated, however, the short-interval group was not able to suppress gastrocnemius responses to rotations as much as the long-interval group, although they did suppress more than in the first rotation trial after a series of translations. Set for automatic responses appears to linger, from one trial to the next. Specifically, sensorimotor set is more difficult to change when surface perturbations are given in close succession, making it appear as if set has become progressively stronger. A strong set does not mean that responses become larger over consecutive trials. Rather, it is inferred by the extent of difficulty in changing a response when it is appropriate to do so. These results suggest that the ability to change sensorimotor set quickly is sensitive to whether the change is required after a long or a short series of a prior different response, which in turn depends on the time interval between successive trials. Different rate of gastrocnemius suppression to toes-up rotation of the support surface have been reported in previous studies. This may be partially explained by different inter-trial time intervals demonstrated in this study.
Romkema, Sietske; Bongers, Raoul M; van der Sluis, Corry K
2015-01-01
Improvement in prosthetic training using intermanual transfer (the transfer of motor skills from the trained, “unaffected” hand to the untrained, “affected” hand) has been shown in previous studies. The aim of this study is to determine the influence of the inter-training interval on the magnitude of the intermanual transfer effects. This was done using a mechanistic, randomized, single-blinded pretest-posttest design. Sixty-four able-bodied, right-handed participants were randomly assigned to the Short and Long Interval Training Groups and the Short and Long Interval Control Groups. The Short and Long Interval Training Groups used a prosthesis simulator in their training program. The Short and Long Interval Control Groups executed a sham training program, that is, a dummy training program in which the same muscles were trained as with the prosthesis simulator. The Short Interval Training Group and the Short Interval Control Groups trained on consecutive days, while the Long Interval Training Group and Long Interval Control Group trained twice a week. To determine the improvement in skills, a test was administered before, immediately after, and at two points in time after the training. Training was performed with the “unaffected” arm; tests were performed with the “affected” arm. The outcome measurements were: the movement time (the time from the beginning of the movement until completion of the task); the duration of maximum hand opening, (the opening of the prosthetic hand while grasping an object); and the grip-force control (the error from the required grip-force during a tracking task). Intermanual transfer was found in movement times, but not in hand opening or grip-force control. The length of the inter-training interval did not affect the magnitude of intermanual transfer effects. No difference in the intermanual transfer effect in upper-limb prosthesis training was found for training on a daily basis as compared to training twice a week. Nederlands Trial Register NTR3888.
Romkema, Sietske; Bongers, Raoul M.; van der Sluis, Corry K.
2015-01-01
Improvement in prosthetic training using intermanual transfer (the transfer of motor skills from the trained, “unaffected” hand to the untrained, “affected” hand) has been shown in previous studies. The aim of this study is to determine the influence of the inter-training interval on the magnitude of the intermanual transfer effects. This was done using a mechanistic, randomized, single-blinded pretest-posttest design. Sixty-four able-bodied, right-handed participants were randomly assigned to the Short and Long Interval Training Groups and the Short and Long Interval Control Groups. The Short and Long Interval Training Groups used a prosthesis simulator in their training program. The Short and Long Interval Control Groups executed a sham training program, that is, a dummy training program in which the same muscles were trained as with the prosthesis simulator. The Short Interval Training Group and the Short Interval Control Groups trained on consecutive days, while the Long Interval Training Group and Long Interval Control Group trained twice a week. To determine the improvement in skills, a test was administered before, immediately after, and at two points in time after the training. Training was performed with the “unaffected” arm; tests were performed with the “affected” arm. The outcome measurements were: the movement time (the time from the beginning of the movement until completion of the task); the duration of maximum hand opening, (the opening of the prosthetic hand while grasping an object); and the grip-force control (the error from the required grip-force during a tracking task). Intermanual transfer was found in movement times, but not in hand opening or grip-force control. The length of the inter-training interval did not affect the magnitude of intermanual transfer effects. No difference in the intermanual transfer effect in upper-limb prosthesis training was found for training on a daily basis as compared to training twice a week. Trial Registration Nederlands Trial Register NTR3888 PMID:26075396
1980-01-01
specified condition. 10. Mean-Time-Between-Maintenance ( MTDM ). The mean of the distribution of the time intervals between all maintenance actions...which requires unscheduled maint. action. 3. MTDM : Mean-Time-Between-Maintenance. 4. W4I/OH: Maint Man-Hour/Engine Opbrating Hour S. CLASS III FAIURE
Psychophysical Assessment of Timing in Individuals with Autism
ERIC Educational Resources Information Center
Allman, Melissa J.; DeLeon, Iser G.
2011-01-01
Perception of time, in the seconds to minutes range, is not well characterized in autism. The required interval timing system (ITS) develops at the same stages during infancy as communication, social reciprocity, and other cognitive and behavioral functions. The authors used two versions of a temporal bisection procedure to study the perception of…
Modulation of Response Timing in ADHD, Effects of Reinforcement Valence and Magnitude
ERIC Educational Resources Information Center
Luman, Marjolein; Oosterlaan, Jaap; Sergeant, Joseph A.
2008-01-01
The present study investigated the impact of reinforcement valence and magnitude on response timing in children with ADHD. Children were required to estimate a 1-s interval, and both the median response time (response tendency) and the intrasubject-variability (response stability) were investigated. In addition, heart rate and skin conductance…
Versatile all-digital time interval measuring system
NASA Astrophysics Data System (ADS)
Vyhlidal, David; Cech, Miroslav
2011-06-01
This paper describes a design and performance of a versatile all-digital time interval measuring system. The measurement method is based on an interpolation principle. In this principle the time interval is first roughly digitized by a coarse counter driven by a high stability reference clock and the fractions between the clock periods are measured by two Time-to-Digital Converter chips TDC-GPX manufactured by Acam messelectronic. Control circuits allow programmable customization of the system to satisfy many applications such as laser range finding, event counting, or time-of-flight measurements in various physics experiments. The system has two reference clocks inputs and two independent channels for measuring start and stop events. Only one 40 MHz reference is required for the measurement. The second reference can be, for example, 1 PPS (Pulse per Second) signal from a GPS (Global Positioning System) to time tag events. Time intervals are measured using the highest resolution mode of the TDC-GPX chips. The resolution of each chip is software programmable and is PLL (Phase Locked Loop) stabilized against temperature and voltage variations. The system can achieve a timing resolution better than 15 ps rms with up to 90 kHz repetition rate. The time interval measurement range is from 0 ps up to 1 second. The power consumption of the whole system is 18 W including an embedded computer board and an LCD (Liquid Crystal Display) screen. The embedded computer controls the whole system, collects and evaluates measurement data and with the display provides a user interface. The system is implemented using commercially available components.
Outcome-Dependent Sampling with Interval-Censored Failure Time Data
Zhou, Qingning; Cai, Jianwen; Zhou, Haibo
2017-01-01
Summary Epidemiologic studies and disease prevention trials often seek to relate an exposure variable to a failure time that suffers from interval-censoring. When the failure rate is low and the time intervals are wide, a large cohort is often required so as to yield reliable precision on the exposure-failure-time relationship. However, large cohort studies with simple random sampling could be prohibitive for investigators with a limited budget, especially when the exposure variables are expensive to obtain. Alternative cost-effective sampling designs and inference procedures are therefore desirable. We propose an outcome-dependent sampling (ODS) design with interval-censored failure time data, where we enrich the observed sample by selectively including certain more informative failure subjects. We develop a novel sieve semiparametric maximum empirical likelihood approach for fitting the proportional hazards model to data from the proposed interval-censoring ODS design. This approach employs the empirical likelihood and sieve methods to deal with the infinite-dimensional nuisance parameters, which greatly reduces the dimensionality of the estimation problem and eases the computation difficulty. The consistency and asymptotic normality of the resulting regression parameter estimator are established. The results from our extensive simulation study show that the proposed design and method works well for practical situations and is more efficient than the alternative designs and competing approaches. An example from the Atherosclerosis Risk in Communities (ARIC) study is provided for illustration. PMID:28771664
Temporal properties of compensation for positive and negative spectacle lenses in chicks.
Zhu, Xiaoying; Wallman, Josh
2009-01-01
Chicks' eyes rapidly compensate for defocus imposed by spectacle lenses by changing their rate of elongation and their choroidal thickness. Compensation may involve internal emmetropization signals that rise and become saturated during episodes of lens wear and decline between episodes. The time constants of these signals were measured indirectly by measuring the magnitude of lens compensation in refractive error and ocular dimensions as a function of the duration of episodes and the intervals between the episodes. First, in a study of how quickly the signals rose, chicks were subjected to episodes of lens-wear of various durations (darkness otherwise), and the duration required to cause a half-maximum effect (rise-time) was estimated. Second, in a study of how quickly the signals declined, various dark intervals were imposed between episodes of lens-wear, and the interval required to reduce the maximum effect by half (fall-time) was estimated. The rise-times for the rate of ocular elongation and choroidal thickness were approximately 3 minutes for positive and negative lenses. The fall-times had a broad range of time courses: Positive lenses caused an enduring inhibition of ocular elongation with a fall-time of 24 hours. In contrast, negative lenses caused a transient stimulation of ocular elongation with a fall-time of 0.4 hour. The effects of episodes of defocus rise rapidly with episode duration to an asymptote and decline between episodes, with the time course depending strongly on the sign of defocus and the ocular component. The complex etiology of human myopia may reflect these temporal properties.
Odometers for Rail Application
DOT National Transportation Integrated Search
1975-05-01
Available mileage counters were evaluated, anticipating the possibility of using mileage intervals, rather than elapsed time, for freight car inspection. Simple, reliable and reasonably low costing devices were required. Only two unpowered mileage co...
Zhou, Zhenghua; Diao, Qinqin; Shao, Nan; Liang, Youke; Lin, Li; Lei, Yan; Zheng, Lingmei
2015-01-01
To conduct an analysis of the frequency of unhealthy food advertising on mainland Chinese television (TV) and children and adolescents' risk of exposure to them. The frequencies of all types of advertisements (ads) on forty TV channels in mainland China, the exact ad broadcast times, and the name and brand of all snacks and western fast foods advertised were recorded from 0800 hours to 2400 hours on both a weekday and a weekend day in a week. The difference in the frequencies of the diverse types of ads over eight time intervals (each time interval was 2 hours) were compared, and the trends in ad frequencies during the time intervals were described. The TV channels broadcast 155 (91-183) (expressed as median [P25-P75]) food ads, 87 (38-123) snack ads, 49 (11-85) beverage ads, and 58 (25-76) ads of snacks suitable for limited consumption (SSLCs) in a day. The proportion of snack ads among food ads (SPF%) was 55.5% (40.3%-71.0%), and the proportion of SSLC ads among snack ads (LPS%) was 67.4% (55.4%-79.3%). The ad frequencies for food, snacks, SSLCs, and beverages demonstrated significant differences among the eight time intervals (all P=0.000). TV channels broadcast the most frequent ads for food, snacks, SSLCs, and beverages during the time interval from 2000 hours to 2200 hours among the eight time intervals. Chinese children and adolescents may be at a high risk of exposure to unhealthy food advertising on TV. Reducing the exposure risk strongly requires multisectoral cooperation.
Zhou, Zhenghua; Diao, Qinqin; Shao, Nan; Liang, Youke; Lin, Li; Lei, Yan; Zheng, Lingmei
2015-01-01
Objective To conduct an analysis of the frequency of unhealthy food advertising on mainland Chinese television (TV) and children and adolescents’ risk of exposure to them. Methods The frequencies of all types of advertisements (ads) on forty TV channels in mainland China, the exact ad broadcast times, and the name and brand of all snacks and western fast foods advertised were recorded from 0800 hours to 2400 hours on both a weekday and a weekend day in a week. The difference in the frequencies of the diverse types of ads over eight time intervals (each time interval was 2 hours) were compared, and the trends in ad frequencies during the time intervals were described. Results The TV channels broadcast 155 (91-183) (expressed as median [P 25-P 75]) food ads, 87 (38-123) snack ads, 49 (11-85) beverage ads, and 58 (25-76) ads of snacks suitable for limited consumption (SSLCs) in a day. The proportion of snack ads among food ads (SPF%) was 55.5% (40.3%-71.0%), and the proportion of SSLC ads among snack ads (LPS%) was 67.4% (55.4%-79.3%). The ad frequencies for food, snacks, SSLCs, and beverages demonstrated significant differences among the eight time intervals (all P=0.000). TV channels broadcast the most frequent ads for food, snacks, SSLCs, and beverages during the time interval from 2000 hours to 2200 hours among the eight time intervals. Conclusions Chinese children and adolescents may be at a high risk of exposure to unhealthy food advertising on TV. Reducing the exposure risk strongly requires multisectoral cooperation. PMID:26133984
Temporal Integration of Auditory Information Is Invariant to Temporal Grouping Cues
Liu, Andrew S K; Tsunada, Joji; Gold, Joshua I; Cohen, Yale E
2015-01-01
Auditory perception depends on the temporal structure of incoming acoustic stimuli. Here, we examined whether a temporal manipulation that affects the perceptual grouping also affects the time dependence of decisions regarding those stimuli. We designed a novel discrimination task that required human listeners to decide whether a sequence of tone bursts was increasing or decreasing in frequency. We manipulated temporal perceptual-grouping cues by changing the time interval between the tone bursts, which led to listeners hearing the sequences as a single sound for short intervals or discrete sounds for longer intervals. Despite these strong perceptual differences, this manipulation did not affect the efficiency of how auditory information was integrated over time to form a decision. Instead, the grouping manipulation affected subjects' speed-accuracy trade-offs. These results indicate that the temporal dynamics of evidence accumulation for auditory perceptual decisions can be invariant to manipulations that affect the perceptual grouping of the evidence.
How to Handle a Satellite Change in an Operational TWSTFT Network?
2010-11-01
42 nd Annual Precise Time and Time Interval (PTTI) Meeting 285 HOW TO HANDLE A SATELLITE CHANGE IN AN OPERATIONAL TWSTFT NETWORK...way satellite time and frequency transfer ( TWSTFT ) is a powerful technique because of its real-time capabilities. In principle, the time difference...between remote clocks is almost instantaneously known after a measurement session. Long-term TWSTFT operations have required changes between
The determination of the pulse pile-up reject (PUR) counting for X and gamma ray spectrometry
NASA Astrophysics Data System (ADS)
Karabıdak, S. M.; Kaya, S.
2017-02-01
The collection the charged particles produced by the incident radiation on a detector requires a time interval. If this time interval is not sufficiently short compared with the peaking time of the amplifier, a loss in the recovered signal amplitude occurs. Another major constraint on the throughput of modern x or gamma-ray spectrometers is the time required for the subsequent the pulse processing by the electronics. Two above-mentioned limitations are cause of counting losses resulting from the dead time and the pile-up. The pulse pile-up is a common problem in x and gamma ray radiation detection systems. The pulses pile-up in spectroscopic analysis can cause significant errors. Therefore, inhibition of these pulses is a vital step. A way to reduce errors due to the pulse pile-up is a pile-up inspection circuitry (PUR). Such a circuit rejects some of the pulse pile-up. Therefore, this circuit leads to counting losses. Determination of these counting losses is an important problem. In this work, a new method is suggested for the determination of the pulse pile-up reject.
Pant, Jeevan K; Krishnan, Sridhar
2016-07-01
A new signal reconstruction algorithm for compressive sensing based on the minimization of a pseudonorm which promotes block-sparse structure on the first-order difference of the signal is proposed. Involved optimization is carried out by using a sequential version of Fletcher-Reeves' conjugate-gradient algorithm, and the line search is based on Banach's fixed-point theorem. The algorithm is suitable for the reconstruction of foot gait signals which admit block-sparse structure on the first-order difference. An additional algorithm for the estimation of stride-interval, swing-interval, and stance-interval time series from the reconstructed foot gait signals is also proposed. This algorithm is based on finding zero crossing indices of the foot gait signal and using the resulting indices for the computation of time series. Extensive simulation results demonstrate that the proposed signal reconstruction algorithm yields improved signal-to-noise ratio and requires significantly reduced computational effort relative to several competing algorithms over a wide range of compression ratio. For a compression ratio in the range from 88% to 94%, the proposed algorithm is found to offer improved accuracy for the estimation of clinically relevant time-series parameters, namely, the mean value, variance, and spectral index of stride-interval, stance-interval, and swing-interval time series, relative to its nearest competitor algorithm. The improvement in performance for compression ratio as high as 94% indicates that the proposed algorithms would be useful for designing compressive sensing-based systems for long-term telemonitoring of human gait signals.
A novel implementation of homodyne time interval analysis method for primary vibration calibration
NASA Astrophysics Data System (ADS)
Sun, Qiao; Zhou, Ling; Cai, Chenguang; Hu, Hongbo
2011-12-01
In this paper, the shortcomings and their causes of the conventional homodyne time interval analysis (TIA) method is described with respect to its software algorithm and hardware implementation, based on which a simplified TIA method is proposed with the help of virtual instrument technology. Equipped with an ordinary Michelson interferometer and dual channel synchronous data acquisition card, the primary vibration calibration system using the simplified method can perform measurements of complex sensitivity of accelerometers accurately, meeting the uncertainty requirements laid down in pertaining ISO standard. The validity and accuracy of the simplified TIA method is verified by simulation and comparison experiments with its performance analyzed. This simplified method is recommended to apply in national metrology institute of developing countries and industrial primary vibration calibration labs for its simplified algorithm and low requirements on hardware.
Postextrasystolic potentiation and contractile reserve: requirements and restrictions.
Lust, R M; Lutherer, L O; Gardner, M E; Cooper, M W
1982-12-01
These studies were conducted to examine the basic characteristics of postextrasystolic potentiation (PESP) and the relationship of loading effects to PESP. Measurements of left ventricular (LV) and aortic pressures, the rate of pressure rise, and echocardiographically determined LV dimensions were made in anesthetized open-chest dogs. The hearts were paced, and timed extrasystoles were introduced that were followed by postextrasystoles (PES). PES's were elicited after an interval equal to either a full compensatory pause or a time when the diastolic properties of the LV could not be distinguished from control (isolength). Potentiation of contraction for the PES's introduced after an isolength pause was dependent on both the heart rate and the extrasystolic interval, whereas the PES's that occurred after a full pause showed no dependence on either of these intervals. PESP elicited during the isolength period was not dependent on either preload and afterload. It is concluded that PESP depends on the combination of heart rate and extrasystolic and postextrasystolic intervals. Further, PESP may be inaccurate in assessing contractile reserve unless the heart rate and extrasystolic interval are known and the PES is introduced after an isolength pause.
Tormo Calandín, C; Manrique Martínez, I
2002-06-01
Children who require cardiopulmonary resuscitation present high mortality and morbidity. The few studies that have been published on this subject use different terminology and methodology in data collection, which makes comparisons, evaluation of efficacy, and the performance of meta-analyses, etc. difficult. Consequently, standardized data collection both in clinical studies on cardiorespiratory arrest and in cardiopulmonary resuscitation in the pediatric age group are required. The Spanish Group of Pediatric Cardiopulmonary Resuscitation emphasizes that recommendations must be simple and easy to understand. The first step in the elaboration of guidelines on data collection is to develop uniform definitions (glossary of terms). The second step comprises the so-called time intervals that include time periods between two events. To describe the intervals of cardiorespiratory arrest different clocks are used: the patient's watch, that of the ambulance, the interval between call and response, etc.Thirdly, a series of clinical results are gathered to determine whether the efforts of cardiopulmonary resuscitation have a positive effect on the patient, the patient's family and society. With the information gathered a registry of data that includes the patient's personal details, general data of the cardiopulmonary resuscitation, treatment, times of performance and definitive patient outcome is made.
14 CFR 25.1443 - Minimum mass flow of supplemental oxygen.
Code of Federal Regulations, 2010 CFR
2010-01-01
...,100 cc. with a constant time interval between respirations. (d) If first-aid oxygen equipment is... minute per person for whom first-aid oxygen is required. (e) If portable oxygen equipment is installed...
Botulinum toxin therapy in Frey's syndrome: a retrospective study of 440 treatments in 100 patients.
Jansen, S; Jerowski, M; Ludwig, L; Fischer-Krall, E; Beutner, D; Grosheva, M
2017-04-01
Frey's syndrome is characterised as sweating, redness and warmth of the parotideal area and is often treated with botulinum toxin A. The objective of this retrospective study was to prove whether the toxin dosage and time-to-treatment intervals change after repeated botulinum toxin injections. The charts of patients, who were treated for Frey's syndrome during the last 16 years, were assessed. Three brands of botulinum toxin A were available for therapy. The Minor test was used to confirm the sweating before each treatment and to determine the toxin dosage. Constant amount of botulinum toxin was injected per cm 2 of the affected area. Patients consulted our department for the next treatment as soon as they felt disturbed by recurring sweating and when the sweating was objectively evident in the Minor test. Time intervals between treatments and injected toxin dosages were assessed. In total, 100 patients received 440 treatments in 16 years. Repeated injections, median 4.0, were carried out in 70.5% of patients. Median time interval to the first injection was 2.8 years. Median time interval between treatments was 12.0 months and showed to be steady (anova, P = .49, F = 1.01). Duration of effect of botulinum toxin on Frey's syndrome was long-lasting and stable with no significantly different time intervals between treatments. The extent of the sweating area did not vary significantly after repeated treatments and required a constant dose of botulinum toxin A. © 2016 John Wiley & Sons Ltd.
40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...
40 CFR 63.11221 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... malfunctions or out-of-control periods, or required monitoring system quality assurance or control activities... collect data according to this section. (b) You must operate the monitoring system and collect data at all required intervals at all times the affected source is operating except for periods of monitoring system...
van Elswijk, Gijs; Schot, Willemijn D; Stegeman, Dick F; Overeem, Sebastiaan
2008-01-01
Background Preparation of the direction of a forthcoming movement has a particularly strong influence on both reaction times and neuronal activity in the primate motor cortex. Here, we aimed to find direct neurophysiologic evidence for the preparation of movement direction in humans. We used single-pulse transcranial magnetic stimulation (TMS) to evoke isolated thumb-movements, of which the direction can be modulated experimentally, for example by training or by motor tasks. Sixteen healthy subjects performed brisk concentric voluntary thumb movements during a reaction time task in which the required movement direction was precued. We assessed whether preparation for the thumb movement lead to changes in the direction of TMS-evoked movements and to changes in amplitudes of motor-evoked potentials (MEPs) from the hand muscles. Results When the required movement direction was precued early in the preparatory interval, reaction times were 50 ms faster than when precued at the end of the preparatory interval. Over time, the direction of the TMS-evoked thumb movements became increasingly variable, but it did not turn towards the precued direction. MEPs from the thumb muscle (agonist) were differentially modulated by the direction of the precue, but only in the late phase of the preparatory interval and thereafter. MEPs from the index finger muscle did not depend on the precued direction and progressively decreased during the preparatory interval. Conclusion Our data show that the human corticospinal movement representation undergoes progressive changes during motor preparation. These changes are accompanied by inhibitory changes in corticospinal excitability, which are muscle specific and depend on the prepared movement direction. This inhibition might indicate a corticospinal braking mechanism that counteracts any preparatory motor activation. PMID:18559096
A parallel algorithm for computing the eigenvalues of a symmetric tridiagonal matrix
NASA Technical Reports Server (NTRS)
Swarztrauber, Paul N.
1993-01-01
A parallel algorithm, called polysection, is presented for computing the eigenvalues of a symmetric tridiagonal matrix. The method is based on a quadratic recurrence in which the characteristic polynomial is constructed on a binary tree from polynomials whose degree doubles at each level. Intervals that contain exactly one zero are determined by the zeros of polynomials at the previous level which ensures that different processors compute different zeros. The signs of the polynomials at the interval endpoints are determined a priori and used to guarantee that all zeros are found. The use of finite-precision arithmetic may result in multiple zeros; however, in this case, the intervals coalesce and their number determines exactly the multiplicity of the zero. For an N x N matrix the eigenvalues can be determined in O(log-squared N) time with N-squared processors and O(N) time with N processors. The method is compared with a parallel variant of bisection that requires O(N-squared) time on a single processor, O(N) time with N processors, and O(log N) time with N-squared processors.
Making a Computer Model of the Most Complex System Ever Built - Continuum
Eastern Interconnection, all as a function of time. All told, that's about 1,000 gigabytes of data the modeling software steps forward in time, those decisions affect how the grid operates under Interconnection at five-minute intervals for one year would have required more than 400 days of computing time
Reading a 400,000-year record of earthquake frequency for an intraplate fault
NASA Astrophysics Data System (ADS)
Williams, Randolph T.; Goodwin, Laurel B.; Sharp, Warren D.; Mozley, Peter S.
2017-05-01
Our understanding of the frequency of large earthquakes at timescales longer than instrumental and historical records is based mostly on paleoseismic studies of fast-moving plate-boundary faults. Similar study of intraplate faults has been limited until now, because intraplate earthquake recurrence intervals are generally long (10s to 100s of thousands of years) relative to conventional paleoseismic records determined by trenching. Long-term variations in the earthquake recurrence intervals of intraplate faults therefore are poorly understood. Longer paleoseismic records for intraplate faults are required both to better quantify their earthquake recurrence intervals and to test competing models of earthquake frequency (e.g., time-dependent, time-independent, and clustered). We present the results of U-Th dating of calcite veins in the Loma Blanca normal fault zone, Rio Grande rift, New Mexico, United States, that constrain earthquake recurrence intervals over much of the past ˜550 ka—the longest direct record of seismic frequency documented for any fault to date. The 13 distinct seismic events delineated by this effort demonstrate that for >400 ka, the Loma Blanca fault produced periodic large earthquakes, consistent with a time-dependent model of earthquake recurrence. However, this time-dependent series was interrupted by a cluster of earthquakes at ˜430 ka. The carbon isotope composition of calcite formed during this seismic cluster records rapid degassing of CO2, suggesting an interval of anomalous fluid source. In concert with U-Th dates recording decreased recurrence intervals, we infer seismicity during this interval records fault-valve behavior. These data provide insight into the long-term seismic behavior of the Loma Blanca fault and, by inference, other intraplate faults.
24 CFR 3280.401 - Structural load tests.
Code of Federal Regulations, 2013 CFR
2013-04-01
... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead... load plus dead load has been reached. Assembly failure shall be considered as design live load...
24 CFR 3280.401 - Structural load tests.
Code of Federal Regulations, 2010 CFR
2010-04-01
... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead... load plus dead load has been reached. Assembly failure shall be considered as design live load...
24 CFR 3280.401 - Structural load tests.
Code of Federal Regulations, 2014 CFR
2014-04-01
... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead... load plus dead load has been reached. Assembly failure shall be considered as design live load...
24 CFR 3280.401 - Structural load tests.
Code of Federal Regulations, 2012 CFR
2012-04-01
... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead... load plus dead load has been reached. Assembly failure shall be considered as design live load...
24 CFR 3280.401 - Structural load tests.
Code of Federal Regulations, 2011 CFR
2011-04-01
... sustaining its dead load plus superimposed live loads equal to 1.75 times the required live loads for a... in 1/4 design live load increments at 10-minute intervals until 1.25 times design live load plus dead... load plus dead load has been reached. Assembly failure shall be considered as design live load...
Pullin, A N; Pairis-Garcia, M D; Campbell, B J; Campler, M R; Proudfoot, K L
2017-11-01
When considering methodologies for collecting behavioral data, continuous sampling provides the most complete and accurate data set whereas instantaneous sampling can provide similar results and also increase the efficiency of data collection. However, instantaneous time intervals require validation to ensure accurate estimation of the data. Therefore, the objective of this study was to validate scan sampling intervals for lambs housed in a feedlot environment. Feeding, lying, standing, drinking, locomotion, and oral manipulation were measured on 18 crossbred lambs housed in an indoor feedlot facility for 14 h (0600-2000 h). Data from continuous sampling were compared with data from instantaneous scan sampling intervals of 5, 10, 15, and 20 min using a linear regression analysis. Three criteria determined if a time interval accurately estimated behaviors: 1) ≥ 0.90, 2) slope not statistically different from 1 ( > 0.05), and 3) intercept not statistically different from 0 ( > 0.05). Estimations for lying behavior were accurate up to 20-min intervals, whereas feeding and standing behaviors were accurate only at 5-min intervals (i.e., met all 3 regression criteria). Drinking, locomotion, and oral manipulation demonstrated poor associations () for all tested intervals. The results from this study suggest that a 5-min instantaneous sampling interval will accurately estimate lying, feeding, and standing behaviors for lambs housed in a feedlot, whereas continuous sampling is recommended for the remaining behaviors. This methodology will contribute toward the efficiency, accuracy, and transparency of future behavioral data collection in lamb behavior research.
A validation of ground ambulance pre-hospital times modeled using geographic information systems.
Patel, Alka B; Waters, Nigel M; Blanchard, Ian E; Doig, Christopher J; Ghali, William A
2012-10-03
Evaluating geographic access to health services often requires determining the patient travel time to a specified service. For urgent care, many research studies have modeled patient pre-hospital time by ground emergency medical services (EMS) using geographic information systems (GIS). The purpose of this study was to determine if the modeling assumptions proposed through prior United States (US) studies are valid in a non-US context, and to use the resulting information to provide revised recommendations for modeling travel time using GIS in the absence of actual EMS trip data. The study sample contained all emergency adult patient trips within the Calgary area for 2006. Each record included four components of pre-hospital time (activation, response, on-scene and transport interval). The actual activation and on-scene intervals were compared with those used in published models. The transport interval was calculated within GIS using the Network Analyst extension of Esri ArcGIS 10.0 and the response interval was derived using previously established methods. These GIS derived transport and response intervals were compared with the actual times using descriptive methods. We used the information acquired through the analysis of the EMS trip data to create an updated model that could be used to estimate travel time in the absence of actual EMS trip records. There were 29,765 complete EMS records for scene locations inside the city and 529 outside. The actual median on-scene intervals were longer than the average previously reported by 7-8 minutes. Actual EMS pre-hospital times across our study area were significantly higher than the estimated times modeled using GIS and the original travel time assumptions. Our updated model, although still underestimating the total pre-hospital time, more accurately represents the true pre-hospital time in our study area. The widespread use of generalized EMS pre-hospital time assumptions based on US data may not be appropriate in a non-US context. The preference for researchers should be to use actual EMS trip records from the proposed research study area. In the absence of EMS trip data researchers should determine which modeling assumptions more accurately reflect the EMS protocols across their study area.
AUTOPLAN: A PC-based automated mission planning tool
NASA Technical Reports Server (NTRS)
Paterra, Frank C.; Allen, Marc S.; Lawrence, George F.
1987-01-01
A PC-based automated mission and resource planning tool, AUTOPLAN, is described, with application to small-scale planning and scheduling systems in the Space Station program. The input is a proposed mission profile, including mission duration, number of allowable slip periods, and requirement profiles for one or more resources as a function of time. A corresponding availability profile is also entered for each resource over the whole time interval under study. AUTOPLAN determines all integrated schedules which do not require more than the available resources.
Lawn mower injuries in children: a 30-year experience.
Nguyen, Anh; Raymond, Simon; Morgan, Vanessa; Peters, Julian; Macgill, Kirstie; Johnstone, Bruce
2008-09-01
Lawn mowers cause severe injuries that are particularly devastating to children. This study analyses the patterns and trends in lawn mower injuries involving children referred to Victoria's principal children's hospital. A retrospective review of the patient medical records at the Royal Children's Hospital (Melbourne) Victoria, Australia was carried out. The series included all patients admitted for lawn mower injury during the 30-year period spanning 1975-2004. Lawn mower injuries treated at Royal Children's Hospital were severe and included partially amputated limbs. Overall, admissions for lawn mower injury generally decreased over time from n = 26 in the 1975-1979 interval to n = 14 in the 2000-2004 interval. However, the frequency of admission for injuries caused by ride-on mowers contradicted the overall trend and generally increased over time from n = 5 in the 1975-1979 interval to n = 11 in the 2000-2004 interval. This is of particular concern. Ride-on lawn mowers caused significantly more severe injuries requiring longer periods of admission and more operations during admission in comparison to standard mowers. Rural location at the time of injury was a risk factor associated with requiring longer periods of admission and more operations during admission. Children injured while operating mowers were generally older than children injured as bystanders. Lawn mower injuries are a significant cause of morbidity. These injuries are particularly devastating to children. The tragedy is keenly felt in the realization that these devastating injuries to children could all be prevented. Strategic preventative measures should be developed through partnership between the medical profession, the media, industry specialists and the wider community.
NASA Technical Reports Server (NTRS)
Elrod, B. D.; Jacobsen, A.; Cook, R. A.; Singh, R. N. P.
1983-01-01
One-way range and Doppler methods for providing user orbit and time determination are examined. Forward link beacon tracking, with on-board processing of independent navigation signals broadcast continuously by TDAS spacecraft; forward link scheduled tracking; with on-board processing of navigation data received during scheduled TDAS forward link service intervals; and return link scheduled tracking; with ground-based processing of user generated navigation data during scheduled TDAS return link service intervals are discussed. A system level definition and requirements assessment for each alternative, an evaluation of potential navigation performance and comparison with TDAS mission model requirements is included. TDAS satellite tracking is also addressed for two alternatives: BRTS and VLBI tracking.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cannon, Bradford E.; Smith, Charles W.; Isenberg, Philip A.
In two earlier publications we analyzed 502 intervals of magnetic waves excited by newborn interstellar pickup protons that were observed by the Ulysses spacecraft. Due to the considerable effort required in identifying these events, we provide a list of the times for the 502 wave event intervals previously identified. In the process, we provide a brief description of how the waves were found and what their properties are. We also remind the reader of the conditions that permit the waves to reach observable levels and explain why the waves are not seen more often.
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms.
Jafari Tadi, Mojtaba; Lehtonen, Eero; Hurnanen, Tero; Koskinen, Juho; Eriksson, Jonas; Pänkäälä, Mikko; Teräs, Mika; Koivisto, Tero
2016-11-01
Heart rate monitoring helps in assessing the functionality and condition of the cardiovascular system. We present a new real-time applicable approach for estimating beat-to-beat time intervals and heart rate in seismocardiograms acquired from a tri-axial microelectromechanical accelerometer. Seismocardiography (SCG) is a non-invasive method for heart monitoring which measures the mechanical activity of the heart. Measuring true beat-to-beat time intervals from SCG could be used for monitoring of the heart rhythm, for heart rate variability analysis and for many other clinical applications. In this paper we present the Hilbert adaptive beat identification technique for the detection of heartbeat timings and inter-beat time intervals in SCG from healthy volunteers in three different positions, i.e. supine, left and right recumbent. Our method is electrocardiogram (ECG) independent, as it does not require any ECG fiducial points to estimate the beat-to-beat intervals. The performance of the algorithm was tested against standard ECG measurements. The average true positive rate, positive prediction value and detection error rate for the different positions were, respectively, supine (95.8%, 96.0% and ≃0.6%), left (99.3%, 98.8% and ≃0.001%) and right (99.53%, 99.3% and ≃0.01%). High correlation and agreement was observed between SCG and ECG inter-beat intervals (r > 0.99) for all positions, which highlights the capability of the algorithm for SCG heart monitoring from different positions. Additionally, we demonstrate the applicability of the proposed method in smartphone based SCG. In conclusion, the proposed algorithm can be used for real-time continuous unobtrusive cardiac monitoring, smartphone cardiography, and in wearable devices aimed at health and well-being applications.
Estimation of sojourn time in chronic disease screening without data on interval cases.
Chen, T H; Kuo, H S; Yen, M F; Lai, M S; Tabar, L; Duffy, S W
2000-03-01
Estimation of the sojourn time on the preclinical detectable period in disease screening or transition rates for the natural history of chronic disease usually rely on interval cases (diagnosed between screens). However, to ascertain such cases might be difficult in developing countries due to incomplete registration systems and difficulties in follow-up. To overcome this problem, we propose three Markov models to estimate parameters without using interval cases. A three-state Markov model, a five-state Markov model related to regional lymph node spread, and a five-state Markov model pertaining to tumor size are applied to data on breast cancer screening in female relatives of breast cancer cases in Taiwan. Results based on a three-state Markov model give mean sojourn time (MST) 1.90 (95% CI: 1.18-4.86) years for this high-risk group. Validation of these models on the basis of data on breast cancer screening in the age groups 50-59 and 60-69 years from the Swedish Two-County Trial shows the estimates from a three-state Markov model that does not use interval cases are very close to those from previous Markov models taking interval cancers into account. For the five-state Markov model, a reparameterized procedure using auxiliary information on clinically detected cancers is performed to estimate relevant parameters. A good fit of internal and external validation demonstrates the feasibility of using these models to estimate parameters that have previously required interval cancers. This method can be applied to other screening data in which there are no data on interval cases.
Effects of an Approach Spacing Flight Deck Tool on Pilot Eyescan
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Nadler, Eric D.
2004-01-01
An airborne tool has been developed based on the concept of an aircraft maintaining a time-based spacing interval from the preceding aircraft. The Advanced Terminal Area Approach Spacing (ATAAS) tool uses Automatic Dependent Surveillance-Broadcast (ADS-B) aircraft state data to compute a speed command for the ATAAS-equipped aircraft to obtain a required time interval behind another aircraft. The tool and candidate operational procedures were tested in a high-fidelity, full mission simulator with active airline subject pilots flying an arrival scenario using three different modes for speed control. Eyetracker data showed only slight changes in instrument scan patterns, and no significant change in the amount of time spent looking out the window with ATAAS, versus standard ILS procedures.
Temporal Integration of Auditory Information Is Invariant to Temporal Grouping Cues1,2,3
Tsunada, Joji
2015-01-01
Abstract Auditory perception depends on the temporal structure of incoming acoustic stimuli. Here, we examined whether a temporal manipulation that affects the perceptual grouping also affects the time dependence of decisions regarding those stimuli. We designed a novel discrimination task that required human listeners to decide whether a sequence of tone bursts was increasing or decreasing in frequency. We manipulated temporal perceptual-grouping cues by changing the time interval between the tone bursts, which led to listeners hearing the sequences as a single sound for short intervals or discrete sounds for longer intervals. Despite these strong perceptual differences, this manipulation did not affect the efficiency of how auditory information was integrated over time to form a decision. Instead, the grouping manipulation affected subjects’ speed−accuracy trade-offs. These results indicate that the temporal dynamics of evidence accumulation for auditory perceptual decisions can be invariant to manipulations that affect the perceptual grouping of the evidence. PMID:26464975
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-16
... (ATA), on behalf of its member Delta Air Lines Inc. (Delta), asked that the 60-month compliance time in the supplemental NPRM be extended to better align with industry standard tank entry intervals. Delta stated that the required modifications will require entry into the main and center fuel tanks, and Delta...
Characteristics of clinical trials that require participants to be fluent in English.
Egleston, Brian L; Pedraza, Omar; Wong, Yu-Ning; Dunbrack, Roland L; Griffin, Candace L; Ross, Eric A; Beck, J Robert
2015-12-01
Diverse samples in clinical trials can make findings more generalizable. We sought to characterize the prevalence of clinical trials in the United States that required English fluency for participants to enroll in the trial. We randomly chose over 10,000 clinical trial protocols registered with ClinicalTrials.gov and examined the inclusion and exclusion criteria of the trials. We compared the relationship of clinical trial characteristics with English fluency inclusion requirements. We merged the ClinicalTrials.gov data with US Census and American Community Survey data to investigate the association of English-language restrictions with ZIP-code-level demographic characteristics of participating institutions. We used Chi-squared tests, t-tests, and logistic regression models for analyses. English fluency requirements have been increasing over time, from 1.7% of trials having such requirements before 2000 to 9.0% after 2010 (p < 0.001 from Chi-squared test). Industry-sponsored trials had low rates of English fluency requirements (1.8%), while behavioral trials had high rates (28.4%). Trials opening in the Northeast of the United States had the highest regional English requirement rates (10.7%), while trials opening in more than one region had the lowest (3.3%, p<0.001). Since 1995, trials opening in ZIP codes with larger Hispanic populations were less likely to have English fluency requirements (odds ratio=0.92 for each 10% increase in proportion of Hispanics, 95% confidence interval=0.86-0.98, p=0.013). Trials opening in ZIP codes with more residents self-identifying as Black/African American (odds ratio=1.87, 95% confidence interval=1.36-2.58, p<0.001 for restricted cubic spline term) or Asian (odds ratio=1.16 for linear term, 95% confidence interval=1.07-1.25, p<0.001) were more likely to have English fluency requirements. ZIP codes with higher poverty rates had trials with more English-language restrictions (odds ratio=1.06 for a 10% poverty rate increase, 95% confidence interval=1.001-1.11, p=0.045). There was a statistically significant interaction between year and intervention type, such that the increase in English fluency requirements was more common for some interventions than for others. The proportion of clinical trials registered with ClinicalTrials.gov that have English fluency requirements for study inclusion has been increasing over time. English-language restrictions are associated with a number of characteristics, including the demographic characteristics of communities in which the sponsoring institutions are located. © The Author(s) 2015.
ERIC Educational Resources Information Center
Adolph, Karen E.; Robinson, Scott R.
2011-01-01
Research in developmental psychology requires sampling at different time points. Accurate depictions of developmental change provide a foundation for further empirical studies and theories about developmental mechanisms. However, overreliance on widely spaced sampling intervals in cross-sectional and longitudinal designs threatens the validity of…
Revising the "Rule of Three" for inferring seizure freedom.
Westover, M Brandon; Cormier, Justine; Bianchi, Matt T; Shafi, Mouhsin; Kilbride, Ronan; Cole, Andrew J; Cash, Sydney S
2012-02-01
How long after starting a new medication must a patient go without seizures before they can be regarded as seizure-free? A recent International League Against Epilepsy (ILAE) task force proposed using a "Rule of Three" as an operational definition of seizure freedom, according to which a patient should be considered seizure-free following an intervention after a period without seizures has elapsed equal to three times the longest preintervention interseizure interval over the previous year. This rule was motivated in large part by statistical considerations advanced in a classic 1983 paper by Hanley and Lippman-Hand. However, strict adherence to the statistical logic of this rule generally requires waiting much longer than recommended by the ILAE task force. Therefore, we set out to determine whether an alternative approach to the Rule of Three might be possible, and under what conditions the rule may be expected to hold or would need to be extended. Probabilistic modeling and application of Bayes' rule. We find that an alternative approach to the problem of inferring seizure freedom supports using the Rule of Three in the way proposed by the ILAE in many cases, particularly in evaluating responses to a first trial of antiseizure medication, and to favorably-selected epilepsy surgical candidates. In cases where the a priori odds of success are less favorable, our analysis requires longer seizure-free observation periods before declaring seizure freedom, up to six times the average preintervention interseizure interval. The key to our approach is to take into account not only the time elapsed without seizures but also empirical data regarding the a priori probability of achieving seizure freedom conferred by a particular intervention. In many cases it may be reasonable to consider a patient seizure-free after they have gone without seizures for a period equal to three times the preintervention interseizure interval, as proposed on pragmatic grounds in a recent ILAE position paper, although in other commonly encountered cases a waiting time up to six times this interval is required. In this work we have provided a coherent theoretical basis for modified criterion for seizure freedom, which we call the "Rule of Three-To-Six." Wiley Periodicals, Inc. © 2011 International League Against Epilepsy.
Revising the Rule Of Three For Inferring Seizure Freedom
Westover, M. Brandon; Cormier, Justine; Bianchi, Matt T.; Shafi, Mouhsin; Kilbride, Ronan; Cole, Andrew J.; Cash, Sydney S.
2011-01-01
Summary Purpose How long after starting a new medication must a patient go without seizures before they can be regarded as seizure free? A recent ILAE task force proposed using a “Rule of Three” as an operational definition of seizure freedom, according to which a patient should be considered seizure-free following an intervention after a period without seizures has elapsed equal to three times the longest pre-intervention inter-seizure interval over the previous year. This rule was motivated in large part by statistical considerations advanced in a classic 1983 paper by Hanley and Lippman-Hand. However, strict adherence to the statistical logic of this rule generally requires waiting much longer than recommended by the ILAE task force. Therefore, we set out to determine whether an alternative approach to the Rule of Three might be possible, and under what conditions the rule may be expected to hold or would need to be extended. Methods Probabilistic modeling and application of Bayes’ rule. Key Findings We find that an alternative approach to the problem of inferring seizure freedom supports using the Rule of Three in the way proposed by the ILAE in many cases, particularly in evaluating responses to a first trial of anti-seizure medication, and to favorably-selected epilepsy surgical candidates. In cases where the a priori odds of success are less favorable, our analysis requires longer seizure-free observation periods before declaring seizure freedom, up to six times the average pre-intervention insterseizure interval. The key to our approach is to take into account not only the time elapsed without seizures but also empirical data regarding the a priori probability of achieving seizure freedom conferred by a particular intervention. Significance In many cases it may be reasonable to consider a patient seizure free after they have gone without seizures for a period equal to three times the pre-intervention inter-seizure interval, as proposed on pragmatic grounds in a recent ILAE position paper, though in other commonly encountered cases a waiting time up to six times this interval is required. In this work we have provided a coherent theoretical basis for modified criterion for seizure freedom, which we call the “Rule of Three-To-Six”. PMID:22191711
Yang, Qian; Lew, Hwee Yeong; Peh, Raymond Hock Huat; Metz, Michael Patrick; Loh, Tze Ping
2016-10-01
Reference intervals are the most commonly used decision support tool when interpreting quantitative laboratory results. They may require partitioning to better describe subpopulations that display significantly different reference values. Partitioning by age is particularly important for the paediatric population since there are marked physiological changes associated with growth and maturation. However, most partitioning methods are either technically complex or require prior knowledge of the underlying physiology/biological variation of the population. There is growing interest in the use of continuous centile curves, which provides seamless laboratory reference values as a child grows, as an alternative to rigidly described fixed reference intervals. However, the mathematical functions that describe these curves can be complex and may not be easily implemented in laboratory information systems. Hence, the use of fixed reference intervals is expected to continue for a foreseeable time. We developed a method that objectively proposes optimised age partitions and reference intervals for quantitative laboratory data (http://research.sph.nus.edu.sg/pp/ppResult.aspx), based on the sum of gradient that best describes the underlying distribution of the continuous centile curves. It is hoped that this method may improve the selection of age intervals for partitioning, which is receiving increasing attention in paediatric laboratory medicine. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Physical Layer Ethernet Clock Synchronization
2010-11-01
42 nd Annual Precise Time and Time Interval (PTTI) Meeting 77 PHYSICAL LAYER ETHERNET CLOCK SYNCHRONIZATION Reinhard Exel, Georg...oeaw.ac.at Nikolaus Kerö Oregano Systems, Mohsgasse 1, 1030 Wien, Austria E-mail: nikolaus.keroe@oregano.at Abstract Clock synchronization ...is a service widely used in distributed networks to coordinate data acquisition and actions. As the requirement to achieve tighter synchronization
Performance Analysis of the IEEE 802.11p Multichannel MAC Protocol in Vehicular Ad Hoc Networks
2017-01-01
Vehicular Ad Hoc Networks (VANETs) employ multichannel to provide a variety of safety and non-safety applications, based on the IEEE 802.11p and IEEE 1609.4 protocols. The safety applications require timely and reliable transmissions, while the non-safety applications require efficient and high throughput. In the IEEE 1609.4 protocol, operating interval is divided into alternating Control Channel (CCH) interval and Service Channel (SCH) interval with an identical length. During the CCH interval, nodes transmit safety-related messages and control messages, and Enhanced Distributed Channel Access (EDCA) mechanism is employed to allow four Access Categories (ACs) within a station with different priorities according to their criticality for the vehicle’s safety. During the SCH interval, the non-safety massages are transmitted. An analytical model is proposed in this paper to evaluate performance, reliability and efficiency of the IEEE 802.11p and IEEE 1609.4 protocols. The proposed model improves the existing work by taking serval aspects and the character of multichannel switching into design consideration. Extensive performance evaluations based on analysis and simulation help to validate the accuracy of the proposed model and analyze the capabilities and limitations of the IEEE 802.11p and IEEE 1609.4 protocols, and enhancement suggestions are given. PMID:29231882
Performance Analysis of the IEEE 802.11p Multichannel MAC Protocol in Vehicular Ad Hoc Networks.
Song, Caixia
2017-12-12
Vehicular Ad Hoc Networks (VANETs) employ multichannel to provide a variety of safety and non-safety applications, based on the IEEE 802.11p and IEEE 1609.4 protocols. The safety applications require timely and reliable transmissions, while the non-safety applications require efficient and high throughput. In the IEEE 1609.4 protocol, operating interval is divided into alternating Control Channel (CCH) interval and Service Channel (SCH) interval with an identical length. During the CCH interval, nodes transmit safety-related messages and control messages, and Enhanced Distributed Channel Access (EDCA) mechanism is employed to allow four Access Categories (ACs) within a station with different priorities according to their criticality for the vehicle's safety. During the SCH interval, the non-safety massages are transmitted. An analytical model is proposed in this paper to evaluate performance, reliability and efficiency of the IEEE 802.11p and IEEE 1609.4 protocols. The proposed model improves the existing work by taking serval aspects and the character of multichannel switching into design consideration. Extensive performance evaluations based on analysis and simulation help to validate the accuracy of the proposed model and analyze the capabilities and limitations of the IEEE 802.11p and IEEE 1609.4 protocols, and enhancement suggestions are given.
Evaluation of a Tool for Airborne-Managed In-Trail Approach Spacing
DOT National Transportation Integrated Search
2005-08-01
The Advanced Terminal Area Approach Spacing (ATAAS) tool uses Automatic Dependent Surveillance-Broadcast aircraft state data to compute a speed command for an ATAAS-equipped aircraft to follow and obtain a required time interval behind another aircra...
Trading Speed and Accuracy by Coding Time: A Coupled-circuit Cortical Model
Standage, Dominic; You, Hongzhi; Wang, Da-Hui; Dorris, Michael C.
2013-01-01
Our actions take place in space and time, but despite the role of time in decision theory and the growing acknowledgement that the encoding of time is crucial to behaviour, few studies have considered the interactions between neural codes for objects in space and for elapsed time during perceptual decisions. The speed-accuracy trade-off (SAT) provides a window into spatiotemporal interactions. Our hypothesis is that temporal coding determines the rate at which spatial evidence is integrated, controlling the SAT by gain modulation. Here, we propose that local cortical circuits are inherently suited to the relevant spatial and temporal coding. In simulations of an interval estimation task, we use a generic local-circuit model to encode time by ‘climbing’ activity, seen in cortex during tasks with a timing requirement. The model is a network of simulated pyramidal cells and inhibitory interneurons, connected by conductance synapses. A simple learning rule enables the network to quickly produce new interval estimates, which show signature characteristics of estimates by experimental subjects. Analysis of network dynamics formally characterizes this generic, local-circuit timing mechanism. In simulations of a perceptual decision task, we couple two such networks. Network function is determined only by spatial selectivity and NMDA receptor conductance strength; all other parameters are identical. To trade speed and accuracy, the timing network simply learns longer or shorter intervals, driving the rate of downstream decision processing by spatially non-selective input, an established form of gain modulation. Like the timing network's interval estimates, decision times show signature characteristics of those by experimental subjects. Overall, we propose, demonstrate and analyse a generic mechanism for timing, a generic mechanism for modulation of decision processing by temporal codes, and we make predictions for experimental verification. PMID:23592967
Using operations research to plan improvement of the transport of critically ill patients.
Chen, Jing; Awasthi, Anjali; Shechter, Steven; Atkins, Derek; Lemke, Linda; Fisher, Les; Dodek, Peter
2013-01-01
Operations research is the application of mathematical modeling, statistical analysis, and mathematical optimization to understand and improve processes in organizations. The objective of this study was to illustrate how the methods of operations research can be used to identify opportunities to reduce the absolute value and variability of interfacility transport intervals for critically ill patients. After linking data from two patient transport organizations in British Columbia, Canada, for all critical care transports during the calendar year 2006, the steps for transfer of critically ill patients were tabulated into a series of time intervals. Statistical modeling, root-cause analysis, Monte Carlo simulation, and sensitivity analysis were used to test the effect of changes in component intervals on overall duration and variation of transport times. Based on quality improvement principles, we focused on reducing the 75th percentile and standard deviation of these intervals. We analyzed a total of 3808 ground and air transports. Constraining time spent by transport personnel at sending and receiving hospitals was projected to reduce the total time taken by 33 minutes with as much as a 20% reduction in standard deviation of these transport intervals in 75% of ground transfers. Enforcing a policy of requiring acceptance of patients who have life- or limb-threatening conditions or organ failure was projected to reduce the standard deviation of air transport time by 63 minutes and the standard deviation of ground transport time by 68 minutes. Based on findings from our analyses, we developed recommendations for technology renovation, personnel training, system improvement, and policy enforcement. Use of the tools of operations research identifies opportunities for improvement in a complex system of critical care transport.
Near-Earth-Object identification over apparitions using n-body ranging
NASA Astrophysics Data System (ADS)
Granvik, Mikael; Muinonen, Karri
2007-05-01
Earth-based telescopes can observe Near-Earth objects (NEOs) continuously for a few weeks or months during each apparition. Due to the usually complicated dynamics of the Sun-Earth-NEO triplet, the time interval between consecutive apparitions typically ranges from months to several years. On these timescales single-apparition sets of observations (SASs) having reasonably small observational time-intervals lead to substantial orbital uncertainties. The linking of SASs over apparitions thus becomes a nontrivial task. Of a total of roughly 4,100 NEO observation sets, or orbits, currently known, some 500 are SASs for which the observational time interval is less than 7 days. Either these SASs have not been observed at an apparition following the discovery apparition (some 40% of the above NEO SASs have been obtained in 2005 or later), or the linkage of SASs has failed, an option which should preferably be eliminated. As a continuation to our work on the short-arc linking problem at the discovery moment (Granvik and Muinonen, 2005, Icarus 179, p. 109), we have investigated the possibility of using a similar method for the linking of SASs over apparitions. Assuming that the observational time-interval for SASs of NEOs is typically at least one day (minimum requirement set by the Minor Planet Center), the orbital-element probability density function is constrained as compared to the typical short-arc case with an observational time interval of only a few tens of minutes. Because of the smaller orbital-element uncertainty, we can use the short-arc method (comparison in ephemeris space) for longer time spans, or even do the comparison directly in orbital-element space (Keplerian, equinoctial, etc.), thus allowing us to assess the problem of linking SASs of NEOs. We will present linking results by using both simulated and real NEO SASs.
Joint Command Decision Support 21st Century Technology Demonstration: Human Factors Style Guide
2009-03-01
education, religion , etc.) or for a variable sampled at discrete intervals. Histograms (bar charts without spaces between the bars) shall be used when...with Zulu time as the default. The seconds are optional. All colons are required and the Zulu (Z) shall be capitalized. 3. The display shall...include Zulu time and local time; Zulu time shall be presented above local time. 4. The date time group shall be presented on the COMDAT status bar on the
Fast temporal neural learning using teacher forcing
NASA Technical Reports Server (NTRS)
Toomarian, Nikzad (Inventor); Bahren, Jacob (Inventor)
1992-01-01
A neural network is trained to output a time dependent target vector defined over a predetermined time interval in response to a time dependent input vector defined over the same time interval by applying corresponding elements of the error vector, or difference between the target vector and the actual neuron output vector, to the inputs of corresponding output neurons of the network as corrective feedback. This feedback decreases the error and quickens the learning process, so that a much smaller number of training cycles are required to complete the learning process. A conventional gradient descent algorithm is employed to update the neural network parameters at the end of the predetermined time interval. The foregoing process is repeated in repetitive cycles until the actual output vector corresponds to the target vector. In the preferred embodiment, as the overall error of the neural network output decreasing during successive training cycles, the portion of the error fed back to the output neurons is decreased accordingly, allowing the network to learn with greater freedom from teacher forcing as the network parameters converge to their optimum values. The invention may also be used to train a neural network with stationary training and target vectors.
Fast temporal neural learning using teacher forcing
NASA Technical Reports Server (NTRS)
Toomarian, Nikzad (Inventor); Bahren, Jacob (Inventor)
1995-01-01
A neural network is trained to output a time dependent target vector defined over a predetermined time interval in response to a time dependent input vector defined over the same time interval by applying corresponding elements of the error vector, or difference between the target vector and the actual neuron output vector, to the inputs of corresponding output neurons of the network as corrective feedback. This feedback decreases the error and quickens the learning process, so that a much smaller number of training cycles are required to complete the learning process. A conventional gradient descent algorithm is employed to update the neural network parameters at the end of the predetermined time interval. The foregoing process is repeated in repetitive cycles until the actual output vector corresponds to the target vector. In the preferred embodiment, as the overall error of the neural network output decreasing during successive training cycles, the portion of the error fed back to the output neurons is decreased accordingly, allowing the network to learn with greater freedom from teacher forcing as the network parameters converge to their optimum values. The invention may also be used to train a neural network with stationary training and target vectors.
Time frequency requirements for radio interferometric earth physics
NASA Technical Reports Server (NTRS)
Thomas, J. B.; Fliegel, H. F.
1973-01-01
Two systems of VLBI (Very Long Baseline Interferometry) are now applicable to earth physics: an intercontinental baseline system using antennas of the NASA Deep Space Network, now observing at one-month intervals to determine UTI for spacecraft navigation; and a shorter baseline system called ARIES (Astronomical Radio Interferometric Earth Surveying), to be used to measure crustal movement in California for earthquake hazards estimation. On the basis of experience with the existing DSN system, a careful study has been made to estimate the time and frequency requirements of both the improved intercontinental system and of ARIES. Requirements for the two systems are compared and contrasted.
Bhattacharjee, Arindam; Ye, Amanda J; Lisak, Joy A; Vargas, Maria G; Goldreich, Daniel
2010-10-27
Braille reading is a demanding task that requires the identification of rapidly varying tactile patterns. During proficient reading, neighboring characters impact the fingertip at ∼100 ms intervals, and adjacent raised dots within a character at 50 ms intervals. Because the brain requires time to interpret afferent sensorineural activity, among other reasons, tactile stimuli separated by such short temporal intervals pose a challenge to perception. How, then, do proficient Braille readers successfully interpret inputs arising from their fingertips at such rapid rates? We hypothesized that somatosensory perceptual consolidation occurs more rapidly in proficient Braille readers. If so, Braille readers should outperform sighted participants on masking tasks, which demand rapid perceptual processing, but would not necessarily outperform the sighted on tests of simple vibrotactile sensitivity. To investigate, we conducted two-interval forced-choice vibrotactile detection, amplitude discrimination, and masking tasks on the index fingertips of 89 sighted and 57 profoundly blind humans. Sighted and blind participants had similar unmasked detection (25 ms target tap) and amplitude discrimination (compared with 100 μm reference tap) thresholds, but congenitally blind Braille readers, the fastest readers among the blind participants, exhibited significantly less masking than the sighted (masker, 50 Hz, 50 μm; target-masker delays, ±50 and ±100 ms). Indeed, Braille reading speed correlated significantly and specifically with masking task performance, and in particular with the backward masking decay time constant. We conclude that vibrotactile sensitivity is unchanged but that perceptual processing is accelerated in congenitally blind Braille readers.
Bhattacharjee, Arindam; Ye, Amanda J.; Lisak, Joy A.; Vargas, Maria G.; Goldreich, Daniel
2010-01-01
Braille reading is a demanding task that requires the identification of rapidly varying tactile patterns. During proficient reading, neighboring characters impact the fingertip at about 100-ms intervals, and adjacent raised dots within a character at 50-ms intervals. Because the brain requires time to interpret afferent sensorineural activity, among other reasons, tactile stimuli separated by such short temporal intervals pose a challenge to perception. How, then, do proficient Braille readers successfully interpret inputs arising from their fingertips at such rapid rates? We hypothesized that somatosensory perceptual consolidation occurs more rapidly in proficient Braille readers. If so, Braille readers should outperform sighted participants on masking tasks, which demand rapid perceptual processing, but would not necessarily outperform the sighted on tests of simple vibrotactile sensitivity. To investigate, we conducted two-interval forced-choice vibrotactile detection, amplitude discrimination, and masking tasks on the index fingertips of 89 sighted and 57 profoundly blind humans. Sighted and blind participants had similar unmasked detection (25-ms target tap) and amplitude discrimination (compared to 100-micron reference tap) thresholds, but congenitally blind Braille readers, the fastest readers among the blind participants, exhibited significantly less masking than the sighted (masker: 50-Hz, 50-micron; target-masker delays ±50 and ±100 ms). Indeed, Braille reading speed correlated significantly and specifically with masking task performance, and in particular with the backward masking decay time constant. We conclude that vibrotactile sensitivity is unchanged, but that perceptual processing is accelerated in congenitally blind Braille readers. PMID:20980584
Comparing bandwidth requirements for digital baseband signals.
NASA Technical Reports Server (NTRS)
Houts, R. C.; Green, T. A.
1972-01-01
This paper describes the relative bandwidth requirements of the common digital baseband signaling techniques used for data transmission. Bandwidth considerations include the percentage of total power in a properly encoded PN sequence passed at bandwidths of 0.5, 1, 2 and 3 times the reciprocal of the bit interval. The signals considered in this study are limited to the binary class. The study compares such signaling techniques as delay modulation, bipolar, biternary, duobinary, pair selected ternary and time polarity control in addition to the conventional NRZ, RZ and BI-phi schemes.
14 CFR 29.809 - Emergency exit arrangement.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... self-supporting slide or equivalent, and must be designed to meet the following requirements: (1) It must be automatically deployed, and deployment must begin during the interval between the time the exit...
14 CFR 29.809 - Emergency exit arrangement.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... self-supporting slide or equivalent, and must be designed to meet the following requirements: (1) It must be automatically deployed, and deployment must begin during the interval between the time the exit...
14 CFR 29.809 - Emergency exit arrangement.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... self-supporting slide or equivalent, and must be designed to meet the following requirements: (1) It must be automatically deployed, and deployment must begin during the interval between the time the exit...
14 CFR 29.809 - Emergency exit arrangement.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... self-supporting slide or equivalent, and must be designed to meet the following requirements: (1) It must be automatically deployed, and deployment must begin during the interval between the time the exit...
14 CFR 29.809 - Emergency exit arrangement.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Personnel and Cargo... self-supporting slide or equivalent, and must be designed to meet the following requirements: (1) It must be automatically deployed, and deployment must begin during the interval between the time the exit...
Severity of Vision Loss Interacts With Word-Specific Features to Impact Out-Loud Reading in Glaucoma
Mathews, Priya M.; Rubin, Gary S.; McCloskey, Michael; Salek, Sherveen; Ramulu, Pradeep Y.
2015-01-01
Purpose. To assess the impact of glaucoma-related vision loss on measures of out-loud reading, including time to say individual words, interval time between consecutive words, lexical errors, skipped words, and repetitions. Methods. Glaucoma subjects (n = 63) with bilateral visual field loss and glaucoma suspect controls (n = 57) were recorded while reading a standardized passage out loud. A masked evaluator determined the start and end of each recorded word and identified reading errors. Results. Glaucoma subjects demonstrated longer durations to recite individual words (265 vs. 243 ms, P < 0.001), longer intervals between words (154 vs. 124 ms, P < 0.001), and longer word/post-word interval complexes (the time spanned by the word and the interval following the word; 419 vs. 367 ms, P < 0.001) than controls. In multivariable analyses, each 0.1 decrement in log contrast sensitivity (logCS) was associated with a 15.0 ms longer word/post-interval complex (95% confidence interval [CI] = 9.6–20.4; P < 0.001). Contrast sensitivity was found to significantly interact with word length, word frequency, and word location at the end of a line with regards to word/post-word interval complex duration (P < 0.05 for all). Glaucoma severity was also associated with more lexical errors (Odds ratio = 1.20 for every 0.1 logCS decrement; 95% CI = 1.02–1.39, P < 0.05), but not with more skipped or repeated words. Conclusions. Glaucoma patients with greater vision loss make more lexical errors, are slower in reciting longer and less frequently used words, and more slowly transition to new lines of text. These problem areas may require special attention when designing methods to rehabilitate reading in patients with glaucoma. PMID:25737150
A validation of ground ambulance pre-hospital times modeled using geographic information systems
2012-01-01
Background Evaluating geographic access to health services often requires determining the patient travel time to a specified service. For urgent care, many research studies have modeled patient pre-hospital time by ground emergency medical services (EMS) using geographic information systems (GIS). The purpose of this study was to determine if the modeling assumptions proposed through prior United States (US) studies are valid in a non-US context, and to use the resulting information to provide revised recommendations for modeling travel time using GIS in the absence of actual EMS trip data. Methods The study sample contained all emergency adult patient trips within the Calgary area for 2006. Each record included four components of pre-hospital time (activation, response, on-scene and transport interval). The actual activation and on-scene intervals were compared with those used in published models. The transport interval was calculated within GIS using the Network Analyst extension of Esri ArcGIS 10.0 and the response interval was derived using previously established methods. These GIS derived transport and response intervals were compared with the actual times using descriptive methods. We used the information acquired through the analysis of the EMS trip data to create an updated model that could be used to estimate travel time in the absence of actual EMS trip records. Results There were 29,765 complete EMS records for scene locations inside the city and 529 outside. The actual median on-scene intervals were longer than the average previously reported by 7–8 minutes. Actual EMS pre-hospital times across our study area were significantly higher than the estimated times modeled using GIS and the original travel time assumptions. Our updated model, although still underestimating the total pre-hospital time, more accurately represents the true pre-hospital time in our study area. Conclusions The widespread use of generalized EMS pre-hospital time assumptions based on US data may not be appropriate in a non-US context. The preference for researchers should be to use actual EMS trip records from the proposed research study area. In the absence of EMS trip data researchers should determine which modeling assumptions more accurately reflect the EMS protocols across their study area. PMID:23033894
Optimal Measurement Interval for Emergency Department Crowding Estimation Tools.
Wang, Hao; Ojha, Rohit P; Robinson, Richard D; Jackson, Bradford E; Shaikh, Sajid A; Cowden, Chad D; Shyamanand, Rath; Leuck, JoAnna; Schrader, Chet D; Zenarosa, Nestor R
2017-11-01
Emergency department (ED) crowding is a barrier to timely care. Several crowding estimation tools have been developed to facilitate early identification of and intervention for crowding. Nevertheless, the ideal frequency is unclear for measuring ED crowding by using these tools. Short intervals may be resource intensive, whereas long ones may not be suitable for early identification. Therefore, we aim to assess whether outcomes vary by measurement interval for 4 crowding estimation tools. Our eligible population included all patients between July 1, 2015, and June 30, 2016, who were admitted to the JPS Health Network ED, which serves an urban population. We generated 1-, 2-, 3-, and 4-hour ED crowding scores for each patient, using 4 crowding estimation tools (National Emergency Department Overcrowding Scale [NEDOCS], Severely Overcrowded, Overcrowded, and Not Overcrowded Estimation Tool [SONET], Emergency Department Work Index [EDWIN], and ED Occupancy Rate). Our outcomes of interest included ED length of stay (minutes) and left without being seen or eloped within 4 hours. We used accelerated failure time models to estimate interval-specific time ratios and corresponding 95% confidence limits for length of stay, in which the 1-hour interval was the reference. In addition, we used binomial regression with a log link to estimate risk ratios (RRs) and corresponding confidence limit for left without being seen. Our study population comprised 117,442 patients. The time ratios for length of stay were similar across intervals for each crowding estimation tool (time ratio=1.37 to 1.30 for NEDOCS, 1.44 to 1.37 for SONET, 1.32 to 1.27 for EDWIN, and 1.28 to 1.23 for ED Occupancy Rate). The RRs of left without being seen differences were also similar across intervals for each tool (RR=2.92 to 2.56 for NEDOCS, 3.61 to 3.36 for SONET, 2.65 to 2.40 for EDWIN, and 2.44 to 2.14 for ED Occupancy Rate). Our findings suggest limited variation in length of stay or left without being seen between intervals (1 to 4 hours) regardless of which of the 4 crowding estimation tools were used. Consequently, 4 hours may be a reasonable interval for assessing crowding with these tools, which could substantially reduce the burden on ED personnel by requiring less frequent assessment of crowding. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Shuttle program: OFT ascent/descent ancillary data requirements document
NASA Technical Reports Server (NTRS)
Bond, A. C., Jr.; Knoedler, J.
1980-01-01
Requirements are presented for the ascent/descent (A/D) navigation and attitude-dependent ancillary data products to be generated for the space shuttle orbiter in support of the orbital flight test (OFT) flight test requirements, MPAD guidance and navigation performance assessment, and the mission evaluation team. The A/D ancillary data support for OFT mission evaluation activities is confined to providing postflight position, velocity, attitude, and associated navigation and attitude derived parameters for the Orbiter over particular flight phases and time intervals.
Richards, Kyle A; Ham, Sandra; Cohn, Joshua A; Steinberg, Gary D
2016-01-01
To determine the time to bladder cancer diagnosis from initial infection-like symptoms and its impact on cancer outcomes. Using Surveillance, Epidemiology and End Results-Medicare, we designed a retrospective cohort study identifying beneficiaries aged ≥ 66 years diagnosed with bladder cancer from 2007 to 2009. Patients were required to have a hematuria or urinary tract infection claim within 1 year of bladder cancer diagnosis (n = 21 216), and have 2 years of prior Medicare data (n = 18 956) without any precedent hematuria, bladder cancer or urinary tract infection claims (n = 12 195). The number of days to bladder cancer diagnosis was measured, as well as the impact of sex and presenting symptom on time to diagnosis, pathology, and oncological outcomes. The mean time to bladder cancer diagnosis was 72.2 days in women versus 58.9 days in men (P < 0.001). A logistic regression model identified the greatest predictors of ≥ pT2 pathology were both women (odds ratio 2.08, 95% confidence interval 1.70-2.55) and men (odds ratio 1.71, 95% confidence interval 1.49-1.97) presenting with urinary tract infection. Cox proportional hazards analysis identified an increased risk of mortality from bladder cancer and all causes in women presenting with urinary tract infection (hazard ratio 1.37, 95% confidence interval 1.10-1.71, and hazard ratio 1.47, 95% confidence interval 1.28-1.69) compared with women with hematuria. Women have a longer interval from urinary tract infection to diagnosis of bladder cancer. Urinary tract infection presentation can adversely affect time to diagnosis, pathology and survival. Time to diagnosis seems not to be an independent predictor of bladder cancer outcomes. © 2015 The Japanese Urological Association.
7 CFR 1709.12 - Reporting requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... To support Agency monitoring of project performance and use of grant funds, Grantees shall file... such times as provided in the grant agreement. (b) Project performance reports in such form and at such intervals as provided in the grant agreement. The project performance report shall compare accomplishments...
Scheduling with Automatic Resolution of Conflicts
NASA Technical Reports Server (NTRS)
Clement, Bradley; Schaffer, Steve
2006-01-01
DSN Requirement Scheduler is a computer program that automatically schedules, reschedules, and resolves conflicts for allocations of resources of NASA s Deep Space Network (DSN) on the basis of ever-changing project requirements for DSN services. As used here, resources signifies, primarily, DSN antennas, ancillary equipment, and times during which they are available. Examples of project-required DSN services include arraying, segmentation, very-long-baseline interferometry, and multiple spacecraft per aperture. Requirements can include periodic reservations of specific or optional resources during specific time intervals or within ranges specified in terms of starting times and durations. This program is built on the Automated Scheduling and Planning Environment (ASPEN) software system (aspects of which have been described in previous NASA Tech Briefs articles), with customization to reflect requirements and constraints involved in allocation of DSN resources. Unlike prior DSN-resource- scheduling programs that make single passes through the requirements and require human intervention to resolve conflicts, this program makes repeated passes in a continuing search for all possible allocations, provides a best-effort solution at any time, and presents alternative solutions among which users can choose.
Falcaro, Milena; Pickles, Andrew
2007-02-10
We focus on the analysis of multivariate survival times with highly structured interdependency and subject to interval censoring. Such data are common in developmental genetics and genetic epidemiology. We propose a flexible mixed probit model that deals naturally with complex but uninformative censoring. The recorded ages of onset are treated as possibly censored ordinal outcomes with the interval censoring mechanism seen as arising from a coarsened measurement of a continuous variable observed as falling between subject-specific thresholds. This bypasses the requirement for the failure times to be observed as falling into non-overlapping intervals. The assumption of a normal age-of-onset distribution of the standard probit model is relaxed by embedding within it a multivariate Box-Cox transformation whose parameters are jointly estimated with the other parameters of the model. Complex decompositions of the underlying multivariate normal covariance matrix of the transformed ages of onset become possible. The new methodology is here applied to a multivariate study of the ages of first use of tobacco and first consumption of alcohol without parental permission in twins. The proposed model allows estimation of the genetic and environmental effects that are shared by both of these risk behaviours as well as those that are specific. 2006 John Wiley & Sons, Ltd.
Leodori, Giorgio; Formica, Alessandra; Zhu, Xiaoying; Conte, Antonella; Belvisi, Daniele; Cruccu, Giorgio; Hallett, Mark; Berardelli, Alfredo
2017-10-01
The somatosensory temporal discrimination threshold (STDT) has been used in recent years to investigate time processing of sensory information, but little is known about the physiological correlates of somatosensory temporal discrimination. The objective of this study was to investigate whether the time interval required to discriminate between two stimuli varies according to the number of stimuli in the task. We used the third-stimulus temporal discrimination threshold (ThirdDT), defined as the shortest time interval at which an individual distinguishes a third stimulus following a pair of stimuli delivered at the STDT. The STDT and ThirdDT were assessed in 31 healthy subjects. In a subgroup of 10 subjects, we evaluated the effects of the stimuli intensity on the ThirdDT. In a subgroup of 16 subjects, we evaluated the effects of S1 continuous theta-burst stimulation (S1-cTBS) on the STDT and ThirdDT. Results show that ThirdDT is shorter than STDT. We found a positive correlation between STDT and ThirdDT values. As long as the stimulus intensity was within the perceivable and painless range, it did not affect ThirdDT values. S1-cTBS significantly affected both STDT and ThirdDT, although the latter was affected to a greater extent and for a longer period of time. We conclude that the interval needed to discriminate between time-separated tactile stimuli is related to the number of stimuli used in the task. STDT and ThirdDT are encoded in S1, probably by a shared tactile temporal encoding mechanism whose performance rapidly changes during the perception process. ThirdDT is a new method to measure somatosensory temporal discrimination. NEW & NOTEWORTHY To investigate whether the time interval required to discriminate between stimuli varies according to changes in the stimulation pattern, we used the third-stimulus temporal discrimination threshold (ThirdDT). We found that the somatosensory temporal discrimination acuity varies according to the number of stimuli in the task. The ThirdDT is a new method to measure somatosensory temporal discrimination and a possible index of inhibitory activity at the S1 level. Copyright © 2017 the American Physiological Society.
Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A
1994-01-01
In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.
Davis, N F; Murray, G; O'Connor, T; Browne, C; MacCraith, E; Galvin, D; Mulvin, D; Quinlan, D; Lennon, G
2017-11-01
A forgotten ureteric stent may result in severe renal impairment leading to nephrectomy. To compare the effectiveness of a centralised computerised registry for monitoring ureteric stent activity with a previously established theatre stent logbook system. This prospective audit was performed in two 9-monthly intervals. During the first interval, insertion/removal of a ureteric stent was documented in a specific theatre stent logbook. In the second interval, an electronic centralised computerised registry was developed to document insertion/removal of a ureteric stent onto an accessible hospital server. A computerised traffic-light system was also developed to identify patients with an indwelling stent for >3 months. The primary outcome variable was the number of prolonged indwelling ureteric stents in both groups. During the first time interval, 188 ureteric stents were inserted and 182 (96%) were removed or changed. Six (4%) patients underwent insertion of a ureteric stent for a prolonged period of time (>6 months). This subgroup required complex endourological intervention for stent removal due to encrustation. During the second time interval, 157 ureteric stents were inserted and all patients had their stent removed or changed within 6 months. No patients in this group were lost to follow-up. This study demonstrates that a centralised computerised ureteric stent registry is superior to a conventional logbook for monitoring ureteric stent activity. We propose the introduction a centralised nationalised ureteric stent registry for eliminating the potential for prolonged or forgotten ureteric stents.
Evaluation of Operational Procedures for Using a Time-Based Airborne Inter-arrival Spacing Tool
NASA Technical Reports Server (NTRS)
Oseguera-Lohr, Rosa M.; Lohr, Gary W.; Abbott, Terence S.; Eischeid, Todd M.
2002-01-01
An airborne tool has been developed based on the concept of an aircraft maintaining a time-based spacing interval from the preceding aircraft. The Advanced Terminal Area Approach Spacing (ATAAS) tool uses Automatic Dependent Surveillance-Broadcast (ADS-B) aircraft state data to compute a speed command for the ATAAS-equipped aircraft to obtain a required time interval behind another aircraft. The tool and candidate operational procedures were tested in a high-fidelity, full mission simulator with active airline subject pilots flying an arrival scenario using three different modes for speed control. The objectives of this study were to validate the results of a prior Monte Carlo analysis of the ATAAS algorithm and to evaluate the concept from the standpoint of pilot acceptability and workload. Results showed that the aircraft was able to consistently achieve the target spacing interval within one second (the equivalent of approximately 220 ft at a final approach speed of 130 kt) when the ATAAS speed guidance was autothrottle-coupled, and a slightly greater (4-5 seconds), but consistent interval with the pilot-controlled speed modes. The subject pilots generally rated the workload level with the ATAAS procedure as similar to that with standard procedures, and also rated most aspects of the procedure high in terms of acceptability. Although pilots indicated that the head-down time was higher with ATAAS, the acceptability of head-down time was rated high. Oculometer data indicated slight changes in instrument scan patterns, but no significant change in the amount of time spent looking out the window between the ATAAS procedure versus standard procedures.
Variance of discharge estimates sampled using acoustic Doppler current profilers from moving boats
Garcia, Carlos M.; Tarrab, Leticia; Oberg, Kevin; Szupiany, Ricardo; Cantero, Mariano I.
2012-01-01
This paper presents a model for quantifying the random errors (i.e., variance) of acoustic Doppler current profiler (ADCP) discharge measurements from moving boats for different sampling times. The model focuses on the random processes in the sampled flow field and has been developed using statistical methods currently available for uncertainty analysis of velocity time series. Analysis of field data collected using ADCP from moving boats from three natural rivers of varying sizes and flow conditions shows that, even though the estimate of the integral time scale of the actual turbulent flow field is larger than the sampling interval, the integral time scale of the sampled flow field is on the order of the sampling interval. Thus, an equation for computing the variance error in discharge measurements associated with different sampling times, assuming uncorrelated flow fields is appropriate. The approach is used to help define optimal sampling strategies by choosing the exposure time required for ADCPs to accurately measure flow discharge.
Gooch, Cynthia M.; Stern, Yaakov; Rakitin, Brian C.
2009-01-01
The effect of aging on interval timing was examined using a choice time production task, which required participants to choose a key response based on the location of the stimulus, but to delay responding until after a learned time interval. Experiment 1 varied attentional demands of the response choice portion of the task by varying difficulty of stimulus-response mapping. Choice difficulty affected temporal accuracy equally in both age groups, but older participants’ response latencies were more variable under more difficult response choice conditions. Experiment 2 tested the contribution of long-term memory to differences in choice time production between age groups over 3 days of testing. Direction of errors in time production between the two age groups diverged over the 3 sessions, but variability did not differ. Results from each experiment separately show age-related changes to attention and memory in temporal processing using different measures and manipulations in the same task. PMID:19132578
Preschool Children's Control of Action Outcomes
ERIC Educational Resources Information Center
Freier, Livia; Cooper, Richard P.; Mareschal, Denis
2017-01-01
Naturalistic goal-directed behaviours require the engagement and maintenance of appropriate levels of cognitive control over relatively extended intervals of time. In two experiments, we examined preschool children's abilities to maintain top-down control throughout the course of a sequential task. Both 3- and 5-year-olds demonstrated good…
The fast and the slow of skilled bimanual rhythm production: parallel versus integrated timing.
Krampe, R T; Kliegl, R; Mayr, U; Engbert, R; Vorberg, D
2000-02-01
Professional pianists performed 2 bimanual rhythms at a wide range of different tempos. The polyrhythmic task required the combination of 2 isochronous sequences (3 against 4) between the hands; in the syncopated rhythm task successive keystrokes formed intervals of identical (isochronous) durations. At slower tempos, pianists relied on integrated timing control merging successive intervals between the hands into a common reference frame. A timer-motor model is proposed based on the concepts of rate fluctuation and the distinction between target specification and timekeeper execution processes as a quantitative account of performance at slow tempos. At rapid rates expert pianists used hand-independent, parallel timing control. In alternative to a model based on a single central clock, findings support a model of flexible control structures with multiple timekeepers that can work in parallel to accommodate specific task constraints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azunre, P.
Here in this paper, two novel techniques for bounding the solutions of parametric weakly coupled second-order semilinear parabolic partial differential equations are developed. The first provides a theorem to construct interval bounds, while the second provides a theorem to construct lower bounds convex and upper bounds concave in the parameter. The convex/concave bounds can be significantly tighter than the interval bounds because of the wrapping effect suffered by interval analysis in dynamical systems. Both types of bounds are computationally cheap to construct, requiring solving auxiliary systems twice and four times larger than the original system, respectively. An illustrative numerical examplemore » of bound construction and use for deterministic global optimization within a simple serial branch-and-bound algorithm, implemented numerically using interval arithmetic and a generalization of McCormick's relaxation technique, is presented. Finally, problems within the important class of reaction-diffusion systems may be optimized with these tools.« less
Long-term engagement in smoking cessation counseling among rural smokers.
Cupertino, A Paula; Mahnken, Jonathan D; Richter, Kimber; Cox, Lisa Sanderson; Casey, Genevieve; Resnicow, Ken; Ellerbeck, Edward F
2007-11-01
Effective smoking cessation treatment requires active patient engagement. This may be particularly important for rural smokers who have less access to smoking cessation resources than others. This study describes long-term engagement in counseling for smoking cessation and factors associated with engagement. As part of a randomized trial, 231 rural smokers received up to 6 telephone-based counseling sessions at 6-month intervals over 24 months. Engagement in treatment was categorized according to the number of counseling calls each interval. During the final 6-month interval, more than 60% of continuing smokers remained engaged in treatment. Call completion varied over time; while levels of engagement dropped after the first interval, many continuing smokers remained engaged throughout the study. Education, age, motivation, income, diabetes, and health insurance status were predictors of treatment engagement. This study demonstrates that smokers will remain engaged in long-term counseling designed to address the chronic nature of nicotine dependence.
NASA Technical Reports Server (NTRS)
Mcenulty, R. E.
1977-01-01
The G189A simulation of the Shuttle Orbiter ECLSS was upgraded. All simulation library versions and simulation models were converted from the EXEC2 to the EXEC8 computer system and a new program, G189PL, was added to the combination master program library. The program permits the post-plotting of up to 100 frames of plot data over any time interval of a G189 simulation run. The overlay structure of the G189A simulations were restructured for the purpose of conserving computer core requirements and minimizing run time requirements.
SINGLE-INTERVAL GAS PERMEABILITY ESTIMATION
Single-interval, steady-steady-state gas permeability testing requires estimation of pressure at a screened interval which in turn requires measurement of friction factors as a function of mass flow rate. Friction factors can be obtained by injecting air through a length of pipe...
Realtime Multichannel System for Beat to Beat QT Interval Variability
NASA Technical Reports Server (NTRS)
Starc, Vito; Schlegel, Todd T.
2006-01-01
The measurement of beat-to-beat QT interval variability (QTV) shows clinical promise for identifying several types of cardiac pathology. However, until now, there has been no device capable of displaying, in real time on a beattobeat basis, changes in QTV in all 12 conventional leads in a continuously monitored patient. While several software programs have been designed to analyze QTV, heretofore, such programs have all involved only a few channels (at most) and/or have required laborious user interaction or offline calculations and postprocessing, limiting their clinical utility. This paper describes a PC-based ECG software program that in real time, acquires, analyzes and displays QTV and also PQ interval variability (PQV) in each of the eight independent channels that constitute the 12lead conventional ECG. The system also processes certain related signals that are derived from singular value decomposition and that help to reduce the overall effects of noise on the realtime QTV and PQV results.
Near-Term Fetuses Process Temporal Features of Speech
ERIC Educational Resources Information Center
Granier-Deferre, Carolyn; Ribeiro, Aurelie; Jacquet, Anne-Yvonne; Bassereau, Sophie
2011-01-01
The perception of speech and music requires processing of variations in spectra and amplitude over different time intervals. Near-term fetuses can discriminate acoustic features, such as frequencies and spectra, but whether they can process complex auditory streams, such as speech sequences and more specifically their temporal variations, fast or…
USDA-ARS?s Scientific Manuscript database
The 2015 Dietary Guidelines Advisory Committee indicated magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially...
Aircraft Inspection for the General Aviation Aircraft Owner.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
Presented is useful information for owners, pilots, student mechanics, and others with aviation interests. Part I of this booklet outlines aircraft inspection requirements, owner responsibilities, inspection time intervals, and sources of basic information. Part II is concerned with the general techniques used to inspect an aircraft. (Author/JN)
A digital indicator for maximum windspeeds.
William B. Fowler
1969-01-01
A simple device for indicating maximum windspeed during a time interval is described. Use of a unijunction transistor, for voltage sensing, results in a stable comparison circuit and also reduces overall component requirements. Measurement is presented digitally in 1-mile-per-hour increments over the range of 0-51 m.p.h.
Phylogenetic diversity measures based on Hill numbers.
Chao, Anne; Chiu, Chun-Huo; Jost, Lou
2010-11-27
We propose a parametric class of phylogenetic diversity (PD) measures that are sensitive to both species abundance and species taxonomic or phylogenetic distances. This work extends the conventional parametric species-neutral approach (based on 'effective number of species' or Hill numbers) to take into account species relatedness, and also generalizes the traditional phylogenetic approach (based on 'total phylogenetic length') to incorporate species abundances. The proposed measure quantifies 'the mean effective number of species' over any time interval of interest, or the 'effective number of maximally distinct lineages' over that time interval. The product of the measure and the interval length quantifies the 'branch diversity' of the phylogenetic tree during that interval. The new measures generalize and unify many existing measures and lead to a natural definition of taxonomic diversity as a special case. The replication principle (or doubling property), an important requirement for species-neutral diversity, is generalized to PD. The widely used Rao's quadratic entropy and the phylogenetic entropy do not satisfy this essential property, but a simple transformation converts each to our measures, which do satisfy the property. The proposed approach is applied to forest data for interpreting the effects of thinning.
Proceedings of the 8th Precise Time and Time Interval (PTTI) Applications and Planning Meeting
NASA Technical Reports Server (NTRS)
1977-01-01
The Proceedings contain the papers presented at the Eight Annual Precise Time and Tme Interval PTTI Applications and Planning Meeting. The edited record of the discussions following the papers and the panel discussions are also included. This meeting provided a forum for the exchange of information on precise time and frequency technology among members of the scientific community and persons with program applications. The 282 registered attendees came from various U.S. Government agencies, private industry, universities and a number of foreign countries were represented. In this meeting, papers were presented that emphasized: (1) definitions and international regulations of precise time sources and users, (2) the scientific foundations of Hydrogen Maser standards, the current developments in this field and the application experience, and (3) how to measure the stability performance properties of precise standards. As in the previous meetings, update and new papers were presented on system applications with past, present and future requirements identified.
Reasoning about real-time systems with temporal interval logic constraints on multi-state automata
NASA Technical Reports Server (NTRS)
Gabrielian, Armen
1991-01-01
Models of real-time systems using a single paradigm often turn out to be inadequate, whether the paradigm is based on states, rules, event sequences, or logic. A model-based approach to reasoning about real-time systems is presented in which a temporal interval logic called TIL is employed to define constraints on a new type of high level automata. The combination, called hierarchical multi-state (HMS) machines, can be used to model formally a real-time system, a dynamic set of requirements, the environment, heuristic knowledge about planning-related problem solving, and the computational states of the reasoning mechanism. In this framework, mathematical techniques were developed for: (1) proving the correctness of a representation; (2) planning of concurrent tasks to achieve goals; and (3) scheduling of plans to satisfy complex temporal constraints. HMS machines allow reasoning about a real-time system from a model of how truth arises instead of merely depending of what is true in a system.
Does controlling for biological maturity improve physical activity tracking?
Erlandson, Marta C; Sherar, Lauren B; Mosewich, Amber D; Kowalski, Kent C; Bailey, Donald A; Baxter-Jones, Adam D G
2011-05-01
Tracking of physical activity through childhood and adolescence tends to be low. Variation in the timing of biological maturation within youth of the same chronological age (CA) might affect participation in physical activity and may partially explain the low tracking. To examine the stability of physical activity over time from childhood to late adolescence when aligned on CA and biological age (BA). A total of 91 males and 96 females aged 8-15 yr from the Saskatchewan Pediatric Bone Mineral Accrual Study (PBMAS) were assessed annually for 8 yr. BA was calculated as years from age at peak height velocity. Physical activity was assessed using the Physical Activity Questionnaire for Children/Adolescents. Tracking was analyzed using intraclass correlations for both CA and BA (2-yr groupings). To be included in the analysis, an individual required a measure at both time points within an interval; however, not all individuals were present at all tracking intervals. Physical activity tracking by CA 2-yr intervals were, in general, moderate in males (r=0.42-0.59) and females (r=0.43-0.44). However, the 9- to 11-yr CA interval was low and nonsignificant (r=0.23-0.30). Likewise, tracking of physical activity by BA 2-yr intervals was moderate to high in males (r=0.44-0.60) and females (r=0.39-0.62). Accounting for differences in the timing of biological maturity had little effect on tracking physical activity. However, point estimates for tracking are higher in early adolescence in males and to a greater extent in females when aligned by BA versus CA. This suggests that maturity may be more important in physical activity participation in females than males. © 2011 by the American College of Sports Medicine
Welfare, maternal work, and on-time childhood vaccination rates.
Sohn, Min-Woong; Yoo, Joan; Oh, Elissa H; Amsden, Laura B; Holl, Jane L
2011-12-01
To examine effects of Temporary Assistance for Needy Families welfare cash assistance and maternal work requirements on "on-time" childhood vaccination rates. A stratified random sample of Illinois children from low-income families affected by welfare reform was monitored from 1997 to 2004. Medical records from pediatricians' offices and Medicaid claims data were used to identify the timeliness of 18 recommended vaccinations. Random-intercept logistic models were used to estimate on-time vaccine administration as a function of welfare receipt and maternal work with adjustment for characteristics of the children and mothers and time-varying covariates pertaining to the administration window for each recommended vaccine dose. Of all recommended vaccinations, 55.9% were administered on time. On-time vaccination rates were higher when families were receiving welfare than not (57.4% vs 52.8%). Children in families that either were receiving welfare or had working mothers were 1.7 to 2.1 times more likely to receive vaccinations on time compared with children in families that were not receiving welfare and did not have working mothers. When vaccine doses were stratified according to welfare status, maternal work was associated with decreased on-time vaccination rates (odds ratio: 0.73 [95% confidence interval: 0.59-0.90]) when families received welfare but increased on-time vaccination rates (odds ratio: 1.68 [95% confidence interval: 1.27-2.22]) when they did not receive welfare. These results indicate that maternal work requirements of Temporary Assistance for Needy Families had negative effects on timely administration of childhood vaccinations, although receipt of welfare itself was associated with increased on-time rates.
NASA Technical Reports Server (NTRS)
Levy, G. F.; Sonenshine, D. E.; Czoch, J. K.
1976-01-01
Transpiration rates of loblolly pine (Pinus taeda L.) and sweetgum (Liquidambar styraciflua L.) were measured at two different atmospheric water vapor pressure deficits (V.P.D.) in a controlled environment growth chamber using tritiated water as a tracer. The trees were maintained in a sealed plant bed containing a hydroponic nutrient solution into which labeled water (spike) was introduced. Samples of leaves, chamber air, spiked nutrient solution and control water were assayed for ratio-activity using liquid scintillation techniques to determine transpiration rates. The transpiration rate of sweetgum in ml./hr./gm. (4.95) was found to be 5 times greater than that of loblolly pine (1.03) at 1.84 V.P.D. and 8 times greater at 6.74 V.P.D. (15.99 for sweetgum vs. 2.19 for pine). Transpiration (based on measurements of leaf radioactivity) in both species rose with increasing deficit; however sweetgum increased its output by 3 times while pine only doubled its rate. Cyclical changes in transpiration rates were noted in both species; the sweetgum cycle required a 6 hour interval whereas the pine cycle required a 9 hour interval.
NASA Technical Reports Server (NTRS)
Roman, Monserrate C.; Jones, Kathy U.; Oubre, Cherie M.; Castro, Victoria; Ott, Mark C.; Birmele, Michele; Venkateswaran, Kasthuri J.; Vaishampayan, Parag A.
2013-01-01
Current methods for microbial detection: a) Labor & time intensive cultivation-based approaches that can fail to detect or characterize all cells present. b) Requires collection of samples on orbit and transportation back to ground for analysis. Disadvantages to current detection methods: a) Unable to perform quick and reliable detection on orbit. b) Lengthy sampling intervals. c) No microbe identification.
Synchronization for Optical PPM Signals
NASA Technical Reports Server (NTRS)
Vilnrotter, V. A.
1985-01-01
Method based on statistical properties of weak pulse-positionmodulated (PPM) signal enables synchronization of receiver clock with received-signal time base. Method applies to weak optical M-ary PPM signals, for which there is only one pulse of length Tp transmitted during one of timeslots of length T in each successive interval of M timeslots. Method requires small dead time, Td, at beginning and end of each timeslot, during which pulse amplitude is zero.
Hwang, Taik Gun; Lee, Younsuk; Shin, Hojung
2011-01-01
The efficiency and quality of a healthcare system can be defined as interactions among the system structure, processes, and outcome. This article examines the effect of structural adjustment (change in floor plan or layout) and process improvement (critical pathway implementation) on performance of emergency room (ER) operations for acute cerebral infarction patients. Two large teaching hospitals participated in this study: Korea University (KU) Guro Hospital and KU Anam Hospital. The administration of Guro adopted a structure-oriented approach in improving its ER operations while the administration of Anam employed a process-oriented approach, facilitating critical pathways and protocols. To calibrate improvements, the data for time interval, length of stay, and hospital charges were collected, before and after the planned changes were implemented at each hospital. In particular, time interval is the most essential measure for handling acute stroke patients because patients' survival and recovery are affected by the promptness of diagnosis and treatment. Statistical analyses indicated that both redesign of layout at Guro and implementation of critical pathways at Anam had a positive influence on most of the performance measures. However, reduction in time interval was not consistent at Guro, demonstrating delays in processing time for a few processes. The adoption of critical pathways at Anam appeared more effective in reducing time intervals than the structural rearrangement at Guro, mainly as a result of the extensive employee training required for a critical pathway implementation. Thus, hospital managers should combine structure-oriented and process-oriented strategies to maximize effectiveness of improvement efforts.
Lee, Jung Hwan; Lee, Sang-Ho
2016-07-01
Epidural steroid injection (ESI) is known to be an effective treatment for neck or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after single ESI, there has been little evidence supporting the usefulness of this procedure. The purpose of this study, therefore, was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than intermittent ESI performed only when pain was aggravated. One hundred eighty-four patients who underwent transforaminal ESI (TFESI) for treatment of axial neck and radicular arm pain due to HIVD or SS and could be followed up for 1 year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (numeric rating scale (NRS) ≥ 3 after the first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 76) comprised partial responders who did not receive repeat injection at the prescribed interval, but received intermittent injections only for aggravation of pain. Various clinical data were assessed, including total number of injections during 1 year, NRS duration of <3 during 1 year (NRS < 3 duration), and time interval until pain was increased to require additional injections after repeat injection in Group A, or after first injection in Group B (time to reinjection). Groups A and B were compared in terms of total population, HIVD, and SS. In the whole population, HIVD subgroup, and SS subgroup, patients in Group A required significantly fewer injections to obtain satisfactory pain relief during the 1-year follow-up period. Group A showed a significantly longer time to reinjection and longer NRS < 3 than Group B did. Repeat TFESI conducted at 2- to 3-week intervals after the first injection in partial responders contributed to greater clinical benefit compared with intermittent TFESI performed only upon pain aggravation, with fewer TFESI sessions.
Babulal, Ganesh M; Addison, Aaron; Ghoshal, Nupur; Stout, Sarah H; Vernon, Elizabeth K; Sellan, Mark; Roe, Catherine M
2016-01-01
Background : The number of older adults in the United States will double by 2056. Additionally, the number of licensed drivers will increase along with extended driving-life expectancy. Motor vehicle crashes are a leading cause of injury and death in older adults. Alzheimer's disease (AD) also negatively impacts driving ability and increases crash risk. Conventional methods to evaluate driving ability are limited in predicting decline among older adults. Innovations in GPS hardware and software can monitor driving behavior in the actual environments people drive in. Commercial off-the-shelf (COTS) devices are affordable, easy to install and capture large volumes of data in real-time. However, adapting these methodologies for research can be challenging. This study sought to adapt a COTS device and determine an interval that produced accurate data on the actual route driven for use in future studies involving older adults with and without AD. Methods : Three subjects drove a single course in different vehicles at different intervals (30, 60 and 120 seconds), at different times of day, morning (9:00-11:59AM), afternoon (2:00-5:00PM) and night (7:00-10pm). The nine datasets were examined to determine the optimal collection interval. Results : Compared to the 120-second and 60-second intervals, the 30-second interval was optimal in capturing the actual route driven along with the lowest number of incorrect paths and affordability weighing considerations for data storage and curation. Discussion : Use of COTS devices offers minimal installation efforts, unobtrusive monitoring and discreet data extraction. However, these devices require strict protocols and controlled testing for adoption into research paradigms. After reliability and validity testing, these devices may provide valuable insight into daily driving behaviors and intraindividual change over time for populations of older adults with and without AD. Data can be aggregated over time to look at changes or adverse events and ascertain if decline in performance is occurring.
Hilsabeck, T. J.; Frenje, J. A.; Hares, J. D.; ...
2016-08-02
Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording.more » Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hilsabeck, T. J.; Frenje, J. A.; Hares, J. D.
Here we present a time-resolved detector concept for the magnetic recoil spectrometer for time-resolved measurements of the NIF neutron spectrum. The measurement is challenging due to the time spreading of the recoil protons (or deuterons) as they transit an energy dispersing magnet system. Ions arrive at the focal plane of the magnetic spectrometer over an interval of tens of nanoseconds. We seek to measure the time-resolved neutron spectrum with 20 ps precision by manipulating an electron signal derived from the ions. A stretch-compress scheme is employed to remove transit time skewing while simultaneously reducing the bandwidth requirements for signal recording.more » Simulation results are presented along with design concepts for structures capable of establishing the required electromagnetic fields.« less
Levine, Judah
2016-01-01
A method is presented for synchronizing the time of a clock to a remote time standard when the channel connecting the two has significant delay variation that can be described only statistically. The method compares the Allan deviation of the channel fluctuations to the free-running stability of the local clock, and computes the optimum interval between requests based on one of three selectable requirements: (1) choosing the highest possible accuracy, (2) choosing the best tradeoff of cost vs. accuracy, or (3) minimizing the number of requests to realize a specific accuracy. Once the interval between requests is chosen, the final step is to steer the local clock based on the received data. A typical adjustment algorithm, which supports both the statistical considerations based on the Allan deviation comparison and the timely detection of errors is included as an example. PMID:26529759
Gates, Timothy J; Noyce, David A
2016-11-01
This manuscript describes the development and evaluation of a conceptual framework for real-time operation of dynamic on-demand extension of the red clearance interval as a countermeasure for red-light-running. The framework includes a decision process for determining, based on the real-time status of vehicles arriving at the intersection, when extension of the red clearance interval should occur and the duration of each extension. A zonal classification scheme was devised to assess whether an approaching vehicle requires additional time to safely clear the intersection based on the remaining phase time, type of vehicle, current speed, and current distance from the intersection. Expected performance of the conceptual framework was evaluated through modeling of replicated field operations using vehicular event data collected as part of this research. The results showed highly accurate classification of red-light-running vehicles needing additional clearance time and relatively few false extension calls from stopping vehicles, thereby minimizing the expected impacts to signal and traffic operations. Based on the recommended parameters, extension calls were predicted to occur once every 26.5cycles. Assuming a 90scycle, 1.5 extensions per hour were expected per approach, with an estimated extension time of 2.30s/h. Although field implementation was not performed, it is anticipated that long-term reductions in targeted red-light-running conflicts and crashes will likely occur if red clearance interval extension systems are implemented at locations where start-up delay on the conflicting approach is generally minimal, such as intersections with lag left-turn phasing. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dynamics of Stability of Orientation Maps Recorded with Optical Imaging.
Shumikhina, S I; Bondar, I V; Svinov, M M
2018-03-15
Orientation selectivity is an important feature of visual cortical neurons. Optical imaging of the visual cortex allows for the generation of maps of orientation selectivity that reflect the activity of large populations of neurons. To estimate the statistical significance of effects of experimental manipulations, evaluation of the stability of cortical maps over time is required. Here, we performed optical imaging recordings of the visual cortex of anesthetized adult cats. Monocular stimulation with moving clockwise square-wave gratings that continuously changed orientation and direction was used as the mapping stimulus. Recordings were repeated at various time intervals, from 15 min to 16 h. Quantification of map stability was performed on a pixel-by-pixel basis using several techniques. Map reproducibility showed clear dynamics over time. The highest degree of stability was seen in maps recorded 15-45 min apart. Averaging across all time intervals and all stimulus orientations revealed a mean shift of 2.2 ± 0.1°. There was a significant tendency for larger shifts to occur at longer time intervals. Shifts between 2.8° (mean ± 2SD) and 5° were observed more frequently at oblique orientations, while shifts greater than 5° appeared more frequently at cardinal orientations. Shifts greater than 5° occurred rarely overall (5.4% of cases) and never exceeded 11°. Shifts of 10-10.6° (0.7%) were seen occasionally at time intervals of more than 4 h. Our findings should be considered when evaluating the potential effect of experimental manipulations on orientation selectivity mapping studies. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.
Coupling between perception and action timing during sensorimotor synchronization.
Serrien, Deborah J; Spapé, Michiel M
2010-12-17
Time is an important parameter in behaviour, especially when synchronization with external events is required. To evaluate the nature of the association between perception and action timing, this study introduced pitch accented tones during performance of a sensorimotor tapping task. Furthermore, regularity of the pacing cues was modified by small (subliminal) or large (conscious) timing perturbations. A global analysis across the intervals showed that repeated accented tones increased the tap-tone asynchrony in the regular (control) and irregular (subliminal) trials but not in the irregular trials with awareness of the perturbations. Asynchrony variability demonstrated no effect of accentuation in the regular and subliminal irregular trials, whereas it increased in the conscious irregular trials. A local analysis of the intervals showed that pitch accentuation lengthened the duration of the tapping responses, but only in the irregular trials with large timing perturbations. These data underline that common timing processes are automatically engaged for perception and action, although this arrangement can be overturned by cognitive intervention. Overall, the findings highlight a flexible association between perception and action timing within a functional information processing framework. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Epstein, Richard H; Dexter, Franklin; Hofer, Ira S; Rodriguez, Luis I; Schwenk, Eric S; Maga, Joni M; Hindman, Bradley J
2018-02-01
Perioperative hypothermia may increase the incidences of wound infection, blood loss, transfusion, and cardiac morbidity. US national quality programs for perioperative normothermia specify the presence of at least 1 "body temperature" ≥35.5°C during the interval from 30 minutes before to 15 minutes after the anesthesia end time. Using data from 4 academic hospitals, we evaluated timing and measurement considerations relevant to the current requirements to guide hospitals wishing to report perioperative temperature measures using electronic data sources. Anesthesia information management system databases from 4 hospitals were queried to obtain intraoperative temperatures and intervals to the anesthesia end time from discontinuation of temperature monitoring, end of surgery, and extubation. Inclusion criteria included age >16 years, use of a tracheal tube or supraglottic airway, and case duration ≥60 minutes. The end-of-case temperature was determined as the maximum intraoperative temperature recorded within 30 minutes before the anesthesia end time (ie, the temperature that would be used for reporting purposes). The fractions of cases with intervals >30 minutes between the last intraoperative temperature and the anesthesia end time were determined. Among the hospitals, averages (binned by quarters) of 34.5% to 59.5% of cases had intraoperative temperature monitoring discontinued >30 minutes before the anesthesia end time. Even if temperature measurement had been continued until extubation, averages of 5.9% to 20.8% of cases would have exceeded the allowed 30-minute window. Averages of 8.9% to 21.3% of cases had end-of-case intraoperative temperatures <35.5°C (ie, a quality measure failure). Because of timing considerations, a substantial fraction of cases would have been ineligible to use the end-of-case intraoperative temperature for national quality program reporting. Thus, retrieval of postanesthesia care unit temperatures would have been necessary. A substantive percentage of cases had end-of-case intraoperative temperatures below the 35.5°C threshold, also requiring postoperative measurement to determine whether the quality measure was satisfied. Institutions considering reporting national quality measures for perioperative normothermia should consider the technical and logistical issues identified to achieve a high level of compliance based on the specified regulatory language.
Petersen, Christian C; Mistlberger, Ralph E
2017-08-01
The mechanisms that enable mammals to time events that recur at 24-h intervals (circadian timing) and at arbitrary intervals in the seconds-to-minutes range (interval timing) are thought to be distinct at the computational and neurobiological levels. Recent evidence that disruption of circadian rhythmicity by constant light (LL) abolishes interval timing in mice challenges this assumption and suggests a critical role for circadian clocks in short interval timing. We sought to confirm and extend this finding by examining interval timing in rats in which circadian rhythmicity was disrupted by long-term exposure to LL or by chronic intake of 25% D 2 O. Adult, male Sprague-Dawley rats were housed in a light-dark (LD) cycle or in LL until free-running circadian rhythmicity was markedly disrupted or abolished. The rats were then trained and tested on 15- and 30-sec peak-interval procedures, with water restriction used to motivate task performance. Interval timing was found to be unimpaired in LL rats, but a weak circadian activity rhythm was apparently rescued by the training procedure, possibly due to binge feeding that occurred during the 15-min water access period that followed training each day. A second group of rats in LL were therefore restricted to 6 daily meals scheduled at 4-h intervals. Despite a complete absence of circadian rhythmicity in this group, interval timing was again unaffected. To eliminate all possible temporal cues, we tested a third group of rats in LL by using a pseudo-randomized schedule. Again, interval timing remained accurate. Finally, rats tested in LD received 25% D 2 O in place of drinking water. This markedly lengthened the circadian period and caused a failure of LD entrainment but did not disrupt interval timing. These results indicate that interval timing in rats is resistant to disruption by manipulations of circadian timekeeping previously shown to impair interval timing in mice.
Estimating times of extinction in the fossil record
Marshall, Charles R.
2016-01-01
Because the fossil record is incomplete, the last fossil of a taxon is a biased estimate of its true time of extinction. Numerous methods have been developed in the palaeontology literature for estimating the true time of extinction using ages of fossil specimens. These methods, which typically give a confidence interval for estimating the true time of extinction, differ in the assumptions they make and the nature and amount of data they require. We review the literature on such methods and make some recommendations for future directions. PMID:27122005
Estimating times of extinction in the fossil record.
Wang, Steve C; Marshall, Charles R
2016-04-01
Because the fossil record is incomplete, the last fossil of a taxon is a biased estimate of its true time of extinction. Numerous methods have been developed in the palaeontology literature for estimating the true time of extinction using ages of fossil specimens. These methods, which typically give a confidence interval for estimating the true time of extinction, differ in the assumptions they make and the nature and amount of data they require. We review the literature on such methods and make some recommendations for future directions. © 2016 The Author(s).
USDA-ARS?s Scientific Manuscript database
Assessment of beef cow energy balance and efficiency in grazing-extensive rangelands has occurred on a nominal basis over short time intervals and has not accounted for the complexity of metabolic and digestive responses; behavioral adaptations to climatic, terrain, and vegetation variables; and doc...
40 CFR 63.704 - Compliance and monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... nonregenerative carbon adsorber is used to comply with § 63.703(c)(1), the site-specific operating parameter value... compliance with § 63.703(c), (e)(1)(i), or (f)(1)(i), as appropriate. (5) For each nonregenerative carbon... site-specific operating parameter the carbon replacement time interval, as determined by the maximum...
40 CFR 63.704 - Compliance and monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... nonregenerative carbon adsorber is used to comply with § 63.703(c)(1), the site-specific operating parameter value... compliance with § 63.703(c), (e)(1)(i), or (f)(1)(i), as appropriate. (5) For each nonregenerative carbon... site-specific operating parameter the carbon replacement time interval, as determined by the maximum...
40 CFR 63.704 - Compliance and monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... nonregenerative carbon adsorber is used to comply with § 63.703(c)(1), the site-specific operating parameter value... compliance with § 63.703(c), (e)(1)(i), or (f)(1)(i), as appropriate. (5) For each nonregenerative carbon... site-specific operating parameter the carbon replacement time interval, as determined by the maximum...
40 CFR 63.704 - Compliance and monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... nonregenerative carbon adsorber is used to comply with § 63.703(c)(1), the site-specific operating parameter value... compliance with § 63.703(c), (e)(1)(i), or (f)(1)(i), as appropriate. (5) For each nonregenerative carbon... site-specific operating parameter the carbon replacement time interval, as determined by the maximum...
40 CFR 63.704 - Compliance and monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... nonregenerative carbon adsorber is used to comply with § 63.703(c)(1), the site-specific operating parameter value... compliance with § 63.703(c), (e)(1)(i), or (f)(1)(i), as appropriate. (5) For each nonregenerative carbon... site-specific operating parameter the carbon replacement time interval, as determined by the maximum...
Cardiotachometer displays heart rate on a beat-to-beat basis
NASA Technical Reports Server (NTRS)
Rasquin, J. R.; Smith, H. E.; Taylor, R. A.
1974-01-01
Electronics for this system may be chosen so that complete calculation and display may be accomplished in a few milliseconds, far less than even the fastest heartbeat interval. Accuracy may be increased, if desired, by using higher-frequency timing oscillator, although this will require large capacity registers at increased cost.
The Amygdalo-Nigrostriatal Network Is Critical for an Optimal Temporal Performance
ERIC Educational Resources Information Center
Es-seddiqi, Mouna; El Massioui, Nicole; Samson, Nathalie; Brown, Bruce L.; Doyère, Valérie
2016-01-01
The amygdalo-nigrostriatal (ANS) network plays an essential role in enhanced attention to significant events. Interval timing requires attention to temporal cues. We assessed rats having a disconnected ANS network, due to contralateral lesions of the medial central nucleus of the amygdala (CEm) and dopaminergic afferents to the lateral striatum,…
76 FR 22316 - Airworthiness Directives; Pacific Aerospace Limited Model 750XL Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-21
... pedal assemblies for cracks and incorporating a modification repair scheme if any cracks are found. You... cracks and incorporating a modification repair scheme if any cracks are found. You may obtain further... intervals not to exceed 300 hours time-in-service (TIS) until the modification repair scheme required in...
47 CFR 15.709 - General technical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... to the transmit antenna. If transmitting antennas of directional gain greater than 6 dBi are used, the maximum conducted output power shall be reduced by the amount in dB that the directional gain of... 100 kHz band during any time interval of continuous transmission: (i) Fixed devices: 12.2 dBm. (ii...
Examination of time series through randomly broken windows. [space observations from earth
NASA Technical Reports Server (NTRS)
Sturrock, P. A.
1980-01-01
The effect of irregular interruption of data collection (the breaking of the window function) on the spectrum determination of a time series is investigated. It is assumed that there is a uniform probability p that each interval of length tau, of the total interval of length T = tau, yields no data. For the linear case (Fourier transform) it is found that the noise to signal ratio has a (one sigma) value less than epsilon if N exceeds p(-1) (1-p) epsilon (-2). For the quadratic case, the same requirement is met by the less restrictive requirement that N exceed p(-1) (1-p) epsilon (-1). It appears that, if four observatories spaced around the Earth were to operate for 25 days, each for six hours a day (N = 100), and if the probability of cloud cover at any site on any day is 20% (p = 0.8), the r.m.s. noise to signal ratio is 0.25% for frequencies displaced from a sharp strong signal by 15 micro Hz. The noise to signal ratio drops off rapidly if the frequency offset exceeds 15 micro Hz.
Pediatric magnet ingestions: the dark side of the force.
Brown, Julie C; Otjen, Jeffrey P; Drugas, George T
2014-05-01
Pediatric magnet ingestions are increasing. Commercial availability of rare-earth magnets poses a serious health risk. This study defines incidence, characteristics, and management of ingestions over time. Cases were identified by searching radiology reports from June 2002 to December 2012 at a children's hospital and verified by chart and imaging review. Relative risk (RR) regressions determined changes in incidence and interventions over time. In all, 98% of ingestions occurred since 2006; 57% involved multiple magnets. Median age was 8 years (range 0 to 18); 0% of single and 56% of multiple ingestions required intervention. Compared with 2007 to 2009, ingestions increased from 2010 to 2012 (RR = 1.9, 95% confidence interval 1.2 to 3.0). Intervention proportion was unchanged (RR = .94, 95% confidence interval .4 to 2.2). Small spherical magnets comprised 26.8% of ingestions since 2010; 86% involved multiple magnets and 47% required intervention. Pediatric magnet ingestions and interventions have increased. Multiple ingestions prompt more imaging and surgical interventions. Magnet safety standards are needed to decrease risk to children. Copyright © 2014 Elsevier Inc. All rights reserved.
Koerbin, G; Cavanaugh, J A; Potter, J M; Abhayaratna, W P; West, N P; Glasgow, N; Hawkins, C; Armbruster, D; Oakman, C; Hickman, P E
2015-02-01
Development of reference intervals is difficult, time consuming, expensive and beyond the scope of most laboratories. The Aussie Normals study is a direct a priori study to determine reference intervals in healthy Australian adults. All volunteers completed a health and lifestyle questionnaire and exclusion was based on conditions such as pregnancy, diabetes, renal or cardiovascular disease. Up to 91 biochemical analyses were undertaken on a variety of analytical platforms using serum samples collected from 1856 volunteers. We report on our findings for 40 of these analytes and two calculated parameters performed on the Abbott ARCHITECTci8200/ci16200 analysers. Not all samples were analysed for all assays due to volume requirements or assay/instrument availability. Results with elevated interference indices and those deemed unsuitable after clinical evaluation were removed from the database. Reference intervals were partitioned based on the method of Harris and Boyd into three scenarios, combined gender, males and females and age and gender. We have performed a detailed reference interval study on a healthy Australian population considering the effects of sex, age and body mass. These reference intervals may be adapted to other manufacturer's analytical methods using method transference.
Characteristic analysis and simulation for polysilicon comb micro-accelerometer
NASA Astrophysics Data System (ADS)
Liu, Fengli; Hao, Yongping
2008-10-01
High force update rate is a key factor for achieving high performance haptic rendering, which imposes a stringent real time requirement upon the execution environment of the haptic system. This requirement confines the haptic system to simplified environment for reducing the computation cost of haptic rendering algorithms. In this paper, we present a novel "hyper-threading" architecture consisting of several threads for haptic rendering. The high force update rate is achieved with relatively large computation time interval for each haptic loop. The proposed method was testified and proved to be effective with experiments on virtual wall prototype haptic system via Delta Haptic Device.
Botanical Evidence of the Modern History of Nisqually Glacier, Washington
Sigafoos, Robert S.; Hendricks, E.L.
1961-01-01
A knowledge of the areas once occupied by mountain glaciers reveals at least part of the past behavior of these glaciers. From this behavior, inferences of past climate can be drawn. The maximum advance of Nisqually Glacier in the last thousand years was located, and retreat from this point is believed to have started about 1840. The maximum downvalley position of the glacier is marked by either a prominent moraine or by a line of difference between stands of trees of strikingly different size and significantly different age. The thousand-year age of the forest beyond the moraine or line between abutting stands represents the minimum time since the surface was glaciated. This age is based on the age of the oldest trees, plus an estimated interval required for the formation of humus, plus evidence of an ancient fire, plus an interval of deposition of pyroclastics. The estimate of the date when Nisqually Glacier began to retreat from its maximum advance is based upon the ages of the oldest trees plus an interval of 5 years estimated as the time required for the establishment of trees on stable moraines. This interval was derived from a study of the ages of trees growing at locations of known past positions of the glacier. Reconnaissance studies were made on moraines formed by Emmons and Tahoma Glaciers. Preliminary analyses of these data suggest that Emmons Glacier started to recede from its maximum advance in about 1745. Two other upvalley moraines mark positions from which recession started about 1849 and 1896. Ages of trees near Tahoma Glacier indicate that it started to recede from its position of maximum advance in about 1635. About 1835 Tahoma Glacier started to recede again from another moraine formed by a readvance that ter minated near the 1635 position.
Glickman, Seth W; Lytle, Barbara L; Ou, Fang-Shu; Mears, Greg; O'Brien, Sean; Cairns, Charles B; Garvey, J Lee; Bohle, David J; Peterson, Eric D; Jollis, James G; Granger, Christopher B
2011-07-01
The ability to rapidly identify patients with ST-segment elevation-myocardial infarction (STEMI) at hospitals without percutaneous coronary intervention (PCI) and transfer them to hospitals with PCI capability is critical to STEMI regionalization efforts. Our objective was to assess the association of prehospital, emergency department (ED), and hospital processes of care implemented as part of a statewide STEMI regionalization program with door-in-door-out times at non-PCI hospitals. Door-in-door-out times for 436 STEMI patients at 55 non-PCI hospitals were determined before (July 2005 to September 2005) and after (January 2007 to March 2007) a year-long implementation of standardized protocols as part of a statewide regionalization program (Reperfusion of Acute Myocardial Infarction in North Carolina Emergency Departments, RACE). The association of 8 system care processes (encompassing emergency medical services [EMS], ED, and hospital settings) with door-in-door-out times was determined using multivariable linear regression. Median door-in-door-out times improved significantly with the intervention (before: 97.0 minutes, interquartile range, 56.0 to 160.0 minutes; after: 58.0 minutes, interquartile range, 35.0 to 90.0 minutes; P<0.0001). Hospital, ED, and EMS care processes were each independently associated with shorter door-in-door-out times (-17.7 [95% confidence interval, -27.5 to -7.9]; -10.1 [95% confidence interval, -19.0 to -1.1], and -7.3 [95% confidence interval, -13.0 to -1.5] minutes for each additional hospital, ED, and EMS process, respectively). Combined, adoption of EMS processes was associated with the shortest median treatment times (44 versus 138 minutes for hospitals that adopted all EMS processes versus none). Prehospital, ED, and hospital processes of care were independently associated with shorter door-in-door-out times for STEMI patients requiring transfer. Adoption of several EMS processes was associated with the largest reduction in treatment times. These findings highlight the need for an integrated, system-based approach to improving STEMI care.
Time perception, pacing and exercise intensity: maximal exercise distorts the perception of time.
Edwards, A M; McCormick, A
2017-10-15
Currently there are no data examining the impact of exercise on the perception of time, which is surprising as optimal competitive performance is dependent on accurate pacing using knowledge of time elapsed. With institutional ethics approval, 12 recreationally active adult participants (f=7, m=5) undertook both 30s Wingate cycles and 20min (1200s) rowing ergometer bouts as short and long duration self-paced exercise trials, in each of three conditions on separate occasions: 1) light exertion: RPE 11, 2) heavy exertion: RPE 15, 3) maximal exertion: RPE 20. Participants were unaware of exercise duration and were required to verbally indicate when they perceived (subjective time) 1) 25%, 2) 50%, 3) 75% and 4) 100% of each bout's measured (chronological) time had elapsed. In response to the Wingate task, there was no difference between durations of subjective time at the 25%, nor at the 50% interval. However, at the 75% and 100% intervals, the estimate for the RPE 20 condition was shortest (P<0.01). In response to rowing, there were no differences at the 25% interval, but there was some evidence that the RPE 20 condition was perceived shorter at 50%. At 75% and 100%, the RPE 20 condition was perceived to be shorter than both RPE 15 (P=0.04) and RPE 11 (P=0.008) conditions. This study is the first to empirically demonstrate that exercise intensity distorts time perception, particularly during maximal exercise. Consequently external feedback of chronological time may be an important factor for athletes undertaking maximal effort tasks or competitions. Copyright © 2017 Elsevier Inc. All rights reserved.
Azunre, P.
2016-09-21
Here in this paper, two novel techniques for bounding the solutions of parametric weakly coupled second-order semilinear parabolic partial differential equations are developed. The first provides a theorem to construct interval bounds, while the second provides a theorem to construct lower bounds convex and upper bounds concave in the parameter. The convex/concave bounds can be significantly tighter than the interval bounds because of the wrapping effect suffered by interval analysis in dynamical systems. Both types of bounds are computationally cheap to construct, requiring solving auxiliary systems twice and four times larger than the original system, respectively. An illustrative numerical examplemore » of bound construction and use for deterministic global optimization within a simple serial branch-and-bound algorithm, implemented numerically using interval arithmetic and a generalization of McCormick's relaxation technique, is presented. Finally, problems within the important class of reaction-diffusion systems may be optimized with these tools.« less
Cure rate model with interval censored data.
Kim, Yang-Jin; Jhun, Myoungshic
2008-01-15
In cancer trials, a significant fraction of patients can be cured, that is, the disease is completely eliminated, so that it never recurs. In general, treatments are developed to both increase the patients' chances of being cured and prolong the survival time among non-cured patients. A cure rate model represents a combination of cure fraction and survival model, and can be applied to many clinical studies over several types of cancer. In this article, the cure rate model is considered in the interval censored data composed of two time points, which include the event time of interest. Interval censored data commonly occur in the studies of diseases that often progress without symptoms, requiring clinical evaluation for detection (Encyclopedia of Biostatistics. Wiley: New York, 1998; 2090-2095). In our study, an approximate likelihood approach suggested by Goetghebeur and Ryan (Biometrics 2000; 56:1139-1144) is used to derive the likelihood in interval censored data. In addition, a frailty model is introduced to characterize the association between the cure fraction and survival model. In particular, the positive association between the cure fraction and the survival time is incorporated by imposing a common normal frailty effect. The EM algorithm is used to estimate parameters and a multiple imputation based on the profile likelihood is adopted for variance estimation. The approach is applied to the smoking cessation study in which the event of interest is a smoking relapse and several covariates including an intensive care treatment are evaluated to be effective for both the occurrence of relapse and the non-smoking duration. Copyright (c) 2007 John Wiley & Sons, Ltd.
Tosun, Tuğçe; Gür, Ezgi; Balcı, Fuat
2016-01-01
Animals can shape their timed behaviors based on experienced probabilistic relations in a nearly optimal fashion. On the other hand, it is not clear if they adopt these timed decisions by making computations based on previously learnt task parameters (time intervals, locations, and probabilities) or if they gradually develop their decisions based on trial and error. To address this question, we tested mice in the timed-switching task, which required them to anticipate when (after a short or long delay) and at which of the two delay locations a reward would be presented. The probability of short trials differed between test groups in two experiments. Critically, we first trained mice on relevant task parameters by signaling the active trial with a discriminative stimulus and delivered the corresponding reward after the associated delay without any response requirement (without inducing switching behavior). During the test phase, both options were presented simultaneously to characterize the emergence and temporal characteristics of the switching behavior. Mice exhibited timed-switching behavior starting from the first few test trials, and their performance remained stable throughout testing in the majority of the conditions. Furthermore, as the probability of the short trial increased, mice waited longer before switching from the short to long location (experiment 1). These behavioral adjustments were in directions predicted by reward maximization. These results suggest that rather than gradually adjusting their time-dependent choice behavior, mice abruptly adopted temporal decision strategies by directly integrating their previous knowledge of task parameters into their timed behavior, supporting the model-based representational account of temporal risk assessment. PMID:26733674
Brenner, Laurie A; Shih, Vivian H; Colich, Natalie L; Sugar, Catherine A; Bearden, Carrie E; Dapretto, Mirella
2015-02-01
Impaired temporal processing has historically been viewed as a hallmark feature of attention deficit hyperactivity disorder. Recent evidence suggests temporal processing deficits may also be characteristic of autism spectrum disorder (ASD). However, little is known about the factors that impact temporal processing in children with ASD. The purpose of this study was to assess the effects of co-morbid attention problems, working memory (WM), age, and their interactions, on time reproduction in youth with and without ASD. Twenty-seven high-functioning individuals with ASD and 25 demographically comparable typically developing individuals (ages 9-17; 85% male) were assessed on measures of time reproduction, auditory WM, and inattention/hyperactivity. The time reproduction task required depression of a computer key to mimic interval durations of 4, 8, 12, 16, or 20 sec. Mixed effects regression analyses were used to model accuracy and variability of time reproduction as functions of diagnostic group, interval duration, age, WM, and inattention/hyperactivity. A significant group by age interaction was detected for accuracy, with the deficit in the ASD group being greater in younger children. There was a significant group by WM interaction for consistency, with the effects of poor WM on performance consistency being more pronounced in youth with ASD. All participants tended to underestimate longer interval durations and to be less consistent for shorter interval durations; these effects appeared more pronounced in those who were younger or who had poorer WM performance. Inattention/hyperactivity symptoms in the ASD group were not related to either accuracy or consistency. This study highlights the potential value of temporal processing as an intermediate trait of relevance to multiple neurodevelopmental disorders. © 2014 International Society for Autism Research, Wiley Periodicals, Inc.
Time-response shaping using output to input saturation transformation
NASA Astrophysics Data System (ADS)
Chambon, E.; Burlion, L.; Apkarian, P.
2018-03-01
For linear systems, the control law design is often performed so that the resulting closed loop meets specific frequency-domain requirements. However, in many cases, it may be observed that the obtained controller does not enforce time-domain requirements amongst which the objective of keeping a scalar output variable in a given interval. In this article, a transformation is proposed to convert prescribed bounds on an output variable into time-varying saturations on the synthesised linear scalar control law. This transformation uses some well-chosen time-varying coefficients so that the resulting time-varying saturation bounds do not overlap in the presence of disturbances. Using an anti-windup approach, it is obtained that the origin of the resulting closed loop is globally asymptotically stable and that the constrained output variable satisfies the time-domain constraints in the presence of an unknown finite-energy-bounded disturbance. An application to a linear ball and beam model is presented.
The Role of Patients and Providers in the Timing of Follow-up Visits
Welch, H Gilbert; Chapko, Michael K; James, Kenneth E; Schwartz, Lisa M; Woloshin, Steven
1999-01-01
OBJECTIVE Although the decision about how frequently to see outpatients has a direct impact on a provider’s workload and may impact health care costs, revisit intervals have rarely been a topic of investigation. To begin to understand what factors are correlated with this decision, we examined baseline data from a Department of Veterans Affairs (VA) Cooperative Study designed to evaluate telephone care. DESIGN Observational study based on extensive patient data collected during enrollment into the randomized trial. Providers were required to recommend a revisit interval (e.g., “return visit in 3 months”) for each patient before randomization, under the assumption that the patient would be receiving clinic visits as usual. POPULATON/SETTING Five hundred seventy-one patients over age 55 cared for by one of the 30 providers working in three VA general medical clinics. Patients for whom immediate follow-up (≤2 weeks) was recommended were excluded. MEASUREMENTS Mean revisit interval was adjusted for patient factors using a regression model that accounted for patients being nested within providers and providers being nested within sites. Four patient-level variable blocks (illness burden–patient, travel time, illness burden–physician, and prior utilization) were sequentially entered into a linear model to determine their role in explaining the variance in revisit intervals. Physician identity was also entered after four blocks. MAIN RESULTS Recommended revisit intervals ranged from 1 month to over 1 year with the most common recommended intervals being 2, 3, or 6 months. About 10% of the variance in revisit interval was explained by illness measures independent of provider (e.g., general health perception) and travel time. Adding other illness measures (e.g., diagnoses, medications) and prior utilization (e.g., clinic visits) doubled the variance explained (R2= .21). Finally, the identification of individual provider doubled the explained variance again (R2= .45). After adjusting for patient factors, the average revisit interval for individual providers ranged from 8 to 26 weeks (8 to 19 weeks when restricted to the 16 staff physicians). There were also substantial differences across the three sites (adjusted means: 14, 17, and 11 weeks). CONCLUSIONS Even after adjusting for a detailed array of patient-level data, primary care providers have different practice styles regarding the timing of return visits. These may, in turn, reflect the local “culture” in which they practice. How many patients providers are able to care for may be determined by the providers’ inclinations toward the timing of follow-up visits. PMID:10203634
Martin, Thomas J.; Grigg, Amanda; Kim, Susy A.; Ririe, Douglas G.; Eisenach, James C.
2014-01-01
Background The 5 choice serial reaction time task (5CSRTT) is commonly used to assess attention in rodents. We sought to develop a variant of the 5CSRTT that would speed training to objective success criteria, and to test whether this variant could determine attention capability in each subject. New Method Fisher 344 rats were trained to perform a variant of the 5CSRTT in which the duration of visual cue presentation (cue duration) was titrated between trials based upon performance. The cue duration was decreased when the subject made a correct response, or increased with incorrect responses or omissions. Additionally, test day challenges were provided consisting of lengthening the intertrial interval and inclusion of a visual distracting stimulus. Results Rats readily titrated the cue duration to less than 1 sec in 25 training sessions or less (mean ± SEM, 22.9 ± 0.7), and the median cue duration (MCD) was calculated as a measure of attention threshold. Increasing the intertrial interval increased premature responses, decreased the number of trials completed, and increased the MCD. Decreasing the intertrial interval and time allotted for consuming the food reward demonstrated that a minimum of 3.5 sec is required for rats to consume two food pellets and successfully attend to the next trial. Visual distraction in the form of a 3 Hz flashing light increased the MCD and both premature and time out responses. Comparison with existing method The titration variant of the 5CSRTT is a useful method that dynamically measures attention threshold across a wide range of subject performance, and significantly decreases the time required for training. Task challenges produce similar effects in the titration method as reported for the classical procedure. Conclusions The titration 5CSRTT method is an efficient training procedure for assessing attention and can be utilized to assess the limit in performance ability across subjects and various schedule manipulations. PMID:25528113
NASA Astrophysics Data System (ADS)
Niakan, F.; Vahdani, B.; Mohammadi, M.
2015-12-01
This article proposes a multi-objective mixed-integer model to optimize the location of hubs within a hub network design problem under uncertainty. The considered objectives include minimizing the maximum accumulated travel time, minimizing the total costs including transportation, fuel consumption and greenhouse emissions costs, and finally maximizing the minimum service reliability. In the proposed model, it is assumed that for connecting two nodes, there are several types of arc in which their capacity, transportation mode, travel time, and transportation and construction costs are different. Moreover, in this model, determining the capacity of the hubs is part of the decision-making procedure and balancing requirements are imposed on the network. To solve the model, a hybrid solution approach is utilized based on inexact programming, interval-valued fuzzy programming and rough interval programming. Furthermore, a hybrid multi-objective metaheuristic algorithm, namely multi-objective invasive weed optimization (MOIWO), is developed for the given problem. Finally, various computational experiments are carried out to assess the proposed model and solution approaches.
Oprisan, Sorinel A.; Buhusi, Catalin V.
2011-01-01
In most species, the capability of perceiving and using the passage of time in the seconds-to-minutes range (interval timing) is not only accurate but also scalar: errors in time estimation are linearly related to the estimated duration. The ubiquity of scalar timing extends over behavioral, lesion, and pharmacological manipulations. For example, in mammals, dopaminergic drugs induce an immediate, scalar change in the perceived time (clock pattern), whereas cholinergic drugs induce a gradual, scalar change in perceived time (memory pattern). How do these properties emerge from unreliable, noisy neurons firing in the milliseconds range? Neurobiological information relative to the brain circuits involved in interval timing provide support for an striatal beat frequency (SBF) model, in which time is coded by the coincidental activation of striatal spiny neurons by cortical neural oscillators. While biologically plausible, the impracticality of perfect oscillators, or their lack thereof, questions this mechanism in a brain with noisy neurons. We explored the computational mechanisms required for the clock and memory patterns in an SBF model with biophysically realistic and noisy Morris–Lecar neurons (SBF–ML). Under the assumption that dopaminergic drugs modulate the firing frequency of cortical oscillators, and that cholinergic drugs modulate the memory representation of the criterion time, we show that our SBF–ML model can reproduce the pharmacological clock and memory patterns observed in the literature. Numerical results also indicate that parameter variability (noise) – which is ubiquitous in the form of small fluctuations in the intrinsic frequencies of neural oscillators within and between trials, and in the errors in recording/retrieving stored information related to criterion time – seems to be critical for the time-scale invariance of the clock and memory patterns. PMID:21977014
Convergence Time towards Periodic Orbits in Discrete Dynamical Systems
San Martín, Jesús; Porter, Mason A.
2014-01-01
We investigate the convergence towards periodic orbits in discrete dynamical systems. We examine the probability that a randomly chosen point converges to a particular neighborhood of a periodic orbit in a fixed number of iterations, and we use linearized equations to examine the evolution near that neighborhood. The underlying idea is that points of stable periodic orbit are associated with intervals. We state and prove a theorem that details what regions of phase space are mapped into these intervals (once they are known) and how many iterations are required to get there. We also construct algorithms that allow our theoretical results to be implemented successfully in practice. PMID:24736594
Riyapan, Sattha; Lubin, Jeffrey
2016-03-01
We attempted to determine the effect of prearrival instructions that included the specific location of automated external defibrillators (AEDs) in a public venue on the time to defibrillation in a simulated cardiac arrest scenario using untrained bystanders. The study was a randomized controlled trial at an urban shopping mall. Participants were asked to retrieve an AED and come back to defibrillate a mannequin. Only the experimental group received the location of the AED. We measured the percentage of shocks that were delivered in less than 3 minutes from the start of the scenario and also recorded several other time intervals. Thirty-nine participants completed the study, with 20 participants in the experimental group. The median time to defibrillation in the experimental group was 2.6 minutes (interquartile range, 2.4-2.8) which was significantly less than the control group's median time of 5.9 minutes (interquartile range, 4.38-7.65). Ninety percent (95% confidence interval, 68.3%-98.8%) of the participants in the experimental group defibrillated within 3 minutes, which was significantly different from the control group (10.5%; 95% confidence interval, 1.3%-33.1%). In this study, a prearrival protocol providing participants with the location of the nearest AED in a public building resulted in a significant decrease in the time required to deliver a simulated shock. Further investigations in various types of public settings are needed to confirm the results. Copyright © 2015 Elsevier Inc. All rights reserved.
The stability of M(max) and H (max) amplitude over time.
McNulty, Penelope A; Shiner, Christine T; Thayaparan, Ganesha K; Burke, David
2012-05-01
The stability of the maximal muscle response (M(max)) is critical to H reflex methodology. It has previously been reported that the amplitude of M(max) declines over time. If reproducible, this finding would have implications for all experimental studies that normalise the output of the motoneurone pool against the M wave. We investigated the effect of time on changes in M(max) and the maximal H reflex (H(max)) evoked at 4-s intervals over 60 min. To identify an influence of homosynaptic depression, we extended the interstimulus interval to 10 s and the time to 100 min. Two recording montages over soleus were used to ensure that interelectrode distance was not a critical factor. The soleus M(max) and H reflex were evoked by stimulation of the tibial nerve in the popliteal fossa in 7 subjects who sat with the knee flexed to 30° and the ankle plantar flexed by ~30°. We found no change in the pooled data for M(max), H(max), a reflex 50% of maximal, or the current required to produce it. However, one subject had a statistically significant increase in M(max) and a concurrent decrease in H(max) regardless of the interstimulus interval. On average, there was no change in the H(max)/M(max) ratio over time. While both M(max) and H(max) may change in response to many factors, these results suggest that, typically, time is not one of them.
Greg C. Liknes; Christopher W. Woodall; Charles H. Perry
2009-01-01
Climate information frequently is included in geospatial modeling efforts to improve the predictive capability of other data sources. The selection of an appropriate climate data source requires consideration given the number of choices available. With regard to climate data, there are a variety of parameters (e.g., temperature, humidity, precipitation), time intervals...
How to make a wind-movement recorder from any spare drum-type recorder
Irvin C. Reigner
1964-01-01
The automatic recording of wind movement is sometimes essential to experiments in forestry and watershed-management research. Wind-movement data are often obtained by periodic reading of the anemometer dial, but occasionally data are required for variable intervals and at times when observations cannot be made easily. Instruments designed to record wind movement are...
USDA-ARS?s Scientific Manuscript database
Direct normal irradiance (DNI) is required to evaluate performance of concentrating solar energy systems. The objective of this paper is to analyze the effect of time interval (e.g. year, month, hour) on the accuracy of three different DNI models. The DNI data were measured at three different labora...
SPA- STATISTICAL PACKAGE FOR TIME AND FREQUENCY DOMAIN ANALYSIS
NASA Technical Reports Server (NTRS)
Brownlow, J. D.
1994-01-01
The need for statistical analysis often arises when data is in the form of a time series. This type of data is usually a collection of numerical observations made at specified time intervals. Two kinds of analysis may be performed on the data. First, the time series may be treated as a set of independent observations using a time domain analysis to derive the usual statistical properties including the mean, variance, and distribution form. Secondly, the order and time intervals of the observations may be used in a frequency domain analysis to examine the time series for periodicities. In almost all practical applications, the collected data is actually a mixture of the desired signal and a noise signal which is collected over a finite time period with a finite precision. Therefore, any statistical calculations and analyses are actually estimates. The Spectrum Analysis (SPA) program was developed to perform a wide range of statistical estimation functions. SPA can provide the data analyst with a rigorous tool for performing time and frequency domain studies. In a time domain statistical analysis the SPA program will compute the mean variance, standard deviation, mean square, and root mean square. It also lists the data maximum, data minimum, and the number of observations included in the sample. In addition, a histogram of the time domain data is generated, a normal curve is fit to the histogram, and a goodness-of-fit test is performed. These time domain calculations may be performed on both raw and filtered data. For a frequency domain statistical analysis the SPA program computes the power spectrum, cross spectrum, coherence, phase angle, amplitude ratio, and transfer function. The estimates of the frequency domain parameters may be smoothed with the use of Hann-Tukey, Hamming, Barlett, or moving average windows. Various digital filters are available to isolate data frequency components. Frequency components with periods longer than the data collection interval are removed by least-squares detrending. As many as ten channels of data may be analyzed at one time. Both tabular and plotted output may be generated by the SPA program. This program is written in FORTRAN IV and has been implemented on a CDC 6000 series computer with a central memory requirement of approximately 142K (octal) of 60 bit words. This core requirement can be reduced by segmentation of the program. The SPA program was developed in 1978.
Evaluating Protocol Lifecycle Time Intervals in HIV/AIDS Clinical Trials
Schouten, Jeffrey T.; Dixon, Dennis; Varghese, Suresh; Cope, Marie T.; Marci, Joe; Kagan, Jonathan M.
2014-01-01
Background Identifying efficacious interventions for the prevention and treatment of human diseases depends on the efficient development and implementation of controlled clinical trials. Essential to reducing the time and burden of completing the clinical trial lifecycle is determining which aspects take the longest, delay other stages, and may lead to better resource utilization without diminishing scientific quality, safety, or the protection of human subjects. Purpose In this study we modeled time-to-event data to explore relationships between clinical trial protocol development and implementation times, as well as identify potential correlates of prolonged development and implementation. Methods We obtained time interval and participant accrual data from 111 interventional clinical trials initiated between 2006 and 2011 by NIH’s HIV/AIDS Clinical Trials Networks. We determined the time (in days) required to complete defined phases of clinical trial protocol development and implementation. Kaplan-Meier estimates were used to assess the rates at which protocols reached specified terminal events, stratified by study purpose (therapeutic, prevention) and phase group (pilot/phase I, phase II, and phase III/ IV). We also examined several potential correlates to prolonged development and implementation intervals. Results Even though phase grouping did not determine development or implementation times of either therapeutic or prevention studies, overall we observed wide variation in protocol development times. Moreover, we detected a trend toward phase III/IV therapeutic protocols exhibiting longer developmental (median 2 ½ years) and implementation times (>3years). We also found that protocols exceeding the median number of days for completing the development interval had significantly longer implementation. Limitations The use of a relatively small set of protocols may have limited our ability to detect differences across phase groupings. Some timing effects present for a specific study phase may have been masked by combining protocols into phase groupings. Presence of informative censoring, such as withdrawal of some protocols from development if they began showing signs of lost interest among investigators, complicates interpretation of Kaplan-Meier estimates. Because this study constitutes a retrospective examination over an extended period of time, it does not allow for the precise identification of relative factors impacting timing. Conclusions Delays not only increase the time and cost to complete clinical trials, but they also diminish their usefulness by failing to answer research questions in time. We believe that research analyzing the time spent traversing defined intervals across the clinical trial protocol development and implementation continuum can stimulate business process analyses and reengineering efforts that could lead to reductions in the time from clinical trial concept to results, thereby accelerating progress in clinical research. PMID:24980279
Timescale- and Sensory Modality-Dependency of the Central Tendency of Time Perception.
Murai, Yuki; Yotsumoto, Yuko
2016-01-01
When individuals are asked to reproduce intervals of stimuli that are intermixedly presented at various times, longer intervals are often underestimated and shorter intervals overestimated. This phenomenon may be attributed to the central tendency of time perception, and suggests that our brain optimally encodes a stimulus interval based on current stimulus input and prior knowledge of the distribution of stimulus intervals. Two distinct systems are thought to be recruited in the perception of sub- and supra-second intervals. Sub-second timing is subject to local sensory processing, whereas supra-second timing depends on more centralized mechanisms. To clarify the factors that influence time perception, the present study investigated how both sensory modality and timescale affect the central tendency. In Experiment 1, participants were asked to reproduce sub- or supra-second intervals, defined by visual or auditory stimuli. In the sub-second range, the magnitude of the central tendency was significantly larger for visual intervals compared to auditory intervals, while visual and auditory intervals exhibited a correlated and comparable central tendency in the supra-second range. In Experiment 2, the ability to discriminate sub-second intervals in the reproduction task was controlled across modalities by using an interval discrimination task. Even when the ability to discriminate intervals was controlled, visual intervals exhibited a larger central tendency than auditory intervals in the sub-second range. In addition, the magnitude of the central tendency for visual and auditory sub-second intervals was significantly correlated. These results suggest that a common modality-independent mechanism is responsible for the supra-second central tendency, and that both the modality-dependent and modality-independent components of the timing system contribute to the central tendency in the sub-second range.
Real-time hydraulic interval state estimation for water transport networks: a case study
NASA Astrophysics Data System (ADS)
Vrachimis, Stelios G.; Eliades, Demetrios G.; Polycarpou, Marios M.
2018-03-01
Hydraulic state estimation in water distribution networks is the task of estimating water flows and pressures in the pipes and nodes of the network based on some sensor measurements. This requires a model of the network as well as knowledge of demand outflow and tank water levels. Due to modeling and measurement uncertainty, standard state estimation may result in inaccurate hydraulic estimates without any measure of the estimation error. This paper describes a methodology for generating hydraulic state bounding estimates based on interval bounds on the parametric and measurement uncertainties. The estimation error bounds provided by this method can be applied to determine the existence of unaccounted-for water in water distribution networks. As a case study, the method is applied to a modified transport network in Cyprus, using actual data in real time.
Sampling effects on the identification of roadkill hotspots: Implications for survey design.
Santos, Sara M; Marques, J Tiago; Lourenço, André; Medinas, Denis; Barbosa, A Márcia; Beja, Pedro; Mira, António
2015-10-01
Although locating wildlife roadkill hotspots is essential to mitigate road impacts, the influence of study design on hotspot identification remains uncertain. We evaluated how sampling frequency affects the accuracy of hotspot identification, using a dataset of vertebrate roadkills (n = 4427) recorded over a year of daily surveys along 37 km of roads. "True" hotspots were identified using this baseline dataset, as the 500-m segments where the number of road-killed vertebrates exceeded the upper 95% confidence limit of the mean, assuming a Poisson distribution of road-kills per segment. "Estimated" hotspots were identified likewise, using datasets representing progressively lower sampling frequencies, which were produced by extracting data from the baseline dataset at appropriate time intervals (1-30 days). Overall, 24.3% of segments were "true" hotspots, concentrating 40.4% of roadkills. For different groups, "true" hotspots accounted from 6.8% (bats) to 29.7% (small birds) of road segments, concentrating from <40% (frogs and toads, snakes) to >60% (lizards, lagomorphs, carnivores) of roadkills. Spatial congruence between "true" and "estimated" hotspots declined rapidly with increasing time interval between surveys, due primarily to increasing false negatives (i.e., missing "true" hotspots). There were also false positives (i.e., wrong "estimated" hotspots), particularly at low sampling frequencies. Spatial accuracy decay with increasing time interval between surveys was higher for smaller-bodied (amphibians, reptiles, small birds, small mammals) than for larger-bodied species (birds of prey, hedgehogs, lagomorphs, carnivores). Results suggest that widely used surveys at weekly or longer intervals may produce poor estimates of roadkill hotspots, particularly for small-bodied species. Surveying daily or at two-day intervals may be required to achieve high accuracy in hotspot identification for multiple species. Copyright © 2015 Elsevier Ltd. All rights reserved.
Novel method for high-throughput phenotyping of sleep in mice.
Pack, Allan I; Galante, Raymond J; Maislin, Greg; Cater, Jacqueline; Metaxas, Dimitris; Lu, Shan; Zhang, Lin; Von Smith, Randy; Kay, Timothy; Lian, Jie; Svenson, Karen; Peters, Luanne L
2007-01-17
Assessment of sleep in mice currently requires initial implantation of chronic electrodes for assessment of electroencephalogram (EEG) and electromyogram (EMG) followed by time to recover from surgery. Hence, it is not ideal for high-throughput screening. To address this deficiency, a method of assessment of sleep and wakefulness in mice has been developed based on assessment of activity/inactivity either by digital video analysis or by breaking infrared beams in the mouse cage. It is based on the algorithm that any episode of continuous inactivity of > or =40 s is predicted to be sleep. The method gives excellent agreement in C57BL/6J male mice with simultaneous assessment of sleep by EEG/EMG recording. The average agreement over 8,640 10-s epochs in 24 h is 92% (n = 7 mice) with agreement in individual mice being 88-94%. Average EEG/EMG determined sleep per 2-h interval across the day was 59.4 min. The estimated mean difference (bias) per 2-h interval between inactivity-defined sleep and EEG/EMG-defined sleep was only 1.0 min (95% confidence interval for mean bias -0.06 to +2.6 min). The standard deviation of differences (precision) was 7.5 min per 2-h interval with 95% limits of agreement ranging from -13.7 to +15.7 min. Although bias significantly varied by time of day (P = 0.0007), the magnitude of time-of-day differences was not large (average bias during lights on and lights off was +5.0 and -3.0 min per 2-h interval, respectively). This method has applications in chemical mutagenesis and for studies of molecular changes in brain with sleep/wakefulness.
Moderate Recovery Unnecessary to Sustain High Stroke Volume during Interval Training. A Brief Report
Stanley, Jamie; Buchheit, Martin
2014-01-01
It has been suggested that the time spent at a high stroke volume (SV) is important for improving maximal cardiac function. The aim of this study was to examine the effect of recovery intensity on cardiovascular parameters during a typical high-intensity interval training (HIIT) session in fourteen well-trained cyclists. Oxygen consumption (VO2), heart rate (HR), SV, cardiac output (Qc), and oxygenation of vastus lateralis (TSI) were measured during a HIIT (3×3-min work period, 2 min of recovery) session on two occasions. VO2, HR and Qc were largely higher during moderate-intensity (60%) compared with low-intensity (30%) (VO2, effect size; ES = +2.6; HR, ES = +2.8; Qc, ES = +2.2) and passive (HR, ES = +2.2; Qc, ES = +1.7) recovery. By contrast, there was no clear difference in SV between the three recovery conditions, with the SV during the two active recovery periods not being substantially different than during exercise (60%, ES = −0.1; 30%, ES = −0.2). To conclude, moderate-intensity recovery may not be required to maintain a high SV during HIIT. Key points Moderate-intensity recovery periods may not be necessary to maintain high stroke volume during the exercise intervals of HIIT. Stroke volume did not surpass the levels attained during the exercise intervals during the recovery periods of HIIT. The practical implication of these finding is that reducing the intensity of the recovery period during a HIIT protocol may prolong the time to exhaustion, potentially allowing completion of additional high-intensity intervals increasing the time accumulated at maximal cardiac output. PMID:24790495
High resolution data acquisition
Thornton, G.W.; Fuller, K.R.
1993-04-06
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
High resolution data acquisition
Thornton, Glenn W.; Fuller, Kenneth R.
1993-01-01
A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.
Zhang, Fang; Wagner, Anita K; Soumerai, Stephen B; Ross-Degnan, Dennis
2009-02-01
Interrupted time series (ITS) is a strong quasi-experimental research design, which is increasingly applied to estimate the effects of health services and policy interventions. We describe and illustrate two methods for estimating confidence intervals (CIs) around absolute and relative changes in outcomes calculated from segmented regression parameter estimates. We used multivariate delta and bootstrapping methods (BMs) to construct CIs around relative changes in level and trend, and around absolute changes in outcome based on segmented linear regression analyses of time series data corrected for autocorrelated errors. Using previously published time series data, we estimated CIs around the effect of prescription alerts for interacting medications with warfarin on the rate of prescriptions per 10,000 warfarin users per month. Both the multivariate delta method (MDM) and the BM produced similar results. BM is preferred for calculating CIs of relative changes in outcomes of time series studies, because it does not require large sample sizes when parameter estimates are obtained correctly from the model. Caution is needed when sample size is small.
Lawhern, Vernon; Hairston, W David; Robbins, Kay
2013-01-01
Recent advances in sensor and recording technology have allowed scientists to acquire very large time-series datasets. Researchers often analyze these datasets in the context of events, which are intervals of time where the properties of the signal change relative to a baseline signal. We have developed DETECT, a MATLAB toolbox for detecting event time intervals in long, multi-channel time series. Our primary goal is to produce a toolbox that is simple for researchers to use, allowing them to quickly train a model on multiple classes of events, assess the accuracy of the model, and determine how closely the results agree with their own manual identification of events without requiring extensive programming knowledge or machine learning experience. As an illustration, we discuss application of the DETECT toolbox for detecting signal artifacts found in continuous multi-channel EEG recordings and show the functionality of the tools found in the toolbox. We also discuss the application of DETECT for identifying irregular heartbeat waveforms found in electrocardiogram (ECG) data as an additional illustration.
Lawhern, Vernon; Hairston, W. David; Robbins, Kay
2013-01-01
Recent advances in sensor and recording technology have allowed scientists to acquire very large time-series datasets. Researchers often analyze these datasets in the context of events, which are intervals of time where the properties of the signal change relative to a baseline signal. We have developed DETECT, a MATLAB toolbox for detecting event time intervals in long, multi-channel time series. Our primary goal is to produce a toolbox that is simple for researchers to use, allowing them to quickly train a model on multiple classes of events, assess the accuracy of the model, and determine how closely the results agree with their own manual identification of events without requiring extensive programming knowledge or machine learning experience. As an illustration, we discuss application of the DETECT toolbox for detecting signal artifacts found in continuous multi-channel EEG recordings and show the functionality of the tools found in the toolbox. We also discuss the application of DETECT for identifying irregular heartbeat waveforms found in electrocardiogram (ECG) data as an additional illustration. PMID:23638169
Inui, N; Ichihara, T
2001-10-01
To examine the relation between timing and force control during finger taping sequences by both pianists and nonpianists, participants tapped a force plate connected to strain gauges. A series of finger tapping tasks consisted of 16 combinations of pace (intertap interval: 180, 200, 400, or 800 ms) and peak force (50, 100, 200, or 400 g). Analysis showed that, although movement timing was independent of force control under low or medium pace conditions, there were strong interactions between the 2 parameters under high pace conditions. The results indicate that participants adapted the movement by switching from separately controlling these parameters in the slow and moderate movement to coupling them in the fast movement. While variations in the intertap interval affected force production by nonpianists, they had little effect for pianists. The ratios of time-to-peak force to press duration increased linearly in pianists but varied irregularly in nonpianists, as the required force decreased. Thus, pianists regulate peak force by timing control of peak force to press duration, suggesting that training affects the relationship between the 2 parameters.
[Waiting time for the first colposcopic examination in women with abnormal Papanicolaou test].
Nascimento, Maria Isabel do; Rabelo, Irene Machado Moraes Alvarenga; Cardoso, Fabrício Seabra Polidoro; Musse, Ricardo Neif Vieira
2015-08-01
To evaluate the waiting times before obtaining the first colposcopic examination for women with abnormal Papanicolaou smears. Retrospective cohort study conducted on patients who required a colposcopic examination to clarify an abnormal pap test, between 2002 January and 2008 August, in a metropolitan region of Brazil. The waiting times were defined as: Total Waiting Time (interval between the date of the pap test result and the date of the first colposcopic examination); Partial A Waiting Time (interval between the date of the pap test result and the date of referral); Partial B Waiting Time (interval between the date of referral and the date of the first colposcopic examination). Means, medians, relative and absolute frequencies were calculated. The Kruskal-Wallis test and Pearson's chi-square test were used to determine statistical significance. A total of 1,544 women with mean of age of 34 years (SD=12.6 years) were analyzed. Most of them had access to colposcopic examination within 30 days (65.8%) or 60 days (92.8%) from referral. Mean Total Waiting Time, Partial A Waiting Time, and Partial B Waiting Time were 94.5 days (SD=96.8 days), 67.8 days (SD=95.3 days) and 29.2 days (SD=35.1 days), respectively. A large part of the women studied had access to colposcopic examination within 60 days after referral, but Total waiting time was long. Measures to reduce the waiting time for obtaining the first colposcopic examination can help to improve the quality of care in the context of cervical cancer control in the region, and ought to be addressed at the phase between the date of the pap test results and the date of referral to the teaching hospital.
Scheinberg, Morton; Goldenberg, José; Feldman, Daniel P; Nóbrega, João Luiz
2008-08-01
We determined, in our surrounding environment, the proportion of patients being treated with infliximab who required a therapeutic scheme escalation (an infliximab dose increase surpassing the level of 3 mg/kg every 8 weeks and/or a decrease on the current between infusions' interval). This was a study of the retrospective analysis of data from the 41 rheumatoid arthritis (RA) patients receiving an infliximab therapy at the Albert Einstein Israelita Hospital, from January 2001 up to December 2005. A questionnaire was applied to these patients, assessing their clinical and laboratory data, adverse events, and individual information regarding the infliximab administration. Therapeutic dose information was available in 68% (28/41) of the RA patients, with 46% of these (13/28) receiving a dose increase, and 30% (8/27) experiencing a shortening of the between infusions' interval. The average final infliximab dose (4.21 mg/kg) was significantly greater than their average initial dose (3.29 mg/kg). The average time intervals between the initial and final infusions, though shortened, were not significantly different. A proportion of 73% (30/41) of these patients demonstrated improvement in at least one of the assessed clinical parameters, and 50% of these patients (15/30) experienced a dose increase, while 20% (6/30) experienced shortening of the between treatments' interval. A total of 20% (8/41) of the original patients experienced adverse events. Although infliximab is effective in the control of RA, dose adjustment and/or shortening of the between treatments' interval is frequently required.
Gurd, Brendon J; Patel, Jugal; Edgett, Brittany A; Scribbans, Trisha D; Quadrilatero, Joe; Fischer, Steven L
2018-05-28
Whole body sprint-interval training (WB-SIT) represents a mode of exercise training that is both time-efficient and does not require access to an exercise facility. The current study examined the feasibility of implementing a WB-SIT intervention in a workplace setting. A total of 747 employees from a large office building were invited to participate with 31 individuals being enrolled in the study. Anthropometrics, aerobic fitness, core and upper body strength, and lower body mobility were assessed before and after a 12-week exercise intervention consisting of 2-4 training sessions per week. Each training session required participants to complete 8, 20-second intervals (separated by 10 seconds of rest) of whole body exercise. Proportion of participation was 4.2% while the response rate was 35% (11/31 participants completed post training testing). In responders, compliance to prescribed training was 83±17%, and significant (p < 0.05) improvements were observed for aerobic fitness, push-up performance and lower body mobility. These results demonstrate the efficacy of WB-FIT for improving fitness and mobility in an office setting, but highlight the difficulties in achieving high rates of participation and response in this setting.
Modulation of human time processing by subthalamic deep brain stimulation.
Wojtecki, Lars; Elben, Saskia; Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons
2011-01-01
Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥ 130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥ 130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds.
Modulation of Human Time Processing by Subthalamic Deep Brain Stimulation
Timmermann, Lars; Reck, Christiane; Maarouf, Mohammad; Jörgens, Silke; Ploner, Markus; Südmeyer, Martin; Groiss, Stefan Jun; Sturm, Volker; Niedeggen, Michael; Schnitzler, Alfons
2011-01-01
Timing in the range of seconds referred to as interval timing is crucial for cognitive operations and conscious time processing. According to recent models of interval timing basal ganglia (BG) oscillatory loops are involved in time interval recognition. Parkinsońs disease (PD) is a typical disease of the basal ganglia that shows distortions in interval timing. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a powerful treatment of PD which modulates motor and cognitive functions depending on stimulation frequency by affecting subcortical-cortical oscillatory loops. Thus, for the understanding of BG-involvement in interval timing it is of interest whether STN-DBS can modulate timing in a frequency dependent manner by interference with oscillatory time recognition processes. We examined production and reproduction of 5 and 15 second intervals and millisecond timing in a double blind, randomised, within-subject repeated-measures design of 12 PD-patients applying no, 10-Hz- and ≥130-Hz-STN-DBS compared to healthy controls. We found under(re-)production of the 15-second interval and a significant enhancement of this under(re-)production by 10-Hz-stimulation compared to no stimulation, ≥130-Hz-STN-DBS and controls. Milliseconds timing was not affected. We provide first evidence for a frequency-specific modulatory effect of STN-DBS on interval timing. Our results corroborate the involvement of BG in general and of the STN in particular in the cognitive representation of time intervals in the range of multiple seconds. PMID:21931767
Janczyk, Markus; Berryhill, Marian E
2014-04-01
The retro-cue effect (RCE) describes superior working memory performance for validly cued stimulus locations long after encoding has ended. Importantly, this happens with delays beyond the range of iconic memory. In general, the RCE is a stable phenomenon that emerges under varied stimulus configurations and timing parameters. We investigated its susceptibility to dual-task interference to determine the attentional requirements at the time point of cue onset and encoding. In Experiment 1, we compared single- with dual-task conditions. In Experiment 2, we borrowed from the psychological refractory period paradigm and compared conditions with high and low (dual-) task overlap. The secondary task was always binary tone discrimination requiring a manual response. Across both experiments, an RCE was found, but it was diminished in magnitude in the critical dual-task conditions. A previous study did not find evidence that sustained attention is required in the interval between cue offset and test. Our results apparently contradict these findings and point to a critical time period around cue onset and briefly thereafter during which attention is required.
Berryhill, Marian E.
2014-01-01
The retro-cue effect (RCE) describes superior working memory performance for validly cued stimulus locations long after encoding has ended. Importantly, this happens with delays beyond the range of iconic memory. In general, the RCE is a stable phenomenon that emerges under varied stimulus configurations and timing parameters. We investigated its susceptibility to dual-task interference to determine the attentional requirements at the time point of cue onset and encoding. In Experiment 1, we compared single- with dual-task conditions. In Experiment 2, we borrowed from the psychological refractory period paradigm and compared conditions with high and low (dual-) task overlap. The secondary task was always binary tone discrimination requiring amanual response. Across both experiments, an RCE was found, but it was diminished in magnitude in the critical dual-task conditions. A previous study did not find evidence that sustained attention is required in the interval between cue offset and test. Our results apparently contradict these findings and point to a critical time period around cue onset and briefly thereafter during which attention is required. PMID:24452383
On reliable control system designs. Ph.D. Thesis; [actuators
NASA Technical Reports Server (NTRS)
Birdwell, J. D.
1978-01-01
A mathematical model for use in the design of reliable multivariable control systems is discussed with special emphasis on actuator failures and necessary actuator redundancy levels. The model consists of a linear time invariant discrete time dynamical system. Configuration changes in the system dynamics are governed by a Markov chain that includes transition probabilities from one configuration state to another. The performance index is a standard quadratic cost functional, over an infinite time interval. The actual system configuration can be deduced with a one step delay. The calculation of the optimal control law requires the solution of a set of highly coupled Riccati-like matrix difference equations. Results can be used for off-line studies relating the open loop dynamics, required performance, actuator mean time to failure, and functional or identical actuator redundancy, with and without feedback gain reconfiguration strategies.
LIGHT EXPOSURE AMONG ADOLESCENTS WITH DELAYED SLEEP PHASE DISORDER: A PROSPECTIVE COHORT STUDY
Auger, R. Robert; Burgess, Helen J.; Dierkhising, Ross A.; Sharma, Ruchi G.; Slocumb, Nancy L.
2012-01-01
Our study objective was to compare light exposure and sleep parameters between adolescents with delayed sleep phase disorder (n=16, 15.3 ± 1.8 years) and unaffected controls (n=22, 13.7 ± 2.4 years) using a prospective cohort design. Participants wore wrist actigraphs with photosensors for 14 days. Mean hourly lux levels from 20:00-05:00 h and 05:00-14:00 h were examined, in addition to the 9-hour intervals prior to sleep onset and after sleep offset. Sleep parameters were compared separately, and were also included as covariates within models that analyzed associations with specified light intervals. Additional covariates included group and school night status. Adolescent subjects with delayed sleep phase disorder received more evening (p<0.02, 22:00-02:00 h) and less morning light (p<0.05, 08:00-09:00 h and 10:00-12:00 h) than controls, but had less pre-sleep exposure with adjustments for the time of sleep onset (p<0.03, fifth-seventh hours prior to onset hour). No differences were identified with respect to the sleep offset interval. Increased total sleep time and later sleep offset times were associated with decreased evening (p<0.001 and p=0.02, respectively) and morning (p=0.01 and p<0.001, respectively) exposure, and later sleep onset times were associated with increased evening exposure (p<0.001). Increased total sleep time also correlated with increased exposure during the 9 hours before sleep-onset (p=0.01), and a later sleep onset time corresponded with decreased exposure during the same interval (p<0.001). Outcomes persisted regardless of school night status. In conclusion, light exposure interpretation requires adjustments for sleep timing among adolescents with delayed sleep phase disorder. Pre- and post-sleep exposure do not appear to contribute directly to phase delays. Sensitivity to morning light may be reduced among adolescents with delayed sleep phase disorder. PMID:22080736
Asayama, Kei; Thijs, Lutgarde; Li, Yan; Gu, Yu-Mei; Hara, Azusa; Liu, Yan-Ping; Zhang, Zhenyu; Wei, Fang-Fei; Lujambio, Inés; Mena, Luis J.; Boggia, José; Hansen, Tine W.; Björklund-Bodegård, Kristina; Nomura, Kyoko; Ohkubo, Takayoshi; Jeppesen, Jørgen; Torp-Pedersen, Christian; Dolan, Eamon; Stolarz-Skrzypek, Katarzyna; Malyutina, Sofia; Casiglia, Edoardo; Nikitin, Yuri; Lind, Lars; Luzardo, Leonella; Kawecka-Jaszcz, Kalina; Sandoya, Edgardo; Filipovský, Jan; Maestre, Gladys E.; Wang, Jiguang; Imai, Yutaka; Franklin, Stanley S.; O’Brien, Eoin; Staessen, Jan A.
2015-01-01
Outcome-driven recommendations about time intervals during which ambulatory blood pressure should be measured to diagnose white-coat or masked hypertension are lacking. We cross-classified 8237 untreated participants (mean age, 50.7 years; 48.4% women) enrolled in 12 population studies, using ≥140/≥90, ≥130/≥80, ≥135/≥85, and ≥120/≥70 mm Hg as hypertension thresholds for conventional, 24-hour, daytime, and nighttime blood pressure. White-coat hypertension was hypertension on conventional measurement with ambulatory normotension, the opposite condition being masked hypertension. Intervals used for classification of participants were daytime, nighttime, and 24 hours, first considered separately, and next combined as 24 hours plus daytime or plus nighttime, or plus both. Depending on time intervals chosen, white-coat and masked hypertension frequencies ranged from 6.3% to 12.5% and from 9.7% to 19.6%, respectively. During 91 046 person-years, 729 participants experienced a cardiovascular event. In multivariable analyses with normotension during all intervals of the day as reference, hazard ratios associated with white-coat hypertension progressively weakened considering daytime only (1.38; P=0.033), nighttime only (1.43; P=0.0074), 24 hours only (1.21; P=0.20), 24 hours plus daytime (1.24; P=0.18), 24 hours plus nighttime (1.15; P=0.39), and 24 hours plus daytime and nighttime (1.16; P=0.41). The hazard ratios comparing masked hypertension with normotension were all significant (P<0.0001), ranging from 1.76 to 2.03. In conclusion, identification of truly low-risk white-coat hypertension requires setting thresholds simultaneously to 24 hours, daytime, and nighttime blood pressure. Although any time interval suffices to diagnose masked hypertension, as proposed in current guidelines, full 24-hour recordings remain standard in clinical practice. PMID:25135185
Determinants of reinforcer accumulation during an operant task.
McFarland, J M; Lattal, K A
2001-11-01
Responses by rats on an earn lever made available food pellets that were delivered to a food cup by responses on a second, collect, lever. The rats could either collect and immediately consume or accumulate (defined as the percentage of multiple earn responses and as the number of pellets earned before a collect response) earned pellets. In Experiment 1, accumulation varied as a function of variations in the earn or collect response requirements and whether the earn and collect levers were proximal (31 cm) or distal (248 cm) to one another. Some accumulation occurred under all but one of the conditions, but generally was higher when the earn and collect levers were distal to one another, particularly when the earn response requirement was fixed-ratio (FR) 1. In Experiment 2, the contributions of responses and time to accumulation were assessed by comparing an FR 20 earn response requirement to a condition in which only a single earn response was required at the end of a time interval nominally yoked to the FR interval. When 248 cm separated the earn and collect levers, accumulation was always greater in the FR condition, and it was not systematically related to reinforcement rate. In Experiment 3, increasing the earn response requirement with a progressive-ratio schedule that reset only with a collect response increased the likelihood of accumulation when the collect and earn levers were 248 cm apart, even though such accumulation increased the next earn response requirement. Reinforcer accumulation is an understudied dimension of operant behavior that relates to the analysis of such phenomena as hoarding and self-control, in that they too involve accumulating versus immediately collecting or consuming reinforcers.
Determinants of reinforcer accumulation during an operant task.
McFarland, J M; Lattal, K A
2001-01-01
Responses by rats on an earn lever made available food pellets that were delivered to a food cup by responses on a second, collect, lever. The rats could either collect and immediately consume or accumulate (defined as the percentage of multiple earn responses and as the number of pellets earned before a collect response) earned pellets. In Experiment 1, accumulation varied as a function of variations in the earn or collect response requirements and whether the earn and collect levers were proximal (31 cm) or distal (248 cm) to one another. Some accumulation occurred under all but one of the conditions, but generally was higher when the earn and collect levers were distal to one another, particularly when the earn response requirement was fixed-ratio (FR) 1. In Experiment 2, the contributions of responses and time to accumulation were assessed by comparing an FR 20 earn response requirement to a condition in which only a single earn response was required at the end of a time interval nominally yoked to the FR interval. When 248 cm separated the earn and collect levers, accumulation was always greater in the FR condition, and it was not systematically related to reinforcement rate. In Experiment 3, increasing the earn response requirement with a progressive-ratio schedule that reset only with a collect response increased the likelihood of accumulation when the collect and earn levers were 248 cm apart, even though such accumulation increased the next earn response requirement. Reinforcer accumulation is an understudied dimension of operant behavior that relates to the analysis of such phenomena as hoarding and self-control, in that they too involve accumulating versus immediately collecting or consuming reinforcers. PMID:11768714
A good time to leave?: the sunk time effect in pigeons.
Magalhães, Paula; White, K Geoffrey
2014-06-01
Persistence in a losing course of action due to prior investments of time, known as the sunk time effect, has seldom been studied in nonhuman animals. On every trial in the present study, pigeons were required to choose between two response keys. Responses on one key produced food after a short fixed interval (FI) of time on some trials, or on other trials, no food (Extinction) after a longer time. FI and Extinction trials were not differently signaled, were equiprobable, and alternated randomly. Responses on a second Escape key allowed the pigeon to terminate the current trial and start a new one. The optimal behavior was for pigeons to peck the escape key once the duration equivalent to the short FI had elapsed without reward. Durations of the short FI and the longer Extinction schedules were varied over conditions. In some conditions, the pigeons suboptimally responded through the Extinction interval, thus committing the sunk time effect. The absolute duration of the short FI had no effect on the choice between persisting and escaping. Instead, the ratio of FI and Extinction durations determined the likelihood of persistence during extinction. Copyright © 2014 Elsevier B.V. All rights reserved.
Characterization of Fissile Assemblies Using Low-Efficiency Detection Systems
Chapline, George F.; Verbeke, Jerome M.
2017-02-02
Here, we have investigated the possibility that the amount, chemical form, multiplication, and shape of the fissile material in an assembly can be passively assayed using scintillator detection systems by only measuring the fast neutron pulse height distribution and distribution of time intervals Δt between fast neutrons. We have previously demonstrated that the alpha-ratio can be obtained from the observed pulse height distribution for fast neutrons. In this paper we report that we report that when the distribution of time intervals is plotted as a function of logΔt, the position of the correlated neutron peak is nearly independent of detectormore » efficiency and determines the internal relaxation rate for fast neutrons. If this information is combined with knowledge of the alpha-ratio, then the position of the minimum between the correlated and uncorrelated peaks can be used to rapidly estimate the mass, multiplication, and shape of fissile material. This method does not require a priori knowledge of either the efficiency for neutron detection or the alpha-ratio. Although our method neglects 3-neutron correlations, we have used previously obtained experimental data for metallic and oxide forms of Pu to demonstrate that our method yields good estimates for multiplications as large as 2, and that the only constraint on detector efficiency/observation time is that a peak in the interval time distribution due to correlated neutrons is visible.« less
Evaluating the risk of decompression sickness for a yo-yo dive using a rat model.
Ofir, Dror; Yanir, Yoav; Abramovich, Amir; Bar, Ronen; Arieli, Yehuda
2016-01-01
The frequent ascents made during yo-yo diving may contribute to gas bubble clearance but paradoxically may also increase the risk of central nervous system decompression illness (DCI). We evaluated the risk of DCI due to yo-yo dives with very short surface intervals, using a controlled animal model. Dives were conducted on air to a depth of 90 meters (10 atmospheres absolute) for 32 minutes of bottom time, at a descent/ascent rate of 10 meters/ minute. Sprague-Dawley rats weighing ~ 300 grams were divided randomly into three groups. Group A performed a square dive protocol without any surface intervals, Group B conducted a protocol that included two surface intervals during the dive, and Group C performed a protocol with three surface intervals. Ascent/descent rate for surface intervals, each lasting one minute, was also 10 meters/minute. Manifestations of DCI were observed in 13 of 16 animals in Group A (81.3%), six of 12 in Group B (58.3%), and two of 12 in Group C (16.7%). Mortality rates were similar in all groups. Surface intervals during dives breathing air significantly reduced DCI risk in the rat. Further studies are required using a larger animal model to reinforce the results of the present investigation.
Sui, Yuanyuan; Ou, Yang; Yan, Baixing; Xu, Xiaohong; Rousseau, Alain N; Zhang, Yu
2016-01-01
Micro-basin tillage is a soil and water conservation practice that requires building individual earth blocks along furrows. In this study, plot experiments were conducted to assess the efficiency of micro-basin tillage on sloping croplands between 2012 and 2013 (5°and 7°). The conceptual, optimal, block interval model was used to design micro-basins which are meant to capture the maximum amount of water per unit area. Results indicated that when compared to the up-down slope tillage, micro-basin tillage could increase soil water content and maize yield by about 45% and 17%, and reduce runoff, sediment and nutrients loads by about 63%, 96% and 86%, respectively. Meanwhile, micro-basin tillage could reduce the peak runoff rates and delay the initial runoff-yielding time. In addition, micro-basin tillage with the optimal block interval proved to be the best one among all treatments with different intervals. Compared with treatments of other block intervals, the optimal block interval treatments increased soil moisture by around 10% and reduced runoff rate by around 15%. In general, micro-basin tillage with optimal block interval represents an effective soil and water conservation practice for sloping farmland of the black soil region.
Sui, Yuanyuan; Ou, Yang; Yan, Baixing; Xu, Xiaohong; Rousseau, Alain N.; Zhang, Yu
2016-01-01
Micro-basin tillage is a soil and water conservation practice that requires building individual earth blocks along furrows. In this study, plot experiments were conducted to assess the efficiency of micro-basin tillage on sloping croplands between 2012 and 2013 (5°and 7°). The conceptual, optimal, block interval model was used to design micro-basins which are meant to capture the maximum amount of water per unit area. Results indicated that when compared to the up-down slope tillage, micro-basin tillage could increase soil water content and maize yield by about 45% and 17%, and reduce runoff, sediment and nutrients loads by about 63%, 96% and 86%, respectively. Meanwhile, micro-basin tillage could reduce the peak runoff rates and delay the initial runoff-yielding time. In addition, micro-basin tillage with the optimal block interval proved to be the best one among all treatments with different intervals. Compared with treatments of other block intervals, the optimal block interval treatments increased soil moisture by around 10% and reduced runoff rate by around 15%. In general, micro-basin tillage with optimal block interval represents an effective soil and water conservation practice for sloping farmland of the black soil region. PMID:27031339
The matching law in and within groups of rats1
Graft, D. A.; Lea, S. E. G.; Whitworth, T. L.
1977-01-01
In each of the two experiments, a group of five rats lived in a complex maze containing four small single-lever operant chambers. In two of these chambers, food was available on variable-interval schedules of reinforcement. In Experiment I, nine combinations of variable intervals were used, and the aggregate lever-pressing rates (by the five rats together) were studied. The log ratio of the rates in the two chambers was linearly related to the log ratio of the reinforcement rates in them; this is an instance of Herrnstein's matching law, as generalized by Baum. Summing over the two food chambers, food consumption decreased, and response output increased, as the time required to earn each pellet increased. In Experiment II, the behavior of individual rats was observed by time-sampling on selected days, while different variable-interval schedules were arranged in the two chambers where food was available. Individual lever-pressing rates for the rats were obtained, and their median bore the same “matching” relationship to the reinforcement rates as the group aggregate in Experiment I. There were differences between the rats in their distribution of time and responses between the two food chambers; these differences were correlated with differences in the proportions of reinforcements the rats obtained from each chamber. PMID:16811975
Generalized Riemann hypothesis and stochastic time series
NASA Astrophysics Data System (ADS)
Mussardo, Giuseppe; LeClair, André
2018-06-01
Using the Dirichlet theorem on the equidistribution of residue classes modulo q and the Lemke Oliver–Soundararajan conjecture on the distribution of pairs of residues on consecutive primes, we show that the domain of convergence of the infinite product of Dirichlet L-functions of non-principal characters can be extended from down to , without encountering any zeros before reaching this critical line. The possibility of doing so can be traced back to a universal diffusive random walk behavior of a series C N over the primes which underlies the convergence of the infinite product of the Dirichlet functions. The series C N presents several aspects in common with stochastic time series and its control requires to address a problem similar to the single Brownian trajectory problem in statistical mechanics. In the case of the Dirichlet functions of non principal characters, we show that this problem can be solved in terms of a self-averaging procedure based on an ensemble of block variables computed on extended intervals of primes. Those intervals, called inertial intervals, ensure the ergodicity and stationarity of the time series underlying the quantity C N . The infinity of primes also ensures the absence of rare events which would have been responsible for a different scaling behavior than the universal law of the random walks.
The Impact of Surgical Timing in Acute Traumatic Spinal Cord Injury
2016-10-01
However, their study was con - ducted with a small sample of 63 patients and only cer- vical T-SCI, and did not account for other possible factors that... con - tributors are the time of transfer from the site of trauma to the SCI center, the interval between the first medical assessment and surgical plan...requiring surgery will depend upon the availability of the operating rooms and of the spine surgeons, con - sidering the high number of elective cases
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-12
..., repeat the inspection required by paragraph (f) of this AD at intervals not to exceed 9,000 landings, in... inspection required by paragraph (f) of this AD at intervals not to exceed 9,000 landings, in accordance with..., dated October 15, 2007. Repeat the inspections thereafter at intervals not to exceed 4,000 flight cycles...
Map based navigation for autonomous underwater vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tuohy, S.T.; Leonard, J.J.; Bellingham, J.G.
1995-12-31
In this work, a map based navigation algorithm is developed wherein measured geophysical properties are matched to a priori maps. The objectives is a complete algorithm applicable to a small, power-limited AUV which performs in real time to a required resolution with bounded position error. Interval B-Splines are introduced for the non-linear representation of two-dimensional geophysical parameters that have measurement uncertainty. Fine-scale position determination involves the solution of a system of nonlinear polynomial equations with interval coefficients. This system represents the complete set of possible vehicle locations and is formulated as the intersection of contours established on each map frommore » the simultaneous measurement of associated geophysical parameters. A standard filter mechanisms, based on a bounded interval error model, predicts the position of the vehicle and, therefore, screens extraneous solutions. When multiple solutions are found, a tracking mechanisms is applied until a unique vehicle location is determined.« less
Ávila Ramírez, Jhon Alejandro; Gómez Hoyos, Catalina; Arroyo, Silvana; Cerrutti, Patricia; Foresti, María Laura
2016-11-20
Bacterial cellulose (BC) nanoribbons were partially acetylated by a simple direct solvent-free route catalyzed by citric acid. The assay of reaction conditions within chosen intervals (i.e. esterification time (0.5-7h), catalyst content (0.08-1.01mmol/mmol AGU), and temperature (90-140°C)), illustrated the flexibility of the methodology proposed, with reaction variables which can be conveniently manipulated to acetylate BC to the required degree of substitution (DS) within the 0.20-0.73 interval. Within this DS interval, characterization results indicated a surface-only process in which acetylated bacterial cellulose with tunable DS, preserved fibrous structure and increased hydrophobicity could be easily obtained. The feasibility of reusing the catalyst/excess acylant in view of potential scale-up was also illustrated. Copyright © 2016 Elsevier Ltd. All rights reserved.
Effects of anesthetic agents on in vivo axonal HCN current in normal mice.
Osaki, Yusuke; Nodera, Hiroyuki; Banzrai, Chimeglkham; Endo, Sachiko; Takayasu, Hirokazu; Mori, Atsuko; Shimatani, Yoshimitsu; Kaji, Ryuji
2015-10-01
The objective was to study the in vivo effects of anesthetic agents on peripheral nerve excitability. Normal male mice were anesthetized by either isoflurane inhalation or a combination of medetomidine, midazolam, and butorphanol intraperitoneal injection ("triple agents"). Immediately after induction, the tail sensory nerve action potential was recorded and its excitability was monitored. Under both anesthetic protocols, there was an interval excitability change by long hyperpolarizing currents. There was greater threshold reduction approximately 30min post induction, in comparison to immediately post induction. Other excitability parameters were stable over time. Modeling suggested interval suppression of internodal H conductance or leak current. Anesthetic agents affected responses to long hyperpolarizing currents. Axonal excitability during intraoperative monitoring may be affected by anesthetic agents. Interpretation of interval excitability changes under anesthesia requires caution, especially with long hyperpolarizing currents. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
INTERIOR VIEW OF JAMES HARRIS CUTTING SCREW THREADS INTO THE ...
INTERIOR VIEW OF JAMES HARRIS CUTTING SCREW THREADS INTO THE INTERIOR OF FITTINGS ON ONE IN A BANK OF TAPPING MACHINES, EACH OPERATED BY THE SAME WORKER SIMULTANEOUSLY BUT TIMED TO REQUIRE WORKER ACTION AT INTERVALS THAT DO NOT INTERFERE WITH THE OTHER MACHINES. - Stockham Pipe & Fittings Company, Tapping Room, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
El Amrani, Abdel-Ilah; El Amrani-Callens, Francine; Loriot, Stéphane; Singh, Pramila; Forster, Roy
2016-01-01
Cardiovascular safety assessment requires accurate evaluation of QT interval, which depends on the length of the cardiac cycle and also on core body temperature (BT). Increases in QT interval duration have been shown to be associated with decreases in BT in dogs. An example of altered QT interval duration associated with changes in body temperature observed during a 4-week regulatory toxicology study in dogs is presented. Four groups of Beagle dogs received the vehicle or test item once on Day 1, followed by a 4-week observation period. Electrocardiogram (ECG) parameters were continuously recorded on Days 1 and 26 by jacketed external telemetry (JET). Core body temperature (BT) was measured with a conventional rectal thermometer at appropriate time-points during the Day 1 recording period. Decreased BT was observed approximately 2h after treatment on Day 1, along with increased QT interval duration corrected according to the Van de Water formula (QTcV), but the effect was no longer observed after correction for changes in BT [QTcVcT=QTcV-14(37.5-BT)] according to the Van der Linde formula. No significant changes in QTcV were reported at the end of the observation period, on Day 26. The present study demonstrates that core body (rectal) temperature can easily be monitored at appropriate time-points during JET recording in regulatory toxicology studies in dogs, in order to correct QT interval duration values for treatment-related changes in BT. The successful application of the Van der Linde formula to correct QTc prolongation for changes in BT was demonstrated. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Tao, Siying; Li, Lan; Yuan, He; Tao, Sibei; Cheng, Yiming; He, Libang; Li, Jiyao
2017-12-01
The study aimed to assess the efficacy of erbium laser technology compared with traditional drilling for caries removal. A systematic search was conducted through Medline via PubMed, Embase, Cochrane databases, CNKI till December 2016. Randomised controlled trials, quasi-randomized controlled trials, or controlled clinical trials with data comparing the efficacy of erbium laser technology versus traditional drilling for caries removal were included. Fourteen studies were selected in our meta-analysis. Erbium laser technology showed an increased time when removing caries compared with drilling (mean difference: 3.48, 95% confidence interval: 1.90-5.06, P < .0001). However, erbium laser technology reduced the requirement for local anesthesia (risk ratio: 0.28, 95% confidence interval: 0.13-0.62, P = .002). Erbium laser technology was also not significantly different to traditional drilling with regard to restoration loss, pulpal vitality, and postoperative sensitivity. Erbium laser technology showed an increased time for cavity preparation compared with traditional drilling. However, erbium laser technology reduced the requirement for local anesthesia. There was no significant difference between erbium laser technology and traditional drilling regarding restoration loss, pulpal vitality, and postoperative sensitivity. Copyright © 2017 Elsevier Inc. All rights reserved.
Uchida, Thomas K.; Sherman, Michael A.; Delp, Scott L.
2015-01-01
Impacts are instantaneous, computationally efficient approximations of collisions. Current impact models sacrifice important physical principles to achieve that efficiency, yielding qualitative and quantitative errors when applied to simultaneous impacts in spatial multibody systems. We present a new impact model that produces behaviour similar to that of a detailed compliant contact model, while retaining the efficiency of an instantaneous method. In our model, time and configuration are fixed, but the impact is resolved into distinct compression and expansion phases, themselves comprising sliding and rolling intervals. A constrained optimization problem is solved for each interval to compute incremental impulses while respecting physical laws and principles of contact mechanics. We present the mathematical model, algorithms for its practical implementation, and examples that demonstrate its effectiveness. In collisions involving materials of various stiffnesses, our model can be more than 20 times faster than integrating through the collision using a compliant contact model. This work extends the use of instantaneous impact models to scientific and engineering applications with strict accuracy requirements, where compliant contact models would otherwise be required. An open-source implementation is available in Simbody, a C++ multibody dynamics library widely used in biomechanical and robotic applications. PMID:27547093
On a Solar Origin for the Cosmogenic Nuclide Event of 775 A.D.
NASA Technical Reports Server (NTRS)
Cliver, E. W.; Tylka, A. J.; Dietrich, W. F.; Ling, A. G.
2014-01-01
We explore requirements for a solar particle event (SPE) and flare capable of producing the cosmogenic nuclide event of 775 A.D., and review solar circumstances at that time. A solar source for 775 would require a greater than 1 GV spectrum approximately 45 times stronger than that of the intense high-energy SPE of 1956 February 23. This implies a greater than 30 MeV proton fluence (F(sub 30)) of approximately 8 × 10(exp 10) proton cm(exp -2), approximately 10 times larger than that of the strongest 3 month interval of SPE activity in the modern era. This inferred F(sub 30) value for the 775 SPE is inconsistent with the occurrence probability distribution for greater than 30 MeV solar proton events. The best guess value for the soft X-ray classification (total energy) of an associated flare is approximately X230 (approximately 9 × 10(exp 33) erg). For comparison, the flares on 2003 November 4 and 1859 September 1 had observed/inferred values of approximately X35 (approximately 10(exp 33) erg) and approximately X45 (approximately 2 × 10(exp 33) erg), respectively. The estimated size of the source active region for a approximately 10(exp 34) erg flare is approximately 2.5 times that of the largest region yet recorded. The 775 event occurred during a period of relatively low solar activity, with a peak smoothed amplitude about half that of the second half of the 20th century. The approximately 1945-1995 interval, the most active of the last approximately 2000 yr, failed to witness a SPE comparable to that required for the proposed solar event in 775. These considerations challenge a recent suggestion that the 775 event is likely of solar origin.
Kumar, Anupam; Kumar, Vijay
2017-05-01
In this paper, a novel concept of an interval type-2 fractional order fuzzy PID (IT2FO-FPID) controller, which requires fractional order integrator and fractional order differentiator, is proposed. The incorporation of Takagi-Sugeno-Kang (TSK) type interval type-2 fuzzy logic controller (IT2FLC) with fractional controller of PID-type is investigated for time response measure due to both unit step response and unit load disturbance. The resulting IT2FO-FPID controller is examined on different delayed linear and nonlinear benchmark plants followed by robustness analysis. In order to design this controller, fractional order integrator-differentiator operators are considered as design variables including input-output scaling factors. A new hybridized algorithm named as artificial bee colony-genetic algorithm (ABC-GA) is used to optimize the parameters of the controller while minimizing weighted sum of integral of time absolute error (ITAE) and integral of square of control output (ISCO). To assess the comparative performance of the IT2FO-FPID, authors compared it against existing controllers, i.e., interval type-2 fuzzy PID (IT2-FPID), type-1 fractional order fuzzy PID (T1FO-FPID), type-1 fuzzy PID (T1-FPID), and conventional PID controllers. Furthermore, to show the effectiveness of the proposed controller, the perturbed processes along with the larger dead time are tested. Moreover, the proposed controllers are also implemented on multi input multi output (MIMO), coupled, and highly complex nonlinear two-link robot manipulator system in presence of un-modeled dynamics. Finally, the simulation results explicitly indicate that the performance of the proposed IT2FO-FPID controller is superior to its conventional counterparts in most of the cases. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
49 CFR 192.939 - What are the required reassessment intervals?
Code of Federal Regulations, 2013 CFR
2013-10-01
... Transmission Pipeline Integrity Management § 192.939 What are the required reassessment intervals? An operator... stress levels of pipeline (operating at or above 30% SMYS) listed in ASME/ANSI B31.8S, section 5, Table 3... equivalent technology following the requirements in paragraph (a)(1) of this section except that the stress...
49 CFR 192.939 - What are the required reassessment intervals?
Code of Federal Regulations, 2011 CFR
2011-10-01
... Transmission Pipeline Integrity Management § 192.939 What are the required reassessment intervals? An operator... stress levels of pipeline (operating at or above 30% SMYS) listed in ASME/ANSI B31.8S, section 5, Table 3... equivalent technology following the requirements in paragraph (a)(1) of this section except that the stress...
49 CFR 192.939 - What are the required reassessment intervals?
Code of Federal Regulations, 2012 CFR
2012-10-01
... Transmission Pipeline Integrity Management § 192.939 What are the required reassessment intervals? An operator... stress levels of pipeline (operating at or above 30% SMYS) listed in ASME/ANSI B31.8S, section 5, Table 3... equivalent technology following the requirements in paragraph (a)(1) of this section except that the stress...
49 CFR 192.939 - What are the required reassessment intervals?
Code of Federal Regulations, 2014 CFR
2014-10-01
... Transmission Pipeline Integrity Management § 192.939 What are the required reassessment intervals? An operator... stress levels of pipeline (operating at or above 30% SMYS) listed in ASME/ANSI B31.8S, section 5, Table 3... equivalent technology following the requirements in paragraph (a)(1) of this section except that the stress...
Cheng, Steven K; Dietrich, Mary S; Dilts, David M
2010-11-15
Postactivation barriers to oncology clinical trial accruals are well documented; however, potential barriers prior to trial opening are not. We investigate one such barrier: trial development time. National Cancer Institute Cancer Therapy Evaluation Program (CTEP)-sponsored trials for all therapeutic, nonpediatric phase I, I/II, II, and III studies activated between 2000 and 2004 were investigated for an 8-year period (n = 419). Successful trials were those achieving 100% of minimum accrual goal. Time to open a study was the calendar time from initial CTEP submission to trial activation. Multivariate logistic regression analysis was used to calculate unadjusted and adjusted odds ratios (OR), controlling for study phase and size of expected accruals. Among the CTEP-approved oncology trials, 37.9% (n = 221) failed to attain the minimum accrual goals, with 70.8% (n = 14) of phase III trials resulting in poor accrual. A total of 16,474 patients (42.5% of accruals) accrued to those studies were unable to achieve the projected minimum accrual goal. Trials requiring less than 12 months of development were significantly more likely to achieve accrual goals (OR, 2.15; 95% confidence interval, 1.29-3.57, P = 0.003) than trials with the median development times of 12 to 18 months. Trials requiring a development time of greater than 24 months were significantly less likely to achieve accrual goals (OR, 0.40; 95% confidence interval, 0.20-0.78; P = 0.011) than trials with the median development time. A large percentage of oncology clinical trials do not achieve minimum projected accruals. Trial development time appears to be one important predictor of the likelihood of successfully achieving the minimum accrual goals. ©2010 AACR.
Effect of rest interval on strength recovery in young and old women.
Theou, Olga; Gareth, Jones R; Brown, Lee E
2008-11-01
This study compares the effects of rest intervals on isokinetic muscle torque recovery between sets of a knee extensor and flexor exercise protocol in physically active younger and older women. Twenty young (22.4 +/- 1.7 years) and 16 older (70.7 +/- 4.3 years) women performed three sets of eight maximum repetitions of knee extension/flexion at 60 degrees x s(-1). The rest interval between sets was 15, 30, and 60 seconds and was randomly assigned across three testing days. No significant interaction of rest by set by age group was observed. There was a significant decline in mean knee extensor torque when 15- and 30-second rest intervals were used between sets, but not when a 60-second rest interval was applied for both the young and the old women. No significant decline for mean knee flexor torque was observed in the older women when a 30-second rest interval was used, whereas a longer 60-second rest interval was required in younger women. Active younger and older women require similar rest intervals between sets of a knee extensor exercise (60 seconds) for complete recovery. However, older women recovered faster (30 seconds) than younger women (60 seconds) between sets of a knee flexor exercise. The exercise-to-rest ratio for knee extensors was similar for young and old women (1:2). Old women required only a 1:1 exercise-to-rest ratio for knee flexor recovery, whereas younger women required a longer 1:2 exercise-to-rest ratio. The results of the present study are specific to isokinetic testing and training and are more applicable in rehabilitation and research settings. Practitioners should consider age and gender when prescribing rest intervals between sets.
Ratio-based lengths of intervals to improve fuzzy time series forecasting.
Huarng, Kunhuang; Yu, Tiffany Hui-Kuang
2006-04-01
The objective of this study is to explore ways of determining the useful lengths of intervals in fuzzy time series. It is suggested that ratios, instead of equal lengths of intervals, can more properly represent the intervals among observations. Ratio-based lengths of intervals are, therefore, proposed to improve fuzzy time series forecasting. Algebraic growth data, such as enrollments and the stock index, and exponential growth data, such as inventory demand, are chosen as the forecasting targets, before forecasting based on the various lengths of intervals is performed. Furthermore, sensitivity analyses are also carried out for various percentiles. The ratio-based lengths of intervals are found to outperform the effective lengths of intervals, as well as the arbitrary ones in regard to the different statistical measures. The empirical analysis suggests that the ratio-based lengths of intervals can also be used to improve fuzzy time series forecasting.
Kim, Tae Kyung; Kim, Hyung Wook; Kim, Su Jin; Ha, Jong Kun; Jang, Hyung Ha; Hong, Young Mi; Park, Su Bum; Choi, Cheol Woong; Kang, Dae Hwan
2014-01-01
Background/Aims The quality of bowel preparation (QBP) is the important factor in performing a successful colonoscopy. Several factors influencing QBP have been reported; however, some factors, such as the optimal preparation-to-colonoscopy time interval, remain controversial. This study aimed to determine the factors influencing QBP and the optimal time interval for full-dose polyethylene glycol (PEG) preparation. Methods A total of 165 patients who underwent colonoscopy from June 2012 to August 2012 were prospectively evaluated. The QBP was assessed using the Ottawa Bowel Preparation Scale (Ottawa) score according to several factors influencing the QBP were analyzed. Results Colonoscopies with a time interval of 5 to 6 hours had the best Ottawa score in all parts of the colon. Patients with time intervals of 6 hours or less had the better QBP than those with time intervals of more than 6 hours (p=0.046). In the multivariate analysis, the time interval (odds ratio, 1.897; 95% confidence interval, 1.006 to 3.577; p=0.048) was the only significant contributor to a satisfactory bowel preparation. Conclusions The optimal time was 5 to 6 hours for the full-dose PEG method, and the time interval was the only significant contributor to a satisfactory bowel preparation. PMID:25368750
Segundo, J P; Sugihara, G; Dixon, P; Stiber, M; Bersier, L F
1998-12-01
This communication describes the new information that may be obtained by applying nonlinear analytical techniques to neurobiological time-series. Specifically, we consider the sequence of interspike intervals Ti (the "timing") of trains recorded from synaptically inhibited crayfish pacemaker neurons. As reported earlier, different postsynaptic spike train forms (sets of timings with shared properties) are generated by varying the average rate and/or pattern (implying interval dispersions and sequences) of presynaptic spike trains. When the presynaptic train is Poisson (independent exponentially distributed intervals), the form is "Poisson-driven" (unperturbed and lengthened intervals succeed each other irregularly). When presynaptic trains are pacemaker (intervals practically equal), forms are either "p:q locked" (intervals repeat periodically), "intermittent" (mostly almost locked but disrupted irregularly), "phase walk throughs" (intermittencies with briefer regular portions), or "messy" (difficult to predict or describe succinctly). Messy trains are either "erratic" (some intervals natural and others lengthened irregularly) or "stammerings" (intervals are integral multiples of presynaptic intervals). The individual spike train forms were analysed using attractor reconstruction methods based on the lagged coordinates provided by successive intervals from the time-series Ti. Numerous models were evaluated in terms of their predictive performance by a trial-and-error procedure: the most successful model was taken as best reflecting the true nature of the system's attractor. Each form was characterized in terms of its dimensionality, nonlinearity and predictability. (1) The dimensionality of the underlying dynamical attractor was estimated by the minimum number of variables (coordinates Ti) required to model acceptably the system's dynamics, i.e. by the system's degrees of freedom. Each model tested was based on a different number of Ti; the smallest number whose predictions were judged successful provided the best integer approximation of the attractor's true dimension (not necessarily an integer). Dimensionalities from three to five provided acceptable fits. (2) The degree of nonlinearity was estimated by: (i) comparing the correlations between experimental results and data from linear and nonlinear models, and (ii) tuning model nonlinearity via a distance-weighting function and identifying the either local or global neighborhood size. Lockings were compatible with linear models and stammerings were marginal; nonlinear models were best for Poisson-driven, intermittent and erratic forms. (3) Finally, prediction accuracy was plotted against increasingly long sequences of intervals forecast: the accuracies for Poisson-driven, locked and stammering forms were invariant, revealing irregularities due to uncorrelated noise, but those of intermittent and messy erratic forms decayed rapidly, indicating an underlying deterministic process. The excellent reconstructions possible for messy erratic and for some intermittent forms are especially significant because of their relatively low dimensionality (around 4), high degree of nonlinearity and prediction decay with time. This is characteristic of chaotic systems, and provides evidence that nonlinear couplings between relatively few variables are the major source of the apparent complexity seen in these cases. This demonstration of different dimensions, degrees of nonlinearity and predictabilities provides rigorous support for the categorization of different synaptically driven discharge forms proposed earlier on the basis of more heuristic criteria. This has significant implications. (1) It demonstrates that heterogeneous postsynaptic forms can indeed be induced by manipulating a few presynaptic variables. (2) Each presynaptic timing induces a form with characteristic dimensionality, thus breaking up the preparation into subsystems such that the physical variables in each operate as one
Interresponse Time Structures in Variable-Ratio and Variable-Interval Schedules
ERIC Educational Resources Information Center
Bowers, Matthew T.; Hill, Jade; Palya, William L.
2008-01-01
The interresponse-time structures of pigeon key pecking were examined under variable-ratio, variable-interval, and variable-interval plus linear feedback schedules. Whereas the variable-ratio and variable-interval plus linear feedback schedules generally resulted in a distinct group of short interresponse times and a broad distribution of longer…
Application of carbon nanotube hold-off voltage for determining gas composition
NASA Technical Reports Server (NTRS)
Schipper, John F. (Inventor); Li, Jing (Inventor)
2009-01-01
Method and system for determining chemical composition of a single-component or multiple-component gas, using a discharge holdoff mechanism. A voltage difference V between two spaced apart electrodes is brought to a selected value and held, the holdoff time interval .DELTA.t(V;ho) required before gas discharge occurs is measured, and the associated electrical current or cumulative electrical charge is measured. As the voltage difference V increases, the time interval length .DELTA.t(V;ho) decreases monotonically. Particular voltage values, V.sub..infin. and V.sub.0, correspond to initial appearance of discharge (.DELTA.t.apprxeq..infin.) and prompt discharge (.DELTA.t.apprxeq.0). The values V.sub..infin. and V.sub.0 and the rate of decrease of .DELTA.t(V;ho) and/or the rate of increase of current or cumulative charge with increasing V are characteristic of one or more gas components present.
An apparatus for sequentially combining microvolumes of reagents by infrasonic mixing.
Camien, M N; Warner, R C
1984-05-01
A method employing high-speed infrasonic mixing for obtaining timed samples for following the progress of a moderately rapid chemical reaction is described. Drops of 10 to 50 microliter each of two reagents are mixed to initiate the reaction, followed, after a measured time interval, by mixing with a drop of a third reagent to quench the reaction. The method was developed for measuring the rate of denaturation of covalently closed, circular DNA in NaOH at several temperatures. For this purpose the timed samples were analyzed by analytical ultracentrifugation. The apparatus was tested by determination of the rate of hydrolysis of 2,4-dinitrophenyl acetate in an alkaline buffer. The important characteristics of the method are (i) it requires very small volumes of sample and reagents; (ii) the components of the reaction mixture are pre-equilibrated and mixed with no transfer outside the prescribed constant temperature environment; (iii) the mixing is very rapid; and (iv) satisfactorily precise measurements of relatively short time intervals (approximately 2 sec minimum) between sequential mixings of the components are readily obtainable.
Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk.
Fleg, Jerome L
2016-01-01
Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation.
Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk
Fleg, Jerome L.
2016-01-01
Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation. PMID:27635241
Sleep deprivation and time-on-task performance decrement in the rat psychomotor vigilance task.
Oonk, Marcella; Davis, Christopher J; Krueger, James M; Wisor, Jonathan P; Van Dongen, Hans P A
2015-03-01
The rat psychomotor vigilance task (rPVT) was developed as a rodent analog of the human psychomotor vigilance task (hPVT). We examined whether rPVT performance displays time-on-task effects similar to those observed on the hPVT. The rPVT requires rats to respond to a randomly presented light stimulus to obtain a water reward. Rats were water deprived for 22 h prior to each 30-min rPVT session to motivate performance. We analyzed rPVT performance over time on task and as a function of the response-stimulus interval, at baseline and after sleep deprivation. The study was conducted in an academic research vivarium. Male Long-Evans rats were trained to respond to a 0.5 sec stimulus light within 3 sec of stimulus onset. Complete data were available for n = 20 rats. Rats performed the rPVT for 30 min at baseline and after 24 h total sleep deprivation by gentle handling. Compared to baseline, sleep deprived rats displayed increased performance lapses and premature responses, similar to hPVT lapses of attention and false starts. However, in contrast to hPVT performance, the time-on-task performance decrement was not significantly enhanced by sleep deprivation. Moreover, following sleep deprivation, rPVT response times were not consistently increased after short response-stimulus intervals. The rPVT manifests similarities to the hPVT in global performance outcomes, but not in post-sleep deprivation effects of time on task and response-stimulus interval. © 2015 Associated Professional Sleep Societies, LLC.
Menumerov, Eredzhep; Hughes, Robert A; Neretina, Svetlana
2016-12-14
The reduction of 4-nitrophenol to 4-aminophenol by borohydride is one of the foremost model catalytic reactions because it allows for a straightforward assessment of catalysts using the kinetic parameters extracted from the real-time spectroscopic monitoring of an aqueous solution. Crucial to its standing as a model reaction is a comprehensive mechanistic framework able to explain the entire time evolution of the reaction. While much of this framework is in place, there is still much debate over the cause of the induction period, an initial time interval where no reaction seemingly occurs. Here, we report on the simultaneous monitoring of the spectroscopic signal and the dissolved oxygen content within the aqueous solution. It reveals that the induction period is the time interval required for the level of dissolved oxygen to fall below a critical value that is dependent upon whether Au, Ag, or Pd nanoparticles are used as the catalyst. With this understanding, we are able to exert complete control over the induction period, being able to eliminate it, extend it indefinitely, or even induce multiple induction periods over the course of a single reaction. Moreover, we have determined that the reaction product, 4-aminophenol, in the presence of the same catalyst reacts with dissolved oxygen to form 4-nitrophenolate. The implication of these results is that the induction period relates, not to some activation of the catalyst, but to a time interval where the reaction product is being rapidly transformed back into a reactant by a side reaction.
Not All Prehospital Time is Equal: Influence of Scene Time on Mortality
Brown, Joshua B.; Rosengart, Matthew R.; Forsythe, Raquel M.; Reynolds, Benjamin R.; Gestring, Mark L.; Hallinan, William M.; Peitzman, Andrew B.; Billiar, Timothy R.; Sperry, Jason L.
2016-01-01
Background Trauma is time-sensitive and minimizing prehospital (PH) time is appealing. However, most studies have not linked increasing PH time with worse outcomes, as raw PH times are highly variable. It is unclear whether specific PH time patterns affect outcomes. Our objective was to evaluate the association of PH time interval distribution with mortality. Methods Patients transported by EMS in the Pennsylvania trauma registry 2000-2013 with total prehospital time (TPT)≥20min were included. TPT was divided into three PH time intervals: response, scene, and transport time. The number of minutes in each PH time interval was divided by TPT to determine the relative proportion each interval contributed to TPT. A prolonged interval was defined as any one PH interval contributing ≥50% of TPT. Patients were classified by prolonged PH interval or no prolonged PH interval (all intervals<50% of TPT). Patients were matched for TPT and conditional logistic regression determined the association of mortality with PH time pattern, controlling for confounders. PH interventions were explored as potential mediators, and prehospital triage criteria used identify patients with time-sensitive injuries. Results There were 164,471 patients included. Patients with prolonged scene time had increased odds of mortality (OR 1.21; 95%CI 1.02–1.44, p=0.03). Prolonged response, transport, and no prolonged interval were not associated with mortality. When adjusting for mediators including extrication and PH intubation, prolonged scene time was no longer associated with mortality (OR 1.06; 0.90–1.25, p=0.50). Together these factors mediated 61% of the effect between prolonged scene time and mortality. Mortality remained associated with prolonged scene time in patients with hypotension, penetrating injury, and flail chest. Conclusions Prolonged scene time is associated with increased mortality. PH interventions partially mediate this association. Further study should evaluate whether these interventions drive increased mortality because they prolong scene time or by another mechanism, as reducing scene time may be a target for intervention. Level of Evidence IV, prognostic study PMID:26886000
Wrightwood and the earthquake cycle: What a long recurrence record tells us about how faults work
Weldon, R.; Scharer, K.; Fumal, T.; Biasi, G.
2004-01-01
The concept of the earthquake cycle is so well established that one often hears statements in the popular media like, "the Big One is overdue" and "the longer it waits, the bigger it will be." Surprisingly, data to critically test the variability in recurrence intervals, rupture displacements, and relationships between the two are almost nonexistent. To generate a long series of earthquake intervals and offsets, we have conducted paleoseismic investigations across the San Andreas fault near the town of Wrightwood, California, excavating 45 trenches over 18 years, and can now provide some answers to basic questions about recurrence behavior of large earthquakes. To date, we have characterized at least 30 prehistoric earthquakes in a 6000-yr-long record, complete for the past 1500 yr and for the interval 3000-1500 B.C. For the past 1500 yr, the mean recurrence interval is 105 yr (31-165 yr for individual intervals) and the mean slip is 3.2 m (0.7-7 m per event). The series is slightly more ordered than random and has a notable cluster of events, during which strain was released at 3 times the long-term average rate. Slip associated with an earthquake is not well predicted by the interval preceding it, and only the largest two earthquakes appear to affect the time interval to the next earthquake. Generally, short intervals tend to coincide with large displacements and long intervals with small displacements. The most significant correlation we find is that earthquakes are more frequent following periods of net strain accumulation spanning multiple seismic cycles. The extent of paleoearthquake ruptures may be inferred by correlating event ages between different sites along the San Andreas fault. Wrightwood and other nearby sites experience rupture that could be attributed to overlap of relatively independent segments that each behave in a more regular manner. However, the data are equally consistent with a model in which the irregular behavior seen at Wrightwood typifies the entire southern San Andreas fault; more long event series will be required to definitively outline prehistoric rupture extents.
Hepatitis A outbreak on a floating restaurant in Florida, 1986.
Lowry, P W; Levine, R; Stroup, D F; Gunn, R A; Wilder, M H; Konigsberg, C
1989-01-01
In April and May 1986, the largest reported foodborne outbreak of hepatitis A in Florida state history occurred among patrons and employees of a floating restaurant. A total of 103 cases (97 patrons and six employees) were identified. The exposure period lasted 31 days (March 20-April 19), making this the most prolonged hepatitis A outbreak to occur in a restaurant that to date has been reported to the Centers for Disease Control. The exposure period was divided into time intervals (peak, early, late, and total) for calculation of food-specific attack rates. The authors showed that green salad was an important vehicle of transmission for each phase of the exposure period, with the highest adjusted odds ratio for the three-day peak exposure interval (March 28-30), 6.8 (p = 0.001). Non-salad pantry items and mixed bar drinks were also identified as vehicles of transmission; both were more important during the early interval of the exposure period than during the late interval. Two of six infected employees worked in the pantry and may have sequentially infected patrons. Though rare, this outbreak suggests that hepatitis A infection among employees may allow for transmission to patrons for prolonged periods of time. Prevention of such outbreaks requires prompt reporting of ill patrons with rapid identification of infected employees and correction of food handling practices.
Lim, Y; Shah, M K; Tan, H M
2005-11-01
The Royal College of Obstetricians and Gynaecologists published the "Organisational Standards for Maternity Services" in 1995, in which they proposed that there be a maximum decision-to-delivery time of 30 minutes for urgent caesarean sections (CS). In 1997, our institution established a protocol for extremely urgent ("crash") CS to expedite delivery time and to conform to this standard. The objective of this prospective audit was to determine the surgical and anaesthesia response times in our institution after the protocol had been implemented. The audit was conducted in KK Women's and Children's Hospital from February 2003 to January 2004, over a 12-month period. Upon activation of a "crash" CS, the attending anaesthetist was required to record the decision-to-anaesthesia time, decision-to-delivery time and the perinatal outcome. Ninety-eight cases of "crash" CS were identified from a total of 3629 elective and non-elective CS, with 80 cases having complete data. The mean decision-to-delivery interval was 7.7 min+/-3.0 (SD) with 100% of deliveries made within 17 minutes. The mean decision-to-anaesthesia time was 3.5 min+/-2.0 (SD) with all the patients anaesthetised within 10 minutes. The majority (88.8%) of the patients had general anaesthesia for "crash" CS while the rest had successful epidural block extension. There was no significant difference in the decision-to-delivery interval or mean cord blood pH with respect to the type of anaesthesia given. We achieved 100% deliveries within the proposed 30-minute decision-to-delivery time interval by implementing a protocol for "crash" CS. Both general anaesthesia and extension of existing epidural block are acceptable modes of anaesthesia and do not delay delivery of the fetus.
Panek, Petr; Prochazka, Ivan
2007-09-01
This article deals with the time interval measurement device, which is based on a surface acoustic wave (SAW) filter as a time interpolator. The operating principle is based on the fact that a transversal SAW filter excited by a short pulse can generate a finite signal with highly suppressed spectra outside a narrow frequency band. If the responses to two excitations are sampled at clock ticks, they can be precisely reconstructed from a finite number of samples and then compared so as to determine the time interval between the two excitations. We have designed and constructed a two-channel time interval measurement device which allows independent timing of two events and evaluation of the time interval between them. The device has been constructed using commercially available components. The experimental results proved the concept. We have assessed the single-shot time interval measurement precision of 1.3 ps rms that corresponds to the time of arrival precision of 0.9 ps rms in each channel. The temperature drift of the measured time interval on temperature is lower than 0.5 ps/K, and the long term stability is better than +/-0.2 ps/h. These are to our knowledge the best values reported for the time interval measurement device. The results are in good agreement with the error budget based on the theoretical analysis.
Gissane, Conor; Hodgson, Lisa; Jennings, De
2012-09-01
To describe the injury rates in first team rugby league in terms of those injuries that require missed playing time and those that do not. A pooled data analysis from 2 independent databases. Rugby league match and training environment over several seasons from 1990 to 2003. Injuries were reported as rates per 1000 hours of participation and as percentages with their associated 95% confidence intervals (CIs). A total of 1707 match injuries were recorded. Of these injuries, 257 required players to miss the subsequent match. The remaining 1450 injuries did not require players to miss the next game. They represented 85% (95% CI, 83-87) of all injuries received and recorded. The ratio of non-time-loss (NTL) to time-loss (TL) injuries was 5.64 (95% CI, 4.96-6.42). There were 450 training injuries, of which 81 were TL injuries and 369 NTL injuries. The NTL training injury rate was 4.56 (95% CI, 3.58-5.79) times higher than TL injury rate. Non-time-loss injuries represent the largest proportion of injuries in rugby league. If NTL injuries are not recorded, the workload of practitioners is likely to be severely underestimated.
Payne, Thomas G.
1982-01-01
REGIONAL MAPPER is a menu-driven system in the BASIC language for computing and plotting (1) time, depth, and average velocity to geologic horizons, (2) interval time, thickness, and interval velocity of stratigraphic intervals, and (3) subcropping and onlapping intervals at unconformities. The system consists of three programs: FILER, TRAVERSER, and PLOTTER. A control point is a shot point with velocity analysis or a shot point at or near a well with velocity check-shot survey. Reflection time to and code number of seismic horizons are filed by digitizing tablet from record sections. TRAVERSER starts at a point of geologic control and, in traversing to another, parallels seismic events, records loss of horizons by onlap and truncation, and stores reflection time for geologic horizons at traversed shot points. TRAVERSER is basically a phantoming procedure. Permafrost thickness and velocity variations, buried canyons with low-velocity fill, and error in seismically derived velocity cause velocity anomalies that complicate depth mapping. Two depths to the top of the pebble is based shale are computed for each control point. One depth, designated Zs on seismically derived velocity. The other (Zw) is based on interval velocity interpolated linearly between wells and multiplied by interval time (isochron) to give interval thickness. Z w is computed for all geologic horizons by downward summation of interval thickness. Unknown true depth (Z) to the pebble shale may be expressed as Z = Zs + es and Z = Zw + ew where the e terms represent error. Equating the two expressions gives the depth difference D = Zs + Zw = ew + es A plot of D for the top of the pebble shale is readily contourable but smoothing is required to produce a reasonably simple surface. Seismically derived velocity used in computing Zs includes the effect of velocity anomalies but is subject to some large randomly distributed errors resulting in depth errors (es). Well-derived velocity used in computing Zw does not include the effect of velocity anomalies, but the error (ew) should reflect these anomalies and should be contourable (non-random). The D surface as contoured with smoothing is assumed to represent ew, that is, the depth effect of variations in permafrost thickness and velocity and buried canyon depth. Estimated depth (Zest) to each geologic horizon is the sum of Z w for that horizon and a constant e w as contoured for the pebble shale, which is the first highly continuous seismic horizon below the zone of anomalous velocity. Results of this 'depthing' procedure are compared with those of Tetra Tech, Inc., the subcontractor responsible for geologic and geophysical interpretation and mapping.
NASA Technical Reports Server (NTRS)
Chao, W. C.
1982-01-01
With appropriate modifications, a recently proposed explicit-multiple-time-step scheme (EMTSS) is incorporated into the UCLA model. In this scheme, the linearized terms in the governing equations that generate the gravity waves are split into different vertical modes. Each mode is integrated with an optimal time step, and at periodic intervals these modes are recombined. The other terms are integrated with a time step dictated by the CFL condition for low-frequency waves. This large time step requires a special modification of the advective terms in the polar region to maintain stability. Test runs for 72 h show that EMTSS is a stable, efficient and accurate scheme.
Temporal production and visuospatial processing.
Benuzzi, Francesca; Basso, Gianpaolo; Nichelli, Paolo
2005-12-01
Current models of prospective timing hypothesize that estimated duration is influenced either by the attentional load or by the short-term memory requirements of a concurrent nontemporal task. In the present study, we addressed this issue with four dual-task experiments. In Exp. 1, the effect of memory load on both reaction time and temporal production was proportional to the number of items of a visuospatial pattern to hold in memory. In Exps. 2, 3, and 4, a temporal production task was combined with two visual search tasks involving either pre-attentive or attentional processing. Visual tasks interfered with temporal production: produced intervals were lengthened proportionally to the display size. In contrast, reaction times increased with display size only when a serial, effortful search was required. It appears that memory and perceptual set size, rather than nonspecific attentional or short-term memory load, can influence prospective timing.
Interval Timing Accuracy and Scalar Timing in C57BL/6 Mice
Buhusi, Catalin V.; Aziz, Dyana; Winslow, David; Carter, Rickey E.; Swearingen, Joshua E.; Buhusi, Mona C.
2010-01-01
In many species, interval timing behavior is accurate—appropriate estimated durations—and scalar—errors vary linearly with estimated durations. While accuracy has been previously examined, scalar timing has not been yet clearly demonstrated in house mice (Mus musculus), raising concerns about mouse models of human disease. We estimated timing accuracy and precision in C57BL/6 mice, the most used background strain for genetic models of human disease, in a peak-interval procedure with multiple intervals. Both when timing two intervals (Experiment 1) or three intervals (Experiment 2), C57BL/6 mice demonstrated varying degrees of timing accuracy. Importantly, both at individual and group level, their precision varied linearly with the subjective estimated duration. Further evidence for scalar timing was obtained using an intraclass correlation statistic. This is the first report of consistent, reliable scalar timing in a sizable sample of house mice, thus validating the PI procedure as a valuable technique, the intraclass correlation statistic as a powerful test of the scalar property, and the C57BL/6 strain as a suitable background for behavioral investigations of genetically engineered mice modeling disorders of interval timing. PMID:19824777
Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek
2015-02-01
To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.
Adeli, Khosrow; Higgins, Victoria; Nieuwesteeg, Michelle; Raizman, Joshua E; Chen, Yunqi; Wong, Suzy L; Blais, David
2015-08-01
Defining laboratory biomarker reference values in a healthy population and understanding the fluctuations in biomarker concentrations throughout life and between sexes are critical to clinical interpretation of laboratory test results in different disease states. The Canadian Health Measures Survey (CHMS) has collected blood samples and health information from the Canadian household population. In collaboration with the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER), the data have been analyzed to determine reference value distributions and reference intervals for several endocrine and special chemistry biomarkers in pediatric, adult, and geriatric age groups. CHMS collected data and blood samples from thousands of community participants aged 3 to 79 years. We used serum samples to measure 13 immunoassay-based special chemistry and endocrine markers. We assessed reference value distributions and, after excluding outliers, calculated age- and sex-specific reference intervals, along with corresponding 90% CIs, according to CLSI C28-A3 guidelines. We observed fluctuations in biomarker reference values across the pediatric, adult, and geriatric age range, with stratification required on the basis of age for all analytes. Additional sex partitions were required for apolipoprotein AI, homocysteine, ferritin, and high sensitivity C-reactive protein. The unique collaboration between CALIPER and CHMS has enabled, for the first time, a detailed examination of the changes in various immunochemical markers that occur in healthy individuals of different ages. The robust age- and sex-specific reference intervals established in this study provide insight into the complex biological changes that take place throughout development and aging and will contribute to improved clinical test interpretation. © 2015 American Association for Clinical Chemistry.
VARIABLE TIME-INTERVAL GENERATOR
Gross, J.E.
1959-10-31
This patent relates to a pulse generator and more particularly to a time interval generator wherein the time interval between pulses is precisely determined. The variable time generator comprises two oscillators with one having a variable frequency output and the other a fixed frequency output. A frequency divider is connected to the variable oscillator for dividing its frequency by a selected factor and a counter is used for counting the periods of the fixed oscillator occurring during a cycle of the divided frequency of the variable oscillator. This defines the period of the variable oscillator in terms of that of the fixed oscillator. A circuit is provided for selecting as a time interval a predetermined number of periods of the variable oscillator. The output of the generator consists of a first pulse produced by a trigger circuit at the start of the time interval and a second pulse marking the end of the time interval produced by the same trigger circuit.
Time for actions in lucid dreams: effects of task modality, length, and complexity
Erlacher, Daniel; Schädlich, Melanie; Stumbrys, Tadas; Schredl, Michael
2014-01-01
The relationship between time in dreams and real time has intrigued scientists for centuries. The question if actions in dreams take the same time as in wakefulness can be tested by using lucid dreams where the dreamer is able to mark time intervals with prearranged eye movements that can be objectively identified in EOG recordings. Previous research showed an equivalence of time for counting in lucid dreams and in wakefulness (LaBerge, 1985; Erlacher and Schredl, 2004), but Erlacher and Schredl (2004) found that performing squats required about 40% more time in lucid dreams than in the waking state. To find out if the task modality, the task length, or the task complexity results in prolonged times in lucid dreams, an experiment with three different conditions was conducted. In the first condition, five proficient lucid dreamers spent one to three non-consecutive nights in the sleep laboratory. Participants counted to 10, 20, and 30 in wakefulness and in their lucid dreams. Lucidity and task intervals were time stamped with left-right-left-right eye movements. The same procedure was used for the second condition where eight lucid dreamers had to walk 10, 20, or 30 steps. In the third condition, eight lucid dreamers performed a gymnastics routine, which in the waking state lasted the same time as walking 10 steps. Again, we found that performing a motor task in a lucid dream requires more time than in wakefulness. Longer durations in the dream state were present for all three tasks, but significant differences were found only for the tasks with motor activity (walking and gymnastics). However, no difference was found for relative times (no disproportional time effects) and a more complex motor task did not result in more prolonged times. Longer durations in lucid dreams might be related to the lack of muscular feedback or slower neural processing during REM sleep. Future studies should explore factors that might be associated with prolonged durations. PMID:24474942
Time for actions in lucid dreams: effects of task modality, length, and complexity.
Erlacher, Daniel; Schädlich, Melanie; Stumbrys, Tadas; Schredl, Michael
2013-01-01
The relationship between time in dreams and real time has intrigued scientists for centuries. The question if actions in dreams take the same time as in wakefulness can be tested by using lucid dreams where the dreamer is able to mark time intervals with prearranged eye movements that can be objectively identified in EOG recordings. Previous research showed an equivalence of time for counting in lucid dreams and in wakefulness (LaBerge, 1985; Erlacher and Schredl, 2004), but Erlacher and Schredl (2004) found that performing squats required about 40% more time in lucid dreams than in the waking state. To find out if the task modality, the task length, or the task complexity results in prolonged times in lucid dreams, an experiment with three different conditions was conducted. In the first condition, five proficient lucid dreamers spent one to three non-consecutive nights in the sleep laboratory. Participants counted to 10, 20, and 30 in wakefulness and in their lucid dreams. Lucidity and task intervals were time stamped with left-right-left-right eye movements. The same procedure was used for the second condition where eight lucid dreamers had to walk 10, 20, or 30 steps. In the third condition, eight lucid dreamers performed a gymnastics routine, which in the waking state lasted the same time as walking 10 steps. Again, we found that performing a motor task in a lucid dream requires more time than in wakefulness. Longer durations in the dream state were present for all three tasks, but significant differences were found only for the tasks with motor activity (walking and gymnastics). However, no difference was found for relative times (no disproportional time effects) and a more complex motor task did not result in more prolonged times. Longer durations in lucid dreams might be related to the lack of muscular feedback or slower neural processing during REM sleep. Future studies should explore factors that might be associated with prolonged durations.
Measuring Skew in Average Surface Roughness as a Function of Surface Preparation
NASA Technical Reports Server (NTRS)
Stahl, Mark
2015-01-01
Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.
Parameter Transient Behavior Analysis on Fault Tolerant Control System
NASA Technical Reports Server (NTRS)
Belcastro, Christine (Technical Monitor); Shin, Jong-Yeob
2003-01-01
In a fault tolerant control (FTC) system, a parameter varying FTC law is reconfigured based on fault parameters estimated by fault detection and isolation (FDI) modules. FDI modules require some time to detect fault occurrences in aero-vehicle dynamics. This paper illustrates analysis of a FTC system based on estimated fault parameter transient behavior which may include false fault detections during a short time interval. Using Lyapunov function analysis, the upper bound of an induced-L2 norm of the FTC system performance is calculated as a function of a fault detection time and the exponential decay rate of the Lyapunov function.
Horn, W; Miksch, S; Egghart, G; Popow, C; Paky, F
1997-09-01
Real-time systems for monitoring and therapy planning, which receive their data from on-line monitoring equipment and computer-based patient records, require reliable data. Data validation has to utilize and combine a set of fast methods to detect, eliminate, and repair faulty data, which may lead to life-threatening conclusions. The strength of data validation results from the combination of numerical and knowledge-based methods applied to both continuously-assessed high-frequency data and discontinuously-assessed data. Dealing with high-frequency data, examining single measurements is not sufficient. It is essential to take into account the behavior of parameters over time. We present time-point-, time-interval-, and trend-based methods for validation and repair. These are complemented by time-independent methods for determining an overall reliability of measurements. The data validation benefits from the temporal data-abstraction process, which provides automatically derived qualitative values and patterns. The temporal abstraction is oriented on a context-sensitive and expectation-guided principle. Additional knowledge derived from domain experts forms an essential part for all of these methods. The methods are applied in the field of artificial ventilation of newborn infants. Examples from the real-time monitoring and therapy-planning system VIE-VENT illustrate the usefulness and effectiveness of the methods.
Brett, Benjamin L; Smyk, Nathan; Solomon, Gary; Baughman, Brandon C; Schatz, Philip
2016-08-18
The ImPACT (Immediate Post-Concussion Assessment and Cognitive Testing) neurocognitive testing battery is a widely used tool used for the assessment and management of sports-related concussion. Research on the stability of ImPACT in high school athletes at a 1- and 2-year intervals have been inconsistent, requiring further investigation. We documented 1-, 2-, and 3-year test-retest reliability of repeated ImPACT baseline assessments in a sample of high school athletes, using multiple statistical methods for examining stability. A total of 1,510 high school athletes completed baseline cognitive testing using online ImPACT test battery at three time periods of approximately 1- (N = 250), 2- (N = 1146), and 3-year (N = 114) intervals. No participant sustained a concussion between assessments. Intraclass correlation coefficients (ICCs) ranged in composite scores from 0.36 to 0.90 and showed little change as intervals between assessments increased. Reliable change indices and regression-based measures (RBMs) examining the test-retest stability demonstrated a lack of significant change in composite scores across the various time intervals, with very few cases (0%-6%) falling outside of 95% confidence intervals. The results suggest ImPACT composites scores remain considerably stability across 1-, 2-, and 3-year test-retest intervals in high school athletes, when considering both ICCs and RBM. Annually ascertaining baseline scores continues to be optimal for ensuring accurate and individualized management of injury for concussed athletes. For instances in which more recent baselines are not available (1-2 years), clinicians should seek to utilize more conservative range estimates in determining the presence of clinically meaningful change in cognitive performance. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Quantitative imaging biomarkers: Effect of sample size and bias on confidence interval coverage.
Obuchowski, Nancy A; Bullen, Jennifer
2017-01-01
Introduction Quantitative imaging biomarkers (QIBs) are being increasingly used in medical practice and clinical trials. An essential first step in the adoption of a quantitative imaging biomarker is the characterization of its technical performance, i.e. precision and bias, through one or more performance studies. Then, given the technical performance, a confidence interval for a new patient's true biomarker value can be constructed. Estimating bias and precision can be problematic because rarely are both estimated in the same study, precision studies are usually quite small, and bias cannot be measured when there is no reference standard. Methods A Monte Carlo simulation study was conducted to assess factors affecting nominal coverage of confidence intervals for a new patient's quantitative imaging biomarker measurement and for change in the quantitative imaging biomarker over time. Factors considered include sample size for estimating bias and precision, effect of fixed and non-proportional bias, clustered data, and absence of a reference standard. Results Technical performance studies of a quantitative imaging biomarker should include at least 35 test-retest subjects to estimate precision and 65 cases to estimate bias. Confidence intervals for a new patient's quantitative imaging biomarker measurement constructed under the no-bias assumption provide nominal coverage as long as the fixed bias is <12%. For confidence intervals of the true change over time, linearity must hold and the slope of the regression of the measurements vs. true values should be between 0.95 and 1.05. The regression slope can be assessed adequately as long as fixed multiples of the measurand can be generated. Even small non-proportional bias greatly reduces confidence interval coverage. Multiple lesions in the same subject can be treated as independent when estimating precision. Conclusion Technical performance studies of quantitative imaging biomarkers require moderate sample sizes in order to provide robust estimates of bias and precision for constructing confidence intervals for new patients. Assumptions of linearity and non-proportional bias should be assessed thoroughly.
Schweiger, Regev; Fisher, Eyal; Rahmani, Elior; Shenhav, Liat; Rosset, Saharon; Halperin, Eran
2018-06-22
Estimation of heritability is an important task in genetics. The use of linear mixed models (LMMs) to determine narrow-sense single-nucleotide polymorphism (SNP)-heritability and related quantities has received much recent attention, due of its ability to account for variants with small effect sizes. Typically, heritability estimation under LMMs uses the restricted maximum likelihood (REML) approach. The common way to report the uncertainty in REML estimation uses standard errors (SEs), which rely on asymptotic properties. However, these assumptions are often violated because of the bounded parameter space, statistical dependencies, and limited sample size, leading to biased estimates and inflated or deflated confidence intervals (CIs). In addition, for larger data sets (e.g., tens of thousands of individuals), the construction of SEs itself may require considerable time, as it requires expensive matrix inversions and multiplications. Here, we present FIESTA (Fast confidence IntErvals using STochastic Approximation), a method for constructing accurate CIs. FIESTA is based on parametric bootstrap sampling, and, therefore, avoids unjustified assumptions on the distribution of the heritability estimator. FIESTA uses stochastic approximation techniques, which accelerate the construction of CIs by several orders of magnitude, compared with previous approaches as well as to the analytical approximation used by SEs. FIESTA builds accurate CIs rapidly, for example, requiring only several seconds for data sets of tens of thousands of individuals, making FIESTA a very fast solution to the problem of building accurate CIs for heritability for all data set sizes.
Krall, Scott P; Cornelius, Angela P; Addison, J Bruce
2014-03-01
To analyze the correlation between the many different emergency department (ED) treatment metric intervals and determine if the metrics directly impacted by the physician correlate to the "door to room" interval in an ED (interval determined by ED bed availability). Our null hypothesis was that the cause of the variation in delay to receiving a room was multifactorial and does not correlate to any one metric interval. We collected daily interval averages from the ED information system, Meditech©. Patient flow metrics were collected on a 24-hour basis. We analyzed the relationship between the time intervals that make up an ED visit and the "arrival to room" interval using simple correlation (Pearson Correlation coefficients). Summary statistics of industry standard metrics were also done by dividing the intervals into 2 groups, based on the average ED length of stay (LOS) from the National Hospital Ambulatory Medical Care Survey: 2008 Emergency Department Summary. Simple correlation analysis showed that the doctor-to-discharge time interval had no correlation to the interval of "door to room (waiting room time)", correlation coefficient (CC) (CC=0.000, p=0.96). "Room to doctor" had a low correlation to "door to room" CC=0.143, while "decision to admitted patients departing the ED time" had a moderate correlation of 0.29 (p <0.001). "New arrivals" (daily patient census) had a strong correlation to longer "door to room" times, 0.657, p<0.001. The "door to discharge" times had a very strong correlation CC=0.804 (p<0.001), to the extended "door to room" time. Physician-dependent intervals had minimal correlation to the variation in arrival to room time. The "door to room" interval was a significant component to the variation in "door to discharge" i.e. LOS. The hospital-influenced "admit decision to hospital bed" i.e. hospital inpatient capacity, interval had a correlation to delayed "door to room" time. The other major factor affecting department bed availability was the "total patients per day." The correlation to the increasing "door to room" time also reflects the effect of availability of ED resources (beds) on the patient evaluation time. The time that it took for a patient to receive a room appeared more dependent on the system resources, for example, beds in the ED, as well as in the hospital, than on the physician.
NASA Technical Reports Server (NTRS)
Ali, Syed Firasat; Khan, M. Javed; Rossi, Marcia J.; Crane, Peter; Guckenberger, Dutch; Bageon, Kellye
2001-01-01
Above Real Time Training (ARTT) is the training acquired on a real time simulator when it is modified to present events at a faster pace than normal. The experiments on training of pilots performed by NASA engineers and others have indicated that real time training (RTT) reinforced with ARTT would offer an effective training strategy for such tasks which require significant effort at time and workload management. A study was conducted to find how ARTT and RTT complement each other for training of novice pilot-navigator teams to fly on a required route. In the experiment, each of the participating pilot-navigator teams was required to conduct simulator flights on a prescribed two-legged ground track while maintaining required air speed and altitude. At any instant in a flight, the distance between the actual spatial point location of the airplane and the required spatial point was used as a measure of deviation from the required route. A smaller deviation represented better performance. Over a segment of flight or over complete flight, an average value of the deviation represented consolidated performance. The deviations were computed from the information on latitude, longitude, and altitude. In the combined ARTT and RTT program, ARTT at intermediate training intervals was beneficial in improving the real time performance of the trainees. It was observed that the team interaction between pilot and navigator resulted in maintaining high motivation and active participation throughout the training program.
Intact interval timing in circadian CLOCK mutants.
Cordes, Sara; Gallistel, C R
2008-08-28
While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval-timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/- and -/- mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing.
The Anaesthetic-ECT Time Interval in Electroconvulsive Therapy Practice--Is It Time to Time?
Gálvez, Verònica; Hadzi-Pavlovic, Dusan; Wark, Harry; Harper, Simon; Leyden, John; Loo, Colleen K
2016-01-01
Because most common intravenous anaesthetics used in ECT have anticonvulsant properties, their plasma-brain concentration at the time of seizure induction might affect seizure expression. The quality of ECT seizure expression has been repeatedly associated with efficacy outcomes. The time interval between the anaesthetic bolus injection and the ECT stimulus (anaesthetic-ECT time interval) will determine the anaesthetic plasma-brain concentration when the ECT stimulus is administered. The aim of this study was to examine the effect of the anaesthetic-ECT time interval on ECT seizure quality and duration. The anaesthetic-ECT time interval was recorded in 771 ECT sessions (84 patients). Right unilateral brief pulse ECT was applied. Anaesthesia given was propofol (1-2 mg/kg) and succinylcholine (0.5-1.0 mg/kg). Seizure quality indices (slow wave onset, amplitude, regularity, stereotypy and post-ictal suppression) and duration were rated through a structured rating scale by a single blinded trained rater. Linear Mixed Effects Models analysed the effect of the anaesthetic-ECT time interval on seizure quality indices, controlling for propofol dose (mg), ECT charge (mC), ECT session number, days between ECT, age (years), initial seizure threshold (mC) and concurrent medication. Longer anaesthetic-ECT time intervals lead to significantly higher quality seizures (p < 0.001 for amplitude, regularity, stereotypy and post-ictal suppression). These results suggest that the anaesthetic-ECT time interval is an important factor to consider in ECT practice. This time interval should be extended to as long as practically possible to facilitate the production of better quality seizures. Close collaboration between the anaesthetist and the psychiatrist is essential. Copyright © 2015 Elsevier Inc. All rights reserved.
Trichinella spiralis: effect of high temperature on infectivity in pork.
Kotula, A W; Murrell, K D; Acosta-Stein, L; Lamb, L; Douglass, L
1983-08-01
Twenty gram samples of homogenized Boston shoulder from swine experimentally infected with Trichinella spiralis were sealed in plastic pouches, pressed to a uniform thickness of 2 mm, and subjected to water bath temperatures of 49, 52, 55, 60, and 63 +/- 0.5 C for intervals of 2 min to 6 hr, especially within the interval of 0 to 15 min. These times included a period of about 1 min at the start and a period of about 1 min at the end for temperature equilibration. Treated samples were rapidly chilled to 25 C and then digested in a 1% pepsin-HCl solution at 37 C for 18 hr to recover T. spiralis larvae. The recovered larvae were suspended in 2 ml saline; 1 ml of this suspension was introduced into the stomach of each of two rats. The linear equation, log (time) = 17.3 -0.302 (temperature), was calculated from the time required at each temperature for the inactivation of T. spiralis larvae. The correlation coefficient for that relationship was r = -0.994. Larvae heated in the meat to 55 C for 4 min retained their infectivity, but were rendered noninfective after 6 min at 55 C. At 60 C, larvae were not infective after only 2 min (zero dwell time); whereas at 52 C, 47 min were required to render the larvae noninfective. Larvae in meat heated to 49 C were infective after 5 hr but not after 6 hr. These data demonstrate that the destruction of infectivity of T. spiralis is time-temperature related.
Determination of the Time-Space Magnetic Correlation Functions in the Solar Wind
NASA Astrophysics Data System (ADS)
Weygand, J. M.; Matthaeus, W. H.; Kivelson, M.; Dasso, S.
2013-12-01
Magnetic field data from many different intervals and 7 different solar wind spacecraft are employed to estimate the scale-dependent time decorrelation function in the interplanetary magnetic field in both the slow and fast solar wind. This estimation requires correlations varying with both space and time lags. The two point correlation function with no time lag is determined by correlating time series data from multiple spacecraft separated in space and for complete coverage of length scales relies on many intervals with different spacecraft spatial separations. In addition we employ single spacecraft time-lagged correlations, and two spacecraft time lagged correlations to access different spatial and temporal correlation data. Combining these data sets gives estimates of the scale-dependent time decorrelation function, which in principle tells us how rapidly time decorrelation occurs at a given wavelength. For static fields the scale-dependent time decorrelation function is trivially unity, but in turbulence the nonlinear cascade process induces time-decorrelation at a given length scale that occurs more rapidly with decreasing scale. The scale-dependent time decorrelation function is valuable input to theories as well as various applications such as scattering, transport, and study of predictability. It is also a fundamental element of formal turbulence theory. Our results are extension of the Eulerian correlation functions estimated in Matthaeus et al. [2010], Weygand et al [2012; 2013].
Nixdorff, Uwe; Feddersen, Isa; Voigt, Jens-Uwe; Flachskampf, Frank A
2005-01-01
Three-dimensional echocardiography (3DE) improves the accuracy of left ventricle (LV) volumetry compared with the two-dimensional echocardiography (2DE) approach because geometric assumptions in the algorithms may be eliminated. The relationship between accuracy of mode (short- versus long-axis planimetry) and the number of component images versus time required for analysis remains to be determined. Sixteen latex models simulating heterogeneously distorted (aneurysmatic) human LVs (56-303 ml; mean 182+/-82 ml) were scanned from an 'apical' position (simultaneous 2DE and 3DE). For 3DE volumetry, the slice thickness was varied for the short (C-scan) and long axes (B-scan) in 5-mm steps between 1 and 25 mm. The mean differences (true-echocardiographic volumes) were 16.5+/-44.3 ml in the 2DE approach (95% confidence intervals -27.8 to +60.8) and 0.6+/-4.0 ml (short axis; 95% confidence intervals -3.4 to +4.6) as well as 2.1+/-9.9 ml (long axis; 95% confidence intervals -7.8 to +12.0) in the 3DE approach (in both cases, the slice thickness was 1 mm). Above a slice thickness of 15 mm, the 95% confidence intervals increased steeply; in the short versus long axes, these were -6.5 to +8.5 versus -7.0 to +10.6 at 15 mm and -10.1 to +15.7 versus -11.3 to +10.9 at 20 mm. The intra-observer variance differed significantly (p<0.001) only above 15 mm (short axis). Time required for analysis derived by measuring short-axis slice thicknesses of 1, 15, and 25 mm was 58+/-16, 7+/-2 and 3+/-1 min, respectively. The most rational component image analysis for 3DE volumetry in the in vitro model uses short-axis slices with a thickness of 15 mm. Copyright (c) 2005 S. Karger AG, Basel.
Scrutinio, Domenico; Lanzillo, Bernardo; Guida, Pietro; Mastropasqua, Filippo; Monitillo, Vincenzo; Pusineri, Monica; Formica, Roberto; Russo, Giovanna; Guarnaschelli, Caterina; Ferretti, Chiara; Calabrese, Gianluigi
2017-12-01
Prediction of outcome after stroke rehabilitation may help clinicians in decision-making and planning rehabilitation care. We developed and validated a predictive tool to estimate the probability of achieving improvement in physical functioning (model 1) and a level of independence requiring no more than supervision (model 2) after stroke rehabilitation. The models were derived from 717 patients admitted for stroke rehabilitation. We used multivariable logistic regression analysis to build each model. Then, each model was prospectively validated in 875 patients. Model 1 included age, time from stroke occurrence to rehabilitation admission, admission motor and cognitive Functional Independence Measure scores, and neglect. Model 2 included age, male gender, time since stroke onset, and admission motor and cognitive Functional Independence Measure score. Both models demonstrated excellent discrimination. In the derivation cohort, the area under the curve was 0.883 (95% confidence intervals, 0.858-0.910) for model 1 and 0.913 (95% confidence intervals, 0.884-0.942) for model 2. The Hosmer-Lemeshow χ 2 was 4.12 ( P =0.249) and 1.20 ( P =0.754), respectively. In the validation cohort, the area under the curve was 0.866 (95% confidence intervals, 0.840-0.892) for model 1 and 0.850 (95% confidence intervals, 0.815-0.885) for model 2. The Hosmer-Lemeshow χ 2 was 8.86 ( P =0.115) and 34.50 ( P =0.001), respectively. Both improvement in physical functioning (hazard ratios, 0.43; 0.25-0.71; P =0.001) and a level of independence requiring no more than supervision (hazard ratios, 0.32; 0.14-0.68; P =0.004) were independently associated with improved 4-year survival. A calculator is freely available for download at https://goo.gl/fEAp81. This study provides researchers and clinicians with an easy-to-use, accurate, and validated predictive tool for potential application in rehabilitation research and stroke management. © 2017 American Heart Association, Inc.
Empirical Model of the Location of the Main Ionospheric Trough
NASA Astrophysics Data System (ADS)
Deminov, M. G.; Shubin, V. N.
2018-05-01
The empirical model of the location of the main ionospheric trough (MIT) is developed based on an analysis of data from CHAMP satellite measured at the altitudes of 350-450 km during 2000-2007; the model is presented in the form of the analytical dependence of the invariant latitude of the trough minimum Φm on the magnetic local time (MLT), the geomagnetic activity, and the geographical longitude for the Northern and Southern Hemispheres. The time-weighted average index Kp(τ), the coefficient of which τ = 0.6 is determined by the requirement of the model minimum deviation from experimental data, is used as an indicator of geomagnetic activity. The model has no limitations, either in local time or geomagnetic activity. However, the initial set of MIT minima mainly contains data dealing with an interval of 16-08 MLT for Kp(τ) < 6; therefore, the model is rather qualitative outside this interval. It is also established that (a) the use of solar local time (SLT) instead of MLT increases the model error no more than by 5-10%; (b) the amplitude of the longitudinal effect at the latitude of MIT minimum in geomagnetic (invariant) coordinates is ten times lower than that in geographical coordinates.
González-García, Nadia; González, Martha A; Rendón, Pablo L
2016-07-15
Relationships between musical pitches are described as either consonant, when associated with a pleasant and harmonious sensation, or dissonant, when associated with an inharmonious feeling. The accurate singing of musical intervals requires communication between auditory feedback processing and vocal motor control (i.e. audio-vocal integration) to ensure that each note is produced correctly. The objective of this study is to investigate the neural mechanisms through which trained musicians produce consonant and dissonant intervals. We utilized 4 musical intervals (specifically, an octave, a major seventh, a fifth, and a tritone) as the main stimuli for auditory discrimination testing, and we used the same interval tasks to assess vocal accuracy in a group of musicians (11 subjects, all female vocal students at conservatory level). The intervals were chosen so as to test for differences in recognition and production of consonant and dissonant intervals, as well as narrow and wide intervals. The subjects were studied using fMRI during performance of the interval tasks; the control condition consisted of passive listening. Singing dissonant intervals as opposed to singing consonant intervals led to an increase in activation in several regions, most notably the primary auditory cortex, the primary somatosensory cortex, the amygdala, the left putamen, and the right insula. Singing wide intervals as opposed to singing narrow intervals resulted in the activation of the right anterior insula. Moreover, we also observed a correlation between singing in tune and brain activity in the premotor cortex, and a positive correlation between training and activation of primary somatosensory cortex, primary motor cortex, and premotor cortex during singing. When singing dissonant intervals, a higher degree of training correlated with the right thalamus and the left putamen. Our results indicate that singing dissonant intervals requires greater involvement of neural mechanisms associated with integrating external feedback from auditory and sensorimotor systems than singing consonant intervals, and it would then seem likely that dissonant intervals are intoned by adjusting the neural mechanisms used for the production of consonant intervals. Singing wide intervals requires a greater degree of control than singing narrow intervals, as it involves neural mechanisms which again involve the integration of internal and external feedback. Copyright © 2016 Elsevier B.V. All rights reserved.
Sleep Deprivation and Time-on-Task Performance Decrement in the Rat Psychomotor Vigilance Task
Oonk, Marcella; Davis, Christopher J.; Krueger, James M.; Wisor, Jonathan P.; Van Dongen, Hans P.A.
2015-01-01
Study Objectives: The rat psychomotor vigilance task (rPVT) was developed as a rodent analog of the human psychomotor vigilance task (hPVT). We examined whether rPVT performance displays time-on-task effects similar to those observed on the hPVT. Design: The rPVT requires rats to respond to a randomly presented light stimulus to obtain a water reward. Rats were water deprived for 22 h prior to each 30-min rPVT session to motivate performance. We analyzed rPVT performance over time on task and as a function of the response-stimulus interval, at baseline and after sleep deprivation. Setting: The study was conducted in an academic research vivarium. Participants: Male Long-Evans rats were trained to respond to a 0.5 sec stimulus light within 3 sec of stimulus onset. Complete data were available for n = 20 rats. Interventions: Rats performed the rPVT for 30 min at baseline and after 24 h total sleep deprivation by gentle handling. Measurements and Results: Compared to baseline, sleep deprived rats displayed increased performance lapses and premature responses, similar to hPVT lapses of attention and false starts. However, in contrast to hPVT performance, the time-on-task performance decrement was not significantly enhanced by sleep deprivation. Moreover, following sleep deprivation, rPVT response times were not consistently increased after short response-stimulus intervals. Conclusions: The rat psychomotor vigilance task manifests similarities to the human psychomotor vigilance task in global performance outcomes, but not in post-sleep deprivation effects of time on task and response-stimulus interval. Citation: Oonk M, Davis CJ, Krueger JM, Wisor JP, Van Dongen HPA. Sleep deprivation and time-on-task performance decrement in the rat psychomotor vigilance task. SLEEP 2015;38(3):445–451. PMID:25515099
Cardiopulmonary resuscitation quality: Widespread variation in data intervals used for analysis.
Talikowska, Milena; Tohira, Hideo; Bailey, Paul; Finn, Judith
2016-05-01
There is a growing body of evidence for the relationship between CPR quality and survival in cardiac arrest patients. We sought to describe the characteristics of the analysis intervals used across studies. Relevant papers were selected as described in our recent systematic review. From these papers we collected information about (1) the time interval used for analysis; (2) the event that marked the beginning of the analysis interval; and (3) the minimum amount of CPR quality data required for a case to be included in the analysed cohort. We then compared this data across papers. Twenty-one studies reported on the association between CPR quality and cardiac arrest patient survival. In two thirds of studies data from the start of the resuscitation episode was analysed, in particular the first 5min. Commencement of the analysis interval was marked by various events including ECG pad placement and first chest compression. Nine studies specified a minimum amount of data that had to have been collected for the individual case to be included in the analysis; most commonly 1min of data. The use of shorter intervals allowed for inclusion of more cases as it included cases that did not have a complete dataset. To facilitate comparisons across studies, a standardised definition of the data analysis interval should be developed; one that maximises the amount of cases available without compromising the data's representability of the resuscitation effort. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Metoclopramide: an analgesic adjunct to patient-controlled analgesia.
Rosenblatt, W H; Cioffi, A M; Sinatra, R; Saberski, L R; Silverman, D G
1991-11-01
This randomized, double-blind trial evaluated the effect of metoclopramide on the pain and analgesic requirements associated with prostaglandin-induced labor for second-trimester termination of pregnancy. After receiving intrauterine prostaglandin, seven women were given intravenous metoclopramide (10 mg), and eight received saline, concurrent with initiation of patient controlled analgesia (PCA). Group differences were assessed with serial visual analogue scale for pain, interval PCA-morphine consumption, and time to fetal delivery. The metoclopramide group used 54% less PCA morphine (24.1 vs 52.0 mg), had lower visual analogue scale scores, and interval morphine consumption at 2, 4, and 6 h after PCA had been initiated, as well as earlier delivery of the fetus when compared with the control group (P less than 0.05). We conclude that a single dose of metoclopramide reduces the pain and PCA-morphine requirements of patients undergoing prostaglandin-induced labor and may facilitate passage of the fetus. Metoclopramide may have a similar application in treating other types of gynecologic pain.
Flight Crew Responses to the Interval Management Alternative Clearances (IMAC) Experiment
NASA Technical Reports Server (NTRS)
Baxley, Brian T.; Wilson, Sara R.; Swieringa, Kurt A.; Roper, Roy D.
2016-01-01
Interval Management Alternative Clearances (IMAC) was a human-in-the-loop simulation experiment conducted to explore the efficacy and acceptability of three IM operations: CAPTURE, CROSS, and MAINTAIN. Two weeks of data collection were conducted, with each week using twelve subject pilots and four subject controllers flying ten high-density arrival scenarios into the Denver International Airport. Overall, both the IM operations and procedures were rated very favorably by the flight crew in terms of acceptability, workload, and pilot head down time. However, several critical issues were identified requiring resolution prior to real-world implementation, including the high frequency of IM speed commands, IM speed commands requiring changes to aircraft configuration, and ambiguous IM cockpit displays that did not trigger the intended pilot reaction. The results from this experiment will be used to prepare for a flight test in 2017, and to support the development of an advanced IM concept of operations by the FAA (Federal Aviation Agency) and aviation industry.
Steerable dyadic wavelet transform and interval wavelets for enhancement of digital mammography
NASA Astrophysics Data System (ADS)
Laine, Andrew F.; Koren, Iztok; Yang, Wuhai; Taylor, Fred J.
1995-04-01
This paper describes two approaches for accomplishing interactive feature analysis by overcomplete multiresolution representations. We show quantitatively that transform coefficients, modified by an adaptive non-linear operator, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. Our results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. We design a filter bank representing a steerable dyadic wavelet transform that can be used for multiresolution analysis along arbitrary orientations. Digital mammograms are enhanced by orientation analysis performed by a steerable dyadic wavelet transform. Arbitrary regions of interest (ROI) are enhanced by Deslauriers-Dubuc interpolation representations on an interval. We demonstrate that our methods can provide radiologists with an interactive capability to support localized processing of selected (suspicion) areas (lesions). Features extracted from multiscale representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology can improve changes of early detection while requiring less time to evaluate mammograms for most patients.
Intact Interval Timing in Circadian CLOCK Mutants
Cordes, Sara; Gallistel, C. R.
2008-01-01
While progress has been made in determining the molecular basis for the circadian clock, the mechanism by which mammalian brains time intervals measured in seconds to minutes remains a mystery. An obvious question is whether the interval timing mechanism shares molecular machinery with the circadian timing mechanism. In the current study, we trained circadian CLOCK +/− and −/− mutant male mice in a peak-interval procedure with 10 and 20-s criteria. The mutant mice were more active than their wild-type littermates, but there were no reliable deficits in the accuracy or precision of their timing as compared with wild-type littermates. This suggests that expression of the CLOCK protein is not necessary for normal interval timing. PMID:18602902
The impact of brief high-intensity exercise on blood glucose levels.
Adams, O Peter
2013-01-01
Moderate-intensity exercise improves blood glucose (BG), but most people fail to achieve the required exercise volume. High-intensity exercise (HIE) protocols vary. Maximal cycle ergometer sprint interval training typically requires only 2.5 minutes of HIE and a total training time commitment (including rest and warm up) of 25 minutes per session. The effect of brief high-intensity exercise on blood glucose levels of people with and without diabetes is reviewed. HIE (≥80% maximal oxygen uptake, VO2max) studies with ≤15 minutes HIE per session were reviewed. Six studies of nondiabetics (51 males, 14 females) requiring 7.5 to 20 minutes/week of HIE are reviewed. Two weeks of sprint interval training increased insulin sensitivity up to 3 days postintervention. Twelve weeks near maximal interval running (total exercise time 40 minutes/week) improved BG to a similar extent as running at 65% VO2max for 150 minutes/week. Eight studies of diabetics (41 type 1 and 22 type 2 subjects) were reviewed. Six were of a single exercise session with 44 seconds to 13 minutes of HIE, and the others were 2 and 7 weeks duration with 20 and 2 minutes/week HIE, respectively. With type 1 and 2 diabetes, BG was generally higher during and up to 2 hours after HIE compared to controls. With type 1 diabetics, BG decreased from midnight to 6 AM following HIE the previous morning. With type 2 diabetes, a single session improved postprandial BG for 24 hours, while a 2-week program reduced the average BG by 13% at 48 to 72 hours after exercise and also increased GLUT4 by 369%. Very brief HIE improves BG 1 to 3 days postexercise in both diabetics and non-diabetics. HIE is unlikely to cause hypoglycemia during and immediately after exercise. Larger and longer randomized studies are needed to determine the safety, acceptability, long-term efficacy, and optimal exercise intensity and duration.
Versyck, Barbara; van Geffen, Geert-Jan; Van Houwe, Patrick
2017-08-01
The aim of this clinical trial was to test the hypothesis whether adding the pectoral nerves (Pecs) block type II to the anesthetic procedure reduces opioid consumption during and after breast surgery. A prospective randomized double blind placebo-controlled study. A secondary hospital. 140 breast cancer stage 1-3 patients undergoing mastectomy or tumorectomy with sentinel node or axillary node dissection. Patients were randomized to receive either a Pecs block with levobupivacaine 0.25% (n=70) or placebo block with saline (n=70). The pain levels were evaluated by Numeric Rating Scale (NRS) pain scores at 15-minute intervals during the post anesthesia care unit stay time (PACU), at 2-hour intervals for the first 24h on the ward and at 4-hour intervals for the next 24h. Intraoperative and postoperative opioid consumption were recorded during the full stay. Patient satisfaction was evaluated upon discharge using a 10-point scale. Intraoperative sufentanil requirements were comparable for the Pecs and placebo group (8.0±3.5μg and 7.8±3.0μg, P=0.730). Patients in the Pecs group experienced significantly less pain than patients in the control group (P=0.048) during their PACU stay. Furthermore, patients in the Pecs group required significant less postoperative opioids (9.16±10.15mg and 14.97±14.38mg morphine equivalent, P=0.037) and required significant fewer postsurgical opioid administration interventions than patients in the control group (P=0.045). Both patient-groups were very satisfied about their management (9.6±0.6 and 9.1±1.8 on a 10-point scale, P=0.211). The Pecs block reduces postsurgical opioid consumption during the PACU stay time for patients undergoing breast surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Personalized glucose-insulin model based on signal analysis.
Goede, Simon L; de Galan, Bastiaan E; Leow, Melvin Khee Shing
2017-04-21
Glucose plasma measurements for diabetes patients are generally presented as a glucose concentration-time profile with 15-60min time scale intervals. This limited resolution obscures detailed dynamic events of glucose appearance and metabolism. Measurement intervals of 15min or more could contribute to imperfections in present diabetes treatment. High resolution data from mixed meal tolerance tests (MMTT) for 24 type 1 and type 2 diabetes patients were used in our present modeling. We introduce a model based on the physiological properties of transport, storage and utilization. This logistic approach follows the principles of electrical network analysis and signal processing theory. The method mimics the physiological equivalent of the glucose homeostasis comprising the meal ingestion, absorption via the gastrointestinal tract (GIT) to the endocrine nexus between the liver, pancreatic alpha and beta cells. This model demystifies the metabolic 'black box' by enabling in silico simulations and fitting of individual responses to clinical data. Five-minute intervals MMTT data measured from diabetic subjects result in two independent model parameters that characterize the complete glucose system response at a personalized level. From the individual data measurements, we obtain a model which can be analyzed with a standard electrical network simulator for diagnostics and treatment optimization. The insulin dosing time scale can be accurately adjusted to match the individual requirements of characterized diabetic patients without the physical burden of treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Working times of elastomeric impression materials determined by dimensional accuracy.
Tan, E; Chai, J; Wozniak, W T
1996-01-01
The working times of five poly(vinyl siloxane) impression materials were estimated by evaluating the dimensional accuracy of stone dies of impressions of a standard model made at successive time intervals. The stainless steel standard model was represented by two abutments having known distances between landmarks in three dimensions. Three dimensions in the x-, y-, and z-axes of the stone dies were measured with a traveling microscope. A time interval was rejected as being within the working time if the percentage change of the resultant dies, in any dimension, was statistically different from those measured from stone dies from previous time intervals. The absolute dimensions of those dies from the rejected time interval also must have exceeded all those from previous time intervals. Results showed that the working times estimated with this method generally were about 30 seconds longer than those recommended by the manufacturers.
Single-channel autocorrelation functions: the effects of time interval omission.
Ball, F G; Sansom, M S
1988-01-01
We present a general mathematical framework for analyzing the dynamic aspects of single channel kinetics incorporating time interval omission. An algorithm for computing model autocorrelation functions, incorporating time interval omission, is described. We show, under quite general conditions, that the form of these autocorrelations is identical to that which would be obtained if time interval omission was absent. We also show, again under quite general conditions, that zero correlations are necessarily a consequence of the underlying gating mechanism and not an artefact of time interval omission. The theory is illustrated by a numerical study of an allosteric model for the gating mechanism of the locust muscle glutamate receptor-channel. PMID:2455553
CALCULATION OF NONLINEAR CONFIDENCE AND PREDICTION INTERVALS FOR GROUND-WATER FLOW MODELS.
Cooley, Richard L.; Vecchia, Aldo V.
1987-01-01
A method is derived to efficiently compute nonlinear confidence and prediction intervals on any function of parameters derived as output from a mathematical model of a physical system. The method is applied to the problem of obtaining confidence and prediction intervals for manually-calibrated ground-water flow models. To obtain confidence and prediction intervals resulting from uncertainties in parameters, the calibrated model and information on extreme ranges and ordering of the model parameters within one or more independent groups are required. If random errors in the dependent variable are present in addition to uncertainties in parameters, then calculation of prediction intervals also requires information on the extreme range of error expected. A simple Monte Carlo method is used to compute the quantiles necessary to establish probability levels for the confidence and prediction intervals. Application of the method to a hypothetical example showed that inclusion of random errors in the dependent variable in addition to uncertainties in parameters can considerably widen the prediction intervals.
Communication: Coordinate-dependent diffusivity from single molecule trajectories
NASA Astrophysics Data System (ADS)
Berezhkovskii, Alexander M.; Makarov, Dmitrii E.
2017-11-01
Single-molecule observations of biomolecular folding are commonly interpreted using the model of one-dimensional diffusion along a reaction coordinate, with a coordinate-independent diffusion coefficient. Recent analysis, however, suggests that more general models are required to account for single-molecule measurements performed with high temporal resolution. Here, we consider one such generalization: a model where the diffusion coefficient can be an arbitrary function of the reaction coordinate. Assuming Brownian dynamics along this coordinate, we derive an exact expression for the coordinate-dependent diffusivity in terms of the splitting probability within an arbitrarily chosen interval and the mean transition path time between the interval boundaries. This formula can be used to estimate the effective diffusion coefficient along a reaction coordinate directly from single-molecule trajectories.
Simplified Interval Observer Scheme: A New Approach for Fault Diagnosis in Instruments
Martínez-Sibaja, Albino; Astorga-Zaragoza, Carlos M.; Alvarado-Lassman, Alejandro; Posada-Gómez, Rubén; Aguila-Rodríguez, Gerardo; Rodríguez-Jarquin, José P.; Adam-Medina, Manuel
2011-01-01
There are different schemes based on observers to detect and isolate faults in dynamic processes. In the case of fault diagnosis in instruments (FDI) there are different diagnosis schemes based on the number of observers: the Simplified Observer Scheme (SOS) only requires one observer, uses all the inputs and only one output, detecting faults in one detector; the Dedicated Observer Scheme (DOS), which again uses all the inputs and just one output, but this time there is a bank of observers capable of locating multiple faults in sensors, and the Generalized Observer Scheme (GOS) which involves a reduced bank of observers, where each observer uses all the inputs and m-1 outputs, and allows the localization of unique faults. This work proposes a new scheme named Simplified Interval Observer SIOS-FDI, which does not requires the measurement of any input and just with just one output allows the detection of unique faults in sensors and because it does not require any input, it simplifies in an important way the diagnosis of faults in processes in which it is difficult to measure all the inputs, as in the case of biologic reactors. PMID:22346593
Ultra-short heart rate variability recording reliability: The effect of controlled paced breathing.
Melo, Hiago M; Martins, Thiago C; Nascimento, Lucas M; Hoeller, Alexandre A; Walz, Roger; Takase, Emílio
2018-06-04
Recent studies have reported that Heart Rate Variability (HRV) indices remain reliable even during recordings shorter than 5 min, suggesting the ultra-short recording method as a valuable tool for autonomic assessment. However, the minimum time-epoch to obtain a reliable record for all HRV domains (time, frequency, and Poincare geometric measures), as well as the effect of respiratory rate on the reliability of these indices remains unknown. Twenty volunteers had their HRV recorded in a seated position during spontaneous and controlled respiratory rhythms. HRV intervals with 1, 2, and 3 min were correlated with the gold standard period (6-min duration) and the mean values of all indices were compared in the two respiratory rhythm conditions. rMSSD and SD1 were more reliable for recordings with ultra-short duration at all time intervals (r values from 0.764 to 0.950, p < 0.05) for spontaneous breathing condition, whereas the other indices require longer recording time to obtain reliable values. The controlled breathing rhythm evokes stronger r values for time domain indices (r values from 0.83 to 0.99, p < 0.05 for rMSSD), but impairs the mean values replicability of domains across most time intervals. Although the use of standardized breathing increases the correlations coefficients, all HRV indices showed an increase in mean values (t values from 3.79 to 14.94, p < 0.001) except the RR and HF that presented a decrease (t = 4.14 and 5.96, p < 0.0001). Our results indicate that proper ultra-short-term recording method can provide a quick and reliable source of cardiac autonomic nervous system assessment. © 2018 Wiley Periodicals, Inc.
Flight Deck Data Link Displays: An Evaluation of Textual and Graphical Implementations
NASA Technical Reports Server (NTRS)
McGann, Alison; Lozito, Sandy; Corker, Kevin; Ashford, Rose (Technical Monitor)
2001-01-01
In Experiment 1, 16 pilots participated in a part-task simulation study that evaluated pilot data link communication for short and long message types and for two textual formats. No differences were found between the two textual formats when evaluating data link transaction times and pilot performance on a secondary task. Pilots initiated flight changes more quickly with the T-Scan format, where location of clearance information roughly corresponded to the cockpit instrument layout. Longer messages were less problematic than two short messages sent in close succession as pilots required more verbal clarification for closely spaced messages. 24 pilots participated in a second experiment that evaluated pilot communication performance for textual data link, two implementations of graphical data link, and a combined graphical and textual information modality. The two modalities incorporating text resulted in significantly faster transaction times and better performance on the secondary task than the two graphical-only implementations. The interval between messages was also more systematically varied in Experiment 2, and a short interval between messages significantly increased the access time for the second message. This delay in access was long enough to increase significantly the total transaction time of the second message, and this effect was exaggerated for the graphical-only implementations. Time to view the message before acknowledgement and time to initiate flight changes were not affected by the interval manipulation, This suggests that pilots adopt a sequential message handling strategy, and presenting messages closely in succession may present operational problems in a data link Air Traffic Control (ATC) environment. The results of this study also indicate that the perceived importance of message content is currently a crucial element in pilot data link communication.
Zheng, Guanglou; Fang, Gengfa; Shankaran, Rajan; Orgun, Mehmet A; Zhou, Jie; Qiao, Li; Saleem, Kashif
2017-05-01
Generating random binary sequences (BSes) is a fundamental requirement in cryptography. A BS is a sequence of N bits, and each bit has a value of 0 or 1. For securing sensors within wireless body area networks (WBANs), electrocardiogram (ECG)-based BS generation methods have been widely investigated in which interpulse intervals (IPIs) from each heartbeat cycle are processed to produce BSes. Using these IPI-based methods to generate a 128-bit BS in real time normally takes around half a minute. In order to improve the time efficiency of such methods, this paper presents an ECG multiple fiducial-points based binary sequence generation (MFBSG) algorithm. The technique of discrete wavelet transforms is employed to detect arrival time of these fiducial points, such as P, Q, R, S, and T peaks. Time intervals between them, including RR, RQ, RS, RP, and RT intervals, are then calculated based on this arrival time, and are used as ECG features to generate random BSes with low latency. According to our analysis on real ECG data, these ECG feature values exhibit the property of randomness and, thus, can be utilized to generate random BSes. Compared with the schemes that solely rely on IPIs to generate BSes, this MFBSG algorithm uses five feature values from one heart beat cycle, and can be up to five times faster than the solely IPI-based methods. So, it achieves a design goal of low latency. According to our analysis, the complexity of the algorithm is comparable to that of fast Fourier transforms. These randomly generated ECG BSes can be used as security keys for encryption or authentication in a WBAN system.
Ripamonti, Giancarlo; Abba, Andrea; Geraci, Angelo
2010-05-01
A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.
Evaluation of SAMe-TT2R2 Score on Predicting Success With Extended-Interval Warfarin Monitoring.
Hwang, Andrew Y; Carris, Nicholas W; Dietrich, Eric A; Gums, John G; Smith, Steven M
2018-06-01
In patients with stable international normalized ratios, 12-week extended-interval warfarin monitoring can be considered; however, predictors of success with this strategy are unknown. The previously validated SAMe-TT 2 R 2 score (considering sex, age, medical history, treatment, tobacco, and race) predicts anticoagulation control during standard follow-up (every 4 weeks), with lower scores associated with greater time in therapeutic range. To evaluate the ability of the SAMe-TT 2 R 2 score in predicting success with extended-interval warfarin follow-up in patients with previously stable warfarin doses. In this post hoc analysis of a single-arm feasibility study, baseline SAMe-TT 2 R 2 scores were calculated for patients with ≥1 extended-interval follow-up visit. The primary analysis assessed achieved weeks of extended-interval follow-up according to baseline SAMe-TT 2 R 2 scores. A total of 47 patients receiving chronic anticoagulation completed a median of 36 weeks of extended-interval follow-up. The median baseline SAMe-TT 2 R 2 score was 1 (range 0-5). Lower SAMe-TT 2 R 2 scores appeared to be associated with greater duration of extended-interval follow-up achieved, though the differences between scores were not statistically significant. No individual variable of the SAMe-TT 2 R 2 score was associated with achieved weeks of extended-interval follow-up. Analysis of additional patient factors found that longer duration (≥24 weeks) of prior stable treatment was significantly associated with greater weeks of extended-interval follow-up completed ( P = 0.04). Conclusion and Relevance: This pilot study provides limited evidence that the SAMe-TT 2 R 2 score predicts success with extended-interval warfarin follow-up but requires confirmation in a larger study. Further research is also necessary to establish additional predictors of successful extended-interval warfarin follow-up.
Non-Markovianity of Gaussian Channels.
Torre, G; Roga, W; Illuminati, F
2015-08-14
We introduce a necessary and sufficient criterion for the non-Markovianity of Gaussian quantum dynamical maps based on the violation of divisibility. The criterion is derived by defining a general vectorial representation of the covariance matrix which is then exploited to determine the condition for the complete positivity of partial maps associated with arbitrary time intervals. Such construction does not rely on the Choi-Jamiolkowski representation and does not require optimization over states.
González-García, Nadia; Rendón, Pablo L
2017-05-23
The neural correlates of consonance and dissonance perception have been widely studied, but not the neural correlates of consonance and dissonance production. The most straightforward manner of musical production is singing, but, from an imaging perspective, it still presents more challenges than listening because it involves motor activity. The accurate singing of musical intervals requires integration between auditory feedback processing and vocal motor control in order to correctly produce each note. This protocol presents a method that permits the monitoring of neural activations associated with the vocal production of consonant and dissonant intervals. Four musical intervals, two consonant and two dissonant, are used as stimuli, both for an auditory discrimination test and a task that involves first listening to and then reproducing given intervals. Participants, all female vocal students at the conservatory level, were studied using functional Magnetic Resonance Imaging (fMRI) during the performance of the singing task, with the listening task serving as a control condition. In this manner, the activity of both the motor and auditory systems was observed, and a measure of vocal accuracy during the singing task was also obtained. Thus, the protocol can also be used to track activations associated with singing different types of intervals or with singing the required notes more accurately. The results indicate that singing dissonant intervals requires greater participation of the neural mechanisms responsible for the integration of external feedback from the auditory and sensorimotor systems than does singing consonant intervals.
Rest Intervals Reduce the Number of Loading Bouts Required to Enhance Bone Formation
Srinivasan, Sundar; Ausk, Brandon J.; Bain, Steven D.; Gardiner, Edith M.; Kwon, Ronald Y.; Gross, Ted S.
2015-01-01
Purpose As our society becomes increasingly sedentary, compliance with exercise regimens that require numerous high-energy activities each week become less likely. Alternatively, given an osteogenic exercise intervention that required minimal effort, it is reasonable to presume that participation would be enhanced. Insertion of brief rest-intervals between each cycle of mechanical loading holds potential to achieve this result as substantial osteoblast function is activated by many fewer loading repetitions within each loading bout. Here, we examined the complementary hypothesis that the number of bouts/wk of rest-inserted loading could be reduced from 3/wk without loss of osteogenic efficacy. Methods We conducted a series of 3 wk in vivo experiments that non-invasively exposed the right tibiae of mice to either cyclic (1 Hz) or rest-inserted loading interventions and quantified osteoblast function via dynamic histomorphometry. Results While reducing loading bouts from 3/wk (i.e., 9 total bouts) to 1/wk (3 total bouts) effectively mitigated the osteogenic benefit of cyclic loading, the same reduction did not significantly reduce periosteal bone formation parameters induced by rest-inserted loading. The osteogenic response was robust to the timing of the rest-inserted loading bouts (3 bouts in the first week vs 1 bout/wk for three weeks). However, elimination of any single bout of the three 1/wk bouts mitigated the osteogenic response to rest-inserted loading. Finally, periosteal osteoblast function assessed after the 3 wk intervention was not sensitive to the timing or number of rest-inserted loading bouts. Conclusions We conclude that rest-inserted loading holds potential to retain the osteogenic benefits of mechanical loading with significantly reduced frequency of bouts of activity while also enabling greater flexibility in the timing of the activity. PMID:25207932
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
... 11-1954] Local Number Portability Porting Interval and Validation Requirements; Telephone Number... information when the new service provider requests a CSR: any working telephone number associated with the...://www.fcc.gov/cgb/ecfs . For detailed instructions for submitting comments and additional information on...
Development of two-framing camera with large format and ultrahigh speed
NASA Astrophysics Data System (ADS)
Jiang, Xiaoguo; Wang, Yuan; Wang, Yi
2012-10-01
High-speed imaging facility is important and necessary for the formation of time-resolved measurement system with multi-framing capability. The framing camera which satisfies the demands of both high speed and large format needs to be specially developed in the ultrahigh speed research field. A two-framing camera system with high sensitivity and time-resolution has been developed and used for the diagnosis of electron beam parameters of Dragon-I linear induction accelerator (LIA). The camera system, which adopts the principle of light beam splitting in the image space behind the lens with long focus length, mainly consists of lens-coupled gated image intensifier, CCD camera and high-speed shutter trigger device based on the programmable integrated circuit. The fastest gating time is about 3 ns, and the interval time between the two frames can be adjusted discretely at the step of 0.5 ns. Both the gating time and the interval time can be tuned to the maximum value of about 1 s independently. Two images with the size of 1024×1024 for each can be captured simultaneously in our developed camera. Besides, this camera system possesses a good linearity, uniform spatial response and an equivalent background illumination as low as 5 electrons/pix/sec, which fully meets the measurement requirements of Dragon-I LIA.
Variations in rupture process with recurrence interval in a repeated small earthquake
Vidale, J.E.; Ellsworth, W.L.; Cole, A.; Marone, Chris
1994-01-01
In theory and in laboratory experiments, friction on sliding surfaces such as rock, glass and metal increases with time since the previous episode of slip. This time dependence is a central pillar of the friction laws widely used to model earthquake phenomena. On natural faults, other properties, such as rupture velocity, porosity and fluid pressure, may also vary with the recurrence interval. Eighteen repetitions of the same small earthquake, separated by intervals ranging from a few days to several years, allow us to test these laboratory predictions in situ. The events with the longest time since the previous earthquake tend to have about 15% larger seismic moment than those with the shortest intervals, although this trend is weak. In addition, the rupture durations of the events with the longest recurrence intervals are more than a factor of two shorter than for the events with the shortest intervals. Both decreased duration and increased friction are consistent with progressive fault healing during the time of stationary contact.In theory and in laboratory experiments, friction on sliding surfaces such as rock, glass and metal increases with time since the previous episode of slip. This time dependence is a central pillar of the friction laws widely used to model earthquake phenomena. On natural faults, other properties, such as rupture velocity, porosity and fluid pressure, may also vary with the recurrence interval. Eighteen repetitions of the same small earthquake, separated by intervals ranging from a few days to several years, allow us to test these laboratory predictions in situ. The events with the longest time since the previous earthquake tend to have about 15% larger seismic moment than those with the shortest intervals, although this trend is weak. In addition, the rupture durations of the events with the longest recurrence intervals are more than a factor of two shorter than for the events with the shortest intervals. Both decreased duration and increased friction are consistent with progressive fault healing during the time of stationary contact.
Mahajan, Neerja; Naveen, Y. G.; Sethuraman, Rajesh
2017-01-01
Introduction Acrylic based soft liners are cost effective, yet are inferior in durability as compared to silicone based liners. Hence, this study was conducted to evaluate if the softness and surface integrity of acrylic based soft liner can be maintained by using different surface treatment agents. Aim To comparatively evaluate the effects of Varnish, Monopoly and Kregard surface treatment agents on the surface integrity and softness of acrylic based soft liner at baseline, at one month and after three months. Materials and Methods A total of 37 participants who required conventional maxillary dentures were selected according to the determined inclusion and exclusion criteria of the study. In the maxillary denture on the denture bearing surface, eight palatal recesses (5 mm x 3 mm) were made and filled with acrylic based soft liner (Permasoft). The soft liners in these recesses were given surface treatment and divided as control (uncoated), Varnish, Monopoly and Kregard groups. The hardness and surface integrity were evaluated with Shore A Durometer and Scanning Electron Microscope (SEM) respectively at baseline, one month and three months interval. Surface integrity between groups was compared using Kruskal-Wallis test. Intergroup comparison for hardness was done using ANOVA and Tukey’s HSD post-hoc tests. Results Amongst all the groups tested, surface integrity was maintained in the Kregard group, as compared to control, Varnish and Monopoly groups for all three time intervals (p< 0.001). Kregard treated samples also demonstrated significantly higher softness at all the time intervals (p<0.001). Conclusion Surface treatment with Kregard demonstrated better surface integrity and softness at all the time intervals. PMID:29207842
Bye, Robin T; Neilson, Peter D
2010-10-01
Physiological tremor during movement is characterized by ∼10 Hz oscillation observed both in the electromyogram activity and in the velocity profile. We propose that this particular rhythm occurs as the direct consequence of a movement response planning system that acts as an intermittent predictive controller operating at discrete intervals of ∼100 ms. The BUMP model of response planning describes such a system. It forms the kernel of Adaptive Model Theory which defines, in computational terms, a basic unit of motor production or BUMP. Each BUMP consists of three processes: (1) analyzing sensory information, (2) planning a desired optimal response, and (3) execution of that response. These processes operate in parallel across successive sequential BUMPs. The response planning process requires a discrete-time interval in which to generate a minimum acceleration trajectory to connect the actual response with the predicted future state of the target and compensate for executional error. We have shown previously that a response planning time of 100 ms accounts for the intermittency observed experimentally in visual tracking studies and for the psychological refractory period observed in double stimulation reaction time studies. We have also shown that simulations of aimed movement, using this same planning interval, reproduce experimentally observed speed-accuracy tradeoffs and movement velocity profiles. Here we show, by means of a simulation study of constant velocity tracking movements, that employing a 100 ms planning interval closely reproduces the measurement discontinuities and power spectra of electromyograms, joint-angles, and angular velocities of physiological tremor reported experimentally. We conclude that intermittent predictive control through sequential operation of BUMPs is a fundamental mechanism of 10 Hz physiological tremor in movement. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleijnen, J; Asselen, B van; Burbach, M
2015-06-15
Purpose: Purpose of this study is to find the optimal trade-off between adaptation interval and margin reduction and to define the implications of motion for rectal cancer boost radiotherapy on a MR-linac. Methods: Daily MRI scans were acquired of 16 patients, diagnosed with rectal cancer, prior to each radiotherapy fraction in one week (N=76). Each scan session consisted of T2-weighted and three 2D sagittal cine-MRI, at begin (t=0 min), middle (t=9:30 min) and end (t=18:00 min) of scan session, for 1 minute at 2 Hz temporal resolution. Tumor and clinical target volume (CTV) were delineated on each T2-weighted scan andmore » transferred to each cine-MRI. The start frame of the begin scan was used as reference and registered to frames at time-points 15, 30 and 60 seconds, 9:30 and 18:00 minutes and 1, 2, 3 and 4 days later. Per time-point, motion of delineated voxels was evaluated using the deformation vector fields of the registrations and the 95th percentile distance (dist95%) was calculated as measure of motion. Per time-point, the distance that includes 90% of all cases was taken as estimate of required planning target volume (PTV)-margin. Results: Highest motion reduction is observed going from 9:30 minutes to 60 seconds. We observe a reduction in margin estimates from 10.6 to 2.7 mm and 16.1 to 4.6 mm for tumor and CTV, respectively, when adapting every 60 seconds compared to not adapting treatment. A 75% and 71% reduction, respectively. Further reduction in adaptation time-interval yields only marginal motion reduction. For adaptation intervals longer than 18:00 minutes only small motion reductions are observed. Conclusion: The optimal adaptation interval for adaptive rectal cancer (boost) treatments on a MR-linac is 60 seconds. This results in substantial smaller PTV-margin estimates. Adaptation intervals of 18:00 minutes and higher, show little improvement in motion reduction.« less
Buffered coscheduling for parallel programming and enhanced fault tolerance
Petrini, Fabrizio [Los Alamos, NM; Feng, Wu-chun [Los Alamos, NM
2006-01-31
A computer implemented method schedules processor jobs on a network of parallel machine processors or distributed system processors. Control information communications generated by each process performed by each processor during a defined time interval is accumulated in buffers, where adjacent time intervals are separated by strobe intervals for a global exchange of control information. A global exchange of the control information communications at the end of each defined time interval is performed during an intervening strobe interval so that each processor is informed by all of the other processors of the number of incoming jobs to be received by each processor in a subsequent time interval. The buffered coscheduling method of this invention also enhances the fault tolerance of a network of parallel machine processors or distributed system processors
Effects of learning with explicit elaboration on implicit transfer of visuomotor sequence learning.
Tanaka, Kanji; Watanabe, Katsumi
2013-08-01
Intervals between stimuli and/or responses have significant influences on sequential learning. In the present study, we investigated whether transfer would occur even when the intervals and the visual configurations in a sequence were drastically changed so that participants did not notice that the required sequences of responses were identical. In the experiment, two (or three) sequential button presses comprised a "set," and nine (or six) consecutive sets comprised a "hyperset." In the first session, participants learned either a 2 × 9 or 3 × 6 hyperset by trial and error until they completed it 20 times without error. In the second block, the 2 × 9 (3 × 6) hyperset was changed into the 3 × 6 (2 × 9) hyperset, resulting in different visual configurations and intervals between stimuli and responses. Participants were assigned into two groups: the Identical and Random groups. In the Identical group, the sequence (i.e., the buttons to be pressed) in the second block was identical to that in the first block. In the Random group, a new hyperset was learned. Even in the Identical group, no participants noticed that the sequences were identical. Nevertheless, a significant transfer of performance occurred. However, in the subsequent experiment that did not require explicit trial-and-error learning in the first session, implicit transfer in the second session did not occur. These results indicate that learning with explicit elaboration strengthens the implicit representation of the sequence order as a whole; this might occur independently of the intervals between elements and enable implicit transfer.
Colonoscopy Screening in the US Astronaut Corps
NASA Technical Reports Server (NTRS)
Masterova, K.; Van Baalen, M.; Wear, M. L.; Murray, J.; Schaefer, C.
2016-01-01
BACKGROUND: Historically, colonoscopy screenings for astronauts have been conducted to ensure that astronauts are in good health for space missions. Recently this historical data has been identified as being useful for developing an occupational surveillance requirement. It can be used to assess overall colon health and to have a point of reference for future tests in current and former astronauts, as well as to follow-up and track rates of colorectal cancer and polyps. These rates can be compared to military and other terrestrial populations. In 2003, the active astronaut colonoscopy requirements changed to require less frequent colonoscopies. Since polyp removal during a colonoscopy is an intervention that prevents the polyp from potentially developing into cancer, the procedure decreases the individual's risk for colon cancer. The objective of this study is to evaluate the possible effect of increased follow-up times between colonoscopies on the number and severity of polyps identified during the procedures among both current and former NASA astronauts. Initial results and forward work regarding astronaut colonoscopy screenings will be presented. METHODS: A retrospective study of all colonoscopy procedures performed on NASA astronauts between 1962 and 2015 (both during active career and retirement) was conducted by review of the JSC Clinic Electronic Medical Record and Lifetime Surveillance of Astronaut Health (LSAH) database for colonoscopy screening procedures and pathology reports. The timeframe of interest was from the time of selection into the Astronaut Corps through May 2015 or death. For each colonoscopy report, the following data were captured: date of procedure, age at time of procedure, reason for procedure, quality of bowel prep, completion of procedure and/or reason for termination of procedure, findings of procedure, subsequent treatment (if any), recommended follow-up interval, actual follow up interval, family history of polyps or colon cancer, and other significant items or discrepancies. The population consisted of 338 astronauts: 52 females, 286 males. Of these, 56 were deceased, and 11 astronauts had no record of any colonoscopies. Because of a screening requirement change in 2003, analyses were conducted to determine if there were differences between the two time periods. One-sided Wilcoxon rank sum tests were used to identify statistically significant differences between the two time periods. RESULTS: There was a combined total of 1,964 colonoscopy screenings identified. The average follow-up intervals between colonoscopies were indeed longer after the screening requirement change than before the change. The mean follow-up interval pre -2003 was 3.59 years, while post-2003 it increased to 4.35 years. The statistical significance of this difference was confirmed using a one sided Wilcoxon rank sum test which yielded p<.001. Colonoscopies performed after the requirement change tended to have a higher incidence and greater severity of polyps. From pre-2003 to post-2003 the percentage of colonoscopy procedures yielding no polyps decreased from 83.77% to 74.70%. Not only did post-2003 procedures yield more polyp findings, but the polyps recorded were more often of severe pathology. Before 2003 3.62% of colonoscopy findings were polyps of the hyperplastic type (the least severe polyp type) and only 3.35% were of greater severity. Post-2003, 4.21% of findings were hyperplastic polyps while 11.44% were of greater severity. Upon the investigation of other possible contributing factors to these results, we also found that mean age post-2003 was 54.55 years which was significantly higher than during the pre-2003 timeframe (47.32 years). This was observed with a one-sided Wilcoxon rank sum test, resulting in a p<0.001. The increased average age of astronauts could also be a contributing factor to the greater number of polyps found since the risk of developing polyps increases with age. Further work is needed to better understand the increased incidence and greater severity of polyps found in astronaut colonoscopy outcomes.
Identifying Significant Changes in Cerebrovascular Reactivity to Carbon Dioxide.
Sobczyk, O; Crawley, A P; Poublanc, J; Sam, K; Mandell, D M; Mikulis, D J; Duffin, J; Fisher, J A
2016-05-01
Changes in cerebrovascular reactivity can be used to assess disease progression and response to therapy but require discrimination of pathology from normal test-to-test variability. Such variability is due to variations in methodology, technology, and physiology with time. With uniform test conditions, our aim was to determine the test-to-test variability of cerebrovascular reactivity in healthy subjects and in patients with known cerebrovascular disease. Cerebrovascular reactivity was the ratio of the blood oxygen level-dependent MR imaging response divided by the change in carbon dioxide stimulus. Two standardized cerebrovascular reactivity tests were conducted at 3T in 15 healthy men (36.7 ± 16.1 years of age) within a 4-month period and were coregistered into standard space to yield voxelwise mean cerebrovascular reactivity interval difference measures, composing a reference interval difference atlas. Cerebrovascular reactivity interval difference maps were prepared for 11 male patients. For each patient, the test-retest difference of each voxel was scored statistically as z-values of the corresponding voxel mean difference in the reference atlas and then color-coded and superimposed on the anatomic images to create cerebrovascular reactivity interval difference z-maps. There were no significant test-to-test differences in cerebrovascular reactivity in either gray or white matter (mean gray matter, P = .431; mean white matter, P = .857; paired t test) in the healthy cohort. The patient cerebrovascular reactivity interval difference z-maps indicated regions where cerebrovascular reactivity increased or decreased and the probability that the changes were significant. Accounting for normal test-to-test differences in cerebrovascular reactivity enables the assessment of significant changes in disease status (stability, progression, or regression) in patients with time. © 2016 by American Journal of Neuroradiology.
Identification of bearing faults using time domain zero-crossings
NASA Astrophysics Data System (ADS)
William, P. E.; Hoffman, M. W.
2011-11-01
In this paper, zero-crossing characteristic features are employed for early detection and identification of single point bearing defects in rotating machinery. As a result of bearing defects, characteristic defect frequencies appear in the machine vibration signal, normally requiring spectral analysis or envelope analysis to identify the defect type. Zero-crossing features are extracted directly from the time domain vibration signal using only the duration between successive zero-crossing intervals and do not require estimation of the rotational frequency. The features are a time domain representation of the composite vibration signature in the spectral domain. Features are normalized by the length of the observation window and classification is performed using a multilayer feedforward neural network. The model was evaluated on vibration data recorded using an accelerometer mounted on an induction motor housing subjected to a number of single point defects with different severity levels.
Measuring skew in average surface roughness as a function of surface preparation
NASA Astrophysics Data System (ADS)
Stahl, Mark T.
2015-08-01
Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces polishing time, saves money and allows the science requirements to be better defined. This study characterized statistics of average surface roughness as a function of polishing time. Average surface roughness was measured at 81 locations using a Zygo® white light interferometer at regular intervals during the polishing process. Each data set was fit to a normal and Largest Extreme Value (LEV) distribution; then tested for goodness of fit. We show that the skew in the average data changes as a function of polishing time.
An automatic 14-day paste diet feeder for animals
NASA Technical Reports Server (NTRS)
Vasques, Marilyn; Mulenburg, Jerry; Gundo, Dan; Griffith, Jon
1994-01-01
During a centrifuge experiment, any interruption that requires stopping the centrifuge may influence the results. Centrifuges often must be stopped for animal maintenance (food, water and waste removal), especially in cases of timed feedings. To eliminate the need for stopping the centrifuge while still providing timed feeding, an automatic paste diet feeder was developed. The feeder is based on a constant volume concept and can deliver a predetermined amount of paste diet at specified time intervals. This unit was supported by water delivery and waste collection systems. The entire system performed reliably and maintained the animals well for a continuous centrifugation experiment of 14 days.
Propagating Qualitative Values Through Quantitative Equations
NASA Technical Reports Server (NTRS)
Kulkarni, Deepak
1992-01-01
In most practical problems where traditional numeric simulation is not adequate, one need to reason about a system with both qualitative and quantitative equations. In this paper, we address the problem of propagating qualitative values represented as interval values through quantitative equations. Previous research has produced exponential-time algorithms for approximate solution of the problem. These may not meet the stringent requirements of many real time applications. This paper advances the state of art by producing a linear-time algorithm that can propagate a qualitative value through a class of complex quantitative equations exactly and through arbitrary algebraic expressions approximately. The algorithm was found applicable to Space Shuttle Reaction Control System model.
Evidence against decay in verbal working memory.
Oberauer, Klaus; Lewandowsky, Stephan
2013-05-01
The article tests the assumption that forgetting in working memory for verbal materials is caused by time-based decay, using the complex-span paradigm. Participants encoded 6 letters for serial recall; each letter was preceded and followed by a processing period comprising 4 trials of difficult visual search. Processing duration, during which memory could decay, was manipulated via search set size. This manipulation increased retention interval by up to 100% without having any effect on recall accuracy. This result held with and without articulatory suppression. Two experiments using a dual-task paradigm showed that the visual search process required central attention. Thus, even when memory maintenance by central attention and by articulatory rehearsal was prevented, a large delay had no effect on memory performance, contrary to the decay notion. Most previous experiments that manipulated the retention interval and the opportunity for maintenance processes in complex span have confounded these variables with time pressure during processing periods. Three further experiments identified time pressure as the variable that affected recall. We conclude that time-based decay does not contribute to the capacity limit of verbal working memory. PsycINFO Database Record (c) 2013 APA, all rights reserved.
NASA Technical Reports Server (NTRS)
Rundle, John B.
1988-01-01
The idea that earthquakes represent a fluctuation about the long-term motion of plates is expressed mathematically through the fluctuation hypothesis, under which all physical quantities which pertain to the occurance of earthquakes are required to depend on the difference between the present state of slip on the fault and its long-term average. It is shown that under certain circumstances the model fault dynamics undergo a sudden transition from a spatially ordered, temporally disordered state to a spatially disordered, temporally ordered state, and that the latter stages are stable for long intervals of time. For long enough faults, the dynamics are evidently chaotic. The methods developed are then used to construct a detailed model for earthquake dynamics in southern California. The result is a set of slip-time histories for all the major faults, which are similar to data obtained by geological trenching studies. Although there is an element of periodicity to the events, the patterns shift, change and evolve with time. Time scales for pattern evolution seem to be of the order of a thousand years for average recurring intervals of about a hundred years.
de Menezes, Fernanda Souza; Leite, Heitor Pons; Nogueira, Paulo Cesar Koch
2013-01-01
Children admitted to the intensive care unit (ICU) are at risk of inadequate energy intake. Although studies have identified factors contributing to an inadequate energy supply in critically ill children, they did not take into consideration the length of time during which patients received their estimated energy requirements after having achieved a satisfactory energy intake. This study aimed to identify factors associated with the non-attainment of estimated energy requirements and consider the time this energy intake is maintained. This was a prospective study involving 207 children hospitalized in the ICU who were receiving enteral and/or parenteral nutrition. The outcome variable studied was whether 90% of the estimated basal metabolic rate was maintained for at least half of the ICU stay (satisfactory energy intake). The exposure variables for outcome were gender, age, diagnosis, use of vasopressors, malnutrition, route of nutritional support, and Pediatric Index of Mortality and Pediatric Logistic Organ Dysfunction scores. Satisfactory energy intake was attained by 20.8% of the patients, within a mean time of 5.07 ± 2.48 d. In a multivariable analysis, a diagnosis of heart disease (odds ratio 3.62, 95% confidence interval 1.03-12.68, P = 0.045) increased the risk of insufficient energy intake, whereas malnutrition (odds ratio 0.43, 95% confidence interval 0.20-0.92, P = 0.030) and the use of parenteral nutrition (odds ratio 0.34, 95% confidence interval 0.15-0.77, P = 0.001) were protective factors against this outcome. A satisfactory energy intake was reached by a small proportion of patients during their ICU stay. Heart disease was an independent risk factor for the non-attainment of satisfactory energy intake, whereas malnutrition and the use of parenteral nutrition were protective factors against this outcome. Copyright © 2013 Elsevier Inc. All rights reserved.
Single step optimization of manipulator maneuvers with variable structure control
NASA Technical Reports Server (NTRS)
Chen, N.; Dwyer, T. A. W., III
1987-01-01
One step ahead optimization has been recently proposed for spacecraft attitude maneuvers as well as for robot manipulator maneuvers. Such a technique yields a discrete time control algorithm implementable as a sequence of state-dependent, quadratic programming problems for acceleration optimization. Its sensitivity to model accuracy, for the required inversion of the system dynamics, is shown in this paper to be alleviated by a fast variable structure control correction, acting between the sampling intervals of the slow one step ahead discrete time acceleration command generation algorithm. The slow and fast looping concept chosen follows that recently proposed for optimal aiming strategies with variable structure control. Accelerations required by the VSC correction are reserved during the slow one step ahead command generation so that the ability to overshoot the sliding surface is guaranteed.
Faber, V.
1994-11-29
Livelock-free message routing is provided in a network of interconnected nodes that is flushable in time T. An input message processor generates sequences of at least N time intervals, each of duration T. An input register provides for receiving and holding each input message, where the message is assigned a priority state p during an nth one of the N time intervals. At each of the network nodes a message processor reads the assigned priority state and awards priority to messages with priority state (p-1) during an nth time interval and to messages with priority state p during an (n+1) th time interval. The messages that are awarded priority are output on an output path toward the addressed output message processor. Thus, no message remains in the network for a time longer than T. 4 figures.
Faber, Vance
1994-01-01
Livelock-free message routing is provided in a network of interconnected nodes that is flushable in time T. An input message processor generates sequences of at least N time intervals, each of duration T. An input register provides for receiving and holding each input message, where the message is assigned a priority state p during an nth one of the N time intervals. At each of the network nodes a message processor reads the assigned priority state and awards priority to messages with priority state (p-1) during an nth time interval and to messages with priority state p during an (n+1) th time interval. The messages that are awarded priority are output on an output path toward the addressed output message processor. Thus, no message remains in the network for a time longer than T.
Choice with a fixed requirement for food, and the generality of the matching relation
Stubbs, D. Alan; Dreyfus, Leon R.; Fetterman, J. Gregor; Dorman, Lana G.
1986-01-01
Pigeons were trained on choice procedures in which responses on each of two keys were reinforced probabilistically, but only after a schedule requirement had been met. Under one arrangement, a fixed-interval choice procedure was used in which responses were not reinforced until the interval was over; then a response on one key would be reinforced, with the effective key changing irregularly from interval to interval. Under a second, fixed-ratio choice procedure, responses on either key counted towards completion of the ratio and then, once the ratio had been completed, a response on the probabilistically selected key would produce food. In one experiment, the schedule requirements were varied for both fixed-interval and fixed-ratio schedules. In the second experiment, relative reinforcement rate was varied. And in a third experiment, the duration of an intertrial interval separating choices was varied. The results for 11 pigeons across all three experiments indicate that there were often large deviations between relative response rates and relative reinforcement rates. Overall performance measures were characterized by a great deal of variability across conditions. More detailed measures of choice across the schedule requirement were also quite variable across conditions. In spite of this variability, performance was consistent across conditions in its efficiency of producing food. The absence of matching of behavior allocation to reinforcement rate indicates an important difference between the present procedures and other choice procedures; that difference raises questions about the specific conditions that lead to matching as an outcome. PMID:16812452
Thiazolidinediones and Parkinson Disease: A Cohort Study.
Connolly, John G; Bykov, Katsiaryna; Gagne, Joshua J
2015-12-01
Thiazolidinediones, a class of medications indicated for the treatment of type 2 diabetes mellitus, reduce inflammation and have been shown to provide a therapeutic benefit in animal models of Parkinson disease. We examined the association between treatment with thiazolidinediones and the onset of Parkinson disease in older individuals. We performed a cohort study of 29,397 Medicare patients enrolled in state pharmaceutical benefits programs who initiated treatment with thiazolidinediones or sulfonylureas during the years 1997 through 2005 and had no prior diagnosis of Parkinson disease. New users of thiazolidinediones were propensity score matched to new users of sulfonylureas and followed to determine whether they were diagnosed with Parkinson disease. We used Cox proportional hazards models to compare time to diagnosis of Parkinson disease in the propensity score-matched populations. To assess the association with duration of use, we performed several analyses that required longer continuous use of medications. In the primary analysis, thiazolidinedione users had a hazard ratio for a diagnosis of Parkinson disease of 1.09 (95% confidence interval: 0.71, 1.66) when compared with sulfonylurea users. Increasing the duration-of-use requirements to 10 months did not substantially change the association; the hazard ratios ranged from 1.00 (95% confidence interval: 0.49, 2.05) to 1.17 (95% confidence interval: 0.60, 2.25). Thiazolidinedione use was not associated with a longer time to diagnosis of Parkinson disease than was sulfonylurea use, regardless of duration of exposure. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Simpson, Colin R; Steiner, Markus Fc; Cezard, Genevieve; Bansal, Narinder; Fischbacher, Colin; Douglas, Anne; Bhopal, Raj; Sheikh, Aziz
2015-10-01
There is evidence of substantial ethnic variations in asthma morbidity and the risk of hospitalisation, but the picture in relation to lower respiratory tract infections is unclear. We carried out an observational study to identify ethnic group differences for lower respiratory tract infections. A retrospective, cohort study. Scotland. 4.65 million people on whom information was available from the 2001 census, followed from May 2001 to April 2010. Hospitalisations and deaths (any time following first hospitalisation) from lower respiratory tract infections, adjusted risk ratios and hazard ratios by ethnicity and sex were calculated. We multiplied ratios and confidence intervals by 100, so the reference Scottish White population's risk ratio and hazard ratio was 100. Among men, adjusted risk ratios for lower respiratory tract infection hospitalisation were lower in Other White British (80, 95% confidence interval 73-86) and Chinese (69, 95% confidence interval 56-84) populations and higher in Pakistani groups (152, 95% confidence interval 136-169). In women, results were mostly similar to those in men (e.g. Chinese 68, 95% confidence interval 56-82), although higher adjusted risk ratios were found among women of the Other South Asians group (145, 95% confidence interval 120-175). Survival (adjusted hazard ratio) following lower respiratory tract infection for Pakistani men (54, 95% confidence interval 39-74) and women (31, 95% confidence interval 18-53) was better than the reference population. Substantial differences in the rates of lower respiratory tract infections amongst different ethnic groups in Scotland were found. Pakistani men and women had particularly high rates of lower respiratory tract infection hospitalisation. The reasons behind the high rates of lower respiratory tract infection in the Pakistani community are now required. © The Royal Society of Medicine.
Lambert, Ronald J W; Mytilinaios, Ioannis; Maitland, Luke; Brown, Angus M
2012-08-01
This study describes a method to obtain parameter confidence intervals from the fitting of non-linear functions to experimental data, using the SOLVER and Analysis ToolPaK Add-In of the Microsoft Excel spreadsheet. Previously we have shown that Excel can fit complex multiple functions to biological data, obtaining values equivalent to those returned by more specialized statistical or mathematical software. However, a disadvantage of using the Excel method was the inability to return confidence intervals for the computed parameters or the correlations between them. Using a simple Monte-Carlo procedure within the Excel spreadsheet (without recourse to programming), SOLVER can provide parameter estimates (up to 200 at a time) for multiple 'virtual' data sets, from which the required confidence intervals and correlation coefficients can be obtained. The general utility of the method is exemplified by applying it to the analysis of the growth of Listeria monocytogenes, the growth inhibition of Pseudomonas aeruginosa by chlorhexidine and the further analysis of the electrophysiological data from the compound action potential of the rodent optic nerve. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Effect of time delay on surgical performance during telesurgical manipulation.
Fabrizio, M D; Lee, B R; Chan, D Y; Stoianovici, D; Jarrett, T W; Yang, C; Kavoussi, L R
2000-03-01
Telementoring allows a less experienced surgeon to benefit from an expert surgical consultation, reducing cost, travel, and the learning curve associated with new procedures. However, there are several technical limitations that affect practical applications. One potentially serious problem is the time delay that occurs any time data are transferred across long distances. To date, the effect of time delay on surgical performance has not been studied. A two-phase trial was designed to examine the effect of time delay on surgical performance. In the first phase, a series of tasks was performed, and the numbers of robotic movements required for completion was counted. Programmed incremental time delays were made in audiovisual acquisition and robotic controls. The number of errors made while performing each task at various time delay intervals was noted. In the second phase, a remote surgeon in Baltimore performed the tasks 9000 miles away in Singapore. The number of errors made was recorded. As the time delay increased, the number of operator errors increased. The accuracy needed to perform remote robotic procedures was diminished as the time delay increased. A learning curve did exist for each task, but as the time delay interval increased, it took longer to complete the task. Time delay does affect surgical performance. There is an acceptable delay of <700 msec in which surgeons can compensate for this phenomenon. Clinical studies will be needed to evaluate the true impact of time delay.
User's manual for THPLOT, A FORTRAN 77 Computer program for time history plotting
NASA Technical Reports Server (NTRS)
Murray, J. E.
1982-01-01
A general purpose FORTRAN 77 computer program (THPLOT) for plotting time histories using Calcomp pen plotters is described. The program is designed to read a time history data file and to generate time history plots for selected time intervals and/or selected data channels. The capabilities of the program are described. The card input required to define the plotting operation is described and examples of card input and the resulting plotted output are given. The examples are followed by a description of the printed output, including both normal output and error messages. Lastly, implementation of the program is described. A complete listing of the program with reference maps produced by the CDC FTN 5.0 compiler is included.
Economy with the time delay of information flow—The stock market case
NASA Astrophysics Data System (ADS)
Miśkiewicz, Janusz
2012-02-01
Any decision process requires information about the past and present state of the system, but in an economy acquiring data and processing it is an expensive and time-consuming task. Therefore, the state of the system is often measured over some legal interval, analysed after the end of well defined time periods and the results announced much later before any strategic decision is envisaged. The various time delay roles have to be crucially examined. Here, a model of stock market coupled with an economy is investigated to emphasise the role of the time delay span on the information flow. It is shown that the larger the time delay the more important the collective behaviour of agents since one observes time oscillations in the absolute log-return autocorrelations.
Preliminary Investigation of the Satellite Gravitational Red Shift Experiment
NASA Technical Reports Server (NTRS)
Zacharias, J. R.; Searle, C. L.; Graham, J. W.; Badessa, R. S.; Bates, V. J.; Kent, R. L.
1961-01-01
The work performed under this contract involved study, design, and construction of experimental equipment to perform a short-term measurement of the gravitational red shift. In the system designed, phase comparison techniques are employed so that the time interval required to obtain a single measurement for one altitude is of the order of one minute. An elliptical orbit was chosen to permit measurement of frequency shift as a function of altitude. One particularly attractive orbit is that having a 12-hour orbiting period (perigee, 270 miles, apogee 24,800 miles). This orbit, shown in Fig. 1, allows continuous measurements to be made over an 11-hour interval during which time the altitude is varying greatly. Measurements can not be made for the succeeding 14 hours. Since the variation of frequency difference with altitude is of greatest interest, a fixed offset or a slow drift between the oscillator on the ground and. the oscillator in the satellite will not invalidate the measurements.
Manual control models of industrial management
NASA Technical Reports Server (NTRS)
Crossman, E. R. F. W.
1972-01-01
The industrial engineer is often required to design and implement control systems and organization for manufacturing and service facilities, to optimize quality, delivery, and yield, and minimize cost. Despite progress in computer science most such systems still employ human operators and managers as real-time control elements. Manual control theory should therefore be applicable to at least some aspects of industrial system design and operations. Formulation of adequate model structures is an essential prerequisite to progress in this area; since real-world production systems invariably include multilevel and multiloop control, and are implemented by timeshared human effort. A modular structure incorporating certain new types of functional element, has been developed. This forms the basis for analysis of an industrial process operation. In this case it appears that managerial controllers operate in a discrete predictive mode based on fast time modelling, with sampling interval related to plant dynamics. Successive aggregation causes reduced response bandwidth and hence increased sampling interval as a function of level.
Effects of rotor model degradation on the accuracy of rotorcraft real time simulation
NASA Technical Reports Server (NTRS)
Houck, J. A.; Bowles, R. L.
1976-01-01
The effects are studied of degrading a rotating blade element rotor mathematical model to meet various real-time simulation requirements of rotorcraft. Three methods of degradation were studied: reduction of number of blades, reduction of number of blade segments, and increasing the integration interval, which has the corresponding effect of increasing blade azimuthal advance angle. The three degradation methods were studied through static trim comparisons, total rotor force and moment comparisons, single blade force and moment comparisons over one complete revolution, and total vehicle dynamic response comparisons. Recommendations are made concerning model degradation which should serve as a guide for future users of this mathematical model, and in general, they are in order of minimum impact on model validity: (1) reduction of number of blade segments, (2) reduction of number of blades, and (3) increase of integration interval and azimuthal advance angle. Extreme limits are specified beyond which the rotating blade element rotor mathematical model should not be used.
Estis, Julie M; Coblentz, Joana K; Moore, Robert E
2009-07-01
Trained singers (TS) generally demonstrate accurate pitch matching, but this ability varies within the general population. Pitch-matching accuracy, given increasing silence intervals of 5, 15, and 25 seconds between target tones and vocal matches, was investigated in TS and untrained individuals. A relationship between pitch discrimination and pitch matching was also examined. Thirty-two females (20-30 years) were grouped based on individual vocal training and performance in an immediate pitch-matching task. Participants matched target pitches following time delays, and completed a pitch discrimination task, which required the classification of two tones as same or different. TS and untrained accurate participants performed comparably on all pitch-matching tasks, while untrained inaccurate participants performed significantly less accurately than the other two groups. Performances declined across groups as intervals of silence increased, suggesting degradation of pitch matching as pitch memory was taxed. A significant relationship between pitch discrimination and pitch matching was revealed across participants.
Place avoidance learning and memory in a jumping spider.
Peckmezian, Tina; Taylor, Phillip W
2017-03-01
Using a conditioned passive place avoidance paradigm, we investigated the relative importance of three experimental parameters on learning and memory in a salticid, Servaea incana. Spiders encountered an aversive electric shock stimulus paired with one side of a two-sided arena. Our three parameters were the ecological relevance of the visual stimulus, the time interval between trials and the time interval before test. We paired electric shock with either a black or white visual stimulus, as prior studies in our laboratory have demonstrated that S. incana prefer dark 'safe' regions to light ones. We additionally evaluated the influence of two temporal features (time interval between trials and time interval before test) on learning and memory. Spiders exposed to the shock stimulus learned to associate shock with the visual background cue, but the extent to which they did so was dependent on which visual stimulus was present and the time interval between trials. Spiders trained with a long interval between trials (24 h) maintained performance throughout training, whereas spiders trained with a short interval (10 min) maintained performance only when the safe side was black. When the safe side was white, performance worsened steadily over time. There was no difference between spiders tested after a short (10 min) or long (24 h) interval before test. These results suggest that the ecological relevance of the stimuli used and the duration of the interval between trials can influence learning and memory in jumping spiders.
TIME-INTERVAL MEASURING DEVICE
Gross, J.E.
1958-04-15
An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.
Monitoring molecular interactions using photon arrival-time interval distribution analysis
Laurence, Ted A [Livermore, CA; Weiss, Shimon [Los Angels, CA
2009-10-06
A method for analyzing/monitoring the properties of species that are labeled with fluorophores. A detector is used to detect photons emitted from species that are labeled with one or more fluorophores and located in a confocal detection volume. The arrival time of each of the photons is determined. The interval of time between various photon pairs is then determined to provide photon pair intervals. The number of photons that have arrival times within the photon pair intervals is also determined. The photon pair intervals are then used in combination with the corresponding counts of intervening photons to analyze properties and interactions of the molecules including brightness, concentration, coincidence and transit time. The method can be used for analyzing single photon streams and multiple photon streams.
[Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].
Hamela-Olkowska, Anita; Dangel, Joanna
2009-08-01
To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (p<0.001). Fetal heart rate decreased as gestation progressed (p<0.001). Thus, the AV intervals increased with the age of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.
Bayesian analyses of time-interval data for environmental radiation monitoring.
Luo, Peng; Sharp, Julia L; DeVol, Timothy A
2013-01-01
Time-interval (time difference between two consecutive pulses) analysis based on the principles of Bayesian inference was investigated for online radiation monitoring. Using experimental and simulated data, Bayesian analysis of time-interval data [Bayesian (ti)] was compared with Bayesian and a conventional frequentist analysis of counts in a fixed count time [Bayesian (cnt) and single interval test (SIT), respectively]. The performances of the three methods were compared in terms of average run length (ARL) and detection probability for several simulated detection scenarios. Experimental data were acquired with a DGF-4C system in list mode. Simulated data were obtained using Monte Carlo techniques to obtain a random sampling of the Poisson distribution. All statistical algorithms were developed using the R Project for statistical computing. Bayesian analysis of time-interval information provided a similar detection probability as Bayesian analysis of count information, but the authors were able to make a decision with fewer pulses at relatively higher radiation levels. In addition, for the cases with very short presence of the source (< count time), time-interval information is more sensitive to detect a change than count information since the source data is averaged by the background data over the entire count time. The relationships of the source time, change points, and modifications to the Bayesian approach for increasing detection probability are presented.
Fixed-interval matching-to-sample: intermatching time and intermatching error runs1
Nelson, Thomas D.
1978-01-01
Four pigeons were trained on a matching-to-sample task in which reinforcers followed either the first matching response (fixed interval) or the fifth matching response (tandem fixed-interval fixed-ratio) that occurred 80 seconds or longer after the last reinforcement. Relative frequency distributions of the matching-to-sample responses that concluded intermatching times and runs of mismatches (intermatching error runs) were computed for the final matching responses directly followed by grain access and also for the three matching responses immediately preceding the final match. Comparison of these two distributions showed that the fixed-interval schedule arranged for the preferential reinforcement of matches concluding relatively extended intermatching times and runs of mismatches. Differences in matching accuracy and rate during the fixed interval, compared to the tandem fixed-interval fixed-ratio, suggested that reinforcers following matches concluding various intermatching times and runs of mismatches influenced the rate and accuracy of the last few matches before grain access, but did not control rate and accuracy throughout the entire fixed-interval period. PMID:16812032
Improved confidence intervals when the sample is counted an integer times longer than the blank.
Potter, William Edward; Strzelczyk, Jadwiga Jodi
2011-05-01
Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named Neyman confidence intervals or simply confidence intervals. The technique utilized mimics a technique used by Pearson and Hartley to tabulate confidence intervals for the expected value of the discrete Poisson and Binomial distributions. The blank count and the contribution of the sample to the gross count are assumed to be Poisson distributed. The expected value of the blank count, in the sample count time, is assumed known. The net count, OC, is taken to be the gross count minus the product of IRR with the blank count. The probability density function (PDF) for the net count can be determined in a straightforward manner.
The Time Is Up: Compression of Visual Time Interval Estimations of Bimodal Aperiodic Patterns
Duarte, Fabiola; Lemus, Luis
2017-01-01
The ability to estimate time intervals subserves many of our behaviors and perceptual experiences. However, it is not clear how aperiodic (AP) stimuli affect our perception of time intervals across sensory modalities. To address this question, we evaluated the human capacity to discriminate between two acoustic (A), visual (V) or audiovisual (AV) time intervals of trains of scattered pulses. We first measured the periodicity of those stimuli and then sought for correlations with the accuracy and reaction times (RTs) of the subjects. We found that, for all time intervals tested in our experiment, the visual system consistently perceived AP stimuli as being shorter than the periodic (P) ones. In contrast, such a compression phenomenon was not apparent during auditory trials. Our conclusions are: first, the subjects exposed to P stimuli are more likely to measure their durations accurately. Second, perceptual time compression occurs for AP visual stimuli. Lastly, AV discriminations are determined by A dominance rather than by AV enhancement. PMID:28848406
Phase Calibration for the Block 1 VLBI System
NASA Technical Reports Server (NTRS)
Roth, M. G.; Runge, T. F.
1983-01-01
Very Long Baseline Interferometry (VLBI) in the DSN provides support for spacecraft navigation, Earth orientation measurements, and synchronization of network time and frequency standards. An improved method for calibrating instrumental phase shifts has recently been implemented as a computer program in the Block 1 system. The new calibration program, called PRECAL, performs calibrations over intervals as small as 0.4 seconds and greatly reduces the amount of computer processing required to perform phase calibration.
2001-10-01
requirements following surgery. Dextromethorphan , a readily available nonopioid antitussive in clinical use for more than 40 years, is one such NMDA...receptor Anticosti. This prospective, randomized, double blind pilot study compared the effects over time when patients received dextromethorphan versus...groups. Group I received 60 mg of dextromethorphan orally, and Group II received an oral placebo. Postoperative pain was assessed using an 11 point
Method and apparatus for assessing cardiovascular risk
NASA Technical Reports Server (NTRS)
Albrecht, Paul (Inventor); Bigger, J. Thomas (Inventor); Cohen, Richard J. (Inventor)
1998-01-01
The method for assessing risk of an adverse clinical event includes detecting a physiologic signal in the subject and determining from the physiologic signal a sequence of intervals corresponding to time intervals between heart beats. The long-time structure of fluctuations in the intervals over a time period of more than fifteen minutes is analyzed to assess risk of an adverse clinical event. In a preferred embodiment, the physiologic signal is an electrocardiogram and the time period is at least fifteen minutes. A preferred method for analyzing the long-time structure variability in the intervals includes computing the power spectrum and fitting the power spectrum to a power law dependence on frequency over a selected frequency range such as 10.sup.-4 to 10.sup.-2 Hz. Characteristics of the long-time structure fluctuations in the intervals is used to assess risk of an adverse clinical event.
Risk factors for postoperative retropharyngeal hematoma after anterior cervical spine surgery.
O'Neill, Kevin R; Neuman, Brian; Peters, Colleen; Riew, K Daniel
2014-02-15
Retrospective review of prospective database. To investigate risk factors involved in the development of anterior cervical hematomas and determine any impact on patient outcomes. Postoperative (PO) hematomas after anterior cervical spine surgery require urgent recognition and treatment to avoid catastrophic patient morbidity or death. Current studies of PO hematomas are limited. Cervical spine surgical procedures performed on adults by the senior author at a single academic institution from 1995 to 2012 were evaluated. Demographic data, surgical history, operative data, complications, and neck disability index (NDI) scores were recorded prospectively. Cases complicated by PO hematoma were reviewed, and time until hematoma development and surgical evacuation were determined. Patients who developed a hematoma (HT group) were compared with those that did not (no-HT group) to identify risk factors. NDI outcomes were compared at early (<11 mo) and late (>11 mo) time points. There were 2375 anterior cervical spine surgical procedures performed with 17 occurrences (0.7%) of PO hematoma. In 11 patients (65%) the hematoma occurred within 24 hours PO, whereas 6 patients (35%) presented at an average of 6 days postoperatively. All underwent hematoma evacuation, with 2 patients (12%) requiring emergent cricothyroidotomy. Risk factors for hematoma were found to be (1) the presence of diffuse idiopathic skeletal hyperostosis (relative risk = 13.2, 95% confidence interval = 3.2-54.4), (2) presence of ossification of the posterior longitudinal ligament (relative risk = 6.8, 95% confidence interval = 2.3-20.6), (3) therapeutic heparin use (relative risk 148.8, 95% confidence interval = 91.3-242.5), (4) longer operative time, and (5) greater number of surgical levels. The occurrence of a PO hematoma was not found to have a significant impact on either early (HT: 30, no-HT: 28; P = 0.86) or late average NDI scores (HT: 28, no-HT 31; P = 0.76). With fast recognition and treatment, no long-term detriment from PO anterior cervical hematoma was found. We identified risk factors to be (1) presence of diffuse idiopathic skeletal hyperostosis, (2) presence of ossification of the posterior longitudinal ligament, (3) therapeutic heparin use, (4) longer operative time, and (5) greater number of surgical levels. 4.
Time discrimination deficits in schizophrenia patients with first-rank (passivity) symptoms.
Waters, Flavie; Jablensky, Assen
2009-05-15
Schizophrenia patients with first-rank (passivity) symptoms (FRS) report a loss of clear boundaries between the self and others and that their thoughts and actions are controlled by external forces. One of the more widely accepted explanatory models of FRS suggests a dysfunction in the 'forward model' system, whose role consists in predicting the sensory consequences of actions [Frith, C., 2006. The neural basis of hallucinations and delusions. Comptes Rendus Biologies 328, 169-175.]. There has been recent interest in the importance of timing precision underlying both the functioning of the forward model, and in processes contributing to the mechanisms of self-recognition [Haggard, P., Martin, F., Taylor-Clarke, M., Jeannerod, M., Franck, N., 2003. Awareness of action in schizophrenia. Neuroreport 14, 1081-1085.]. In the current study, we examined whether schizophrenia patients with FRS have a time perception impairment, using an auditory discrimination task requiring judgments of temporal intervals. Thirty-five schizophrenia patients (15 with, and 20 without, FRS), and 16 non-clinical controls completed the task. The results showed that patients with FRS experienced time differently by underestimating the duration of time intervals. Given the role of timing in shaping sensory awareness and in the formation of causal mental associations, a breakdown in timing mechanisms may affect the processes relating to the perceived control of actions and mental events, leading to disturbances of self-recognition in FRS.
Flambaum, V V; Kozlov, M G
2007-10-12
Sensitivity to temporal variation of the fundamental constants may be strongly enhanced in transitions between narrow close levels of different nature. This enhancement may be realized in a large number of molecules due to cancellation between the ground state fine-structure omega{f} and vibrational interval omega{v} [omega=omega{f}-nomega{v} approximately 0, delta omega/omega=K(2delta alpha/alpha+0.5 delta mu/mu), K>1, mu=m{p}/m{e}]. The intervals between the levels are conveniently located in microwave frequency range and the level widths are very small. Required accuracy of the shift measurements is about 0.01-1 Hz. As examples, we consider molecules Cl(+)(2), CuS, IrC, SiBr, and HfF(+).
NASA Astrophysics Data System (ADS)
Endreny, Theodore A.; Pashiardis, Stelios
2007-02-01
SummaryRobust and accurate estimates of rainfall frequencies are difficult to make with short, and arid-climate, rainfall records, however new regional and global methods were used to supplement such a constrained 15-34 yr record in Cyprus. The impact of supplementing rainfall frequency analysis with the regional and global approaches was measured with relative bias and root mean square error (RMSE) values. Analysis considered 42 stations with 8 time intervals (5-360 min) in four regions delineated by proximity to sea and elevation. Regional statistical algorithms found the sites passed discordancy tests of coefficient of variation, skewness and kurtosis, while heterogeneity tests revealed the regions were homogeneous to mildly heterogeneous. Rainfall depths were simulated in the regional analysis method 500 times, and then goodness of fit tests identified the best candidate distribution as the general extreme value (GEV) Type II. In the regional analysis, the method of L-moments was used to estimate location, shape, and scale parameters. In the global based analysis, the distribution was a priori prescribed as GEV Type II, a shape parameter was a priori set to 0.15, and a time interval term was constructed to use one set of parameters for all time intervals. Relative RMSE values were approximately equal at 10% for the regional and global method when regions were compared, but when time intervals were compared the global method RMSE had a parabolic-shaped time interval trend. Relative bias values were also approximately equal for both methods when regions were compared, but again a parabolic-shaped time interval trend was found for the global method. The global method relative RMSE and bias trended with time interval, which may be caused by fitting a single scale value for all time intervals.
Heilbronner, Sarah R.; Meck, Warren. H.
2014-01-01
The goal of our study was to characterize the relationship between intertemporal choice and interval timing, including determining how drugs that modulate brain serotonin and dopamine levels influence these two processes. In Experiment 1, rats were tested on a standard 40-s peak-interval procedure following administration of fluoxetine (3, 5, or 8 mg/kg) or vehicle to assess basic effects on interval timing. In Experiment 2, rats were tested in a novel behavioral paradigm intended to simultaneously examine interval timing and impulsivity. Rats performed a variant of the bi-peak procedure using 10-s and 40-s target durations with an additional “defection” lever that provided the possibility of a small, immediate reward. Timing functions remained relatively intact, and ‘patience’ across subjects correlated with peak times, indicating a negative relationship between ‘patience’ and clock speed. We next examined the effects of fluoxetine (5 mg/kg), cocaine (15 mg/kg), or methamphetamine (1 mg/kg) on task performance. Fluoxetine reduced impulsivity as measured by defection time without corresponding changes in clock speed. In contrast, cocaine and methamphetamine both increased impulsivity and clock speed. Thus, variations in timing may mediate intertemporal choice via dopaminergic inputs. However, a separate, serotonergic system can affect intertemporal choice without affecting interval timing directly. PMID:24135569
Shah, Shabir A; Naqash, Talib Amin; Padmanabhan, T V; Subramanium; Lambodaran; Nazir, Shazana
2014-03-01
The sole objective of casting procedure is to provide a metallic duplication of missing tooth structure, with as great accuracy as possible. The ability to produce well fitting castings require strict adherence to certain fundamentals. A study was undertaken to comparatively evaluate the effect on casting accuracy by subjecting the invested wax patterns to burnout after different time intervals. The effect on casting accuracy using metal ring into a pre heated burnout furnace and using split ring was also carried. The readings obtained were tabulated and subjected to statistical analysis.
Gravity and Neuronal Adaptation. Neurophysiology of Reflexes from Hypo- to Hypergravity Conditions
NASA Astrophysics Data System (ADS)
Ritzmann, Ramona; Krause, Anne; Freyler, Kathrin; Gollhofer, Albert
2017-02-01
Introduction: For interplanetary and orbital missions in human space flight, knowledge about the gravity-sensitivity of the central nervous system (CNS) is required. The objective of this study was to assess neurophysiological correlates in variable hetero gravity conditions in regard to their timing and shaping. Methods: In ten subjects, peripheral nerve stimulation was used to elicit H-reflexes and M-waves in the M. soleus in Lunar, Martian, Earth and hypergravity. Gravity-dependencies were described by means of reflex latency, inter-peak-interval, duration, stimulation threshold and maximal amplitudes. Experiments were executed during the CNES/ESA/DLR JEPPFs. Results: H-reflex latency, inter-peak-interval and duration decreased with increasing gravitation (P<0.05); likewise, M-wave inter-peak-interval was diminished and latency prolonged with increasing gravity (P<0.05). Stimulation threshold of H-reflexes and M-waves decreased (P<0.05) while maximal amplitudes increased with an increase in gravitation (P<0.05). Conclusion: Adaptations in neurophysiological correlates in hetero gravity are associated with a shift in timing and shaping. For the first time, our results indicate that synaptic and axonal nerve conduction velocity as well as axonal and spinal excitability are diminished with reduced gravitational forces on the Moon and Mars and gradually increased when gravitation is progressively augmented up to hypergravity. Interrelated with the adaptation in threshold we conclude that neuronal circuitries are significantly affected by gravitation. As a consequence, movement control and countermeasures may be biased in extended space missions involving transitions between different force environments.
Development of a national electronic interval cancer review for breast screening
NASA Astrophysics Data System (ADS)
Halling-Brown, M. D.; Patel, M. N.; Wallis, M. G.; Young, K. C.
2018-03-01
Reviewing interval cancers and prior screening mammograms are a key measure to monitor screening performance. Radiological analysis of the imaging features in prior mammograms and retrospective classification are an important educational tool for readers to improve individual performance. The requirements of remote, collaborative image review sessions, such as those required to run a remote interval cancer review, are variable and demand a flexible and configurable software solution that is not currently available on commercial workstations. The wide range of requirements for both collection and remote review of interval cancers has precipitated the creation of extensible medical image viewers and accompanying systems. In order to allow remote viewing, an application has been designed to allow workstation-independent, PACS-less viewing and interaction with medical images in a remote, collaborative manner, providing centralised reporting and web-based feedback. A semi-automated process, which allows the centralisation of interval cancer cases, has been developed. This stand-alone, flexible image collection toolkit provides the extremely important function of bespoke, ad-hoc image collection at sites where there is no dedicated hardware. Web interfaces have been created which allow a national or regional administrator to organise, coordinate and administer interval cancer review sessions and deploy invites to session members to participate. The same interface allows feedback to be analysed and distributed. The eICR provides a uniform process for classifying interval cancers across the NHSBSP, which facilitates rapid access to a robust 'external' review for patients and their relatives seeking answers about why their cancer was 'missed'.
Automatic vehicle monitoring systems study. Report of phase O. Volume 1: Executive summary
NASA Technical Reports Server (NTRS)
1977-01-01
A set of planning guidelines is presented to help law enforcement agencies and vehicle fleet operators decide which automatic vehicle monitoring (AVM) system could best meet their performance requirements. Improvements in emergency response times and resultant cost benefits obtainable with various operational and planned AVM systems may be synthesized and simulated by means of special computer programs for model city parameters applicable to small, medium, and large urban areas. Design characteristics of various AVM systems and the implementation requirements are illustrated and cost estimated for the vehicles, the fixed sites, and the base equipments. Vehicle location accuracies for different RF links and polling intervals are analyzed.
NASA Technical Reports Server (NTRS)
Quilligan, Gerard; DeMonthier, Jeffrey; Suarez, George
2011-01-01
This innovation addresses challenges in lidar imaging, particularly with the detection scheme and the shapes of the detected signals. Ideally, the echoed pulse widths should be extremely narrow to resolve fine detail at high event rates. However, narrow pulses require wideband detection circuitry with increased power dissipation to minimize thermal noise. Filtering is also required to shape each received signal into a form suitable for processing by a constant fraction discriminator (CFD) followed by a time-to-digital converter (TDC). As the intervals between the echoes decrease, the finite bandwidth of the shaping circuits blends the pulses into an analog signal (luminance) with multiple modes, reducing the ability of the CFD to discriminate individual events
NASA Astrophysics Data System (ADS)
Olafsdottir, Kristin B.; Mudelsee, Manfred
2013-04-01
Estimation of the Pearson's correlation coefficient between two time series to evaluate the influences of one time depended variable on another is one of the most often used statistical method in climate sciences. Various methods are used to estimate confidence interval to support the correlation point estimate. Many of them make strong mathematical assumptions regarding distributional shape and serial correlation, which are rarely met. More robust statistical methods are needed to increase the accuracy of the confidence intervals. Bootstrap confidence intervals are estimated in the Fortran 90 program PearsonT (Mudelsee, 2003), where the main intention was to get an accurate confidence interval for correlation coefficient between two time series by taking the serial dependence of the process that generated the data into account. However, Monte Carlo experiments show that the coverage accuracy for smaller data sizes can be improved. Here we adapt the PearsonT program into a new version called PearsonT3, by calibrating the confidence interval to increase the coverage accuracy. Calibration is a bootstrap resampling technique, which basically performs a second bootstrap loop or resamples from the bootstrap resamples. It offers, like the non-calibrated bootstrap confidence intervals, robustness against the data distribution. Pairwise moving block bootstrap is used to preserve the serial correlation of both time series. The calibration is applied to standard error based bootstrap Student's t confidence intervals. The performances of the calibrated confidence intervals are examined with Monte Carlo simulations, and compared with the performances of confidence intervals without calibration, that is, PearsonT. The coverage accuracy is evidently better for the calibrated confidence intervals where the coverage error is acceptably small (i.e., within a few percentage points) already for data sizes as small as 20. One form of climate time series is output from numerical models which simulate the climate system. The method is applied to model data from the high resolution ocean model, INALT01 where the relationship between the Agulhas Leakage and the North Brazil Current is evaluated. Preliminary results show significant correlation between the two variables when there is 10 year lag between them, which is more or less the time that takes the Agulhas Leakage water to reach the North Brazil Current. Mudelsee, M., 2003. Estimating Pearson's correlation coefficient with bootstrap confidence interval from serially dependent time series. Mathematical Geology 35, 651-665.
Viana, Duarte S; Santamaría, Luis; Figuerola, Jordi
2016-02-01
Propagule retention time is a key factor in determining propagule dispersal distance and the shape of "seed shadows". Propagules dispersed by animal vectors are either ingested and retained in the gut until defecation or attached externally to the body until detachment. Retention time is a continuous variable, but it is commonly measured at discrete time points, according to pre-established sampling time-intervals. Although parametric continuous distributions have been widely fitted to these interval-censored data, the performance of different fitting methods has not been evaluated. To investigate the performance of five different fitting methods, we fitted parametric probability distributions to typical discretized retention-time data with known distribution using as data-points either the lower, mid or upper bounds of sampling intervals, as well as the cumulative distribution of observed values (using either maximum likelihood or non-linear least squares for parameter estimation); then compared the estimated and original distributions to assess the accuracy of each method. We also assessed the robustness of these methods to variations in the sampling procedure (sample size and length of sampling time-intervals). Fittings to the cumulative distribution performed better for all types of parametric distributions (lognormal, gamma and Weibull distributions) and were more robust to variations in sample size and sampling time-intervals. These estimated distributions had negligible deviations of up to 0.045 in cumulative probability of retention times (according to the Kolmogorov-Smirnov statistic) in relation to original distributions from which propagule retention time was simulated, supporting the overall accuracy of this fitting method. In contrast, fitting the sampling-interval bounds resulted in greater deviations that ranged from 0.058 to 0.273 in cumulative probability of retention times, which may introduce considerable biases in parameter estimates. We recommend the use of cumulative probability to fit parametric probability distributions to propagule retention time, specifically using maximum likelihood for parameter estimation. Furthermore, the experimental design for an optimal characterization of unimodal propagule retention time should contemplate at least 500 recovered propagules and sampling time-intervals not larger than the time peak of propagule retrieval, except in the tail of the distribution where broader sampling time-intervals may also produce accurate fits.
Factors influencing pre-hospital care time intervals in Iran: a qualitative study.
Khorasani-Zavareh, Davoud; Mohammadi, Reza; Bohm, Katarina
2018-06-23
Pre-hospital time management provides better access to victims of road traffic crashes (RTCs) and can help minimize preventable deaths, injuries and disabilities. While most studies have been focused on measuring various time intervals in the pre-hospital phase, to our best knowledge there is no study exploring the barriers and facilitators that affects these various intervals qualitatively. The present study aimed to explore factors affecting various time intervals relating to road traffic incidents in the pre-hospital phase and provides suggestions for improvements in Iran. The study was conducted during 2013-2014 at both the national and local level in Iran. Overall, 18 face-to-face interviews with emergency medical services (EMS) personnel were used for data collection. Qualitative content analysis was employed to analyze the data. The most important barriers in relation to pre-hospital intervals were related to the manner of cooperation by members of the public with the EMS and their involvement at the crash scene, as well as to pre-hospital system factors, including the number and location of EMS facilities, type and number of ambulances and manpower. These factors usually affect how rapidly the EMS can arrive at the scene of the crash and how quickly victims can be transferred to hospital. These two categories have six main themes: notification interval; activation interval; response interval; on-scene interval; transport interval; and delivery interval. Despite more focus on physical resources, cooperation from members of the public needs to be taken in account in order to achieve better pre-hospital management of the various intervals, possibly through the use of public education campaigns.
Interval stability for complex systems
NASA Astrophysics Data System (ADS)
Klinshov, Vladimir V.; Kirillov, Sergey; Kurths, Jürgen; Nekorkin, Vladimir I.
2018-04-01
Stability of dynamical systems against strong perturbations is an important problem of nonlinear dynamics relevant to many applications in various areas. Here, we develop a novel concept of interval stability, referring to the behavior of the perturbed system during a finite time interval. Based on this concept, we suggest new measures of stability, namely interval basin stability (IBS) and interval stability threshold (IST). IBS characterizes the likelihood that the perturbed system returns to the stable regime (attractor) in a given time. IST provides the minimal magnitude of the perturbation capable to disrupt the stable regime for a given interval of time. The suggested measures provide important information about the system susceptibility to external perturbations which may be useful for practical applications. Moreover, from a theoretical viewpoint the interval stability measures are shown to bridge the gap between linear and asymptotic stability. We also suggest numerical algorithms for quantification of the interval stability characteristics and demonstrate their potential for several dynamical systems of various nature, such as power grids and neural networks.
Atomic temporal interval relations in branching time: calculation and application
NASA Astrophysics Data System (ADS)
Anger, Frank D.; Ladkin, Peter B.; Rodriguez, Rita V.
1991-03-01
A practical method of reasoning about intervals in a branching-time model which is dense, unbounded, future-branching, without rejoining branches is presented. The discussion is based on heuristic constraint- propagation techniques using the relation algebra of binary temporal relations among the intervals over the branching-time model. This technique has been applied with success to models of intervals over linear time by Allen and others, and is of cubic-time complexity. To extend it to branding-time models, it is necessary to calculate compositions of the relations; thus, the table of compositions for the 'atomic' relations is computed, enabling the rapid determination of the composition of arbitrary relations, expressed as disjunctions or unions of the atomic relations.
Analysis of single ion channel data incorporating time-interval omission and sampling
The, Yu-Kai; Timmer, Jens
2005-01-01
Hidden Markov models are widely used to describe single channel currents from patch-clamp experiments. The inevitable anti-aliasing filter limits the time resolution of the measurements and therefore the standard hidden Markov model is not adequate anymore. The notion of time-interval omission has been introduced where brief events are not detected. The developed, exact solutions to this problem do not take into account that the measured intervals are limited by the sampling time. In this case the dead-time that specifies the minimal detectable interval length is not defined unambiguously. We show that a wrong choice of the dead-time leads to considerably biased estimates and present the appropriate equations to describe sampled data. PMID:16849220
Designing efficient nitrous oxide sampling strategies in agroecosystems using simulation models
NASA Astrophysics Data System (ADS)
Saha, Debasish; Kemanian, Armen R.; Rau, Benjamin M.; Adler, Paul R.; Montes, Felipe
2017-04-01
Annual cumulative soil nitrous oxide (N2O) emissions calculated from discrete chamber-based flux measurements have unknown uncertainty. We used outputs from simulations obtained with an agroecosystem model to design sampling strategies that yield accurate cumulative N2O flux estimates with a known uncertainty level. Daily soil N2O fluxes were simulated for Ames, IA (corn-soybean rotation), College Station, TX (corn-vetch rotation), Fort Collins, CO (irrigated corn), and Pullman, WA (winter wheat), representing diverse agro-ecoregions of the United States. Fertilization source, rate, and timing were site-specific. These simulated fluxes surrogated daily measurements in the analysis. We ;sampled; the fluxes using a fixed interval (1-32 days) or a rule-based (decision tree-based) sampling method. Two types of decision trees were built: a high-input tree (HI) that included soil inorganic nitrogen (SIN) as a predictor variable, and a low-input tree (LI) that excluded SIN. Other predictor variables were identified with Random Forest. The decision trees were inverted to be used as rules for sampling a representative number of members from each terminal node. The uncertainty of the annual N2O flux estimation increased along with the fixed interval length. A 4- and 8-day fixed sampling interval was required at College Station and Ames, respectively, to yield ±20% accuracy in the flux estimate; a 12-day interval rendered the same accuracy at Fort Collins and Pullman. Both the HI and the LI rule-based methods provided the same accuracy as that of fixed interval method with up to a 60% reduction in sampling events, particularly at locations with greater temporal flux variability. For instance, at Ames, the HI rule-based and the fixed interval methods required 16 and 91 sampling events, respectively, to achieve the same absolute bias of 0.2 kg N ha-1 yr-1 in estimating cumulative N2O flux. These results suggest that using simulation models along with decision trees can reduce the cost and improve the accuracy of the estimations of cumulative N2O fluxes using the discrete chamber-based method.
Martin, A.D.
1986-05-09
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay provides a first output signal at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits latch the high resolution data to form a first synchronizing data set. A selected time interval has been preset to internal counters and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses count down the counters to generate an internal pulse delayed by an internal which is functionally related to the preset time interval. A second LCD corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD to generate a second set of synchronizing data which is complementary with the first set of synchronizing data for presentation to logic circuits. The logic circuits further delay the internal output signal with the internal pulses. The final delayed output signal thereafter enables the output pulse generator to produce the desired output pulse at the preset time delay interval following input of the trigger pulse.
Kapur, Ajay; Adair, Nilda; O'Brien, Mildred; Naparstek, Nikoleta; Cangelosi, Thomas; Zuvic, Petrina; Joseph, Sherin; Meier, Jason; Bloom, Beatrice; Potters, Louis
Modern external beam radiation therapy treatment delivery processes potentially increase the number of tasks to be performed by therapists and thus opportunities for errors, yet the need to treat a large number of patients daily requires a balanced allocation of time per treatment slot. The goal of this work was to streamline the underlying workflow in such time-interval constrained processes to enhance both execution efficiency and active safety surveillance using a Kaizen approach. A Kaizen project was initiated by mapping the workflow within each treatment slot for 3 Varian TrueBeam linear accelerators. More than 90 steps were identified, and average execution times for each were measured. The time-consuming steps were stratified into a 2 × 2 matrix arranged by potential workflow improvement versus the level of corrective effort required. A work plan was created to launch initiatives with high potential for workflow improvement but modest effort to implement. Time spent on safety surveillance and average durations of treatment slots were used to assess corresponding workflow improvements. Three initiatives were implemented to mitigate unnecessary therapist motion, overprocessing of data, and wait time for data transfer defects, respectively. A fourth initiative was implemented to make the division of labor by treating therapists as well as peer review more explicit. The average duration of treatment slots reduced by 6.7% in the 9 months following implementation of the initiatives (P = .001). A reduction of 21% in duration of treatment slots was observed on 1 of the machines (P < .001). Time spent on safety reviews remained the same (20% of the allocated interval), but the peer review component increased. The Kaizen approach has the potential to improve operational efficiency and safety with quick turnaround in radiation therapy practice by addressing non-value-adding steps characteristic of individual department workflows. Higher effort opportunities are identified to guide continual downstream quality improvements. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Accuracy and Precision of Visual Stimulus Timing in PsychoPy: No Timing Errors in Standard Usage
Garaizar, Pablo; Vadillo, Miguel A.
2014-01-01
In a recent report published in PLoS ONE, we found that the performance of PsychoPy degraded with very short timing intervals, suggesting that it might not be perfectly suitable for experiments requiring the presentation of very brief stimuli. The present study aims to provide an updated performance assessment for the most recent version of PsychoPy (v1.80) under different hardware/software conditions. Overall, the results show that PsychoPy can achieve high levels of precision and accuracy in the presentation of brief visual stimuli. Although occasional timing errors were found in very demanding benchmarking tests, there is no reason to think that they can pose any problem for standard experiments developed by researchers. PMID:25365382
Smelling time: a neural basis for olfactory scene analysis
Ache, Barry W.; Hein, Andrew M.; Bobkov, Yuriy V.; Principe, Jose C.
2016-01-01
Behavioral evidence from phylogenetically diverse animals and humans suggests that olfaction could be much more involved in interpreting space and time than heretofore imagined by extracting temporal information inherent in the olfactory signal. If this is the case, the olfactory system must have neural mechanisms capable of encoding time at intervals relevant to the turbulent odor world in which many animals live. We review evidence that animals can use populations of rhythmically active or ‘bursting’ olfactory receptor neurons (bORNs) to extract and encode temporal information inherent in natural olfactory signals. We postulate that bORNs represent an unsuspected neural mechanism through which time can be accurately measured, and that ‘smelling time’ completes the requirements for true olfactory scene analysis. PMID:27594700
Method for Direct Measurement of Cosmic Acceleration by 21-cm Absorption Systems
NASA Astrophysics Data System (ADS)
Yu, Hao-Ran; Zhang, Tong-Jie; Pen, Ue-Li
2014-07-01
So far there is only indirect evidence that the Universe is undergoing an accelerated expansion. The evidence for cosmic acceleration is based on the observation of different objects at different distances and requires invoking the Copernican cosmological principle and Einstein's equations of motion. We examine the direct observability using recession velocity drifts (Sandage-Loeb effect) of 21-cm hydrogen absorption systems in upcoming radio surveys. This measures the change in velocity of the same objects separated by a time interval and is a model-independent measure of acceleration. We forecast that for a CHIME-like survey with a decade time span, we can detect the acceleration of a ΛCDM universe with 5σ confidence. This acceleration test requires modest data analysis and storage changes from the normal processing and cannot be recovered retroactively.
Rukuni, Ruramayi; Bhattacharya, Sohinee; Murphy, Michael F; Roberts, David; Stanworth, Simon J; Knight, Marian
2016-05-01
Antenatal anemia is a major public health problem in the UK, yet there is limited high quality evidence for associated poor clinical outcomes. The objectives of this study were to estimate the incidence and clinical outcomes of antenatal anemia in a Scottish population. A retrospective cohort study of 80 422 singleton pregnancies was conducted using data from the Aberdeen Maternal and Neonatal Databank between 1995 and 2012. Antenatal anemia was defined as haemoglobin ≤ 10 g/dl during pregnancy. Incidence was calculated with 95% confidence intervals and compared over time using a chi-squared test for trend. Multivariable logistic regression was used to adjust for confounding variables. Results are presented as adjusted odds ratios with 95% confidence interval. The overall incidence of antenatal anemia was 9.3 cases/100 singleton pregnancies (95% confidence interval 9.1-9.5), decreasing from 16.9/100 to 4.1/100 singleton pregnancies between 1995 and 2012 (p < 0.001). Maternal anemia was associated with antepartum hemorrhage (adjusted odds ratio 1.26, 95% confidence interval 1.17-1.36), postpartum infection (adjusted odds ratio 1.89, 95% confidence interval 1.39-2.57), transfusion (adjusted odds ratio 1.87, 95% confidence interval 1.65-2.13) and stillbirth (adjusted odds ratio 1.42, 95% confidence interval 1.04-1.94), reduced odds of postpartum hemorrhage (adjusted odds ratio 0.92, 95% confidence interval 0.86-0.98) and low birthweight (adjusted odds ratio 0.77, 95% confidence interval 0.69-0.86). No other outcomes were statistically significant. This study shows the incidence of antenatal anemia is decreasing steadily within this Scottish population. However, given that anemia is a readily correctable risk factor for major causes of morbidity and mortality in the UK, further work is required to investigate appropriate preventive measures. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Influence of computer work under time pressure on cardiac activity.
Shi, Ping; Hu, Sijung; Yu, Hongliu
2015-03-01
Computer users are often under stress when required to complete computer work within a required time. Work stress has repeatedly been associated with an increased risk for cardiovascular disease. The present study examined the effects of time pressure workload during computer tasks on cardiac activity in 20 healthy subjects. Heart rate, time domain and frequency domain indices of heart rate variability (HRV) and Poincaré plot parameters were compared among five computer tasks and two rest periods. Faster heart rate and decreased standard deviation of R-R interval were noted in response to computer tasks under time pressure. The Poincaré plot parameters showed significant differences between different levels of time pressure workload during computer tasks, and between computer tasks and the rest periods. In contrast, no significant differences were identified for the frequency domain indices of HRV. The results suggest that the quantitative Poincaré plot analysis used in this study was able to reveal the intrinsic nonlinear nature of the autonomically regulated cardiac rhythm. Specifically, heightened vagal tone occurred during the relaxation computer tasks without time pressure. In contrast, the stressful computer tasks with added time pressure stimulated cardiac sympathetic activity. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dolman, Bronwyn; Verrall, Geoffrey; Reid, Iain
2014-01-01
Summary Of the hamstring muscle group the biceps femoris muscle is the most commonly injured muscle in sports requiring interval sprinting. The reason for this observation is unknown. The objective of this study was to calculate the forces of all three hamstring muscles, relative to each other, during a lengthening contraction to assess for any differences that may help explain the biceps femoris predilection for injury during interval sprinting. To calculate the displacement of each individual hamstring muscle previously performed studies on cadaveric anatomical data and hamstring kinematics during sprinting were used. From these displacement calculations for each individual hamstring muscle physical principles were then used to deduce the proportion of force exerted by each individual hamstring muscle during a lengthening muscle contraction. These deductions demonstrate that the biceps femoris muscle is required to exert proportionally more force in a lengthening muscle contraction relative to the semimembranosus and semitendinosus muscles primarily as a consequence of having to lengthen over a greater distance within the same time frame. It is hypothesized that this property maybe a factor in the known observation of the increased susceptibility of the biceps femoris muscle to injury during repeated sprints where recurrent higher force is required. PMID:25506583
Dolman, Bronwyn; Verrall, Geoffrey; Reid, Iain
2014-07-01
Of the hamstring muscle group the biceps femoris muscle is the most commonly injured muscle in sports requiring interval sprinting. The reason for this observation is unknown. The objective of this study was to calculate the forces of all three hamstring muscles, relative to each other, during a lengthening contraction to assess for any differences that may help explain the biceps femoris predilection for injury during interval sprinting. To calculate the displacement of each individual hamstring muscle previously performed studies on cadaveric anatomical data and hamstring kinematics during sprinting were used. From these displacement calculations for each individual hamstring muscle physical principles were then used to deduce the proportion of force exerted by each individual hamstring muscle during a lengthening muscle contraction. These deductions demonstrate that the biceps femoris muscle is required to exert proportionally more force in a lengthening muscle contraction relative to the semimembranosus and semitendinosus muscles primarily as a consequence of having to lengthen over a greater distance within the same time frame. It is hypothesized that this property maybe a factor in the known observation of the increased susceptibility of the biceps femoris muscle to injury during repeated sprints where recurrent higher force is required.
NASA Technical Reports Server (NTRS)
Bergman, S. A., Jr.; Johnson, R. L.; Hoffler, G. W.
1977-01-01
Devices and techniques for measuring and analyzing systolic time intervals and quantitative phonocardiograms were initiated during Apollo 17. The data show that the systolic time interval from Apollo 17 crewmen remained elevated longer postflight than the response criteria of heart rate, blood pressure, and percent change in leg volume all of which had returned to preflight levels by the second day postflight. Although the systolic time interval values were only slightly outside the preflight fiducial limits, this finding suggested that: the analysis of systolic time intervals may help to identify the mechanisms of postflight orthostatic intolerance by virtue of measuring ventricular function more directly and, the noninvasive technique may prove useful in determining the extent and duration of cardiovascular instability after long duration space flight. The systolic time intervals obtained on the Apollo 17 crewmen during lower body negative pressure were similar to those noted in patients with significant heart disease.
Alluri, Nagamalleswara Rao; Vivekananthan, Venkateswaran; Chandrasekhar, Arunkumar; Kim, Sang-Jae
2018-01-18
Contrary to traditional planar flexible piezoelectric nanogenerators (PNGs), highly adaptable hemispherical shape-flexible piezoelectric composite strip (HS-FPCS) based PNGs are required to harness/measure non-linear surface motions. Therefore, a feasible, cost-effective and less-time consuming groove technique was developed to fabricate adaptable HS-FPCSs with multiple lengths. A single HS-CSPNG generates 130 V/0.8 μA and can also work as a self-powered muscle monitoring system (SP-MMS) to measure maximum human body part movements, i.e., spinal cord, throat, jaw, elbow, knee, foot stress, palm hand/finger force and inhale/exhale breath conditions at a time or at variable time intervals.
On the identification of a Pliocene time slice for data–model comparison
Haywood, Alan M.; Dolan, Aisling M.; Pickering, Steven J.; Dowsett, Harry J.; McClymont, Erin L.; Prescott, Caroline L.; Salzmann, Ulrich; Hill, Daniel J.; Hunter, Stephen J.; Lunt, Daniel J.; Pope, James O.; Valdes, Paul J.
2013-01-01
The characteristics of the mid-Pliocene warm period (mPWP: 3.264–3.025 Ma BP) have been examined using geological proxies and climate models. While there is agreement between models and data, details of regional climate differ. Uncertainties in prescribed forcings and in proxy data limit the utility of the interval to understand the dynamics of a warmer than present climate or evaluate models. This uncertainty comes, in part, from the reconstruction of a time slab rather than a time slice, where forcings required by climate models can be more adequately constrained. Here, we describe the rationale and approach for identifying a time slice(s) for Pliocene environmental reconstruction. A time slice centred on 3.205 Ma BP (3.204–3.207 Ma BP) has been identified as a priority for investigation. It is a warm interval characterized by a negative benthic oxygen isotope excursion (0.21–0.23‰) centred on marine isotope stage KM5c (KM5.3). It occurred during a period of orbital forcing that was very similar to present day. Climate model simulations indicate that proxy temperature estimates are unlikely to be significantly affected by orbital forcing for at least a precession cycle centred on the time slice, with the North Atlantic potentially being an important exception.
Evaluating the efficiency of environmental monitoring programs
Levine, Carrie R.; Yanai, Ruth D.; Lampman, Gregory G.; Burns, Douglas A.; Driscoll, Charles T.; Lawrence, Gregory B.; Lynch, Jason; Schoch, Nina
2014-01-01
Statistical uncertainty analyses can be used to improve the efficiency of environmental monitoring, allowing sampling designs to maximize information gained relative to resources required for data collection and analysis. In this paper, we illustrate four methods of data analysis appropriate to four types of environmental monitoring designs. To analyze a long-term record from a single site, we applied a general linear model to weekly stream chemistry data at Biscuit Brook, NY, to simulate the effects of reducing sampling effort and to evaluate statistical confidence in the detection of change over time. To illustrate a detectable difference analysis, we analyzed a one-time survey of mercury concentrations in loon tissues in lakes in the Adirondack Park, NY, demonstrating the effects of sampling intensity on statistical power and the selection of a resampling interval. To illustrate a bootstrapping method, we analyzed the plot-level sampling intensity of forest inventory at the Hubbard Brook Experimental Forest, NH, to quantify the sampling regime needed to achieve a desired confidence interval. Finally, to analyze time-series data from multiple sites, we assessed the number of lakes and the number of samples per year needed to monitor change over time in Adirondack lake chemistry using a repeated-measures mixed-effects model. Evaluations of time series and synoptic long-term monitoring data can help determine whether sampling should be re-allocated in space or time to optimize the use of financial and human resources.
On the identification of a Pliocene time slice for data–model comparison
Haywood, Alan M.; Dolan, Aisling M.; Pickering, Steven J.; Dowsett, Harry J.; McClymont, Erin L.; Prescott, Caroline L.; Salzmann, Ulrich; Hill, Daniel J.; Hunter, Stephen J.; Lunt, Daniel J.; Pope, James O.; Valdes, Paul J.
2013-01-01
The characteristics of the mid-Pliocene warm period (mPWP: 3.264–3.025 Ma BP) have been examined using geological proxies and climate models. While there is agreement between models and data, details of regional climate differ. Uncertainties in prescribed forcings and in proxy data limit the utility of the interval to understand the dynamics of a warmer than present climate or evaluate models. This uncertainty comes, in part, from the reconstruction of a time slab rather than a time slice, where forcings required by climate models can be more adequately constrained. Here, we describe the rationale and approach for identifying a time slice(s) for Pliocene environmental reconstruction. A time slice centred on 3.205 Ma BP (3.204–3.207 Ma BP) has been identified as a priority for investigation. It is a warm interval characterized by a negative benthic oxygen isotope excursion (0.21–0.23‰) centred on marine isotope stage KM5c (KM5.3). It occurred during a period of orbital forcing that was very similar to present day. Climate model simulations indicate that proxy temperature estimates are unlikely to be significantly affected by orbital forcing for at least a precession cycle centred on the time slice, with the North Atlantic potentially being an important exception. PMID:24043865
Honeine, Jean-Louis; Schieppati, Marco
2014-01-01
Maintaining equilibrium is basically a sensorimotor integration task. The central nervous system (CNS) continually and selectively weights and rapidly integrates sensory inputs from multiple sources, and coordinates multiple outputs. The weighting process is based on the availability and accuracy of afferent signals at a given instant, on the time-period required to process each input, and possibly on the plasticity of the relevant pathways. The likelihood that sensory inflow changes while balancing under static or dynamic conditions is high, because subjects can pass from a dark to a well-lit environment or from a tactile-guided stabilization to loss of haptic inflow. This review article presents recent data on the temporal events accompanying sensory transition, on which basic information is fragmentary. The processing time from sensory shift to reaching a new steady state includes the time to (a) subtract or integrate sensory inputs; (b) move from allocentric to egocentric reference or vice versa; and (c) adjust the calibration of motor activity in time and amplitude to the new sensory set. We present examples of processes of integration of posture-stabilizing information, and of the respective sensorimotor time-intervals while allowing or occluding vision or adding or subtracting tactile information. These intervals are short, in the order of 1–2 s for different postural conditions, modalities and deliberate or passive shift. They are just longer for haptic than visual shift, just shorter on withdrawal than on addition of stabilizing input, and on deliberate than unexpected mode. The delays are the shortest (for haptic shift) in blind subjects. Since automatic balance stabilization may be vulnerable to sensory-integration delays and to interference from concurrent cognitive tasks in patients with sensorimotor problems, insight into the processing time for balance control represents a critical step in the design of new balance- and locomotion training devices. PMID:25339872
Screening for Learning and Memory Mutations: A New Approach.
Gallistel, C R; King, A P; Daniel, A M; Freestone, D; Papachristos, E B; Balci, F; Kheifets, A; Zhang, J; Su, X; Schiff, G; Kourtev, H
2010-01-30
We describe a fully automated, live-in 24/7 test environment, with experimental protocols that measure the accuracy and precision with which mice match the ratio of their expected visit durations to the ratio of the incomes obtained from two hoppers, the progress of instrumental and classical conditioning (trials-to-acquisition), the accuracy and precision of interval timing, the effect of relative probability on the choice of a timed departure target, and the accuracy and precision of memory for the times of day at which food is available. The system is compact; it obviates the handling of the mice during testing; it requires negligible amounts of experimenter/technician time; and it delivers clear and extensive results from 3 protocols within a total of 7-9 days after the mice are placed in the test environment. Only a single 24-hour period is required for the completion of first protocol (the matching protocol), which is strong test of temporal and spatial estimation and memory mechanisms. Thus, the system permits the extensive screening of many mice in a short period of time and in limited space. The software is publicly available.
Contracting for Agile Software Development in the Department of Defense: An Introduction
2015-08-01
Requirements are fixed at a more granular level; reviews of the work product happen more frequently and assess each individual increment rather than a “ big bang ...boundaries than “ big - bang ” development. The implementation of incremental or progressive reviews enables just that—any issues identified at the time of the...the contract needs to support the delivery of deployable software at defined increments/intervals, rather than incentivizing “ big - bang ” efforts or
Compression based entropy estimation of heart rate variability on multiple time scales.
Baumert, Mathias; Voss, Andreas; Javorka, Michal
2013-01-01
Heart rate fluctuates beat by beat in a complex manner. The aim of this study was to develop a framework for entropy assessment of heart rate fluctuations on multiple time scales. We employed the Lempel-Ziv algorithm for lossless data compression to investigate the compressibility of RR interval time series on different time scales, using a coarse-graining procedure. We estimated the entropy of RR interval time series of 20 young and 20 old subjects and also investigated the compressibility of randomly shuffled surrogate RR time series. The original RR time series displayed significantly smaller compression entropy values than randomized RR interval data. The RR interval time series of older subjects showed significantly different entropy characteristics over multiple time scales than those of younger subjects. In conclusion, data compression may be useful approach for multiscale entropy assessment of heart rate variability.
Virtual reality laparoscopy: which potential trainee starts with a higher proficiency level?
Paschold, M; Schröder, M; Kauff, D W; Gorbauch, T; Herzer, M; Lang, H; Kneist, W
2011-09-01
Minimally invasive surgery requires technical skills distinct from those used in conventional surgery. The aim of this prospective study was to identify personal characteristics that may predict the attainable proficiency level of first-time virtual reality laparoscopy (VRL) trainees. Two hundred and seventy-nine consecutive undergraduate medical students without experience attended a standardized VRL training. Performance data of an abstract and a procedural task were correlated with possible predictive factors providing potential competence in VRL. Median global score requirement status was 86.7% (interquartile range (IQR) 75-93) for the abstract task and 74.4% (IQR 67-88) for the procedural task. Unadjusted analysis showed significant increase in the global score in both tasks for trainees who had a gaming console at home and frequently used it as well as for trainees who felt self-confident to assist in a laparoscopic operation. Multiple logistic regression analysis identified frequency of video gaming (often/frequently vs. rarely/not at all, odds ratio: abstract model 2.1 (95% confidence interval 1.2; 3.6), P = 0.009; virtual reality operation procedure 2.4 (95% confidence interval 1.3; 4.2), P = 0.003) as a predictive factor for VRL performance. Frequency of video gaming is associated with quality of first-time VRL performance. Video game experience may be used as trainee selection criteria for tailored concepts of VRL training programs.
Setting the Revisit Interval in Primary Care
Schwartz, Lisa M; Woloshin, Steven; Wasson, John H; Renfrew, Roger A; Welch, H Gilbert
1999-01-01
OBJECTIVE Although longitudinal care constitutes the bulk of primary care, physicians receive little guidance on the fundamental question of how to time follow-up visits. We sought to identify important predictors of the revisit interval and to describe the variability in how physicians set these intervals when caring for patients with common medical conditions. DESIGN Cross-sectional survey of physicians performed at the end of office visits for consecutive patients with hypertension, angina, diabetes, or musculoskeletal pain. PARTICIPANTS/SETTING One hundred sixty-four patients under the care of 11 primary care physicians in the Dartmouth Primary Care Cooperative Research Network. MEASUREMENTS The main outcome measures were the variability in mean revisit intervals across physicians and the proportion of explained variance by potential determinants of revisit intervals. We assessed the relation between the revisit interval (dependent variable) and three groups of independent variables, patient characteristics (e.g., age, physician perception of patient health), identification of individual physician, and physician characterization of the visit (e.g., routine visit, visit requiring a change in management, or visit occurring on a “hectic” day), using multiple regression that accounted for the natural grouping of patients within physician. MAIN RESULTS Revisit intervals ranged from 1 week to over 1 year. The most common intervals were 12 and 16 weeks. Physicians’ perception of fair-poor health status and visits involving a change in management were most strongly related to shorter revisit intervals. In multivariate analyses, patient characteristics explained about 18% of the variance in revisit intervals, and adding identification of the individual provider doubled the explained variance to about 40%. Physician characterization of the visit increased explained variance to 57%. The average revisit interval adjusted for patient characteristics for each of the 11 physicians varied from 4 to 20 weeks. Although all physicians lengthened revisit intervals for routine visits and shortened them when changing management, the relative ranking of mean revisit intervals for each physician changed little for different visit characterizations—some physicians were consistently long and others were consistently short. CONCLUSION Physicians vary widely in their recommendations for office revisits. Patient factors accounted for only a small part of this variation. Although physicians responded to visits in predictable ways, each physician appeared to have a unique set point for the length of the revisits interval. PMID:10203635
Computer assisted thermal-vacuum testing
NASA Technical Reports Server (NTRS)
Petrie, W.; Mikk, G.
1977-01-01
In testing complex systems and components under dynamic thermal-vacuum environments, it is desirable to optimize the environment control sequence in order to reduce test duration and cost. This paper describes an approach where a computer is utilized as part of the test control operation. Real time test data is made available to the computer through time-sharing terminals at appropriate time intervals. A mathematical model of the test article and environmental control equipment is then operated on using the real time data to yield current thermal status, temperature analysis, trend prediction and recommended thermal control setting changes to arrive at the required thermal condition. The data acquisition interface and the time-sharing hook-up to an IBM-370 computer is described along with a typical control program and data demonstrating its use.
Rupp, Kimberly A; Herman, Daniel C; Hertel, Jay; Saliba, Susan A
2012-08-01
Crossover. To compare the time required to decrease intramuscular temperature 8°C below baseline temperature, and to compare intramuscular temperature 90 minutes posttreatment, between 2 cryotherapy modalities. Cryotherapy is used to treat pain from muscle injuries. Cooler intramuscular temperatures may reduce cellular metabolism and secondary hypoxic injury to attenuate acute injury response, specifically the rate of chemical mediator activity. Modalities that decrease intramuscular temperature quickly may be beneficial in the treatment of muscle injuries. Eighteen healthy subjects received 2 cryotherapy conditions, crushed-ice bag (CIB) and cold-water immersion (CWI), in a randomly allocated order, separated by 72 hours. Each condition was applied until intramuscular temperature decreased 8°C below baseline. Intramuscular temperature was monitored in the gastrocnemius, 1 cm below subcutaneous adipose tissue. The primary outcome was time to decrease intramuscular temperature 8°C below baseline. A secondary outcome was intramuscular temperature at the end of a 90-minute rewarming period. Paired t tests were used to examine outcomes. Time to reach an 8°C reduction in intramuscular temperature was not significantly different between CIB and CWI (mean difference, 2.6 minutes; 95% confidence interval: -3.10, 8.30). Intramuscular temperature remained significantly colder 90 minutes post-CWI compared to CIB (mean difference, 2.8°C; 95% confidence interval: 2.07°C, 3.52°C). There was no difference in time required to reduce intramuscular temperature 8°C 1 cm below adipose tissue using CIB and CWI. However, intramuscular temperature remained significantly colder 90 minutes following CWI. These results provide clinicians with information that may guide treatment-modality decisions.
Temporal properties of the myopic response to defocus in the guinea pig.
Leotta, Amelia J; Bowrey, Hannah E; Zeng, Guang; McFadden, Sally A
2013-05-01
Hyperopic defocus induces myopia in all species tested and is believed to underlie the progression of human myopia. We determined the temporal properties of the effects of hyperopic defocus in a mammalian eye. In Experiment 1, the rise and decay time of the responses elicited by hyperopic defocus were calculated in 111 guinea pigs by giving repeated episodes of monocular -4 D lens wear (from 5 to 6 days of age for 12 days) interspersed with various dark intervals. In Experiment 2, the decay time constant was calculated in 152 guinea pigs when repeated periods of monocular -5 D lens-wear (from 4 days of age for 7 days) were interrupted with free viewing periods of different lengths. At the end of the lens-wear period, ocular parameters were measured and time constants were calculated relative to the maximum response induced by continuous lens wear. When hyperopic defocus was experienced with dark intervals between episodes, the time required to induce 50% of the maximum achievable myopia and ocular elongation was at most 30 min. Saturated 1 h episodes took at least 22 h for refractive error and 31 h for ocular length, to decay to 50% of the maximum response. However, the decay was an order of magnitude faster when hyperopic defocus episodes were interrupted with a daily free viewing period, with only 36 min required to reduce relative myopia and ocular elongation by 50%. Hyperopic defocus causes myopia with brief exposures and is very long lasting in the absence of competing signals. However, this myopic response rapidly decays if interrupted by periods of 'normal viewing' at least 30 min in length, wherein ocular growth appears to be guided preferentially by the least amount of hyperopic defocus experienced. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
NASA Astrophysics Data System (ADS)
Rebolledo, M. A.; Martinez-Betorz, J. A.
1989-04-01
In this paper the accuracy in the determination of the period of an oscillating signal, when obtained from the photon statistics time-interval probability, is studied as a function of the precision (the inverse of the cutoff frequency of the photon counting system) with which time intervals are measured. The results are obtained by means of an experiment with a square-wave signal, where the Fourier or square-wave transforms of the time-interval probability are measured. It is found that for values of the frequency of the signal near the cutoff frequency the errors in the period are small.
Bester, Rachelle; Jooste, Anna E C; Maree, Hans J; Burger, Johan T
2012-09-27
Grapevine leafroll-associated virus 3 (GLRaV-3) is the main contributing agent of leafroll disease worldwide. Four of the six GLRaV-3 variant groups known have been found in South Africa, but their individual contribution to leafroll disease is unknown. In order to study the pathogenesis of leafroll disease, a sensitive and accurate diagnostic assay is required that can detect different variant groups of GLRaV-3. In this study, a one-step real-time RT-PCR, followed by high-resolution melting (HRM) curve analysis for the simultaneous detection and identification of GLRaV-3 variants of groups I, II, III and VI, was developed. A melting point confidence interval for each variant group was calculated to include at least 90% of all melting points observed. A multiplex RT-PCR protocol was developed to these four variant groups in order to assess the efficacy of the real-time RT-PCR HRM assay. A universal primer set for GLRaV-3 targeting the heat shock protein 70 homologue (Hsp70h) gene of GLRaV-3 was designed that is able to detect GLRaV-3 variant groups I, II, III and VI and differentiate between them with high-resolution melting curve analysis. The real-time RT-PCR HRM and the multiplex RT-PCR were optimized using 121 GLRaV-3 positive samples. Due to a considerable variation in melting profile observed within each GLRaV-3 group, a confidence interval of above 90% was calculated for each variant group, based on the range and distribution of melting points. The intervals of groups I and II could not be distinguished and a 95% joint confidence interval was calculated for simultaneous detection of group I and II variants. An additional primer pair targeting GLRaV-3 ORF1a was developed that can be used in a subsequent real-time RT-PCR HRM to differentiate between variants of groups I and II. Additionally, the multiplex RT-PCR successfully validated 94.64% of the infections detected with the real-time RT-PCR HRM. The real-time RT-PCR HRM provides a sensitive, automated and rapid tool to detect and differentiate different variant groups in order to study the epidemiology of leafroll disease.
Central tendency effects in time interval reproduction in autism
Karaminis, Themelis; Cicchini, Guido Marco; Neil, Louise; Cappagli, Giulia; Aagten-Murphy, David; Burr, David; Pellicano, Elizabeth
2016-01-01
Central tendency, the tendency of judgements of quantities (lengths, durations etc.) to gravitate towards their mean, is one of the most robust perceptual effects. A Bayesian account has recently suggested that central tendency reflects the integration of noisy sensory estimates with prior knowledge representations of a mean stimulus, serving to improve performance. The process is flexible, so prior knowledge is weighted more heavily when sensory estimates are imprecise, requiring more integration to reduce noise. In this study we measure central tendency in autism to evaluate a recent theoretical hypothesis suggesting that autistic perception relies less on prior knowledge representations than typical perception. If true, autistic children should show reduced central tendency than theoretically predicted from their temporal resolution. We tested autistic and age- and ability-matched typical children in two child-friendly tasks: (1) a time interval reproduction task, measuring central tendency in the temporal domain; and (2) a time discrimination task, assessing temporal resolution. Central tendency reduced with age in typical development, while temporal resolution improved. Autistic children performed far worse in temporal discrimination than the matched controls. Computational simulations suggested that central tendency was much less in autistic children than predicted by theoretical modelling, given their poor temporal resolution. PMID:27349722
NASA Astrophysics Data System (ADS)
Atemkeng, M.; Smirnov, O.; Tasse, C.; Foster, G.; Keimpema, A.; Paragi, Z.; Jonas, J.
2018-07-01
Traditional radio interferometric correlators produce regular-gridded samples of the true uv-distribution by averaging the signal over constant, discrete time-frequency intervals. This regular sampling and averaging then translate to be irregular-gridded samples in the uv-space, and results in a baseline-length-dependent loss of amplitude and phase coherence, which is dependent on the distance from the image phase centre. The effect is often referred to as `decorrelation' in the uv-space, which is equivalent in the source domain to `smearing'. This work discusses and implements a regular-gridded sampling scheme in the uv-space (baseline-dependent sampling) and windowing that allow for data compression, field-of-interest shaping, and source suppression. The baseline-dependent sampling requires irregular-gridded sampling in the time-frequency space, i.e. the time-frequency interval becomes baseline dependent. Analytic models and simulations are used to show that decorrelation remains constant across all the baselines when applying baseline-dependent sampling and windowing. Simulations using MeerKAT telescope and the European Very Long Baseline Interferometry Network show that both data compression, field-of-interest shaping, and outer field-of-interest suppression are achieved.
High resolution digital delay timer
Martin, Albert D.
1988-01-01
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay (20) provides a first output signal (24) at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits (26, 28) latch the high resolution data (24) to form a first synchronizing data set (60). A selected time interval has been preset to internal counters (142, 146, 154) and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses (32, 34) count down the counters to generate an internal pulse delayed by an interval which is functionally related to the preset time interval. A second LCD (184) corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD (74) to generate a second set of synchronizing data (76) which is complementary with the first set of synchronizing data (60) for presentation to logic circuits (64). The logic circuits (64) further delay the internal output signal (72) to obtain a proper phase relationship of an output signal (80) with the internal pulses (32, 34). The final delayed output signal (80) thereafter enables the output pulse generator (82) to produce the desired output pulse (84) at the preset time delay interval following input of the trigger pulse (10, 12).
Pierson, T.C.
2007-01-01
Dating of dynamic, young (<500 years) geomorphic landforms, particularly volcanofluvial features, requires higher precision than is possible with radiocarbon dating. Minimum ages of recently created landforms have long been obtained from tree-ring ages of the oldest trees growing on new surfaces. But to estimate the year of landform creation requires that two time corrections be added to tree ages obtained from increment cores: (1) the time interval between stabilization of the new landform surface and germination of the sampled trees (germination lag time or GLT); and (2) the interval between seedling germination and growth to sampling height, if the trees are not cored at ground level. The sum of these two time intervals is the colonization time gap (CTG). Such time corrections have been needed for more precise dating of terraces and floodplains in lowland river valleys in the Cascade Range, where significant eruption-induced lateral shifting and vertical aggradation of channels can occur over years to decades, and where timing of such geomorphic changes can be critical to emergency planning. Earliest colonizing Douglas fir (Pseudotsuga menziesii) were sampled for tree-ring dating at eight sites on lowland (<750 m a.s.l.), recently formed surfaces of known age near three Cascade volcanoes - Mount Rainier, Mount St. Helens and Mount Hood - in southwestern Washington and northwestern Oregon. Increment cores or stem sections were taken at breast height and, where possible, at ground level from the largest, oldest-looking trees at each study site. At least ten trees were sampled at each site unless the total of early colonizers was less. Results indicate that a correction of four years should be used for GLT and 10 years for CTG if the single largest (and presumed oldest) Douglas fir growing on a surface of unknown age is sampled. This approach would have a potential error of up to 20 years. Error can be reduced by sampling the five largest Douglas fir instead of the single largest. A GLT correction of 5 years should be added to the mean ring-count age of the five largest trees growing on the surface being dated, if the trees are cored at ground level. This correction would have an approximate error of ??5 years. If the trees are cored at about 1.4 m above the round surface (breast height), a CTG correction of 11 years should be added to the mean age of the five sampled trees (with an error of about ??7 years).
Mette, Christian; Grabemann, Marco; Zimmermann, Marco; Strunz, Laura; Scherbaum, Norbert; Wiltfang, Jens; Kis, Bernhard
2015-01-01
Altered time reproduction is exhibited by patients with adult attention deficit hyperactivity disorder (ADHD). It remains unclear whether memory capacity influences the ability of adults with ADHD to reproduce time intervals. We conducted a behavioral study on 30 ADHD patients who were medicated with methylphenidate, 29 unmedicated adult ADHD patients and 32 healthy controls (HCs). We assessed time reproduction using six time intervals (1 s, 4 s, 6 s, 10 s, 24 s and 60 s) and assessed memory performance using the Wechsler memory scale. The patients with ADHD exhibited lower memory performance scores than the HCs. No significant differences in the raw scores for any of the time intervals (p > .05), with the exception of the variability at the short time intervals (1 s, 4 s and 6 s) (p < .01), were found between the groups. The overall analyses failed to reveal any significant correlations between time reproduction at any of the time intervals examined in the time reproduction task and working memory performance (p > .05). We detected no findings indicating that working memory might influence time reproduction in adult patients with ADHD. Therefore, further studies concerning time reproduction and memory capacity among adult patients with ADHD must be performed to verify and replicate the present findings.
NASA Technical Reports Server (NTRS)
Leskovar, B.; Turko, B.
1977-01-01
The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.
Hippocampal activation during the recall of remote spatial memories in radial maze tasks.
Schlesiger, Magdalene I; Cressey, John C; Boublil, Brittney; Koenig, Julie; Melvin, Neal R; Leutgeb, Jill K; Leutgeb, Stefan
2013-11-01
Temporally graded retrograde amnesia is observed in human patients with medial temporal lobe lesions as well as in animal models of medial temporal lobe lesions. A time-limited role for these structures in memory recall has also been suggested by the observation that the rodent hippocampus and entorhinal cortex are activated during the retrieval of recent but not of remote memories. One notable exception is the recall of remote memories for platform locations in the water maze, which requires an intact hippocampus and results in hippocampal activation irrespective of the age of the memory. These findings raise the question whether the hippocampus is always involved in the recall of spatial memories or, alternatively, whether it might be required for procedural computations in the water maze task, such as for calculating a path to a hidden platform. We performed spatial memory testing in radial maze tasks to distinguish between these possibilities. Radial maze tasks require a choice between spatial locations on a center platform and thus have a lesser requirement for navigation than the water maze. However, we used a behavioral design in the radial maze that retained other aspects of the standard water maze task, such as the use of multiple start locations and retention testing in a single trial. Using the immediate early gene c-fos as a marker for neuronal activation, we found that all hippocampal subregions were more activated during the recall of remote compared to recent spatial memories. In areas CA3 and CA1, activation during remote memory testing was higher than in rats that were merely reexposed to the testing environment after the same time interval. Conversely, Fos levels in the dentate gyrus were increased after retention testing to the extent that was also observed in the corresponding exposure control group. This pattern of hippocampal activation was also obtained in a second version of the task that only used a single start arm instead of multiple start arms. The CA3 and CA1 activation during remote memory recall is consistent with the interpretation that an older memory might require increased pattern completion and/or relearning after longer time intervals. Irrespective of whether the hippocampus is required for remote memory recall, the hippocampus might engage in computations that either support recall of remote memories or that update remote memories. Copyright © 2013 Elsevier Inc. All rights reserved.
Eliciting interval beliefs: An experimental study
Peeters, Ronald; Wolk, Leonard
2017-01-01
In this paper we study the interval scoring rule as a mechanism to elicit subjective beliefs under varying degrees of uncertainty. In our experiment, subjects forecast the termination time of a time series to be generated from a given but unknown stochastic process. Subjects gradually learn more about the underlying process over time and hence the true distribution over termination times. We conduct two treatments, one with a high and one with a low volatility process. We find that elicited intervals are better when subjects are facing a low volatility process. In this treatment, participants learn to position their intervals almost optimally over the course of the experiment. This is in contrast with the high volatility treatment, where subjects, over the course of the experiment, learn to optimize the location of their intervals but fail to provide the optimal length. PMID:28380020
Mind the gap: temporal discrimination and dystonia.
Sadnicka, A; Daum, C; Cordivari, C; Bhatia, K P; Rothwell, J C; Manohar, S; Edwards, M J
2017-06-01
One of the most widely studied perceptual measures of sensory dysfunction in dystonia is the temporal discrimination threshold (TDT) (the shortest interval at which subjects can perceive that there are two stimuli rather than one). However the elevated thresholds described may be due to a number of potential mechanisms as current paradigms test not only temporal discrimination but also extraneous sensory and decision-making parameters. In this study two paradigms designed to better quantify temporal processing are presented and a decision-making model is used to assess the influence of decision strategy. 22 patients with cervical dystonia and 22 age-matched controls completed two tasks (i) temporal resolution (a randomized, automated version of existing TDT paradigms) and (ii) interval discrimination (rating the length of two consecutive intervals). In the temporal resolution task patients had delayed (P = 0.021) and more variable (P = 0.013) response times but equivalent discrimination thresholds. Modelling these effects suggested this was due to an increased perceptual decision boundary in dystonia with patients requiring greater evidence before committing to decisions (P = 0.020). Patient performance on the interval discrimination task was normal. Our work suggests that previously observed abnormalities in TDT may not be due to a selective sensory deficit of temporal processing as decision-making itself is abnormal in cervical dystonia. © 2017 EAN.
Nath, Cheryl D; Dattaraja, H S; Suresh, H S; Joshi, N V; Sukumar, R
2006-12-01
Tree diameter growth is sensitive to environmental fluctuations and tropical dry forests experience high seasonal and inter-annual environmental variation. Tree growth rates in a large permanent plot at Mudumalai, southern India, were examined for the influences of rainfall and three intrinsic factors (size, species and growth form) during three 4-year intervals over the period 1988-2000. Most trees had lowest growth during the second interval when rainfall was lowest, and skewness and kurtosis of growth distributions were reduced during this interval. Tree diameter generally explained less than 10% of growth variation and had less influence on growth than species identity or time interval. Intraspecific variation was high, yet species identity accounted for up to 16% of growth variation in the community. There were no consistent differences between canopy and understory tree growth rates; however, a few subgroups of species may potentially represent canopy and understory growth guilds. Environmentally-induced temporal variations in growth generally did not reduce the odds of subsequent survival. Growth rates appear to be strongly influenced by species identity and environmental variability in the Mudumalai dry forest. Understanding and predicting vegetation dynamics in the dry tropics thus also requires information on temporal variability in local climate.
Horr, Ninja K.; Di Luca, Massimiliano
2015-01-01
In this work we investigate how judgments of perceived duration are influenced by the properties of the signals that define the intervals. Participants compared two auditory intervals that could be any combination of the following four types: intervals filled with continuous tones (filled intervals), intervals filled with regularly-timed short tones (isochronous intervals), intervals filled with irregularly-timed short tones (anisochronous intervals), and intervals demarcated by two short tones (empty intervals). Results indicate that the type of intervals to be compared affects discrimination performance and induces distortions in perceived duration. In particular, we find that duration judgments are most precise when comparing two isochronous and two continuous intervals, while the comparison of two anisochronous intervals leads to the worst performance. Moreover, we determined that the magnitude of the distortions in perceived duration (an effect akin to the filled duration illusion) is higher for tone sequences (no matter whether isochronous or anisochronous) than for continuous tones. Further analysis of how duration distortions depend on the type of filling suggests that distortions are not only due to the perceived duration of the two individual intervals, but they may also be due to the comparison of two different filling types. PMID:25717310
NASA Astrophysics Data System (ADS)
Lucas, Charles E.; Walters, Eric A.; Jatskevich, Juri; Wasynczuk, Oleg; Lamm, Peter T.
2003-09-01
In this paper, a new technique useful for the numerical simulation of large-scale systems is presented. This approach enables the overall system simulation to be formed by the dynamic interconnection of the various interdependent simulations, each representing a specific component or subsystem such as control, electrical, mechanical, hydraulic, or thermal. Each simulation may be developed separately using possibly different commercial-off-the-shelf simulation programs thereby allowing the most suitable language or tool to be used based on the design/analysis needs. These subsystems communicate the required interface variables at specific time intervals. A discussion concerning the selection of appropriate communication intervals is presented herein. For the purpose of demonstration, this technique is applied to a detailed simulation of a representative aircraft power system, such as that found on the Joint Strike Fighter (JSF). This system is comprised of ten component models each developed using MATLAB/Simulink, EASY5, or ACSL. When the ten component simulations were distributed across just four personal computers (PCs), a greater than 15-fold improvement in simulation speed (compared to the single-computer implementation) was achieved.
Use of precision time and time interval (PTTI)
NASA Technical Reports Server (NTRS)
Taylor, J. D.
1974-01-01
A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.
NASA Astrophysics Data System (ADS)
Tarduno, John; Bono, Richard; Cottrell, Rory
2015-04-01
Recent estimates of core thermal conductivity are larger than prior values by a factor of approximately three. These new estimates suggest that the inner core is a relatively young feature, perhaps as young as 500 million years old, and that the core-mantle heat flux required to drive the early dynamo was greater than previously assumed (Nimmo, 2015). Here, we focus on paleomagnetic studies of two key time intervals important for understanding core evolution in light of the revisions of core conductivity values. 1. Hadean to Paleoarchean (4.4-3.4 Ga). Single silicate crystal paleointensity analyses suggest a relatively strong magnetic field at 3.4-3.45 Ga (Tarduno et al., 2010). Paleointenity data from zircons of the Jack Hills (Western Australia) further suggest the presence of a geodynamo between 3.5 and 3.6 Ga (Tarduno and Cottrell, 2014). We will discuss our efforts to test for the absence/presence of the geodynamo in older Eoarchean and Hadean times. 2. Ediacaran to Early Cambrian (~635-530 Ma). Disparate directions seen in some paleomagnetic studies from this time interval have been interpreted as recording inertial interchange true polar wander (IITPW). Recent single silicate paleomagnetic analyses fail to find evidence for IITPW; instead a reversing field overprinted by secondary magnetizations is defined (Bono and Tarduno, 2015). Preliminary analyses suggest the field may have been unusually weak. We will discuss our on-going tests of the hypothesis that this interval represents the time of onset of inner core growth. References: Bono, R.K. & Tarduno, J.A., Geology, in press (2015); Nimmo, F., Treatise Geophys., in press (2015); Tarduno, J.A., et al., Science (2010); Tarduno, J.A. & Cottrell, R.D., AGU Fall Meeting (2014).
Sarridou, Despoina G; Chalmouki, Georgia; Braoudaki, Maria; Koutsoupaki, Anna; Mela, Argiro; Vadalouka, Athina
2015-01-01
Up until now, the optimal strategy for postoperative pain management after total knee arthroplasty (TKA) remains to be elucidated. The current investigation aimed to examine the analgesic efficacy and the opioid sparing effects of intravenous parecoxib in combination with continuous femoral blockade. Randomized, double-blind, prospective trial. University hospital in the United Kingdom. In total, 90 patients underwent TKA under subarachnoid anesthesia and received continuous femoral block initially as a bolus with 20 mL of ropivacaine 0.75%. Infusion of 0.2% on 10 mL/h followed. Patients were randomized into 2 groups. Group D and Group P received parecoxib and placebo, respectively at 12 hour time intervals. Visual analog scale (VAS) pain scores were obtained at different time intervals including 4, 8, 12, 24 and 36 hours. The pain scores were measured with patients in a resting position. Morphine could also be administered with a patient controlled analgesia (PCA) pump if the specified analgesia was deemed inadequate (VAS > 5). None of the patients were withdrawn from the study. Parecoxib provided greater relief than placebo following TKA. The VAS pain scores measured at rest were statistically significantly lower in parecoxib-treated patients compared to the placebo group (P = 0.007) at 4 (P = 0.044), 12 (P = 0.001), and 24 hours (P = 0.012), postoperatively. Patients receiving parecoxib consumed less morphine at all time intervals than patients receiving placebo, with borderline statistical significance (P = 0.054). In each time period, all patients receiving continuous femoral block irrespectively of the treatment group, required low morphine doses. Current protocol did not answer question as to functional recovery. According to our findings intravenous parecoxib in combination with continuous femoral block provided superior analgesic efficacy and opioid sparing effects in patients undergoing TKA.
Timing of repetition suppression of event-related potentials to unattended objects.
Stefanics, Gabor; Heinzle, Jakob; Czigler, István; Valentini, Elia; Stephan, Klaas Enno
2018-05-26
Current theories of object perception emphasize the automatic nature of perceptual inference. Repetition suppression (RS), the successive decrease of brain responses to repeated stimuli, is thought to reflect the optimization of perceptual inference through neural plasticity. While functional imaging studies revealed brain regions that show suppressed responses to the repeated presentation of an object, little is known about the intra-trial time course of repetition effects to everyday objects. Here we used event-related potentials (ERP) to task-irrelevant line-drawn objects, while participants engaged in a distractor task. We quantified changes in ERPs over repetitions using three general linear models (GLM) that modelled RS by an exponential, linear, or categorical "change detection" function in each subject. Our aim was to select the model with highest evidence and determine the within-trial time-course and scalp distribution of repetition effects using that model. Model comparison revealed the superiority of the exponential model indicating that repetition effects are observable for trials beyond the first repetition. Model parameter estimates revealed a sequence of RS effects in three time windows (86-140ms, 322-360ms, and 400-446ms) and with occipital, temporo-parietal, and fronto-temporal distribution, respectively. An interval of repetition enhancement (RE) was also observed (320-340ms) over occipito-temporal sensors. Our results show that automatic processing of task-irrelevant objects involves multiple intervals of RS with distinct scalp topographies. These sequential intervals of RS and RE might reflect the short-term plasticity required for optimization of perceptual inference and the associated changes in prediction errors (PE) and predictions, respectively, over stimulus repetitions during automatic object processing. This article is protected by copyright. All rights reserved. © 2018 The Authors European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd.
Time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems.
Matityahu, Amir; Elliott, Iain; Marmor, Meir; Caldwell, Amber; Coughlin, Richard; Gosselin, Richard A
2014-01-01
To investigate the use of time intervals in the treatment of fractured femurs as indicators of the quality of trauma systems. Time intervals from injury to admission, admission to surgery and surgery to discharge for patients with isolated femur fractures in four low- and middle-income countries were compared with the corresponding values from one German hospital, an Israeli hospital and the National Trauma Data Bank of the United States of America by means of Student's t-tests. The correlations between the time intervals recorded in a country and that country's expenditure on health and gross domestic product (GDP) were also evaluated using Pearson's product moment correlation coefficient. Relative to patients from high-income countries, those from low- and middle-income countries were significantly more likely to be male and to have been treated by open femoral nailing, and their intervals from injury to admission, admission to surgery and surgery to discharge were significantly longer. Strong negative correlations were detected between the interval from injury to admission and government expenditure on health, and between the interval from admission to surgery and the per capita values for total expenditure on health, government expenditure on health and GDP. Strong positive correlations were detected between the interval from surgery to discharge and general government expenditure on health. The time intervals for the treatment of femur fractures are relatively long in low- and middle-income countries, can easily be measured, and are highly correlated with accessible and quantifiable country data on health and economics.
Dispatcher assistance and automated external defibrillator performance among elders.
Ecker, R; Rea, T D; Meischke, H; Schaeffer, S M; Kudenchuk, P; Eisenberg, M S
2001-10-01
Automated external defibrillators (AEDs) provide an opportunity to improve survival in out-of-hospital, ventricular fibrillation (VF) cardiac arrest by enabling laypersons not trained in rhythm recognition to deliver lifesaving therapy. The potential role of emergency dispatchers in the layperson use of AEDs is uncertain. This study was performed to examine whether dispatcher telephone assistance affected AED skill performance during a simulated VF cardiac arrest among a cohort of older adults. The hypothesis was that dispatcher assistance would increase the proportion who were able to correctly deliver a shock, but might require additional time. One hundred fifty community-dwelling persons aged 58-84 years were recruited from eight senior centers in King County, Washington. All participants had received AED training approximately six months previously. For this study, the participants were randomized to AED operation with or without dispatcher assistance during a simulated VF cardiac arrest. The proportions who successfully delivered a shock and the time intervals from collapse to shock were compared between the two groups. The participants who received dispatcher assistance were more likely to correctly deliver a shock with the AED during the simulated VF cardiac arrest (91% vs 68%, p = 0.001). Among those who were able to deliver a shock, the participants who received dispatcher assistance required a longer time interval from collapse to shock [median (25th, 75th percentile) = 193 seconds (165, 225) for dispatcher assistance, and 148 seconds (138, 166) for no dispatcher assistance, p = 0.001]. Among older laypersons previously trained in AED operation, dispatcher assistance may increase the proportion who can successfully deliver a shock during a VF cardiac arrest.
Lock-and-key mechanisms of cerebellar memory recall based on rebound currents.
Wetmore, Daniel Z; Mukamel, Eran A; Schnitzer, Mark J
2008-10-01
A basic question for theories of learning and memory is whether neuronal plasticity suffices to guide proper memory recall. Alternatively, information processing that is additional to readout of stored memories might occur during recall. We formulate a "lock-and-key" hypothesis regarding cerebellum-dependent motor memory in which successful learning shapes neural activity to match a temporal filter that prevents expression of stored but inappropriate motor responses. Thus, neuronal plasticity by itself is necessary but not sufficient to modify motor behavior. We explored this idea through computational studies of two cerebellar behaviors and examined whether deep cerebellar and vestibular nuclei neurons can filter signals from Purkinje cells that would otherwise drive inappropriate motor responses. In eyeblink conditioning, reflex acquisition requires the conditioned stimulus (CS) to precede the unconditioned stimulus (US) by >100 ms. In our biophysical models of cerebellar nuclei neurons this requirement arises through the phenomenon of postinhibitory rebound depolarization and matches longstanding behavioral data on conditioned reflex timing and reliability. Although CS-US intervals<100 ms may induce Purkinje cell plasticity, cerebellar nuclei neurons drive conditioned responses only if the CS-US training interval was >100 ms. This bound reflects the minimum time for deinactivation of rebound currents such as T-type Ca2+. In vestibulo-ocular reflex adaptation, hyperpolarization-activated currents in vestibular nuclei neurons may underlie analogous dependence of adaptation magnitude on the timing of visual and vestibular stimuli. Thus, the proposed lock-and-key mechanisms link channel kinetics to recall performance and yield specific predictions of how perturbations to rebound depolarization affect motor expression.
Shalev, Varda; Rogowski, Ori; Shimron, Orit; Sheinberg, Bracha; Shapira, Itzhak; Seligsohn, Uri; Berliner, Shlomo; Misgav, Mudi
2007-01-01
The incidence of stroke in patients with atrial fibrillation (AF) can be significantly reduced with warfarin therapy especially if optimally controlled. To evaluate the effect of the interval between consecutive prothrombin time measurements on the time in therapeutic range (INR 2-3) in a cohort of patients with AF on chronic warfarin treatment in the community. All INR measurements available from a relatively large cohort of patients with chronic AF were reviewed and the mean interval between consecutive INR tests of each patient was correlated with the time in therapeutic range (TTR). Altogether 251,916 INR measurements performed in 4408 patients over a period of seven years were reviewed. Sixty percent of patients had their INR measured on average every 2 to 3 weeks and most others were followed at intervals of 4 weeks or longer. A small proportion (3.6%) had their INR measured on average every week. A significant decline in the time in therapeutic range was observed as the intervals between tests increased. At one to three weeks interval the TTR was 48%, at 4 weeks interval 45% and at 5 weeks 41% (P<0.0005). A five percent increment in TTR was observed if more tests were performed at multiplications of exactly 7 days (43% vs 48% P<0.0001). A better control with an increase in the TTR was observed in patients with atrial fibrillation if prothrombin time tests are performed at regular intervals of no longer than 3 weeks.
Preventive care and recall intervals. Targeting of services in child dental care in Norway.
Wang, N J; Aspelund, G Ø
2010-03-01
Skewed caries distribution has made interesting the use of a high risk strategy in child dental services. The purpose of this study was to describe the preventive dental care given and the recall intervals used for children and adolescents in a low caries risk population, and to study how the time spent for preventive care and the length of intervals were associated with characteristics of the children and factors related to care delivery. Time spent for and type of preventive care, recall intervals, oral health and health behaviour of children and adolescents three to 18 years of age (n = 576) and the preventive services delivered were registered at routine dental examinations in the public dental services. The time used for preventive dental care was on average 22% of the total time used in a course of treatment (7.3 of 33.4 minutes). Less than 15% of the variation in time spent for prevention was explained by oral health, oral health behaviours and other characteristics of the children and the service delivery. The mean (SD) recall intervals were 15.4 (4.6) months and 55% of the children were given intervals equal to or longer than 18 months. Approximately 30% of the variation in the length of the recall intervals was explained by characteristics of the child and the service delivery. The time used for preventive dental care of children in a low risk population was standardized, while the recall intervals to a certain extent were individualized according to dental health and dental health behaviour.
Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.
Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph
2004-12-01
Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004
Cassell, S; Furst, D; Dromgoole, S; Paulus, H
1979-04-01
When the total daily drug dose was individualized to produce a steady-state serum salicylate concentration between 20 and 35 mg/dl, clinically acceptable fluctuations of serum concentrations occurred during both twice daily and three times daily administration. In 6 rheumatoid arthritis patients receiving choline magnesium trisalicylate, mean steady-state serum levels were the same, and the ranges of hourly mean concentrations during 8 and 12 hour dosage intervals were 19 to 27 mg/dl and 17 to 30 mg/dl, respectively. Changing the dosing interval from 8 to 12 hours required a 50% increase in the fractional doses, but resulted in an increase of only 3 mg/dl in mean peak concentration and a ddecrease of 1 mg/dl in mean minimum concentration.
Oral surgical handpiece use time parameters.
Roberts, Howard W; Cohen, Mark E; Murchison, David F
2005-07-01
To evaluate the clinical usage time parameters of handpieces used in oral surgical procedures. One hundred randomly selected clinical oral surgery exodontia procedures were timed to record lengths of continuous segments of both handpiece use and non-usage. Providers with experience ranging from general dentists to board certified oral surgeons were timed during surgical exodontia treatment involving 1 to 4 teeth of various complexities. Usage times were compared with manufacturers' recommendations that on times should not exceed 20 seconds in any 50-second interval (20/50 rule). Handpiece run time increased with the number of teeth and surgical case complexity (both P < .001) but was unrelated to operator experience (P = .763), in a 3-predictor model (R2 = 0.20; P < .001). Ninety-four of the 100 cases experienced at least 1 second in violation of the 20/50 rule and 42% of all run seconds were in violation. Clinicians should be aware of recommended handpiece duty use cycles. Manufacturers' recommendations about handpiece use time cycles do not reflect actual clinical usage. Under the conditions of this study, actual surgical handpiece use time was not correlated with user experience. Less experienced providers did require longer to complete treatment, but increased treatment times were due to time spent that did not require surgical handpiece use.
Meizoso, Jonathan P; Ray, Juliet J; Karcutskie, Charles A; Allen, Casey J; Zakrison, Tanya L; Pust, Gerd D; Koru-Sengul, Tulay; Ginzburg, Enrique; Pizano, Louis R; Schulman, Carl I; Livingstone, Alan S; Proctor, Kenneth G; Namias, Nicholas
2016-10-01
Timely hemorrhage control is paramount in trauma; however, a critical time interval from emergency department arrival to operation for hypotensive gunshot wound (GSW) victims is not established. We hypothesize that delaying surgery for more than 10 minutes from arrival increases all-cause mortality in hypotensive patients with GSW. Data of adults (n = 309) with hypotension and GSW to the torso requiring immediate operation from January 2004 to September 2013 were retrospectively reviewed. Patients with resuscitative thoracotomies, traumatic brain injury, transfer from outside institutions, and operations occurring more than 1 hour after arrival were excluded. Survival analysis using multivariate Cox regression models was used for comparison. Hazard ratios (HRs) and 95% confidence intervals (CIs) are reported. Statistical significance was considered at p ≤ 0.05. The study population was aged 32 ± 12 years, 92% were male, Injury Severity Score was 24 ± 15, systolic blood pressure was 81 ± 29 mm Hg, Glasgow Coma Scale score was 13 ± 4. Overall mortality was 27%. Mean time to operation was 19 ± 13 minutes. After controlling for organ injury, patients who arrived to the operating room after 10 minutes had a higher likelihood of mortality compared with those who arrived in 10 minutes or less (HR, 1.89; 95% CI, 1.10-3.26; p = 0.02); this was also true in the severely hypotensive patients with systolic blood pressure of 70 mm Hg or less (HR, 2.67; 95% CI, 0.97-7.34; p = 0.05). The time associated with a 50% cumulative mortality was 16 minutes. Delay to the operating room of more than 10 minutes increases the risk of mortality by almost threefold in hypotensive patients with GSW. Protocols should be designed to shorten time in the emergency department. Further prospective observational studies are required to validate these findings. Therapeutic study, level IV.
Stephens, Christopher B; Spackman, Erica
2017-09-15
Removal of contaminated material from a poultry house during recovery from an avian influenza virus (AIV) outbreak is costly and labor intensive. Because AIV is not environmentally stable, heating poultry houses may provide an alternative disinfection method. The objective was to determine the time necessary to inactivate AIV in poultry litter at temperatures achievable in a poultry house. Low pathogenic (LP) AIV inactivation was evaluated between 10.0°-48.9°C, at ∼5.5°C intervals and highly pathogenic (HP) AIV inactivation was evaluated between 10.0°-43.3°C, at ∼11°C intervals. Samples were collected at numerous time points for each temperature. Virus isolation in embryonating chicken eggs was conducted to determine if viable virus was present. Each sample was also tested by real-time RT-PCR. Low pathogenicity AIV was inactivated at 1day at 26.7°C or above. At 10.0, 15.6 and 21.1°C, inactivation times increased to 2-5days. Highly pathogenic AIV followed a similar trend; the virus was inactivated after 1day at 43.3°C and 32.2°C, and required 2 and 5days for inactivation at 21.1°C and 10.0°C respectively. While low pathogenicity AIV appeared to be inactivated at a lower temperature than high pathogenicity AIV, this was not due to any difference in the strains, but due to fewer temperature points being evaluated for high pathogenicity. Endpoints for detection by real-time RT-PCR were not found even weeks after the virus was inactivated. This provides a guideline for the time required, at specific temperatures to inactivate AIV in poultry litter and likely on surfaces within the house. Heat treatment will provide an added level of safety to personnel and against further spread by eliminating infectious virus prior to cleaning a house. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Bierwage, A.; Todo, Y.
2017-11-01
The transport of fast ions in a beam-driven JT-60U tokamak plasma subject to resonant magnetohydrodynamic (MHD) mode activity is simulated using the so-called multi-phase method, where 4 ms intervals of classical Monte-Carlo simulations (without MHD) are interlaced with 1 ms intervals of hybrid simulations (with MHD). The multi-phase simulation results are compared to results obtained with continuous hybrid simulations, which were recently validated against experimental data (Bierwage et al., 2017). It is shown that the multi-phase method, in spite of causing significant overshoots in the MHD fluctuation amplitudes, accurately reproduces the frequencies and positions of the dominant resonant modes, as well as the spatial profile and velocity distribution of the fast ions, while consuming only a fraction of the computation time required by the continuous hybrid simulation. The present paper is limited to low-amplitude fluctuations consisting of a few long-wavelength modes that interact only weakly with each other. The success of this benchmark study paves the way for applying the multi-phase method to the simulation of Abrupt Large-amplitude Events (ALE), which were seen in the same JT-60U experiments but at larger time intervals. Possible implications for the construction of reduced models for fast ion transport are discussed.
Ramadan, Ahmed; Boss, Connor; Choi, Jongeun; Peter Reeves, N; Cholewicki, Jacek; Popovich, John M; Radcliffe, Clark J
2018-07-01
Estimating many parameters of biomechanical systems with limited data may achieve good fit but may also increase 95% confidence intervals in parameter estimates. This results in poor identifiability in the estimation problem. Therefore, we propose a novel method to select sensitive biomechanical model parameters that should be estimated, while fixing the remaining parameters to values obtained from preliminary estimation. Our method relies on identifying the parameters to which the measurement output is most sensitive. The proposed method is based on the Fisher information matrix (FIM). It was compared against the nonlinear least absolute shrinkage and selection operator (LASSO) method to guide modelers on the pros and cons of our FIM method. We present an application identifying a biomechanical parametric model of a head position-tracking task for ten human subjects. Using measured data, our method (1) reduced model complexity by only requiring five out of twelve parameters to be estimated, (2) significantly reduced parameter 95% confidence intervals by up to 89% of the original confidence interval, (3) maintained goodness of fit measured by variance accounted for (VAF) at 82%, (4) reduced computation time, where our FIM method was 164 times faster than the LASSO method, and (5) selected similar sensitive parameters to the LASSO method, where three out of five selected sensitive parameters were shared by FIM and LASSO methods.
Purely temporal figure-ground segregation.
Kandil, F I; Fahle, M
2001-05-01
Visual figure-ground segregation is achieved by exploiting differences in features such as luminance, colour, motion or presentation time between a figure and its surround. Here we determine the shortest delay times required for figure-ground segregation based on purely temporal features. Previous studies usually employed stimulus onset asynchronies between figure- and ground-containing possible artefacts based on apparent motion cues or on luminance differences. Our stimuli systematically avoid these artefacts by constantly showing 20 x 20 'colons' that flip by 90 degrees around their midpoints at constant time intervals. Colons constituting the background flip in-phase whereas those constituting the target flip with a phase delay. We tested the impact of frequency modulation and phase reduction on target detection. Younger subjects performed well above chance even at temporal delays as short as 13 ms, whilst older subjects required up to three times longer delays in some conditions. Figure-ground segregation can rely on purely temporal delays down to around 10 ms even in the absence of luminance and motion artefacts, indicating a temporal precision of cortical information processing almost an order of magnitude lower than the one required for some models of feature binding in the visual cortex [e.g. Singer, W. (1999), Curr. Opin. Neurobiol., 9, 189-194]. Hence, in our experiment, observers are unable to use temporal stimulus features with the precision required for these models.
Application of Millisecond Pulsar Timing to the Long-Term Stability of Clock Ensembles
NASA Technical Reports Server (NTRS)
Foster, Roger S.; Matsakis, Demetrios N.
1996-01-01
We review the application of millisecond pulsars to define a precise long-term standard and positional reference system in a nearly inertial reference frame. We quantify the current timing precision of the best millisecond pulsars and define the required precise time and time interval (PTTI) accuracy and stability to enable time transfer via pulsars. Pulsars may prove useful as independent standards to examine decade-long timing stability and provide an independent natural system within which to calibrate any new, perhaps vastly improved atomic time scale. Since pulsar stability appears to be related to the lifetime of the pulsar, the new millisecond pulsar J173+0747 is projected to have a 100-day accuracy equivalent to a single HP5071 cesium standard. Over the last five years, dozens of new millisecond pulsars have been discovered. A few of the new millisecond pulsars may have even better timing properties.
NASA Astrophysics Data System (ADS)
Laban, Shaban; El-Desouky, Aly
2013-04-01
The monitoring of real-time systems is a challenging and complicated process. So, there is a continuous need to improve the monitoring process through the use of new intelligent techniques and algorithms for detecting exceptions, anomalous behaviours and generating the necessary alerts during the workflow monitoring of such systems. The interval-based or period-based theorems have been discussed, analysed, and used by many researches in Artificial Intelligence (AI), philosophy, and linguistics. As explained by Allen, there are 13 relations between any two intervals. Also, there have also been many studies of interval-based temporal reasoning and logics over the past decades. Interval-based theorems can be used for monitoring real-time interval-based data processing. However, increasing the number of processed intervals makes the implementation of such theorems a complex and time consuming process as the relationships between such intervals are increasing exponentially. To overcome the previous problem, this paper presents a Rule-based Interval State Machine Algorithm (RISMA) for processing, monitoring, and analysing the behaviour of interval-based data, received from real-time sensors. The proposed intelligent algorithm uses the Interval State Machine (ISM) approach to model any number of interval-based data into well-defined states as well as inferring them. An interval-based state transition model and methodology are presented to identify the relationships between the different states of the proposed algorithm. By using such model, the unlimited number of relationships between similar large numbers of intervals can be reduced to only 18 direct relationships using the proposed well-defined states. For testing the proposed algorithm, necessary inference rules and code have been designed and applied to the continuous data received in near real-time from the stations of International Monitoring System (IMS) by the International Data Centre (IDC) of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO). The CLIPS expert system shell has been used as the main rule engine for implementing the algorithm rules. Python programming language and the module "PyCLIPS" are used for building the necessary code for algorithm implementation. More than 1.7 million intervals constitute the Concise List of Frames (CLF) from 20 different seismic stations have been used for evaluating the proposed algorithm and evaluating stations behaviour and performance. The initial results showed that proposed algorithm can help in better understanding of the operation and performance of those stations. Different important information, such as alerts and some station performance parameters, can be derived from the proposed algorithm. For IMS interval-based data and at any period of time it is possible to analyze station behavior, determine the missing data, generate necessary alerts, and to measure some of station performance attributes. The details of the proposed algorithm, methodology, implementation, experimental results, advantages, and limitations of this research are presented. Finally, future directions and recommendations are discussed.
Short communication: use of a mechanical brush by Holstein dairy cattle around parturition.
Newby, Nathalie C; Duffield, Todd F; Pearl, David L; Leslie, Ken E; LeBlanc, Stephen J; von Keyserlingk, Marina A G
2013-04-01
Grooming is a normal behavior that may contribute to relief of stress. The purpose of this study was to investigate the effect of access to a mechanical brush on auto-grooming behavior in parturient cows. The hypothesis was that cows would increase the total time spent scratching using the brush if they had access to a brush around the time of calving, whereas auto-grooming would be lower for the brush group compared with the no-brush group. The use of a mechanical brush was analyzed both in a group-housed pen (72 to 48 h before calving) and in an individual maternity pen (6h before to 6h after calving) in 16 multiparous Holstein cows. In the maternity pen, cows were randomly assigned to have access to the brush or not. The provision of a mechanical brush in the individual maternity pen did not change the amount of time spent auto-grooming but cows did use the brush before calving and after the calf was removed. Despite being housed in pens containing a brush, cows failed to use it when the calf was present. However, cows with access to a brush spent more time licking their calves in the first hour postcalving (β=8.7 min; 95% confidence interval: 1.5, 15.8) than cows that did not have access to a brush. Regardless of treatment, cows increased the time spent auto-grooming and scratching following separation of their newborn calf (β=1.4 min; 95% confidence interval: 0.46, 2.3 and β=0.07 min; 95% confidence interval: 0.02, 0.12, respectively). Further research is warranted to investigate possible benefits of mechanical brush devices at the time of calving, particularly for cows that experience difficult calving and require manual or mechanical assistance. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Identifying radiological needs of referring clinicians.
Zhang, Li; Hefke, Antje; Figiel, Jens; Schwarz, Ulrike; Rominger, Marga; Klose, Klaus Jochen
2013-06-01
To provide prospective information about quality- and satisfaction-related product features in radiology, a customer-centered approach for acquiring clinicians' requirements and their prioritizations is essential. We introduced the Kano model for the first time in radiology to obtain such information. A Kano questionnaire, consisting of pairs of questions regarding 13 clinician requirements related to computed tomography (CT), magnetic resonance imaging (MRI) access and report turnaround time (RTT), was developed and administered. Each requirement was assigned a Kano category, and its satisfaction and dissatisfaction coefficients were calculated and presented in a Kano diagram. The data were stratified based on different clinics and on staff and resident clinicians. The time interval was evaluated between the completion of an examination and the first attempt to access the report by a clinician. Consultation for modality selection and scheduling and access to CT within 24 h and RTT within 8 to 24 h were considered as must-be requirements. Access to CT within 4 h and within 8 h, access to MRI within 8 h and within 24 h, and access to RTT within 4 h were one-dimensional requirements. The extension of operation time for CT or MRI, as well as MRI access within 4 h, was considered attractive. Eight out of nine clinics considered RTT within 8 h as a must-be requirement. There were differences in responses both among different clinics and between staff and resident clinicians. Access attempts to reports by clinicians in the first 4 h after the examination completion accounted for 65 % of CTs and 49 % of MRIs.
Funke, K; Wörgötter, F
1995-01-01
1. The spike interval pattern during the light responses of 155 on- and 81 off-centre cells of the dorsal lateral geniculate nucleus (LGN) was studied in anaesthetized and paralysed cats by the use of a novel analysis. Temporally localized interval distributions were computed from a 100 ms time window, which was shifted along the time axis in 10 ms steps, resulting in a 90% overlap between two adjacent windows. For each step the interval distribution was computed inside the time window with 1 ms resolution, and plotted as a greyscale-coded pixel line orthogonal to the time axis. For visual stimulation, light or dark spots of different size and contrast were presented with different background illumination levels. 2. Two characteristic interval patterns were observed during the sustained response component of the cells. Mainly on-cells (77%) responded with multimodal interval distributions, resulting in elongated 'bands' in the 2-dimensional time window plots. In similar situations, the interval distributions for most (71%) off-cells were rather wide and featureless. In those cases where interval bands (i.e. multimodal interval distributions) were observed for off-cells (14%), they were always much wider than for the on-cells. This difference between the on- and off-cell population was independent of the background illumination and the contrast of the stimulus. Y on-cells also tended to produce wider interval bands than X on-cells. 3. For most stimulation situations the first interval band was centred around 6-9 ms, which has been called the fundamental interval; higher order bands are multiples thereof. The fundamental interval shifted towards larger sizes with decreasing stimulus contrast. Increasing stimulus size, on the other hand, resulted in a redistribution of the intervals into higher order bands, while at the same time the location of the fundamental interval remained largely unaffected. This was interpreted as an effect of the increasing surround inhibition at the geniculate level, by which individual retinal EPSPs were cancelled. A changing level of adaptation can result in a mixed shift/redistribution effect because of the changing stimulus contrast and changing level of tonic inhibition. 4. The occurrence of interval bands is not directly related to the shape of the autocorrelation function, which can be flat, weakly oscillatory or strongly oscillatory, regardless of the interval band pattern. 5. A simple computer model was devised to account for the observed cell behaviour. The model is highly robust against parameter variations.(ABSTRACT TRUNCATED AT 400 WORDS) Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 15 PMID:7562612
Understanding Preprocedure Patient Flow in IR.
Zafar, Abdul Mueed; Suri, Rajeev; Nguyen, Tran Khanh; Petrash, Carson Cope; Fazal, Zanira
2016-08-01
To quantify preprocedural patient flow in interventional radiology (IR) and to identify potential contributors to preprocedural delays. An administrative dataset was used to compute time intervals required for various preprocedural patient-flow processes. These time intervals were compared across on-time/delayed cases and inpatient/outpatient cases by Mann-Whitney U test. Spearman ρ was used to assess any correlation of the rank of a procedure on a given day and the procedure duration to the preprocedure time. A linear-regression model of preprocedure time was used to further explore potential contributing factors. Any identified reason(s) for delay were collated. P < .05 was considered statistically significant. Of the total 1,091 cases, 65.8% (n = 718) were delayed. Significantly more outpatient cases started late compared with inpatient cases (81.4% vs 45.0%; P < .001, χ(2) test). The multivariate linear regression model showed outpatient status, length of delay in arrival, and longer procedure times to be significantly associated with longer preprocedure times. Late arrival of patients (65.9%), unavailability of physicians (18.4%), and unavailability of procedure room (13.0%) were the three most frequently identified reasons for delay. The delay was multifactorial in 29.6% of cases (n = 213). Objective measurement of preprocedural IR patient flow demonstrated considerable waste and highlighted high-yield areas of possible improvement. A data-driven approach may aid efficient delivery of IR care. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Measuring Skew in Average Surface Roughness as a Function of Surface Preparation
NASA Technical Reports Server (NTRS)
Stahl, Mark T.
2015-01-01
Characterizing surface roughness is important for predicting optical performance. Better measurement of surface roughness reduces grinding saving both time and money and allows the science requirements to be better defined. In this study various materials are polished from a fine grind to a fine polish. Each sample's RMS surface roughness is measured at 81 locations in a 9x9 square grid using a Zygo white light interferometer at regular intervals during the polishing process. Each data set is fit with various standard distributions and tested for goodness of fit. We show that the skew in the RMS data changes as a function of polishing time.
Measuring discharge with ADCPs: Inferences from synthetic velocity profiles
Rehmann, C.R.; Mueller, D.S.; Oberg, K.A.
2009-01-01
Synthetic velocity profiles are used to determine guidelines for sampling discharge with acoustic Doppler current profilers (ADCPs). The analysis allows the effects of instrument characteristics, sampling parameters, and properties of the flow to be studied systematically. For mid-section measurements, the averaging time required for a single profile measurement always exceeded the 40 s usually recommended for velocity measurements, and it increased with increasing sample interval and increasing time scale of the large eddies. Similarly, simulations of transect measurements show that discharge error decreases as the number of large eddies sampled increases. The simulations allow sampling criteria that account for the physics of the flow to be developed. ?? 2009 ASCE.
Relationship between menstruation status and work conditions in Japan.
Nishikitani, Mariko; Nakao, Mutsuhiro; Tsurugano, Shinobu; Inoure, Mariko; Yano, Eiji
2017-01-01
Menstrual problems can significantly impact daily and work life. In reaction to a shrinking population, the Japanese government is encouraging more women to participate in the labor force. Actual success in achieving this aim, however, is limited. Specifically, participation in the workforce by women during their reproductive years is impacted by their health, which involves not only work conditions, but also traditional family circumstances. Therefore, it is important to further assess and gather more information about the health status of women who work during their reproductive years in Japan. Specifically, women's health can be represented by menstruation status, which is a pivotal indicator. In this study, we assessed the association between short rest periods in work intervals and menstruation and other health status indicators among female workers in Japan. Study participants were recruited from the alumnae of a university, which provided a uniform educational level. All 9864 female alumnae were asked to join the survey and 1630 (17%) accepted. The final sample of study participants ( n = 505) were aged 23-43 years, had maintained the same job status for at least 1 year, and were not shift workers, had no maternal status, and did not lack any related information. The participants were divided into two groups according to interval time, with 11 h between end of work and resumption of daily work as a benchmark. This interval time was based on EU regulations and the goal set by the government of Japan. Health outcomes included: menstrual cycle, dysmenorrhoea symptoms, anxiety regarding health, and satisfaction in terms of health. Multiple logistic regression analyses were conducted to estimate the odds ratios (ORs) and 95% confidence intervals (CIs) for health indexes in association with interval time by adjusting for confounding variables that included both psychosocial and biological factors. We compared the health status of women in the workforce with and without a sufficient interval time of 11 h/day. Workers who had a short interval time had a significantly higher prevalence of anxiety about health and dissatisfaction with their health. For menstruation status, only abnormal menstruation cycles were observed more often among workers in the short interval group than those of the long interval group. However, this association disappeared when biological confounding factors were adjusted in a multivariable regression model. Dysmenorrhea symptoms did not show a statistically significant association with short interval time. This study found a significant association between a short interval time of less than 11 h/day and subjective health indicators and the menstrual health status of women in the workforce. Menstrual health was more affected by biological factors than social psychological factors. A long work time and short interval time could increase worker anxiety and dissatisfaction and may deteriorate the menstrual cycle.
TOT measurement implemented in FPGA TDC
NASA Astrophysics Data System (ADS)
Fan, Huan-Huan; Cao, Ping; Liu, Shu-Bin; An, Qi
2015-11-01
Time measurement plays a crucial role for the purpose of particle identification in high energy physics experiments. With increasingly demanding physics goals and the development of electronics, modern time measurement systems need to meet the requirement of excellent resolution specification as well as high integrity. Based on Field Programmable Gate Arrays (FPGAs), FPGA time-to-digital converters (TDCs) have become one of the most mature and prominent time measurement methods in recent years. For correcting the time-walk effect caused by leading timing, a time-over-threshold (TOT) measurement should be added to the FPGA TDC. TOT can be obtained by measuring the interval between the signal leading and trailing edges. Unfortunately, a traditional TDC can recognize only one kind of signal edge, the leading or the trailing. Generally, to measure the interval, two TDC channels need to be used at the same time, one for leading, the other for trailing. However, this method unavoidably increases the amount of FPGA resources used and reduces the TDC's integrity. This paper presents one method of TOT measurement implemented in a Xilinx Virtex-5 FPGA. In this method, TOT measurement can be achieved using only one TDC input channel. The consumed resources and time resolution can both be guaranteed. Testing shows that this TDC can achieve resolution better than 15ps for leading edge measurement and 37 ps for TOT measurement. Furthermore, the TDC measurement dead time is about two clock cycles, which makes it good for applications with higher physics event rates. Supported by National Natural Science Foundation of China (11079003, 10979003)
Confidence intervals from single observations in forest research
Harry T. Valentine; George M. Furnival; Timothy G. Gregoire
1991-01-01
A procedure for constructing confidence intervals and testing hypothese from a single trial or observation is reviewed. The procedure requires a prior, fixed estimate or guess of the outcome of an experiment or sampling. Two examples of applications are described: a confidence interval is constructed for the expected outcome of a systematic sampling of a forested tract...
Starting Circuit For Erasable Programmable Logic Device
NASA Technical Reports Server (NTRS)
Cole, Steven W.
1990-01-01
Voltage regulator bypassed to supply starting current. Starting or "pullup" circuit supplies large inrush of current required by erasable programmable logic device (EPLD) while being turned on. Operates only during such intervals of high demand for current and has little effect any other time. Performs needed bypass, acting as current-dependent shunt connecting battery or other source of power more nearly directly to EPLD. Input capacitor of regulator removed when starting circuit installed, reducing probability of damage to transistor in event of short circuit in or across load.
Leminen, Henri; Paavonen, Jorma
2013-01-01
The symptoms of premenstrual syndrome (PMS) and premenstrual dysphoric disorder (PMDD) significantly impair daily functioning. Symptoms occur in the late luteal phase. There must be a symptom-free interval between the end of menstruation and the time of ovulation. A two-month daily rating of symptoms is required for the diagnosis. The etiology is not well-known. Premenstrual disorders do not occur in anovulatory states. Hormonal therapy suppressing ovulation and selective serotonin reuptake inhibitors (SSRIs) are effective treatments. PMS and PMDD can be successfully managed in general practice.
Costello, Rebecca B; Elin, Ronald J; Rosanoff, Andrea; Wallace, Taylor C; Guerrero-Romero, Fernando; Hruby, Adela; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha; Song, Yiqing; Van Horn, Linda V
2016-11-01
The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75-0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. © 2016 American Society for Nutrition.
Quantifying uncertainty on sediment loads using bootstrap confidence intervals
NASA Astrophysics Data System (ADS)
Slaets, Johanna I. F.; Piepho, Hans-Peter; Schmitter, Petra; Hilger, Thomas; Cadisch, Georg
2017-01-01
Load estimates are more informative than constituent concentrations alone, as they allow quantification of on- and off-site impacts of environmental processes concerning pollutants, nutrients and sediment, such as soil fertility loss, reservoir sedimentation and irrigation channel siltation. While statistical models used to predict constituent concentrations have been developed considerably over the last few years, measures of uncertainty on constituent loads are rarely reported. Loads are the product of two predictions, constituent concentration and discharge, integrated over a time period, which does not make it straightforward to produce a standard error or a confidence interval. In this paper, a linear mixed model is used to estimate sediment concentrations. A bootstrap method is then developed that accounts for the uncertainty in the concentration and discharge predictions, allowing temporal correlation in the constituent data, and can be used when data transformations are required. The method was tested for a small watershed in Northwest Vietnam for the period 2010-2011. The results showed that confidence intervals were asymmetric, with the highest uncertainty in the upper limit, and that a load of 6262 Mg year-1 had a 95 % confidence interval of (4331, 12 267) in 2010 and a load of 5543 Mg an interval of (3593, 8975) in 2011. Additionally, the approach demonstrated that direct estimates from the data were biased downwards compared to bootstrap median estimates. These results imply that constituent loads predicted from regression-type water quality models could frequently be underestimating sediment yields and their environmental impact.
Elin, Ronald J; Rosanoff, Andrea; Lutsey, Pamela L; Nielsen, Forrest H; Rodriguez-Moran, Martha
2016-01-01
The 2015 Dietary Guidelines Advisory Committee indicated that magnesium was a shortfall nutrient that was underconsumed relative to the Estimated Average Requirement (EAR) for many Americans. Approximately 50% of Americans consume less than the EAR for magnesium, and some age groups consume substantially less. A growing body of literature from animal, epidemiologic, and clinical studies has demonstrated a varied pathologic role for magnesium deficiency that includes electrolyte, neurologic, musculoskeletal, and inflammatory disorders; osteoporosis; hypertension; cardiovascular diseases; metabolic syndrome; and diabetes. Studies have also demonstrated that magnesium deficiency is associated with several chronic diseases and that a reduced risk of these diseases is observed with higher magnesium intake or supplementation. Subclinical magnesium deficiency can exist despite the presentation of a normal status as defined within the current serum magnesium reference interval of 0.75–0.95 mmol/L. This reference interval was derived from data from NHANES I (1974), which was based on the distribution of serum magnesium in a normal population rather than clinical outcomes. What is needed is an evidenced-based serum magnesium reference interval that reflects optimal health and the current food environment and population. We present herein data from an array of scientific studies to support the perspective that subclinical deficiencies in magnesium exist, that they contribute to several chronic diseases, and that adopting a revised serum magnesium reference interval would improve clinical care and public health. PMID:28140318
A system concept for gradual deployment of geostationary lightsats
NASA Astrophysics Data System (ADS)
Peters, Graham C.; Garry, James R. C.
1993-10-01
Small satellites provide an attractive option for developing countries wishing to own and operate a satellite for the first time. It is proposed that space segment capacity could be built-up in response to increasing traffic requirements by launching small satellites at intervals into a single orbital slot to form a cluster. This paper, which results from an ESA study, reviews the various system aspects which must be considered and develops a suitable approach for multi-satellite deployment and collocation. Particular attention is paid to the system and payload configuration required to achieve effective mutual sparing between the satellites' payloads as the constellation is expanded. Mission and operational aspects are examined to obtain an acceptable risk of collisions between the satellites in a single orbit slot. The complexity and cost of operations are investigated to obtain the optimum size of satellite required to satisfy different demand requirements taken from real market scenarios.
Chu, Catherine J; Chan, Arthur; Song, Dan; Staley, Kevin J; Stufflebeam, Steven M; Kramer, Mark A
2017-02-01
High frequency oscillations are emerging as a clinically important indicator of epileptic networks. However, manual detection of these high frequency oscillations is difficult, time consuming, and subjective, especially in the scalp EEG, thus hindering further clinical exploration and application. Semi-automated detection methods augment manual detection by reducing inspection to a subset of time intervals. We propose a new method to detect high frequency oscillations that co-occur with interictal epileptiform discharges. The new method proceeds in two steps. The first step identifies candidate time intervals during which high frequency activity is increased. The second step computes a set of seven features for each candidate interval. These features require that the candidate event contain a high frequency oscillation approximately sinusoidal in shape, with at least three cycles, that co-occurs with a large amplitude discharge. Candidate events that satisfy these features are stored for validation through visual analysis. We evaluate the detector performance in simulation and on ten examples of scalp EEG data, and show that the proposed method successfully detects spike-ripple events, with high positive predictive value, low false positive rate, and high intra-rater reliability. The proposed method is less sensitive than the existing method of visual inspection, but much faster and much more reliable. Accurate and rapid detection of high frequency activity increases the clinical viability of this rhythmic biomarker of epilepsy. The proposed spike-ripple detector rapidly identifies candidate spike-ripple events, thus making clinical analysis of prolonged, multielectrode scalp EEG recordings tractable. Copyright © 2016 Elsevier B.V. All rights reserved.
Chu, Catherine. J.; Chan, Arthur; Song, Dan; Staley, Kevin J.; Stufflebeam, Steven M.; Kramer, Mark A.
2017-01-01
Summary Background High frequency oscillations are emerging as a clinically important indicator of epileptic networks. However, manual detection of these high frequency oscillations is difficult, time consuming, and subjective, especially in the scalp EEG, thus hindering further clinical exploration and application. Semi-automated detection methods augment manual detection by reducing inspection to a subset of time intervals. We propose a new method to detect high frequency oscillations that co-occur with interictal epileptiform discharges. New Method The new method proceeds in two steps. The first step identifies candidate time intervals during which high frequency activity is increased. The second step computes a set of seven features for each candidate interval. These features require that the candidate event contain a high frequency oscillation approximately sinusoidal in shape, with at least three cycles, that co-occurs with a large amplitude discharge. Candidate events that satisfy these features are stored for validation through visual analysis. Results We evaluate the detector performance in simulation and on ten examples of scalp EEG data, and show that the proposed method successfully detects spike-ripple events, with high positive predictive value, low false positive rate, and high intra-rater reliability. Comparison with Existing Method The proposed method is less sensitive than the existing method of visual inspection, but much faster and much more reliable. Conclusions Accurate and rapid detection of high frequency activity increases the clinical viability of this rhythmic biomarker of epilepsy. The proposed spike-ripple detector rapidly identifies candidate spike-ripple events, thus making clinical analysis of prolonged, multielectrode scalp EEG recordings tractable. PMID:27988323
Liquid cooled approaches for high density avionics
NASA Astrophysics Data System (ADS)
Levasseur, Robert
Next-generation aircraft will require avionics that provide greater system performance in a smaller volume, a process that requires highly developed thermal management techniques. To meet this need, a liquid-cooled approach has been developed to replace the conventional air-cooled approach for high-power applications. Liquid-cooled chassis and flow-through modules have been developed to limit junction temperatures to acceptable levels. Liquid cooling also permits emergency operation after loss of coolant for longer time intervals, which is desirable for flight-critical airborne applications. Activity to date has emphasized the development of chassis and modules that support the US Department of Defense's (DoD) two-level maintenance initiative as governed by the Joint Integrated Avionics Working Group (JIAWG).
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-Ichi
2014-01-01
The purpose of this study was to evaluate the interval between the first and second operations for staged total knee arthroplasties (TKAs) in patients with bilateral knee osteoarthritis. Depending on satisfactory preoperative health status, the patients determined the timing of the second operation. We also analysed correlations between the interval and patient characteristics. Eighty-six patients with bilateral knee osteoarthritis were analysed. The mean follow-up time from the first TKA was 96 months. The side of the first TKA was chosen by the patients. The timing of the second TKA was determined by the patients, depending on their perceived ability to tolerate the additional pain and limitations to activities of daily living. The median interval between the first and second operations was 12.5 months, with a range of 2 to 113 months. In 43 (50%) patients, the interval was <12 months. There was no difference in the interval between females and males (p=0.861), and no correlation between the interval and body mass index or age. There was weak correlation between the year of the first TKA and the interval (R=-0.251, p=0.020), with the interval getting significantly shorter as the years progressed (p=0.032). The median interval between the first and second operations in patients who underwent staged TKAs for bilateral knee osteoarthritis was about 1 year. The results of the current study may help patients and physicians to plan effective treatment strategies for staged TKAs. Level II. Copyright © 2013 Elsevier B.V. All rights reserved.
Why noise is useful in functional and neural mechanisms of interval timing?
2013-01-01
Background The ability to estimate durations in the seconds-to-minutes range - interval timing - is essential for survival, adaptation and its impairment leads to severe cognitive and/or motor dysfunctions. The response rate near a memorized duration has a Gaussian shape centered on the to-be-timed interval (criterion time). The width of the Gaussian-like distribution of responses increases linearly with the criterion time, i.e., interval timing obeys the scalar property. Results We presented analytical and numerical results based on the striatal beat frequency (SBF) model showing that parameter variability (noise) mimics behavioral data. A key functional block of the SBF model is the set of oscillators that provide the time base for the entire timing network. The implementation of the oscillators block as simplified phase (cosine) oscillators has the additional advantage that is analytically tractable. We also checked numerically that the scalar property emerges in the presence of memory variability by using biophysically realistic Morris-Lecar oscillators. First, we predicted analytically and tested numerically that in a noise-free SBF model the output function could be approximated by a Gaussian. However, in a noise-free SBF model the width of the Gaussian envelope is independent of the criterion time, which violates the scalar property. We showed analytically and verified numerically that small fluctuations of the memorized criterion time leads to scalar property of interval timing. Conclusions Noise is ubiquitous in the form of small fluctuations of intrinsic frequencies of the neural oscillators, the errors in recording/retrieving stored information related to criterion time, fluctuation in neurotransmitters’ concentration, etc. Our model suggests that the biological noise plays an essential functional role in the SBF interval timing. PMID:23924391
Steiner, Markus FC; Cezard, Genevieve; Bansal, Narinder; Fischbacher, Colin; Douglas, Anne; Bhopal, Raj; Sheikh, Aziz
2015-01-01
Objective There is evidence of substantial ethnic variations in asthma morbidity and the risk of hospitalisation, but the picture in relation to lower respiratory tract infections is unclear. We carried out an observational study to identify ethnic group differences for lower respiratory tract infections. Design A retrospective, cohort study. Setting Scotland. Participants 4.65 million people on whom information was available from the 2001 census, followed from May 2001 to April 2010. Main outcome measures Hospitalisations and deaths (any time following first hospitalisation) from lower respiratory tract infections, adjusted risk ratios and hazard ratios by ethnicity and sex were calculated. We multiplied ratios and confidence intervals by 100, so the reference Scottish White population’s risk ratio and hazard ratio was 100. Results Among men, adjusted risk ratios for lower respiratory tract infection hospitalisation were lower in Other White British (80, 95% confidence interval 73–86) and Chinese (69, 95% confidence interval 56–84) populations and higher in Pakistani groups (152, 95% confidence interval 136–169). In women, results were mostly similar to those in men (e.g. Chinese 68, 95% confidence interval 56–82), although higher adjusted risk ratios were found among women of the Other South Asians group (145, 95% confidence interval 120–175). Survival (adjusted hazard ratio) following lower respiratory tract infection for Pakistani men (54, 95% confidence interval 39–74) and women (31, 95% confidence interval 18–53) was better than the reference population. Conclusions Substantial differences in the rates of lower respiratory tract infections amongst different ethnic groups in Scotland were found. Pakistani men and women had particularly high rates of lower respiratory tract infection hospitalisation. The reasons behind the high rates of lower respiratory tract infection in the Pakistani community are now required. PMID:26152675
Conservative management of extradural hematoma: A report of sixty-two cases.
Zwayed, A Rahim H; Lucke-Wold, Brandon
2018-06-01
Extradural hematomas (EDH) are considered life threatening in that the risk for brain herniation is significant. The current accepted understanding within the literature is to treat EDH via surgical evacuation of the hematoma. In this case-series we report 62 cases of EDH managed conservatively without surgical intervention. Inclusion criteria were: Glasgow comma scale score 13-15, extradural hematoma confirmed by CT being less than 40 mm, less than 6 mm of midline shift, and no other surgical lesions present. Patients were initially observed in a surgical intensive care unit prior to discharge and had closely scheduled follow-up. Of the 62 cases none required emergent intervention and the majority had interval resolution of the epidural hematoma over time. Resolution was apparent by 21 days and definitive by 3 to 6 months. Patients with EDH who have a high Glasgow comma scale score 13-15, volume <40 mm, and less than 6 mm of midline shift should be considered for conservative management. Our study indicates that these patients will have interval resolution of hematoma over time without worsening of symptoms.
The Behavioral Economics of Choice and Interval Timing
Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.
2009-01-01
We propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with the highest payoff is emitted. The model accounts for a wide range of data from procedures such as simple bisection, metacognition in animals, economic effects in free-operant psychophysical procedures and paradoxical choice in double-bisection procedures. Although it assumes logarithmic time representation, it can also account for data from the time-left procedure usually cited in support of linear time representation. It encounters some difficulties in complex free-operant choice procedures, such as concurrent mixed fixed-interval schedules as well as some of the data on double bisection, that may involve additional processes. Overall, BEM provides a theoretical framework for understanding how reinforcement and interval timing work together to determine choice between temporally differentiated reinforcers. PMID:19618985
Civil helicopter propulsion system reliability and engine monitoring technology assessments
NASA Technical Reports Server (NTRS)
Murphy, J. A.; Zuk, J.
1982-01-01
A study to reduce operating costs of helicopters, particularly directed at the maintenance of the propulsion subsystem, is presented. The tasks of the study consisted of problem definition refinement, technology solutions, diagnostic system concepts, and emergency power augmentation. Quantifiable benefits (reduced fuel consumption, on-condition engine maintenance, extended drive system overhaul periods, and longer oil change intervals) would increase the initial cost by $43,000, but the benefit of $24.46 per hour would result in breakeven at 1758 hours. Other benefits not capable of being quantified but perhaps more important include improved aircraft avilability due to reduced maintenance time, potential for increased operating limits due to continuous automatic monitoring of gages, and less time and fuel required to make engine power checks. The most important improvement is the on-condition maintenance program, which will require the development of algorithms, equipment, and procedures compatible with all operating environments.
Preemptive Deceased Donor Kidney Transplantation: Considerations of Equity and Utility
Chen, B. Po-Han; Coresh, Josef; Segev, Dorry L.
2013-01-01
Summary Background and objectives There exists gross disparity in national deceased donor kidney transplant availability and practice: waiting times exceed 6 years in some regions, but some patients receive kidneys before they require dialysis. This study aimed to quantify and characterize preemptive deceased donor kidney transplant recipients and compare their outcomes with patients transplanted shortly after dialysis initiation. Design, setting, participants, & measurements Using the Scientific Registry of Transplant Recipients database, first-time adult deceased donor kidney transplant recipients between 1995 and 2011 were classified as preemptive, early (on dialysis≤1 year), or late recipients. Random effects logistic regression and multivariate Cox proportional hazards regression were used to identify characteristics of preemptive deceased donor kidney transplant and evaluate survival in preemptive and early recipients, respectively. Results Preemptive recipients were 9.0% of the total recipient population. Patients with private insurance (adjusted odds ratio=3.15, 95% confidence interval=3.01–3.29, P<0.001), previous (nonkidney) transplant (adjusted odds ratio=1.94, 95% confidence interval=1.67–2.26, P<0.001), and zero-antigen mismatch (adjusted odds ratio=1.45, 95% confidence interval=1.37–1.54, P<0.001; Caucasians only) were more likely to receive preemptive deceased donor kidney transplant, even after accounting for center-level clustering. African Americans were less likely to receive preemptive deceased donor kidney transplant (adjusted odds ratio=0.44, 95% confidence interval=0.41–0.47, P<0.001). Overall, patients transplanted preemptively had similar survival compared with patients transplanted within 1 year after initiating dialysis (adjusted hazard ratio=1.06, 95% confidence interval=0.99–1.12, P=0.07). Conclusions Preemptive deceased donor kidney transplant occurs most often among Caucasians with private insurance, and survival is fairly similar to survival of recipients on dialysis for <1 year. PMID:23371953
Foster, Carl; Farland, Courtney V.; Guidotti, Flavia; Harbin, Michelle; Roberts, Brianna; Schuette, Jeff; Tuuri, Andrew; Doberstein, Scott T.; Porcari, John P.
2015-01-01
High intensity interval training (HIIT) has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly). Steady-state (n = 19) exercised (cycle ergometer) 20 minutes at 90% of ventilatory threshold (VT). Tabata (n = 21) completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15) completed 13 sets of 30s (20 min) @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. Results: There were significant (p < 0.05) increases in VO2max (+19, +18 and +18%) and PPO (+17, +24 and +14%) for each training group, as well as significant increases in peak (+8, + 9 and +5%) & mean (+4, +7 and +6%) power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p < 0.05) than the steady state and Meyer protocols, and that the enjoyment of all protocols declined (p < 0.05) across the duration of the study. The results suggest that although HIIT protocols are time efficient, they are not superior to conventional exercise training in sedentary young adults. Key points Steady state training equivalent to HIIT in untrained students Mild interval training presents very similar physiologic challenge compared to steady state training HIIT (particularly very high intensity variants were less enjoyable than steady state or mild interval training Enjoyment of training decreases across the course of an 8 week experimental training program PMID:26664271
Foster, Carl; Farland, Courtney V; Guidotti, Flavia; Harbin, Michelle; Roberts, Brianna; Schuette, Jeff; Tuuri, Andrew; Doberstein, Scott T; Porcari, John P
2015-12-01
High intensity interval training (HIIT) has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly). Steady-state (n = 19) exercised (cycle ergometer) 20 minutes at 90% of ventilatory threshold (VT). Tabata (n = 21) completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15) completed 13 sets of 30s (20 min) @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. There were significant (p < 0.05) increases in VO2max (+19, +18 and +18%) and PPO (+17, +24 and +14%) for each training group, as well as significant increases in peak (+8, + 9 and +5%) & mean (+4, +7 and +6%) power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p < 0.05) than the steady state and Meyer protocols, and that the enjoyment of all protocols declined (p < 0.05) across the duration of the study. The results suggest that although HIIT protocols are time efficient, they are not superior to conventional exercise training in sedentary young adults. Key pointsSteady state training equivalent to HIIT in untrained studentsMild interval training presents very similar physiologic challenge compared to steady state trainingHIIT (particularly very high intensity variants were less enjoyable than steady state or mild interval trainingEnjoyment of training decreases across the course of an 8 week experimental training program.
Quantitative analysis of ground penetrating radar data in the Mu Us Sandland
NASA Astrophysics Data System (ADS)
Fu, Tianyang; Tan, Lihua; Wu, Yongqiu; Wen, Yanglei; Li, Dawei; Duan, Jinlong
2018-06-01
Ground penetrating radar (GPR), which can reveal the sedimentary structure and development process of dunes, is widely used to evaluate aeolian landforms. The interpretations for GPR profiles are mostly based on qualitative descriptions of geometric features of the radar reflections. This research quantitatively analyzed the waveform parameter characteristics of different radar units by extracting the amplitude and time interval parameters of GPR data in the Mu Us Sandland in China, and then identified and interpreted different sedimentary structures. The results showed that different types of radar units had specific waveform parameter characteristics. The main waveform parameter characteristics of sand dune radar facies and sandstone radar facies included low amplitudes and wide ranges of time intervals, ranging from 0 to 0.25 and 4 to 33 ns respectively, and the mean amplitudes changed gradually with time intervals. The amplitude distribution curves of various sand dune radar facies were similar as unimodal distributions. The radar surfaces showed high amplitudes with time intervals concentrated in high-value areas, ranging from 0.08 to 0.61 and 9 to 34 ns respectively, and the mean amplitudes changed drastically with time intervals. The amplitude and time interval values of lacustrine radar facies were between that of sand dune radar facies and radar surfaces, ranging from 0.08 to 0.29 and 11 to 30 ns respectively, and the mean amplitude and time interval curve was approximately trapezoidal. The quantitative extraction and analysis of GPR reflections could help distinguish various radar units and provide evidence for identifying sedimentary structure in aeolian landforms.
Detection of anomalous signals in temporally correlated data (Invited)
NASA Astrophysics Data System (ADS)
Langbein, J. O.
2010-12-01
Detection of transient tectonic signals in data obtained from large geodetic networks requires the ability to detect signals that are both temporally and spatially coherent. In this report I will describe a modification to an existing method that estimates both the coefficients of temporally correlated noise model and an efficient filter based on the noise model. This filter, when applied to the original time-series, effectively whitens (or flattens) the power spectrum. The filtered data provide the means to calculate running averages which are then used to detect deviations from the background trends. For large networks, time-series of signal-to-noise ratio (SNR) can be easily constructed since, by filtering, each of the original time-series has been transformed into one that is closer to having a Gaussian distribution with a variance of 1.0. Anomalous intervals may be identified by counting the number of GPS sites for which the SNR exceeds a specified value. For example, during one time interval, if there were 5 out of 20 time-series with SNR>2, this would be considered anomalous; typically, one would expect at 95% confidence that there would be at least 1 out of 20 time-series with an SNR>2. For time intervals with an anomalously large number of high SNR, the spatial distribution of the SNR is mapped to identify the location of the anomalous signal(s) and their degree of spatial clustering. Estimating the filter that should be used to whiten the data requires modification of the existing methods that employ maximum likelihood estimation to determine the temporal covariance of the data. In these methods, it is assumed that the noise components in the data are a combination of white, flicker and random-walk processes and that they are derived from three different and independent sources. Instead, in this new method, the covariance matrix is constructed assuming that only one source is responsible for the noise and that source can be represented as a white-noise random-number generator convolved with a filter whose spectral properties are frequency (f) independent at its highest frequencies, 1/f at the middle frequencies, and 1/f2 at the lowest frequencies. For data sets with no gaps in their time-series, construction of covariance and inverse covariance matrices is extremely efficient. Application of the above algorithm to real data potentially involves several iterations as small, tectonic signals of interest are often indistinguishable from background noise. Consequently, simply plotting the time-series of each GPS site is used to identify the largest outliers and signals independent of their cause. Any analysis of the background noise levels must factor in these other signals while the gross outliers need to be removed.
Interval timing in genetically modified mice: a simple paradigm
Balci, F.; Papachristos, E. B.; Gallistel, C. R.; Brunner, D.; Gibson, J.; Shumyatsky, G. P.
2009-01-01
We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using D-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently. PMID:17696995
Interval timing in genetically modified mice: a simple paradigm.
Balci, F; Papachristos, E B; Gallistel, C R; Brunner, D; Gibson, J; Shumyatsky, G P
2008-04-01
We describe a behavioral screen for the quantitative study of interval timing and interval memory in mice. Mice learn to switch from a short-latency feeding station to a long-latency station when the short latency has passed without a feeding. The psychometric function is the cumulative distribution of switch latencies. Its median measures timing accuracy and its interquartile interval measures timing precision. Next, using this behavioral paradigm, we have examined mice with a gene knockout of the receptor for gastrin-releasing peptide that show enhanced (i.e. prolonged) freezing in fear conditioning. We have tested the hypothesis that the mutants freeze longer because they are more uncertain than wild types about when to expect the electric shock. The knockouts however show normal accuracy and precision in timing, so we have rejected this alternative hypothesis. Last, we conduct the pharmacological validation of our behavioral screen using d-amphetamine and methamphetamine. We suggest including the analysis of interval timing and temporal memory in tests of genetically modified mice for learning and memory and argue that our paradigm allows this to be done simply and efficiently.
Estimates of the maximum time required to originate life
NASA Technical Reports Server (NTRS)
Oberbeck, Verne R.; Fogleman, Guy
1989-01-01
Fossils of the oldest microorganisms exist in 3.5 billion year old rocks and there is indirect evidence that life may have existed 3.8 billion years ago (3.8 Ga). Impacts able to destroy life or interrupt prebiotic chemistry may have occurred after 3.5 Ga. If large impactors vaporized the oceans, sterilized the planets, and interfered with the origination of life, life must have originated in the time interval between these impacts which increased with geologic time. Therefore, the maximum time required for the origination of life is the time that occurred between sterilizing impacts just before 3.8 Ga or 3.5 Ga, depending upon when life first appeared on earth. If life first originated 3.5 Ga, and impacts with kinetic energies between 2 x 10 the the 34th and 2 x 10 to the 35th were able to vaporize the oceans, using the most probable impact flux, it is found that the maximum time required to originate life would have been 67 to 133 million years (My). If life originated 3.8 Ga, the maximum time to originate life was 2.5 to 11 My. Using a more conservative estimate for the flux of impacting objects before 3.8 Ga, a maximum time of 25 My was found for the same range of impactor kinetic energies. The impact model suggests that it is possible that life may have originated more than once.
Estimating short-run and long-run interaction mechanisms in interictal state.
Ozkaya, Ata; Korürek, Mehmet
2010-04-01
We address the issue of analyzing electroencephalogram (EEG) from seizure patients in order to test, model and determine the statistical properties that distinguish between EEG states (interictal, pre-ictal, ictal) by introducing a new class of time series analysis methods. In the present study: firstly, we employ statistical methods to determine the non-stationary behavior of focal interictal epileptiform series within very short time intervals; secondly, for such intervals that are deemed non-stationary we suggest the concept of Autoregressive Integrated Moving Average (ARIMA) process modelling, well known in time series analysis. We finally address the queries of causal relationships between epileptic states and between brain areas during epileptiform activity. We estimate the interaction between different EEG series (channels) in short time intervals by performing Granger-causality analysis and also estimate such interaction in long time intervals by employing Cointegration analysis, both analysis methods are well-known in econometrics. Here we find: first, that the causal relationship between neuronal assemblies can be identified according to the duration and the direction of their possible mutual influences; second, that although the estimated bidirectional causality in short time intervals yields that the neuronal ensembles positively affect each other, in long time intervals neither of them is affected (increasing amplitudes) from this relationship. Moreover, Cointegration analysis of the EEG series enables us to identify whether there is a causal link from the interictal state to ictal state.
Capability and dependency in the Newcastle 85+ cohort study. Projections of future care needs.
Jagger, Carol; Collerton, Joanna C; Davies, Karen; Kingston, Andrew; Robinson, Louise A; Eccles, Martin P; von Zglinicki, Thomas; Martin-Ruiz, Carmen; James, Oliver F W; Kirkwood, Tom B L; Bond, John
2011-05-04
Little is known of the capabilities of the oldest old, the fastest growing age group in the population. We aimed to estimate capability and dependency in a cohort of 85 year olds and to project future demand for care. Structured interviews at age 85 with 841 people born in 1921 and living in Newcastle and North Tyneside, UK who were permanently registered with participating general practices. Measures of capability included were self-reported activities of daily living (ADL), timed up and go test (TUG), standardised mini-mental state examination (SMMSE), and assessment of urinary continence in order to classify interval-need dependency. To project future demand for care the proportion needing 24-hour care was applied to the 2008 England and Wales population projections of those aged 80 years and over by gender. Of participants, 62% (522/841) were women, 77% (651/841) lived in standard housing, 13% (106/841) in sheltered housing and 10% (84/841) in a care home. Overall, 20% (165/841) reported no difficulty with any of the ADLs. Men were more capable in performing ADLs and more independent than women. TUG validated self-reported ADLs. When classified by 'interval of need' 41% (332/810) were independent, 39% (317/810) required help less often than daily, 12% (94/810) required help at regular times of the day and 8% (67/810) required 24-hour care. Of care-home residents, 94% (77/82) required daily help or 24-hour care. Future need for 24-hour care for people aged 80 years or over in England and Wales is projected to increase by 82% from 2010 to 2030 with a demand for 630,000 care-home places by 2030. This analysis highlights the diversity of capability and levels of dependency in this cohort. A remarkably high proportion remain independent, particularly men. However a significant proportion of this population require 24-hour care at home or in care homes. Projections for the next 20 years suggest substantial increases in the number requiring 24-hour care due to population ageing and a proportionate increase in demand for care-home places unless innovative health and social care interventions are found.
Mette, Christian; Grabemann, Marco; Zimmermann, Marco; Strunz, Laura; Scherbaum, Norbert; Wiltfang, Jens; Kis, Bernhard
2015-01-01
Objective Altered time reproduction is exhibited by patients with adult attention deficit hyperactivity disorder (ADHD). It remains unclear whether memory capacity influences the ability of adults with ADHD to reproduce time intervals. Method We conducted a behavioral study on 30 ADHD patients who were medicated with methylphenidate, 29 unmedicated adult ADHD patients and 32 healthy controls (HCs). We assessed time reproduction using six time intervals (1 s, 4 s, 6 s, 10 s, 24 s and 60 s) and assessed memory performance using the Wechsler memory scale. Results The patients with ADHD exhibited lower memory performance scores than the HCs. No significant differences in the raw scores for any of the time intervals (p > .05), with the exception of the variability at the short time intervals (1 s, 4 s and 6 s) (p < .01), were found between the groups. The overall analyses failed to reveal any significant correlations between time reproduction at any of the time intervals examined in the time reproduction task and working memory performance (p > .05). Conclusion We detected no findings indicating that working memory might influence time reproduction in adult patients with ADHD. Therefore, further studies concerning time reproduction and memory capacity among adult patients with ADHD must be performed to verify and replicate the present findings. PMID:26221955
Wilquin, Hélène; Delevoye-Turrell, Yvonne; Dione, Mariama; Giersch, Anne
2018-01-01
Objective: Basic temporal dysfunctions have been described in patients with schizophrenia, which may impact their ability to connect and synchronize with the outer world. The present study was conducted with the aim to distinguish between interval timing and synchronization difficulties and more generally the spatial-temporal organization disturbances for voluntary actions. A new sensorimotor synchronization task was developed to test these abilities. Method: Twenty-four chronic schizophrenia patients matched with 27 controls performed a spatial-tapping task in which finger taps were to be produced in synchrony with a regular metronome to six visual targets presented around a virtual circle on a tactile screen. Isochronous (time intervals of 500 ms) and non-isochronous auditory sequences (alternated time intervals of 300/600 ms) were presented. The capacity to produce time intervals accurately versus the ability to synchronize own actions (tap) with external events (tone) were measured. Results: Patients with schizophrenia were able to produce the tapping patterns of both isochronous and non-isochronous auditory sequences as accurately as controls producing inter-response intervals close to the expected interval of 500 and 900 ms, respectively. However, the synchronization performances revealed significantly more positive asynchrony means (but similar variances) in the patient group than in the control group for both types of auditory sequences. Conclusion: The patterns of results suggest that patients with schizophrenia are able to perceive and produce both simple and complex sequences of time intervals but are impaired in the ability to synchronize their actions with external events. These findings suggest a specific deficit in predictive timing, which may be at the core of early symptoms previously described in schizophrenia.
Zhang, Jimmy; Mannix, Rebekah; Whalen, Michael J.
2012-01-01
Abstract BACKGROUND: Although previous evidence suggests that the cognitive effects of concussions are cumulative, the effect of time interval between repeat concussions is largely unknown. OBJECTIVE: To determine the effect of time interval between repeat concussions on the cognitive function of mice. METHODS: We used a weight-drop model of concussion to subject anesthetized mice to 1, 3, 5, or 10 concussions, each a day apart. Additional mice were subjected to 5 concussions at varying time intervals: daily, weekly, and monthly. Morris water maze performance was measured 24 hours, 1 month, and 1 year after final injury. RESULTS: After 1 concussion, injured and sham-injured mice performed similarly in the Morris water maze. As the number of concussions increased, injured mice performed worse than sham-injured mice. Mice sustaining 5 concussions either 1 day or 1 week apart performed worse than sham-injured mice. When 5 concussions were delivered at 1-month time intervals, no difference in Morris water maze performance was observed between injured and sham-injured mice. After a 1-month recovery period, mice that sustained 5 concussions at daily and weekly time intervals continued to perform worse than sham-injured mice. One year after the final injury, mice sustaining 5 concussions at a daily time interval still performed worse than sham-injured mice. CONCLUSION: When delivered within a period of vulnerability, the cognitive effects of multiple concussions are cumulative, persistent, and may be permanent. Increasing the time interval between concussions attenuates the effects on cognition. When multiple concussions are sustained by mice daily, the effects on cognition are long term. PMID:22743360
Prediction Models for Dynamic Demand Response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aman, Saima; Frincu, Marc; Chelmis, Charalampos
2015-11-02
As Smart Grids move closer to dynamic curtailment programs, Demand Response (DR) events will become necessary not only on fixed time intervals and weekdays predetermined by static policies, but also during changing decision periods and weekends to react to real-time demand signals. Unique challenges arise in this context vis-a-vis demand prediction and curtailment estimation and the transformation of such tasks into an automated, efficient dynamic demand response (D 2R) process. While existing work has concentrated on increasing the accuracy of prediction models for DR, there is a lack of studies for prediction models for D 2R, which we address inmore » this paper. Our first contribution is the formal definition of D 2R, and the description of its challenges and requirements. Our second contribution is a feasibility analysis of very-short-term prediction of electricity consumption for D 2R over a diverse, large-scale dataset that includes both small residential customers and large buildings. Our third, and major contribution is a set of insights into the predictability of electricity consumption in the context of D 2R. Specifically, we focus on prediction models that can operate at a very small data granularity (here 15-min intervals), for both weekdays and weekends - all conditions that characterize scenarios for D 2R. We find that short-term time series and simple averaging models used by Independent Service Operators and utilities achieve superior prediction accuracy. We also observe that workdays are more predictable than weekends and holiday. Also, smaller customers have large variation in consumption and are less predictable than larger buildings. Key implications of our findings are that better models are required for small customers and for non-workdays, both of which are critical for D 2R. Also, prediction models require just few days’ worth of data indicating that small amounts of historical training data can be used to make reliable predictions, simplifying the complexity of big data challenge associated with D 2R.« less
Validity and Generalizability of Measuring Student Engaged Time in Physical Education.
ERIC Educational Resources Information Center
Silverman, Stephen; Zotos, Connee
The validity of interval and time sampling methods of measuring student engaged time was investigated in a study estimating the actual time students spent engaged in relevant motor performance in physical education classes. Two versions of the interval Academic Learning Time in Physical Education (ALT-PE) instrument and an equivalent time sampling…
A model of interval timing by neural integration.
Simen, Patrick; Balci, Fuat; de Souza, Laura; Cohen, Jonathan D; Holmes, Philip
2011-06-22
We show that simple assumptions about neural processing lead to a model of interval timing as a temporal integration process, in which a noisy firing-rate representation of time rises linearly on average toward a response threshold over the course of an interval. Our assumptions include: that neural spike trains are approximately independent Poisson processes, that correlations among them can be largely cancelled by balancing excitation and inhibition, that neural populations can act as integrators, and that the objective of timed behavior is maximal accuracy and minimal variance. The model accounts for a variety of physiological and behavioral findings in rodents, monkeys, and humans, including ramping firing rates between the onset of reward-predicting cues and the receipt of delayed rewards, and universally scale-invariant response time distributions in interval timing tasks. It furthermore makes specific, well-supported predictions about the skewness of these distributions, a feature of timing data that is usually ignored. The model also incorporates a rapid (potentially one-shot) duration-learning procedure. Human behavioral data support the learning rule's predictions regarding learning speed in sequences of timed responses. These results suggest that simple, integration-based models should play as prominent a role in interval timing theory as they do in theories of perceptual decision making, and that a common neural mechanism may underlie both types of behavior.
Smith, Winchell
1971-01-01
Current-meter measurements of high accuracy will be required for calibration of an acoustic flow-metering system proposed for installation in the Sacramento River at Chipps Island in California. This report presents an analysis of the problem of making continuous accurate current-meter measurements in this channel where the flow regime is changing constantly in response to tidal action. Gaging-system requirements are delineated, and a brief description is given of the several applicable techniques that have been developed by others. None of these techniques provides the accuracies required for the flowmeter calibration. A new system is described--one which has been assembled and tested in prototype and which will provide the matrix of data needed for accurate continuous current-meter measurements. Analysis of a large quantity of data on the velocity distribution in the channel of the Sacramento River at Chipps Island shows that adequate definition of the velocity can be made during the dominant flow periods--that is, at times other than slack-water periods--by use of current meters suspended at elevations 0.2 and 0.8 of the depth below the water surface. However, additional velocity surveys will be necessary to determine whether or not small systematic corrections need be applied during periods of rapidly changing flow. In the proposed system all gaged parameters, including velocities, depths, position in the stream, and related times, are monitored continuously as a boat moves across the river on the selected cross section. Data are recorded photographically and transferred later onto punchcards for computer processing. Computer programs have been written to permit computation of instantaneous discharges at any selected time interval throughout the period of the current meter measurement program. It is anticipated that current-meter traverses will be made at intervals of about one-half hour over periods of several days. Capability of performance for protracted periods was, consequently, one of the important elements in system design. Analysis of error sources in the proposed system indicates that errors in individual computed discharges can be kept smaller than 1.5 percent if the expected precision in all measured parameters is maintained.
Madison, Guy; Karampela, Olympia; Ullén, Fredrik; Holm, Linus
2013-05-01
Timing permeates everyday activities such as walking, dancing and music, yet the effect of short-term practice in this ubiquitous activity is largely unknown. In two training experiments involving sessions spread across several days, we examined short-term practice effects on timing variability in a sequential interval production task. In Experiment 1, we varied the mode of response (e.g., drumstick and finger tapping) and the level of sensory feedback. In Experiment 2 we varied the interval in 18 levels ranging from 500 ms to 1624 ms. Both experiments showed a substantial decrease in variability within the first hour of practice, but little thereafter. This effect was similar across mode of response, amount of feedback, and interval duration, and was manifested as a reduction in both local variability (between neighboring intervals) and drift (fluctuation across multiple intervals). The results suggest mainly effects on motor implementation rather than on cognitive timing processes, and have methodological implications for timing studies that have not controlled for practice. Copyright © 2013 Elsevier B.V. All rights reserved.
Provocative issues in heart disease prevention.
Juneau, Martin; Hayami, Douglas; Gayda, Mathieu; Lacroix, Sébastien; Nigam, Anil
2014-12-01
In this article, new areas of cardiovascular (CV) prevention and rehabilitation research are discussed: high-intensity interval training (HIIT) and new concepts in nutrition. HIIT consists of brief periods of high-intensity exercise interspersed by periods of low-intensity exercise or rest. The optimal mode according our work (15-second exercise intervals at peak power with passive recovery intervals of the same duration) is associated with longer total exercise time, similar time spent near peak oxygen uptake (VO2 peak) VO2 peak, and lesser perceived exertion relative to other protocols that use longer intervals and active recovery periods. Evidence also suggests that compared with moderate-intensity continuous exercise training, HIIT has superior effects on cardiorespiratory function and on the attenuation of multiple cardiac and peripheral abnormalities. With respect to nutrition, a growing body of evidence suggests that the gut microbiota is influenced by lifestyle choices and might play a pivotal role in modulating CV disease development. For example, recent evidence linking processed (but not unprocessed) meats to increased CV risk pointed to the gut microbial metabolite trimethylamine N-oxide as a potential culprit. In addition, altered gut microbiota could also mediate the proinflammatory and cardiometabolic abnormalities associated with excess added free sugar consumption, and in particular high-fructose corn syrup. Substantially more research is required, however, to fully understand how and which alterations in gut flora can prevent or lead to CV disease and other chronic illnesses. We conclude with thoughts about the appropriate role for HIIT in CV training and future research in the role of gut flora-directed interventions in CV prevention. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Dikpati, Mausumi; Anderson, Jeffrey L.; Mitra, Dhrubaditya
2016-09-01
We implement an Ensemble Kalman Filter procedure using the Data Assimilation Research Testbed for assimilating “synthetic” meridional flow-speed data in a Babcock-Leighton-type flux-transport solar dynamo model. By performing several “observing system simulation experiments,” we reconstruct time variation in meridional flow speed and analyze sensitivity and robustness of reconstruction. Using 192 ensemble members including 10 observations, each with 4% error, we find that flow speed is reconstructed best if observations of near-surface poloidal fields from low latitudes and tachocline toroidal fields from midlatitudes are assimilated. If observations include a mixture of poloidal and toroidal fields from different latitude locations, reconstruction is reasonably good for ≤slant 40 % error in low-latitude data, even if observational error in polar region data becomes 200%, but deteriorates when observational error increases in low- and midlatitude data. Solar polar region observations are known to contain larger errors than those in low latitudes; our forward operator (a flux-transport dynamo model here) can sustain larger errors in polar region data, but is more sensitive to errors in low-latitude data. An optimal reconstruction is obtained if an assimilation interval of 15 days is used; 10- and 20-day assimilation intervals also give reasonably good results. Assimilation intervals \\lt 5 days do not produce faithful reconstructions of flow speed, because the system requires a minimum time to develop dynamics to respond to flow variations. Reconstruction also deteriorates if an assimilation interval \\gt 45 days is used, because the system’s inherent memory interferes with its short-term dynamics during a substantially long run without updating.
Copson, Sean; Calvert, Katrina; Raman, Puvaneswary; Nathan, Elizabeth; Epee, Mathias
2017-06-01
Cord prolapse is an uncommon obstetric emergency, with potentially fatal consequences for the baby if prompt action is not taken. Simulation training provides a means by which uncommon emergencies can be practised, with the aim of improving teamwork and clinical outcomes. This study aimed to determine if the introduction of a simulation-based training course was associated with an improvement in the management of cord prolapse, in particular the diagnosis to delivery interval. We also aimed to investigate if an improvement in perinatal outcomes could be demonstrated. A retrospective cohort study was performed. All cases of cord prolapse in the designated time period were identified and reviewed and a comparison of outcome measures pre- and post-training was undertaken. Thirty-one cases were identified in the pre-training period, and compared to 64 cases post-training. Documentation improved significantly post-training. There were non-significant improvements in use of spinal anaesthetic, and in the length of stay in the special care neonatal unit. There was a significant increase in the number of babies with Apgar scores less than seven at 5 min. There were no differences in the diagnosis to delivery interval, or in perinatal mortality rates. Obstetric emergency training was associated with improved teamwork, as evidenced by the improved documentation post-training in this study, but not with improved diagnosis to delivery interval. Long-term follow-up studies are required to ascertain whether training has an impact on longer-term paediatric outcomes, such as cerebral palsy rates. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
Rajagopal, Praveen; Chitre, Vidya; Aras, Meena A
2012-01-01
Traditionally, inlay casting waxes have been used to fabricate patterns for castings. Newer resin pattern materials offer greater rigidity and strength, allowing easier laboratory and intraoral adjustment without the fear of pattern damage. They also claim to possess a greater dimensional stability when compared to inlay wax. This study attempted to determine and compare the marginal accuracy of patterns fabricated from an inlay casting wax, an autopolymerized pattern resin and a light polymerized pattern resin on storage off the die for varying time intervals. Ten patterns each were fabricated from an inlay casting wax (GC Corp., Tokyo, Japan), an autopolymerized resin pattern material (Pattern resin, GC Corp, Tokyo, Japan) and a light-cured resin pattern material (Palavit GLC, Hereaus Kulzer GmbH, Germany). The completed patterns were stored off the die at room temperature. Marginal gaps were evaluated by reseating the patterns on their respective dies and observing it under a stereomicroscope at 1, 12, and 24 h intervals after pattern fabrication. The results revealed that the inlay wax showed a significantly greater marginal discrepancy at the 12 and 24 h intervals. The autopolymerized resin showed an initial (at 1 h) marginal discrepancy slightly greater than inlay wax, but showed a significantly less marginal gap (as compared to inlay wax) at the other two time intervals. The light-cured resin proved to be significantly more dimensionally stable, and showed minimal change during the storage period. The resin pattern materials studied, undergo a significantly less dimensional change than the inlay waxes on prolonged storage. They would possibly be a better alternative to inlay wax in situations requiring high precision or when delayed investment (more than 1 h) of patterns can be expected.
VizieR Online Data Catalog: Fermi/GBM GRB time-resolved spectral catalog (Yu+, 2016)
NASA Astrophysics Data System (ADS)
Yu, H.-F.; Preece, R. D.; Greiner, J.; Bhat, P. N.; Bissaldi, E.; Briggs, M. S.; Cleveland, W. H.; Connaughton, V.; Goldstein, A.; von Kienlin; A.; Kouveliotou, C.; Mailyan, B.; Meegan, C. A.; Paciesas, W. S.; Rau, A.; Roberts, O. J.; Veres, P.; Wilson-Hodge, C.; Zhang, B.-B.; van Eerten, H. J.
2016-01-01
Time-resolved spectral analysis results of BEST models: for each spectrum GRB name using the Fermi GBM trigger designation, spectrum number within individual burst, start time Tstart and end time Tstop for the time bin, BEST model, best-fit parameters of the BEST model, value of CSTAT per degrees of freedom, 10keV-1MeV photon and energy flux are given. Ep evolutionary trends: for each burst GRB name, number of spectra with Ep, Spearman's Rank Correlation Coefficients between Ep_ and photon flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficients between Ep and energy flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficient between Ep and time and 90%, 95%, and 99% confidence intervals, trends as determined by computer for 90%, 95%, and 99% confidence intervals, trends as determined by human eyes are given. (2 data files).
Altink, Marieke E.; Oosterlaan, Jaap; Beem, Leo; Buschgens, Cathelijne J. M.; Buitelaar, Jan; Sergeant, Joseph A.
2007-01-01
Attention-Deficit/Hyperactivity Disorder (ADHD) shares a genetic basis with motor coordination problems and probably motor timing problems. In line with this, comparable problems in motor timing should be observed in first degree relatives and might, therefore, form a suitable endophenotypic candidate. This hypothesis was investigated in 238 ADHD-families (545 children) and 147 control-families (271 children). A motor timing task was administered, in which children had to produce a 1,000 ms interval. In addition to this task, two basic motor tasks were administered to examine speed and variability of motor output, when no timing component was required. Results indicated that variability in motor timing is a useful endophenotypic candidate: It was clearly associated with ADHD, it was also present in non-affected siblings, and it correlated within families. Accuracy (under- versus over-production) in motor timing appeared less useful: Even though accuracy was associated with ADHD (probands and affected siblings had a tendency to under-produce the 1,000 ms interval compared to controls), non-affected siblings did not differ from controls and sibling correlations were only marginally significant. Slow and variable motor output without timing component also appears present in ADHD, but not in non-affected siblings, suggesting these deficits not to be related to a familial vulnerability for ADHD. Deficits in motor timing could not be explained by deficits already present in basic motor output without a timing component. This suggests abnormalities in motor timing were predominantly related to deficient motor timing processes and not to general deficient motor functioning. The finding that deficits in motor timing run in ADHD-families suggests this to be a fruitful domain for further exploration in relation to the genetic underpinnings of ADHD. PMID:18071893
Healthy Lifestyle Fitness Interval training can help you get the most out of your workout. By Mayo Clinic Staff Are you ready to shake ... spending more time at the gym? Consider aerobic interval training. Once the domain of elite athletes, interval training ...
Measuring Land Change in Coastal Zone around a Rapidly Urbanized Bay.
Huang, Faming; Huang, Boqiang; Huang, Jinliang; Li, Shenghui
2018-05-23
Urban development is a major cause for eco-degradation in many coastal regions. Understanding urbanization dynamics and underlying driving factors is crucial for urban planning and management. Land-use dynamic degree indices and intensity analysis were used to measure land changes occurred in 1990, 2002, 2009, and 2017 in the coastal zone around Quanzhou bay, which is a rapidly urbanized bay in Southeast China. The comprehensive land-use dynamic degree and interval level intensity analysis both revealed that land change was accelerating across the three time intervals in a three-kilometer-wide zone along the coastal line (zone A), while land change was fastest during the second time interval 2002⁻2009 in a separate terrestrial area within coastal zone (zone B). Driven by urbanization, built-up gains and cropland losses were active for all time intervals in both zones. Mudflat losses were active except in the first time interval in zone A due to the intensive sea reclamation. The gain of mangrove was active while the loss of mangrove is dormant for all three intervals in zone A. Transition level analysis further revealed the similarities and differences in processes within patterns of land changes for both zones. The transition from cropland to built-up was systematically targeted and stationary while the transition from woodland to built-up was systematically avoiding transition in both zones. Built-up tended to target aquaculture for the second and third time intervals in zone A but avoid Aquaculture for all intervals in zone B. Land change in zone A was more significant than that in zone B during the second and third time intervals at three-level intensity. The application of intensity analysis can enhance our understanding of the patterns and processes in land changes and suitable land development plans in the Quanzhou bay area. This type of investigation is useful to provide information for developing sound land use policy to achieve urban sustainability in similar coastal areas.
Timing and documentation of key events in neonatal resuscitation.
Heathcote, Adam Charles; Jones, Jacqueline; Clarke, Paul
2018-04-30
Only a minority of babies require extended resuscitation at birth. Resuscitations concerning babies who die or who survive with adverse outcomes are increasingly subject to medicolegal scrutiny. Our aim was to describe real-life timings of key resuscitation events observed in a historical series of newborns who required full resuscitation at birth. Twenty-seven babies born in our centre over a 10-year period had an Apgar score of 0 at 1 min and required full resuscitation. The median (95% confidence interval) postnatal age at achieving key events were commencing cardiac compressions, 2.0 (1.5-4.0) min; endotracheal intubation, 3.8 (2.0-6.0) min; umbilical venous catheterisation 9.0 (7.5-12.0) min; and administration of first adrenaline dose 10.0 (8.0-14.0) min. The wide range of timings presented from real-life cases may prove useful to clinicians involved in medical negligence claims and provide a baseline for quality improvements in resuscitation training. What is Known: • Only a minority of babies require extended resuscitation at birth; these cases are often subject to medicolegal interrogation • Timings of key resuscitation events are poorly described and documentation of resuscitation events is often lacking yet is open to medicolegal scrutiny What is New: • We present a wide range of real-life timings of key resuscitation events during the era of routine newborn life support training • These timings may prove useful to clinicians involved in medical negligence claims and provide a baseline for quality improvements in resuscitation training.
Tremblay, Marc; Vézina, Hélène
2000-01-01
Summary Intergenerational time intervals are frequently used in human population-genetics studies concerned with the ages and origins of mutations. In most cases, mean intervals of 20 or 25 years are used, regardless of the demographic characteristics of the population under study. Although these characteristics may vary from prehistoric to historical times, we suggest that this value is probably too low, and that the ages of some mutations may have been underestimated. Analyses were performed by using the BALSAC Population Register (Quebec, Canada), from which several intergenerational comparisons can be made. Family reconstitutions were used to measure interval lengths and variations in descending lineages. Various parameters were considered, such as spouse age at marriage, parental age, and reproduction levels. Mother-child and father-child intervals were compared. Intergenerational male and female intervals were also analyzed in 100 extended ascending genealogies. Results showed that a mean value of 30 years is a better estimate of intergenerational intervals than 20 or 25 years. As marked differences between male and female interval length were observed, specific values are proposed for mtDNA, autosomal, X-chromosomal, and Y-chromosomal loci. The applicability of these results for age estimates of mutations is discussed. PMID:10677323
The effects of morphine on fixed-interval patterning and temporal discrimination.
Odum, A L; Schaal, D W
2000-01-01
Changes produced by drugs in response patterns under fixed-interval schedules of reinforcement have been interpreted to result from changes in temporal discrimination. To examine this possibility, this experiment determined the effects of morphine on the response patterning of 4 pigeons during a fixed-interval 1-min schedule of food delivery with interpolated temporal discrimination trials. Twenty of the 50 total intervals were interrupted by choice trials. Pecks to one key color produced food if the interval was interrupted after a short time (after 2 or 4.64 s). Pecks to another key color produced food if the interval was interrupted after a long time (after 24.99 or 58 s). Morphine (1.0 to 10.0 mg/kg) decreased the index of curvature (a measure of response patterning) during fixed intervals and accuracy during temporal discrimination trials. Accuracy was equally disrupted following short and long sample durations. Although morphine disrupted temporal discrimination in the context of a fixed-interval schedule, these effects are inconsistent with interpretations of the disruption of response patterning as a selective overestimation of elapsed time. The effects of morphine may be related to the effects of more conventional external stimuli on response patterning. PMID:11029024
Context-Dependent Duration Signals in the Primate Prefrontal Cortex
Genovesio, Aldo; Seitz, Lucia K.; Tsujimoto, Satoshi; Wise, Steven P.
2016-01-01
The activity of some prefrontal (PF) cortex neurons distinguishes short from long time intervals. Here, we examined whether this property reflected a general timing mechanism or one dependent on behavioral context. In one task, monkeys discriminated the relative duration of 2 stimuli; in the other, they discriminated the relative distance of 2 stimuli from a fixed reference point. Both tasks had a pre-cue period (interval 1) and a delay period (interval 2) with no discriminant stimulus. Interval 1 elapsed before the presentation of the first discriminant stimulus, and interval 2 began after that stimulus. Both intervals had durations of either 400 or 800 ms. Most PF neurons distinguished short from long durations in one task or interval, but not in the others. When neurons did signal something about duration for both intervals, they did so in an uncorrelated or weakly correlated manner. These results demonstrate a high degree of context dependency in PF time processing. The PF, therefore, does not appear to signal durations abstractedly, as would be expected of a general temporal encoder, but instead does so in a highly context-dependent manner, both within and between tasks. PMID:26209845
NASA Technical Reports Server (NTRS)
Spodick, D. H.; Quarry, V. M.; Khan, A. H.
1974-01-01
Systolic and diastolic time intervals in 14 cardiac patients with pulsus alternans revealed significant alternation of preinjection period (PEP), isovolumic contraction time (IVCT), left ventricular ejection time (LVET), ejection time index (ETI), PEP/LVET, and carotid dD/dt with better functional values in the strong beats. Cycle length, duration of electromechanical systole (EMS) and total diastole, i.e., isovolumic relaxation period (IRP) and diastolic filling period (DFP) occurred in 7 out of 8 patients. These diastolic intervals alternated reciprocally such that the IRP of the strong beats encroached upon the DFP of the next (weak) beats.
Evaluation of behavioral outcomes in children 1 year after epilepsy surgery.
Law, Nicole; Kerr, Elizabeth; Smith, Mary Lou
2015-10-01
Children with epilepsy have elevated rates of behavior problems. Research findings on the impact of epilepsy surgery on children's behavior have been mixed, with some studies showing improvements in behavior 3 to 18 months after surgery and other studies finding no change within this time interval. We examined behavior in a large surgical sample and in a nonsurgical comparison group. We also examined for potential effects of epilepsy-related and cognitive/linguistic variables. Behavior was assessed by parent report in 147 children who underwent epilepsy surgery and 40 children who did not, using the Child Behavior Checklist (CBCL). For the surgical group, the CBCL was completed prior to surgery (baseline) and approximately 1 year after surgery (follow-up); ratings of the nonsurgical group were also conducted twice, at comparable intervals. At baseline, the groups did not differ on age, sex, age at seizure onset, antiepileptic drugs (AEDs), or intelligence quotient (IQ). Baseline Social and Attention Problems were higher in the nonsurgical group. At follow-up, 65% of the surgical group and 20% of the nonsurgical group were seizure-free. Behavioral change was not related to surgical status or seizure outcome. Children with temporal lobe seizure focus had more Externalizing Behaviors compared to those with frontal or multilobar foci. Attention was poorer in children who underwent frontal lobe excisions relative to temporal or multilobar excisions. Baseline IQ did not predict behavioral change. Our results suggest that surgery and seizure outcome do not affect behavior in the first year following surgery; it may be the abnormal neural substrate and not seizure control that influences behavior in children with epilepsy. If changes are to occur due to seizure freedom, they may require a longer time to emerge. Some behaviors may be resistant to change in children with epilepsy or may require even longer intervals for improvement. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.
Carter, Michael J; Ste-Marie, Diane M
2017-03-01
The learning advantages of self-controlled knowledge-of-results (KR) schedules compared to yoked schedules have been linked to the optimization of the informational value of the KR received for the enhancement of one's error-detection capabilities. This suggests that information-processing activities that occur after motor execution, but prior to receiving KR (i.e., the KR-delay interval) may underlie self-controlled KR learning advantages. The present experiment investigated whether self-controlled KR learning benefits would be eliminated if an interpolated activity was performed during the KR-delay interval. Participants practiced a waveform matching task that required two rapid elbow extension-flexion reversals in one of four groups using a factorial combination of choice (self-controlled, yoked) and KR-delay interval (empty, interpolated). The waveform had specific spatial and temporal constraints, and an overall movement time goal. The results indicated that the self-controlled + empty group had superior retention and transfer scores compared to all other groups. Moreover, the self-controlled + interpolated and yoked + interpolated groups did not differ significantly in retention and transfer; thus, the interpolated activity eliminated the typically found learning benefits of self-controlled KR. No significant differences were found between the two yoked groups. We suggest the interpolated activity interfered with information-processing activities specific to self-controlled KR conditions that occur during the KR-delay interval and that these activities are vital for reaping the associated learning benefits. These findings add to the growing evidence that challenge the motivational account of self-controlled KR learning advantages and instead highlights informational factors associated with the KR-delay interval as an important variable for motor learning under self-controlled KR schedules.
NASA Astrophysics Data System (ADS)
Hakim Halim, Abdul; Ernawati; Hidayat, Nita P. A.
2018-03-01
This paper deals with a model of batch scheduling for a single batch processor on which a number of parts of a single items are to be processed. The process needs two kinds of setups, i. e., main setups required before processing any batches, and additional setups required repeatedly after the batch processor completes a certain number of batches. The parts to be processed arrive at the shop floor at the times coinciding with their respective starting times of processing, and the completed parts are to be delivered at multiple due dates. The objective adopted for the model is that of minimizing total inventory holding cost consisting of holding cost per unit time for a part in completed batches, and that in in-process batches. The formulation of total inventory holding cost is derived from the so-called actual flow time defined as the interval between arrival times of parts at the production line and delivery times of the completed parts. The actual flow time satisfies not only minimum inventory but also arrival and delivery just in times. An algorithm to solve the model is proposed and a numerical example is shown.
Learned Interval Time Facilitates Associate Memory Retrieval
ERIC Educational Resources Information Center
van de Ven, Vincent; Kochs, Sarah; Smulders, Fren; De Weerd, Peter
2017-01-01
The extent to which time is represented in memory remains underinvestigated. We designed a time paired associate task (TPAT) in which participants implicitly learned cue-time-target associations between cue-target pairs and specific cue-target intervals. During subsequent memory testing, participants showed increased accuracy of identifying…
NASA Technical Reports Server (NTRS)
Wardrip, S. C. (Editor)
1979-01-01
Thirty eight papers are presented addressing various aspects of precise time and time interval applications. Areas discussed include: past accomplishments; state of the art systems; new and useful applications, procedures, and techniques; and fruitful directions for research efforts.
McGregor, Tracy L.; Jones, Deborah P.; Wang, Li; Danciu, Ioana; Bridges, Brian C.; Fleming, Geoffrey M.; Shirey-Rice, Jana; Chen, Lixin; Byrne, Daniel W.; Van Driest, Sara L.
2015-01-01
Background Acute kidney injury (AKI) has been characterized in young high-risk inpatients, in whom AKI is frequent and associated with increased mortality, morbidity, and length of stay. The incidence of AKI among patients not requiring intensive care is unknown. Study Design Retrospective cohort study Setting & Participants 13,914 noncritical admissions during 2011–2012 at our tertiary referral pediatric hospital were evaluated. Patients <28 days or >21 years of age, or with chronic kidney disease (CKD), were excluded. Admissions with ≥2 serum creatinine measurements were evaluated. Factors Demographic features, laboratory measurements, medication exposures, and length of stay. Outcome AKI defined by increased serum creatinine in accordance with KDIGO (Kidney Disease: Improving Global Outcomes) criteria. Based on time of admission, time interval requirements were met in 97% of cases, but KDIGO time window criteria were not strictly enforced to allow implementation using clinically-obtained data. Results Two or more creatinine measurements (one baseline before or during admission, and a second during admission) in 2,374 of 13,914 (17%) patients allowed for AKI evaluation. A serum creatinine difference of ≥0.3 mg/dL or ≥1.5 times baseline was seen in 722 of 2,374 (30%) patients. A minimum of 5% of all noncritical inpatients without CKD in pediatric wards have an episode of AKI during routine hospital admission. Limitations Urine output, glomerular filtration rate, and time interval criteria for AKI were not applied secondary to study design and available data. The evaluated cohort was restricted to patients with ≥2 clinically obtained serum creatinine measurements, and baseline creatinine may have been measured after the AKI episode. Conclusions AKI occurs in at least 5% of all non-critically ill hospitalized children, adolescents, and young adults without known CKD. Physicians should increase their awareness of AKI and improve surveillance strategies with serum creatinine measurements in this population so that exacerbating factors such as nephrotoxic medication exposures may be modified as indicated. PMID:26319754
Assessment of toxicity and coagulopathy of brodifacoum in Japanese quail and testing in wild owls.
Webster, Kirstin H; Harr, Kendal E; Bennett, Darin C; Williams, Tony D; Cheng, Kimberly M; Maisonneuve, France; Elliott, John E
2015-07-01
Based on detection of hepatic residues, scavenging and predatory non-target raptors are widely exposed to second generation anticoagulant rodenticides (SGARs). A small proportion, generally <10%, of tested birds are diagnosed as acutely poisoned. Little is known, however, of sub-lethal effects of SGARs, such as interaction of clotting capacity with traumatic injury. Assessment of coagulation function of birds submitted live to wildlife rehabilitators or veterinarians may provide a means of establishing the proportion of animals suffering sub-lethal coagulopathies, as well as identifying individuals requiring treatment. As a first step in exploring the potential of this approach, we dosed Japanese quail (Coturnix japonica) with the SGAR, brodifacoum, at 0, 0.8, 1.4, 1.9, and 2.5 mg/kg and sampled birds at 1, 3, 5 and 7 days post-dosing. Prothrombin time (PT), which measures the extrinsic coagulation pathway, was significantly prolonged in 98% of brodifacoum-exposed quail in a dose- and time-dependent manner. 50-fold prolongation of PT occurred at higher brodifacoum dosages and correlated to hemorrhage found at necropsy. Activated clotting time (ACT), a measure of the intrinsic pathway also increased with dose and time. Hemoglobin (Hb) and hematocrit (Hct) decreased dose- and time-dependently at doses ≥1.4 mg/kg with no significant change at 0.8 mg/kg. Reference intervals for PT (10.0-16.2 s), ACT (30-180 s), Hb (9.6-18.4 g/dl), and Hct (34-55%) were established in Japanese quail. Species-specific reference intervals are required as barn owl PT (17-29 s) and quail PT were different. The proportion of brodifacoum-exposed quail with hemorrhage was not correlated with liver residues, but was correlated with PT, suggesting that this assay is a useful indicator of avian anticoagulant rodenticide exposure. PTs measured in free-living barn owls sampled between April 2009 and August 2010 in the lower Fraser Valley of BC do not suggest significant exposure to SGARs.
The Behavioral Economics of Choice and Interval Timing
ERIC Educational Resources Information Center
Jozefowiez, J.; Staddon, J. E. R.; Cerutti, D. T.
2009-01-01
The authors propose a simple behavioral economic model (BEM) describing how reinforcement and interval timing interact. The model assumes a Weber-law-compliant logarithmic representation of time. Associated with each represented time value are the payoffs that have been obtained for each possible response. At a given real time, the response with…
Generating variable and random schedules of reinforcement using Microsoft Excel macros.
Bancroft, Stacie L; Bourret, Jason C
2008-01-01
Variable reinforcement schedules are used to arrange the availability of reinforcement following varying response ratios or intervals of time. Random reinforcement schedules are subtypes of variable reinforcement schedules that can be used to arrange the availability of reinforcement at a constant probability across number of responses or time. Generating schedule values for variable and random reinforcement schedules can be difficult. The present article describes the steps necessary to write macros in Microsoft Excel that will generate variable-ratio, variable-interval, variable-time, random-ratio, random-interval, and random-time reinforcement schedule values.
Can ivermectin mass treatments eliminate onchocerciasis in Africa?
Winnen, M.; Plaisier, A. P.; Alley, E. S.; Nagelkerke, N. J. D.; van Oortmarssen, G.; Boatin, B. A.; Habbema, J. D. F.
2002-01-01
OBJECTIVE: To elucidate the conditions in which mass treatment with ivermectin reduces the transmission of Onchocerca volvulus sufficiently to eliminate infection from an African community. METHODS: ONCHOSIM, a microsimulation model for onchocerciasis transmission, was used to explore the implications of different treatment intervals, coverage levels and precontrol endemicities for the likelihood of elimination. FINDINGS: Simulations suggested that control strategies based exclusively on ivermectin mass treatments could eliminate onchocerciasis. The duration of treatment required to eliminate infection depended heavily on the treatment programme and precontrol endemicity. In areas with medium to high levels of infection, annual mass treatments with 65% coverage for at least 25 years were necessary. Model predictions suggested that durations exceeding 35 years would be required if there were much heterogeneity in exposure to vector bites and, consequently, wide individual variation in microfilaria counts. If the treatment interval were reduced from 12 to 6 months the time for completion of the programme could be more than halved and elimination could be accomplished in areas of hyperendemicity, provided that the effects of each treatment would be the same as with annual treatments. However, it was doubtful whether high coverage levels could be sustained long enough to achieve worldwide eradication. CONCLUSION: Elimination of onchocerciasis from most endemic foci in Africa appears to be possible. However, the requirements in terms of duration, coverage, and frequency of treatment may be prohibitive in highly endemic areas. PMID:12077614
Digital computing cardiotachometer
NASA Technical Reports Server (NTRS)
Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)
1973-01-01
A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.
NASA Technical Reports Server (NTRS)
Webster, W. J., Jr.
1986-01-01
The shuttle-deployed and recovered Spartan shows promise as an inexpensive and simple support module for potential field measurements. The results of a preliminary engineering study on the applications of the Spartan carrier to magnetic measurements shows: (1) Extension of the mission duration to as long as 7 days is feasible but requires more reconfiguration of the internal systems; (2) On-board recording of Global Positioning System signals will provide position determination with an accuracy consistent with the most severe requirements; and (3) Making Spartan a magnetically clean spacecraft is straight forward but requires labor-intensive modifications to both the data and power systems. As a magnetic survey tool, Spartan would allow surveys at regularly spaced intervals and could make quick-reaction surveys at times of instability in the secular variation.
Post-KR Delay Intervals and Mental Practice: A Test of Adams' Closed Loop Theory
ERIC Educational Resources Information Center
Bole, Ronald
1976-01-01
The present study suggests that post-KR delay interval time or activity in the interval has little to do with learning on a self-paced positioning task, not ruling out that on ballistic tasks or more complex nonballistic tasks that a learner could make use of additional time or strategy. (MB)