Sample records for time points ranging

  1. Normalization methods in time series of platelet function assays

    PubMed Central

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  2. Use of precision time and time interval (PTTI)

    NASA Technical Reports Server (NTRS)

    Taylor, J. D.

    1974-01-01

    A review of range time synchronization methods are discussed as an important aspect of range operations. The overall capabilities of various missile ranges to determine precise time of day by synchronizing to available references and applying this time point to instrumentation for time interval measurements are described.

  3. Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Sigeaki; Toyooka, Satoru

    1995-10-01

    The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.

  4. A Well-Clear Volume Based on Time to Entry Point

    NASA Technical Reports Server (NTRS)

    Narkawicz, Anthony J.; Munoz, Cesar A.; Upchurch, Jason M.; Chamberlain, James P.; Consiglio, Maria C.

    2014-01-01

    A well-clear volume is a key component of NASA's Separation Assurance concept for the integration of UAS in the NAS. This paper proposes a mathematical definition of the well-clear volume that uses, in addition to distance thresholds, a time threshold based on time to entry point (TEP). The mathematical model that results from this definition is more conservative than other candidate definitions of the wellclear volume that are based on range over closure rate and time to closest point of approach.

  5. ICESAT Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis

    NASA Technical Reports Server (NTRS)

    Luthcke, Scott B.; Rowlands, D. D.; Carabajal, C. C.; Harding, D. H.; Bufton, J. L.; Williams, T. A.

    2003-01-01

    On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfully placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which has a primary measurement of short-pulse laser- ranging to the Earth s surface at 1064nm wavelength at a rate of 40 pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS s surface returns, the spots from which the laser energy reflects on the Earth s surface, is a critical issue in the scientific application of these data. Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. ICESat laser altimeter data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers in order to calibrate pointing, ranging and timing. The calibration methodology and current calibration results are discussed along with future efforts.

  6. Phased-array ultrasonic surface contour mapping system and method for solids hoppers and the like

    DOEpatents

    Fasching, George E.; Smith, Jr., Nelson S.

    1994-01-01

    A real time ultrasonic surface contour mapping system is provided including a digitally controlled phased-array of transmitter/receiver (T/R) elements located in a fixed position above the surface to be mapped. The surface is divided into a predetermined number of pixels which are separately scanned by an arrangement of T/R elements by applying phase delayed signals thereto that produce ultrasonic tone bursts from each T/R that arrive at a point X in phase and at the same time relative to the leading edge of the tone burst pulse so that the acoustic energies from each T/R combine in a reinforcing manner at point X. The signals produced by the reception of the echo signals reflected from point X back to the T/Rs are also delayed appropriately so that they add in phase at the input of a signal combiner. This combined signal is then processed to determine the range to the point X using density-corrected sound velocity values. An autofocusing signal is developed from the computed average range for a complete scan of the surface pixels. A surface contour map is generated in real time form the range signals on a video monitor.

  7. Spacecraft Station-Keeping Trajectory and Mission Design Tools

    NASA Technical Reports Server (NTRS)

    Chung, Min-Kun J.

    2009-01-01

    Two tools were developed for designing station-keeping trajectories and estimating delta-v requirements for designing missions to a small body such as a comet or asteroid. This innovation uses NPOPT, a non-sparse, general-purpose sequential quadratic programming (SQP) optimizer and the Two-Level Differential Corrector (T-LDC) in LTool (Libration point mission design Tool) to design three kinds of station-keeping scripts: vertical hovering, horizontal hovering, and orbiting. The T-LDC is used to differentially correct several trajectory legs that join hovering points. In a vertical hovering, the maximum and minimum range points must be connected smoothly while maintaining the spacecrafts range from a small body, all within the law of gravity and the solar radiation pressure. The same is true for a horizontal hover. A PatchPoint is an LTool class that denotes a space-time event with some extra information for differential correction, including a set of constraints to be satisfied by T-LDC. Given a set of PatchPoints, each with its own constraint, the T-LDC differentially corrects the entire trajectory by connecting each trajectory leg joined by PatchPoints while satisfying all specified constraints at the same time. Vertical and horizontal hover both are needed to minimize delta-v spent for station keeping. A Python I/F to NPOPT has been written to be used from an LTool script. In vertical hovering, the spacecraft stays along the line joining the Sun and a small body. An instantaneous delta-v toward the anti- Sun direction is applied at the closest approach to the small body for station keeping. For example, the spacecraft hovers between the minimum range (2 km) point and the maximum range (2.5 km) point from the asteroid 1989ML. Horizontal hovering buys more time for a spacecraft to recover if, for any reason, a planned thrust fails, by returning almost to the initial position after some time later via a near elliptical orbit around the small body. The mapping or staging orbit may be similarly generated using T-LDC with a set of constraints. Some delta-v tables are generated for several different asteroid masses.

  8. Assessment of Image Quality of Repeated Limited Transthoracic Echocardiography After Cardiac Surgery.

    PubMed

    Canty, David J; Heiberg, Johan; Tan, Jen A; Yang, Yang; Royse, Alistair G; Royse, Colin F; Mobeirek, Abdulelah; Shaer, Fayez El; Albacker, Turki; Nazer, Rakan I; Fouda, Muhammed; Bakir, Bakir M; Alsaddique, Ahmed A

    2017-06-01

    The use of limited transthoracic echocardiography (TTE) has been restricted in patients after cardiac surgery due to reported poor image quality. The authors hypothesized that the hemodynamic state could be evaluated in a high proportion of patients at repeated intervals after cardiac surgery. Prospective observational study. Tertiary university hospital. The study comprised 51 patients aged 18 years or older presenting for cardiac surgery. Patients underwent TTE before surgery and at 3 time points after cardiac surgery. Images were assessed offline using an image quality scoring system by 2 expert observers. Hemodynamic state was assessed using the iHeartScan protocol, and the primary endpoint was the proportion of limited TTE studies in which the hemodynamic state was interpretable at each of the 3 postoperative time points. Hemodynamic state interpretability varied over time and was highest before surgery (90%) and lowest on the first postoperative day (49%) (p<0.01). This variation in interpretability over time was reflected in all 3 transthoracic windows, ranging from 43% to 80% before surgery and from 2% to 35% on the first postoperative day (p<0.01). Image quality scores were highest with the apical window, ranging from 53% to 77% across time points, and lowest with the subcostal window, ranging from 4% to 70% across time points (p< 0.01). Hemodynamic state can be determined with TTE in a high proportion of cardiac surgery patients after extubation and removal of surgical drains. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, R; Zhu, X; Li, S

    Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginalmore » mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.« less

  10. ICESat Laser Altimeter Pointing, Ranging and Timing Calibration from Integrated Residual Analysis: A Summary of Early Mission Results

    NASA Technical Reports Server (NTRS)

    Lutchke, Scott B.; Rowlands, David D.; Harding, David J.; Bufton, Jack L.; Carabajal, Claudia C.; Williams, Teresa A.

    2003-01-01

    On January 12, 2003 the Ice, Cloud and land Elevation Satellite (ICESat) was successfUlly placed into orbit. The ICESat mission carries the Geoscience Laser Altimeter System (GLAS), which consists of three near-infrared lasers that operate at 40 short pulses per second. The instrument has collected precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLAS's surface returns, the spots from which the laser energy reflects on the Earth's surface, is a critical issue in the scientific application of these data Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. Early mission ICESat data have been simultaneously processed as direct altimetry from ocean sweeps along with dynamic crossovers resulting in a preliminary calibration of laser pointing, ranging and timing. The calibration methodology and early mission analysis results are summarized in this paper along with future calibration activities

  11. Empirical mode decomposition and long-range correlation analysis of sunspot time series

    NASA Astrophysics Data System (ADS)

    Zhou, Yu; Leung, Yee

    2010-12-01

    Sunspots, which are the best known and most variable features of the solar surface, affect our planet in many ways. The number of sunspots during a period of time is highly variable and arouses strong research interest. When multifractal detrended fluctuation analysis (MF-DFA) is employed to study the fractal properties and long-range correlation of the sunspot series, some spurious crossover points might appear because of the periodic and quasi-periodic trends in the series. However many cycles of solar activities can be reflected by the sunspot time series. The 11-year cycle is perhaps the most famous cycle of the sunspot activity. These cycles pose problems for the investigation of the scaling behavior of sunspot time series. Using different methods to handle the 11-year cycle generally creates totally different results. Using MF-DFA, Movahed and co-workers employed Fourier truncation to deal with the 11-year cycle and found that the series is long-range anti-correlated with a Hurst exponent, H, of about 0.12. However, Hu and co-workers proposed an adaptive detrending method for the MF-DFA and discovered long-range correlation characterized by H≈0.74. In an attempt to get to the bottom of the problem in the present paper, empirical mode decomposition (EMD), a data-driven adaptive method, is applied to first extract the components with different dominant frequencies. MF-DFA is then employed to study the long-range correlation of the sunspot time series under the influence of these components. On removing the effects of these periods, the natural long-range correlation of the sunspot time series can be revealed. With the removal of the 11-year cycle, a crossover point located at around 60 months is discovered to be a reasonable point separating two different time scale ranges, H≈0.72 and H≈1.49. And on removing all cycles longer than 11 years, we have H≈0.69 and H≈0.28. The three cycle-removing methods—Fourier truncation, adaptive detrending and the proposed EMD-based method—are further compared, and possible reasons for the different results are given. Two numerical experiments are designed for quantitatively evaluating the performances of these three methods in removing periodic trends with inexact/exact cycles and in detecting the possible crossover points.

  12. A Comparison of Methods for Estimating Relationships in the Change between Two Time Points for Latent Variables

    ERIC Educational Resources Information Center

    Finch, W. Holmes; Shim, Sungok Serena

    2018-01-01

    Collection and analysis of longitudinal data is an important tool in understanding growth and development over time in a whole range of human endeavors. Ideally, researchers working in the longitudinal framework are able to collect data at more than two points in time, as this will provide them with the potential for a deeper understanding of the…

  13. A high-resolution full-field range imaging system

    NASA Astrophysics Data System (ADS)

    Carnegie, D. A.; Cree, M. J.; Dorrington, A. A.

    2005-08-01

    There exist a number of applications where the range to all objects in a field of view needs to be obtained. Specific examples include obstacle avoidance for autonomous mobile robots, process automation in assembly factories, surface profiling for shape analysis, and surveying. Ranging systems can be typically characterized as being either laser scanning systems where a laser point is sequentially scanned over a scene or a full-field acquisition where the range to every point in the image is simultaneously obtained. The former offers advantages in terms of range resolution, while the latter tend to be faster and involve no moving parts. We present a system for determining the range to any object within a camera's field of view, at the speed of a full-field system and the range resolution of some point laser scans. Initial results obtained have a centimeter range resolution for a 10 second acquisition time. Modifications to the existing system are discussed that should provide faster results with submillimeter resolution.

  14. ASRDI oxygen technology survey. Volume 4: Low temperature measurement

    NASA Technical Reports Server (NTRS)

    Sparks, L. L.

    1974-01-01

    Information is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations.

  15. An Archeological Overview and Management Plan for the U.S. Army Natick Research and Development Laboratories.

    DTIC Science & Technology

    1984-06-01

    bifurcate-base points, Kirk points, Plano points). During this time period temperate species were expanding their ranges northward and eastward. Early...textured. A second type of ceramics is smooth-bodled or incised , fiber-or-steatite tempered, manufactured by modeling, has flat bottoms and shows

  16. Investigating the Accuracy of Point Clouds Generated for Rock Surfaces

    NASA Astrophysics Data System (ADS)

    Seker, D. Z.; Incekara, A. H.

    2016-12-01

    Point clouds which are produced by means of different techniques are widely used to model the rocks and obtain the properties of rock surfaces like roughness, volume and area. These point clouds can be generated by applying laser scanning and close range photogrammetry techniques. Laser scanning is the most common method to produce point cloud. In this method, laser scanner device produces 3D point cloud at regular intervals. In close range photogrammetry, point cloud can be produced with the help of photographs taken in appropriate conditions depending on developing hardware and software technology. Many photogrammetric software which is open source or not currently provide the generation of point cloud support. Both methods are close to each other in terms of accuracy. Sufficient accuracy in the mm and cm range can be obtained with the help of a qualified digital camera and laser scanner. In both methods, field work is completed in less time than conventional techniques. In close range photogrammetry, any part of rock surfaces can be completely represented owing to overlapping oblique photographs. In contrast to the proximity of the data, these two methods are quite different in terms of cost. In this study, whether or not point cloud produced by photographs can be used instead of point cloud produced by laser scanner device is investigated. In accordance with this purpose, rock surfaces which have complex and irregular shape located in İstanbul Technical University Ayazaga Campus were selected as study object. Selected object is mixture of different rock types and consists of both partly weathered and fresh parts. Study was performed on a part of 30m x 10m rock surface. 2D and 3D analysis were performed for several regions selected from the point clouds of the surface models. 2D analysis is area-based and 3D analysis is volume-based. Analysis conclusions showed that point clouds in both are similar and can be used as alternative to each other. This proved that point cloud produced using photographs which are both economical and enables to produce data in less time can be used in several studies instead of point cloud produced by laser scanner.

  17. Efficient generation of discontinuity-preserving adaptive triangulations from range images.

    PubMed

    Garcia, Miguel Angel; Sappa, Angel Domingo

    2004-10-01

    This paper presents an efficient technique for generating adaptive triangular meshes from range images. The algorithm consists of two stages. First, a user-defined number of points is adaptively sampled from the given range image. Those points are chosen by taking into account the surface shapes represented in the range image in such a way that points tend to group in areas of high curvature and to disperse in low-variation regions. This selection process is done through a noniterative, inherently parallel algorithm in order to gain efficiency. Once the image has been subsampled, the second stage applies a two and one half-dimensional Delaunay triangulation to obtain an initial triangular mesh. To favor the preservation of surface and orientation discontinuities (jump and crease edges) present in the original range image, the aforementioned triangular mesh is iteratively modified by applying an efficient edge flipping technique. Results with real range images show accurate triangular approximations of the given range images with low processing times.

  18. Time course of the acute effects of core stabilisation exercise on seated postural control.

    PubMed

    Lee, Jordan B; Brown, Stephen H M

    2017-09-20

    Core stabilisation exercises are often promoted for purposes ranging from general fitness to high-performance athletics, and the prevention and rehabilitation of back troubles. These exercises, when performed properly, may have the potential to enhance torso postural awareness and control, yet the potential for achieving immediate gains has not been completely studied. Fourteen healthy young participants performed a single bout of non-fatiguing core stabilisation exercise that consisted of repeated sets of 2 isometric exercises, the side bridge and the four-point contralateral arm-and-leg extension. Seated postural control, using an unstable balance platform on top of a force plate, was assessed before and after exercise, including multiple time points within a 20-minute follow-up period. Nine standard postural control variables were calculated at each time point, including sway displacement and velocity ranges, root mean squares and cumulative path length. Statistical analysis showed that none of the postural control variables were significantly different at any time point following completion of core stabilisation exercise. Thus, we conclude that a single bout of acute core stabilisation exercise is insufficient to immediately improve seated trunk postural control in young healthy individuals.

  19. Light beam range finder

    DOEpatents

    McEwan, Thomas E.

    1998-01-01

    A "laser tape measure" for measuring distance which includes a transmitter such as a laser diode which transmits a sequence of electromagnetic pulses in response to a transmit timing signal. A receiver samples reflections from objects within the field of the sequence of visible electromagnetic pulses with controlled timing, in response to a receive timing signal. The receiver generates a sample signal in response to the samples which indicates distance to the object causing the reflections. The timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the reflection such that the time between transmission of pulses in the sequence in sampling by the receiver sweeps over a range of delays. The transmit timing signal causes the transmitter to transmit the sequence of electromagnetic pulses at a pulse repetition rate, and the received timing signal sweeps over the range of delays in a sweep cycle such that reflections are sampled at the pulse repetition rate and with different delays in the range of delays, such that the sample signal represents received reflections in equivalent time. The receiver according to one aspect of the invention includes an avalanche photodiode and a sampling gate coupled to the photodiode which is responsive to the received timing signal. The transmitter includes a laser diode which supplies a sequence of visible electromagnetic pulses. A bright spot projected on to the target clearly indicates the point that is being measured, and the user can read the range to that point with precision of better than 0.1%.

  20. Light beam range finder

    DOEpatents

    McEwan, T.E.

    1998-06-16

    A ``laser tape measure`` for measuring distance is disclosed which includes a transmitter such as a laser diode which transmits a sequence of electromagnetic pulses in response to a transmit timing signal. A receiver samples reflections from objects within the field of the sequence of visible electromagnetic pulses with controlled timing, in response to a receive timing signal. The receiver generates a sample signal in response to the samples which indicates distance to the object causing the reflections. The timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the reflection such that the time between transmission of pulses in the sequence in sampling by the receiver sweeps over a range of delays. The transmit timing signal causes the transmitter to transmit the sequence of electromagnetic pulses at a pulse repetition rate, and the received timing signal sweeps over the range of delays in a sweep cycle such that reflections are sampled at the pulse repetition rate and with different delays in the range of delays, such that the sample signal represents received reflections in equivalent time. The receiver according to one aspect of the invention includes an avalanche photodiode and a sampling gate coupled to the photodiode which is responsive to the received timing signal. The transmitter includes a laser diode which supplies a sequence of visible electromagnetic pulses. A bright spot projected on to the target clearly indicates the point that is being measured, and the user can read the range to that point with precision of better than 0.1%. 7 figs.

  1. Effect of processing conditions on oil point pressure of moringa oleifera seed.

    PubMed

    Aviara, N A; Musa, W B; Owolarafe, O K; Ogunsina, B S; Oluwole, F A

    2015-07-01

    Seed oil expression is an important economic venture in rural Nigeria. The traditional techniques of carrying out the operation is not only energy sapping and time consuming but also wasteful. In order to reduce the tedium involved in the expression of oil from moringa oleifera seed and develop efficient equipment for carrying out the operation, the oil point pressure of the seed was determined under different processing conditions using a laboratory press. The processing conditions employed were moisture content (4.78, 6.00, 8.00 and 10.00 % wet basis), heating temperature (50, 70, 85 and 100 °C) and heating time (15, 20, 25 and 30 min). Results showed that the oil point pressure increased with increase in seed moisture content, but decreased with increase in heating temperature and heating time within the above ranges. Highest oil point pressure value of 1.1239 MPa was obtained at the processing conditions of 10.00 % moisture content, 50 °C heating temperature and 15 min heating time. The lowest oil point pressure obtained was 0.3164 MPa and it occurred at the moisture content of 4.78 %, heating temperature of 100 °C and heating time of 30 min. Analysis of Variance (ANOVA) showed that all the processing variables and their interactions had significant effect on the oil point pressure of moringa oleifera seed at 1 % level of significance. This was further demonstrated using Response Surface Methodology (RSM). Tukey's test and Duncan's Multiple Range Analysis successfully separated the means and a multiple regression equation was used to express the relationship existing between the oil point pressure of moringa oleifera seed and its moisture content, processing temperature, heating time and their interactions. The model yielded coefficients that enabled the oil point pressure of the seed to be predicted with very high coefficient of determination.

  2. Factors That Predict Time to In-Field Employment of Associate Degree Graduates: A Study of One College in the Technical College System of Georgia

    ERIC Educational Resources Information Center

    Futch, Karon Wilkerson

    2014-01-01

    This regression study examined the set of graduate characteristics (age, gender, ethnicity), as well as Grade Point Average Motivation, and environmental factors (program of study, use of career services, internship completion, Grade Point Average) that predicted time to in-field employment among associate degree graduates. Graduates ranging from…

  3. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    NASA Astrophysics Data System (ADS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-11-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.

  4. APOLLO clock performance and normal point corrections

    NASA Astrophysics Data System (ADS)

    Liang, Y.; Murphy, T. W., Jr.; Colmenares, N. R.; Battat, J. B. R.

    2017-12-01

    The Apache point observatory lunar laser-ranging operation (APOLLO) has produced a large volume of high-quality lunar laser ranging (LLR) data since it began operating in 2006. For most of this period, APOLLO has relied on a GPS-disciplined, high-stability quartz oscillator as its frequency and time standard. The recent addition of a cesium clock as part of a timing calibration system initiated a comparison campaign between the two clocks. This has allowed correction of APOLLO range measurements—called normal points—during the overlap period, but also revealed a mechanism to correct for systematic range offsets due to clock errors in historical APOLLO data. Drift of the GPS clock on  ∼1000 s timescales contributed typically 2.5 mm of range error to APOLLO measurements, and we find that this may be reduced to  ∼1.6 mm on average. We present here a characterization of APOLLO clock errors, the method by which we correct historical data, and the resulting statistics.

  5. About plasma points' generation in Z-pinch

    NASA Astrophysics Data System (ADS)

    Afonin, V. I.; Potapov, A. V.; Lazarchuk, V. P.; Murugov, V. M.; Senik, A. V.

    1997-05-01

    The streak tube study results (at visible and x-ray ranges) of dynamics of fast Z-pinch formed at explosion of metal wire in diode of high current generator are presented. Amplitude of current in the load reached ˜180 kA at increase time ˜50 ns. The results' analysis points to capability of controlling hot plasma points generation process in Z-pinch.

  6. Segmentation of time series with long-range fractal correlations.

    PubMed

    Bernaola-Galván, P; Oliver, J L; Hackenberg, M; Coronado, A V; Ivanov, P Ch; Carpena, P

    2012-06-01

    Segmentation is a standard method of data analysis to identify change-points dividing a nonstationary time series into homogeneous segments. However, for long-range fractal correlated series, most of the segmentation techniques detect spurious change-points which are simply due to the heterogeneities induced by the correlations and not to real nonstationarities. To avoid this oversegmentation, we present a segmentation algorithm which takes as a reference for homogeneity, instead of a random i.i.d. series, a correlated series modeled by a fractional noise with the same degree of correlations as the series to be segmented. We apply our algorithm to artificial series with long-range correlations and show that it systematically detects only the change-points produced by real nonstationarities and not those created by the correlations of the signal. Further, we apply the method to the sequence of the long arm of human chromosome 21, which is known to have long-range fractal correlations. We obtain only three segments that clearly correspond to the three regions of different G + C composition revealed by means of a multi-scale wavelet plot. Similar results have been obtained when segmenting all human chromosome sequences, showing the existence of previously unknown huge compositional superstructures in the human genome.

  7. Analysis of One-Way Laser Ranging Data to LRO, Time Transfer and Clock Characterization

    NASA Technical Reports Server (NTRS)

    Bauer, S.; Hussmann, H.; Oberst, J.; Dirkx, D.; Mao, D.; Neumann, G. A.; Mazarico, E.; Torrence, M. H.; McGarry, J. F.; Smith, D. E.; hide

    2016-01-01

    We processed and analyzed one-way laser ranging data from International Laser Ranging Service ground stations to NASA's Lunar Reconnaissance Orbiter (LRO), obtained from June 13, 2009 until September 30, 2014. We pair and analyze the one-way range observables from station laser fire and spacecraft laser arrival times by using nominal LRO orbit models based on the GRAIL gravity field. We apply corrections for instrument range walk, as well as for atmospheric and relativistic effects. In total we derived a tracking data volume of approximately 3000 hours featuring 64 million Full Rate and 1.5 million Normal Point observations. From a statistical analysis of the dataset we evaluate the experiment and the ground station performance. We observe a laser ranging measurement precision of 12.3 centimeters in case of the Full Rate data which surpasses the LOLA (Lunar Orbiting Laser Altimeter) timestamp precision of 15 centimeters. The averaging to Normal Point data further reduces the measurement precision to 5.6 centimeters. We characterized the LRO clock with fits throughout the mission time and estimated the rate to 6.9 times10 (sup -8), the aging to 1.6 times 10 (sup -12) per day and the change of aging to 2.3 times 10 (sup -14) per day squared over all mission phases. The fits also provide referencing of onboard time to the TDB (Barycentric Dynamical Time) time scale at a precision of 166 nanoseconds over two and 256 nanoseconds over all mission phases, representing ground to space time transfer. Furthermore we measure ground station clock differences from the fits as well as from simultaneous passes which we use for ground to ground time transfer from common view observations. We observed relative offsets ranging from 33 to 560 nanoseconds and relative rates ranging from 2 times 10 (sup -13) to 6 times 10 (sup -12) between the ground station clocks during selected mission phases. We study the results from the different methods and discuss their applicability for time transfer.

  8. Projectile Motion Revisited.

    ERIC Educational Resources Information Center

    Lucie, Pierre

    1979-01-01

    Analyzes projectile motion using symmetry and simple geometry. Deduces the direction of velocity at any point, range, time of flight, maximum height, safety parabola, and maximum range for a projectile launched upon a plane inclined at any angle with respect to the horizontal. (Author/GA)

  9. Tests of Gravity Using Lunar Laser Ranging.

    PubMed

    Merkowitz, Stephen M

    2010-01-01

    Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the past four decades. The three retroreflector arrays put on the Moon by the Apollo astronauts and the French built arrays on the Soviet Lunokhod rovers continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point 3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly, it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retroreflectors are limiting the precision of the range measurements. In this article, we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.

  10. Tests of gravity Using Lunar Laser Ranging

    NASA Technical Reports Server (NTRS)

    Merkowitz, Stephen M.

    2010-01-01

    Lunar laser ranging (LLR) has been a workhorse for testing general relativity over the pat four decades. The three retrorefiector arrays put on the Moon by the Apollo astronauts and the French built array on the second Soviet Lunokhod rover continue to be useful targets, and have provided the most stringent tests of the Strong Equivalence Principle and the time variation of Newton's gravitational constant. The relatively new ranging system at the Apache Point :3.5 meter telescope now routinely makes millimeter level range measurements. Incredibly. it has taken 40 years for ground station technology to advance to the point where characteristics of the lunar retrorefiectors are limiting the precision of the range measurements. In this article. we review the gravitational science and technology of lunar laser ranging and discuss prospects for the future.

  11. Point discharge current measurements beneath dust devils

    USDA-ARS?s Scientific Manuscript database

    We document for the first time observations of point discharge currents under dust devils using a novel compact sensor deployed in summer 2016 at the USDA-ARS Jornada Experimental Range in New Mexico, USA. A consistent signature is noted in about a dozen events seen over 40 days, with a positive cur...

  12. Variability and Comprehensiveness of North American Online Available Physical Therapy Protocols Following Hip Arthroscopy for Femoroacetabular Impingement and Labral Repair.

    PubMed

    Cvetanovich, Gregory L; Lizzio, Vincent; Meta, Fabien; Chan, Derek; Zaltz, Ira; Nho, Shane J; Makhni, Eric C

    2017-11-01

    To assess comprehensiveness and variability of postoperative physical therapy protocols published online following hip arthroscopy for femoroacetabular impingement (FAI) and/or labral repair. Surgeons were identified by the International Society for Hip Arthroscopy "Find a Surgeon" feature in North America (http://www.isha.net/members/, search August 10, 2016). Exclusion criteria included nonsurgeons and protocols for conditions other than hip arthroscopy for FAI and/or labral tear. Protocols were identified by review of surgeons' personal and departmental websites and evaluated for postoperative restrictions, rehabilitation components, and the time points for ending restrictions and initiating activities. Of 111 surgeons available online, 31 (27.9%) had postoperative hip arthroscopy physical therapy protocols available online. Bracing was used in 54.8% (17/31) of protocols for median 2-week duration (range, 1-6 weeks). Most protocols specified the initial postoperative weight-bearing status (29/31, 93.5%), most frequently partial weight-bearing with 20 pounds foot flat (20/29, 69.0%). The duration of weight-bearing restriction was median 3 weeks (range, 2-6) for FAI and median 6 weeks (range, 3-8) for microfracture. The majority of protocols specified initial range of motion limitations (26/31, 83.9%) for median 3 weeks (range, 1.5-12). There was substantial variation in the rehabilitation activities and time points for initiating activities. Time to return to running was specified by 20/31 (64.5%) protocols at median 12 weeks (range, 6-19), and return to sport timing was specified by 13/31 (41.9%) protocols at median 15.5 weeks (range, 9-23). There is considerable variability in postoperative physical therapy protocols available online following hip arthroscopy for FAI, including postoperative restrictions, rehabilitation activities, and time points for activities. This information offers residents, fellows, and established hip arthroscopists a centralized comparison of publicly available physical therapy protocols following hip arthroscopy. Practicing arthroscopists might find this analysis useful to compare various therapy strategies to their own recommendations. The variability we report can also provide inspiration for future efficacy research toward a more standard rehabilitation. Copyright © 2017. Published by Elsevier Inc.

  13. 40 CFR 461.31 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS BATTERY MANUFACTURING POINT SOURCE CATEGORY Lead Subcategory....860 0.410 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (5) Subpart C—Battery Wash (with... Within the range of 7.5 to 10.0 at all times. (6) Subpart C—Battery Wash (Water Only). BPT Effluent...

  14. 40 CFR 461.31 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) BATTERY MANUFACTURING POINT SOURCE CATEGORY Lead....860 0.410 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (5) Subpart C—Battery Wash (with... Within the range of 7.5 to 10.0 at all times. (6) Subpart C—Battery Wash (Water Only). BPT Effluent...

  15. 40 CFR 461.31 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) BATTERY MANUFACTURING POINT SOURCE CATEGORY Lead....860 0.410 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (5) Subpart C—Battery Wash (with... Within the range of 7.5 to 10.0 at all times. (6) Subpart C—Battery Wash (Water Only). BPT Effluent...

  16. 40 CFR 461.31 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS BATTERY MANUFACTURING POINT SOURCE CATEGORY Lead Subcategory....860 0.410 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (5) Subpart C—Battery Wash (with... Within the range of 7.5 to 10.0 at all times. (6) Subpart C—Battery Wash (Water Only). BPT Effluent...

  17. 40 CFR 461.31 - Effluent limitations representing the degree of effluent reduction attainable by the application...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS (CONTINUED) BATTERY MANUFACTURING POINT SOURCE CATEGORY Lead....860 0.410 pH (1) (1) 1 Within the range of 7.5 to 10.0 at all times. (5) Subpart C—Battery Wash (with... Within the range of 7.5 to 10.0 at all times. (6) Subpart C—Battery Wash (Water Only). BPT Effluent...

  18. Estimating vehicle height using homographic projections

    DOEpatents

    Cunningham, Mark F; Fabris, Lorenzo; Gee, Timothy F; Ghebretati, Jr., Frezghi H; Goddard, James S; Karnowski, Thomas P; Ziock, Klaus-peter

    2013-07-16

    Multiple homography transformations corresponding to different heights are generated in the field of view. A group of salient points within a common estimated height range is identified in a time series of video images of a moving object. Inter-salient point distances are measured for the group of salient points under the multiple homography transformations corresponding to the different heights. Variations in the inter-salient point distances under the multiple homography transformations are compared. The height of the group of salient points is estimated to be the height corresponding to the homography transformation that minimizes the variations.

  19. Heat-Transfer Measurements on a 5.5- Inch-Diameter Hemispherical Concave Nose in Free Flight at Mach Numbers up to 6.6

    NASA Technical Reports Server (NTRS)

    Levine, Jack; Rumsey, Charles B.

    1958-01-01

    The aerodynamic heat transfer to a hemispherical concave nose has been measured in free flight at Mach numbers from 3.5 to 6.6 with corresponding Reynolds numbers based on nose diameter from 7.4 x 10(exp 6) to 14 x 10(exp 6). Over the test Mach number range the heating on the cup nose, expressed as a ratio to the theoretical stagnation-point heating on a hemisphere nose of the same diameter, varied from 0.05 to 0.13 at the stagnation point of the cup, was approximately 0.1 at other locations within 40 deg of the stagnation point, and varied from 0.6 to 0.8 just inside the lip where the highest heating rates occurred. At a Mach number of 5 the total heat input integrated over the surface of the cup nose including the lip was 0.55 times the theoretical value for a hemisphere nose with laminar boundary layer and 0.76 times that for a flat face. The heating at the stagnation point was approximately 1/5 as great as steady-flow tunnel results. Extremely high heating rates at the stagnation point (on the order of 30 times the stagnation-point values of the present test), which have occurred in conjunction with unsteady oscillatory flow around cup noses in wind-tunnel tests at Mach and Reynolds numbers within the present test range, were not observed.

  20. Chirp-Z analysis for sol-gel transition monitoring.

    PubMed

    Martinez, Loïc; Caplain, Emmanuel; Serfaty, Stéphane; Griesmar, Pascal; Gouedard, Gérard; Gindre, Marcel

    2004-04-01

    Gelation is a complex reaction that transforms a liquid medium into a solid one: the gel. In gel state, some gel materials (DMAP) have the singular property to ring in an audible frequency range when a pulse is applied. Before the gelation point, there is no transmission of slow waves observed; after the gelation point, the speed of sound in the gel rapidly increases from 0.1 to 10 m/s. The time evolution of the speed of sound can be measured, in frequency domain, by following the frequency spacing of the resonance peaks from the Synchronous Detection (SD) measurement method. Unfortunately, due to a constant frequency sampling rate, the relative error for low speeds (0.1 m/s) is 100%. In order to maintain a low constant relative error, in the whole speed time evolution range, Chirp-Z Transform (CZT) is used. This operation transforms a time variant signal to a time invariant one using only a time dependant stretching factor (S). In the frequency domain, the CZT enables us to stretch each collected spectrum from time signals. The blind identification of the S factor gives us the complete time evolution law of the speed of sound. Moreover, this method proves that the frequency bandwidth follows the same time law. These results point out that the minimum wavelength stays constant and that it only depends on the gel.

  1. LiDAR-IMU Time Delay Calibration Based on Iterative Closest Point and Iterated Sigma Point Kalman Filter.

    PubMed

    Liu, Wanli

    2017-03-08

    The time delay calibration between Light Detection and Ranging (LiDAR) and Inertial Measurement Units (IMUs) is an essential prerequisite for its applications. However, the correspondences between LiDAR and IMU measurements are usually unknown, and thus cannot be computed directly for the time delay calibration. In order to solve the problem of LiDAR-IMU time delay calibration, this paper presents a fusion method based on iterative closest point (ICP) and iterated sigma point Kalman filter (ISPKF), which combines the advantages of ICP and ISPKF. The ICP algorithm can precisely determine the unknown transformation between LiDAR-IMU; and the ISPKF algorithm can optimally estimate the time delay calibration parameters. First of all, the coordinate transformation from the LiDAR frame to the IMU frame is realized. Second, the measurement model and time delay error model of LiDAR and IMU are established. Third, the methodology of the ICP and ISPKF procedure is presented for LiDAR-IMU time delay calibration. Experimental results are presented that validate the proposed method and demonstrate the time delay error can be accurately calibrated.

  2. Automatic Modelling of Rubble Mound Breakwaters from LIDAR Data

    NASA Astrophysics Data System (ADS)

    Bueno, M.; Díaz-Vilariño, L.; González-Jorge, H.; Martínez-Sánchez, J.; Arias, P.

    2015-08-01

    Rubble mound breakwaters maintenance is critical to the protection of beaches and ports. LiDAR systems provide accurate point clouds from the emerged part of the structure that can be modelled to make it more useful and easy to handle. This work introduces a methodology for the automatic modelling of breakwaters with armour units of cube shape. The algorithm is divided in three main steps: normal vector computation, plane segmentation, and cube reconstruction. Plane segmentation uses the normal orientation of the points and the edge length of the cube. Cube reconstruction uses the intersection of three perpendicular planes and the edge length. Three point clouds cropped from the main point cloud of the structure are used for the tests. The number of cubes detected is around 56 % for two of the point clouds and 32 % for the third one over the total physical cubes. Accuracy assessment is done by comparison with manually drawn cubes calculating the differences between the vertexes. It ranges between 6.4 cm and 15 cm. Computing time ranges between 578.5 s and 8018.2 s. The computing time increases with the number of cubes and the requirements of collision detection.

  3. Extensible 3D (X3D) Graphics for Visualizing Marine Mammal Reaction to Underwater Sound on the Southern California ASW Range (SOAR)

    DTIC Science & Technology

    2007-06-01

    file ARC- 20060811T130816.txt, where color is used to represent points in time (red being the earliest, transitioning to orange, yellow , then white...Administration (NOAA), using passive hydrophone arrays along the mid-Atlantic ridge to listen for underwater earthquakes and volcanoes , have found that a...appeared. The earliest data points were designated red, and later points were shades of orange and yellow , until the last points (relative to the

  4. Segmentation of time series with long-range fractal correlations

    PubMed Central

    Bernaola-Galván, P.; Oliver, J.L.; Hackenberg, M.; Coronado, A.V.; Ivanov, P.Ch.; Carpena, P.

    2012-01-01

    Segmentation is a standard method of data analysis to identify change-points dividing a nonstationary time series into homogeneous segments. However, for long-range fractal correlated series, most of the segmentation techniques detect spurious change-points which are simply due to the heterogeneities induced by the correlations and not to real nonstationarities. To avoid this oversegmentation, we present a segmentation algorithm which takes as a reference for homogeneity, instead of a random i.i.d. series, a correlated series modeled by a fractional noise with the same degree of correlations as the series to be segmented. We apply our algorithm to artificial series with long-range correlations and show that it systematically detects only the change-points produced by real nonstationarities and not those created by the correlations of the signal. Further, we apply the method to the sequence of the long arm of human chromosome 21, which is known to have long-range fractal correlations. We obtain only three segments that clearly correspond to the three regions of different G + C composition revealed by means of a multi-scale wavelet plot. Similar results have been obtained when segmenting all human chromosome sequences, showing the existence of previously unknown huge compositional superstructures in the human genome. PMID:23645997

  5. [Automated analyzer of enzyme immunoassay].

    PubMed

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  6. User and technical documentation

    NASA Astrophysics Data System (ADS)

    1988-09-01

    The program LIBRATE calculates velocities for trajectories from low earth orbit (LEO) to four of the five libration points (L2, L3, L4, and L5), and from low lunar orbit (LLO) to libration points L1 and L2. The flight to be analyzed departs from a circular orbit of any altitude and inclination about the Earth or Moon and finishes in a circular orbit about the Earth at the desired libration point within a specified flight time. This program produces a matrix of the delta V's needed to complete the desired flight. The user specifies the departure orbit, and the maximum flight time. A matrix is then developed with 10 inclinations, ranging from 0 to 90 degrees, forming the columns, and 19 possible flight times, ranging from the flight time (input) to 36 hours less than the input value, in decrements of 2 hours, forming the rows. This matrix is presented in three different reports including the total delta V's, and both of the delta V components discussed. The input required from the user to define the flight is discussed. The contents of the three reports that are produced as outputs are also described. The instructions are also included which are needed to execute the program.

  7. One-stage metatarsal lengthening by allograft interposition: a novel approach for congenital brachymetatarsia.

    PubMed

    Giannini, Sandro; Faldini, Cesare; Pagkrati, Stavroula; Miscione, Maria Teresa; Luciani, Deianira

    2010-07-01

    Congenital brachymetatarsia, a shortened metatarsal bone, can be corrected surgically by callus distraction or one-stage lengthening using bone graft. We asked whether one-stage metatarsal lengthening using metatarsal homologous bone graft could improve forefoot function, lead to metatarsal healing, restore metatarsal parabola, and improve cosmetic appearance. We retrospectively reviewed 29 patients (41 feet) in whom we lengthened 50 metatarsals. Surgery consisted of a transverse proximal osteotomy of the metatarsal shaft and interposition of a metatarsal homologous bone graft (average, 13 mm long) fixed with an intramedullary Kirschner wire. Minimum followup was 3 years (mean, 5 years; range, 3-11 years). Bone union was achieved in all cases. The mean preoperative American Orthopaedic Foot and Ankle Society score was 37 points (range, 28-53 points) and the mean postoperative score was 88 points (range, 74-96 points), with an average improvement of 51 points. Radiographically, the mean gain in length was 13 mm (range, 10-15 mm), and the mean percentage increase was 23%. One-stage metatarsal lengthening using interposition of metatarsal homologous bone graft to correct congenital brachymetatarsia has low morbidity for the patient, limited complications, short recovery times, and restores forefoot anatomy. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  8. Comparison of breast DCE-MRI contrast time points for predicting response to neoadjuvant chemotherapy using deep convolutional neural network features with transfer learning

    NASA Astrophysics Data System (ADS)

    Huynh, Benjamin Q.; Antropova, Natasha; Giger, Maryellen L.

    2017-03-01

    DCE-MRI datasets have a temporal aspect to them, resulting in multiple regions of interest (ROIs) per subject, based on contrast time points. It is unclear how the different contrast time points vary in terms of usefulness for computer-aided diagnosis tasks in conjunction with deep learning methods. We thus sought to compare the different DCE-MRI contrast time points with regard to how well their extracted features predict response to neoadjuvant chemotherapy within a deep convolutional neural network. Our dataset consisted of 561 ROIs from 64 subjects. Each subject was categorized as a non-responder or responder, determined by recurrence-free survival. First, features were extracted from each ROI using a convolutional neural network (CNN) pre-trained on non-medical images. Linear discriminant analysis classifiers were then trained on varying subsets of these features, based on their contrast time points of origin. Leave-one-out cross validation (by subject) was used to assess performance in the task of estimating probability of response to therapy, with area under the ROC curve (AUC) as the metric. The classifier trained on features from strictly the pre-contrast time point performed the best, with an AUC of 0.85 (SD = 0.033). The remaining classifiers resulted in AUCs ranging from 0.71 (SD = 0.028) to 0.82 (SD = 0.027). Overall, we found the pre-contrast time point to be the most effective at predicting response to therapy and that including additional contrast time points moderately reduces variance.

  9. A new comparison method for dew-point generators

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    1999-12-01

    A new method for comparing dew-point generators was developed at the Centre for Metrology and Accreditation. In this method, the generators participating in a comparison are compared with a transportable saturator unit using a dew-point comparator. The method was tested by constructing a test apparatus and by comparing it with the MIKES primary dew-point generator several times in the dew-point temperature range from -40 to +75 °C. The expanded uncertainty (k = 2) of the apparatus was estimated to be between 0.05 and 0.07 °C and the difference between the comparator system and the generator is well within these limits. In particular, all of the results obtained in the range below 0 °C are within ±0.03 °C. It is concluded that a new type of a transfer standard with characteristics most suitable for dew-point comparisons can be developed on the basis of the principles presented in this paper.

  10. Validity of Willingness to Pay Measures under Preference Uncertainty.

    PubMed

    Braun, Carola; Rehdanz, Katrin; Schmidt, Ulrich

    2016-01-01

    Recent studies in the marketing literature developed a new method for eliciting willingness to pay (WTP) with an open-ended elicitation format: the Range-WTP method. In contrast to the traditional approach of eliciting WTP as a single value (Point-WTP), Range-WTP explicitly allows for preference uncertainty in responses. The aim of this paper is to apply Range-WTP to the domain of contingent valuation and to test for its theoretical validity and robustness in comparison to the Point-WTP. Using data from two novel large-scale surveys on the perception of solar radiation management (SRM), a little-known technique for counteracting climate change, we compare the performance of both methods in the field. In addition to the theoretical validity (i.e. the degree to which WTP values are consistent with theoretical expectations), we analyse the test-retest reliability and stability of our results over time. Our evidence suggests that the Range-WTP method clearly outperforms the Point-WTP method.

  11. Validity of Willingness to Pay Measures under Preference Uncertainty

    PubMed Central

    Braun, Carola; Rehdanz, Katrin; Schmidt, Ulrich

    2016-01-01

    Recent studies in the marketing literature developed a new method for eliciting willingness to pay (WTP) with an open-ended elicitation format: the Range-WTP method. In contrast to the traditional approach of eliciting WTP as a single value (Point-WTP), Range-WTP explicitly allows for preference uncertainty in responses. The aim of this paper is to apply Range-WTP to the domain of contingent valuation and to test for its theoretical validity and robustness in comparison to the Point-WTP. Using data from two novel large-scale surveys on the perception of solar radiation management (SRM), a little-known technique for counteracting climate change, we compare the performance of both methods in the field. In addition to the theoretical validity (i.e. the degree to which WTP values are consistent with theoretical expectations), we analyse the test-retest reliability and stability of our results over time. Our evidence suggests that the Range-WTP method clearly outperforms the Point-WTP method. PMID:27096163

  12. Analysis of Sample Size, Counting Time, and Plot Size from an Avian Point Count Survey on Hoosier National Forest, Indiana

    Treesearch

    Frank R. Thompson; Monica J. Schwalbach

    1995-01-01

    We report results of a point count survey of breeding birds on Hoosier National Forest in Indiana. We determined sample size requirements to detect differences in means and the effects of count duration and plot size on individual detection rates. Sample size requirements ranged from 100 to >1000 points with Type I and II error rates of <0.1 and 0.2. Sample...

  13. Laser-photodetector timing station instruction and maintenance manual

    NASA Technical Reports Server (NTRS)

    Strader, E. A.

    1986-01-01

    A laser photodetector station is used for detecting the arrival of a projectile at a specific point along a ballistic range. The system can be employed on either an open or evacuated range, with small projectiles, and at hypervelocities. The setup procedures, maintenance, and system components are described.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Biasotto, G.; Simoes, A.Z., E-mail: alezipo@yahoo.com; Foschini, C.R.

    Highlights: Black-Right-Pointing-Pointer BiFeO{sub 3} (BFO) nanoparticles were grown by hydrothermal microwave method (HTMW). Black-Right-Pointing-Pointer The soaking time is effective in improving phase formation. Black-Right-Pointing-Pointer Rietveld refinement reveals an orthorhombic structure. Black-Right-Pointing-Pointer The observed magnetism of the BFO crystallites is a consequence of particle size. Black-Right-Pointing-Pointer The HTMW is a genuine technique for low temperatures and short times of synthesis. -- Abstract: Hydrothermal microwave method (HTMW) was used to synthesize crystalline bismuth ferrite (BiFeO{sub 3}) nanoparticles (BFO) in the temperature of 180 Degree-Sign C with times ranging from 5 min to 1 h. BFO nanoparticles were characterized by means of X-raymore » analyses, FT-IR, Raman spectroscopy, TG-DTA and FE-SEM. X-ray diffraction results indicated that longer soaking time was benefit to refraining the formation of any impurity phases and growing BFO crystallites into almost single-phase perovskites. Typical FT-IR spectra for BFO nanoparticles presented well defined bands, indicating a substantial short-range order in the system. TG-DTA analyses confirmed the presence of lattice OH{sup -} groups, commonly found in materials obtained by HTMW process. Compared with the conventional solid-state reaction process, submicron BFO crystallites with better homogeneity could be produced at the temperature as low as 180 Degree-Sign C. These results show that the HTMW synthesis route is rapid, cost effective, and could be used as an alternative to obtain BFO nanoparticles in the temperature of 180 Degree-Sign C for 1 h.« less

  15. Trajectories of marital, parent-child, and sibling conflict during pediatric cancer treatment.

    PubMed

    Katz, Lynn Fainsilber; Fladeboe, Kaitlyn; Lavi, Iris; King, Kevin; Kawamura, Joy; Friedman, Debra; Compas, Bruce; Breiger, David; Lengua, Liliana; Gurtovenko, Kyrill; Stettler, Nicole

    2018-05-28

    The stress of having a child with cancer can impact the quality of relationships within the family. The current study describes the longitudinal trajectory of marital, parent-child, and sibling conflict beginning around the time of diagnosis through the first year of treatment. We examined the average level of marital, parent-child, and sibling conflict at each monthly time point in the first year of treatment; the proportion of families that fall into the distressed range of marital, parent-child, and sibling conflict at each time point; the typical trajectory of conflict during the first year of treatment and whether there are differences in trajectories across families. A total of 160 families of children newly diagnosed with cancer (Mage = 5.6 years; range = 2-18 years) participated in a short-term prospective longitudinal study. Primary caregivers provided monthly reports of marital, parent-child, and sibling conflict. Using multilevel modeling (MLM), most families showed stability in quality of family relationships, although considerable between-family variability was observed. For married couples, 25-36% of couples were in the distressed range at one time point over the first year of treatment. For married couples, more distress occurred at earlier months, particularly month 3. For parent-child and sibling dyads, the most difficult time periods were during later months. Implications for development of interventions that target at-risk family relationships are discussed. Identifying processes that predict between-family variability in trajectories of family relationships is an important next step, particularly for the marital relationship. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  16. Investigation of Multiple Frequency Ranges Using Discrete Wavelet Decomposition of Resting-State Functional Connectivity in Mild Traumatic Brain Injury Patients

    PubMed Central

    Chen, Haoxing; Roys, Steven; Zhuo, Jiachen; Varshney, Amitabh; Gullapalli, Rao P.

    2015-01-01

    Abstract The aim of this study was to investigate if discrete wavelet decomposition provides additional insight into resting-state processes through the analysis of functional connectivity within specific frequency ranges within the default mode network (DMN) that may be affected by mild traumatic brain injury (mTBI). Participants included 32 mTBI patients (15 with postconcussive syndrome [PCS+] and 17 without [PCS−]). mTBI patients received resting-state functional magnetic resonance imaging (rs-fMRI) at acute (within 10 days of injury) and chronic (6 months postinjury) time points and were compared with 31 controls (healthy control [HC]). The wavelet decomposition divides the time series into multiple frequency ranges based on four scaling factors (SF1: 0.125–0.250 Hz, SF2: 0.060–0.125 Hz, SF3: 0.030–0.060 Hz, SF4: 0.015–0.030 Hz). Within each SF, wavelet connectivity matrices for nodes of the DMN were created for each group (HC, PCS+, PCS−), and bivariate measures of strength and diversity were calculated. The results demonstrate reduced strength of connectivity in PCS+ patients compared with PCS− patients within SF1 during both the acute and chronic stages of injury, as well as recovery of connectivity within SF1 across the two time points. Furthermore, the PCS− group demonstrated greater network strength compared with controls at both time points, suggesting a potential compensatory or protective mechanism in these patients. These findings stress the importance of investigating resting-state connectivity within multiple frequency ranges; however, many of our findings are within SF1, which may overlap with frequencies associated with cardiac and respiratory activities. PMID:25808612

  17. Investigation of Multiple Frequency Ranges Using Discrete Wavelet Decomposition of Resting-State Functional Connectivity in Mild Traumatic Brain Injury Patients.

    PubMed

    Sours, Chandler; Chen, Haoxing; Roys, Steven; Zhuo, Jiachen; Varshney, Amitabh; Gullapalli, Rao P

    2015-09-01

    The aim of this study was to investigate if discrete wavelet decomposition provides additional insight into resting-state processes through the analysis of functional connectivity within specific frequency ranges within the default mode network (DMN) that may be affected by mild traumatic brain injury (mTBI). Participants included 32 mTBI patients (15 with postconcussive syndrome [PCS+] and 17 without [PCS-]). mTBI patients received resting-state functional magnetic resonance imaging (rs-fMRI) at acute (within 10 days of injury) and chronic (6 months postinjury) time points and were compared with 31 controls (healthy control [HC]). The wavelet decomposition divides the time series into multiple frequency ranges based on four scaling factors (SF1: 0.125-0.250 Hz, SF2: 0.060-0.125 Hz, SF3: 0.030-0.060 Hz, SF4: 0.015-0.030 Hz). Within each SF, wavelet connectivity matrices for nodes of the DMN were created for each group (HC, PCS+, PCS-), and bivariate measures of strength and diversity were calculated. The results demonstrate reduced strength of connectivity in PCS+ patients compared with PCS- patients within SF1 during both the acute and chronic stages of injury, as well as recovery of connectivity within SF1 across the two time points. Furthermore, the PCS- group demonstrated greater network strength compared with controls at both time points, suggesting a potential compensatory or protective mechanism in these patients. These findings stress the importance of investigating resting-state connectivity within multiple frequency ranges; however, many of our findings are within SF1, which may overlap with frequencies associated with cardiac and respiratory activities.

  18. A single-chip 32-channel analog beamformer with 4-ns delay resolution and 768-ns maximum delay range for ultrasound medical imaging with a linear array transducer.

    PubMed

    Um, Ji-Yong; Kim, Yoon-Jee; Cho, Seong-Eun; Chae, Min-Kyun; Kim, Byungsub; Sim, Jae-Yoon; Park, Hong-June

    2015-02-01

    A single-chip 32-channel analog beamformer is proposed. It achieves a delay resolution of 4 ns and a maximum delay range of 768 ns. It has a focal-point based architecture, which consists of 7 sub-analog beamformers (sub-ABF). Each sub-ABF performs a RX focusing operation for a single focal point. Seven sub-ABFs perform a time-interleaving operation to achieve the maximum delay range of 768 ns. Phase interpolators are used in sub-ABFs to generate sampling clocks with the delay resolution of 4 ns from a low frequency system clock of 5 MHz. Each sub-ABF samples 32 echo signals at different times into sampling capacitors, which work as analog memory cells. The sampled 32 echo signals of each sub-ABF are originated from one target focal point at one instance. They are summed at one instance in a sub-ABF to perform the RX focusing for the target focal point. The proposed ABF chip has been fabricated in a 0.13- μ m CMOS process with an active area of 16 mm (2). The total power consumption is 287 mW. In measurement, the digital echo signals from a commercial ultrasound medical imaging machine were applied to the fabricated chip through commercial DAC chips. Due to the speed limitation of the DAC chips, the delay resolution was relaxed to 10 ns for the real-time measurement. A linear array transducer with no steering operation is used in this work.

  19. Simple tunnel diode circuit for accurate zero crossing timing

    NASA Technical Reports Server (NTRS)

    Metz, A. J.

    1969-01-01

    Tunnel diode circuit, capable of timing the zero crossing point of bipolar pulses, provides effective design for a fast crossing detector. It combines a nonlinear load line with the diode to detect the zero crossing of a wide range of input waveshapes.

  20. Automatic image fusion of real-time ultrasound with computed tomography images: a prospective comparison between two auto-registration methods.

    PubMed

    Cha, Dong Ik; Lee, Min Woo; Kim, Ah Yeong; Kang, Tae Wook; Oh, Young-Taek; Jeong, Ja-Yeon; Chang, Jung-Woo; Ryu, Jiwon; Lee, Kyong Joon; Kim, Jaeil; Bang, Won-Chul; Shin, Dong Kuk; Choi, Sung Jin; Koh, Dalkwon; Seo, Bong Koo; Kim, Kyunga

    2017-11-01

    Background A major drawback of conventional manual image fusion is that the process may be complex, especially for less-experienced operators. Recently, two automatic image fusion techniques called Positioning and Sweeping auto-registration have been developed. Purpose To compare the accuracy and required time for image fusion of real-time ultrasonography (US) and computed tomography (CT) images between Positioning and Sweeping auto-registration. Material and Methods Eighteen consecutive patients referred for planning US for radiofrequency ablation or biopsy for focal hepatic lesions were enrolled. Image fusion using both auto-registration methods was performed for each patient. Registration error, time required for image fusion, and number of point locks used were compared using the Wilcoxon signed rank test. Results Image fusion was successful in all patients. Positioning auto-registration was significantly faster than Sweeping auto-registration for both initial (median, 11 s [range, 3-16 s] vs. 32 s [range, 21-38 s]; P < 0.001] and complete (median, 34.0 s [range, 26-66 s] vs. 47.5 s [range, 32-90]; P = 0.001] image fusion. Registration error of Positioning auto-registration was significantly higher for initial image fusion (median, 38.8 mm [range, 16.0-84.6 mm] vs. 18.2 mm [6.7-73.4 mm]; P = 0.029), but not for complete image fusion (median, 4.75 mm [range, 1.7-9.9 mm] vs. 5.8 mm [range, 2.0-13.0 mm]; P = 0.338]. Number of point locks required to refine the initially fused images was significantly higher with Positioning auto-registration (median, 2 [range, 2-3] vs. 1 [range, 1-2]; P = 0.012]. Conclusion Positioning auto-registration offers faster image fusion between real-time US and pre-procedural CT images than Sweeping auto-registration. The final registration error is similar between the two methods.

  1. An Airlift Hub-and-Spoke Location-Routing Model with Time Windows: Case Study of the CONUS-to-Korea Airlift Problem

    DTIC Science & Technology

    1998-03-01

    a point of embarkation to a point of debarkation. This study develops an alternative hub-and-spoke combined location-routing integer linear...programming prototype model, and uses this model to determine what advantages a hub-and-spoke system offers, and in which scenarios it is better-suited than the...extension on the following works: the hierarchical model of Perl and Daskin (1983), time windows features of Chan (1991), combining subtour-breaking and range

  2. Influencing Factors of the Initiation Point in the Parachute-Bomb Dynamic Detonation System

    NASA Astrophysics Data System (ADS)

    Qizhong, Li; Ye, Wang; Zhongqi, Wang; Chunhua, Bai

    2017-12-01

    The parachute system has been widely applied in modern armament design, especially for the fuel-air explosives. Because detonation of fuel-air explosives occurs during flight, it is necessary to investigate the influences of the initiation point to ensure successful dynamic detonation. In fact, the initiating position exist the falling area in the fuels, due to the error of influencing factors. In this paper, the major influencing factors of initiation point were explored with airdrop and the regularity between initiation point area and factors were obtained. Based on the regularity, the volume equation of initiation point area was established to predict the range of initiation point in the fuel. The analysis results showed that the initiation point appeared area, scattered on account of the error of attitude angle, secondary initiation charge velocity, and delay time. The attitude angle was the major influencing factors on a horizontal axis. On the contrary, secondary initiation charge velocity and delay time were the major influencing factors on a horizontal axis. Overall, the geometries of initiation point area were sector coupled with the errors of the attitude angle, secondary initiation charge velocity, and delay time.

  3. High gain antenna pointing on the Mars Exploration Rovers

    NASA Technical Reports Server (NTRS)

    Vanelli, C. Anthony; Ali, Khaled S.

    2005-01-01

    This paper describes the algorithm used to point the high gain antennae on NASA/JPL's Mars Exploration Rovers. The gimballed antennae must track the Earth as it moves across the Martian sky during communication sessions. The algorithm accounts for (1) gimbal range limitations, (2) obstructions both on the rover and in the surrounding environment, (3) kinematic singularities in the gimbal design, and (4) up to two joint-space solutions for a given pointing direction. The algorithm computes the intercept-times for each of the occlusions and chooses the jointspace solution that provides the longest track time before encountering an occlusion. Upon encountering an occlusion, the pointing algorithm automatically switches to the other joint-space solution if it is not also occluded. The algorithm has successfully provided flop-free pointing for both rovers throughout the mission.

  4. Micro-vibration detection with heterodyne holography based on time-averaged method

    NASA Astrophysics Data System (ADS)

    Qin, XiaoDong; Pan, Feng; Chen, ZongHui; Hou, XueQin; Xiao, Wen

    2017-02-01

    We propose a micro-vibration detection method by introducing heterodyne interferometry to time-averaged holography. This method compensates for the deficiency of time-average holography in quantitative measurements and widens its range of application effectively. Acousto-optic modulators are used to modulate the frequencies of the reference beam and the object beam. Accurate detection of the maximum amplitude of each point in the vibration plane is performed by altering the frequency difference of both beams. The range of amplitude detection of plane vibration is extended. In the stable vibration mode, the distribution of the maximum amplitude of each point is measured and the fitted curves are plotted. Hence the plane vibration mode of the object is demonstrated intuitively and detected quantitatively. We analyzed the method in theory and built an experimental system with a sine signal as the excitation source and a typical piezoelectric ceramic plate as the target. The experimental results indicate that, within a certain error range, the detected vibration mode agrees with the intrinsic vibration characteristics of the object, thus proving the validity of this method.

  5. Use of point-of-sale data to assess food and nutrient quality in remote stores.

    PubMed

    Brimblecombe, Julie; Liddle, Robyn; O'Dea, Kerin

    2013-07-01

    To examine the feasibility of using point-of-sale data to assess dietary quality of food sales in remote stores. A multi-site cross-sectional assessment of food and nutrient composition of food sales. Point-of-sale data were linked to Australian Food and Nutrient Data and compared across study sites and with nutrient requirements. Remote Aboriginal Australia. Six stores. Point-of-sale data were readily available and provided a low-cost, efficient and objective assessment of food and nutrient sales. Similar patterns in macronutrient distribution, food expenditure and key food sources of nutrients were observed across stores. In all stores, beverages, cereal and cereal products, and meat and meat products comprised approximately half of food sales (range 49–57 %). Fruit and vegetable sales comprised 10.4 (SD 1.9) % on average. Carbohydrate contributed 54.4 (SD 3.0) % to energy; protein 13.5 (SD 1.1) %; total sugars 28.9 (SD 4.3) %; and the contribution of total saturated fat to energy ranged from 11.0 to 14.4% across stores. Mg, Ca, K and fibre were limiting nutrients, and Na was four to five times higher than the midpoint of the average intake range. Relatively few foods were major sources of nutrients. Point-of-sale data enabled an assessment of dietary quality within stores and across stores with no burden on communities and at no cost, other than time required for analysis and reporting. Similar food spending patterns and nutrient profiles were observed across the six stores. This suggests potential in using point-of-sale data to monitor and evaluate dietary quality in remote Australian communities.

  6. Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Buskirk, Caleb Griffith

    2017-06-14

    Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore,more » in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.« less

  7. Research on the range side lobe suppression method for modulated stepped frequency radar signals

    NASA Astrophysics Data System (ADS)

    Liu, Yinkai; Shan, Tao; Feng, Yuan

    2018-05-01

    The magnitude of time-domain range sidelobe of modulated stepped frequency radar affects the imaging quality of inverse synthetic aperture radar (ISAR). In this paper, the cause of high sidelobe in modulated stepped frequency radar imaging is analyzed first in real environment. Then, the chaos particle swarm optimization (CPSO) is used to select the amplitude and phase compensation factors according to the minimum sidelobe criterion. Finally, the compensated one-dimensional range images are obtained. Experimental results show that the amplitude-phase compensation method based on CPSO algorithm can effectively reduce the sidelobe peak value of one-dimensional range images, which outperforms the common sidelobe suppression methods and avoids the coverage of weak scattering points by strong scattering points due to the high sidelobes.

  8. A new method of time difference measurement: The time difference method by dual phase coincidence points detection

    NASA Technical Reports Server (NTRS)

    Zhou, Wei

    1993-01-01

    In the high accurate measurement of periodic signals, the greatest common factor frequency and its characteristics have special functions. A method of time difference measurement - the time difference method by dual 'phase coincidence points' detection is described. This method utilizes the characteristics of the greatest common factor frequency to measure time or phase difference between periodic signals. It can suit a very wide frequency range. Measurement precision and potential accuracy of several picoseconds were demonstrated with this new method. The instrument based on this method is very simple, and the demand for the common oscillator is low. This method and instrument can be used widely.

  9. LiDAR-IMU Time Delay Calibration Based on Iterative Closest Point and Iterated Sigma Point Kalman Filter

    PubMed Central

    Liu, Wanli

    2017-01-01

    The time delay calibration between Light Detection and Ranging (LiDAR) and Inertial Measurement Units (IMUs) is an essential prerequisite for its applications. However, the correspondences between LiDAR and IMU measurements are usually unknown, and thus cannot be computed directly for the time delay calibration. In order to solve the problem of LiDAR-IMU time delay calibration, this paper presents a fusion method based on iterative closest point (ICP) and iterated sigma point Kalman filter (ISPKF), which combines the advantages of ICP and ISPKF. The ICP algorithm can precisely determine the unknown transformation between LiDAR-IMU; and the ISPKF algorithm can optimally estimate the time delay calibration parameters. First of all, the coordinate transformation from the LiDAR frame to the IMU frame is realized. Second, the measurement model and time delay error model of LiDAR and IMU are established. Third, the methodology of the ICP and ISPKF procedure is presented for LiDAR-IMU time delay calibration. Experimental results are presented that validate the proposed method and demonstrate the time delay error can be accurately calibrated. PMID:28282897

  10. SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soufi, M; Arimura, H; Toyofuku, F

    Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patientmore » surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed framework might be useful for tasks involving feature-based image registration in range-image guided radiation therapy.« less

  11. Surface registration technique for close-range mapping applications

    NASA Astrophysics Data System (ADS)

    Habib, Ayman F.; Cheng, Rita W. T.

    2006-08-01

    Close-range mapping applications such as cultural heritage restoration, virtual reality modeling for the entertainment industry, and anatomical feature recognition for medical activities require 3D data that is usually acquired by high resolution close-range laser scanners. Since these datasets are typically captured from different viewpoints and/or at different times, accurate registration is a crucial procedure for 3D modeling of mapped objects. Several registration techniques are available that work directly with the raw laser points or with extracted features from the point cloud. Some examples include the commonly known Iterative Closest Point (ICP) algorithm and a recently proposed technique based on matching spin-images. This research focuses on developing a surface matching algorithm that is based on the Modified Iterated Hough Transform (MIHT) and ICP to register 3D data. The proposed algorithm works directly with the raw 3D laser points and does not assume point-to-point correspondence between two laser scans. The algorithm can simultaneously establish correspondence between two surfaces and estimates the transformation parameters relating them. Experiment with two partially overlapping laser scans of a small object is performed with the proposed algorithm and shows successful registration. A high quality of fit between the two scans is achieved and improvement is found when compared to the results obtained using the spin-image technique. The results demonstrate the feasibility of the proposed algorithm for registering 3D laser scanning data in close-range mapping applications to help with the generation of complete 3D models.

  12. Intraocular Pressure, Tear Production, and Ocular Echobiometry in Guinea Pigs (Cavia porcellus)

    PubMed Central

    Rajaei, Seyed Mehdi; Mood, Maneli Ansari; Sadjadi, Reza; Azizi, Farzaneh

    2016-01-01

    The purpose of this study was to evaluate intraocular pressure (IOP) by means of rebound tonometry, to assess tear production by using the endodontic absorbent paper point tear test (EAPTT) and phenol red thread test (PRTT), and to determine the effects of time of day on IOP and tear production in guinea pigs. The study population comprised 24 healthy adult guinea pigs (12 male, 12 female; 48 eyes) of different breeds and ranging in age from 12 to 15 mo. IOP and tear production were measured at 3 time points (0700, 1500, and 2300) during a 24-h period. Overall values (mean ± 1 SD) were: IOP, 6.81 ± 1.41 mm Hg (range, 4.83 to 8.50); PRTT, 14.33 ± 1.35 mm (range, 12.50 to 16.83); and EAPTT, 8.54 ± 1.08 mm (range, 7.17 to 10.0 mm). In addition, ultrasound biometry was performed by using a B-mode system with linear 8-MHz transducer. This study reports reference values for IOP and tear production in guinea pigs. PMID:27423156

  13. Analysis of Historical Materiel Return Program (MRP) Credits at the 1st Marine Logistics Group Reparable Issue Point (RIP)

    DTIC Science & Technology

    2011-12-01

    57 3. Description of SDNs With Lead-Times Greater Than 180 Days...58 4. Analysis of SDNs With Lead-Times Less Than 180 Days .. 61 a. Analysis of Lead-Time by SOS .................................. 63...Time ............................................. 58 Figure 24. Comparison: Percent of Total SDNs by SOS for Total Data Range vs. SDNs With Credit

  14. Infant feeding attitudes of women in the United Kingdom during pregnancy and after birth.

    PubMed

    Wilkins, Carol; Ryan, Kath; Green, Josephine; Thomas, Peter

    2012-11-01

    To address the recognized low rates of breastfeeding in the United Kingdom (UK), a change in fundamental attitudes toward infant feeding might be required. This paper reports an exploration of women's attitudes toward breastfeeding at different time points in the perinatal period, undertaken as part of a larger breastfeeding evaluation study. To measure women's infant feeding attitudes at 3 stages during the perinatal period to see whether, on average, they differed over time. Using the 17-item Iowa Infant Feeding Attitudes Scale (IIFAS), this cross-sectional study measured the infant feeding attitudes of 866 UK women at 3 perinatal stages (20 and 35 weeks antenatally and 6 weeks postpartum). Mean IIFAS scores were very similar, which shows that discrete groups of women at different time points in pregnancy and postpartum appear to have the same attitudes toward infant feeding. The predominance of scores lay in the mid-range at each of the time points, which may indicate women's indecision or ambivalent feelings about infant feeding during pregnancy and the postpartum period. Action must be undertaken to target the majority of women with mid-range scores whose ambivalence may respond positively to intervention programs. The challenge is to understand what would be appropriate and acceptable to this vulnerable group of women.

  15. On the effects of surrogacy of energy dissipation in determining the intermittency exponent in fully developed turbulence

    NASA Astrophysics Data System (ADS)

    Cleve, J.; Greiner, M.; Sreenivasan, K. R.

    2003-03-01

    The two-point correlation function of the energy dissipation, obtained from a one-point time record of an atmospheric boundary layer, reveals a rigorous power law scaling with intermittency exponent μ approx 0.20 over almost the entire inertial range of scales. However, for the related integral moment, the power law scaling is restricted to the upper part of the inertial range only. This observation is explained in terms of the operational surrogacy of the construction of energy dissipation, which influences the behaviour of the correlation function for small separation distances.

  16. Finding Out Critical Points For Real-Time Path Planning

    NASA Astrophysics Data System (ADS)

    Chen, Wei

    1989-03-01

    Path planning for a mobile robot is a classic topic, but the path planning under real-time environment is a different issue. The system sources including sampling time, processing time, processes communicating time, and memory space are very limited for this type of application. This paper presents a method which abstracts the world representation from the sensory data and makes the decision as to which point will be a potentially critical point to span the world map by using incomplete knowledge about physical world and heuristic rule. Without any previous knowledge or map of the workspace, the robot will determine the world map by roving through the workspace. The computational complexity for building and searching such a map is not more than O( n2 ) The find-path problem is well-known in robotics. Given an object with an initial location and orientation, a goal location and orientation, and a set of obstacles located in space, the problem is to find a continuous path for the object from the initial position to the goal position which avoids collisions with obstacles along the way. There are a lot of methods to find a collision-free path in given environment. Techniques for solving this problem can be classified into three approaches: 1) the configuration space approach [1],[2],[3] which represents the polygonal obstacles by vertices in a graph. The idea is to determine those parts of the free space which a reference point of the moving object can occupy without colliding with any obstacles. A path is then found for the reference point through this truly free space. Dealing with rotations turns out to be a major difficulty with the approach, requiring complex geometric algorithms which are computationally expensive. 2) the direct representation of the free space using basic shape primitives such as convex polygons [4] and overlapping generalized cones [5]. 3) the combination of technique 1 and 2 [6] by which the space is divided into the primary convex region, overlap region and obstacle region, then obstacle boundaries with attribute values are represented by the vertices of the hypergraph. The primary convex region and overlap region are represented by hyperedges, the centroids of overlap form the critical points. The difficulty is generating segment graph and estimating of minimum path width. The all techniques mentioned above need previous knowledge about the world to make path planning and the computational cost is not low. They are not available in an unknow and uncertain environment. Due to limited system resources such as CPU time, memory size and knowledge about the special application in an intelligent system (such as mobile robot), it is necessary to use algorithms that provide the good decision which is feasible with the available resources in real time rather than the best answer that could be achieved in unlimited time with unlimited resources. A real-time path planner should meet following requirements: - Quickly abstract the representation of the world from the sensory data without any previous knowledge about the robot environment. - Easily update the world model to spell out the global-path map and to reflect changes in the robot environment. - Must make a decision of where the robot must go and which direction the range sensor should point to in real time with limited resources. The method presented here assumes that the data from range sensors has been processed by signal process unite. The path planner will guide the scan of range sensor, find critical points, make decision where the robot should go and which point is poten- tial critical point, generate the path map and monitor the robot moves to the given point. The program runs recursively until the goal is reached or the whole workspace is roved through.

  17. Long-range correlations in time series generated by time-fractional diffusion: A numerical study

    NASA Astrophysics Data System (ADS)

    Barbieri, Davide; Vivoli, Alessandro

    2005-09-01

    Time series models showing power law tails in autocorrelation functions are common in econometrics. A special non-Markovian model for such kind of time series is provided by the random walk introduced by Gorenflo et al. as a discretization of time fractional diffusion. The time series so obtained are analyzed here from a numerical point of view in terms of autocorrelations and covariance matrices.

  18. Robust Airfoil Optimization to Achieve Consistent Drag Reduction Over a Mach Range

    NASA Technical Reports Server (NTRS)

    Li, Wu; Huyse, Luc; Padula, Sharon; Bushnell, Dennis M. (Technical Monitor)

    2001-01-01

    We prove mathematically that in order to avoid point-optimization at the sampled design points for multipoint airfoil optimization, the number of design points must be greater than the number of free-design variables. To overcome point-optimization at the sampled design points, a robust airfoil optimization method (called the profile optimization method) is developed and analyzed. This optimization method aims at a consistent drag reduction over a given Mach range and has three advantages: (a) it prevents severe degradation in the off-design performance by using a smart descent direction in each optimization iteration, (b) there is no random airfoil shape distortion for any iterate it generates, and (c) it allows a designer to make a trade-off between a truly optimized airfoil and the amount of computing time consumed. For illustration purposes, we use the profile optimization method to solve a lift-constrained drag minimization problem for 2-D airfoil in Euler flow with 20 free-design variables. A comparison with other airfoil optimization methods is also included.

  19. Simulators for Mariner Training and Licensing. Phase 2: Investigation of Simulator-Based Training for Maritime Cadets,

    DTIC Science & Technology

    1981-10-01

    a balance was drawn between experimental considerations (e.g., pretests and posttests ) and training process considerations (e.g., available time and...Station 23 4 Instructor’s Checkoff List 24 5 Port Approach Area 26 6 Training Unit Schedule 28 7 Pretest / Posttest Comparison: CPA - Kings Point Group A (Day...39 a Pretest / Posttest Comparison: Number of Radar Requests - Kings Point Group A (Day) 41 9 Input Characteristic Range Master Notified, Kings Point

  20. Comparison Between One-Point Calibration and Two-Point Calibration Approaches in a Continuous Glucose Monitoring Algorithm

    PubMed Central

    Mahmoudi, Zeinab; Johansen, Mette Dencker; Christiansen, Jens Sandahl

    2014-01-01

    Background: The purpose of this study was to investigate the effect of using a 1-point calibration approach instead of a 2-point calibration approach on the accuracy of a continuous glucose monitoring (CGM) algorithm. Method: A previously published real-time CGM algorithm was compared with its updated version, which used a 1-point calibration instead of a 2-point calibration. In addition, the contribution of the corrective intercept (CI) to the calibration performance was assessed. Finally, the sensor background current was estimated real-time and retrospectively. The study was performed on 132 type 1 diabetes patients. Results: Replacing the 2-point calibration with the 1-point calibration improved the CGM accuracy, with the greatest improvement achieved in hypoglycemia (18.4% median absolute relative differences [MARD] in hypoglycemia for the 2-point calibration, and 12.1% MARD in hypoglycemia for the 1-point calibration). Using 1-point calibration increased the percentage of sensor readings in zone A+B of the Clarke error grid analysis (EGA) in the full glycemic range, and also enhanced hypoglycemia sensitivity. Exclusion of CI from calibration reduced hypoglycemia accuracy, while slightly increased euglycemia accuracy. Both real-time and retrospective estimation of the sensor background current suggest that the background current can be considered zero in the calibration of the SCGM1 sensor. Conclusions: The sensor readings calibrated with the 1-point calibration approach indicated to have higher accuracy than those calibrated with the 2-point calibration approach. PMID:24876420

  1. The Trial Software version for DEMETER power spectrum files visualization and mapping

    NASA Astrophysics Data System (ADS)

    Lozbin, Anatoliy; Inchin, Alexander; Shpadi, Maxim

    2010-05-01

    In the frame of Kazakhstan's Scientific Space System creation for earthquakes precursors research, the hardware and software of DEMETER satellite was investigated. The data processing Software of DEMETER is based on package SWAN under IDL Virtual machine and realizes many features, but we can't find an important tool for the spectrograms analysis - space-time visualization of power spectrum files from electromagnetic devices as ICE and IMSC. For elimination of this problem we have developed Software which is offered to use. The DeSS (DEMETER Spectrogram Software) - it is Software for visualization, analysis and a mapping of power spectrum data from electromagnetic devices ICE and IMSC. The Software primary goal is to give the researcher friendly tool for the analysis of electromagnetic data from DEMETER Satellite for earthquake precursors and other ionosphere events researches. The Input data for DeSS Software is a power spectrum files: - Power spectrum of 1 component of the electric field in the VLF range (APID 1132); - Power spectrum of 1 component of the electric field in the HF range (APID 1134); - Power spectrum of 1 component of the magnetic field in the VLF range (APID 1137). The main features and operations of the software is possible: - various time and frequency filtration; - visualization of time dependence of signal intensity on fixed frequency; - spectral density visualization for fixed frequency range; - spectrogram autosize and smooth spectrogram; - the information in each point of the spectrogram: time, frequency and intensity; - the spectrum information in the separate window, consisting of 4 blocks; - data mapping with 6 range scale. On the map we can browse next information: - satellite orbit; - conjugate point at the satellite altitude; - north conjugate point at the altitude 110 km; - south conjugate point at the altitude 110 km. This is only trial software version to help the researchers and we always ready collaborate with scientists for software improvement. References: 1. D.Lagoutte, J.Y. Brochot, D. de Carvalho, L.Madrias and M. Parrot. DEMETER Microsatellite. Scientific Mission Center. Data product description. DMT-SP-9-CM-6054-LPC. 2. D.Lagoutte, J.Y. Brochot, P.Latremoliere. SWAN - Software for Waveform Analysis. LPCE/NI/003.E - Part 1 (User's guide), Part 2 (Analysis tools), Part 3 (User's project interface).

  2. Building a LiDAR point cloud simulator: Testing algorithms for high resolution topographic change

    NASA Astrophysics Data System (ADS)

    Carrea, Dario; Abellán, Antonio; Derron, Marc-Henri; Jaboyedoff, Michel

    2014-05-01

    Terrestrial laser technique (TLS) is becoming a common tool in Geosciences, with clear applications ranging from the generation of a high resolution 3D models to the monitoring of unstable slopes and the quantification of morphological changes. Nevertheless, like every measurement techniques, TLS still has some limitations that are not clearly understood and affect the accuracy of the dataset (point cloud). A challenge in LiDAR research is to understand the influence of instrumental parameters on measurement errors during LiDAR acquisition. Indeed, different critical parameters interact with the scans quality at different ranges: the existence of shadow areas, the spatial resolution (point density), and the diameter of the laser beam, the incidence angle and the single point accuracy. The objective of this study is to test the main limitations of different algorithms usually applied on point cloud data treatment, from alignment to monitoring. To this end, we built in MATLAB(c) environment a LiDAR point cloud simulator able to recreate the multiple sources of errors related to instrumental settings that we normally observe in real datasets. In a first step we characterized the error from single laser pulse by modelling the influence of range and incidence angle on single point data accuracy. In a second step, we simulated the scanning part of the system in order to analyze the shifting and angular error effects. Other parameters have been added to the point cloud simulator, such as point spacing, acquisition window, etc., in order to create point clouds of simple and/or complex geometries. We tested the influence of point density and vitiating point of view on the Iterative Closest Point (ICP) alignment and also in some deformation tracking algorithm with same point cloud geometry, in order to determine alignment and deformation detection threshold. We also generated a series of high resolution point clouds in order to model small changes on different environments (erosion, landslide monitoring, etc) and we then tested the use of filtering techniques using 3D moving windows along the space and time, which considerably reduces data scattering due to the benefits of data redundancy. In conclusion, the simulator allowed us to improve our different algorithms and to understand how instrumental error affects final results. And also, improve the methodology of scans acquisition to find the best compromise between point density, positioning and acquisition time with the best accuracy possible to characterize the topographic change.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strubbe, David

    Octopus is a scientific program aimed at the ab initio virtual experimentation on a hopefully ever-increasing range of system types. Electrons are described quantum-mechanically within density-functional theory (DFT), in its time-dependent form (TDDFT) when doing simulations in time. Nuclei are described classically as point particles. Electron-nucleus interaction is described within the pseudopotential approximation.

  4. Determination of the boiling-point distribution by simulated distillation from n-pentane through n-tetratetracontane in 70 to 80 seconds.

    PubMed

    Lubkowitz, Joaquin A; Meneghini, Roberto I

    2002-01-01

    This work presents the carrying out of boiling-point distributions by simulated distillation with direct-column heating rather than oven-column heating. Column-heating rates of 300 degrees C/min are obtained yielding retention times of 73 s for n-tetratetracontane. The calibration curves of the retention time versus the boiling point, in the range of n-pentane to n-tetratetracontane, are identical to those obtained by slower oven-heating rates. The boiling-point distribution of the reference gas oil is compared with that obtained with column oven heating at rates of 15 to 40 degrees C/min. The results show boiling-point distribution values nearly the same (1-2 degrees F) as those obtained with oven column heating from the initial boiling point to 80% distilled off. Slightly higher differences are obtained (3-4 degrees F) for the 80% distillation to final boiling-point interval. Nonetheless, allowed consensus differences are never exceeded. Precision of the boiling-point distributions (expressed as standard deviations) are 0.1-0.3% for the data obtained in the direct column-heating mode.

  5. Wind-influenced projectile motion

    NASA Astrophysics Data System (ADS)

    Bernardo, Reginald Christian; Perico Esguerra, Jose; Day Vallejos, Jazmine; Jerard Canda, Jeff

    2015-03-01

    We solved the wind-influenced projectile motion problem with the same initial and final heights and obtained exact analytical expressions for the shape of the trajectory, range, maximum height, time of flight, time of ascent, and time of descent with the help of the Lambert W function. It turns out that the range and maximum horizontal displacement are not always equal. When launched at a critical angle, the projectile will return to its starting position. It turns out that a launch angle of 90° maximizes the time of flight, time of ascent, time of descent, and maximum height and that the launch angle corresponding to maximum range can be obtained by solving a transcendental equation. Finally, we expressed in a parametric equation the locus of points corresponding to maximum heights for projectiles launched from the ground with the same initial speed in all directions. We used the results to estimate how much a moderate wind can modify a golf ball’s range and suggested other possible applications.

  6. Optimization of fixed-range trajectories for supersonic transport aircraft

    NASA Astrophysics Data System (ADS)

    Windhorst, Robert Dennis

    1999-11-01

    This thesis develops near-optimal guidance laws that generate minimum fuel, time, or direct operating cost fixed-range trajectories for supersonic transport aircraft. The approach uses singular perturbation techniques to time-scale de-couple the equations of motion into three sets of dynamics, two of which are analyzed in the main body of this thesis and one of which is analyzed in the Appendix. The two-point-boundary-value-problems obtained by application of the maximum principle to the dynamic systems are solved using the method of matched asymptotic expansions. Finally, the two solutions are combined using the matching principle and an additive composition rule to form a uniformly valid approximation of the full fixed-range trajectory. The approach is used on two different time-scale formulations. The first holds weight constant, and the second allows weight and range dynamics to propagate on the same time-scale. Solutions for the first formulation are only carried out to zero order in the small parameter, while solutions for the second formulation are carried out to first order. Calculations for a HSCT design were made to illustrate the method. Results show that the minimum fuel trajectory consists of three segments: a minimum fuel energy-climb, a cruise-climb, and a minimum drag glide. The minimum time trajectory also has three segments: a maximum dynamic pressure ascent, a constant altitude cruise, and a maximum dynamic pressure glide. The minimum direct operating cost trajectory is an optimal combination of the two. For realistic costs of fuel and flight time, the minimum direct operating cost trajectory is very similar to the minimum fuel trajectory. Moreover, the HSCT has three local optimum cruise speeds, with the globally optimum cruise point at the highest allowable speed, if range is sufficiently long. The final range of the trajectory determines which locally optimal speed is best. Ranges of 500 to 6,000 nautical miles, subsonic and supersonic mixed flight, and varying fuel efficiency cases are analyzed. Finally, the payload-range curve of the HSCT design is determined.

  7. The Geological Grading Scale: Every million Points Counts!

    NASA Astrophysics Data System (ADS)

    Stegman, D. R.; Cooper, C. M.

    2006-12-01

    The concept of geological time, ranging from thousands to billions of years, is naturally quite difficult for students to grasp initially, as it is much longer than the timescales over which they experience everyday life. Moreover, universities operate on a few key timescales (hourly lectures, weekly assignments, mid-term examinations) to which students' maximum attention is focused, largely driven by graded assessment. The geological grading scale exploits the overwhelming interest students have in grades as an opportunity to instill familiarity with geological time. With the geological grading scale, the number of possible points/marks/grades available in the course is scaled to 4.5 billion points --- collapsing the entirety of Earth history into one semester. Alternatively, geological time can be compressed into each assignment, with scores for weekly homeworks not worth 100 points each, but 4.5 billion! Homeworks left incomplete with questions unanswered lose 100's of millions of points - equivalent to missing the Paleozoic era. The expected quality of presentation for problem sets can be established with great impact in the first week by docking assignments an insignificant amount points for handing in messy work; though likely more points than they've lost in their entire schooling history combined. Use this grading scale and your students will gradually begin to appreciate exactly how much time represents a geological blink of the eye.

  8. Ruminal bacteria and protozoa composition, digestibility, and amino acid profile determined by multiple hydrolysis times.

    PubMed

    Fessenden, S W; Hackmann, T J; Ross, D A; Foskolos, A; Van Amburgh, M E

    2017-09-01

    Microbial samples from 4 independent experiments in lactating dairy cattle were obtained and analyzed for nutrient composition, AA digestibility, and AA profile after multiple hydrolysis times ranging from 2 to 168 h. Similar bacterial and protozoal isolation techniques were used for all isolations. Omasal bacteria and protozoa samples were analyzed for AA digestibility using a new in vitro technique. Multiple time point hydrolysis and least squares nonlinear regression were used to determine the AA content of omasal bacteria and protozoa, and equivalency comparisons were made against single time point hydrolysis. Formalin was used in 1 experiment, which negatively affected AA digestibility and likely limited the complete release of AA during acid hydrolysis. The mean AA digestibility was 87.8 and 81.6% for non-formalin-treated bacteria and protozoa, respectively. Preservation of microbe samples in formalin likely decreased recovery of several individual AA. Results from the multiple time point hydrolysis indicated that Ile, Val, and Met hydrolyzed at a slower rate compared with other essential AA. Singe time point hydrolysis was found to be nonequivalent to multiple time point hydrolysis when considering biologically important changes in estimated microbial AA profiles. Several AA, including Met, Ile, and Val, were underpredicted using AA determination after a single 24-h hydrolysis. Models for predicting postruminal supply of AA might need to consider potential bias present in postruminal AA flow literature when AA determinations are performed after single time point hydrolysis and when using formalin as a preservative for microbial samples. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Legibility Evaluation Using Point-of-regard Measurement

    NASA Astrophysics Data System (ADS)

    Saito, Daisuke; Saito, Keiichi; Saito, Masao

    Web site visibility has become important because of the rapid dissemination of World Wide Web, and combinations of foreground and background colors are crucial in providing high visibility. In our previous studies, the visibilities of several web-safe color combinations were examined using a psychological method. In those studies, simple stimuli were used because of experimental restriction. In this paper, legibility of sentences on web sites was examined using a psychophisiological method, point-of-regard measurement, to obtain other practical data. Ten people with normal color sensations ranging from ages 21 to 29 were recruited. The number of characters per line in each page was arranged in the same number, and the four representative achromatic web-safe colors, that is, #000000, #666666, #999999 and #CCCCCC, were examined. The reading time per character and the gaze time per line were obtained from point-of-regard measurement, and the normalized with the reading time and the gaze time of the three colors were calculated and compared. As the results, it was shown that the time of reading and gaze become long at the same ratio when the contrast decreases by point-of-regard measurement. Therefore, it was indicated that the legibility of color combinations could be estimated by point-of-regard measurement.

  10. Adjustable long duration high-intensity point light source

    NASA Astrophysics Data System (ADS)

    Krehl, P.; Hagelweide, J. B.

    1981-06-01

    A new long duration high-intensity point light source with adjustable light duration and a small light spot locally stable in time has been developed. The principle involved is a stationary high-temperature plasma flow inside a partly constrained capillary of a coaxial spark gap which is viewed end on through a terminating Plexiglas window. The point light spark gap is operated via a resistor by an artificial transmission line. Using two exchangeable inductance sets in the line, two ranges of photoduration 10-130 μs and 100-600 μs can be covered. For a light spot size of 1.5 mm diameter the corresponding peak light output amounts to 5×106 and 1.6×106 candelas, respectively. Within these ranges the duration is controlled by an ignitron crowbar to extinguish the plasma. The adjustable photoduration is very useful for the application of continuous writing rotating mirror cameras, thus preventing multiple exposures. The essentially uniform exposure within the visible spectral range makes the new light source suitable for color cinematography.

  11. Sloped terrain segmentation for autonomous drive using sparse 3D point cloud.

    PubMed

    Cho, Seoungjae; Kim, Jonghyun; Ikram, Warda; Cho, Kyungeun; Jeong, Young-Sik; Um, Kyhyun; Sim, Sungdae

    2014-01-01

    A ubiquitous environment for road travel that uses wireless networks requires the minimization of data exchange between vehicles. An algorithm that can segment the ground in real time is necessary to obtain location data between vehicles simultaneously executing autonomous drive. This paper proposes a framework for segmenting the ground in real time using a sparse three-dimensional (3D) point cloud acquired from undulating terrain. A sparse 3D point cloud can be acquired by scanning the geography using light detection and ranging (LiDAR) sensors. For efficient ground segmentation, 3D point clouds are quantized in units of volume pixels (voxels) and overlapping data is eliminated. We reduce nonoverlapping voxels to two dimensions by implementing a lowermost heightmap. The ground area is determined on the basis of the number of voxels in each voxel group. We execute ground segmentation in real time by proposing an approach to minimize the comparison between neighboring voxels. Furthermore, we experimentally verify that ground segmentation can be executed at about 19.31 ms per frame.

  12. Person detection and tracking with a 360° lidar system

    NASA Astrophysics Data System (ADS)

    Hammer, Marcus; Hebel, Marcus; Arens, Michael

    2017-10-01

    Today it is easily possible to generate dense point clouds of the sensor environment using 360° LiDAR (Light Detection and Ranging) sensors which are available since a number of years. The interpretation of these data is much more challenging. For the automated data evaluation the detection and classification of objects is a fundamental task. Especially in urban scenarios moving objects like persons or vehicles are of particular interest, for instance in automatic collision avoidance, for mobile sensor platforms or surveillance tasks. In literature there are several approaches for automated person detection in point clouds. While most techniques show acceptable results in object detection, the computation time is often crucial. The runtime can be problematic, especially due to the amount of data in the panoramic 360° point clouds. On the other hand, for most applications an object detection and classification in real time is needed. The paper presents a proposal for a fast, real-time capable algorithm for person detection, classification and tracking in panoramic point clouds.

  13. Nonlinear Dynamics and Nucleation Kinetics in Near-Critical Liquids

    NASA Technical Reports Server (NTRS)

    Patashinski, Alexander Z.; Ratner, Mark A.; Pines, Vladimir

    1996-01-01

    The objective of our study is to model the nonlinear behavior of a near-critical liquid following a rapid change of the temperature and/or other thermodynamic parameters (pressure, external electric or gravitational field). The thermodynamic critical point is manifested by large, strongly correlated fluctuations of the order parameter (particle density in liquid-gas systems, concentration in binary solutions) in the critical range of scales. The largest critical length scale is the correlation radius r(sub c). According to the scaling theory, r(sub c) increases as r(sub c) = r(sub 0)epsilon(exp -alpha) when the nondimensional distance epsilon = (T - T(sub c))/T(sub c) to the critical point decreases. The normal gravity alters the nature of correlated long-range fluctuations when one reaches epsilon approximately equal to 10(exp -5), and correspondingly the relaxation time, tau(r(sub c)), is approximately equal to 10(exp -3) seconds; this time is short when compared to the typical experimental time. Close to the critical point, a rapid, relatively small temperature change may perturb the thermodynamic equilibrium on many scales. The critical fluctuations have a hierarchical structure, and the relaxation involves many length and time scales. Above the critical point, in the one-phase region, we consider the relaxation of the liquid following a sudden temperature change that simultaneously violates the equilibrium on many scales. Below T(sub c), a non-equilibrium state may include a distribution of small scale phase droplets; we consider the relaxation of such a droplet following a temperature change that has made the phase of the matrix stable.

  14. Performance of the upgraded Orroral laser ranging system

    NASA Technical Reports Server (NTRS)

    Luck, John M.

    1993-01-01

    The topics discussed include the following: upgrade arrangements, system prior to 1991, elements of the upgrade, laser performance, timing system performance, pass productivity, system precision, system accuracy, telescope pointing and future upgrades and extensions.

  15. Detection of spatio-temporal change of ocean acoustic velocity for observing seafloor crustal deformation applying seismological methods

    NASA Astrophysics Data System (ADS)

    Eto, S.; Nagai, S.; Tadokoro, K.

    2011-12-01

    Our group has developed a system for observing seafloor crustal deformation with a combination of acoustic ranging and kinematic GPS positioning techniques. One of the effective factors to reduce estimation error of submarine benchmark in our system is modeling variation of ocean acoustic velocity. We estimated various 1-dimensional velocity models with depth under some constraints, because it is difficult to estimate 3-dimensional acoustic velocity structure including temporal change due to our simple acquisition procedure of acoustic ranging data. We, then, applied the joint hypocenter determination method in seismology [Kissling et al., 1994] to acoustic ranging data. We assume two conditions as constraints in inversion procedure as follows: 1) fixed acoustic velocity in deeper part because it is usually stable both in space and time, 2) each inverted velocity model should be decreased with depth. The following two remarkable spatio-temporal changes of acoustic velocity 1) variations of travel-time residuals at the same points within short time and 2) larger differences between residuals at the neighboring points, which are one's of travel-time from different benchmarks. The First results cannot be explained only by the effect of atmospheric condition change including heating by sunlight. To verify the residual variations mentioned as the second result, we have performed forward modeling of acoustic ranging data with velocity models added velocity anomalies. We calculate travel time by a pseudo-bending ray tracing method [Um and Thurber, 1987] to examine effects of velocity anomaly on the travel-time differences. Comparison between these residuals and travel-time difference in forward modeling, velocity anomaly bodies in shallower depth can make these anomalous residuals, which may indicate moving water bodies. We need to apply an acoustic velocity structure model with velocity anomaly(s) in acoustic ranging data analysis and/or to develop a new system with a large number of sea surface stations to detect them, which may be able to reduce error of seafloor benchmarker position.

  16. Efficient RPG detection in noisy 3D image data

    NASA Astrophysics Data System (ADS)

    Pipitone, Frank

    2011-06-01

    We address the automatic detection of Ambush weapons such as rocket propelled grenades (RPGs) from range data which might be derived from multiple camera stereo with textured illumination or by other means. We describe our initial work in a new project involving the efficient acquisition of 3D scene data as well as discrete point invariant techniques to perform real time search for threats to a convoy. The shapes of the jump boundaries in the scene are exploited in this paper, rather than on-surface points, due to the large error typical of depth measurement at long range and the relatively high resolution obtainable in the transverse direction. We describe examples of the generation of a novel range-scaled chain code for detecting and matching jump boundaries.

  17. Differential Detection of Enterovirus and Herpes Simplex Virus in Cerebrospinal Fluid by Real-Time RT-PCR.

    PubMed

    Sarquiz-Martínez, Brenda; González-Bonilla, César R; Santacruz-Tinoco, Clara Esperanza; Muñoz-Medina, José E; Pardavé-Alejandre, Héctor D; Barbosa-Cabrera, Elizabeth; Ramírez-González, José Ernesto; Díaz-Quiñonez, José Alberto

    2017-01-01

    Enterovirus (EV) and herpes simplex virus 1 and 2 (HSV1 and HSV2) are the main etiologic agents of central nervous system infections. Early laboratory confirmation of these infections is performed by viral culture of the cerebrospinal fluid (CSF), or the detection of specific antibodies in serum (e.g., HSV). The sensitivity of viral culture ranges from 65 to 75%, with a recovery time varying from 3 to 10 days. Serological tests are faster and easy to carry out, but they exhibit cross-reactivity between HSV1 and HSV2. Although molecular techniques are more sensitive (sensitivity >95%), they are more expensive and highly susceptible to cross-contamination. A real-time RT-PCR for the detection of EV, HSV1, and HSV2 was compared with end-point nested PCR. We tested 87 CSF samples of patients with a clinical diagnosis of viral meningitis or encephalitis. Fourteen samples were found to be positive by RT-PCR, but only 8 were positive by end-point PCR. The RT-PCR showed a specificity range of 94-100%, the negative predictive value was 100%, and the positive predictive value was 62, 100, and 28% for HSV1, HSV2, and EV, respectively. Real-time RT-PCR detected EV, HSV1, and HSV2 with a higher sensitivity and specificity than end-point nested RT-PCR. © 2017 S. Karger AG, Basel.

  18. Anatomical reconstruction for chronic lateral ankle instability in the high-demand athlete: functional outcomes after the modified Broström repair using suture anchors.

    PubMed

    Li, Xinning; Killie, Heather; Guerrero, Patrick; Busconi, Brian D

    2009-03-01

    Modification of the Bröstrom repair with suture anchors has been used to address chronic lateral ankle instability. However, there are few studies in the literature reporting the functional outcomes after this particular procedure in the high-demand athlete. Anatomical reconstruction of the lateral ankle ligaments for chronic instability will return the high-demand athlete functionally to his or her previous level of activity. Case series; Level of evidence, 4. Sixty-two patients who had grade III ankle sprain that failed at least a 6-month course of supervised conservative management with a preinjury Tegner score of > or = 6 underwent a variant of the Gould-modified Broström procedure with suture anchors for lateral ankle instability. Each patient was given the Tegner and Karlsson questionnaire at the 6-month, 1-year, and 2-year time points. Range of motion of the operative ankle was also assessed. The mean age was 19.6 years (range, 16-26 years), and 10 patients were lost to follow-up. The mean follow-up was 29 months (minimum, 24 months) in the remaining 52 patients (84%). Mean Tegner scores at the 1- and 2-year time points were 8.2 (range, 5-9) and 8.6 (range, 5-9), respectively. The mean Karlsson scores were 92 +/- 5.2 and 95 +/- 3.1 at the 1- and 2-year time points, respectively. Range of motion was equal to the contralateral ankle in all but 3 patients at the 2-year follow up. A 6% major complication rate included 3 reruptures. Anatomical ligament reconstruction for chronic lateral ankle instability using a variant of the Gould-modified Broström procedure with suture anchors was effective in returning high-demand athletes to their preinjury functional level.

  19. Time of travel of solutes in selected reaches of the Sandusky River Basin, Ohio, 1972 and 1973

    USGS Publications Warehouse

    Westfall, Arthur O.

    1976-01-01

    A time of travel study of a 106-mile (171-kilometer) reach of the Sandusky River and a 39-mile (63-kilometer) reach of Tymochtee Creek was made to determine the time required for water released from Killdeer Reservoir on Tymochtee Creek to reach selected downstream points. In general, two dye sample runs were made through each subreach to define the time-discharge relation for approximating travel times at selected discharges within the measured range, and time-discharge graphs are presented for 38 subreaches. Graphs of dye dispersion and variation in relation to time are given for three selected sampling sites. For estimating travel time and velocities between points in the study reach, tables for selected flow durations are given. Duration curves of daily discharge for four index stations are presented to indicate the lo-flow characteristics and for use in shaping downward extensions of the time-discharge curves.

  20. SKread predicts handwriting performance in patients with low vision.

    PubMed

    Downes, Ken; Walker, Laura L; Fletcher, Donald C

    2015-06-01

    To assess whether performance on the Smith-Kettlewell Reading (SKread) test is a reliable predictor of handwriting performance in patients with low vision. Cross-sectional study. Sixty-six patients at their initial low-vision rehabilitation evaluation. The patients completed all components of a routine low-vision appointment including logMAR acuity, performed the SKread test, and performed a handwriting task. Patients were timed while performing each task and their accuracy was recorded. The handwriting task was performed by having patients write 5 5-letter words into sets of boxes where each letter is separated by a box. The boxes were 15 × 15 mm, and accuracy was scored with 50 points possible from 25 letters: 1 point for each letter within the confines of a box and 1 point if the letter was legible. Correlation analysis was then performed. Median age of participants was 84 (range 54-97) years. Fifty-seven patients (86%) had age-related macular degeneration or some other maculopathy, whereas 9 patients (14%) had visual impairment from media opacity or neurologic impairment. Median Early Treatment Diabetic Retinopathy Study acuity was 20/133 (range 20/22 to 20/1000), and median logMAR acuity was 0.82 (range 0.04-1.70). SKread errors per block correlated with logMAR acuity (r = 0.6), and SKread time per block correlated with logMAR acuity (r = 0.51). SKread errors per block correlated with handwriting task time/accuracy ratio (r = 0.61). SKread time per block correlated with handwriting task time/accuracy ratio (r = 0.7). LogMAR acuity score correlated with handwriting task time/accuracy ratio (r = 0.42). All p values were < 0.01. SKread scores predict handwriting performance in patients with low vision better than logMAR acuity. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  1. On the upper part load vortex rope in Francis turbine: Experimental investigation

    NASA Astrophysics Data System (ADS)

    Nicolet, C.; Zobeiri, A.; Maruzewski, P.; Avellan, F.

    2010-08-01

    The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

  2. Real-Time Point Positioning Performance Evaluation of Single-Frequency Receivers Using NASA's Global Differential GPS System

    NASA Technical Reports Server (NTRS)

    Muellerschoen, Ronald J.; Iijima, Byron; Meyer, Robert; Bar-Sever, Yoaz; Accad, Elie

    2004-01-01

    This paper evaluates the performance of a single-frequency receiver using the 1-Hz differential corrections as provided by NASA's global differential GPS system. While the dual-frequency user has the ability to eliminate the ionosphere error by taking a linear combination of observables, the single-frequency user must remove or calibrate this error by other means. To remove the ionosphere error we take advantage of the fact that the magnitude of the group delay in range observable and the carrier phase advance have the same magnitude but are opposite in sign. A way to calibrate this error is to use a real-time database of grid points computed by JPL's RTI (Real-Time Ionosphere) software. In both cases we evaluate the positional accuracy of a kinematic carrier phase based point positioning method on a global extent.

  3. Variance change point detection for fractional Brownian motion based on the likelihood ratio test

    NASA Astrophysics Data System (ADS)

    Kucharczyk, Daniel; Wyłomańska, Agnieszka; Sikora, Grzegorz

    2018-01-01

    Fractional Brownian motion is one of the main stochastic processes used for describing the long-range dependence phenomenon for self-similar processes. It appears that for many real time series, characteristics of the data change significantly over time. Such behaviour one can observe in many applications, including physical and biological experiments. In this paper, we present a new technique for the critical change point detection for cases where the data under consideration are driven by fractional Brownian motion with a time-changed diffusion coefficient. The proposed methodology is based on the likelihood ratio approach and represents an extension of a similar methodology used for Brownian motion, the process with independent increments. Here, we also propose a statistical test for testing the significance of the estimated critical point. In addition to that, an extensive simulation study is provided to test the performance of the proposed method.

  4. Volatility of linear and nonlinear time series

    NASA Astrophysics Data System (ADS)

    Kalisky, Tomer; Ashkenazy, Yosef; Havlin, Shlomo

    2005-07-01

    Previous studies indicated that nonlinear properties of Gaussian distributed time series with long-range correlations, ui , can be detected and quantified by studying the correlations in the magnitude series ∣ui∣ , the “volatility.” However, the origin for this empirical observation still remains unclear and the exact relation between the correlations in ui and the correlations in ∣ui∣ is still unknown. Here we develop analytical relations between the scaling exponent of linear series ui and its magnitude series ∣ui∣ . Moreover, we find that nonlinear time series exhibit stronger (or the same) correlations in the magnitude time series compared with linear time series with the same two-point correlations. Based on these results we propose a simple model that generates multifractal time series by explicitly inserting long range correlations in the magnitude series; the nonlinear multifractal time series is generated by multiplying a long-range correlated time series (that represents the magnitude series) with uncorrelated time series [that represents the sign series sgn(ui) ]. We apply our techniques on daily deep ocean temperature records from the equatorial Pacific, the region of the El-Ninõ phenomenon, and find: (i) long-range correlations from several days to several years with 1/f power spectrum, (ii) significant nonlinear behavior as expressed by long-range correlations of the volatility series, and (iii) broad multifractal spectrum.

  5. Mechanisms for the clustering of inertial particles in the inertial range of isotropic turbulence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bragg, Andrew D.; Ireland, Peter J.; Collins, Lance R.

    2015-08-27

    In this study, we consider the physical mechanism for the clustering of inertial particles in the inertial range of isotropic turbulence. We analyze the exact, but unclosed, equation governing the radial distribution function (RDF) and compare the mechanisms it describes for clustering in the dissipation and inertial ranges. We demonstrate that in the limit St r <<1, where St r is the Stokes number based on the eddy turnover time scale at separation r, the clustering in the inertial range can be understood to be due to the preferential sampling of the coarse-grained fluid velocity gradient tensor at that scale.more » When St r≳O(1) this mechanism gives way to a nonlocal clustering mechanism. These findings reveal that the clustering mechanisms in the inertial range are analogous to the mechanisms that we identified for the dissipation regime. Further, we discuss the similarities and differences between the clustering mechanisms we identify in the inertial range and the “sweep-stick” mechanism developed by Coleman and Vassilicos. We show that the idea that initial particles are swept along with acceleration stagnation points is only approximately true because there always exists a finite difference between the velocity of the acceleration stagnation points and the local fluid velocity. This relative velocity is sufficient to allow particles to traverse the average distance between the stagnation points within the correlation time scale of the acceleration field. We also show that the stick part of the mechanism is only valid for St r<<1 in the inertial range. We emphasize that our clustering mechanism provides the more fundamental explanation since it, unlike the sweep-stick mechanism, is able to explain clustering in arbitrary spatially correlated velocity fields. We then consider the closed, model equation for the RDF given in Zaichik and Alipchenkov and use this, together with the results from our analysis, to predict the analytic form of the RDF in the inertial range for St r<<1, which, unlike that in the dissipation range, is not scale invariant. Finally, the results are in good agreement with direct numerical simulations, provided the separations are well within the inertial range.« less

  6. Prompt gamma timing range verification for scattered proton beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kormoll, T.; Golnik, C.; Hueso Gonzalez, F.

    2015-07-01

    Range verification is a very important point in order to fully exploit the physical advantages of protons compared to photons in cancer irradiation. Recently, a simple method has been proposed which makes use of the time of fight of protons in tissue and the promptly emitted secondary photons along the proton path (Prompt Gamma Timing, PGT). This has been considered so far for monoenergetic pencil beams only. In this work, it has been studied whether this technique can also be applied in passively formed irradiation fields with a so called spread out Bragg peak. Time correlated profiles could be recorded,more » which show a trend that is consistent with theoretical predictions. (authors)« less

  7. Treating Eyres type IV and V coracoid fracture using the acromion osteotomy approach.

    PubMed

    Wu, Jin; Fu, Xi-jin; Sha, Mo; Liu, Hui; Chen, Zhi-da; Kang, Liang-qi

    2016-02-01

    To introduce a surgical method of treating Eyres type IV and V coracoid fracture using the acromion osteotomy approach and to further analyse the clinical effectiveness of this surgical procedure. Nine patients were included in this study with a mean follow-up time of 23.3 months (range, 14.0-34.0 months). Patients were evaluated with use of the Constant score, the Simple Shoulder Test (SST) score and a visual analogue scale (VAS) pain score. Moreover, the shoulder range of motion was also observed. The mean operation time was 91.6 min with a blood loss volume ranging from 310 to 530 ml. The fractures of eight patients had recovered between 10 and 12 weeks post operation with no signs of infection, screw loosening, plate breaking or other internal fixation failures, while one case had non-union at 34 months' follow-up. The mean Constant score increased from 75.6 points preoperatively to 91.0 points at follow-up. The mean VAS score decreased from 5.3 preoperatively to 1.0 at follow-up, while the average SST score increased from 7.1 points preoperatively to 10.0 points at follow-up. The mean abduction, forward flexion, external rotation, internal rotation and backward extension angles were 162°, 159° 50°, 55° and 47°. Five cases were classified as excellent, three cases were marked as good and one case was classified as fair. Treating coracoid fracture through the approach of acromion osteotomy could be an effective treatment option with minimise damages.

  8. Hydrogenation and interesterification effects on the oxidative stability and melting point of soybean oil.

    PubMed

    Daniels, Roger L; Kim, Hyun Jung; Min, David B

    2006-08-09

    Soybean oil with an iodine value of 136 was hydrogenated to have iodine values of 126 and 117. The soybean oils with iodine values of 136, 126, and 117 were randomly interesterified using sodium methoxide. The oxidative stabilities of the hydrogenated and/or interesterified soybean oils were evaluated by measuring the headspace oxygen content by gas chromatography, and the induction time was measured using Rancimat. The melting points of the oils were evaluated by differential scanning calorimetry. Duncan's multiple range test of the headspace oxygen and induction time showed that hydrogenation increased the headspace oxygen content and induction time at alpha = 0.05. Interesterification decreased the headspace oxygen and the induction time for the soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. Hydrogenation increased the melting points as the iodine value decreased from 136 and 126 to 117 at alpha = 0.05. The random interesterification increased the melting points of soybean oils with iodine values of 136, 126, and 117 at alpha = 0.05. The combined effects of hydrogenation and interesterification increased the oxidative stability of soybean oil at alpha = 0.05 and the melting point at alpha = 0.01. The optimum combination of hydrogenation and random interesterification can improve the oxidative stability and increase the melting point to expand the application of soybean oil in foods.

  9. Study on super-resolution three-dimensional range-gated imaging technology

    NASA Astrophysics Data System (ADS)

    Guo, Huichao; Sun, Huayan; Wang, Shuai; Fan, Youchen; Li, Yuanmiao

    2018-04-01

    Range-gated three dimensional imaging technology is a hotspot in recent years, because of the advantages of high spatial resolution, high range accuracy, long range, and simultaneous reflection of target reflectivity information. Based on the study of the principle of intensity-related method, this paper has carried out theoretical analysis and experimental research. The experimental system adopts the high power pulsed semiconductor laser as light source, gated ICCD as the imaging device, can realize the imaging depth and distance flexible adjustment to achieve different work mode. The imaging experiment of small imaging depth is carried out aiming at building 500m away, and 26 group images were obtained with distance step 1.5m. In this paper, the calculation method of 3D point cloud based on triangle method is analyzed, and 15m depth slice of the target 3D point cloud are obtained by using two frame images, the distance precision is better than 0.5m. The influence of signal to noise ratio, illumination uniformity and image brightness on distance accuracy are analyzed. Based on the comparison with the time-slicing method, a method for improving the linearity of point cloud is proposed.

  10. Virtual Long Baseline (VLBL) Autonomous Underwater Vehicle Navigation Using a Single Transponder

    DTIC Science & Technology

    2006-06-01

    is needed from the lbl structure for the % indicated time range lbl_sb = sext (lbl,find(lbl.t > Start_Time & lbl.t < End_Time...Take only the lbl data points from the chosen transponder which % correspond to status 5, which means good data lbl_SB = sext (lbl_sb,find...i)); L = length(Time); % Extract the data which is needed from the state structure state_SB = sext (state,find(state.t

  11. Analysis of the low-molecular weight protein profile of egg-white and its changes during early chicken embryological development.

    PubMed

    Fang, Jun; Ma, Mei H; Qiu, Ning; Wu, Xiao; Jin, Yong G

    2012-01-01

    Many low-molecular weight (LMW) proteins in egg-white are potentially bioactive, but the mass range and number of these are not yet fully characterized. The aim of the present study was to map the LMW protein profile in egg-white and provide the basis for further understanding of the physiological function of these proteins. For this purpose, six time points (days 0, 1, 2, 3, 4, 5 of incubation) were selected in an attempt to delineate the LMW proteomic profile in egg-white and its changes during early chicken embryological development. Samples were pretreated using gel chromatography techniques prior to analysis by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS). Protein search focused on the mass range m/z 1,000 to 8,000. One hundred and fourteen mass signal peaks of LMW proteins ranging from m/z 1,035.88 to 7,112.91 were detected at all six time points. The observed changes in the LMW protein profile during development were highly dynamic. Eighty six novel mass signal peaks of LMW proteins were generated during incubation, the origin of which could be assigned to the high-molecular weight protein fractions.The list of egg-white LMW proteins provided in this paper is by far the most comprehensive and is intended to serve as a starting point for the isolation and functional characterization of interesting LMW proteins which may play a crucial role in early embryo nutrition and immunity.

  12. Acceptability of Adaptations for Struggling Writers: A National Survey with Primary-Grade Teachers

    ERIC Educational Resources Information Center

    Graham, Steve; Harris, Karen R.; Bartlett, Brendan J.; Popadopoulou, Eleni; Santoro, Julia

    2016-01-01

    One hundred twenty-five primary-grade teachers randomly selected from across the United States indicated how frequently they made 20 instructional adaptations for the struggling writers in their classroom. The measure of frequency ranged from never, several times a year, monthly, weekly, several times a week, and daily. Using a 6-point Likert-type…

  13. Fabrications, Time-Consuming Bureaucracy and Moral Dilemmas--Finnish University Employees' Experiences on the Governance of University Work

    ERIC Educational Resources Information Center

    Jauhiainen, Arto; Jauhiainen, Annukka; Laiho, Anne; Lehto, Reeta

    2015-01-01

    This article explores how the university workers of two Finnish universities experienced the range of neoliberal policymaking and governance reforms implemented in the 2000s. These reforms include quality assurance, system of defined annual working hours, outcome-based salary system and work time allocation system. Our point of view regarding…

  14. 40 CFR 463.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pH (1) (1) 1 Within the range of 6.0 to 9.0 at all times. The permit authority will obtain the... cleaning water processes at a point source times the following pollutant concentrations: Subpart B [Cleaning water] Concentration used to calculate BPT effluent limitations Pollutant or pollutant property...

  15. Spatially localized phosphorous metabolism of skeletal muscle in Duchenne muscular dystrophy patients: 24-month follow-up.

    PubMed

    Hooijmans, M T; Doorenweerd, N; Baligand, C; Verschuuren, J J G M; Ronen, I; Niks, E H; Webb, A G; Kan, H E

    2017-01-01

    To assess the changes in phosphodiester (PDE)-levels, detected by 31P magnetic resonance spectroscopy (MRS), over 24-months to determine the potential of PDE as marker for muscle tissue changes in Duchenne Muscular Dystrophy (DMD) patients. Spatially resolved phosphorous datasets were acquired in the right lower leg of 18 DMD patients (range: 5-15.4 years) and 12 age-matched healthy controls (range: 5-14 years) at three time-points (baseline, 12-months, and 24-months) using a 7T MR-System (Philips Achieva). 3-point Dixon images were acquired at 3T (Philips Ingenia) to determine muscle fat fraction. Analyses were done for six muscles that represent different stages of muscle wasting. Differences between groups and time-points were assessed with non-parametric tests with correction for multiple comparisons. Coefficient of variance (CV) were determined for PDE in four healthy adult volunteers in high and low signal-to-noise ratio (SNR) datasets. PDE-levels were significantly higher (two-fold) in DMD patients compared to controls in all analyzed muscles at almost every time point and did not change over the study period. Fat fraction was significantly elevated in all muscles at all time points compared to healthy controls, and increased significantly over time, except in the tibialis posterior muscle. The mean within subject CV for PDE-levels was 4.3% in datasets with high SNR (>10:1) and 5.7% in datasets with low SNR. The stable two-fold increase in PDE-levels found in DMD patients in muscles with different levels of muscle wasting over 2-year time, including DMD patients as young as 5.5 years-old, suggests that PDE-levels may increase very rapidly early in the disease process and remain elevated thereafter. The low CV values in high and low SNR datasets show that PDE-levels can be accurately and reproducibly quantified in all conditions. Our data confirms the great potential of PDE as a marker for muscle tissue changes in DMD patients.

  16. Spatially localized phosphorous metabolism of skeletal muscle in Duchenne muscular dystrophy patients: 24–month follow-up

    PubMed Central

    Doorenweerd, N.; Baligand, C.; Verschuuren, J. J. G. M.; Ronen, I.; Niks, E. H.; Webb, A. G.; Kan, H. E.

    2017-01-01

    Objectives To assess the changes in phosphodiester (PDE)-levels, detected by 31P magnetic resonance spectroscopy (MRS), over 24-months to determine the potential of PDE as marker for muscle tissue changes in Duchenne Muscular Dystrophy (DMD) patients. Methods Spatially resolved phosphorous datasets were acquired in the right lower leg of 18 DMD patients (range: 5–15.4 years) and 12 age-matched healthy controls (range: 5–14 years) at three time-points (baseline, 12-months, and 24-months) using a 7T MR-System (Philips Achieva). 3-point Dixon images were acquired at 3T (Philips Ingenia) to determine muscle fat fraction. Analyses were done for six muscles that represent different stages of muscle wasting. Differences between groups and time-points were assessed with non-parametric tests with correction for multiple comparisons. Coefficient of variance (CV) were determined for PDE in four healthy adult volunteers in high and low signal-to-noise ratio (SNR) datasets. Results PDE-levels were significantly higher (two-fold) in DMD patients compared to controls in all analyzed muscles at almost every time point and did not change over the study period. Fat fraction was significantly elevated in all muscles at all time points compared to healthy controls, and increased significantly over time, except in the tibialis posterior muscle. The mean within subject CV for PDE-levels was 4.3% in datasets with high SNR (>10:1) and 5.7% in datasets with low SNR. Discussion and conclusion The stable two-fold increase in PDE-levels found in DMD patients in muscles with different levels of muscle wasting over 2-year time, including DMD patients as young as 5.5 years-old, suggests that PDE-levels may increase very rapidly early in the disease process and remain elevated thereafter. The low CV values in high and low SNR datasets show that PDE-levels can be accurately and reproducibly quantified in all conditions. Our data confirms the great potential of PDE as a marker for muscle tissue changes in DMD patients. PMID:28763477

  17. The long-range correlation and evolution law of centennial-scale temperatures in Northeast China.

    PubMed

    Zheng, Xiaohui; Lian, Yi; Wang, Qiguang

    2018-01-01

    This paper applies the detrended fluctuation analysis (DFA) method to investigate the long-range correlation of monthly mean temperatures from three typical measurement stations at Harbin, Changchun, and Shenyang in Northeast China from 1909 to 2014. The results reveal the memory characteristics of the climate system in this region. By comparing the temperatures from different time periods and investigating the variations of its scaling exponents at the three stations during these different time periods, we found that the monthly mean temperature has long-range correlation, which indicates that the temperature in Northeast China has long-term memory and good predictability. The monthly time series of temperatures over the past 106 years also shows good long-range correlation characteristics. These characteristics are also obviously observed in the annual mean temperature time series. Finally, we separated the centennial-length temperature time series into two time periods. These results reveal that the long-range correlations at the Harbin station over these two time periods have large variations, whereas no obvious variations are observed at the other two stations. This indicates that warming affects the regional climate system's predictability differently at different time periods. The research results can provide a quantitative reference point for regional climate predictability assessment and future climate model evaluation.

  18. [Study of Determination of Oil Mixture Components Content Based on Quasi-Monte Carlo Method].

    PubMed

    Wang, Yu-tian; Xu, Jing; Liu, Xiao-fei; Chen, Meng-han; Wang, Shi-tao

    2015-05-01

    Gasoline, kerosene, diesel is processed by crude oil with different distillation range. The boiling range of gasoline is 35 ~205 °C. The boiling range of kerosene is 140~250 °C. And the boiling range of diesel is 180~370 °C. At the same time, the carbon chain length of differentmineral oil is different. The carbon chain-length of gasoline is within the scope of C7 to C11. The carbon chain length of kerosene is within the scope of C12 to C15. And the carbon chain length of diesel is within the scope of C15 to C18. The recognition and quantitative measurement of three kinds of mineral oil is based on different fluorescence spectrum formed in their different carbon number distribution characteristics. Mineral oil pollution occurs frequently, so monitoring mineral oil content in the ocean is very important. A new method of components content determination of spectra overlapping mineral oil mixture is proposed, with calculation of characteristic peak power integrationof three-dimensional fluorescence spectrum by using Quasi-Monte Carlo Method, combined with optimal algorithm solving optimum number of characteristic peak and range of integral region, solving nonlinear equations by using BFGS(a rank to two update method named after its inventor surname first letter, Boyden, Fletcher, Goldfarb and Shanno) method. Peak power accumulation of determined points in selected area is sensitive to small changes of fluorescence spectral line, so the measurement of small changes of component content is sensitive. At the same time, compared with the single point measurement, measurement sensitivity is improved by the decrease influence of random error due to the selection of points. Three-dimensional fluorescence spectra and fluorescence contour spectra of single mineral oil and the mixture are measured by taking kerosene, diesel and gasoline as research objects, with a single mineral oil regarded whole, not considered each mineral oil components. Six characteristic peaks are selected for characteristic peak power integration to determine components content of mineral oil mixture of gasoline, kerosene and diesel by optimal algorithm. Compared with single point measurement of peak method and mean method, measurement sensitivity is improved about 50 times. The implementation of high precision measurement of mixture components content of gasoline, kerosene and diesel provides a practical algorithm for components content direct determination of spectra overlapping mixture without chemical separation.

  19. Fusion of Building Information and Range Imaging for Autonomous Location Estimation in Indoor Environments

    PubMed Central

    Kohoutek, Tobias K.; Mautz, Rainer; Wegner, Jan D.

    2013-01-01

    We present a novel approach for autonomous location estimation and navigation in indoor environments using range images and prior scene knowledge from a GIS database (CityGML). What makes this task challenging is the arbitrary relative spatial relation between GIS and Time-of-Flight (ToF) range camera further complicated by a markerless configuration. We propose to estimate the camera's pose solely based on matching of GIS objects and their detected location in image sequences. We develop a coarse-to-fine matching strategy that is able to match point clouds without any initial parameters. Experiments with a state-of-the-art ToF point cloud show that our proposed method delivers an absolute camera position with decimeter accuracy, which is sufficient for many real-world applications (e.g., collision avoidance). PMID:23435055

  20. Coastal geology and recent origins for Sand Point, Lake Superior

    USGS Publications Warehouse

    Fisher, Timothy G.; Krantz, David E.; Castaneda, Mario R.; Loope, Walter L.; Jol, Harry M.; Goble, Ronald J.; Higley, Melinda C.; DeWald, Samantha; Hansen, Paul

    2014-01-01

    Sand Point is a small cuspate foreland located along the southeastern shore of Lake Superior within Pictured Rocks National Lakeshore near Munising, Michigan. Park managers’ concerns for the integrity of historic buildings at the northern periphery of the point during the rising lake levels in the mid-1980s greatly elevated the priority of research into the geomorphic history and age of Sand Point. To pursue this priority, we recovered sediment cores from four ponds on Sand Point, assessed subsurface stratigraphy onshore and offshore using geophysical techniques, and interpreted the chronology of events using radiocarbon and luminescence dating. Sand Point formed at the southwest edge of a subaqueous platform whose base is probably constructed of glacial diamicton and outwash. During the post-glacial Nipissing Transgression, the base was mantled with sand derived from erosion of adjacent sandstone cliffs. An aerial photograph time sequence, 1939–present, shows that the periphery of the platform has evolved considerably during historical time, infl uenced by transport of sediment into adjacent South Bay. Shallow seismic refl ections suggest slump blocks along the leading edge of the platform. Light detection and ranging (LiDAR) and shallow seismic refl ections to the northwest of the platform reveal large sand waves within a deep (12 m) channel produced by currents fl owing episodically to the northeast into Lake Superior. Ground-penetrating radar profi les show transport and deposition of sand across the upper surface of the platform. Basal radiocarbon dates from ponds between subaerial beach ridges range in age from 540 to 910 cal yr B.P., suggesting that Sand Point became emergent during the last ~1000 years, upon the separation of Lake Superior from Lakes Huron and Michigan. However, optically stimulated luminescence (OSL) ages from the beach ridges were two to three times as old as the radiocarbon ages, implying that emergence of Sand Point may have begun earlier, ~2000 years ago. The age discrepancy appears to be the result of incomplete bleaching of the quartz grains and an exceptionally low paleodose rate for the OSL samples. Given the available data, the younger ages from the radiocarbon analyses are preferred, but further work is necessary to test the two age models.

  1. Sensing Atomic Motion from the Zero Point to Room Temperature with Ultrafast Atom Interferometry.

    PubMed

    Johnson, K G; Neyenhuis, B; Mizrahi, J; Wong-Campos, J D; Monroe, C

    2015-11-20

    We sense the motion of a trapped atomic ion using a sequence of state-dependent ultrafast momentum kicks. We use this atom interferometer to characterize a nearly pure quantum state with n=1 phonon and accurately measure thermal states ranging from near the zero-point energy to n[over ¯]~10^{4}, with the possibility of extending at least 100 times higher in energy. The complete energy range of this method spans from the ground state to far outside of the Lamb-Dicke regime, where atomic motion is greater than the optical wavelength. Apart from thermometry, these interferometric techniques are useful for characterizing ultrafast entangling gates between multiple trapped ions.

  2. LSI-based amperometric sensor for bio-imaging and multi-point biosensing.

    PubMed

    Inoue, Kumi Y; Matsudaira, Masahki; Kubo, Reyushi; Nakano, Masanori; Yoshida, Shinya; Matsuzaki, Sakae; Suda, Atsushi; Kunikata, Ryota; Kimura, Tatsuo; Tsurumi, Ryota; Shioya, Toshihito; Ino, Kosuke; Shiku, Hitoshi; Satoh, Shiro; Esashi, Masayoshi; Matsue, Tomokazu

    2012-09-21

    We have developed an LSI-based amperometric sensor called "Bio-LSI" with 400 measurement points as a platform for electrochemical bio-imaging and multi-point biosensing. The system is comprised of a 10.4 mm × 10.4 mm CMOS sensor chip with 20 × 20 unit cells, an external circuit box, a control unit for data acquisition, and a DC power box. Each unit cell of the chip contains an operational amplifier with a switched-capacitor type I-V converter for in-pixel signal amplification. We successfully realized a wide dynamic range from ±1 pA to ±100 nA with a well-organized circuit design and operating software. In particular, in-pixel signal amplification and an original program to control the signal read-out contribute to the lower detection limit and wide detection range of Bio-LSI. The spacial resolution is 250 μm and the temporal resolution is 18-125 ms/400 points, which depends on the desired current detection range. The coefficient of variance of the current for 400 points is within 5%. We also demonstrated the real-time imaging of a biological molecule using Bio-LSI. The LSI coated with an Os-HRP film was successfully applied to the monitoring of the changes of hydrogen peroxide concentration in a flow. The Os-HRP-coated LSI was spotted with glucose oxidase and used for bioelectrochemical imaging of the glucose oxidase (GOx)-catalyzed oxidation of glucose. Bio-LSI is a promising platform for a wide range of analytical fields, including diagnostics, environmental measurements and basic biochemistry.

  3. Evaluation of Salmonella movement through the gut of the lesser mealworm, Alphitobius diaperinus (Coleoptera: Tenebrionidae).

    PubMed

    Zheng, Longyu; Crippen, Tawni L; Sheffield, Cynthia L; Poole, Toni L; Yu, Ziniu; Tomberlin, Jeffrey K

    2012-04-01

    The lesser mealworm, Alphitobius diaperinus is an important poultry pest prevalent during production that is capable of vectoring pathogens. This study was undertaken to determine the gut transit time of Salmonella for biosecurity risk analysis of pathogen dispersal into the environment. Adult and larval A. diaperinus were exposed to two concentrations of a fluorescently labeled Salmonella enterica for 15, 30, and 60 min time periods then externally disinfected to evaluate internal transfer of Salmonella. The insects were monitored every 30 min over 4 h and evacuated frass (feces) processed for the marker Salmonella. The minimum time monitored was 45 min (15 exposure+30 min time point), and the maximum was 5 h (60 exposure+4 h time point). Adults treated with 10(6) or 10(8) colony-forming units (cfu)/mL, which produced Salmonella positive frass within the 5 h experimental time, displayed a mean gut transit time of 144.4 min (range 90-270 min) and 186.3 min (range 120-300 min), respectively. Larvae treated with 10(6) or 10(8) cfu/mL displayed a mean gut transit time of 172.5 min (range 120-300 min) and 131.7 min (range 60-300 min), respectively. Understanding the sources and contribution of reservoir populations of pathogens in poultry production operations is important for development of biosecurity measures to mitigate their transfer. A. diaperinus are prevalent in production operations and difficult to suppress. Management standards accept the reutilization of litter in which insects survive between flock rotations. Removing litter and spreading it onto nearby fields results in the inadvertent dispersal of beetles. Few studies demonstrating the specific bacterial dispersal capacities of these insects have been performed. This study determined that Salmonella acquired internally, commonly transits the gut, allowed the insect to disperse viable pathogenic bacteria within 2-3 h.

  4. Validation of a virtual reality-based simulator for shoulder arthroscopy.

    PubMed

    Rahm, Stefan; Germann, Marco; Hingsammer, Andreas; Wieser, Karl; Gerber, Christian

    2016-05-01

    This study was to determine face and construct validity of a new virtual reality-based shoulder arthroscopy simulator which uses passive haptic feedback. Fifty-one participants including 25 novices (<20 shoulder arthroscopies) and 26 experts (>100 shoulder arthroscopies) completed two tests: for assessment of face validity, a questionnaire was filled out concerning quality of simulated reality and training potential using a 7-point Likert scale (range 1-7). Construct validity was tested by comparing simulator metrics (operation time in seconds, camera and grasper pathway in centimetre and grasper openings) between novices and experts test results. Overall simulated reality was rated high with a median value of 5.5 (range 2.8-7) points. Training capacity scored a median value of 5.8 (range 3-7) points. Experts were significantly faster in the diagnostic test with a median of 91 (range 37-208) s than novices with 1177 (range 81-383) s (p < 0.0001) and in the therapeutic test 102 (range 58-283) s versus 229 (range 114-399) s (p < 0.0001). Similar results were seen in the other metric values except in the camera pathway in the therapeutic test. The tested simulator achieved high scores in terms of realism and training capability. It reliably discriminated between novices and experts. Further improvements of the simulator, especially in the field of therapeutic arthroscopy, might improve its value as training and assessment tool for shoulder arthroscopy skills. II.

  5. Application of Time-Frequency Representations To Non-Stationary Radar Cross Section

    DTIC Science & Technology

    2009-03-01

    The three- dimensional plot produced by a TFR allows one to determine which spectral components of a signal vary with time [25... a range bin ( of width cT 2 ) from the stepped frequency waveform. 2. Cancel the clutter (stationary components) by zeroing out points associated with ...generating an infinite number of bilinear Time Frequency distributions based on a generalized equation and a change- able

  6. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    PubMed

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P < .01). The mean physical component of the SF-12 score significantly improved, from 25.69 points preoperatively (range, 6-39) to 54.62 at final follow-up (range, 32-62; P < .01). The mean mental component of the SF-12 score also significantly improved, from 28.20 points preoperatively (range, 14-45) to 58.41 at final follow-up (range, 36-67; P < .01). The mean time to fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  7. Scaling Analysis of Tide Gauge Data from the Atlantic, Gulf of Mexico, and Pacific Coasts of the United States

    NASA Astrophysics Data System (ADS)

    Barton, C. C.; Smigelski, J. R.; Tebbens, S. F.

    2008-12-01

    Most coastal regions are subject to inundation due to many periodic and non-periodic inputs including for example: diurnal and semi diurnal tides, storms, tsunamis, and global sea level change. Tide guage data provide a frequently sampled long term record of fluctuations in water level. A power-spectral-density analysis of tidal gauge data is used to quantify persistence (degree of internal correlation over various time intervals) in terms of the scaling exponent β and to identify temporal changes in persistence. The stations are located at different proximity to the open ocean, including bays, harbors, and channels. The datasets are from the NOAA CO-OPS Verified Hourly Station Datum. The length of the data sets ranges from 3 years to 101 years. The hourly data sets are decimated to one record every four hours. All data sets analyzed show three distinct regions of persistence with two inflection points at approximately one day and five days. For times less than one day, the scaling exponent ranges between 0 < β < 2.6. For the time interval 1 to 5 days, the scaling exponent ranges between 1.1 < β < 2.1. For times greater than 5 days, the scaling exponent ranges between 0.4 < β < 0.9. Persistence generally decreases as period increases but is stable between the inflection points. At Duck, NC, long term persistence in the tide gauge signal is 0.6 as compared to 0.9 for the biweekly shoreline position signal over twenty years, suggesting a strong correlation between the two and the possibility of using tide gauge data to quantify nearby shoreline mobility over similar time intervals.

  8. TWENTY-FIVE SUBARCSECOND BINARIES DISCOVERED BY LUNAR OCCULTATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richichi, A.; Fors, O.; Cusano, F.

    2013-09-15

    We report on 25 subarcsecond binaries, detected for the first time by means of lunar occultations in the near-infrared (near-IR) as part of a long-term program using the ISAAC instrument at the ESO Very Large Telescope. The primaries have magnitudes in the range K = 3.8-10.4, and the companions in the range K = 6.4-12.1. The magnitude differences have a median value of 2.8, with the largest being 5.4. The projected separations are in the range 6-748 mas and with a median of 18 mas, or about three times less than the diffraction limit of the telescope. Among our binarymore » detections are a pre-main-sequence star and an enigmatic Mira-like variable previously suspected to have a companion. Additionally, we quote an accurate first-time near-IR detection of a previously known wider binary. We discuss our findings on an individual basis as far as made possible by the available literature, and we examine them from a statistical point of view. We derive a typical frequency of binarity among field stars of Almost-Equal-To 10%, in the resolution and sensitivity range afforded by the technique ( Almost-Equal-To 0.''003 to Almost-Equal-To 0.''5, and K Almost-Equal-To 12 mag, respectively). This is in line with previous results using the same technique but we point out interesting differences that we can trace up to sensitivity, time sampling, and average distance of the targets. Finally, we discuss the prospects for further follow-up studies.« less

  9. Stratifying the risks of oral anticoagulation in patients with liver disease.

    PubMed

    Efird, Lydia M; Mishkin, Daniel S; Berlowitz, Dan R; Ash, Arlene S; Hylek, Elaine M; Ozonoff, Al; Reisman, Joel I; Zhao, Shibei; Jasuja, Guneet K; Rose, Adam J

    2014-05-01

    Chronic liver disease presents a relative contraindication to warfarin therapy, but some patients with liver disease nevertheless require long-term anticoagulation. The goal is to identify which patients with liver disease might safely receive warfarin. Among 102 134 patients who received warfarin from the Veterans Affairs from 2007 to 2008, International Classification of Diseases-Ninth Revision codes identified 1763 patients with chronic liver disease. Specific diagnoses and laboratory values (albumin, aspartate aminotransferase, alanine aminotransferase, creatinine, and cholesterol) were examined to identify risk of adverse outcomes, while controlling for available bleeding risk factors. Outcomes included percent time in therapeutic range, a measure of anticoagulation control, and major hemorrhagic events, by International Classification of Diseases-Ninth Revision codes. Patients with liver disease had lower mean time in therapeutic range (53.5%) when compared with patients without (61.7%; P<0.001) and more hemorrhages (hazard ratio, 2.02; P<0.001). Among patients with liver disease, serum albumin and creatinine levels were the strongest predictors of both outcomes. We created a 4-point score system: patients received 1 point each for albumin (2.5-3.49 g/dL) or creatinine (1.01-1.99 mg/dL), and 2 points each for albumin (<2.5 g/dL) or creatinine (≥2 mg/dL). This score predicted both anticoagulation control and hemorrhage. When compared with patients without liver disease, those with a score of zero had modestly lower time in therapeutic range (56.7%) and no increase in hemorrhages (hazard ratio, 1.16; P=0.59), whereas those with the worst score (4) had poor control (29.4%) and high hazard of hemorrhage (hazard ratio, 8.53; P<0.001). Patients with liver disease receiving warfarin have poorer anticoagulation control and more hemorrhages. A simple 4-point scoring system using albumin and creatinine identifies those at risk for poor outcomes. © 2014 American Heart Association, Inc.

  10. Sloped Terrain Segmentation for Autonomous Drive Using Sparse 3D Point Cloud

    PubMed Central

    Cho, Seoungjae; Kim, Jonghyun; Ikram, Warda; Cho, Kyungeun; Sim, Sungdae

    2014-01-01

    A ubiquitous environment for road travel that uses wireless networks requires the minimization of data exchange between vehicles. An algorithm that can segment the ground in real time is necessary to obtain location data between vehicles simultaneously executing autonomous drive. This paper proposes a framework for segmenting the ground in real time using a sparse three-dimensional (3D) point cloud acquired from undulating terrain. A sparse 3D point cloud can be acquired by scanning the geography using light detection and ranging (LiDAR) sensors. For efficient ground segmentation, 3D point clouds are quantized in units of volume pixels (voxels) and overlapping data is eliminated. We reduce nonoverlapping voxels to two dimensions by implementing a lowermost heightmap. The ground area is determined on the basis of the number of voxels in each voxel group. We execute ground segmentation in real time by proposing an approach to minimize the comparison between neighboring voxels. Furthermore, we experimentally verify that ground segmentation can be executed at about 19.31 ms per frame. PMID:25093204

  11. Influence of the Cavity Length on the Behavior of Hybrid Fixed-Point Cells Constructed at INRIM

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Girard, F.; Florio, M.

    2015-03-01

    Hybrid cells with double carbon/carbon sheets are used at the Istituto Nazionale di Ricerca Metrologica (INRIM) for the realization of both pure metal fixed points and high-temperature metal-carbon eutectic points. Cells for the Cu and Co-C fixed points have been prepared to be used in the high-temperature fixed-point project of the Comité Consultatif de Thermométrie. The results of the evaluation processes were not completely satisfactory for the INRIM cells because of their low transition temperatures with respect to the best cells, and of a rather large melting range for the Co-C cell. A new design of the cells was devised, and considerable improvements were achieved with respect to the transition temperature, and the plateau shape and duration. As for the Cu point, the duration of the freezing plateaux increased by more than 50 % and the freezing temperature increased by 18 mK. As for the Co-C point, the melting temperature, expressed in terms of the point of inflection of the melting curve, increased by about 70 mK. The melting range of the plateaux, expressed as a difference was reduced from about 180 mK to about 130 mK, with melting times increased by about 50 %, as a consequence of an improvement of flatness and run-off of the plateaux.

  12. Indicator saturation: a novel approach to detect multiple breaks in geodetic time series.

    NASA Astrophysics Data System (ADS)

    Jackson, L. P.; Pretis, F.; Williams, S. D. P.

    2016-12-01

    Geodetic time series can record long term trends, quasi-periodic signals at a variety of time scales from days to decades, and sudden breaks due to natural or anthropogenic causes. The causes of breaks range from instrument replacement to earthquakes to unknown (i.e. no attributable cause). Furthermore, breaks can be permanent or short-lived and range at least two orders of magnitude in size (mm to 100's mm). To account for this range of possible signal-characteristics requires a flexible time series method that can distinguish between true and false breaks, outliers and time-varying trends. One such method, Indicator Saturation (IS) comes from the field of econometrics where analysing stochastic signals in these terms is a common problem. The IS approach differs from alternative break detection methods by considering every point in the time series as a break until it is demonstrated statistically that it is not. A linear model is constructed with a break function at every point in time, and all but statistically significant breaks are removed through a general-to-specific model selection algorithm for more variables than observations. The IS method is flexible because it allows multiple breaks of different forms (e.g. impulses, shifts in the mean, and changing trends) to be detected, while simultaneously modelling any underlying variation driven by additional covariates. We apply the IS method to identify breaks in a suite of synthetic GPS time series used for the Detection of Offsets in GPS Experiments (DOGEX). We optimise the method to maximise the ratio of true-positive to false-positive detections, which improves estimates of errors in the long term rates of land motion currently required by the GPS community.

  13. Assessing the Transient Gust Response of a Representative Ship Airwake using Proper Orthogonal Decomposition

    DTIC Science & Technology

    Velocimetry system was then used to acquire flow field data across a series of three horizontal planes spanning from 0.25 to 1.5 times the ship hangar height...included six separate data points at gust-frequency referenced Strouhal numbers ranging from 0.430 to1.474. A 725-Hertz time -resolved Particle Image

  14. 40 CFR 463.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... TSS 117 36 pH (1) (1) 1 Within the range of 6.0 to 9.0 at all times. The permit authority will obtain... for the cleaning water processes at a point source times the following pollutant concentrations: Subpart B [Cleaning water] Concentration used to calculate BPT effluent limitations Pollutant or pollutant...

  15. 40 CFR 463.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... TSS 117 36 pH (1) (1) 1 Within the range of 6.0 to 9.0 at all times. The permit authority will obtain... for the cleaning water processes at a point source times the following pollutant concentrations: Subpart B [Cleaning water] Concentration used to calculate BPT effluent limitations Pollutant or pollutant...

  16. 40 CFR 463.22 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... TSS 117 36 pH (1) (1) 1 Within the range of 6.0 to 9.0 at all times. The permit authority will obtain... for the cleaning water processes at a point source times the following pollutant concentrations: Subpart B [Cleaning water] Concentration used to calculate BPT effluent limitations Pollutant or pollutant...

  17. Longitudinal employment outcomes of an early intervention vocational rehabilitation service for people admitted to rehabilitation with a traumatic spinal cord injury.

    PubMed

    Hilton, G; Unsworth, C A; Murphy, G C; Browne, M; Olver, J

    2017-08-01

    Longitudinal cohort design. First, to explore the longitudinal outcomes for people who received early intervention vocational rehabilitation (EIVR); second, to examine the nature and extent of relationships between contextual factors and employment outcomes over time. Both inpatient and community-based clients of a Spinal Community Integration Service (SCIS). People of workforce age undergoing inpatient rehabilitation for traumatic spinal cord injury were invited to participate in EIVR as part of SCIS. Data were collected at the following three time points: discharge and at 1 year and 2+ years post discharge. Measures included the spinal cord independence measure, hospital anxiety and depression scale, impact on participation and autonomy scale, numerical pain-rating scale and personal wellbeing index. A range of chi square, correlation and regression tests were undertaken to look for relationships between employment outcomes and demographic, emotional and physical characteristics. Ninety-seven participants were recruited and 60 were available at the final time point where 33% (95% confidence interval (CI): 24-42%) had achieved an employment outcome. Greater social participation was strongly correlated with wellbeing (ρ=0.692), and reduced anxiety (ρ=-0.522), depression (ρ=-0.643) and pain (ρ=-0.427) at the final time point. In a generalised linear mixed effect model, education status, relationship status and subjective wellbeing increased significantly the odds of being employed at the final time point. Tertiary education prior to injury was associated with eight times increased odds of being in employment at the final time point; being in a relationship at the time of injury was associated with increased odds of being in employment of more than 3.5; subjective wellbeing, while being the least powerful predictor was still associated with increased odds (1.8 times) of being employed at the final time point. EIVR shows promise in delivering similar return-to-work rates as those traditionally reported, but sooner. The dynamics around relationships, subjective wellbeing, social participation and employment outcomes require further exploration.

  18. Statistical symmetry restoration in fully developed turbulence: Renormalization group analysis of two models.

    PubMed

    Antonov, N V; Gulitskiy, N M; Kostenko, M M; Malyshev, A V

    2018-03-01

    In this paper we consider the model of incompressible fluid described by the stochastic Navier-Stokes equation with finite correlation time of a random force. Inertial-range asymptotic behavior of fully developed turbulence is studied by means of the field theoretic renormalization group within the one-loop approximation. It is corroborated that regardless of the values of model parameters and initial data the inertial-range behavior of the model is described by the limiting case of vanishing correlation time. This indicates that the Galilean symmetry of the model violated by the "colored" random force is restored in the inertial range. This regime corresponds to the only nontrivial fixed point of the renormalization group equation. The stability of this point depends on the relation between the exponents in the energy spectrum E∝k^{1-y} and the dispersion law ω∝k^{2-η}. The second analyzed problem is the passive advection of a scalar field by this velocity ensemble. Correlation functions of the scalar field exhibit anomalous scaling behavior in the inertial-convective range. We demonstrate that in accordance with Kolmogorov's hypothesis of the local symmetry restoration the main contribution to the operator product expansion is given by the isotropic operator, while anisotropic terms should be considered only as corrections.

  19. Statistical symmetry restoration in fully developed turbulence: Renormalization group analysis of two models

    NASA Astrophysics Data System (ADS)

    Antonov, N. V.; Gulitskiy, N. M.; Kostenko, M. M.; Malyshev, A. V.

    2018-03-01

    In this paper we consider the model of incompressible fluid described by the stochastic Navier-Stokes equation with finite correlation time of a random force. Inertial-range asymptotic behavior of fully developed turbulence is studied by means of the field theoretic renormalization group within the one-loop approximation. It is corroborated that regardless of the values of model parameters and initial data the inertial-range behavior of the model is described by the limiting case of vanishing correlation time. This indicates that the Galilean symmetry of the model violated by the "colored" random force is restored in the inertial range. This regime corresponds to the only nontrivial fixed point of the renormalization group equation. The stability of this point depends on the relation between the exponents in the energy spectrum E ∝k1 -y and the dispersion law ω ∝k2 -η . The second analyzed problem is the passive advection of a scalar field by this velocity ensemble. Correlation functions of the scalar field exhibit anomalous scaling behavior in the inertial-convective range. We demonstrate that in accordance with Kolmogorov's hypothesis of the local symmetry restoration the main contribution to the operator product expansion is given by the isotropic operator, while anisotropic terms should be considered only as corrections.

  20. Acute Toxicity Evaluation of Nitroaromatic Compounds

    DTIC Science & Technology

    1991-03-01

    eye of any animal during the observation period. Extreme fluorescein staining was evident in all of the test animals. Pannus (corneal vasculation) was...treated eyes at this time point showed signs of pannus . 39 0 TABLE 13 ACUTE ORAL - RANGE FINDING - RATS 1,3,5-TRINITROBENZENE Dose Dose Wt (g) Wt (g) Wt...the cornea at the 24h, 48h, 72h and 96h observation points. Additional Observations: Pannus (corneal vascularization) was noted at the 96h observation

  1. Improved nutrition in adolescents and young adults after childhood cancer - INAYA study.

    PubMed

    Quidde, J; von Grundherr, J; Koch, B; Bokemeyer, C; Escherich, G; Valentini, L; Buchholz, D; Schilling, G; Stein, A

    2016-11-08

    Multimodality treatment improves the chance of survival but increases the risk for long-term side effects in young cancer survivors, so-called" Adolescents and Young Adults"(AYAs). Compared to the general population AYAs have a 5 to 15-fold increased risk of cardiovascular morbidity. Thus, improving modifiable lifestyle risk factors is of particular importance. The INAYA trial included AYAs between 18 and 39 years receiving an intensified individual nutrition counseling at four time points in a 3-month period based on a 3-day dietary record. At week 0 and 12 AYAs got a face-to-face counseling, at week 2 and 6 by telephone. Primary endpoint was change in nutritional behavior measured by Healthy Eating Index - European Prospective Investigation into Cancer and Nutrition (HEI-EPIC). Twenty-three AYAs (11 female, 12 male, median age 20 years (range 19-23 years), median BMI: 21.4 kg/m 2 (range: 19.7-23.9 kg/m 2 ) after completion of cancer treatment for sarcoma (n = 2), carcinoma (n = 2), blastoma (n = 1), hodgkin lymphoma (n = 12), or leukemia (n = 6) were included (median time between diagnosis and study inclusion was 44 month). The primary endpoint was met, with an improvement of 20 points in HEI-EPIC score in 52.2 % (n = 12) of AYAs. At baseline, median HEI-EPIC score was 47.0 points (range from 40.0 to 55.0 points) and a good, moderate and bad nutritional intake was seen in 4.3, 73.9 and 21.7 % of AYAs. At week 12, median HEI-EPIC improved significantly to 65.0 points (range from 55.0 to 76.0 points) (p ≤ 0.001) and a good, moderate and bad nutritional intake was seen in 47.8, 52.2 and 0 % of AYAs. No change was seen in quality of life, waist-hip ratio and blood pressure. Intensified nutrition counseling is feasible and seem to improve nutritional behavior of AYAs. Further studies will be required to demonstrate long-term sustainability and confirm the results in a randomized design in larger cohorts. Clinical trial identifier DRKS00009883 on DRKS.

  2. Real-time determination of the worst tsunami scenario based on Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Furuya, Takashi; Koshimura, Shunichi; Hino, Ryota; Ohta, Yusaku; Inoue, Takuya

    2016-04-01

    In recent years, real-time tsunami inundation forecasting has been developed with the advances of dense seismic monitoring, GPS Earth observation, offshore tsunami observation networks, and high-performance computing infrastructure (Koshimura et al., 2014). Several uncertainties are involved in tsunami inundation modeling and it is believed that tsunami generation model is one of the great uncertain sources. Uncertain tsunami source model has risk to underestimate tsunami height, extent of inundation zone, and damage. Tsunami source inversion using observed seismic, geodetic and tsunami data is the most effective to avoid underestimation of tsunami, but needs to expect more time to acquire the observed data and this limitation makes difficult to terminate real-time tsunami inundation forecasting within sufficient time. Not waiting for the precise tsunami observation information, but from disaster management point of view, we aim to determine the worst tsunami source scenario, for the use of real-time tsunami inundation forecasting and mapping, using the seismic information of Earthquake Early Warning (EEW) that can be obtained immediately after the event triggered. After an earthquake occurs, JMA's EEW estimates magnitude and hypocenter. With the constraints of earthquake magnitude, hypocenter and scaling law, we determine possible multi tsunami source scenarios and start searching the worst one by the superposition of pre-computed tsunami Green's functions, i.e. time series of tsunami height at offshore points corresponding to 2-dimensional Gaussian unit source, e.g. Tsushima et al., 2014. Scenario analysis of our method consists of following 2 steps. (1) Searching the worst scenario range by calculating 90 scenarios with various strike and fault-position. From maximum tsunami height of 90 scenarios, we determine a narrower strike range which causes high tsunami height in the area of concern. (2) Calculating 900 scenarios that have different strike, dip, length, width, depth and fault-position. Note that strike is limited with the range obtained from 90 scenarios calculation. From 900 scenarios, we determine the worst tsunami scenarios from disaster management point of view, such as the one with shortest travel time and the highest water level. The method was applied to a hypothetical-earthquake, and verified if it can effectively search the worst tsunami source scenario in real-time, to be used as an input of real-time tsunami inundation forecasting.

  3. Uncalibrated stereo rectification and disparity range stabilization: a comparison of different feature detectors

    NASA Astrophysics Data System (ADS)

    Luo, Xiongbiao; Jayarathne, Uditha L.; McLeod, A. Jonathan; Pautler, Stephen E.; Schlacta, Christopher M.; Peters, Terry M.

    2016-03-01

    This paper studies uncalibrated stereo rectification and stable disparity range determination for surgical scene three-dimensional (3-D) reconstruction. Stereoscopic endoscope calibration sometimes is not available and also increases the complexity of the operating-room environment. Stereo from uncalibrated endoscopic cameras is an alternative to reconstruct the surgical field visualized by binocular endoscopes within the body. Uncalibrated rectification is usually performed on the basis of a number of matched feature points (semi-dense correspondence) between the left and the right images of stereo pairs. After uncalibrated rectification, the corresponding feature points can be used to determine the proper disparity range that helps to improve the reconstruction accuracy and reduce the computational time of disparity map estimation. Therefore, the corresponding or matching accuracy and robustness of feature point descriptors is important to surgical field 3-D reconstruction. This work compares four feature detectors: (1) scale invariant feature transform (SIFT), (2) speeded up robust features (SURF), (3) affine scale invariant feature transform (ASIFT), and (4) gauge speeded up robust features (GSURF) with applications to uncalibrated rectification and stable disparity range determination. We performed our experiments on surgical endoscopic video images that were collected during robotic prostatectomy. The experimental results demonstrate that ASIFT outperforms other feature detectors in the uncalibrated stereo rectification and also provides a stable stable disparity range for surgical scene reconstruction.

  4. Space-Time Point Pattern Analysis of Flavescence Dorée Epidemic in a Grapevine Field: Disease Progression and Recovery

    PubMed Central

    Maggi, Federico; Bosco, Domenico; Galetto, Luciana; Palmano, Sabrina; Marzachì, Cristina

    2017-01-01

    Analyses of space-time statistical features of a flavescence dorée (FD) epidemic in Vitis vinifera plants are presented. FD spread was surveyed from 2011 to 2015 in a vineyard of 17,500 m2 surface area in the Piemonte region, Italy; count and position of symptomatic plants were used to test the hypothesis of epidemic Complete Spatial Randomness and isotropicity in the space-time static (year-by-year) point pattern measure. Space-time dynamic (year-to-year) point pattern analyses were applied to newly infected and recovered plants to highlight statistics of FD progression and regression over time. Results highlighted point patterns ranging from disperse (at small scales) to aggregated (at large scales) over the years, suggesting that the FD epidemic is characterized by multiscale properties that may depend on infection incidence, vector population, and flight behavior. Dynamic analyses showed moderate preferential progression and regression along rows. Nearly uniform distributions of direction and negative exponential distributions of distance of newly symptomatic and recovered plants relative to existing symptomatic plants highlighted features of vector mobility similar to Brownian motion. These evidences indicate that space-time epidemics modeling should include environmental setting (e.g., vineyard geometry and topography) to capture anisotropicity as well as statistical features of vector flight behavior, plant recovery and susceptibility, and plant mortality. PMID:28111581

  5. Simulations of potential future conditions in the cache critical groundwater area, Arkansas

    USGS Publications Warehouse

    Rashid, Haveen M.; Clark, Brian R.; Mahdi, Hanan H.; Rifai, Hanadi S.; Al-Shukri, Haydar J.

    2015-01-01

    A three-dimensional finite-difference model for part of the Mississippi River Valley alluvial aquifer in the Cache Critical Groundwater Area of eastern Arkansas was constructed to simulate potential future conditions of groundwater flow. The objectives of this study were to test different pilot point distributions to find reasonable estimates of aquifer properties for the alluvial aquifer, to simulate flux from rivers, and to demonstrate how changes in pumping rates for different scenarios affect areas of long-term water-level declines over time. The model was calibrated using the parameter estimation code. Additional calibration was achieved using pilot points with regularization and singular value decomposition. Pilot point parameter values were estimated at a number of discrete locations in the study area to obtain reasonable estimates of aquifer properties. Nine pumping scenarios for the years 2011 to 2020 were tested and compared to the simulated water-level heads from 2010. Hydraulic conductivity values from pilot point calibration ranged between 42 and 173 m/d. Specific yield values ranged between 0.19 and 0.337. Recharge rates ranged between 0.00009 and 0.0006 m/d. The model was calibrated using 2,322 hydraulic head measurements for the years 2000 to 2010 from 150 observation wells located in the study area. For all scenarios, the volume of water depleted ranged between 5.7 and 23.3 percent, except in Scenario 2 (minimum pumping rates), in which the volume increased by 2.5 percent.

  6. Divorcing Mothers’ Use of Protective Strategies: Differences Over Time and by Violence Experience

    PubMed Central

    Haselschwerdt, Megan L.; Mitchell, Elissa Thomann; Raffaelli, Marcela; Hardesty, Jennifer L.

    2015-01-01

    Objective The current study considered protective strategy use at various points in time for divorcing mothers with a range of marital violence experiences (including no history of violence and different types of violence). Method Divorcing mothers (N = 170) from one Midwestern county participated in two in-person interviews that included structured assessments of intimate partner violence (IPV) during the last year of marriage and use of protective strategies at three time points – last year of marriage and at separation (both assessed at Time 1) and since the first interview (at a three month follow-up). Results Divorcing mothers, regardless of marital violence experience, used an array of private and public protective strategies during the last year of marriage, at separation, and at the three-month follow up interview. In general, mothers who experienced coercive controlling violence reported using more protective strategies than mothers who experienced situational couple violence or no violence. Strategy use peaked at separation with an increase in public strategy use. Conclusions All divorcing mothers use a range of active coping strategies over time, yet findings emphasize the importance of making distinctions between types of IPV so that divorcing mothers receive individualized resources and support that best meet their needs and minimize potentials risks and losses as they navigate the divorce process. PMID:26858851

  7. A 3D photographic capsule endoscope system with full field of view

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Lai, Chien-Cheng; Kung, Yi-Chinn; Tao, Kuan-Heng

    2013-09-01

    Current capsule endoscope uses one camera to capture the surface image in the intestine. It can only observe the abnormal point, but cannot know the exact information of this abnormal point. Using two cameras can generate 3D images, but the visual plane changes while capsule endoscope rotates. It causes that two cameras can't capture the images information completely. To solve this question, this research provides a new kind of capsule endoscope to capture 3D images, which is 'A 3D photographic capsule endoscope system'. The system uses three cameras to capture images in real time. The advantage is increasing the viewing range up to 2.99 times respect to the two camera system. The system can accompany 3D monitor provides the exact information of symptom points, helping doctors diagnose the disease.

  8. Optical timing receiver for the NASA laser ranging system. Part 2: High precision time interval digitizer

    NASA Technical Reports Server (NTRS)

    Leskovar, B.; Turko, B.

    1977-01-01

    The development of a high precision time interval digitizer is described. The time digitizer is a 10 psec resolution stop watch covering a range of up to 340 msec. The measured time interval is determined as a separation between leading edges of a pair of pulses applied externally to the start input and the stop input of the digitizer. Employing an interpolation techniques and a 50 MHz high precision master oscillator, the equivalent of a 100 GHz clock frequency standard is achieved. Absolute accuracy and stability of the digitizer are determined by the external 50 MHz master oscillator, which serves as a standard time marker. The start and stop pulses are fast 1 nsec rise time signals, according to the Nuclear Instrument means of tunnel diode discriminators. Firing level of the discriminator define start and stop points between which the time interval is digitized.

  9. Absolute Determination of High DC Voltages by Means of Frequency Measurement

    NASA Astrophysics Data System (ADS)

    Peier, Dirk; Schulz, Bernd

    1983-01-01

    A novel absolute measuring procedure is presented for the definition of fixed points of the voltage in the 100 kV range. The method is based on transit time measurements with accelerated electrons. By utilizing the selective interaction of a monoenergetic electron beam with the electromagnetic field of a special cavity resonator, the voltage is referred to fundamental constants and the base unit second. Possible balance voltages are indicated by a current detector. Experimental investigations are carried out with resonators in the normal conducting range. With a copper resonator operating at the temperature of boiling nitrogen (77 K), the relative uncertainty of the voltage points is estimated to be +/- 4 × 10-4. The technically realizable uncertainty can be reduced to +/- 1 × 10-5 by the proposed application of a superconducting niobium resonator. Thus this measuring device becomes suitable as a primary standard for the high-voltage range.

  10. Evaluation of Point-of-Care Resources for Dietary Supplement Information.

    PubMed

    Montgomery, Ashley E; Beckett, Robert D; Montagano, Kaitlin J; Kutom, Samah

    2018-01-01

    To evaluate 6 tertiary, point-of-care drug information resources' dietary supplement content. This was a cross-sectional evaluation of Lexicomp Natural Products Database, Micromedex Alternative Medicine, Clinical Pharmacology, Natural Medicines, The Review of Natural Products, and Handbook of Nonprescription Drugs. Each resource was evaluated for scope, completeness, consistency, and ease of use. For a sample of 66 supplements, scope scores ranged from 69.7% (Micromedex) to 100% (Natural Medicines). Completeness scores were high considering uses, dose, adverse effects, and mechanism (85.7% to 100%). Overall completeness scores ranged from 82.5% ( Handbook of Nonprescription Drugs) to 100% (Clinical Pharmacology, Natural Medicines, The Review of Natural Products). Consistency scores ranged from 0% ( Handbook of Nonprescription Drugs) to 100% (Natural Medicines, The Review of Natural Products). Mean time to locate and gather information was similar among groups. Resources were similar for completeness and ease of use. Scope and consistency varied depending on the resource.

  11. Women's HIV Disclosure to Family and Friends

    PubMed Central

    Craft, Shonda M.; Reed, Sandra J.

    2012-01-01

    Abstract Previous researchers have documented rates of HIV disclosure to family at discrete time periods, yet none have taken a dynamic approach to this phenomenon. The purpose of this study is to take the next step and provide a retrospective comparison of rates of women's HIV disclosure to family and friends over a 15-year time span. Of particular interest are the possible influences of social network and relationship characteristics on the time-to-disclosure of serostatus. Time-to-disclosure was analyzed from data provided by 125 HIV-positive women. Participants were primarily married or dating (42%), unemployed (79.2%), African American (68%) women with a high school diploma or less (54.4%). Length of time since diagnosis ranged from 1 month to over 19 years (M=7.1 years). Results pointed to statistically significant differences in time-to-disclosure between family, friends, and sexual partners. Additionally, females and persons with whom the participant had more frequent contact were more likely to be disclosed to, regardless of the type of relationship. The results of this study underscore possible challenges with existing studies which have employed point prevalence designs, and point to new methods which could be helpful in family research. PMID:22313348

  12. Development of measurement simulation of the laser dew-point hygrometer using an optical fiber cable

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki

    2005-02-01

    In order to improve the initial and the response times of the Laser Dew-Point Hygrometer (LDH), the measurement simulation was developed on the basis of the loop computation of the surface temperature of a gold plate for dew depostition, the quantity of deposited dew and the intensity of scattered light from the surface of the plate at time interval of 5 sec during measurement. A more detailed relationship between the surface temperature of the plate and the cooling current, and the time constant of the integrator in the control circuit of the LDH were introduced in the simulation program as a function of atmospheric temperature. The simulation was more close to the actual measurement by the LDH. The simulation results indicated the possibility of improving both the times of teh LDH by the increase of the sensitivity of dew and that of the mass transfer coefficient of dew deposited on the plate surface. It was concluded that the initial and the response times could be improved to below 100sec and 120 sec, respectively in the dew-point range at room temperature, that are almost half of the those times of the original LDH.

  13. A noniterative greedy algorithm for multiframe point correspondence.

    PubMed

    Shafique, Khurram; Shah, Mubarak

    2005-01-01

    This paper presents a framework for finding point correspondences in monocular image sequences over multiple frames. The general problem of multiframe point correspondence is NP-hard for three or more frames. A polynomial time algorithm for a restriction of this problem is presented and is used as the basis of the proposed greedy algorithm for the general problem. The greedy nature of the proposed algorithm allows it to be used in real-time systems for tracking and surveillance, etc. In addition, the proposed algorithm deals with the problems of occlusion, missed detections, and false positives by using a single noniterative greedy optimization scheme and, hence, reduces the complexity of the overall algorithm as compared to most existing approaches where multiple heuristics are used for the same purpose. While most greedy algorithms for point tracking do not allow for entry and exit of the points from the scene, this is not a limitation for the proposed algorithm. Experiments with real and synthetic data over a wide range of scenarios and system parameters are presented to validate the claims about the performance of the proposed algorithm.

  14. Short time propagation of a singular wave function: Some surprising results

    NASA Astrophysics Data System (ADS)

    Marchewka, A.; Granot, E.; Schuss, Z.

    2007-08-01

    The Schrödinger evolution of an initially singular wave function was investigated. First it was shown that a wide range of physical problems can be described by initially singular wave function. Then it was demonstrated that outside the support of the initial wave function the time evolution is governed to leading order by the values of the wave function and its derivatives at the singular points. Short-time universality appears where it depends only on a single parameter—the value at the singular point (not even on its derivatives). It was also demonstrated that the short-time evolution in the presence of an absorptive potential is different than in the presence of a nonabsorptive one. Therefore, this dynamics can be harnessed to the determination whether a potential is absorptive or not simply by measuring only the transmitted particles density.

  15. Quality of life in patients with proton-treated pediatric medulloblastoma: Results of a prospective assessment with 5-year follow-up.

    PubMed

    Kamran, Sophia C; Goldberg, Saveli I; Kuhlthau, Karen A; Lawell, Miranda P; Weyman, Elizabeth A; Gallotto, Sara L; Hess, Clayton B; Huang, Mary S; Friedmann, Alison M; Abrams, Annah N; MacDonald, Shannon M; Pulsifer, Margaret B; Tarbell, Nancy J; Ebb, David H; Yock, Torunn I

    2018-06-15

    To the authors' knowledge, health-related quality of life (HRQOL) outcomes are not well described in patients with medulloblastoma. The use of proton radiotherapy (RT) may translate into an improved HRQOL. In the current study, the authors report long-term HRQOL in patients with proton-treated pediatric medulloblastoma. The current study was a prospective cohort HRQOL study of patients with medulloblastoma who were treated with proton RT and enrolled between August 5, 2002, and October 8, 2015. Both child report and parent-proxy report Pediatric Quality of Life Inventory (PedsQL) surveys were collected at baseline during RT and annually thereafter (score range on surveys of 0-100, with higher scores indicating better HRQOL). Patients were dichotomized by clinical/treatment variables and subgroups were compared. Mixed-model analysis was performed to determine the longitudinal trajectory of PedsQL scores. The Student t test was used to compare long-term HRQOL measures with published means from a healthy child population. Survey data were evaluable for 116 patients with a median follow-up of 5 years (range, 1-10.6 years); the median age at the time of diagnosis was 7.6 years (range, 2.1-18.1 years). At baseline, children reported a total core score (TCS) of 65.9, which increased by 1.8 points annually (P<.001); parents reported a TCS of 59.1, which increased by 2.0 points annually. Posterior fossa syndrome adversely affected baseline scores, but these scores significantly improved with time. At the time of last follow-up, children reported a TCS of 76.3, which was 3.3 points lower than that of healthy children (P = .09); parents reported a TCS of 69, which was 11.9 points lower than that of parents of healthy children (P<.001). Increased follow-up time from diagnosis correlated with improved HRQOL scores. HRQOL scores appear to increase over time after treatment in children treated with proton RT for medulloblastoma but remain lower compared with those of parent-proxy reports as well as published means from a healthy normative sample of children. Additional follow-up may translate into continued improvements in HRQOL. Cancer 2018. © 2018 American Cancer Society. © 2018 American Cancer Society.

  16. Optimized stereo matching in binocular three-dimensional measurement system using structured light.

    PubMed

    Liu, Kun; Zhou, Changhe; Wei, Shengbin; Wang, Shaoqing; Fan, Xin; Ma, Jianyong

    2014-09-10

    In this paper, we develop an optimized stereo-matching method used in an active binocular three-dimensional measurement system. A traditional dense stereo-matching algorithm is time consuming due to a long search range and the high complexity of a similarity evaluation. We project a binary fringe pattern in combination with a series of N binary band limited patterns. In order to prune the search range, we execute an initial matching before exhaustive matching and evaluate a similarity measure using logical comparison instead of a complicated floating-point operation. Finally, an accurate point cloud can be obtained by triangulation methods and subpixel interpolation. The experiment results verify the computational efficiency and matching accuracy of the method.

  17. Nonequilibrium Tricritical Point in a System with Long-Range Interactions

    NASA Astrophysics Data System (ADS)

    Antoniazzi, Andrea; Fanelli, Duccio; Ruffo, Stefano; Yamaguchi, Yoshiyuki Y.

    2007-07-01

    Systems with long-range interactions display a short-time relaxation towards quasistationary states whose lifetime increases with system size. With reference to the Hamiltonian mean field model, we here show that a maximum entropy principle, based on Lynden-Bell’s pioneering idea of “violent relaxation,” predicts the presence of out-of-equilibrium phase transitions separating the relaxation towards homogeneous (zero magnetization) or inhomogeneous (nonzero magnetization) quasistationary states. When varying the initial condition within a family of “water bags” with different initial magnetization and energy, first- and second-order phase transition lines are found that merge at an out-of-equilibrium tricritical point. Metastability is theoretically predicted and numerically checked around the first-order phase transition line.

  18. Avoided ferromagnetic quantum critical point: unusual short-range ordered state in CeFePO.

    PubMed

    Lausberg, S; Spehling, J; Steppke, A; Jesche, A; Luetkens, H; Amato, A; Baines, C; Krellner, C; Brando, M; Geibel, C; Klauss, H-H; Steglich, F

    2012-11-21

    Cerium 4f electronic spin dynamics in single crystals of the heavy-fermion system CeFePO is studied by means of ac susceptibility, specific heat, and muon-spin relaxation (μSR). Short-range static magnetism occurs below the freezing temperature T(g) ≈ 0.7 K, which prevents the system from accessing a putative ferromagnetic quantum critical point. In the μSR, the sample-averaged muon asymmetry function is dominated by strongly inhomogeneous spin fluctuations below 10 K and exhibits a characteristic time-field scaling relation expected from glassy spin dynamics, strongly evidencing cooperative and critical spin fluctuations. The overall behavior can be ascribed neither to canonical spin glasses nor other disorder-driven mechanisms.

  19. Decorrelation of the static and dynamic length scales in hard-sphere glass formers.

    PubMed

    Charbonneau, Patrick; Tarjus, Gilles

    2013-04-01

    We show that, in the equilibrium phase of glass-forming hard-sphere fluids in three dimensions, the static length scales tentatively associated with the dynamical slowdown and the dynamical length characterizing spatial heterogeneities in the dynamics unambiguously decorrelate. The former grow at a much slower rate than the latter when density increases. This observation is valid for the dynamical range that is accessible to computer simulations, which roughly corresponds to that accessible in colloidal experiments. We also find that, in this same range, no one-to-one correspondence between relaxation time and point-to-set correlation length exists. These results point to the coexistence of several relaxation mechanisms in the dynamically accessible regime of three-dimensional hard-sphere glass formers.

  20. Breaking through the bandwidth barrier in distributed fiber vibration sensing by sub-Nyquist randomized sampling

    NASA Astrophysics Data System (ADS)

    Zhang, Jingdong; Zhu, Tao; Zheng, Hua; Kuang, Yang; Liu, Min; Huang, Wei

    2017-04-01

    The round trip time of the light pulse limits the maximum detectable frequency response range of vibration in phase-sensitive optical time domain reflectometry (φ-OTDR). We propose a method to break the frequency response range restriction of φ-OTDR system by modulating the light pulse interval randomly which enables a random sampling for every vibration point in a long sensing fiber. This sub-Nyquist randomized sampling method is suits for detecting sparse-wideband- frequency vibration signals. Up to MHz resonance vibration signal with over dozens of frequency components and 1.153MHz single frequency vibration signal are clearly identified for a sensing range of 9.6km with 10kHz maximum sampling rate.

  1. Real-time dose adjustment using point-of-care platelet reactivity testing in a double-blind study of prasugrel in children with sickle cell anaemia.

    PubMed

    Jakubowski, Joseph A; Hoppe, Carolyn C; Zhou, Chunmei; Smith, Brendan E; Brown, Patricia B; Heath, Lori E; Inusa, Baba; Rees, David C; Small, David S; Gupta, Neehar; Yao, Suqin; Heeney, Matthew; Kanter, Julie

    2017-02-28

    Patients with sickle cell anaemia (SCA) have vaso-occlusive crises resulting from occlusive hypoxic-ischaemic injury. Prasugrel inhibits platelet activation and aggregation involved in SCA pathophysiology. Determining Effects of Platelet Inhibition on Vaso-Occlusive Events (DOVE) was a phase 3, double-blind, randomised, placebo-controlled trial assessing prasugrel efficacy. DOVE sought to bring patients' P2Y12 reaction unit (PRU) value within a targeted range via prasugrel dose adjustments using encrypted VerifyNow P2Y12 ® (VN-P2Y12) point-of-care testing and an interactive voice-response system (IVRS). After PRU determination, randomised patients received 0.08 mg/kg/day prasugrel or placebo. Encrypted PRUs and IVRS provided double-blind dose adjustments to achieve a defined PRU target range of 136-231; placebo patients had mock titrations. Of 341 randomised patients, 166 placebo and 160 prasugrel patients reached the fully titrated dose (FTD). Most prasugrel patients (n=104, 65 %) remained on the initial 0.08 mg/kg dose; doses escalations occurred in 23 % of patients (n=36). Mean PRUs for the pharmacodynamic population at baseline were similar in the prasugrel (273 ± 44.9) and placebo groups (273 ± 51.7), with significant reductions in PRU (p<0.001) for prasugrel patients at the FTD and at 9 months. Concomitant use of hydroxyurea did not affect platelet reactivity at any time. The majority of prasugrel patients (n=135, 84.4 %) at the FTD were within the target range of 136-231 PRUs. Mean VN-P2Y12 percentage inhibition at baseline was similar in the prasugrel (2.8  ± 5.4 %) and placebo groups (2.0 ± 4.7 %); prasugrel patients had significant increases in inhibition (p<0.001) at FTD and at 9 months. Patients with higher PRU values at baseline required higher prasugrel doses to bring PRU within the prespecified range. DOVE is the first study to successfully employ double-blind, real-time, encrypted, point-of-care platelet testing and IVRS to dose-adjust antiplatelet therapy to a targeted range of platelet inhibition.

  2. Deep-Focusing Time-Distance Helioseismology

    NASA Technical Reports Server (NTRS)

    Duvall, T. L., Jr.; Jensen, J. M.; Kosovichev, A. G.; Birch, A. C.; Fisher, Richard R. (Technical Monitor)

    2001-01-01

    Much progress has been made by measuring the travel times of solar acoustic waves from a central surface location to points at equal arc distance away. Depth information is obtained from the range of arc distances examined, with the larger distances revealing the deeper layers. This method we will call surface-focusing, as the common point, or focus, is at the surface. To obtain a clearer picture of the subsurface region, it would, no doubt, be better to focus on points below the surface. Our first attempt to do this used the ray theory to pick surface location pairs that would focus on a particular subsurface point. This is not the ideal procedure, as Born approximation kernels suggest that this focus should have zero sensitivity to sound speed inhomogeneities. However, the sensitivity is concentrated below the surface in a much better way than the old surface-focusing method, and so we expect the deep-focusing method to be more sensitive. A large sunspot group was studied by both methods. Inversions based on both methods will be compared.

  3. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    NASA Technical Reports Server (NTRS)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  4. Impact of Infrared Lunar Laser Ranging on Lunar Dynamics

    NASA Astrophysics Data System (ADS)

    Viswanathan, Vishnu; Fienga, Agnès; Manche, Hervé; Gastineau, Mickael; Courde, Clément; Torre, Jean-Marie; Exertier, Pierre; Laskar, Jacques; LLR Observers : Astrogeo-OCA, Apache Point, McDonald Laser Ranging Station, Haleakala Observatory, Matera Laser Ranging Observatory

    2016-10-01

    Since 2015, in addition to the traditional green (532nm), infrared (1064nm) has been the preferred wavelength for lunar laser ranging at the Calern lunar laser ranging (LLR) site in France. Due to the better atmospheric transmission of IR with respect to Green, nearly 3 times the number of normal points have been obtained in IR than in Green [ C.Courde et al 2016 ]. In our study, in addition to the historical data obtained from various other LLR sites, we include the recent IR normal points obtained from Calern over the 1 year time span (2015-2016), constituting about 4.2% of data spread over 46 years of LLR. Near even distribution of data provided by IR on both the spatial and temporal domain, helps us to improve constraints on the internal structure of the Moon modeled within the planetary ephemeris : INPOP [ Fienga et al 2015 ]. IERS recommended models have been used in the data reduction software GINS (GRGS,CNES) [ V.Viswanathan et al 2015 ]. Constraints provided by GRAIL, on the Lunar gravitational potential and Love numbers have been taken into account in the least-square fit procedure. New estimates on the dynamical parameters of the lunar core will be presented.

  5. Nucleation in the presence of long-range interactions. [performed on ferroelectric barium titanate

    NASA Technical Reports Server (NTRS)

    Chandra, P.

    1989-01-01

    Unlike droplet nucleation near a liquid-gas critical point, the decay of metastable phases in crystalline materials is strongly affected by the presence of long-range forces. Field quench experiments performed on the ferroelectric barium titanate indicate that nucleation in this material is markedly different from that observed in liquids. In this paper, a theory for nucleation at a first-order phase transition in which the mediating forces are long range is presented. It is found that the long-range force induces cooperative nucleation and growth processes, and that this feedback mechanism produces a well-defined delay time with a sharp onset in the transformation to the stable phase. Closed-form expressions for the characteristic onset time and width of the transition are developed, in good agreement with numerical and experimental results.

  6. Stare and chase of space debris targets using real-time derived pointing data

    NASA Astrophysics Data System (ADS)

    Steindorfer, Michael A.; Kirchner, Georg; Koidl, Franz; Wang, Peiyuan; Antón, Alfredo; Fernández Sánchez, Jaime; Merz, Klaus

    2017-09-01

    We successfully demonstrate Stare & Chase: Space debris laser ranging to uncooperative targets has been achieved without a priori knowledge of any orbital information. An analog astronomy CCD with a standard objective, piggyback mounted on our 50 cm Graz SLR receive telescope, 'stares' into the sky in a fixed direction. The CCD records the stellar background within a field of view of approx. 7°. From the stellar X/Y positions on the sensor a plate solving algorithm determines the pointing data of the image center with an accuracy of approx. 15 arc seconds. If a sunlit target passes through this field of view, its equatorial coordinates are calculated, stored and a Consolidated Prediction Format (CPF) file is created in near real time. The derived CPF data is used to start laser ranging ('chase' the object) within the same pass to retrieve highly accurate distance information. A comparison of Stare & Chase CPFs with standard TLE predictions shows the possibilities and limits of this method.

  7. Early arthroscopic release in stiff shoulder

    PubMed Central

    Sabat, Dhananjaya; Kumar, Vinod

    2008-01-01

    Purpose: To evaluate the results of early arthroscopic release in the patients of stiff shoulder Methods: Twenty patients of stiff shoulder, who had symptoms for at least three months and failed to improve with steroid injections and physical therapy of 6 weeks duration, underwent arthroscopic release. The average time between onset of symptoms and the time of surgery was 4 months and 2 weeks. The functional outcome was evaluated using ASES and Constant and Murley scoring systems. Results: All the patients showed significant improvement in the range of motion and relief of pain by end of three months following the procedure. At 12 months, mean improvement in ASES score is 38 points and Constant and Murley score is 4O.5 points. All patients returned to work by 3-5 months (average -4.5 months). Conclusion: Early arthroscopic release showed promising results with reliable increase in range of motion, early relief of symptoms and consequent early return to work. So it is highly recommended in properly selected patients. Level of evidence: Level IV PMID:20300309

  8. New 'Molecular Movie' Reveals Ultrafast Chemistry in Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minitti, Michael

    2015-06-22

    Scientists for the first time tracked ultrafast structural changes, captured in quadrillionths-of-a-second steps, as ring-shaped gas molecules burst open and unraveled. Ring-shaped molecules are abundant in biochemistry and also form the basis for many drug compounds. The study points the way to a wide range of real-time X-ray studies of gas-based chemical reactions that are vital to biological processes.

  9. New 'Molecular Movie' Reveals Ultrafast Chemistry in Motion

    ScienceCinema

    Minitti, Michael

    2018-02-14

    Scientists for the first time tracked ultrafast structural changes, captured in quadrillionths-of-a-second steps, as ring-shaped gas molecules burst open and unraveled. Ring-shaped molecules are abundant in biochemistry and also form the basis for many drug compounds. The study points the way to a wide range of real-time X-ray studies of gas-based chemical reactions that are vital to biological processes.

  10. Proton radiography and proton computed tomography based on time-resolved dose measurements

    NASA Astrophysics Data System (ADS)

    Testa, Mauro; Verburg, Joost M.; Rose, Mark; Min, Chul Hee; Tang, Shikui; Hassane Bentefour, El; Paganetti, Harald; Lu, Hsiao-Ming

    2013-11-01

    We present a proof of principle study of proton radiography and proton computed tomography (pCT) based on time-resolved dose measurements. We used a prototype, two-dimensional, diode-array detector capable of fast dose rate measurements, to acquire proton radiographic images expressed directly in water equivalent path length (WEPL). The technique is based on the time dependence of the dose distribution delivered by a proton beam traversing a range modulator wheel in passive scattering proton therapy systems. The dose rate produced in the medium by such a system is periodic and has a unique pattern in time at each point along the beam path and thus encodes the WEPL. By measuring the time dose pattern at the point of interest, the WEPL to this point can be decoded. If one measures the time-dose patterns at points on a plane behind the patient for a beam with sufficient energy to penetrate the patient, the obtained 2D distribution of the WEPL forms an image. The technique requires only a 2D dosimeter array and it uses only the clinical beam for a fraction of second with negligible dose to patient. We first evaluated the accuracy of the technique in determining the WEPL for static phantoms aiming at beam range verification of the brain fields of medulloblastoma patients. Accurate beam ranges for these fields can significantly reduce the dose to the cranial skin of the patient and thus the risk of permanent alopecia. Second, we investigated the potential features of the technique for real-time imaging of a moving phantom. Real-time tumor tracking by proton radiography could provide more accurate validations of tumor motion models due to the more sensitive dependence of proton beam on tissue density compared to x-rays. Our radiographic technique is rapid (˜100 ms) and simultaneous over the whole field, it can image mobile tumors without the problem of interplay effect inherently challenging for methods based on pencil beams. Third, we present the reconstructed pCT images of a cylindrical phantom containing inserts of different materials. As for all conventional pCT systems, the method illustrated in this work produces tomographic images that are potentially more accurate than x-ray CT in providing maps of proton relative stopping power (RSP) in the patient without the need for converting x-ray Hounsfield units to proton RSP. All phantom tests produced reasonable results, given the currently limited spatial and time resolution of the prototype detector. The dose required to produce one radiographic image, with the current settings, is ˜0.7 cGy. Finally, we discuss a series of techniques to improve the resolution and accuracy of radiographic and tomographic images for the future development of a full-scale detector.

  11. Enhancing Early Childhood Mental Health Primary Care Services: Evaluation of MA Project LAUNCH.

    PubMed

    Molnar, Beth E; Lees, Kristin E; Roper, Kate; Byars, Natasha; Méndez-Peñate, Larisa; Moulin, Christy; McMullen, William; Wolfe, Jessica; Allen, Deborah

    2018-06-16

    Objectives The purpose of this study was to evaluate the efficacy of an innovative early childhood mental health intervention, Massachusetts Project LAUNCH. Early childhood mental health clinicians and family partners (paraprofessionals with lived experience) were embedded within community pediatric medical homes. Methods A longitudinal study design was used to test the hypotheses that (1) children who received services would experience decreased social, emotional and behavioral problems over time and (2) caregivers' stress and depressive symptoms would decrease over time. Families who were enrolled in services and who consented to participate in the evaluation study were included in analyses (N = 225). Individual growth models were used to test longitudinal effects among MA LAUNCH participants (children and caregivers) over three time points using screening tools. Results Analyses showed that LAUNCH children who scored in age-specific clinically significant ranges of social, emotional and behavioral problems at Time 1 scored in the normal range on average by Time 3. Caregivers' stress and depressive symptoms also declined across the three time points. Results support hypotheses that the LAUNCH intervention improved social and emotional health for children and caregivers. Conclusions for Practice This study led to sustainability efforts, an expansion of the model to three additional communities across the state and development of an online toolkit for other communities interested in implementation.

  12. Impact of survey workflow on precision and accuracy of terrestrial LiDAR datasets

    NASA Astrophysics Data System (ADS)

    Gold, P. O.; Cowgill, E.; Kreylos, O.

    2009-12-01

    Ground-based LiDAR (Light Detection and Ranging) survey techniques are enabling remote visualization and quantitative analysis of geologic features at unprecedented levels of detail. For example, digital terrain models computed from LiDAR data have been used to measure displaced landforms along active faults and to quantify fault-surface roughness. But how accurately do terrestrial LiDAR data represent the true ground surface, and in particular, how internally consistent and precise are the mosaiced LiDAR datasets from which surface models are constructed? Addressing this question is essential for designing survey workflows that capture the necessary level of accuracy for a given project while minimizing survey time and equipment, which is essential for effective surveying of remote sites. To address this problem, we seek to define a metric that quantifies how scan registration error changes as a function of survey workflow. Specifically, we are using a Trimble GX3D laser scanner to conduct a series of experimental surveys to quantify how common variables in field workflows impact the precision of scan registration. Primary variables we are testing include 1) use of an independently measured network of control points to locate scanner and target positions, 2) the number of known-point locations used to place the scanner and point clouds in 3-D space, 3) the type of target used to measure distances between the scanner and the known points, and 4) setting up the scanner over a known point as opposed to resectioning of known points. Precision of the registered point cloud is quantified using Trimble Realworks software by automatic calculation of registration errors (errors between locations of the same known points in different scans). Accuracy of the registered cloud (i.e., its ground-truth) will be measured in subsequent experiments. To obtain an independent measure of scan-registration errors and to better visualize the effects of these errors on a registered point cloud, we scan from multiple locations an object of known geometry (a cylinder mounted above a square box). Preliminary results show that even in a controlled experimental scan of an object of known dimensions, there is significant variability in the precision of the registered point cloud. For example, when 3 scans of the central object are registered using 4 known points (maximum time, maximum equipment), the point clouds align to within ~1 cm (normal to the object surface). However, when the same point clouds are registered with only 1 known point (minimum time, minimum equipment), misalignment of the point clouds can range from 2.5 to 5 cm, depending on target type. The greater misalignment of the 3 point clouds when registered with fewer known points stems from the field method employed in acquiring the dataset and demonstrates the impact of field workflow on LiDAR dataset precision. By quantifying the degree of scan mismatch in results such as this, we can provide users with the information needed to maximize efficiency in remote field surveys.

  13. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  14. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  15. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...

  16. 33 CFR 334.200 - Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air...) The regulations. (i) Through navigation of surface craft outside the target areas will be permitted at...

  17. Accuracy in GPS/Acoustic positioning on a moored buoy moving around far from the optimal position

    NASA Astrophysics Data System (ADS)

    Imano, M.; Kido, M.; Ohta, Y.; Takahashi, N.; Fukuda, T.; Ochi, H.; Hino, R.

    2015-12-01

    For detecting the seafloor crustal deformation and Tsunami associated with large earthquakes in real-time, it is necessary to monitor them just above the possible source region. For this purpose, we have been dedicated in developing a real-time continuous observation system using a multi-purpose moored buoy. Sea-trials of the system have been carried out near the Nanakai trough in 2013 and 2014 (Takahashi et al., 2014). We especially focused on the GPS/Acoustic measurement (GPS/A) in the system for horizontal crustal movement. The GPS/A on a moored buoy has a critical drawback compared to the traditional ones, in which the data can be stacked over ranging points fixed at an optimal position. Accuracy in positioning with a single ranging from an arbitrary point is the subject to be improved in this study. Here, we report the positioning results in the buoy system using data in the 2014 sea-trial and demonstrate the improvement of the result. We also address the potential resolving power in the positioning using synthetic tests. The target GPS/A site consists of six seafloor transponders (PXPs) forming a small inner- and a large outer-triangles. The bottom of the moored cable is anchored nearly the center of the triangles. In the sea-trial, 11 times successive ranging was scheduled once a week, and we plotted positioning results from different buoy position. We confirmed that scatter in positioning using six PXPs simultaneously is ten times smaller than that using individual triangle separately. Next, we modified the definition of the PXP array geometry using data obtained in a campaign observation. Definition of an array geometry is insensitive as far as ranging is made in the same position, however, severely affects the positioning when ranging is made from various positions like the moored buoy. The modified PXP array is slightly smaller and 2m deeper than the original one. We found that the scatter of positioning results in the sea-trial is reduced from 4m to 1.7m with the modified geometry. Finally we produced a synthetic data with an artificial error in the array geometry and evaluated its effect on the positioning as a function of ranging point. This is interpreted with potential resolving power formulated in Kido (2007). In the presentation, we will show the results of synthetic test for systematic variation of the error condition.

  18. A longitudinal analysis of depressive symptoms among Asian and Pacific Islander mothers at-risk for child maltreatment.

    PubMed

    Ta, Van M; Juon, Hee-Soon; Gielen, Andrea C; Steinwachs, Donald; McFarlane, Elizabeth; Duggan, Anne

    2009-02-01

    This longitudinal study examined racial differences in depressive symptoms at three time points among Asian, Native Hawaiian/Other Pacific Islander (NHOPI) and white mothers at-risk for child maltreatment (n = 616). The proportion of mothers with depressive symptoms ranged from 28 to 35% at all time points. Adjusted analyses revealed that Asian and NHOPI mothers were significantly more likely than white mothers to have depressive symptoms but this disparity was present only among families at mild/moderate risk for child maltreatment. Future research should identify ways to reduce this disparity and involve the Asian and NHOPI communities in prevention and treatment program design and implementation.

  19. Magnetic recording performance of keepered media

    NASA Astrophysics Data System (ADS)

    Coughlin, T. M.; Tang, Y. S.; Velu, E. M. T.; Lairson, B.

    1997-04-01

    Using low flying and proximity inductive heads, keepered media show improved on- and off-track performance leading us to conclude that a greater than 20% areal density improvement is possible with a keeper layer over the magnetic storage layer. For Sendust keeper layers there is an optimal range of thickness and an optimal bias point for best performance. There are both amplitude and timing asymmetries that are functions of the read-back bias. For a peak detect channel the best performance corresponds to the minimum timing asymmetry although this is not the point where the pulses are narrowest. Keepered media may have an advantage in total jitter and partial erasure. NLTS is almost identical for keepered versus unkeepered media.

  20. Seismic Line Location Map Hot Pot Project, Humboldt County, Nevada 2010

    DOE Data Explorer

    Lane, Michael

    2010-01-01

    Seismic Line Location Map Hot Pot Project, Humboldt County, Nevada 2010. ArcGIS map package containing topographic base map, Township and Range layer, Oski BLM and private leases at time of survey, and locations, with selected shot points, of the five seismic lines.

  1. Improved Real-Time Scan Matching Using Corner Features

    NASA Astrophysics Data System (ADS)

    Mohamed, H. A.; Moussa, A. M.; Elhabiby, M. M.; El-Sheimy, N.; Sesay, Abu B.

    2016-06-01

    The automation of unmanned vehicle operation has gained a lot of research attention, in the last few years, because of its numerous applications. The vehicle localization is more challenging in indoor environments where absolute positioning measurements (e.g. GPS) are typically unavailable. Laser range finders are among the most widely used sensors that help the unmanned vehicles to localize themselves in indoor environments. Typically, automatic real-time matching of the successive scans is performed either explicitly or implicitly by any localization approach that utilizes laser range finders. Many accustomed approaches such as Iterative Closest Point (ICP), Iterative Matching Range Point (IMRP), Iterative Dual Correspondence (IDC), and Polar Scan Matching (PSM) handles the scan matching problem in an iterative fashion which significantly affects the time consumption. Furthermore, the solution convergence is not guaranteed especially in cases of sharp maneuvers or fast movement. This paper proposes an automated real-time scan matching algorithm where the matching process is initialized using the detected corners. This initialization step aims to increase the convergence probability and to limit the number of iterations needed to reach convergence. The corner detection is preceded by line extraction from the laser scans. To evaluate the probability of line availability in indoor environments, various data sets, offered by different research groups, have been tested and the mean numbers of extracted lines per scan for these data sets are ranging from 4.10 to 8.86 lines of more than 7 points. The set of all intersections between extracted lines are detected as corners regardless of the physical intersection of these line segments in the scan. To account for the uncertainties of the detected corners, the covariance of the corners is estimated using the extracted lines variances. The detected corners are used to estimate the transformation parameters between the successive scan using least squares. These estimated transformation parameters are used to calculate an adjusted initialization for scan matching process. The presented method can be employed solely to match the successive scans and also can be used to aid other accustomed iterative methods to achieve more effective and faster converge. The performance and time consumption of the proposed approach is compared with ICP algorithm alone without initialization in different scenarios such as static period, fast straight movement, and sharp manoeuvers.

  2. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    PubMed

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  3. Testing gravity with Lunar Laser Ranging: An update on the APOLLO experiment

    NASA Astrophysics Data System (ADS)

    Battat, James; Colmenares, Nick; Davis, Rodney; Ruixue, Louisa Huang; Murphy, Thomas W., Jr.; Apollo Collaboration

    2017-01-01

    The mystery of dark energy and the incompatibility of quantum mechanics and General Relativity indicate the need for precision experimental probes of gravitational physics. The Earth-Moon-Sun system is a fertile laboratory for such tests. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) makes optical range measurements to retro-reflectors on the Moon with one millimeter precision. These measurements of the lunar orbit enable incisive constraints on gravitational phenomena such as the Strong Equivalence Principle and dG / dt (among others). Until now, the APOLLO team had not been able to assess the accuracy of our data, in large part because known limitations to lunar range models ensure data-model residuals at the centimeter scale. To directly measure the APOLLO system timing accuracy, we have built an Absolute timing Calibration System (ACS) that delivers photons to our detector at known, stable time intervals using a pulsed fiber laser locked to a cesium frequency standard. This scheme provides real-time calibration of the APOLLO system timing, synchronous with the range measurements. We installed the calibration system in August, 2016. In this talk, we will describe the ACS design, and present present preliminary results from the ACS calibration campaign. We acknowledge the support of both NSF and NASA

  4. The multiple time scales of sleep dynamics as a challenge for modelling the sleeping brain.

    PubMed

    Olbrich, Eckehard; Claussen, Jens Christian; Achermann, Peter

    2011-10-13

    A particular property of the sleeping brain is that it exhibits dynamics on very different time scales ranging from the typical sleep oscillations such as sleep spindles and slow waves that can be observed in electroencephalogram (EEG) segments of several seconds duration over the transitions between the different sleep stages on a time scale of minutes to the dynamical processes involved in sleep regulation with typical time constants in the range of hours. There is an increasing body of work on mathematical and computational models addressing these different dynamics, however, usually considering only processes on a single time scale. In this paper, we review and present a new analysis of the dynamics of human sleep EEG at the different time scales and relate the findings to recent modelling efforts pointing out both the achievements and remaining challenges.

  5. Performance analysis of a dual-tree algorithm for computing spatial distance histograms

    PubMed Central

    Chen, Shaoping; Tu, Yi-Cheng; Xia, Yuni

    2011-01-01

    Many scientific and engineering fields produce large volume of spatiotemporal data. The storage, retrieval, and analysis of such data impose great challenges to database systems design. Analysis of scientific spatiotemporal data often involves computing functions of all point-to-point interactions. One such analytics, the Spatial Distance Histogram (SDH), is of vital importance to scientific discovery. Recently, algorithms for efficient SDH processing in large-scale scientific databases have been proposed. These algorithms adopt a recursive tree-traversing strategy to process point-to-point distances in the visited tree nodes in batches, thus require less time when compared to the brute-force approach where all pairwise distances have to be computed. Despite the promising experimental results, the complexity of such algorithms has not been thoroughly studied. In this paper, we present an analysis of such algorithms based on a geometric modeling approach. The main technique is to transform the analysis of point counts into a problem of quantifying the area of regions where pairwise distances can be processed in batches by the algorithm. From the analysis, we conclude that the number of pairwise distances that are left to be processed decreases exponentially with more levels of the tree visited. This leads to the proof of a time complexity lower than the quadratic time needed for a brute-force algorithm and builds the foundation for a constant-time approximate algorithm. Our model is also general in that it works for a wide range of point spatial distributions, histogram types, and space-partitioning options in building the tree. PMID:21804753

  6. The calibration of photographic and spectroscopic films. 1: Film batch variations of reciprocity failure in IIaO film. 2: Thermal and aging effects in relationship to reciprocity failure. 3: Shifting of reciprocity failure points as a function of thermal and aging effects

    NASA Technical Reports Server (NTRS)

    Peters, K. A.; Atkinson, P. F.; Hammond, E. C., Jr.

    1986-01-01

    Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. The results indicate that film batch differences, temperature, and aging play an important role in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.

  7. Evaluating lidar point densities for effective estimation of aboveground biomass

    USGS Publications Warehouse

    Wu, Zhuoting; Dye, Dennis G.; Stoker, Jason M.; Vogel, John M.; Velasco, Miguel G.; Middleton, Barry R.

    2016-01-01

    The U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) was recently established to provide airborne lidar data coverage on a national scale. As part of a broader research effort of the USGS to develop an effective remote sensing-based methodology for the creation of an operational biomass Essential Climate Variable (Biomass ECV) data product, we evaluated the performance of airborne lidar data at various pulse densities against Landsat 8 satellite imagery in estimating above ground biomass for forests and woodlands in a study area in east-central Arizona, U.S. High point density airborne lidar data, were randomly sampled to produce five lidar datasets with reduced densities ranging from 0.5 to 8 point(s)/m2, corresponding to the point density range of 3DEP to provide national lidar coverage over time. Lidar-derived aboveground biomass estimate errors showed an overall decreasing trend as lidar point density increased from 0.5 to 8 points/m2. Landsat 8-based aboveground biomass estimates produced errors larger than the lowest lidar point density of 0.5 point/m2, and therefore Landsat 8 observations alone were ineffective relative to airborne lidar for generating a Biomass ECV product, at least for the forest and woodland vegetation types of the Southwestern U.S. While a national Biomass ECV product with optimal accuracy could potentially be achieved with 3DEP data at 8 points/m2, our results indicate that even lower density lidar data could be sufficient to provide a national Biomass ECV product with accuracies significantly higher than that from Landsat observations alone.

  8. Additional Effect of Static Ultrasound and Diadynamic Currents on Myofascial Trigger Points in a Manual Therapy Program for Patients With Chronic Neck Pain: A Randomized Clinical Trial.

    PubMed

    Dibai-Filho, Almir Vieira; de Oliveira, Alessandra Kelly; Girasol, Carlos Eduardo; Dias, Fabiana Rodrigues Cancio; Guirro, Rinaldo Roberto de Jesus

    2017-04-01

    To assess the additional effect of static ultrasound and diadynamic currents on myofascial trigger points in a manual therapy program to treat individuals with chronic neck pain. A single-blind randomized trial was conducted. Both men and women, between ages 18 and 45, with chronic neck pain and active myofascial trigger points in the upper trapezius were included in the study. Subjects were assigned to 3 different groups: group 1 (n = 20) was treated with manual therapy; group 2 (n = 20) was treated with manual therapy and static ultrasound; group 3 (n = 20) was treated with manual therapy and diadynamic currents. Individuals were assessed before the first treatment session, 48 hours after the first treatment session, 48 hours after the tenth treatment session, and 4 weeks after the last session. There was no group-versus-time interaction for Numeric Rating Scale, Neck Disability Index, Pain-Related Self-Statement Scale, pressure pain threshold, cervical range of motion, and skin temperature (F-value range, 0.089-1.961; P-value range, 0.106-0.977). Moreover, we found no differences between groups regarding electromyographic activity (P > 0.05). The use of static ultrasound or diadynamic currents on myofascial trigger points in upper trapezius associated with a manual therapy program did not generate greater benefits than manual therapy alone.

  9. Interferometric Dynamic Measurement: Techniques Based on High-Speed Imaging or a Single Photodetector

    PubMed Central

    Fu, Yu; Pedrini, Giancarlo

    2014-01-01

    In recent years, optical interferometry-based techniques have been widely used to perform noncontact measurement of dynamic deformation in different industrial areas. In these applications, various physical quantities need to be measured in any instant and the Nyquist sampling theorem has to be satisfied along the time axis on each measurement point. Two types of techniques were developed for such measurements: one is based on high-speed cameras and the other uses a single photodetector. The limitation of the measurement range along the time axis in camera-based technology is mainly due to the low capturing rate, while the photodetector-based technology can only do the measurement on a single point. In this paper, several aspects of these two technologies are discussed. For the camera-based interferometry, the discussion includes the introduction of the carrier, the processing of the recorded images, the phase extraction algorithms in various domains, and how to increase the temporal measurement range by using multiwavelength techniques. For the detector-based interferometry, the discussion mainly focuses on the single-point and multipoint laser Doppler vibrometers and their applications for measurement under extreme conditions. The results show the effort done by researchers for the improvement of the measurement capabilities using interferometry-based techniques to cover the requirements needed for the industrial applications. PMID:24963503

  10. Precipitation of silicon from splat-cooled Al-Si alloys

    NASA Technical Reports Server (NTRS)

    Matyja, H.; Russell, K. C.; Grant, N. J.; Giessen, B. C.

    1975-01-01

    Splat cooled Al-Si solid solutions with 1 to 11 at.% Si were prepared and their precipitation kinetics were studied by transmission electron microscopy. The time required for appearance of particles visible at a magnification of 35,000 times was determined at temperatures between 248 K and 573 K. The resulting Arrhenius plots yielded activation energies ranging from 55 to 40 plus or minus 2kJ/mol over the composition range. Precipitate densities were higher and denuded zones of 100 to 150 nm were narrower than in comparable solid quenched samples. The activation energies are explained in terms of excess point defect concentrations.

  11. Using natural archives to detect climate and environmental tipping points in the Earth System

    NASA Astrophysics Data System (ADS)

    Thomas, Zoë A.

    2016-11-01

    'Tipping points' in the Earth system are characterised by a nonlinear response to gradual forcing, and may have severe and wide-ranging impacts. Many abrupt events result from simple underlying system dynamics termed 'critical transitions' or 'bifurcations'. One of the best ways to identify and potentially predict threshold behaviour in the climate system is through analysis of natural ('palaeo') archives. Specifically, on the approach to a tipping point, early warning signals can be detected as characteristic fluctuations in a time series as a system loses stability. Testing whether these early warning signals can be detected in highly complex real systems is a key challenge, since much work is either theoretical or only tested with simple models. This is particularly problematic in palaeoclimate and palaeoenvironmental records with low resolution, non-equidistant data, which can limit accurate analysis. Here, a range of different datasets are examined to explore generic rules that can be used to detect such dramatic events. A number of key criteria are identified to be necessary for the reliable identification of early warning signals in natural archives, most crucially, the need for a low-noise record of sufficient data length, resolution and accuracy. A deeper understanding of the underlying system dynamics is required to inform the development of more robust system-specific indicators, or to indicate the temporal resolution required, given a known forcing. This review demonstrates that time series precursors from natural archives provide a powerful means of forewarning tipping points within the Earth System.

  12. Algorithms for Efficient Computation of Transfer Functions for Large Order Flexible Systems

    NASA Technical Reports Server (NTRS)

    Maghami, Peiman G.; Giesy, Daniel P.

    1998-01-01

    An efficient and robust computational scheme is given for the calculation of the frequency response function of a large order, flexible system implemented with a linear, time invariant control system. Advantage is taken of the highly structured sparsity of the system matrix of the plant based on a model of the structure using normal mode coordinates. The computational time per frequency point of the new computational scheme is a linear function of system size, a significant improvement over traditional, still-matrix techniques whose computational times per frequency point range from quadratic to cubic functions of system size. This permits the practical frequency domain analysis of systems of much larger order than by traditional, full-matrix techniques. Formulations are given for both open- and closed-loop systems. Numerical examples are presented showing the advantages of the present formulation over traditional approaches, both in speed and in accuracy. Using a model with 703 structural modes, the present method was up to two orders of magnitude faster than a traditional method. The present method generally showed good to excellent accuracy throughout the range of test frequencies, while traditional methods gave adequate accuracy for lower frequencies, but generally deteriorated in performance at higher frequencies with worst case errors being many orders of magnitude times the correct values.

  13. Arima model and exponential smoothing method: A comparison

    NASA Astrophysics Data System (ADS)

    Wan Ahmad, Wan Kamarul Ariffin; Ahmad, Sabri

    2013-04-01

    This study shows the comparison between Autoregressive Moving Average (ARIMA) model and Exponential Smoothing Method in making a prediction. The comparison is focused on the ability of both methods in making the forecasts with the different number of data sources and the different length of forecasting period. For this purpose, the data from The Price of Crude Palm Oil (RM/tonne), Exchange Rates of Ringgit Malaysia (RM) in comparison to Great Britain Pound (GBP) and also The Price of SMR 20 Rubber Type (cents/kg) with three different time series are used in the comparison process. Then, forecasting accuracy of each model is measured by examinethe prediction error that producedby using Mean Squared Error (MSE), Mean Absolute Percentage Error (MAPE), and Mean Absolute deviation (MAD). The study shows that the ARIMA model can produce a better prediction for the long-term forecasting with limited data sources, butcannot produce a better prediction for time series with a narrow range of one point to another as in the time series for Exchange Rates. On the contrary, Exponential Smoothing Method can produce a better forecasting for Exchange Rates that has a narrow range of one point to another for its time series, while itcannot produce a better prediction for a longer forecasting period.

  14. Trends and advances in food analysis by real-time polymerase chain reaction.

    PubMed

    Salihah, Nur Thaqifah; Hossain, Mohammad Mosharraf; Lubis, Hamadah; Ahmed, Minhaz Uddin

    2016-05-01

    Analyses to ensure food safety and quality are more relevant now because of rapid changes in the quantity, diversity and mobility of food. Food-contamination must be determined to maintain health and up-hold laws, as well as for ethical and cultural concerns. Real-time polymerase chain reaction (RT-PCR), a rapid and inexpensive quantitative method to detect the presence of targeted DNA-segments in samples, helps in determining both accidental and intentional adulterations of foods by biological contaminants. This review presents recent developments in theory, techniques, and applications of RT-PCR in food analyses, RT-PCR addresses the limitations of traditional food analyses in terms of sensitivity, range of analytes, multiplexing ability, cost, time, and point-of-care applications. A range of targets, including species of plants or animals which are used as food ingredients, food-borne bacteria or viruses, genetically modified organisms, and allergens, even in highly processed foods can be identified by RT-PCR, even at very low concentrations. Microfluidic RT-PCR eliminates the separate sample-processing step to create opportunities for point-of-care analyses. We also cover the challenges related to using RT-PCR for food analyses, such as the need to further improve sample handling.

  15. 32 CFR 525.4 - Entry authorization (policy).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Captains of ships and/or marine vessels planning to enter Kwajalein Missile Range shall not knowingly... when practicable). (vi) Purpose of flight. (vii) Plan of flight route, including the point of origin of flight and its designation and estimated date and times of arrival and departure of airspace covered by...

  16. 32 CFR 525.4 - Entry authorization (policy).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Captains of ships and/or marine vessels planning to enter Kwajalein Missile Range shall not knowingly... when practicable). (vi) Purpose of flight. (vii) Plan of flight route, including the point of origin of flight and its designation and estimated date and times of arrival and departure of airspace covered by...

  17. 32 CFR 525.4 - Entry authorization (policy).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Captains of ships and/or marine vessels planning to enter Kwajalein Missile Range shall not knowingly... when practicable). (vi) Purpose of flight. (vii) Plan of flight route, including the point of origin of flight and its designation and estimated date and times of arrival and departure of airspace covered by...

  18. The Broccoli Syndrome: Higher Education's Pubdown Of The Minority Student

    ERIC Educational Resources Information Center

    Tate, Penfield; Delworth, Ursula

    1973-01-01

    The assumption underlying the broccoli syndrome is that minority group students are not familiar with a whole range of Anglo goodies''. This article points out how, as the minority student is enlightened time and again to such facts'', he perceives inherent racism in his enlightener.'' (JC)

  19. 40 CFR 410.35 - New source performance standards (NSPS).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... GUIDELINES AND STANDARDS TEXTILE MILLS POINT SOURCE CATEGORY Low Water Use Processing Subcategory § 410.35... product BOD5 1.4 0.7 COD 2.8 1.4 TSS 1.4 0.7 pH (1) (1) 1 Within the range 6.0 to 9.0 at all times. Water...

  20. 40 CFR 410.35 - New source performance standards (NSPS).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... GUIDELINES AND STANDARDS TEXTILE MILLS POINT SOURCE CATEGORY Low Water Use Processing Subcategory § 410.35... product BOD5 1.4 0.7 COD 2.8 1.4 TSS 1.4 0.7 pH (1) (1) 1 Within the range 6.0 to 9.0 at all times. Water...

  1. Vitamin D status in pregnant women with asthma and its association with adverse respiratory outcomes during infancy.

    PubMed

    Jensen, Megan E; Murphy, V E; Gibson, P G; Mattes, J; Camargo, C A

    2018-01-05

    Vitamin D may influence pregnancy and infant outcomes, especially infant respiratory health. This study aimed to examine vitamin D status in pregnant women with asthma, and whether higher vitamin D levels are associated with fewer adverse respiratory outcomes in their infants. Pregnant women with asthma, recruited from John Hunter Hospital Newcastle Australia (latitude 33°S), had serum total 25-hydroxyvitamin-D (25(OH)D) measured at 16 and 35 weeks gestation. Infant respiratory outcomes were collected at 12 months by parent-report questionnaire. Mother-infant dyads were grouped by serum 25(OH)D during pregnancy: 25(OH)D < 75 nmol/L (at both time-points) versus 25(OH)D ≥ 75 nmol/L (at one or both time-points). In 52 pregnant women with asthma, mean serum 25(OH)D levels were 61 (range 26-110) nmol/L at 16 weeks, and 65 (range 32-116) nmol/L at 35 weeks, gestation. Thirty-one (60%) women had 25(OH)D < 75 nmol/L at both time-points; 21 (40%) had 25(OH)D ≥ 75 nmol/L at one or both time-points. Maternal 25(OH)D < 75 nmol/L during pregnancy was associated with a higher proportion of infants with "wheeze ever" at 12 months, compared with 25(OH)D ≥ 75 nmol/L (71 versus 43%, p = .04). Infant acute-care presentations (45 versus 13%, p = .02) and oral corticosteroid use (26 versus 4%, p = .03) due to "asthma/wheezing" were higher in the maternal group with 25(OH)D < 75 nmol/L, versus ≥75 nmol/L. Most pregnant women with asthma had low vitamin D status, which persisted across gestation. Low maternal vitamin D status was associated with greater risk of adverse respiratory outcomes in their infants, a group at high risk of developing childhood asthma.

  2. Sleep restriction therapy for insomnia is associated with reduced objective total sleep time, increased daytime somnolence, and objectively impaired vigilance: implications for the clinical management of insomnia disorder.

    PubMed

    Kyle, Simon D; Miller, Christopher B; Rogers, Zoe; Siriwardena, A Niroshan; Macmahon, Kenneth M; Espie, Colin A

    2014-02-01

    To investigate whether sleep restriction therapy (SRT) is associated with reduced objective total sleep time (TST), increased daytime somnolence, and impaired vigilance. Within-subject, noncontrolled treatment investigation. Sleep research laboratory. Sixteen patients [10 female, mean age = 47.1 (10.8) y] with well-defined psychophysiological insomnia (PI), reporting TST ≤ 6 h. Patients were treated with single-component SRT over a 4-w protocol, sleeping in the laboratory for 2 nights prior to treatment initiation and for 3 nights (SRT night 1, 8, 22) during the acute interventional phase. The psychomotor vigilance task (PVT) was completed at seven defined time points [day 0 (baseline), day 1,7,8,21,22 (acute treatment) and day 84 (3 mo)]. The Epworth Sleepiness Scale (ESS) was completed at baseline, w 1-4, and 3 mo. Subjective sleep outcomes and global insomnia severity significantly improved before and after SRT. There was, however, a robust decrease in PSG-defined TST during acute implementation of SRT, by an average of 91 min on night 1, 78 min on night 8, and 69 min on night 22, relative to baseline (P < 0.001; effect size range = 1.60-1.80). During SRT, PVT lapses were significantly increased from baseline (at three of five assessment points, all P < 0.05; effect size range = 0.69-0.78), returning to baseline levels by 3 mo (P = 0.43). A similar pattern was observed for RT, with RTs slowing during acute treatment (at four of five assessment points, all P < 0.05; effect size range = 0.57-0.89) and returning to pretreatment levels at 3 mo (P = 0.78). ESS scores were increased at w 1, 2, and 3 (relative to baseline; all P < 0.05); by 3 mo, sleepiness had returned to baseline (normative) levels (P = 0.65). For the first time we show that acute sleep restriction therapy is associated with reduced objective total sleep time, increased daytime sleepiness, and objective performance impairment. Our data have important implications for implementation guidelines around the safe and effective delivery of cognitive behavioral therapy for insomnia.

  3. Nucleation of actin polymerization by gelsolin.

    PubMed

    Ditsch, A; Wegner, A

    1994-08-15

    The time-course of assembly of actin with gelsolin was measured by the fluorescence increase of a fluorescent label covalently linked to actin. The actin concentrations ranged from values far below the critical concentration to values above the critical concentration of the pointed ends of actin filaments. If the concentration of actin was in the range of the critical monomer concentration (0.64 microM), the time-course of the concentration of actin assembled with gelsolin revealed a sigmoidal shape. At higher actin concentrations the time-course of association of actin with gelsolin approximated an exponential curve. The measured time-courses of assembly were quantitatively interpreted by kinetic rate equations. A poor fit was obtained if two actin molecules were assumed to bind to gelsolin to form a 1:2 gelsolin-actin complex and subsequently further actin molecules were assumed to polymerize onto the 1:2 gelsolin-actin complex toward the pointed end. A considerably better agreement between calculated and measured time-courses was achieved if additional creation of actin filaments by fast fragmentation of newly formed actin filaments by not yet consumed gelsolin was assumed to occur. This suggests that both polymerization of actin onto gelsolin and fragmentation of actin filaments contribute to formation of new actin filaments by gelsolin. Furthermore it could be demonstrated that below the critical monomer concentration appreciable amounts of actin are incorporated into gelsolin-actin oligomers.

  4. Method and apparatus for determining material structural integrity

    DOEpatents

    Pechersky, M.J.

    1994-01-01

    Disclosed are a nondestructive method and apparatus for determining the structural integrity of materials by combining laser vibrometry with damping analysis to determine the damping loss factor. The method comprises the steps of vibrating the area being tested over a known frequency range and measuring vibrational force and velocity vs time over the known frequency range. Vibrational velocity is preferably measured by a laser vibrometer. Measurement of the vibrational force depends on the vibration method: if an electromagnetic coil is used to vibrate a magnet secured to the area being tested, then the vibrational force is determined by the coil current. If a reciprocating transducer is used, the vibrational force is determined by a force gauge in the transducer. Using vibrational analysis, a plot of the drive point mobility of the material over the preselected frequency range is generated from the vibrational force and velocity data. Damping loss factor is derived from a plot of the drive point mobility over the preselected frequency range using the resonance dwell method and compared with a reference damping loss factor for structural integrity evaluation.

  5. Long and Short Range Correlations in Healthy and Pathologic Human Cardiac Prosses

    NASA Astrophysics Data System (ADS)

    Bunde, Armin

    2001-03-01

    Healthy sleep consists of several stages: deep sleep, light sleep and REM sleep. In this talk, recent work on the characterization of heart-rates in the three stages by long-range correlations is presented. Only in REM sleep, long-range correlations reminiscent to the wake phase occur, and the heart-rates show multifractal behaviour. In contrast, in non-REM phases, the heart-rates are uncorrelated above the typical breathing cycle time, pointing to a random regulation of the heartbeat during non-REM sleep. In deep sleep, the heart-rates show simple multifractal behaviour.

  6. The Pointing Self-calibration Algorithm for Aperture Synthesis Radio Telescopes

    NASA Astrophysics Data System (ADS)

    Bhatnagar, S.; Cornwell, T. J.

    2017-11-01

    This paper is concerned with algorithms for calibration of direction-dependent effects (DDE) in aperture synthesis radio telescopes (ASRT). After correction of direction-independent effects (DIE) using self-calibration, imaging performance can be limited by the imprecise knowledge of the forward gain of the elements in the array. In general, the forward gain pattern is directionally dependent and varies with time due to a number of reasons. Some factors, such as rotation of the primary beam with Parallactic Angle for Azimuth-Elevation mount antennas are known a priori. Some, such as antenna pointing errors and structural deformation/projection effects for aperture-array elements cannot be measured a priori. Thus, in addition to algorithms to correct for DD effects known a priori, algorithms to solve for DD gains are required for high dynamic range imaging. Here, we discuss a mathematical framework for antenna-based DDE calibration algorithms and show that this framework leads to computationally efficient optimal algorithms that scale well in a parallel computing environment. As an example of an antenna-based DD calibration algorithm, we demonstrate the Pointing SelfCal (PSC) algorithm to solve for the antenna pointing errors. Our analysis show that the sensitivity of modern ASRT is sufficient to solve for antenna pointing errors and other DD effects. We also discuss the use of the PSC algorithm in real-time calibration systems and extensions for antenna Shape SelfCal algorithm for real-time tracking and corrections for pointing offsets and changes in antenna shape.

  7. The Pointing Self-calibration Algorithm for Aperture Synthesis Radio Telescopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhatnagar, S.; Cornwell, T. J., E-mail: sbhatnag@nrao.edu

    This paper is concerned with algorithms for calibration of direction-dependent effects (DDE) in aperture synthesis radio telescopes (ASRT). After correction of direction-independent effects (DIE) using self-calibration, imaging performance can be limited by the imprecise knowledge of the forward gain of the elements in the array. In general, the forward gain pattern is directionally dependent and varies with time due to a number of reasons. Some factors, such as rotation of the primary beam with Parallactic Angle for Azimuth–Elevation mount antennas are known a priori. Some, such as antenna pointing errors and structural deformation/projection effects for aperture-array elements cannot be measuredmore » a priori. Thus, in addition to algorithms to correct for DD effects known a priori, algorithms to solve for DD gains are required for high dynamic range imaging. Here, we discuss a mathematical framework for antenna-based DDE calibration algorithms and show that this framework leads to computationally efficient optimal algorithms that scale well in a parallel computing environment. As an example of an antenna-based DD calibration algorithm, we demonstrate the Pointing SelfCal (PSC) algorithm to solve for the antenna pointing errors. Our analysis show that the sensitivity of modern ASRT is sufficient to solve for antenna pointing errors and other DD effects. We also discuss the use of the PSC algorithm in real-time calibration systems and extensions for antenna Shape SelfCal algorithm for real-time tracking and corrections for pointing offsets and changes in antenna shape.« less

  8. Organic-matter loading determines regime shifts and alternative states in an aquatic ecosystem

    PubMed Central

    Sirota, Jennie; Baiser, Benjamin; Gotelli, Nicholas J.; Ellison, Aaron M.

    2013-01-01

    Slow changes in underlying state variables can lead to “tipping points,” rapid transitions between alternative states (“regime shifts”) in a wide range of complex systems. Tipping points and regime shifts routinely are documented retrospectively in long time series of observational data. Experimental induction of tipping points and regime shifts is rare, but could lead to new methods for detecting impending tipping points and forestalling regime shifts. By using controlled additions of detrital organic matter (dried, ground arthropod prey), we experimentally induced a shift from aerobic to anaerobic states in a miniature aquatic ecosystem: the self-contained pools that form in leaves of the carnivorous northern pitcher plant, Sarracenia purpurea. In unfed controls, the concentration of dissolved oxygen ([O2]) in all replicates exhibited regular diurnal cycles associated with daytime photosynthesis and nocturnal plant respiration. In low prey-addition treatments, the regular diurnal cycles of [O2] were disrupted, but a regime shift was not detected. In high prey-addition treatments, the variance of the [O2] time series increased until the system tipped from an aerobic to an anaerobic state. In these treatments, replicate [O2] time series predictably crossed a tipping point at ∼45 h as [O2] was decoupled from diurnal cycles of photosynthesis and respiration. Increasing organic-matter loading led to predictable changes in [O2] dynamics, with high loading consistently driving the system past a well-defined tipping point. The Sarracenia microecosystem functions as a tractable experimental system in which to explore the forecasting and management of tipping points and alternative regimes. PMID:23613583

  9. Organic-matter loading determines regime shifts and alternative states in an aquatic ecosystem.

    PubMed

    Sirota, Jennie; Baiser, Benjamin; Gotelli, Nicholas J; Ellison, Aaron M

    2013-05-07

    Slow changes in underlying state variables can lead to "tipping points," rapid transitions between alternative states ("regime shifts") in a wide range of complex systems. Tipping points and regime shifts routinely are documented retrospectively in long time series of observational data. Experimental induction of tipping points and regime shifts is rare, but could lead to new methods for detecting impending tipping points and forestalling regime shifts. By using controlled additions of detrital organic matter (dried, ground arthropod prey), we experimentally induced a shift from aerobic to anaerobic states in a miniature aquatic ecosystem: the self-contained pools that form in leaves of the carnivorous northern pitcher plant, Sarracenia purpurea. In unfed controls, the concentration of dissolved oxygen ([O2]) in all replicates exhibited regular diurnal cycles associated with daytime photosynthesis and nocturnal plant respiration. In low prey-addition treatments, the regular diurnal cycles of [O2] were disrupted, but a regime shift was not detected. In high prey-addition treatments, the variance of the [O2] time series increased until the system tipped from an aerobic to an anaerobic state. In these treatments, replicate [O2] time series predictably crossed a tipping point at ~45 h as [O2] was decoupled from diurnal cycles of photosynthesis and respiration. Increasing organic-matter loading led to predictable changes in [O2] dynamics, with high loading consistently driving the system past a well-defined tipping point. The Sarracenia microecosystem functions as a tractable experimental system in which to explore the forecasting and management of tipping points and alternative regimes.

  10. Fast Quantum State Transfer and Entanglement Renormalization Using Long-Range Interactions.

    PubMed

    Eldredge, Zachary; Gong, Zhe-Xuan; Young, Jeremy T; Moosavian, Ali Hamed; Foss-Feig, Michael; Gorshkov, Alexey V

    2017-10-27

    In short-range interacting systems, the speed at which entanglement can be established between two separated points is limited by a constant Lieb-Robinson velocity. Long-range interacting systems are capable of faster entanglement generation, but the degree of the speedup possible is an open question. In this Letter, we present a protocol capable of transferring a quantum state across a distance L in d dimensions using long-range interactions with a strength bounded by 1/r^{α}. If α

  11. Fast Quantum State Transfer and Entanglement Renormalization Using Long-Range Interactions

    NASA Astrophysics Data System (ADS)

    Eldredge, Zachary; Gong, Zhe-Xuan; Young, Jeremy T.; Moosavian, Ali Hamed; Foss-Feig, Michael; Gorshkov, Alexey V.

    2017-10-01

    In short-range interacting systems, the speed at which entanglement can be established between two separated points is limited by a constant Lieb-Robinson velocity. Long-range interacting systems are capable of faster entanglement generation, but the degree of the speedup possible is an open question. In this Letter, we present a protocol capable of transferring a quantum state across a distance L in d dimensions using long-range interactions with a strength bounded by 1 /rα. If α

  12. Self-Exciting Point Process Modeling of Conversation Event Sequences

    NASA Astrophysics Data System (ADS)

    Masuda, Naoki; Takaguchi, Taro; Sato, Nobuo; Yano, Kazuo

    Self-exciting processes of Hawkes type have been used to model various phenomena including earthquakes, neural activities, and views of online videos. Studies of temporal networks have revealed that sequences of social interevent times for individuals are highly bursty. We examine some basic properties of event sequences generated by the Hawkes self-exciting process to show that it generates bursty interevent times for a wide parameter range. Then, we fit the model to the data of conversation sequences recorded in company offices in Japan. In this way, we can estimate relative magnitudes of the self excitement, its temporal decay, and the base event rate independent of the self excitation. These variables highly depend on individuals. We also point out that the Hawkes model has an important limitation that the correlation in the interevent times and the burstiness cannot be independently modulated.

  13. Solution of the advection-dispersion equation by a finite-volume eulerian-lagrangian local adjoint method

    USGS Publications Warehouse

    Healy, R.W.; Russell, T.F.

    1992-01-01

    A finite-volume Eulerian-Lagrangian local adjoint method for solution of the advection-dispersion equation is developed and discussed. The method is mass conservative and can solve advection-dominated ground-water solute-transport problems accurately and efficiently. An integrated finite-difference approach is used in the method. A key component of the method is that the integral representing the mass-storage term is evaluated numerically at the current time level. Integration points, and the mass associated with these points, are then forward tracked up to the next time level. The number of integration points required to reach a specified level of accuracy is problem dependent and increases as the sharpness of the simulated solute front increases. Integration points are generally equally spaced within each grid cell. For problems involving variable coefficients it has been found to be advantageous to include additional integration points at strategic locations in each well. These locations are determined by backtracking. Forward tracking of boundary fluxes by the method alleviates problems that are encountered in the backtracking approaches of most characteristic methods. A test problem is used to illustrate that the new method offers substantial advantages over other numerical methods for a wide range of problems.

  14. Influence of boiling point range of feedstock on properties of derived mesophase pitch

    NASA Astrophysics Data System (ADS)

    Yu, Ran; Liu, Dong; Lou, Bin; Chen, Qingtai; Zhang, Yadong; Li, Zhiheng

    2018-06-01

    The composition of raw material was optimized by vacuum distillation. The carbonization behavior of two kinds of raw material was followed by polarizing microscope, softening point, carbon yield and solubility. Two kinds of mesophase pitch have been monitored by X-ray diffraction (XRD), Fourier transform infrared spectrometer (FTIR), elemental analysis and 1H nuclear magnetic resonance (1H-NMR). The analysis results suggested that raw material B (15wt% of A was distillated out and the residue named B) could form large domain mesophase pitch earlier. The shortened heat treat time favored the retaining of alkyl group in mesophase pitch and reduced the softening point of masophase pitch.

  15. Obtaining Approximate Values of Exterior Orientation Elements of Multi-Intersection Images Using Particle Swarm Optimization

    NASA Astrophysics Data System (ADS)

    Li, X.; Li, S. W.

    2012-07-01

    In this paper, an efficient global optimization algorithm in the field of artificial intelligence, named Particle Swarm Optimization (PSO), is introduced into close range photogrammetric data processing. PSO can be applied to obtain the approximate values of exterior orientation elements under the condition that multi-intersection photography and a small portable plane control frame are used. PSO, put forward by an American social psychologist J. Kennedy and an electrical engineer R.C. Eberhart, is a stochastic global optimization method based on swarm intelligence, which was inspired by social behavior of bird flocking or fish schooling. The strategy of obtaining the approximate values of exterior orientation elements using PSO is as follows: in terms of image coordinate observed values and space coordinates of few control points, the equations of calculating the image coordinate residual errors can be given. The sum of absolute value of each image coordinate is minimized to be the objective function. The difference between image coordinate observed value and the image coordinate computed through collinear condition equation is defined as the image coordinate residual error. Firstly a gross area of exterior orientation elements is given, and then the adjustment of other parameters is made to get the particles fly in the gross area. After iterative computation for certain times, the satisfied approximate values of exterior orientation elements are obtained. By doing so, the procedures like positioning and measuring space control points in close range photogrammetry can be avoided. Obviously, this method can improve the surveying efficiency greatly and at the same time can decrease the surveying cost. And during such a process, only one small portable control frame with a couple of control points is employed, and there are no strict requirements for the space distribution of control points. In order to verify the effectiveness of this algorithm, two experiments are carried out. In the first experiment, images of a standard grid board are taken according to multi-intersection photography using digital camera. Three points or six points which are located on the left-down corner of the standard grid are regarded as control points respectively, and the exterior orientation elements of each image are computed through PSO, and compared with these elements computed through bundle adjustment. In the second experiment, the exterior orientation elements obtained from the first experiment are used as approximate values in bundle adjustment and then the space coordinates of other grid points on the board can be computed. The coordinate difference of grid points between these computed space coordinates and their known coordinates can be used to compute the accuracy. The point accuracy computed in above experiments are ±0.76mm and ±0.43mm respectively. The above experiments prove the effectiveness of PSO used in close range photogrammetry to compute approximate values of exterior orientation elements, and the algorithm can meet the requirement of higher accuracy. In short, PSO can get better results in a faster, cheaper way compared with other surveying methods in close range photogrammetry.

  16. Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1995-01-01

    The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

  17. Laser Surveying

    NASA Technical Reports Server (NTRS)

    1978-01-01

    NASA technology has produced a laser-aided system for surveying land boundaries in difficult terrain. It does the job more accurately than conventional methods, takes only one-third the time normally required, and is considerably less expensive. In surveying to mark property boundaries, the objective is to establish an accurate heading between two "corner" points. This is conventionally accomplished by erecting a "range pole" at one point and sighting it from the other point through an instrument called a theodolite. But how do you take a heading between two points which are not visible to each other, for instance, when tall trees, hills or other obstacles obstruct the line of sight? That was the problem confronting the U.S. Department of Agriculture's Forest Service. The Forest Service manages 187 million acres of land in 44 states and Puerto Rico. Unfortunately, National Forest System lands are not contiguous but intermingled in complex patterns with privately-owned land. In recent years much of the private land has been undergoing development for purposes ranging from timber harvesting to vacation resorts. There is a need for precise boundary definition so that both private owners and the Forest Service can manage their properties with confidence that they are not trespassing on the other's land.

  18. A microwave resonance dew-point hygrometer

    NASA Astrophysics Data System (ADS)

    Underwood, R. J.; Cuccaro, R.; Bell, S.; Gavioso, R. M.; Madonna Ripa, D.; Stevens, M.; de Podesta, M.

    2012-08-01

    We report the first measurements of a quasi-spherical microwave resonator used as a dew-point hygrometer. In conventional dew-point hygrometers, the condensation of water from humid gas flowing over a mirror is detected optically, and the mirror surface is then temperature-controlled to yield a stable condensed layer. In our experiments we flowed moist air from a humidity generator through a quasi-spherical resonator and detected the onset of condensation by measuring the frequency ratio of selected microwave modes. We verified the basic operation of the device over the dew-point range 9.5-13.5 °C by comparison with calibrated chilled-mirror hygrometers. These tests indicate that the microwave method may allow a quantitative estimation of the volume and thickness of the water layer which is condensed on the inner surface of the resonator. The experiments reported here are preliminary due to the limited time available for the work, but show the potential of the method for detecting not only water but a variety of other liquid or solid condensates. The robust all-metal construction should make the device appropriate for use in industrial applications over a wide range of temperatures and pressures.

  19. The Evaluation of Small Arms Effectiveness Criteria, Volume I

    DTIC Science & Technology

    1975-05-01

    UNCLASSIFIED AD NUMBER ADB004382 NEW LIMITATION CHANGE TO Approved for public release, distribution unlimited FROM Distribution authorized to U.S...aimedSand pointed fire E-14 E-4 Frequency distribution of sizes of M16 and BAR bursts of automatic fire E-16 SE-5 Percent of times each range bracket...defense range F-10 F-4 Weapon-signature simuilator F-15 1 F-5 Target components in armored target box F-17 F-6 Portable round counter for the M16 rifle

  20. Variability of United States Online Rehabilitation Protocols for Proximal Hamstring Tendon Repair.

    PubMed

    Lightsey, Harry M; Kantrowitz, David E; Swindell, Hasani W; Trofa, David P; Ahmad, Christopher S; Lynch, T Sean

    2018-02-01

    The optimal postoperative rehabilitation protocol following repair of complete proximal hamstring tendon ruptures is the subject of ongoing investigation, with a need for more standardized regimens and evidence-based modalities. To assess the variability across proximal hamstring tendon repair rehabilitation protocols published online by United States (US) orthopaedic teaching programs. Cross-sectional study. Online proximal hamstring physical therapy protocols from US academic orthopaedic programs were reviewed. A web-based search using the search term complete proximal hamstring repair rehabilitation protocol provided an additional 14 protocols. A comprehensive scoring rubric was developed after review of all protocols and was used to assess each protocol for both the presence of various rehabilitation components and the point at which those components were introduced. Of 50 rehabilitation protocols identified, 35 satisfied inclusion criteria and were analyzed. Twenty-five protocols (71%) recommended immediate postoperative bracing: 12 (34%) prescribed knee bracing, 8 (23%) prescribed hip bracing, and 5 (14%) did not specify the type of brace recommended. Fourteen protocols (40%) advised immediate nonweightbearing with crutches, while 16 protocols (46%) permitted immediate toe-touch weightbearing. Advancement to full weightbearing was allowed at a mean of 7.1 weeks (range, 4-12 weeks). Most protocols (80%) recommended gentle knee and hip passive range of motion and active range of motion, starting at a mean 1.4 weeks (range, 0-3 weeks) and 4.0 weeks (range, 0-6 weeks), respectively. However, only 6 protocols (17%) provided specific time points to initiate full hip and knee range of motion: a mean 8.0 weeks (range, 4-12 weeks) and 7.8 weeks (range, 0-12 weeks), respectively. Considerable variability was noted in the inclusion and timing of strengthening, stretching, proprioception, and cardiovascular exercises. Fifteen protocols (43%) required completion of specific return-to-sport criteria before resuming training. Marked variability is found in both the composition and timing of rehabilitation components across the various complete proximal hamstring repair rehabilitation protocols published online. This finding mirrors the variability of proposed rehabilitation protocols in the professional literature and represents an opportunity to improve patient care.

  1. Guidance, Navigation, and Control Performance for the GOES-R Spacecraft

    NASA Technical Reports Server (NTRS)

    Chapel, Jim D.; Stancliffe, Devin; Bevacqua, Tim; Winkler, Stephen; Clapp, Brian; Rood, Tim; Gaylor, David; Freesland, Douglas C.; Krimchansky, Alexander

    2014-01-01

    The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites, scheduled for delivery in late 2015 and launch in early 2016. Relative to the current generation of GOES satellites, GOES-R represents a dramatic increase in Earth and solar weather observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands for Earth observations. GOES-R will also provide unprecedented availability, with less than 120 minutes per year of lost observation time. The Guidance Navigation & Control (GN&C) design requirements to achieve these expanded capabilities are extremely demanding. This paper first presents the pointing control, pointing stability, attitude knowledge, and orbit knowledge requirements necessary to realize the ambitious Image Navigation and Registration (INR) objectives of GOES-R. Because the GOES-R suite of instruments is sensitive to disturbances over a broad spectral range, a high fidelity simulation of the vehicle has been created with modal content over 500 Hz to assess the pointing stability requirements. Simulation results are presented showing acceleration, shock response spectrum (SRS), and line of sight responses for various disturbances from 0 Hz to 512 Hz. These disturbances include gimbal motion, reaction wheel disturbances, thruster firings for station keeping and momentum management, and internal instrument disturbances. Simulation results demonstrate excellent performance relative to the pointing and pointing stability requirements, with line of sight jitter of the isolated instrument platform of approximately 1 micro-rad. Low frequency motion of the isolated instrument platform is internally compensated within the primary instrument. Attitude knowledge and rate are provided directly to the instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The allowable IRE ranges from 1 to 18.5 micro-rad, depending upon the time window of interest. The final piece of the INR performance is orbit knowledge. Extremely accurate orbital position is achieved by GPS navigation at Geosynchronous Earth Orbit (GEO). Performance results are shown demonstrating compliance with the 50 to 75 m orbit position accuracy requirements of GOES-R, including during station-keeping and momentum management maneuvers. As shown in this paper, the GN&C performance for the GOES-R series of spacecraft supports the challenging mission objectives of the next generation GEO Earth-observation satellites.

  2. Objective evaluation of female feet and leg joint conformation at time of selection and post first parity in swine.

    PubMed

    Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J

    2018-06-09

    Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.

  3. [Application of damage control concept in severe limbs fractures combining with multiple trauma].

    PubMed

    Bayin, Er-gu-le; Jin, Hong-bing; Li, Ming

    2015-09-01

    To discuss the application and clinical effect of damage control concept in the treatment of severe limbs fractures combining with multiple trauma. From July 2009 to July 2012, 30 patients with severe limbs fractures combining with multiple trauma were treated with the damage control concept, included 20 males and 10 females with an average age of (34.03 ± 12.81) years old ranging from 20 to 60 years old; the ISS averaged (35.00 ± 12.81) points (ranged from 26 to 54 points). And the control group also contained 30 patients with severe limbs fractures combining with multiple trauma treated by the traditional operation from June 2006 to June 2009, there were 23 males and 7 females with an average age of (34.23 ± 11.04) years old ranging from 18 to 65 years old. The ISS averaged (35.56 ± 11.04) points (ranged from 26 to 51 points). The age, gender, ISS, Gustilo classification, operation time, intraoperative blood loss, blood transfusion,postoperative complications and mortality rate were observed and compared. In the damage control concept group,there were 28 cases surviving and 2 cases (6.7%) death; 6 cases of postoperative complication included 2 cases of adult respiratory distress syndrome, 1 case of multiple organ failure, 1 case of disseminated intravascular coagulation and 2 cases of wound infection. In the control group, there were 22 cases surviving and 8 cases death(26.7%); 13 cases of postoperative complication included 4 cases of adult respiratory distress syndrome,2 cases of multiple organ failure, 2 cases of disseminated intravascular coagulation and 3 cases of wound infection. There were no statistically significant differences between two groups in age, gender, ISS, Gustilo classfication and complication (P > 0.05), however there were statistically significant differences in mortality rate, operation time, blodd loss, blodd transfusion between two groups (P < 0.05). Damage control concept is used to treat severe limbs fractures combining with multiple trauma which has the rapid and effective therapy, can improve survival rate and reduce complication.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, K.A.; Atkinson, P.F.; Hammond, E.C.,JR.

    Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. The results indicate that film batch differences, temperature, and aging play an important rolemore » in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.« less

  5. Performance Characteristics of a New LSO PET/CT Scanner With Extended Axial Field-of-View and PSF Reconstruction

    NASA Astrophysics Data System (ADS)

    Jakoby, Bjoern W.; Bercier, Yanic; Watson, Charles C.; Bendriem, Bernard; Townsend, David W.

    2009-06-01

    A new combined lutetium oxyorthosilicate (LSO) PET/CT scanner with an extended axial field-of-view (FOV) of 21.8 cm has been developed (Biograph TruePoint PET/CT with TrueV; Siemens Molecular Imaging) and introduced into clinical practice. The scanner includes the recently announced point spread function (PSF) reconstruction algorithm. The PET components incorporate four rings of 48 detector blocks, 5.4 cm times 5.4 cm in cross-section. Each block comprises a 13 times 13 matrix of 4 times 4 times 20 mm3 elements. Data are acquired with a 4.5 ns coincidence time window and an energy window of 425-650 keV. The physical performance of the new scanner has been evaluated according to the recently revised National Electrical Manufacturers Association (NEMA) NU 2-2007 standard and the results have been compared with a previous PET/CT design that incorporates three rings of block detectors with an axial coverage of 16.2 cm (Biograph TruePoint PET/CT; Siemens Molecular Imaging). In addition to the phantom measurements, patient Noise Equivalent Count Rates (NECRs) have been estimated for a range of patients with different body weights (42-154 kg). The average spatial resolution is the same for both scanners: 4.4 mm (FWHM) and 5.0 mm (FWHM) at 1 cm and 10 cm respectively from the center of the transverse FOV. The scatter fractions of the Biograph TruePoint and Biograph TruePoint TrueV are comparable at 32%. Compared to the three ring design, the system sensitivity and peak NECR with smoothed randoms correction (1R) increase by 82% and 73%, respectively. The increase in sensitivity from the extended axial coverage of the Biograph TruePoint PET/CT with TrueV should allow a decrease in either scan time or injected dose without compromising diagnostic image quality. The contrast improvement with the PSF reconstruction potentially offers enhanced detectability for small lesions.

  6. Clinical and radiological mid-term results of the thrust plate prosthesis

    PubMed Central

    v.d. Daele, R.; Simon, U.; Goetze, C.

    2009-01-01

    The purpose of this study was to perform an objective clinical and radiological assessment of the thrust plate prosthesis (TPP). Fifty-three prostheses were evaluated clinically using the Harris hip score (HHS), visual analog scale (VAS), and radiographically before surgery, at the time of discharge, and postoperatively after on average of 8.09 (range 4.61–9.93) years. The average HHS significantly (p ≤ 0.05) improved from 48 (range 18–77) points to 95 (range 46–100) points. The VAS revealed significant (p ≤ 0.05) reduction of pain at rest and under load. Radiographic analysis showed a considerable potential for osteolysis under the thrust plate. Sixteen prostheses revealed signs of radiolucent zones. In general, there was a good clinical outcome with no major limitations in function. Radiographic changes under the thrust plate indicate an adaptation processes resulting from changed biomechanics. This study suggests that the TPP could be a good alternative in total hip replacement in younger patients. PMID:19184010

  7. Models of the quiet and active solar atmosphere from Harvard OSO data.

    NASA Technical Reports Server (NTRS)

    Noyes, R. W.

    1971-01-01

    Review of some Harvard Observatory programs aimed at defining the physical conditions in quiet and active solar regions on the basis of data obtained from the OSO-IV and OSO-VI spacecraft. The spectral range covered is from 300 A to 1400 A. This spectral range consists of emission lines and continua from abundant elements such as hydrogen, helium, carbon, nitrogen, oxygen, silicon, magnesium, aluminum, neon, iron, and calcium in various ionization states ranging from neutral to 15 times ionized. The structure is discussed of the quiet solar atmosphere as deduced from center-to-limb behavior of spectral lines and continua formed in the chromosphere and corona. In reviewing investigations of solar active regions, it is shown that the structure of these regions varies in a complicated manner from point to point. The local structure is influenced by factors such as the magnetic field configuration within the active region and the age or evolutionary state of the region.

  8. Documenting a Complex Modern Heritage Building Using Multi Image Close Range Photogrammetry and 3d Laser Scanned Point Clouds

    NASA Astrophysics Data System (ADS)

    Vianna Baptista, M. L.

    2013-07-01

    Integrating different technologies and expertises help fill gaps when optimizing documentation of complex buildings. Described below is the process used in the first part of a restoration project, the architectural survey of Theatre Guaira Cultural Centre in Curitiba, Brazil. To diminish time on fieldwork, the two-person-field-survey team had to juggle, during three days, the continuous artistic activities and performers' intense schedule. Both technologies (high definition laser scanning and close-range photogrammetry) were used to record all details in the least amount of time without disturbing the artists' rehearsals and performances. Laser Scanning was ideal to record the monumental stage structure with all of its existing platforms, light fixtures, scenery walls and curtains. Although scanned with high-definition, parts of the exterior façades were also recorded using Close Range Photogrammetry. Tiny cracks on the marble plaques and mosaic tiles, not visible in the point clouds, were then able to be precisely documented in order to create the exterior façades textures and damages mapping drawings. The combination of technologies and the expertise of service providers, knowing how and what to document, and what to deliver to the client, enabled maximum benefits to the following restoration project.

  9. Landscape Change Detected Over A 60 Year Period In The Arctic National Wildlife Refuge, Alaska, Using High Resolution Aerial Photographs And Satellite Images

    NASA Astrophysics Data System (ADS)

    Jorgenson, J. C.; Jorgenson, M. T.; Boldenow, M.; Orndahl, K. M.

    2016-12-01

    We documented landscape change over a 60 year period in the Arctic National Wildlife Refuge in northeastern Alaska using aerial photographs and satellite images. We used a stratified random sample to allow inference to the whole refuge (78,050 km2), with five random sites in each of seven ecoregions. Each site (2 km2) had a systematic grid of 100 points for a total of 3500 points. We chose study sites in the overlap area covered by acceptable imagery in three time periods: aerial photographs from 1947 - 1955 and 1978 - 1988, Quick Bird and IKONOS satellite images from 2000 - 2007.At each point a 10 meter radius circle was visually evaluated in ARC-MAP for each time period for vegetation type, disturbance, presence of ice wedge polygon microtopography and surface water. A landscape change category was assigned to each point based on differences detected between the three periods. Change types were assigned for time interval 1, interval 2 and overall. Additional explanatory variables included elevation, slope, aspect, geology, physiography and temperature. Overall, 23% of points changed over the study period. Fire was the most common change agent, affecting 28% of the Boreal Forest points. The next most common change was degradation of soil ice wedges (thermokarst), detected at 12% of the points on the North Slope Tundra. The other most common changes included increase in cover of trees or shrubs (7% of Boreal Forest and Brooks Range points) and erosion or deposition on river floodplains and at the Beaufort Sea coast. Changes on the North Slope Tundra tended to be related to landscape wetting, mainly thermokarst. Changes in the Boreal Forest tended to involve landscape drying, including fire, reduced area of lakes and tree increase on wet sites. The second time interval coincided with a shift towards a warmer climate and had greater change in several categories including thermokarst, lake changes and tree and shrub increase.

  10. Numerical analysis of transient fields near thin-wire antennas and scatterers

    NASA Astrophysics Data System (ADS)

    Landt, J. A.

    1981-11-01

    Under the premise that `accelerated charge radiates,' one would expect radiation on wire structures to occur from driving points, ends of wires, bends in wires, or locations of lumped loading. Here, this premise is investigated in a series of numerical experiments. The numerical procedure is based on a moment-method solution of a thin-wire time-domain electric-field integral equation. The fields in the vicinity of wire structures are calculated for short impulsive-type excitations, and are viewed in a series of time sequences or snapshots. For these excitations, the fields are spatially limited in the radial dimension, and expand in spheres centered about points of radiation. These centers of radiation coincide with the above list of possible source regions. Time retardation permits these observations to be made clearly in the time domain, similar to time-range gating. In addition to providing insight into transient radiation processes, these studies show that the direction of energy flow is not always defined by Poynting's vector near wire structures.

  11. Fermat's least-time principle and the embedded transparent lens

    NASA Astrophysics Data System (ADS)

    Kantowski, R.; Chen, B.; Dai, X.

    2013-10-01

    We present a simplified version of the lowest-order embedded point mass gravitational lens theory and then make the extension of this theory to any embedded transparent lens. Embedding a lens effectively reduces the gravitational potential’s range, i.e., partially shields the lensing potential because the lens mass is made a contributor to the mean mass density of the Universe and not simply superimposed upon it. We give the time-delay function for the embedded point mass lens from which we can derive the simplified lens equation by applying Fermat’s least-time principle. Even though rigorous derivations are only made for the point mass in a flat background, the generalization of the lens equation to lowest order for any distributed lens in any homogeneous background is obvious. We find from this simplified theory that embedding can introduce corrections above the few percent level in weak lensing shears caused by large clusters but only at large impacts. The potential part of the time delay is also affected in strong lensing at the few percent level. Additionally we again confirm that the presence of a cosmological constant alters the gravitational deflection of passing photons.

  12. Foliage penetration by using 4-D point cloud data

    NASA Astrophysics Data System (ADS)

    Méndez Rodríguez, Javier; Sánchez-Reyes, Pedro J.; Cruz-Rivera, Sol M.

    2012-06-01

    Real-time awareness and rapid target detection are critical for the success of military missions. New technologies capable of detecting targets concealed in forest areas are needed in order to track and identify possible threats. Currently, LAser Detection And Ranging (LADAR) systems are capable of detecting obscured targets; however, tracking capabilities are severely limited. Now, a new LADAR-derived technology is under development to generate 4-D datasets (3-D video in a point cloud format). As such, there is a new need for algorithms that are able to process data in real time. We propose an algorithm capable of removing vegetation and other objects that may obfuscate concealed targets in a real 3-D environment. The algorithm is based on wavelets and can be used as a pre-processing step in a target recognition algorithm. Applications of the algorithm in a real-time 3-D system could help make pilots aware of high risk hidden targets such as tanks and weapons, among others. We will be using a 4-D simulated point cloud data to demonstrate the capabilities of our algorithm.

  13. Evaluation of satisfaction in an extracurricular enrichment program for high-intellectual ability participants.

    PubMed

    Sastre I Riba, Sylvia; Fonseca-Pedrero, Eduardo; Santarén-Rosell, Marta; Urraca-Martínez, María Luz

    2015-01-01

    The objective of this study was to evaluate the satisfaction of an extracurricular enrichment program of the cognitive and personal management of participants with high intellectual ability. At the first time point, the sample consisted of n= 38 participants, and n= 20 parents; n= 48 participants at the second time point; and n= 60 participants at the third time point. The Satisfaction Questionnaire (CSA in Spanish), both for students (CSA-S) and for parents (CSA-P), was constructed. The CSA-S scores showed adequate psychometric properties. Exploratory factor analysis yielded a unidimensional structure. Cronbach’s alpha ranged between 85 and .86. Test-retest reliability was 0.45 (p<.05). The generalizability coefficient was .98. A high percentage of the sample was satisfied with the program, perceived improvements in cognitive and emotional management, motivation and interest in learning, and in the frequency and quality of their interpersonal relationships. The evaluation of educational programs is necessary in order to determine the efficacy and the effects of their implementation on the participants’ personal and intellectual management.

  14. Analytic expressions for perturbations and partial derivatives of range and range rate of a spacecraft with respect to the coefficient of the second harmonic

    NASA Technical Reports Server (NTRS)

    Georgevic, R. M.

    1973-01-01

    Closed-form analytic expressions for the time variations of instantaneous orbital parameters and of the topocentric range and range rate of a spacecraft moving in the gravitational field of an oblate large body are derived using a first-order variation of parameters technique. In addition, the closed-form analytic expressions for the partial derivatives of the topocentric range and range rate are obtained, with respect to the coefficient of the second harmonic of the potential of the central body (J sub 2). The results are applied to the motion of a point-mass spacecraft moving in the orbit around the equatorially elliptic, oblate sun, with J sub 2 approximately equal to .000027.

  15. The effect of vapor polarity and boiling point on breakthrough for binary mixtures on respirator carbon.

    PubMed

    Robbins, C A; Breysse, P N

    1996-08-01

    This research evaluated the effect of the polarity of a second vapor on the adsorption of a polar and a nonpolar vapor using the Wheeler model. To examine the effect of polarity, it was also necessary to observe the effect of component boiling point. The 1% breakthrough time (1% tb), kinetic adsorption capacity (W(e)), and rate constant (kv) of the Wheeler model were determined for vapor challenges on carbon beds for both p-xylene and pyrrole (referred to as test vapors) individually, and in equimolar binary mixtures with the polar and nonpolar vapors toluene, p-fluorotoluene, o-dichlorobenzene, and p-dichlorobenzene (referred to as probe vapors). Probe vapor polarity (0 to 2.5 Debye) did not systematically alter the 1% tb, W(e), or kv of the test vapors. The 1% tb and W(e) for test vapors in binary mixtures can be estimated reasonably well, using the Wheeler model, from single-vapor data (1% tb +/- 30%, W(e) +/- 20%). The test vapor 1% tb depended mainly on total vapor concentration in both single and binary systems. W(e) was proportional to test vapor fractional molar concentration (mole fraction) in mixtures. The kv for p-xylene was significantly different (p < or = 0.001) when compared according to probe boiling point; however, these differences were apparently of limited importance in estimating 1% tb for the range of boiling points tested (111 to 180 degrees C). Although the polarity and boiling point of chemicals in the range tested are not practically important in predicting 1% tb with the Wheeler model, an effect due to probe boiling point is suggested, and tests with chemicals of more widely ranging boiling point are warranted. Since the 1% tb, and thus, respirator service life, depends mainly on total vapor concentration, these data underscore the importance of taking into account the presence of other vapors when estimating respirator service life for a vapor in a mixture.

  16. The effect of timing of manipulation under anesthesia to improve range of motion and functional outcomes following total knee arthroplasty.

    PubMed

    Issa, Kimona; Banerjee, Samik; Kester, Mark A; Khanuja, Harpal S; Delanois, Ronald E; Mont, Michael A

    2014-08-20

    Manipulation under anesthesia has been reported to improve range of motion when other rehabilitative efforts fail to obtain adequate motion after total knee arthroplasty. The purpose of this study was to evaluate the effects of the timing of the manipulation on knee range of motion and clinical outcomes. All 2128 total knee arthroplasties performed at our institution from 2005 to 2011 were reviewed to determine the number of patients who had undergone manipulation under anesthesia. A total of 144 manipulations in eighty-eight women and forty-five men were reviewed. Manipulations under anesthesia that were performed within the first twelve weeks after total knee arthroplasty were considered early and those after that period were considered late. Patients were further substratified according to the timing of the manipulation: Group I included those who had the manipulation within six weeks; Group II, at seven to twelve weeks; Group III, at thirteen to twenty-six weeks; and Group IV, after twenty-six weeks. Outcomes evaluated included gains in flexion and final range of motion, and Knee Society objective and function scores between early and late manipulation, using various adjusted multivariable regression models and at a mean follow-up of fifty-one months (range, twelve to eighty-one months). Mediation analysis was used to investigate whether gains in range of motion from the manipulations under anesthesia alone had mediated the effect between the timing of the manipulation and the clinical outcomes. Patients who underwent early manipulation had a significantly higher mean gain in flexion (36.5° versus 17°), higher final range of motion (119° versus 95°), and higher Knee Society objective (89 versus 84 points) and function scores (88 versus 83 points) than those who had late manipulation under anesthesia. There were no significant differences in the outcomes of Groups I and II. Manipulations after twenty-six weeks resulted in unsatisfactory clinical outcomes. Multivariable regression analyses confirmed significantly better clinical outcomes with early manipulation. Mediation analysis showed that the timing of manipulation independently had significantly contributed to the outcomes. Orthopaedic surgeons should have a low threshold for performing early manipulations with the patient under anesthesia within twelve weeks after an arthroplasty, to achieve higher knee range of motion and improved clinical outcomes. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  17. A Statistical Guide to the Design of Deep Mutational Scanning Experiments

    PubMed Central

    Matuszewski, Sebastian; Hildebrandt, Marcel E.; Ghenu, Ana-Hermina; Jensen, Jeffrey D.; Bank, Claudia

    2016-01-01

    The characterization of the distribution of mutational effects is a key goal in evolutionary biology. Recently developed deep-sequencing approaches allow for accurate and simultaneous estimation of the fitness effects of hundreds of engineered mutations by monitoring their relative abundance across time points in a single bulk competition. Naturally, the achievable resolution of the estimated fitness effects depends on the specific experimental setup, the organism and type of mutations studied, and the sequencing technology utilized, among other factors. By means of analytical approximations and simulations, we provide guidelines for optimizing time-sampled deep-sequencing bulk competition experiments, focusing on the number of mutants, the sequencing depth, and the number of sampled time points. Our analytical results show that sampling more time points together with extending the duration of the experiment improves the achievable precision disproportionately compared with increasing the sequencing depth or reducing the number of competing mutants. Even if the duration of the experiment is fixed, sampling more time points and clustering these at the beginning and the end of the experiment increase experimental power and allow for efficient and precise assessment of the entire range of selection coefficients. Finally, we provide a formula for calculating the 95%-confidence interval for the measurement error estimate, which we implement as an interactive web tool. This allows for quantification of the maximum expected a priori precision of the experimental setup, as well as for a statistical threshold for determining deviations from neutrality for specific selection coefficient estimates. PMID:27412710

  18. Wall shear stress fixed points in cardiovascular fluid mechanics.

    PubMed

    Arzani, Amirhossein; Shadden, Shawn C

    2018-05-17

    Complex blood flow in large arteries creates rich wall shear stress (WSS) vectorial features. WSS acts as a link between blood flow dynamics and the biology of various cardiovascular diseases. WSS has been of great interest in a wide range of studies and has been the most popular measure to correlate blood flow to cardiovascular disease. Recent studies have emphasized different vectorial features of WSS. However, fixed points in the WSS vector field have not received much attention. A WSS fixed point is a point on the vessel wall where the WSS vector vanishes. In this article, WSS fixed points are classified and the aspects by which they could influence cardiovascular disease are reviewed. First, the connection between WSS fixed points and the flow topology away from the vessel wall is discussed. Second, the potential role of time-averaged WSS fixed points in biochemical mass transport is demonstrated using the recent concept of Lagrangian WSS structures. Finally, simple measures are proposed to quantify the exposure of the endothelial cells to WSS fixed points. Examples from various arterial flow applications are demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Multi-Level Information Systems. AIR Forum Paper 1978.

    ERIC Educational Resources Information Center

    Jones, Leighton D.; Trautman, DeForest L.

    To support informational needs of day-to-day and long-range decision-making, many universities have developed their own data collection devices and institutional reporting systems. Often these models only represent a single point in time and do not effectively support needs at college and departmental levels. This paper identifies some of the more…

  20. Pulse Voltammetry in Single Cells Using Platinum Microelectrodes

    DTIC Science & Technology

    1991-11-22

    E. and the range for Ed in multiple pulse voltammetry can be chosen from examination of voltammograms obtained by cyclic voltammetry or lin-ir sweep ... voltametry [3,13]. As pointed out by Sinru et al. [14) the potential and time of each pulse has a direct effect on the nature of the voltammetry

  1. Thermal weapon sights with integrated fire control computers: algorithms and experiences

    NASA Astrophysics Data System (ADS)

    Rothe, Hendrik; Graswald, Markus; Breiter, Rainer

    2008-04-01

    The HuntIR long range thermal weapon sight of AIM is deployed in various out of area missions since 2004 as a part of the German Future Infantryman system (IdZ). In 2007 AIM fielded RangIR as upgrade with integrated laser Range finder (LRF), digital magnetic compass (DMC) and fire control unit (FCU). RangIR fills the capability gaps of day/night fire control for grenade machine guns (GMG) and the enhanced system of the IdZ. Due to proven expertise and proprietary methods in fire control, fast access to military trials for optimisation loops and similar hardware platforms, AIM and the University of the Federal Armed Forces Hamburg (HSU) decided to team for the development of suitable fire control algorithms. The pronounced ballistic trajectory of the 40mm GMG requires most accurate FCU-solutions specifically for air burst ammunition (ABM) and is most sensitive to faint effects like levelling or firing up/downhill. This weapon was therefore selected to validate the quality of the FCU hard- and software under relevant military conditions. For exterior ballistics the modified point mass model according to STANAG 4355 is used. The differential equations of motions are solved numerically, the two point boundary value problem is solved iteratively. Computing time varies according to the precision needed and is typical in the range from 0.1 - 0.5 seconds. RangIR provided outstanding hit accuracy including ABM fuze timing in various trials of the German Army and allied partners in 2007 and is now ready for series production. This paper deals mainly with the fundamentals of the fire control algorithms and shows how to implement them in combination with any DSP-equipped thermal weapon sights (TWS) in a variety of light supporting weapon systems.

  2. Performances of different global positioning system devices for time-location tracking in air pollution epidemiological studies.

    PubMed

    Wu, Jun; Jiang, Chengsheng; Liu, Zhen; Houston, Douglas; Jaimes, Guillermo; McConnell, Rob

    2010-11-23

    People's time-location patterns are important in air pollution exposure assessment because pollution levels may vary considerably by location. A growing number of studies are using global positioning systems (GPS) to track people's time-location patterns. Many portable GPS units that archive location are commercially available at a cost that makes their use feasible for epidemiological studies. We evaluated the performance of five portable GPS data loggers and two GPS cell phones by examining positional accuracy in typical locations (indoor, outdoor, in-vehicle) and factors that influence satellite reception (building material, building type), acquisition time (cold and warm start), battery life, and adequacy of memory for data storage. We examined stationary locations (eg, indoor, outdoor) and mobile environments (eg, walking, traveling by vehicle or bus) and compared GPS locations to highly-resolved US Geological Survey (USGS) and Digital Orthophoto Quarter Quadrangle (DOQQ) maps. The battery life of our tested instruments ranged from <9 hours to 48 hours. The acquisition of location time after startup ranged from a few seconds to >20 minutes and varied significantly by building structure type and by cold or warm start. No GPS device was found to have consistently superior performance with regard to spatial accuracy and signal loss. At fixed outdoor locations, 65%-95% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices. At fixed indoor locations, 50%-80% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices except one. Most of the GPS devices performed well during commuting on a freeway, with >80% of points within 10-m of the DOQQ route, but the performance was significantly impacted by surrounding structures on surface streets in highly urbanized areas. All the tested GPS devices had limitations, but we identified several devices which showed promising performance for tracking subjects' time location patterns in epidemiological studies.

  3. Performances of Different Global Positioning System Devices for Time-Location Tracking in Air Pollution Epidemiological Studies

    PubMed Central

    Wu, Jun; Jiang, Chengsheng; Liu, Zhen; Houston, Douglas; Jaimes, Guillermo; McConnell, Rob

    2010-01-01

    Background: People’s time-location patterns are important in air pollution exposure assessment because pollution levels may vary considerably by location. A growing number of studies are using global positioning systems (GPS) to track people’s time-location patterns. Many portable GPS units that archive location are commercially available at a cost that makes their use feasible for epidemiological studies. Methods: We evaluated the performance of five portable GPS data loggers and two GPS cell phones by examining positional accuracy in typical locations (indoor, outdoor, in-vehicle) and factors that influence satellite reception (building material, building type), acquisition time (cold and warm start), battery life, and adequacy of memory for data storage. We examined stationary locations (eg, indoor, outdoor) and mobile environments (eg, walking, traveling by vehicle or bus) and compared GPS locations to highly-resolved US Geological Survey (USGS) and Digital Orthophoto Quarter Quadrangle (DOQQ) maps. Results: The battery life of our tested instruments ranged from <9 hours to 48 hours. The acquisition of location time after startup ranged from a few seconds to >20 minutes and varied significantly by building structure type and by cold or warm start. No GPS device was found to have consistently superior performance with regard to spatial accuracy and signal loss. At fixed outdoor locations, 65%–95% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices. At fixed indoor locations, 50%–80% of GPS points fell within 20-m of the corresponding DOQQ locations for all the devices except one. Most of the GPS devices performed well during commuting on a freeway, with >80% of points within 10-m of the DOQQ route, but the performance was significantly impacted by surrounding structures on surface streets in highly urbanized areas. Conclusions: All the tested GPS devices had limitations, but we identified several devices which showed promising performance for tracking subjects’ time location patterns in epidemiological studies. PMID:21151593

  4. Critical coupling and coherent perfect absorption for ranges of energies due to a complex gain and loss symmetric system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasan, Mohammad, E-mail: mohammadhasan786@gmail.com; Ghatak, Ananya, E-mail: gananya04@gmail.com; Mandal, Bhabani Prasad, E-mail: bhabani.mandal@gmail.com

    2014-05-15

    We consider a non-Hermitian medium with a gain and loss symmetric, exponentially damped potential distribution to demonstrate different scattering features analytically. The condition for critical coupling (CC) for unidirectional wave and coherent perfect absorption (CPA) for bidirectional waves are obtained analytically for this system. The energy points at which total absorption occurs are shown to be the spectral singular points for the time reversed system. The possible energies at which CC occurs for left and right incidence are different. We further obtain periodic intervals with increasing periodicity of energy for CC and CPA to occur in this system. -- Highlights:more » •Energy ranges for CC and CPA are obtained explicitly for complex WS potential. •Analytical conditions for CC and CPA for PT symmetric WS potential are obtained. •Conditions for left and right CC are shown to be different. •Conditions for CC and CPA are shown to be that of SS for the time reversed system. •Our model shows the great flexibility of frequencies for CC and CPA.« less

  5. Women with breast cancer: self-reported distress in early survivorship.

    PubMed

    Lester, Joanne; Crosthwaite, Kara; Stout, Robin; Jones, Rachel N; Holloman, Christopher; Shapiro, Charles; Andersen, Barbara L

    2015-01-01

    To identify and compare levels of distress and sources of problems among patients with breast cancer in early survivorship. Descriptive, cross-sectional. A National Cancer Institute-designated comprehensive cancer center. 100 breast cancer survivors were selected to represent four time points in the cancer trajectory. Distress was self-reported using the Distress Thermometer and its 38-item problem list. Analysis of variance and chi-square analyses were performed as appropriate. Distress scores, problem reports, and time groups. Participants scored in range of the cutoff of more than 4 (range = 4.1-5.1) from treatment through three months post-treatment. At six months post-treatment, distress levels were significantly lower. Significant differences were found between groups on the total problem list score (p = 0.007) and emotional (p = 0.01) and physical subscale scores (p = 0.003). Comparison of groups at different points in the cancer trajectory found similar elevated levels from diagnosis through three months. Distress remained elevated in early survivorship but significantly decreased at six months post-treatment. Interventions to reduce or prevent distress may improve outcomes in early survivorship.

  6. Near constant-time optimal piecewise LDR to HDR inverse tone mapping

    NASA Astrophysics Data System (ADS)

    Chen, Qian; Su, Guan-Ming; Yin, Peng

    2015-02-01

    In a backward compatible HDR image/video compression, it is a general approach to reconstruct HDR from compressed LDR as a prediction to original HDR, which is referred to as inverse tone mapping. Experimental results show that 2- piecewise 2nd order polynomial has the best mapping accuracy than 1 piece high order or 2-piecewise linear, but it is also the most time-consuming method because to find the optimal pivot point to split LDR range to 2 pieces requires exhaustive search. In this paper, we propose a fast algorithm that completes optimal 2-piecewise 2nd order polynomial inverse tone mapping in near constant time without quality degradation. We observe that in least square solution, each entry in the intermediate matrix can be written as the sum of some basic terms, which can be pre-calculated into look-up tables. Since solving the matrix becomes looking up values in tables, computation time barely differs regardless of the number of points searched. Hence, we can carry out the most thorough pivot point search to find the optimal pivot that minimizes MSE in near constant time. Experiment shows that our proposed method achieves the same PSNR performance while saving 60 times computation time compared to the traditional exhaustive search in 2-piecewise 2nd order polynomial inverse tone mapping with continuous constraint.

  7. Correlated bursts and the role of memory range

    NASA Astrophysics Data System (ADS)

    Jo, Hang-Hyun; Perotti, Juan I.; Kaski, Kimmo; Kertész, János

    2015-08-01

    Inhomogeneous temporal processes in natural and social phenomena have been described by bursts that are rapidly occurring events within short time periods alternating with long periods of low activity. In addition to the analysis of heavy-tailed interevent time distributions, higher-order correlations between interevent times, called correlated bursts, have been studied only recently. As the underlying mechanism behind such correlated bursts is far from being fully understood, we devise a simple model for correlated bursts using a self-exciting point process with a variable range of memory. Whether a new event occurs is stochastically determined by a memory function that is the sum of decaying memories of past events. In order to incorporate the noise and/or limited memory capacity of systems, we apply two memory loss mechanisms: a fixed number or a variable number of memories. By analysis and numerical simulations, we find that too much memory effect may lead to a Poissonian process, implying that there exists an intermediate range of memory effect to generate correlated bursts comparable to empirical findings. Our conclusions provide a deeper understanding of how long-range memory affects correlated bursts.

  8. Optimal symmetric flight with an intermediate vehicle model

    NASA Technical Reports Server (NTRS)

    Menon, P. K. A.; Kelley, H. J.; Cliff, E. M.

    1983-01-01

    Optimal flight in the vertical plane with a vehicle model intermediate in complexity between the point-mass and energy models is studied. Flight-path angle takes on the role of a control variable. Range-open problems feature subarcs of vertical flight and singular subarcs. The class of altitude-speed-range-time optimization problems with fuel expenditure unspecified is investigated and some interesting phenomena uncovered. The maximum-lift-to-drag glide appears as part of the family, final-time-open, with appropriate initial and terminal transient exceeding level-flight drag, some members exhibiting oscillations. Oscillatory paths generally fail the Jacobi test for durations exceeding a period and furnish a minimum only for short-duration problems.

  9. The effect of physical activity on adult obesity: evidence from the Canadian NPHS panel.

    PubMed

    Sarma, Sisira; Zaric, Gregory S; Campbell, M Karen; Gilliland, Jason

    2014-07-01

    Although physical activity has been considered as an important modifiable risk factor for obesity, the empirical evidence on the relationship between physical activity and obesity is mixed. Observational studies in the public health literature fail to account for time-invariant unobserved heterogeneity and dynamics of weight, leading to biased estimation of the effect of physical activity on obesity. To overcome this limitation, we propose dynamic fixed-effects models to account for unobserved heterogeneity bias and the dynamics of obesity. We use nationally representative longitudinal data on the cohort of adults aged 18-50 years in 1994/95 from Canada's National Population Health Survey and followed them over 16 years. Obesity is measured by BMI (body mass index). After controlling for a wide range of socio-economic factors, the impact of four alternative measures of leisure-time physical activity (LTPA) and work-related physical activity (WRPA) are analyzed. The results show that each measure of LTPA exerts a negative effect on BMI and the effects are larger for females. Our key results show that participation in LTPA exceeding 1.5 kcal/kg per day (i.e., at least 30 min of walking) reduces BMI by about 0.11-0.14 points in males and 0.20 points in females relative to physically inactive counterparts. Compared to those who are inactive at workplace, being able to stand or walk at work is associated with a reduction in BMI in the range of 0.16-0.19 points in males and 0.24-0.28 points in females. Lifting loads at workplace is associated with a reduction in BMI by 0.2-0.3 points in males and 0.3-0.4 points in females relative to those who are reported sedentary. Policies aimed at promotion of LTPA combined with WRPA like walking or climbing stairs daily would help reduce adult obesity risks. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Ultrasonic ranging for the oculometer

    NASA Technical Reports Server (NTRS)

    Guy, W. J.

    1981-01-01

    Ultrasonic tracking techniques are investigated for an oculometer. Two methods are reported in detail. The first is based on measurements of time from the start of a transmit burst to a received echo. Knowing the sound velocity, distance can be calculated. In the second method, a continuous signal is transmitted. Target movement causes phase shifting of the echo. By accumulating these phase shifts, tracking from a set point can be achieved. Both systems have problems with contoured targets, but work well on flat plates and the back of a human head. Also briefly reported is an evaluation of an ultrasonic ranging system. Interface circuits make this system compatible with the echo time design. While the system is consistently accurate, it has a beam too narrow for oculometer use. Finally, comments are provided on a tracking system using the Doppler frequency shift to give range data.

  11. Arthroscopic rotator cuff repair in the weight-bearing shoulder.

    PubMed

    Kerr, Jacek; Borbas, Paul; Meyer, Dominik C; Gerber, Christian; Buitrago Téllez, Carlos; Wieser, Karl

    2015-12-01

    In wheelchair-dependent individuals, pain often develops because of rotator cuff tendon failure and/or osteoarthritis of the glenohumeral joint. The purposes of this study were to investigate (1) specific rotator cuff tear patterns, (2) structural healing, and (3) clinical outcomes after arthroscopic rotator cuff repair in a cohort of wheelchair-dependent patients. Forty-six shoulders with a mean follow-up of 46 months (range, 24-82 months; SD, 13 months) from a consecutive series of 61 shoulders in 56 patients (46 men and 10 women) undergoing arthroscopic rotator cuff repair were available for analysis. Clinical outcome analysis was performed using the Constant-Murley score, the Subjective Shoulder Value, and the American Shoulder and Elbow Surgeons score. The integrity of the repair was analyzed by ultrasound. Of the shoulders, 87% had supraspinatus involvement, 70% had subscapularis involvement, and 57% had an anterosuperior lesion involving both the supraspinatus and subscapularis. Despite an overall structural failure rate of 33%, the patients showed improvements in the Constant-Murley score from 50 points (range, 22-86 points; SD, 16 points) preoperatively to 80 points (range, 40-98 points; SD, 12 points) postoperatively and in the American Shoulder and Elbow Surgeons score from 56 points (range, 20-92 points; SD, 20 points) preoperatively to 92 points (range, 53-100 points; SD, 10 points) postoperatively, with a mean postoperative Subjective Shoulder Value of 84% (range, 25%-100%; SD, 17%). Failure of the rotator cuff in weight-bearing shoulders occurs primarily anterosuperiorly. Arthroscopic rotator cuff repair leads to a structural failure rate of 33% but satisfactory functional results with high patient satisfaction at midterm follow-up. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. The Effect of Hydraulic Gradient and Pattern of Conduit Systems on Tracing Tests: Bench-Scale Modeling.

    PubMed

    Mohammadi, Zargham; Gharaat, Mohammad Javad; Field, Malcolm

    2018-03-13

    Tracer breakthrough curves provide valuable information about the traced media, especially in inherently heterogeneous karst aquifers. In order to study the effect of variations in hydraulic gradient and conduit systems on breakthrough curves, a bench scale karst model was constructed. The bench scale karst model contains both matrix and a conduit. Eight tracing tests were conducted under a wide range of hydraulic gradients from 1 to greater than 5 for branchwork and network-conduit systems. Sampling points at varying distances from the injection point were utilized. Results demonstrate that mean tracer velocities, tracer mass recovery and linear rising slope of the breakthrough curves were directly controlled by hydraulic gradient. As hydraulic gradient increased, both one half the time for peak concentration and one fifth the time for peak concentration decreased. The results demonstrate the variations in one half the time for peak concentration and one fifth the time for peak concentration of the descending limb for different sampling points under differing hydraulic gradients are mainly controlled by the interactions of advection with dispersion. The results are discussed from three perspectives: different conduit systems, different hydraulic-gradient conditions, and different sampling points. The research confirmed the undeniable role of hydrogeological setting (i.e., hydraulic gradient and conduit system) on the shape of the breakthrough curve. The extracted parameters (mobile-fluid velocity, tracer-mass recovery, linear rising limb, one half the time for peak concentration, and one fifth the time for peak concentration) allow for differentiating hydrogeological settings and enhance interpretations the tracing tests in karst aquifers. © 2018, National Ground Water Association.

  13. Quality assurance of a gimbaled head swing verification using feature point tracking.

    PubMed

    Miura, Hideharu; Ozawa, Shuichi; Enosaki, Tsubasa; Kawakubo, Atsushi; Hosono, Fumika; Yamada, Kiyoshi; Nagata, Yasushi

    2017-01-01

    To perform dynamic tumor tracking (DTT) for clinical applications safely and accurately, gimbaled head swing verification is important. We propose a quantitative gimbaled head swing verification method for daily quality assurance (QA), which uses feature point tracking and a web camera. The web camera was placed on a couch at the same position for every gimbaled head swing verification, and could move based on a determined input function (sinusoidal patterns; amplitude: ± 20 mm; cycle: 3 s) in the pan and tilt directions at isocenter plane. Two continuous images were then analyzed for each feature point using the pyramidal Lucas-Kanade (LK) method, which is an optical flow estimation algorithm. We used a tapped hole as a feature point of the gimbaled head. The period and amplitude were analyzed to acquire a quantitative gimbaled head swing value for daily QA. The mean ± SD of the period were 3.00 ± 0.03 (range: 3.00-3.07) s and 3.00 ± 0.02 (range: 3.00-3.07) s in the pan and tilt directions, respectively. The mean ± SD of the relative displacement were 19.7 ± 0.08 (range: 19.6-19.8) mm and 18.9 ± 0.2 (range: 18.4-19.5) mm in the pan and tilt directions, respectively. The gimbaled head swing was reliable for DTT. We propose a quantitative gimbaled head swing verification method for daily QA using the feature point tracking method and a web camera. Our method can quantitatively assess the gimbaled head swing for daily QA from baseline values, measured at the time of acceptance and commissioning. © 2016 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  14. A surgical protocol of ankle arthrodesis with combined Ilizarov's distraction-compression osteogenesis and locked nailing for osteomyelitis around the ankle joint.

    PubMed

    Chen, Chuan-Mu; Su, Alvin W; Chiu, Fang-Yao; Chen, Tain-Hsiung

    2010-09-01

    Managing refractory osteomyelitis around the ankle joint has been challenging. Destruction of both the ankle and the subtalar joints was common in cases of open fracture. For those who already had multiple surgeries, it would be tough to salvage the limb. Our goal was to set up a staged surgical protocol aiming in treating the aforementioned clinical issue. Twelve male patients underwent our protocol since year 2000. All patients presented refractory osteomyelitis, ankle and subtalar joint destruction, and poor soft tissue condition. All cases had internal fixation for open fractures followed by multiple debridement surgery before. The mean age was 50.8 years (range, 37-71 years), and the median follow-up time was 61 months (range, 48-96 months). The surgical protocol consisted of radical debridement, distraction osteogenesis for segmental bone transport, and tibia lengthening to avoid leg length discrepancy followed by intramedullary nailing for tibio-talo-calcaneal arthrodesis. The external fixation period averaged 24.7 weeks (range, 12-36 weeks). The mean duration to solid union of the arthrodesis and the bridging callus was 18.3 weeks (range, 16-20 weeks). Mild surgical site infection occurred in four cases but all subsided after removal of the nail and oral antibiotics use. At latest follow-up, all patients were infection free and could walk with plantigrade feet. The mean American Orthopaedic Foot and Ankle Society hindfoot score rising from 21.5 points (range 20-24 points) preoperatively to 65.5 points (range, 60-72). This study has shown our staged surgical protocol may be effective in solving complicated osteomyelitis around the ankle, although salvaging the limb with successful ankle arthrodesis and minimized limb length inequality, yet improving the patients' ambulation level.

  15. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    PubMed

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important part of the pre-operative discussion.

  16. Ultrasonically Modified Amended-Cloud Point Extraction for Simultaneous Pre-Concentration of Neonicotinoid Insecticide Residues.

    PubMed

    Kachangoon, Rawikan; Vichapong, Jitlada; Burakham, Rodjana; Santaladchaiyakit, Yanawath; Srijaranai, Supalax

    2018-05-12

    An effective pre-concentration method, namely amended-cloud point extraction (CPE), has been developed for the extraction and pre-concentration of neonicotinoid insecticide residues. The studied analytes including clothianidin, imidacloprid, acetamiprid, thiamethoxam and thiacloprid were chosen as a model compound. The amended-CPE procedure included two cloud point processes. Triton™ X-114 was used to extract neonicotinoid residues into the surfactant-rich phase and then the analytes were transferred into an alkaline solution with the help of ultrasound energy. The extracts were then analyzed by high-performance liquid chromatography (HPLC) coupled with a monolithic column. Several factors influencing the extraction efficiency were studied such as kind and concentration of surfactant, type and content of salts, kind and concentration of back extraction agent, and incubation temperature and time. Enrichment factors (EFs) were found in the range of 20⁻333 folds. The limits of detection of the studied neonicotinoids were in the range of 0.0003⁻0.002 µg mL −1 which are below the maximum residue limits (MRLs) established by the European Union (EU). Good repeatability was obtained with relative standard deviations lower than 1.92% and 4.54% for retention time ( t R ) and peak area, respectively. The developed extraction method was successfully applied for the analysis of water samples. No detectable residues of neonicotinoids in the studied samples were found.

  17. 27 CFR 9.39 - Paicines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... The beginning point is the northwestern-most point of the proposed area at Township 14 South, Range 6... beginning point the boundary runs east along the north border of Sections 3, 2, and 1, Township 14 South, Range 6 East; (2) Thence south along the east border of Section 1, Township 14 South, Range 6 East...

  18. 27 CFR 9.39 - Paicines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... The beginning point is the northwestern-most point of the proposed area at Township 14 South, Range 6... beginning point the boundary runs east along the north border of Sections 3, 2, and 1, Township 14 South, Range 6 East; (2) Thence south along the east border of Section 1, Township 14 South, Range 6 East...

  19. Effect of virtual reality training on laparoscopic surgery: randomised controlled trial

    PubMed Central

    Soerensen, Jette L; Grantcharov, Teodor P; Dalsgaard, Torur; Schouenborg, Lars; Ottosen, Christian; Schroeder, Torben V; Ottesen, Bent S

    2009-01-01

    Objective To assess the effect of virtual reality training on an actual laparoscopic operation. Design Prospective randomised controlled and blinded trial. Setting Seven gynaecological departments in the Zeeland region of Denmark. Participants 24 first and second year registrars specialising in gynaecology and obstetrics. Interventions Proficiency based virtual reality simulator training in laparoscopic salpingectomy and standard clinical education (controls). Main outcome measure The main outcome measure was technical performance assessed by two independent observers blinded to trainee and training status using a previously validated general and task specific rating scale. The secondary outcome measure was operation time in minutes. Results The simulator trained group (n=11) reached a median total score of 33 points (interquartile range 32-36 points), equivalent to the experience gained after 20-50 laparoscopic procedures, whereas the control group (n=10) reached a median total score of 23 (22-27) points, equivalent to the experience gained from fewer than five procedures (P<0.001). The median total operation time in the simulator trained group was 12 minutes (interquartile range 10-14 minutes) and in the control group was 24 (20-29) minutes (P<0.001). The observers’ inter-rater agreement was 0.79. Conclusion Skills in laparoscopic surgery can be increased in a clinically relevant manner using proficiency based virtual reality simulator training. The performance level of novices was increased to that of intermediately experienced laparoscopists and operation time was halved. Simulator training should be considered before trainees carry out laparoscopic procedures. Trial registration ClinicalTrials.gov NCT00311792. PMID:19443914

  20. Wi-Fi real time location systems

    NASA Astrophysics Data System (ADS)

    Doll, Benjamin A.

    This thesis objective was to determine the viability of utilizing an untrained Wi-Fi. real time location system as a GPS alternative for indoor environments. Background. research showed that GPS is rarely able to penetrate buildings to provide reliable. location data. The benefit of having location information in a facility and how they might. be used for disaster or emergency relief personnel and their resources motivated this. research. A building was selected with a well-deployed Wi-Fi infrastructure and its. untrained location feature was used to determine the distance between the specified. test points and the system identified location. It was found that the average distance. from the test point throughout the facility was 14.3 feet 80% of the time. This fell within. the defined viable range and supported that an untrained Wi-Fi RTLS system could be a. viable solution for GPS's lack of availability indoors.

  1. CASOAR - An infrared active wave front sensor for atmospheric turbulence analysis

    NASA Astrophysics Data System (ADS)

    Cariou, Jean-Pierre; Dolfi, Agnes

    1992-12-01

    Knowledge of deformation of every point of a wave front over time allows statistical turbulence parameters to be analyzed, and the definition of real time adaptive optics to be designed. An optical instrumentation was built to meet this need. Integrated in a compact enclosure for experiments on outdoor sites, the CASOAR allows the deformations of a wave front to be measured rapidly (100 Hz) and with accuracy (1 deg). The CASOAR is an active system: it includes its own light source (CW CO2 laser), making it self-contained, self-aligned and insensitive to spurious light rays. After being reflected off a mirror located beyond the atmospheric layer to be analyzed (range of several kilometers), the beam is received and detected by coherent mixing. Electronic phase is converted in optical phase and recorded or displayed in real time on a monitor. Experimental results are shown, pointing out the capabilities of this device.

  2. Definition of a new thermal contrast and pulse correction for defect quantification in pulsed thermography

    NASA Astrophysics Data System (ADS)

    Benítez, Hernán D.; Ibarra-Castanedo, Clemente; Bendada, AbdelHakim; Maldague, Xavier; Loaiza, Humberto; Caicedo, Eduardo

    2008-01-01

    It is well known that the methods of thermographic non-destructive testing based on the thermal contrast are strongly affected by non-uniform heating at the surface. Hence, the results obtained from these methods considerably depend on the chosen reference point. The differential absolute contrast (DAC) method was developed to eliminate the need of determining a reference point that defined the thermal contrast with respect to an ideal sound area. Although, very useful at early times, the DAC accuracy decreases when the heat front approaches the sample rear face. We propose a new DAC version by explicitly introducing the sample thickness using the thermal quadrupoles theory and showing that the new DAC range of validity increases for long times while preserving the validity for short times. This new contrast is used for defect quantification in composite, Plexiglas™ and aluminum samples.

  3. SAR correlation technique - An algorithm for processing data with large range walk

    NASA Technical Reports Server (NTRS)

    Jin, M.; Wu, C.

    1983-01-01

    This paper presents an algorithm for synthetic aperture radar (SAR) azimuth correlation with extraneously large range migration effect which can not be accommodated by the existing frequency domain interpolation approach used in current SEASAT SAR processing. A mathematical model is first provided for the SAR point-target response in both the space (or time) and the frequency domain. A simple and efficient processing algorithm derived from the hybrid algorithm is then given. This processing algorithm enables azimuth correlation by two steps. The first step is a secondary range compression to handle the dispersion of the spectra of the azimuth response along range. The second step is the well-known frequency domain range migration correction approach for the azimuth compression. This secondary range compression can be processed simultaneously with range pulse compression. Simulation results provided here indicate that this processing algorithm yields a satisfactory compressed impulse response for SAR data with large range migration.

  4. Using phenomenological models for forecasting the 2015 Ebola challenge.

    PubMed

    Pell, Bruce; Kuang, Yang; Viboud, Cecile; Chowell, Gerardo

    2018-03-01

    The rising number of novel pathogens threatening the human population has motivated the application of mathematical modeling for forecasting the trajectory and size of epidemics. We summarize the real-time forecasting results of the logistic equation during the 2015 Ebola challenge focused on predicting synthetic data derived from a detailed individual-based model of Ebola transmission dynamics and control. We also carry out a post-challenge comparison of two simple phenomenological models. In particular, we systematically compare the logistic growth model and a recently introduced generalized Richards model (GRM) that captures a range of early epidemic growth profiles ranging from sub-exponential to exponential growth. Specifically, we assess the performance of each model for estimating the reproduction number, generate short-term forecasts of the epidemic trajectory, and predict the final epidemic size. During the challenge the logistic equation consistently underestimated the final epidemic size, peak timing and the number of cases at peak timing with an average mean absolute percentage error (MAPE) of 0.49, 0.36 and 0.40, respectively. Post-challenge, the GRM which has the flexibility to reproduce a range of epidemic growth profiles ranging from early sub-exponential to exponential growth dynamics outperformed the logistic growth model in ascertaining the final epidemic size as more incidence data was made available, while the logistic model underestimated the final epidemic even with an increasing amount of data of the evolving epidemic. Incidence forecasts provided by the generalized Richards model performed better across all scenarios and time points than the logistic growth model with mean RMS decreasing from 78.00 (logistic) to 60.80 (GRM). Both models provided reasonable predictions of the effective reproduction number, but the GRM slightly outperformed the logistic growth model with a MAPE of 0.08 compared to 0.10, averaged across all scenarios and time points. Our findings further support the consideration of transmission models that incorporate flexible early epidemic growth profiles in the forecasting toolkit. Such models are particularly useful for quickly evaluating a developing infectious disease outbreak using only case incidence time series of the early phase of an infectious disease outbreak. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Prospects for high accuracy time dissemination and synchronization using coded radar pulses from a low-earth orbiting spacecraft

    NASA Technical Reports Server (NTRS)

    Detoma, Edoardo V.; Dionisio, C.

    1995-01-01

    The radar (an acronym for radio detection and ranging) is an instrument developed just before the WW-II to precisely measure the position of an object (target) in space. This is done by emitting a narrow pulse of electromagnetic energy in the RF spectrum, receiving the return echo and measuring the time of flight in the two-way path from the emitter to the target. The propagation delay provides a measure of the range to the target, which is not in itself sufficient to uniquely locate the position of the same in space. However, if a directional antenna is used, the direction of the echo can be assessed by the antenna pointing angles. In this way the position of the target can be uniquely determined in space. How well this can be done is a function of the resolution of the measurements performed (range and direction, i.e.: angles); in turn, the resolution will dictate the time and frequency requirements of the reference oscillator.

  6. "Soft"or "hard" ionisation? Investigation of metastable gas temperature effect on direct analysis in real-time analysis of Voriconazole.

    PubMed

    Lapthorn, Cris; Pullen, Frank

    2009-01-01

    The performance of the direct analysis in real-time (DART) technique was evaluated across a range of metastable gas temperatures for a pharmaceutical compound, Voriconazole, in order to investigate the effect of metastable gas temperature on molecular ion intensity and fragmentation. The DART source has been used to analyse a range of analytes and from a range of matrices including drugs in solid tablet form and preparations, active ingredients in ointment, naturally occurring plant alkaloids, flavours and fragrances, from thin layer chromatography (TLC) plates, melting point tubes and biological matrices including hair, urine and blood. The advantages of this technique include rapid analysis time (as little as 5 s), a reduction in sample preparation requirements, elimination of mobile phase requirement and analysis of samples not typically amenable to atmospheric pressure ionisation (API) techniques. This technology has therefore been proposed as an everyday tool for identification of components in crude organic reaction mixtures.

  7. Net dextral slip, Neogene San Gregorio–Hosgri fault zone, coastal California: Geologic evidence and tectonic implications

    USGS Publications Warehouse

    Dickinson, William R.; Ducea, M.; Rosenberg, Lewis I.; Greene, H. Gary; Graham, Stephan A.; Clark, Joseph C.; Weber, Gerald E.; Kidder, Steven; Ernst, W. Gary; Brabb, Earl E.

    2005-01-01

    Reinterpretation of onshore and offshore geologic mapping, examination of a key offshore well core, and revision of cross-fault ties indicate Neogene dextral strike slip of 156 ± 4 km along the San Gregorio–Hosgri fault zone, a major strand of the San Andreas transform system in coastal California. Delineating the full course of the fault, defining net slip across it, and showing its relationship to other major tectonic features of central California helps clarify the evolution of the San Andreas system.San Gregorio–Hosgri slip rates over time are not well constrained, but were greater than at present during early phases of strike slip following fault initiation in late Miocene time. Strike slip took place southward along the California coast from the western fl ank of the San Francisco Peninsula to the Hosgri fault in the offshore Santa Maria basin without significant reduction by transfer of strike slip into the central California Coast Ranges. Onshore coastal segments of the San Gregorio–Hosgri fault include the Seal Cove and San Gregorio faults on the San Francisco Peninsula, and the Sur and San Simeon fault zones along the flank of the Santa Lucia Range.Key cross-fault ties include porphyritic granodiorite and overlying Eocene strata exposed at Point Reyes and at Point Lobos, the Nacimiento fault contact between Salinian basement rocks and the Franciscan Complex offshore within the outer Santa Cruz basin and near Esalen on the flank of the Santa Lucia Range, Upper Cretaceous (Campanian) turbidites of the Pigeon Point Formation on the San Francisco Peninsula and the Atascadero Formation in the southern Santa Lucia Range, assemblages of Franciscan rocks exposed at Point Sur and at Point San Luis, and a lithic assemblage of Mesozoic rocks and their Tertiary cover exposed near Point San Simeon and at Point Sal, as restored for intrabasinal deformation within the onshore Santa Maria basin.Slivering of the Salinian block by San Gregorio–Hosgri displacements elongated its northern end and offset its western margin delineated by the older Nacimiento fault, a sinistral strike-slip fault of latest Cretaceous to Paleocene age. North of its juncture with the San Andreas fault, dextral slip along the San Gregorio–Hosgri fault augments net San Andreas displacement. Alternate restorations of the Gualala block imply that nearly half the net San Gregorio–Hosgri slip was accommodated along the offshore Gualala fault strand lying west of the Gualala block, which is bounded on the east by the current master trace of the San Andreas fault. With San Andreas and San Gregorio–Hosgri slip restored, there remains an unresolved proto–San Andreas mismatch of ∼100 km between the offset northern end of the Salinian block and the southern end of the Sierran-Tehachapi block.On the south, San Gregorio–Hosgri strike slip is transposed into crustal shortening associated with vertical-axis tectonic rotation of fault-bounded crustal panels that form the western Transverse Ranges, and with kinematically linked deformation within the adjacent Santa Maria basin. The San Gregorio–Hosgri fault serves as the principal link between transrotation in the western Transverse Ranges and strike slip within the San Andreas transform system of central California.

  8. In situ two-dimensional imaging quick-scanning XAFS with pixel array detector.

    PubMed

    Tanida, Hajime; Yamashige, Hisao; Orikasa, Yuki; Oishi, Masatsugu; Takanashi, Yu; Fujimoto, Takahiro; Sato, Kenji; Takamatsu, Daiko; Murayama, Haruno; Arai, Hajime; Matsubara, Eiichiro; Uchimoto, Yoshiharu; Ogumi, Zempachi

    2011-11-01

    Quick-scanning X-ray absorption fine structure (XAFS) measurements were performed in transmission mode using a PILATUS 100K pixel array detector (PAD). The method can display a two-dimensional image for a large area of the order of a centimetre with a spatial resolution of 0.2 mm at each energy point in the XAFS spectrum. The time resolution of the quick-scanning method ranged from 10 s to 1 min per spectrum depending on the energy range. The PAD has a wide dynamic range and low noise, so the obtained spectra have a good signal-to-noise ratio.

  9. Time-Accurate, Unstructured-Mesh Navier-Stokes Computations with the Space-Time CESE Method

    NASA Technical Reports Server (NTRS)

    Chang, Chau-Lyan

    2006-01-01

    Application of the newly emerged space-time conservation element solution element (CESE) method to compressible Navier-Stokes equations is studied. In contrast to Euler equations solvers, several issues such as boundary conditions, numerical dissipation, and grid stiffness warrant systematic investigations and validations. Non-reflecting boundary conditions applied at the truncated boundary are also investigated from the stand point of acoustic wave propagation. Validations of the numerical solutions are performed by comparing with exact solutions for steady-state as well as time-accurate viscous flow problems. The test cases cover a broad speed regime for problems ranging from acoustic wave propagation to 3D hypersonic configurations. Model problems pertinent to hypersonic configurations demonstrate the effectiveness of the CESE method in treating flows with shocks, unsteady waves, and separations. Good agreement with exact solutions suggests that the space-time CESE method provides a viable alternative for time-accurate Navier-Stokes calculations of a broad range of problems.

  10. Temporal fractals in seabird foraging behaviour: diving through the scales of time

    PubMed Central

    MacIntosh, Andrew J. J.; Pelletier, Laure; Chiaradia, Andre; Kato, Akiko; Ropert-Coudert, Yan

    2013-01-01

    Animal behaviour exhibits fractal structure in space and time. Fractal properties in animal space-use have been explored extensively under the Lévy flight foraging hypothesis, but studies of behaviour change itself through time are rarer, have typically used shorter sequences generated in the laboratory, and generally lack critical assessment of their results. We thus performed an in-depth analysis of fractal time in binary dive sequences collected via bio-logging from free-ranging little penguins (Eudyptula minor) across full-day foraging trips (216 data points; 4 orders of temporal magnitude). Results from 4 fractal methods show that dive sequences are long-range dependent and persistent across ca. 2 orders of magnitude. This fractal structure correlated with trip length and time spent underwater, but individual traits had little effect. Fractal time is a fundamental characteristic of penguin foraging behaviour, and its investigation is thus a promising avenue for research on interactions between animals and their environments. PMID:23703258

  11. Spatial search on a two-dimensional lattice with long-range interactions

    NASA Astrophysics Data System (ADS)

    Osada, Tomo; Sanaka, Kaoru; Munro, William J.; Nemoto, Kae

    2018-06-01

    Quantum-walk-based algorithms that search a marked location among N locations on a d -dimensional lattice succeeds in time O (√{N }) for d >2 , while this is not found to be possible when d =2 . In this paper, we consider a spatial search algorithm using continuous-time quantum walk on a two-dimensional square lattice with the existence of additional long-range edges. We examined such a search on a probabilistic graph model where an edge connecting non-nearest-neighbor lattice points i and j apart by a distance |i -j | is added by probability pi j=|i-j | -α(α ≥0 ) . Through numerical analysis, we found that the search succeeds in time O (√{N }) when α ≤αc=2.4 ±0.1 . For α >2 , the expectation value of the additional long-range edges on each node scales as a constant when N →∞ , which means that search time of O (√{N }) is achieved on a graph with average degree scaling as a constant.

  12. Automatic Detection and Classification of Pole-Like Objects for Urban Cartography Using Mobile Laser Scanning Data

    PubMed Central

    Ordóñez, Celestino; Cabo, Carlos; Sanz-Ablanedo, Enoc

    2017-01-01

    Mobile laser scanning (MLS) is a modern and powerful technology capable of obtaining massive point clouds of objects in a short period of time. Although this technology is nowadays being widely applied in urban cartography and 3D city modelling, it has some drawbacks that need to be avoided in order to strengthen it. One of the most important shortcomings of MLS data is concerned with the fact that it provides an unstructured dataset whose processing is very time-consuming. Consequently, there is a growing interest in developing algorithms for the automatic extraction of useful information from MLS point clouds. This work is focused on establishing a methodology and developing an algorithm to detect pole-like objects and classify them into several categories using MLS datasets. The developed procedure starts with the discretization of the point cloud by means of a voxelization, in order to simplify and reduce the processing time in the segmentation process. In turn, a heuristic segmentation algorithm was developed to detect pole-like objects in the MLS point cloud. Finally, two supervised classification algorithms, linear discriminant analysis and support vector machines, were used to distinguish between the different types of poles in the point cloud. The predictors are the principal component eigenvalues obtained from the Cartesian coordinates of the laser points, the range of the Z coordinate, and some shape-related indexes. The performance of the method was tested in an urban area with 123 poles of different categories. Very encouraging results were obtained, since the accuracy rate was over 90%. PMID:28640189

  13. Human immunodeficiency virus prevalence, incidence, and residual transmission risk in first-time and repeat blood donations in Zimbabwe: implications on blood safety.

    PubMed

    Mapako, Tonderai; Mvere, David A; Chitiyo, McLeod E; Rusakaniko, Simbarashe; Postma, Maarten J; van Hulst, Marinus

    2013-10-01

    National Blood Service Zimbabwe human immunodeficiency virus (HIV) risk management strategy includes screening and discarding of first-time donations, which are collected in blood packs without an anticoagulant (dry pack). To evaluate the impact of discarding first-time donations on blood safety the HIV prevalence, incidence, and residual risk in first-time and repeat donations (wet packs) were compared. Donor data from 2002 to 2010 were retrieved from a centralized national electronic donor database and retrospectively analyzed. Chi-square test was used to compare HIV prevalence with relative risk (RR), and the RR point estimates and 95% confidence interval (CI) are reported. Trend analysis was done using Cochran-Armitage trend test. HIV residual risk estimates were determined using published residual risk estimation models. Over the 9 years the overall HIV prevalence estimates are 1.29% (n = 116,058) and 0.42% (n = 434,695) for first-time and repeat donations, respectively. The overall RR was 3.1 (95% CI, 2.9-3.3; p < 0.0001). The overall mean residual transmission risk of HIV window phase donations in first-time was 1:7384 (range, 1:11,308-1:5356) and in repeat donors it was 1:5496 (range, 1:9943-1:3347). The significantly high HIV prevalence estimates recorded in first-time over repeat donations is indicative of the effectiveness of the HIV risk management strategy. However, comparable residual transmission risk estimates in first-time and repeat donors point to the need to further review the risk management strategies. Given the potential wastage of valuable resources, future studies should focus on the cost-effectiveness and utility of screening and discarding first-time donations. © 2013 American Association of Blood Banks.

  14. Point-of-care oral-based diagnostics

    PubMed Central

    Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH

    2014-01-01

    Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419

  15. Effect of low-level pulsed laser 890-nm on lumbar spondylolisthesis: a case report

    NASA Astrophysics Data System (ADS)

    Mortazavi, Seyed M. J.; Afsharpad, Mitra; Djavid, Gholam-reza E.

    2002-10-01

    Objective: Evaluating the effectiveness of low-level laser therapy (LLLT) in alleviating the symptoms of lumbar spondylolisthesis. Materials and Methods: Laser was irradiated for 2 mm at six symmetric points along the lumbosacral spine and 5 points along the referred point ofpain, six times a week for 2 weeks (890 nm; 8 J/cm2; pulsed at 1500 Hz). Perception of benefit, level of function was assessed by the Oswestry disability index, lumbar mobility range of motion and low back pain intensity. Results and Discussion: Results showed a complete reduction in pain and improvement in function in the patient. This case report suggests that low-level laser therapy (LLLT) could play a role in conservative management of low-grade lumbar spondylolisthesis.

  16. The calibration of photographic and spectroscopic films. Part 1: Film batch variations of reciprocity failure in IIaO film. Part 2: Thermal and aging effects in relationship to reciprocity failure. P art 3: Shifting of reciprocity failure points as a function of thermal and aging effects

    NASA Technical Reports Server (NTRS)

    Peters, Kevin A.; Atkinson, Pamela F.; Hammond, Ernest C., Jr

    1987-01-01

    Reciprocity failure was examined for IIaO spectroscopic film. Three separate experiments were performed in order to study film batch variations, thermal and aging effects in relationship to reciprocity failure, and shifting of reciprocity failure points as a function of thermal and aging effects. The failure was examined over ranges of time between 5 and 60 seconds. The variation to illuminance was obtained by using thirty neutral density filters. A standard sensitometer device imprinted the wedge pattern on the film as exposure time was subjected to variation. Results indicate that film batch differences, temperature, and aging play an important role in reciprocity failure of IIaO spectroscopic film. A shifting of the failure points was also observed in various batches of film.

  17. A simple, remote, video based breathing monitor.

    PubMed

    Regev, Nir; Wulich, Dov

    2017-07-01

    Breathing monitors have become the all-important cornerstone of a wide variety of commercial and personal safety applications, ranging from elderly care to baby monitoring. Many such monitors exist in the market, some, with vital signs monitoring capabilities, but none remote. This paper presents a simple, yet efficient, real time method of extracting the subject's breathing sinus rhythm. Points of interest are detected on the subject's body, and the corresponding optical flow is estimated and tracked using the well known Lucas-Kanade algorithm on a frame by frame basis. A generalized likelihood ratio test is then utilized on each of the many interest points to detect which is moving in harmonic fashion. Finally, a spectral estimation algorithm based on Pisarenko harmonic decomposition tracks the harmonic frequency in real time, and a fusion maximum likelihood algorithm optimally estimates the breathing rate using all points considered. The results show a maximal error of 1 BPM between the true breathing rate and the algorithm's calculated rate, based on experiments on two babies and three adults.

  18. Speed Approach for UAV Collision Avoidance

    NASA Astrophysics Data System (ADS)

    Berdonosov, V. D.; Zivotova, A. A.; Htet Naing, Zaw; Zhuravlev, D. O.

    2018-05-01

    The article represents a new approach of defining potential collision of two or more UAVs in a common aviation area. UAVs trajectories are approximated by two or three trajectories’ points obtained from the ADS-B system. In the process of defining meeting points of trajectories, two cutoff values of the critical speed range, at which a UAVs collision is possible, are calculated. As calculation expressions for meeting points and cutoff values of the critical speed are represented in the analytical form, even if an on-board computer system has limited computational capacity, the time for calculation will be far less than the time of receiving data from ADS-B. For this reason, calculations can be updated at each cycle of new data receiving, and the trajectory approximation can be bounded by straight lines. Such approach allows developing the compact algorithm of collision avoidance, even for a significant amount of UAVs (more than several dozens). To proof the research adequacy, modeling was performed using a software system developed specifically for this purpose.

  19. Instructional versus schedule control of humans' choices in situations of diminishing returns

    PubMed Central

    Hackenberg, Timothy D.; Joker, Veronica R.

    1994-01-01

    Four adult humans chose repeatedly between a fixed-time schedule (of points later exchangeable for money) and a progressive-time schedule that began at 0 s and increased by a fixed number of seconds with each point delivered by that schedule. Each point delivered by the fixed-time schedule reset the requirements of the progressive-time schedule to its minimum value. Subjects were provided with instructions that specified a particular sequence of choices. Under the initial conditions, the instructions accurately specified the optimal choice sequence. Thus, control by instructions and optimal control by the programmed contingencies both supported the same performance. To distinguish the effects of instructions from schedule sensitivity, the correspondence between the instructed and optimal choice patterns was gradually altered across conditions by varying the step size of the progressive-time schedule while maintaining the same instructions. Step size was manipulated, typically in 1-s units, first in an ascending and then in a descending sequence of conditions. Instructions quickly established control in all 4 subjects but, by narrowing the range of choice patterns, they reduced subsequent sensitivity to schedule changes. Instructional control was maintained across the ascending sequence of progressive-time values for each subject, but eventually diminished, giving way to more schedule-appropriate patterns. The transition from instruction-appropriate to schedule-appropriate behavior was characterized by an increase in the variability of choice patterns and local increases in point density. On the descending sequence of progressive-time values, behavior appeared to be schedule sensitive, sometimes even optimally sensitive, but it did not always change systematically with the contingencies, suggesting the involvement of other factors. PMID:16812747

  20. Spatial Representativeness of Surface-Measured Variations of Downward Solar Radiation

    NASA Astrophysics Data System (ADS)

    Schwarz, M.; Folini, D.; Hakuba, M. Z.; Wild, M.

    2017-12-01

    When using time series of ground-based surface solar radiation (SSR) measurements in combination with gridded data, the spatial and temporal representativeness of the point observations must be considered. We use SSR data from surface observations and high-resolution (0.05°) satellite-derived data to infer the spatiotemporal representativeness of observations for monthly and longer time scales in Europe. The correlation analysis shows that the squared correlation coefficients (R2) between SSR times series decrease linearly with increasing distance between the surface observations. For deseasonalized monthly mean time series, R2 ranges from 0.85 for distances up to 25 km between the stations to 0.25 at distances of 500 km. A decorrelation length (i.e., the e-folding distance of R2) on the order of 400 km (with spread of 100-600 km) was found. R2 from correlations between point observations and colocated grid box area means determined from satellite data were found to be 0.80 for a 1° grid. To quantify the error which arises when using a point observation as a surrogate for the area mean SSR of larger surroundings, we calculated a spatial sampling error (SSE) for a 1° grid of 8 (3) W/m2 for monthly (annual) time series. The SSE based on a 1° grid, therefore, is of the same magnitude as the measurement uncertainty. The analysis generally reveals that monthly mean (or longer temporally aggregated) point observations of SSR capture the larger-scale variability well. This finding shows that comparing time series of SSR measurements with gridded data is feasible for those time scales.

  1. FIRST-ORDER COSMOLOGICAL PERTURBATIONS ENGENDERED BY POINT-LIKE MASSES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eingorn, Maxim, E-mail: maxim.eingorn@gmail.com

    2016-07-10

    In the framework of the concordance cosmological model, the first-order scalar and vector perturbations of the homogeneous background are derived in the weak gravitational field limit without any supplementary approximations. The sources of these perturbations (inhomogeneities) are presented in the discrete form of a system of separate point-like gravitating masses. The expressions found for the metric corrections are valid at all (sub-horizon and super-horizon) scales and converge at all points except at the locations of the sources. The average values of these metric corrections are zero (thus, first-order backreaction effects are absent). Both the Minkowski background limit and the Newtonianmore » cosmological approximation are reached under certain well-defined conditions. An important feature of the velocity-independent part of the scalar perturbation is revealed: up to an additive constant, this part represents a sum of Yukawa potentials produced by inhomogeneities with the same finite time-dependent Yukawa interaction range. The suggested connection between this range and the homogeneity scale is briefly discussed along with other possible physical implications.« less

  2. Agreement of Tracing and Direct Viewing Techniques for Cervical Vertebral Maturation Assessment.

    PubMed

    Wiwatworakul, Opas; Manosudprasit, Montian; Pisek, Poonsak; Chatrchaiwiwatana, Supaporn; Wangsrimongkol, Tasanee

    2015-08-01

    This study aimed to evaluate agreement among three methods for cervical vertebral maturation (CVM) assessment, comprising direct viewing, tracing only, and tracing with digitized points. Two examiners received training and tests of reliability with each CVM method before evaluation of agreement among methods. The subjects were 96 female-cleft lateral cephalometric radiographs (films of eight subjects for each age ranged from seven to 18 years). The examiners interpreted CVM stages of the subjects with four-week interval between uses of each method. The range of weighted kappa values for paired comparisons among the three methods were: 0.96-0.98 for direct viewing and tracing only comparison; 0.93-0.94 for direct viewing and tracing with digitized points comparison; and 0.96-0.97 for tracing only and tracing with digitized points comparison. The intraclass correlation coefficient (ICC) value among the three methods was 0.95. These results indicated very good agreement among methods. Use of direct viewing is suitable for CVM assessment without spending more time for tracing. However, the three methods might be used interchangeably.

  3. A Novel Methodology for the Synthesis of Acyloxy Castor Polyol Esters: Low Pour Point Lubricant Base Stocks.

    PubMed

    Kamalakar, Kotte; Mahesh, Goli; Prasad, Rachapudi B N; Karuna, Mallampalli S L

    2015-01-01

    Castor oil, a non-edible oil containing hydroxyl fatty acid, ricinoleic acid (89.3 %) was chemically modified employing a two step procedure. The first step involved acylation (C(2)-C(6) alkanoic anhydrides) of -OH functionality employing a green catalyst, Kieselguhr-G and solvent free medium. The catalyst after reaction was filtered and reused several times without loss in activity. The second step is esterification of acylated castor fatty acids with branched mono alcohol, 2-ethylhexanol and polyols namely neopentyl glycol (NPG), trimethylolpropane (TMP) and pentaerythritol (PE) to obtain 16 novel base stocks. The base stocks when evaluated for different lubricant properties have shown very low pour points (-30 to -45°C) and broad viscosity ranges 20.27 cSt to 370.73 cSt, higher viscosity indices (144-171), good thermal and oxidative stabilities, and high weld load capacities suitable for multi-range industrial applications such as hydraulic fluids, metal working fluids, gear oil, forging and aviation applications. The study revealed that acylated branched mono- and polyol esters rich in monounsaturation is desirable for developing low pour point base stocks.

  4. Tibio-talo-calcaneal arthrodesis by a retrograde intramedullary nail.

    PubMed

    Haaker, Rolf; Kohja, E Y; Wojciechowski, Mariusz; Gruber, Gerd

    2010-01-01

    The paper presents the results of tibio-talo-calcaneal fusions using Retrograde Nailing System and Bone Grafting. From May 2006 to January 2008, we performed 13 fusions in 11 consecutive patients with advanced ankle and hindfoot disease. Patients underwent 13 tibiotalocalcaneal fusions (2 patients had initial tibiotalocalcaneal fusion using screws and subsequently developed a non-union) and all 11 patients were available for follow up. The procedure was performed unilaterally in all cases; there were 4 males and 7 females. The average age at the time of surgery was 65.25 years (range 51-81 years). The average duration of follow-up was 8 months (range between 6-15 months). Solid fusion was achieved in all 11 cases. The average AOFAS score (maximum 78 points) improved from a pre-operative mean of 16 points [range 3 to 29] to a mean of 54 points [range 42 to 70], excluding the scores for stability and range of motion. Patient satisfaction scale (maximum 10 points) improved from 3 to 7 in both pain and function. 1- Arthrodesis should be considered only after all conservative treatments fails; it is one of the most challenging surgical procedures that must be undertaken with care in order to provide the best possible outcome. 2- Thorough evaluation and examination will help the surgeon to find the correct indication and identify patients who are not suitable for the procedure. It is crucial to assess the vascular and neurological status and to obtain weight-bearing radiographs (possibly CT) of the ankle to evaluate the deformity. 3- The optimal position of the ankle is in neutral flexion, 0-5 degrees valgus, and 10 degrees external rotation, similar to the contralateral foot and posterior translation of the talus under the tibia (5mm). 4- Tibio-talo-calcaneal fusion with retrograde nailing and bone grafting is a successful salvage procedure in severe ankle and hind foot arthrosis with deformity.

  5. Stokes-Einstein relation of the liquid metal rubidium and its relationship to changes in the microscopic dynamics with increasing temperature

    NASA Astrophysics Data System (ADS)

    Demmel, F.; Tani, A.

    2018-06-01

    For liquid rubidium the Stokes-Einstein (SE) relation is well fulfilled near the melting point with an effective hydrodynamic diameter, which agrees well with a value from structural investigations. A wealth of thermodynamic and microscopic data exists for a wide range of temperatures for liquid rubidium and hence it represents a good test bed to challenge the SE relation with rising temperature from an experimental point of view. We performed classical molecular dynamics simulations to complement the existing experimental data using a pseudopotential, which describes perfectly the structure and dynamics of liquid rubidium. The derived SE relation from combining experimental shear viscosity data with simulated diffusion coefficients reveals a weak violation at about 1.3 Tmelting≈400 K. The microscopic relaxation dynamics on nearest neighbor distances from neutron spectroscopy demonstrate distinct changes in the amplitude with rising temperature. The derived average relaxation time for density fluctuations on this length scale shows a non-Arrhenius behavior, with a slope change around 1.5 Tmelting≈450 K. Combining the simulated macroscopic self-diffusion coefficient with that microscopic average relaxation time, a distinct violation of the SE relation in the same temperature range can be demonstrated. One can conclude that the changes in the collective dynamics, a mirror of the correlated movements of the particles, are at the origin for the violation of the SE relation. The changes in the dynamics can be understood as a transition from a more viscous liquid metal to a more fluid-like liquid above the crossover temperature range of 1.3-1.5 Tmelting. The decay of the amplitude of density fluctuations in liquid aluminium, lead, and rubidium demonstrates a remarkable agreement and points to a universal thermal crossover in the dynamics of liquid metals.

  6. Generation of Hummocky Flow Morphology Revealed through Ground-based LiDAR Measurements of Actively Inflating Pahoehoe Lavas

    NASA Astrophysics Data System (ADS)

    Anderson, S. W.; Finnegan, D. C.; Byrnes, J. M.; Nicoll, K.

    2007-12-01

    Although the extrusion of pahoehoe lava flows is one of the most dominant planetary surface-forming processes in the solar system, emplacement models remain controversial, and affect our ability to understand the implications of continental effusive eruptions. To study the detailed growth patterns of an actively inflating hummocky pahoehoe field in Hawaii, we used a Riegl LMSZ420i ground-based light detection and ranging (LiDAR) system that captures topographic data at unprecedented resolutions and speed, and co-registers the x, y and z coordinates with the RGB values of true color high-resolution (12 megapixel) photographs from an externally-mounted camera. Over a 3-day period (February 21-23, 2007) we acquired 4 surveys of surface topography over a ~200 x 200 m area within the Pu'u O'o flow field that contained actively inflating pahoehoe flows emplaced over older, hummocky pahoehoe lavas. Total scan times ranged from 6 to 19 minutes, with topographic points collected at a 0.05-0.08 degree spacing. Each scan obtained between 1.6 and 5.1 million x, y, and z data points. We acquired topographic data at a rate of 12,000 points/second, permitting repeatable digital elevation model (DEM) generation with 5mm accuracy. We differenced successive DEMs generated from our topographic data to determine the magnitude and patterns of growth. We documented uneven rates of inflation over the area, ranging from less than 0.5 m to 3.9 m, with several tumuli forming over the 3-day time period. These results are the first detailed measurements that help us constrain the movement of lava between upper and lower flow crusts.

  7. A new approach of the Star Excursion Balance Test to assess dynamic postural control in people complaining from chronic ankle instability.

    PubMed

    Pionnier, Raphaël; Découfour, Nicolas; Barbier, Franck; Popineau, Christophe; Simoneau-Buessinger, Emilie

    2016-03-01

    The purpose of this study was to quantitatively and qualitatively assess dynamic balance with accuracy in individuals with chronic ankle instability (CAI). To this aim, a motion capture system was used while participants performed the Star Excursion Balance Test (SEBT). Reached distances for the 8 points of the star were automatically computed, thereby excluding any dependence to the experimenter. In addition, new relevant variables were also computed, such as absolute time needed to reach each distance, lower limb ranges of motion during unipodal stance, as well as absolute error of pointing. Velocity of the center of pressure and range of variation of ground reaction forces have also been assessed during the unipodal phase of the SEBT thanks to force plates. CAI group exhibited smaller reached distances and greater absolute error of pointing than the control group (p<0.05). Moreover, the ranges of motion of lower limbs joints, the velocity of the center of pressure and the range of variation of the ground reaction forces were all significantly smaller in the CAI group (p<0.05). These reduced quantitative and qualitative performances highlighted a lower dynamic postural control. The limited body movements and accelerations during the unipodal stance in the CAI group could highlight a protective strategy. The present findings could help clinicians to better understand the motor strategies used by CAI patients during dynamic balance and may guide the rehabilitation process. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Detecting Signatures of GRACE Sensor Errors in Range-Rate Residuals

    NASA Astrophysics Data System (ADS)

    Goswami, S.; Flury, J.

    2016-12-01

    In order to reach the accuracy of the GRACE baseline, predicted earlier from the design simulations, efforts are ongoing since a decade. GRACE error budget is highly dominated by noise from sensors, dealiasing models and modeling errors. GRACE range-rate residuals contain these errors. Thus, their analysis provides an insight to understand the individual contribution to the error budget. Hence, we analyze the range-rate residuals with focus on contribution of sensor errors due to mis-pointing and bad ranging performance in GRACE solutions. For the analysis of pointing errors, we consider two different reprocessed attitude datasets with differences in pointing performance. Then range-rate residuals are computed from these two datasetsrespectively and analysed. We further compare the system noise of four K-and Ka- band frequencies of the two spacecrafts, with range-rate residuals. Strong signatures of mis-pointing errors can be seen in the range-rate residuals. Also, correlation between range frequency noise and range-rate residuals are seen.

  9. Access to care for children and young people diagnosed with localized scleroderma or juvenile SSc in the UK.

    PubMed

    Hawley, Daniel P; Baildam, Eileen M; Amin, Tania S; Cruikshank, Mary K; Davidson, Joyce E; Dixon, Jennifer; Martin, Neil S; Ohlsson, Victoria; Pilkington, Clarissa; Rangaraj, Satyapal; Riley, Philip; Sundaramoorthy, Chitra; Walsh, Jo; Foster, Helen E

    2012-07-01

    To describe pathways of care and referral to paediatric rheumatology from onset of first symptom (noticed by the patient or their family) to diagnosis for children and young people diagnosed with localized scleroderma (LS) or juvenile SSc (jSSc). Retrospective case note audit of patients under paediatric rheumatology care who presented during January 2005-January 2010. Data included disease subtype, sex, age at key points in the referral pathway and health care professional (HCP) contact. All patient and HCP data were pseudo-anonymized in accordance with good clinical practice. Data were from eight UK centres that saw 89 cases: 62 females, 26 males; 73 LS, 16 jSSc. Median time from first symptom to first HCP review was 4 (range 0-72) months (LS) and 1 (range 0-50) month (jSSc). Median time from first symptom to paediatric rheumatology review was 15 (range 1-103) months (LS) and 7 (range 0-50) months (jSSc). Median time from first HCP review to first paediatric rheumatology review was 11 (range 0-103) months (LS) and 2 (range 0-10) months. First HCP seen (74%) was usually a general practitioner. The referring HCP to paediatric rheumatology was usually a dermatologist (56%) for LS. Median time from first symptom to diagnosis was 13 (range 1-102) months (LS) and 8 (range 1-50) months (jSSc). A prolonged interval occurs from first symptom to definitive diagnosis, which may adversely affect outcome. There is a need to raise awareness of this rare diagnosis and facilitate earlier recognition.

  10. Implementation of real-time nonuniformity correction with multiple NUC tables using FPGA in an uncooled imaging system

    NASA Astrophysics Data System (ADS)

    Oh, Gyong Jin; Kim, Lyang-June; Sheen, Sue-Ho; Koo, Gyou-Phyo; Jin, Sang-Hun; Yeo, Bo-Yeon; Lee, Jong-Ho

    2009-05-01

    This paper presents a real time implementation of Non Uniformity Correction (NUC). Two point correction and one point correction with shutter were carried out in an uncooled imaging system which will be applied to a missile application. To design a small, light weight and high speed imaging system for a missile system, SoPC (System On a Programmable Chip) which comprises of FPGA and soft core (Micro-blaze) was used. Real time NUC and generation of control signals are implemented using FPGA. Also, three different NUC tables were made to make the operating time shorter and to reduce the power consumption in a large range of environment temperature. The imaging system consists of optics and four electronics boards which are detector interface board, Analog to Digital converter board, Detector signal generation board and Power supply board. To evaluate the imaging system, NETD was measured. The NETD was less than 160mK in three different environment temperatures.

  11. Identifying Variability in Mental Models Within and Between Disciplines Caring for the Cardiac Surgical Patient.

    PubMed

    Brown, Evans K H; Harder, Kathleen A; Apostolidou, Ioanna; Wahr, Joyce A; Shook, Douglas C; Farivar, R Saeid; Perry, Tjorvi E; Konia, Mojca R

    2017-07-01

    The cardiac operating room is a complex environment requiring efficient and effective communication between multiple disciplines. The objectives of this study were to identify and rank critical time points during the perioperative care of cardiac surgical patients, and to assess variability in responses, as a correlate of a shared mental model, regarding the importance of these time points between and within disciplines. Using Delphi technique methodology, panelists from 3 institutions were tasked with developing a list of critical time points, which were subsequently assigned to pause point (PP) categories. Panelists then rated these PPs on a 100-point visual analog scale. Descriptive statistics were expressed as percentages, medians, and interquartile ranges (IQRs). We defined low response variability between panelists as an IQR ≤ 20, moderate response variability as an IQR > 20 and ≤ 40, and high response variability as an IQR > 40. Panelists identified a total of 12 PPs. The PPs identified by the highest number of panelists were (1) before surgical incision, (2) before aortic cannulation, (3) before cardiopulmonary bypass (CPB) initiation, (4) before CPB separation, and (5) at time of transfer of care from operating room (OR) to intensive care unit (ICU) staff. There was low variability among panelists' ratings of the PP "before surgical incision," moderate response variability for the PPs "before separation from CPB," "before transfer from OR table to bed," and "at time of transfer of care from OR to ICU staff," and high response variability for the remaining 8 PPs. In addition, the perceived importance of each of these PPs varies between disciplines and between institutions. Cardiac surgical providers recognize distinct critical time points during cardiac surgery. However, there is a high degree of variability within and between disciplines as to the importance of these times, suggesting an absence of a shared mental model among disciplines caring for cardiac surgical patients during the perioperative period. A lack of a shared mental model could be one of the factors contributing to preventable errors in cardiac operating rooms.

  12. Passenger comfort response times as a function of aircraft motion

    NASA Technical Reports Server (NTRS)

    Rinalducci, E. J.

    1975-01-01

    The relationship between a passenger's response time of changes in level of comfort experienced as a function of aircraft motion was examined. The aircraft used in this investigation was capable of providing a wide range of vertical and transverse accelerations by means of direct lift flap control surfaces and side force generator surfaces in addition to normal control surfaces. Response times to changes in comfort were recorded along with the passenger's rating of comfort on a five point scale. In addition, a number of aircraft motion variables including vertical and transverse accelerations were also recorded. Results indicate some relationship between human comfort response times to reaction time data.

  13. ENVIRONMENTAL IMPACT ASSESSMENT TAXONOMY PROVIDING COMPREHENSIVE COVERAGE OF MIDPOINTS, ENDPOINTS, DAMAGES, AND AREAS OF PROTECTION

    EPA Science Inventory

    Prior to conducting a comprehensive impact assessment, such as a Life Cycle Impact Assessment (LCIA), there is a need to discuss the range of impacts which could and should be included. Up to this point in time, there has not been available a comprehensive list of impacts for po...

  14. Simultaneous saccharification and ethanol fermentation of oxalic acid pretreated corncob assessed with response surface methodology

    Treesearch

    Jae-Won Lee; Rita C.L.B. Rodrigues; Thomas W. Jeffries

    2009-01-01

    Response surface methodology was used to evaluate optimal time, temperature and oxalic acid concentration for simultaneous saccharification and fermentation (SSF) of corncob particles by Pichia stipitis CBS 6054. Fifteen different conditions for pretreatment were examined in a 23 full factorial design with six axial points. Temperatures ranged from 132 to 180º...

  15. Understanding the science of climate change: Talking points - Impacts to western mountains and forests

    Treesearch

    Rachel Loehman

    2009-01-01

    Observed climate changes in the Western Mountains and Forests bioregion include increased seasonal, annual, minimum, and maximum temperatures, altered precipitation patterns, and a shift toward earlier timing of peak runoff. These climatic changes have resulted in widespread mortality in western forests, species range shifts and changes in phenology, productivity, and...

  16. Arm and Hand Movement in Children Suspected of Having Autism Spectrum Disorder

    ERIC Educational Resources Information Center

    Braddock, Barbara A.; Hilton, Jane C.

    2016-01-01

    The aim of this study was to describe arm and hand movement in children suspected of having autism spectrum disorder (ASD; age range 29-43 months). A videotaped retrospective review of five children with symptoms of ASD during "Communication Temptation Tasks" was completed at two time points (pre-testing and 6 weeks later). Categories of…

  17. Victimization, Friendship and Resilience: Crossing the Land In-Between

    ERIC Educational Resources Information Center

    Moore, Stephen; MacLean, Rachel

    2012-01-01

    This article explores the victimization of young people immediately before and after the school day. This is a unique time when most young people of secondary school age, from a range of backgrounds, with different interests and standards of behaviour, are constrained to mix at some point on the journey to school. For most young people this a…

  18. UConn Hosts IACLEA for 50th Annual Conference

    ERIC Educational Resources Information Center

    Hudd, Robert S.

    2008-01-01

    The decision that led to the 1992 opening of the University of Connecticut's new public safety complex was excellent timing. Three years after the complex opened, complete with a state-of-the-art Public Safety Answering Point (PSAP), an emergency operations/training center and an indoor firing range, the quiet, nearly 4,000-acre UConn campus…

  19. 40 CFR 463.32 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... finishing water processes at a point source times the following pollutant concentrations: Subpart C [Finishing water] Concentration used to calculate BPT effluent limitations Pollutant or pollutant property Maximum for any 1 day (mg/l) Maximum for monthly average (mg/l) TSS 130 37 pH (1) (1) 1 Within the range...

  20. Elastohydrodynamic lubrication theory

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Dowson, D.

    1982-01-01

    The isothermal elastohydrodynamic lubrication (EHL) of a point contact was analyzed numerically by simultaneously solving the elasticity and Reynolds equations. In the elasticity analysis the contact zone was divided into equal rectangular areas, and it was assumed that a uniform pressure was applied over each area. In the numerical analysis of the Reynolds equation, a phi analysis (where phi is equal to the pressure times the film thickness to the 3/2 power) was used to help the relaxation process. The EHL point contact analysis is applicable for the entire range of elliptical parameters and is valid for any combination of rolling and sliding within the contact.

  1. Fuel Property Determination of Biodiesel-Diesel Blends By Terahertz Spectrum

    NASA Astrophysics Data System (ADS)

    Zhao, Hui; Zhao, Kun; Bao, Rima

    2012-05-01

    The frequency-dependent absorption characteristics of biodiesel and its blends with conventional diesel fuel have been researched in the spectral range of 0.2-1.5 THz by the terahertz time-domain spectroscopy (THz-TDS). The absorption coefficient presented a regular increasing with biodiesel content. A nonlinear multivariate model that correlating cetane number and solidifying point of bio-diesel blends with absorption coefficient has been established, making the quantitative analysis of fuel properties simple. The results made the cetane number and solidifying point prediction possible by THz-TDS technology and indicated a bright future in practical application.

  2. Ranging error analysis of single photon satellite laser altimetry under different terrain conditions

    NASA Astrophysics Data System (ADS)

    Huang, Jiapeng; Li, Guoyuan; Gao, Xiaoming; Wang, Jianmin; Fan, Wenfeng; Zhou, Shihong

    2018-02-01

    Single photon satellite laser altimeter is based on Geiger model, which has the characteristics of small spot, high repetition rate etc. In this paper, for the slope terrain, the distance of error's formula and numerical calculation are carried out. Monte Carlo method is used to simulate the experiment of different terrain measurements. The experimental results show that ranging accuracy is not affected by the spot size under the condition of the flat terrain, But the inclined terrain can influence the ranging error dramatically, when the satellite pointing angle is 0.001° and the terrain slope is about 12°, the ranging error can reach to 0.5m. While the accuracy can't meet the requirement when the slope is more than 70°. Monte Carlo simulation results show that single photon laser altimeter satellite with high repetition rate can improve the ranging accuracy under the condition of complex terrain. In order to ensure repeated observation of the same point for 25 times, according to the parameters of ICESat-2, we deduce the quantitative relation between the footprint size, footprint, and the frequency repetition. The related conclusions can provide reference for the design and demonstration of the domestic single photon laser altimetry satellite.

  3. The modified distal horizontal metatarsal osteotomy for correction of bunionette deformity.

    PubMed

    Radl, Roman; Leithner, Andreas; Koehler, Wolfgang; Scheipl, Susanne; Windhager, Reinhard

    2005-06-01

    Bunionette is a common deformity for which a number of operative procedures have been described. The objective of this study was to evaluate the results of a modified distal horizontal metatarsal osteotomy in the correction of symptomatic bunionette. Metatarsal osteotomies were done in 21 feet in 14 patients (11 females, three males) with an average age of 44 (range 20 to 67) years at the time of operation. The average followup was 32 (range 12 to 52) months. The average Lesser Toe Metatarsophalangeal-Interphalangeal Score of the American Orthopaedic Foot and Ankle Society increased from 42 points (range 24 to 50) preoperatively to 87 points (range 60 to 100) at the last followup. The fifth metatarsophalangeal angle averaged 18 degrees (5 to 38 degrees) preoperatively and 5 degrees (-5 to 26 degrees) at final followup. The 4-5 intermetatarsal angle averaged 14 degrees (10 to 20 degrees) preoperatively and 9 degrees (5 to 12 degrees) at final followup. Hardware was removed from two feet and scheduled for a third foot because of symptomatic skin irritation. The modified distal horizontal metatarsal osteotomy is a stable and reliable method for correction of bunionette. Unsatisfactory results in our patients were related to prominent hardware.

  4. Evaluation of eight short-term long-range transport models using field data

    NASA Astrophysics Data System (ADS)

    Carhart, R. A.; Policastro, A. J.; Wastag, M.; Coke, L.

    Eight short-term long-range transport models (MESOPUFF, MESOPLUME, MSPUFF, MESOPUFF II, MTDDIS, ARRPA, RADM and RTM-II) have been tested with field data from two data bases involving tracer releases. The Oklahoma data base involved two separate experiments with measurements taken at 100 and 600 km arcs downwind of a 3-h perfluorocarbon release. The Savannah River Plant data base encompassed 15 experiments with measurements taken over 2-5 days at distances of 28-144 km downwind from a 62 m stack release of Kr-85 gas. Application of the American Meteorological Society statistics to the model/data comparisons showed that six of the eight models predicted within a factor of two of the observed concentrations for all of the following: points paired in space and time, points paired in space only, and for points unpaired in space and time. However, the ratio of the standard deviation of residuals to the average observed value showed improvement as more unpairing was done in the comparison of the models with the data. The statistical comparisons reveal a definite tendency of the models to overpredict plume concentrations. Supplemental graphical comparisons showed that plume concentration overprediction is accompanied with an underprediction of plume spreading, and that a definite time lag is often observed between the time of arrival of the observed plume and the time of arrival of the predicted plume. The causes of model/data discrepancies can be largely traced to inadequate wind field modeling that leads to an incorrect temporal and spatial positioning of the plume, and the use of the Turner [Workbook of atmospheric dispersion estimates. U.S. Dept of H.E.W. Publication 999-AP-26 (1970)] curves to downwind distances beyond which they can accurately represent the scales of atmospheric turbulence. The use of multilayer wind field models and the use of the Heffter [ J. appl. Met.4, 153-156 (1965)] formula for lateral plume dispersion close to the source appear to improve model accuracies.

  5. Color-magnitude relations in nearby galaxy clusters

    NASA Astrophysics Data System (ADS)

    Rasheed, Mariwan A.; Mohammad, Khalid K.

    2018-06-01

    The rest-frame (g-r) /Mr color-magnitude relations of 12 Abell-type clusters are analyzed in the redshift range (0.02≲ z ≲ 0.10) and within a projected radius of 0.75 Mpc using photometric data from SDSS-DR9. We show that the color-magnitude relation parameters (slope, zero-point, and scatter) do not exhibit significant evolution within this low-redshift range. Thus, we can say that during the look-back time of z ˜ 0.1 all red sequence galaxies evolve passively, without any star formation activity.

  6. Investigation of the Hosgri Fault, offshore Southern California, Point Sal to Point Conception

    USGS Publications Warehouse

    Payne, C.M.; Swanson, O.E.; Schell, B.A.

    1979-01-01

    A high-resolution seismic reflection survey of the inner continental shelf between Point Sal and Point Conception has revealed faults that displace post-Wisconsin strata (less than 17,000-20,000 years). These faults are the Hosgri fault, the Offshore Lompoc fault, and smaller unnamed faults. Faults trending offshore from the adjacent shoreline such as the Pezzoni, Lions Head, Honda, and Pacifico faults, do not show post-Wisconsin activity. The Hosgri fault trends directly toward the coastline between Purisima Point and Point Arguello where it appears to merge with folds and smaller faults in the western Transverse Ranges. This trend of offshore structures toward the Point Arguello-Point Conception area is consistent with a hypothesis that the regional structural fabric of the southern California Coast Ranges and its adjacent offshore area merge with the Transverse Ranges.

  7. MODELING TIME DISPERSION DUE TO OPTICAL PATH LENGTH DIFFERENCES IN SCINTILLATION DETECTORS*

    PubMed Central

    Moses, W.W.; Choong, W.-S.; Derenzo, S.E.

    2015-01-01

    We characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal with 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments. PMID:25729464

  8. Modeling Time Dispersion Due to Optical Path Length Differences in Scintillation Detectors

    DOE PAGES

    Moses, W. W.; Choong, W. -S.; Derenzo, S. E.

    2014-08-20

    In this paper, we characterize the nature of the time dispersion in scintillation detectors caused by path length differences of the scintillation photons as they travel from their generation point to the photodetector. Using Monte Carlo simulation, we find that the initial portion of the distribution (which is the only portion that affects the timing resolution) can usually be modeled by an exponential decay. The peak amplitude and decay time depend both on the geometry of the crystal, the position within the crystal that the scintillation light originates from, and the surface finish. In a rectangular parallelpiped LSO crystal withmore » 3 mm × 3 mm cross section and polished surfaces, the decay time ranges from 10 ps (for interactions 1 mm from the photodetector) up to 80 ps (for interactions 50 mm from the photodetector). Over that same range of distances, the peak amplitude ranges from 100% (defined as the peak amplitude for interactions 1 mm from the photodetector) down to 4% for interactions 50 mm from the photodetector. Higher values for the decay time are obtained for rough surfaces, but the exact value depends on the simulation details. Finally, estimates for the decay time and peak amplitude can be made for different cross section sizes via simple scaling arguments.« less

  9. Application of automatic gain control for radiometer diagnostic in SST-1 tokamak.

    PubMed

    Makwana, Foram R; Siju, Varsha; Edappala, Praveenlal; Pathak, S K

    2017-12-01

    This paper describes the characterisation of a negative feedback type of automatic gain control (AGC) circuit that will be an integral part of the heterodyne radiometer system operating at a frequency range of 75-86 GHz at SST-1 tokamak. The developed AGC circuit is a combination of variable gain amplifier and log amplifier which provides both gain and attenuation typically up to 15 dB and 45 dB, respectively, at a fixed set point voltage and it has been explored for the first time in tokamak radiometry application. The other important characteristics are that it exhibits a very fast response time of 390 ns to understand the fast dynamics of electron cyclotron emission and can operate at very wide input RF power dynamic range of around 60 dB that ensures signal level within the dynamic range of the detection system.

  10. Viscoelastic Response of the Titanium Alloy Ti-6-4: Experimental Identification of Time- and Rate-Dependent Reversible and Irreversible Deformation Regions

    NASA Technical Reports Server (NTRS)

    Lerch, Bradley A.; Arnold, Steven M.

    2014-01-01

    In support of an effort on damage prognosis, the viscoelastic behavior of Ti-6Al-4V (Ti-6-4) was investigated. This report documents the experimental characterization of this titanium alloy. Various uniaxial tests were conducted to low load levels over the temperature range of 20 to 538 C to define tensile, creep, and relaxation behavior. A range of strain rates (6x10(exp -7) to 0.001/s) were used to document rate effects. All tests were designed to include an unloading portion, followed by a hold time at temperature to allow recovery to occur either at zero stress or strain. The titanium alloy was found to exhibit viscoelastic behavior below the "yield" point and over the entire range of temperatures (although at lower temperatures the magnitude is extremely small). These experimental data will be used for future characterization of a viscoelastic model.

  11. Magnetisation studies of phase co-existence in Gd{sub 1-x}Ca{sub x}BaCo{sub 2}O{sub 5.5}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thirumurugan, N.; Bharathi, A., E-mail: bharathi@igcar.gov.in; Arulraj, A.

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer The series Gd{sub 1-x}Ca{sub x}BaCo{sub 2}O{sub 5.5} was synthesised by solid state reaction. Black-Right-Pointing-Pointer Magnetisation studies were carried out in the 4-300 K temperature range in magnetic fields upto 16 Tesla. Black-Right-Pointing-Pointer Results were used to formulate the T versus Ca fraction, phase diagram. Black-Right-Pointing-Pointer Evidence for Magnet-electronic phase separation is shown for the first time in the compound. -- Abstract: Magnetic properties of hole doped, oxygen deficient double perovskite compounds, Gd{sub 1-x}Ca{sub x}BaCo{sub 2}O{sub 5.5}, have been investigated. Ferromagnetic transition temperatures increase and the anti-ferromagnetic transition temperatures decrease with Ca substitution leading to stabilisation of ferromagnetisim formore » x {>=} 0.05. A detailed study of the ferromagnetic phase indicates the presence of double hysterisis loops for Ca fractions, 0.05 {<=} x {<=} 0.2 in the 50-200 K temperature range, suggestive of the co-existence of two ferromagnetic phases with different co-ercivities. Based on the magnetisation and transport measurements a phase diagram is proposed for Ca doped GdBaCo{sub 2}O{sub 5.5}.« less

  12. Impacts of Satellite Orbit and Clock on Real-Time GPS Point and Relative Positioning.

    PubMed

    Shi, Junbo; Wang, Gaojing; Han, Xianquan; Guo, Jiming

    2017-06-12

    Satellite orbit and clock corrections are always treated as known quantities in GPS positioning models. Therefore, any error in the satellite orbit and clock products will probably cause significant consequences for GPS positioning, especially for real-time applications. Currently three types of satellite products have been made available for real-time positioning, including the broadcast ephemeris, the International GNSS Service (IGS) predicted ultra-rapid product, and the real-time product. In this study, these three predicted/real-time satellite orbit and clock products are first evaluated with respect to the post-mission IGS final product, which demonstrates cm to m level orbit accuracies and sub-ns to ns level clock accuracies. Impacts of real-time satellite orbit and clock products on GPS point and relative positioning are then investigated using the P3 and GAMIT software packages, respectively. Numerical results show that the real-time satellite clock corrections affect the point positioning more significantly than the orbit corrections. On the contrary, only the real-time orbit corrections impact the relative positioning. Compared with the positioning solution using the IGS final product with the nominal orbit accuracy of ~2.5 cm, the real-time broadcast ephemeris with ~2 m orbit accuracy provided <2 cm relative positioning error for baselines no longer than 216 km. As for the baselines ranging from 574 to 2982 km, the cm-dm level positioning error was identified for the relative positioning solution using the broadcast ephemeris. The real-time product could result in <5 mm relative positioning accuracy for baselines within 2982 km, slightly better than the predicted ultra-rapid product.

  13. 'How many calories are in my burrito?' Improving consumers' understanding of energy (calorie) range information.

    PubMed

    Liu, Peggy J; Bettman, James R; Uhalde, Arianna R; Ubel, Peter A

    2015-01-01

    Energy (calorie) ranges currently appear on menu boards for customized menu items and will likely appear throughout the USA when menu-labelling legislation is implemented. Consumer welfare advocates have questioned whether energy ranges enable accurate energy estimates. In four studies, we examined: (i) whether energy range information improves energy estimation accuracy; (ii) whether misestimates persist because consumers misinterpret the meaning of the energy range end points; and (iii) whether energy estimates can be made more accurate by providing explicit information about the contents of items at the end points. Four studies were conducted, all randomized experiments. Study 1 took place outside a Chipotle restaurant. Studies 2 to 4 took place online. Participants in study 1 were customers exiting a Chipotle restaurant (n 306). Participants in studies 2 (n 205), 3 (n 290) and 4 (n 874) were from an online panel. Energy ranges reduced energy misestimation across different menu items (studies 1-4). One cause of remaining misestimation was misinterpretation of the low end point's meaning (study 2). Providing explicit information about the contents of menu items associated with energy range end points further reduced energy misestimation (study 3) across different menu items (study 4). Energy range information improved energy estimation accuracy and defining the meaning of the end points further improved accuracy. We suggest that when restaurants present energy range information to consumers, they should explicitly define the meaning of the end points.

  14. SiC/Si diode trigger circuit provides automatic range switching for log amplifier

    NASA Technical Reports Server (NTRS)

    1967-01-01

    SiC/Si diode pair provides automatic range change to extend the operating range of a logarithmic amplifier-conversion circuit and assures stability at or near the range switch-over point. the diode provides hysteresis for a trigger circuit that actuates a relay at the desired range extension point.

  15. Comparative Evaluation of U.S. Brand and Generic Intravenous Sodium Ferric Gluconate Complex in Sucrose Injection: Biodistribution after Intravenous Dosing in Rats

    PubMed Central

    Beekman, Christopher R.; Matta, Murali K.; Thomas, Christopher D.; Mohammad, Adil; Stewart, Sharron; Xu, Lin; Chockalingam, Ashok; Shea, Katherine; Sun, Dajun; Jiang, Wenlei; Patel, Vikram; Rouse, Rodney

    2017-01-01

    Relative biodistribution of FDA-approved innovator and generic sodium ferric gluconate (SFG) drug products was investigated to identify differences in tissue distribution of iron after intravenous dosing to rats. Three equal cohorts of 42 male Sprague-Dawley rats were created with each cohort receiving one of three treatments: (1) the innovator SFG product dosed intravenously at a concentration of 40 mg/kg; (2) the generic SFG product dosed intravenously at a concentration of 40 mg/kg; (3) saline dosed intravenously at equivalent volume to SFG products. Sampling time points were 15 min, 1 h, 8 h, 1 week, two weeks, four weeks, and six weeks post-treatment. Six rats from each group were sacrificed at each time point. Serum, femoral bone marrow, lungs, brain, heart, kidneys, liver, and spleen were harvested and evaluated for total iron concentration by ICP-MS. The ICP-MS analytical method was validated with linearity, range, accuracy, and precision. Results were determined for mean iron concentrations (µg/g) and mean total iron (whole tissue) content (µg/tissue) for each tissue of all groups at each time point. A percent of total distribution to each tissue was calculated for both products. At any given time point, the overall percent iron concentration distribution did not vary between the two SFG drugs by more than 7% in any tissue. Overall, this study demonstrated similar tissue biodistribution for the two SFG products in the examined tissues. PMID:29283393

  16. A Statistical Guide to the Design of Deep Mutational Scanning Experiments.

    PubMed

    Matuszewski, Sebastian; Hildebrandt, Marcel E; Ghenu, Ana-Hermina; Jensen, Jeffrey D; Bank, Claudia

    2016-09-01

    The characterization of the distribution of mutational effects is a key goal in evolutionary biology. Recently developed deep-sequencing approaches allow for accurate and simultaneous estimation of the fitness effects of hundreds of engineered mutations by monitoring their relative abundance across time points in a single bulk competition. Naturally, the achievable resolution of the estimated fitness effects depends on the specific experimental setup, the organism and type of mutations studied, and the sequencing technology utilized, among other factors. By means of analytical approximations and simulations, we provide guidelines for optimizing time-sampled deep-sequencing bulk competition experiments, focusing on the number of mutants, the sequencing depth, and the number of sampled time points. Our analytical results show that sampling more time points together with extending the duration of the experiment improves the achievable precision disproportionately compared with increasing the sequencing depth or reducing the number of competing mutants. Even if the duration of the experiment is fixed, sampling more time points and clustering these at the beginning and the end of the experiment increase experimental power and allow for efficient and precise assessment of the entire range of selection coefficients. Finally, we provide a formula for calculating the 95%-confidence interval for the measurement error estimate, which we implement as an interactive web tool. This allows for quantification of the maximum expected a priori precision of the experimental setup, as well as for a statistical threshold for determining deviations from neutrality for specific selection coefficient estimates. Copyright © 2016 by the Genetics Society of America.

  17. Projection of distributed-collector solar-thermal electric power plant economics to years 1990-2000

    NASA Technical Reports Server (NTRS)

    Fujita, T.; Elgabalawi, N.; Herrera, G.; Turner, R. H.

    1977-01-01

    A preliminary comparative evaluation of distributed-collector solar thermal power plants was undertaken by projecting power plant economics of selected systems to the 1990 to 2000 time frame. The selected systems include: (1) fixed orientation collectors with concentrating reflectors and vacuum tube absorbers, (2) one axis tracking linear concentrator including parabolic trough and variable slat designs, and (3) two axis tracking parabolic dish systems including concepts with small heat engine-electric generator assemblies at each focal point as well as approaches having steam generators at the focal point with pipeline collection to a central power conversion unit. Comparisons are presented primarily in terms of energy cost and capital cost over a wide range of operating load factors. Sensitvity of energy costs for a range of efficiency and cost of major subsystems/components is presented to delineate critical technological development needs.

  18. Perceived time slows during fleeting fun or fear.

    PubMed

    Corke, Mike; Bell, Jason; Goodhew, Stephanie C; Smithson, Michael; Edwards, Mark

    2018-02-01

    Previous psychophysical studies at durations greater than 1000 ms have confirmed the anecdotal reports of an increase in the perceived duration of both positively and negatively valenced emotive stimuli; however, the results of studies at durations less than 1000 ms have been inconsistent. This study further investigated the effect of valence on the perception of durations less than 1000 ms. We used both positively and negatively valenced stimuli in order to compare their effects on the distortion of duration, and we tested multiple data points within the sub-one-second range. We found an increase in the perceived duration of both positively and negatively valenced emotional stimuli at all data points. This is consistent with studies at durations longer than 1000 ms and also with models of temporal processing. We also confirmed that Weber fractions, within the range tested, followed the generalized form of Weber's law.

  19. Modification of the G-phonon mode of graphene by nitrogen doping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lukashev, Pavel V., E-mail: pavel.lukashev@uni.edu; Hurley, Noah; Zhao, Liuyan

    2016-01-25

    The effect of nitrogen doping on the phonon spectra of graphene is analyzed. In particular, we employ first-principles calculations and scanning Raman analysis to investigate the dependence of phonon frequencies in graphene on the concentration of nitrogen dopants. We demonstrate that the G phonon frequency shows oscillatory behavior as a function of nitrogen concentration. We analyze different mechanisms which could potentially be responsible for this behavior, such as Friedel charge oscillations around the localized nitrogen impurity atom, the bond length change between nitrogen impurity and its nearest neighbor carbon atoms, and the long-range interactions of the nitrogen point defects. Wemore » show that the bond length change and the long range interaction of point defects are possible mechanisms responsible for the oscillatory behavior of the G frequency as a function of nitrogen concentration. At the same time, Friedel charge oscillations are unlikely to contribute to this behavior.« less

  20. LAMMPS strong scaling performance optimization on Blue Gene/Q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coffman, Paul; Jiang, Wei; Romero, Nichols A.

    2014-11-12

    LAMMPS "Large-scale Atomic/Molecular Massively Parallel Simulator" is an open-source molecular dynamics package from Sandia National Laboratories. Significant performance improvements in strong-scaling and time-to-solution for this application on IBM's Blue Gene/Q have been achieved through computational optimizations of the OpenMP versions of the short-range Lennard-Jones term of the CHARMM force field and the long-range Coulombic interaction implemented with the PPPM (particle-particle-particle mesh) algorithm, enhanced by runtime parameter settings controlling thread utilization. Additionally, MPI communication performance improvements were made to the PPPM calculation by re-engineering the parallel 3D FFT to use MPICH collectives instead of point-to-point. Performance testing was done using anmore » 8.4-million atom simulation scaling up to 16 racks on the Mira system at Argonne Leadership Computing Facility (ALCF). Speedups resulting from this effort were in some cases over 2x.« less

  1. Air and Space Power Journal. Volume 23, Number 1, Spring 2009

    DTIC Science & Technology

    2009-01-01

    only current, applicable scenarios for robust counterspace operations. even in the most vivid dreams of such advocates, the development of space...carry a 10,000-pound atomic bomb out to an ap­ preciable range. At the time, few dreamed that nukes would soon shrink to the point that a standard...from the local one. Overall, both volumes of Beyond al-Qaeda are valuable. Rabasa’s lucid and timely analysis has im­ plications for the defense

  2. Fast Fractional Cascading and Its Applications

    DTIC Science & Technology

    2003-08-01

    the list associated with a tree node will require O(log log n)time, which negates the e ect of the \\fattened" tree. Only in some special cases, such...2]) in constant time, we have shown in [21] that we can handle theso-called 3-sided two dimensional range queries e ciently. Brie y, a point (a; b...which, when modi edappropriately, can be used to handle the orthogonal segment intersection problem e ciently.His modi cation of the vertical adjacency

  3. The pointing errors of geosynchronous satellites

    NASA Technical Reports Server (NTRS)

    Sikdar, D. N.; Das, A.

    1971-01-01

    A study of the correlation between cloud motion and wind field was initiated. Cloud heights and displacements were being obtained from a ceilometer and movie pictures, while winds were measured from pilot balloon observations on a near-simultaneous basis. Cloud motion vectors were obtained from time-lapse cloud pictures, using the WINDCO program, for 27, 28 July, 1969, in the Atlantic. The relationship between observed features of cloud clusters and the ambient wind field derived from cloud trajectories on a wide range of space and time scales is discussed.

  4. Performance of an extended dynamic range time delay integration charge coupled device (XDR TDI CCD) for high-intrascene dynamic range scanning

    NASA Astrophysics Data System (ADS)

    Levine, Peter A.; Dawson, Robin M.; Andrews, James T.; Bhaskaran, Mahalingham; Furst, David; Hsueh, Fu-Lung; Meray, Grazyna M.; Sudol, Thomas M.; Swain, Pradyumna K.; Tower, John R.

    2003-05-01

    Many applications, such as industrial inspection and overhead reconnaissance benefit from line scanning architectures where time delay integration (TDI) significantly improves sensitivity. CCDs are particularly well suited to the TDI architecture since charge is transferred virtually noiselessly down the column. Sarnoff's TDI CCDs have demonstrated extremely high speeds where a 7200 x 64, 8 um pixel device with 120 output ports demonstrated a vertical line transfer rate greater than 800 kHz. The most recent addition to Sarnoff's TDI technology is the implementation of extended dynamic range (XDR) in high speed, back illuminated TDI CCDs. The optical, intrascene dynamic range can be adjusted in the design of the imager with measured dynamic ranges exceeding 2,000,000:1 with no degradation in low light performance. The device provides a piecewise linear response to light where multiple slopes and break points can be set during the CCD design. A description of the device architecture and measured results from fabricated XDR TDI CCDs are presented.

  5. Evaluation of Parameter Uncertainty Reduction in Groundwater Flow Modeling Using Multiple Environmental Tracers

    NASA Astrophysics Data System (ADS)

    Arnold, B. W.; Gardner, P.

    2013-12-01

    Calibration of groundwater flow models for the purpose of evaluating flow and aquifer heterogeneity typically uses observations of hydraulic head in wells and appropriate boundary conditions. Environmental tracers have a wide variety of decay rates and input signals in recharge, resulting in a potentially broad source of additional information to constrain flow rates and heterogeneity. A numerical study was conducted to evaluate the reduction in uncertainty during model calibration using observations of various environmental tracers and combinations of tracers. A synthetic data set was constructed by simulating steady groundwater flow and transient tracer transport in a high-resolution, 2-D aquifer with heterogeneous permeability and porosity using the PFLOTRAN software code. Data on pressure and tracer concentration were extracted at well locations and then used as observations for automated calibration of a flow and transport model using the pilot point method and the PEST code. Optimization runs were performed to estimate parameter values of permeability at 30 pilot points in the model domain for cases using 42 observations of: 1) pressure, 2) pressure and CFC11 concentrations, 3) pressure and Ar-39 concentrations, and 4) pressure, CFC11, Ar-39, tritium, and He-3 concentrations. Results show significantly lower uncertainty, as indicated by the 95% linear confidence intervals, in permeability values at the pilot points for cases including observations of environmental tracer concentrations. The average linear uncertainty range for permeability at the pilot points using pressure observations alone is 4.6 orders of magnitude, using pressure and CFC11 concentrations is 1.6 orders of magnitude, using pressure and Ar-39 concentrations is 0.9 order of magnitude, and using pressure, CFC11, Ar-39, tritium, and He-3 concentrations is 1.0 order of magnitude. Data on Ar-39 concentrations result in the greatest parameter uncertainty reduction because its half-life of 269 years is similar to the range of transport times (hundreds to thousands of years) in the heterogeneous synthetic aquifer domain. The slightly higher uncertainty range for the case using all of the environmental tracers simultaneously is probably due to structural errors in the model introduced by the pilot point regularization scheme. It is concluded that maximum information and uncertainty reduction for constraining a groundwater flow model is obtained using an environmental tracer whose half-life is well matched to the range of transport times through the groundwater flow system. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  6. Time delays in flight simulator visual displays

    NASA Technical Reports Server (NTRS)

    Crane, D. F.

    1980-01-01

    It is pointed out that the effects of delays of less than 100 msec in visual displays on pilot dynamic response and system performance are of particular interest at this time because improvements in the latest computer-generated imagery (CGI) systems are expected to reduce CGI displays delays to this range. Attention is given to data which quantify the effects of display delays in the range of 0-100 msec on system stability and performance, and pilot dynamic response for a particular choice of aircraft dynamics, display, controller, and task. The conventional control system design methods are reviewed, the pilot response data presented, and data for long delays, all suggest lead filter compensation of display delay. Pilot-aircraft system crossover frequency information guides compensation filter specification.

  7. Treatment of distal-third clavicular fractures (Neer type ii-b) with a triple button device.

    PubMed

    Cano-Martínez, J A; Nicolás-Serrano, G; Andrés-Grau, J; Bento-Gerard, J

    The purpose of this study is to describe the outcomes of using a triple button device for the treatment of displaced distal-third clavicle fractures (Neer, type ii-b). A retrospective review was conducted on a series of patients between November 2011 and December 2014. Fourteen patients initially met the inclusion criteria, but 2 were excluded, leaving 12 patients (83.3% male; mean age 32.2 years) for the final analysis at a mean follow-up of 26±11.24 months (range, 12-48). Post-operative follow-up was performed at 2 weeks (two first months), and monthly thereafter, until was achieving clinically and radiological healing. The functional outcome was evaluated using the Constant score, and DASH score in the last follow-up. The mean Constant Score was 95.5±5.2 points (range, 85-100), with a mean DASH score of 3.3±4.4 points (range, 0-12.5). The mean time to clinical healing was10.3±3.1 weeks (range, 8-16), and the mean time to radiological healing was 13.6±2.6 weeks (range, 12-20). There were no major complications. There were 5 minor complications without clinical impact: 2 coracoclavicular calcifications, 1 hypertrophic scar, 1 patient with discomfort due to the device, and 1 superficial wound infection. All patients returned their previous activity. Good clinical results can be achieved with the triple button device in unstable distal fractures of the clavicle, without the need to remove the hardware. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. How to successfully implement a robotic pediatric surgery program: lessons learned after 96 procedures.

    PubMed

    de Lambert, Guénolée; Fourcade, Laurent; Centi, Joachim; Fredon, Fabien; Braik, Karim; Szwarc, Caroline; Longis, Bernard; Lardy, Hubert

    2013-06-01

    Both our teams were the first to implement pediatric robotic surgery in France. The aim of this study was to define the key points we brought to light so other pediatric teams that want to set up a robotic surgery program will benefit. We reviewed the medical records of all children who underwent robotic surgery between Nov 2007 and June 2011 in both departments, including patient data, installation and changes, operative time, hospital stay, intraoperative complications, and postoperative outcome. The department's internal organization, the organization within the hospital complex, and cost were evaluated. A total of 96 procedures were evaluated. There were 38 girls and 56 boys with average age at surgery of 7.6 years (range, 0.7-18 years) and average weight of 26 kg (range, 6-77 kg). Thirty-six patients had general surgery, 57 patients urologic surgery, and 1 thoracic surgery. Overall average operative time was 189 min (range, 70-550 min), and average hospital stay was 6.4 days (range, 2-24 days). The procedures of 3 patients were converted. Median follow-up was 18 months (range, 0.5-43 months). Robotic surgical procedure had an extra cost of 1934 compared to conventional open surgery. Our experience was similar to the findings described in the literature for feasibility, security, and patient outcomes; we had an overall operative success rate of 97 %. Three main actors are concerned in the implementation of a robotic pediatric surgery program: surgeons and anesthetists, nurses, and the administration. The surgeon is at the starting point with motivation for minimally invasive surgery without laparoscopic constraints. We found that it was possible to implement a long-lasting robotic surgery program with comparable quality of care.

  9. Investigation of the Parameters of Sealed Triple-Point Cells for Cryogenic Gases

    NASA Astrophysics Data System (ADS)

    Fellmuth, B.; Wolber, L.

    2011-01-01

    An overview of the parameters of a large number of sealed triple-point cells for the cryogenic gases hydrogen, oxygen, neon, and argon is given that have been determined within the framework of an international star intercomparison to optimize the measurement of melting curves as well as to establish complete and reliable uncertainty budgets for the realization of temperature fixed points. Special emphasis is given to the question, whether the parameters are primarily influenced by the cell design or the properties of the fixed-point samples. For explaining surprisingly large periods of the thermal recovery after the heat pulses of the intermittent heating through the melting range, a simple model is developed based on a newly defined heat-capacity equivalent, which considers the heat of fusion and a melting-temperature inhomogeneity. The analysis of the recovery using a graded set of exponential functions containing different time constants is also explained in detail.

  10. Relationship between team assists and win-loss record in The National Basketball Association.

    PubMed

    Melnick, M J

    2001-04-01

    Using research methodology for analysis of secondary data, statistical data for five National Basketball Association (NBA) seasons (1993-1994 to 1997-1998) were examined to test for a relationship between team assists (a behavioral measure of teamwork) and win-loss record. Rank-difference correlation indicated a significant relationship between the two variables, the coefficients ranging from .42 to .71. Team assist totals produced higher correlations with win-loss record than assist totals for the five players receiving the most playing time ("the starters"). A comparison of "assisted team points" and "unassisted team points" in relationship to win-loss record favored the former and strongly suggested that how a basketball team scores points is more important than the number of points it scores. These findings provide circumstantial support for the popular dictum in competitive team sports that "Teamwork Means Success-Work Together, Win Together."

  11. Hydronephrosis in patients with cervical cancer: an assessment of morbidity and survival.

    PubMed

    Patel, Krishna; Foster, Nathan R; Kumar, Amanika; Grudem, Megan; Longenbach, Sherri; Bakkum-Gamez, Jamie; Haddock, Michael; Dowdy, Sean; Jatoi, Aminah

    2015-05-01

    Hydronephrosis is a frequently observed but understudied complication in patients with cervical cancer. To better characterize hydronephrosis in cervical cancer patients, the current study sought (1) to describe hydronephrosis-associated morbidity and (2) to analyze the prognostic effect of hydronephrosis in patients with a broad range of cancer stages over time. The Mayo Clinic Tumor Registry was interrogated for all invasive cervical cancer patients seen at the Mayo Clinic from 2008 through 2013 in Rochester, Minnesota; these patients' medical records were then reviewed in detail. Two hundred seventy-nine cervical cancer patients with a median age of 49 years and a range of cancer stages were included. Sixty-five patients (23 %) were diagnosed with hydronephrosis at some point during their disease course. In univariate analyses, hydronephrosis was associated with advanced cancer stage (p < 0.0001), squamous histology (p = 0.0079), and nonsurgical cancer treatment (p = 0.0039). In multivariate analyses, stage and tumor histology were associated with hydronephrosis. All but one patient underwent stent placement or urinary diversion; hydronephrosis-related morbidity included pain, urinary tract infections, nausea and vomiting, renal failure, and urinary tract bleeding. In landmark univariate survival analyses, hydronephrosis was associated with worse survival at all time points. In landmark multivariate analyses (adjusted for patient age, stage, cancer treatment, and tumor histology), hydronephrosis was associated with a trend toward worse survival over time (hazard ratios ranged from 1.47 to 4.69). Hydronephrosis in cervical cancer patients is associated with notable morbidity. It is also associated with trends toward worse survival-even if it occurs after the original cancer diagnosis.

  12. A point-of-care chemistry test for reduction of turnaround and clinical decision time.

    PubMed

    Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul

    2011-06-01

    Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P < .0001). The median (IQR) door-to-clinical-decision time was also shorter in the POCT compared with the CLT group (46, 33-61 versus 86, 68-107 minutes; P < .0001). The proportion of patients who had new decisions within 60 minutes was 72.8% for the POCT group and 12.5% for the CLT group (P < .0001). A POCT chemistry analyzer in the ED shortens the test turnaround and ED clinical decision times compared with CLT. Copyright © 2011 Elsevier Inc. All rights reserved.

  13. Longitudinal Associations Among Bullying by Peers, Disordered Eating Behavior, and Symptoms of Depression During Adolescence.

    PubMed

    Lee, Kirsty S; Vaillancourt, Tracy

    2018-06-01

    Bullying by peers has been associated with disordered eating behavior and symptoms of depression among adolescents as both an antecedent and an outcome. Identification of the temporal pattern of associations among bullying by peers, disordered eating behavior, and depression in adolescence is needed for the optimal targeting of intervention and prevention. To assess the concurrent and longitudinal associations among bullying by peers, disordered eating behavior, and symptoms of depression using a cascade model that controlled for within-time and across-time (ie, stability paths) associations while examining cross-lag effects. In this 5-year longitudinal cohort study, 612 participants of the McMaster Teen Study were included. This ongoing Canadian study examines the associations among bullying, mental health, and educational outcomes. Data collection began in 2008 when students were in grade 5 (10 years of age) and have since been collected annually. Data analysis was performed between August 20 and October 18, 2017. Bullying by peers was assessed in grades 7 to 11 using a composite measure of 5 items. Disordered eating behavior was assessed in grades 7 to 11 using the Short Screen for Eating Disorders, and depressive symptoms were assessed in grades 7 to 11 using the Behavior Assessment System for Children-Second Edition. The 612 students included in the analytic sample had a mean age (SD) of 13.03 (0.38) years in grade 7; 331 (54.1%) were girls and 392 (71.1%) were white. Bullying by peers was concurrently associated with disordered eating behavior and depressive symptoms at every time point during the 5-year period (r range [SE], 0.15-0.48 [0.04-0.08]; P < .01). Disordered eating behavior was associated longitudinally with depressive symptoms at every time point (β range [SE], 0.14-0.19 [0.06-0.08]; P < .02) and bullying by peers at 2 time points (β range [SE], 0.12-0.22 [0.06-0.07]; P < .04) in girls and boys. Bullying by peers was proximally associated with multiple psychopathologic symptoms, whereas symptoms of disordered eating behavior were a key risk factor for future depressive symptoms and bullying by peers. Interventions aimed at reducing problematic eating behavior in adolescents may attenuate the risk of future depressive symptoms and relational problems.

  14. Two-point correlation functions in inhomogeneous and anisotropic cosmologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marcori, Oton H.; Pereira, Thiago S., E-mail: otonhm@hotmail.com, E-mail: tspereira@uel.br

    Two-point correlation functions are ubiquitous tools of modern cosmology, appearing in disparate topics ranging from cosmological inflation to late-time astrophysics. When the background spacetime is maximally symmetric, invariance arguments can be used to fix the functional dependence of this function as the invariant distance between any two points. In this paper we introduce a novel formalism which fixes this functional dependence directly from the isometries of the background metric, thus allowing one to quickly assess the overall features of Gaussian correlators without resorting to the full machinery of perturbation theory. As an application we construct the CMB temperature correlation functionmore » in one inhomogeneous (namely, an off-center LTB model) and two spatially flat and anisotropic (Bianchi) universes, and derive their covariance matrices in the limit of almost Friedmannian symmetry. We show how the method can be extended to arbitrary N -point correlation functions and illustrate its use by constructing three-point correlation functions in some simple geometries.« less

  15. Effect of home testing of international normalized ratio on clinical events.

    PubMed

    Matchar, David B; Jacobson, Alan; Dolor, Rowena; Edson, Robert; Uyeda, Lauren; Phibbs, Ciaran S; Vertrees, Julia E; Shih, Mei-Chiung; Holodniy, Mark; Lavori, Philip

    2010-10-21

    Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).

  16. Development and validation of a fast and simple multi-analyte procedure for quantification of 40 drugs relevant to emergency toxicology using GC-MS and one-point calibration.

    PubMed

    Meyer, Golo M J; Weber, Armin A; Maurer, Hans H

    2014-05-01

    Diagnosis and prognosis of poisonings should be confirmed by comprehensive screening and reliable quantification of xenobiotics, for example by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS). The turnaround time should be short enough to have an impact on clinical decisions. In emergency toxicology, quantification using full-scan acquisition is preferable because this allows screening and quantification of expected and unexpected drugs in one run. Therefore, a multi-analyte full-scan GC-MS approach was developed and validated with liquid-liquid extraction and one-point calibration for quantification of 40 drugs relevant to emergency toxicology. Validation showed that 36 drugs could be determined quickly, accurately, and reliably in the range of upper therapeutic to toxic concentrations. Daily one-point calibration with calibrators stored for up to four weeks reduced workload and turn-around time to less than 1 h. In summary, the multi-analyte approach with simple liquid-liquid extraction, GC-MS identification, and quantification over fast one-point calibration could successfully be applied to proficiency tests and real case samples. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Brute Force Matching Between Camera Shots and Synthetic Images from Point Clouds

    NASA Astrophysics Data System (ADS)

    Boerner, R.; Kröhnert, M.

    2016-06-01

    3D point clouds, acquired by state-of-the-art terrestrial laser scanning techniques (TLS), provide spatial information about accuracies up to several millimetres. Unfortunately, common TLS data has no spectral information about the covered scene. However, the matching of TLS data with images is important for monoplotting purposes and point cloud colouration. Well-established methods solve this issue by matching of close range images and point cloud data by fitting optical camera systems on top of laser scanners or rather using ground control points. The approach addressed in this paper aims for the matching of 2D image and 3D point cloud data from a freely moving camera within an environment covered by a large 3D point cloud, e.g. a 3D city model. The key advantage of the free movement affects augmented reality applications or real time measurements. Therefore, a so-called real image, captured by a smartphone camera, has to be matched with a so-called synthetic image which consists of reverse projected 3D point cloud data to a synthetic projection centre whose exterior orientation parameters match the parameters of the image, assuming an ideal distortion free camera.

  18. The Apache Point Observatory Lunar Laser-ranging Operation: Instrument Description and First Detections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, TW; Adelberger, Eric G.; Battat, J.

    2008-01-01

    A next-generation lunar laser ranging apparatus using the 3.5 m telescope at the Apache Point Observatory in southern New Mexico has begun science operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation) has achieved one-millimeter range precision to the moon which should lead to aproximately one-orderof-magnitude improvements in the precision of several tests of fundamental properties of gravity. We briefly motivate the scientific goals, and then give a detailed discussion of the APOLLO instrumentation.

  19. Brightness and magnetic evolution of solar coronal bright points

    NASA Astrophysics Data System (ADS)

    Ugarte-Urra, I.

    2004-12-01

    This thesis presents a study of the brightness and magnetic evolution of several Extreme ultraviolet (EUV) coronal bright points (hereafter BPs). BPs are loop-like features of enhanced emission in the coronal EUV and X-ray images of the Sun, that are associated to the interaction of opposite photospheric magnetic polarities with magnetic fluxes of ≈1018 - 1019 Mx. The study was carried out using several instruments on board the Solar and Heliospheric Observatory (SOHO): the Extreme Ultraviolet Imager (EIT), the Coronal Diagnostic Spectrometer (CDS) and the Michelson Doppler Imager (MDI), supported by the high resolution imaging from the Transition Region And Coronal Explorer (TRACE). The results confirm that, down to 1'' (i.e. ~715 km) resolution, BPs are made of small loops with lengths of ~6 Mm and cross-sections of ~2 Mm. The loops are very dynamic, evolving in time scales as short as 1 - 2 minutes. This is reflected in a highly variable EUV response with fluctuations highly correlated in spectral lines at transition region temperatures (in the range 3.2x10^4 - 3.5x10^5 K), but not always at coronal temperatures. A wavelet analysis of the intensity variations reveals, for the first time, the existence of quasi-periodic oscillations with periods ranging 400 -- 1000 s, in the range of periods characteristic of the chromospheric network. The link between BPs and network bright points is discussed, as well as the interpretation of the oscillations in terms of global acoustic modes of closed magnetic structures. A comparison of the magnetic flux evolution of the magnetic polarities to the EUV flux changes is also presented. Throughout their lifetime, the intrinsic EUV emission of BPs is found to be dependent on the total magnetic flux of the polarities. In short time scales, co-spatial and co-temporal TRACE and MDI images, reveal the signature of heating events that produce sudden EUV brightenings simultaneous to magnetic flux cancellations. This is interpreted in terms of magnetic reconnection events. Finally, a electron density study of six coronal bright points produces values of ~1.6x109 cm-3, closer to active region plasma than to quiet Sun. The analysis of a large coronal loop (half length of 72 Mm) introduces the discussion on the prospects of future plasma diagnostics of BPs with forthcoming solar missions like Solar-B.

  20. Singularities of Floquet scattering and tunneling

    NASA Astrophysics Data System (ADS)

    Landa, H.

    2018-04-01

    We study quasibound states and scattering with short-range potentials in three dimensions, subject to an axial periodic driving. We find that poles of the scattering S matrix can cross the real energy axis as a function of the drive amplitude, making the S matrix nonanalytic at a singular point. For the corresponding quasibound states that can tunnel out of (or get captured within) a potential well, this results in a discontinuous jump in both the angular momentum and energy of emitted (absorbed) waves. We also analyze elastic and inelastic scattering of slow particles in the time-dependent potential. For a drive amplitude at the singular point, there is a total absorption of incoming low-energy (s wave) particles and their conversion to high-energy outgoing (mostly p ) waves. We examine the relation of such Floquet singularities, lacking in an effective time-independent approximation, with well-known "spectral singularities" (or "exceptional points"). These results are based on an analytic approach for obtaining eigensolutions of time-dependent periodic Hamiltonians with mixed cylindrical and spherical symmetry, and apply broadly to particles interacting via power-law forces and subject to periodic fields, e.g., co-trapped ions and atoms.

  1. The Charge Transfer Efficiency and Calibration of WFPC2

    NASA Technical Reports Server (NTRS)

    Dolphin, Andrew E.

    2000-01-01

    A new determination of WFPC2 photometric corrections is presented, using HSTphot reduction of the WFPC2 Omega Centauri and NGC 2419 observations from January 1994 through March 2000 and a comparison with ground-based photometry. No evidence is seen for any position-independent photometric offsets (the "long-short anomaly"); all systematic errors appear to be corrected with the CTE and zero point solution. The CTE loss time dependence is determined to be very significant in the Y direction, causing time-independent CTE solutions to be valid only for a small range of times. On average, the present solution produces corrections similar to Whitmore, Heyer, & Casertano, although with an improved functional form that produces less scatter in the residuals and determined with roughly a year of additional data. In addition to the CTE loss characterization, zero point corrections are also determined as functions of chip, gain, filter, and temperature. Of interest, there are chip-to-chip differences of order 0.01 - 0.02 magnitudes relative to the Holtzman et al. calibrations, and the present study provides empirical zero point determinations for the non-standard filters such as the frequently-used F450W, F606W, and F702W.

  2. Terrain modeling for real-time simulation

    NASA Astrophysics Data System (ADS)

    Devarajan, Venkat; McArthur, Donald E.

    1993-10-01

    There are many applications, such as pilot training, mission rehearsal, and hardware-in-the- loop simulation, which require the generation of realistic images of terrain and man-made objects in real-time. One approach to meeting this requirement is to drape photo-texture over a planar polygon model of the terrain. The real time system then computes, for each pixel of the output image, the address in a texture map based on the intersection of the line-of-sight vector with the terrain model. High quality image generation requires that the terrain be modeled with a fine mesh of polygons while hardware costs limit the number of polygons which may be displayed for each scene. The trade-off between these conflicting requirements must be made in real-time because it depends on the changing position and orientation of the pilot's eye point or simulated sensor. The traditional approach is to develop a data base consisting of multiple levels of detail (LOD), and then selecting for display LODs as a function of range. This approach could lead to both anomalies in the displayed scene and inefficient use of resources. An approach has been developed in which the terrain is modeled with a set of nested polygons and organized as a tree with each node corresponding to a polygon. This tree is pruned to select the optimum set of nodes for each eye-point position. As the point of view moves, the visibility of some nodes drops below the limit of perception and may be deleted while new points must be added in regions near the eye point. An analytical model has been developed to determine the number of polygons required for display. This model leads to quantitative performance measures of the triangulation algorithm which is useful for optimizing system performance with a limited display capability.

  3. Curvature-correction-based time-domain CMOS smart temperature sensor with an inaccuracy of -0.8 °C-1.2 °C after one-point calibration from -40 °C to 120 °C

    NASA Astrophysics Data System (ADS)

    Chen, Chun-Chi; Lin, Shih-Hao; Lin, Yi

    2014-06-01

    This paper proposes a time-domain CMOS smart temperature sensor featuring on-chip curvature correction and one-point calibration support for thermal management systems. Time-domain inverter-based temperature sensors, which exhibit the advantages of low power and low cost, have been proposed for on-chip thermal monitoring. However, the curvature is large for the thermal transfer curve, which substantially affects the accuracy as the temperature range increases. Another problem is that the inverter is sensitive to process variations, resulting in difficulty for the sensors to achieve an acceptable accuracy for one-point calibration. To overcome these two problems, a temperature-dependent oscillator with curvature correction is proposed to increase the linearity of the oscillatory width, thereby resolving the drawback caused by a costly off-chip second-order master curve fitting. For one-point calibration support, an adjustable-gain time amplifier was adopted to eliminate the effect of process variations, with the assistance of a calibration circuit. The proposed circuit occupied a small area of 0.073 mm2 and was fabricated in a TSMC CMOS 0.35-μm 2P4M digital process. The linearization of the oscillator and the effect cancellation of process variations enabled the sensor, which featured a fixed resolution of 0.049 °C/LSB, to achieve an optimal inaccuracy of -0.8 °C to 1.2 °C after one-point calibration of 12 test chips from -40 °C to 120 °C. The power consumption was 35 μW at a sample rate of 10 samples/s.

  4. Validation of accelerometer cut points in toddlers with and without cerebral palsy.

    PubMed

    Oftedal, Stina; Bell, Kristie L; Davies, Peter S W; Ware, Robert S; Boyd, Roslyn N

    2014-09-01

    The purpose of this study was to validate uni- and triaxial ActiGraph cut points for sedentary time in toddlers with cerebral palsy (CP) and typically developing children (TDC). Children (n = 103, 61 boys, mean age = 2 yr, SD = 6 months, range = 1 yr 6 months-3 yr) were divided into calibration (n = 65) and validation (n = 38) samples with separate analyses for TDC (n = 28) and ambulant (Gross Motor Function Classification System I-III, n = 51) and nonambulant (Gross Motor Function Classification System IV-V, n = 25) children with CP. An ActiGraph was worn during a videotaped assessment. Behavior was coded as sedentary or nonsedentary. Receiver operating characteristic-area under the curve analysis determined the classification accuracy of accelerometer data. Predictive validity was determined using the Bland-Altman analysis. Classification accuracy for uniaxial data was fair for the ambulatory CP and TDC group but poor for the nonambulatory CP group. Triaxial data showed good classification accuracy for all groups. The uniaxial ambulatory CP and TDC cut points significantly overestimated sedentary time (bias = -10.5%, 95% limits of agreement [LoA] = -30.2% to 9.1%; bias = -17.3%, 95% LoA = -44.3% to 8.3%). The triaxial ambulatory and nonambulatory CP and TDC cut points provided accurate group-level measures of sedentary time (bias = -1.5%, 95% LoA = -20% to 16.8%; bias = 2.1%, 95% LoA = -17.3% to 21.5%; bias = -5.1%, 95% LoA = -27.5% to 16.1%). Triaxial accelerometers provide useful group-level measures of sedentary time in children with CP across the spectrum of functional abilities and TDC. Uniaxial cut points are not recommended.

  5. A multi points ultrasonic detection method for material flow of belt conveyor

    NASA Astrophysics Data System (ADS)

    Zhang, Li; He, Rongjun

    2018-03-01

    For big detection error of single point ultrasonic ranging technology used in material flow detection of belt conveyor when coal distributes unevenly or is large, a material flow detection method of belt conveyor is designed based on multi points ultrasonic counter ranging technology. The method can calculate approximate sectional area of material by locating multi points on surfaces of material and belt, in order to get material flow according to running speed of belt conveyor. The test results show that the method has smaller detection error than single point ultrasonic ranging technology under the condition of big coal with uneven distribution.

  6. 33 CFR 334.1120 - Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. 334.1120 Section 334.1120 Navigation and Navigable... REGULATIONS § 334.1120 Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. (a...

  7. 33 CFR 334.1120 - Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. 334.1120 Section 334.1120 Navigation and Navigable... REGULATIONS § 334.1120 Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. (a...

  8. 33 CFR 334.1120 - Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. 334.1120 Section 334.1120 Navigation and Navigable... REGULATIONS § 334.1120 Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. (a...

  9. 33 CFR 334.1120 - Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. 334.1120 Section 334.1120 Navigation and Navigable... REGULATIONS § 334.1120 Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. (a...

  10. 33 CFR 334.1120 - Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. 334.1120 Section 334.1120 Navigation and Navigable... REGULATIONS § 334.1120 Pacific Ocean in the vicinity of Point Mugu, Calif.; naval small arms firing range. (a...

  11. The Relationship between OCT-measured Central Retinal Thickness and Visual Acuity in Diabetic Macular Edema

    PubMed Central

    2008-01-01

    Objective To compare optical coherence tomography (OCT)-measured retinal thickness and visual acuity in eyes with diabetic macular edema (DME) both before and after macular laser photocoagulation. Design Cross-sectional and longitudinal study. Participants 210 subjects (251 eyes) with DME enrolled in a randomized clinical trial of laser techniques. Methods Retinal thickness was measured with OCT and visual acuity was measured with the electronic-ETDRS procedure. Main Outcome Measures OCT-measured center point thickness and visual acuity Results The correlation coefficients for visual acuity versus OCT center point thickness were 0.52 at baseline and 0.49, 0.36, and 0.38 at 3.5, 8, and 12 months post-laser photocoagulation. The slope of the best fit line to the baseline data was approximately 4.4 letters (95% C.I.: 3.5, 5.3) better visual acuity for every 100 microns decrease in center point thickness at baseline with no important difference at follow-up visits. Approximately one-third of the variation in visual acuity could be predicted by a linear regression model that incorporated OCT center point thickness, age, hemoglobin A1C, and severity of fluorescein leakage in the center and inner subfields. The correlation between change in visual acuity and change in OCT center point thickening 3.5 months after laser treatment was 0.44 with no important difference at the other follow-up times. A subset of eyes showed paradoxical improvements in visual acuity with increased center point thickening (7–17% at the three time points) or paradoxical worsening of visual acuity with a decrease in center point thickening (18%–26% at the three time points). Conclusions There is modest correlation between OCT-measured center point thickness and visual acuity, and modest correlation of changes in retinal thickening and visual acuity following focal laser treatment for DME. However, a wide range of visual acuity may be observed for a given degree of retinal edema and paradoxical increases in center point thickening with increases in visual acuity as well as paradoxical decreases in center point thickening with decreases in visual acuity were not uncommon. Thus, although OCT measurements of retinal thickness represent an important tool in clinical evaluation, they cannot reliably substitute as a surrogate for visual acuity at a given point in time. This study does not address whether short-term changes on OCT are predictive of long-term effects on visual acuity. PMID:17123615

  12. A comparison of outcomes between a lumen-apposing metal stent with electrocautery-enhanced delivery system and a bi-flanged metal stent for drainage of walled-off pancreatic necrosis.

    PubMed

    Bekkali, Noor L H; Nayar, Manu K; Leeds, John S; Charnley, Richard M; Huggett, Matthew T; Oppong, Kofi W

    2017-12-01

     Bi-flanged metal stents (BFMS) have shown promise in the drainage of walled-off pancreatic necrosis (WON), but their placement requires multiple steps and the use of other devices. More recently, a novel device consisting of a combined lumen-apposing metal stent (LAMS) and electrocautery-enhanced delivery system has been introduced. The aim of this study was to compare the placement and outcomes of the two devices.  This was a retrospective review of consecutive patients undergoing endoscopic ultrasound-guided placement of BFMS or LAMS for drainage of symptomatic WON. Data from procedures between October 2012 and December 2016 were taken from a prospectively maintained database. We compared technical and clinical success, procedure time, costs, and composite end point of significant events (adverse events, stent migration, additional percutaneous drainage) between BFMS and LAMS.  72 consecutive patients underwent placement of BFMS (40 patients, 44 stents) or LAMS (32 patients, 33 stents). Technical success was 91 % for BFMS and 97 % for LAMS. Clinical success was 65 % vs. 78 %, respectively. Median in-room procedure time was significantly shorter in the LAMS group (45 minutes [range 30 - 80]) than in the BFMS group (62.5 minutes [range 35 - 135]; P  < 0.001) and fewer direct endoscopic necrosectomies (DEN) were performed (median 1 [0 - 2.0] vs. 2 [0 - 3.7], respectively; P  = 0.005). If only inpatients were considered (35 BFMS and 19 LAMS), there was no significant difference in DEN 2 (range 0 - 11) and 2 (range 0 - 8), respectively. The composite end point of 32 % vs. 24 % was not significantly different. Median procedural costs for all patients with successful stent placement for WON treatment was €4427 (range 1630 - 12 926) for BFMS vs. €3500 (range 2509 - 13 393) for LAMS ( P  = 0.10).  LAMS was superior to BFMS in terms of procedure time, with comparable adverse events, success, and costs.

  13. Boomerang proximal tibial osteotomy for the treatment of severe varus gonarthrosis.

    PubMed

    Sangkaew, Chanchit; Piyapittayanun, Peerapong

    2013-06-01

    The purpose of the study was to review the results of modified infratubercle displacement osteotomy in patients with severe varus gonarthrosis and to determine the factors influencing outcomes. A total of 177 knees in 133 patients with severe varus gonarthrosis were treated with infratubercle boomerang-shaped osteotomy, stabilised with dual plates. The mean age of the patients was 63.8 years (range 43-80 years), and the mean follow-up period was 61.4 months (range 24 -139 months). The factors associated with clinical and survival outcomes were analysed including age, gender, body mass index (BMI), preoperative and post-operative femorotibial angle and femorotibial angle at one year after surgery. Using the Knee Society clinical rating system 149 knees or 84.2 % were rated as having good to excellent results and 21 knees or 15.8 % as having fair to poor results. Overall, the mean preoperative knee score of 33.6 points had improved significantly to 80.7 points at the final follow-up (p < 0.001). Using Kaplan-Meier survivorship analysis the five-year survival was 97.1 % with conversion to arthroplasty or second osteotomy as the end point and 89.2 % with a knee score of under 70 points as the end point. The anatomical femorotibial angle at one year after osteotomy had the most significant positive effect on the clinical (p < 0.001) and survival outcomes for all end points (p = 0.002 for conversion to arthroplasty or second osteotomy and p < 0.001 for knee score less than 70 points). The boomerang osteotomy can create adequate valgus alignment in severe varus gonarthrosis. The one-year post-operative knee alignment of 11° valgus provided the most satisfactory results and that between six and 15° valgus the longest survival time.

  14. Determining the Dimensions of the Heliosphere from the Time-Correlation of IBEX ENA Observations with Variations in the Solar Wind Dynamic Pressure

    NASA Astrophysics Data System (ADS)

    Reisenfeld, D. B.; Bzowski, M.; Funsten, H. O.; Janzen, P. H.; Kubiak, M. A.; McComas, D. J.; Schwadron, N.; Sokol, J. M.

    2017-12-01

    The IBEX mission has shown that variations in the ENA flux from the outer heliosphere are associated with the solar cycle. In particular, there is a good correlation between the dynamic pressure of the outbound solar wind and variations in the observed IBEX ENA flux (McComas et al, 2017; Reisenfeld et al., 2016). There is, of course, a time difference between observations of the outbound SW and the heliospheric ENAs with which they correlate, ranging from approximately two to four years, depending on ENA energy and look direction. In this study, we use this time difference as a means of "sounding" the heliosheath, that is, finding the average distance to the ENA source region in a particular direction. We use data from the first seven years of the IBEX mission. As each point in the sky is sampled once every six months, this gives us a time series of 14 points per look direction on which to time correlate. Fluxes are transformed from the spacecraft frame into a heliospheric inertial frame to remove the effects of spacecraft/Earth motion. Fluxes are also corrected for ENA extinction due to charge exchange. To improve statistics, we divide the sky into "macropixels" spanning 30 degrees in longitude and varying ranges of latitude to maintain comparable counting statistics per pixel. In calculating the response time, we account for the varying speed of the outbound solar wind by using a time and latitude dependent set of solar wind speeds derived from interplanetary scintillation data (Sokol et al. 2015). Consistent with heliospheric models, we determine the shortest distance to the heliopause is in the nose direction, with a flaring toward the flanks and poles.

  15. Effect of target color and scanning geometry on terrestrial LiDAR point-cloud noise and plane fitting

    NASA Astrophysics Data System (ADS)

    Bolkas, Dimitrios; Martinez, Aaron

    2018-01-01

    Point-cloud coordinate information derived from terrestrial Light Detection And Ranging (LiDAR) is important for several applications in surveying and civil engineering. Plane fitting and segmentation of target-surfaces is an important step in several applications such as in the monitoring of structures. Reliable parametric modeling and segmentation relies on the underlying quality of the point-cloud. Therefore, understanding how point-cloud errors affect fitting of planes and segmentation is important. Point-cloud intensity, which accompanies the point-cloud data, often goes hand-in-hand with point-cloud noise. This study uses industrial particle boards painted with eight different colors (black, white, grey, red, green, blue, brown, and yellow) and two different sheens (flat and semi-gloss) to explore how noise and plane residuals vary with scanning geometry (i.e., distance and incidence angle) and target-color. Results show that darker colors, such as black and brown, can produce point clouds that are several times noisier than bright targets, such as white. In addition, semi-gloss targets manage to reduce noise in dark targets by about 2-3 times. The study of plane residuals with scanning geometry reveals that, in many of the cases tested, residuals decrease with increasing incidence angles, which can assist in understanding the distribution of plane residuals in a dataset. Finally, a scheme is developed to derive survey guidelines based on the data collected in this experiment. Three examples demonstrate that users should consider instrument specification, required precision of plane residuals, required point-spacing, target-color, and target-sheen, when selecting scanning locations. Outcomes of this study can aid users to select appropriate instrumentation and improve planning of terrestrial LiDAR data-acquisition.

  16. Gambling scores for earthquake predictions and forecasts

    NASA Astrophysics Data System (ADS)

    Zhuang, Jiancang

    2010-04-01

    This paper presents a new method, namely the gambling score, for scoring the performance earthquake forecasts or predictions. Unlike most other scoring procedures that require a regular scheme of forecast and treat each earthquake equally, regardless their magnitude, this new scoring method compensates the risk that the forecaster has taken. Starting with a certain number of reputation points, once a forecaster makes a prediction or forecast, he is assumed to have betted some points of his reputation. The reference model, which plays the role of the house, determines how many reputation points the forecaster can gain if he succeeds, according to a fair rule, and also takes away the reputation points betted by the forecaster if he loses. This method is also extended to the continuous case of point process models, where the reputation points betted by the forecaster become a continuous mass on the space-time-magnitude range of interest. We also calculate the upper bound of the gambling score when the true model is a renewal process, the stress release model or the ETAS model and when the reference model is the Poisson model.

  17. The Relationship between Parenting Stress and Behavior Problems of Children with Autistic Spectrum Disorders

    ERIC Educational Resources Information Center

    Osborne, Lisa A.; Reed, Phil

    2009-01-01

    Two 9- to 10-month-Iong studies (N = 137) examined the interaction between parenting stress and behavior problems in children with autistic spectrum disorders (ASDs). Study 1 focused on very young children, and Study 2 employed a wider range of child ages; both studies assessed these factors at 2 points in time. The researchers noted a strong…

  18. Going to Scale: A Nonrandomized Nationwide Trial of the KiVa Antibullying Program for Grades 1-9

    ERIC Educational Resources Information Center

    Karna, Antti; Voeten, Marinus; Little, Todd D.; Poskiparta, Elisa; Alanen, Erkki; Salmivalli, Christina

    2011-01-01

    Objective: The effects of school-based antibullying programs have typically been examined on small samples, with number of schools ranging from 1 to 78 (Farrington & Ttofi, 2009). This study investigated the effectiveness of the KiVa antibullying program in the beginning of its nationwide implementation in Finland. Method: At each time point,…

  19. Mild cognitive impairment: baseline and longitudinal structural MR imaging measures improve predictive prognosis.

    PubMed

    McEvoy, Linda K; Holland, Dominic; Hagler, Donald J; Fennema-Notestine, Christine; Brewer, James B; Dale, Anders M

    2011-06-01

    To assess whether single-time-point and longitudinal volumetric magnetic resonance (MR) imaging measures provide predictive prognostic information in patients with amnestic mild cognitive impairment (MCI). This study was conducted with institutional review board approval and in compliance with HIPAA regulations. Written informed consent was obtained from all participants or the participants' legal guardians. Cross-validated discriminant analyses of MR imaging measures were performed to differentiate 164 Alzheimer disease (AD) cases from 203 healthy control cases. Separate analyses were performed by using data from MR images obtained at one time point or by combining single-time-point measures with 1-year change measures. Resulting discriminant functions were applied to 317 MCI cases to derive individual patient risk scores. Risk of conversion to AD was estimated as a continuous function of risk score percentile. Kaplan-Meier survival curves were computed for risk score quartiles. Odds ratios (ORs) for the conversion to AD were computed between the highest and lowest quartile scores. Individualized risk estimates from baseline MR examinations indicated that the 1-year risk of conversion to AD ranged from 3% to 40% (average group risk, 17%; OR, 7.2 for highest vs lowest score quartiles). Including measures of 1-year change in global and regional volumes significantly improved risk estimates (P = 001), with the risk of conversion to AD in the subsequent year ranging from 3% to 69% (average group risk, 27%; OR, 12.0 for highest vs lowest score quartiles). Relative to the risk of conversion to AD conferred by the clinical diagnosis of MCI alone, MR imaging measures yield substantially more informative patient-specific risk estimates. Such predictive prognostic information will be critical if disease-modifying therapies become available. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101975/-/DC1. RSNA, 2011

  20. Postural Stability in Cigarette Smokers and During Abstinence from Alcohol

    PubMed Central

    Schmidt, Thomas Paul; Pennington, David Louis; Durazzo, Timothy Craig; Meyerhoff, Dieter Johannes

    2014-01-01

    Background Static postural instability is common in alcohol dependent individuals (ALC). Chronic alcohol consumption has deleterious effects on the neural and perceptual systems subserving postural stability. However, little is known about the effects of chronic cigarette smoking on postural stability and its changes during abstinence from alcohol. Methods A modified Fregly ataxia battery was administered to a total of 115 smoking (sALC) and non-smoking ALC (nsALC) and to 74 smoking (sCON) and non-smoking light/non-drinking controls (nsCON). Subgroups of abstinent ALC were assessed at 3 time points (approximately 1 week, 5 weeks, 34 weeks of abstinence from alcohol); a subset of nsCON was re-tested at 40 weeks. We tested if cigarette smoking affects postural stability in CON and in ALC during extended abstinence from alcohol, and we used linear mixed effects modeling to measure change across time points within ALC. Results Chronic smoking was associated with reduced performance on the Sharpened Romberg eyes-closed task in abstinent ALC at all three time points and in CON. The test performance of nsALC increased significantly between 1 and 32 weeks of abstinence, whereas the corresponding increases for sALC between 1 and 35 weeks was non-significant. With long-term abstinence from alcohol, nsALC recovered into the range of nsCON and sALC recovered into the range of sCON. Static postural stability decreased with age and correlated with smoking variables but not with drinking measures. Conclusions Chronic smoking was associated with reduced static postural stability with eyes closed and with lower increases of postural stability during abstinence from alcohol. Smoking cessation in alcohol dependence treatment may facilitate recovery from static postural instability during abstinence. PMID:24721012

  1. Optimal intravenous infusion to decrease the haematocrit level in patient of DHF infection

    NASA Astrophysics Data System (ADS)

    Handayani, D.; Nuraini, N.; Saragih, R.; Wijaya, K. P.; Naiborhu, J.

    2014-02-01

    The optimal control of infusion model for Dengue Hemorrhagic Fever (DHF) infection is formulated here. The infusion model will be presented in form of haematocrit level. The input control aim to normalize the haematocrit level and is expressed as infusion volume on mL/day. The stability near the equilibrium points will be analyzed. Numerical simulation shows the dynamic of each infection compartments which gives a description of within-host dynamic of dengue virus. These results show particularly that infected compartments tend to be vanished in ±15days after the onset of the virus. In fact, without any control added, the haematocrit level will decrease but not up to the normal level. Therefore the effective haematocrit normalization should be done with the treatment control. Control treatment for a fixed time using a control input can bring haematocrit level to normal range 42-47%. The optimal control in this paper is divided into three cases, i.e. fixed end point, constrained input, and tracking haematocrit state. Each case shows different infection condition in human body. However, all cases require that the haematocrit level to be in normal range in fixed final time.

  2. An approximate, maximum terminal velocity descent to a point

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eisler, G.R.; Hull, D.G.

    1987-01-01

    No closed form control solution exists for maximizing the terminal velocity of a hypersonic glider at an arbitrary point. As an alternative, this study uses neighboring extremal theory to provide a sampled data feedback law to guide the vehicle to a constrained ground range and altitude. The guidance algorithm is divided into two parts: 1) computation of a nominal, approximate, maximum terminal velocity trajectory to a constrained final altitude and computation of the resulting unconstrained groundrange, and 2) computation of the neighboring extremal control perturbation at the sample value of flight path angle to compensate for changes in the approximatemore » physical model and enable the vehicle to reach the on-board computed groundrange. The trajectories are characterized by glide and dive flight to the target to minimize the time spent in the denser parts of the atmosphere. The proposed on-line scheme successfully brings the final altitude and range constraints together, as well as compensates for differences in flight model, atmosphere, and aerodynamics at the expense of guidance update computation time. Comparison with an independent, parameter optimization solution for the terminal velocity is excellent. 6 refs., 3 figs.« less

  3. Women With Breast Cancer: Self-Reported Distress in Early Survivorship

    PubMed Central

    Lester, Joanne; Crosthwaite, Kara; Stout, Robin; Jones, Rachel N.; Holloman, Christopher; Shapiro, Charles; Andersen, Barbara L.

    2015-01-01

    Purpose/Objectives To identify and compare levels of distress and sources of problems among patients with breast cancer in early survivorship. Design Descriptive, cross-sectional. Setting A National Cancer Institute–designated comprehensive cancer center. Sample 100 breast cancer survivors were selected to represent four time points in the cancer trajectory. Methods Distress was self-reported using the Distress Thermometer and its 38-item problem list. Analysis of variance and chi-square analyses were performed as appropriate. Main Research Variables Distress scores, problem reports, and time groups. Findings Participants scored in range of the cutoff of more than 4 (range = 4.1–5.1) from treatment through three months post-treatment. At six months post-treatment, distress levels were significantly lower. Significant differences were found between groups on the total problem list score (p = 0.007) and emotional (p = 0.01) and physical subscale scores (p = 0.003). Conclusions Comparison of groups at different points in the cancer trajectory found similar elevated levels from diagnosis through three months. Distress remained elevated in early survivorship but significantly decreased at six months post-treatment. Implications for Nursing Interventions to reduce or prevent distress may improve outcomes in early survivorship. PMID:25542330

  4. Statistical Attitude Determination

    NASA Technical Reports Server (NTRS)

    Markley, F. Landis

    2010-01-01

    All spacecraft require attitude determination at some level of accuracy. This can be a very coarse requirement of tens of degrees, in order to point solar arrays at the sun, or a very fine requirement in the milliarcsecond range, as required by Hubble Space Telescope. A toolbox of attitude determination methods, applicable across this wide range, has been developed over the years. There have been many advances in the thirty years since the publication of Reference, but the fundamentals remain the same. One significant change is that onboard attitude determination has largely superseded ground-based attitude determination, due to the greatly increased power of onboard computers. The availability of relatively inexpensive radiation-hardened microprocessors has led to the development of "smart" sensors, with autonomous star trackers being the first spacecraft application. Another new development is attitude determination using interferometry of radio signals from the Global Positioning System (GPS) constellation. This article reviews both the classic material and these newer developments at approximately the level of, with emphasis on. methods suitable for use onboard a spacecraft. We discuss both "single frame" methods that are based on measurements taken at a single point in time, and sequential methods that use information about spacecraft dynamics to combine the information from a time series of measurements.

  5. Ion-pair cloud-point extraction: a new method for the determination of water-soluble vitamins in plasma and urine.

    PubMed

    Heydari, Rouhollah; Elyasi, Najmeh S

    2014-10-01

    A novel, simple, and effective ion-pair cloud-point extraction coupled with a gradient high-performance liquid chromatography method was developed for determination of thiamine (vitamin B1 ), niacinamide (vitamin B3 ), pyridoxine (vitamin B6 ), and riboflavin (vitamin B2 ) in plasma and urine samples. The extraction and separation of vitamins were achieved based on an ion-pair formation approach between these ionizable analytes and 1-heptanesulfonic acid sodium salt as an ion-pairing agent. Influential variables on the ion-pair cloud-point extraction efficiency, such as the ion-pairing agent concentration, ionic strength, pH, volume of Triton X-100, extraction temperature, and incubation time have been fully evaluated and optimized. Water-soluble vitamins were successfully extracted by 1-heptanesulfonic acid sodium salt (0.2% w/v) as ion-pairing agent with Triton X-100 (4% w/v) as surfactant phase at 50°C for 10 min. The calibration curves showed good linearity (r(2) > 0.9916) and precision in the concentration ranges of 1-50 μg/mL for thiamine and niacinamide, 5-100 μg/mL for pyridoxine, and 0.5-20 μg/mL for riboflavin. The recoveries were in the range of 78.0-88.0% with relative standard deviations ranging from 6.2 to 8.2%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Laser Dew-Point Hygrometer

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki; Toyooka, Satoru

    1995-01-01

    A rough-surface-type automatic dew-point hygrometer was developed using a laser diode and an optical fiber cable. A gold plate with 0.8 µ m average surface roughness was used as a surface for deposition of dew to facilitate dew deposition and prevent supersaturation of water vapor at the dew point. It was shown experimentally that the quantity of dew deposited can be controlled to be constant at any predetermined level, and is independent of the dew point to be measured. The dew points were measured in the range from -15° C to 54° C in which the temperature ranged from 0° C to 60° C. The measurement error of the dew point was ±0.5° C which was equal to below ±2% in relative humidity in the above dew-point range.

  7. Prediction of Febrile Neutropenia after Chemotherapy Based on Pretreatment Risk Factors among Cancer Patients

    PubMed Central

    Aagaard, Theis; Roen, Ashley; Daugaard, Gedske; Brown, Peter; Sengeløv, Henrik; Mocroft, Amanda; Lundgren, Jens; Helleberg, Marie

    2017-01-01

    Abstract Background Febrile neutropenia (FN) is a common complication to chemotherapy associated with a high burden of morbidity and mortality. Reliable prediction of individual risk based on pretreatment risk factors allows for stratification of preventive interventions. We aimed to develop such a risk stratification model to predict FN in the 30 days after initiation of chemotherapy. Methods We included consecutive treatment-naïve patients with solid cancers and diffuse large B-cell lymphomas at Copenhagen University Hospital, 2010–2015. Data were obtained from the PERSIMUNE repository of electronic health records. FN was defined as neutrophils ≤0.5 × 10E9/L ​at the time of either a blood culture sample or death. Time from initiation of chemotherapy to FN was analyzed using Fine-Gray models with death as a competing event. Risk factors investigated were: age, sex, body surface area, haemoglobin, albumin, neutrophil-to-lymphocyte ratio, Charlson Comorbidity Index (CCI) and chemotherapy drugs. Parameter estimates were scaled and summed to create the risk score. The scores were grouped into four: low, intermediate, high and very high risk. Results Among 8,585 patients, 467 experienced FN, incidence rate/30 person-days 0.05 (95% CI, 0.05–0.06). Age (1 point if > 65 years), albumin (1 point if < 39 g/L), CCI (1 point if > 2) and chemotherapy (range -5 to 6 points/drug) predicted FN. Median score at inclusion was 2 points (range –5 to 9). The cumulative incidence and the incidence rates and hazard ratios of FN are shown in Figure 1 and Table 1, respectively. Conclusion We developed a risk score to predict FN the first month after initiation of chemotherapy. The score is easy to use and provides good differentiation of risk groups; the score needs independent validation before routine use. Disclosures All authors: No reported disclosures.

  8. Mapping stream habitats with a global positioning system: Accuracy, precision, and comparison with traditional methods

    USGS Publications Warehouse

    Dauwalter, D.C.; Fisher, W.L.; Belt, K.C.

    2006-01-01

    We tested the precision and accuracy of the Trimble GeoXT??? global positioning system (GPS) handheld receiver on point and area features and compared estimates of stream habitat dimensions (e.g., lengths and areas of riffles and pools) that were made in three different Oklahoma streams using the GPS receiver and a tape measure. The precision of differentially corrected GPS (DGPS) points was not affected by the number of GPS position fixes (i.e., geographic location estimates) averaged per DGPS point. Horizontal error of points ranged from 0.03 to 2.77 m and did not differ with the number of position fixes per point. The error of area measurements ranged from 0.1% to 110.1% but decreased as the area increased. Again, error was independent of the number of position fixes averaged per polygon corner. The estimates of habitat lengths, widths, and areas did not differ when measured using two methods of data collection (GPS and a tape measure), nor did the differences among methods change at three stream sites with contrasting morphologies. Measuring features with a GPS receiver was up to 3.3 times faster on average than using a tape measure, although signal interference from high streambanks or overhanging vegetation occasionally limited satellite signal availability and prolonged measurements with a GPS receiver. There were also no differences in precision of habitat dimensions when mapped using a continuous versus a position fix average GPS data collection method. Despite there being some disadvantages to using the GPS in stream habitat studies, measuring stream habitats with a GPS resulted in spatially referenced data that allowed the assessment of relative habitat position and changes in habitats over time, and was often faster than using a tape measure. For most spatial scales of interest, the precision and accuracy of DGPS data are adequate and have logistical advantages when compared to traditional methods of measurement. ?? 2006 Springer Science+Business Media, Inc.

  9. Large-Scale Coronal Heating from the Solar Magnetic Network

    NASA Technical Reports Server (NTRS)

    Falconer, David A.; Moore, Ronald L.; Porter, Jason G.; Hathaway, David H.

    1999-01-01

    In Fe 12 images from SOHO/EIT, the quiet solar corona shows structure on scales ranging from sub-supergranular (i.e., bright points and coronal network) to multi- supergranular. In Falconer et al 1998 (Ap.J., 501, 386) we suppressed the large-scale background and found that the network-scale features are predominantly rooted in the magnetic network lanes at the boundaries of the supergranules. The emission of the coronal network and bright points contribute only about 5% of the entire quiet solar coronal Fe MI emission. Here we investigate the large-scale corona, the supergranular and larger-scale structure that we had previously treated as a background, and that emits 95% of the total Fe XII emission. We compare the dim and bright halves of the large- scale corona and find that the bright half is 1.5 times brighter than the dim half, has an order of magnitude greater area of bright point coverage, has three times brighter coronal network, and has about 1.5 times more magnetic flux than the dim half These results suggest that the brightness of the large-scale corona is more closely related to the large- scale total magnetic flux than to bright point activity. We conclude that in the quiet sun: (1) Magnetic flux is modulated (concentrated/diluted) on size scales larger than supergranules. (2) The large-scale enhanced magnetic flux gives an enhanced, more active, magnetic network and an increased incidence of network bright point formation. (3) The heating of the large-scale corona is dominated by more widespread, but weaker, network activity than that which heats the bright points. This work was funded by the Solar Physics Branch of NASA's office of Space Science through the SR&T Program and the SEC Guest Investigator Program.

  10. Time-resolved contrast-enhanced MR angiography of the thorax in adults with congenital heart disease.

    PubMed

    Mohrs, Oliver K; Petersen, Steffen E; Voigtlaender, Thomas; Peters, Jutta; Nowak, Bernd; Heinemann, Markus K; Kauczor, Hans-Ulrich

    2006-10-01

    The aim of this study was to evaluate the diagnostic value of time-resolved contrast-enhanced MR angiography in adults with congenital heart disease. Twenty patients with congenital heart disease (mean age, 38 +/- 14 years; range, 16-73 years) underwent contrast-enhanced turbo fast low-angle shot MR angiography. Thirty consecutive coronal 3D slabs with a frame rate of 1-second duration were acquired. The mask defined as the first data set was subtracted from subsequent images. Image quality was evaluated using a 5-point scale (from 1, not assessable, to 5, excellent image quality). Twelve diagnostic parameters yielded 1 point each in case of correct diagnosis (binary analysis into normal or abnormal) and were summarized into three categories: anatomy of the main thoracic vessels (maximum, 5 points), sequential cardiac anatomy (maximum, 5 points), and shunt detection (maximum, 2 points). The results were compared with a combined clinical reference comprising medical or surgical reports and other imaging studies. Diagnostic accuracies were calculated for each of the parameters as well as for the three categories. The mean image quality was 3.7 +/- 1.0. Using a binary approach, 220 (92%) of the 240 single diagnostic parameters could be analyzed. The percentage of maximum diagnostic points, the sensitivity, the specificity, and the positive and the negative predictive values were all 100% for the anatomy of the main thoracic vessels; 97%, 87%, 100%, 100%, and 96% for sequential cardiac anatomy; and 93%, 93%, 92%, 88%, and 96% for shunt detection. Time-resolved contrast-enhanced MR angiography provides, in one breath-hold, anatomic and qualitative functional information in adult patients with congenital heart disease. The high diagnostic accuracy allows the investigator to tailor subsequent specific MR sequences within the same session.

  11. An Experiment to Detect Lunar Horizon Glow with the Lunar Orbit Laser Altimeter Laser Ranging Telescope

    NASA Astrophysics Data System (ADS)

    Smith, David E.; Zuber, Maria T.; Barker, Michael; Mazarico, Erwan; Neumann, Gregory A.; McClanahan, Timothy P.; Sun, Xiaoli

    2016-04-01

    Lunar horizon glow (LHG) was an observation by the Apollo astronauts of a brightening of the horizon around the time of sunrise. The effect has yet to be fully explained or confirmed by instruments on lunar orbiting spacecraft despite several attempts. The Lunar Reconnaissance Orbiter (LRO) spacecraft carries the laser altimeter (LOLA) instrument which has a 2.5 cm aperture telescope for Earth-based laser ranging (LR) mounted and bore-sighted with the high gain antenna (HGA). The LR telescope is connected to LOLA by a fiber-glass cable to one of its 5 detectors. For the LGH experiments the LR telescope is pointed toward the horizon shortly before lunar sunrise with the intent of observing any forward scattering of sunlight due to the presence of dust or particles in the field of view. Initially, the LR telescope is pointed at the dark lunar surface, which provides a measure of the dark count, and moves toward the lunar limb so as to measure the brightness of the sky just above the lunar limb immediately prior to lunar sunrise. At no time does the sun shine directly into the LR telescope, although the LR telescope is pointed as close to the sun as the 1.75-degree field of view permits. Experiments show that the LHG signal seen by the astronauts can be detected with a four-second integration of the noise counts.

  12. Brief report: a preliminary study of fetal head circumference growth in autism spectrum disorder.

    PubMed

    Whitehouse, Andrew J O; Hickey, Martha; Stanley, Fiona J; Newnham, John P; Pennell, Craig E

    2011-01-01

    Fetal head circumference (HC) growth was examined prospectively in children with autism spectrum disorder (ASD). ASD participants (N = 14) were each matched with four control participants (N = 56) on a range of parameters known to influence fetal growth. HC was measured using ultrasonography at approximately 18 weeks gestation and again at birth using a paper tape-measure. Overall body size was indexed by fetal femur-length and birth length. There was no between-groups difference in head circumference at either time-point. While a small number of children with ASD had disproportionately large head circumference relative to body size at both time-points, the between-groups difference did not reach statistical significance in this small sample. These preliminary findings suggest that further investigation of fetal growth in ASD is warranted.

  13. Treatment of Medial Malleolus or Pure Deltoid Ligament Injury in Patients with Supination-External Rotation Type IV Ankle Fractures.

    PubMed

    Wang, Xu; Zhang, Chao; Yin, Jian-Wen; Wang, Chen; Huang, Jia-Zhang; Ma, Xin; Wang, Cheng-Wei; Wang, Xue

    2017-02-01

    To investigate the effect of internal fixation on postoperative ankle function in patients with supination-external rotation type IV ankle fractures, including medial malleolus fractures and deltoid ligament injury. Between January 2012 and June 2014, patients with medial structure injuries were enrolled in this study and assigned to the medial malleolus fracture group or the deltoid ligament group. The surgical procedures for the two groups were documented. The follow-up endpoint was the time point when the steel plate or screw was removed from the lateral ankle. The Olerud-Molander ankle scoring system was used to assess ankle function. A total of 84 patients with supination-external rotation type IV ankle fractures had complete medical records and were included in this study. The average age of the patients was 44.16 years (range, 15-75). The patient sample included 39 males and 45 females. Overall, 49 patients (19 males and 30 females) suffered a medial malleolus fracture. The average age of these patients was 40.20 years (range, 15-75). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 81.6% (40 patients) of these patients. Overall, 35 patients (20 males and 15 females) experienced a deltoid ligament injury. The average age of these patients was 44.21 years (range, 17-73). Patients with a posterior malleolar fracture fragment >25% of the articular surface accounted for 11.5% (four patients) of these patients. Open reduction was performed in patients with medial malleolus fractures, and two 4.0-mm cannulated screws were used to fixate the posterior malleolus and the medial malleolus. The suture-anchor technique was used to repair the ligaments in patients with deltoid ligament injuries. The follow-up endpoint was the time point when the steel plate and screws were removed from the lateral ankle in patients. The average follow-up period was 13.4 months (range, 11-17). The Olerud-Molander ankle scoring system was used to assess postoperative ankle function. The average score for the patients in the medial malleolus fracture group was 90.3 points (range, 85-95). The average score for the patients in the deltoid ligament injury group was 87.7 points (range, 80-95). No significant differences were found in the scores between the two groups. Medial malleolus fracture and deltoid ligament injury are two different presentations of supination-external rotation type IV ankle fractures. Anatomic reduction of the articular surface concurrent with restoration of ankle stability can achieve favorable results for these two injuries. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  14. New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from -70 °C to +60 °C

    NASA Astrophysics Data System (ADS)

    Zvizdic, Davor; Heinonen, Martti; Sestan, Danijel

    2012-09-01

    To extend the dew-point range and to improve the uncertainties of the humidity scale realization at HMI/FSB-LPM, new primary low- and high-range dew-point generators were developed and implemented in cooperation with MIKES, in 2009 through EUROMET Project No. 912. The low-range saturator is designed for primary realization of the dew-point temperature scale from -70 °C to + 5 °C, while the high-range saturator covers the range from 1 °C to 60 °C. The system is designed as a single-pressure, single-pass dew-point generator. MIKES designed and constructed both the saturators to be implemented in dew-point calibration systems at LPM. The LPM took care of purchasing and adapting liquid baths, of implementing the temperature and pressure measurement equipment appropriate for use in the systems, and development of gas preparation and flow control systems as well as of the computer-based automated data acquisition. The principle and the design of the generator are described in detail and schematically depicted. The tests were performed at MIKES to investigate how close both the saturators are to an ideal saturator. Results of the tests show that both the saturators are efficient enough for a primary realization of the dew-point temperature scale from -70 °C to + 60 °C, in the specified flow-rate ranges. The estimated standard uncertainties due to the non-ideal saturation efficiency are between 0.02 °C and 0.05 °C.

  15. Raster Vs. Point Cloud LiDAR Data Classification

    NASA Astrophysics Data System (ADS)

    El-Ashmawy, N.; Shaker, A.

    2014-09-01

    Airborne Laser Scanning systems with light detection and ranging (LiDAR) technology is one of the fast and accurate 3D point data acquisition techniques. Generating accurate digital terrain and/or surface models (DTM/DSM) is the main application of collecting LiDAR range data. Recently, LiDAR range and intensity data have been used for land cover classification applications. Data range and Intensity, (strength of the backscattered signals measured by the LiDAR systems), are affected by the flying height, the ground elevation, scanning angle and the physical characteristics of the objects surface. These effects may lead to uneven distribution of point cloud or some gaps that may affect the classification process. Researchers have investigated the conversion of LiDAR range point data to raster image for terrain modelling. Interpolation techniques have been used to achieve the best representation of surfaces, and to fill the gaps between the LiDAR footprints. Interpolation methods are also investigated to generate LiDAR range and intensity image data for land cover classification applications. In this paper, different approach has been followed to classifying the LiDAR data (range and intensity) for land cover mapping. The methodology relies on the classification of the point cloud data based on their range and intensity and then converted the classified points into raster image. The gaps in the data are filled based on the classes of the nearest neighbour. Land cover maps are produced using two approaches using: (a) the conventional raster image data based on point interpolation; and (b) the proposed point data classification. A study area covering an urban district in Burnaby, British Colombia, Canada, is selected to compare the results of the two approaches. Five different land cover classes can be distinguished in that area: buildings, roads and parking areas, trees, low vegetation (grass), and bare soil. The results show that an improvement of around 10 % in the classification results can be achieved by using the proposed approach.

  16. The temperature dependence of the hydroxyl deuterium quadrupole coupling parameter and the rotational correlation time of the OD internuclear vector in neat ethanol-d

    NASA Astrophysics Data System (ADS)

    Ferris, Thomas D.; Farrar, Thomas C.

    The temperature dependence of the hydroxyl proton chemical shift and deuterium quadrupolar relaxation time of neat ethanol were measured over the temperature range 190-350 K. The proton isotropic chemical shift varies from 6.2 ppm at 190 K to 4.7 ppm at 350 K. The deuterium NMR relaxation time in ethanol- d 1 varies from 6.2 ms to 309 ms over the same range. Ab initio calculations performed on various ethanol clusters ranging in size from monomer to hexamer show a linear correlation ( R 2 = 0.99) between ≤D, the deuterium quadrupole coupling parameter, and δH, the isotropic proton chemical shift in ppm relative to TMS: ≤D(kHz) = 297.60 - 15.28 δH. The temperature dependence of ≤D ranges from 199.5 kHz at 190 K to 221.4 kHz at 350 K. Using the values for ≤D and the relaxation time data, the temperature dependence of the OD rotational correlation time was found to vary from 282 ps at 190 K to 4.5 ps near the boiling point (350 K). Using these correlation times and bulk viscosity data, the Gierer-Wirtz model predicts a supramolecular cluster volume of about 317 A 3 , the approximate volume of a cyclic pentamer cluter of ethanol molecules. The cluster volume was nearly constant from 340 K to about 290 K.

  17. Demographic compensation and tipping points in climate-induced range shifts.

    PubMed

    Doak, Daniel F; Morris, William F

    2010-10-21

    To persist, species are expected to shift their geographical ranges polewards or to higher elevations as the Earth's climate warms. However, although many species' ranges have shifted in historical times, many others have not, or have shifted only at the high-latitude or high-elevation limits, leading to range expansions rather than contractions. Given these idiosyncratic responses to climate warming, and their varied implications for species' vulnerability to climate change, a critical task is to understand why some species have not shifted their ranges, particularly at the equatorial or low-elevation limits, and whether such resilience will last as warming continues. Here we show that compensatory changes in demographic rates are buffering southern populations of two North American tundra plants against the negative effects of a warming climate, slowing their northward range shifts, but that this buffering is unlikely to continue indefinitely. Southern populations of both species showed lower survival and recruitment but higher growth of individual plants, possibly owing to longer, warmer growing seasons. Because of these and other compensatory changes, the population growth rates of southern populations are not at present lower than those of northern ones. However, continued warming may yet prove detrimental, as most demographic rates that improved in moderately warmer years declined in the warmest years, with the potential to drive future population declines. Our results emphasize the need for long-term, range-wide measurement of all population processes to detect demographic compensation and to identify nonlinear responses that may lead to sudden range shifts as climatic tipping points are exceeded.

  18. Symmetry recovery for coupled photonic modes with transversal PT symmetry.

    PubMed

    Rivolta, Nicolas X A; Maes, Bjorn

    2015-08-15

    Typical parity-time (PT) symmetric structures switch from the unbroken to the broken phase when gain increases through an exceptional point. In contrast, we report on systems with the unusual, reverse behavior, where the symmetric phase is recovered after a broken phase. We study this phenomenon analytically and numerically in the simplest possible system, consisting of four coupled modes, and we present potential dielectric and plasmonic implementations. The complex mode merging scheme, with two distinct unbroken PT phases encompassing a broken one, appears for a specific proportion range of the coupling constants. This regime with "inverse" exceptional points is interesting for the design of novel PT devices.

  19. Sleep Restriction Therapy for Insomnia is Associated with Reduced Objective Total Sleep Time, Increased Daytime Somnolence, and Objectively Impaired Vigilance: Implications for the Clinical Management of Insomnia Disorder

    PubMed Central

    Kyle, Simon D.; Miller, Christopher B.; Rogers, Zoe; Siriwardena, A. Niroshan; MacMahon, Kenneth M.; Espie, Colin A.

    2014-01-01

    Study Objectives: To investigate whether sleep restriction therapy (SRT) is associated with reduced objective total sleep time (TST), increased daytime somnolence, and impaired vigilance. Design: Within-subject, noncontrolled treatment investigation. Setting: Sleep research laboratory. Participants: Sixteen patients [10 female, mean age = 47.1 (10.8) y] with well-defined psychophysiological insomnia (PI), reporting TST ≤ 6 h. Interventions: Patients were treated with single-component SRT over a 4-w protocol, sleeping in the laboratory for 2 nights prior to treatment initiation and for 3 nights (SRT night 1, 8, 22) during the acute interventional phase. The psychomotor vigilance task (PVT) was completed at seven defined time points [day 0 (baseline), day 1,7,8,21,22 (acute treatment) and day 84 (3 mo)]. The Epworth Sleepiness Scale (ESS) was completed at baseline, w 1-4, and 3 mo. Measurement and results: Subjective sleep outcomes and global insomnia severity significantly improved before and after SRT. There was, however, a robust decrease in PSG-defined TST during acute implementation of SRT, by an average of 91 min on night 1, 78 min on night 8, and 69 min on night 22, relative to baseline (P < 0.001; effect size range = 1.60-1.80). During SRT, PVT lapses were significantly increased from baseline (at three of five assessment points, all P < 0.05; effect size range = 0.69-0.78), returning to baseline levels by 3 mo (P = 0.43). A similar pattern was observed for RT, with RTs slowing during acute treatment (at four of five assessment points, all P < 0.05; effect size range = 0.57-0.89) and returning to pretreatment levels at 3 mo (P = 0.78). ESS scores were increased at w 1, 2, and 3 (relative to baseline; all P < 0.05); by 3 mo, sleepiness had returned to baseline (normative) levels (P = 0.65). Conclusion: For the first time we show that acute sleep restriction therapy is associated with reduced objective total sleep time, increased daytime sleepiness, and objective performance impairment. Our data have important implications for implementation guidelines around the safe and effective delivery of cognitive behavioral therapy for insomnia. Citation: Kyle SD; Miller CB; Rogers Z; Siriwardena AN; MacMahon KM; Espie CA. Sleep restriction therapy for insomnia is associated with reduced objective total sleep time, increased daytime somnolence, and objectively impaired vigilance: implications for the clinical management of insomnia disorder. SLEEP 2014;37(2):229-237. PMID:24497651

  20. Remaining dischargeable time prediction for lithium-ion batteries using unscented Kalman filter

    NASA Astrophysics Data System (ADS)

    Dong, Guangzhong; Wei, Jingwen; Chen, Zonghai; Sun, Han; Yu, Xiaowei

    2017-10-01

    To overcome the range anxiety, one of the important strategies is to accurately predict the range or dischargeable time of the battery system. To accurately predict the remaining dischargeable time (RDT) of a battery, a RDT prediction framework based on accurate battery modeling and state estimation is presented in this paper. Firstly, a simplified linearized equivalent-circuit-model is developed to simulate the dynamic characteristics of a battery. Then, an online recursive least-square-algorithm method and unscented-Kalman-filter are employed to estimate the system matrices and SOC at every prediction point. Besides, a discrete wavelet transform technique is employed to capture the statistical information of past dynamics of input currents, which are utilized to predict the future battery currents. Finally, the RDT can be predicted based on the battery model, SOC estimation results and predicted future battery currents. The performance of the proposed methodology has been verified by a lithium-ion battery cell. Experimental results indicate that the proposed method can provide an accurate SOC and parameter estimation and the predicted RDT can solve the range anxiety issues.

  1. Super Clausius-Clapeyron scaling of extreme hourly precipitation and its relation to large-scale atmospheric conditions

    NASA Astrophysics Data System (ADS)

    Lenderink, Geert; Barbero, Renaud; Loriaux, Jessica; Fowler, Hayley

    2017-04-01

    Present-day precipitation-temperature scaling relations indicate that hourly precipitation extremes may have a response to warming exceeding the Clausius-Clapeyron (CC) relation; for The Netherlands the dependency on surface dew point temperature follows two times the CC relation corresponding to 14 % per degree. Our hypothesis - as supported by a simple physical argument presented here - is that this 2CC behaviour arises from the physics of convective clouds. So, we think that this response is due to local feedbacks related to the convective activity, while other large scale atmospheric forcing conditions remain similar except for the higher temperature (approximately uniform warming with height) and absolute humidity (corresponding to the assumption of unchanged relative humidity). To test this hypothesis, we analysed the large-scale atmospheric conditions accompanying summertime afternoon precipitation events using surface observations combined with a regional re-analysis for the data in The Netherlands. Events are precipitation measurements clustered in time and space derived from approximately 30 automatic weather stations. The hourly peak intensities of these events again reveal a 2CC scaling with the surface dew point temperature. The temperature excess of moist updrafts initialized at the surface and the maximum cloud depth are clear functions of surface dew point temperature, confirming the key role of surface humidity on convective activity. Almost no differences in relative humidity and the dry temperature lapse rate were found across the dew point temperature range, supporting our theory that 2CC scaling is mainly due to the response of convection to increases in near surface humidity, while other atmospheric conditions remain similar. Additionally, hourly precipitation extremes are on average accompanied by substantial large-scale upward motions and therefore large-scale moisture convergence, which appears to accelerate with surface dew point. This increase in large-scale moisture convergence appears to be consequence of latent heat release due to the convective activity as estimated from the quasi-geostrophic omega equation. Consequently, most hourly extremes occur in precipitation events with considerable spatial extent. Importantly, this event size appears to increase rapidly at the highest dew point temperature range, suggesting potentially strong impacts of climatic warming.

  2. The kinetics of white blood cell and the predictive factors of leukocytosis under oral or intravenous arsenic as the first-line treatment for acute promyelocytic leukemia.

    PubMed

    Wang, Fang; Jia, Jin-Song; Wang, Jing; Zhao, Ting; Jiang, Qian; Jiang, Hao; Zhu, Hong-Hu

    2017-10-01

    We aimed to compare the kinetics of white blood cell (WBC) and explore predictive factors of leukocytosis in non-high-risk acute promyelocytic leukemia (APL), with oral arsenic plus all-trans retinoic acid (ATRA) or intravenous arsenic trioxide (ATO) plus ATRA as a first-line treatment. The absolute count, doubling time and peak time of WBC were analyzed in 64 newly diagnosed non-high-risk APL patients who were treated with different induction regimens containing either oral Realgar-indigo naturalis formula (RIF) (n=35) or ATO (n=29). The end points were the dynamic changes of the WBC counts during induction. The time points started at day 1 and were selected over 3-day intervals for 28days. Among the 64 included patients, the median initial and peak WBC counts were 1.78×10 9 /L (range 0.31-9.89) and 12.16×10 9 /L (range 1.56-80.01), respectively. The incidence of differentiation syndrome was 9.38%. The dynamic changes in leukocytosis showed a single peak wave in all the patients, and the median time to peak was 10 (range 2-26) days. A higher WBC count was observed in the RIF group than in the ATO group after 10days of treatment (9.22×10 9 /L vs. 4.10×10 9 /L, p=0.015). Patients with the peak WBC count >10×10 9 /L had a shorter WBC doubling time compared to patients with a lower peak WBC (RIF group 4days vs. 7days, p=0.001; ATO group 4.5days vs. 23days, p=0.002). Univariate and multivariable analyses showed that the doubling time of WBC is an independent factor for the peak WBC count. Different kinetics of WBC proliferation were observed during induction with oral arsenic plus ATRA and ATO plus ATRA. The doubling time of WBC is an important independent factor for predicting the peak WBC count. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Comparison of Interferometric Time-Series Analysis Techniques with Implications for Future Mission Design

    NASA Astrophysics Data System (ADS)

    Werner, C. L.; Wegmuller, U.; Strozzi, T.; Wiesmann, A.

    2006-12-01

    Principle contributors to the noise in differential SAR interferograms are temporal phase stability of the surface, geometry relating to baseline and surface slope, and propagation path delay variations due to tropospheric water vapor and the ionosphere. Time series analysis of multiple interferograms generated from a stack of SAR SLC images seeks to determine the deformation history of the surface while reducing errors. Only those scatterers within a resolution element that are stable and coherent for each interferometric pair contribute to the desired deformation signal. Interferograms with baselines exceeding 1/3 the critical baseline have substantial geometrical decorrelation for distributed targets. Short baseline pairs with multiple reference scenes can be combined using least-squares estimation to obtain a global deformation solution. Alternately point-like persistent scatterers can be identified in scenes that do not exhibit geometrical decorrelation associated with large baselines. In this approach interferograms are formed from a stack of SAR complex images using a single reference scene. Stable distributed scatter pixels are excluded however due to the presence of large baselines. We apply both point- based and short-baseline methodologies and compare results for a stack of fine-beam Radarsat data acquired in 2002-2004 over a rapidly subsiding oil field near Lost Hills, CA. We also investigate the density of point-like scatters with respect to image resolution. The primary difficulty encountered when applying time series methods is phase unwrapping errors due to spatial and temporal gaps. Phase unwrapping requires sufficient spatial and temporal sampling. Increasing the SAR range bandwidth increases the range resolution as well as increasing the critical interferometric baseline that defines the required satellite orbital tube diameter. Sufficient spatial sampling also permits unwrapping because of the reduced phase/pixel gradient. Short time intervals further reduce the differential phase due to deformation when the deformation is continuous. Lower frequency systems (L- vs. C-Band) substantially improve the ability to unwrap the phase correctly by directly reducing both interferometric phase amplitude and temporal decorrelation.

  4. Minimal instructions improve the performance of laypersons in the use of semiautomatic and automatic external defibrillators

    PubMed Central

    Beckers, Stefan; Fries, Michael; Bickenbach, Johannes; Derwall, Matthias; Kuhlen, Ralf; Rossaint, Rolf

    2005-01-01

    Introduction There is evidence that use of automated external defibrillators (AEDs) by laypersons improves rates of survival from cardiac arrest, but there is no consensus on the optimal content and duration of training for this purpose. In this study we examined the use of semiautomatic or automatic AEDs by laypersons who had received no training (intuitive use) and the effects of minimal general theoretical instructions on their performance. Methods In a mock cardiac arrest scenario, 236 first year medical students who had not previously attended any preclinical courses were evaluated in their first study week, before and after receiving prespecified instructions (15 min) once. The primary end-point was the time to first shock for each time point; secondary end-points were correct electrode pad positioning, safety of the procedure and the subjective feelings of the students. Results The mean time to shock for both AED types was 81.2 ± 19.2 s (range 45–178 s). Correct pad placement was observed in 85.6% and adequate safety in 94.1%. The time to shock after instruction decreased significantly to 56.8 ± 9.9 s (range 35–95 s; P ≤ 0.01), with correct electrode placement in 92.8% and adequate safety in 97%. The students were significantly quicker at both evaluations using the semiautomatic device than with the automatic AED (first evaluation: 77.5 ± 20.5 s versus 85.2 ± 17 s, P ≤ 0.01; second evaluation: 55 ± 10.3 s versus 59.6 ± 9.6 s, P ≤ 0.01). Conclusion Untrained laypersons can use semiautomatic and automatic AEDs sufficiently quickly and without instruction. After one use and minimal instructions, improvements in practical performance were significant. All tested laypersons were able to deliver the first shock in under 1 min. PMID:15774042

  5. Point -of -care testing (POCT) in molecular diagnostics: Performance evaluation of GeneXpert HCV RNA test in diagnosing and monitoring of HCV infection.

    PubMed

    Gupta, Ekta; Agarwala, Pragya; Kumar, Guresh; Maiwall, Rakhi; Sarin, Shiv Kumar

    2017-03-01

    Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert ® has recently been released. Comparative analysis between performances of GeneXpert ® and Abbott HCV-RNA was done. 174 HCV infected patients were recruited and, one time plasma samples from 154 patients and repeated samples from 20 patients, obtained at specific treatment time-points (0, 4, 12 and 24) weeks were serially re-tested on Xpert ® . Genotype 3 was the commonest, seen in 80 (66%) of the cases, genotype 1 in 34 (28.3%), genotype 4 in 4 (3.3%) and genotypes 2 and 5 in 1 (0.8%) each. Median HCV RNA load was 4.69 log 10 (range: 0-6.98log 10 ) IU/ml. Overall a very good correlation was seen between the two assays (R 2 =0.985), concordance of the results between the assays was seen in 138 samples (89.6%). High and low positive standards were tested ten times on Xpert ® to evaluate the precision and the coefficient of variation was 0.01 for HPC and 0.07 for the LPC. Monitoring of patients on two different regimes of treatment, pegylated interferon plus ribavirin and sofosbuvir plus ribavirin was done by both the systems at baseline, 4, 12 and 24 weeks. Perfect correlation between the assays in the course of therapy at different treatment time- point in genotypes 3 and 1 was seen. The study demonstrates excellent performance of the Xpert ® HCV assay in viral load assessment and in treatment course monitoring consistency. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Speed of recovery after arthroscopic rotator cuff repair.

    PubMed

    Kurowicki, Jennifer; Berglund, Derek D; Momoh, Enesi; Disla, Shanell; Horn, Brandon; Giveans, M Russell; Levy, Jonathan C

    2017-07-01

    The purpose of this study was to delineate the time taken to achieve maximum improvement (plateau of recovery) and the degree of recovery observed at various time points (speed of recovery) for pain and function after arthroscopic rotator cuff repair. An institutional shoulder surgery registry query identified 627 patients who underwent arthroscopic rotator cuff repair between 2006 and 2015. Measured range of motion, patient satisfaction, and patient-reported outcome measures were analyzed for preoperative, 3-month, 6-month, 1-year, and 2-year intervals. Subgroup analysis was performed on the basis of tear size by retraction grade and number of anchors used. As an entire group, the plateau of maximum recovery for pain, function, and motion occurred at 1 year. Satisfaction with surgery was >96% at all time points. At 3 months, 74% of improvement in pain and 45% to 58% of functional improvement were realized. However, only 22% of elevation improvement was achieved (P < .001). At 6 months, 89% of improvement in pain, 81% to 88% of functional improvement, and 78% of elevation improvement were achieved (P < .001). Larger tears had a slower speed of recovery for Single Assessment Numeric Evaluation scores, forward elevation, and external rotation. Smaller tears had higher motion and functional scores across all time points. Tear size did not influence pain levels. The plateau of maximum recovery after rotator cuff repair occurred at 1 year with high satisfaction rates at all time points. At 3 months, approximately 75% of pain relief and 50% of functional recovery can be expected. Larger tears have a slower speed of recovery. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Development of a Standard Platinum Resistance Thermometer for Use up to the Copper Point

    NASA Astrophysics Data System (ADS)

    Tavener, J. P.

    2015-08-01

    The international temperature scale of 1990 defines temperatures in the range from 13.8 K to 1234.93 K () using a standard platinum resistance thermometer (SPRT) as an interpolating instrument. For temperatures above , the current designs of an SPRT require extreme care to avoid contamination, especially by metallic impurities, which can cause rapid and irreversible drift. This study investigates the performance of a new design of a high-temperature SPRT with the aim of improving the stability of the SPRTs and extending their temperature range. The prototype SPRTs have an alumina sheath, a sapphire support for the sensing element, which are aspirated with dry air and operated with a dc bias voltage to suppress the diffusion of metal-ion contaminants. Three prototype thermometers were exposed to temperatures near or above the copper freezing point, , for total exposure times in excess of 500 h and exhibited drifts in the triple-point resistance of less than 10 mK. The new design eliminates some of the problems associated with fused-silica sheaths and sensor-support structures and is a viable option for a high-accuracy thermometer for temperatures approaching.

  8. D Data Acquisition Based on Opencv for Close-Range Photogrammetry Applications

    NASA Astrophysics Data System (ADS)

    Jurjević, L.; Gašparović, M.

    2017-05-01

    Development of the technology in the area of the cameras, computers and algorithms for 3D the reconstruction of the objects from the images resulted in the increased popularity of the photogrammetry. Algorithms for the 3D model reconstruction are so advanced that almost anyone can make a 3D model of photographed object. The main goal of this paper is to examine the possibility of obtaining 3D data for the purposes of the close-range photogrammetry applications, based on the open source technologies. All steps of obtaining 3D point cloud are covered in this paper. Special attention is given to the camera calibration, for which two-step process of calibration is used. Both, presented algorithm and accuracy of the point cloud are tested by calculating the spatial difference between referent and produced point clouds. During algorithm testing, robustness and swiftness of obtaining 3D data is noted, and certainly usage of this and similar algorithms has a lot of potential in the real-time application. That is the reason why this research can find its application in the architecture, spatial planning, protection of cultural heritage, forensic, mechanical engineering, traffic management, medicine and other sciences.

  9. Point-of-care ultrasound facilitates diagnosing a posterior shoulder dislocation.

    PubMed

    Mackenzie, David C; Liebmann, Otto

    2013-05-01

    Posterior shoulder dislocation is an uncommon disruption of the glenohumeral joint. Risk factors include seizure, electric shock, and underlying instabilities of the shoulder joint. A 27-year-old man with a history of recurrent posterior shoulder dislocation presented to the Emergency Department with sudden shoulder pain and reduced range of motion about the shoulder after abducting and internally rotating his arm. Radiographs did not show fracture or dislocation. The treating physician suspected an occult posterior shoulder dislocation, but wanted to avoid performing a computed tomography scan of the shoulder, as the patient had undergone numerous scans during the evaluation of similar complaints. Instead, a point-of-care ultrasound was performed, demonstrating posterior displacement of the humeral head relative to the glenoid rim, confirming the presence of a posterior shoulder dislocation. The patient received procedural sedation, and the shoulder was reduced with real-time ultrasound visualization. The patient tolerated the procedure well, and had decreased pain and improved range of motion. He was discharged with a sling, swathe, and orthopedic follow-up. Point-of-care ultrasound of the shoulder may be used to demonstrate posterior shoulder dislocation. This may have particular utility in the setting of non-diagnostic radiographs. Copyright © 2013. Published by Elsevier Inc.

  10. General error analysis in the relationship between free thyroxine and thyrotropin and its clinical relevance.

    PubMed

    Goede, Simon L; Leow, Melvin Khee-Shing

    2013-01-01

    This treatise investigates error sources in measurements applicable to the hypothalamus-pituitary-thyroid (HPT) system of analysis for homeostatic set point computation. The hypothalamus-pituitary transfer characteristic (HP curve) describes the relationship between plasma free thyroxine [FT4] and thyrotropin [TSH]. We define the origin, types, causes, and effects of errors that are commonly encountered in TFT measurements and examine how we can interpret these to construct a reliable HP function for set point establishment. The error sources in the clinical measurement procedures are identified and analyzed in relation to the constructed HP model. The main sources of measurement and interpretation uncertainties are (1) diurnal variations in [TSH], (2) TFT measurement variations influenced by timing of thyroid medications, (3) error sensitivity in ranges of [TSH] and [FT4] (laboratory assay dependent), (4) rounding/truncation of decimals in [FT4] which in turn amplify curve fitting errors in the [TSH] domain in the lower [FT4] range, (5) memory effects (rate-independent hysteresis effect). When the main uncertainties in thyroid function tests (TFT) are identified and analyzed, we can find the most acceptable model space with which we can construct the best HP function and the related set point area.

  11. Automated external defibrillators and simulated in-hospital cardiac arrests.

    PubMed

    Rossano, Joseph W; Jefferson, Larry S; Smith, E O'Brian; Ward, Mark A; Mott, Antonio R

    2009-05-01

    To test the hypothesis that pediatric residents would have shorter time to attempted defibrillation using automated external defibrillators (AEDs) compared with manual defibrillators (MDs). A prospective, randomized, controlled trial of AEDs versus MDs was performed. Pediatric residents responded to a simulated in-hospital ventricular fibrillation cardiac arrest and were randomized to using either an AED or MD. The primary end point was time to attempted defibrillation. Sixty residents, 21 (35%) interns, were randomized to 2 groups (AED = 30, MD = 30). Residents randomized to the AED group had a significantly shorter time to attempted defibrillation [median, 60 seconds (interquartile range, 53 to 71 seconds)] compared with those randomized to the MD group [median, 103 seconds (interquartile range, 68 to 288 seconds)] (P < .001). All residents in the AED group attempted defibrillation at <5 minutes compared with 23 (77%) in the MD group (P = .01). AEDs improve the time to attempted defibrillation by pediatric residents in simulated cardiac arrests. Further studies are needed to help determine the role of AEDs in pediatric in-hospital cardiac arrests.

  12. Real-time terahertz digital holography with a quantum cascade laser

    PubMed Central

    Locatelli, Massimiliano; Ravaro, Marco; Bartalini, Saverio; Consolino, Luigi; Vitiello, Miriam S.; Cicchi, Riccardo; Pavone, Francesco; De Natale, Paolo

    2015-01-01

    Coherent imaging in the THz range promises to exploit the peculiar capabilities of these wavelengths to penetrate common materials like plastics, ceramics, paper or clothes with potential breakthroughs in non-destructive inspection and quality control, homeland security and biomedical applications. Up to now, however, THz coherent imaging has been limited by time-consuming raster scanning, point-like detection schemes and by the lack of adequate coherent sources. Here, we demonstrate real-time digital holography (DH) at THz frequencies exploiting the high spectral purity and the mW output power of a quantum cascade laser combined with the high sensitivity and resolution of a microbolometric array. We show that, in a one-shot exposure, phase and amplitude information of whole samples, either in reflection or in transmission, can be recorded. Furthermore, a 200 times reduced sensitivity to mechanical vibrations and a significantly enlarged field of view are observed, as compared to DH in the visible range. These properties of THz DH enable unprecedented holographic recording of real world dynamic scenes. PMID:26315647

  13. A simple and fast representation space for classifying complex time series

    NASA Astrophysics Data System (ADS)

    Zunino, Luciano; Olivares, Felipe; Bariviera, Aurelio F.; Rosso, Osvaldo A.

    2017-03-01

    In the context of time series analysis considerable effort has been directed towards the implementation of efficient discriminating statistical quantifiers. Very recently, a simple and fast representation space has been introduced, namely the number of turning points versus the Abbe value. It is able to separate time series from stationary and non-stationary processes with long-range dependences. In this work we show that this bidimensional approach is useful for distinguishing complex time series: different sets of financial and physiological data are efficiently discriminated. Additionally, a multiscale generalization that takes into account the multiple time scales often involved in complex systems has been also proposed. This multiscale analysis is essential to reach a higher discriminative power between physiological time series in health and disease.

  14. Guidance, Navigation, and Control Performance for the GOES-R Spacecraft

    NASA Technical Reports Server (NTRS)

    Chapel, Jim; Stancliffe, Devin; Bevacqua, TIm; Winkler, Stephen; Clapp, Brian; Rood, Tim; Gaylor, David; Freesland, Doug; Krimchansky, Alexander

    2014-01-01

    The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites. The series represents a dramatic increase in Earth observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands. GOES-R also provides unprecedented availability, with less than 120 minutes per year of lost observation time. This paper presents the Guidance Navigation & Control (GN&C) requirements necessary to realize the ambitious pointing, knowledge, and Image Navigation and Registration (INR) objectives of GOES-R. Because the suite of instruments is sensitive to disturbances over a broad spectral range, a high fidelity simulation of the vehicle has been created with modal content over 500 Hz to assess the pointing stability requirements. Simulation results are presented showing acceleration, shock response spectra (SRS), and line of sight (LOS) responses for various disturbances from 0 Hz to 512 Hz. Simulation results demonstrate excellent performance relative to the pointing and pointing stability requirements, with LOS jitter for the isolated instrument platform of approximately 1 micro-rad. Attitude and attitude rate knowledge are provided directly to the instrument with an accuracy defined by the Integrated Rate Error (IRE) requirements. The data are used internally for motion compensation. The final piece of the INR performance is orbit knowledge, which GOES-R achieves with GPS navigation. Performance results are shown demonstrating compliance with the 50 to 75 m orbit position accuracy requirements. As presented in this paper, the GN&C performance supports the challenging mission objectives of GOES-R.

  15. Child care choices, food intake, and children's obesity status in the United States.

    PubMed

    Mandal, Bidisha; Powell, Lisa M

    2014-07-01

    This article studies two pathways in which selection into different types of child care settings may affect likelihood of childhood obesity. Frequency of intake of high energy-dense and low energy-dense food items may vary across care settings, affecting weight outcomes. We find that increased use of paid and regulated care settings, such as center care and Head Start, is associated with higher consumption of fruits and vegetables. Among children from single-mother households, the probability of obesity increases by 15 percentage point with an increase in intake of soft drinks from four to six times a week to daily consumption and by 25 percentage point with an increase in intake of fast food from one to three times a week to four to six times a week. Among children from two-parent households, eating vegetables one additional time a day is associated with 10 percentage point decreased probability of obesity, while one additional drink of juice a day is associated with 10 percentage point increased probability of obesity. Second, variation across care types could be manifested through differences in the structure of the physical environment not captured by differences in food intake alone. This type of effect is found to be marginal and is statistically significant among children from two-parent households only. Data are used from the Early Childhood Longitudinal Study - Birth Cohort surveys (N=10,700; years=2001-2008). Children's age ranged from four to six years in the sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Parallel algorithm for determining motion vectors in ice floe images by matching edge features

    NASA Technical Reports Server (NTRS)

    Manohar, M.; Ramapriyan, H. K.; Strong, J. P.

    1988-01-01

    A parallel algorithm is described to determine motion vectors of ice floes using time sequences of images of the Arctic ocean obtained from the Synthetic Aperture Radar (SAR) instrument flown on-board the SEASAT spacecraft. Researchers describe a parallel algorithm which is implemented on the MPP for locating corresponding objects based on their translationally and rotationally invariant features. The algorithm first approximates the edges in the images by polygons or sets of connected straight-line segments. Each such edge structure is then reduced to a seed point. Associated with each seed point are the descriptions (lengths, orientations and sequence numbers) of the lines constituting the corresponding edge structure. A parallel matching algorithm is used to match packed arrays of such descriptions to identify corresponding seed points in the two images. The matching algorithm is designed such that fragmentation and merging of ice floes are taken into account by accepting partial matches. The technique has been demonstrated to work on synthetic test patterns and real image pairs from SEASAT in times ranging from .5 to 0.7 seconds for 128 x 128 images.

  17. The Sea Level Rise Tipping Point of Delta Survival

    NASA Astrophysics Data System (ADS)

    Turner, R. E.; Kearney, M.; Parkinson, R. W.

    2017-12-01

    The estimated rate of global eustatic sea-level rise (RSLR) associated with the formation of thirty-six of the world's coastal deltas was calculated for the last 22,000 years. These deltas are located in a variety of environmental settings in respect to tidal range, isostasy, and climate. After correcting the original uncalibrated radiocarbon age estimates to calibrated years, 90% of the deltas appear to have formed at an average age of 8,109 ± 122 BP and a median age of 7,967 BP. This age corresponds to a period of significant deceleration in the RSLR to between 5 mm yr-1 and 10 mm yr-1, and is in agreement with two regional estimates of vegetation growth limits with respect to RSLR. This RSLR tipping point for delta formation can be used to inform forecasts of delta resiliency under conditions of climate change and concomitant sea level rise. The RSLR is accelerating and will likely be several times higher than the formation tipping point by the end of this century. Hence, the demise of the world's deltaic environments are likely to occur within the same time frame.

  18. Avoiding Obstructions in Aiming a High-Gain Antenna

    NASA Technical Reports Server (NTRS)

    Edmonds, Karina

    2006-01-01

    The High Gain Antenna Pointing and Obstruction Avoidance software performs computations for pointing a Mars Rover high-gain antenna for communication with Earth while (1) avoiding line-of-sight obstructions (the Martian terrain and other parts of the Rover) that would block communication and (2) taking account of limits in ranges of motion of antenna gimbals and of kinematic singularities in gimbal mechanisms. The software uses simplified geometric models of obstructions and of the trajectory of the Earth in the Martian sky(see figure). It treats all obstructions according to a generalized approach, computing and continually updating the time remaining before interception of each obstruction. In cases in which the gimbal-mechanism design allows two aiming solutions, the algorithm chooses the solution that provides the longest obstruction-free Earth-tracking time. If the communication session continues until an obstruction is encountered in the current pointing solution and the other solution is now unobstructed, then the algorithm automatically switches to the other position. This software also notifies communication- managing software to cease transmission during the switch to the unobstructed position, resuming it when the switch is complete.

  19. Apparatus and method for mapping an area of interest

    DOEpatents

    Staab, Torsten A. Cohen, Daniel L.; Feller, Samuel [Fairfax, VA

    2009-12-01

    An apparatus and method are provided for mapping an area of interest using polar coordinates or Cartesian coordinates. The apparatus includes a range finder, an azimuth angle measuring device to provide a heading and an inclinometer to provide an angle of inclination of the range finder as it relates to primary reference points and points of interest. A computer is provided to receive signals from the range finder, inclinometer and azimuth angle measurer to record location data and calculate relative locations between one or more points of interest and one or more primary reference points. The method includes mapping of an area of interest to locate points of interest relative to one or more primary reference points and to store the information in the desired manner. The device may optionally also include an illuminator which can be utilized to paint the area of interest to indicate both points of interest and primary points of reference during and/or after data acquisition.

  20. Realization of the Temperature Scale in the Range from 234.3 K (Hg Triple Point) to 1084.62°C (Cu Freezing Point) in Croatia

    NASA Astrophysics Data System (ADS)

    Zvizdic, Davor; Veliki, Tomislav; Grgec Bermanec, Lovorka

    2008-06-01

    This article describes the realization of the International Temperature Scale in the range from 234.3 K (mercury triple point) to 1084.62°C (copper freezing point) at the Laboratory for Process Measurement (LPM), Faculty of Mechanical Engineering and Naval Architecture (FSB), University of Zagreb. The system for the realization of the ITS-90 consists of the sealed fixed-point cells (mercury triple point, water triple point and gallium melting point) and the apparatus designed for the optimal realization of open fixed-point cells which include the gallium melting point, tin freezing point, zinc freezing point, aluminum freezing point, and copper freezing point. The maintenance of the open fixed-point cells is described, including the system for filling the cells with pure argon and for maintaining the pressure during the realization.

  1. Method and apparatus for determining material structural integrity

    DOEpatents

    Pechersky, Martin

    1996-01-01

    A non-destructive method and apparatus for determining the structural integrity of materials by combining laser vibrometry with damping analysis techniques to determine the damping loss factor of a material. The method comprises the steps of vibrating the area being tested over a known frequency range and measuring vibrational force and velocity as a function of time over the known frequency range. Vibrational velocity is preferably measured by a laser vibrometer. Measurement of the vibrational force depends on the vibration method. If an electromagnetic coil is used to vibrate a magnet secured to the area being tested, then the vibrational force is determined by the amount of coil current used in vibrating the magnet. If a reciprocating transducer is used to vibrate a magnet secured to the area being tested, then the vibrational force is determined by a force gauge in the reciprocating transducer. Using known vibrational analysis methods, a plot of the drive point mobility of the material over the preselected frequency range is generated from the vibrational force and velocity measurements. The damping loss factor is derived from a plot of the drive point mobility over the preselected frequency range using the resonance dwell method and compared with a reference damping loss factor for structural integrity evaluation.

  2. Sea otters are recolonizing southern California in fits and starts

    USGS Publications Warehouse

    Lafferty, Kevin D.; Tinker, M. Tim

    2014-01-01

    After near extinction as a result of the fur trade in the 1700s and 1800s, the southern sea otter slowly reoccupied the core of its range in central California. Range expansion beyond central California is seen as key to full recovery of otters, but the rate of expansion has been sporadic, raising concerns about habitat quality in southern California. To describe the range expansion of sea otters from central into southern California, we used skiff surveys, aerial surveys, and archival time-depth recorders from 2004 to 2013. These observations show that range expansion began when male otters swam southeast of Point Conception (Cojo Anchorage), perhaps to seek refuge from bad weather and to feed on unexploited resources. After several years of seasonal use by male groups, females began to use the area, leading to reproduction and a secondary increase in abundance. In contrast, a second male group that moved farther down the coast to Coal Oil Point stalled and retreated. Such range expansion and contraction can be explained by the social nature of sea otters, which acts to slow dispersal away from groups. Otter densities at Cojo Anchorage are now approaching equilibrium levels reported for central California. As in central California, otters rested in and near kelp forest habitat, but used deeper water for foraging. Together, these observations suggest habitat in the Santa Barbara Channel can still support sea otters, but range expansion of otters into southern California will be episodic due to social dynamics.

  3. Count Us In. Achieving Success for Deaf Pupils. Practical Examples from Primary, Secondary, and Special Schools

    ERIC Educational Resources Information Center

    Her Majesty's Inspectorate of Education, 2007

    2007-01-01

    "Count Us in: Achieving Success for Deaf Pupils" is a timely report. It comes when schools are becoming more confident in dealing with a wide range of additional support for learning needs. Schools are also more aware that they need to personalise experiences in order to meet pupils' learning needs. The report does point to strengths…

  4. Marital adjustment, satisfaction and dissolution among hematopoietic stem cell transplant patients and spouses: a prospective, five-year longitudinal investigation.

    PubMed

    Langer, Shelby L; Yi, Jean C; Storer, Barry E; Syrjala, Karen L

    2010-02-01

    To examine the trajectory of marital adjustment, satisfaction and dissolution among 121 hematopoietic stem cell transplant (HSCT) couples-as a function of role (patient or spouse) and gender. Prospective, longitudinal design. Participants completed the Dyadic Adjustment Scale at six time points: pre-transplant (4-7 days after beginning medical workup prior to starting transplant), 6 months post-transplant, and 1, 2, 3 and 5 years post-transplant. They also reported on marital status over time. Participants ranged in age from 23-68 (52% female patients and 48% female spouses). Ninety-eight patients received an allogeneic transplant; 23 received an autologous transplant. Marital dissolution was uncommon (four divorces since the transplant among 55 participating 5-year survivors, 7%). Dyadic satisfaction was stable over time for both male and female patients and male spouses, but not for female spouses who reported reductions in satisfaction at all time points relative to baseline. Couples were by and large resilient. However, caregiver-specific gender differences indicate an increased risk for relationship maladjustment and dissatisfaction among female spouses and ultimately, female spouse/male patient couples.

  5. SU-F-P-46: Comparative Study Between Two Normalization Prescriptions for Accelerated Partial Breast Irradiation: A Dosimetric Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, P; Sharma, D; Gandhi, A

    2016-06-15

    Purpose: To compare the Accelerated Partial Breast Irradiation (APBI) plan with the normalized basal dose points and 5mm box prescription. Methods: Five patients of APBI were planned twice in Oncentra Master planning TPS (Version 4.3) using TG-43 algorithm. The number of catheters for all the patients was 10 to 16 and implant plane 2 to 3. For planning all catheters were reconstructed. Source loading was done as per HR-CTV contoured. The HR-CTV volume range was from 75cc to 182cc. Plans were normalized in two methods. First all plans were normalized on Basal dose points (PlanA) and second all the planmore » were normalized on 5mm box (PlanB). The prescription dose (PD) was 35Gy in 10 fractions. All the plans were completely based on normalization and without optimization. Plan evaluation was based on certain parameters coverage Index (CI), dose homogeneity index (DHI), conformity index (COIN), over dose volume index (OI). Results: The average and median of CI for planA was 0.835 and 0.8154, for planB 0.82 and 0.799 respectively. The median and average of DHI for planA was 0.66 and 0.6062, for planB 0.67 and 0.62 respectively. The range of COIN for planA and planB was from 0.58 to 0.65 respectively. The range of OI was from 0.083 to 0.169 for planA and planB. The treatment time in planA was in average 1.13 times more than planB as V150% of HR-CTV in planA was 4–6% more. The ipsilateral lung was getting 30% of PD which was 0.6% to 3.5%. Conclusion: Treatment Planning should be individualized based on implants characteristics. Planning with prescription to basal dose points should be preferred to 5mm box prescription, in order to achieve better DHI and less treatment time.« less

  6. Hydronephrosis in patients with cervical cancer: an assessment of morbidity and survival

    PubMed Central

    Patel, Krishna; Foster, Nathan R.; Kumar, Amanika; Grudem, Megan; Longenbach, Sherri; Bakkum-Gamez, Jamie; Haddock, Michael; Dowdy, Sean; Jatoi, Aminah

    2015-01-01

    Purpose Hydronephrosis is a frequently observed but understudied complication in patients with cervical cancer. To better characterize hydronephrosis in cervical cancer patients, the current study sought (1) to describe hydronephrosis-associated morbidity and (2) to analyze the prognostic effect of hydronephrosis in patients with a broad range of cancer stages over time. Methods The Mayo Clinic Tumor Registry was interrogated for all invasive cervical cancer patients seen at the Mayo Clinic from 2008 through 2013 in Rochester, Minnesota; these patients’ medical records were then reviewed in detail. Results Two hundred seventy-nine cervical cancer patients with a median age of 49 years and a range of cancer stages were included. Sixty-five patients (23 %) were diagnosed with hydronephrosis at some point during their disease course. In univariate analyses, hydronephrosis was associated with advanced cancer stage (p<0.0001), squamous histology (p=0.0079), and nonsurgical cancer treatment (p=0.0039). In multivariate analyses, stage and tumor histology were associated with hydronephrosis. All but one patient underwent stent placement or urinary diversion; hydronephrosis-related morbidity included pain, urinary tract infections, nausea and vomiting, renal failure, and urinary tract bleeding. In landmark univariate survival analyses, hydronephrosis was associated with worse survival at all time points. In landmark multivariate analyses (adjusted for patient age, stage, cancer treatment, and tumor histology), hydronephrosis was associated with a trend toward worse survival over time (hazard ratios ranged from 1.47 to 4.69). Conclusion Hydronephrosis in cervical cancer patients is associated with notable morbidity. It is also associated with trends toward worse survival—even if it occurs after the original cancer diagnosis. PMID:25339620

  7. Randomized Hough transform filter for echo extraction in DLR

    NASA Astrophysics Data System (ADS)

    Liu, Tong; Chen, Hao; Shen, Ming; Gao, Pengqi; Zhao, You

    2016-11-01

    The signal-to-noise ratio (SNR) of debris laser ranging (DLR) data is extremely low, and the valid returns in the DLR range residuals are distributed on a curve in a long observation time. Therefore, it is hard to extract the signals from noise in the Observed-minus-Calculated (O-C) residuals with low SNR. In order to autonomously extract the valid returns, we propose a new algorithm based on randomized Hough transform (RHT). We firstly pre-process the data using histogram method to find the zonal area that contains all the possible signals to reduce large amount of noise. Then the data is processed with RHT algorithm to find the curve that the signal points are distributed on. A new parameter update strategy is introduced in the RHT to get the best parameters. We also analyze the values of the parameters in the algorithm. We test our algorithm on the 10 Hz repetition rate DLR data from Yunnan Observatory and 100 Hz repetition rate DLR data from Graz SLR station. For 10 Hz DLR data with relative larger and similar range gate, we can process it in real time and extract all the signals autonomously with a few false readings. For 100 Hz DLR data with longer observation time, we autonomously post-process DLR data of 0.9%, 2.7%, 8% and 33% return rate with high reliability. The extracted points contain almost all signals and a low percentage of noise. Additional noise is added to 10 Hz DLR data to get lower return rate data. The valid returns can also be well extracted for DLR data with 0.18% and 0.1% return rate.

  8. Exposure to radio frequency electromagnetic fields from wireless computer networks: duty factors of Wi-Fi devices operating in schools.

    PubMed

    Khalid, M; Mee, T; Peyman, A; Addison, D; Calderon, C; Maslanyj, M; Mann, S

    2011-12-01

    The growing use of wireless local area networks (WLAN) in schools has prompted a study to investigate exposure to the radio frequency (RF) electromagnetic fields from Wi-Fi devices. International guidelines on limiting the adverse health effects of RF, such as those of ICNIRP, allow for time-averaging of exposure. Thus, as Wi-Fi signals consist of intermittent bursts of RF energy, it is important to consider the duty factors of devices in assessing the extent of exposure and compliance with guidelines. Using radio packet capture methods, the duty factor of Wi-Fi devices has been assessed in a sample of 6 primary and secondary schools during classroom lessons. For the 146 individual laptops investigated, the range of duty factors was from 0.02 to 0.91%, with a mean of 0.08% (SD 0.10%). The duty factors of access points from 7 networks ranged from 1.0% to 11.7% with a mean of 4.79% (SD 3.76%). Data gathered with transmit time measuring devices attached to laptops also showed similar results. Within the present limited sample, the range of duty factors from laptops and access points were found to be broadly similar for primary and secondary schools. Applying these duty factors to previously published results from this project, the maximum time-averaged power density from a laptop would be 220 μW m(-2), at a distance of 0.5 m and the peak localised SAR predicted in the torso region of a 10 year old child model, at 34 cm from the antenna, would be 80 μW kg(-1). Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

  9. A Text Message Delivered Smoking Cessation Intervention: The Initial Trial of TXT-2-Quit: Randomized Controlled Trial

    PubMed Central

    2013-01-01

    Background Mobile technology offers the potential to deliver health-related interventions to individuals who would not otherwise present for in-person treatment. Text messaging (short message service, SMS), being the most ubiquitous form of mobile communication, is a promising method for reaching the most individuals. Objective The goal of the present study was to evaluate the feasibility and preliminary efficacy of a smoking cessation intervention program delivered through text messaging. Methods Adult participants (N=60, age range 18-52 years) took part in a single individual smoking cessation counseling session, and were then randomly assigned to receive either daily non-smoking related text messages (control condition) or the TXT-2-Quit (TXT) intervention. TXT consisted of automated smoking cessation messages tailored to individual’s stage of smoking cessation, specialized messages provided on-demand based on user requests for additional support, and a peer-to-peer social support network. Generalized estimating equation analysis was used to assess the primary outcome (7-day point-prevalence abstinence) using a 2 (treatment groups)×3 (time points) repeated measures design across three time points: 8 weeks, 3 months, and 6 months. Results Smoking cessation results showed an overall significant group difference in 7-day point prevalence abstinence across all follow-up time points. Individuals given the TXT intervention, with higher odds of 7-day point prevalence abstinence for the TXT group compared to the Mojo group (OR=4.52, 95% CI=1.24, 16.53). However, individual comparisons at each time point did not show significant between-group differences, likely due to reduced statistical power. Intervention feasibility was greatly improved by switching from traditional face-to-face recruitment methods (4.7% yield) to an online/remote strategy (41.7% yield). Conclusions Although this study was designed to develop and provide initial testing of the TXT-2-Quit system, these initial findings provide promising evidence that a text-based intervention can be successfully implemented with a diverse group of adult smokers. Trial Registration ClinicalTrials.gov: NCT01166464; http://clinicaltrials.gov/ct2/show/NCT01166464 (Archived by WebCite at http://www.webcitation.org/6IOE8XdE0). PMID:25098502

  10. Efficient geometric rectification techniques for spectral analysis algorithm

    NASA Technical Reports Server (NTRS)

    Chang, C. Y.; Pang, S. S.; Curlander, J. C.

    1992-01-01

    The spectral analysis algorithm is a viable technique for processing synthetic aperture radar (SAR) data in near real time throughput rates by trading the image resolution. One major challenge of the spectral analysis algorithm is that the output image, often referred to as the range-Doppler image, is represented in the iso-range and iso-Doppler lines, a curved grid format. This phenomenon is known to be the fanshape effect. Therefore, resampling is required to convert the range-Doppler image into a rectangular grid format before the individual images can be overlaid together to form seamless multi-look strip imagery. An efficient algorithm for geometric rectification of the range-Doppler image is presented. The proposed algorithm, realized in two one-dimensional resampling steps, takes into consideration the fanshape phenomenon of the range-Doppler image as well as the high squint angle and updates of the cross-track and along-track Doppler parameters. No ground reference points are required.

  11. Centroid tracker and aimpoint selection

    NASA Astrophysics Data System (ADS)

    Venkateswarlu, Ronda; Sujata, K. V.; Venkateswara Rao, B.

    1992-11-01

    Autonomous fire and forget weapons have gained importance to achieve accurate first pass kill by hitting the target at an appropriate aim point. Centroid of the image presented by a target in the field of view (FOV) of a sensor is generally accepted as the aimpoint for these weapons. Centroid trackers are applicable only when the target image is of significant size in the FOV of the sensor but does not overflow the FOV. But as the range between the sensor and the target decreases the image of the target will grow and finally overflow the FOV at close ranges and the centroid point on the target will keep on changing which is not desirable. And also centroid need not be the most desired/vulnerable point on the target. For hardened targets like tanks, proper aimpoint selection and guidance up to almost zero range is essential to achieve maximum kill probability. This paper presents a centroid tracker realization. As centroid offers a stable tracking point, it can be used as a reference to select the proper aimpoint. The centroid and the desired aimpoint are simultaneously tracked to avoid jamming by flares and also to take care of the problems arising due to image overflow. Thresholding of gray level image to binary image is a crucial step in centroid tracker. Different thresholding algorithms are discussed and a suitable algorithm is chosen. The real-time hardware implementation of centroid tracker with a suitable thresholding technique is presented including the interfacing to a multimode tracker for autonomous target tracking and aimpoint selection. The hardware uses very high speed arithmetic and programmable logic devices to meet the speed requirement and a microprocessor based subsystem for the system control. The tracker has been evaluated in a field environment.

  12. Temperature Preference in IAF Hairless and Hartley Guinea Pigs (Cavia porcellus)

    PubMed Central

    Kleven, Gale A; Joshi, Prianca

    2016-01-01

    The Hairless strain of guinea pigs (Cavia porcellus) is the result of a spontaneous recessive mutation first identified at the Institute Armand Frappier (IAF) in 1978. Despite the longstanding availability of this strain, little is known about its thermoregulatory behavior. The aim of this study was to determine temperature preference in Hartley and Hairless guinea pigs by observing each strain in a ring-shaped apparatus containing a nonlinear temperature gradient. Temperatures were maintained by separately controlled heating mats lining the apparatus. Set point temperatures ranged from 24 to 38 °C. Guinea pigs (Hartley female, Hairless female, and Hairless male guinea pigs; n = 8 each group) were placed either singly or in pairs at 1 of the 8 randomized starting points within the apparatus. Subjects were observed for 30 min and coded for location within the temperature gradient by both frequency and duration. When placed singly in the apparatus, all 3 groups spent more time in the 30 °C zones. However, when placed as pairs with a cagemate, Hartley female guinea pigs spent more time in the cooler range of temperatures from 24 to 30 °C, whereas Hairless guinea pigs preferred a range of 30 to 38 °C. These results confirm a temperature preference of 30 ± 2 °C for both Hartley and Hairless guinea pigs when singly housed. However, data from the paired housing condition suggest that context plays an important role in thermoregulatory behavior. PMID:27025807

  13. Imaging synthetic aperture radar

    DOEpatents

    Burns, Bryan L.; Cordaro, J. Thomas

    1997-01-01

    A linear-FM SAR imaging radar method and apparatus to produce a real-time image by first arranging the returned signals into a plurality of subaperture arrays, the columns of each subaperture array having samples of dechirped baseband pulses, and further including a processing of each subaperture array to obtain coarse-resolution in azimuth, then fine-resolution in range, and lastly, to combine the processed subapertures to obtain the final fine-resolution in azimuth. Greater efficiency is achieved because both the transmitted signal and a local oscillator signal mixed with the returned signal can be varied on a pulse-to-pulse basis as a function of radar motion. Moreover, a novel circuit can adjust the sampling location and the A/D sample rate of the combined dechirped baseband signal which greatly reduces processing time and hardware. The processing steps include implementing a window function, stabilizing either a central reference point and/or all other points of a subaperture with respect to doppler frequency and/or range as a function of radar motion, sorting and compressing the signals using a standard fourier transforms. The stabilization of each processing part is accomplished with vector multiplication using waveforms generated as a function of radar motion wherein these waveforms may be synthesized in integrated circuits. Stabilization of range migration as a function of doppler frequency by simple vector multiplication is a particularly useful feature of the invention; as is stabilization of azimuth migration by correcting for spatially varying phase errors prior to the application of an autofocus process.

  14. Factors predicting change in hospital safety climate and capability in a multi-site patient safety collaborative: a longitudinal survey study.

    PubMed

    Benn, Jonathan; Burnett, Susan; Parand, Anam; Pinto, Anna; Vincent, Charles

    2012-07-01

    The study had two specific objectives: (1) To analyse change in a survey measure of organisational patient safety climate and capability (SCC) resulting from participation in the UK Safer Patients Initiative and (2) To investigate the role of a range of programme and contextual factors in predicting change in SCC scores. Single group longitudinal design with repeated measurement at 12-month follow-up. Multiple service areas within NHS hospital sites across England, Wales, Scotland and Northern Ireland. Stratified sample of 284 respondents representing programme teams at 19 hospital sites. A complex intervention comprising a multi-component quality improvement collaborative focused upon patient safety and designed to impact upon hospital leadership, communication, organisation and safety climate. A survey including a 31-item SCC scale was administered at two time-points. Modest but significant positive movement in SCC score was observed between the study time-points. Individual programme responsibility, availability of early adopters, multi-professional collaboration and extent of process measurement were significant predictors of change in SCC. Hospital type and size, along with a range of programme preconditions, were not found to be significant. A range of social, cultural and organisational factors may be sensitive to this type of intervention but the measurable effect is small. Supporting critical local programme implementation factors may be an effective strategy in achieving development in organisational patient SCC, regardless of contextual factors and organisational preconditions.

  15. Variation in water disappearance, daily dose, and synovial fluid concentrations of tylvalosin and 3-O-acetyltylosin in commerical pigs during five day water medication with tylvalosin under field conditions.

    PubMed

    Canning, P; Bates, J; Skoland, K; Coetzee, J; Wulf, L; Rajewski, S; Wang, C; Gauger, P; Ramirez, A; Karriker, L

    2018-03-23

    Tylvalosin (TVN) is a water soluble macrolide used in swine production to treat enteric, respiratory, and arthritic pathogens. There is limited data on its distribution to synovial fluid beyond gavage studies, which do not represent field conditions. This study measured water disappearance, TVN concentration in the medicated water, daily dose, and concentrations of TVN and 3-O-acetyltylosin (3AT) in the synovial fluid and plasma of treated pigs over the administration period. The study emphasized understanding variation in tissue TVN concentrations within the context of a field setting. Sixty finisher pigs were housed individually with individual waterers. Six pigs were randomly allocated to the following time points for sample collection: 0, 48, 60, 72, 84, 96, 102, 108, 114, and 120 hr on medication. TVN was administered daily in the water for 5 days. Water disappearance and medicated water concentration were measured daily. At each time point, six pigs were euthanized and plasma and synovial fluid were collected for analysis. Median TVN synovial fluid concentrations ranged between <1 ng/ml (hour 0) to 3.6 ng/ml (hour 84). There was substantial variation between individual pigs for water disappearance (mean 4.36L and range 0-7.84). Median TVN water concentration was 59 ppm (range 38-75 ppm). © 2018 John Wiley & Sons Ltd.

  16. Exploring the variation of oral microbiota in supragingival plaque during and after head-and-neck radiotherapy using pyrosequencing.

    PubMed

    Gao, Li; Hu, Yuejian; Wang, Yuxia; Jiang, Wenxin; He, Zhiyan; Zhu, Cailian; Ma, Rui; Huang, Zhengwei

    2015-09-01

    The aim of this article was to study the variation in oral microflora of the subgingival plaque during and after radiotherapy. During and after radiotherapy, microbial samples were collected at seven time points (early stage, medium stage, and later stage of radiotherapy, and 1 month, 3 months, 6 months, and 1 year after radiotherapy) in three subjects for a total of 21 samples. Polymerase chain reaction (PCR) amplification was carried out on the 16S rDNA hypervariable V1-V3 region, and then the PCR products were determined by high-throughput pyrosequencing. The rarefaction curve indicating the richness of the microflora demonstrated that the number of operational taxonomic units (OTUs) was in decline from the early stage of radiotherapy to the time point 1 month after radiotherapy and then trended upward. The Shannon diversity index declined during radiotherapy (ranging from 4.59 to 3.73), and generally rose after radiotherapy, with the lowest value of 3.5 (1 month after radiotherapy) and highest value of 4.75 (6 months after radiotherapy). A total of 120 genera were found; five genera (Actinomyces, Veillonella, Prevotella, Streptococcus, Campylobacter) were found in all subjects across all time points. The richness and diversity of oral ecology decreased with increased radiation dose, and it was gradually restored with time. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. More than just tracking time: Complex measures of user engagement with an internet-based health promotion intervention.

    PubMed

    Baltierra, Nina B; Muessig, Kathryn E; Pike, Emily C; LeGrand, Sara; Bull, Sheana S; Hightow-Weidman, Lisa B

    2016-02-01

    There has been a rise in internet-based health interventions without a concomitant focus on new methods to measure user engagement and its effect on outcomes. We describe current user tracking methods for internet-based health interventions and offer suggestions for improvement based on the design and pilot testing of healthMpowerment.org (HMP). HMP is a multi-component online intervention for young Black men and transgender women who have sex with men (YBMSM/TW) to reduce risky sexual behaviors, promote healthy living and build social support. The intervention is non-directive, incorporates interactive features, and utilizes a point-based reward system. Fifteen YBMSM/TW (age 20-30) participated in a one-month pilot study to test the usability and efficacy of HMP. Engagement with the intervention was tracked using a customized data capture system and validated with Google Analytics. Usage was measured in time spent (total and across sections) and points earned. Average total time spent on HMP was five hours per person (range 0-13). Total time spent was correlated with total points earned and overall site satisfaction. Measuring engagement in internet-based interventions is crucial to determining efficacy. Multiple methods of tracking helped derive more comprehensive user profiles. Results highlighted the limitations of measures to capture user activity and the elusiveness of the concept of engagement. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. An adipoinductive role of inflammation in adipose tissue engineering: key factors in the early development of engineered soft tissues.

    PubMed

    Lilja, Heidi E; Morrison, Wayne A; Han, Xiao-Lian; Palmer, Jason; Taylor, Caroline; Tee, Richard; Möller, Andreas; Thompson, Erik W; Abberton, Keren M

    2013-05-15

    Tissue engineering and cell implantation therapies are gaining popularity because of their potential to repair and regenerate tissues and organs. To investigate the role of inflammatory cytokines in new tissue development in engineered tissues, we have characterized the nature and timing of cell populations forming new adipose tissue in a mouse tissue engineering chamber (TEC) and characterized the gene and protein expression of cytokines in the newly developing tissues. EGFP-labeled bone marrow transplant mice and MacGreen mice were implanted with TEC for periods ranging from 0.5 days to 6 weeks. Tissues were collected at various time points and assessed for cytokine expression through ELISA and mRNA analysis or labeled for specific cell populations in the TEC. Macrophage-derived factors, such as monocyte chemotactic protein-1 (MCP-1), appear to induce adipogenesis by recruiting macrophages and bone marrow-derived precursor cells to the TEC at early time points, with a second wave of nonbone marrow-derived progenitors. Gene expression analysis suggests that TNFα, LCN-2, and Interleukin 1β are important in early stages of neo-adipogenesis. Increasing platelet-derived growth factor and vascular endothelial cell growth factor expression at early time points correlates with preadipocyte proliferation and induction of angiogenesis. This study provides new information about key elements that are involved in early development of new adipose tissue.

  19. Prevalence of mental health symptoms in Dutch military personnel returning from deployment to Afghanistan: a 2-year longitudinal analysis.

    PubMed

    Reijnen, A; Rademaker, A R; Vermetten, E; Geuze, E

    2015-02-01

    Recent studies in troops deployed to Iraq and Afghanistan have shown that combat exposure and exposure to deployment-related stressors increase the risk for the development of mental health symptoms. The aim of this study is to assess the prevalence of mental health symptoms in a cohort of Dutch military personnel prior to and at multiple time-points after deployment. Military personnel (n=994) completed various questionnaires at 5 time-points; starting prior to deployment and following the same cohort at 1 and 6 months and 1 and 2 years after their return from Afghanistan. The prevalence of symptoms of fatigue, PTSD, hostility, depression and anxiety was found to significantly increase after deployment compared with pre-deployment rates. As opposed to depressive symptoms and fatigue, the prevalence of PTSD was found to decrease after the 6-month assessment. The prevalence of sleeping problems and hostility remained relatively stable. The prevalence of mental health symptoms in military personnel increases after deployment, however, symptoms progression over time appears to be specific for various mental health symptoms. Comprehensive screening and monitoring for a wide range of mental health symptoms at multiple time-points after deployment is essential for early detection and to provide opportunities for intervention. This project was funded by the Dutch Ministry of Defence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  20. Results of 45 arthroscopic Bankart procedures: Does the ISIS remain a reliable prognostic assessment after 5 years?

    PubMed

    Boughebri, Omar; Maqdes, Ali; Moraiti, Constantina; Dib, Choukry; Leclère, Franck Marie; Valenti, Philippe

    2015-05-01

    The Instability Severity Index Score (ISIS) includes preoperative clinical and radiological risk factors to select patients who can benefit from an arthroscopic Bankart procedure with a low rate of recurrence. Patients who underwent an arthroscopic Bankart for anterior shoulder instability with an ISIS lower than or equal to four were assessed after a minimum of 5-year follow-up. Forty-five shoulders were assessed at a mean of 79 months (range 60-118 months). Average age was 29.4 years (range 17-58 years) at the time of surgery. Postoperative functions were assessed by the Walch and Duplay and the Rowe scores for 26 patients; an adapted telephonic interview was performed for the 19 remaining patients who could not be reassessed clinically. A failure was defined by the recurrence of an anterior dislocation or subluxation. Patients were asked whether they were finally very satisfied, satisfied or unhappy. The mean Walch and Duplay score at last follow-up was 84.3 (range 35-100). The final result for these patients was excellent in 14 patients (53.8 %), good in seven cases (26.9 %), poor in three patients (11.5 %) and bad in two patients (7.7 %). The mean Rowe score was 82.6 (range 35-100). Thirty-nine patients (86.7 %) were subjectively very satisfied or satisfied, and six (13.3 %) were unhappy. Four patients (8.9 %) had a recurrence of frank dislocation with a mean delay of 34 months (range 12-72 months). Three of them had a Hill-Sachs lesion preoperatively. Two patients had a preoperative ISIS at 4 points and two patients at 3 points. The selection based on the ISIS allows a low rate of failure after an average term of 5 years. Lowering the limit for indication to 3 points allows to avoid the association between two major risk factors for recurrence, which are valued at 2 points. The existence of a Hill-Sachs lesion is a stronger indicator for the outcome of instability repair. Level IV, Retrospective Case Series, Treatment Study.

  1. Estimating landscape carrying capacity through maximum clique analysis

    USGS Publications Warehouse

    Donovan, Therese; Warrington, Greg; Schwenk, W. Scott; Dinitz, Jeffrey H.

    2012-01-01

    Habitat suitability (HS) maps are widely used tools in wildlife science and establish a link between wildlife populations and landscape pattern. Although HS maps spatially depict the distribution of optimal resources for a species, they do not reveal the population size a landscape is capable of supporting--information that is often crucial for decision makers and managers. We used a new approach, "maximum clique analysis," to demonstrate how HS maps for territorial species can be used to estimate the carrying capacity, N(k), of a given landscape. We estimated the N(k) of Ovenbirds (Seiurus aurocapillus) and bobcats (Lynx rufus) in an 1153-km2 study area in Vermont, USA. These two species were selected to highlight different approaches in building an HS map as well as computational challenges that can arise in a maximum clique analysis. We derived 30-m2 HS maps for each species via occupancy modeling (Ovenbird) and by resource utilization modeling (bobcats). For each species, we then identified all pixel locations on the map (points) that had sufficient resources in the surrounding area to maintain a home range (termed a "pseudo-home range"). These locations were converted to a mathematical graph, where any two points were linked if two pseudo-home ranges could exist on the landscape without violating territory boundaries. We used the program Cliquer to find the maximum clique of each graph. The resulting estimates of N(k) = 236 Ovenbirds and N(k) = 42 female bobcats were sensitive to different assumptions and model inputs. Estimates of N(k) via alternative, ad hoc methods were 1.4 to > 30 times greater than the maximum clique estimate, suggesting that the alternative results may be upwardly biased. The maximum clique analysis was computationally intensive but could handle problems with < 1500 total pseudo-home ranges (points). Given present computational constraints, it is best suited for species that occur in clustered distributions (where the problem can be broken into several, smaller problems), or for species with large home ranges relative to grid scale where resampling the points to a coarser resolution can reduce the problem to manageable proportions.

  2. Flight behavior and performance of Rhodnius pallescens (Hemiptera: Reduviidae) on a tethered flight mill.

    PubMed

    Castro, Lauren A; Peterson, Jennifer K; Saldana, Azael; Perea, Milixa Y; Calzada, Jose E; Pineda, Vanessa; Dobson, Andrew P; Gottdenker, Nicole L

    2014-09-01

    ABSTRACT Flight dispersal of the triatomine bug species Rhodnius pallescens Barber, the principal vector of Chagas disease in Panama, is an important mechanism for spreading Trypanosoma cruzi, causative agent of Chagas disease. This study measures R. pallescens flight performance using a tethered flight mill both when uninfected, and when infected with T. cruzi or Trypanosoma rangeli. Forty-four out of the 48 (91.7%) insects initiated flight across all treatments, and trypanosome infection did not significantly impact flight initiation. Insects from all treatments flew a cumulative distance ranging from 0.5 to 5 km before fatiguing. The median cumulative distance flown before insect fatigue was higher in T. cruzi- and T. rangeli-infected insects than in control insects; however, this difference was not statistically significant. There was a positive relationship between parasite load ingested and time until flight initiation in T. rangeli-infected bugs, and T. rangeli- and T. cruzi-infected females flew significantly faster than males at different time points. These novel findings allow for a better understanding of R. pallescens dispersal ability and peridomestic management strategies for the prevention of Chagas disease in Panama.

  3. Use of a Lysine-Derived Urethane Surgical Adhesive as an Alternative to Progressive Tension Sutures in Abdominoplasty Patients: A Cohort Study.

    PubMed

    Spring, Michelle A

    2018-04-07

    Fluid accumulation is a common complication after abdominoplasty procedures, and is typically managed by the placement of post-surgical drains. Progressive tension sutures (PTS) have been shown to be an effective approach to reduce the dead space by point-wise mechanical fixation, allowing for drain-free procedures. Lysine-derived urethane surgical adhesive provides an alternative approach for mechanical fixation and reduction of dead space, and may reduce surgery time compared to PTS. This prospective, controlled, single center clinical study compared progressive tension suture wound closure technique without drains (control) to tissue adhesive wound closure technique without drains (test) during abdominoplasty surgery. The objective was to determine if lysine-derived urethane surgical adhesive is an effective alternative to PTS for drain-free abdominoplasty procedures. Patients undergoing abdominoplasty who met the established inclusion/exclusion criteria were consented and enrolled in the study. Ten PTS (control) cases were performed, followed immediately by ten tissue adhesive (test) cases. Drains were not used in any procedures. Key outcome measures included all major and minor post-surgical complications requiring any intervention, the time to place progressive tension sutures versus time for tissue adhesive application, and number of PTS attachments versus number of adhesive drops applied. Surgeries were completed over an 8-month period. No statistical differences were identified between the two groups with regard to age, BMI, dissection surface area or flap weight. No clinical seroma formation was observed in either group. In the control (PTS) group, two patients developed small areas of dermal closure suture abscess requiring removal of suture material. One control patient developed drainage and fat necrosis thought to be related to PTS above the incision and later required a scar revision. One tissue adhesive patient developed hypertrophic scars of both her breast reduction and abdominoplasty scars requiring additional treatment. The average time to place PTS in the control group was 10.7 minutes (range, 7-18 minutes) and the average number of sutures placed was 16.6 (range, 12-22 sutures). In the test group, the average time to place the tissue adhesive and hold pressure was 5.9 minutes (range 5.5-8.0 minutes). The average number of tissue adhesive drops applied was 69.6 (range: 63-78 drops). In the tissue adhesive group, both the reduction in time for flap adhesion and the increased number of adhesive points were statistically significant when compared to PTS. Lysine-derived urethane surgical adhesive was applied in less time than progressive tension sutures, even after accounting for holding pressure for 5 minutes. The tissue adhesive provided four times the number of attachment points compared to PTS, although the significance of this is not clear. There were no postoperative clinical seromas detected in either group and there were no major complications in either group. Based on these results, the use of lysine-derived urethane surgical adhesive was found to be a safe and effective alternative to progressive tension sutures to reduce seroma formation in drain-free abdominoplasty procedures.

  4. Recent acceleration of Thwaites Glacier

    NASA Technical Reports Server (NTRS)

    Ferrigno, J. G.

    1993-01-01

    The first velocity measurements for Thwaites Glacier were made by R. J. Allen in 1977. He compared features of Thwaites Glacier and Iceberg Tongue on aerial photography from 1947 and 1967 with 1972 Landsat images, and measured average annual displacements of 3.7 and 2.3 km/a. Using his photogrammetric experience and taking into consideration the lack of definable features and the poor control in the area, he estimated an average velocity of 2.0 to 2.9 km/a to be more accurate. In 1985, Lindstrom and Tyler also made velocity estimates for Thwaites Glacier. Using Landsat imagery from 1972 and 1983, their estimates of the velocities of 33 points ranged from 2.99 to 4.02 km/a, with an average of 3.6 km/a. The accuracy of their estimates is uncertain, however, because in the absence of fixed control points, they assumed that the velocities of icebergs in the fast ice were uniform. Using additional Landsat imagery in 1984 and 1990, accurate coregistration with the 1972 image was achieved based on fixed rock points. For the period 1972 to 1984, 25 points on the glacier surface ranged in average velocity from 2.47 to 2.76 km/a, with an overall average velocity of 2.62 +/- 0.02 km/a. For the period 1984 to 1990, 101 points ranged in velocity from 2.54 to 3.15 km/a, with an overall average of 2.84 km/a. During both time periods, the velocity pattern showed the same spatial relationship for three longitudinal paths. The 8-percent acceleration in a decade is significant. This recent acceleration may be associated with changes observed in this region since 1986. Fast ice melted and several icebergs calved from the base of the Iceberg Tongue and the terminus of Thwaites Glacier. However, as early as 1972, the Iceberg Tongue had very little contact with the glacier.

  5. Time delay and distance measurement

    NASA Technical Reports Server (NTRS)

    Abshire, James B. (Inventor); Sun, Xiaoli (Inventor)

    2011-01-01

    A method for measuring time delay and distance may include providing an electromagnetic radiation carrier frequency and modulating one or more of amplitude, phase, frequency, polarization, and pointing angle of the carrier frequency with a return to zero (RZ) pseudo random noise (PN) code. The RZ PN code may have a constant bit period and a pulse duration that is less than the bit period. A receiver may detect the electromagnetic radiation and calculate the scattering profile versus time (or range) by computing a cross correlation function between the recorded received signal and a three-state RZ PN code kernel in the receiver. The method also may be used for pulse delay time (i.e., PPM) communications.

  6. Mechanism of gas saturated oil viscosity anomaly near to phase transition point

    NASA Astrophysics Data System (ADS)

    Suleimanov, Baghir A.; Abbasov, Elkhan M.; Sisenbayeva, Marziya R.

    2017-01-01

    The article presents experimental studies of the phase behavior by the flash liberation test and of the viscosity of the live oil at different pressures. Unlike the typical studies at the pressure near the saturation pressure, the measurements were conducted at a relatively small pressure increment of 0.08-0.25 MPa. The viscosity anomaly was discovered experimentally near to the phase transition point in the range of the pressure levels P/Pb = 1-1.14 (Pb—bubble point pressure) and shows that it decreases about 70 times in comparison to the viscosity at the reservoir pressure. It was found that the bubble point pressure decreases significantly (up to 36%) with surfactant addition. Furthermore, the viscosity of the live oil at the surfactant concentration of 5 wt. % decreases almost 37 times in comparison to the viscosity at the reservoir pressure. The mechanism of observed effects was suggested based on the formation of the stable subcritical gas nuclei and associated slippage effect. The mechanism for the stabilization of the subcritical nuclei by the combined action of the surface and electrical forces, as well as the morphology of the formed nanobubbles, was considered. The model for determining the oil viscosity taking into account the slippage effect was suggested.

  7. Nonlinear digital signal processing in mental health: characterization of major depression using instantaneous entropy measures of heartbeat dynamics.

    PubMed

    Valenza, Gaetano; Garcia, Ronald G; Citi, Luca; Scilingo, Enzo P; Tomaz, Carlos A; Barbieri, Riccardo

    2015-01-01

    Nonlinear digital signal processing methods that address system complexity have provided useful computational tools for helping in the diagnosis and treatment of a wide range of pathologies. More specifically, nonlinear measures have been successful in characterizing patients with mental disorders such as Major Depression (MD). In this study, we propose the use of instantaneous measures of entropy, namely the inhomogeneous point-process approximate entropy (ipApEn) and the inhomogeneous point-process sample entropy (ipSampEn), to describe a novel characterization of MD patients undergoing affective elicitation. Because these measures are built within a nonlinear point-process model, they allow for the assessment of complexity in cardiovascular dynamics at each moment in time. Heartbeat dynamics were characterized from 48 healthy controls and 48 patients with MD while emotionally elicited through either neutral or arousing audiovisual stimuli. Experimental results coming from the arousing tasks show that ipApEn measures are able to instantaneously track heartbeat complexity as well as discern between healthy subjects and MD patients. Conversely, standard heart rate variability (HRV) analysis performed in both time and frequency domains did not show any statistical significance. We conclude that measures of entropy based on nonlinear point-process models might contribute to devising useful computational tools for care in mental health.

  8. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Laborda, Francisco; Medrano, Jesús; Castillo, Juan R.

    2004-06-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ.

  9. VizieR Online Data Catalog: ChaMP X-ray point source catalog (Kim+, 2007)

    NASA Astrophysics Data System (ADS)

    Kim, M.; Kim, D.-W.; Wilkes, B. J.; Green, P. J.; Kim, E.; Anderson, C. S.; Barkhouse, W. A.; Evans, N. R.; Ivezic, Z.; Karovska, M.; Kashyap, V. L.; Lee, M. G.; Maksym, P.; Mossman, A. E.; Silverman, J. D.; Tananbaum, H. D.

    2009-01-01

    We present the Chandra Multiwavelength Project (ChaMP) X-ray point source catalog with ~6800 X-ray sources detected in 149 Chandra observations covering ~10deg2. The full ChaMP catalog sample is 7 times larger than the initial published ChaMP catalog. The exposure time of the fields in our sample ranges from 0.9 to 124ks, corresponding to a deepest X-ray flux limit of f0.5-8.0=9x10-16ergs/cm2/s. The ChaMP X-ray data have been uniformly reduced and analyzed with ChaMP-specific pipelines and then carefully validated by visual inspection. The ChaMP catalog includes X-ray photometric data in eight different energy bands as well as X-ray spectral hardness ratios and colors. To best utilize the ChaMP catalog, we also present the source reliability, detection probability, and positional uncertainty. (10 data files).

  10. Terahertz time-domain spectroscopy of edible oils

    PubMed Central

    Valchev, Dimitar G.

    2017-01-01

    Chemical degradation of edible oils has been studied using conventional spectroscopic methods spanning the spectrum from ultraviolet to mid-IR. However, the possibility of morphological changes of oil molecules that can be detected at terahertz frequencies is beginning to receive some attention. Furthermore, the rapidly decreasing cost of this technology and its capability for convenient, in situ measurement of material properties, raises the possibility of monitoring oil during cooking and processing at production facilities, and more generally within the food industry. In this paper, we test the hypothesis that oil undergoes chemical and physical changes when heated above the smoke point, which can be detected in the 0.05–2 THz spectral range, measured using the conventional terahertz time-domain spectroscopy technique. The measurements demonstrate a null result in that there is no significant change in the spectra of terahertz optical parameters after heating above the smoke point for 5 min. PMID:28680681

  11. Terahertz time-domain spectroscopy of edible oils

    NASA Astrophysics Data System (ADS)

    Dinovitser, Alex; Valchev, Dimitar G.; Abbott, Derek

    2017-06-01

    Chemical degradation of edible oils has been studied using conventional spectroscopic methods spanning the spectrum from ultraviolet to mid-IR. However, the possibility of morphological changes of oil molecules that can be detected at terahertz frequencies is beginning to receive some attention. Furthermore, the rapidly decreasing cost of this technology and its capability for convenient, in situ measurement of material properties, raises the possibility of monitoring oil during cooking and processing at production facilities, and more generally within the food industry. In this paper, we test the hypothesis that oil undergoes chemical and physical changes when heated above the smoke point, which can be detected in the 0.05-2 THz spectral range, measured using the conventional terahertz time-domain spectroscopy technique. The measurements demonstrate a null result in that there is no significant change in the spectra of terahertz optical parameters after heating above the smoke point for 5 min.

  12. Entanglement negativity after a local quantum quench in conformal field theories

    NASA Astrophysics Data System (ADS)

    Wen, Xueda; Chang, Po-Yao; Ryu, Shinsei

    2015-08-01

    We study the time evolution of the entanglement negativity after a local quantum quench in (1 + 1)-dimensional conformal field theories (CFTs), which we introduce by suddenly joining two initially decoupled CFTs at their end points. We calculate the negativity evolution for both adjacent intervals and disjoint intervals explicitly. For two adjacent intervals, the entanglement negativity grows logarithmically in time right after the quench. After developing a plateau-like feature, the entanglement negativity drops to the ground-state value. For the case of two spatially separated intervals, a light-cone behavior is observed in the negativity evolution; in addition, a long-range entanglement, which is independent of the distance between two intervals, can be created. Our results agree with the heuristic picture that quasiparticles, which carry entanglement, are emitted from the joining point and propagate freely through the system. Our analytical results are confirmed by numerical calculations based on a critical harmonic chain.

  13. Terahertz time-domain spectroscopy of edible oils.

    PubMed

    Dinovitser, Alex; Valchev, Dimitar G; Abbott, Derek

    2017-06-01

    Chemical degradation of edible oils has been studied using conventional spectroscopic methods spanning the spectrum from ultraviolet to mid-IR. However, the possibility of morphological changes of oil molecules that can be detected at terahertz frequencies is beginning to receive some attention. Furthermore, the rapidly decreasing cost of this technology and its capability for convenient, in situ measurement of material properties, raises the possibility of monitoring oil during cooking and processing at production facilities, and more generally within the food industry. In this paper, we test the hypothesis that oil undergoes chemical and physical changes when heated above the smoke point, which can be detected in the 0.05-2 THz spectral range, measured using the conventional terahertz time-domain spectroscopy technique. The measurements demonstrate a null result in that there is no significant change in the spectra of terahertz optical parameters after heating above the smoke point for 5 min.

  14. Seismic precursory patterns before a cliff collapse and critical point phenomena

    USGS Publications Warehouse

    Amitrano, D.; Grasso, J.-R.; Senfaute, G.

    2005-01-01

    We analyse the statistical pattern of seismicity before a 1-2 103 m3 chalk cliff collapse on the Normandie ocean shore, Western France. We show that a power law acceleration of seismicity rate and energy in both 40 Hz-1.5 kHz and 2 Hz-10kHz frequency range, is defined on 3 orders of magnitude, within 2 hours from the collapse time. Simultaneously, the average size of the seismic events increases toward the time to failure. These in situ results are derived from the only station located within one rupture length distance from the rock fall rupture plane. They mimic the "critical point" like behavior recovered from physical and numerical experiments before brittle failures and tertiary creep failures. Our analysis of this first seismic monitoring data of a cliff collapse suggests that the thermodynamic phase transition models for failure may apply for cliff collapse. Copyright 2005 by the American Geophysical Union.

  15. Graz kHz SLR LIDAR: first results

    NASA Astrophysics Data System (ADS)

    Kirchner, Georg; Koidl, Franz; Kucharski, Daniel; Pachler, Walther; Seiss, Matthias; Leitgeb, Erich

    2009-05-01

    The Satellite Laser Ranging (SLR) Station Graz is measuring routinely distances to satellites with a 2 kHz laser, achieving an accuracy of 2-3 mm. Using this available equipment, we developed - and added as a byproduct - a kHz SLR LIDAR for the Graz station: Photons of each transmitted laser pulse are backscattered from clouds, atmospheric layers, aircraft vapor trails etc. An additional 10 cm diameter telescope - installed on our main telescope mount - and a Single- Photon Counting Module (SPCM) detect these photons. Using an ISA-Bus based FPGA card - developed in Graz for the kHz SLR operation - these detection times are stored with 100 ns resolution (15 m slots in distance). Event times of any number of laser shots can be accumulated in up to 4096 counters (according to > 60 km distance). The LIDAR distances are stored together with epoch time and telescope pointing information; any reflection point is therefore determined with 3D coordinates, with 15 m resolution in distance, and with the angular precision of the laser telescope pointing. First test results to clouds in full daylight conditions - accumulating up to several 100 laser shots per measurement - yielded high LIDAR data rates (> 100 points per second) and excellent detection of clouds (up to 10 km distance at the moment). Our ultimate goal is to operate the LIDAR automatically and in parallel with the standard SLR measurements, during day and night, collecting LIDAR data as a byproduct, and without any additional expenses.

  16. The Laser Ranging Experiment of the Lunar Reconnaissance Orbiter: Five Years of Operations and Data Analysis

    NASA Technical Reports Server (NTRS)

    Mao, Dandan; McGarry, Jan F.; Mazarico, Erwan; Neumann, Gregory A.; Sun, Xiaoli; Torrence, Mark H.; Zagwodzki, Thomas W.; Rowlands, David D.; Hoffman, Evan D.; Horvath, Julie E.; hide

    2016-01-01

    We describe the results of the Laser Ranging (LR) experiment carried out from June 2009 to September 2014 in order to make one-way time-of-flight measurements of laser pulses between Earth-based laser ranging stations and the Lunar Reconnaissance Orbiter (LRO) orbiting the Moon. Over 4,000 hours of successful LR data are obtained from 10 international ground stations. The 20-30 centimeter precision of the full-rate LR data is further improved to 5-10 centimeter after conversion into normal points. The main purpose of LR is to utilize the high accuracy normal point data to improve the quality of the LRO orbits, which are nomi- nally determined by the radiometric S-band tracking data. When independently used in the LRO precision orbit determination process with the high-resolution GRAIL (Gravity Recovery and Interior Laboratory) gravity model, LR data provide good orbit solutions, with an average difference of approximately 50 meters in total position, and approximately 20 centimeters in radial direction, compared to the definitive LRO trajectory. When used in combination with the S-band tracking data, LR data help to improve the orbit accuracy in the radial direction to approximately 15 centimeters. In order to obtain highly accurate LR range measurements for precise orbit determination results, it is critical to closely model the behavior of the clocks both at the ground stations and on the spacecraft. LR provides a unique data set to calibrate the spacecraft clock. The LRO spacecraft clock is characterized by the LR data to a timing knowledge of 0.015 milliseconds over the entire 5 years of LR operation. We here present both the engineering setup of the LR experiments and the detailed analysis results of the LR data.

  17. Isotopic metrics for structure, connectivity, and residence time in urban water supply systems

    NASA Astrophysics Data System (ADS)

    Bowen, Gabriel; Kennedy, Casey; Good, Stephen; Ehleringer, James

    2014-05-01

    Public water supply systems are the life-blood of urban areas, accessing, managing, and distributing water from an often complex array of sources to provide on-demand access to safe, potable water at the point-of-use. Water managers are faced with a wide range of potential threats, ranging from climate change to infrastructure failure to supply contamination. Information on the structure of supply and conveyance systems, connectivity within these systems, and links between the point-of-use and environmental water sources are thus critical to assessing the stability of water supplies and responding efficiently and effectively to water supply threats. We report datasets documenting stable hydrogen and oxygen isotope ratios of public supply water in cities of the United States across a range of scales. The data show a wide range of spatial and temporal variability that can be attributed to a combination of regional hydroclimate and water supply characteristics. Comparisons of public supply waters with model-based estimates of the isotopic composition of regional water sources suggests that major factors reflected in the tap water data include the degree of fragmentation of natural and man-made storage and conveyance systems, inter-basinal transfer of water, evaporative losses, and the total residence time of the natural and artificial systems being exploited. Because each of these factors contributes to determining the sustainability of water supply systems and their sensitivity to environmental disturbance, we propose a set of isotope-based metrics that can be used to efficiently assess and monitor the characteristics of public-supply systems in water security assessments and in support of management, planning, and outreach activities.

  18. Distributed optical fiber vibration sensor based on Sagnac interference in conjunction with OTDR.

    PubMed

    Pan, Chao; Liu, Xiaorui; Zhu, Hui; Shan, Xuekang; Sun, Xiaohan

    2017-08-21

    A real-time distributed optical fiber vibration sensing prototype based on the Sagnac interference in conjunction with the optical time domain reflectometry (OTDR) was developed. The sensing mechanism for single- and multi-points vibrations along the sensing fiber was analyzed theoretically and demonstrated experimentally. The experimental results show excellent agreement with the theoretical models. It is verified that single-point vibration induces a significantly abrupt and monotonous power change in the corresponding position of OTDR trace. As to multi-points vibrations, the detection of the following vibration is influenced by all previous ones. However, if the distance between the adjacent two vibrations is larger than half of the input optical pulse width, abrupt power changes induced by them are separate and still monotonous. A time-shifting differential module was developed and carried out to convert vibration-induced power changes to pulses. Consequently, vibrations can be located accurately by measuring peak or valley positions of the vibration-induced pulses. It is demonstrated that when the width and peak power of input optical pulse are set to 1 μs and 35 mW, respectively, the position error is less than ± 0.5 m in a sensing range of more than 16 km, with the spatial resolution of ~110 m.

  19. A validated methodology for determination of laboratory instrument computer interface efficacy

    NASA Astrophysics Data System (ADS)

    1984-12-01

    This report is intended to provide a methodology for determining when, and for which instruments, direct interfacing of laboratory instrument and laboratory computers is beneficial. This methodology has been developed to assist the Tri-Service Medical Information Systems Program Office in making future decisions regarding laboratory instrument interfaces. We have calculated the time savings required to reach a break-even point for a range of instrument interface prices and corresponding average annual costs. The break-even analyses used empirical data to estimate the number of data points run per day that are required to meet the break-even point. The results indicate, for example, that at a purchase price of $3,000, an instrument interface will be cost-effective if the instrument is utilized for at least 154 data points per day if operated in the continuous mode, or 216 points per day if operated in the discrete mode. Although this model can help to ensure that instrument interfaces are cost effective, additional information should be considered in making the interface decisions. A reduction in results transcription errors may be a major benefit of instrument interfacing.

  20. A CPU benchmark for protein crystallographic refinement.

    PubMed

    Bourne, P E; Hendrickson, W A

    1990-01-01

    The CPU time required to complete a cycle of restrained least-squares refinement of a protein structure from X-ray crystallographic data using the FORTRAN codes PROTIN and PROLSQ are reported for 48 different processors, ranging from single-user workstations to supercomputers. Sequential, vector, VLIW, multiprocessor, and RISC hardware architectures are compared using both a small and a large protein structure. Representative compile times for each hardware type are also given, and the improvement in run-time when coding for a specific hardware architecture considered. The benchmarks involve scalar integer and vector floating point arithmetic and are representative of the calculations performed in many scientific disciplines.

  1. Surgery for Retrocalcaneal Bursitis: A Tendon-splitting versus a Lateral Approach

    PubMed Central

    Anderson, John A.; Suero, Eduardo; O’Loughlin, Padhraig F.

    2008-01-01

    For patients with refractory retrocalcaneal bursitis (Haglund’s syndrome), the most effective surgical approach has not been defined. We asked whether patients undergoing the tendon-splitting approach and the lateral approach would have comparably effective relief of pain for both types of calcaneal ostectomies. We retrospectively reviewed 30 patients (31 feet) who underwent the tendon-splitting approach and compared their results with 32 previous patients (35 feet) who had a lateral incision. Minimum followup was 12 months (mean, 16 months; range, 12–23 months) for the tendon-splitting group and 15 months (mean, 51 months; range, 15–109 months) for the lateral group. The mean American Orthopaedic Foot and Ankle Society score improved from 43 points preoperatively to 81 points (range, 8–100 points) postoperatively in the tendon-splitting group and from 54 points to 86 points (range, 55–100 points) in the lateral group. The mean physical component score of the Short Form-36, version 2, at followup was 52 (range, 22–61) in the tendon-splitting group and 49 (range, 34–63) in the lateral group. The median return to normal function was 4.1 months (range, 3–13 months) in the tendon-splitting group and 6.4 months (range, 4–20 months) in the lateral group. Both approaches to calcaneal ostectomy provided symptomatic pain relief. However, patients in the tendon-splitting group returned to normal function quicker than patients in the lateral group. Level of Evidence: Level III, retrospective comparative study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18465183

  2. Testing photogrammetry-based techniques for three-dimensional surface documentation in forensic pathology.

    PubMed

    Urbanová, Petra; Hejna, Petr; Jurda, Mikoláš

    2015-05-01

    Three-dimensional surface technologies particularly close range photogrammetry and optical surface scanning have recently advanced into affordable, flexible and accurate techniques. Forensic postmortem investigation as performed on a daily basis, however, has not yet fully benefited from their potentials. In the present paper, we tested two approaches to 3D external body documentation - digital camera-based photogrammetry combined with commercial Agisoft PhotoScan(®) software and stereophotogrammetry-based Vectra H1(®), a portable handheld surface scanner. In order to conduct the study three human subjects were selected, a living person, a 25-year-old female, and two forensic cases admitted for postmortem examination at the Department of Forensic Medicine, Hradec Králové, Czech Republic (both 63-year-old males), one dead to traumatic, self-inflicted, injuries (suicide by hanging), the other diagnosed with the heart failure. All three cases were photographed in 360° manner with a Nikon 7000 digital camera and simultaneously documented with the handheld scanner. In addition to having recorded the pre-autopsy phase of the forensic cases, both techniques were employed in various stages of autopsy. The sets of collected digital images (approximately 100 per case) were further processed to generate point clouds and 3D meshes. Final 3D models (a pair per individual) were counted for numbers of points and polygons, then assessed visually and compared quantitatively using ICP alignment algorithm and a cloud point comparison technique based on closest point to point distances. Both techniques were proven to be easy to handle and equally laborious. While collecting the images at autopsy took around 20min, the post-processing was much more time-demanding and required up to 10h of computation time. Moreover, for the full-body scanning the post-processing of the handheld scanner required rather time-consuming manual image alignment. In all instances the applied approaches produced high-resolution photorealistic, real sized or easy to calibrate 3D surface models. Both methods equally failed when the scanned body surface was covered with body hair or reflective moist areas. Still, it can be concluded that single camera close range photogrammetry and optical surface scanning using Vectra H1 scanner represent relatively low-cost solutions which were shown to be beneficial for postmortem body documentation in forensic pathology. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Automatic techniques for 3D reconstruction of critical workplace body postures from range imaging data

    NASA Astrophysics Data System (ADS)

    Westfeld, Patrick; Maas, Hans-Gerd; Bringmann, Oliver; Gröllich, Daniel; Schmauder, Martin

    2013-11-01

    The paper shows techniques for the determination of structured motion parameters from range camera image sequences. The core contribution of the work presented here is the development of an integrated least squares 3D tracking approach based on amplitude and range image sequences to calculate dense 3D motion vector fields. Geometric primitives of a human body model are fitted to time series of range camera point clouds using these vector fields as additional information. Body poses and motion information for individual body parts are derived from the model fit. On the basis of these pose and motion parameters, critical body postures are detected. The primary aim of the study is to automate ergonomic studies for risk assessments regulated by law, identifying harmful movements and awkward body postures in a workplace.

  4. Geodetic positioning using a global positioning system of satellites

    NASA Technical Reports Server (NTRS)

    Fell, P. J.

    1980-01-01

    Geodetic positioning using range, integrated Doppler, and interferometric observations from a constellation of twenty-four Global Positioning System satellites is analyzed. A summary of the proposals for geodetic positioning and baseline determination is given which includes a description of measurement techniques and comments on rank deficiency and error sources. An analysis of variance comparison of range, Doppler, and interferometric time delay to determine their relative geometric strength for baseline determination is included. An analytic examination to the effect of a priori constraints on positioning using simultaneous observations from two stations is presented. Dynamic point positioning and baseline determination using range and Doppler is examined in detail. Models for the error sources influencing dynamic positioning are developed. Included is a discussion of atomic clock stability, and range and Doppler observation error statistics based on random correlated atomic clock error are derived.

  5. Terrain shape estimation from optical flow, using Kalman filtering

    NASA Astrophysics Data System (ADS)

    Hoff, William A.; Sklair, Cheryl W.

    1990-01-01

    As one moves through a static environment, the visual world as projected on the retina seems to flow past. This apparent motion, called optical flow, can be an important source of depth perception for autonomous robots. An important application is in planetary exploration -the landing vehicle must find a safe landing site in rugged terrain, and an autonomous rover must be able to navigate safely through this terrain. In this paper, we describe a solution to this problem. Image edge points are tracked between frames of a motion sequence, and the range to the points is calculated from the displacement of the edge points and the known motion of the camera. Kalman filtering is used to incrementally improve the range estimates to those points, and provide an estimate of the uncertainty in each range. Errors in camera motion and image point measurement can also be modelled with Kalman filtering. A surface is then interpolated to these points, providing a complete map from which hazards such as steeply sloping areas can be detected. Using the method of extended Kalman filtering, our approach allows arbitrary camera motion. Preliminary results of an implementation are presented, and show that the resulting range accuracy is on the order of 1-2% of the range.

  6. Analysis of Land Subsidence Monitoring in Mining Area with Time-Series Insar Technology

    NASA Astrophysics Data System (ADS)

    Sun, N.; Wang, Y. J.

    2018-04-01

    Time-series InSAR technology has become a popular land subsidence monitoring method in recent years, because of its advantages such as high accuracy, wide area, low expenditure, intensive monitoring points and free from accessibility restrictions. In this paper, we applied two kinds of satellite data, ALOS PALSAR and RADARSAT-2, to get the subsidence monitoring results of the study area in two time periods by time-series InSAR technology. By analyzing the deformation range, rate and amount, the time-series analysis of land subsidence in mining area was realized. The results show that InSAR technology could be used to monitor land subsidence in large area and meet the demand of subsidence monitoring in mining area.

  7. First Neutrino Point-Source Results from the 22 String Icecube Detector

    NASA Astrophysics Data System (ADS)

    Abbasi, R.; Abdou, Y.; Ackermann, M.; Adams, J.; Aguilar, J.; Ahlers, M.; Andeen, K.; Auffenberg, J.; Bai, X.; Baker, M.; Barwick, S. W.; Bay, R.; Bazo Alba, J. L.; Beattie, K.; Beatty, J. J.; Bechet, S.; Becker, J. K.; Becker, K.-H.; Benabderrahmane, M. L.; Berdermann, J.; Berghaus, P.; Berley, D.; Bernardini, E.; Bertrand, D.; Besson, D. Z.; Bissok, M.; Blaufuss, E.; Boersma, D. J.; Bohm, C.; Bolmont, J.; Böser, S.; Botner, O.; Bradley, L.; Braun, J.; Breder, D.; Castermans, T.; Chirkin, D.; Christy, B.; Clem, J.; Cohen, S.; Cowen, D. F.; D'Agostino, M. V.; Danninger, M.; Day, C. T.; De Clercq, C.; Demirörs, L.; Depaepe, O.; Descamps, F.; Desiati, P.; de Vries-Uiterweerd, G.; De Young, T.; Diaz-Velez, J. C.; Dreyer, J.; Dumm, J. P.; Duvoort, M. R.; Edwards, W. R.; Ehrlich, R.; Eisch, J.; Ellsworth, R. W.; Engdegård, O.; Euler, S.; Evenson, P. A.; Fadiran, O.; Fazely, A. R.; Feusels, T.; Filimonov, K.; Finley, C.; Foerster, M. M.; Fox, B. D.; Franckowiak, A.; Franke, R.; Gaisser, T. K.; Gallagher, J.; Ganugapati, R.; Gerhardt, L.; Gladstone, L.; Goldschmidt, A.; Goodman, J. A.; Gozzini, R.; Grant, D.; Griesel, T.; Groß, A.; Grullon, S.; Gunasingha, R. M.; Gurtner, M.; Ha, C.; Hallgren, A.; Halzen, F.; Han, K.; Hanson, K.; Hasegawa, Y.; Heise, J.; Helbing, K.; Herquet, P.; Hickford, S.; Hill, G. C.; Hoffman, K. D.; Hoshina, K.; Hubert, D.; Huelsnitz, W.; Hülß, J.-P.; Hulth, P. O.; Hultqvist, K.; Hussain, S.; Imlay, R. L.; Inaba, M.; Ishihara, A.; Jacobsen, J.; Japaridze, G. S.; Johansson, H.; Joseph, J. M.; Kampert, K.-H.; Kappes, A.; Karg, T.; Karle, A.; Kelley, J. L.; Kenny, P.; Kiryluk, J.; Kislat, F.; Klein, S. R.; Klepser, S.; Knops, S.; Kohnen, G.; Kolanoski, H.; Köpke, L.; Kowalski, M.; Kowarik, T.; Krasberg, M.; Kuehn, K.; Kuwabara, T.; Labare, M.; Lafebre, S.; Laihem, K.; Landsman, H.; Lauer, R.; Leich, H.; Lennarz, D.; Lucke, A.; Lundberg, J.; Lünemann, J.; Madsen, J.; Majumdar, P.; Maruyama, R.; Mase, K.; Matis, H. S.; McParland, C. P.; Meagher, K.; Merck, M.; Mészáros, P.; Middell, E.; Milke, N.; Miyamoto, H.; Mohr, A.; Montaruli, T.; Morse, R.; Movit, S. M.; Münich, K.; Nahnhauer, R.; Nam, J. W.; Nießen, P.; Nygren, D. R.; Odrowski, S.; Olivas, A.; Olivo, M.; Ono, M.; Panknin, S.; Patton, S.; Pérez de los Heros, C.; Petrovic, J.; Piegsa, A.; Pieloth, D.; Pohl, A. C.; Porrata, R.; Potthoff, N.; Price, P. B.; Prikockis, M.; Przybylski, G. T.; Rawlins, K.; Redl, P.; Resconi, E.; Rhode, W.; Ribordy, M.; Rizzo, A.; Rodrigues, J. P.; Roth, P.; Rothmaier, F.; Rott, C.; Roucelle, C.; Rutledge, D.; Ryckbosch, D.; Sander, H.-G.; Sarkar, S.; Satalecka, K.; Schlenstedt, S.; Schmidt, T.; Schneider, D.; Schukraft, A.; Schulz, O.; Schunck, M.; Seckel, D.; Semburg, B.; Seo, S. H.; Sestayo, Y.; Seunarine, S.; Silvestri, A.; Slipak, A.; Spiczak, G. M.; Spiering, C.; Stamatikos, M.; Stanev, T.; Stephens, G.; Stezelberger, T.; Stokstad, R. G.; Stoufer, M. C.; Stoyanov, S.; Strahler, E. A.; Straszheim, T.; Sulanke, K.-H.; Sullivan, G. W.; Swillens, Q.; Taboada, I.; Tarasova, O.; Tepe, A.; Ter-Antonyan, S.; Terranova, C.; Tilav, S.; Tluczykont, M.; Toale, P. A.; Tosi, D.; Turčan, D.; van Eijndhoven, N.; Vandenbroucke, J.; Van Overloop, A.; Voigt, B.; Walck, C.; Waldenmaier, T.; Walter, M.; Wendt, C.; Westerhoff, S.; Whitehorn, N.; Wiebusch, C. H.; Wiedemann, A.; Wikström, G.; Williams, D. R.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Xu, X. W.; Yodh, G.; Ice Cube Collaboration

    2009-08-01

    We present new results of searches for neutrino point sources in the northern sky, using data recorded in 2007-2008 with 22 strings of the IceCube detector (approximately one-fourth of the planned total) and 275.7 days of live time. The final sample of 5114 neutrino candidate events agrees well with the expected background of atmospheric muon neutrinos and a small component of atmospheric muons. No evidence of a point source is found, with the most significant excess of events in the sky at 2.2σ after accounting for all trials. The average upper limit over the northern sky for point sources of muon-neutrinos with E -2 spectrum is E^{2} Φ_{ν_{μ}} < 1.4 × 10^{-11} TeV cm^{-2} s^{-1}, in the energy range from 3 TeV to 3 PeV, improving the previous best average upper limit by the AMANDA-II detector by a factor of 2.

  8. Sampled control stability of the ESA instrument pointing system

    NASA Astrophysics Data System (ADS)

    Thieme, G.; Rogers, P.; Sciacovelli, D.

    Stability analysis and simulation results are presented for the ESA Instrument Pointing System (IPS) that is to be used in Spacelab's second launch. Of the two IPS plant dynamic models used in the ESA and NASA activities, one is based on six interconnected rigid bodies that represent the IPS and plant dynamic models used in the ESA and NASA activities, one is based on six interconnected rigid bodies that represent the IPS and its payload, while the other follows the NASA practice of defining an IPS-Spacelab 2 plant configuration through a structural finite element model, which is then used to generate modal data for various pointing directions. In both cases, the IPS dynamic plant model is truncated, then discretized at the sampling frequency and interfaces to a PID-based control law. A stability analysis has been carried out in discrete domain for various instrument pointing directions, taking into account suitable parameter variation ranges. A number of time simulations are presented.

  9. Effect of spinal needle characteristics on measurement of spinal canal opening pressure.

    PubMed

    Bellamkonda, Venkatesh R; Wright, Thomas C; Lohse, Christine M; Keaveny, Virginia R; Funk, Eric C; Olson, Michael D; Laack, Torrey A

    2017-05-01

    A wide variety of spinal needles are used in clinical practice. Little is currently known regarding the impact of needle length, gauge, and tip type on the needle's ability to measure spinal canal opening pressure. This study aimed to investigate the relationship between these factors and the opening-pressure measurement or time to obtain an opening pressure. Thirteen distinct spinal needles, chosen to isolate the effects of length, gauge, and needle-point type, were prospectively tested on a lumbar puncture simulator. The key outcomes were the opening-pressure measurement and the time required to obtain that measure. Pressures were recorded at 10-s intervals until 3 consecutive, identical readings were observed. Time to measure opening pressure increased with increasing spinal needle length, increasing gauge, and the Quincke-type (cutting) point (P<0.001 for all). The time to measurement ranged from 30s to 530s, yet all needle types were able to obtain a consistent opening pressure measure. Although opening pressure estimates are unlikely to vary markedly by needle type, the time required to obtain the measurement increased with increasing needle length and gauge and with Quincke-type needles. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Predictable communities of soil bacteria in relation to nutrient concentration and successional stage in a laboratory culture experiment.

    PubMed

    Song, Woojin; Kim, Mincheol; Tripathi, Binu M; Kim, Hyoki; Adams, Jonathan M

    2016-06-01

    It is difficult to understand the processes that structure immensely complex bacterial communities in the soil environment, necessitating a simplifying experimental approach. Here, we set up a microcosm culturing experiment with soil bacteria, at a range of nutrient concentrations, and compared these over time to understand the relationship between soil bacterial community structure and time/nutrient concentration. DNA from each replicate was analysed using HiSeq2000 Illumina sequencing of the 16S rRNA gene. We found that each nutrient treatment, and each time point during the experiment, produces characteristic bacterial communities that occur predictably between replicates. It is clear that within the context of this experiment, many soil bacteria have distinct niches from one another, in terms of both nutrient concentration, and successional time point since a resource first became available. This fine niche differentiation may in part help to explain the coexistence of a diversity of bacteria in soils. In this experiment, we show that the unimodal relationship between nutrient concentration/time and species diversity often reported in communities of larger organisms is also evident in microbial communities. © 2015 Society for Applied Microbiology and John Wiley & Sons Ltd.

  11. Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

    PubMed

    Yoon, Jai-Woong; Sawant, Amit; Suh, Yelin; Cho, Byung-Chul; Suh, Tae-Suk; Keall, Paul

    2011-07-01

    In dynamic multileaf collimator (MLC) motion tracking with complex intensity-modulated radiation therapy (IMRT) fields, target motion perpendicular to the MLC leaf travel direction can cause beam holds, which increase beam delivery time by up to a factor of 4. As a means to balance delivery efficiency and accuracy, a moving average algorithm was incorporated into a dynamic MLC motion tracking system (i.e., moving average tracking) to account for target motion perpendicular to the MLC leaf travel direction. The experimental investigation of the moving average algorithm compared with real-time tracking and no compensation beam delivery is described. The properties of the moving average algorithm were measured and compared with those of real-time tracking (dynamic MLC motion tracking accounting for both target motion parallel and perpendicular to the leaf travel direction) and no compensation beam delivery. The algorithm was investigated using a synthetic motion trace with a baseline drift and four patient-measured 3D tumor motion traces representing regular and irregular motions with varying baseline drifts. Each motion trace was reproduced by a moving platform. The delivery efficiency, geometric accuracy, and dosimetric accuracy were evaluated for conformal, step-and-shoot IMRT, and dynamic sliding window IMRT treatment plans using the synthetic and patient motion traces. The dosimetric accuracy was quantified via a tgamma-test with a 3%/3 mm criterion. The delivery efficiency ranged from 89 to 100% for moving average tracking, 26%-100% for real-time tracking, and 100% (by definition) for no compensation. The root-mean-square geometric error ranged from 3.2 to 4.0 mm for moving average tracking, 0.7-1.1 mm for real-time tracking, and 3.7-7.2 mm for no compensation. The percentage of dosimetric points failing the gamma-test ranged from 4 to 30% for moving average tracking, 0%-23% for real-time tracking, and 10%-47% for no compensation. The delivery efficiency of moving average tracking was up to four times higher than that of real-time tracking and approached the efficiency of no compensation for all cases. The geometric accuracy and dosimetric accuracy of the moving average algorithm was between real-time tracking and no compensation, approximately half the percentage of dosimetric points failing the gamma-test compared with no compensation.

  12. Time domain SAR raw data simulation using CST and image focusing of 3D objects

    NASA Astrophysics Data System (ADS)

    Saeed, Adnan; Hellwich, Olaf

    2017-10-01

    This paper presents the use of a general purpose electromagnetic simulator, CST, to simulate realistic synthetic aperture radar (SAR) raw data of three-dimensional objects. Raw data is later focused in MATLAB using range-doppler algorithm. Within CST Microwave Studio a replica of TerraSAR-X chirp signal is incident upon a modeled Corner Reflector (CR) whose design and material properties are identical to that of the real one. Defining mesh and other appropriate settings reflected wave is measured at several distant points within a line parallel to the viewing direction. This is analogous to an array antenna and is synthesized to create a long aperture for SAR processing. The time domain solver in CST is based on the solution of differential form of Maxwells equations. Exported data from CST is arranged into a 2-d matrix of axis range and azimuth. Hilbert transform is applied to convert the real signal to complex data with phase information. Range compression, range cell migration correction (RCMC), and azimuth compression are applied in time domain to obtain the final SAR image. This simulation can provide valuable information to clarify which real world objects cause images suitable for high accuracy identification in the SAR images.

  13. Statistical properties of solar Hα flare activity

    NASA Astrophysics Data System (ADS)

    Deng, Linhua; Zhang, Xiaojuan; An, Jianmei; Cai, Yunfang

    2017-12-01

    Magnetic field structures on the solar atmosphere are not symmetric distribution in the northern and southern hemispheres, which is an important aspect of quasi-cyclical evolution of magnetic activity indicators that are related to solar dynamo theories. Three standard analysis techniques are applied to analyze the hemispheric coupling (north-south asymmetry and phase asynchrony) of monthly averaged values of solar Hα flare activity over the past 49 years (from 1966 January to 2014 December). The prominent results are as follows: (1) from a global point of view, solar Hα flare activity on both hemispheres are strongly correlated with each other, but the northern hemisphere precedes the southern one with a phase shift of 7 months; (2) the long-range persistence indeed exists in solar Hα flare activity, but the dynamical complexities in the two hemispheres are not identical; (3) the prominent periodicities of Hα flare activity are 17 years full-disk activity cycle and 11 years Schwabe solar cycle, but the short- and mid-term periodicities cannot determined by monthly time series; (4) by comparing the non-parametric rescaling behavior on a point-by-point basis, the hemispheric asynchrony of solar Hα flare activity are estimated to be ranging from several months to tens of months with an average value of 8.7 months. The analysis results could promote our knowledge on the long-range persistence, the quasi-periodic variation, and the hemispheric asynchrony of solar Hα flare activity on both hemispheres, and possibly provide valuable information for the hemispheric interrelation of solar magnetic activity.

  14. Ultrafast and Doppler-free femtosecondoptical ranging based on dispersivefrequency-modulated interferometry.

    PubMed

    Xia, Haiyun; Zhang, Chunxi

    2010-03-01

    An ultrafast and Doppler-free optical ranging system based on dispersive frequency-modulated interferometry is demonstrated. The principle is similar to the conventional frequency-modulated continuous-wave interferometry where the range information is derived from the beat frequency between the object signal and the reference signal. However, a passive and static frequency scanning is performed based on the chromatic dispersion of a transform-limited femtosecond pulse in the time domain. We point out that the unbalanced dispersion introduced in the Mach-Zehnder interferometer can be optimized to eliminate the frequency chirp in the temporal interferograms pertaining to the third order dispersion of the all-fiber system, if the dynamic range being considered is small. Some negative factors, such as the polarization instability of the femtosecond pulse, the power fluctuation of the optical signal and the nonuniform gain spectrum of the erbium-doped fiber amplifier lead to an obvious envelope deformation of the temporal interferograms from the Gaussian shape. Thus a new data processing method is proposed to guarantee the range resolution. In the experiment, the vibration of a speaker is measured. A range resolution of 1.59 microm is achieved with an exposure time of 394 fs at a sampling rate of 48.6 MHz.

  15. Delay Analysis of GTS Bridging between IEEE 802.15.4 and IEEE 802.11 Networks for Healthcare Applications

    PubMed Central

    Mišić, Jelena; (Sherman) Shen, Xuemin

    2009-01-01

    We consider interconnection of IEEE 802.15.4 beacon-enabled network cluster with IEEE 802.11b network. This scenario is important in healthcare applications where IEEE 802.15.4 nodes comprise patient's body area network (BAN) and are involved in sensing some health-related data. BAN nodes have very short communication range in order to avoid harming patient's health and save energy. Sensed data needs to be transmitted to an access point in the ward room using wireless technology with higher transmission range and rate such as IEEE 802.11b. We model the interconnected network where IEEE 802.15.4-based BAN operates in guaranteed time slot (GTS) mode, and IEEE 802.11b part of the bridge conveys GTS superframe to the 802.11b access point. We then analyze the network delays. Performance analysis is performed using EKG traffic from continuous telemetry, and we discuss the delays of communication due the increasing number of patients. PMID:19107184

  16. Delay Analysis of GTS Bridging between IEEE 802.15.4 and IEEE 802.11 Networks for Healthcare Applications.

    PubMed

    Misić, Jelena; Sherman Shen, Xuemin

    2009-01-01

    We consider interconnection of IEEE 802.15.4 beacon-enabled network cluster with IEEE 802.11b network. This scenario is important in healthcare applications where IEEE 802.15.4 nodes comprise patient's body area network (BAN) and are involved in sensing some health-related data. BAN nodes have very short communication range in order to avoid harming patient's health and save energy. Sensed data needs to be transmitted to an access point in the ward room using wireless technology with higher transmission range and rate such as IEEE 802.11b. We model the interconnected network where IEEE 802.15.4-based BAN operates in guaranteed time slot (GTS) mode, and IEEE 802.11b part of the bridge conveys GTS superframe to the 802.11b access point. We then analyze the network delays. Performance analysis is performed using EKG traffic from continuous telemetry, and we discuss the delays of communication due the increasing number of patients.

  17. Synthesis of atmospheric turbulence point spread functions by sparse and redundant representations

    NASA Astrophysics Data System (ADS)

    Hunt, Bobby R.; Iler, Amber L.; Bailey, Christopher A.; Rucci, Michael A.

    2018-02-01

    Atmospheric turbulence is a fundamental problem in imaging through long slant ranges, horizontal-range paths, or uplooking astronomical cases through the atmosphere. An essential characterization of atmospheric turbulence is the point spread function (PSF). Turbulence images can be simulated to study basic questions, such as image quality and image restoration, by synthesizing PSFs of desired properties. In this paper, we report on a method to synthesize PSFs of atmospheric turbulence. The method uses recent developments in sparse and redundant representations. From a training set of measured atmospheric PSFs, we construct a dictionary of "basis functions" that characterize the atmospheric turbulence PSFs. A PSF can be synthesized from this dictionary by a properly weighted combination of dictionary elements. We disclose an algorithm to synthesize PSFs from the dictionary. The algorithm can synthesize PSFs in three orders of magnitude less computing time than conventional wave optics propagation methods. The resulting PSFs are also shown to be statistically representative of the turbulence conditions that were used to construct the dictionary.

  18. Linking Childhood Maltreatment with Girls’ Internalizing Symptoms: Early Puberty as a Tipping Point

    PubMed Central

    Mendle, Jane; Leve, Leslie D.; Van Ryzin, Mark; Natsuaki, Misaki N.

    2013-01-01

    Early pubertal timing in girls is one of the most frequently replicated antecedents of adolescent emotional distress. Yet understanding the impact of pubertal timing in psychosocial development has presented something of a conundrum for developmentalists, as earlier physical maturation may often be preceded by a range of early adversities and life stressors. The present paper disentangles these associations by investigating childhood maltreatment, adolescent internalizing symptoms, and perceived pubertal timing in girls who were residing in foster care at study entry (N = 100, M = 11.54 years old at Time 1). Girls were assessed at two time points two years apart. There were no significant direct effects of maltreatment on internalizing symptoms; rather, childhood sexual abuse predicted earlier perceived pubertal development at study onset which, in turn, was associated with higher levels of internalizing symptomatology. These higher levels of internalizing symptoms persisted over the two years of the study. This distinctive role for early pubertal timing – even within a sample subject to stressors and risks which far exceed the developmental norm – confirms the unique salience of pubertal timing in emotional adjustment, and suggests that the heightened sexual circumstances of puberty may be especially disturbing for girls whose lives have already been traumatically disrupted by inappropriate and unwanted sexual experiences. PMID:25419091

  19. Estimated drawdowns in the Floridan aquifer due to increased withdrawals, Duval County, Florida

    USGS Publications Warehouse

    Franks, Bernard J.; Phelps, G.G.

    1979-01-01

    Hydrologic investigations of the Floridan aquifer in Duval County, Florida, have shown that an appropriate simplified model of the aquifer system consists of a series of sub aquifers separated by semipermeable beds. Data from more than 20 aquifer tests were reanalyzed by the Hantush modified method, which takes into account leakance from all confining units. Transmissivity values range from 20,000 to 240,000 square feet per day. Leakance was estimated to be 2.5x10 to the minus 6th power and 3.3x10 to the minus 5th power per day for the upper and lower confining units, respectively. Families of steady-state distance-drawdown curves were constructed for three representative transmissivity values based on hypothetical withdrawals from a point source ranging from 5 to 50 million gallons per day. Transient effects were not considered because the system reaches steady-state conditions within the time ranges considered. Drawdown at any point can be estimated by summing the effects of any hypothetical configuration of pumping centers. The accuracy of the parameters was checked by comparing calculated drawdowns in selected observation wells to measured water-level declines. (Woodard-USGS)

  20. Cloud Computing with Context Cameras

    NASA Astrophysics Data System (ADS)

    Pickles, A. J.; Rosing, W. E.

    2016-05-01

    We summarize methods and plans to monitor and calibrate photometric observations with our autonomous, robotic network of 2m, 1m and 40cm telescopes. These are sited globally to optimize our ability to observe time-variable sources. Wide field "context" cameras are aligned with our network telescopes and cycle every ˜2 minutes through BVr'i'z' filters, spanning our optical range. We measure instantaneous zero-point offsets and transparency (throughput) against calibrators in the 5-12m range from the all-sky Tycho2 catalog, and periodically against primary standards. Similar measurements are made for all our science images, with typical fields of view of ˜0.5 degrees. These are matched against Landolt, Stetson and Sloan standards, and against calibrators in the 10-17m range from the all-sky APASS catalog. Such measurements provide pretty good instantaneous flux calibration, often to better than 5%, even in cloudy conditions. Zero-point and transparency measurements can be used to characterize, monitor and inter-compare sites and equipment. When accurate calibrations of Target against Standard fields are required, monitoring measurements can be used to select truly photometric periods when accurate calibrations can be automatically scheduled and performed.

  1. High-powered microwave ablation with a small-gauge, gas-cooled antenna: initial ex vivo and in vivo results.

    PubMed

    Lubner, Meghan G; Hinshaw, J Louis; Andreano, Anita; Sampson, Lisa; Lee, Fred T; Brace, Christopher L

    2012-03-01

    To evaluate the performance of a gas-cooled, high-powered microwave system. Investigators performed 54 ablations in ex vivo bovine livers using three devices-a single 17-gauge cooled radiofrequency(RF) electrode; a cluster RF electrode; and a single 17-gauge, gas-cooled microwave (MW) antenna-at three time points (n = 6 at 4 minutes, 12 minutes, and 16 minutes). RF power was applied using impedance-based pulsing with maximum 200 W generator output. MW power of 135 W at 2.45 GHz was delivered continuously. An approved in vivo study was performed using 13 domestic pigs. Hepatic ablations were performed using single applicators and the above-mentioned MW and RF generator systems at treatment times of 2 minutes (n = 7 MW, n = 6 RF), 5 minutes (n = 23 MW, n = 8 RF), 7 minutes (n = 11 MW, n = 6 RF), and 10 minutes (n = 7 MW, n = 9 RF). Mean transverse diameter and length of the ablation zones were compared using analysis of variance (ANOVA) with post-hoc t tests and Wilcoxon rank-sum tests. Single ex vivo MW ablations were larger than single RF ablations at all time points (MW mean diameter range 3.5-4.8 cm 4-16 minutes; RF mean diameter range 2.6-3.1 cm 4-16 minutes) (P < .05). There was no difference in mean diameter between cluster RF and MW ablations (RF 3.3-4.4 cm 4-16 minutes; P = .4-.9). In vivo lesion diameters for MW (and RF) were as follows: 2.6 cm ± 0.72 (RF 1.5 cm ± 0.14), 3.6 cm ± 0.89 (RF 2.0 cm ± 0.4), 3.4 cm ± 0.87 (RF 1.8 cm ± 0.23), and 3.8 cm ± 0.74 (RF 2.1 cm ± 0.3) at 2 minutes, 5 minutes, 7 minutes, and 10 minutes (P < .05 all time points). Gas-cooled, high-powered MW ablation allows the generation of large ablation zones in short times. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  2. An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization

    NASA Astrophysics Data System (ADS)

    Benyon, R.; Böse, N.; Mitter, H.; Mutter, D.; Vicente, T.

    2012-09-01

    Precision optical dew-point hygrometers are the most commonly used transfer standards for the comparison of dew-point temperature realizations at National Metrology Institutes (NMIs) and for disseminating traceability to calibration laboratories. These instruments have been shown to be highly reproducible when properly used. In order to obtain the best performance, the resistance of the platinum resistance thermometer (PRT) embedded in the mirror is usually measured with an external, traceable resistance bridge or digital multimeter. The relation between the conventional calibration of miniature PRTs, prior to their assembly in the mirrors of state-of-the-art optical dew-point hygrometers and their subsequent calibration as dew-point temperature measurement devices, has been investigated. Standard humidity generators of three NMIs were used to calibrate hygrometers of different designs, covering the dew-point temperature range from -75 °C to + 95 °C. The results span more than a decade, during which time successive improvements and modifications were implemented by the manufacturer. The findings are presented and discussed in the context of enabling the optimum use of these transfer standards and as a basis for determining contributions to the uncertainty in their calibration.

  3. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform.

    PubMed

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-07-15

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional "chilled-mirror" hygrometers. Moreover, this DPS outperforms conventional "chilled-mirror" hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.

  4. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform

    NASA Astrophysics Data System (ADS)

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-07-01

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.

  5. [Applicability of syalometry and other instruments to evaluate xerostomia and xerophtalmia in a Sjögren's Syndrome outpatient clinic].

    PubMed

    Barcelos, Filipe; Patto, José Vaz; Parente, Manuela; Medeiros, Dina; Sousa, Miguel; Figueiredo, Rui; Miguel, Cláudia; Teixeira, Ana

    2009-01-01

    To evaluate the applicability and utility of unstimulated syalometry and instruments of evaluation of sicca complaints in a Sjögren's syndrome outpatient clinic. We performed unstimulated syalometry to 45 consecutive Primary Sjögren's Syndrome patients (PSS) and 21 healthy asymptomatic individuals age and sex-matched. PSS patients were further evaluated with Schirmer's test. We applied 3 published questionnaires to PSS patients: Xerostomia Inventory (XI), Oral Health Impact Profile-short form (OHIP) and Ocular Surface Disease Index (OSDI), and correlated the results with syalometry and Schirmer's test. Statistical analysis was performed with SPSS (Mann-Whitney U-test and Spearman's correlation). Salivary flux was significantly lower in PSS patients, as compared to controls (0.08+/-0.01 ml/min versus 0.38+/-0.25 ml/min, p=0.000), and decreased with age. Syalometry didn't correlate with Schirmer's test. OHIP scores (mean 26.8 points, ranging from 2 to 43 for a maximum of 56 points) didn't correlate with syalometry neither with Schirmer's test, but showed an association with the XI (p<0.0005) and OSDI (p<0.0005) tests. The XI questionnaire (mean 28.4 points, ranging from 11 to 41 for a maximum of 44 points) correlated with syalometry (p=0.018), with the OHIP questionary (p<0.0005) and with the OSDI scale (p=0.004), although it didn't correlate with Schirmer's test. OSDI scores (mean 56.5 points, ranging from 7 to 90 for a maximum of 100 points) didn't correlate with Schirmer's test neither with syalometry, but associated with the XI (p=0.004) and OHIP (p<0.0005) scales. Unstimulated syalometry is useful in the evaluation of patients suspected of suffering from Sjögren's syndrome, since it can confirm salivary hypofunction in a quick and cheap manner, allowing to differentiate between healthy individuals and patients. In a specialized clinic, the immediate availability of a salivary functional test is important in the classification of PSS or sicca syndrome. The xerostomia and xerophtalmia impact scales were mutually concordant, and since they evaluate the effects of the disease through time, could be helpful in our daily consultation.

  6. Miniature near-infrared spectrometer for point-of-use chemical analysis

    NASA Astrophysics Data System (ADS)

    Friedrich, Donald M.; Hulse, Charles A.; von Gunten, Marc; Williamson, Eric P.; Pederson, Christopher G.; O'Brien, Nada A.

    2014-03-01

    Point-of-use chemical analysis holds tremendous promise for a number of industries, including agriculture, recycling, pharmaceuticals and homeland security. Near infrared (NIR) spectroscopy is an excellent candidate for these applications, with minimal sample preparation for real-time decision-making. We will detail the development of a golf ball-sized NIR spectrometer developed specifically for this purpose. The instrument is based upon a thin-film dispersive element that is very stable over time and temperature, with less than 2 nm change expected over the operating temperature range and lifetime of the instrument. This filter is coupled with an uncooled InGaAs detector array in a small, rugged, environmentally stable optical bench ideally suited to unpredictable environments. The resulting instrument weighs less than 60 grams, includes onboard illumination and collection optics for diffuse reflectance applications in the 900-1700 nm wavelength range, and is USB-powered. It can be driven in the field by a laptop, tablet or even a smartphone. The software design includes the potential for both on-board and cloud-based storage, analysis and decision-making. The key attributes of the instrument and the underlying design tradeoffs will be discussed, focusing on miniaturization, ruggedization, power consumption and cost. The optical performance of the instrument, as well as its fit-for purpose will be detailed. Finally, we will show that our manufacturing process has enabled us to build instruments with excellent unit-to-unit reproducibility. We will show that this is a key enabler for instrumentindependent chemical analysis models, a requirement for mass point-of-use deployment.

  7. Multiplicative point process as a model of trading activity

    NASA Astrophysics Data System (ADS)

    Gontis, V.; Kaulakys, B.

    2004-11-01

    Signals consisting of a sequence of pulses show that inherent origin of the 1/ f noise is a Brownian fluctuation of the average interevent time between subsequent pulses of the pulse sequence. In this paper, we generalize the model of interevent time to reproduce a variety of self-affine time series exhibiting power spectral density S( f) scaling as a power of the frequency f. Furthermore, we analyze the relation between the power-law correlations and the origin of the power-law probability distribution of the signal intensity. We introduce a stochastic multiplicative model for the time intervals between point events and analyze the statistical properties of the signal analytically and numerically. Such model system exhibits power-law spectral density S( f)∼1/ fβ for various values of β, including β= {1}/{2}, 1 and {3}/{2}. Explicit expressions for the power spectra in the low-frequency limit and for the distribution density of the interevent time are obtained. The counting statistics of the events is analyzed analytically and numerically, as well. The specific interest of our analysis is related with the financial markets, where long-range correlations of price fluctuations largely depend on the number of transactions. We analyze the spectral density and counting statistics of the number of transactions. The model reproduces spectral properties of the real markets and explains the mechanism of power-law distribution of trading activity. The study provides evidence that the statistical properties of the financial markets are enclosed in the statistics of the time interval between trades. A multiplicative point process serves as a consistent model generating this statistics.

  8. Reduction in menopause-related symptoms associated with use of a noninvasive neurotechnology for autocalibration of neural oscillations.

    PubMed

    Tegeler, Charles H; Tegeler, Catherine L; Cook, Jared F; Lee, Sung W; Pajewski, Nicholas M

    2015-06-01

    Increased amplitudes in high-frequency brain electrical activity are reported with menopausal hot flashes. We report outcomes associated with the use of High-resolution, relational, resonance-based, electroencephalic mirroring--a noninvasive neurotechnology for autocalibration of neural oscillations--by women with perimenopausal and postmenopausal hot flashes. Twelve women with hot flashes (median age, 56 y; range, 46-69 y) underwent a median of 13 (range, 8-23) intervention sessions for a median of 9.5 days (range, 4-32). This intervention uses algorithmic analysis of brain electrical activity and near real-time translation of brain frequencies into variable tones for acoustic stimulation. Hot flash frequency and severity were recorded by daily diary. Primary outcomes included hot flash severity score, sleep, and depressive symptoms. High-frequency amplitudes (23-36 Hz) from bilateral temporal scalp recordings were measured at baseline and during serial sessions. Self-reported symptom inventories for sleep and depressive symptoms were collected. The median change in hot flash severity score was -0.97 (range, -3.00 to 1.00; P = 0.015). Sleep and depression scores decreased by -8.5 points (range, -20 to -1; P = 0.022) and -5.5 points (range, -32 to 8; P = 0.015), respectively. The median sum of amplitudes for the right and left temporal high-frequency brain electrical activity was 8.44 μV (range, 6.27-16.66) at baseline and decreased by a median of -2.96 μV (range, -11.05 to -0.65; P = 0.0005) by the final session. Hot flash frequency and severity, symptoms of insomnia and depression, and temporal high-frequency brain electrical activity decrease after High-resolution, relational, resonance-based, electroencephalic mirroring. Larger controlled trials with longer follow-up are warranted.

  9. Two-Dimensional SIR Epidemics with Long Range Infection

    NASA Astrophysics Data System (ADS)

    Grassberger, Peter

    2013-10-01

    We extend a recent study of susceptible-infected-removed epidemic processes with long range infection (referred to as I in the following) from 1-dimensional lattices to lattices in two dimensions. As in I we use hashing to simulate very large lattices for which finite size effects can be neglected, in spite of the assumed power law p( x)˜| x|- σ-2 for the probability that a site can infect another site a distance vector x apart. As in I we present detailed results for the critical case, for the supercritical case with σ=2, and for the supercritical case with 0< σ<2. For the latter we verify the stretched exponential growth of the infected cluster with time predicted by M. Biskup. For σ=2 we find generic power laws with σ-dependent exponents in the supercritical phase, but no Kosterlitz-Thouless (KT) like critical point as in 1-d. Instead of diverging exponentially with the distance from the critical point, the correlation length increases with an inverse power, as in an ordinary critical point. Finally we study the dependence of the critical exponents on σ in the regime 0< σ<2, and compare with field theoretic predictions. In particular we discuss in detail whether the critical behavior for σ slightly less than 2 is in the short range universality class, as conjectured recently by F. Linder et al. As in I we also consider a modified version of the model where only some of the contacts are long range, the others being between nearest neighbors. If the number of the latter reaches the percolation threshold, the critical behavior is changed but the supercritical behavior stays qualitatively the same.

  10. Responsiveness and MCID Estimates for CAT, CCQ, and HADS in Patients With COPD Undergoing Pulmonary Rehabilitation: A Prospective Analysis.

    PubMed

    Smid, Dionne E; Franssen, Frits M E; Houben-Wilke, Sarah; Vanfleteren, Lowie E G W; Janssen, Daisy J A; Wouters, Emiel F M; Spruit, Martijn A

    2017-01-01

    Pulmonary rehabilitation enhances health status and mood status in patients with chronic obstructive pulmonary disease (COPD). The aim was to determine the responsiveness of St. George's Respiratory Questionnaire (SGRQ), COPD Assessment Test (CAT), COPD Clinical Questionnaire (CCQ), and Hospital Anxiety and Depression Scale (HADS) to pulmonary rehabilitation in patients with COPD, and estimate minimum clinically important differences (MCIDs) for CAT, CCQ, and HADS. A prospective analysis. MCIDs were estimated with anchor-based (anchor: SGRQ) and distribution-based methods. Newly estimated MCIDs were compared to known MCID estimates from a systematic literature search. Newly estimated MCIDs were calculated in patients treated in pulmonary rehabilitation. A subsample of 419 individuals with COPD (55.4% male, mean age 64.3 ± 8.8 years) were included from the Chance study. Health status was measured with SGRQ, CAT, and CCQ, before and after pulmonary rehabilitation. Mood status was assessed using HADS. 419 patients with COPD (forced expiratory volume in the first second 37.3% ± 12.1% predicted) completed pulmonary rehabilitation. SGRQ (-9.1 ± 14.0 points), CAT (-3.0 ± 6.8 points), CCQ (-0.6 ± 0.9 points), HADS-Anxiety (-1.7 ± 3.7 points), and HADS-Depression (-2.1 ± 3.7 points) improved significantly. New MCIDs were estimated for CAT (range: -3.8 to -1.0 points), CCQ (range: -0.8 to -0.2 points), HADS-Anxiety (range: -2.0 to -1.1 points), and HADS-Depression (range: -1.8 to -1.4 points). The SGRQ, CAT, CCQ, and HADS are responsive to pulmonary rehabilitation in patients with COPD. We propose MCID estimates ranging between -3.0 and -2.0 points for CAT; -0.5 and -0.3 points for CCQ, -1.8 and -1.3 points for HADS-Anxiety, and -1.7 and -1.5 points for HADS-Depression. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  11. SU-F-SPS-09: Parallel MC Kernel Calculations for VMAT Plan Improvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamberlain, S; Roswell Park Cancer Institute, Buffalo, NY; French, S

    Purpose: Adding kernels (small perturbations in leaf positions) to the existing apertures of VMAT control points may improve plan quality. We investigate the calculation of kernel doses using a parallelized Monte Carlo (MC) method. Methods: A clinical prostate VMAT DICOM plan was exported from Eclipse. An arbitrary control point and leaf were chosen, and a modified MLC file was created, corresponding to the leaf position offset by 0.5cm. The additional dose produced by this 0.5 cm × 0.5 cm kernel was calculated using the DOSXYZnrc component module of BEAMnrc. A range of particle history counts were run (varying from 3more » × 10{sup 6} to 3 × 10{sup 7}); each job was split among 1, 10, or 100 parallel processes. A particle count of 3 × 10{sup 6} was established as the lower range because it provided the minimal accuracy level. Results: As expected, an increase in particle counts linearly increases run time. For the lowest particle count, the time varied from 30 hours for the single-processor run, to 0.30 hours for the 100-processor run. Conclusion: Parallel processing of MC calculations in the EGS framework significantly decreases time necessary for each kernel dose calculation. Particle counts lower than 1 × 10{sup 6} have too large of an error to output accurate dose for a Monte Carlo kernel calculation. Future work will investigate increasing the number of parallel processes and optimizing run times for multiple kernel calculations.« less

  12. Small geographic range but not panmictic: how forests structure the endangered Point Arena mountain beaver (Aplodontia rufa nigra)

    Treesearch

    William J. Zielinski; Fredrick V. Schlexer; Sean A. Parks; Kristine L. Pilgrim; Michael K. Schwartz

    2012-01-01

    The landscape genetics framework is typically applied to broad regions that occupy only small portions of a species' range. Rarely is the entire range of a taxon the subject of study. We examined the landscape genetic structure of the endangered Point Arena mountain beaver (Aplodontia rufa nigra), whose isolated geographic range is found in a...

  13. Home Use of Day-and-Night Hybrid Closed-Loop Insulin Delivery in Suboptimally Controlled Adolescents With Type 1 Diabetes: A 3-Week, Free-Living, Randomized Crossover Trial.

    PubMed

    Tauschmann, Martin; Allen, Janet M; Wilinska, Malgorzata E; Thabit, Hood; Acerini, Carlo L; Dunger, David B; Hovorka, Roman

    2016-11-01

    This study evaluated the feasibility, safety, and efficacy of day-and-night hybrid closed-loop insulin delivery in adolescents with type 1 diabetes under free-living conditions. In an open-label randomized crossover study, 12 suboptimally controlled adolescents on insulin pump therapy (mean ± SD age 14.6 ± 3.1 years; HbA 1c 69 ± 8 mmol/mol [8.5 ± 0.7%]; duration of diabetes 7.8 ± 3.5 years) underwent two 21-day periods in which hybrid closed-loop insulin delivery was compared with sensor-augmented insulin pump therapy in random order. During the closed-loop intervention, a model predictive algorithm automatically directed insulin delivery between meals and overnight. Participants used a bolus calculator to administer prandial boluses. The proportion of time that sensor glucose was in the target range (3.9-10 mmol/L; primary end point) was increased during the closed-loop intervention compared with sensor-augmented insulin pump therapy by 18.8 ± 9.8 percentage points (mean ± SD; P < 0.001), the mean sensor glucose level was reduced by 1.8 ± 1.3 mmol/L (P = 0.001), and the time spent above target was reduced by 19.3 ± 11.3 percentage points (P < 0.001). The time spent with sensor glucose levels below 3.9 mmol/L was low and comparable between interventions (median difference 0.4 [interquartile range -2.2 to 1.3] percentage points; P = 0.33). Improved glucose control during closed-loop was associated with increased variability of basal insulin delivery (P < 0.001) and an increase in the total daily insulin dose (53.5 [39.5-72.1] vs. 51.5 [37.6-64.3] units/day; P = 0.006). Participants expressed positive attitudes and experience with the closed-loop system. Free-living home use of day-and-night closed-loop in suboptimally controlled adolescents with type 1 diabetes is safe, feasible, and improves glucose control without increasing the risk of hypoglycemia. Larger and longer studies are warranted. © 2016 by the American Diabetes Association.

  14. Infinite-disorder critical points of models with stretched exponential interactions

    NASA Astrophysics Data System (ADS)

    Juhász, Róbert

    2014-09-01

    We show that an interaction decaying as a stretched exponential function of distance, J(l)˜ e-cl^a , is able to alter the universality class of short-range systems having an infinite-disorder critical point. To do so, we study the low-energy properties of the random transverse-field Ising chain with the above form of interaction by a strong-disorder renormalization group (SDRG) approach. We find that the critical behavior of the model is controlled by infinite-disorder fixed points different from those of the short-range model if 0 < a < 1/2. In this range, the critical exponents calculated analytically by a simplified SDRG scheme are found to vary with a, while, for a > 1/2, the model belongs to the same universality class as its short-range variant. The entanglement entropy of a block of size L increases logarithmically with L at the critical point but, unlike the short-range model, the prefactor is dependent on disorder in the range 0 < a < 1/2. Numerical results obtained by an improved SDRG scheme are found to be in agreement with the analytical predictions. The same fixed points are expected to describe the critical behavior of, among others, the random contact process with stretched exponentially decaying activation rates.

  15. Set membership experimental design for biological systems.

    PubMed

    Marvel, Skylar W; Williams, Cranos M

    2012-03-21

    Experimental design approaches for biological systems are needed to help conserve the limited resources that are allocated for performing experiments. The assumptions used when assigning probability density functions to characterize uncertainty in biological systems are unwarranted when only a small number of measurements can be obtained. In these situations, the uncertainty in biological systems is more appropriately characterized in a bounded-error context. Additionally, effort must be made to improve the connection between modelers and experimentalists by relating design metrics to biologically relevant information. Bounded-error experimental design approaches that can assess the impact of additional measurements on model uncertainty are needed to identify the most appropriate balance between the collection of data and the availability of resources. In this work we develop a bounded-error experimental design framework for nonlinear continuous-time systems when few data measurements are available. This approach leverages many of the recent advances in bounded-error parameter and state estimation methods that use interval analysis to generate parameter sets and state bounds consistent with uncertain data measurements. We devise a novel approach using set-based uncertainty propagation to estimate measurement ranges at candidate time points. We then use these estimated measurements at the candidate time points to evaluate which candidate measurements furthest reduce model uncertainty. A method for quickly combining multiple candidate time points is presented and allows for determining the effect of adding multiple measurements. Biologically relevant metrics are developed and used to predict when new data measurements should be acquired, which system components should be measured and how many additional measurements should be obtained. The practicability of our approach is illustrated with a case study. This study shows that our approach is able to 1) identify candidate measurement time points that maximize information corresponding to biologically relevant metrics and 2) determine the number at which additional measurements begin to provide insignificant information. This framework can be used to balance the availability of resources with the addition of one or more measurement time points to improve the predictability of resulting models.

  16. Set membership experimental design for biological systems

    PubMed Central

    2012-01-01

    Background Experimental design approaches for biological systems are needed to help conserve the limited resources that are allocated for performing experiments. The assumptions used when assigning probability density functions to characterize uncertainty in biological systems are unwarranted when only a small number of measurements can be obtained. In these situations, the uncertainty in biological systems is more appropriately characterized in a bounded-error context. Additionally, effort must be made to improve the connection between modelers and experimentalists by relating design metrics to biologically relevant information. Bounded-error experimental design approaches that can assess the impact of additional measurements on model uncertainty are needed to identify the most appropriate balance between the collection of data and the availability of resources. Results In this work we develop a bounded-error experimental design framework for nonlinear continuous-time systems when few data measurements are available. This approach leverages many of the recent advances in bounded-error parameter and state estimation methods that use interval analysis to generate parameter sets and state bounds consistent with uncertain data measurements. We devise a novel approach using set-based uncertainty propagation to estimate measurement ranges at candidate time points. We then use these estimated measurements at the candidate time points to evaluate which candidate measurements furthest reduce model uncertainty. A method for quickly combining multiple candidate time points is presented and allows for determining the effect of adding multiple measurements. Biologically relevant metrics are developed and used to predict when new data measurements should be acquired, which system components should be measured and how many additional measurements should be obtained. Conclusions The practicability of our approach is illustrated with a case study. This study shows that our approach is able to 1) identify candidate measurement time points that maximize information corresponding to biologically relevant metrics and 2) determine the number at which additional measurements begin to provide insignificant information. This framework can be used to balance the availability of resources with the addition of one or more measurement time points to improve the predictability of resulting models. PMID:22436240

  17. Relationships between Participants' International Prostate Symptom Score and BPH Impact Index Changes and Global Ratings of Change in a Trial of Phytotherapy for Men with Lower Urinary Tract Symptoms

    PubMed Central

    Barry, Michael J.; Cantor, Alan; Roehrborn, Claus G.

    2014-01-01

    Purpose To relate changes in AUA Symptom Index (AUASI) scores with bother measures and global ratings of change among men with lower urinary tract symptoms enrolled in a trial of saw palmetto. Materials and Methods To be eligible, men were ≥45 years old, had ajpeak uroflow ≥4 ml/sec, and an AUASI score ≥ 8 and ≤ 24. Participants self-administered the AUASI, IPSS quality of life item (IPSS QoL), BPH Impact Index (BII) and two global change questions at baseline and 24, 48, and 72 weeks. Results Among 357 participants, global ratings of “a little better” were associated with mean decreases in AUASI scores from 2.8 to 4.1 points, across three time points. The analogous range for mean decreases in BII scores was 1.0 to 1.7 points, and for the IPSS QoL item 0.5 to 0.8 points. At 72 weeks, for the first global change question, each change measure could discriminate between participants rating themselves at least a little better versus unchanged or worse 70-72% of the time. A multivariable model increased discrimination to 77%. For the second global change question, each change measure correctly discriminated ratings of at least a little better versus unchanged or worse 69-74% of the time, and a multivariable model increased discrimination to 79%. Conclusions Changes in AUASI scores could discriminate between participants rating themselves at least a little better versus unchanged or worse. Our findings support the practice of powering studies to detect group mean differences in AUASI scores of at least 3 points. PMID:23017510

  18. Surgeons' Leadership Styles and Team Behavior in the Operating Room.

    PubMed

    Hu, Yue-Yung; Parker, Sarah Henrickson; Lipsitz, Stuart R; Arriaga, Alexander F; Peyre, Sarah E; Corso, Katherine A; Roth, Emilie M; Yule, Steven J; Greenberg, Caprice C

    2016-01-01

    The importance of leadership is recognized in surgery, but the specific impact of leadership style on team behavior is not well understood. In other industries, leadership is a well-characterized construct. One dominant theory proposes that transactional (task-focused) leaders achieve minimum standards and transformational (team-oriented) leaders inspire performance beyond expectations. We videorecorded 5 surgeons performing complex operations. Each surgeon was scored on the Multifactor Leadership Questionnaire, a validated method for scoring transformational and transactional leadership style, by an organizational psychologist and a surgeon researcher. Independent coders assessed surgeons' leadership behaviors according to the Surgical Leadership Inventory and team behaviors (information sharing, cooperative, and voice behaviors). All coders were blinded. Leadership style (Multifactor Leadership Questionnaire) was correlated with surgeon behavior (Surgical Leadership Inventory) and team behavior using Poisson regression, controlling for time and the total number of behaviors, respectively. All surgeons scored similarly on transactional leadership (range 2.38 to 2.69), but varied more widely on transformational leadership (range 1.98 to 3.60). Each 1-point increase in transformational score corresponded to 3 times more information-sharing behaviors (p < 0.0001) and 5.4 times more voice behaviors (p = 0.0005) among the team. With each 1-point increase in transformational score, leaders displayed 10 times more supportive behaviors (p < 0.0001) and displayed poor behaviors 12.5 times less frequently (p < 0.0001). Excerpts of representative dialogue are included for illustration. We provide a framework for evaluating surgeons' leadership and its impact on team performance in the operating room. As in other fields, our data suggest that transformational leadership is associated with improved team behavior. Surgeon leadership development, therefore, has the potential to improve the efficiency and safety of operative care. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A fast analytical undulator model for realistic high-energy FEL simulations

    NASA Astrophysics Data System (ADS)

    Tatchyn, R.; Cremer, T.

    1997-02-01

    A number of leading FEL simulation codes used for modeling gain in the ultralong undulators required for SASE saturation in the <100 Å range employ simplified analytical models both for field and error representations. Although it is recognized that both the practical and theoretical validity of such codes could be enhanced by incorporating realistic undulator field calculations, the computational cost of doing this can be prohibitive, especially for point-to-point integration of the equations of motion through each undulator period. In this paper we describe a simple analytical model suitable for modeling realistic permanent magnet (PM), hybrid/PM, and non-PM undulator structures, and discuss selected techniques for minimizing computation time.

  20. DTI study of Children with Congenital Hydrocephalus: 1 Year Post-Surgical Outcomes

    PubMed Central

    Mangano, Francesco T.; Altaye, Mekibib; McKinstry, Robert C.; Shimony, Joshua S.; Powell, Stephanie K.; Phillips, Jannel M.; Barnard, Holly; Limbrick, David D.; Holland, Scott K.; Jones, Blaise V.; Dodd, Jonathon; Simpson, Sarah; Deanna, Mercer; Rajagopal, Akila; Bidwell, Sarah; Yuan, Weihong

    2016-01-01

    Object To investigate white matter structural abnormalities using diffusion tensor imaging (DTI) in children with hydrocephalus before CSF diversionary surgery (including ventriculoperitoneal shunting and endoscopic third ventriculoscopy) and the course of recovery post-surgery in association with neuropsychological and behavioral outcome. Methods This was a prospective study that included 54 children with congenital hydrocephalus (21F/33M; age range: 0.03–194.5 months) who underwent surgery and 64 normal controls (30F/34M, age range: 0.30–197.75 months). DTI and neurodevelopmental outcome data were collected once in the control group and at pre-surgery, 3-month, and 12-month post-surgery in the patients. DTI measures, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) values were extracted from the genu of corpus callosum (gCC) and the posterior limb of internal capsule (PLIC). Group analysis was performed first cross-sectionally to quantify DTI abnormalities at three time points by comparing the controls and the patients group at the three time points separately. Longitudinal comparisons were conducted pairwise between different time points in patients whose data were acquired at multiple time points. Neurodevelopmental data were collected and analyzed using the Adaptive Behavior Assessment System, Second Edition (ABAS-II) and the Bayley Scales of Infant Development, Third Edition (Bayley-III). Correlation analyses were performed between DTI and behavioral outcomes. Results Significant DTI abnormalities were found in both the gCC (lower FA and higher MD, AD, and RD) and the PLIC (higher FA, lower AD and RD) at pre-surgery. The DTI measures in the gCC remained mostly abnormal at 3-month and 12-month post-surgery. The DTI abnormalities in the PLIC were significant in FA and AD at 3-month post-surgery but did nor persist when tested at 12-month post-surgery. Significant longitudinal DTI changes in the patients were found in the gCC between 3-month and 12-month post-surgery. In the PLIC, trend level longitudinal changes were found between pre-surgery and 3-month post-surgery as well as between 3-month and 12-month post-surgery. Significant correlation between DTI and developmental outcome were found at all three time points. Notably, significant correlation was found between DTI in the PLIC at 3-month post-surgery and developmental outcome at 12-month pots-surgery. Conclusion Our data showed significant WM abnormality based on DTI in both the gCC and the PLIC in children with congenital hydrocephalus before surgery and the abnormalities persisted in both the gCC and the PLIC at 3-month post-surgery. The DTI values remained significantly abnormal in the gCC at 12-month post-surgery. Longitudinal analysis showed signs of recovery in both WM structures between different time points. Combined with the significant correlation found between DTI and neuropsychological outcome, our study suggests that DTI can serve as a sensitive imaging biomarker for underlying neuroanatomical changes and post-surgical developmental outcome and even as a predictor for future outcomes. PMID:27203134

  1. easyCBM Beginning Reading Measures: Grades K-1 Alternate Form Reliability and Criterion Validity with the SAT-10. Technical Report #1403

    ERIC Educational Resources Information Center

    Wray, Kraig; Lai, Cheng-Fei; Sáez, Leilani; Alonzo, Julie; Tindal, Gerald

    2013-01-01

    We report the results of an alternate form reliability and criterion validity study of kindergarten and grade 1 (N = 84-199) reading measures from the easyCBM© assessment system and Stanford Early School Achievement Test/Stanford Achievement Test, 10th edition (SESAT/SAT-­10) across 5 time points. The alternate form reliabilities ranged from…

  2. Induction of cold hardiness in an invasive herbivore: The case of hemlock woolly adelgid (Hemiptera: Adelgidae)

    Treesearch

    Joseph S. Elkinton; Jeffrey A. Lombardo; Artemis D. Roehrig; Thomas J. McAvoy; Albert Mayfield; Mark Whitmore

    2017-01-01

    As a measure of cold hardiness, we tested the supercooling points or freezing temperatures of individual hemlock woolly adelgids (Adelges tsugae Annand) collected from 15 locations across the north to south range of the adelgid in eastern North America at different times during two winters. Adelgids from the northern interior locations with USDA hardiness zones of 5B–...

  3. Magnetic STAR technology for real-time localization and classification of unexploded ordnance and buried mines

    NASA Astrophysics Data System (ADS)

    Wiegert, R. F.

    2009-05-01

    A man-portable Magnetic Scalar Triangulation and Ranging ("MagSTAR") technology for Detection, Localization and Classification (DLC) of unexploded ordnance (UXO) has been developed by Naval Surface Warfare Center Panama City Division (NSWC PCD) with support from the Strategic Environmental Research and Development Program (SERDP). Proof of principle of the MagSTAR concept and its unique advantages for real-time, high-mobility magnetic sensing applications have been demonstrated by field tests of a prototype man-portable MagSTAR sensor. The prototype comprises: a) An array of fluxgate magnetometers configured as a multi-tensor gradiometer, b) A GPS-synchronized signal processing system. c) Unique STAR algorithms for point-by-point, standoff DLC of magnetic targets. This paper outlines details of: i) MagSTAR theory, ii) Design and construction of the prototype sensor, iii) Signal processing algorithms recently developed to improve the technology's target-discrimination accuracy, iv) Results of field tests of the portable gradiometer system against magnetic dipole targets. The results demonstrate that the MagSTAR technology is capable of very accurate, high-speed localization of magnetic targets at standoff distances of several meters. These advantages could readily be transitioned to a wide range of defense, security and sensing applications to provide faster and more effective DLC of UXO and buried mines.

  4. Physical activity during pregnancy: impact of applying different physical activity guidelines.

    PubMed

    Smith, Katie M; Campbell, Christina G

    2013-01-01

    Multiple guidelines and definitions of physical activity (PA) have been used to study the benefits of activity during pregnancy. The different guidelines lead to a wide range of prevalence estimates and this has led to conflicting reports about activity patterns during pregnancy. A longitudinal study was conducted to assess PA using a pattern-recognition monitor for a 7-day period at week 18 (n = 55) and week 35 (n = 66) of pregnancy. The amount of activity performed and the number of women meeting six different PA guidelines were evaluated. Adherence to PA guidelines ranged from 5 to 100% and 9 to 100% at weeks 18 and 35, respectively. All women achieved the 500 MET-minute guideline and nearly all women accumulated ≥150 minutes of weekly moderate-vigorous physical activity (MVPA) at both time points. Only 22% and 26% participated in ≥3 sessions of MVPA lasting ≥30 minutes at both time points and this further declined to 5% and 9% when the guideline was increased to ≥5 sessions of 30 minutes. The amount of PA during pregnancy varied drastically depending on which guideline was used. Further research is warranted to clearly identify the patterns of activity that are associated with healthy pregnancy outcomes.

  5. Physical Activity during Pregnancy: Impact of Applying Different Physical Activity Guidelines

    PubMed Central

    Smith, Katie M.; Campbell, Christina G.

    2013-01-01

    Multiple guidelines and definitions of physical activity (PA) have been used to study the benefits of activity during pregnancy. The different guidelines lead to a wide range of prevalence estimates and this has led to conflicting reports about activity patterns during pregnancy. A longitudinal study was conducted to assess PA using a pattern-recognition monitor for a 7-day period at week 18 (n = 55) and week 35 (n = 66) of pregnancy. The amount of activity performed and the number of women meeting six different PA guidelines were evaluated. Adherence to PA guidelines ranged from 5 to 100% and 9 to 100% at weeks 18 and 35, respectively. All women achieved the 500 MET-minute guideline and nearly all women accumulated ≥150 minutes of weekly moderate-vigorous physical activity (MVPA) at both time points. Only 22% and 26% participated in ≥3 sessions of MVPA lasting ≥30 minutes at both time points and this further declined to 5% and 9% when the guideline was increased to ≥5 sessions of 30 minutes. The amount of PA during pregnancy varied drastically depending on which guideline was used. Further research is warranted to clearly identify the patterns of activity that are associated with healthy pregnancy outcomes. PMID:23476778

  6. Measuring the development of inhibitory control: The challenge of heterotypic continuity

    PubMed Central

    Petersen, Isaac T.; Hoyniak, Caroline P.; McQuillan, Maureen E.; Bates, John E.; Staples, Angela D.

    2016-01-01

    Inhibitory control is thought to demonstrate heterotypic continuity, in other words, continuity in its purpose or function but changes in its behavioral manifestation over time. This creates major methodological challenges for studying the development of inhibitory control in childhood including construct validity, developmental appropriateness and sensitivity of measures, and longitudinal factorial invariance. We meta-analyzed 198 studies using measures of inhibitory control, a key aspect of self-regulation, to estimate age ranges of usefulness for each measure. The inhibitory control measures showed limited age ranges of usefulness owing to ceiling/floor effects. Tasks were useful, on average, for a developmental span of less than 3 years. This suggests that measuring inhibitory control over longer spans of development may require use of different measures at different time points, seeking to measure heterotypic continuity. We suggest ways to study the development of inhibitory control, with overlapping measurement in a structural equation modeling framework and tests of longitudinal factorial or measurement invariance. However, as valuable as this would be for the area, we also point out that establishing longitudinal factorial invariance is neither sufficient nor necessary for examining developmental change. Any study of developmental change should be guided by theory and construct validity, aiming toward a better empirical and theoretical approach to the selection and combination of measures. PMID:27346906

  7. Distributed fiber sparse-wideband vibration sensing by sub-Nyquist additive random sampling

    NASA Astrophysics Data System (ADS)

    Zhang, Jingdong; Zheng, Hua; Zhu, Tao; Yin, Guolu; Liu, Min; Bai, Yongzhong; Qu, Dingrong; Qiu, Feng; Huang, Xianbing

    2018-05-01

    The round trip time of the light pulse limits the maximum detectable vibration frequency response range of phase-sensitive optical time domain reflectometry ({\\phi}-OTDR). Unlike the uniform laser pulse interval in conventional {\\phi}-OTDR, we randomly modulate the pulse interval, so that an equivalent sub-Nyquist additive random sampling (sNARS) is realized for every sensing point of the long interrogation fiber. For an {\\phi}-OTDR system with 10 km sensing length, the sNARS method is optimized by theoretical analysis and Monte Carlo simulation, and the experimental results verify that a wide-band spars signal can be identified and reconstructed. Such a method can broaden the vibration frequency response range of {\\phi}-OTDR, which is of great significance in sparse-wideband-frequency vibration signal detection, such as rail track monitoring and metal defect detection.

  8. Automatic Registration of TLS-TLS and TLS-MLS Point Clouds Using a Genetic Algorithm

    PubMed Central

    Yan, Li; Xie, Hong; Chen, Changjun

    2017-01-01

    Registration of point clouds is a fundamental issue in Light Detection and Ranging (LiDAR) remote sensing because point clouds scanned from multiple scan stations or by different platforms need to be transformed to a uniform coordinate reference frame. This paper proposes an efficient registration method based on genetic algorithm (GA) for automatic alignment of two terrestrial LiDAR scanning (TLS) point clouds (TLS-TLS point clouds) and alignment between TLS and mobile LiDAR scanning (MLS) point clouds (TLS-MLS point clouds). The scanning station position acquired by the TLS built-in GPS and the quasi-horizontal orientation of the LiDAR sensor in data acquisition are used as constraints to narrow the search space in GA. A new fitness function to evaluate the solutions for GA, named as Normalized Sum of Matching Scores, is proposed for accurate registration. Our method is divided into five steps: selection of matching points, initialization of population, transformation of matching points, calculation of fitness values, and genetic operation. The method is verified using a TLS-TLS data set and a TLS-MLS data set. The experimental results indicate that the RMSE of registration of TLS-TLS point clouds is 3~5 mm, and that of TLS-MLS point clouds is 2~4 cm. The registration integrating the existing well-known ICP with GA is further proposed to accelerate the optimization and its optimizing time decreases by about 50%. PMID:28850100

  9. Automatic Registration of TLS-TLS and TLS-MLS Point Clouds Using a Genetic Algorithm.

    PubMed

    Yan, Li; Tan, Junxiang; Liu, Hua; Xie, Hong; Chen, Changjun

    2017-08-29

    Registration of point clouds is a fundamental issue in Light Detection and Ranging (LiDAR) remote sensing because point clouds scanned from multiple scan stations or by different platforms need to be transformed to a uniform coordinate reference frame. This paper proposes an efficient registration method based on genetic algorithm (GA) for automatic alignment of two terrestrial LiDAR scanning (TLS) point clouds (TLS-TLS point clouds) and alignment between TLS and mobile LiDAR scanning (MLS) point clouds (TLS-MLS point clouds). The scanning station position acquired by the TLS built-in GPS and the quasi-horizontal orientation of the LiDAR sensor in data acquisition are used as constraints to narrow the search space in GA. A new fitness function to evaluate the solutions for GA, named as Normalized Sum of Matching Scores, is proposed for accurate registration. Our method is divided into five steps: selection of matching points, initialization of population, transformation of matching points, calculation of fitness values, and genetic operation. The method is verified using a TLS-TLS data set and a TLS-MLS data set. The experimental results indicate that the RMSE of registration of TLS-TLS point clouds is 3~5 mm, and that of TLS-MLS point clouds is 2~4 cm. The registration integrating the existing well-known ICP with GA is further proposed to accelerate the optimization and its optimizing time decreases by about 50%.

  10. Comparison of DSMs acquired by terrestrial laser scanning, UAV-based aerial images and ground-based optical images at the Super-Sauze landslide

    NASA Astrophysics Data System (ADS)

    Rothmund, Sabrina; Niethammer, Uwe; Walter, Marco; Joswig, Manfred

    2013-04-01

    In recent years, the high-resolution and multi-temporal 3D mapping of the Earth's surface using terrestrial laser scanning (TLS), ground-based optical images and especially low-cost UAV-based aerial images (Unmanned Aerial Vehicle) has grown in importance. This development resulted from the progressive technical improvement of the imaging systems and the freely available multi-view stereo (MVS) software packages. These different methods of data acquisition for the generation of accurate, high-resolution digital surface models (DSMs) were applied as part of an eight-week field campaign at the Super-Sauze landslide (South French Alps). An area of approximately 10,000 m² with long-term average displacement rates greater than 0.01 m/day has been investigated. The TLS-based point clouds were acquired at different viewpoints with an average point spacing between 10 to 40 mm and at different dates. On these days, more than 50 optical images were taken on points along a predefined line on the side part of the landslide by a low-cost digital compact camera. Additionally, aerial images were taken by a radio-controlled mini quad-rotor UAV equipped with another low-cost digital compact camera. The flight altitude ranged between 20 m and 250 m and produced a corresponding ground resolution between 0.6 cm and 7 cm. DGPS measurements were carried out as well in order to geo-reference and validate the point cloud data. To generate unscaled photogrammetric 3D point clouds from a disordered and tilted image set, we use the widespread open-source software package Bundler and PMVS2 (University of Washington). These multi-temporal DSMs are required on the one hand to determine the three-dimensional surface deformations and on the other hand it will be required for differential correction for orthophoto production. Drawing on the example of the acquired data at the Super-Sauze landslide, we demonstrate the potential but also the limitations of the photogrammetric point clouds. To determine the quality of the photogrammetric point cloud, these point clouds are compared with the TLS-based DSMs. The comparison shows that photogrammetric points accuracies are in the range of cm to dm, therefore don't reach the quality of the high-resolution TLS-based DSMs. Further, the validation of the photogrammetric point clouds reveals that some of them have internal curvature effects. The advantage of the photogrammetric 3D data acquisition is the use of low-cost equipment and less time-consuming data collection in the field. While the accuracy of the photogrammetric point clouds is not as high as TLS-based DSMs, the advantages of the former method are seen when applied in areas where dm-range is sufficient.

  11. Optimisation techniques in vaginal cuff brachytherapy.

    PubMed

    Tuncel, N; Garipagaoglu, M; Kizildag, A U; Andic, F; Toy, A

    2009-11-01

    The aim of this study was to explore whether an in-house dosimetry protocol and optimisation method are able to produce a homogeneous dose distribution in the target volume, and how often optimisation is required in vaginal cuff brachytherapy. Treatment planning was carried out for 109 fractions in 33 patients who underwent high dose rate iridium-192 (Ir(192)) brachytherapy using Fletcher ovoids. Dose prescription and normalisation were performed to catheter-oriented lateral dose points (dps) within a range of 90-110% of the prescribed dose. The in-house vaginal apex point (Vk), alternative vaginal apex point (Vk'), International Commission on Radiation Units and Measurements (ICRU) rectal point (Rg) and bladder point (Bl) doses were calculated. Time-position optimisations were made considering dps, Vk and Rg doses. Keeping the Vk dose higher than 95% and the Rg dose less than 85% of the prescribed dose was intended. Target dose homogeneity, optimisation frequency and the relationship between prescribed dose, Vk, Vk', Rg and ovoid diameter were investigated. The mean target dose was 99+/-7.4% of the prescription dose. Optimisation was required in 92 out of 109 (83%) fractions. Ovoid diameter had a significant effect on Rg (p = 0.002), Vk (p = 0.018), Vk' (p = 0.034), minimum dps (p = 0.021) and maximum dps (p<0.001). Rg, Vk and Vk' doses with 2.5 cm diameter ovoids were significantly higher than with 2 cm and 1.5 cm ovoids. Catheter-oriented dose point normalisation provided a homogeneous dose distribution with a 99+/-7.4% mean dose within the target volume, requiring time-position optimisation.

  12. a Fast and Flexible Method for Meta-Map Building for Icp Based Slam

    NASA Astrophysics Data System (ADS)

    Kurian, A.; Morin, K. W.

    2016-06-01

    Recent developments in LiDAR sensors make mobile mapping fast and cost effective. These sensors generate a large amount of data which in turn improves the coverage and details of the map. Due to the limited range of the sensor, one has to collect a series of scans to build the entire map of the environment. If we have good GNSS coverage, building a map is a well addressed problem. But in an indoor environment, we have limited GNSS reception and an inertial solution, if available, can quickly diverge. In such situations, simultaneous localization and mapping (SLAM) is used to generate a navigation solution and map concurrently. SLAM using point clouds possesses a number of computational challenges even with modern hardware due to the shear amount of data. In this paper, we propose two strategies for minimizing the cost of computation and storage when a 3D point cloud is used for navigation and real-time map building. We have used the 3D point cloud generated by Leica Geosystems's Pegasus Backpack which is equipped with Velodyne VLP-16 LiDARs scanners. To improve the speed of the conventional iterative closest point (ICP) algorithm, we propose a point cloud sub-sampling strategy which does not throw away any key features and yet significantly reduces the number of points that needs to be processed and stored. In order to speed up the correspondence finding step, a dual kd-tree and circular buffer architecture is proposed. We have shown that the proposed method can run in real time and has excellent navigation accuracy characteristics.

  13. Method of forming pointed structures

    NASA Technical Reports Server (NTRS)

    Pugel, Diane E. (Inventor)

    2011-01-01

    A method of forming an array of pointed structures comprises depositing a ferrofluid on a substrate, applying a magnetic field to the ferrofluid to generate an array of surface protrusions, and solidifying the surface protrusions to form the array of pointed structures. The pointed structures may have a tip radius ranging from approximately 10 nm to approximately 25 micron. Solidifying the surface protrusions may be carried out at a temperature ranging from approximately 10 degrees C. to approximately 30 degrees C.

  14. Tracking capabilities of SPADs for laser ranging

    NASA Technical Reports Server (NTRS)

    Zappa, F.; Ripamonti, Giancarlo; Lacaita, A.; Cova, Sergio; Samori, C.

    1993-01-01

    The spatial sensitivity of Single-Photon Avalanche Diodes (SPADs) can be exploited in laser ranging measurements to finely tune the laser spot in the center of the detector sensitive area. We report the performance of a SPAD with l00 micron diameter. It features a time resolution better than 80 ps rms when operated 4V above V(b) at minus 30 C, and a spatial sensitivity better than 20 microns to radial displacements of the laser spot. New SPAD structures with auxiliary delay detectors are proposed. These improved devices could allow a two dimensional sensitivity, that could be employed for the design of pointing servos.

  15. Cognitive Function in a Randomized Trial of Evolocumab.

    PubMed

    Giugliano, Robert P; Mach, François; Zavitz, Kenton; Kurtz, Christopher; Im, Kyungah; Kanevsky, Estella; Schneider, Jingjing; Wang, Huei; Keech, Anthony; Pedersen, Terje R; Sabatine, Marc S; Sever, Peter S; Robinson, Jennifer G; Honarpour, Narimon; Wasserman, Scott M; Ott, Brian R

    2017-08-17

    Background Findings from clinical trials of proprotein convertase subtilisin-kexin type 9 (PCSK9) inhibitors have led to concern that these drugs or the low levels of low-density lipoprotein (LDL) cholesterol that result from their use are associated with cognitive deficits. Methods In a subgroup of patients from a randomized, placebo-controlled trial of evolocumab added to statin therapy, we prospectively assessed cognitive function using the Cambridge Neuropsychological Test Automated Battery. The primary end point was the score on the spatial working memory strategy index of executive function (scores range from 4 to 28, with lower scores indicating a more efficient use of strategy and planning). Secondary end points were the scores for working memory (scores range from 0 to 279, with lower scores indicating fewer errors), episodic memory (scores range from 0 to 70, with lower scores indicating fewer errors), and psychomotor speed (scores range from 100 to 5100 msec, with faster times representing better performance). Assessments of cognitive function were performed at baseline, week 24, yearly, and at the end of the trial. The primary analysis was a noninferiority comparison of the mean change from baseline in the score on the spatial working memory strategy index of executive function between the patients who received evolocumab and those who received placebo; the noninferiority margin was set at 20% of the standard deviation of the score in the placebo group. Results A total of 1204 patients were followed for a median of 19 months; the mean (±SD) change from baseline over time in the raw score for the spatial working memory strategy index of executive function (primary end point) was -0.21±2.62 in the evolocumab group and -0.29±2.81 in the placebo group (P<0.001 for noninferiority; P=0.85 for superiority). There were no significant between-group differences in the secondary end points of scores for working memory (change in raw score, -0.52 in the evolocumab group and -0.93 in the placebo group), episodic memory (change in raw score, -1.53 and -1.53, respectively), or psychomotor speed (change in raw score, 5.2 msec and 0.9 msec, respectively). In an exploratory analysis, there were no associations between LDL cholesterol levels and cognitive changes. Conclusions In a randomized trial involving patients who received either evolocumab or placebo in addition to statin therapy, no significant between-group difference in cognitive function was observed over a median of 19 months. (Funded by Amgen; EBBINGHAUS ClinicalTrials.gov number, NCT02207634 .).

  16. Quercus suber range dynamics by ecological niche modelling: from the Last Interglacial to present time

    NASA Astrophysics Data System (ADS)

    Vessella, Federico; Simeone, Marco Cosimo; Schirone, Bartolomeo

    2015-07-01

    Ecological Niche Modelling (ENM) is widely used to depict species potential occurrence according to environmental variables under different climatic scenarios. We tested the ENM approach to infer past range dynamics of cork oak, a keystone species of the Mediterranean Biome, from 130 ka to the present time. Hindcasting implications would deal with a better species risk assessment and conservation management for the future. We modelled present and past occurrence of cork oak using seven ENM algorithms, starting from 63,733 spatially unique presence points at 30 arc-second resolution. Fourteen environmental variables were used and four time slices were considered (Last Interglacial, Last Glacial Maximum, mid-Holocene and present time). A threshold-independent evaluation of the goodness-of-fit of the models was evaluated by means of ROC curve and fossil or historical evidences were used to validate the results. Four weighted average maps depicted the dynamics of area suitability for cork oak in the last 130 ka. The derived species autoecology allowed its long-term occurrence in the Mediterranean without striking range reduction or shifting. Fossil and historical post-processing validation support the modelled past spatial extension and a neglected species presence at Levantine until the recent time. Despite the severe climatic oscillation since the Last Glacial Maximum, cork oak potential distribution area experienced limited range changes, confirming its strong link with the Mediterranean Basin. The ecological amplitude of Quercus suber could be therefore adopted as a reference to trace the Mediterranean bioclimate area. A better knowledge of the past events of Mediterranean vegetation, a wider range of study species and environmental determinants are essential to inform us about its current state, its sensitivity to human impact and the potential responses to future changes.

  17. Static and sliding contact of rough surfaces: Effect of asperity-scale properties and long-range elastic interactions

    NASA Astrophysics Data System (ADS)

    Hulikal, Srivatsan; Lapusta, Nadia; Bhattacharya, Kaushik

    2018-07-01

    Friction in static and sliding contact of rough surfaces is important in numerous physical phenomena. We seek to understand macroscopically observed static and sliding contact behavior as the collective response of a large number of microscopic asperities. To that end, we build on Hulikal et al. (2015) and develop an efficient numerical framework that can be used to investigate how the macroscopic response of multiple frictional contacts depends on long-range elastic interactions, different constitutive assumptions about the deforming contacts and their local shear resistance, and surface roughness. We approximate the contact between two rough surfaces as that between a regular array of discrete deformable elements attached to a elastic block and a rigid rough surface. The deformable elements are viscoelastic or elasto/viscoplastic with a range of relaxation times, and the elastic interaction between contacts is long-range. We find that the model reproduces the main macroscopic features of evolution of contact and friction for a range of constitutive models of the elements, suggesting that macroscopic frictional response is robust with respect to the microscopic behavior. Viscoelasticity/viscoplasticity contributes to the increase of friction with contact time and leads to a subtle history dependence. Interestingly, long-range elastic interactions only change the results quantitatively compared to the meanfield response. The developed numerical framework can be used to study how specific observed macroscopic behavior depends on the microscale assumptions. For example, we find that sustained increase in the static friction coefficient during long hold times suggests viscoelastic response of the underlying material with multiple relaxation time scales. We also find that the experimentally observed proportionality of the direct effect in velocity jump experiments to the logarithm of the velocity jump points to a complex material-dependent shear resistance at the microscale.

  18. Establishment of reference scores and interquartile ranges for the Japanese Orthopaedic Association Back Pain Evaluation Questionnaire (JOABPEQ) in patients with low back pain.

    PubMed

    Tominaga, Ryoji; Sekiguchi, Miho; Yonemoto, Koji; Kakuma, Tatsuyuki; Konno, Shin-Ichi

    2018-05-01

    The Japanese Orthopaedic Association Back Pain Evaluation Questionnaire (JOABPEQ) was developed in 2007, including the five domains of Pain-related disorder, Lumbar spine dysfunction, Gait disturbance, Social life disturbance, and Psychological disorder. It is used by physicians to evaluate treatment efficacy by comparing scores before and after treatment. However, the JOABPEQ does not allow evaluation of the severity of a patient's condition compared to the general population at a single time point. Given the unavailability of a standard measurement of back pain, we sought to establish reference scores and interquartile ranges using data obtained from a multicenter, cross-sectional survey taken in Japanese primary care settings. The Lumbar Spinal Stenosis Diagnosis Support Tool project was conducted from 2011 to 2012 in 1657 hospitals in Japan to investigate the establishment of reference scores using JOABPEQ. Patients aged ≥ 20 years undergoing medical examinations by either non-orthopaedic primary care physicians or general orthopedists were considered for enrollment. A total of 10,651 consecutive low back pain patients (5331 men, 5320 women, 18 subjects with missing sex data) who had undergone a medical examination were included. Reference scores and interquartile ranges for each of the five domains of the JOABPEQ according to age and sex were recorded. The median score and interquartile range are the same in the domain of Pain-related disorder in all ages and sexes. The reference scores for Gait disturbance, Social life disturbance and Psychological disorder declined with increasing age in both age- and sex-stratified groups, while there was some different trend in Lumbar spine dysfunction between men and women. Reference scores and interquartile ranges for JOABPEQ were generated based on the data from the examination data. These provide a measurement standard to assess patient perceptions of low back pain at any time point during evaluation or therapy. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Influence of time point of calibration on accuracy of continuous glucose monitoring in individuals with type 1 diabetes.

    PubMed

    Zueger, Thomas; Diem, Peter; Mougiakakou, Stavroula; Stettler, Christoph

    2012-07-01

    Data on the influence of calibration on accuracy of continuous glucose monitoring (CGM) are scarce. The aim of the present study was to investigate whether the time point of calibration has an influence on sensor accuracy and whether this effect differs according to glycemic level. Two CGM sensors were inserted simultaneously in the abdomen on either side of 20 individuals with type 1 diabetes. One sensor was calibrated predominantly using preprandial glucose (calibration(PRE)). The other sensor was calibrated predominantly using postprandial glucose (calibration(POST)). At minimum three additional glucose values per day were obtained for analysis of accuracy. Sensor readings were divided into four categories according to the glycemic range of the reference values (low, ≤4 mmol/L; euglycemic, 4.1-7 mmol/L; hyperglycemic I, 7.1-14 mmol/L; and hyperglycemic II, >14 mmol/L). The overall mean±SEM absolute relative difference (MARD) between capillary reference values and sensor readings was 18.3±0.8% for calibration(PRE) and 21.9±1.2% for calibration(POST) (P<0.001). MARD according to glycemic range was 47.4±6.5% (low), 17.4±1.3% (euglycemic), 15.0±0.8% (hyperglycemic I), and 17.7±1.9% (hyperglycemic II) for calibration(PRE) and 67.5±9.5% (low), 24.2±1.8% (euglycemic), 15.5±0.9% (hyperglycemic I), and 15.3±1.9% (hyperglycemic II) for calibration(POST). In the low and euglycemic ranges MARD was significantly lower in calibration(PRE) compared with calibration(POST) (P=0.007 and P<0.001, respectively). Sensor calibration predominantly based on preprandial glucose resulted in a significantly higher overall sensor accuracy compared with a predominantly postprandial calibration. The difference was most pronounced in the hypo- and euglycemic reference range, whereas both calibration patterns were comparable in the hyperglycemic range.

  20. Effects of Temperature on the Performance and Stability of Recent COTS Silicon Oscillators

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Hammoud, Ahmad

    2010-01-01

    Silicon oscillators have lately emerged to serve as potential replacement for crystal and ceramic resonators to provide timing and clock signals in electronic systems. These semiconductor-based devices, including those that are based on MEMS technology, are reported to be resistant to vibration and shock (an important criteria for systems to be deployed in space), immune to EMI, consume very low current, require few or no external components, and cover a wide range of frequency for analog and digital circuits. In this work, the performance of five recently-developed COTS silicon oscillator chips from different manufacturers was determined within a temperature range that extended beyond the individual specified range of operation. In addition, restart capability at extreme temperatures, i.e. power switched on while the device was soaking at extreme (hot or cold) temperature, and the effects of thermal cycling under a wide temperature range on the operation of these silicon oscillators were also investigated. Performance characterization of each oscillator was obtained in terms of its output frequency, duty cycle, rise and fall times, and supply current at specific test temperatures. The five different oscillators tested operated beyond their specified temperature region, with some displaying excellent stability throughout the whole test temperature range. Others experienced some instability at certain temperature test points as evidenced by fluctuation in the output frequency. Recovery from temperature-induced changes took place when excessive temperatures were removed. It should also be pointed out that all oscillators were able to restart at the extreme test temperatures and to withstand the limited thermal cycling without undergoing any significant changes in their characteristics. In addition, no physical damage was observed in the packaging material of any of these silicon oscillators due to extreme temperature exposure and thermal cycling. It is recommended that additional and more comprehensive testing under long term cycling be carried out to fully establish the reliability of these devices and to determine their suitability for use in space exploration missions under extreme temperature conditions.

Top