Heath, Robert R; Vazquez, Aime; Schnell, Elena Q; Villareal, Janett; Kendra, Paul E; Epsky, Nancy D
2009-12-01
Several species of Anastrepha and Bactrocera fruit flies (Diptera: Tephritidae) are captured in traps baited with the protein bait NuLure combined with borax (sodium tetraborate decahydrate) in an aqueous solution, typically 9% NuLure (vol:vol) with 3% borax (wt:vol). NuLure is an acid hydrolysate of corn and has an acidic pH. Addition of borax makes the solution more alkaline, and increase in alkalinity results in increase of ammonia release from the bait solution. This is a very dynamic system, with resultant pH affected by factors such as the amount of borax added, the pH of the water used for preparation, the age of the bait solution, and the development of microbial growth. Problems with borax include amount needed to increase alkalinity of NuLure solutions, which creates difficulties in disposing of spent bait in fruit fly trapping programs. Therefore, research was conducted to evaluate NaOH as an alternative method to increase alkalinity of NuLure solutions. Laboratory experiments compared effect of NaOH versus borax for pH modification on changes in pH and ammonia content of NuLure solutions over time. Although NuLure/NaOH solutions could be adjusted to a more alkaline pH than NuLure/borax solutions, borax plays a critical role in pH stability over time. However, the pH of NuLure/NaOH is stabilized when propylene glycol (10% vol:vol) was used to prepare the bait solution. The use of NaOH can provide an alternative to the use of borax to increase bait solution alkalinity.
Method for producing rapid pH changes
Clark, John H.; Campillo, Anthony J.; Shapiro, Stanley L.; Winn, Kenneth R.
1981-01-01
A method of initiating a rapid pH change in a solution by irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.
Method for producing rapid pH changes
Clark, J.H.; Campillo, A.J.; Shapiro, S.L.; Winn, K.R.
A method of initiating a rapid pH change in a solution comprises irradiating the solution with an intense flux of electromagnetic radiation of a frequency which produces a substantial pK change to a compound in solution. To optimize the resulting pH change, the compound being irradiated in solution should have an excited state lifetime substantially longer than the time required to establish an excited state acid-base equilibrium in the solution. Desired pH changes can be accomplished in nanoseconds or less by means of picosecond pulses of laser radiation.
Influence of the dentinal wall on the pH of sodium hypochlorite during root canal irrigation.
Macedo, Ricardo Gomes; Herrero, Noemi Pascual; Wesselink, Paul; Versluis, Michel; van der Sluis, Luc
2014-07-01
The purpose of this study was to evaluate the influence of dentin on the pH levels of different concentrations of sodium hypochlorite (NaOCl) solutions over time and to evaluate if preconditioning of dentin with 17% EDTA or agitation of the NaOCl solution influences these pH levels. A novel clinically representative model that scales with the ratio of the irrigant volume to the dentin surface area of a human root canal was used. Three standardized bovine dentin bars (2 × 2 × 10 mm) were placed in a plastic test tube. A total of 150 tubes were distributed in 29 groups. In the first experiment, the pH of various NaOCl solutions, with different concentrations (3%, 6%, and 9%) and starting pH levels (5 and 12), was monitored during exposure to dentin between 10 and 300 seconds. In a second experiment, the effect of agitation (45 Hz) and pretreatment of dentin with 17% EDTA on the pH levels of various NaOCl solutions was studied after 30 seconds of exposure to dentin. The short-term chemical stability of the tested solutions was assessed for both the concentration and the pH. The exposure time (P < .001) and concentration of the NaOCl solution (P < .011) significantly influence the pH level after exposure to dentin. However, the change in pH is too small to induce a change in the irrigant antimicrobial/tissue dissolution capacity. Agitation of the irrigant and preconditioning of the dentin did not alter the pH (P > .05). Both the pH 5 and pH 12 solutions were chemically stable for 1 hour. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Rozalen, Marisa; Ramos, M. Elena; Huertas, F. Javier; Fiore, Saverio; Gervilla, Fernando
2013-11-01
The effect of citrate and oxalate on tremolite dissolution rate was measured at 37 °C in non-stirred flow-through reactors, using modified Gamble's solutions at pH 4 (macrophages), 7.4 (interstitial fluids) and 5.5 (intermediate check point) containing 0, 0.15, 1.5 and 15 mmol L-1 of citrate or oxalate. The dissolution rates calculated from Si concentration in the output solutions without organic ligands depend on pH, decreasing when the pH increases from -13.00 (pH 4) to -13.35 (pH 7.4) mol g-1 s-1 and following a proton-promoted mechanism. The presence of both ligands enhances dissolution rates at every pH, increasing this effect when the ligand concentration increases. Citrate produces a stronger effect as a catalyst than oxalate, mainly at more acidic pHs and enhances dissolution rates until 20 times for solutions with 15 mmol L-1 citrate. However, at pH 7.4 the effect is lighter and oxalate solutions (15 mmol L-1) only enhances dissolution rates eight times respect to free organic ligand solutions. Dissolution is promoted by the attack to protons and organic ligands to the tremolite surface. Magnesium speciation in oxalate and citrate solutions shows that Mg citrate complexes are more effective than oxalate ones during the alteration of tremolite in magrophages, but this tendency is the opposite for interstitial fluids, being oxalate magnesium complexes stronger. The biodurability estimations show that the destruction of the fibers is faster in acidic conditions (macrophages) than in the neutral solutions (interstitial fluid). At pH 4, both ligands oxalate and citrate reduce the residence time of the fibers with respect to that calculated in absence of ligands. Nevertheless, at pH 7.4 the presence of ligands does not reduce significantly the lifetime of the fibers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, N.S.K.
In aqueous lysine-sucrose model systems, the effects of reaction time, pH and molar ratio were studied on the formation of non-enzymatic browning reaction (NBR) products. The extent of sucrose hydrolysis was measured and the antioxidant effect of NBR products on linoleic acid emulsions was examined. Nuclear magnetic resonance (NMR) spectra were obtained at various stages of browning. Sucrose produced NMR produces with lysine in an aqueous system at 100/sup 0/C. The C-13 NMR spectra indicated that the NBR started when sucrose and lysine were dissolved in water. The C-13 NMR spectra also showed that heating did not have an effectmore » on the gross composition of polymeric species. The absorbance at 480 nm of 0.75 M lysine-sucrose solution heated up to 6 hours increased with reaction times. The pH values of heated lysine-sucrose solution gradually decreased with reaction time. When 0.75 M sucrose or lysine solution was heated separately up to 6 hours, there were no changes in absorbance in pH. In the pH range of 3.52-6.35, higher absorbance was obtained from heated lysine-sucrose solution at acidic pH levels than at neutral pH levels. As the concentration of lysine and sucrose solution was increased, the absorbance increased. At longer reaction times or acidic pH levels, enhanced hydrolysis of sucrose to reducing sugars resulted in more NBR products. NBR products obtained at a longer reaction time, an acidic pH, and higher concentration of reactants showed a darker brown color and were effective in preventing the formation of peroxides. The oxygen uptake of linoleic acid emulsion having NBR products was smaller than that of linoleic acid emulsion without NBR products. Based on these results, it was concluded that sucrose may act as an antioxidant in processed foods containing both amino acids and lipids.« less
Liu, Xianli; Xu, Dong; Wu, Feng; Liao, Zhenhuan; Liu, Jiantong; Deng, Nansheng
2004-03-01
Under a high-pressure mercury lamp (HPML) and using an exposure time of 4 h, the photoproduction of hydroxyl radicals (*OH) could be induced in an aqueous solution containing humic acid (HA). Hydroxyl radicals were determined by high-performance liquid chromatography using benzene as a probe. The results showed that *OH photoproduction increased from 1.80 to 2.74 microM by increasing the HA concentration from 10 to 40 mg L(-1) at an exposure time of 4 h (pH 6.5). Hydroxyl radical photoproduction in aqueous solutions of HA containing algae was greater than that in the aqueous solutions of HA without algae. The photoproduction of *OH in the HA solution with Fe(III) was greater than that of the solution without Fe(III) at pH ranging from 4.0 to 8.0. The photoproduction of *OH in HA solution with algae with or without Fe(III) under a 250 W HPML was greater than that under a 125 W HPML. The photoproduction of *OH in irradiated samples was influenced by the pH. The results showed that HPML exposure for 4 h in the 4-8 pH range led to the highest *OH photoproduction at pH 4.0.
Stability of Adrenaline in Irrigating Solution for Intraocular Surgery.
Shibata, Yuuka; Kimura, Yasuhiro; Taogoshi, Takanori; Matsuo, Hiroaki; Kihira, Kenji
2016-01-01
Intraocular irrigating solution containing 1 µg/mL adrenaline is widely used during cataract surgery to maintain pupil dilation. Prepared intraocular irrigating solutions are recommended for use within 6 h. After the irrigating solution is admistered for dilution, the adrenaline may become oxidized, and this may result in a decrease in its biological activity. However, the stability of adrenaline in intraocular irrigating solution is not fully understood. The aim of this study was to evaluate the stability of adrenaline in clinically used irrigating solutions of varying pH. Six hours after mixing, the adrenaline percentages remaining were 90.6%±3.7 (pH 7.2), 91.1%±2.2 (pH 7.5), and 65.2%±2.8 (pH 8.0) of the initial concentration. One hour after mixing, the percentages remaining were 97.6%±2.0 (pH 7.2), 97.4%±2.7 (pH 7.5), and 95.6%±3.3 (pH 8.0). The degradation was especially remarkable and time dependent in the solution at pH 8.0. These results indicate that the concentration of adrenaline is decreased after preparation. Moreover, we investigated the influence of sodium bisulfite on adrenaline stability in irrigating solution. The percentage adrenaline remaining at 6 h after mixing in irrigating solution (pH 8.0) containing sodium bisulfite at 0.5 µg/mL (concentration in irrigating solution) or at 500 µg/mL (concentration in the undiluted adrenaline preparation) were 57.5 and 97.3%, respectively. Therefore, the low concentration of sodium bisulfite in the irrigating solution may be a cause of the adrenaline loss. In conclusion, intraocular irrigation solution with adrenaline should be prepared just prior to its use in surgery.
Leonardo, Natália Gomes e Silva; Carlotto, Israel Bangel; Luisi, Simone Bonato; Kopper, Patrícia Maria Poli; Grecca, Fabiana Soares; Montagner, Francisco
2016-04-01
The aim of this study was to evaluate the pH and the available chlorine content from sodium hypochlorite (NaOCl) and calcium hypochlorite (Ca[OCl]2) solutions stored in different conditions and time periods and the surface tension of Ca(OCl)2 solutions in comparison with NaOCl. Solutions at 0.5%, 1%, 2.5%, and 5.25% concentrations were prepared. The pH level and the available chlorine content of freshly prepared solutions and solutions stored for 30, 60, and 90 days at 25°C, 4°C, or 37°C were evaluated in a digital pH meter and by titration, respectively. Surface tension was tested using a Du Nouy tensiometer (Sigma 702, Force Tensiometer; Attension, Espoo, Finland). Descriptive and inferential statistical analyses were performed. A precipitate formed by 2.5% and 5.25% Ca(OCl)2 solutions was observed. Ca(OCl)2 showed a higher concentration of available chlorine than NaOCl. Both 2.5% and 5.25% NaOCl and Ca(OCl)2 had a decrease in the available chlorine content when compared with freshly prepared solutions; 0.5% and 1% NaOCl tend to have a lower pH compared with 0.5% and 1% Ca(OCl)2. NaOCl, 5.25%, showed higher pH compared with 5.25% Ca(OCl)2. NaOCl and Ca(OCl)2 in 0.5% and 1% concentrations tend to show a reduced pH level, whereas 2.5% and 5.25% solutions showed an increase in pH. The heat contributed to the instability of the solutions. NaOCl showed lower surface tension values than Ca(OCl)2. Ca(OCl)2 solutions are extremely alkaline and tend to have more available chlorine content than NaOCl but have a higher surface tension than NaOCl. Regarding the available chlorine content, these solutions tend to be stable to 30 days of storage when kept at 4°C or at 25°C. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Optimization of Photooxidative Removal of Phenazopyridine from Water
NASA Astrophysics Data System (ADS)
Saeid, Soudabeh; Behnajady, Mohammad A.; Tolvanen, Pasi; Salmi, Tapio
2018-05-01
The photooxidative removal of analgesic pharmaceutical compound phenazopyridine (PhP) from aqueous solutions by UV/H2O2 system with a re-circulated photoreactor was investigated. Response surface methodology (RSM) was employed to optimize the effect of operational parameters on the photooxidative removal efficiency. The investigated variables were: the initial PhP and H2O2 concentrations, irradiation time, volume of solution and pH. The analysis of variance (ANOVA) of quadratic model demonstrated that the described model was highly significant. The predicted values of the photooxidative removal efficiency were found to be in a fair agreement with experimental values ( R 2 = 0.9832, adjusted R 2 = 0.9716). The model predicted that the optimal reaction conditions for a maximum removal of PhP (>98%) were: initial PhP concentration less than 23 mg L-1, initial concentration of H2O2 higher than 470 mg L-1, solution volume less than 500 mL, pH close to 2 and irradiation time longer than 6 min.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casella, Amanda J.; Hylden, Laura R.; Campbell, Emily L.
Knowledge of real-time solution properties and composition is a necessity for any spent nuclear fuel reprocessing method. Metal-ligand speciation in aqueous solutions derived from the dissolved commercial spent fuel is highly dependent upon the acid concentration/pH, which influences extraction efficiency and the resulting speciation in the organic phase. Spectroscopic process monitoring capabilities, incorporated in a counter current centrifugal contactor bank, provide a pathway for on-line real-time measurement of solution pH. The spectroscopic techniques are process-friendly and can be easily configured for on-line applications, while classic potentiometric pH measurements require frequent calibration/maintenance and have poor long-term stability in aggressive chemical andmore » radiation environments. Our research is focused on developing a general method for on-line determination of pH of aqueous solutions through chemometric analysis of Raman spectra. Interpretive quantitative models have been developed and validated under the range of chemical composition and pH using a lactic acid/lactate buffer system. The developed model was applied to spectra obtained on-line during solvent extractions performed in a centrifugal contactor bank. The model predicted the pH within 11% for pH > 2, thus demonstrating that this technique could provide the capability of monitoring pH on-line in applications such as nuclear fuel reprocessing.« less
Oztop, Mecit H; Rosenberg, Moshe; Rosenberg, Yael; McCarthy, Kathryn L; McCarthy, Michael J
2010-10-01
Effective means for controlled delivery of nutrients and nutraceuticals are needed. Whey protein-based gels, as a model system and as a potential delivery system, exhibit pH-dependent swelling when placed in aqueous solutions. Understanding the physics that govern gel swelling is thus important when designing gel-based delivery platforms. The extent of swelling over time was monitored gravimetrically. In addition to gravimetric measurements, magnetic resonance imaging (MRI) a real-time noninvasive imaging technique that quantified changes in geometry and water content of these gels was utilized. Heat-set whey protein gels were prepared at pH 7 and swelling was monitored in aqueous solutions with pH values of 2.5, 7, and 10. Changes in dimension over time, as characterized by the number of voxels in an image, were correlated to gravimetric measurements. Excellent correlations between mass uptake and volume change (R(2)= 0.99) were obtained for the gels in aqueous solutions at pH 7 and 10, but not for gels in the aqueous solution at pH 2.5. To provide insight into the mechanisms for water uptake, nuclear magnetic resonance (NMR) relaxation times were measured in independent experiments. The relaxation spectrum for the spin-spin relaxation time (T(2)) showed the presence of 3 proton pools for pH 7 and 10 trials and 4 proton pools for pH 2.5 trials. Results demonstrate that MRI and NMR relaxation measurements provided information about swelling in whey protein gels that can constitute a new means for investigating and developing effective delivery systems for foods.
Kubáň, Pavel; Boček, Petr
2015-06-12
Fundamental operational principle and instrumental set-up of electromembrane extraction (EME) suggest that electrolysis may play an important role in this recently developed micro-extraction technique. In the present study, the effect of electrolysis in EME is described comprehensively for the first time and it is demonstrated that electrolysis considerably influences EME performance. Micro-electromembrane extraction (μ-EME) across free liquid membrane formed by 1-pentanol was utilized for real-time monitoring of the electrolytically induced changes in composition of μ-EME solutions. These changes were visualized with a set of acid-base indicators. Changes in colours of their aqueous solutions revealed serious variations in their pH values, which occurred within seconds to minutes of the μ-EME process. Variations of up to eight pH units were observed for indicator solutions initially prepared in 1, 5 and 10mM hydrochloric acid. No or only negligible pH changes (less than 0.15 pH unit) were observed for indicator solutions prepared in 50 and 100mM acetic acid demonstrating that initial composition of the aqueous solutions was the crucial parameter. These results were also confirmed by theoretical calculations of maximum pH variations in the solutions, which were based on total electric charge transfers measured in the μ-EME systems, and by exact measurements of their pH values after μ-EMEs. Acceptor solutions that, in the current practice, consist predominantly of low concentrations of strong mineral acids or alkali hydroxides may thus not always ensure adequate EME performance, which was manifested by decrease in extraction recoveries of a basic drug papaverine. A suitable remedy to the observed effects is the application of acceptor solutions containing high concentrations of weak acids or bases. These solutions not only eliminate the decrease in recoveries but also serve well as matrices of extracted samples for subsequent analysis by capillary electrophoresis. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Antoni, Herianto, Jason Ghorman; Anastasia, Evelin; Hardjito, Djwantoro
2017-09-01
Fly ash with high calcium oxide content when used as the base material in geopolymer concrete could cause flash setting or rapid hardening. However, it might increase the compressive strength of geopolymer concrete. This rapid hardening could cause problems if the geopolymer concrete is used on a large scale casting that requires a long setting time. CaO content can be indicated by pH values of the fly ash, while higher pH is correlated with the rapid setting time of fly ash-based geopolymer. This study investigates the addition of acid solution to reduce the initial pH of the fly ash and to prolong the setting time of the mixture. The acids used in this study are hydrochloric acid (HCl), sulfuric acid (H2 SO4), nitric acid (HNO3) and acetic acid (CH3 COOH). It was found that the addition of acid solution in fly ash was able to decrease the initial pH of fly ash, however, the initial setting time of geopolymer was not reduced. It was even faster than that of the control mixture. The acid type causes various influence, depending on the fly ash properties. In addition, the use of acid solution in fly ash reduces the compressive strength of geopolymer mortar. It is concluded that the addition of acid solution cannot prolong the rapid hardening of high calcium fly ash geopolymer, and it causes adverse effect on the compressive strength.
NASA Astrophysics Data System (ADS)
Sheikh, N.; Jalili, L.; Anvari, F.
2010-06-01
Poly(acrylic acid) (PAA) hydrogels were prepared by using electron beam (EB) crosslinking of PAA homopolymer from its aqueous solutions. The swelling behavior of the hydrogels was studied as a function of the concentration of PAA solution, radiation dose, pH of the swelling medium and swelling time. Also the environmental pH effect on the water diffusion mode into hydrogels was investigated. These hydrogels clearly showed pH-sensitive swelling behavior with Fickian type of diffusion in the stomach-like pH medium (pH 1.3) and non-Fickian type in the intestine-like pH medium (pH 6.8).
Ping, Jinglei; Blum, Jacquelyn E; Vishnubhotla, Ramya; Vrudhula, Amey; Naylor, Carl H; Gao, Zhaoli; Saven, Jeffery G; Johnson, Alan T Charlie
2017-08-01
Advances in techniques for monitoring pH in complex fluids can have a significant impact on analytical and biomedical applications. This study develops flexible graphene microelectrodes (GEs) for rapid (<5 s), very-low-power (femtowatt) detection of the pH of complex biofluids by measuring real-time Faradaic charge transfer between the GE and a solution at zero electrical bias. For an idealized sample of phosphate buffer solution (PBS), the Faradaic current is varied monotonically and systematically with the pH, with a resolution of ≈0.2 pH unit. The current-pH dependence is well described by a hybrid analytical-computational model, where the electric double layer derives from an intrinsic, pH-independent (positive) charge associated with the graphene-water interface and ionizable (negative) charged groups. For ferritin solution, the relative Faradaic current, defined as the difference between the measured current response and a baseline response due to PBS, shows a strong signal associated with ferritin disassembly and the release of ferric ions at pH ≈2.0. For samples of human serum, the Faradaic current shows a reproducible rapid (<20 s) response to pH. By combining the Faradaic current and real-time current variation, the methodology is potentially suitable for use to detect tumor-induced changes in extracellular pH. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hondrum, S O; Ezell, J H
1996-01-01
pH affects the efficacy of local anesthetics by determining the percentage of the lipid-soluble base form of the anesthetic available for diffusion and penetration of the nerve sheath. The purpose of this study was to determine the relationship between pH and the concentrations of antioxidant and vasoconstrictor in dental local anesthetic solutions over real-time and after accelerated aging. Several batches of lidocaine and mepivacaine with vasoconstrictors were tested. Results showed that, immediately upon receipt from the manufacturers, three batches were below the USP pH limit (pH 3.3), and two batches contained less than the minimum limit of vasoconstrictors (90%). Real-time tests on batches that were within normal limits revealed that solutions were stable past 4 yr. Accelerated aging tests revealed a strong correlation between a decrease in pH and loss of antioxidants and vasoconstrictors. In conclusion, a quality batch of local anesthetic should remain efficacious long past the manufacturer's stated shelf life; a batch that is less than optimal, or one that is exposed to environmental stresses, will degrade rapidly, and efficacy may be affected by decreases in pH and loss of vasoconstrictor. pH may be an inexpensive, readily available screening test for efficacy of local anesthetics.
Hondrum, S. O.; Ezell, J. H.
1996-01-01
pH affects the efficacy of local anesthetics by determining the percentage of the lipid-soluble base form of the anesthetic available for diffusion and penetration of the nerve sheath. The purpose of this study was to determine the relationship between pH and the concentrations of antioxidant and vasoconstrictor in dental local anesthetic solutions over real-time and after accelerated aging. Several batches of lidocaine and mepivacaine with vasoconstrictors were tested. Results showed that, immediately upon receipt from the manufacturers, three batches were below the USP pH limit (pH 3.3), and two batches contained less than the minimum limit of vasoconstrictors (90%). Real-time tests on batches that were within normal limits revealed that solutions were stable past 4 yr. Accelerated aging tests revealed a strong correlation between a decrease in pH and loss of antioxidants and vasoconstrictors. In conclusion, a quality batch of local anesthetic should remain efficacious long past the manufacturer's stated shelf life; a batch that is less than optimal, or one that is exposed to environmental stresses, will degrade rapidly, and efficacy may be affected by decreases in pH and loss of vasoconstrictor. pH may be an inexpensive, readily available screening test for efficacy of local anesthetics. PMID:10323112
Aging properties of films of plasticized vital wheat gluten cast from acidic and basic solutions.
Olabarrieta, Idoia; Cho, Sung-Woo; Gällstedt, Mikael; Sarasua, Jose-Ramon; Johansson, Eva; Hedenqvist, Mikael S
2006-05-01
In order to understand the mechanisms behind the undesired aging of films based on vital wheat gluten plasticized with glycerol, films cast from water/ethanol solutions were investigated. The effect of pH was studied by casting from solutions at pH 4 and pH 11. The films were aged for 120 days at 50% relative humidity and 23 degrees C, and the tensile properties and oxygen and water vapor permeabilities were measured as a function of aging time. The changes in the protein structure were determined by infrared spectroscopy and size-exclusion and reverse-phase high-performance liquid chromatography, and the film structure was revealed by optical and scanning electron microscopy. The pH 11 film was mechanically more stable with time than the pH 4 film, the latter being initially very ductile but turning brittle toward the end of the aging period. The protein solubility and infrared spectroscopy measurements indicated that the protein structure of the pH 4 film was initially significantly less polymerized/aggregated than that of the pH 11 film. The polymerization of the pH 4 film increased during storage but it did not reach the degree of aggregation of the pH 11 film. Reverse-phase chromatography indicated that the pH 11 films were to some extent deamidated and that this increased with aging. At the same time a large fraction of the aged pH 11 film was unaffected by reducing agents, suggesting that a time-induced isopeptide cross-linking had occurred. This isopeptide formation did not, however, change the overall degree of aggregation and consequently the mechanical properties of the film. During aging, the pH 4 films lost more mass than the pH 11 films mainly due to migration of glycerol but also due to some loss of volatile mass. Scanning electron and optical microscopy showed that the pH 11 film was more uniform in thickness and that the film structure was more homogeneous than that of the pH 4 film. The oxygen permeability was also lower for the pH 11 film. The fact that the pH 4 film experienced a larger and more rapid change in its mechanical properties with time than the pH 11 film, as a consequence of a greater loss of plasticizer, was presumably due to its initial lower degree of protein aggregation/polymerization. Consequently, the cross-link density achieved at pH 4 was too low to effectively retain volatiles and glycerol within the matrix.
Fabrication of Si nanopowder and application to hydrogen generation and photoluminescent material
NASA Astrophysics Data System (ADS)
Kobayashi, Yuki; Imamura, Kentaro; Matsumoto, Taketoshi; Kobayashi, Hikaru
2017-12-01
Si nanopowder is fabricated using the simple beads milling method. Fabricated Si nanopowder reacts with water in the neutral pH region between 7 and 9 to generate hydrogen. The hydrogen generation rate greatly increases with pH, while pH does not change after the hydrogen generation reaction. In the case of the reactions of Si nanopowder with strong alkaline solutions (eg pH13.9), 1600 mL hydrogen is generated from 1 g Si nanopowder in a short time (eg 15 min). When Si nanopowder is etched with HF solutions and immersed in ethanol, green photoluminescence (PL) is observed, and it is attributed to band-to-band transition of Si nanopowder. The Si nanopowder without HF etching in hexane shows blue PL. The PL spectra possess peaked structure, and it is attributed to vibronic bands of 9,10-dimethylantracene (DMA) in hexane solutions. The PL intensity is increased by more than 3,000 times by adsorption of DMA on Si nanopowder.
Park, Jin-Soo; Kim, Soon-Oh; Kim, Kyoung-Woong; Kim, Byung Ro; Moon, Seung-Hyeon
2003-04-04
A numerical analysis was undertaken for enhanced electrokinetic soil processing. To perform chemical conditioning of the electrode reservoirs, the electrokinetic soil process employed a membrane as a barrier between the electrode reservoirs and the contaminated soil. An alkaline solution was purged in the anode reservoir that was bounded by the membrane. A mathematical model was used for demonstration of pH change and phenol removal from a kaolinite soil bed, the prediction of pH variations in both electrode reservoirs, and the determination of an optimized injection time of the anode-purging solution. The time-dependent dispersion coefficient was employed in consideration of the averaging effect of the velocity profile on a one-dimensional transport. The estimation of pH and phenol profiles in the soil bed reasonably agreed with the experimental data. The simulation revealed that the removal efficiency of phenol from the kaolinite soil could be improved by maintaining pH of the anode solution.
Ultrasonication as a potential tool to predict solute crystallization in freeze-concentrates.
Ragoonanan, Vishard; Suryanarayanan, Raj
2014-06-01
We hypothesize that ultrasonication can accelerate solute crystallization in freeze-concentrates. Our objective is to demonstrate ultrasonication as a potential predictive tool for evaluating physical stability of excipients in frozen solutions. The crystallization tendencies of lyoprotectants (trehalose, sucrose), carboxylic acid buffers (citric, tartaric, malic, and acetic) and an amino acid buffer (histidine HCl) were studied. Aqueous solutions of buffers, lyoprotectants and mixtures of the two were cooled from room temperature to -20°C and sonicated to induce solute crystallization. The crystallized phases were identified by X-ray diffractometry (laboratory or synchrotron source). Sonication accelerated crystallization of trehalose dihydrate in frozen trehalose solutions. Sonication also enhanced solute crystallization in tartaric (200 mM; pH 5), citric (200 mM pH 4) and malic (200 mM; pH 4) acid buffers. At lower buffer concentrations, longer annealing times following sonication were required to facilitate solute crystallization. The time for crystallization of histidine HCl progressively increased as a function of sucrose concentration. The insonation period required to effect crystallization also increased with sucrose concentration. Sonication can substantially accelerate solute crystallization in the freeze-concentrate. Ultrasonication may be useful in assessing the crystallization tendency of formulation constituents used in long term frozen storage and freeze-drying.
Removal of Copper(II) Ions in Aqueous Solutions Using Tannin-Rich Plants as Natural Bio-Adsorbents
NASA Astrophysics Data System (ADS)
Paksamut, J.; Boonsong, P.
2018-03-01
In this study, the purpose of our interest is to investigatethe adsorption behavior of copper (II) ions in aqueous solution using some tannin-rich plants as natural bio-adsorbents such as mangosteen peels (Garciniamangostana L.), cassava leaves (Manihotesculenta Crantz) and Thai copper pod leaves (Sennasiamea (Lam.)) as powder form in different dosage of adsorbent plant materials.The adsorption capacities at different pH of solution and contact time were performed.All the experiments in this studywere chosen at room temperature by batch technique. From the experimental results showed that cassava leaves gave better adsorbent properties than mangosteen peels and Thai copper pod leaves. The increasing dosage of all adsorbents and contact time have been found to increase adsorption capacities. In this respect, the adsorption capacities depend crucially on the adsorbents and contact time. The optimum pH of copper (II) ions adsorption was pH4. According to this work, it was observed that bioadsorbent materials from tannin-rich plants could be used to remove copper (II) ions from aqueous solutions.
The dissolution of quartz in dilute aqueous solutions of organic acids at 25°C
Bennett, P.C.; Melcer, M.E.; Siegel, D.I.; Hassett, J.P.
1988-01-01
The dissolution of quartz in dilute aqueous solutions of organic acids at 25° and standard pressure was investigated by the batch dissolution method. The bulk dissolution rate of quartz in 20 mmole/Kg citrate solutions at pH 7 was 8 to 10 times faster than that in pure water. After 1750 hours the concentration of dissolved silica in the citrate solution was 167 μmole/Kg compared to 50 μmole/Kg in water and a 20 mmole/Kg solution of acetate at pH 7. Solutions of salicylic, oxalic, and humic acids also accelerated the dissolution of quartz in aqueous solution at pH 7. The rate of dissolution in organic acids decreased sharply with decreasing pH.The possibility of a silica-organic acid complex was investigated using UV-difference spectroscopy. Results suggest that dissolved silica is complexed by citrate, oxalate and pyruvate at pH 7 by an electron-donor acceptor complex, whereas no complexation occurs between silica and acetate, lactate, malonate, or succinate. Three models are proposed for the solution and surface complexation of silica by organic acid anions which result in the accelerated dissolution and increased solubility of quartz in organic rich water.
Irala, Luis Eduardo Duarte; Grazziotin-Soares, Renata; Salles, Alexandre Azevedo; Munari, Aline Zen; Pereira, Joseani Santos
2010-01-01
This in vitro study evaluated (1) the dissolution of bovine pulp tissue in solutions consisting of varying NaOCl concentrations and combined with EDTA; and (2) the pH of these solutions before and after the experiment. The independent variables were the concentration and the volume of the solution. Thirty bovine pulps were divided in equal fragments, resulting in 90 fragments of pulp tissue. Each fragment was immersed in one of the following solutions: 1% NaOCl (4 ml), 2.5% NaOCl (4 ml), 1% NaOCl + 17% EDTA (2 ml : 2 ml), 1% NaOCl + 17% EDTA (1 ml : 3 ml), 2.5% NaOCl + 17% EDTA (2 ml : 2 ml), and 2.5% NaOCl + 17% EDTA (1 ml : 3 ml). The test solutions were dichotomized as either able or not able to dissolve the tissue, the latter being attributed when the dissolution of the pulp tissue was not complete within 48 hours. When the samples were able to dissolve the tissue, the time required for complete tissue dissolution was submitted to statistical analysis. The pH of the solutions was measured before and after the experiment. The pH variable was dichotomized as either changed or unchanged. The results demonstrated that the NaOCl solutions combined with 17% EDTA were not able to dissolve the tissue. The t-test revealed that the 2.5% NaOCl solution presented a lower mean dissolution time than the 1% NaOCl solution (p < 0.001). The pH of the solutions with equal volumes of NaOCl and EDTA decreased in 48 hours.
Hale, C.J.
1983-11-15
An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe. 1 fig.
Hale, Charles J.
1983-01-01
An assembly for mounting a pH probe in a flowing solution, such as a sanitary sewer line, which prevents the sensitive glass portion of the probe from becoming coated with grease, oil, and other contaminants, whereby the probe gives reliable pH indication over an extended period of time. The pH probe assembly utilizes a special filter media and a timed back-rinse feature for flushing clear surface contaminants of the filter. The flushing liquid is of a known pH and is utilized to check performance of the probe.
NASA Astrophysics Data System (ADS)
Kenney, Janice P. L.; Song, Zhen; Bunker, Bruce A.; Fein, Jeremy B.
2012-06-01
In this study, we examine the initial interactions between aqueous Au(III)-hydroxide-chloride aqueous complexes and bacteria by measuring the effects of non-metabolizing cells on the speciation and distribution of Au. We conducted batch Au(III) removal experiments, measuring the kinetics and pH dependence of Au removal, and tracking valence state transformations and binding environments using XANES spectroscopy. These experiments were conducted using non-metabolizing cells of Bacillus subtilis or Pseudomonas putida suspended in a 5 ppm Au(III)-(hydroxide)-chloride starting solution of 0.1 M NaClO4 to buffer ionic strength. Both bacterial species removed greater than 85% of the Au from solution after 2 h of exposure time below approximately pH 5. Above pH 5, the extent of Au removed from solution decreased with increasing pH, with less than approximately 10% removal of Au from solution above pH 7.5. Kinetics experiments indicated that the Au removal with both bacterial species was rapid at pH 3, and slowed with increasing pH. Reversibility experiments demonstrated that (1) once the Au was removed from solution, adjusting 35 the pH alone did not remobilize the Au into solution and (2) the presence of cysteine in solution in the reversibility experiments caused Au to desorb, suggesting that the Au was not internalized within the bacterial cells. Our results suggest that Au removal occurs as a two-step pH-dependent adsorption reduction process. The speciation of the aqueous Au and the bacterial surface appears to control the rate of Au removal from solution. Under low pH conditions, the cell walls are only weakly negatively charged and aqueous Au complexes adsorb readily and rapidly. With increasing pH, the cell wall becomes more negatively charged, slowing adsorption significantly. The XANES data demonstrate that the reduction of Au(III) by bacterial exudates is slower and less extensive than the reduction observed in the bacteria-bearing systems, and we conclude that Au reduction occurs most rapidly and extensively upon interaction with cell wall functional groups.
Liu, Xianli; Wu, Feng; Deng, Nansheng
2004-01-01
Photoproduction of hydroxyl radicals (*OH) could be induced in aqueous solution with algae (Nitzschia hantzschiana, etc.) and (or not) Fe3+ under high-pressure mercury lamp with an exposure time of 4 h. *OH was determined by HPLC using benzene as a probe. The photoproduction of *OH increased with increasing algae concentration. Fe3+ could enhance the photoproduction of *OH in aqueous solution with algae. The results showed that the photoproduction of *OH in algal solution with Fe3+ was greater than that in algal solution without Fe3+. The light intensity and pH affected the photoproduction of *OH in aqueous solution with algae with/without Fe3+. The photoproduction of *OH in aqueous solution with algae and Fe3+ under 250 W was greater than that under 125 W HPML. The photoproduction of *OH in algal solution (pH ranged from 4.0 to 7.0) with (or not) Fe3+ at pH 4 was the greatest.
Control of enzymatic browning in apple slices by using ascorbic acid under different conditions.
el-Shimi, N M
1993-01-01
Control of phenol oxidase activity in apple slices by the use of ascorbic acid at different pH values, temperature and time of incubation was investigated. The enzyme was almost inactivated at 1% and 1.5% ascorbic acid. Ascorbic acid solution (1%) caused a remarkable inhibition with the increasing acidity up to pH = 1. Heating treatments for apple slices dipped in 1% ascorbic acid caused a reduction of enzymatic browning, optimum temperature for inactivation of the enzyme was between 60-70 degrees C for 15 minutes. Increasing the time of dipping apple slices in 1% ascorbic acid solutions and at different pH values reduce phenolase activity.
Slow equilibration of reversed-phase columns for the separation of ionized solutes.
Marchand, D H; Williams, L A; Dolan, J W; Snyder, L R
2003-10-10
Reversed-phase columns that have been stored in buffer-free solvents can exhibit pronounced retention-time drift when buffered, low-pH mobile phases are used with ionized solutes. Whereas non-ionized compounds exhibit constant retention times within 20 min of the beginning of mobile phase flow, the retention of ionized compounds can continue to change (by 20% or more) for several hours. If mobile phase pH is changed from low to high and back again, an even longer time may be required before the column reaches equilibration at low pH. The speed of column equilibration for ionized solutes can vary significantly among different reversed-phase columns and is not affected by flow rate.
Conformal self-assembled thin films for optical pH sensors
NASA Astrophysics Data System (ADS)
Topasna, Daniela M.; Topasna, Gregory A.; Liu, Minghanbo; Tseng, Ching-Hung
2016-04-01
Simple, reliable, lightweight, and inexpensive thin films based sensors are still in intense development and high demand in many applications such as biomedical, industrial, environmental, military, and consumer products. One important class of sensors is the optical pH sensor. In addition, conformal thin film based sensors extend the range of application for pH optical sensors. We present the results on the fabrication and characterization of optical pH sensing coatings made through ionic self-assembled technique. These thin films are based on the combination of a polyelectrolyte and water-soluble organic dye molecule Direct Yellow 4. A series of films was fabricated and characterized in order to determine the optimized parameters of the polymer and of the organic dye solutions. The optical pH responses of these films were also studied. The transparent films were immersed in solutions at various temperature and pH values. The films are stable when immersed in solutions with pH below 9.0 and temperatures below 90 °C and they maintain their performance after longer immersion times. We also demonstrate the functionality of these coatings as conformal films.
Antimicrobial Cellulose: Preparation and Application of 5-Methyl-5-Aminomethylhydantoin
2006-08-01
they release active chlorine to microbes relatively more rapidly and kill the pathogens in the shortest time. Amide N-Cl bonds being relatively more...for 5~35 min. A 1% Clorox solution was used for chlorination without pH adjustment. bCoating solution: 5 % AH in distilled water. cCoating solution...0.37% 0.75 % 0.94 % 0.80 % 0.80 % aThe cloth samples were cured at 1450C for 35 min and then chlorinated with 1% Clorox 12 without pH adjustment
Graphite Screen-Printed Electrodes Applied for the Accurate and Reagentless Sensing of pH.
Galdino, Flávia E; Smith, Jamie P; Kwamou, Sophie I; Kampouris, Dimitrios K; Iniesta, Jesus; Smith, Graham C; Bonacin, Juliano A; Banks, Craig E
2015-12-01
A reagentless pH sensor based upon disposable and economical graphite screen-printed electrodes (GSPEs) is demonstrated for the first time. The voltammetric pH sensor utilizes GSPEs which are chemically pretreated to form surface immobilized oxygenated species that, when their redox behavior is monitored, give a Nernstian response over a large pH range (1-13). An excellent experimental correlation is observed between the voltammetric potential and pH over the entire pH range of 1-13 providing a simple approach with which to monitor solution pH. Such a linear response over this dynamic pH range is not usually expected but rather deviation from linearity is encountered at alkaline pH values; absence of this has previously been attributed to a change in the pKa value of surface immobilized groups from that of solution phase species. This non-deviation, which is observed here in the case of our facile produced reagentless pH sensor and also reported in the literature for pH sensitive compounds immobilized upon carbon electrodes/surfaces, where a linear response is observed over the entire pH range, is explained alternatively for the first time. The performance of the GSPE pH sensor is also directly compared with a glass pH probe and applied to the measurement of pH in "real" unbuffered samples where an excellent correlation between the two protocols is observed validating the proposed GSPE pH sensor.
Humic Acid Isolations from Lignite by Ion Exchange Method
NASA Astrophysics Data System (ADS)
Kurniati, E.; Muljani, S.; Virgani, D. G.; Neno, B. P.
2018-01-01
The humic liquid is produced from lignite extraction using alkali solution. Conventional humic acid is obtained by acidifying a humic solution using HCl. The purpose of this research is the formation of solid humic acid from lignite by ion exchange method using cation resin. The results showed that the addition of cation resin was able to reduce the pH from 14 to pH 2 as well as the addition of acid (HCl), indicating the exchange of Na + ions with H + ions. The reduction of pH in the humic solution is influenced by the concentration of sodium ions in the humic solution, the weight of the cation resin, and the ion exchange time. The IR spectra results are in good agreement for humic acid from lignite characterization.
Chrysochoou, M; Reeves, K
2017-03-01
This study reports on the direct reduction of hexavalent chromium [Cr(VI)] by green tea polyphenols, including a green tea solution and pure epigallocatechin gallate (EGCG) solution. A linear trend was observed between the amount of reduced Cr(VI) and the amount of added polyphenols. The green tea solution showed a continued decrease in the observed stoichiometry with increasing pH, from a maximum of 1.4 mol per gallic acid equivalent (GAE) of green tea at pH 2.5, to 0.2 mol/GAE at pH 8.8. The EGCG solution exhibited different behavior, with a maximum stoichiometry of 2 at pH 7 and minimum of 1.6 at pH 4.4 and 8.9. When green tea was used to first react with Fe 3+ and form GT-nZVI, the amount of Cr(VI) reduced by a certain volume of GT-nZVI was double compared to green tea, and 6 times as high considering that GT-nZVI only contains 33 % green tea.
Biosorption characteristics of Uranium (VI) from aqueous solution by pollen pini.
Wang, Feihong; Tan, Lichao; Liu, Qi; Li, Rumin; Li, Zhanshuang; Zhang, Hongsen; Hu, Songxia; Liu, Lianhe; Wang, Jun
2015-12-01
Uranium biosorption from aqueous solutions by pollen pini (Pinus massoniana pollen) was studied in a bath system. The biosorbent was characterized by Fourier-transform infrared spectroscopy and scanning electron microscope. The influences of pH, contact time and initial uranium concentration at room temperature were investigated and the experimental curves were obtained. The pollen pini exhibited the highest uranium sorption capacity at pH 5.0 after 2 h contact. At pH 2.5 pollen pini also exhibited a good uranium loading capacity (>15%). Therefore biosorption characteristics of uranium from aqueous solution onto pollen pini were examined at pH 2.5 as well. The kinetics followed a pseudo-second-order rate equation and adsorption process was well fitted with the Freundlich isotherm at both pH. The adsorption of uranium by the biosorbent was confirmed by energy dispersive spectroscopy. The present study suggested that pollen pini could be a suitable biosorbent for biosorption uranium (VI) from aqueous solution in a fast, low cost and convenient approach. Copyright © 2015 Elsevier Ltd. All rights reserved.
Schulz, Volker; Guenther, Margarita; Gerlach, Gerald; Magda, Jules J.; Tathireddy, Prashant; Rieth, Loren; Solzbacher, Florian
2010-01-01
Environmental responsive or smart hydrogels show a volume phase transition due to changes of external stimuli such as pH or ionic strength of an ambient solution. Thus, they are able to convert reversibly chemical energy into mechanical energy and therefore they are suitable as sensitive material for integration in biochemical microsensors and MEMS devices. In this work, micro-fabricated silicon pressure sensor chips with integrated piezoresistors were used as transducers for the conversion of mechanical work into an appropriate electrical output signal due to the deflection of a thin silicon bending plate. Within this work two different sensor designs have been studied. The biocompatible poly(hydroxypropyl methacrylate-N,N-dimethylaminoethyl methacrylate-tetra-ethyleneglycol dimethacrylate) (HPMA-DMA-TEGDMA) was used as an environmental sensitive element in piezoresistive biochemical sensors. This polyelectrolytic hydrogel shows a very sharp volume phase transition at pH values below about 7.4 which is in the range of the physiological pH. The sensor's characteristic response was measured in-vitro for changes in pH of PBS buffer solution at fixed ionic strength. The experimental data was applied to the Hill equation and the sensor sensitivity as a function of pH was calculated out of it. The time-dependent sensor response was measured for small changes in pH, whereas different time constants have been observed. The same sensor principal was used for sensing of ionic strength. The time-dependent electrical sensor signal of both sensors was measured for variations in ionic strength at fixed pH value using PBS buffer solution. Both sensor types showed an asymmetric swelling behavior between the swelling and the deswelling cycle as well as different time constants, which was attributed to the different nature of mechanical hydrogel-confinement inside the sensor. PMID:21152365
Adsorption of malachite green dye from aqueous solution on the bamboo leaf ash
NASA Astrophysics Data System (ADS)
Kuntari, Priwidyanjati, Dessyntha Anggiani
2017-12-01
Bamboo leaf ash has been developed as an adsorbent material for removal malachite green from aqueous solution. Adsorption parameters have studied are contact time and initial pH. The effect of contact time and pH were examined in the batch adsorption processes. The physicochemical characters of bamboo leaf ash were investigated by using X-Ray Diffraction (XRD) and FT-IR spectroscopy. Malachite green concentration was determined by UV-Vis spectrophotometer. FT-IR spectrogram of bamboo leaf ash shows that typical fingerprint of adsorbent material with Si-O-Si or Al-O-Al group. The X-ray diffractograms of bamboo leaf ash show that adsorbent material has a highly amorphous nature. The percentage of adsorption was showed raised with increasing contact time. The optimum removal of malachite green when the initial dye concentration, initial pH, weight of adsorbent and contact time was 20 mg/L, 7, 0.25 g and 75 minutes respectively.
Adsorption of arsenic from aqueous solution using magnetic graphene oxide
NASA Astrophysics Data System (ADS)
Sherlala, A. I. A.; Raman, A. A.; Bello, M. M.
2017-06-01
A binary of graphene oxide (GO) and iron oxide (IO) was prepared and used for the removal of arsenic from aqueous solution. The synthesized compound was characterized using XRD analysis. The prepared composite was used for the adsorption of arsenic from aqueous solution. Central Composite Design was used to design the adsorption experiments and to investigate the effects of operational parameters (initial concentration of arsenic, adsorbent dosage, pH and time) on the adsorption capacity and efficiency. The adsorbent shows a high adsorption capacity for the arsenic. The adsorption efficiency ranges between 33.2 % and 99.95 %. The most significant factors affecting the adsorption capacity were found to be the initial concentration of arsenic and the adsorbent dosage. The initial pH of the solution slightly affects the adsorption capacity, with the maximum adsorption capacity occurring around pH 6 - 7. Thus, the developed adsorbent has a potential for effective removal of arsenic from aqueous solution.
The dissolution of calcite in CO2-saturated solutions at 25°C and 1 atmosphere total pressure
Plummer, Niel; Wigley, T.M.L.
1976-01-01
The dissolution of Iceland spar in CO2-saturated solutions at 25°C and 1 atm total pressure has been followed by measurement of pH as a function of time. Surface concentrations of reactant and product species have been calculated from bulk fluid data using mass transport theory and a model that accounts for homogeneous reactions in the bulk fluid. The surface concentrations are found to be close to bulk solution values. This indicates that calcite dissolution under the experimental conditions is controlled by the kinetics of surface reaction. The rate of calcite dissolution follows an empirical second order relation with respect to calcium and hydrogen ion from near the initial condition (pH 3.91) to approximately pH 5.9. Beyond pH 5.9 the rate of surface reaction is greatly reduced and higher reaction orders are observed. Calculations show that the rate of calcite dissolution in natural environments may be influenced by both transport and surface-reaction processes. In the absence of inhibition, relatively short times should be sufficient to establish equilibrium.
Strong adhesion and cohesion of chitosan in aqueous solutions
Lee, Dong Woog; Lim, Chanoong; Israelachvili, Jacob N.; Hwang, Dong Soo
2014-01-01
Chitosan, a load-bearing biomacromolecule found in the exoskeletons of crustaceans and insects, is a promising biopolymer for the replacement of synthetic plastic compounds. Here, surface interactions mediated by chitosan in aqueous solutions, including the effects of pH and contact time, were investigated using a surface forces apparatus (SFA). Chitosan films showed an adhesion to mica for all tested pH ranges (3.0–8.5), achieving a maximum value at pH 3.0 after a contact time of 1 hr (Wad ~6.4 mJ/m2). We also found weak or no cohesion between two opposing chitosan layers on mica in aqueous buffer until the critical contact time for maximum adhesion (chitosan-mica) was reached. Strong cohesion (Wco ~8.5 mJ/m2) between the films was measured with increasing contact times up to 1 hr at pH 3.0, which is equivalent to ~60% of the strongest, previously reported, mussel underwater adhesion. Such time-dependent adhesion properties are most likely related to molecular or molecular group reorientations and interdigitations. At high pH (8.5), the solubility of chitosan changes drastically, causing the chitosan-chitosan (cohesion) interaction to be repulsive at all separation distances and contact times. The strong contact time and pH-dependent chitosan-chitosan cohesion and adhesion properties provide new insight into the development of chitosan based load-bearing materials. PMID:24138057
Precipitation of CaCO3 due to the Uptake of CO2 in Aqueous Solutions - Mechanisms and Rates
NASA Astrophysics Data System (ADS)
Dietzel, M.; Purgstaller, B.; Rinder, T.; Niedermayr, A.
2012-12-01
In natural and man-made environments the exchange of CO2 between aqueous solutions and the atmosphere frequently induces precipitation of CaCO3 polymorphs. Liberation of gaseous CO2 is well known to induce carbonate formation and extensively studied. In contrast significant gaps of knowledge exist with respect to the combined CO2 uptake and CaCO3 formation, although it is known to be highly valid for many natural and man-made surroundings causing e.g. travertine and scaling in analogy to CO2 liberation. Recently CO2 uptake is also discussed for biomineralization issues and debated for CO2 sequestration by using alkaline residue materials. In the present study CO2 uptake and CaCO3 precipitation mechanisms and rates were experimentally studied by diffusion of CO2 through a polyethylene membrane from an inner to an outer solution containing carbonic acid and CaCl2 (10 mM), respectively. The pH of the outer solution was kept constant between 8.3 and 11.5 by pH stat. technique (25°C). At a critical Ion Activity Product (IAP) CaCO3 is formed in the outer solution. The NaOH titration curve and Ca2+ concentrations reflect CO2 uptake and CaCO3 precipitation rates. To discover the impact of a drift in pH due to CO2 uptake on CaCO3 precipitation hydrogeochemical modeling was applied. XRD, (micro)Raman pattern and SEM imaging reveal the formation of calcite and vaterite at pH 8.3 and 9, whereas at pH > 10 vaterite is additionally formed. However at a given pH the formation of individual CaCO3 polymorphs strongly depends on the CO2 uptake rate (adjusted by membrane thickness), which controls carbonate accumulation in the solution. At elevated pH of the outer solution the uptake rate of CO2 is significantly higher and less time for nucleation of CaCO3 is required compared to lower pH. Surprisingly at the total experimental time of ≈ 20 h the amount of precipitated CaCO3 is similar for all experiments. This can be explained by significant higher CaCO3 precipitation rates at low versus high pH if once a critical IAP is reached. If a drift in pH is permitted the internal Pco2 value can be used as a reliable proxy to evaluate whether uptake of CO2 results in an increase or decrease of IAP with a threshold value of 10-6.15 atm at 25°C (pH ≈ 11). The obtained relationships for CaCO3 formation through CO2 uptake are discussed for selected alkaline environments.
Devadhasan, Jasmine Pramila; Kim, Sanghyo
2015-02-09
CMOS sensors are becoming a powerful tool in the biological and chemical field. In this work, we introduce a new approach on quantifying various pH solutions with a CMOS image sensor. The CMOS image sensor based pH measurement produces high-accuracy analysis, making it a truly portable and user friendly system. pH indicator blended hydrogel matrix was fabricated as a thin film to the accurate color development. A distinct color change of red, green and blue (RGB) develops in the hydrogel film by applying various pH solutions (pH 1-14). The semi-quantitative pH evolution was acquired by visual read out. Further, CMOS image sensor absorbs the RGB color intensity of the film and hue value converted into digital numbers with the aid of an analog-to-digital converter (ADC) to determine the pH ranges of solutions. Chromaticity diagram and Euclidean distance represent the RGB color space and differentiation of pH ranges, respectively. This technique is applicable to sense the various toxic chemicals and chemical vapors by situ sensing. Ultimately, the entire approach can be integrated into smartphone and operable with the user friendly manner. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yu, Li; Shao, Mingyu; Bao, Zhenmin; Hu, Jingjie; Zhang, Zhifeng
2011-06-01
Sperm of sea cucumber Apostichopus japonicus (Selenka) were quiescent in electrolyte NaCl solution and artificial seawater (ASW) and nonelectrolyte glucose and mannitol solutions when the osmolality was less than 200 mOsm kg-1. The sperm started to be motile as a result of increased osmolality, indicating an osmolality-dependent initiation of sperm motility in sea cucumber. After a brief incubation in hypotonic NaCl and glucose solutions with osmolalities of 200 and 400 mOsm kg-1, sperm lost partial motile ability. Sperm became immobilized when pH was 6.0 in NaCl, glucose and mannitol solutions, suggesting that an H+ release is involved in sperm activation. The decreased pH had no effect on the percentage of motile sperm in ASW, whereas it delayed the time period to reach the maximum motility (motilitymax). Extracellular Ca2+ in electrolyte solutions was not essential for motility stimulation but shortened the time of reaching motilitymax. When Ca2+ was mixed in nonelectrolyte solutions the sperm motility was completely suppressed. The K+ channel blocker, quinine, suppressed the sperm motility in electrolyte solution, showing a possible involvement of K+ transport in the process. High K+ concentration did not affect the sperm motility in NaCl solution, but decreased it in ASW and almost entirely suppressed it in nonelectrolyte solutions. The different effects of pH and K+ in ASW and NaCl solution indicate that external ions may also regulate sperm motility.
Dias, A G; Gibson, I R; Santos, J D; Lopes, M A
2007-03-01
The aim of this work was to evaluate the in vitro degradation behaviour of a 45CaO-37P(2)O(5)-5MgO-13TiO(2) (mol.%) glass ceramic, under two different simulated physiological conditions: normal physiological pH 7.4, and pH 3.0, which was designed to simulate the acidic conditions produced by osteoclast cells. The in vitro testing was carried out at 37 degrees C for up to 42 days for the pH 7.4 solution and for up to 1 day for the pH 3.0 solution. The incorporation of TiO(2) into the glass structure leads to the precipitation of specific crystalline phases in the glass matrix, namely alpha- and beta-Ca(2)P(2)O(7), TiP(2)O(7) and CaTi(4)(PO(4))(6). The degradation testing at pH 3.0 showed a higher weight loss compared with degradation testing at pH 7.4; the weight loss under the acidic condition after 1 day (24 h) was about 10 times higher than the weight loss after 42 days of immersion at pH 7.4. The ionic release profile of Ca(2+), PO(4)(3-), Mg(2+) and Ti(4+) showed a continuous increase in concentration over all immersion times for both testing solutions. After 1 day of immersion at pH 3.0, the concentration levels of Mg(2+), Ca(2+), PO(4)(3-) were about six times higher than the levels achieved after 42 days of immersion at pH 7.4. The glass ceramic showed similar degradation to hydroxyapatite, and therefore has potential to be used in certain clinical applications where relatively slow resorption of the implant and replacement by bone is required, e.g. cranioplasty.
Time course of pH change in plant epidermis using microscopic pH imaging system
NASA Astrophysics Data System (ADS)
Dan, Risako; Shimizu, Megumi; Kazama, Haruko; Sakaue, Hirotaka
2010-11-01
We established a microscopic pH imaging system to track the time course of pH change in plant epidermis in vivo. In the previous research, we have found out that anthocyanin containing cells have higher pH. However, it was not clear whether the anthocyanin increased the pH or anthocyanin was synthesized result from the higher pH. Therefore, we further investigated the relationship between anthocyanin and pH change. To track the time course of pH change in plant epidermis, we established a system using luminescent imaging technique. We used HPTS (8-Hydroxypyrene-1,3,6-Trisulfonate) as pH indicator and applied excitation ratio imaging method. Luminescent image was converted to a pH distribution by obtained in vitro calibration using known pH solution. Cellular level observation was enabled by merging microscopic color picture of the same region to the pH change image. The established system was applied to epidermal cells of red-tip leaf lettuce, Lactuca Sativa L. and the time course was tracked in the growth process. We would discuss about the relationship between anthocyanin and pH change in plant epidermis.
Removal of phosphate from aqueous solutions and sewage using natural and surface modified coir pith.
Krishnan, K Anoop; Haridas, Ajit
2008-04-01
Iron impregnated coir pith (CP-Fe-I) can be effectively used for the removal of phosphate from aqueous streams and sewage. Iron impregnation on natural coir pith was carried out by drop by drop addition method. The effect of various factors such as pH, initial concentration of phosphate, contact time and adsorbent dose on phosphate adsorption was studied by batch technique. The pH at 3.0 favored the maximum adsorption of phosphate from aqueous solutions. The effect of pH on phosphate adsorption was explained by pH(zpc), phosphate speciation in solution and affinity of anions towards the adsorbent sites. A comparative study of the adsorption of phosphate using CP-Fe-I and CP (coir pith) was made and results show that the former one is five to six times more effective than the latter. Kinetic studies revealed that the adsorption process followed a pseudo-second order kinetic model. Adsorption followed Langmuir isotherm model. Column studies were conducted to examine the utility of the investigated adsorbent for the removal of phosphate from continuously flowing aqueous solutions.
Synthesis and Characterization of Allophane-Like as Chromium (Cr) Ion Adsorbent
NASA Astrophysics Data System (ADS)
Pranoto; Purnawan, C.; Husnina, A. N.
2018-03-01
The synthesis and characterization of allophane-like as chrom (Cr) ion adsorbent has been studied. The objectives of this study is to determine the characteristics of allophane-like and determine ratio of Al/Si, chromium solution pH, and contact time to get the best decreasing metal ion chrom (Cr) adsorption condition. The study was conducted with the ratio of Al/Si ratios 0.5; 0.75; 1.0; 1.25 and 1.5 from Tetraetyl Orthosilicate (TEOS) solution and Aluminium Nitrate Nonahydrate [Al(NO3)3.9H2O] in pH 3-4. The result of synthetic was characterized on functional groups and cristallinity. Experiment of adsorption ability using variation of Cr solution pH 3-7, contact time 30, 60, 90 and 120 minutes with batch method. The results by FTIR shows that functional groups-OH, the asymmetry groups O-Si-O or O-Al-O, relatively weak absorption which stronger then the presence of OH and bending vibration Si-O or Al-O on allophane-like. The best conditions of chromium metal adsorption with adsorbent allophane-like was obtained at pH 5, contact time 90 minutes, and the ratio Al/Si 1.5. Types of adsorption in this study follows Freundlich and Langmuir isotherm.
Xu, Fuyuan; Deng, Shubo; Xu, Jie; Zhang, Wang; Wu, Min; Wang, Bin; Huang, Jun; Yu, Gang
2012-04-17
A novel Ni-Fe bimetal with high dechlorination activity for 4-chlorophenol (4-CP) was prepared by ball milling (BM) in this study. Increasing Ni content and milling time greatly enhanced the dechlorination activity, which was mainly attributed to the homogeneous distribution of Ni nanoparticles (50-100 nm) in bulk Fe visualized by scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) with image mapping. In comparison with the Ni-Fe bimetal prepared by a chemical solution deposition (CSD) process, the ball milled Ni-Fe bimetal possessed high dechlorination activity and stability before being used up. Dechlorination kinetics indicated that the dechlorination rates of 4-CP increased with increasing Ni-Fe dose but decreased with increasing solution pH. Solution pH had a significant effect on the dechlorination of 4-CP and the passivation of the Ni-Fe bimetal. The enhanced pH during the dechlorination process significantly accelerated the formation of passivating film on the bimetallic surface. The Ni-Fe bimetal at the dose of 60 g/L was reused 10 times without losing dechlorination activity for 4-CP at initial pH less than 6.0, but the gradual passivation was observed at initial pH above 7.0.
Luo, Y M; Yan, W D; Christie, P
2001-01-01
A pot experiment was conducted to study soil solution dynamics of Cu and Zn in a Cu/Zn-polluted soil as influenced by gamma-irradiation and Cu-Zn interaction. A slightly acid sandy loam was amended with Cu and Zn (as nitrates) either singly or in combination (100 mg Cu and 150 mg Zn kg(-1) soil) and was then gamma-irradiated (10 kGy). Unamended and unirradiated controls were included, and spring barley (Hordeum vulgare L. cv. Forrester) was grown for 50 days. Soil solution samples obtained using soil moisture samplers immediately before transplantation and every ten days thereafter were used directly for determination of Cu, Zn, pH and absorbance at 360 nm (A360). Cu and Zn concentrations in the solution of metal-polluted soil changed with time and were affected by gamma-irradiation and metal interaction. gamma-Irradiation raised soil solution Cu substantially but generally decreased soil solution Zn. These trends were consistent with increased dissolved organic matter (A360) and solution pH after gamma-irradiation. Combined addition of Cu and Zn usually gave higher soil solution concentrations of Cu or Zn compared with single addition of Cu or Zn in gamma-irradiated and non-irradiated soils, indicating an interaction between Cu and Zn. Cu would have been organically complexed and consequently maintained a relatively high concentration in the soil solution under higher pH conditions. Zn tends to occur mainly as free ion forms in the soil solution and is therefore sensitive to changes in pH. The extent to which gamma-irradiation and metal interaction affected solubility and bioavailability of Cu and Zn was a function of time during plant growth. Studies on soil solution metal dynamics provide very useful information for understanding metal mobility and bioavailability.
Rajasekharan, Sivaprakash; Vercruysse, Chris; Martens, Luc; Verbeeck, Ronald
2018-01-13
Tricalcium silicate cements (TSC) are used in dental traumatology and endodontics for their bioactivity which is mostly attributed to formation of calcium hydroxide during TSC hydration and its subsequent release of calcium and hydroxide ions. The aim of this study was to determine the effect of volume (Vol), exposed surface area (ESA) and pH of surrounding medium on calcium ion release. Three commercially available hydraulic alkaline dental cements were mixed and condensed into cylindrical tubes of varying length and diameter ( n = 6/group). For the effect of ESA and Vol, tubes were immersed in 10 mL of deionized water. To analyze the effect of environmental pH, the tubes were randomly immersed in 10 mL of buffer solutions with varying pH (10.4, 7.4 or 4.4). The solutions were collected and renewed at various time intervals. pH and/or calcium ion release was measured using a pH glass electrode and atomic absorption spectrophotometer respectively. The change of pH, short-term calcium ion release and rate at which calcium ion release reaches maximum were dependent on ESA ( p < 0.05) while maximum calcium ion release was dependent on Vol of TSC ( p < 0.05). Maximum calcium ion release was significantly higher in acidic solution followed by neutral and alkaline solution ( p < 0.05).
Rajasekharan, Sivaprakash; Vercruysse, Chris; Martens, Luc; Verbeeck, Ronald
2018-01-01
Tricalcium silicate cements (TSC) are used in dental traumatology and endodontics for their bioactivity which is mostly attributed to formation of calcium hydroxide during TSC hydration and its subsequent release of calcium and hydroxide ions. The aim of this study was to determine the effect of volume (Vol), exposed surface area (ESA) and pH of surrounding medium on calcium ion release. Three commercially available hydraulic alkaline dental cements were mixed and condensed into cylindrical tubes of varying length and diameter (n = 6/group). For the effect of ESA and Vol, tubes were immersed in 10 mL of deionized water. To analyze the effect of environmental pH, the tubes were randomly immersed in 10 mL of buffer solutions with varying pH (10.4, 7.4 or 4.4). The solutions were collected and renewed at various time intervals. pH and/or calcium ion release was measured using a pH glass electrode and atomic absorption spectrophotometer respectively. The change of pH, short-term calcium ion release and rate at which calcium ion release reaches maximum were dependent on ESA (p < 0.05) while maximum calcium ion release was dependent on Vol of TSC (p < 0.05). Maximum calcium ion release was significantly higher in acidic solution followed by neutral and alkaline solution (p < 0.05). PMID:29342837
Narang, Ajit S; Badawy, Sherif; Ye, Qingmei; Patel, Dhaval; Vincent, Maria; Raghavan, Krishnaswamy; Huang, Yande; Yamniuk, Aaron; Vig, Balvinder; Crison, John; Derbin, George; Xu, Yan; Ramirez, Antonio; Galella, Michael; Rinaldi, Frank A
2015-08-01
Precipitation of weakly basic drugs in intestinal fluids can affect oral drug absorption. In this study, the implications of self-association of brivanib alaninate in acidic aqueous solution, leading to supersaturation at basic pH condition, on its solubility and oral absorption were investigated. Self-association of brivanib alaninate was investigated by proton NMR spectroscopy, surface tension measurement, dynamic light scattering, isothermal titration calorimetry, and molecular modeling. Drug solubility was determined in various pH media, and its tendency to supersaturate upon pH shift was investigated in buffered and biorelevant aqueous solutions. Pharmacokinetic modeling of human oral drug absorption was utilized for parameter sensitivity analyses of input variables. Brivanib alaninate exhibited continuous, and pH- and concentration-dependent self-association. This phenomenon resulted in positive deviation of drug solubility at acidic pH and the formation of a stable supersaturated drug solution in pH-shift assays. Consistent with the supersaturation phenomenon observed in vitro, oral absorption simulations necessitated invoking long precipitation time in the intestine to successfully predict in vivo data. Self-association of a weakly basic drug in acidic aqueous solution can increase its oral absorption by supersaturation and precipitation resistance at the intestinal pH. This consideration is important to the selection of parameters for oral absorption simulation.
di Nunzio, Maria Rosaria; Douhal, Yasmin; Organero, Juan Angel; Douhal, Abderrazzak
2018-05-23
This work reports on photophysical studies of the irinotecan (IRT) anti-cancer drug in water solutions of different acidities (pH = 1.11-9.46). We found that IRT co-exists as mono-cationic (C1), di-cationic (C2), or neutral (N) forms. The population of each prototropic species depends on the pH of the solution. At pH = 1.11-3.01, the C1 and C2 structures are stabilized. At pH = 7.00, the most populated species is C1, while at pH values larger than 9.46 the N form is the most stable species. In the 1.11-2.61 pH range, the C1* emission is efficiently quenched by protons to give rise to the emission from C2*. The dynamic quenching constant, KD, is ∼32 M-1. While the diffusion governs the rate of excited-state proton-transfer (ESPT) under these conditions, the reaction rate increases with the proton concentration. A two-step diffusive Debye-Smoluchowski model was applied at pH = 1.11-2.61 to describe the protonation of C1*. The ESPT time constants derived for C1* are 382 and 1720 ps at pH = 1.11 and 1.95, respectively. We found that one proton species is involved in the protonation of C1* to give C2*, in the analyzed acidic pH range. Under alkaline conditions (pH = 9.46), the N form is the most stable structure of IRT. These results indicate the influence of the pH of the medium on the structural and dynamical properties of IRT in water solution. They may help to provide a better understanding on the relationship between the structure and biological activity of IRT.
Casella, Amanda J; Ahlers, Laura R H; Campbell, Emily L; Levitskaia, Tatiana G; Peterson, James M; Smith, Frances N; Bryan, Samuel A
2015-05-19
In nuclear fuel reprocessing, separating trivalent minor actinides and lanthanide fission products is extremely challenging and often necessitates tight pH control in TALSPEAK (Trivalent Actinide-Lanthanide Separation by Phosphorus reagent Extraction from Aqueous Komplexes) separations. In TALSPEAK and similar advanced processes, aqueous pH is one of the most important factors governing the partitioning of lanthanides and actinides between an aqueous phase containing a polyaminopolycarboxylate complexing agent and a weak carboxylic acid buffer and an organic phase containing an acidic organophosphorus extractant. Real-time pH monitoring would significantly increase confidence in the separation performance. Our research is focused on developing a general method for online determination of the pH of aqueous solutions through chemometric analysis of Raman spectra. Spectroscopic process-monitoring capabilities, incorporated in a counter-current centrifugal contactor bank, provide a pathway for online, real-time measurement of solution pH. The spectroscopic techniques are process-friendly and can be easily configured for online applications, whereas classic potentiometric pH measurements require frequent calibration/maintenance and have poor long-term stability in aggressive chemical and radiation environments. Raman spectroscopy discriminates between the protonated and deprotonated forms of the carboxylic acid buffer, and the chemometric processing of the Raman spectral data with PLS (partial least-squares) regression provides a means to quantify their respective abundances and therefore determine the solution pH. Interpretive quantitative models have been developed and validated under a range of chemical composition and pH conditions using a lactic acid/lactate buffer system. The developed model was applied to new spectra obtained from online spectral measurements during a solvent extraction experiment using a counter-current centrifugal contactor bank. The model predicted the pH of this validation data set within 11% for pH > 2, thus demonstrating that this technique could provide the capability of monitoring pH online in applications such as nuclear fuel reprocessing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 150.25 pH (1) (1) 1 Within the range of 7.0 to 10.0 at all times. Subpart C Solution Heat Treatment... wastewater in which case the pH shall be within the range of 6.0 to 10.0 at all times. Subpart C Press Heat...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 150.25 pH (1) (1) 1 Within the range of 7.0 to 10.0 at all times. Subpart C Solution Heat Treatment... wastewater in which case the pH shall be within the range of 6.0 to 10.0 at all times. Subpart C Press Heat...
Costa, Solange Alves da Silva; Paula, Olívia Ferreira Pereira de; Silva, Célia Regina Gonçalves E; Leão, Mariella Vieira Pereira; Santos, Silvana Soléo Ferreira dos
2015-01-01
The instruments and materials used in health establishments are frequently exposed to microorganism contamination, and chemical products are used before sterilization to reduce occupational infection. We evaluated the antimicrobial effectiveness, physical stability, and corrosiveness of two commercial formulations of peracetic acid on experimentally contaminated specimens. Stainless steel specimens were contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, blood, and saliva and then immersed in a ready peracetic acid solution: 2% Sekusept Aktiv (SA) or 0.25% Proxitane Alpha (PA), for different times. Then, washes of these instruments were plated in culture medium and colony-forming units counted. This procedure was repeated six times per day over 24 non-consecutive days. The corrosion capacity was assessed with the mass loss test, and the concentration of peracetic acid and pH of the solutions were measured with indicator tapes. Both SA and PA significantly eliminated microorganisms; however, the SA solution was stable for only 4 days, whereas PA remained stable throughout the experiment. The concentration of peracetic acid in the SA solutions decreased over time until the chemical was undetectable, although the pH remained at 5. The PA solution had a concentration of 500-400 mg/L and a pH of 2-3. Neither formulation induced corrosion and both reduced the number of microorganisms (p = 0.0001). However, the differences observed in the performance of each product highlight the necessity of establishing a protocol for optimizing the use of each one.
Removal of six pesticide residues in cowpea with alkaline electrolysed water.
Han, Yongtao; Song, Le; An, Quanshun; Pan, Canping
2017-06-01
Reduction of six pesticide residues (isoprocarb, chlorpyrifos, bifenthrin, beta-cypermethrin, difenoconazole and azoxystrobin) in cowpea by alkaline electrolysed water (AlEW) solutions with different pH was investigated. The commonly used washing treatments in household processing were used for comparison. The residue magnitudes were determined by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). Results showed that the removal effect of AlEW solution on the six pesticides was superior to tap water, 5% sodium chloride, 5% sodium carbonate and 5% acetic acid solution. AlEW with pH 12.2 had more potential to eliminate the six pesticides in cowpeas. Moreover, the reduction of pesticide residues gradually increased with the increase of washing time. This study demonstrated that AlEW solution with pH of 12.2 could be used to reduce pesticide residues on fresh cowpea samples. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Stability of urea in solution and pharmaceutical preparations.
Panyachariwat, Nattakan; Steckel, Hartwig
2014-01-01
The stability of urea in solution and pharmaceutical preparations was analyzed as a function of temperature (25°-60°C), pH (3.11-9.67), and initial urea concentration (2.5%-20%). This study was undertaken to (i) obtain more extensive, quantitative information relative to the degradation of urea in both aqueous and non-aqueous solutions and in pharmaceutical preparations, and (ii) test the effects of initial urea concentration, pH, buffer, and temperature values on urea degradation. The stability analysis shows that urea is more stable at the pH range of 4-8 and the stability of urea decreases by increase in temperature for all pH values. Within the experimental range of temperature and initial urea concentration values, the lowest urea degradation was found with lactate buffer pH 6.0. The urea decomposition rate in solution and pharmaceutical preparations shows the dependence of the initial urea concentrations. At higher initial urea concentrations, the rate of degradation is a decreasing function with time. This suggests that the reverse reaction is a factor in the degradation of concentrated urea solution. For non-aqueous solvents, isopropanol showed the best effort in retarding the decomposition of urea. Since the losses in urea is directly influenced by its stability at a given temperature and pH, the stability analysis of urea by the proposed model can be used to prevent the loss and optimize the operating condition for urea-containing pharmaceutical preparations.
Aqueous photolysis of niclosamide
Graebing, P.W.; Chib, J.S.; Hubert, T.D.; Gingerich, W.H.
2004-01-01
The photodegradation of [14C]niclosamide was studied in sterile, pH 5, 7, and 9 buffered aqueous solutions under artificial sunlight at 25.0 A? 1.0 A?C. Photolysis in pH 5 buffer is 4.3 times faster than in pH 9 buffer and 1.5 times faster than in pH 7 buffer. In the dark controls, niclosamide degraded only in the pH 5 buffer. After 360 h of continuous irradiation in pH 9 buffer, the chromatographic pattern of the degradates was the same regardless of which ring contained the radiolabel. An HPLC method was developed that confirmed these degradates to be carbon dioxide and two- and four-carbon aliphatic acids formed by cleavage of both aromatic rings. Carbon dioxide was the major degradate, comprising 40% of the initial radioactivity in the 360 h samples from both labels. The other degradates formed were oxalic acid, maleic acid, glyoxylic acid, and glyoxal. In addition, in the chloronitroaniline-labeled irradiated test solution, 2-chloro-4-nitroaniline was observed and identified after 48 h of irradiation but was not detected thereafter. No other aromatic compounds were isolated or observed in either labeled test system.
Stress corrosion study of PH13-8Mo stainless steel using the Slow Strain Rate Technique
NASA Technical Reports Server (NTRS)
Torres, Pablo D.
1989-01-01
The need for a fast and reliable method to study stress corrosion in metals has caused increased interest in the Slow Strain Rate Technique (SSRT) during the last few decades. PH13-8MoH950 and H1000 round tensile specimens were studied by this method. Percent reduction-in-area, time-to-failure, elongation at fracture, and fracture energy were used to express the loss in ductility, which has been used to indicate susceptibility to stress corrosion cracking (SCC). Results from a 3.5 percent salt solution (corrosive medium) were compared to those in air (inert medium). A tendency to early failure was found when testing in the vicinity of 1.0 x 10(-6) mm/mm/sec in the 3.5 percent salt solution. PH13-8Mo H1000 was found to be less likely to suffer SCC than PH13-8Mo H950. This program showed that the SSRT is promising for the SCC characterization of metals and results can be obtained in much shorter times (18 hr for PH steels) than those required using conventional techniques.
"Biocompatible" Neutral pH Low-GDP Peritoneal Dialysis Solutions: Much Ado About Nothing?
Misra, Paraish S; Nessim, Sharon J; Perl, Jeffrey
2017-03-01
Adverse outcomes in peritoneal dialysis (PD), including PD related infections, the loss of residual kidney function (RKF), and longitudinal, deleterious changes in peritoneal membrane function continue to limit the long-term success of PD therapy. The observation that these deleterious changes occur upon exposure to conventional glucose-based PD solutions fuels the search for a more biocompatible PD solution. The development of a novel PD solution with a neutral pH, and lower in glucose degradation products (GDPs) compared to its conventional predecessors has been labeled a "biocompatible" solution. While considerable evidence in support of these novel solutions' biocompatibility has emerged from cell culture and animal studies, the clinical benefits as compared to conventional PD solutions are less clear. Neutral pH low GDP (NpHLGDP) PD solutions appear to be effective in reducing infusion pain, but their effects on other clinical endpoints including peritoneal membrane function, preservation of RKF, PD-related infections, and technique and patient survival are less clear. The literature is limited by studies characterized by relatively few patients, short follow-up time, heterogeneity with regards to the novel PD solution type under study, and the different patient populations under study. Nonetheless, the search for a more biocompatible PD solution continues with emerging data on promising non glucose-based solutions. © 2017 Wiley Periodicals, Inc.
Liu, Cheng-Chung; Chen, Guan-Bu
2013-01-15
Soil washing using an acid solution is a common practice for removing heavy metals from contaminated soil in Taiwan. However, serious loss of nutrients from soil is a major drawback of the washing. Distillery sludge can be used to prepare a dissolved organic matter (DOM) solution by extracting its organic constituents with alkaline solutions. This study employed DOM solutions to remediate Cd-contaminated soil (with concentrations up to 21.5 mg kg(-1)) and determine the factors affecting removal of Cd, such as pH, initial concentration of DOM solution, temperature, and washing frequency. When washing with pH 3.0 and 1250 mg L(-1) DOM solution, about 80% and 81% of Cd were removed from the topsoil at 27 °C and subsoil at 40 °C, respectively. To summarize the changes in fertility during DOM washing with various pH solutions: the increase in organic matter content ranged from 7.7% to 23.7%; cation exchange capacity (CEC) ranged from 4.6% to 13.9%; available ammonium (NNH(4)) content ranged from 39.4% to 2175%; and available phosphorus content ranged from 34.5% to 182%. Exchangeable K, Ca, and Mg remained in the topsoil after DOM washing, with concentrations of 1.1, 2.4, and 1.5 times higher than those treated with HCl solution at the same pH, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
Diffusion of water-soluble sorptive drugs in HEMA/MAA hydrogels.
Liu, D E; Dursch, T J; Taylor, N O; Chan, S Y; Bregante, D T; Radke, C J
2016-10-10
We measure and, for the first time, theoretically predict four prototypical aqueous-drug diffusion coefficients in five soft-contact-lens material hydrogels where solute-specific adsorption is pronounced. Two-photon fluorescence confocal microscopy and UV/Vis-absorption spectrophotometry assess transient solute concentration profiles and concentration histories, respectively. Diffusion coefficients are obtained for acetazolamide, riboflavin, sodium fluorescein, and theophylline in 2-hydroxyethyl methacrylate/methacrylic acid (HEMA/MAA) copolymer hydrogels as functions of composition, equilibrium water content (30-90%), and aqueous pH (2 and 7.4). At pH2, MAA chains are nonionic, whereas at pH7.4, MAA chains are anionic (pKa≈5.2). All studied prototypical drugs specifically interact with HEMA and nonionic MAA (at pH2) moieties. Conversely, none of the prototypical drugs adsorb specifically to anionic MAA (at pH7.4) chains. As expected, diffusivities of adsorbing solutes are significantly diminished by specific interactions with hydrogel strands. Despite similar solute size, relative diffusion coefficients in the hydrogels span several orders of magnitude because of varying degrees of solute interactions with hydrogel-polymer chains. To provide a theoretical framework for the new diffusion data, we apply an effective-medium model extended for solute-specific interactions with hydrogel copolymer strands. Sorptive-diffusion kinetics is successfully described by local equilibrium and Henry's law. All necessary parameters are determined independently. Predicted diffusivities are in good agreement with experiment. Copyright © 2016 Elsevier B.V. All rights reserved.
Electrochemical Induced Calcium Phosphate Precipitation: Importance of Local pH
2017-01-01
Phosphorus (P) is an essential nutrient for living organisms and cannot be replaced or substituted. In this paper, we present a simple yet efficient membrane free electrochemical system for P removal and recovery as calcium phosphate (CaP). This method relies on in situ formation of hydroxide ions by electro mediated water reduction at a titanium cathode surface. The in situ raised pH at the cathode provides a local environment where CaP will become highly supersaturated. Therefore, homogeneous and heterogeneous nucleation of CaP occurs near and at the cathode surface. Because of the local high pH, the P removal behavior is not sensitive to bulk solution pH and therefore, efficient P removal was observed in three studied bulk solutions with pH of 4.0 (56.1%), 8.2 (57.4%), and 10.0 (48.4%) after 24 h of reaction time. While P removal efficiencies are not generally affected by bulk solution pH, the chemical-physical properties of CaP solids collected on the cathode are still related to bulk solution pH, as confirmed by structure characterizations. High initial solution pH promotes the formation of more crystalline products with relatively high Ca/P molar ratio. The Ca/P molar ratio increases from 1.30 (pH 4.0) to 1.38 (pH 8.2) and further increases to 1.55 (pH 10.0). The formation of CaP precipitates was a typical crystallization process, with an amorphous phase formed at the initial stage which then transforms to the most stable crystal phase, hydroxyapatite, which is inferred from the increased Ca/P molar ratio from 1.38 (day 1) to the theoretical 1.76 (day 11) and by the formation of needle-like crystals. Finally, we demonstrated the efficiency of this system for real wastewater. This, together with the fact that the electrochemical method can work at low bulk pH, without dosing chemicals and a need for a separation process, highlights the potential application of the electrochemical method for P removal and recovery. PMID:28872838
Inorganic Carbon Source for Photosynthesis in the Seagrass Thalassia hemprichii (Ehrenb.) Aschers.
Abel, K M
1984-11-01
Photosynthetic carbon uptake of the tropical seagrass Thalassia hemprichii (Ehrenb.) Aschers was studied by several methods. Photosynthesis in buffered seawater in media in the range of pH 6 to pH 9 showed an exponentially increasing rate with decreasing pH, thus indicating that free CO(2) was a photosynthetic substrate. However, these experiments were unable to determine whether photosynthesis at alkaline pH also contained some component due to HCO(3) (-) uptake. This aspect was further investigated by studying photosynthetic rates in a number of media of varying pH (7.8-8.61) and total inorganic carbon (0.75-13.17 millimolar). In these media, photosynthetic rate was correlated with free CO(2) concentration and was independent of the HCO(3) (-) concentration in the medium. Short time-course experiments were conducted during equilibration of free CO(2) and HCO(3) (-) after injection of (14)C labeled solution at acid or alkaline pH. High initial photosynthetic rates were observed when acidic solutions (largely free CO(2)) were used but not with alkaline solutions. The concentration of free CO(2) was found to be a limiting factor for photosynthesis in this plant.
Arsenic removal from acidic solutions with biogenic ferric precipitates.
Ahoranta, Sarita H; Kokko, Marika E; Papirio, Stefano; Özkaya, Bestamin; Puhakka, Jaakko A
2016-04-05
Treatment of acidic solution containing 5g/L of Fe(II) and 10mg/L of As(III) was studied in a system consisting of a biological fluidized-bed reactor (FBR) for iron oxidation, and a gravity settler for iron precipitation and separation of the ferric precipitates. At pH 3.0 and FBR retention time of 5.7h, 96-98% of the added Fe(II) precipitated (99.1% of which was jarosite). The highest iron oxidation and precipitation rates were 1070 and 28mg/L/h, respectively, and were achieved at pH 3.0. Subsequently, the effect of pH on arsenic removal through sorption and/or co-precipitation was examined by gradually decreasing solution pH from 3.0 to 1.6 (feed pH). At pH 3.0, 2.4 and 1.6, the highest arsenic removal efficiencies obtained were 99.5%, 80.1% and 7.1%, respectively. As the system had ferric precipitates in excess, decreased arsenic removal was likely due to reduced co-precipitation at pH<2.4. As(III) was partially oxidized to As(V) in the system. In shake flask experiments, As(V) sorbed onto jarosite better than As(III). Moreover, the sorption capacity of biogenic jarosite was significantly higher than that of synthetic jarosite. The developed bioprocess simultaneously and efficiently removes iron and arsenic from acidic solutions, indicating potential for mining wastewater treatment. Copyright © 2015 Elsevier B.V. All rights reserved.
Evolution of Spatial pH Distribution in Aqueous Solution induced by Atmospheric Pressure Plasma
NASA Astrophysics Data System (ADS)
Takahashi, Shigenori; Mano, Kakeru; Hayashi, Yui; Takada, Noriharu; Kanda, Hideki; Goto, Motonobu
2016-09-01
Discharge plasma at gas-liquid interface produces some active species, and then they affect chemical reactions in aqueous solution, where pH of aqueous solution is changed due to redox species. The pH change of aqueous solution is an important factor for chemical reactions. However, spatial pH distribution in a reactor during the discharge has not been clarified yet. Thus, this work focused on spatial pH distribution of aqueous solution when pulsed discharge plasma was generated from a copper electrode in gas phase to aqueous solution in a reactor. Experiments were conducted using positive unipolar pulsed power. The unipolar pulsed voltage at +8.0 kV was applied to the copper electrode and the bottom of the reactor was grounded. The size of the reactor was 80 mm wide, 10 mm deep, and 40 mm high. The electrode was set at distance of 2 mm from the solution surface. Anthocyanins were contained in the aqueous solution as a pH indicator. The change pH solution spread horizontally, and low pH region of 10 mm in depth was formed. After discharge for 10 minutes, the low pH region was diffused toward the bottom of the reactor. After discharge for 60 minutes, the pH of the whole solution decreased.
Zhou, Zhenming; Liu, Qidi; Li, Shuwen; Li, Fei; Zou, Jing; Liao, Xiaobin; Yuan, Baoling; Sun, Wenjie
2018-04-26
This study focused on characterizing the correlation between the dephosphorization process of calcined water treatment plant sludge (C-WTPS) and the solution initial pH in batch experiments. The specific aim was to illustrate the effect of different initial pH on the adsorption and desorption of phosphorous in C-WTPS. In addition, the effects of solution initial pH on the release of ammonia nitrogen and total organic carbon (TOC) from C-WTPS and the change of pH after adsorption were also investigated. The results demonstrated that the initial pH significantly influenced the adsorption of phosphorus on C-WTPS. When initial pH was increased from 3 to 10, the phosphorous absorption capacity reduced by 76.5%. Especially, when the initial pH reached to 11, the phosphorus adsorption capacity became a negative value, indicating that C-WTPS released phosphorus into the solution. The addition of C-WTPS to the solution had little impact on the initial pH of the solution. The absorbed phosphorous on C-WTPS was relatively stable in the pH range of 3 to 10. Nevertheless, when the solution pH was higher than 11, it can be easily released into the solution. Furthermore, by comparison with WTPS, C-WTPS released less ammonia nitrogen and TOC into the solution and adsorbed more phosphorus from the solution in the experimental pH range. Therefore, C-WTPS is more suitable to serve as a cost-effective sorbent for phosphorus removal.
Chiang, Po-Neng; Tong, Ou-Yang; Chiou, Chyow-San; Lin, Yu-An; Wang, Ming-Kuang; Liu, Cheng-Chung
2016-01-15
A liquid fertilizer obtained through food-waste composting can be used for the preparation of a dissolved organic carbon (DOC) solution. In this study, we used the DOC solutions for the remediation of a Zn-contaminated soil (with Zn concentrations up to 992 and 757 mg kg(-1) in topsoil and subsoil, respectively). We then determined the factors that affect Zn removal, such as pH, initial concentration of DOC solution, and washing frequency. Measurements using a Fourier Transform infrared spectrometer (FT-IR) revealed that carboxyl and amide were the major functional groups in the DOC solution obtained from the liquid fertilizer. Two soil washes using 1,500 mg L(-1) DOC solution with a of pH 2.0 at 25°C removed about 43% and 21% of the initial Zn from the topsoil and subsoil, respectively. Following this treatment, the pH of the soil declined from 5.4 to 4.1; organic matter content slightly increased from 6.2 to 6.5%; available ammonium (NH4(+)-N) content increased to 2.4 times the original level; and in the topsoil, the available phosphorus content and the exchangeable potassium content increased by 1.65 and 2.53 times their initial levels, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.
Corrosion inhibition by inorganic cationic inhibitors on the high strength alumunium alloy, 2024-T3
NASA Astrophysics Data System (ADS)
Chilukuri, Anusha
The toxicity and carcinogenic nature of chromates has led to the investigation of environmentally friendly compounds that offer good corrosion resistance to AA 2024-T3. Among the candidate inhibitors are rare earth metal cationic (REM) and zinc compounds, which have received much of attention over the past two decades. A comparative study on the corrosion inhibition caused by rare earth metal cations, Ce3+, Pr3+, La3+ and Zn2+ cations on the alloy was done. Cathodic polarization showed that these inhibitor ions suppress the oxygen reduction reaction (ORR) to varying extents with Zn2+ providing the best inhibition. Pr3+ exhibited windows of concentration (100-300 ppm) in which the corrosion rate is minimum; similar to the Ce3+ cation. Scanning Electron Microscopy (SEM) studies showed that the mechanism of inhibition of the Pr3+ ion is also similar to that of the Ce3+ ion. Potentiodynamic polarization experiments after 30 min immersion time showed greatest suppression of oxygen reduction reaction in neutral chloride solutions (pH 7), which reached a maximum at a Zn2+ ion concentration of 5 mM. Anodic polarization experiments after 30 min immersion time, showed no anodic inhibition by the inhibitor in any concentration (0.1 mM - 10 mM) and at any pH. However, anodic polarization of samples immersed after longer immersion times (upto 4 days) in mildly acidic Zn2+ (pH 4) solutions showed significant reduction in anodic kinetics indicating that zinc also acts as a “slow anodic inhibitor”. In contrast to the polarization experiments, coupons exposed to inhibited acidic solutions at pH 4 showed complete suppression of dissolution of Al2CuMg particles compared to zinc-free solutions in the SEM studies. Samples exposed in pH 4 Zn2+-bearing solution exhibited highest polarization resistance which was also observed to increase with time. In deaerated solutions, the inhibition by Zn2+ at pH 4 is not observed as strongly. The ability to make the interfacial electrolyte alkaline is retarded in the absence of oxygen. As a result precipitation of Zn oxides and hydroxides was suppressed. Impedance in decarbonated chloride solutions showed that the absence of CO 2 reduces inhibition by Zn2+ at pH 4. The carbonate protective layer formed in aerated solutions is essential for providing better protection of the substrate at pH 4. Inhibitor cations were exchanged into insoluble ion-exchanging sodium bentonites and incorporated as pigments in organic coatings applied to AA 2024-T3 substrates. XRD of the pigments ensured ion exchange and UV-visible spectroscopy was used to characterize inhibitor ion release from the bentonites. Salt spray exposure tests on scribed panels were preformed and results were compared to those from SrCrO4 pigmented coatings. Zn-exchanged bentonite pigmented coatings showed better performance compared to the other exchanged bentonites when incorporated into epoxy coatings with total impedance magnitude in the same order as SrCrO4. PVB (Polyvinyl Butyral) coatings containing Zn bentonite, however, did not show superior behaviour in the impedance response due to less or no water uptake. Salt spray exposures for a period of 336 h, showed that Zn bentonite incorporated into PVB suppressed blistering compared to the neat PVB and other pigmented bentonites.
The influence of carbon nanotubes on the properties of water solutions and fresh cement pastes
NASA Astrophysics Data System (ADS)
Leonavičius, D.; Pundienė, I.; Girskas, G.; Pranckevičienė, J.; Kligys, M.; Sinica, M.
2017-10-01
It is known, that the properties of cement-based materials can be significantly improved by addition of carbon nanotubes (CNTs). The dispersion of CNTs is an important process due to an extremely high specific surface area. This aspect is very relevant and is one of the main factors for the successful use of CNTs in cement-based materials. The influence of CNTs in different amounts (from 0 to 0.5 percent) on the pH values of water solutions and fresh cement pastes, and also on rheological properties, flow characteristics, setting time and EXO reaction of the fresh cement pastes was analyzed in this work. It was found that the increment of the amount of CNTs leads to decreased pH values of water solutions and fresh cement pastes, and also increases viscosity, setting times and EXO peak times of fresh cement pastes.
Porous silicon powder as an adsorbent of heavy metal (nickel)
NASA Astrophysics Data System (ADS)
Nabil, Marwa; Motaweh, Hussien A.
2018-04-01
New and inexpensive nanoporous silicon (NPS) powder was prepared by alkali chemical etching using sonication technique and was subsequently investigated as an adsorbent in batch systems for the adsorption Ni(II) ions in an aqueous solution. The optimum conditions for the Ni(II) ion adsorption capacity of the NPS powder were studied in detail by varying parameters such as the initial Ni(II) concentration, the solution pH value, the adsorption temperature and contact time. The results indicated that the maximum adsorption capacity and the maximum removal percent of Ni(II) reached 2665.33 mg/g and 82.6%, respectively, at an initial Ni(II) concentration of 100 mg/L, adsorption time of 30 min and no effect of the solution pH and adsorption temperature.
Study on Adsorption of Chromium (VI) by Activated Carbon from Cassava Sludge
NASA Astrophysics Data System (ADS)
Yang, Jinhui; Li, Chuanshu; Yang, Bin; Kang, Sijun; Zhang, Zhen
2018-03-01
In this paper, a new type of adsorbent prepared by waste sludge from alcohol production industry was used to adsorb Cr (VI) in activated carbon from cassava sludge. A series of static adsorption experiments were carried out on the initial concentration of solution Cr (VI), pH value of solution, adsorption time and dosage of adsorbent. The results of single factor experiments show that the removal rate of Cr (VI) increases with the initial concentration of Cr(VI), while the adsorption amount is opposite. When the pH value of the solution is low, the adsorption effect of activated carbon is better.The adsorption time should be controlled within 40-60min. When the activated carbon dosage is increased, the removal rate increases but the adsorption capacity decreases.
Chemical oxidation of anthracite with hydrogen peroxide via the Fenton reaction
Heard, I.; Senftle, F.E.
1984-01-01
Solutions of 30% H2O2 ranging from pH = 0 to pH = 11.5 have been used to oxidize anthracite at room temperature. The inorganic impurities, primarily pyrite, catalysed the oxidation and reduction of H2O2 (the Fenton reaction) to form the hydroxyl radical; the oxidation of the organic matter was minimal and was observed only in strong acidic solutions (pH < 1.5). After acid demineralization, samples of the same anthracite underwent a significant enhancement of oxidation in both acid and alkaline solutions (pH = 0.4-11.5). As all the iron had been removed from the surface and the reactions were completed in a much shorter time, the oxidation mechanism must have been of a different nature than that for the untreated anthracite. A qualitative model based on the catalytic decomposition of H2O2 by activated carbon sites in the coal surface is used to explain the oxidation of the demineralized anthracite. ?? 1984.
Thompson; Parks; Brown
2000-02-15
The uptake and release behavior of cobalt(II) was studied over thousands of hours in CO(2)-free aqueous suspensions of kaolinite under three pairs of total cobalt concentration (Co(T)) and near-neutral pH (7.5-7.8) conditions. Dissolved cobalt, aluminum, and silicon concentrations were monitored by ICPMS, and cobalt-containing products were identified by EXAFS spectroscopy. In each uptake experiment, cobalt sorbed to kaolinite as a mixture of surface-adsorbed monomers or polymers and hydrotalcite-like precipitates of the approximate composition Co(x)Al(OH)(2x+2)(A(n-))(1/n), where 2=x=4 and A(n-) is nitrate or silicate anion. Precipitate stoichiometry varied with experimental conditions, with the highest Co:Al ratio in the high Co(T)/high pH experiment. Cobalt surface adsorption occurred within seconds, whereas precipitation was slower and continued for the duration of the experiments. Consequently, the proportion of precipitate in the sorbed mixture increased with time in all experiments. The most rapid precipitation occurred in the high Co(T)/high pH experiment, where solutions were most supersaturated with respect to cobalt hydrotalcite. Precipitates incorporated some previously adsorbed cobalt, as well as cobalt from solution. Cobalt release from the solid phase was effected by lowering solution pH to 7.0. Release experiments initiated after shorter sorption times returned a larger fraction of cobalt to solution than those initiated after longer sorption times, for a fixed duration of release. In other words, sorption product stability increased with sorption time. Specifically, under the conditions of the release experiments, the hydrotalcite-like precipitates are more stable than smaller adsorbates, and precipitates that formed over longer time periods are more stable than those that formed rapidly. The latter result suggests that precipitates ripened or modified their structure or composition to become more stable over the course of the several-thousand-hour sorption experiments. Precipitates that formed over hundreds of hours or longer did not dissolve over thousands of hours at the lower pH. Copyright 2000 Academic Press.
Stability of Hydrocortisone Preservative-Free Oral Solutions.
Chappe, Julie; Osman, Névine; Cisternino, Salvatore; Fontan, Jean-Eudes; Schlatter, Joël
2015-01-01
The physical and chemical stability of a preservative-free oral solution of hydrocortisone succinate was studied at different pH values and storage temperatures. Oral solutions of hydrocortisone 1 mg/mL were prepared by dissolving hydrocortisone succinate powder in citrate buffers at pH 4.0, 5.5, and 6.5, or with sterile water (pH 7.4) stored in amber glass vials. Three identical samples of the formulations were prepared and stored under refrigeration (3-7°C), ambient temperature (20-22°C) and high temperature (29-31°C). A 200-μL sample was withdrawn from each of the 3 samples immediately after preparation and at 1, 7, 14, 21, and 35 days. Samples were assayed in duplicate using stability-indicating liquid chromatography. Stability was determined by evaluating the percentage of the initial concentration remaining at each time point; stability was defined as the retention of at least 90% of the initial concentration of hydrocortisone succinate. At least 92% of the initial hydrocortisone succinate concentration in solutions pH 5.5, 6.5, and 7.4 remained throughout the 14-day study period under refrigeration. There were no detectable changes in color, odor, or pH and no visible microbial growth in these samples. In other storage conditions, hydrocortisone succinate was rapidly degraded. The hydrocortisone succinate preservative-free oral solutions at pH 5.5, 6.5, or 7.4 are chemically stable when stored under refrigeration for at least 14 days. They provide flexible and convenient dosage forms without any preservatives for pediatric patients.
Rellán-Alvarez, Rubén; Abadía, Javier; Alvarez-Fernández, Ana
2008-05-01
Nicotianamine (NA) is considered as a key element in plant metal homeostasis. This non-proteinogenic amino acid has an optimal structure for chelation of metal ions, with six functional groups that allow octahedral coordination. The ability to chelate metals by NA is largely dependent on the pK of the resulting complex and the pH of the solution, with most metals being chelated at neutral or basic pH values. In silico calculations using pKa and pK values have predicted the occurrence of metal-NA complexes in plant fluids, but the use of soft ionization techniques (e.g. electrospray), together with high-resolution mass spectrometers (e.g. time-of-flight mass detector), can offer direct and metal-specific information on the speciation of NA in solution. We have used direct infusion electrospray ionization mass spectrometry (time-of-flight) ESI-MS(TOF) to study the complexation of Mn, Fe(II), Fe(III), Ni, Cu by NA. The pH dependence of the metal-NA complexes in ESI-MS was compared to that predicted in silico. Possible exchange reactions that may occur between Fe-NA and other metal micronutrients as Zn and Cu, as well as between Fe-NA and citrate, another possible Fe ligand candidate in plants, were studied at pH 5.5 and 7.5, values typical of the plant xylem and phloem saps. Metal-NA complexes were generally observed in the ESI-MS experiments at a pH value approximately 1-2 units lower than that predicted in silico, and this difference could be only partially explained by the estimated error, approximately 0.3 pH units, associated with measuring pH in organic solvent-containing solutions. Iron-NA complexes are less likely to participate in ligand- and metal-exchange reactions at pH 7.5 than at pH 5.5. Results support that NA may be the ligand chelating Fe at pH values usually found in phloem sap, whereas in the xylem sap NA is not likely to be involved in Fe transport, conversely to what occurs with other metals such as Cu and Ni. Some considerations that need to be addressed when studying metal complexes in plant compartments by ESI-MS are also discussed.
A renaissance of soaps? - How to make clear and stable solutions at neutral pH and room temperature.
Wolfrum, Stefan; Marcus, Julien; Touraud, Didier; Kunz, Werner
2016-10-01
Soaps are the oldest and perhaps most natural surfactants. However, they lost much of their importance since "technical surfactants", usually based on sulfates or sulfonates, have been developed over the last fifty years. Indeed, soaps are pH- and salt-sensitive and they are irritant, especially to the eyes. In food emulsions, although authorized, they have a bad taste, and long-chain saturated soaps have a high Krafft temperature. We believe that most or perhaps all of these problems can be solved with modern formulation approaches. We start this paper with a short overview of our present knowledge of soaps and soap formulations. Then we focus on the problem of the lacking soap solubility at neutral pH values. For example, it is well known that with the food emulsifier sodium oleate (NaOl), clear and stable aqueous solutions can only be obtained at pH values higher than 10. A decrease in the pH value leads to turbid and unstable solutions. This effect is not compatible with the formulation of aqueous stable and drinkable formulations with neutral or even acidic pH values. However, the pH value/phase behavior of aqueous soap solutions can be altered by the addition of other surfactants. Such a surfactant can be Rebaudioside A (RebA), a steviol glycoside from the plant Stevia rebaudiana which is used as a natural food sweetener. In a recent paper, we showed the influence of RebA on the apKa value of sodium oleate in a beverage microemulsion and on its clearing temperature. In the present paper, we report on the effect of the edible bio-surfactant RebA, on the macroscopic and microscopic phase behavior of simple aqueous sodium oleate solutions at varying pH values. The macroscopic phase behavior is investigated by visual observation and turbidity measurements. The microscopic phase behavior is analyzed by acid-base titration curves, phase-contrast and electron microscopy. It turned out that even at neutral pH, aqueous NaOl/RebA solutions can be completely clear and stable for more than 50days at room temperature. This is for the first time that a long chain soap could be really solubilized in water at neutral pH at room temperature. At last, these findings were applied to prepare stable, highly translucent and drinkable aqueous solutions of omega-3-fatty acids at a pH value of 7.5. Copyright © 2016 Elsevier B.V. All rights reserved.
Recovery of niobium from irradiated targets
Phillips, Dennis R.; Jamriska, Sr., David J.; Hamilton, Virginia T.
1994-01-01
A process for selective separation of niobium from proton irradiated molybdenum targets is provided and includes dissolving the molybdenum target in a hydrogen peroxide solution to form a first ion-containing solution, contacting the first ion-containing solution with a cationic resin whereby ions selected form the group consisting of molybdenum, biobium, technetium, selenium, vanadium, arsenic, germanium, zirconium and rubidium remain in a second ion-containing solution while ions selected from the group consisting of rubidium, zinc, beryllium, cobalt, iron, manganese, chromium, strontium, yttrium and zirconium are selectively adsorbed by the cationic resin; adjusting the pH of the second ion-containing solution to within a range of from about 5.0 to about 6.0; contacting the pH adjusting second ion-containing solution with a dextran-based material for a time to selectively separate niobium from the solution and recovering the niobium from the dextran-based material.
Structures of Cu surfaces developing in benzotriazole solutions: Effect of pH
NASA Astrophysics Data System (ADS)
Kondoh, Eiichi; Kawakami, Tatsuya; Watanabe, Mitsuhiro; Jin, Linhua; Hamada, Satomi; Shima, Shohei; Hiyama, Hirokuni
2017-07-01
The effect of pH on layer formation onto clean Cu surfaces in benzotriazole (BTA) aqueous solutions was studied by in situ spectroscopic ellipsometry. The effect of H2O2 addition was also investigated. Time changes in the ellipsometric parameters Ψ and Δ, which correspond to the structural changes of the layers on Cu, were discussed. In acidic solutions, a BTA or a Cu-BTA complex layer grows directly on Cu. The out-diffusion of Cu is suppressed at the Cu layer interface. When H2O2 was mixed, the Cu surface is eroded in acidic solutions. In alkaline solutions, the BTA layer grows on the oxidized Cu layer, or no growth occurs, depending on the composition of the solutions. In neutral solutions, the Cu-BTA complex layer forms on Cu, and the uncovered part is oxidized in the presence of H2O2.
Nickheslat, Ali; Amin, Mohammad Mehdi; Izanloo, Hassan; Fatehizadeh, Ali; Mousavi, Seyed Mohammad
2013-01-01
Background. The main objective of this study was to examine the photocatalytic degradation of phenol from laboratory samples and petrochemical industries wastewater under UV radiation by using nanoparticles of titanium dioxide coated on the inner and outer quartz glass tubes. Method. The first stage of this study was conducted to stabilize the titanium dioxide nanoparticles in anatase crystal phase, using dip-coating sol-gel method on the inner and outer surfaces of quartz glass tubes. The effect of important parameters including initial phenol concentration, TiO2 catalyst dose, duration of UV radiation, pH of solution, and contact time was investigated. Results. In the dip-coat lining stage, the produced nanoparticles with anatase crystalline structure have the average particle size of 30 nm and are uniformly distributed over the tube surface. The removal efficiency of phenol was increased with the descending of the solution pH and initial phenol concentration and rising of the contact time. Conclusion. Results showed that the light easily passes through four layers of coating (about 105 nm). The highest removal efficiency of phenol with photocatalytic UV/TiO2 process was 50% at initial phenol concentration of 30 mg/L, solution pH of 3, and 300 min contact time. The comparison of synthetic solution and petrochemical wastewater showed that at same conditions the phenol removal efficiency was equal. PMID:23710198
Zheng, Xuebo; Cui, Hongbiao; Zhu, Zhenqiu; Liang, Jiani
2017-01-01
Natural biomass ash of agricultural residuals was collected from a power plant and modified with hexagonal mesoporous silica and functionalized with 3-aminopropyltriethoxysilane. The physicochemical and morphological properties of the biomass ash were analyzed by ICP-OES, SEM, TEM-EDS, FTIR, and BET analysis. The adsorption behavior of the modified product for Cd2+ in aqueous solution was studied as a function of pH, initial metal concentration, equilibrium time, and temperature. Results showed that the specific surface area of the modified product was 9 times that of the natural biomass ash. The modified biomass ash exhibited high affinity for Cd2+ and its adsorption capacity increased sharply with increasing pH from 4.0 to 6.0. The maximum adsorption capacity was 23.95 mg/g in a pH 5 solution with an initial metal concentration of 50 mg/L and a contact time of 90 min. The adsorption of Cd2+ onto the modified biomass ash was well fitted to the Langmuir model and it followed pseudo-second-order kinetics. Thermodynamic analysis results showed that the adsorption of Cd2+ was spontaneous and endothermic in nature. The results suggest that the modified biomass ash is promising for use as an inexpensive and effective adsorbent for Cd2+ removal from aqueous solution. PMID:28348509
NASA Astrophysics Data System (ADS)
Liang, Yuchen; Huang, Jie; Zang, Pengyuan; Kim, Jiyoung; Hu, Walter
2014-12-01
We report the use of molecular layer deposition (MLD) for depositing 3-aminopropyltriethoxysilane (APTES) on a silicon dioxide surface. The APTES monolayer was characterized using spectroscopic ellipsometry, contact angle goniometry, and atomic force microscopy. Effects of reaction time of repeating pulses and simultaneous feeding of water vapor with APTES were tested. The results indicate that the synergistic effects of water vapor and reaction time are significant for the formation of a stable monolayer. Additionally, increasing the number of repeating pulses improved the APTES surface coverage but led to saturation after 10 pulses. In comparing MLD with solution-phase deposition, the APTES surface coverage and the surface quality were nearly equivalent. The hydrolytic stability of the resulting films was also studied. The results confirmed that the hydrolysis process was necessary for MLD to obtain stable surface chemistry. Furthermore, we compared the pH sensing results of Si nanowire field effect transistors (Si NWFETs) modified by both the MLD and solution methods. The highly repeatable pH sensing results reflected the stability of APTES monolayers. The results also showed an improved pH response of the sensor prepared by MLD compared to the one prepared by the solution treatment, which indicated higher surface coverage of APTES.
Howell, J M
1991-11-01
Alkaline cleaning products are a cause of serious esophageal injury. Over time, legislation has diminished the concentration of many such non-industrial solutions and solids; however several products presently do not list either the pH or relative concentrations of alkaline constituents. This study measures the pHs of several non-industrial cleaning products containing either ammonium chloride, sodium hydroxide, or potassium hydroxide. Three pH measurements were performed on each of 10 non-industrial alkaline cleaning products (eight liquid, two solid). Two 0.1% ammonium chloride solutions had pHs of 12.06 +/- 0.00 and 12.06 +/- 0.01, whereas a pH of 12.43 +/- 0.00 was recorded in a 0.2% ammonium chloride solution. Concentrations of sodium hydroxide and potassium hydroxide were listed on only one of five liquid cleaning product labels. The pHs for these five products varied between 12.83 +/- 0.009 and 13.5 +/- .0.2. The pHs of three sodium hydroxide solutions differed from values reported in Micromedex (Micromedex Inc, Denver CO) by up to 0.32 pH units. Ten percent (v/v) solutions of two solid lye products had pHs of 13.62 +/- 0.008 and 13.74 +/- 0.02. The investigator found that selected non-industrial cleaning products, including ammonia solutions, retain the ability to cause clinically important esophageal damage.
Efficiency Improvement of Some Agricultural Residue Modified Materials for Textile Dyes Absorption
NASA Astrophysics Data System (ADS)
Boonsong, P.; Paksamut, J.
2018-03-01
In this work, the adsorption efficiency was investigated of some agricultural residue modified materials as natural bio-adsorbents which were rice straw (Oryza sativa L.) and pineapple leaves (Ananas comosus (L.) Merr.) for the removal of textile dyes. Reactive dyes were used in this research. The improvement procedure of agricultural residue materials properties were alkali-acid modification with sodium hydroxide solution and hydrochloric acid solution. Adsorption performance has been investigated using batch experiments. Investigated adsorption factors consisted of adsorbent dose, contact time, adsorbent materials and pH of solution. The results were found that rice straw had higher adsorption capacity than pineapple leaves. The increasing of adsorption capacity depends on adsorbent dose and contact time. Moreover, the optimum pH for dye adsorption was acidic range because lowering pH increased the positively charges on the adsorbent surface which could be attacked by negatively charge of acid dyes. The agricultural residue modified materials had significant dye removal efficiency which these adsorbents could be used for the treatment of textile effluent in industries.
Stability of alemtuzumab solutions at room temperature.
Goldspiel, Justin T; Goldspiel, Barry R; Grimes, George J; Yuan, Peng; Potti, Gopal
2013-03-01
The 24-hour stability of alemtuzumab solutions prepared at concentrations not included in the product label and stored in glass or polyolefin containers at room temperature was evaluated. Triplicate solutions of alemtuzumab (6.67, 40, and 120 μg/mL) in 0.9% sodium chloride were prepared in either glass bottles or polyolefin containers and stored at room temperature under normal fluorescent lighting conditions. The solutions were analyzed by a validated stability-indicating high-performance liquid chromatography (HPLC) assay at time zero and 8, 14, and 24 hours after preparation; solution pH values were measured and the containers visually inspected at all time points. Stability was defined as the retention of ≥90% of the initial alemtuzumab concentration. HPLC analysis indicated that the percentage of the initial alemtuzumab concentration retained was >90% for all solutions evaluated, with no significant changes over the study period. The most dilute alemtuzumab solution (6.67 μg/mL) showed some degradation (91% of the initial concentration retained at hour 24), whereas the retained concentration was >99% for all other preparations throughout the study period. Solution pH values varied by drug concentration but did not change significantly over 24 hours. No evidence of particle formation was detected in any solution by visual inspection at any time during the study. Solutions of alemtuzumab 6.67 μg/mL stored in glass bottles and solutions of 40 and 120 μg/mL stored in polyolefin containers were stable for at least 24 hours at room temperature.
The influence of storage time and pH variation on water sorption by different composite resins.
Gusmão, George Mário de Araújo Silva; De Queiroz, Thiago Vinicius Veras; Pompeu, Guilherme Ferrer; Menezes Filho, Paulo Fonseca; da Silva, Cláudio Heliomar Vicente
2013-01-01
The objective of this work was to assess the influence of storage time and pH cycling on water sorption by different composite resins. Nine resin brands were selected and divided into groups: G1-ROK (SDI), G2-ICE (SDI), G3-GLACIER (SDI), G4-Z350 (3M/ESPE), G5-Z250 (3M/ESPE), G6-TPH 3 (DENTSPLY), G7-ESTHET X (DENTSPLY), G8-SUPRAFILL (SSWHITE), and G9-MASTERFILL (BIODINΒMICS). Ninety specimens, ten per group, were obtained using an aluminum matrix. Specimens measured 10 mm diameter × 2 mm width. The groups were divided into subgroups according to the immersion solution: A - control (n = 05) stored in artificial saliva pH = 7.0 and B-test (n = 05) submitted to seven consecutive days of pH cycling (cariogenic challenger) that consisted of immersion in a pH° = 4.3 solution for 6 h followed by immersion in a pH¹ =7.0 solution for 18 h and stored in artificial saliva pH = 7.0 until the end of the experiment. The specimens were weighed on six occasions: T 0 (after fabrication), T 1 (24 h), T 2 (7 days), T 3 (15 days), T 4 (30 days), T 5 (60 days), and then analyzed. The water sorption was determined by the weight difference between the specimens at the time intervals. The mean weight gain was exactly the same for both the subgroups within group G4. The highest means for the control subgroup were found in groups: G1, G5, G7, G8, and G9. For the pH cycling subgroup, the highest means were found in G2, G3, and G6; however, significant differences between the subgroups compared to the mean-weight gain were found for G1, G5, and G7. The water sorption of composite resins is dependent upon their storage time. The pH cycling created a significant impact on resins G1, G5, and G7. The sorption and solubility of composite resins vary according to their chemical composition.
Influence of calcite and dissolved calcium on uranium(VI) sorption to a hanford subsurface sediment.
Dong, Wenming; Ball, William P; Liu, Chongxuan; Wang, Zheming; Stone, Alan T; Bai, Jing; Zachara, John M
2005-10-15
The influence of calcite and dissolved calcium on U(VI) adsorption was investigated using a calcite-containing sandy silt/clay sediment from the U. S. Department of Energy Hanford site. U(VI) adsorption to sediment, treated sediment, and sediment size fractions was studied in solutions that both had and had not been preequilibrated with calcite, at initial [U(VI)] = 10(-7)-10(-5) mol/L and final pH = 6.0-10.0. Kinetic and reversibility studies (pH 8.4) showed rapid sorption (30 min), with reasonable reversibility in the 3-day reaction time. Sorption from solutions equilibrated with calcite showed maximum U(VI) adsorption at pH 8.4 +/- 0.1. In contrast, calcium-free systems showed the greatest adsorption at pH 6.0-7.2. At pH > 8.4, U(VI) adsorption was identical from calcium-free and calcium-containing solutions. For calcite-presaturated systems, both speciation calculations and laser-induced fluorescence spectroscopic analyses indicated that aqueous U(VI) was increasingly dominated by Ca2UO2(CO3)3(0)(aq) at pH < 8.4 and thatformation of Ca2UO2(CO3)3(0)(aq) is what suppresses U(VI) adsorption. Above pH 8.4, aqueous U(VI) speciation was dominated by UO2(CO3)3(4-) in all solutions. Finally, results also showed that U(VI) adsorption was additive in regard to size fraction but not in regard to mineral mass: Carbonate minerals may have blocked U(VI) access to surfaces of higher sorption affinity.
Inorganic Substrates and Encapsulation Layers for Transient Electronics
2014-07-01
surface oxidation of the nitrides, the measurements were conducted shortly after oxide removal in buffered oxide etchant (BOE) 6:1 (Transene Company Inc...values for the time-dependent dissolution of thermally grown SiO2 (dry oxidation) in buffer solutions (black, pH 7.4; red, pH 8; blue, pH 10...22 5.1.3 Contractor will Identify and Measure Key Performance Characteristics of Candidate Metal Conductive Layers for
Lead sorption by waste biomass of hazelnut and almond shell.
Pehlivan, Erol; Altun, Türkan; Cetin, Serpil; Iqbal Bhanger, M
2009-08-15
The potential to remove Pb(2+) ion from aqueous solutions using the shells of hazelnut (HNS) (Corylus avellana) and almond (AS) (Prunus dulcis) through biosorption was investigated in batch experiments. The main parameters influencing Pb(2+) ion sorption on HNS and AS were: initial metal ion concentration, amount of adsorbent, contact time and pH value of solution. The influences of initial Pb(2+) ion concentration (0.1-1.0mM), pH (2-9), contact time (10-240 min) and adsorbent amount (0.1-1.0 g) have been investigated. Equilibrium isotherms have been measured and modelled. Adsorption of Pb(2+) ions was in all cases pH-dependent showing a maximum at equilibrium pH values between 6.0 and 7.0, depending on the biomaterial, that corresponded to equilibrium pH values of 6.0 for HNS and 7.0 for AS. The equilibrium sorption capacities of HNS and AS were 28.18 and 8.08 mg/g for lead, respectively after equilibrium time of 2h. The adsorption data fit well with the Langmuir isotherm model and the experimental result inferred that adsorption, chelation and ion exchange are major adsorption mechanisms for binding Pb(2+) ion to the sorbents.
Sedehi, Samira; Tabani, Hadi; Nojavan, Saeed
2018-03-01
In this work, polypropylene hollow fiber was replaced by agarose gel in conventional electro membrane extraction (EME) to develop a novel approach. The proposed EME method was then employed to extract two amino acids (tyrosine and phenylalanine) as model polar analytes, followed by HPLC-UV. The method showed acceptable results under optimized conditions. This green methodology outperformed conventional EME, and required neither organic solvents nor carriers. The effective parameters such as the pH values of the acceptor and the donor solutions, the thickness and pH of the gel, the extraction voltage, the stirring rate, and the extraction time were optimized. Under the optimized conditions (acceptor solution pH: 1.5; donor solution pH: 2.5; agarose gel thickness: 7mm; agarose gel pH: 1.5; stirring rate of the sample solution: 1000rpm; extraction potential: 40V; and extraction time: 15min), the limits of detection and quantification were 7.5ngmL -1 and 25ngmL -1 , respectively. The extraction recoveries were between 56.6% and 85.0%, and the calibration curves were linear with correlation coefficients above 0.996 over a concentration range of 25.0-1000.0ngmL -1 for both amino acids. The intra- and inter-day precisions were in the range of 5.5-12.5%, and relative errors were smaller than 12.0%. Finally, the optimized method was successfully applied to preconcentrate, clean up, and quantify amino acids in watermelon and grapefruit juices as well as a plasma sample, and acceptable relative recoveries in the range of 53.9-84.0% were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.
Heterogeneous selenite reduction by zero valent iron steel wool.
Li, Ziyan; Huang, Donglin; McDonald, Louis M
2017-02-01
Mine drainage from the low-sulfur surface coal mines in southern West Virginia, USA, is circumneutral (pH > 6) but contains elevated selenium (Se) concentrations. Removal of selenite ions from aqueous solutions under anoxic condition at pH 6-8.5 by zero valent iron steel wool (ZVI-SW) was investigated in bench-scale kinetic experiments using wet chemical, microscopic and spectroscopic techniques (X-ray photoelectron spectroscopy). ZVI-SW could effectively and efficiently remove Se IV from solution with pH 6-8.5. A two-step removal mechanism was identified for Se IV reduction by ZVI-SW. The proposed mechanism was electrochemical reduction of Se IV by Fe 0 in an initial lag stage, followed by a faster heterogeneous reduction, mediated by an Fe II -bearing phase (hydroxide or green rust). Solution pH was a critical factor for the kinetic rate in the lag stage (0.33 h -1 for pH > 8 and 0.10 h -1 for pH 6-8). The length of lag stage was 20-30 min as determined by the time for dissolved Fe II concentration to reach 0.30 ± 0.04 mg L -1 which was critical for induction of the faster stage. About 65% of the initial Se IV was reduced to Se 0 , the primary reductive product in both stages.
The reversibility of virus attachment to mineral surfaces
Loveland, J.P.; Ryan, J.N.; Amy, G.L.; Harvey, R.W.
1996-01-01
Virus transport through groundwater is limited by attachment to mineral surfaces and inactivation. Current virus transport models do not consider the implications of the reversibility of virus attachment to minerals. To explore the reversibility of virus attachment to mineral surfaces, we attached PRD1, a bacteriophage considered to be a good model of enteric viruses, to quartz and ferric oxyhydroxide-coated quartz surfaces over a range of pH values in equilibrium 'static columns'. Following attachment, we detached the viruses by replacing the pore solution with solutions of equal and higher pH. The extent of virus attachment followed an attachment 'edge' that occurred at a pH value about 2.5-3.5 pH units above the pH(IEP) of the mineral surfaces. Viruses attached below this edge were irreversibly attached until the pH of the detachment solution exceeded the pH value of the attachment edge. Viruses attached above this edge were reversibly attached. Derjaguin-Landau-Verwey-Overbeek (DEVO) potential energy calculations showed that the attachment edge occurred at the pH at which the potential energy of the primary minimum was near zero, implying that the position of the primary minimum (attractive or repulsive) controlled the equilibrium distribution of the viruses. The results suggest that the reversibility of virus attachment must be considered in virus transport models for accurate predictions of virus travel time.
Zr/ZrO2 sensors for in situ measurement of pH in high-temperature and -pressure aqueous solutions.
Zhang, R H; Zhang, X T; Hu, S M
2008-04-15
The aim of this study is to develop new pH sensors that can be used to test and monitor hydrogen ion activity in hydrothermal conditions. A Zr/ZrO2 oxidation electrode is fabricated for in situ pH measurement of high-temperature aqueous solutions. This sensor responds rapidly and precisely to pH over a wide range of temperature and pressure. The Zr/ZrO2 electrode was made by oxidizing zirconium metal wire with Na2CO3 melt, which produced a thin film of ZrO2 on its surface. Thus, an oxidation-reduction electrode was produced. The Zr/ZrO2 electrode has a good electrochemical stability over a wide range of pH in high-temperature aqueous solutions when used with a Ag/AgCl reference electrode. Measurements of the Zr/ZrO2 sensor potential against a Ag/AgCl reference electrode is shown to vary linearly with pH between temperatures 20 and 200 degrees C. The slope of the potential versus pH at high temperature is slightly below the theoretical value indicated by the Nernst equation; such deviation is attributed to the fact that the sensor is not strictly at equilibrium with the solution to be tested in a short period of time. The Zr/ZrO2 sensor can be calibrated over the conditions that exist in the natural deep-seawater. Our studies showed that the Zr/ZrO2 electrode is a suitable pH sensor for the hydrothermal systems at midocean ridge or other geothermal systems with the high-temperature environment. Yttria-stabilized zirconia sensors have also been used to investigate the pH of hydrothermal fluids in hot springs vents at midocean ridge. These sensors, however, are not sensitive below 200 degrees C. Zr/ZrO2 sensors have wider temperature range and can be severed as good alternative sensors for measuring the pH of hydrothermal fluids.
NASA Astrophysics Data System (ADS)
Ghaedi, Mehrorang; Kokhdan, Syamak Nasiri
2015-02-01
The use of cheep, non-toxic, safe and easily available adsorbent are efficient and recommended material and alternative to the current expensive substance for pollutant removal from wastewater. The activated carbon prepared from wood waste of local tree (millet) extensively was applied for quantitative removal of methylene blue (MB), while simply. It was used to re-used after heating and washing with alkaline solution of ethanol. This new adsorbent was characterized by using BET surface area measurement, FT-IR, pH determination at zero point of charge (pHZPC) and Boehm titration method. Response surface methodology (RSM) by at least the number of experiments main and interaction of experimental conditions such as pH of solution, contact time, initial dye concentration and adsorbent dosage was optimized and set as pH 7, contact time 18 min, initial dye concentration 20 ppm and 0.2 g of adsorbent. It was found that variable such as pH and amount of adsorbent as solely or combination effects seriously affect the removal percentage. The fitting experimental data with conventional models reveal the applicability of isotherm models Langmuir model for their well presentation and description and Kinetic real rate of adsorption at most conditions efficiently can be represented pseudo-second order, and intra-particle diffusion. It novel material is good candidate for removal of huge amount of MB (20 ppm) in short time (18 min) by consumption of small amount (0.2 g).
2013-01-01
Effect of different type of organic compounds (humic acid, oxalate, ethylenediaminetetraacetic acid, nitrilotriacetic acid, phenol) on the photocatalytic removal of cyanide with TiO2 or ZnO was studied in this work with variation of the solution pH, contact time, initial cyanide concentration and type of organic compounds. Photocatalytic oxidation efficiency of cyanide with TiO2 was greatly affected by the solution pH. It increased as the solution pH decreased. Also maximum removal of cyanide by ZnO was observed near at neutral pH because of the reduced photocatalytic activity of ZnO at exceedingly low and high pH values originated from either acidic/photochemical corrosion of the catalyst and/or surface passivation with Zn(OH)2. Removal efficiency of cyanide greatly decreased in the presence of humic acid, ethylenediaminetetraacetic acid, nitrilotriacetic acid compared to that without presence of organic compound because of the competitive oxidation as well as surface blocking by relatively large organic compounds. The oxidation pattern of cyanide was better described by first-order kinetic model. Finally photocatalytic reaction with TiO2 or ZnO can be effectively applied to treat synthetic wastewater contaminated with cyanide. PMID:24499704
Electrochemical behavior and pH stability of artificial salivas for corrosion tests.
Queiroz, Gláucia Maria Oliveira de; Silva, Leandro Freitas; Ferreira, José Tarcísio Lima; Gomes, José Antônio da Cunha P; Sathler, Lúcio
2007-01-01
It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.
Qiu, Qingyan; Wu, Jianping; Liang, Guohua; Liu, Juxiu; Chu, Guowei; Zhou, Guoyi; Zhang, Deqiang
2015-05-01
Acid rain is an environmental problem of increasing concern in China. In this study, a laboratory leaching column experiment with acid forest soil was set up to investigate the responses of soil and soil solution chemistry to simulated acid rain (SAR). Five pH levels of SAR were set: 2.5, 3.0, 3.5, 4.0, and 4.5 (as a control, CK). The results showed that soil acidification would occur when the pH of SAR was ≤3.5. The concentrations of NO₃(-)and Ca(2+) in the soil increased significantly when the pH of SAR fell 3.5. The concentration of SO₄(2-) in the soil increased significantly when the pH of SAR was <4.0. The effects of SAR on soil solution chemistry became increasingly apparent as the experiment proceeded (except for Na(+) and dissolved organic carbon (DOC)). The net exports of NO₃(-), SO₄(2-), Mg(2+), and Ca(2+) increased about 42-86% under pH 2.5 treatment as compared to CK. The Ca(2+) was sensitive to SAR, and the soil could release Ca(2+) through mineral weathering to mitigate soil acidification. The concentration of exchangeable Al(3+) in the soil increased with increasing the acidity of SAR. The releases of soluble Al and Fe were SAR pH dependent, and their net exports under pH 2.5 treatment were 19.6 and 5.5 times, respectively, higher than that under CK. The net export of DOC was reduced by 12-29% under SAR treatments as compared to CK. Our results indicate the chemical constituents in the soil are more sensitive to SAR than those in the soil solution, and the effects of SAR on soil solution chemistry depend not only on the intensity of SAR but also on the duration of SAR addition. The soil and soil solution chemistry in this region may not be affected by current precipitation (pH≈4.5) in short term, but the soil and soil leachate chemistry may change dramatically if the pH of precipitation were below 3.5 and 3.0, respectively.
Ma, Li Ying; Wang, Huai You; Xie, Hui; Xu, Li Xiao
2004-07-01
The fluorescence property of fluorescein isothiocyanate (FITC) in acid-alkaline medium was studied by spectrofluorimetry. The characteristic of FITC response to hydrogen ion has been examined in acid-alkaline solution. A novel pH chemical sensor was prepared based on the relationship between the relative fluorescence intensity of FITC and pH. The measurement of relative fluorescence intensity was carried out at 362 nm with excitation at 250 nm. The excellent linear relationship was obtained between relative fluorescence intensity and pH in the range of pH 1-5. The linear regression equation of the calibration graph is F = 66.871 + 6.605 pH (F is relative fluorescence intensity), with a correlation coefficient of linear regression of 0.9995. Effects of temperature, concentration of FITC on the response to hydrogen ion had been examined. It was important that this chemical sensor was long lifetime, and the property of response to hydrogen ion was stable for at least 70 days. This pH sensor can be used for measuring pH value in water solution. The accuracy is 0.01 pH unit. The results obtained by the pH sensor agreed with those by the pH meter. Obviously, this pH sensor is potential for determining pH change real time in biological system.
NASA Astrophysics Data System (ADS)
Ma, Li Ying; Wang, Huai You; Xie, Hui; Xu, Li Xiao
2004-07-01
The fluorescence property of fluorescein isothiocyanate (FITC) in acid-alkaline medium was studied by spectrofluorimetry. The characteristic of FITC response to hydrogen ion has been examined in acid-alkaline solution. A novel pH chemical sensor was prepared based on the relationship between the relative fluorescence intensity of FITC and pH. The measurement of relative fluorescence intensity was carried out at 362 nm with excitation at 250 nm. The excellent linear relationship was obtained between relative fluorescence intensity and pH in the range of pH 1-5. The linear regression equation of the calibration graph is F=66.871+6.605 pH ( F is relative fluorescence intensity), with a correlation coefficient of linear regression of 0.9995. Effects of temperature, concentration of FITC on the response to hydrogen ion had been examined. It was important that this chemical sensor was long lifetime, and the property of response to hydrogen ion was stable for at least 70 days. This pH sensor can be used for measuring pH value in water solution. The accuracy is 0.01 pH unit. The results obtained by the pH sensor agreed with those by the pH meter. Obviously, this pH sensor is potential for determining pH change real time in biological system.
Amp Synthesis in Aqueous Solution of Adenosine and Phosphorus Pentoxide
NASA Astrophysics Data System (ADS)
Yamagata, Y.; Kojima, H.; Ejiri, K.; Inomata, K.
1982-12-01
Possible formation of a P4O10 molecule in magma, the stability of the molecule in hydrous volcanic gas at high temperatures and a possible prebiotic phosphate cycle were discussed in relation to chemical evolution. To demonstrate the utility of phosphorus pentoxide as a phosphorylating agent, aqueous solutions of adenosine (0.02M) and phosphorus pentoxide (0.2M) were incubated at 37°C for 5 months. The pH of the solutions was adjusted every day or every few days to each fixed value (9.0, 10.5, 11.5, 12.5) with 10 N NaOH. The HPLC analysis showed the formation of 2'-AMP, 3'-AMP, 5'-AMP, cyclic (2' 3')-AMP and cyclic (3' 5')-AMP. The main components of the products were 2'- and 3'-AMP, though cyclic (2' 3')-AMP was the main component in the early period of the incubation at pH 9.0. The yields (conversion rate of adenosine to AMPs) were increased almost linearly with the incubation time for 5 months in the case of pH 9.0. The final yields were about 3% (pH 9.0), 6% (pH 9.0, 1 M NaCl), 5% (pH 9.0, 0.01 M CaCl2, 0.01 M MgCl2), 7% (pH 9.0, 0.5 M NaCl, 0.01 M CaCl2, 0.01 M MgCl2), 9% (pH 9.0, 1 M NaCl, 0.01 M CaCl2, 0.01 M MgCl2), 32% (pH 10.5), 43% (pH 11.5), 35% (pH 12.5).
Horng, Richard S; Tseng, I-Chin
2008-06-15
This study examines a water-based system, coupling an adsorber and a photoreactor, for regeneration of granular activated carbon (GAC) saturated with acetone and isopropyl alcohol (IPA). Through water recirculation the regeneration reaction was operated in both intermittent and continuous ultraviolet illumination modes. With a periodic dosage of hydrogen peroxide not only was regeneration efficient but it was also catalyzed by GAC in the adsorber. The concentrations of acetone, solution chemical oxygen demand (COD), pH and organic residues on GAC surfaces were measured during regenerations. Both pH and solution COD were found to correlate with regeneration completion as measured by organic residue on GAC surfaces in four regeneration cycles with acetone. Solution pH decreased to the acidic values and then returned to near its original value when organic residues were 0.085-0.255 mg/g GAC, that is, destruction efficiency of adsorbed acetone on the GAC surface was more than 99%. Likewise, solution COD became low (<100 mg/l) at regeneration completion. The pH variation pattern was then applied to another four cycles of regeneration with IPA, and successfully reflected the timing of complete regeneration. The final levels of organic residue on GAC surfaces were between 0.135 and 0.310 mg/g GAC in each of four regeneration cycles, each of which had been stopped based on the measurements of pH and solution COD. Furthermore, nearly the same batch of GAC could be repeatedly used with little changes in physicochemical properties in each of eight cycles: adsorptive capacities were 95+/-7 mg acetone/g GAC and 87+/-3 mg IPA/g GAC, and breakthrough time was 0.86+/-0.05 for acetone and 0.78+/-0.03 h for IPA. An economic assessment of the system showed that the operating cost was about 0.04 USD for treating every gram of acetone in the air.
Wang, Yu; Mu, Ya-bing; Miao, Lei-ying; Sun, Hong-chen; Li, Cheng-ku
2007-03-01
To study the methods of decalcification for making united slices of tooth and affiliated periodontic tissues. Twenty-one samples containing dog molars and affiliated periodontic tissues were divided into seven mean groups. The pH value of solution, time of decalcification, weight and volume of samples, and content of decalcified calcium were detected. The slices were observed by HE, specific, and immunohistochemical stain. The velocity of decalcification increased with decrease of solution pH. The weight of samples lightened by 37.61%, the volume reduced by 25.97% on average, and calcium decalcified was 174.49 mg per gram humid samples. The EDTA decalcification was slowest, but it was best. Decalcification was fast in Plank-Rycho solution while the section was worst, and faster in the formyl solution containing aluminium chloride than in EDTA, and the section was better. The 50% formyl solution containing aluminium chloride is an ideal decalcifying solution.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., readable to 0.01 g or better. 3.2pH meter, standardized to pH 4.0 with pH 4.0 buffer and pH 7 with pH 7.0... N sodium hydroxide solution. 4.2Hydroxylamine hydrochloride solution, 100 grams per liter, pH... stirrer. Confirm that the resin has dissolved. 5.4Adjust the resin/solvent solution to pH 4.0, using the...
Complexing Agents and pH Influence on Chemical Durability of Type I Molded Glass Containers.
Biavati, Alberto; Poncini, Michele; Ferrarini, Arianna; Favaro, Nicola; Scarpa, Martina; Vallotto, Marta
2017-01-01
Among the factors that affect the glass surface chemical durability, pH and complexing agents present in aqueous solution have the main role. Glass surface attack can be also related to the delamination issue causing glass particles' appearance in the pharmaceutical preparation. A few methods to check for glass containers delamination propensity and some control guidelines have been proposed. The present study emphasizes the possible synergy between a few complexing agents with pH on borosilicate glass chemical durability.Hydrolytic attack was performed in small-volume 23 mL type I glass containers autoclaved according to the European Pharmacopoeia or United States Pharmacopeia for 1 h at 121 °C, in order to enhance the chemical attack due to time, temperature, and the unfavorable surface/volume ratio. Solutions of 0.048 M or 0.024 M (M/L) of the acids citric, glutaric, acetic, EDTA (ethylenediaminetetraacetic acid), together with sodium phosphate with water for comparison, were used for the trials. The pH was adjusted ±0.05 units at fixed values 5.5, 6.6, 7, 7.4, 8, and 9 by LiOH diluted solution.Because silicon is the main glass network former, silicon release into the attack solutions was chosen as the main index of the glass surface attack and analysed by inductively coupled plasma atomic emission spectrophotometry. The work was completed by the analysis of the silicon release in the worst attack conditions of molded glass, soda lime type II glass, and tubing borosilicate glass vials to compare different glass compositions and forming technologies. Surface analysis by scanning electron microscopy was finally performed to check for the surface status after the worst chemical attack condition by citric acid. LAY ABSTRACT: Glass, like every packaging material, can have some usage limits, mainly in basic pH solutions. The issue of glass surface degradation particles that appear in vials (delamination) has forced a number of drug product recalls in recent years. To prevent such situations, pharmaceutical and biopharmaceutical manufacturers need to understand the reasons for accelerate surface glass corrosion mainly in the case of injectables.Some drugs can contain active components with known ability to corrode glass silica networks. Sometimes these ingredients are dissolved in an alkaline medium that dramatically increases the glass corrosion and potentially causes the issue. As this action is strongly affected by time and temperature, flaking may become visible only after a long storage time. The purpose of this investigation is to verify the borosilicate glass chemical durability during controlled conditions of time and temperature when in contact with testing solutions containing different complexing agents by varying the pH. Si concentration in the extract solution is taken as an index of glass dissolution during constant autoclaving conditions for 1 h at 121 °C, which simulates approximately five years of contact at room temperature.Acetate, citrate, ethylenediaminetetraacetic acid (EDTA), phosphate, and glutarate 0.048 M or 0.024 M solutions were used at increasing pH from 5.5 to 9.0. The chemical durability of two borosilicate tubing glass vials of different glass compositions were compared with the molded one in the worst attack conditions by citric acid. Even if no delamination issue has been experienced by this study in type I molded and tubing containers, the conclusions developed can provide pharmaceutical manufacturers with useful information to prevent glass delamination risk in their processes. © PDA, Inc. 2017.
Topical drug delivery to the eye: dorzolamide.
Loftsson, Thorsteinn; Jansook, Phatsawee; Stefánsson, Einar
2012-11-01
Topically applied carbonic anhydrase inhibitors (CAIs) in eye drop solutions are commonly used to treat glaucoma. However, local eye irritation and multiple daily administrations may hamper their clinical usefulness. Aqueous eye drop formulations that improve their topical bioavailability and reduce their eye irritation can improve their clinical efficacy. Earlier studies showed that dorzolamide and closely related CAIs are more effectively delivered into the eye from acidic eye drop solutions than from comparable neutral solutions. Consequently, dorzolamide was marketed as an aqueous pH 5.6 eye drop solution (Trusopt(®) , Merck). Later, it was shown that increasing the pH of the eye drops from pH 5.6 to physiologic pH significantly reduced their local irritation. Earlier attempts to use cyclodextrins (CDs) as ocular penetration enhancers in dorzolamide eye drop solutions failed since; although the CDs were able to enhance the aqueous solubility of dorzolamide, increasing the pH from 5.6 to physiologic pH reduced the ability of the drug to permeate into the eye. Later, it was discovered that formulating the drug as aqueous dorzolamide/γCD eye drop microparticle suspension resulted in significant bioavailability enhancement. The solid dorzolamide/γCD microparticles are mucoadhesive and release dorzolamide into the aqueous tear fluid for extended time period. Consequently, sustained high dorzolamide concentrations in aqueous humour and various eye tissues were observed after single administration of the aqueous dorzolamide/γCD eye drop microsuspension. The microsuspension has a potential of being developed into a once-a-day eye drop product. This article reviews the physicochemical properties of dorzolamide, its permeation characteristics and topical bioavailability. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Chen, Haiyong; Wang, Jing; Shan, Duoliang; Chen, Jing; Zhang, Shouting; Lu, Xiaoquan
2018-05-15
pH plays an important role in understanding physiological/pathologic processes, and abnormal pH is a symbol of many common diseases such as cancer, stroke, and Alzheimer's disease. In this work, an effective dual-emission fluorescent metal-organic framework nanocomposite probe (denoted as RB-PCN) has been constructed for sensitive and broad-range detection of pH. RB-PCN was prepared by encapsulating the DBI-PEG-NH 2 -functionalized Fe 3 O 4 into Zr-MOFs and then further reacting it with rhodamine B isothiocyanates (RBITC). In RB-PCN, RBITC is capable of sensing changes in pH in acidic solutions. Zr-MOFs not only enrich the target analyte but also exhibit a fluorescence response to pH changes in alkaline solutions. Based on the above structural and compositional features, RB-PCN could detect a wide range of pH changes. Importantly, such a nanoprobe could "see" the intracellular pH changes by fluorescence confocal imaging as well as "measure" the wider range of pH in actual samples by fluorescence spectroscopy. To the best of our knowledge, this is the first time a MOF-based dual-emitting fluorescent nanoprobe has been used for a wide range of pH detection.
The study of ikaite formation in sea ice
NASA Astrophysics Data System (ADS)
Hu, Y.; Nehrke, G.; Dieckmann, G.; Völker, C.; Wolf-Gladrow, D.
2012-04-01
Ikaite (CaCO3.6H2O) is a metastable mineral of calcium carbonate, which is usually found in environments characterized by low temperature (below 5° C), high pH, high alkalinity, high concentration of phosphate and organic matter. Although synthetic CaCO3.6H2O was already known from laboratory studies in 1865, ikaite was first observed in nature in 1963. Recently, Dieckmann et al. (2008, 2010) discovered this mineral in sea ice, which at the same time, was the first direct proof of CaCO3 precipitation in sea ice. However, little is known about the mechanism of ikaite formation in sea ice. Our study focuses on how physico-chemical processes in sea ice affect the formation of ikaite. Experiments were set up at pH ranging from 8.5 to 9.0, and salinity ranging from 0 to 105 at 0 ° C, in order to examine the effect of pH, salinity and also phosphate on the formation of ikaite. Preliminary results read: (1) Experiments show that ikaite can form at different pH levels (8.5~9.0). At high pH, the induction time (the time when the crystals start to precipitate) is shorter which means high pH favours the formation of ikaite. This might be expected given higher CO32- concentrations and thus higher saturation levels for ikaite with increasing pH. (2) The results of experiments with different salinities show that ikaite can form over wide range of salinities from 0 to 105 both in Artificial Sea Water (ASW) and NaCl solution in the presence of phosphate. In ASW, the induction time increases with salinity from S = 0 to S =105; while in NaCl solution, the induction time first increases with salinity and then decreases with the further increase of salinity. Salinity plays both positive and negative roles in the formation of ikaite. On the one hand, the increase in salinity will increase the fraction of CO32- in DIC. On the other hand, the increase in salinity means more ions are involved in the solution, which will reduce the activities of Ca2+ and CO32-by forming ion pairs with them. This effect is more obvious in ASW, as there are more ion species in ASW than in the NaCl solution. (3) The effect of different phosphate concentrations at high salinity (S = 70) medium show that in ASW, the precipitate is ikaite both with and without the presence of phosphate. In NaCl solution, the precipitate is ikaite in the presence of phosphate; however, the precipitate is no longer ikaite but vaterite in the absence of phosphate. These results suggest phosphate plays an important role in the formation of ikaite. However, besides phosphate, there must be other ion(s) in ASW, which also favour the formation of ikaite.
NASA Astrophysics Data System (ADS)
Bauld, Reg; Hesari, Mahdi; Workentin, Mark S.; Fanchini, Giovanni
2014-06-01
We report for the first time the fabrication of nanocomposite hole-blocking layers consisting of poly-3,4-ethylene-dioxythiophene:poly-styrene-sulfonate (PEDOT:PSS) thin films incorporating networks of gold nanoparticles assembled from Au144(SCH2CH2Ph)60, a molecular gold precursor. These thin films can be prepared reproducibly on indium tin oxide by spinning on it Au144(SCH2CH2Ph)60 solutions in chlorobenzene, annealing the resulting thin film at 400 °C, and subsequently spinning PEDOT:PSS on top. The use of our nanocomposite hole-blocking layers for enhancing the photoconversion efficiency of bulk heterojunction organic solar cells is demonstrated. By varying the concentration of Au144(SCH2CH2Ph)60 in the starting solution and the annealing time, different gold nanostructures were obtained ranging from individual gold nanoparticles (AuNPs) to tessellated networks of gold nanostructures (Tess-AuNPs). Improvement in organic solar cell efficiencies up to 10% relative to a reference cell is demonstrated with Tess-AuNPs embedded in PEDOT:PSS.
Ferreira, Thania Alexandra; Rodriguez, Jose Antonio; Paez-Hernandez, María Elena; Guevara-Lara, Alfredo; Barrado, Enrique; Hernandez, Prisciliano
2017-01-01
An evaluation of the chromium(VI) adsorption capacity of four magnetite sorbents coated with a polymer phase containing polymethacrylic acid or polyallyl-3-methylimidazolium is presented. Factors that influence the chromium(VI) removal such as solution pH and contact time were investigated in batch experiments and in stirred tank reactor mode. Affinity and rate constants increased with the molar ratio of the imidazolium. The highest adsorption was obtained at pH 2.0 due to the contribution of electrostatic interactions. PMID:28772865
Corrosion protection of galvanized steels by silane-based treatments
NASA Astrophysics Data System (ADS)
Yuan, Wei
The possibility of using silane coupling agents as replacements for chromate treatments was investigated on galvanized steel substrates. In order to understand the influence of deposition parameters on silane film formation, pure zinc substrates were first used as a model for galvanized steel to study the interaction between silane coupling agents and zinc surfaces. The silane films formed on pure zinc substrates from aqueous solutions were characterized by ellipsometry, contact angle measurements, reflection absorption infrared spectroscopy, x-ray photoelectron spectroscopy, and atomic force microscopy. The deposition parameters studied include solution concentration, solution dipping time and pH value of the applied solution. It appears that silane film formation involved a true equilibrium of hydrolysis and condensation reactions in aqueous solutions. It has been found that the silane film thickness obtained depends primarily on the solution concentration and is almost independent of the solution dipping time. The molecular orientation of applied silane films is determined by the pH value of applied silane solutions and the isoelectric point of metal substrates. The deposition window in terms of pH value for zinc substrates is between 6.0 and 9.0. The total surface energy of the silane-coated pure zinc substrates decreases with film aging time, the decrease rate, however, is determined by the nature of silane coupling agents. Selected silane coupling agents were applied as prepaint or passivation treatments onto galvanized steel substrates. The corrosion protection provided by these silane-based treatments were evaluated by salt spray test, cyclic corrosion test, electrochemical impedance spectroscopy, and stack test. The results showed that silane coupling agents can possibly be used to replace chromates for corrosion control of galvanized steel substrates. Silane coatings provided by these silane treatments serve mainly as physical barriers. Factors that affect the performance of a silane coupling agent in the application of corrosion control include chemical reactivity, hydrophobic character, siloxane crosslinker network, and film thickness. Good protections afforded by the silane treatments are a synergetic effect of all these factors.
Removal of inorganic mercury from aquatic environments by multi-walled carbon nanotubes.
Yaghmaeian, Kamyar; Khosravi Mashizi, Reza; Nasseri, Simin; Mahvi, Amir Hossein; Alimohammadi, Mahmood; Nazmara, Shahrokh
2015-01-01
Mercury is considered as a toxic heavy metal in aquatic environments due to accumulation in bodies of living organisms. Exposure to mercury may lead to different toxic effects in humans including damages to kidneys and nervous system. Multi-walled carbon nanotubes (MWCNTs) were selected as sorbent to remove mercury from aqueous solution using batch technique. ICP instrument was used to determine the amount of mercury in solution. Moreover, pH, contact time and initial concentration of mercury were studied to determine the influence of these parameters on the adsorption conditions. Results indicate that the adsorption strongly depended on pH and the best pH for adsorption is about 7. The rate of adsorption process initially was rapid but it was gradually reduced with increasing of contact time and reached the equilibrium after 120 min. In addition, more than 85 % of initial concentration of 0.1 mg/l was removed at 0.5 g/l concentration of sorbent and contact time of 120 min. Meanwhile, the adsorption process followed the pseudo second-order model and the adsorption isotherms could be described by both the Freundlich and the Langmuir models. This study showed that MWCNTs can effectively remove inorganic mercury from aqueous solutions as adsorbent.
NASA Astrophysics Data System (ADS)
Ishii, Marina; Kunimura, Juliana Sayuri; Jeng, Hélio Tallon; Vessoni Penna, Thereza Christina; Cholewa, Olivia
The thermal stability of recombinant green fluorescent protein (GFP) in sodium chloride (NaCl) solutions at different concentrations, pH, and temperatures was evaluated by assaying the loss of fluorescence intensity as a measure of denaturation. GFP, extracted from Escherichia coli cells by the three-phase partitioning method and purified through a butyl hydrophobic interaction chromatography (HIC) column, was diluted in water for injection (WFI) (pH 6.0-7.0) and in 10 mM buffer solutions (acetate, pH 5.0; phosphate, pH 7.0; and Tris-EDTA, pH 8.0) with 0.9-30% NaCl or without and incubated at 80-95°C. The extent of protein denaturation was expressed as a percentage of the calculated decimal reduction time (D-value). In acetate buffer (pH 4.84 ±0.12), the mean D-values for 90% reduction in GFP fluorescence ranged from 2.3 to 3.6 min, independent of NaCl concentration and temperature. GFP thermal stability diluted in WFI (pH 5.94±0.60) was half that observed in phosphate buffer (pH 6.08±0.60); but in both systems, D-values decreased linearly with increasing NaCl concentration, with D-values (at 80°C) ranging from 3.44, min (WFI) to 6.1 min (phosphate buffer), both with 30% NaCl. However, D-values in Tris-EDTA (pH 7.65±0.17) were directly dependent on the NaCl concentration and 5-10 times higher than D-values for GFP in WFI at 80°C. GFP pH-and thermal stability can be easily monitored by the convenient measure of fluorescence intensity and potentially be used as an indicator to monitor that processing times and temperatures were attained.
Klovrzová, Sylva; Zahálka, Lukáš; Matysová, Ludmila; Horák, Petr; Sklubalová, Zdenka
2013-02-01
The aim of this study is to formulate an extemporaneous pediatric oral solution of propranolol hydrochloride (PRO) 2 mg/ml for the therapy of infantile haemangioma or hypertension in a target age group of 1 month to school children and to evaluate its stability. A citric acid solution and/or a citrate-phosphate buffer solution, respectively, were used as the vehicles to achieve pH value of about 3, optimal for the stability of PRO. In order to mask the bitter taste of PRO, simple syrup was used as the sweetener. All solutions were stored in tightly closed brown glass bottles at 5 ± 3 °C and/or 25 ± 3 °C, respectively. The validated HPLC method was used to evaluate the concentration of PRO and a preservative, sodium benzoate, at time intervals of 0-180 days. All preparations were stable at both storage temperatures with pH values in the range of 2.8-3.2. According to pharmacopoeial requirements, the efficacy of sodium benzoate 0.05 % w/v was proved (Ph.Eur., 5.1.3). The preparation formulated with the citrate-phosphate buffer, in our experience, had better palatability than that formulated with the citric acid solution. propranolol hydrochloride pediatric preparation extemporaneous preparation solution stability testing HPLC.
Das, B Kumar; Kim, Ji Gang; Choi, Ji Weon
2011-10-01
The role of different washing solutions and contact times was investigated to determine their use as potential sanitizers for maintaining the microbial quality and food safety of fresh-cut paprika. Samples were cut into small pieces, washed for both 90 and 180 s by different washing solutions: tap water, chlorinated water (100 mg/L and pH 6.5-7), electrolyzed water (pH 7.2) and ozonized water (4 mg/L). Then, samples were packaged in 50 µm polypropylene bags and stored at 5 °C for 12 days, followed by an evaluation of the antimicrobial efficacy of the treatments. Various quality and safety parameters, such as gas composition, color, off-odor, electrical conductivity and microbial numbers, were evaluated during storage. Results revealed insignificant differences in gas composition, and no off-odor was observed in any of the samples during the storage period. However, longer contact time resulted in slightly lower hue angle value than a short one for all washing solutions. Moreover, samples washed with ozone washings showed lower electrolyte leakage than other washing solutions. Samples washed for longer contact time except those washed in ozonized water showed increased microbial numbers during storage. Hence, it has been concluded that longer contact time with ozone has positive effects, whereas the other washing solutions adversely affect the microbial quality and safety aspects of fresh-cut paprika.
Long-term conversion of 45S5 bioactive glass-ceramic microspheres in aqueous phosphate solution.
Fu, Hailuo; Rahaman, Mohamed N; Day, Delbert E; Huang, Wenhai
2012-05-01
The conversion of 45S5 glass and glass-ceramics to a hydroxyapatite (HA)-like material in vitro has been studied extensively, but only for short reaction times (typically <3 months). In this paper, we report for the first time on the long-term conversion of 45S5 glass-ceramic microspheres (designated 45S5c) in an aqueous phosphate solution. Microspheres of 45S5c (75-150 μm) were immersed for 10 years at room temperature (~25 °C) in K(2)HPO(4) solution with a concentration of 0.01 M or 1.0 M, and with a starting pH of 7.0 or 9.5. The reacted 45S5c microspheres and solutions were analyzed using structural and analytical techniques. Only 25-45 vol% of the 45S5c microspheres were converted to an HA-like material after the 10 year reaction. In solutions with a starting pH of 9.5, an increase in the K(2)HPO(4) concentration from 0.01 to 1.0 M resulted in a doubling of the volume of the microspheres converted to an HA-like material but had little effect on the composition of the HA-like product. In comparison, reaction of the 45S5c microspheres in the solution with a starting pH of 7.0 resulted in an HA-like product in the 0.01 M K(2)HPO(4) solution but a calcium pyrophosphate product, Ca(10)K(4)(P(2)O(7))(6).9H(2)O, in the 1.0 M solution. The consequences of these results for the long-term use of 45S5 glass-ceramics in biomedical applications are discussed.
Physiochemical properties of experimental nano-hybrid MTA
Akhavan Zanjani, V; Tabari, K; Sheikh-Al-Eslamian, SM; Abrandabadi, AN
2017-01-01
Introduction: Development of new pulp capping agents has paved the way towards the preservation of pulp vitality, which is an important goal in restorative dentistry. This study sought to assess the calcium ion release, pH and setting of mineral trioxide aggregate (MTA) Angelus, an experimental formulation of nano-hybrid MTA containing nano-SiO2, nano-Al2O3 and nano-TiO2 and MTA Angelus plus nano-oxides. Methods: In this experimental study, five specimens from each material were placed in polypropylene tubes and immersed in a flask containing deionized distilled water. The quantity of calcium ions released into the solution from each material was measured at 15 minutes, one hour, and 24 hours by using atomic absorption spectroscopy. The pH of the solutions was measured by using a pH meter at the respective time points. The setting time was also assessed by using a Gilmore needle. Data were analyzed by using repeated measure ANOVA. Results: The quantity of released calcium ions was not significantly different among the groups (P=0.060). All materials were alkaline and the pH at 24 hours was significantly higher than the other two time points in all groups (P<0.001). The experimental group had the shortest and the MTA Angelus had the longest setting time. All materials were alkaline and capable of releasing calcium. Addition of nanoparticles to MTA Angelus significantly decreased the setting time but had no effect on the release of calcium ions or pH. Abbreviations: MTA = mineral trioxide aggregate, VPT = vital pulp therapy PMID:29075348
Postrigor citric acid enhancement can alter cooked color but not fresh color of dark-cutting beef.
Stackhouse, R J; Apple, J K; Yancey, J W S; Keys, C A; Johnson, T M; Mehall, L N
2016-04-01
In 2 experiments, dark-cutting (DC) beef strip loins were used to test the effects of citric acid-enhancement pH on visual and instrumental color of fresh and cooked steaks. In Exp. 1 and 2, each DC (mean pH = 6.57 and 6.65, respectively) and normal-pH, low USDA Choice (CH; mean pH = 5.48 and 5.51, respectively) strip loin was cut into 2 equal-length sections, and DC sections were injected to 111% of raw section weight with pH 3.5 to 5.0 (Exp. 1) or pH 2.0 to 3.5 (Exp. 2) solutions made by mixing citric acid in either 0.05% orthophosphate (PO) solution or tap water (HO) base solutions (Exp. 1) and 0.5% PO or 0.5% tripolyphosphate solution base solutions (Exp. 2). After enhancement, sections were cut into steaks, which were assigned to either 5 d of simulated retail display or cooked to 71°C for cooked color measurement. Postenhancement pH of DC steaks enhanced with pH 3.5 to 5.0 solutions did not ( ≥ 0.180) differ from that of nonenhanced DC steaks (Exp. 1) but linearly decreased ( < 0.001) as solution pH decreased from 3.5 to 2.0 (Exp. 2). Even though fresh color scores were increased ( < 0.001) by citric acid enhancement over untreated DC steaks during the first 3 d of display, fresh steak color never ( < 0.001) approached that of nonenhanced CH steaks. When compared with nonenhanced DC steaks, enhancement with pH 3.5 to 5.0 solutions received lower cooked color scores, whereas enhancing DC sections with pH 2.5 solutions produced cooked color and degree-of-doneness scores similar ( ≥ 0.113) to those of nonenhanced CH steaks (Exp. 2). Results indicated that the pH of citric acid enhancement solutions, regardless of base solution, were insufficient to improve the fresh color of DC beef; however, enhancement with pH 2.5 citric acid solutions effectively eliminated the persistent red cooked color typically associated with DC beef comparable with that of normal-pH beef.
Qin, Yiheng; Alam, Arif U; Pan, Si; Howlader, Matiar M R; Ghosh, Raja; Selvaganapathy, P Ravi; Wu, Yiliang; Deen, M Jamal
2016-01-01
Highly sensitive, easy-to-fabricate, and low-cost pH sensors with small dimensions are required to monitor human bodily fluids, drinking water quality and chemical/biological processes. In this study, a low-temperature, solution-based process is developed to prepare palladium/palladium oxide (Pd/PdO) thin films for pH sensing. A precursor solution for Pd is spin coated onto pre-cleaned glass substrates and annealed at low temperature to generate Pd and PdO. The percentages of PdO at the surface and in the bulk of the electrodes are correlated to their sensing performance, which was studied by using the X-ray photoelectron spectroscope. Large amounts of PdO introduced by prolonged annealing improve the electrode's sensitivity and long-term stability. Atomic force microscopy study showed that the low-temperature annealing results in a smooth electrode surface, which contributes to a fast response. Nano-voids at the electrode surfaces were observed by scanning electron microscope, indicating a reason for the long-term degradation of the pH sensitivity. Using the optimized annealing parameters of 200°C for 48 h, a linear pH response with sensitivity of 64.71±0.56 mV/pH is obtained for pH between 2 and 12. These electrodes show a response time shorter than 18 s, hysteresis less than 8 mV and stability over 60 days. High reproducibility in the sensing performance is achieved. This low-temperature solution-processed sensing electrode shows the potential for the development of pH sensing systems on flexible substrates over a large area at low cost without using vacuum equipment. Copyright © 2015 Elsevier B.V. All rights reserved.
Takenaka, Norimichi; Tanaka, Masayuki; Okitsu, Kenji; Bandow, Hiroshi
2006-09-14
Oxidative decomposition of gallic acid occurs in alkaline solutions but hardly arises in acidic solutions. We have found that the addition of sodium chloride promotes the decomposition of gallic acid caused by freezing even under neutral and acidic conditions. Even at pH 4.5, gallic acid was decomposed by freezing in the presence of NaCl; however, in the absence of NaCl, it was hardly decomposed by freezing at pH lower than 7. Chloride ions are more easily incorporated in ice than sodium ions when the NaCl solution is frozen. The unfrozen solution in ice becomes positively charged, and as a result, protons transfer from the unfrozen solution to the ice. We measured the pH in the unfrozen solution which coexists with single-crystal ice formed from a 5 mmol dm(-3) NaCl solution and determined the pH to be 8.6 at equilibrium with CO(2) of 380 ppm or 11.3 in the absence of CO(2) compared to pH 5.6 in the original solution. From the model calculation performed for gallic acid solution in the presence of 5 mmol dm(-3) NaCl, it can be estimated that the amount of OH(-) transferred from the ice to the solution corresponds to 1.26 x 10(-5) mol dm(-3). The amount of OH(-) transferred is concentrated into the unfrozen solution and affects the pH of the unfrozen solution. Therefore, the pH in an unfrozen gallic acid solution in ice becomes alkaline, and the decomposition of gallic acid proceeds. It is expected that other base-catalyzed reactions in weakly acidic solutions also proceed by freezing in the presence of NaCl without the need for any alkaline reagents.
Karaibrahimoglu, Yildiz; Fan, Xuetong; Sapers, Gerald M; Sokorai, Kimberly
2004-04-01
Fresh-cut apple slices were dipped in calcium ascorbate (CaA) solution at pH values ranging from 2.5 to 7.0 to inhibit browning. After treatment, the cut apples were stored at 4 and 10 degrees C for up to 21 days. Color and texture of the apples were determined on days 1, 14, and 21. In a separate experiement, the pH of CaA solution was adjusted with acetic acid to six different pH levels, and the solution was inoculated with Listeria innocua. The survival of the bacterium and the stability of CaA were determined at 0, 20, and 96 h. The cut apples maintained fresh quality when the pH of the CaA solution was above 4.5, but slight discoloration of apple slices dipped in pH 4.5 solution was observed after 14 days at 10 degrees C. At pH 5.0, the CaA dip maintained the quality of the apples at both temperatures for at least 21 days. The L. innocua population was reduced by 4 to 5 log CFU/ml at pH 4.5 after 96 h. At pH 5, the bacterial population in the CaA solution was reduced by approximately 2 log CFU/ml during the same period. The CaA solution was stable at pH 5 for at least 96 h. Reduction of the pH to between 4.5 and 5.0 might reduce the risk of foodborne illness due to consumption of fresh-cut apples treated with a CaA solution contaminated with Listeria.
Nita, Loredana Elena; Chiriac, Aurica P; Neamtu, Iordana; Bercea, Maria
2010-03-01
The interpenetrated macromolecular chains complexation between poly(aspartic acid) and poly(vinyl alcohol) in aqueous solution it was investigated. The interpolymer complexation process was evaluated through dynamic rheology. The aspects concerning the stability of the tested homopolymers and the prepared interpolymeric complex there were achieved from the evaluation of the aqueous solutions'zeta potential and also by determining the pH influence upon the zeta potential and the conductivity. The data obtained through the rheological dynamic measurements were correlated with the composition of the polymeric mixture, the dependence of zeta potential and conductivity. The study reveals the conditions for the formation of interpenetrated polymeric complex as being a ratio of 70wt.% PAS to 30wt.% PVA at 22 degrees C and 50/50 PAS/PVA ratio at 37 degrees C temperature. From the pH influence upon the zeta potential values it was evidenced the PAS aqueous solution does not reach the isoelectric point. At the same time, PVA solution and the complex PAS/PVA reaches the isoelectric point at strongly acid pH. The better stability of PAS, PVA and their mixture in solution is recorded in the alkaline domain (7.5
Removal of Cd (II) from water using the waste of jatropha fruit ( Jatropha curcas L.)
NASA Astrophysics Data System (ADS)
Nacke, Herbert; Gonçalves, Affonso Celso; Coelho, Gustavo Ferreira; Schwantes, Daniel; Campagnolo, Marcelo Angelo; Leismann, Eduardo Ariel Völz; Junior, Élio Conradi; Miola, Alisson Junior
2017-10-01
The aim of this work was to evaluate the removal of Cd (II) from water using three biosorbents originated from the biomass of jatropha (bark, endosperm, and endosperm + tegument). For that, batch tests were performed to verify the effect of solution pH, adsorbent mass, contact time, initial concentration of Cd (II), and the temperature of the process. The adsorption process was evaluated by the studies of kinetics, isotherms, and thermodynamics. The ideal conditions of solution pH were 5.5 and 8 g L-1 of adsorbent mass of biosorbents by solution volume, with an equilibrium time of 60 min. According to the Langmuir model, the maximum adsorption capacity for bark, endosperm, and bark + endosperm of jatropha was, respectively, 29.665, 19.562, and 34.674 mg g-1, predominating chemisorption in monolayers. The biosorbents presented potential for the remediation of waters contaminated with Cd (II).
Guerrero-Coronilla, Imelda; Morales-Barrera, Liliana; Cristiani-Urbina, Eliseo
2015-04-01
The present study explored the kinetics, equilibrium and thermodynamics of amaranth (acid red 27) anionic dye (AD) biosorption to water hyacinth leaves (LEC). The effect of LEC particle size, contact time, solution pH, initial AD concentration and temperature on AD biosorption was studied in batch experiments. AD biosorption increased with rising contact time and initial AD concentration, and with decreasing LEC particle size and solution pH. Pseudo-second-order chemical reaction kinetics provided the best correlation for the experimental data. Isotherm studies showed that the biosorption of AD onto LEC closely follows the Langmuir isotherm, with a maximum biosorption capacity of about 70 mg g(-1). The thermodynamic parameters confirm that AD biosorption by LEC is non-spontaneous and endothermic in nature. Results indicate that LEC is a strong biosorbent capable of effective detoxification of AD-laden wastewaters. Copyright © 2015 Elsevier Ltd. All rights reserved.
Thompson, Ronald W; Latypov, Ramil F; Wang, Ying; Lomakin, Aleksey; Meyer, Julie A; Vunnum, Suresh; Benedek, George B
2016-11-14
Colloidal stability of IgG antibody solutions is important for pharmaceutical and medicinal applications. Solution pH and ionic strength are two key factors that affect the colloidal stability of protein solutions. In this work, we use a method based on the PEG-induced liquid-liquid phase separation to examine the effects of pH and ionic strength on the colloidal stability of IgG solutions. We found that at high ionic strength (≥0.25M), the colloidal stability of most of our IgGs is insensitive to pH, and at low ionic strength (≤0.15M), all IgG solutions are much more stable at pH 5 than at pH 7. In addition, the PEG-induced depletion force is less efficient in causing phase separation at pH 5 than at pH 7. In contrast to the native inter-protein interaction of IgGs, the effect of depletion force on phase separation of the antibody solutions is insensitive to ionic strength. Our results suggest that the long-range electrostatic inter-protein repulsion at low ionic strength stabilizes the IgG solutions at low pH. At high ionic strength, the short-range electrostatic interactions do not make a significant contribution to the colloidal stability for most IgGs with a few exceptions. The weaker effect of depletion force at lower pH indicates a reduction of protein concentration in the condensed phase. This work advances our basic understanding of the colloidal stability of IgG solutions and also introduces a practical approach to measuring protein colloidal stability under various solution conditions.
Influence of annealing time on pH sensitivity of ZnO sensing membrane for EGFET sensor
NASA Astrophysics Data System (ADS)
Zulkefle, M. A.; Rahman, R. A.; Yusoff, K. A.; Abdullah, W. F. H.; Rusop, M.; Herman, S. H.
2018-05-01
Solid-state materials have becomes essential in recent technological advancements. This study also utilized solid-state material but in form of thin films to sense hydrogen ions in solutions. Fabrication of ZnO thin film was done using sol-gel spin coating technique. In an attempt to increase the pH sensitivity of the produced film, prolonging of annealing time was done. It was found that the increase in annealing time from 15 minutes to 30 minutes had managed to improve the sensitivity by 4.35%. The optimum pH sensitivity and linearity obtained in this study is 50.40 mV/pH and 0.9911 respectively.
Automated pH Control of Nutrient Solution in a Hydroponic Plant Growth System
NASA Technical Reports Server (NTRS)
Smith, B.; Dogan, N.; Aglan, H.; Mortley, D.; Loretan, P.
1998-01-01
Over, the years, NASA has played an important role in providing to and the development of automated nutrient delivery and monitoring, systems for growing crops hydroponically for long term space missions. One example are the systems used in the Biomass Production Chamber (BPC) at Kennedy Space Center (KSC). The current KSC monitoring system is based on an engineering workstation using standard analog/digital input/output hardware and custom written software. The monitoring system uses completely separate sensors to provide a check of control sensor accuracy and has the ability to graphically display and store data form past experiment so that they are available for data analysis [Fortson, 1992]. In many cases, growing systems have not been fitted with the kind of automated control systems as used at KSC. The Center for Food and Environmental Systems for Human Exploration of Space (CFESH) located on the campus of Tuskegee University, has effectively grown sweetpotatoes and peanuts hydroponically for the past five years. However they have adjusted the pH electrical conductivity and volume of the hydroponic nutrient solution only manually at times when the solution was to be replenished or changed out according to its protocol (e.g. one-week, two-week, or two-day cycle). But the pH of the nutrient solution flowing through the channel is neither known nor controlled between the update, change out, or replenishment period. Thus, the pH of the nutrient solution is not held at an optimum level over the span of the plant's growth cycle. To solve this dilemma, an automated system for the control and data logging of pH data relative to sweetpotato production using the nutrient film technique (NFT) has been developed, This paper discusses a microprocessor-based system, which was designed to monitor, control, and record the pH of a nutrient solution used for growing sweetpotatoes using NFT.
Equilibrium and kinetic modelling of chromium(III) sorption by animal bones.
Chojnacka, Katarzyna
2005-04-01
The paper discusses sorption of Cr(III) ions from aqueous solutions by animal bones. Animal bones were found to be an efficient sorbent with the maximum experimentally determined sorption capacity in the range 29-194 mg g(-1) that depended on pH and temperature. The maximum experimentally determined sorption capacity was obtained at 50 degrees C, pH 5. Batch kinetics and equilibrium experiments were performed in order to investigate the influence of contact time, initial concentration of sorbate and sorbent, temperature and pH. It was found that sorption capacity increased with increase of Cr(III) concentration, temperature and initial pH of metal solution. Mathematical models describing kinetics and statics of sorption were proposed. It was found that process kinetics followed the pseudo-second-order pattern. The influence of sorbent concentration was described with Langmuir-type equation and the influence of sorbate concentration was described with empirical dependence. The models were positively verified.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sundaramurthi, Prakash; Suryanarayanan, Raj
To effectively inhibit succinate buffer crystallization and the consequent pH changes in frozen solutions. Using differential scanning calorimetry (DSC) and X-ray diffractometry (XRD), the crystallization behavior of succinate buffer in the presence of either (i) a crystallizing (glycine, mannitol, trehalose) or (ii) a non-crystallizing cosolute (sucrose) was evaluated. Aqueous succinate buffer solutions, 50 or 200 mM, at pH values 4.0 or 6.0 were cooled from room temperature to -25 C at 0.5 C/min. The pH of the solution was measured as a function of temperature using a probe designed to function at low temperatures. The final lyophiles prepared from thesemore » solutions were characterized using synchrotron radiation. When the succinic acid solution buffered to pH 4.0, in the absence of a cosolute, was cooled, there was a pronounced shift in the freeze-concentrate pH. Glycine and mannitol, which have a tendency to crystallize in frozen solutions, remained amorphous when the initial pH was 6.0. Under this condition, they also inhibited buffer crystallization and prevented pH change. At pH 4.0 (50 mM initial concentration), glycine and mannitol crystallized and did not prevent pH change in frozen solutions. While sucrose, a non-crystallizing cosolute, did not completely prevent buffer crystallization, the extent of crystallization was reduced. Sucrose decomposition, based on XRD peaks attributable to {beta}-D-glucose, was observed in frozen buffer solutions with an initial pH of 4.0. Trehalose completely inhibited crystallization of the buffer components when the initial pH was 6.0 but not at pH 4.0. At the lower pH, the crystallization of both trehalose dihydrate and buffer components was evident. When retained amorphous, sucrose and trehalose effectively inhibited succinate buffer component crystallization and the consequent pH shift. However, when trehalose crystallized or sucrose degraded to yield a crystalline decomposition product, crystallization of buffer was observed. Similarly, glycine and mannitol, two widely used bulking agents, inhibited buffer component crystallization only when retained amorphous. In addition to stabilizing the active pharmaceutical ingredient, lyoprotectants may prevent solution pH shift by inhibiting buffer crystallization.« less
Mohamad, Nurhidayatul Asma; Mustafa, Shuhaimi; El Sheikha, Aly Farag; Khairil Mokhtar, Nur Fadhilah; Ismail, Amin; Ali, Md Eaqub
2016-05-01
Poor quality and quantity of DNA extracted from gelatin and gelatin capsules often causes failure in the determination of animal species using PCR. Gelatin, which is mainly derived from porcine and bovine, has been a matter of concern among customers in order to fulfill religious obligation and safety precaution against several transmissible infectious diseases associated with bovine species. Thus, optimised DNA extraction from gelatin is very important for successful real-time PCR detection of gelatin species. In this work, the DNA extraction method was optimised in terms of lysis incubation period and inclusion of pre-treatment pH modification of samples. The yield of DNA extracted from porcine gelatin was significantly increased when the pH of the samples was adjusted to pH 8.5 prior to DNA precipitation with isopropanol. The optimal pH for DNA precipitation from bovine gelatin solution was then determined at the original pH range of solution: pH 7.6 to 8. A DNA fragment of approximately 300 base pairs was available for PCR amplification. DNA extracted from gelatin and commercially available capsules has been successfully utilised for species detection using real-time PCR assay. However, significant adulterations of porcine and bovine in pure gelatin and capsules have been detected, which require further analytical techniques for validation. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Flory, Jason; Kanel, Sushil R.; Racz, LeeAnn; Impellitteri, Christopher A.; Silva, Rendahandi G.; Goltz, Mark N.
2013-03-01
Given the ubiquity of silver nanoparticles (AgNPs) and their potential for toxic effects on both humans and the environment, it is important to understand their environmental fate and transport. The purpose of this study is to gain information on the transport properties of commercial AgNP suspensions in a glass bead-packed column under saturated flow conditions at different solution pH levels. Commercial AgNPs were characterized using high-resolution transmission electron microscopy, dynamic light scattering, X-ray photoelectron spectroscopy, ultraviolet visible spectroscopy, Fourier transform infrared spectroscopy, thermogravimetric analysis, and X-ray diffraction. Transport data were collected at different pH levels (4, 6.5, 9, and 11) at fixed ionic strength. Capture of AgNPs increased as the pH of the solution increased from 4 to 6.5. Further increase in pH to 9 and 11 decreased the attachment of AgNPs to the glass beads. AgNP concentration versus time breakthrough data were simulated using an advection-dispersion model incorporating both irreversible and reversible attachment. In particular, a reversible attachment model is required to simulate breakthrough curve tailing at near neutral pH, when attachment is most significant. The laboratory and modeling study reveals that for natural groundwaters, AgNP transport in porous media may be retarded due to capture; but ultimately, most of the mass may be slowly released over time.
Human sweet taste receptor mediates acid-induced sweetness of miraculin
Koizumi, Ayako; Tsuchiya, Asami; Nakajima, Ken-ichiro; Ito, Keisuke; Terada, Tohru; Shimizu-Ibuka, Akiko; Briand, Loïc; Asakura, Tomiko; Misaka, Takumi; Abe, Keiko
2011-01-01
Miraculin (MCL) is a homodimeric protein isolated from the red berries of Richadella dulcifica. MCL, although flat in taste at neutral pH, has taste-modifying activity to convert sour stimuli to sweetness. Once MCL is held on the tongue, strong sweetness is sensed over 1 h each time we taste a sour solution. Nevertheless, no molecular mechanism underlying the taste-modifying activity has been clarified. In this study, we succeeded in quantitatively evaluating the acid-induced sweetness of MCL using a cell-based assay system and found that MCL activated hT1R2-hT1R3 pH-dependently as the pH decreased from 6.5 to 4.8, and that the receptor activation occurred every time an acid solution was applied. Although MCL per se is sensory-inactive at pH 6.7 or higher, it suppressed the response of hT1R2-hT1R3 to other sweeteners at neutral pH and enhanced the response at weakly acidic pH. Using human/mouse chimeric receptors and molecular modeling, we revealed that the amino-terminal domain of hT1R2 is required for the response to MCL. Our data suggest that MCL binds hT1R2-hT1R3 as an antagonist at neutral pH and functionally changes into an agonist at acidic pH, and we conclude this may cause its taste-modifying activity. PMID:21949380
Yamada, Akira; Mohri, Satoshi; Nakamura, Michihiro; Naruse, Keiji
2015-01-01
The liquid junction potential (LJP), the phenomenon that occurs when two electrolyte solutions of different composition come into contact, prevents accurate measurements in potentiometry. The effect of the LJP is usually remarkable in measurements of diluted solutions with low buffering capacities or low ion concentrations. Our group has constructed a simple method to eliminate the LJP by exerting spatiotemporal control of a liquid junction (LJ) formed between two solutions, a sample solution and a baseline solution (BLS), in a flow-through-type differential pH sensor probe. The method was contrived based on microfluidics. The sensor probe is a differential measurement system composed of two ion-sensitive field-effect transistors (ISFETs) and one Ag/AgCl electrode. With our new method, the border region of the sample solution and BLS is vibrated in order to mix solutions and suppress the overshoot after the sample solution is suctioned into the sensor probe. Compared to the conventional method without vibration, our method shortened the settling time from over two min to 15 s and reduced the measurement error by 86% to within 0.060 pH. This new method will be useful for improving the response characteristics and decreasing the measurement error of many apparatuses that use LJs. PMID:25835300
In situ chemical oxidation of BTEX and MTBE by ferrate: pH dependence and stability.
Pepino Minetti, Roberto C; Macaño, Héctor R; Britch, Javier; Allende, M Carla
2017-02-15
Gasoline spills from underground storage tanks are a worldwide environmental problem. BTEX and MtBE are the compounds of gasoline that present the highest degree of migration due to their chemical properties, and are therefore able to impact groundwater reservoirs. In situ chemical oxidation (ISCO) is an emerging technology for groundwater remediation. Several compounds such as permanganate and hydrogen peroxide among others have been used as oxidants, a strong impact of pH on the relative stabilities and reduction potentials having been in each case determined. This paper presents a study of stability and degradation of BTEX and MtBE at different pH ranges of a novel oxidant for ISCO, potassium ferrate (K 2 FeO 4 ). To carry out this study, BTEX and MtBE solutions were prepared in different phosphate buffers (pH 5,8; 7; 9; 10 and 11) in concentration ratio of (FeO 4 -2 )/(BTEX+MtBE)=100:1. Each solution was analyzed at different times by gas chromatography with photoionization and tandem mass spectrometer detector. The results show a higher degree of degradation at pH 7 for Benzene and Toluene, and at pH 9 for Ethyl benzene and Xylenes, while MtBE proved recalcitrant to degradation by ferrate. The most favorable pH for stability of FeO 4 -2 solution was confirmed in 9-10. Copyright © 2016 Elsevier B.V. All rights reserved.
Adsorption of allura red dye by cross-linked chitosan from shrimp waste.
Sánchez-Duarte, Reyna G; Sánchez-Machado, Dalia I; López-Cervantes, Jaime; Correa-Murrieta, Ma A
2012-01-01
The present study was designed to evaluate the chitosan, which has been obtained by deacetylation of chitin, as a biosorbent. The chitin was isolated from fermented shrimp waste by an important local industrial food biopolymer. The aim of this work was the characterization of chitosan and preparation of cross-linked chitosan- tripolyphosphate (chitosan-TPP) beads for the removal of allura red food dye from aqueous solutions. Conditions of batch adsorption such as pH, time and adsorbent dose were examined. The effectiveness of cross-linked chitosan beads for dye removal was found to be higher for pH 2 (98%, percentage of dye removal) and tends to decrease at pHs of 3 to 11 (up to 49%). The values of percentage removal show that the adsorption capacity increases with time of contact and dosage of chitosan-TPP, but red dye adsorption is mainly influenced by pH level. The cross-linked chitosan-TPP beads can significantly adsorb allura red monoazo dye from aqueous solutions even at acidic pHs unlike raw chitosan beads that tend to dissolve in acidic solutions. Consequently, this modified chitosan has characteristics that allow minimization of environmental pollution and widening the valorization of shrimp waste.
Removal of trivalent chromium from aqueous solution using aluminum oxide hydroxide.
Bedemo, Agaje; Chandravanshi, Bhagwan Singh; Zewge, Feleke
2016-01-01
Water is second most essential for human being. Contamination of water makes it unsuitable for human consumption. Chromium ion is released to water bodies from various industries having high toxicity which affects the biota life in these waters. In this study aluminum oxide hydroxide was tested for its efficiency to remove trivalent chromium from aqueous solutions through batch mode experiments. Chromium concentrations in aqueous solutions and tannery waste water before and after adsorption experiments were determined using flame atomic absorption spectrometry. The effects of pH, contact time, initial concentration and adsorbent dosage on the adsorption of Cr(III) were studied. The study revealed that more than 99 % removal of Cr(III) was achieved over wide range of initial pH (3-10). The optimum conditions for the removal of Cr(III) were found to be at pH 4-6 with 40 g/L adsorbent dose at 60 min of contact time. The adsorption capacity was assessed using Langmuir and Freundlich isotherms. The equilibrium data at varying adsorbent dose obeyed the two isotherms. The adsorbent was found to be efficient for the removal of Cr(III) from tannery waste effluent.
NASA Astrophysics Data System (ADS)
Salaheldin, Hosam I.
2018-06-01
In this study, silver nanoparticles (SNPs) were synthesised in an aqueous solution of corn starch. To fabricate the SNPs, reaction conditions, such as varying silver nitrate () concentration, time, temperature and solution pH of the reaction, were optimized. Since, the optimum reaction conditions were found 1 mmo l‑1, 15 min and , respectively. Then, to study the role of pH on SNP synthesis, varying pH values of the solution (3, 5, 7, 9 and 11) were investigated. Subsequently, the obtained silver/starch nanocomposites were characterised using different techniques. The x-ray diffraction (XRD) results revealed that the particles were face-centred cubic (FCC), and had an average particle size of 7.5 nm. This was confirmed by high-resolution transmission electron microscopy (HR-TEM) images. Moreover, the synthesised SNPs, at different pH values, were used as nanocatalyst for the reduction of 4-nitrophenol to 4-aminophenol in the presence of sodium borohydride. Under optimum reaction conditions, the higher catalytic activity was obtained with SNPs synthesised at pH 11 compared to lower pH of 7 or 9. Therefore, the rapid, reproducible, cost-effective silver/starch nanocomposite can be widely used for various applications such as drug manufacturing (e.g. analgesics and antipyretics) and the removal of pollutants from wastewater.
Effect of aniline on cadmium adsorption by sulfanilic acid-grafted magnetic graphene oxide sheets.
Hu, Xin-jiang; Liu, Yun-guo; Zeng, Guang-ming; Wang, Hui; Hu, Xi; Chen, An-wei; Wang, Ya-qin; Guo, Yi-Mming; Li, Ting-ting; Zhou, Lu; Liu, Shao-heng; Zeng, Xiao-xia
2014-07-15
Cd(II) has posed severe health risks worldwide. To remove this contaminant from aqueous solution, the sulfanilic acid-grafted magnetic graphene oxide sheets (MGOs/SA) were prepared and characterized. The mutual effects of Cd(II) and aniline adsorption on MGOs/SA were studied. The effects of operating parameters such as pH, ionic strength, contact time and temperature on the Cd(II) enrichment, as well as the adsorption kinetics and isotherm were also investigated. The results demonstrated that MGOs/SA could effectively remove Cd(II) and aniline from the aqueous solution and the two adsorption processes were strongly dependent on solution pH. The Cd(II) adsorption was reduced by the presence of aniline at pH<5.4 but was improved at pH>5.4. The presence of Cd(II) diminished the adsorption capacity for aniline at pH<7.8 but enhanced the aniline adsorption at pH>7.8. The decontamination of Cd(II) by MGOs/SA was influenced by ionic strength. Besides, the adsorption process could be well described by pseudo-second-order kinetic model. The intraparticle diffusion study revealed that the intraparticle diffusion was not the only rate-limiting step for the adsorption process. Moreover, the experimental data of isotherm followed the Freundlich isotherm model. Copyright © 2014 Elsevier Inc. All rights reserved.
Hexavalent chromium adsorption from aqueous solution using carbon nano-onions (CNOs).
Sakulthaew, Chainarong; Chokejaroenrat, Chanat; Poapolathep, Amnart; Satapanajaru, Tunlawit; Poapolathep, Saranya
2017-10-01
The capacity of carbon nano-onions (CNOs) to remove hexavalent chromium (Cr(VI)) from aqueous solution was investigated. Batch experiments were performed to quantify the effects of the dosage rate, pH, counter ions, and temperature. The adsorption of Cr(VI) onto CNOs was best described by a pseudo-second order rate expression. The adsorption efficiency increased with increasing adsorbent dosage and contact time and reached equilibrium in 24 h. The equilibrium data showed better compliance with a Langmuir isotherm than a Freundlich isotherm. Effective removal of Cr(VI) was demonstrated at pH values ranging from 2 to 10. The adsorption capacity of Cr(VI) was found to be highest (82%) at pH 3.4 and greatly depended on the solution pH. We found that Cr(VI) adsorption decreased with increasing pH over the pH range of 3.4-10. The adsorption capacity increased dramatically when the temperature increased from 10 °C to 50 °C regardless of the amount of CNOs used. Cr(VI) removal decreased by ∼13% when Zn(II), Cu(II), and Pb(II) were present, while there were no significant changes observed when NO 3 - or SO 4 2- was present. The overall results support that CNOs can be used as an alternative adsorbent material to remove Cr(VI) in the water treatment industry. Copyright © 2017 Elsevier Ltd. All rights reserved.
Futagawa, Masato; Iwasaki, Taichi; Murata, Hiroaki; Ishida, Makoto; Sawada, Kazuaki
2012-01-01
Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si(3)N(4) membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk.
Futagawa, Masato; Iwasaki, Taichi; Murata, Hiroaki; Ishida, Makoto; Sawada, Kazuaki
2012-01-01
Making several simultaneous measurements with different kinds of sensors at the same location in a solution is difficult because of crosstalk between the sensors. In addition, because the conditions at different locations in plant beds differ, in situ measurements in agriculture need to be done in small localized areas. We have fabricated a multimodal sensor on a small Si chip in which a pH sensor was integrated with electrical conductivity (EC) and temperature sensors. An ISFET with a Si3N4 membrane was used for the pH sensor. For the EC sensor, the electrical conductivity between platinum electrodes was measured, and the temperature sensor was a p-n junction diode. These are some of the most important measurements required for controlling the conditions in plant beds. The multimodal sensor can be inserted into a plant bed for in situ monitoring. To confirm the absence of crosstalk between the sensors, we made simultaneous measurements of pH, EC, and temperature of a pH buffer solution in a plant bed. When the solution was diluted with hot or cold water, the real time measurements showed changes to the EC and temperature, but no change in pH. We also demonstrated that our sensor was capable of simultaneous in situ measurements in rock wool without being affected by crosstalk. PMID:22969403
Galfi, Istvan; Virtanen, Jorma; Gasik, Michael M.
2017-01-01
A new, faster and more reliable analytical methodology for S(IV) species analysis at low pH solutions by bichromatometry is proposed. For decades the state of the art methodology has been iodometry that is still well justified method for neutral solutions, thus at low pH media possess various side reactions increasing inaccuracy. In contrast, the new methodology has no side reactions at low pH media, requires only one titration step and provides a clear color change if S(IV) species are present in the solution. The method is validated using model solutions with known concentrations and applied to analyses of gaseous SO2 from purged solution in low pH media samples. The results indicate that bichromatometry can accurately analyze SO2 from liquid samples having pH even below 0 relevant to metallurgical industrial processes. PMID:29145479
Kohno, Emiko; Nishikata, Mayumi; Okamura, Noboru; Matsuyama, Kenji
2008-01-01
Prostaglandin E(1) (PGE(1); Alprostadil Alfadex) is a potent vasodilator and inhibitor of platelet aggregation used to treat patients with peripheral vascular disease. The main adverse effects of intravenous PGE(1) administration, phlebitis and venous pain, arise from the unphysiologically low pH of infusion solutions. When PGE(1) infusion solutions with a pH value greater then 6 are used, phlebitis and venous pain are considered to be avoidable. Beginning with a PGE(1) infusion solution with pH greater than 6, we add the amount of 7% sodium bicarbonate needed to bring the solution to pH 7.4 if phlebitis or venous pain develops. In the present study we established a convenient nomogram showing the relationship between the titratable acidity of various infusion solutions and the volume of 7% sodium bicarbonate required to attain pH 7.4 for preventing the phlebitis and venous pain associated with PGE(1) infusion.
Uranium removal from aqueous solution by coir pith: equilibrium and kinetic studies.
Parab, Harshala; Joshi, Shreeram; Shenoy, Niyoti; Verma, Rakesh; Lali, Arvind; Sudersanan, M
2005-07-01
Basic aspects of uranium adsorption by coir pith have been investigated by batch equilibration. The influence of different experimental parameters such as final solution pH, adsorbent dosage, sorption time, temperature and various concentrations of uranium on uptake were evaluated. Maximum uranium adsorption was observed in the pH range 4.0-6.0. The Freundlich and Langmuir adsorption models were used for the mathematical description of the adsorption equilibrium. The equilibrium data fitted well to both the equilibrium models in the studied concentration range of uranium (200-800 mg/l) and temperatures (305-336 K). The coir pith exhibited the highest uptake capacity for uranium at 317 K, at the final solution pH value of 4.3 and at the initial uranium concentration of 800 mg/l. The kinetics of the adsorption process followed a second-order adsorption. The adsorbent used proved to be suitable for removal of uranium from aqueous solutions. 0.2 N HCl was effective in uranium desorption. The results indicated that the naturally abundant coir pith of otherwise nuisance value exhibited considerable potential for application in removal of uranium from aqueous solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haas, J.R.; Bailey, E.H.; Purvis, O.W.
1998-11-01
Uranium sorption experiments were carried out at {approximately}25 C using natural samples of the lichen Peltigera membranacea. Thalli were incubated in solutions containing 100 ppm U for up to 24 h at pH values from 2 to 10. Equilibrium sorption was not observed at less than {approximately}6 h under any pH condition. U sorption was strongest in the pH range 4--5, with maximum sorption occurring at a pH of 4.5 and an incubation time of 24 h. Maximum U uptake by P. membranacea averaged {approximately}42,000 ppm, or {approximately}4.2 wt% U. This appears to represent the highest concentration of biosorbed U,more » relative to solution U activity, of any lichen reported to date. Investigation of post-experimental lichen tissues using electron probe microanalysis (EPM) reveals that U uptake is spatially heterogeneous within the lichen body, and that U attains very high local concentrations on scattered areas of the upper cortex. Energy dispersive spectroscopic (EDS) analysis reveals that strong U uptake correlates with P signal intensity, suggesting involvement of biomass-derived phosphate ligands or surface functional groups in the uptake process.« less
Barman, Bhajendra N
2014-01-31
Carbonyl compounds, specifically aldehydes, present in amine catalysts or amines are determined by reversed-phase liquid chromatography using ultraviolet detection of their corresponding 2,4-dinitrophenylhydrazones. The primary focus has been to establish optimum conditions for determining aldehydes accurately because these add exposure concerns when the amine catalysts are used to manufacture polyurethane products. Concentrations of aldehydes determined by this method are found to vary with the pH of the aqueous amine solution and the derivatization time, the latter being problematic when the derivatization reaction proceeds slowly and not to completion in neutral and basic media. Accurate determination of aldehydes in amines through derivatization can be carried out at an effective solution pH of about 2 and with derivatization time of 20min. Hydrochloric acid has been used for neutralization of an amine. For complete derivatization, it is essential to protonate all nitrogen atoms in the amine. An approach for the determination of an adequate amount of acid needed for complete derivatization has been described. Several 0.2M buffer solutions varying in pH from 4 to 8 have also been used to make amine solutions for carrying out derivatization of aldehydes. These solutions have effective pHs of 10 or higher and provide much lower aldehyde concentrations compared to their true values. Mechanisms for the formation of 2,4-dinitrophenylhydrazones in both acidic and basic media are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.
Use of laterite for the removal of fluoride from contaminated drinking water.
Sarkar, Mitali; Banerjee, Aparna; Pramanick, Partha Pratim; Sarkar, Asit R
2006-10-15
The effects of different operational variables on the mechanistic function of laterite in removal of fluoride have been investigated. Thermodynamic parameters such as free energy change, enthalpy, and entropy of the process, as well as the sorption isotherm, were evaluated. The extent of solute removal is determined by initial solute concentration, operational conditions, laterite dose, and solution pH. For a fixed set of experimental conditions, a model equation is developed from which the percent removal corresponding to each load of fluoride is determined. The mechanism of fluoride adsorption is governed by the zero point charge of laterite and follows a first-order rate equation. pH has a vital role influencing the surface characteristics of laterite. To simulate the flow dynamics, fluoride solution was run through a fixed bed column. The pattern of breakthrough curves for different influent fluoride concentration, pH, and column bed height was characterized. The column efficiency was tested from the bed depth-service time model. The elution of the retained fluoride was studied and the effectiveness of column operation was determined by the retention-elution cycles.
Time to career: Science and engineering education to career trajectories
NASA Astrophysics Data System (ADS)
Choi, Angie Nim
Two waves of data from the 2006 and 2008 Survey of Earned Doctorates and Survey of Doctorate Recipients were used in this study to investigate time to doctorate (TTD) and time to career (TTC) for science and engineering PhDs. Three-way factorial ANOVAs were conducted, and TTD results indicated main effects for gender, US citizenship, and Biglan classification, and interaction effects for gender and US citizenship. US citizen PhDs progressed to their career approximately one mean year faster than foreign PhDs. For TTC, PhDs who held postdocs progressed to their careers in 14 and 15 years for females and males respectively compared to 19 years for those without postdoctoral appointments. PhDs working in academe also had shorter TTC rates than those working in industry or government settings. TTC rates were lowest for PhDs from engineering fields and highest for those from health sciences. A multiple linear regression based upon the 2006 data was also used to determine the best predictors of TTC based upon individual, academic, and employer characteristics, and the model was cross-validated with an independent sample from the 2008 data. The regression solution was significant, F (20, 11000) = 97.06, p < .001, and significant predictors were gender, US citizen, children ages 2-5, married or married-like relationship, TTD, teaching assistantship, research assistantship, student loans, salary, postdoc, government employer, and business/industry employer. The regression solution for predicting TTC had a medium effect size (R2 = .14), and the cross-validated model had a slightly higher effect (R2 = .28).
[In vitro study of vitamins B1, B2 and B6 adsorption on zeolite].
Basić, Zorica; Kilibarda, Vesna; Dobrić, Silva; Resanović, Radmila
2011-01-01
Zeolites are the hydratised alumosilicates of alcali and earthalcali cations, which have a long three-dimensional crystal structure. Preparations on the basis of zeolites are used for adsorption of organic and nonorganic toxic substances and they, also, find more and more use in veterinary and human medicine and pharmacy. The aim of this study was to evaluate the possibilities of zeolite to adsorb vitamins B1, B2 and B6 in acid and neutral solutions, as well as the characteristics of the process (saturability, reversibility and competitiveness). The specific and sensitive HPLC method with fluorescent detector was used for determination of vitamins B1, B2 and B6. Analyte separation and detection were carried out by applying the reverse-phase method on column C18. An in vitro experiment was done by testing the influence of pH value (2 and 7), concentration of vitamin solution (1, 2 and 5 mg/L), the length of contact with zeolite (10-180 min) and cation competitiveness on the exchange capacity, which is achieved by media and zeolite contact, as well as a possible vitamins desorption through changing pH value of the solution at 37 degrees C. Jon competitiveness was examined by adding commercial feed mixture (grower) with a defined content of the examined vitamins in zeolite solutions the pH = 2 and pH = 7. Vitamins B1, B2 and B6 were stable in both pH=2 and pH = 7 solutions at 37 degrees C, in the defined time intervals. In acid solution concentrations of vitamins significantly declined in the first 10 min, with no significant decline in further 30 min for all the three concentrations tests. In neutral solution, after the addition of 1% zeolite, decrease in vitamins concentrations was slightly lower than in acid solution, but also significant in the first 10 min of the contact with zeolite. It was found that zeolite, which adsorbed vitamins in acid solution, transferred in the neutral one released a significant quantity of adsorbed vitamins after 30 min of extraction on 37 degrees C. Vitamins B1, B2 and B6, from a commercial feed mixture in pH = 2 solution, at 37 degrees C, were significantly adsorbed on zeolite after 30 min of the contact (21.87%, 20.15% and 4.53%, respectively), while in neutral solution there was no statistically significant adsorption. Conclusion. Zeolite significantly adsorbs vitamins B1, B2 and B6 in acid and neutral solutions at 37 degrees C, already in the first 10 min of the contact. Adsorption was irreversible, but partly reversible after changing pH from acid to neutral. This is a significant ions competition for adsorption on zeolite in neutral solution, so no statistically significant vitamins B1, B2 and B6 adsorption occurs, while in acid solution competition is less, thus zeolite significantly adsorbs these vitamins, although in less degree than in conditions with no concurrent ions.
Kaneko, Kenitiro; Ono, Yasuyuki; Tainaka, Takahisa; Sumida, Wataru; Ando, Hisami
2009-07-01
Symptoms of choledochal cysts are caused by protein plugs made of lithostathine, which block the long common channel and increase pancreaticobiliary ductal pressure. Agents that dissolve protein plugs can provide relief from or prevent symptoms. In the present study, drugs reportedly effective for pancreatic and biliary stones were used in dissolution tests. Protein plugs were obtained from choledochal cysts during surgery in two children (5- and 6-year-old girls). Plugs approximately 2 mm in diameter were immersed in citric acid, tartaric acid, dimethadione, bromhexine, dehydrocholic acid, sodium citrate, hydrochloric acid, and sodium hydroxide solutions under observation with a digital microscope. The pH of each solution was measured using a pH meter. Plugs dissolved in citric acid (5.2 mM; pH 2.64), tartaric acid (6.7 mM; pH 2.51), dimethadione (75 mM; pH 3.70), hydrochloric acid (0.5 mM; pH 3.13), and sodium hydroxide (75 mM; pH 12.75) solutions. Plugs did not dissolve in dimethadione (7.5 mM; pH 4.31), bromhexine (0.1%; pH 4.68), dehydrocholic acid (5%; pH 7.45), and sodium citrate (75 mM; pH 7.23) solutions. Protein plugs in choledochal cysts are dissolved in acidic and basic solutions, which may eliminate longitudinal electrostatic interactions of the lithostathine protofibrils.
Computer model of hydroponics nutrient solution pH control using ammonium.
Pitts, M; Stutte, G
1999-01-01
A computer simulation of a hydroponics-based plant growth chamber using ammonium to control pH was constructed to determine the feasibility of such a system. In nitrate-based recirculating hydroponics systems, the pH will increase as plants release hydroxide ions into the nutrient solution to maintain plant charge balance. Ammonium is an attractive alternative to traditional pH controls in an ALSS, but requires careful monitoring and control to avoid overdosing the plants with ammonium. The primary advantage of using NH4+ for pH control is that it exploits the existing plant nutrient uptake charge balance mechanisms to maintain solution pH. The simulation models growth, nitrogen uptake, and pH of a l-m2 stand of wheat. Simulation results indicated that ammonium-based control of nutrient solution pH is feasible using a proportional integral controller. Use of a 1 mmol/L buffer (Ka = 1.6 x 10(-6)) in the nutrient solution is required.
Improved reliability of pH measurements.
Spitzer, Petra; Werner, Barbara
2002-11-01
Measurements of pH are performed on a large scale at laboratory level, and in industry. To meet the quality-control requirements and other technical specifications there is a need for traceability in measurement results. The prerequisite for the international acceptance of analytical data is reliability. To measure means to compare. Comparability entails use of recognised references to which the standard buffer solutions used for calibration of pH meter-electrode assemblies can be traced. The new recommendation on the measurement of pH recently published as a provisional document by the International Union on Pure and Applied Chemistry (IUPAC) enables traceability for measured pH values to a conventional reference frame which is recognised world-wide. The primary method for pH will be described. If analytical data are to be accepted internationally it is necessary to demonstrate the equivalence of the national traceability structures, including national measurement standards. For the first time key comparisons for pH have been performed by the Consultative Committee for Amount of Substance (CCQM, set up by the International Bureau of Weights and Measures, BIPM) to assess the equivalence of the national measurement procedures used to determine the pH of primary standard buffer solutions. The results of the first key comparison on pH CCQM-K9, and other international initiatives to improve the consistency of the results of measurement for pH, are reported.
Munshi, Tasnim; Brewster, Victoria L; Edwards, Howell G M; Hargreaves, Michael D; Jilani, Shelina K; Scowen, Ian J
2013-08-01
Gamma-hydroxybutyric acid (GHB) is a drug-of-abuse that has recently become associated with drug-facilitated sexual assault, known as date rape. For this reason the drug is commonly found 'spiked' in alcoholic beverages. When GHB is in solution it may undergo conversion into the corresponding lactone, Gamma-butyrolactone (GBL). Studies have been carried out to determine the detection limits of GHB and GBL in various solutions by Raman spectroscopy and to monitor the interconversion of GHB and GBL in solution with different pH conditions and temperature. In this study, a portable Raman spectrometer was used to study the interconversion of GHB and GBL in water and ethanol solutions as a function of pH, time, and temperature. The aim of this was to determine the optimum pH range for conversion in order to relate this to the pH ranges that the drug is likely to be subjected to, first in spiked beverages and secondly after ingestion in the digestive system. The aim was also to identify a timescale for this conversion in relation to possible scenarios, for example if GHB takes a number of hours to convert to GBL, it is likely for the beverage to be ingested before esterification can take place. GHB and GBL were then spiked into a selection of beverages of known pH in order to study the stability of GHB and GBL in real systems. Copyright © 2012 John Wiley & Sons, Ltd.
Morcillo, Fernando; González-Muñoz, María T.; Reitz, Thomas; Romero-González, María E.; Arias, José M.; Merroun, Mohamed L.
2014-01-01
The main goal of this study is to compare the effects of pH, uranium concentration, and background electrolyte (seawater and NaClO4 solution) on the speciation of uranium(VI) associated with the marine bacterium Idiomarina loihiensis MAH1. This was done at the molecular level using a multidisciplinary approach combining X-ray Absorption Spectroscopy (XAS), Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS), and High Resolution Transmission Electron Microscopy (HRTEM). We showed that the U(VI)/bacterium interaction mechanism is highly dependent upon pH but also the nature of the used background electrolyte played a role. At neutral conditions and a U concentration ranging from 5·10−4 to 10−5 M (environmentally relevant concentrations), XAS analysis revealed that uranyl phosphate mineral phases, structurally resembling meta-autunite [Ca(UO2)2(PO4)2 2–6H2O] are precipitated at the cell surfaces of the strain MAH1. The formation of this mineral phase is independent of the background solution but U(VI) luminescence lifetime analyses demonstrated that the U(VI) speciation in seawater samples is more intricate, i.e., different complexes were formed under natural conditions. At acidic conditions, pH 2, 3 and 4.3 ([U] = 5·10−4 M, background electrolyte = 0.1 M NaClO4), the removal of U from solution was due to biosorption to Extracellular Polysaccharides (EPS) and cell wall components as evident from TEM analysis. The L III-edge XAS and TRLFS studies showed that the biosorption process observed is dependent of pH. The bacterial cell forms a complex with U through organic phosphate groups at pH 2 and via phosphate and carboxyl groups at pH 3 and 4.3, respectively. The differences in the complexes formed between uranium and bacteria on seawater compared to NaClO4 solution demonstrates that the actinide/microbe interactions are influenced by the three studied factors, i.e., the pH, the uranium concentration and the chemical composition of the solution. PMID:24618567
Adsorption of Ni(II) onto Chemically Modified Spent Grated Coconut (Cocos Nucifera)
NASA Astrophysics Data System (ADS)
Hamzah, F. I.; Khalid, K.; Hanafiah, M. A. K. M.
2017-06-01
A new adsorbent of plant waste origin from coconut processing food factory was explored for removing Ni(II) from aqueous solutions. Several parameters such as pH, dosage, concentration and contact time were studied to obtain optimum conditions for treatment of Ni(II) contaminated wastewater. Spent grated coconut (Cocos nucifera) treated with sulfuric acid (SSGC) showed good adsorption capacity for Ni(II) ion. The amount adsorbed was affected by solution pH with the highest value achieved at pH 5. Other optimum conditions found were; dosage of 0.02 g, and 60 min of equilibrium time. Ni(II) adsorption obeyed the pseudo-second order kinetic model which suggested that chemisorption mechanism occurred in the adsorption process. The equilibrium data presented a better fitting to the Langmuir isotherm model, an indication that monolayer adsorption occurred onto a homogeneous surface. The maximum adsorption capacity, qmax was 97.09 mg g-1, thus SSGC can be classified as good and comparable with other plant waste adsorbents.
Barnett, Jason; Watson, Jean -Paul; Woodruff, David L.
2016-11-27
Progressive hedging, though an effective heuristic for solving stochastic mixed integer programs (SMIPs), is not guaranteed to converge in this case. Here, we describe BBPH, a branch and bound algorithm that uses PH at each node in the search tree such that, given sufficient time, it will always converge to a globally optimal solution. Additionally, to providing a theoretically convergent “wrapper” for PH applied to SMIPs, computational results demonstrate that for some difficult problem instances branch and bound can find improved solutions after exploring only a few nodes.
Properties of edible films based on pullulan-chitosan blended film-forming solutions at different pH
USDA-ARS?s Scientific Manuscript database
Influences of solution pH on the properties of pullulan-chitosan blended (Pul-Chi) films and the rheological properties of film-forming solutions were investigated. The extended conformation of chitosan in pH 4.0 solution increased intermolecular interactions with pullulan compared to the more compa...
Tetragonal Chicken Egg White Lysozyme Solubility in Sodium Chloride Solutions
NASA Technical Reports Server (NTRS)
Forsythe, Elizabeth L.; Judge, Russell A.; Pusey, Marc L.
1998-01-01
The solubility of chicken egg white lysozyme, crystallized in the tetragonal form was measured in sodium chloride solutions from 1.6 to 30.7 C, using a miniature column solubility apparatus. Sodium chloride solution concentrations ranged from 1 to 7% (w/v). The solutions were buffered with 0.1 M sodium acetate buffer with the solubility being measured at pH values in 0.2 pH unit increments in the range pH 4.0 to 5.4, with data also included at pH 4.5. Lysozyme solubility was found to increase with increases in temperature and decreasing salt concentration. Solution pH has a varied and unpredictable effect on solubility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Begg, James D.; Zavarin, Mavrik; Kersting, Annie B.
Desorption of plutonium (Pu) will likely control the extent to which it is transported by mineral colloids. In this article, we evaluated the adsorption/desorption behavior of Pu on SWy-1 montmorillonite colloids at pH 4, pH 6, and pH 8 using batch adsorption and flow cell desorption experiments. After 21 days adsorption, Pu(IV) affinity for montmorillonite displayed a pH dependency, with K d values highest at pH 4 and lowest at pH 8. The pH 8 experiment was further allowed to equilibrate for 6 months and showed an increase in K d, indicating that true sorption equilibrium was not achieved withinmore » the first 21 days. For the desorption experiments, aliquots of the sorption suspensions were placed in a flow cell, and Pu-free solutions were then pumped through the cell for a period of 12 days. Changes in influent solution flow rate were used to investigate the kinetics of Pu desorption and demonstrated that it was rate-limited over the experimental timescales. At the end of the 12-day flow cell experiments, the extent of desorption was again pH dependent, with pH 8 > pH 6 > pH 4. Further, at pH 8, less Pu was desorbed after an adsorption contact time of 6 months than after a contact time of 21 days, consistent with an aging of Pu on the clay surface. In addition, a conceptual model for Pu adsorption/desorption that incorporated known surface-mediated Pu redox reactions was used to fit the experimental data. The resulting rate constants indicated processes occurring on timescales of months and even years which may, in part, explain observations of clay colloid-facilitated Pu transport on decadal timescales. Importantly, however, our results also imply that migration of Pu adsorbed to montmorillonite colloids at long (50–100 year) timescales under oxic conditions may not be possible without considering additional phenomena, such as co-precipitation.« less
Desorption of plutonium from montmorillonite: An experimental and modeling study
Begg, James D.; Zavarin, Mavrik; Kersting, Annie B.
2017-01-15
Desorption of plutonium (Pu) will likely control the extent to which it is transported by mineral colloids. In this article, we evaluated the adsorption/desorption behavior of Pu on SWy-1 montmorillonite colloids at pH 4, pH 6, and pH 8 using batch adsorption and flow cell desorption experiments. After 21 days adsorption, Pu(IV) affinity for montmorillonite displayed a pH dependency, with K d values highest at pH 4 and lowest at pH 8. The pH 8 experiment was further allowed to equilibrate for 6 months and showed an increase in K d, indicating that true sorption equilibrium was not achieved withinmore » the first 21 days. For the desorption experiments, aliquots of the sorption suspensions were placed in a flow cell, and Pu-free solutions were then pumped through the cell for a period of 12 days. Changes in influent solution flow rate were used to investigate the kinetics of Pu desorption and demonstrated that it was rate-limited over the experimental timescales. At the end of the 12-day flow cell experiments, the extent of desorption was again pH dependent, with pH 8 > pH 6 > pH 4. Further, at pH 8, less Pu was desorbed after an adsorption contact time of 6 months than after a contact time of 21 days, consistent with an aging of Pu on the clay surface. In addition, a conceptual model for Pu adsorption/desorption that incorporated known surface-mediated Pu redox reactions was used to fit the experimental data. The resulting rate constants indicated processes occurring on timescales of months and even years which may, in part, explain observations of clay colloid-facilitated Pu transport on decadal timescales. Importantly, however, our results also imply that migration of Pu adsorbed to montmorillonite colloids at long (50–100 year) timescales under oxic conditions may not be possible without considering additional phenomena, such as co-precipitation.« less
Desorption of plutonium from montmorillonite: An experimental and modeling study
NASA Astrophysics Data System (ADS)
Begg, James D.; Zavarin, Mavrik; Kersting, Annie B.
2017-01-01
Desorption of plutonium (Pu) will likely control the extent to which it is transported by mineral colloids. We evaluated the adsorption/desorption behavior of Pu on SWy-1 montmorillonite colloids at pH 4, pH 6, and pH 8 using batch adsorption and flow cell desorption experiments. After 21 days adsorption, Pu(IV) affinity for montmorillonite displayed a pH dependency, with Kd values highest at pH 4 and lowest at pH 8. The pH 8 experiment was further allowed to equilibrate for 6 months and showed an increase in Kd, indicating that true sorption equilibrium was not achieved within the first 21 days. For the desorption experiments, aliquots of the sorption suspensions were placed in a flow cell, and Pu-free solutions were then pumped through the cell for a period of 12 days. Changes in influent solution flow rate were used to investigate the kinetics of Pu desorption and demonstrated that it was rate-limited over the experimental timescales. At the end of the 12-day flow cell experiments, the extent of desorption was again pH dependent, with pH 8 > pH 6 > pH 4. Further, at pH 8, less Pu was desorbed after an adsorption contact time of 6 months than after a contact time of 21 days, consistent with an aging of Pu on the clay surface. A conceptual model for Pu adsorption/desorption that incorporated known surface-mediated Pu redox reactions was used to fit the experimental data. The resulting rate constants indicated processes occurring on timescales of months and even years which may, in part, explain observations of clay colloid-facilitated Pu transport on decadal timescales. Importantly, however, our results also imply that migration of Pu adsorbed to montmorillonite colloids at long (50-100 year) timescales under oxic conditions may not be possible without considering additional phenomena, such as co-precipitation.
Uptakes of Cs and Sr on San Joaquin soil measured following ASTM method C1733.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, W.L.; Petri, E.T.
2012-04-04
Series of tests were conducted following ASTM Standard Procedure C1733 to evaluate the repeatability of the test and the effects of several test parameters, including the solution-to-soil mass ratio, test duration, pH, and the concentrations of contaminants in the solution. This standard procedure is recommended for measuring the distribution coefficient (K{sub d}) of a contaminant in a specific soil/groundwater system. One objective of the current tests was to identify experimental conditions that can be used in future interlaboratory studies to determine the reproducibility of the test method. This includes the recommendation of a standard soil, the range of contaminant concentrationsmore » and solution matrix, and various test parameters. Quantifying the uncertainty in the distribution coefficient that can be attributed to the test procedure itself allows the differences in measured values to be associated with differences in the natural systems being studied. Tests were conducted to measure the uptake of Cs and Sr dissolved as CsCl and Sr(NO{sub 3}){sub 2} in a dilute NaHCO{sub 3}/SiO{sub 2} solution (representing contaminants in a silicate groundwater) by a NIST standard reference material of San Joaquin soil (SRM 2709a). Tests were run to measure the repeatability of the method and the sensitivity of the test response to the reaction time, the mass of soil used (at a constant soil-to-solution ratio), the solution pH, and the contaminant concentration. All tests were conducted in screw-top Teflon vessels at 30 C in an oven. All solutions were passed through a 0.45-{mu}m pore size cellulose acetate membrane filter and stabilized with nitric acid prior to analysis with inductively-coupled plasma mass spectrometry (ICP-MS). Scoping tests with soil in demineralized water resulted in a solution pH of about 8.0 and the release of small amounts of Sr from the soil. Solutions were made with targeted concentrations of 1 x 10{sup -6} m, 1 x 10{sup -5} m, 2.5 x 10{sup -5} m, 5 x 10{sup -5} m, 1 x 10{sup -4} m, and 5 x 10{sup -4} m to measure the effects of the Cs and Sr concentrations on their uptake by the soil. The pH values of all solutions were adjusted to about pH 8.5 so that the effects of pH and concentration could be measured separately. The 1 x 10{sup -4} m solutions were used to measure the repeatability of the test and the effects of duration, scale, and imposed pH on the test response.« less
Biosorption of molybdenum and chromium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pryfogle, P.A.; Maiers, D.T.; Wichlacz, P.L.
1989-01-01
The effects of metal solution concentration, biomass density, length of exposure time, and pH were determined for biosorption of molybdenum (Mo) and chromium (Cr) by three organisms. Results indicate that it is possible to sorb Mo and Cr from dilute solutions. Differences were observed in the abilities of an organism to sorb Mo and Cr as well as among respective abilities of the three microorganisms. This suggests an inherent selectivity of the organism which may afford the selectivity of the organism which may afford the means to control a sorption-based process. Results also indicate that the metal sorption abilities ofmore » these microorganisms depend on duration of exposure, biomass density, solution pH, and the metal concentration of the solution. Each of these parameters suggests an additional means of controlling the sorption process. 20 refs., 6 figs., 3 tabs.« less
Hydroponic system design with real time OS based on ARM Cortex-M microcontroller
NASA Astrophysics Data System (ADS)
Atmadja, Wiedjaja; Liawatimena, Suryadiputra; Lukas, Jonathan; Nata, Eka Putra Leo; Alexander, Ivan
2017-12-01
Hydroponic is the process of growing plants without soil, plant root flooded or moist with nutrient-rich solutions in inert material. Hydroponics has become a reality for greenhouse growers in virtually all climates. Large hydroponic installations exist throughout the world for growing flowers, vegetables and some short period fruit like tomato and cucumber. In soilless culture, we must maintain stable pH and conductivity level of nutrient solution to make plant grow well, large variation of pH of certain time will poisoned plant. This paper describes development complete automation hydroponic system, from maintaining stable nutrient composition (conductivity and pH), grow light, and monitor plant environment such as CO2, temperature and humidity. The heart of our automation is ARM Cortex-M4 from ST Microelectronic running ARM mbed OS, the official Real Time Operating System (RTOS) for ARM Cortex-M microcontroller. Using RTOS gives us flexibility to have multithreaded process. Results show that system capable to control desired concentration level with variation of less than 3%, pH sensor show good accuracy 5.83% from pH value 3.23-10. Growing light intensity measurement show result 105 μmol/m2/s therefore we need turn on the light at least 17 hours/day to fulfil plant light requirement. RTOS give good performance with latency and jitter less than 15 us, system overall show good performance and accuracy for automating hydroponic plant in vegetative phase of growth.
The pH-dependent rate of action of local anesthetics on the node of Ranvier
1977-01-01
Local anesthetic solutions were applied suddenly to the outside of single myelinated nerve fibers to measure the time course of development of block of sodium channels. Sodium currents were measured under voltage clamp with test pulses applied several times per second during the solution change. The rate of block was studied by using drugs of different lipid solubility and of different charge type, and the external pH was varied from pH 8.3 to pH 6 to change the degree of ionization of the amine compounds. At pH 8.3 the half-time of action of amine anesthetics such as lidocaine, procaine, tetracaine, and others was always less than 2 s and usually less than 1 s. Lowering the pH to 6.0 decreased the apparent potency and slowed the rate of action of these drugs. The rate of action of neutral benzocaine was fast (1 s) and pH independent. The rate of action of cationic quaternary QX-572 was slow (greater than 200 s) and also pH independent. Other quaternary anesthetic derivatives showed no action when applied outside. The result is that neutral drug forms act much more rapidly than charged ones, suggesting that externally applied local anesthetics must cross a hydrophobic barrier to reach their receptor. A model representing diffusion of drug into the nerve fiber gives reasonable time courses of action and reasonable membrane permeability coefficients on the assumption that the hydrophobic barrier is the nodal membrane. Arguments are given that there may be a need for reinterpretation of many published experiments on the location of the anesthetic receptor and on which charge form of the drug is active to take into account the effects of unstirred layers, high membrane permeability, and high lipid solubility. PMID:16078
Hao, F; Lwin, T; Bruckard, W J; Woodcock, J T
2004-11-05
The method described here fulfils the need for a suitable analytical method to determine the concentrations of single and mixed aliphatic amines in the range from hexylamine (C6) to octadecylamine (C18) in flotation test solutions and in commercial flotation collectors. Amines do not have a UV-vis spectrum in aqueous solution but by reacting an amine-containing solution with 4-chloro-7-nitrobenzofurazan solution (chloro-NBD), derivatized products (amino-NBDs) are formed which have absorbance maxima at 470nm. Excess chloro-NBD and the amino-NBDs can be separated from each other by high-performance liquid chromatography (HPLC) and their concentrations measured with a UV-vis detector. Important variables in the derivatization stage are pH, temperature, chloro-NBD concentration, and reaction time, all of which interact with each other. A three-stage statistical procedure was used to determine the optimum conditions. In each stage, an 8-test design was used in which a high and low limit was set for each variable, and the chromatogram peak area of the derived amino-NBD was measured. The optimum derivatization conditions established were pH 8.9, chloro-NBD concentration 0.20% (w/v), temperature 70 degrees C, and reaction time 60 min. Optimum elution conditions for chromatography were an eluent containing 80% (v/v) acetonitrile in aqueous solution containing 40mM acetic acid at pH 4.5. With a flow rate of 2.0 ml/min, dodecylamine had a retention time of about 3 min, whereas octadecylamine had a retention time of 44 min. Straight-line calibration curves were obtained up to at least 200 ppm of amine in solution. The lower limit of detection was estimated to be 0.05 microM (10ppb) with a signal to noise ratio of 3. No interfering substances were found. The method was successfully applied to the analysis of solutions from an actual flotation test and to a solid commercial amine.
Particle characterization of poorly water-soluble drugs using a spray freeze drying technique.
Kondo, Masahiro; Niwa, Toshiyuki; Okamoto, Hirokazu; Danjo, Kazumi
2009-07-01
A spray freeze drying (SFD) method was developed to prepare the composite particles of poorly water-soluble drug. The aqueous solution dissolved drug and the functional polymer was sprayed directly into liquid nitrogen. Then, the iced droplets were lyophilized with freeze-dryer to prepare solid particles. Tolbutamide (TBM) and hydroxypropylmethylcellulose (HPMC) were used as a model drug and water-soluble polymeric carrier in this study, respectively. The morphological observation of particles revealed that the spherical particles having porous structure could be obtained by optimizing the loading amount of drug and polymer in the spray solution. Especially, SFD method was characterized that the prepared particles had significantly larger specific surface area comparing with those prepared by the standard spray drying technique. The physicochemical properties of the resultant particles were found to be dependent on the concentration of spray solution. When the solution with high content of drug and polymer was used, the particle size of the resulting composite particles increased and they became spherical. The specific surface area of the particles also increased as a result of higher concentration of solution. The evaluation of spray solution indicated that these results were dependent on the viscosity of spray solution. In addition, when composite particles of TBM were prepared using the SFD method with HPMC as a carrier, the crystallinity of TBM decreased as the proportion of HPMC increased. When the TBM : HPMC ratio reached 1 : 5, the crystallinity of the particles completely disappeared. The dissolution tests showed that the release profiles of poorly water-soluble TBM from SFD composite particles were drastically improved compared to bulk TBM. The 70% release time T(70) of composite particles prepared by the SFD method in a solution of pH 1.2 was quite smaller than that of bulk TBM, while in a solution of pH 6.8, it was slightly lower. In addition, the release rates were faster than those of standard spray dried (SD) composite particles for solutions of pH 1.2 and 6.8, respectively. When composite particles were prepared from mixtures with various composition ratios, T(70) was found to decrease as the proportion of HPMC increased; the release rate was faster than that of bulk TBM in a solution of pH 6.8, as well as solution of pH 1.2.
Stability of tacrolimus solutions in polyolefin containers.
Lee, Jun H; Goldspiel, Barry R; Ryu, Sujung; Potti, Gopal K
2016-02-01
Results of a study to determine the stability of tacrolimus solutions stored in polyolefin containers under various temperature conditions are reported. Triplicate solutions of tacrolimus (0.001, 0.01, and 0.1 mg/mL) in 0.9% sodium chloride injection or 5% dextrose injection were prepared in polyolefin containers. Some samples were stored at room temperature (20-25 °C); others were refrigerated (2-8 °C) for 20 hours and then stored at room temperature for up to 28 hours. The solutions were analyzed by stability-indicating high-performance liquid chromatography (HPLC) assay at specified time points over 48 hours. Solution pH was measured and containers were visually inspected at each time point. Stability was defined as retention of at least 90% of the initial tacrolimus concentration. All tested solutions retained over 90% of the initial tacrolimus concentration at all time points, with the exception of the 0.001-mg/mL solution prepared in 0.9% sodium chloride injection, which was deemed unstable beyond 24 hours. At all evaluated concentrations, mean solution pH values did not change significantly over 48 hours; no particle formation was detected. During storage in polyolefin bags at room temperature, a 0.001-mg/mL solution of tacrolimus was stable for 24 hours when prepared in 0.9% sodium chloride injection and for at least 48 hours when prepared in 5% dextrose injection. Solutions of 0.01 and 0.1 mg/mL prepared in either diluent were stable for at least 48 hours, and the 0.01-mg/mL tacrolimus solution was also found to be stable throughout a sequential temperature protocol. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Adsorption of Crystal Violet Dye Using Zeolite A Synthesized From Coal Fly Ash
NASA Astrophysics Data System (ADS)
Jumaeri; Kusumastuti, E.; Santosa, S. J.; Sutarno
2017-02-01
Adsorption of Crystal Violet (CV) dye using zeolite A synthesized from coal fly ash (ZA) has been done. Effect of pH, contact time, and the initial concentration of dye adsorption was studied in this adsorption. Model experimental of adsorption isotherms and adsorption kinetics were also studied. The adsorption is done in a batch reactor at room temperature. A total of 0.01 g of zeolite A was added to the Erlenmeyer flask 50 mL containing 20 mL of the dye solution of Crystal Violet in a variety of conditions of pH, contact time and initial concentration. Furthermore, Erlenmeyer flask and its contents were shaken using an orbital shaker at a speed of 200 rpm. After a specified period of adsorption, the solution was centrifuged for 2 minutes so that the solids separated from the solution. The concentration of the dye after adsorption determined using Genesis-20 Spectrophotometer. The results showed that the Zeolite A synthesized from coal fly ash could be used as an effective adsorbent for Crystal Violet dye. The optimum adsorption occurs at pH 6, and contact time 45 minutes. At the initial concentration of 2 to 6 mg/L, adsorption is reduced from 79 to 62.8%. Crystal Violet dye adsorption in zeolite A fulfilled kinetic model of pseudo-order 2 and model of Freundlich adsorption isotherm.
Fuel Cell System Contaminants Material Screening Data | Hydrogen and Fuel
contaminants; solution conductivity; pH; total organic carbon (TOC); cyclic voltammetry (CV); membrane conductivity) and organics (measured as total organic carbon) in leachate solutions. Each plot shows the ) contaminants on voltage loss over time for each materials class. GCMS Summary: Top 4 Organic Compounds by
Inorganic-polymer-derived dielectric films
Brinker, C.J.; Keefer, K.D.; Lenahan, P.M.
1985-02-25
A method is disclosed for coating a substrate with a thin film of a predetermined porosity. The method comprises: depositing the thin film on the substrate from a non-gelled solution comprising at least one metal alkoxide of a polymeric network forming cation, water, an alcohol compatible with the hydrolysis and the polymerization of the metal alkoxide, and an acid or a base; prior to said depositing step, controlling the porosity and structure of said coating for a given composition of said solution exclusive of the acid or base component and the water component, by adjusting each of the water content, the pH, the temperature and the time of standing of said solution, increasing/descreasing the water content or the pH to increase/decrease the pore size of said coating, and increasing/decreasing the temperature or time of standing of said solution to increase/decrease the pore size of said coating; and curing said deposited film at a temperature effective for curing whereby there is obtained a thin film coating of a predetermined porosity on the substrate.
NASA Astrophysics Data System (ADS)
Azizah, N.; Hashim, U.; Arshad, M. K. Md.; Gopinath, Subash C. B.; Nadzirah, Sh.; Farehanim, M. A.; Fatin, M. F.; Ruslinda, A. R.; Ayub, R. M.
2016-07-01
Titanium dioxide (TiO2) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO2 was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to an acid solution. Amine and oxide functionalized TiO2 based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO2 based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO2 based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.
Gradient-free determination of isoelectric points of proteins on chip.
Łapińska, Urszula; Saar, Kadi L; Yates, Emma V; Herling, Therese W; Müller, Thomas; Challa, Pavan K; Dobson, Christopher M; Knowles, Tuomas P J
2017-08-30
The isoelectric point (pI) of a protein is a key characteristic that influences its overall electrostatic behaviour. The majority of conventional methods for the determination of the isoelectric point of a molecule rely on the use of spatial gradients in pH, although significant practical challenges are associated with such techniques, notably the difficulty in generating a stable and well controlled pH gradient. Here, we introduce a gradient-free approach, exploiting a microfluidic platform which allows us to perform rapid pH change on chip and probe the electrophoretic mobility of species in a controlled field. In particular, in this approach, the pH of the electrolyte solution is modulated in time rather than in space, as in the case for conventional determinations of the isoelectric point. To demonstrate the general approachability of this platform, we have measured the isoelectric points of representative set of seven proteins, bovine serum albumin, β-lactoglobulin, ribonuclease A, ovalbumin, human transferrin, ubiquitin and myoglobin in microlitre sample volumes. The ability to conduct measurements in free solution thus provides the basis for the rapid determination of isoelectric points of proteins under a wide variety of solution conditions and in small volumes.
Dynamics of human serum albumin studied by acoustic relaxation spectroscopy.
Hushcha, T; Kaatze, U; Peytcheva, A
Sonic absorption spectra of solutions of human serum albumin (SA) in water and in aqueous phosphate buffer systems have been measured between 0.2 and 2000 MHz at different temperatures (15-35 degrees C), pH values (1.8-12.3), and protein concentrations (1-40 g/L). Several spectra, indicating relaxation processes in the whole frequency range, have been found. The spectra at neutral pH could be fitted well with an analytical function consisting of the asymptotic high frequency absorption and two relaxation contributions, a Debye-type relaxation term with discrete relaxation time and a term with asymmetric continuous distribution of relaxation times. Both relaxation contributions were observed in water and in buffer solutions and increased with protein concentration. The contribution represented by a Debye-type term is practically independent of temperature and was attributed to cooperative conformational changes of the polypeptide chain featuring a relaxation time of about 400 ns. The distribution of the relaxation times corresponding to the second relaxation contribution was characterized by a short time cutoff, between about 0.02 and 0.4 ns depending on temperature, and a long time tail extending to microseconds. Such relaxation behavior was interpreted in terms of solute-solvent interactions reflecting various hydration layers of HSA molecules. At acid and alkaline pH, an additional Debye-type contribution with relaxation time in the range of 30-100 ns exists. It seems to be due to proton transfer reactions of protein side-chain groups. The kinetic and thermodynamic parameters of these processes have been estimated from these first measurements to indicate the potential of acoustic spectra for the investigation of the elementary kinetics of albumin processes. Copyright 2004 Wiley Periodicals, Inc. Biopolymers, 2004
Chantasart, Doungdaw; Chootanasoontorn, Siriwan; Suksiriworapong, Jiraphong; Li, S Kevin
2015-10-01
As a continuing effort to understand the skin permeation behavior of weak acids and bases, the objectives of the present study were to evaluate skin permeation of nonsteroidal anti-inflammatory drugs (NSAIDs) under the influence of pH, investigate the mechanism of pH effect, and examine a previous hypothesis that the effective skin pH for drug permeation is different from donor solution pH. In vitro permeability experiments were performed in side-by-side diffusion cells with diclofenac, ibuprofen, flurbiprofen, ketoprofen, and naproxen and human skin. The donor solution pH significantly affected skin permeation of NSAIDs, whereas no effect of the receiver pH was observed. Similar to previous observations, the apparent permeability coefficient versus donor solution pH relationships deviated from the predictions (fractions of unionized NSAIDs) according to the acid/base theory. The influences of the viable epidermis barrier, polar pathway transport, ion permeation across skin, and effective skin pH were investigated. The effective pH values for skin permeation determined using the NSAIDs (weak acids) in this study were different from those obtained previously with a weak base at the same donor solution pH conditions, suggesting that the observed permeability-pH relationships could not be explained solely by possible pH differences between skin and donor solution. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Prediction of equilibrium parameters of adsorption of lead (II) ions onto diatomite
NASA Astrophysics Data System (ADS)
Salman, Taylan; Ardalı, Yüksel; Gamze Turan, N.
2013-04-01
Heavy metals from industrial wastewaters are one of the most important environmental issues to be solved today. Due to their toxicity and nonbiodegradable nature, heavy metals cause environmental and public health problems. Various techniques have been developed to remove heavy metals from aqueous solutions. These include chemical precipitation, reverse osmosis, ion Exchange and adsorption. Among them, adsorption is considered to be a particularly competitive and effective process for the removal of heavy metals from aqueous solutions. There is growing interest in using low cost, commercially available materials for the adsorption of heavy metals. Diatomite is a siliceous sedimentary rock having an amorphous form of silica (SiO2. nH2O) containing a small amount of microcrystalline material. It has unique combination of physical and chemical properties such as high porosity, high permeability, small particle size, large surface area, and low thermal conductivity. In addition, it is available in Turkey and in various locations around the world. Therefore, diatomite has been successfully used as adsorbent for the removal of heavy metals. The aim of the study is to investigate the adsorption properties of diatomite. The equilibrium adsorption data were applied to the Langmuir, Freundlich and Dubinin-Radushkevic (D-R) isotherm models. Adsorption experiments were performed under batch process, using Pb (II) initial concentration, pH of solution and contact time as variables. The results demonstrated that the adsorption of Pb (II) was strongly dependent on pH of solution. The effect of pH on adsorption of Pb(II) on diatomite was conducted by varying pH from 2 to 12 at 20 oC. In the pH range of 2.0-4.0, the adsorption percentage increases slightly as the pH increasing. At pH>4, the adsorption percentage decreases with increasing pH because hydrolysis product and the precipitation begin to play an important role in the sorption of Pb (II). At pH4, the maximum adsorption capacity of diatomite was found as 26.158 mg/g. The adsorption isotherms of Pb (II) on diatomite can be described well by the Freundlich model. The high adsorption capacity of diatomite makes it suitable low-cost material in the removal of Pb (II) from aqueous solutions.
The effect of pH on phosphorus availability and speciation in an aquaponics nutrient solution.
Cerozi, Brunno da Silva; Fitzsimmons, Kevin
2016-11-01
The interaction between the main ions in aquaponics nutrient solutions affects chemical composition and availability of nutrients, and nutrient uptake by plant roots. This study determined the effect of pH on phosphorus (P) speciation and availability in an aquaponics nutrient solution and used Visual MINTEQ to simulate P species and P activity. In both experimental and simulated results, P availability decreased with increase in pH of aquaponics nutrient solutions. According to simulations, P binds to several cations leaving less free phosphate ions available in solution. High pH values resulted in the formation of insoluble calcium phosphate species. The study also demonstrated the importance of organic matter and alkalinity in keeping free phosphate ions in solution at high pH ranges. It is recommended though that pH in aquaponics systems is maintained at a 5.5-7.2 range for optimal availability and uptake by plants. Copyright © 2016 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 4.0 with pH 4.0 buffer and pH 7 with pH 7.0 buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3... hydrochloride solution, 100 grams per liter, pH adjusted to 4.00. 4.3Hydrochloric acid solution, 1.0 N and 0.1 N... magnetic stirrer. Confirm that the resin has dissolved. 5.4Adjust the resin/solvent solution to pH 4.0...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 4.0 with pH 4.0 buffer and pH 7 with pH 7.0 buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3... hydrochloride solution, 100 grams per liter, pH adjusted to 4.00. 4.3Hydrochloric acid solution, 1.0 N and 0.1 N... magnetic stirrer. Confirm that the resin has dissolved. 5.4Adjust the resin/solvent solution to pH 4.0...
NASA Astrophysics Data System (ADS)
Tabata, H.; Sekine, Y.; Kanzaki, Y.; Sugita, S.; Murakami, T.
2017-12-01
Geochemical evidence obatined by Mars Opportunity rover suggests that the pH of Martian surface water shifted to highly acidic, i.e., pH 2-4, in the early Hesperian (e.g., Tosca et al., 2005). Hurowitz et al. (2010) proposed that solar UV light may have promoted the acidification through photo-oxidation of ferrous iron dissolved in upwelling groundwater on early Mars. However, the trigger for the acidification in the early Hesperian remains unclear. The photo-oxidation of Fe2+ occurs under acidic conditions, i.e., pH < 3 (Jortner et al., 1962); however, the pH of upwelling groundwater would be neutral to alkaline (Zolotov et al., 2016). At neutral to alkaline pH, FeOH+ can exist together with Fe2+ in a solution. While both Fe2+ and FeOH+ are photo-oxidized only by UV light (< 300 nm), FeOH+ can also be photo-oxidized by long UV/visible light (300-400 nm). Thus, the efficiency of acidification through photo-oxidation on early Mars should have depended on the solar spectrum on the surface at that time which is determined by the atmospheric composition. To investigate the effect of UV spectrum on the acidification, we conducted two types of laboratory experiments: One used a Xe lamp as the light source for photo-oxidation of ferrous iron to irradiate light with continuous spectrum from 250 to 400 nm, and the other used the Xe lamp with an optical filter that cuts off UV light shorter than 300 nm. The pH value of the starting solution was around 7. Upon the UV irradiation covering full wavelength range (250-400 nm), the pH value of the solution decreases down to less than 4, consistent with the proposed pH of the Hesperian acidic water on Meridiani Planum (Tosca et al., 2005). This occurs because Fe2+ is stable at pH < 5, and because Fe2+ can be continuously photo-oxidized in the acidic solution by UV light in 250-300 nm. When the UV irradiation covering 300-400 nm, the pH value of the solution also decreases to pH 5 immediately after the UV irradiation. However, it does not decrease less than pH 5 and reaches a steady state. This is the case because FeOH+ is converted into Fe2+ at low pH, which prevents further photo-oxidation by light in 300-400 nm. These results suggest that a change in the atmospheric composition and consequent reaching of UV light in the wavelength < 300 nm may have played a key role for triggering the acidification in the early Hesperian.
Scaling theory in a model of corrosion and passivation.
Aarão Reis, F D A; Stafiej, Janusz; Badiali, J-P
2006-09-07
We study a model for corrosion and passivation of a metallic surface after small damage of its protective layer using scaling arguments and simulation. We focus on the transition between an initial regime of slow corrosion rate (pit nucleation) to a regime of rapid corrosion (propagation of the pit), which takes place at the so-called incubation time. The model is defined in a lattice in which the states of the sites represent the possible states of the metal (bulk, reactive, and passive) and the solution (neutral, acidic, or basic). Simple probabilistic rules describe passivation of the metal surface, dissolution of the passive layer, which is enhanced in acidic media, and spatially separated electrochemical reactions, which may create pH inhomogeneities in the solution. On the basis of a suitable matching of characteristic times of creation and annihilation of pH inhomogeneities in the solution, our scaling theory estimates the average radius of the dissolved region at the incubation time as a function of the model parameters. Among the main consequences, that radius decreases with the rate of spatially separated reactions and the rate of dissolution in acidic media, and it increases with the diffusion coefficient of H(+) and OH(-) ions in solution. The average incubation time can be written as the sum of a series of characteristic times for the slow dissolution in neutral media, until significant pH inhomogeneities are observed in the dissolved cavity. Despite having a more complex dependence on the model parameters, it is shown that the average incubation time linearly increases with the rate of dissolution in neutral media, under the reasonable assumption that this is the slowest rate of the process. Our theoretical predictions are expected to apply in realistic ranges of values of the model parameters. They are confirmed by numerical simulation in two-dimensional lattices, and the expected extension of the theory to three dimensions is discussed.
Saavedra, Ricardo; Muñoz, Raúl; Taboada, María Elisa; Vega, Marisol; Bolado, Silvia
2018-04-26
This work represents a comparative uptake study of the toxic elements arsenic, boron, copper, manganese and zinc in monometallic and multimetallic solutions by four green microalgae species (Chlamydomonas reinhardtii, Chlorella vulgaris, Scenedesmus almeriensis and an indigenous Chlorophyceae spp.), evaluating the effect of pH and contact time. Maximum removal efficiencies for each toxic element were 99.4% for Mn (C. vulgaris, pH 7.0, 3 h), 91.9% for Zn (Chlorophyceae spp., pH 5.5, 3 h), 88% for Cu (Chlorophyceae spp., pH 7.0, 10 min), 40.7% for As (S. almeriensis, pH 9.5, 3 h) and 38.6% for B (S. almeriensis, pH 5.5, 10 min). B removal efficiencies decreased remarkably in multimetallic solutions (down to 0.2% in C. reinhardtii), except for Chlorophyceae spp., the only species isolated from a polluted environment. FTIR spectra shown the highest interactions for As (1150-1300 cm -1 ) and Cu (3300, 1741, 1535, 1350-1400 cm -1 ). Results confirm microalgae biomass as a potential biosorbent for toxic elements. Copyright © 2018 Elsevier Ltd. All rights reserved.
Effects of acidic pH on voltage-gated ion channels in rat trigeminal mesencephalic nucleus neurons.
Han, Jin-Eon; Cho, Jin-Hwa; Choi, In-Sun; Kim, Do-Yeon; Jang, Il-Sung
2017-03-01
The effects of acidic pH on several voltage-dependent ion channels, such as voltage-dependent K + and Ca 2+ channels, and hyperpolarization-gated and cyclic nucleotide-activated cation (HCN) channels, were examined using a whole-cell patch clamp technique on mechanically isolated rat mesencephalic trigeminal nucleus neurons. The application of a pH 6.5 solution had no effect on the peak amplitude of voltage-dependent K + currents. A pH 6.0 solution slightly, but significantly inhibited the peak amplitude of voltage-dependent K + currents. The pH 6.0 also shifted both the current-voltage and conductance-voltage relationships to the depolarization range. The application of a pH 6.5 solution scarcely affected the peak amplitude of membrane currents mediated by HCN channels, which were profoundly inhibited by the general HCN channel blocker Cs + (1 mM). However, the pH 6.0 solution slightly, but significantly inhibited the peak amplitude of HCN-mediated currents. Although the pH 6.0 solution showed complex modulation of the current-voltage and conductance-voltage relationships, the midpoint voltages for the activation of HCN channels were not changed by acidic pH. On the other hand, voltage-dependent Ca 2+ channels were significantly inhibited by an acidic pH. The application of an acidic pH solution significantly shifted the current-voltage and conductance-voltage relationships to the depolarization range. The modulation of several voltage-dependent ion channels by an acidic pH might affect the excitability of mesencephalic trigeminal nucleus neurons, and thus physiological functions mediated by the mesencephalic trigeminal nucleus could be affected in acidic pH conditions.
Adsorption performance of mixed dyes on alkalization loofah fibers
NASA Astrophysics Data System (ADS)
Wang, Yongli; Liu, Jinyan; Li, Xingxing
2018-02-01
When the polyporous structures of loofah fiber is adequately exposed after alkali treatment,lignin, hemicellulose and pectin are removed. Specific surface area is increased to maximum, which means the efficiency of absorptivity is highest. In this paper, by using alkalization loofah (AL) as adsorbent, the effect of loofah fiber on waste water treatment is studied under the efficiency of loofah fiber which contain acridine yellow, methylene blue, mixed solution of the two dyes. The optimum treatment conditions of loofah fiber were studied from five aspects which include dosage, temperature, mixing time, pH and concentration. The results showed that the optimal conditions are 30°C, pH 8.0, 20mg dosage of loofah fiber in 40ml solution and mixing time 25min. The optimal treatment conditions of mixed dyes were studied from the aspects of mixing time, the dosage of AL and the molar ratio of the two components in the mixed dyes.
Measurements of spectral responses for developing fiber-optic pH sensor
NASA Astrophysics Data System (ADS)
Yoo, Wook Jae; Heo, Ji Yeon; Jang, Kyoung Won; Seo, Jeong Ki; Moon, Jin Soo; Park, Jang-Yeon; Park, Byung Gi; Cho, Seunghyun; Lee, Bongsoo
2011-01-01
In this study, we have fabricated a fiber-optic pH sensor, which is composed of a light source, a pH-sensing probe, plastic optical fibers and a spectrometer, for determining the degree of infection by Helicobacter pylori in the stomach. As pH indicators, phenol red and m-cresol purple are used, and pH liquid solutions are prepared by mixing phenol red or m-cresol purple solutions and various kinds of pH buffer solutions. The light emitted by a light source is guided by plastic optical fibers to the pH liquid solution, and the optical characteristic of a reflected light is changed according to the color variations of the pH indicator in the pH-sensing probe. Therefore, we have measured the intensities and wavelength shifts of the reflected lights, which change according to the color variations of indicators at different pH values, by using a spectrometer for spectral analysis. Also, the relationships between the pH values of liquid solutions and the optical properties of the modulated lights are obtained on the basis of the changes of the colors of indicators.
Adsorption of Cu(II) from aqueous solution on sulfuric acid treated palygorskite
NASA Astrophysics Data System (ADS)
Niu, Yan-Ning; Yuan, Yuan; Gao, Wei-Xin; Qian, Sheng; Sun, Wen
2018-03-01
The absorption behavior of Cu2+ from aqueous solution on sulfuric acid treated palygorskite were investigated, the results showed that palygorskite had high absorption ability for Cu2+ from aqueous solution. Effects of the shaking time, pH and the copper ion concentration on the removal rate were discussed. The absorption behavior of Cu2+ could be well imitated by the Langmuir isothermal equation.
NASA Astrophysics Data System (ADS)
Deng, Zhigan; Wei, Chang; Fan, Gang; Li, Xingbin; Li, Minting; Li, Cunxiong
2018-02-01
Nickel was separated and precipitated with potassium nickel sulfate hexahydrate [K2Ni(SO4)2·6H2O] from acidic sulfate solution, a leach solution from molybdenum-nickel black shale. The effects of the potassium sulfate (K2SO4) concentration, crystallization temperature, solution pH, and crystallization time on nickel(II) recovery and iron(III) precipitation were investigated, revealing that nickel and iron were separated effectively. The optimum parameters were K2SO4 concentration of 200 g/L, crystallization temperature of 10°C, solution pH of 0.5, and crystallization time of 24 h. Under these conditions, 97.6% nickel(II) was recovered as K2Ni(SO4)2·6H2O crystals while only 2.0% of the total iron(III) was precipitated. After recrystallization, 98.4% pure K2Ni(SO4)2·6H2O crystals were obtained in the solids. The mother liquor was purified by hydrolysis-precipitation followed by cooling, and more than 99.0% K2SO4 could be crystallized. A process flowsheet was developed to separate iron(III) and nickel(II) from acidic-sulfate solution.
Singh, Kunwar P; Gupta, Shikha; Ojha, Priyanka; Rai, Premanjali
2013-04-01
The research aims to develop artificial intelligence (AI)-based model to predict the adsorptive removal of 2-chlorophenol (CP) in aqueous solution by coconut shell carbon (CSC) using four operational variables (pH of solution, adsorbate concentration, temperature, and contact time), and to investigate their effects on the adsorption process. Accordingly, based on a factorial design, 640 batch experiments were conducted. Nonlinearities in experimental data were checked using Brock-Dechert-Scheimkman (BDS) statistics. Five nonlinear models were constructed to predict the adsorptive removal of CP in aqueous solution by CSC using four variables as input. Performances of the constructed models were evaluated and compared using statistical criteria. BDS statistics revealed strong nonlinearity in experimental data. Performance of all the models constructed here was satisfactory. Radial basis function network (RBFN) and multilayer perceptron network (MLPN) models performed better than generalized regression neural network, support vector machines, and gene expression programming models. Sensitivity analysis revealed that the contact time had highest effect on adsorption followed by the solution pH, temperature, and CP concentration. The study concluded that all the models constructed here were capable of capturing the nonlinearity in data. A better generalization and predictive performance of RBFN and MLPN models suggested that these can be used to predict the adsorption of CP in aqueous solution using CSC.
Milenković, Aleksandra S; Smičiklas, Ivana D; Šljivić-Ivanović, Marija Z; Živković, Ljiljana S; Vukelić, Nikola S
2016-07-02
The prospects of rinsed red mud (alumina production residue) utilization for liquid radioactive waste treatment have been investigated, with Co(2+) and Sr(2+) as model cations of radioactive elements. To evaluate the sorption effectiveness and corresponding binding mechanisms, the process was analyzed in batch conditions, by varying experimental conditions (pH, Co(2+) and Sr(2+) concentrations in single solutions and binary mixtures, contact time, and the concentration of competing cations and ligands common in liquid radioactive waste). Comparison of the Co(2+) and Sr(2+) sorption pH edges with the red mud isoelectric point has revealed that Co(2+) removal took place at both positive and negative red mud surface, while Sr(2+) sorption abruptly increased when the surface became negatively charged. The increase of initial cation content and pH resulted in increased equilibrium times and sorption capacity and decreased rate constants. From single metal solutions and various binary mixtures, Co(2+) was sorbed more efficiently and selectively than Sr(2+). While Sr(2+) sorption was reduced by coexisting cations in the order Al(3+) ≥ Ca(2+) >Na(+) ≥Cs(+), removal of Co(2+) was affected by Al(3+) species and complexing agents (EDTA and citrate). Desorption of Co(2+) was negligible in Ca(2+) and Sr(2+) containing media and in solutions with initial pH 4-7. Sr(2+) desorption was generally more pronounced, especially at low pH and in the presence of Co(2+). Collected macroscopic data signify that Co(2+) sorption by red mud minerals occurred via strong chemical bonds, while Sr(2+) was retained mainly by weaker ion-exchange or electrostatic interactions. Results indicate that the rinsed red mud represent an efficient, low-cost sorbent for Co(2+) and Sr(2+) immobilization.
Lv, Xia; Liu, Tiantian; Ma, Huipeng; Tian, Yan; Li, Lei; Li, Zhen; Gao, Meng; Zhang, Jianbin; Tang, Zeyao
2017-11-01
Quercetin can bring many benefits to skin based on its various bioactivities. However, the therapeutic effect of quercetin is limited due to the poor water solubility, pH instability, light instability, and skin permeation. The aim of the present work was applying essential oil-based microemulsions to improve the solubility, pH stability, photostability, and skin permeation of quercetin for topical application. Peppermint oil (PO-ME), clove oil (CO-ME), and rosemary oil (RMO-ME) were selected as model essential oils. Microemulsions composed of Cremophor EL/1,2-propanediol/essential oils (47:23:30, w/w) were selected as model formulations, based on the pseudo-ternary phase diagram and the characterizations. In the solubility study, the solubility of quercetin was improved dozens of times by microemulsions. Quercetin was found instable under alkaline condition, with 50% degraded in the solution of pH 13. However, PO-ME, CO-ME, and RMO-ME could protect quercetin from the hydroxide ions, with 47, 9, and 12% of quercetin degraded. In the photostability study, the essential oil-based microemulsions showed the capability of protecting quercetin from degradation under UV radiation. Where more than 67% of quercetin was degraded in aqueous solution, while less than 7% of quercetin degraded in microemulsions. At last, the in vitro skin permeation study showed that the essential oil-based microemulsions could enhance the permeation capacity of quercetin by 2.5-3 times compared to the aqueous solution. Hence, the prepared essential oil microemulsions could improve the solubility, pH stability, photostability, and skin permeation of quercetin, which will be beneficial for its topical application.
A method for calibrating pH meters using standard solutions with low electrical conductivity
NASA Astrophysics Data System (ADS)
Rodionov, A. K.
2011-07-01
A procedure for obtaining standard solutions with low electrical conductivity that reproduce pH values both in acid and alkali regions is proposed. Estimates of the maximal possible error of reproducing the pH values of these solutions are obtained.
40 CFR 467.34 - New source performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of 7.0 to 10.0 at all times. Subpart C Solution Heat Treatment Contact Cooling Water Pollutant or... the pH shall be within the range of 6.0 to 10.0 at all times. Subpart C Press Heat Treatment Contact...
40 CFR 467.34 - New source performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of 7.0 to 10.0 at all times. Subpart C Solution Heat Treatment Contact Cooling Water Pollutant or... the pH shall be within the range of 6.0 to 10.0 at all times. Subpart C Press Heat Treatment Contact...
NASA Astrophysics Data System (ADS)
Pokrovsky, O. S.; Viers, J.; Emnova, E. E.; Kompantseva, E. I.; Freydier, R.
2008-04-01
This work is aimed at quantifying the main environmental factors controlling isotope fractionation of Cu during its adsorption from aqueous solutions onto common organic (bacteria, algae) and inorganic (oxy(hydr)oxide) surfaces. Adsorption of Cu on aerobic rhizospheric ( Pseudomonas aureofaciens CNMN PsB-03) and phototrophic aquatic ( Rhodobacter sp. f-7bl, Gloeocapsa sp. f-6gl) bacteria, uptake of Cu by marine ( Skeletonema costatum) and freshwater ( Navicula minima, Achnanthidium minutissimum and Melosira varians) diatoms, and Cu adsorption onto goethite (FeOOH) and gibbsite (AlOOH) were studied using a batch reaction as a function of pH, copper concentration in solution and time of exposure. Stable isotopes of copper in selected filtrates were measured using Neptune multicollector ICP-MS. Irreversible incorporation of Cu in cultured diatom cells at pH 7.5-8.0 did not produce any isotopic shift between the cell and solution (Δ 65/63Cu(solid-solution)) within ±0.2‰. Accordingly, no systematic variation was observed during Cu adsorption on anoxygenic phototrophic bacteria ( Rhodobacter sp.), cyanobacteria ( Gloeocapsa sp.) or soil aerobic exopolysaccharide (EPS)-producing bacteria ( P. aureofaciens) in circumneutral pH (4-6.5) and various exposure times (3 min to 48 h): Δ 65Cu(solid-solution) = 0.0 ± 0.4‰. In contrast, when Cu was adsorbed at pH 1.8-3.5 on the cell surface of soil the bacterium P. aureofacienshaving abundant or poor EPS depending on medium composition, yielded a significant enrichment of the cell surface in the light isotope (Δ 65Cu (solid-solution) = -1.2 ± 0.5‰). Inorganic reactions of Cu adsorption at pH 4-6 produced the opposite isotopic offset: enrichment of the oxy(hydr)oxide surface in the heavy isotope with Δ 65Cu(solid-solution) equals 1.0 ± 0.25‰ and 0.78 ± 0.2‰ for gibbsite and goethite, respectively. The last result corroborates the recent works of Mathur et al. [Mathur R., Ruiz J., Titley S., Liermann L., Buss H. and Brantley S. (2005) Cu isotopic fractionation in the supergene environment with and without bacteria. Geochim. Cosmochim. Acta69, 5233-5246] and Balistrieri et al. [Balistrieri L. S., Borrok D. M., Wanty R. B. and Ridley W. I. (2008) Fractionation of Cu and Zn isotopes during adsorption onto amorhous Fe(III) oxyhydroxide: experimental mixing of acid rock drainage and ambient river water. Geochim. Cosmochim. Acta72, 311-328] who reported heavy Cu isotope enrichment onto amorphous ferric oxyhydroxide and on metal hydroxide precipitates on the external membranes of Fe-oxidizing bacteria, respectively. Although measured isotopic fractionation does not correlate with the relative thermodynamic stability of surface complexes, it can be related to their structures as found with available EXAFS data. Indeed, strong, bidentate, inner-sphere complexes presented by tetrahedrally coordinated Cu on metal oxide surfaces are likely to result in enrichment of the heavy isotope on the surface compared to aqueous solution. The outer-sphere, monodentate complex, which is likely to form between Cu 2+ and surface phosphoryl groups of bacteria in acidic solutions, has a higher number of neighbors and longer bond distances compared to inner-sphere bidentate complexes with carboxyl groups formed on bacterial and diatom surfaces in circumneutral solutions. As a result, in acidic solution, light isotopes become more enriched on bacterial surfaces (as opposed to the surrounding aqueous medium) than they do in neutral solution. Overall, the results of the present study demonstrate important isotopic fractionation of copper in both organic and inorganic systems and provide a firm basis for using Cu isotopes for tracing metal transport in earth-surface aquatic systems. It follows that both adsorption on oxides in a wide range of pH values and adsorption on bacteria in acidic solutions are capable of producing a significant (up to 2.5-3‰ (±0.1-0.15‰)) isotopic offset. At the same time, Cu interaction with common soil and aquatic bacteria, as well as marine and freshwater diatoms, at 4 < pH < 8 yields an isotopic shift of only ±0.2-0.3‰, which is not related to Cu concentration in solution, surface loading, the duration of the experiment, or the type of aquatic microorganisms.
Removal of ammonium from aqueous solutions with volcanic tuff.
Marañón, E; Ulmanu, M; Fernández, Y; Anger, I; Castrillón, L
2006-10-11
This paper presents kinetic and equilibrium data concerning ammonium ion uptake from aqueous solutions using Romanian volcanic tuff. The influence of contact time, pH, ammonium concentration, presence of other cations and anion species is discussed. Equilibrium isotherms adequately fit the Langmuir and Freundlich models. The results showed a contact time of 3h to be sufficient to reach equilibrium and pH of 7 to be the optimum value. Adsorption capacities of 19 mg NH(4)(+)/g were obtained in multicomponent solutions (containing NH(4)(+), Zn(2+), Cd(2+), Ca(2+), Na(2+)). The presence of Zn and Cd at low concentrations did not decrease the ammonium adsorption capacity. Comparison of Romanian volcanic tuff with synthetic zeolites used for ammonium removal (5A, 13X and ZSM-5) was carried out. The removal efficiciency of ammonium by volcanic tuff were similar to those of zeolites 5A and 13X at low initial ammonium concentration, and much higher than those of zeolite ZSM-5.
Statistical analysis and isotherm study of uranium biosorption by Padina sp. algae biomass.
Khani, Mohammad Hassan
2011-06-01
The application of response surface methodology is presented for optimizing the removal of U ions from aqueous solutions using Padina sp., a brown marine algal biomass. Box-Wilson central composite design was employed to assess individual and interactive effects of the four main parameters (pH and initial uranium concentration in solutions, contact time and temperature) on uranium uptake. Response surface analysis showed that the data were adequately fitted to second-order polynomial model. Analysis of variance showed a high coefficient of determination value (R (2)=0.9746) and satisfactory second-order regression model was derived. The optimum pH and initial uranium concentration in solutions, contact time and temperature were found to be 4.07, 778.48 mg/l, 74.31 min, and 37.47°C, respectively. Maximized uranium uptake was predicted and experimentally validated. The equilibrium data for biosorption of U onto the Padina sp. were well represented by the Langmuir isotherm, giving maximum monolayer adsorption capacity as high as 376.73 mg/g.
Kynicky, Jindrich; Adam, Vojtech
2017-01-01
The microwave-assisted synthesis of goethite nanoparticles has been studied. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA) and Brunauer–Emmett–Teller (BET) method. Goethite rod-like nanoparticles have been successfully synthesized in 10 min of microwave treating at 100 °C. Particle size is in the range from 30 to 60 nm in width and from 200 to 350 nm in length. BET analysis indicated that the surface area of the product is 158.31 m2g−1. The feasibility of Cr(VI) removal fromaqueous solution depends on the pH of the solution and contact time. The maximum adsorptionis reached at pH 4.0 and 540 min of contact time. The adsorption kinetics was analyzedby the pseudo-first- and second-order models and the results reveal that the adsorption process obeys the pseudo-second-order model. The adsorption data were fitted well with the Langmuir adsorption isotherm. PMID:28773142
Burkholder, Paul R.
1933-01-01
The effect of pH upon the velocity of translatory movement of Oscillatoria formosa Bory in inorganic culture solutions was determined. Unhindered movement occurred in the range of about pH 6.4 to 9.5. Above and below these limits inhibition was marked. In the unfavorable acid and alkaline ranges inhibition was progressive with exposure time; in the favorable range continuous movement was maintained for 24 hours. PMID:19872745
Electrochemical control of pH in a hydroponic nutrient solution
NASA Technical Reports Server (NTRS)
Schwartzkopf, S. H.
1986-01-01
The electrochemical pH control system described was found to provide a feasible alternative method of controlling nutrient solution pH for CELSS applications. The plants grown in nutrient solution in which the pH was controlled electrochemically showed no adverse effects. Further research into the design of a larger capacity electrode bridge for better control is indicated by the results of this experiment, and is currently under way.
Zobel, C. Richard; Beer, Michael
1961-01-01
Chemical studies have been carried out on the interaction of DNA with uranyl salts. The effect of variations in pH, salt concentration, and structural integrity of the DNA on the stoichiometry of the salt-substrate complex have been investigated. At pH 3.5 DNA interacts with uranyl ions in low concentration yielding a substrate metal ion complex with a UO2++/P mole ratio of about ½ and having a large association constant. At low pH's (about 2.3) the mole ratio decreases to about ⅓. Destruction of the structural integrity of the DNA by heating in HCHO solutions leads to a similar drop in the amount of metal ion bound. Raising the pH above 3.5 leads to an apparent increase in binding as does increasing the concentration of the salt solution. This additional binding has a lower association constant. Under similar conditions DNA binds about seven times more uranyl ion than bovine serum albumin, indicating useful selectivity in staining for electron microscopy. PMID:13788706
NASA Astrophysics Data System (ADS)
Sambaza, Shepherd S.; Masheane, Monaheng L.; Malinga, Soraya P.; Nxumalo, Edward N.; Mhlanga, Sabelo D.
2017-08-01
This work reports on the synthesis of multi-walled carbon nanotubes (MWCNTs) and their use in branched polyethyleneimine-multiwalled carbon nanotube (PEI-MWCNT) polymeric nanocomposite adsorbents for the removal of Cr6+ from contaminated water. The nanostructured materials were characterized using TEM, Raman, FTIR, BET surface area and zeta potential measurements. TEM confirmed the average diameter of the MWCNTs to be 25 nm. The point of zero-charge of PEI was at pH 8 and that of PEI-MWCNTs was at pH 7.7. FTIR analysis confirmed the formation of a new bond (-Cdbnd O at 1716 cm-1) between the functional groups on the MWCNTs and PEI. Batch adsorption and kinetic studies showed that the PEI-MWCNT nanocomposite materials were more efficient in the removal of Cr6+ solution from water samples. The optimum conditions for adsorption were pH ≤ 4, contact time of 60 min. When the PEI-MWCNT dosage was increased the adsorption capacity increased. The kinetic adsorption data obtained for Cr6+ solution followed pseudo-second order model. The adsorption of Cr6+ solution reached equilibrium within 60 min of contact time with a removal of 99%. The adsorbents were effective even after 5 cycles of use.
Modeling the chemical kinetics of atmospheric plasma for cell treatment in a liquid solution
NASA Astrophysics Data System (ADS)
Kim, H. Y.; Lee, H. W.; Kang, S. K.; Wk. Lee, H.; Kim, G. C.; Lee, J. K.
2012-07-01
Low temperature atmospheric pressure plasmas have been known to be effective for living cell inactivation in a liquid solution but it is not clear yet which species are key factors for the cell treatment. Using a global model, we elucidate the processes through which pH level in the solution is changed from neutral to acidic after plasma exposure and key components with pH and air variation. First, pH level in a liquid solution is changed by He+ and He(21S) radicals. Second, O3 density decreases as pH level in the solution decreases and air concentration decreases. It can be a method of removing O3 that causes chest pain and damages lung tissue when the density is very high. H2O2, HO2, and NO radicals are found to be key factors for cell inactivation in the solution with pH and air variation.
Uptake of Cr3+ from aqueous solution by lignite-based humic acids.
Arslan, G; Pehlivan, E
2008-11-01
Humic acid (HA) produced from brown coal, a relatively abundant and inexpensive material is currently being investigated as an adsorbent to remove toxic metals from aqueous solution. The influence of five parameters (contact time, solution pH, initial metal concentration, temperature and amount of adsorbent) on the removal at 20+/-1 degrees C was studied. HAs were prepared from lignites by using alkaline extraction, sedimentation and acidic precipitation. Adsorption equilibrium was achieved in about 60 min for Cr3+ ion. The Langmuir adsorption isotherm was used to describe observed sorption phenomena. The maximum adsorption capacity of 0.17 mmol for Ilgin (HA1), 0.29 mmol for Beysehir (HA2) and 0.18 mmol Ermenek (HA3) and 0.17 mmol of Cr3+/g for activated carbon (AC) was achieved, respectively at pH of 4.1. More than 84% of Cr3+ was removed by HA2, 54% by HA3 and 51% by HA1 and 50% by AC from aqueous solution. The adsorption was strongly dependent on pH but independent of ionic strength and metal ions. The adsorption of Cr3+ was higher between pH 4.1 and 5.1 for all HAs and maximum sorption was observed at pH 4.1. The rise in temperature caused a slight decrease in the value of the equilibrium constant (Kc) for the sorption of Cr3+ ion. Complex mechanisms including ion exchange, complexation and adsorption and size exclusion are possible for sorption of Cr3+ ion on HAs.
Anti-inflammatory activity of nanocrystalline silver-derived solutions in porcine contact dermatitis
2010-01-01
Background Nanocrystalline silver dressings have anti-inflammatory activity, unlike solutions containing Ag+ only, which may be due to dissolution of multiple silver species. These dressings can only be used to treat surfaces. Thus, silver-containing solutions with nanocrystalline silver properties could be valuable for treating hard-to-dress surfaces and inflammatory conditions of the lungs and bowels. This study tested nanocrystalline silver-derived solutions for anti-inflammatory activity. Methods Inflammation was induced on porcine backs using dinitrochlorobenzene. Negative and positive controls were treated with distilled water. Experimental groups were treated with solutions generated by dissolving nanocrystalline silver in distilled water adjusted to starting pHs of 4 (using CO2), 5.6 (as is), 7, and 9 (using Ca(OH)2). Solution samples were analyzed for total silver. Daily imaging, biopsying, erythema and oedema scoring, and treatments were performed for three days. Biopsies were processed for histology, immunohistochemistry (for IL-4, IL-8, IL-10, TNF-α, EGF, KGF, KGF-2, and apoptotic cells), and zymography (MMP-2 and -9). One-way ANOVAs with Tukey-Kramer post tests were used for statistical analyses. Results Animals treated with pH 7 and 9 solutions showed clear visual improvements. pH 9 solutions resulted in the most significant reductions in erythema and oedema scores. pH 4 and 7 solutions also reduced oedema scores. Histologically, all treatment groups demonstrated enhanced re-epithelialisation, with decreased inflammation. At 24 h, pMMP-2 expression was significantly lowered with pH 5.6 and 9 treatments, as was aMMP-2 expression with pH 9 treatments. In general, treatment with silver-containing solutions resulted in decreased TNF-α and IL-8 expression, with increased IL-4, EGF, KGF, and KGF-2 expression. At 24 h, apoptotic cells were detected mostly in the dermis with pH 4 and 9 treatments, nowhere with pH 5.6, and in both the epidermis and dermis with pH 7. Solution anti-inflammatory activity did not correlate with total silver content, as pH 4 solutions contained significantly more silver than all others. Conclusions Nanocrystalline silver-derived solutions appear to have anti-inflammatory/pro-healing activity, particularly with a starting pH of 9. Solutions generated differently may have varying concentrations of different silver species, only some of which are anti-inflammatory. Nanocrystalline silver-derived solutions show promise for a variety of anti-inflammatory treatment applications. PMID:20170497
Rumpagaporn, Pinthip; Kaur, Amandeep; Campanella, Osvaldo H; Patterson, John A; Hamaker, Bruce R
2012-01-01
In in vitro batch fermentations, both alkali-extractable corn arabinoxylan (CAX) and its xylanase-hydrolyzate (CH) were utilized by human fecal microbiota and produced similar short chain fatty acid (SCFA) contents and desirable long fermentation profiles with low initial gas production. Fortification of these arabinoxylans into processed foods would contribute desirable dietary fiber benefits to humans. Heat and pH stability, as well as viscosity behavior of CAX and CH were investigated. Size exclusion chromatography was used to analyze the molecular size distribution after treatment at different pH's and heating temperatures for different time periods. Treated under boiling and pressure cooking conditions at pH 3, CAX was degraded to a smaller molecular size, whereas the molecular size of the CH showed only a minor decrease. CAX and CH were mostly stable at neutral pH, except when CAX was treated under pressure for 60 min that slightly lowered molecular size. At 37 °C, neither CAX nor CH was adversely affected by treatment at low or neutral pH. The viscosities of solutions containing 5% and 10% of CAX were 48.7 and 637.0 mPa.s, respectively that were higher than those of solutions containing 5% and 10% of its hydrolyzate at shear rate 1 s⁻¹. The CAX solutions showed Newtonian flow behavior, whereas shear-thinning behavior was observed in CH solutions. In conclusion, the hydrolyzate of CAX has potential to be used in high fiber drinks due to its favorable fermentation properties, higher pH and heat stability, lower and shear-thinning viscosity, and lighter color than the native CAX. Arabinoxylan extracted by an alkali from corn bran is a soluble fiber with a desirable low initial and extended fermentation property. Corn arabinoxylan hydrolyzate using an endoxylanase was much more stable at different levels of acidity and heat than the native arabinoxylan, and showed lower solution viscosity and shear-thinning property that indicates its potential as an alternative functional dietary fiber for the beverage industry. © 2011 Institute of Food Technologists®
Removal of oxytetracycline from aqueous solutions by hydroxyapatite as a low-cost adsorbent
NASA Astrophysics Data System (ADS)
Harja, Maria; Ciobanu, Gabriela
2017-11-01
The present paper involved a study of the adsorption process of the oxytetracycline drug from aqueous medium by using the hydroxyapatite nanopowders as adsorbent materials. The batch adsorption experiments were performed by monitoring the solution pH, contact time, adsorbent dosage and drug solution concentration. At pH 8 and ambient temperature, high oxytetracycline removal rates of about 97.58% and 89.95% for the uncalcined and calcined nanohydroxyapatites, respectively, were obtained. The kinetic studies indicate that the oxytetracycline adsorption onto nanohydroxyapatite samples follows a pseudo-second order kinetic model. The maximum adsorption capacities of 291.32 mg/g and 278.27 mg/g for uncalcined and calcined nanohydroxyapatite samples, respectively, have been found. So, the conclusion can be drawn that the hydroxyapatite shows good adsorption ability towards oxytetracycline.
Chen, Gunng-Shinng; Lee, Shiao-Pieng; Huang, Shu-Fu; Chao, Shih-Chi; Chang, Chung-Yi; Wu, Gwo-Jang; Li, Chung-Hsing; Loh, Shih-Hurng
2018-06-01
Homeostasis of intracellular pH (pH i ) plays vital roles in many cell functions, such as proliferation, apoptosis, differentiation and metastasis. Thus far, Na + -H + exchanger (NHE), Na + -HCO 3 - co-transporter (NBC), Cl - /HCO 3 - exchanger (AE) and Cl - /OH - exchanger (CHE) have been identified to co-regulate pH i homeostasis. However, functional and biological pH i -regulators in human dental pulp stem cells (hDPSCs) have yet to be identified. Microspectrofluorimetry technique with pH-sensitive fluorescent dye, BCECF, was used to detect pH i changes. NH 4 Cl and Na + -acetate pre-pulse were used to induce intracellular acidosis and alkalosis, respectively. Isoforms of pH i -regulators were detected by Western blot technique. The resting pH i was no significant difference between that in HEPES-buffered (nominal HCO 3 - -free) solution or CO 2 /HCO 3 -buffered system (7.42 and 7.46, respectively). The pH i recovery following the induced-intracellular acidosis was blocked completely by removing [Na + ] o , while only slowed (-63%) by adding HOE694 (a NHE1 specific inhibitor) in HEPES-buffered solution. The pH i recovery was inhibited entirely by removing [Na + ] o , while adding HOE 694 pulse DIDS (an anion-transporter inhibitor) only slowed (-55%) the acid extrusion. Both in HEPES-buffered and CO 2 /HCO 3 -buffered system solution, the pH i recovery after induced-intracellular alkalosis was entirely blocked by removing [Cl - ] o . Western blot analysis showed the isoforms of pH i regulators, including NHE1/2, NBCe1/n1, AE1/2/3/4 and CHE in the hDPSCs. We demonstrate for the first time that resting pH i is significantly higher than 7.2 and meditates functionally by two Na + -dependent acid extruders (NHE and NBC), two Cl - -dependent acid loaders (CHE and AE) and one Na + -independent acid extruder(s) in hDPSCs. These findings provide novel insight for basic and clinical treatment of dentistry. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Landau, U.
1984-01-01
The finite difference computation method was investigated for solving problems of interaction between a shock wave and a laminar boundary layer, through solution of the complete Navier-Stokes equations. This method provided excellent solutions, was simple to perform and needed a relatively short solution time. A large number of runs for various flow conditions could be carried out from which the interaction characteristics and principal factors that influence interaction could be studied.
Przybyt, Małgorzata; Miller, Ewa; Szreder, Tomasz
2011-04-04
The thermostability of glucose oxidase entrapped in silica gel obtained by sol-gel method was studied by thermostimulated fluorescence of FAD at pH 5 and 7 and compared with that of the native enzyme in the solution and at the presence of ethanol. The unfolding temperatures were found to be lower for the enzyme immobilised in gel as compared with the native enzyme but higher as for the enzyme at the presence of ethanol. In gel, the thermal denaturation of glucose oxidase is independent on pH while in solution the enzyme is more stable at pH 5. The investigation the enzyme in different environment by steady-state fluorescence of FAD and tryptophan, synchronous fluorescence and time-resolved fluorescence of tryptophan indicates that the state of the molecule (tertiary structure and molecular dynamics) is different in gel and in solution. The ethanol produced during gel precursor hydrolysis is not the main factor influencing the thermostability of the enzyme but more important are interactions of the protein with the gel lattice. Copyright © 2011 Elsevier B.V. All rights reserved.
Biosorption of copper, nickel and manganese using non-living biomass of marine alga, Ulva lactuca.
Omar, Hanan Hafez
2008-04-01
The adsorption of Cu2+, Ni2+ and Mn2+ onto the marine algal biomass of Ulva lactuca was investigated in single and multimetal solutions. This study was intended to determine the role of different pH values (2-8) on the biosorption of metals at different concentrations (10, 20 and 30 mg L(-1)). The biosorption capacity of Cu2+, Ni2+ and Mn2+ for 10 mg L(-1) was the same as 20 and 30 mg L(-1), increase with increasing pH up to pH 5.0 and then decreased, in single and multimetal solutions. The optimum pH value was observed in the pH range 4-5 for Cu2+ and pH 5-6 for Ni2+ and Mn2+. The maximum biosorption capacities of tested alga for Cu2+, Ni2+ and Mn2+ were 92, 80 and 75%, respectively in single metal solution at 10 mg L(-1) and pH 5.0. At a further increase of pH (8.0) the biosorption process for Cu2+, Ni2+ and Mn2+ (75, 69 and 63%, respectively at 10 mg L(-1)) was decreased. The minimum biosorptions were 60, 49 and 44% for Cu2+, Ni2+ and Mn2+, respectively in single metal solution at 10 mg L(-1) and pH 2.0. In the multimetal solution, algal biomass exhibited the maximum and the minimum biosorption capacity at different pH values the same as in single metal solution. The inhibitory role of other ions on sorption process can be well observed in multimetal mixture, where biosorption capacity of Cu2+, Ni2+ and Mn2+ were significantly decreased in the multimetal solutions. The maximum biosorption was recorded for Cu2+ (83%) in solution of Cu2+ + Mn2+, Mn2+ (67%) in solution of Ni2 + Mn2+ and for Ni2+ (74%) in solution of Ni2+ + Mn2+ at the concentration 10 mg L(-1) and pH 5.0. The observed reduction in the biosorption of Cu2+, Ni2+ and Mn2+ (65, 57 and 52%, respectively at 10 mg L(-1) and pH 5.0) was more pronounced in the multimetal solution of Cu2 + Ni2+ + Mn2+ as compared with single metal solution. The results demonstrated that the affinity of the tested alga for sorption of the investigated metal ions in single and multimetal solutions runs in the order Cu2+ > Ni2+ > Mn2+. Biosorption equilibrium was established by the Langmuir and Freundlich isotherm models. According to the analyses conducted, the biosorption of Cu2+, Ni2+ and Mn2+ to Ulva lactuca was more consistent with Freundlich isotherm.
NASA Astrophysics Data System (ADS)
Coşkun, M. İbrahim; Karahan, İsmail H.; Yücel, Yasin; Golden, Teresa D.
2016-04-01
CoCrMo bio-metallic alloys were coated with a hydroxyapatite (HA) film by electrodeposition using various electrochemical parameters. Response surface methodology and central composite design were used to optimize deposition parameters such as electrolyte pH, deposition potential, and deposition time. The effects of the coating parameters were evaluated within the limits of solution pH (3.66 to 5.34), deposition potential (-1.13 to -1.97 V), and deposition time (6.36 to 73.64 minutes). A 5-level-3-factor experimental plan was used to determine ideal deposition parameters. Optimum conditions for the deposition parameters of the HA coating with high in vitro corrosion performance were determined as electrolyte pH of 5.00, deposition potential of -1.8 V, and deposition time of 20 minutes.
Development of a pH sensing membrane electrode based on a new calix[4]arene derivative.
Kormalı Ertürün, H Elif; Demirel Özel, Ayça; Sayın, Serkan; Yılmaz, Mustafa; Kılıç, Esma
2015-01-01
A new pH sensing poly(vinyl chloride) (PVC) membrane electrode was developed by using recently synthesized 5,17-bis(4-benzylpiperidine-1-yl)methyl-25,26,27,28-tetrahydroxy calix[4]arene as an ionophore. The effects of membrane composition, inner filling solution and conditioning solution on the potential response of the proposed pH sensing membrane electrode were investigated. An optimum membrane composition of 3% ionophore, 67% o-nitrophenyl octyl ether (o-NPOE) as plasticizer, 30% PVC was found. The electrode exhibited a near-Nernstian slope of 58.7±1.1 mV pH(-1) in the pH range 1.9-12.7 at 20±1 °C. It showed good selectivity for H(+) ions in the presence of some cations and anions and a longer lifetime of at least 12 months when compared with the other PVC membrane pH electrodes reported in the literature. Having a wide working pH range, it was not only applied as a potentiometric indicator electrode in various acid-base titrations, but also successfully employed in different real samples. It has good reproducibility and repeatability with a response time of 6-7s. Compared to traditional glass pH electrode, it exhibited excellent potentiometric response after being used in fluoride-containing media. Copyright © 2014 Elsevier B.V. All rights reserved.
Stretchable wireless system for sweat pH monitoring.
Dang, Wenting; Manjakkal, Libu; Navaraj, William Taube; Lorenzelli, Leandro; Vinciguerra, Vincenzo; Dahiya, Ravinder
2018-06-01
Sensor-laden wearable systems that are capable of providing continuous measurement of key physiological parameters coupled with data storage, drug delivery and feedback therapy have attracted huge interest. Here we report a stretchable wireless system for sweat pH monitoring, which is able to withstand up to 53% uniaxial strain and more than 500 cycles to 30% strain. The stretchability of the pH sensor patch is provided by a pair of serpentine-shaped stretchable interconnects. The pH sensing electrode is made of graphite-polyurethane composite, which is suitable for biosensor application. The sensing patch validated through in-depth electrochemical studies, exhibits a pH sensitivity of 11.13 ± 5.8 mV/pH with a maximum response time of 8 s. Interference study of ions and analyte (Na + , K + and glucose) in test solutions shows negligible influence on the pH sensor performance. The pH data can be wirelessly and continuously transmitted to smartphone through a stretchable radio-frequency-identification antenna, of which the radiating performance is stable under 20% strain, as proved by vector network analyzer measurement. To evaluate the full system, the pH value of a human sweat equivalent solution has been measured and wirelessly transmitted to a custom-developed smart phone App. Copyright © 2018 Elsevier B.V. All rights reserved.
The influence of pH on biotite dissolution and alteration kinetics at low temperature
Acker, James G.; Bricker, O.P.
1992-01-01
Biotite dissolution rates in acidic solutions were determined in fluidized-bed reactors and flowthrough columns. Biotite dissolution rates increased inversely as a linear function of pH in the pH range 3-7, where the rate order n = -0.34. Biotite dissolved incongruently over this pH range, with preferential release of magnesium and iron from the octahedral layer. Release of tetrahedral silicon was much greater at pH 3 than at higher pH. Iron release was significantly enhanced by low pH conditions. Solution compositions from a continuous exposure flow-through column of biotite indicated biotite dissolves incongruently at pH 4, consistent with alteration to a vermiculite-type product. Solution compositions from a second intermittent-flow column exhibited elevated cation release rates upon the initiation of each exposure to solution. The presence of strong oxidizing agents, the mineral surface area, and sample preparation methodology also influenced the dissolution or alteration kinetics of biotite. ?? 1992.
Application of principal component analysis for the optimisation of lead(II) biosorption.
Wajda, Łukasz; Duda-Chodak, Aleksandra; Tarko, Tomasz; Kamiński, Paweł
2017-10-03
Current study was focused on optimising lead(II) biosorption carried out by living cells of Arthrospira platensis using Principal Component Analysis. Various experimental conditions were considered: initial metal concentration (50 and 100 mg/l), solution pH (4.0, 4.5, 5.0, 5.5) and contact time (10, 20, 30, 40, 50 and 60 min) at constant rotary speed 200 rpm. It was found that when the biomass was separated from experimental solutions by the filtration, almost 50% of initial metal dose was removed by the filter paper. Moreover, pH was the most important parameter influencing examined processes. The Principal Component Analysis indicated that the most optimum conditions for lead(II) biosorption were metal initial concentration 100 mg/l, pH 4.5 and time 60 min. According to the analysis of the first component it might be stated that the lead(II) uptake increases in time. In overall, it was found to be useful for analysing data obtained in biosorption experiments and eliminating insignificant experimental conditions. Experimental data fitted Langmuir and Dubinin-Radushkevich models indicating that physical and chemical absorption take place at the same time. Further studies are necessary to verify how sorption-desorption cycles affect A. platensis cells.
Influence of soil solution cation composition on boron adsorption by soils
USDA-ARS?s Scientific Manuscript database
Boron (B) adsorption on five arid-zone soil samples from California was investigated as a function of solution pH (4-10) and cation composition (Na, Ca, or Mg). Boron adsorption increased with increasing solution pH, reached an adsorption maximum near pH 9, and decreased with further increases with...
Immobilization of chromate in hyperalkaline waste streams by green rusts and zero-valent iron.
Rogers, Christine M; Burke, Ian T; Ahmed, Imad A M; Shaw, Samuel
2014-01-01
Zero-valent iron (ZVI) and green rusts can be used as reductants to convert chromium from soluble, highly toxic Cr(VI) to insoluble Cr(III). This study compared the reduction rates of Cr(VI) by ZVI and two carbonate green rust phases in alkaline/hyperalkaline solutions. Batch experiments were carried out with synthetic chromate solutions at pH 7.7-12.3 and a chromite ore processing residue (COPR) leachate (pH approximately 12.2). Green rust removes chromate from high pH solutions (pH 10-12.5) very rapidly (<400 s). Chromate reduction rates for both green rust phases were consistently higher than for ZVI throughout the pH range studied; the surface area normalized rate constants were two orders of magnitude higher in the COPR leachate solution at pH 12.2. The performances of both green rusts were unaffected by changes in pH. In contrast, ZVI exhibited a marked decline in reduction rate with increasing pH to become almost ineffective above pH12.
Viswanathan, Tito
2014-07-29
A method of synthesizing carbon-magnetite nanocomposites. In one embodiment, the method includes the steps of (a) dissolving a first amount of an alkali salt of lignosulfonate in water to form a first solution, (b) heating the first solution to a first temperature, (c) adding a second amount of iron sulfate (FeSO.sub.4) to the first solution to form a second solution, (d) heating the second solution at a second temperature for a first duration of time effective to form a third solution of iron lignosulfonate, (e) adding a third amount of 1N sodium hydroxide (NaOH) to the third solution of iron lignosulfonate to form a fourth solution with a first pH level, (f) heating the fourth solution at a third temperature for a second duration of time to form a first sample, and (g) subjecting the first sample to a microwave radiation for a third duration of time effective to form a second sample containing a plurality of carbon-magnetite nanocomposites.
Shelf-Life of Chlorine Solutions Recommended in Ebola Virus Disease Response.
Iqbal, Qais; Lubeck-Schricker, Maya; Wells, Emma; Wolfe, Marlene K; Lantagne, Daniele
2016-01-01
In Ebola Virus Disease (EVD) outbreaks, it is widely recommended to wash living things (handwashing) with 0.05% (500 mg/L) chlorine solution and non-living things (surfaces, personal protective equipment, dead bodies) with 0.5% (5,000 mg/L) chlorine solution. Chlorine solutions used in EVD response are primarily made from powdered calcium hypochlorite (HTH), granular sodium dichloroisocyanurate (NaDCC), and liquid sodium hypochlorite (NaOCl), and have a pH range of 5-11. Chlorine solutions degrade following a reaction highly dependent on, and unusually sensitive to, pH, temperature, and concentration. We determined the shelf-life of 0.05% and 0.5% chlorine solutions used in EVD response, including HTH, NaDCC, stabilized NaOCl, generated NaOCl, and neutralized NaOCl solutions. Solutions were stored for 30 days at 25, 30, and 35°C, and tested daily for chlorine concentration and pH. Maximum shelf-life was defined as days until initial concentration fell to <90% of initial concentration in ideal laboratory conditions. At 25-35°C, neutralized-NaOCl solutions (pH = 7) had a maximum shelf-life of a few hours, NaDCC solutions (pH = 6) 2 days, generated NaOCl solutions (pH = 9) 6 days, and HTH and stabilized NaOCl solutions (pH 9-11) >30 days. Models were developed for solutions with maximum shelf-lives between 1-30 days. Extrapolating to 40°C, the maximum predicted shelf-life for 0.05% and 0.5% NaDCC solutions were 0.38 and 0.82 hours, respectively; predicted shelf-life for 0.05% and 0.5% generated NaOCl solutions were >30 and 5.4 days, respectively. Each chlorine solution type offers advantages and disadvantages to responders, as: NaDCC is an easy-to-import high-concentration effervescent powder; HTH is similar, but forms a precipitate that may clog pipes; and, NaOCl solutions can be made locally, but are difficult to transport. We recommend responders chose the most appropriate source chlorine compound for their use, and ensure solutions are stored at appropriate temperatures and used or replaced before expiring.
Abu-Thabit, Nedal; Umar, Yunusa; Ratemi, Elaref; Ahmad, Ayman; Ahmad Abuilaiwi, Faraj
2016-06-27
A new optical pH sensor based on polysulfone (PSU) and polyaniline (PANI) was developed. A transparent and flexible PSU membrane was employed as a support. The electrically conductive and pH-responsive PANI was deposited onto the membrane surface by in situ chemical oxidative polymerization (COP). The absorption spectra of the PANI-coated PSU membranes exhibited sensitivity to pH changes in the range of 4-12, which allowed for designing a dual wavelength pH optical sensor. The performance of the membranes was assessed by measuring their response starting from high pH and going down to low pH, and vice versa. It was found that it is necessary to precondition the sensor layers before each measurement due to the slight hysteresis observed during forward and backward pH titrations. PSU membranes with polyaniline coating thicknesses in the range of ≈100-200 nm exhibited fast response times of <4 s, which are attributed to the porous, rough and nanofibrillar morphology of the polyaniline coating. The fabricated pH sensor was characterized by a sigmoidal response (R² = 0.997) which allows for pH determination over a wide dynamic range. All membranes were stable for a period of more than six months when stored in 1 M HCl solution. The reproducibility of the fabricated optical pH sensors was found to be <0.02 absorption units after one month storage in 1 M HCl solution. The performance of the optical pH sensor was tested and the obtained pH values were compared with the results obtained using a pH meter device.
Abu-Thabit, Nedal; Umar, Yunusa; Ratemi, Elaref; Ahmad, Ayman; Ahmad Abuilaiwi, Faraj
2016-01-01
A new optical pH sensor based on polysulfone (PSU) and polyaniline (PANI) was developed. A transparent and flexible PSU membrane was employed as a support. The electrically conductive and pH-responsive PANI was deposited onto the membrane surface by in situ chemical oxidative polymerization (COP). The absorption spectra of the PANI-coated PSU membranes exhibited sensitivity to pH changes in the range of 4–12, which allowed for designing a dual wavelength pH optical sensor. The performance of the membranes was assessed by measuring their response starting from high pH and going down to low pH, and vice versa. It was found that it is necessary to precondition the sensor layers before each measurement due to the slight hysteresis observed during forward and backward pH titrations. PSU membranes with polyaniline coating thicknesses in the range of ≈100–200 nm exhibited fast response times of <4 s, which are attributed to the porous, rough and nanofibrillar morphology of the polyaniline coating. The fabricated pH sensor was characterized by a sigmoidal response (R2 = 0.997) which allows for pH determination over a wide dynamic range. All membranes were stable for a period of more than six months when stored in 1 M HCl solution. The reproducibility of the fabricated optical pH sensors was found to be <0.02 absorption units after one month storage in 1 M HCl solution. The performance of the optical pH sensor was tested and the obtained pH values were compared with the results obtained using a pH meter device. PMID:27355953
The Bacterial Endospore Stain on Schaeffer Fulton using Variation of Methylene Blue Solution
NASA Astrophysics Data System (ADS)
Oktari, A.; Supriatin, Y.; Kamal, M.; Syafrullah, H.
2017-02-01
Endospores staining is the type of staining to recognize the presence spore in bacterial vegetative cells. The bacterial endospores need a staining which can penetrate wall thickness of spore bacteria. A method of endospores staining is Schaeffer Fulton method that used Malachite Green. It is an alkaline substance staining that can staining the spore bacteria. In this research, it have found the alternative staining that can replace Malachite Green solution in spore bacterial stain. The alternative staining used is Methylene Blue solution (0,5 %, 0,7%, and 1% concentration) with pH variation (10, 11, and 12), and varyous heating time (3, 4, and 5 minutes). The all treatments staining have been effect on bacterial spores staining results. The warming time greatly affect the dye to penetrate the walls of bacterial spores, this can be seen in the results with various concentration at pH 10, indicates that the not long warm-up time 3 and 4 minutes, bacterial spores are not stained, while in the longer heating time is 5 minutes bacterial spores stained. This is caused because the longer heating time can make the pores of spore wall is open so that can facilitate the dye to get into the bacterial spores.
Electrocoagulation and decolorization of landfill leachate
NASA Astrophysics Data System (ADS)
Mussa, Zainab Haider; Othman, Mohamed Rozali; Abdullah, Md Pauzi
2013-11-01
In this study, several operating conditions such as electrode material, treatment time, applied voltage, Cl□ concentration and PH of solution were tested on treatability of landfill leachate by using electrocoagulation (EC) method. According to the results, EC method can be used efficiently for the treatment of landfill leachate by using proper operating conditions. The best removal rats were obtained when C (rod) electrode as anode, operating time is 120 min, voltage applied is 10 V, NaCl concentration is 5.85 g/L and the raw PH, for these conditions, 70% color removal was obtained.
Machado, Fernando M; Bergmann, Carlos P; Fernandes, Thais H M; Lima, Eder C; Royer, Betina; Calvete, Tatiana; Fagan, Solange B
2011-09-15
Multi-walled carbon nanotubes and powdered activated carbon were used as adsorbents for the successful removal of Reactive Red M-2BE textile dye from aqueous solutions. The adsorbents were characterised by infrared spectroscopy, N(2) adsorption/desorption isotherms and scanning electron microscopy. The effects of pH, shaking time and temperature on adsorption capacity were studied. In the acidic pH region (pH 2.0), the adsorption of the dye was favourable using both adsorbents. The contact time to obtain equilibrium at 298K was fixed at 1h for both adsorbents. The activation energy of the adsorption process was evaluated from 298 to 323K for both adsorbents. The Avrami fractional-order kinetic model provided the best fit to the experimental data compared with pseudo-first-order or pseudo-second-order kinetic adsorption models. For Reactive Red M-2BE dye, the equilibrium data were best fitted to the Liu isotherm model. Simulated dyehouse effluents were used to check the applicability of the proposed adsorbents for effluent treatment. Copyright © 2011 Elsevier B.V. All rights reserved.
Foley, Nicholas A; Lail, Marty; Lee, John P; Gunnoe, T Brent; Cundari, Thomas R; Petersen, Jeffrey L
2007-05-30
Complexes of the type TpRu(L)(NCMe)R [L = CO or PMe3; R = Ph or Me; Tp = hydridotris(pyrazolyl)borate] initiate C-H activation of benzene. Kinetic studies, isotopic labeling, and other experimental evidence suggest that the mechanism of benzene C-H activation involves reversible dissociation of acetonitrile, reversible benzene coordination, and rate-determining C-H activation of coordinated benzene. TpRu(PMe3)(NCMe)Ph initiates C-D activation of C6D6 at rates that are approximately 2-3 times more rapid than that for TpRu(CO)(NCMe)Ph (depending on substrate concentration); however, the catalytic hydrophenylation of ethylene using TpRu(PMe3)(NCMe)Ph is substantially less efficient than catalysis with TpRu(CO)(NCMe)Ph. For TpRu(PMe3)(NCMe)Ph, C-H activation of ethylene, to ultimately produce TpRu(PMe3)(eta3-C4H7), is found to kinetically compete with catalytic ethylene hydrophenylation. In THF solutions containing ethylene, TpRu(PMe3)(NCMe)Ph and TpRu(CO)(NCMe)Ph separately convert to TpRu(L)(eta3-C4H7) (L = PMe3 or CO, respectively) via initial Ru-mediated ethylene C-H activation. Heating mesitylene solutions of TpRu(L)(eta3-C4H7) under ethylene pressure results in the catalytic production of butenes (i.e., ethylene hydrovinylation) and hexenes.
Adsorption of Cd(II) Metal Ion on Adsorbent beads from Biomass Saccharomycess cereviceae - Chitosan
NASA Astrophysics Data System (ADS)
Hasri; Mudasir
2018-01-01
The adsorbent beads that was preparation from Saccharomycess cereviceae culture strain FN CC 3012 and shrimp shells waste and its application for adsorption of Cd (II) metal ion has been studied. The study start with combination of Saccharomycess cereviceae biomass to chitosan (Sc-Chi), contact time, pH of solution and initial concentration of cations. Total Cd(II) metal ion adsorbed was calculated from the difference of metal ion concentration before and after adsorption by AAS. The results showed that optimum condition for adsorption of Cd(II) ions by Sc-Chi beads was achieved with solution pH of 4, contact time of 60 minutes and initial concentration adsorption 100mg/L. The hydroxyl (-OH) and amino (-NH2) functional groups were believed to be responsible for the adsorption of Cd(II) ions.
Stabilizing sodium hypochlorite at high pH: effects on soft tissue and dentin.
Jungbluth, Holger; Marending, Monika; De-Deus, Gustavo; Sener, Beatrice; Zehnder, Matthias
2011-05-01
When sodium hypochlorite solutions react with tissue, their pH drops and tissue sorption decreases. We studied whether stabilizing a NaOCl solution at a high pH would increase its soft-tissue dissolution capacity and effects on the dentin matrix compared with a standard NaOCl solution of the same concentration and similar initial pH. NaOCl solutions were prepared by mixing (1:1) a 10% stock solution with water (standard) or 2 mol/L NaOH (stabilized). Physiological saline and 1 mol/L NaOH served as the controls. Chlorine content and alkaline capacity of NaOCl solutions were determined. Standardized porcine palatal soft-tissue specimens and human root dentin bars were exposed to test and control solutions. Weight loss percentage was assessed in the soft-tissue dissolution assay. Three-point bending tests were performed on the root dentin bars to determine the modulus of elasticity and flexural strength. Values between groups were compared using one-way analysis of variance with the Bonferroni correction for multiple testing (α < .05). Both solutions contained 5% NaOCl. One milliliter of the standard and the stabilized solution consumed 4.0 mL and 13.7 mL of a 0.1-mol/L HCl solution before they reached a pH level of 7.5, respectively. The stabilized NaOCl dissolved significantly more soft tissue than the standard solution, and the pH remained high. It also caused a higher loss in elastic modulus and flexure strength (P < .05) than the control solutions, whereas the standard solution did not. NaOH-stabilized NaOCl solutions have a higher alkaline capacity and are thus more proteolytic than standard counterparts. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Katre, Uma V; Mazumder, Suman; Prusti, Rabi K; Mohanty, Smita
2009-11-13
In moths, pheromone-binding proteins (PBPs) are responsible for the transport of the hydrophobic pheromones to the membrane-bound receptors across the aqueous sensillar lymph. We report here that recombinant Antheraea polyphemus PBP1 (ApolPBP1) picks up hydrophobic molecule(s) endogenous to the Escherichia coli expression host that keeps the protein in the "open" (bound) conformation at high pH but switches to the "closed" (free) conformation at low pH. This finding has bearing on the solution structures of undelipidated lepidopteran moth PBPs determined thus far. Picking up a hydrophobic molecule from the host expression system could be a common feature for lipid-binding proteins. Thus, delipidation is critical for bacterially expressed lipid-binding proteins. We have shown for the first time that the delipidated ApolPBP1 exists primarily in the closed form at all pH levels. Thus, current views on the pH-induced conformational switch of PBPs hold true only for the ligand-bound open conformation of the protein. Binding of various ligands to delipidated ApolPBP1 studied by solution NMR revealed that the protein in the closed conformation switches to the open conformation only at or above pH 6.0 with a protein to ligand stoichiometry of approximately 1:1. Mutation of His(70) and His(95) to alanine drives the equilibrium toward the open conformation even at low pH for the ligand-bound protein by eliminating the histidine-dependent pH-induced conformational switch. Thus, the delipidated double mutant can bind ligand even at low pH in contrast to the wild type protein as revealed by fluorescence competitive displacement assay using 1-aminoanthracene and solution NMR.
NASA Astrophysics Data System (ADS)
Reddy, T. Ranjeth Kumar; Kim, Hyun-Joong
2016-07-01
In recent years, there has been significant interest in the development of novel metallic nanoparticles using various top-down and bottom-up synthesis techniques. Kenaf is a huge biomass product and a potential component for industrial applications. In this work, we investigated the green synthesis of silver nanoparticles (AgNPs) by using kenaf ( Hibiscus cannabinus) cellulose extract and sucrose, which act as stabilizing and reducing agents in solution. With this method, by changing the pH of the solution as a function of time, we studied the optical, morphological and antibacterial properties of the synthesized AgNPs. In addition, these nanoparticles were characterized by Ultraviolet-visible spectroscopy, transmission electron microscopy (TEM), field-emission scanning electron microscopy, Fourier transform infrared (FTIR) spectroscopy and energy-dispersive X-ray spectroscopy (EDX). As the pH of the solution varies, the surface plasmon resonance peak also varies. A fast rate of reaction at pH 10 compared with that at pH 5 was identified. TEM micrographs confirm that the shapes of the particles are spherical and polygonal. Furthermore, the average size of the nanoparticles synthesized at pH 5, pH 8 and pH 10 is 40.26, 28.57 and 24.57 nm, respectively. The structure of the synthesized AgNPs was identified as face-centered cubic (fcc) by XRD. The compositional analysis was determined by EDX. FTIR confirms that the kenaf cellulose extract and sucrose act as stabilizing and reducing agents for the silver nanoparticles. Meanwhile, these AgNPs exhibited size-dependent antibacterial activity against Escherichia coli ( E. coli) and two other unknown bacteria from mobile phone screens and computer keyboard surfaces.
Spatial and temporal patterns of xylem sap pH derived from stems and twigs of Populus deltoides L.
Doug Aubrey; Justin Boyles; Laura Krysinsky; Robert Teskey
2011-01-01
Xylem sap pH (pHX) is critical in determining the quantity of inorganic carbon dissolved in xylem solution from gaseous [CO2] measurements. Studies of internal carbon transport have generally assumed that pHX derived from stems and twigs is similar and that pHX remains constant through time; however, no empirical studies have investigated these assumptions. If any of...
Grafting of GMA and some comonomers onto chitosan for controlled release of diclofenac sodium.
Sharma, Rajeev Kr; Lalita; Singh, Anirudh P; Chauhan, Ghanshyam S
2014-03-01
In order to develop pH sensitive hydrogels for controlled drug release we have graft copolymerized glycidyl methacrylate (GMA) with comonomers acrylic acid, acrylamide and acrylonitrile, onto chitosan (Ch) by using potassium persulphate (KPS) as free radical initiator in aqueous solution. The optimum percent grafting for GMA was recorded for 1g chitosan at [KPS]=25.00 × 10(-3)mol/L, [GMA]=0.756 × 10(-3)mol/L, reaction temperature=60 °C and reaction time=1h in 20 mL H2O. Binary monomers were grafted for five different concentrations at optimum grafting conditions evaluated for GMA alone onto chitosan. The graft copolymers were characterized by FTIR, XRD, TGA and SEM. The swelling properties of chitosan and graft copolymers were investigated at different pH to define their end uses in sustained release of an anti-inflammatory drug, diclofenac sodium. Percent drug release w.r.t. drug loaded in polymeric sample was studied as function of time in buffer solutions of pH 2.0 and 7.4. In vitro release data was analyzed using Fick's Law. Chitosan grafted with binary monomers, GMA-co-AAm and GMA-co-AN showed very good results for sustained release of drug at 7.4 pH. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Zhigang; Liu, Zhifeng; Wu, Zhibin; Zeng, Guangming; Shao, Binbin; Liu, Yujie; Jiang, Yilin; Zhong, Hua; Liu, Yang
2018-05-01
A novel graphene-based material of tea saponin functionalized reduced graphene oxide (TS-RGO) was synthesized via a facil thermal method, and it was characterized as the absorbent for Cd(II) removal from aqueous solutions. The factors on adsorption process including solution pH, contact time, initial concentration of Cd(II) and background electrolyte cations were studied to optimize the conditions for maximum adsorption at room temperature. The results indicated that Cd(II) adsorption was strongly dependent on pH and could be strongly affected by background electrolytes and ionic strength. The optimal pH and required equilibrium time was 6.0 and 10 min, respectively. The Cd(II) removal decreased with the presence of background electrolyte cations (Na+ < Ca2+ < Al3+). The adsorption kinetics of Cd(II) followed well with the pseudo-second-order model. The adsorption isotherm fitted well to the Langmuir model, indicating that the adsorption was a monolayer adsorption process occurred on the homogeneous surfaces of TS-RGO. The maximum monolayer adsorption capacity was 127 mg/g at 313 K and pH 6.0. Therefore, the TS-RGO was considered to be a cost-effective and promising material for the removal of Cd(II) from wastewater.
Effects of pH and elevated glucose levels on the electrochemical behavior of dental implants.
Tamam, Evsen; Turkyilmaz, Ilser
2014-04-01
Implant failure is more likely to occur in persons with medically compromising systemic conditions, such as diabetes related to high blood glucose levels and inflammatory diseases related to pH levels lower than those in healthy people. The aim of this study was to investigate the effects of lower pH level and simulated- hyperglycemia on implant corrosion as these effects are critical to biocompatibility and osseointegration. The electrochemical corrosion properties of titanium implants were studied in four different solutions: Ringer's physiological solution at pH = 7.0 and pH = 5.5 and Ringer's physiological solution containing 15 mM dextrose at pH = 7 and pH = 5.5. Corrosion behaviors of dental implants were determined by cyclic polarization test and electrochemical impedance spectroscopy. Surface alterations were studied using a scanning electron microscope. All test electrolytes led to apparent differences in corrosion behavior of the implants. The implants under conditions of test exhibited statistically significant increases in I(corr) from 0.2372 to 1.007 μAcm(-2), corrosion rates from 1.904 to 8.085 mpy, and a decrease in polarization resistances from 304 to 74 Ω. Implants in dextrose-containing solutions were more prone to corrosion than those in Ringer's solutions alone. Increasing the acidity also yielded greater corrosion rates for the dextrose-containing solutions and the solutions without dextrose.
2015-01-01
The translocation (T) domain of diphtheria toxin plays a critical role in moving the catalytic domain across the endosomal membrane. Translocation/insertion is triggered by a decrease in pH in the endosome where conformational changes of T domain occur through several kinetic intermediates to yield a final trans-membrane form. High-resolution structural studies are only applicable to the static T-domain structure at physiological pH, and studies of the T-domain translocation pathway are hindered by the simultaneous presence of multiple conformations. Here, we report the application of hydrogen–deuterium exchange mass spectrometry (HDX-MS) for the study of the pH-dependent conformational changes of the T domain in solution. Effects of pH on intrinsic HDX rates were deconvolved by converting the on-exchange times at low pH into times under our “standard condition” (pH 7.5). pH-Dependent HDX kinetic analysis of T domain clearly reveals the conformational transition from the native state (W-state) to a membrane-competent state (W+-state). The initial transition occurs at pH 6 and includes the destabilization of N-terminal helices accompanied by the separation between N- and C-terminal segments. The structural rearrangements accompanying the formation of the membrane-competent state expose a hydrophobic hairpin (TH8–9) to solvent, prepare it to insert into the membrane. At pH 5.5, the transition is complete, and the protein further unfolds, resulting in the exposure of its C-terminal hydrophobic TH8–9, leading to subsequent aggregation in the absence of membranes. This solution-based study complements high resolution crystal structures and provides a detailed understanding of the pH-dependent structural rearrangement and acid-induced oligomerization of T domain. PMID:25290210
Li, Jing; Rodnin, Mykola V; Ladokhin, Alexey S; Gross, Michael L
2014-11-04
The translocation (T) domain of diphtheria toxin plays a critical role in moving the catalytic domain across the endosomal membrane. Translocation/insertion is triggered by a decrease in pH in the endosome where conformational changes of T domain occur through several kinetic intermediates to yield a final trans-membrane form. High-resolution structural studies are only applicable to the static T-domain structure at physiological pH, and studies of the T-domain translocation pathway are hindered by the simultaneous presence of multiple conformations. Here, we report the application of hydrogen-deuterium exchange mass spectrometry (HDX-MS) for the study of the pH-dependent conformational changes of the T domain in solution. Effects of pH on intrinsic HDX rates were deconvolved by converting the on-exchange times at low pH into times under our "standard condition" (pH 7.5). pH-Dependent HDX kinetic analysis of T domain clearly reveals the conformational transition from the native state (W-state) to a membrane-competent state (W(+)-state). The initial transition occurs at pH 6 and includes the destabilization of N-terminal helices accompanied by the separation between N- and C-terminal segments. The structural rearrangements accompanying the formation of the membrane-competent state expose a hydrophobic hairpin (TH8-9) to solvent, prepare it to insert into the membrane. At pH 5.5, the transition is complete, and the protein further unfolds, resulting in the exposure of its C-terminal hydrophobic TH8-9, leading to subsequent aggregation in the absence of membranes. This solution-based study complements high resolution crystal structures and provides a detailed understanding of the pH-dependent structural rearrangement and acid-induced oligomerization of T domain.
Garbacz, Grzegorz; Kołodziej, Bartosz; Koziolek, Mirko; Weitschies, Werner; Klein, Sandra
2014-01-23
The hydrogen carbonate buffer is considered as the most biorelevant buffer system for the simulation of intestinal conditions and covers the physiological pH range of the luminal fluids from pH 5.5 to about pH 8.4. The pH value of a hydrogen carbonate buffer is the result of a complex and dynamic interplay of the concentration of hydrogen carbonate ions, carbonic acid, the concentration of dissolved and solvated carbon dioxide and its partial pressure above the solution. The complex equilibrium between the different ions results in a thermodynamic instability of hydrogen carbonate solutions. In order to use hydrogen carbonate buffers with pH gradients in the physiological range and with the dynamics observed in vivo without changing the ionic strength of the solution, we developed a device (pHysio-grad®) that provides both acidification of the dissolution medium by microcomputer controlled carbon dioxide influx and alkalisation by degassing. This enables a continuous pH control and adjustment during dissolution of ionisable compounds. The results of the pH adjustment indicate that the system can compensate even rapid pH changes after addition of a basic or acidic moiety in amounts corresponding up to 90% of the overall buffer capacity. The results of the dissolution tests performed for a model formulation containing ionizable compounds (Nexium 20mg mups) indicate that both the simulated fasting intraluminal pH-profiles and the buffer species can significantly affect the dissolution process by changing the lag time prior to initial drug release and the release rate of the model compound. A prediction of the in vivo release behaviour of this formulation is thus most likely strongly related to the test conditions such as pH and buffer species. Copyright © 2013 Elsevier B.V. All rights reserved.
Culler, M D; Saricay, Y; Harte, F M
2017-06-01
Solutions of 10 commonly used emulsifying salts (ES) listed in the Code of Federal Regulations (21CFR133.179) for pasteurized process cheese were tested for their effect on the turbidity of a diluted milk system at different pH and protein concentrations to characterize the conditions that affect micellar structure. Emulsifying salt solutions were made by mixing the ES in a 1-in-20 dilution of water in skim milk ultrafiltrate (3 kDa molecular weight cut-off) to obtain ES concentrations from 0 to 248 mM. Skim milk was added to solutions containing nanopure water, skim milk ultrafiltrate, and a specific ES ranging in concentration from 0 to 248 mM and pH 5, 5.8, 6.8, 7.8, and 8.8. The turbidity of the samples was measured as the optical density at 400 nm immediately after mixing (time, t = 0), after 30 s (t = 30s), and after 30 min (t = 30min). Emulsifying salts were found to cause a decrease in the turbidity of the system, which was modeled using an exponential decay model, where C* represents a threshold salt concentration at which rapid dissociation occurs. At pH values 5.8 and 6.8, the ES caused the greatest decrease in turbidity of the diluted milk system. At pH 5, the ES had the least effect on the turbidity of the system. Sodium hexametaphosphate was found to have the strongest dissociative effect, with a C* value of 0.33 mM for t = 0 at pH 6.8. In contrast, the largest C* value calculated at pH 6.8 was monosodium phosphate at 278.22 mM. Increased time resulted in lower C* values. The model established for this study can be used to predict the dissociation of casein micelles in the presence of various types of ES. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Removal of acid blue 062 on aqueous solution using calcinated colemanite ore waste.
Atar, Necip; Olgun, Asim
2007-07-19
Colemanite ore waste (CW) has been employed as adsorbent for the removal of acid blue 062 anionic dye (AB 062) from aqueous solution. The adsorption of AB 062 onto CW was examined with respect to contact time, calcination temperature, particle size, pH, adsorbent dosage and temperature. The physical and chemical properties of the CW, such as particle sizes and calcinations temperature, play important roles in dye adsorption. The dye adsorption largely depends on the initial pH of the solution with maximum uptake occurring at pH 1. Three simplified kinetics models, namely, pseudo-first order, pseudo-second order, and intraparticle diffusion models were tested to investigate the adsorption mechanisms. The kinetic adsorption of AB 062 on CW follows a pseudo-second order equation. The adsorption data have been analyzed using Langmuir and Freundlich isotherms. The results indicate that the Langmuir model provides the best correlation of the experimental data. Isotherms have also been used to obtain the thermodynamic parameters such as free energy, enthalpy and entropy of the adsorption of dye onto CW.
Sol-gel method for encapsulating molecules
Brinker, C. Jeffrey; Ashley, Carol S.; Bhatia, Rimple; Singh, Anup K.
2002-01-01
A method for encapsulating organic molecules, and in particular, biomolecules using sol-gel chemistry. A silica sol is prepared from an aqueous alkali metal silicate solution, such as a mixture of silicon dioxide and sodium or potassium oxide in water. The pH is adjusted to a suitably low value to stabilize the sol by minimizing the rate of siloxane condensation, thereby allowing storage stability of the sol prior to gelation. The organic molecules, generally in solution, is then added with the organic molecules being encapsulated in the sol matrix. After aging, either a thin film can be prepared or a gel can be formed with the encapsulated molecules. Depending upon the acid used, pH, and other processing conditions, the gelation time can be from one minute up to several days. In the method of the present invention, no alcohols are generated as by-products during the sol-gel and encapsulation steps. The organic molecules can be added at any desired pH value, where the pH value is generally chosen to achieve the desired reactivity of the organic molecules. The method of the present invention thereby presents a sufficiently mild encapsulation method to retain a significant portion of the activity of the biomolecules, compared with the activity of the biomolecules in free solution.
NASA Astrophysics Data System (ADS)
King, P. L.; De Deckker, P.
2012-12-01
On Mars, limited solutions (water/brine) were likely present episodically. Gradients in solution abundance may have caused salt precipitation and re-solution, brine reflux, pH gradients, and cycling of anions and cations; we provide an example of such processes in a playa lake. We propose that on Mars, the limited, episodic solutions, pH and abundant Fe-O(-H) phases are significant factors in salt precipitation and in promoting adsorption/desorption of anions and cations. FACTORS LEADING TO EPISODIC SOLUTIONS: Episodic movement of solutions may be driven by punctuated processes that 1) remove surface materials (e.g., impact and sedimentary mass wasting and deflation); 2) add surface materials (e.g., impact, volcanic and sedimentary processes); and 3) increase temperature and/or decrease atmospheric pressure (e.g., seasons, diurnal cycles, variation in obliquity). Removal and addition of surface materials results in topographic gradients that change pressure gradients of any potential groundwater, films, or buried ground ice. For example, episodic fluid flow and salt precipitation/re-solution may occur at topographic discontinuities like craters/basins, channel walls, mounds and dunes. Such areas provide the opportunity to sample multiple fluid sources (with different pH, Eh and total dissolved solids, TDS) and they may be the foci of subsurface solution flow and surface transport. EARTH ANALOG: Interplay of the three processes above is seen in Lake Tyrrell (playa), western Victoria, Australia (McCumber, P, 1991 http://vro.dpi.vic.gov.au). During wetter periods, springs from the regional groundwater (low pH, oxidized, mod-high TDS) mix with lake waters and saline 'reflux' brines (mod. pH, reduced, high TDS) at the lake edge at the base of higher ground. The Br/Cl of the reflux brines indicates mineral re-solution. Gypsum and Fe-O(-H) phases precipitate near the lake edge. During hot, dry climate episodes the lake precipitates gypsum and carbonate, efflorescent salts are common, and these salts may form eolian dunes with fine particles. We may expect similar processes and mineral and chemical gradients in craters/basins on Mars like Gale Crater, the site of the Mars Science Laboratory mission. ROLE OF Fe-O(-H) PHASES: Nanophase Fe-O(-H)-phases are abundant on Mars and their precipitation results in an Fe-poor solution and salts (like Lake Tyrrell). Fe-O(-H) phases precipitate most readily at near-neutral pH; however, the high Fe of Mars' surface allows for pH>1. Nanophase Fe-O(-H)-phases have surface species that promote adsorption; which may be important in dry conditions like Mars. If we take goethite (FeO(OH)), the surface species and aqueous ions in solution are Fe3+ (pH<~2); Fe(OH)2+ (pH~2-3.5); Fe(OH)2+ (pH~3.5-~8); and FeOH4- (pH>~8). Other Fe-O(-H) phases have slightly different pH limits. Thus, at pH<~8, Fe-O(-H) surfaces sequester anions in surface complexes or in Fe-bearing salts (e.g. Fe3+-phosphate and sulfates, especially at pH<4). PO43- species have high adsorption affinity, followed by SO42-, Cl-(O) and Br-(O) species. At pH>~8, adsorption and exchange of cations are likely. These chemical variations may provide us with clues of the past pH on Mars.
A Methodology for Characterizing Potential Uranium Transport in Deep Geological Disposal Sites
NASA Astrophysics Data System (ADS)
Dittrich, T. M.; Reimus, P. W.
2013-12-01
In order to make safe and reasonable decisions about radioactive waste disposal in deep geologic sites, it is important to understand the fate and potential transport of long half-life transuranic radionuclides over a wide range of time and distance scales. The objective of this study was to evaluate and demonstrate new experimental methods for quantifying the potential for actinide transport in deep fractured crystalline rock formations. We selected a fractured/weathered granodiorite at the Grimsel Test Site (GTS) in Switzerland as a model system because field experiments involving uranium, as well as other actinides, have already been conducted. Working on this system provides a unique opportunity to compare lab experimental results with field-scale observations. Drilled rock cores and weathered fracture fill material (FFM) from the GTS were shipped to Los Alamos National Laboratory, characterized by x-ray diffraction and microscopy, and used in batch sorption/desorption and column breakthrough experiments. Uranium solutions were made by adding uranium to a synthetic Grimsel groundwater that matched the natural water chemistry found in the GTS groundwater. Batch and breakthrough experiments were conducted using solutions between pH 6.9 and 9.0. All column experiments were conducted using syringe pumps at low flow rate (<0.3 ml h-1) in small columns containing 5 g of material with pore volumes of 2-3 ml. These small columns allow rapid and economical evaluation of sorption/desorption behavior under flowing conditions (and in duplicate or triplicate). Solutions were switched to uranium-free synthetic Grimsel groundwater after equilibration in batch experiments or after near-steady uranium breakthrough occurred in column experiments. The measurement of uranium concentrations as a function of time under these conditions allowed interrogation of desorption rates which we believe control uranium fate and transport over long time and distance scales. Uranium transport was conservative and matched tritium breakthrough for pH 9.0; however, retardation increased when pH was reduced to 7.9 and 6.9. We are currently evaluating uranium adsorption/desorption rates as a function of water chemistry (initial focus on pH), with future testing planned to evaluate the influence of carbonate concentrations, flow rates, mineralogy, bentonite colloids and other actinides (e.g., Am). Figure 1. Uranium breakthrough results for (a) 6.5 μM U, (b) U-free solution, (c) flow rate increased from 0.3 to 0.6 mL h-1, (d) pH increased from 6.8 to 7.2, and (e) pH increased from 7.2 to 8.8.
NASA Astrophysics Data System (ADS)
Boddohi, Soheil; Killingsworth, Christopher; Kipper, Matt
2008-03-01
Chitosan (a weak polycation) and heparin (a strong polyanion) are used to make polyelectrolyte multilayers (PEM). PEM thickness and composition are determined as a function of solution pH (4.6 to 5.8) and ionic strength (0.1 to 0.5 M). Over this range, increasing pH increases the PEM thickness; however, the sensitivity to changes in pH is a strong function of ionic strength. The PEM thickness data are correlated to the polymer conformation in solution. Polyelectrolyte conformation in solution is characterized by gel permeation chromatography (GPC). The highest sensitivity of PEM structure to pH is obtained at intermediate ionic strength. Different interactions govern the conformation and adsorption phenomena at low and high ionic strength, leading to reduced sensitivity to solution pH at extreme ionic strengths. The correspondence between PEM thickness and polymer solution conformation offers opportunities to tune polymer thin film structure at the nanometer length scale by controlling simple, reproducible processing conditions.
α-keratin/Alginate Biosorbent for Removal of Methylene Blue on Aqueous Solution in a Batch System
NASA Astrophysics Data System (ADS)
Fadillah, G.; Putri, E. N. K.; Febrianastuti, S.; Munawaroh, H.; Purnawan, C.; Wahyuningsih, S.
2018-03-01
Methylene Blue (MB) is a cationic dyes which is commonly used in textile industries for coloring agent. The precence of MB in water caused some negative effect on the environment and human health. Many common technologies such as membrane filtration, electrophoresis and adsorption have been widely empolyed for removal of MB in water, but the adsorption technique still has advantages than the others. In this study, removal of MB used a biosorbent α-keratin/alginate (KA). The biosorbent KA was prepared by using the encapsulation technique in CaCl2 2 % (w/v) solution. The biosorbent was characterized by Fourier Transform Infrared (FTIR) and Scanning Electron Microscope (SEM). The effect of composition of α-keratin and alginate, the pH of solution and contact time on the adsorption were investigated. The optimum adsorption of MB in aqueous solution was found at the composition of α-keratin and alginate of 1:2 (w/w), the pH at 5.0 and contact time at 4 hours. The adsorption of MB on KA biosorbent was comparatively higher than α-keratin and alginate only. Adsorption of MB dyes in aqueous solution followed the Langmuir adsorption isotherm, and the dynamic adsorption model could be described through a pseudo-second order kinetics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Priyotomo, Gadang, E-mail: gada001@lipi.go.id; Nuraini, Lutviasari, E-mail: Lutviasari@gmail.com; Kaneno, Yasuyuki, E-mail: kaneno@mtr.osakafu-u.ac.id
The corrosion behavior of the intermetallic compounds, Ni{sub 3}(Si,Ti) (L1{sub 2}: single phase) and Ni{sub 3}(Si,Ti) + 2Mo (L1{sub 2} and (L12 + Ni{sub ss}) mixture region), has been investigated using an immersion test, electrochemical method and surface analytical method (SEM; scanning electron microscope and EDAX: Energy Dispersive X-ray) in 0.5 kmol/m{sup 3} NaCl solutions at various pH. The corrosion behavior of nickel alloy C-276 was studied under the same experimental conditions as a reference. It was found that the uniform attack was observed on Ni{sub 3}(Si,Ti) for the immersion test at lower pH, while the pitting attack was observedmore » on this compound for this test at neutral solution. Furthermore, Ni{sub 3}(Si,Ti)+2Mo had the preferential dissolution of L1{sub 2} compared to (L1{sub 2} + Ni{sub ss}) mixture region at lower pH, while pitting attack occurred in (L1{sub 2} + Ni{sub ss}) mixture region at neutral solution. For both intermetallic compounds, the magnitude of pitting and uniform attack decrease with increasing pH of solutions. From the immersion test and polarization curves, the corrosion resistance of Ni{sub 3}(Si,Ti)+2Mo is lower than that of Ni{sub 3}(Si,Ti), while the nickel alloy C-276 is the highest one at various pH of solutions. On the other hand, in the lower pH of solutions, the corrosion resistance of tested materials decreased significantly compared to those in neutral and higher pH of solutions.« less
Consolati, Tanja; Bolivar, Juan M; Petrasek, Zdenek; Berenguer, Jose; Hidalgo, Aurelio; Guisán, Jose M; Nidetzky, Bernd
2018-02-28
The pH is fundamental to biological function and its measurement therefore crucial across all biosciences. Unlike homogenous bulk solution, solids often feature internal pH gradients due to partition effects and confined biochemical reactions. Thus, a full spatiotemporal mapping for pH characterization in solid materials with biological systems embedded in them is essential. In here, therefore, a fully biocompatible methodology for real-time optical sensing of pH within porous materials is presented. A genetically encoded ratiometric pH sensor, the enhanced superfolder yellow fluorescent protein (sYFP), is used to functionalize the internal surface of different materials, including natural and synthetic organic polymers as well as silica frameworks. By using controlled, tailor-made immobilization, sYFP is homogenously distributed within these materials and so enables, via self-referenced imaging analysis, pH measurements in high accuracy and with useful spatiotemporal resolution. Evolution of internal pH is monitored in consequence of a proton-releasing enzymatic reaction, the hydrolysis of penicillin by a penicillin acylase, taking place in solution or confined to the solid surface of the porous matrix. Unlike optochemical pH sensors, which often interfere with biological function, labeling with sYFP enables pH sensing without altering the immobilized enzyme's properties in any of the materials used. Fast response of sYFP to pH change permits evaluation of biochemical kinetics within the solid materials. Thus, pH sensing based on immobilized sYFP represents a broadly applicable technique to the study of biology confined to the internally heterogeneous environment of solid matrices.
NASA Astrophysics Data System (ADS)
Kim, Yong-Hyun; Zhang, S. B.
2006-03-01
Despite being one of the most important macroscopic measures and a long history even before the quantum mechanics, the concept of pH has rarely been mentioned in microscopic theories, nor being incorporated computationally into first-principles theory of aqueous solutions. Here, we formulate a theory for the pH dependence of solution formation energy by introducing the proton chemical potential as the microscopic counterpart of pH in atomistic solution models. Within the theory, the general acid-base chemistry can be cast in a simple pictorial representation. We adopt density-functional molecular dynamics to demonstrate the usefulness of the method by studying a number of solution systems including water, small solute molecules such as NH3 and HCOOH, and more complex amino acids with several functional groups. For pure water, we calculated the auto- ionization constant to be 13.2 with a 95 % accuracy. For other solutes, the calculated dissociation constants, i.e., the so- called pKa, are also in reasonable agreement with experiments. Our first-principles pH theory can be readily applied to broad solution chemistry problems such as redox reactions.
Leaching of Metal Pollutants from Four Well Casings Used for Ground-Water Monitoring
1989-09-01
Atomic Spectroscopy, 4:126-128. 10 APPENDIX A : LEVELS OF CD, PB, CR, BA AND CU DETERMINED IN GROUND-WATER SOLUTIONS (MG/L). Time Pqle R:ph’itc (day1s...7 Conclusion ................................................... 9 Literature cited ................................................ 9 Appendix A ... Levels of Cd, Pb, Cr, Ba and Cu determined in ground-water solutions .................................................. 11 ILLUSTRATIONS Figure 1. Ground
9 CFR 93.904 - Health certificate for live fish, fertilized eggs, and gametes.
Code of Federal Regulations, 2012 CFR
2012-01-01
.... Acceptable disinfection procedures include individual or combination treatments with: Solutions having a pH of 12 or higher or 3 or lower with a contact time of at least 10 minutes; heat at or above 56 °C for at least 15 minutes; chlorine solutions having a concentration of at least 500 ppm with a contact...
9 CFR 93.904 - Health certificate for live fish, fertilized eggs, and gametes.
Code of Federal Regulations, 2013 CFR
2013-01-01
.... Acceptable disinfection procedures include individual or combination treatments with: Solutions having a pH of 12 or higher or 3 or lower with a contact time of at least 10 minutes; heat at or above 56 °C for at least 15 minutes; chlorine solutions having a concentration of at least 500 ppm with a contact...
Surface functionalized composite nanofibers for efficient removal of arsenic from aqueous solutions.
Mohamed, Alaa; Osman, T A; Toprak, M S; Muhammed, M; Uheida, A
2017-08-01
A novel composites nanofiber was synthesized based on PAN-CNT/TiO 2 -NH 2 nanofibers using electrospinning technique followed by chemical modification of TiO 2 NPs. PAN-CNT/TiO 2 -NH 2 nanofiber were characterized by XRD, FTIR, SEM, and TEM. The effects of various experimental parameters such as initial concentration, contact time, and solution pH on As removal were investigated. The maximum adsorption capacity at pH 2 for As(III) and As(V) is 251 mg/g and 249 mg/g, respectively, which is much higher than most of the reported adsorbents. The adsorption equilibrium reached within 20 and 60 min as the initial solution concentration increased from 10 to 100 mg/L, and the data fitted well using the linear and nonlinear pseudo first and second order model. Isotherm data fitted well to the linear and nonlinear Langmuir, Freundlich, and Redlich-Peterson isotherm adsorption model. Desorption results showed that the adsorption capacity can remain up to 70% after 5 times usage. This work provides a simple and an efficient method for removing arsenic from aqueous solution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nickel(II) biosorption from aqueous solutions by shrimp head biomass.
Hernández-Estévez, Alejandro; Cristiani-Urbina, Eliseo
2014-11-01
The present study evaluates the capacity of shrimp (Farfantepenaeus aztecus) head to remove toxic Ni(II) ions from aqueous solutions. Relevant parameters that could affect the biosorption process, such as shrimp head pretreatment, solution pH level, contact time and initial Ni(II) concentration, were studied in batch systems. An increase in Ni(II) biosorption capacity and a reduction in the time required to reach Ni(II) biosorption equilibrium was manifested by shrimp head biomass pretreated by boiling in 0.5 N NaOH for 15 min; this biomass was thereafter denominated APSH. The optimum biosorption level of Ni(II) ions onto APSH was observed at pH 7.0. Biosorption increased significantly with rising initial Ni(II) concentration. In terms of biosorption dynamics, the pseudo-second-order kinetic model described Ni(II) biosorption onto APSH best. The equilibrium data adequately fitted the Langmuir isotherm model within the studied Ni(II) ion concentration range. According to this isotherm model, the maximum Ni(II) biosorption capacity of APSH was 104.22 mg/g. Results indicate that APSH could be used as a low-cost, environmentally friendly, and promising biosorbent with high biosorption capacity to remove Ni(II) from aqueous solutions.
Department of Transportation Inhalation Test of Neutralized GB Hydrolysate in Sprague-Dawley Rats
2009-05-01
a product solution resulting from chemically neutralizing GB with aqueous sodium hydroxide ( pH 12.8) as an acceptably treated waste that can be...transported offsite for secondary treatment. An acute inhalation toxicity test was conducted on a ph adjusted hydrolysate solution ( pH 7.8) to assess...day post-exposure period, an endpoint of the DOT study. The product solution from the neutralized ( pH 7.8) hydrolysate does not appear to pose an
Removal of Cr(VI) from Aqueous Environments Using Micelle-Clay Adsorption
Qurie, Mohannad; Khamis, Mustafa; Manassra, Adnan; Ayyad, Ibrahim; Nir, Shlomo; Scrano, Laura; Bufo, Sabino A.; Karaman, Rafik
2013-01-01
Removal of Cr(VI) from aqueous solutions under different conditions was investigated using either clay (montmorillonite) or micelle-clay complex, the last obtained by adsorbing critical micelle concentration of octadecyltrimethylammonium ions onto montmorillonite. Batch experiments showed the effects of contact time, adsorbent dosage, and pH on the removal efficiency of Cr(VI) from aqueous solutions. Langmuir adsorption isotherm fitted the experimental data giving significant results. Filtration experiments using columns filled with micelle-clay complex mixed with sand were performed to assess Cr(VI) removal efficiency under continuous flow at different pH values. The micelle-clay complex used in this study was capable of removing Cr(VI) from aqueous solutions without any prior acidification of the sample. Results demonstrated that the removal effectiveness reached nearly 100% when using optimal conditions for both batch and continuous flow techniques. PMID:24222757
Surface Behavior of Iron Sulfide Ore during Grinding with Alumina Media
NASA Astrophysics Data System (ADS)
Martín, Reyes P.; Elia, Palácios B.; Patiño, Francisco C.; Escudero, Ramiro G.; Mizraim, Uriel Flores G.; Reyes, Iván A. D.; Palazuelos, Laura Angeles
This research was conducted to study the oxidation and surface modification of pyrite in an inert mill and alumina grinding media at different pH values. The extent and progress of the oxidation function of milling time, by measuring some physicochemical variables, zeta potential (ZP), infrared analysis and monitoring. The results indicate pyrite oxidation during grinding, releasing iron and sulfur ions to the solution increasing its concentration with the initial pH and the milling time, the ORP and DO decrease the grinding time, on the other hand presents negative values ZP pH of 9, 11 and 12, whereas at pH 5, 7 and 13, the ZP is positive, FTIR generally detect the presence of free sulfate ion molecule 1084 cm-1, goethite with the absorption band at about 794 cm-1, also occurs in a band assigned to 470 cm-1 lepidocrocite oxy iron hydroxide γ- FeOOH, nucleated species or formed during milling.
Johnson, David W; Clarke, Margaret; Wilson, Vanessa; Woods, Feidhlim; Brown, Fiona G
2010-09-16
The main hypothesis of this study is that neutral pH, low glucose degradation product (GDP) peritoneal dialysis (PD) fluid better preserves residual renal function in PD patients over time compared with conventional dialysate. Inclusion criteria are adult PD patients (CAPD or APD) aged 18-81 years whose first dialysis was within 90 days prior to or following enrolment and who have a residual GFR ≥ 5 ml/min/1.73 m2, a urine output ≥ 400 ml/day and an ability to understand the nature and requirements of this trial. Pregnant or lactating patients or individuals with an active infection at the time of enrolment, a contra-indication to PD or participation in any other clinical trial where an intervention is designed to moderate rate of change of residual renal function are excluded. Patients will be randomized 1:1 to receive either neutral pH, low GDP dialysis solution (Balance) or conventional dialysis solution (Stay.safe) for a period of 2 years. During this 2 year study period, urinary urea and clearance measurements will be performed at 0, 3, 6, 9, 12, 18 and 24 months. The primary outcome measure will be the slope of residual renal function decline, adjusted for centre and presence of diabetic nephropathy. Secondary outcome measures will include time from initiation of peritoneal dialysis to anuria, peritoneal small solute clearance, peritoneal transport status, peritoneal ultrafiltration, technique survival, patient survival, peritonitis rates and adverse events. A total of 185 patients has been recruited into the trial. This investigator-initiated study has been designed to provide evidence to help nephrologists determine the optimal dialysis solution for preserving residual renal function in PD patients. Australian New Zealand Clinical Trials Registry Number: ACTRN12606000044527.
2010-01-01
Background The main hypothesis of this study is that neutral pH, low glucose degradation product (GDP) peritoneal dialysis (PD) fluid better preserves residual renal function in PD patients over time compared with conventional dialysate. Methods/Design Inclusion criteria are adult PD patients (CAPD or APD) aged 18-81 years whose first dialysis was within 90 days prior to or following enrolment and who have a residual GFR ≥ 5 ml/min/1.73 m2, a urine output ≥ 400 ml/day and an ability to understand the nature and requirements of this trial. Pregnant or lactating patients or individuals with an active infection at the time of enrolment, a contra-indication to PD or participation in any other clinical trial where an intervention is designed to moderate rate of change of residual renal function are excluded. Patients will be randomized 1:1 to receive either neutral pH, low GDP dialysis solution (Balance®) or conventional dialysis solution (Stay.safe®) for a period of 2 years. During this 2 year study period, urinary urea and clearance measurements will be performed at 0, 3, 6, 9, 12, 18 and 24 months. The primary outcome measure will be the slope of residual renal function decline, adjusted for centre and presence of diabetic nephropathy. Secondary outcome measures will include time from initiation of peritoneal dialysis to anuria, peritoneal small solute clearance, peritoneal transport status, peritoneal ultrafiltration, technique survival, patient survival, peritonitis rates and adverse events. A total of 185 patients has been recruited into the trial. Discussion This investigator-initiated study has been designed to provide evidence to help nephrologists determine the optimal dialysis solution for preserving residual renal function in PD patients. Trial Registration Australian New Zealand Clinical Trials Registry Number: ACTRN12606000044527 PMID:20843375
Maniyar, Shaheen A; Jargar, Jameel G; Das, Swastika N; Dhundasi, Salim A; Das, Kusal K
2012-01-01
Objective To evaluate the alteration of chemical behavior of L-ascorbic acid (vitamin C) with metal ion (nickel) at different pH solutions in vitro. Methods Spectra of pure aqueous solution of L-ascorbic acid (E mark) compound and NiSO4 (H2O) (sigma USA) were evaluated by UV visible spectrophotometer. Spectral analysis of L-ascorbic acid and nickel at various pH (2.0, 7.0, 7.4 and 8.6) at room temperature of 29 °C was recorded. In this special analysis, combined solution of L-ascorbic acid and nickel sulfate at different pH was also recorded. Results The result revealed that λmax (peak wavelength of spectra) of L-ascorbic acid at pH 2.0 was 289.0 nm whereas at neutral pH 7.0, λmax was 295.4 nm. In alkaline pH 8.6, λmax was 295.4 nm and at pH 7.4 the λmax of L-ascorbic acid remained the same as 295.4 nm. Nickel solution at acidic pH 2.0 was 394.5 nm, whereas at neutral pH 7.0 and pH 7.4 were the same as 394.5 nm. But at alkaline pH 8.6, λmax value of nickel sulfate became 392.0 nm. The combined solution of L-ascorbic acid and nickel sulfate (6 mg/mL each) at pH 2.0 showed 292.5 nm and 392.5 nm, respectively whereas at pH 7.0, L-ascorbic acid showed 296.5 nm and nickel sulfate showed 391.5 nm. At pH 7.4, L-ascorbic acid showed 297.0 nm and nickel sulfate showed 394.0 nm in the combined solution whereas at pH 8.6 (alkaline) L-ascorbic acid and nickel sulfate were showing 297.0 and 393.5 nm, respectively. Conclusions Results clearly indicate an altered chemical behavior of L-ascorbic acid either alone or in combination with nickel sulfate in vitro at different pH. Perhaps oxidation of L-ascorbic acid to L-dehydro ascorbic acid via the free radical (HSc*) generation from the reaction of H2ASc + Ni (II) is the cause of such alteration of λmax value of L-ascorbic acid in the presence of metal nickel. PMID:23569901
Dai, Chun-Guang; Du, Xiao-Jiao; Song, Qin-Hua
2015-12-18
A Michael addition is usually taken as a base-catalyzed reaction. Most fluorescent probes have been designed to detect thiols in slightly alkaline solutions (pH 7-9). The sensing reactions of almost all Michael-type fluorescent probes for thiols are faster in a high pH solution than in a low pH solution. In this work, we synthesized a series of 7-substituted 2-(quinolin-2-ylmethylene)malonic acids (QMAs, substituents: NEt2, OH, H, Cl, or NO2) and their ethyl esters (QMEs) as Michael-type fluorescent probes for thiols. The sensing reactions of QMAs and QMEs occur in distinct pH ranges, pH < 7 for QMAs and pH > 7 for QMEs. On the basis of experimental and theoretic studies, we have clarified the distinct pH effects on the sensing reactivity between QMAs and QMEs and demonstrated that two QMAs (NEt2, OH) are highly sensitive and selective fluorescent probes for thiols in acidic solutions (pH < 7) and promising dyes that can label lysosomes in live cells.
Sanagi, Mohd Marsin; Miskam, Mazidatulakmam; Wan Ibrahim, Wan Aini; Hermawan, Dadan; Aboul-Enein, Hassan Y
2010-07-01
A three-phase hollow fiber liquid-phase microextraction method coupled with CE was developed and used for the determination of partition coefficients and analysis of selected nitrophenols in water samples. The selected nitrophenols were extracted from 14 mL of aqueous solution (donor solution) with the pH adjusted to pH 3 into an organic phase (1-octanol) immobilized in the pores of the hollow fiber and finally backextracted into 40.0 microL of the acceptor phase (NaOH) at pH 12.0 located inside the lumen of the hollow fiber. The extractions were carried out under the following optimum conditions: donor solution, 0.05 M H(3)PO(4), pH 3.0; organic solvent, 1-octanol; acceptor solution, 40 microL of 0.1 M NaOH, pH 12.0; agitation rate, 1050 rpm; extraction time, 15 min. Under optimized conditions, the calibration curves for the analytes were linear in the range of 0.05-0.30 mg/L with r(2)>0.9900 and LODs were in the range of 0.01-0.04 mg/L with RSDs of 1.25-2.32%. Excellent enrichment factors of up to 398-folds were obtained. It was found that the partition coefficient (K(a/d)) values were high for 2-nitrophenol, 3-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol and 2,6-dinitrophenol and that the individual partition coefficients (K(org/d) and K(a/org)) promoted efficient simultaneous extraction from the donor through the organic phase and further into the acceptor phase. The developed method was successfully applied for the analysis of water samples.
NASA Astrophysics Data System (ADS)
Finnegan, Michael Patrick
The effect of solution chemistry on the phase stability, coarsening kinetics and morphology of titanium dioxide (TiO2) nanoparticles is investigated in order to attain efficient production pathways to desired nano-structures with optimal properties. To obtain sample, TiO2 was synthesized via hydrolysis of titanium isopropoxide producing an 85% anatase/15% brookite mixture. The titania was hydrothermally heated in an array of temperatures and pH values for various times. There are distinct phase stability fields for nanoscale titania based on pH alone due to slight interface charging behavior differences among the polymorphs. The mixture transforms to rutile below the pH of zero point of charge (ZPC) and remains anatase above the ZPC. This phenomenon is partially reversible. The solution chemistry also dictates the hydrothermal coarsening mechanism of the anatase polymorph. Ostwald ripening (OR) takes place in basic pH where titania solubility is elevated relative to neutral pH where lower solubility prevents rapid OR but allows for coarsening via oriented attachment (OA) of nanoparticles. This OA event can alter the symmetry of anatase causing unexpected and perhaps technically useful morphologies such as straight and curved nanorods during coarsening.
Characterization of zinc oxide thin film for pH detector
NASA Astrophysics Data System (ADS)
Hashim, Uda; Fathil, M. F. M.; Arshad, M. K. Md; Gopinath, Subash C. B.; Uda, M. N. A.
2017-03-01
This paper presents the fabrication process of the zinc oxide thin films for using to act as pH detection by using different PH solution. Sol-gel solution technique is used for preparing zinc oxide seed solution, followed by metal oxide deposition process by using spin coater on the silicon dioxide. Silicon dioxide layer is grown on the silicon wafer, then, ZnO seed solution is deposited on the silicon layer, baked, and annealing process carried on to undergo the characterization of its surface morphology, structural and crystalline phase. Electrical characterization is showed by using PH 4, 7, and 10 is dropped on the surface of the die, in addition, APTES solution is used as linker and also as a references of the electrical characterization.
Mani, Ganesh Kumar; Miyakoda, Kousei; Saito, Asuka; Yasoda, Yutaka; Kajiwara, Kagemasa; Kimura, Minoru; Tsuchiya, Kazuyoshi
2017-07-05
Acid-base homeostasis (body pH) inside the body is precisely controlled by the kidneys and lungs and buffer systems, such that even a minor pH change could severely affect many organs. Blood and urine pH tests are common in day-to-day clinical trials and require little effort for diagnosis. There is always a great demand for in vivo testing to understand more about body metabolism and to provide effective diagnosis and therapy. In this article, we report the simple fabrication of microneedle-based direct, label-free, and real-time pH sensors. The reference and working electrodes were Ag/AgCl thick films and ZnO thin films on tungsten (W) microneedles, respectively. The morphological and structural characteristics of microneedles were carefully investigated through various analytical methods. The developed sensor exhibited a Nernstian response of -46 mV/pH. Different conditions were used to test the sensor to confirm their accuracy and stability, such as various buffer solutions, with respect to time, and we compared the reading with commercial pH electrodes. Besides that, the fabricated microneedle sensor ability is proven by in vivo testing in mouse cerebrospinal fluid (CSF) and bladders. The pH sensor procedure reported here is totally reversible, and results were reproducible after several rounds of testing.
One step effective removal of Congo Red in chitosan nanoparticles by encapsulation
NASA Astrophysics Data System (ADS)
Alver, Erol; Bulut, Mehmet; Metin, Ayşegül Ülkü; Çiftçi, Hakan
2017-01-01
Chitosan nanoparticles (CNPs) were prepared with ionotropic gelation between chitosan and tripolyphosphate for the removal of Congo Red. The production of chitosan nanoparticles and the dye removal process was carried out in one-step. The removal efficiency of Congo Red by encapsulation within chitosan from the aqueous solution and its storage stability are examined at different pH values. The influence of some parameters such as the initial dye concentration, pH value of the dye solution, electrolyte concentration, tripolyphosphate concentration, mixing time and speed on the encapsulation is examined. Congo Red removal efficiency and encapsulation capacity of chitosan nanoparticles were determined as above 98% and 5107 mg Congo Red/g chitosan, respectively.
Removal of mercury (II) from aqueous solution by activated carbon obtained from furfural.
Yardim, M F; Budinova, T; Ekinci, E; Petrov, N; Razvigorova, M; Minkova, V
2003-08-01
The adsorption of Hg(II) from aqueous solution at 293 K by activated carbon obtained from furfural is studied. The carbon is prepared by polymerization of furfural following carbonization and activation of the obtained polymer material with water vapor at 800 degrees C. Adsorption studies of Hg(II) are carried out varying some conditions: treatment time, metal ion concentration, adsorbent amount and pH. It is determined that Hg(II) adsorption follows both Langmuir and Freundlich isotherms. The adsorption capacity of the carbon is 174 mg/g. It is determined that Hg(II) uptake increases with increasing pH. Desorption studies are performed with hot water. The percent recovery of Hg(II) is 6%.
Chemical durability of glaze on Zsolnay architectural ceramics (Budapest, Hungary) in acid solutions
NASA Astrophysics Data System (ADS)
Baricza, Ágnes; Bajnóczi, Bernadett; May, Zoltán; Tóth, Mária; Szabó, Csaba
2015-04-01
Zsolnay glazed architectural ceramics are among the most famous Hungarian ceramics, however, there is no profound knowledge about the deterioration of these building materials. The present study aims to reveal the influence of acidic solutions in the deterioration of Zsolnay ceramics. The studied ceramics are glazed roof tiles, which originate from two buildings in Budapest: one is located in the densely built-up city centre with high traffic rate and another one is in a city quarter with moderate traffic and more open space. The roof tiles represent the construction and the renovation periods of the buildings. The ceramics were mainly covered by lead glazes in the construction period and mainly alkali glazes in the renovation periods. The glaze of the tiles were coloured with iron (for yellow glaze) or chromium/copper/iron (for green glazes) in the case of the building located in the city centre, whereas cobalt was used as colorant and tin oxide as opacifier for the blue glaze of the ceramics of the other building. Six tiles were selected from each building. Sulphuric acid (H2SO4) solutions of pH2 and pH4 were used to measure the durability of the glazes up to 14 days at room temperature. The surfaces of the glazed ceramics after the treatment were measured by X-ray diffraction, Raman spectroscopy and SEM-EDS techniques to determine the precipitated phases on the surface of the glaze. Electron microprobe analysis was used to quantitatively characterise phases found and to determine the chemical composition of the treated glaze. The recovered sulphuric acid solutions were measured with ICP-OES technique in order to quantify the extent of the ion exchange between the glaze and the solutions. There is a significant difference in the dissolution rates in the treatments with sulphuric acid solutions of pH2 and pH4, respectively. The solution of pH2 induced greater ion exchange (approx. 7-10 times) from the glaze compared to the solution of pH4. Alkali and alkali earth metals and lead indicate the most intensive dissolution. Greater amount of ion-exchange was observed for the lead glaze covering the ceramics from the construction periods of both buildings. Sulphate phases (e.g. anglesite, gypsum, anhydrite) newly appeared on corroded glaze parts and pits are clearly seen on the surface of the ceramics originated especially from the first renovation period of the building located in the city centre.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sundaramurthi, Prakash; Shalaev, Evgenyi; Suryanarayanan, Raj
2010-06-22
Sequential crystallization of succinate buffer components in the frozen solution has been studied by differential scanning calorimetry and X-ray diffractometry (both laboratory and synchrotron sources). The consequential pH shifts were monitored using a low-temperature electrode. When a solution buffered to pH < pK{sub a2} was cooled from room temperature (RT), the freeze-concentrate pH first increased and then decreased. This was attributed to the sequential crystallization of succinic acid, monosodium succinate, and finally disodium succinate. When buffered to pH > pK{sub a2}, the freeze-concentrate pH first decreased and then increased due to the sequential crystallization of the basic (disodium succinate) followedmore » by the acidic (monosodium succinate and succinic acid) buffer components. XRD provided direct evidence of the crystallization events in the frozen buffer solutions, including the formation of disodium succinate hexahydrate [Na{sub 2}(CH{sub 2}COO){sub 2} {center_dot} 6H{sub 2}O]. When the frozen solution was warmed in a differential scanning calorimeter, multiple endotherms attributable to the melting of buffer components and ice were observed. When the frozen solutions were dried under reduced pressure, ice sublimation was followed by dehydration of the crystalline hexahydrate to a poorly crystalline anhydrate. However, crystalline succinic acid and monosodium succinate were retained in the final lyophiles. The pH and the buffer salt concentration of the prelyo solution influenced the crystalline salt content in the final lyophile. The direction and magnitude of the pH shift in the frozen solution depended on both the initial pH and the buffer concentration. In light of the pH-sensitive nature of a significant fraction of pharmaceuticals (especially proteins), extreme care is needed in both the buffer selection and its concentration.« less
NASA Astrophysics Data System (ADS)
De Silvestri, S.; Laporta, P.
1984-01-01
Time-resolved and steady-state fluorescence studies of proflavine in aqueous solution are presented. The observation of a monoexponential fluorescence decay with a time constant decreasing with increasing pH and the presence of an anomalous red-shift in the fluorescence spectrum as a function of pH indicate the existence of a complex proton-transfer mechanism in the excited state. A reaction scheme is proposed and the corresponding proton-transfer rates are evaluated. An excited-state pK value of 12.85 is obtained for the equilibrium between the cationic form of proflavine and the same form dissociated at an amino group.
TOLENTINO, Elen de Souza; CHINELLATO, Luiz Eduardo Montenegro; TARZIA, Olinda
2011-01-01
Objectives The aim of this work was to evaluate saliva and tongue coating pH in oral healthy patients with morning bad breath before and after use of different oral mouthrinses. Material and Methods aliva and tongue coating pH of 50 patients allocated in 5 groups were measured respectively by a digital pHmeter and color pH indicators, before, immediately after and 30 min after rinsing 5 different mouthrinses: cetilpiridine chloride associated with sodium chloride, triclosan, enzymatic solution, essential oil and distilled water. Results Only triclosan and essential oil increased salivary pH immediately after rising. The enzymatic solution decreased salivary and tongue coating pH immediately after rinsing. Conclusion Salivary pH tended to be acidic while tongue coating pH tended to be alkaline, even after rising. Triclosan and essential oil mouthrinses increased salivary pH immediately after rinsing. Enzymatic solution decreased saliva and tongue coating pH immediately after rising. PMID:21552707
Khalil, E; Sallam, A
1999-04-01
The copolymer of ammoniomethacrylate Eudragit RL (ERL) interacted with diclofenac acid salts (sodium and diethylamine salts) in aqueous solutions, forming a complex. Sorption experiments were done in aqueous solutions of either sodium lauryl sulfate (SLS), Tween 20, or Tween 80. The SLS competed strongly with the drug, even at low concentrations, and reduced significantly the amount of drug sorbed by ERL. Tweens at high concentrations exhibited two phase profiles: the sorption phase, which was short and during which drug concentration dropped sharply, and the release phase, during which the drug was released slowly over 24 hr and which was accompanied by dispersion of ERL particles into the colloidal dispersion. The interaction was dependent on temperature, ionic strength, and nature of the additives. The extent of interaction in water and phosphate buffer solutions was in the following order: water > pH 6 > pH 7-8. In-vitro dissolution studies of the dried complex were done over 24 hr. In water, the drug remained bound to the polymer. In aqueous surfactant solutions (SLS, Tween 20, and Tween 80) and phosphate buffer at pH 6.8, a linear relationship between drug concentration and the square root of time was obtained, indicating a matrix diffusion-controlled mechanism. However, 100% release was not reached, and resorption was observed in the phosphate buffer solution.
Li, Cun-Yu; Liu, Li-Cheng; Jin, Li-Yang; Li, Hong-Yang; Peng, Guo-Ping
2017-07-01
To separate chlorogenic acid from low concentration ethanol and explore the influence of Donnan effect and solution-diffusion effect on the nanofiltration separation rule. The experiment showed that solution pH and ethanol volume percent had influences on the separation of chlorogenic acid. Within the pH values from 3 to 7 for chlorogenic acid in 30% ethanol, the rejection rate of chlorogenic acid was changed by 70.27%. Through the response surface method for quadratic regression model, an interaction had been found in molecule weight cut-off, pH and ethanol volume percent. In fixed nanofiltration apparatus, the existence states of chlorogenic acid determinedits separation rules. With the increase of ethanol concentration, the free form chlorogenic acid was easily adsorbed, dissolved on membrane surface and then caused high transmittance due to the solution-diffusion effect. However, at the same time, due to the double effects of Donnan effect and solution-diffusion effect, the ionic state of chlorogenic acid was hard to be adsorbed in membrane surface and thus caused high rejection rate. The combination of Box-Behnken design and response surface analysis can well optimize the concentrate process by nanofiltration, and the results showed that nanofiltration had several big advantages over the traditional vacuum concentrate technology, meanwhile, and solved the problems of low efficiency and serious component lossesin the Chinese medicines separation process for low concentration organic solvent-water solution. Copyright© by the Chinese Pharmaceutical Association.
Chemical interactions of aluminum with aqueous silica at 25 degrees Celsius
Hem, John David; Roberson, C.E.; Lind, Carol J.; Polxer, W.L.
1973-01-01
Solutions containing from 10 -5 to 10 -2 moles per liter of aluminum and dissolved silica in various ratios were aged at pH levels between 4 and 10 at 25?C. A colloidal amorphous product having the composition of halloysite was produced in most solutions. It had a consistent and reversible equilibrium solubility equivalent to a standard free energy of formation of -8974 ? 1.0 kcal per mole for the formula A12Si2O5(OH)4. Some aging times were longer than 4 years, but most solutions gave consistent solubilities after only a few months of aging. Where silica concentrations were below about 10 -4 molar, microcrystalline gibbsite was formed below pH 6.0 and crystalline bayerite above pH 7.0, but only after much longer aging than was required for crystallization in silica-free solutions. Electron micrographs and diffraction patterns of the synthesized material indicate some crystallinity in the aluminosilicate, but no X-ray diffraction patterns could be obtained even in the material aged 4 years. Solubility relationships for solutions containing fluoride as well as silica and aluminum are explainable by using cryolite stabilities determined in previous work. Aluminum contents of 51 samples of water analyzed for other purposes are in reasonable agreement with the assumption of equilibrium with amorphous clay mineral species similar to the material synthesized in this work. Solubility calculations are summarized graphically for solutions of ionic strength of 0.01 and 0.10.
NASA Astrophysics Data System (ADS)
Kurake, Naoyuki; Tanaka, Hiromasa; Ishikawa, Kenji; Nakamura, Kae; Kajiyama, Hiroaki; Kikkawa, Fumitaka; Mizuno, Masaaki; Ikehara, Yuzuru; Hori, Masaru
2017-10-01
Oxalate was synthesized in the glucose solution by irradiation with non-equilibrium atmospheric pressure plasma (NEAPP), in which the NEAPP plume contacted the solution surface, via the generation of several intermediate organic products such as gluconic acid. A thermodynamically unstable phase of calcium oxalate dihydrate crystallized rapidly during incubation of a NEAPP-irradiated glucose solution that contained calcium ions and was buffered at neutral pH. Longer irradiation times increased the growth rate and the number of seed crystals.
Technetium recovery from high alkaline solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nash, Charles A.
2016-07-12
Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.
ANTICARIOGENIC POTENCIAL OF ACIDULATE SOLUTIONS WITH LOW FLUORIDE CONCENTRATION
Delbem, Alberto Carlos Botazzo; Tiano, Gilberto Carlos; Alves, Karina Mirela Ribeiro Pinto; Cunha, Robson Frederico
2006-01-01
Objectives: The aim of this study was to verify the anticariogenic effect of acidulate solutions with low NaF concentration, using pH-cycling model and bovine enamel. Material and methods: Enamel blocks were submitted to the surface microhardness (SMH) test and randomly divided in 12 experimental and one placebo groups. The blocks were submitted to pH cycling for 7 days, with daily applications once/day of 0.05% NaF and 0.1% NaF and twice/day of 0.02% NaF solutions. Four different pH: 4.0, 5.0, 6.0 and 7.0 were used. Next, SMH test was again used to determine the surface microhardness percentage change (%SMH). Data obtained for %SMH were homogeneous and passed through variance analyses and Tukey's test (5%) as far as fluoride concentrations and pH. Results: The results showed that pH influenced %SMH in 0.02% NaF and 0.05% NaF solutions with pH 4.0, which had less mineral loss compared to pH 7.0 (p<0.05). The 0.02% NaF - pH 4.0, and 0.05% NaF – pH 7.0 groups showed similar results (p>0.05). A dose-response relationship was observed among the tested solutions, with better anticariogenic effect for the 0.1% NaF solution. Conclusion: The results suggest that the addition of citric acid to acidulate mouth rinses reduce mineral loss. PMID:19089268
Ghiani, Alessandra; Bruschi, Maurizio; Citterio, Sandra; Bolzacchini, Ezio; Ferrero, Luca; Sangiorgi, Giorgia; Asero, Riccardo; Perrone, Maria Grazia
2016-12-15
Pollen aeroallergens are present in atmospheric particulate matter (PM) where they can be found in coarse biological particles such as pollen grains (aerodynamic diameter d ae >10μm), as well as fragments in the finest respirable particles (PM2.5; d ae <2.5μm). Nitration of tyrosine residues in pollen allergenic proteins can occur in polluted air, and inhalation and deposition of these nitrated proteins in the human respiratory tract may lead to adverse health effects by enhancing the allergic response in population. Previous studies investigated protein nitration by atmospheric gaseous pollutants such as nitrogen dioxide and ozone. In this work we report, for the first time, a study on protein nitration by nitrate ion in aqueous solution, at nitrate concentrations and pH conditions simulating those occurring in the atmospheric aerosol liquid water phase. Experiments have been carried out on the Bovine serum albumin (BSA) protein and the recombinant Phleum pratense allergen (Phl p 2) both in the dark and under UV-A irradiation (range 4-90Wm -2 ) to take into account thermal and/or photochemical nitration processes. For the latter protein, modifications in the allergic response after treatment with nitrate solutions have been evaluated by immunoblot analyses using sera from grass-allergic patients. Experimental results in bulk solutions showed that protein nitration in the dark occurs only in dilute nitrate solutions and under very acidic conditions (pH<3 for BSA; pH<2.2 for Phl p 2), while nitration is always observed (at pH0.5-5) under UV-A irradiation, both in dilute and concentrated nitrate solutions, being significantly enhanced at the lowest pH values. In some cases, protein nitration resulted in an increase of the allergic response. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Pranoto; Masykur, A.; Nugroho, Y. A.
2018-03-01
Adsorption of chromium hexavalent (Cr(VI)) ion in aqueous solution was investigated. This research was purposed to study the influence of the composition of ACZ, temperature activation, and contact time against adsorption capacity of Cr(VI) ion in aqueous solution. Determination of adsorption effectivity using several parameter such as composition variation of ACZ, contact time, pH, activation temperature, and concentration. In this research, andisol clay and zeolite has been activated with NaOH 3 M and 1 M, respectively. Temperature variation used 100, 200, and 400°C. While composition variation ACZ used 0:100, 25:75, 50:50, 75:25, 100:0. The pH variation was used 2 – 6 and concentration variation using 2, 4, 6, 8, 10, and 12 ppm. Characterization in this research used such as UV-Vis, Surface Area Analyzer (SAA) and Acidity Analysis. Result of this research is known that optimum composition of ACZ was 50:50 with calcination temperature 100°C. Optimum adsorption of Cr(VI) at pH 4 with removal percentage 76.10 % with initial concentration 2 ppm and adsorption capacity is 0.16 mg/g. Adsorption isotherm following freundlich isotherm with value Kf = 0.17 mg/g and value n is 0.963. Based on results, ACZ composite can be used as Cr(VI) ion adsorbents in aqueous solutions.
Naghizadeh, Ali; Shahabi, Habibeh; Ghasemi, Fatemeh; Zarei, Ahmad
2016-12-01
The main aim of this research was to study the efficiency of modified walnut shell with titanium dioxide (TiO 2 ) and zinc oxide (ZnO) in the adsorption of humic acid from aqueous solutions. This experimental study was carried out in a batch condition to determine the effects of factors such as contact time, pH, humic acid concentration, dose of adsorbents (raw walnut shell, modified walnut shell with TiO 2 and ZnO) on the removal efficiency of humic acid. pH zpc of raw walnut shell, walnut shell modified with TiO 2 and walnut shell modified with ZnO were 7.6, 7.5, and 8, respectively. The maximum adsorption capacity of humic acid at concentration of 30 mg/L, contact time of 30 min at pH = 3 in an adsorbent dose of 0.02 g of walnut shell and ZnO and TiO 2 modified walnut shell were found to be 35.2, 37.9, and 40.2 mg/g, respectively. The results showed that the studied adsorbents tended to fit with the Langmuir model. Walnut shell, due to its availability, cost-effectiveness, and also its high adsorption efficiency, can be proposed as a promising natural adsorbent in the removal of humic acid from aqueous solutions.
The Semen pH Affects Sperm Motility and Capacitation.
Zhou, Ji; Chen, Li; Li, Jie; Li, Hongjun; Hong, Zhiwei; Xie, Min; Chen, Shengrong; Yao, Bing
2015-01-01
As the chemical environment of semen can have a profound effect on sperm quality, we examined the effect of pH on the motility, viability and capacitation of human sperm. The sperm in this study was collected from healthy males to avoid interference from other factors. The spermatozoa cultured in sperm nutrition solution at pH 5.2, 6.2, 7.2 and 8.2 were analyzed for sperm total motility, progressive motility (PR), hypo-osmotic swelling (HOS) rate, and sperm penetration. Our results showed that these parameters were similar in pH 7.2 and 8.2 sperm nutrition solutions, but decreased in pH 5.2 and 6.2 solutions. The HOS rate exhibited positive correlation with the sperm total motility and PR. In addition, the sperm Na(+)/K(+)-ATPase activity at different pHs was measured, and the enzyme activity was significantly lower in pH 5.2 and 6.2 media, comparing with that in pH 8.2 and pH 7.2 solutions. Using flow cytometry (FCM) and laser confocal scanning microscopy (LCSM) analysis, the intracellular Ca2(+ )concentrations of sperm cultured in sperm capacitation solution at pH 5.2, 6.2, 7.2 and 8.2 were determined. Compared with that at pH 7.2, the mean fluorescence intensity of sperm in pH 5.2 and 6.2 media decreased significantly, while that of pH 8.2 group showed no difference. Our results suggested that the declined Na(+)/K(+)-ATPase activity at acidic pHs result in decreased sperm movement and capacitation, which could be one of the mechanisms of male infertility.
A Study to Draw a Normative Database of Laryngopharynx pH Profile in Chinese
Feng, Guijian; Wang, Junyao; Zhang, Lihong; Liu, Yulan
2014-01-01
Background/Aims To draw a normative database of laryngopharynx pH profile in Chinese subjects. Methods Normal volunteers were recruited from “www.Ganji.com” and People’s hospital between May 2008 and December 2009. The Restech pH Probes were calibrated in pH 7 and pH 4 buffer solutions according to the manufacturer's instructions. Each volunteer was asked to wear the device for a 24-hour period and was encouraged to participate in normal daily activities. Results The healthy volunteers consisted of 20 males and 9 females with a median age of 23 years (interquartile range, 21 to 32 years). The 95th percentiles for % total times at pH < 4, pH < 4.5, pH < 5.0 and pH < 5.5 for the oropharynx pH catheter were 0.06%, 1.01%, 7.23% and 27.34%, respectively. The 95th percentile for number of reflux events within the 24-hour period at pH < 4, pH < 4.5, pH < 5.0 and pH < 5.5 were 2.0, 18.0, 107.5 and 284.5, respectively. Conclusions This is the first study to systematically assess the degree of reflux detected by the new pH probe in healthy asymptomatic Chinese volunteers and to report normative values in Chinese people. Using an oropharyngeal pH catheter to monitor laryngopharyngeal reflux indicated that in healthy Chinese, reflux should be considered normal if the percent time at pH less than 4.5 is no more than 1%. PMID:24948130
NASA Astrophysics Data System (ADS)
Kusmiyati, L., Puspita Adi; Deni, V.; Robi Indra, S.; Islamica, Dlia; Fuadi, M.
2016-04-01
Removal of vertigo blue dye from batik textile wastewater was studied by adsorptionprocess onto activated carbon (AC) and coal bottom ash (CBA).The influence of experimental conditions (pH solution, dye concentration, and contact time) were studied on the both adsorbents. At equilibrium conditions, the data were fitted to Langmuir and Freundlich adsorption models. The maximum adsorption capacity calculated from the Langmuir model for carbon active was 6.29mg/g at pH that found to be considerably higher than that obtained for coal bottom ash 3.72mg/g pH 9. From Freundlich model, the maximum adsorption capacity is less for coal bottom ash (pH 9) than that for carbon active (pH4).
NASA Astrophysics Data System (ADS)
Balesini, A. A.; Zakeri, A.; Razavizadeh, H.; Khani, A.
2013-11-01
Cold purification filter cakes generated in the hydrometallurgical processing of Angouran mine zinc concentrate commonly contain significant amounts of Zn, Cd, and Ni ions and thus are valuable resources for metal recovery. In this research, a nickel containing solution that was obtained from sulfuric acid leaching of the filter cake following cadmium and zinc removal was subjected to solvent extraction experiments using 10vol% LIX984N diluted in kerosene. Under optimum experimental conditions (pH 5.3, volume ratio of organic/aqueous (O:A) = 2:1, and contact time = 5 min), more than 97.1% of nickel was extracted. Nickel was stripped from the loaded organic by contacting with a 200 g/L sulfuric acid solution, from which 77.7% of nickel was recovered in a single contact at the optimum conditions (pH 1-1.5, O:A = 5:1, and contact time = 15 min).
Inkjet-printed Polyvinyl Alcohol Multilayers.
Salaoru, Iulia; Zhou, Zuoxin; Morris, Peter; Gibbons, Gregory J
2017-05-11
Inkjet printing is a modern method for polymer processing, and in this work, we demonstrate that this technology is capable of producing polyvinyl alcohol (PVOH) multilayer structures. A polyvinyl alcohol aqueous solution was formulated. The intrinsic properties of the ink, such as surface tension, viscosity, pH, and time stability, were investigated. The PVOH-based ink was a neutral solution (pH 6.7) with a surface tension of 39.3 mN/m and a viscosity of 7.5 cP. The ink displayed pseudoplastic (non-Newtonian shear thinning) behavior at low shear rates, and overall, it demonstrated good time stability. The wettability of the ink on different substrates was investigated, and glass was identified as the most suitable substrate in this particular case. A proprietary 3D inkjet printer was employed to manufacture polymer multilayer structures. The morphology, surface profile, and thickness uniformity of inkjet-printed multilayers were evaluated via optical microscopy.
Adsorption of heavy metal ions by sawdust of deciduous trees.
Bozić, D; Stanković, V; Gorgievski, M; Bogdanović, G; Kovacević, R
2009-11-15
The adsorption of heavy metal ions from synthetic solutions was performed using sawdust of beech, linden and poplar trees. The adsorption depends on the process time, pH of the solution, type of ions, initial concentration of metals and the sawdust concentration in suspension. The kinetics of adsorption was relatively fast, reaching equilibrium for less than 20 min. The adsorption equilibrium follows Langmuir adsorption model. The ion exchange mechanism was confirmed assuming that the alkali-earth metals from the adsorbent are substituted by heavy metal ions and protons. On lowering the initial pH, the adsorption capacity decreased, achieving a zero value at a pH close to unity. The maximum adsorption capacity (7-8 mg g(-1) of sawdust) was achieved at a pH between 3.5 and 5 for all the studied kinds of sawdust. The initial concentration of the adsorbate and the concentration of sawdust strongly affect the process. No influence of particles size was evidenced. A degree of adsorption higher than 80% can be achieved for Cu(2+) ions but it is very low for Fe(2+) ions, not exceeding 10%.
A novel solution for hydroxylated PAHs removal by oxidative coupling reaction using Mn oxide.
Kang, Ki-Hoon; Lim, Dong-Min; Shin, Hyun-Sang
2008-01-01
In this study, removals of 1-naphthol by oxidative-coupling reaction using birnessite, one of the natural Mn oxides present in soil, was investigated in various experimental conditions (reaction time, Mn oxide loadings, pH). The removal efficiency of 1-naphthol by birnessite was high in all the experimental conditions, and UV-visible and mass spectrometric analyses on the supernatant after reaction confirmed that the reaction products were oligomers formed by oxidative-coupling reaction. Pseudo-first order rate constants, k, for the oxidative transformation of 1-naphthol by birnessite was derived from the kinetic experiments under various amounts of birnessite loadings, and using the observed pseudo-first order rate constants with respect to birnessite loadings, the surface area normalised specific rate constant, k(surf), was also determined to be 9.3 x 10(-4) (L/m(2).min) for 1-naphthol. In addition, the oxidative transformation of 1-naphthol was found to be dependent on solution pH, and the pseudo-first order rate constants were increased from 0.129 at pH 10 to 0.187 at pH 4. (c) IWA Publishing 2008.
Williams, E L; Hildebrand, K L; McCormick, S A; Bedel, M J
1999-05-01
Animal studies have shown that large volumes of IV lactated Ringer's solution (LR) decrease serum osmolality, thereby increasing cerebral water. These studies have led to recommendations to limit LR to avoid cerebral edema in neurosurgical patients. Eighteen healthy human volunteers aged 20-48 yr received 50 mL/kg LR over 1 h on one occasion and 0.9% sodium chloride (NS) on another. Venous samples were taken at baseline (T1), at infusion end (T2), and 1 h after T2 (T3). Time until first urination was noted. With LR, serum osmolality decreased by 4+/-3 mOsm/kg from T1 to T2 and increased insignificantly with NS. At T3, osmolality returned almost to baseline in the LR group. Blood pH increased from T1 to T2 with LR by 0.04+/-0.04 and decreased with NS by 0.04+/-0.04. These pH changes persisted at T3. Subjective mental changes occurred only with NS. Abdominal discomfort was more common with NS. Time until first urination was longer with NS (106+/-11 min) than with LR (75+/-10 min) (P < 0.001). In healthy humans, an infusion of large volumes of LR, but not NS, transiently decreased serum osmolality, whereas acidosis associated with NS persisted and urinary output was slower with NS. Large volumes of lactated Ringer's solution administered to healthy humans produced small transient changes in serum osmolality. Large volumes of sodium chloride did not change osmolality but resulted in lower pH.
The use of macroalgae (Gracilaria changii) as bio-adsorbent for Copper (II) removal
NASA Astrophysics Data System (ADS)
Lavania-Baloo; Idayu, Nordin; Umar Salihi, Ibrahim; Zainoddin, Jamari
2017-05-01
Biosorption of heavy metals using marine macroalgae biomass can be an effective process and alternative to conventional methods. Activated carbon was developed from macroalgae (Gracilaria changii) and used as adsorbents for the removal of copper (II) from wastewater. Gracilaria changii based activated carbon (GCBAC) was prepared using muffle furnace at a constant temperature of 300 °C for 1 hour. Batch adsorption experiments were conducted to investigate the effets of important parameters such as pH, contact time, initial metal concentration and adsorbent dosage on the removal of Cu (II) from synthetic aqueous solution. Batch adsorption study shows that removal of Cu (II) using GCBAC relied upon pH, contact time, initial metal concentration and GCBAC dosage. The optimum conditions parameters were found to be pH 6.0, time of 60 minutes and GCBAC dosage of 0.3 g, respectively. Adsorption data was described better by Freundlich isotherm model with R2 value of 0.7936. The maximum Cu (II) adsorption capacity of GCBAC was found to be 0.07 mg/g. The experimental adsorption data obtained fitted well into Pseudo-second-order kinetic model, with R2 value near unity. Thus, GCBAC can be used as an effective adsorbent for the removal of Cu (II) from aqueous solution.
NASA Astrophysics Data System (ADS)
Aghajani, Khadijeh; Tayebi, Habib-Allah
2017-01-01
In this study, the Mesoporous material SBA-15 were synthesized and then, the surface was modified by the surfactant Cetyltrimethylammoniumbromide (CTAB). Finally, the obtained adsorbent was used in order to remove Reactive Red 198 (RR 198) from aqueous solution. Transmission electron microscope (TEM), Fourier transform infra-red spectroscopy (FTIR), Thermogravimetric analysis (TGA), X-ray diffraction (XRD), and BET were utilized for the purpose of examining the structural characteristics of obtained adsorbent. Parameters affecting the removal of RR 198 such as pH, the amount of adsorbent, and contact time were investigated at various temperatures and were also optimized. The obtained optimized condition is as follows: pH = 2, time = 60 min and adsorbent dose = 1 g/l. Moreover, a predictive model based on ANFIS for predicting the adsorption amount according to the input variables is presented. The presented model can be used for predicting the adsorption rate based on the input variables include temperature, pH, time, dosage, concentration. The error between actual and approximated output confirm the high accuracy of the proposed model in the prediction process. This fact results in cost reduction because prediction can be done without resorting to costly experimental efforts. SBA-15, CTAB, Reactive Red 198, adsorption study, Adaptive Neuro-Fuzzy Inference systems (ANFIS).
Fiber optic pH sensor with self-assembled polymer multilayer nanocoatings.
Shao, Li-Yang; Yin, Ming-Jie; Tam, Hwa-Yaw; Albert, Jacques
2013-01-24
A fiber-optic pH sensor based on a tilted fiber Bragg grating (TFBG) with electrostatic self-assembly multilayer sensing film is presented. The pH sensitive polymeric film, poly(diallyldimethylammonium chloride) (PDDA) and poly(acrylic acid) (PAA) was deposited on the circumference of the TFBG with the layer-by-layer (LbL) electrostatic self-assembly technique. The PDDA/PAA film exhibits a reduction in refractive index by swelling in different pH solutions. This effect results in wavelength shifts and transmission changes in the spectrum of the TFBG. The peak amplitude of the dominant spectral fringes over a certain window of the transmission spectrum, obtained by FFT analysis, has a near-linear pH sensitivity of 117 arbitrary unit (a.u.)/pH unit and an accuracy of ±1 a.u. (in the range of pH 4.66 to pH 6.02). The thickness and surface morphology of the sensing multilayer film were characterized to investigate their effects on the sensor's performance. The dynamic response of the sensor also has been studied (10 s rise time and 18 s fall time for a sensor with six bilayers of PDDA/PAA).
Biosorption of toxic lead (II) ions using tomato waste (Solanum lycopersicum) activated by NaOH
NASA Astrophysics Data System (ADS)
Permatasari, Diah; Heraldy, Eddy; Lestari, Witri Wahyu
2016-02-01
This research present to uptake lead (II) ion from aqueous solutions by activated tomato waste. Biosorbent were characterized by applying Fourier Transform Infrared Spectroscopy (FTIR) and Surface Area Analyzer (SAA). The biosorption investigated with parameters including the concentration of NaOH, effects of solution pH, biosorbent dosage, contact time,and initial metal concentration. Experimental data were analyzed in terms of two kinetic model such us the pseudo-first order and pseudo-second order. Langmuir and Freundlich isotherm models were applied todescribe the biosorption process. According to the experiment, the optimum concentration of NaOH was achieved at 0.1 M. The maximum % lead (II) removal was achieved at pH 4 with 94.5%. Optimum biosorbentdosage were found as 0.1 g/25 mL solution while optimum contact time were found at 75 minutes. The results showed that the biosorption processes of Lead (II) followed pseudo-second order kinetics. Langmuir adsorption isotherm was found fit the adsorption data with amaximum capacity of 24.079 mg/g with anadsorption energy of 28.046 kJ/mol.
NASA Astrophysics Data System (ADS)
Yusmaniar, Purwanto, Agung; Putri, Elfriyana Awalita; Rosyidah, Dzakiyyatur
2017-03-01
Silica gel modified by 3-aminopropyltriethoxysilane (APTES) was synthesized from rice husk ash combined with activated carbon from coconut shell yielded the composite adsorbent. The composite was characterized by Fourier Transform Infra Red spectroscopy (FT-IR), Electron Dispersive X-Ray (EDX), Surface Area Analyzer (SAA) and adsorption test by Atomic Absorption Spectrometry (AAS). This composite adsorbent has been used moderately for the removal of lead ions from metal solutions and compared with silica gel modified APTES and activated carbon. The adsorption experiments of Pb -ions by adsorbents were performed at different pH and contact time with the same metal solutions concentration, volume solution, and adsorbent dosage. The optimum pH for the adsorption was found to be 5.0 and the equilibrium was achieved for Pb with 20 min of contact time. Pb ions adsorption by composite silica gel modified APTES-activated carbon followed by Langmuir isotherm model with qmax value of 46.9483 mg/g that proved an adsorbent mechanism consistent to the mechanism of monolayer formation.
NASA Astrophysics Data System (ADS)
Mabood, Fazal; Hussain, Z.; Haq, H.; Arian, M. B.; Boqué, R.; Khan, K. M.; Hussain, K.; Jabeen, F.; Hussain, J.; Ahmed, M.; Alharasi, A.; Naureen, Z.; Hussain, H.; Khan, A.; Perveen, S.
2016-01-01
A new UV-Visible spectroscopic method assisted with microwave for the determination of glucose in pharmaceutical formulations was developed. In this study glucose solutions were oxidized by ammonium molybdate in the presence of microwave energy and reacted with aniline to produce a colored solution. Optimum conditions of the reaction including wavelength, temperature, and pH of the medium and relative concentration ratio of the reactants were investigated. It was found that the optimal wavelength for the reaction is 610 nm, the optimal reaction time is 80 s, the optimal reaction temperature is 160 °C, the optimal reaction pH is 4, and the optimal concentration ratio aniline/ammonium molybdate solution was found to be 1:1. The limits of detection and quantification of the method are 0.82 and 2.75 ppm for glucose solution, respectively. The use of microwaves improved the speed of the method while the use of aniline improved the sensitivity of the method by shifting the wavelength.
Interactions of Hydrazine and of Hydrazine Derivatives with Soil Constituents and with Soils.
1982-01-31
exchangeable metal cations held by the clay and humic colloids, or the metal of the hydrous oxide colloids. The pH values of the natural soil solution of most...hydrazine into a soil system will tend to increase the pH of the soil solution . Hydrous oxides of iron and aluminium are insoluble at high pH, and these...aeration, and by the soil solution pH. Treatment of contaminated soils can alter these properties in order to promote the degradation or immobilization of
A study of Reactive Red 198 adsorption on iron filings from aqueous solutions.
Azhdarpoor, Abooalfazl; Nikmanesh, Roya; Khademi, Fahime
2014-01-01
In recent years, reactive dyes have been widely used in textile industries with particular efficiency. They dyes are often toxic, carcinogenic and mutagenic. Improper treatment and non-scientific disposal of dyed wastewater from these industries into water sources has created many environmental problems and concerns around the world. The purpose of the present study is to investigate the efficiency of iron filings in adsorption of Reactive Red 198 from aqueous solutions. This study was conducted using an experimental method at the laboratory scale. In this study, the effects of operating parameters such as pH (1-11), initial dye concentration (40-400 mg/L), contact time (5-120 min) and iron dose (0.1-1 g) with a mesh of<100 were studied. Dye concentration was determined using a spectrophotometer at a wavelength of 520 nm. The results indicated that maximum adsorption capacity of the dye in question was obtained at pH 3, contact time of 60 min and adsorbent dose of 1 g. At initial dye concentration of 100 and 200 mg/L, by increasing the dose of waste iron from 0.1 to 1 g, the removal percentage increased from approximately 76.89% to 97.28% and from 22.64% to 68.03%, respectively. At pH 3, contact time of 5 min and constant waste iron dose of 0.8 g, the dye removal efficiency was 85.34%. By increasing the contact time to 120 min, the removal efficiency increased to 99.2%. Welding iron waste as an inexpensive and available adsorbent has an optimum ability for adsorption of Reactive Red 198 from aqueous solutions.
Khataee, A R; Vatanpour, V; Amani Ghadim, A R
2009-01-30
This study makes a comparison between UV/Nano-TiO(2), Fenton, Fenton-like, electro-Fenton (EF) and electrocoagulation (EC) treatment methods to investigate the removal of C.I. Acid Blue 9 (AB9), which was chosen as the model organic contaminant. Results indicated that the decolorization efficiency was in order of Fenton>EC>UV/Nano-TiO(2)>Fenton-like>EF. Desired concentrations of Fe(2+) and H(2)O(2) for the abatement of AB9 in the Fenton-based processes were found to be 10(-4)M and 2 x 10(-3) M, respectively. In the case of UV/Nano-TiO(2) process, we have studied the influence of the basic photocatalytic parameters such as the irradiation time, pH of the solution and amount of TiO(2) nanoparticles on the photocatalytic decolorization efficiency of AB9. Accordingly, it could be stated that the complete removal of color, after selecting desired operational parameters could be achieved in a relatively short time, about 25 min. Our results also revealed that the most effective decomposition of AB9 was observed with 150 mg/l of TiO(2) nanoparticles in acidic condition. The effect of operational parameters including current density, initial pH and time of electrolysis were studied in electrocoagulation process. The results indicated that for a solution of 20 mg/l AB9, almost 98% color were removed, when the pH was about 6, the time of electrolysis was 8 min and the current density was approximately 25 A/m(2) in electrocoagulation process.
Photo-induced degradation of some flavins in aqueous solution
NASA Astrophysics Data System (ADS)
Holzer, W.; Shirdel, J.; Zirak, P.; Penzkofer, A.; Hegemann, P.; Deutzmann, R.; Hochmuth, E.
2005-01-01
The blue-light induced photo-degradation of FMN, FAD, riboflavin, lumiflavin, and lumichrome in aqueous solution at pH 8 is studied by measurement of absorption coefficient spectral changes due to continuous excitation at 428 nm. The quantum yields of photo-degradation determined are ϕD(riboflavin, pH 8) ≈ 7.8 × 10 -3, ϕD(FMN, pH 5.6) ≈ 7.3 × 10 -3, ϕD(FMN, pH 8) ≈ 4.6 × 10 -3, ϕD(FAD, pH 8) ≈ 3.7 × 10 -4, ϕD(lumichrome, pH 8) ≈ 1.8 × 10 -4, and ϕD(lumiflavin, pH 8) ⩽ 1.1 × 10 -5. In a mass-spectroscopic analysis, the photo-products of FMN dissolved in water (solution pH is 5.6) were identified to be lumichrome and the lumiflavin derivatives dihydroxymethyllumiflavin, formyllumiflavin, and lumiflavin-hydroxy-acetaldehyde. An absorption and emission spectroscopic characterisation of the primary photoproducts of FMN at pH 8 is carried out.
A New Neutral-pH Low-GDP Peritoneal Dialysis Fluid
Himmele, Rainer; Jensen, Lynn; Fenn, Dominik; Ho, Chih-Hu; Sawin, Dixie-Ann; Diaz-Buxo, Jose A.
2012-01-01
♦ Background: Conventional peritoneal dialysis fluids (PDFs) consist of ready-to-use solutions with an acidic pH. Sterilization of these fluids is known to generate high levels of glucose degradation products (GDPs). Although several neutral-pH, low-GDP PD solutions have been developed, none are commercially available in the United States. We analyzed pH and GDPs in Delflex Neutral pH (Fresenius Medical Care North America, Waltham, MA, USA), the first neutral-pH PDF to be approved by the US Food and Drug Administration. ♦ Methods: We evaluated whether patients (n = 26; age range: 18 - 78 years) could properly mix the Delflex Neutral pH PDF after standardized initial training. We further analyzed the concentrations of 10 different glucose degradation products in Delflex Neutral pH PDF and compared the results with similar analyses in other commercially available biocompatible PDFs. ♦ Results: All pH measurements (n = 288) in the delivered Delflex Neutral pH solution consistently fell within the labeled range of 7.0 ± 0.4. Analysis of mixing errors showed no significant impact on the pH results. Delflex Neutral pH, Balance (Fresenius Medical Care, Bad Homburg, Germany), BicaVera (Fresenius Medical Care), and Gambrosol Trio (Gambro Lundia AB, Lund, Sweden) exhibited similar low total GDP concentrations, with maximums in the 4.25% solutions of 88 μmol/L, 74 μmol/L, 74 μmol/L, and 79 μmol/L respectively; the concentration in Physioneal (Baxter Healthcare Corporation, Deerfield, IL, USA) was considerably higher at 263.26 μmol/L. The total GDP concentration in Extraneal (Baxter Healthcare Corporation) was 63 μmol/L, being thus slightly lower than the concentrations in the 4.25% glucose solutions, but higher than the concentrations in the 1.5% and 2.5% glucose solutions. ♦ Conclusions: The new Delflex Neutral pH PDF consistently delivers neutral pH with minimal GDPs. PMID:22383632
2014-01-01
In this work, synthetic nanoscale zerovalent iron (NZVI) stabilized with two polymers, Starch and Carboxymethyl cellulose (CMC) were examined and compared for their ability in removing As (III) and As (V) from aqueous solutions as the most promising iron nanoparticles form for arsenic removal. Batch operations were conducted with different process parameters such as contact time, nanoparticles concentration, initial arsenic concentration and pH. Results revealed that starch stabilized particles (S-nZVI) presented an outstanding ability to remove both arsenate and arsenite and displayed ~ 36.5% greater removal for As (V) and 30% for As (III) in comparison with CMC-stabilized nanoparticles (C-nZVI). However, from the particle stabilization viewpoint, there is a clear trade off to choosing the best stabilized nanoparticles form. Removal efficiency was enhanced with increasing the contact time and iron loading but reduced with increasing initial As (III, V) concentrations and pH. Almost complete removal of arsenic (up to 500 μg/L) was achieved in just 5 min when the S-nZVI mass concentration was 0.3 g/L and initial solution pH of 7 ± 0.1. The maximum removal efficiency of both arsenic species was obtained at pH = 5 ± 0.1 and starched nanoparticles was effective in slightly acidic and natural pH values. The adsorption kinetics fitted well with pseudo-second-order model and the adsorption data obeyed the Langmuir equation with a maximum adsorption capacity of 14 mg/g for arsenic (V), and 12.2 mg/g for arsenic (III). It could be concluded that starch stabilized Fe0 nanoparticles showed remarkable potential for As (III, V) removal from aqueous solution e.g. contaminated water. PMID:24860660
Saha, Papita Das; Chakraborty, Sagnik; Chowdhury, Shamik
2012-04-01
In this study, batch and fixed-bed column experiments were performed to investigate the biosorption potential of Artocarpus heterophyllus (jackfruit) leaf powder (JLP) to remove crystal violet (CV) from aqueous solutions. Batch biosorption studies were carried out as a function of solution pH, contact time, initial dye concentration and temperature. The biosorption equilibrium data showed excellent fit to the Langmuir isotherm model with maximum monolayer biosorption capacity of 43.39 mg g(-1) at pH 7.0, initial dye concentration=50 mg L(-1), temperature=293 K and contact time=120 min. According to Dubinin-Radushkevich (D-R) isotherm model, biosorption of CV by JLP was chemisorption. The biosorption kinetics followed the pseudo-second-order kinetic model. Thermodynamic analysis revealed that biosorption of CV from aqueous solution by JLP was a spontaneous and exothermic process. In order to ascertain the practical applicability of the biosorbent, fixed-bed column studies were also performed. The breakthrough time increased with increasing bed height and decreased with increasing flow rate. The Thomas model as well as the BDST model showed good agreement with the experimental results at all the process parameters studied. It can be concluded that JLP is a promising biosorbent for removal of CV from aqueous solutions. Copyright © 2011 Elsevier B.V. All rights reserved.
Optimizing acidified bleach solutions to improve sporicidal efficacy on building materials.
Wood, J P; Calfee, M W; Clayton, M; Griffin-Gatchalian, N; Touati, A
2011-12-01
We evaluated whether lowering pH (with acetic acid) and raising free available chlorine (FAC) levels in bleach solutions would improve efficacy in inactivating Bacillus spores on different materials. We also determined how varying pH and FAC levels affected bleach stability. Acidified bleach solutions with pH levels of 4.5, 6 and 7.5 and FAC levels between 5000 and 10,000 ppm were evaluated for decontamination efficacy against Bacillus subtilis spores inoculated onto test coupons made from wood, ceramic and galvanized steel. Lowering the pH or increasing the FAC level improved efficacy in some of the tests, but depended on the material, which significantly affected decontamination efficacy. The acidified bleach at pH of 7.5 was significantly less effective than bleach at a pH of 4.5 or 6. The FAC levels in the bleach were the most stable at pH 4.5, and stability at pH 4.5 was not significantly affected by the initial FAC level. It may be advisable to use bleach solutions with lower pH (rather than high FAC levels) in light of both the decontamination efficacy and bleach stability results. For wood materials, use of sporicides other than acidified bleach may be warranted. These results may be useful in preparing acidified bleach solutions for decontamination of materials contaminated with spores such as Bacillus anthracis. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Moriyama, Brad; Henning, Stacey A.; Jin, Haksong; Kolf, Mike; Rehak, Nadja N.; Danner, Robert L.; Walsh, Thomas J.; Grimes, George J.
2011-01-01
PURPOSE To assess the physical compatibility of magnesium sulfate and sodium bicarbonate in a pharmacy-compounded bicarbonate-buffered hemofiltration solution used at the National Institutes of Health Clinical Center (http://www.cc.nih.gov). METHODS Two hemofiltration fluid formulations with a bicarbonate of 50 mEq/L and a magnesium of 1.5 mEq/L or 15 mEq/L were prepared in triplicate with an automated compounding device. The hemofiltration solution with a bicarbonate of 50 mEq/L and a magnesium of 1.5 mEq/L contains the maximum concentration of additives that we use in clinical practice. The hemofiltration solution of 15 mEq/L of magnesium and 50 mEq/L of bicarbonate was used to study the physicochemical properties of this interaction. The solutions were stored without light protection at 22 to 25 °C for 48 hours. Physical compatibility was assessed by visual inspection and microscopy. The pH of the solutions was assayed at 3 to 4 hours and 52 to 53 hours after compounding. In addition, electrolyte and glucose concentrations in the solutions were assayed at two time points after preparation: 3 to 4 hours and 50 to 51 hours. RESULTS No particulate matter was observed by visual and microscopic inspection in the compounded hemofiltration solutions at 48 hours. Electrolyte and glucose concentrations and pH were similar at both time points after solution preparation. CONCLUSION Magnesium sulfate (1.5 mEq/L) and sodium bicarbonate (50 mEq/L) were physically compatible in a pharmacy-compounded bicarbonate-buffered hemofiltration solution at room temperature without light protection at 48 hours. PMID:20237384
Effects of pH values of hydrogen peroxide bleaching agents on enamel surface properties.
Xu, B; Li, Q; Wang, Y
2011-01-01
This study investigated the influence of pH values of bleaching agents on the properties of the enamel surface. Sixty freshly extracted premolars were embedded in epoxy resin and mesiodistally sectioned through the buccal aspect into two parts. The sectioned slabs were distributed among six groups (n=10) and treated using different solutions. Group HCl was treated with HCl solution (pH=3.0) and served as a positive control. Group DW, stored in distilled water (pH=7.0), served as a negative control. Four treatment groups were treated using 30% hydrogen peroxide solutions with different pH values: group HP3 (pH=3.0), group HP5 (pH=5.0), group HP7 (pH=7.0), and group HP8 (pH=8.0). The buccal slabs were subjected to spectrophotometric evaluations. Scanning electron microscopy investigation and Micro-Raman spectroscopy were used to evaluate enamel surface morphological and chemical composition alterations. pH value has a significant influence on the color changes after bleaching (p<0.001). Tukey's multiple comparisons revealed that the order of color changes was HP8, HP7>HP5, HP3>HCl>DW. No obvious morphological alterations were detected on the enamel surface in groups DW, HP7, and HP8. The enamel surface of groups HCl and HP3 showed significant alterations with an erosion appearance. No obvious chemical composition changes were detected with respect to Micro-Raman analysis. Within the limitations of this study, it was concluded that no obvious morphological or chemical composition alterations of enamel surface were detected in the neutral or alkaline bleaching solutions. Bleaching solutions with lower pH values could result in more significant erosion of enamel, which represented a slight whitening effect.
NASA Astrophysics Data System (ADS)
Padhi, S.; Tokunaga, T.
2017-12-01
Adsorption of fluoride (F) on soil can control the mobility of F and subsequent contamination of groundwater. Hence, accurate evaluation of adsorption equilibrium is a prerequisite for understanding transport and fate of F in the subsurface. While there have been studies for the adsorption behavior of F with respect to single mineral constituents based on surface complexation models (SCM), F adsorption to natural soil in the presence of complexing agents needs much investigation. We evaluated the adsorption processes of F on a natural granitic soil from Tsukuba, Japan, as a function of initial F concentration, ionic strength, and initial pH. A SCM was developed to model F adsorption behavior. Four possible surface complexation reactions were postulated with and without including dissolved aluminum (Al) and Al-F complex sorption. Decrease in F adsorption with the increase in initial pH was observed in between the initial pH range of 4 to 9, and a decrease in the rate of the reduction of adsorbed F with respect to the increase in the initial pH was observed in the initial pH range of 5 to 7. Ionic strength variation in the range of 0 to 100mM had insignificant effect on F removal. Changes in solution pH were observed by comparing the solution before and after F adsorption experiments. At acidic pH, the solution pH increased, whereas at alkaline pH, the solution pH decreased after equilibrium. The SCM including dissolved Al and the adsorption of Al-F complex can simulate the experimental results quite successfully. Also, including dissolved Al and the adsorption of Al-F complex to the model explained the change in solution pH after F adsorption.
Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.
Khan, Md Rajibur Rahaman; Kang, Shin-Won
2016-11-09
In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.
Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique
Khan, Md. Rajibur Rahaman; Kang, Shin-Won
2016-01-01
In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors. PMID:27834865
On the asymmetric adsorption of phenylalanine enantiomers by kaolin.
NASA Technical Reports Server (NTRS)
Bonner, W. A.; Flores, J.
1973-01-01
The attempt is described to verify a recent report that kaolin adsorbs D- and L-phenylalanine enantiomers to different extents from aqueous solutions at both pH 5.8 and pH 2. No evidence whatsoever could be found for the differential adsorption of D- versus L-phenylalanine by kaolin from either pH 6 or pH 2 solutions.
New recommendations for measuring collagen solubility.
Latorre, María E; Lifschitz, Adrian L; Purslow, Peter P
2016-08-01
The heat-solubility of intramuscular collagen is usually conducted in 1/4 Ringer's solution at pH7.4, despite this ionic strength and pH being inappropriate for post-rigor meat. The current work studied the percentage of soluble collagen and hydrothermal isometric tension characteristics of perimysial strips on bovine semitendinosus muscles in either 1/4 Ringer's solution, distilled water, PBS, or a solution of the same salt concentration as 1/4 Ringer's but at pH5.6. Values of % soluble collagen were lower at pH7.4 than 5.6. Increasing ionic strength reduced % soluble collagen. The maximum perimysial isometric tension was independent of the bathing medium, but the percent relaxation was higher at pH7.4 than at pH5.6, and increased with ionic strength of the media. It is recommended that future measurements of collagen solubility and tests on connective tissue components of post-rigor meat should be carried out in a solution of concentrations NaCl and KCl equivalent to those in 1/4 Ringer's, but at pH5.6, a pH relevant to post-rigor meat. Copyright © 2016 Elsevier Ltd. All rights reserved.
Nguyen, Truong X; Kattnig, Daniel; Mansha, Asim; Grampp, Günter; Yurkovskaya, Alexandra V; Lukzen, Nikita
2012-11-08
The kinetics of triplet state quenching of 3,3',4,4'-benzophenone tetracarboxylic acid (BPTC) by DNA bases adenine, adenosine, thymine, and thymidine has been investigated in aqueous solution using time-resolved laser flash photolysis. The observation of the BPTC ketyl radical anion at λ(max) = 630 nm indicates that one electron transfer is involved in the quenching reactions. The pH-dependence of the quenching rate constants is measured in detail. As a result, the chemical reactivity of the reactants is assigned. The bimolecular rate constants of the quenching reactions between triplet BPTC and adenine, adenosine, thymine, and thymidine are k(q) = 2.3 × 10(9) (4.7 < pH < 9.9), k(q) = 4.0 × 10(9) (3.5 < pH < 4.7), k(q) = 1.0 × 10(9) (4.7 < pH < 9.9), and k(q) = 4.0 × 10(8) M(-1) s(-1) (4.7 < pH < 9.8), respectively. Moreover, it reveals that in strong basic medium (pH = 12.0) a keto-enol tautomerism of thymine inhibits its reaction with triplet BPTC. Such a behavior is not possible for thymidine because of its deoxyribose group. In addition, the pH-dependence of the apparent electrochemical standard potential of thymine in aqueous solution was investigated by cyclic voltammetry. The ΔE/ΔpH ≈ -59 mV/pH result is characteristic of proton-coupled electron transfer. This behavior, together with the kinetic analysis, leads to the conclusion that the quenching reactions between triplet BPTC and thymine involve one proton-coupled electron transfer.
2012-01-01
The kinetics of triplet state quenching of 3,3′,4,4′-benzophenone tetracarboxylic acid (BPTC) by DNA bases adenine, adenosine, thymine, and thymidine has been investigated in aqueous solution using time-resolved laser flash photolysis. The observation of the BPTC ketyl radical anion at λmax = 630 nm indicates that one electron transfer is involved in the quenching reactions. The pH-dependence of the quenching rate constants is measured in detail. As a result, the chemical reactivity of the reactants is assigned. The bimolecular rate constants of the quenching reactions between triplet BPTC and adenine, adenosine, thymine, and thymidine are kq = 2.3 × 109 (4.7 < pH < 9.9), kq = 4.0 × 109 (3.5 < pH < 4.7), kq = 1.0 × 109 (4.7 < pH < 9.9), and kq = 4.0 × 108 M–1 s–1 (4.7 < pH < 9.8), respectively. Moreover, it reveals that in strong basic medium (pH = 12.0) a keto–enol tautomerism of thymine inhibits its reaction with triplet BPTC. Such a behavior is not possible for thymidine because of its deoxyribose group. In addition, the pH-dependence of the apparent electrochemical standard potential of thymine in aqueous solution was investigated by cyclic voltammetry. The ΔE/ΔpH ≈ −59 mV/pH result is characteristic of proton-coupled electron transfer. This behavior, together with the kinetic analysis, leads to the conclusion that the quenching reactions between triplet BPTC and thymine involve one proton-coupled electron transfer. PMID:23038981
Bai, Bing; Chen, Fang; Wang, Zhengfu; Liao, Xiaojun; Zhao, Guanghua; Hu, Xiaosong
2005-09-07
While green discoloration during garlic processing is of a major concern, this greening is desirable and required for the traditional homemade Chinese "Laba" garlic. To obtain insights into the mechanism of color formation, simulation of the greening of "Laba" garlic was carried out in the laboratory by soaking aged garlic in 5% (v/v, pH 2.33) acetic acid solution. After 2 days, the garlic cloves turned green. Up to 4 days, pigment(s) diffused from garlic cloves to the pickling solution. The solution exhibits two maximal absorbances at approximately 440 and approximately 590 nm, corresponding to yellow and blue species, respectively, the combination of which creates the green coloration. With increasing time from 4 to 25 days, the concentration of both yellow and blue species increases at nearly the same rate, while after 25 days, the concentration of the yellow species increases faster than that of the blue species. Interestingly, most thiosulfinates ( approximately 85%) in garlic cloves were converted within 4 days, suggesting that thiosulfinate conversion is proportional to the formation of the pigments. Consistent with this conclusion, alliinase and acetic acid were required for the color formation. UV-vis spectral measurements and pH results suggest that the color formation occurs by two kinds of processes: one enzymatic and the other nonenzymatic. Low pH (2.0-3.0) favors nonenzymatic reactions, while high pH (6.0 or above) is conducive to enzymatic reactions. Thus, the ideal pH for the entire process of garlic greening is between 4.0 and 5.0, which is a compromise of the optimal pH of both the enzymatic and nonenzymatic reactions.
Basharat, Meer; deSouza, Nandita M.; Parkes, Harold G.
2015-01-01
Purpose To estimate the exchange rates of labile 1H in citrate and spermine, metabolites present in prostatic secretions, to predict the size of the citrate and spermine CEST effects in vivo. Methods CEST z‐spectra were acquired at high‐field [11.7 Tesla (T)] from citrate and spermine solutions at physiological pH (6.5) using saturation power 6 μT. CEST was performed at different temperatures to determine exchange regimes (slow, intermediate or fast). For low pH solutions of spermine, exchange rates were estimated from resonance line width, fitting z‐spectra using the Bloch equations incorporating exchange, and using quantifying exchange using saturation time experiments (QUEST). These rates were extrapolated to physiological pH. Results Citrate showed little CEST effect at pH 6.5 and temperature (T) = 310 K (maximum 0.001% mM‐1), indicating fast exchange, whereas spermine showed greater CEST effects (maximum 0.2% mM‐1) indicating intermediate‐to‐fast exchange. Extrapolating data acquired from low pH spermine solutions predicts exchange rates at pH 6.5 and T of 310 K of at least 2 × 104s‐1. Conclusion Citrate and spermine show minimal CEST effects at 11.7T even using high saturation power. These effects would be much less than 2% at clinical field‐strengths due to relatively faster exchange and would be masked by CEST from proteins. Magn Reson Med 76:742–746, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:26467055
PLA/CS/Nifedipine Nanocomposite Films: Properties and the In Vitro Release of Nifedipine
NASA Astrophysics Data System (ADS)
Trang, Nguyen Thi Thu; Chinh, Nguyen Thuy; Giang, Nguyen Vu; Thanh, Dinh Thi Mai; Lam, Tran Dai; Hoang, Thai
2016-07-01
The polylactic acid (PLA)/chitosan (CS) films containing a drug, nifedipine (NIF), in the presence of polyethylene oxide (PEO) as a compatibilizer were prepared by the solution method. This method has not been used to form films containing four components (PLA, CS, NIF, PEO) up to now. The CS, PEO, and NIF contents are 25 wt.%, 6-8 wt.%, and 10-50 wt.% in comparison with PLA weight, respectively. Fourier transform infrared spectroscopy (FTIR), thermo-gravimetric analysis (TGA), differential scanning calorimetry (DSC), and field emission scanning electron microscopy (FESEM) were used to characterize the interactions, properties, and morphology of the PLA/CS/PEO/NIF films. The FTIR, TGA, and DSC results show that NIF carried by PLA/CS/PEO films and PLA, CS, NIF had better interaction and were more compatible when using PEO. The surface morphology of PLA/CS/PEO/NIF films was similar to that of PLA/CS/PEO films. Moreover, this was the first time drug loading and NIF release content from PLA/CS/PEO films were determined by the ultraviolet-visible (UV-Vis) spectroscopy method. The drug loading of PLA/CS/PEO/NIF films was from 80.99% to 93.61%. The in vitro NIF release studies were carried out in pH 2, 6.8, and 7.4 solutions corresponding to the pH of stomach, colon, and duodenum regions in the human body, respectively. The NIF release content in different pH solutions is in the order: pH 2 > pH 6.8 > pH 7.4 and increases when there is increasing NIF loading. The PLA/CS/PEO films are potential materials to apply for long-circulating systems for NIF delivery.
Long-term leaching of photovoltaic modules
NASA Astrophysics Data System (ADS)
Nover, Jessica; Zapf-Gottwick, Renate; Feifel, Carolin; Koch, Michael; Metzger, Jörg W.; Werner, Jürgen H.
2017-08-01
Some photovoltaic module technologies use toxic materials. We report long-term leaching on photovoltaic module pieces of 5 × 5 cm2 size. The pieces are cut out from modules of the four major commercial photovoltaic technologies: crystalline and amorphous silicon, cadmium telluride as well as from copper indium gallium diselenide. To simulate different environmental conditions, leaching occurs at room temperature in three different water-based solutions with pH 3, 7, and 11. No agitation is performed to simulate more representative field conditions. After 360 days, about 1.4% of lead from crystalline silicon module pieces and 62% of cadmium from cadmium telluride module pieces are leached out in acidic solutions. The leaching depends heavily on the pH and the redox potential of the aqueous solutions and it increases with time. The leaching behavior is predictable by thermodynamic stability considerations. These predictions are in good agreement with the experimental results.
Ghazy, S E; Samra, S E; Mahdy, A F M; El-Morsy, S M
2004-11-01
A simple and economic experimental sorptive -flotation procedure is presented for the removal of copper(II) species from aqueous solutions. It is based on using powdered marble wastes (PMW), which are widespread and inexpensive and may represent an environmental problem, as the effective inorganic sorbent and oleic (HOL) as the surfactant. The main parameters (i.e. initial solution pH, sorbent, surfactant and copper concentrations, stirring times, ionic strength, temperature and the presence of foreign ions) influencing the flotation of PMW and /or Cu(II) were examined. Nearly, 100% of PMW and Cu(II) were removed from aqueous solutions at pH7 after stirring for 10 min and at room temperature, (approximately 25 degrees C). The procedure was successfully applied to recover Cu(II) spiked to some natural water samples. A mechanism for sorption and flotation is suggested.
Huang, Ruihua; Liu, Qian; Zhang, Lujie; Yang, Bingchao
2015-01-01
A kind of biocomposite was prepared by the intercalation of chitosan in bentonite and the cross-linking reaction of chitosan with glutaraldehyde, which was referred to as cross-linked chitosan/bentonite (CCS/BT) composite. Adsorptive removal of methyl orange (MO) from aqueous solutions was investigated by batch method. The adsorption of MO onto CCS/BT composite was affected by the ratio of chitosan to BT and contact time. pH value had only a minor impact on MO adsorption in a wide pH range. Adsorption kinetics was mainly controlled by the pseudo-second-order kinetic model. The adsorption of MO onto CCS/BT composite followed the Langmuir isotherm model, and the maximum adsorption capacity of CCS/BT composite calculated by the Langmuir model was 224.8 mg/g. Experimental results indicated that this adsorbent had a potential for the removal of MO from aqueous solutions.
Adsorptive removal of patulin from aqueous solution using thiourea modified chitosan resin.
Liu, Bingjie; Peng, Xiaoning; Chen, Wei; Li, Yang; Meng, Xianghong; Wang, Dongfeng; Yu, Guangli
2015-09-01
In the present paper, thiourea modified chitosan resin (TMCR) was firstly prepared through converting hydroxyl groups of chitosan resin into thiol groups, using glutaraldehyde as cross-linking agent and thiourea as modification agent. TMCR was characterized by FTIR, EDXS, SEM, XRD and AFM technologies. Batch adsorption experiments were performed to study the adsorption capacity of TMCR for patulin at different pH, temperature, contact time and patulin concentration. The result showed that TMCR was effective in removal of patulin from aqueous solution. The adsorption capacity of TMCR for patulin was 1.0 mg/g at pH 4.0, 25 °C for 24 h. Adsorption process could be well described by pseudo-first order model, Freundlich isotherm model and intraparticle diffusion model. It indicated that TMCR is expected to be a new material for patulin adsorption from aqueous solutions. Copyright © 2015 Elsevier B.V. All rights reserved.
Plasma Discharge with Different Electrode Diameters for Reducing Methylene Blue Concentration
NASA Astrophysics Data System (ADS)
Rasyidah, H.; Kusumandari; Saraswati, T. E.; Anwar, M.
2018-03-01
Recently, plasma technology has gained attention since it overcomes the shortcomings of water treatment. This research studies the effect of electrode diameter of plasma discharge reactors on the concentration reduction of methylene blue as an organic solution. The plasma discharge reactor was built from a pair of stainless needle electrodes connected with high-AC voltage. The electrodes were placed approximately 2 mm above the solution and stirred at 5.5 rpm. The diameters of the electrodes were 2, 3.2 and 4 mm. The times for plasma treatment were set at 2, 4, 6, 8 and 10 min. Absorbance, temperature and pH of the solution were measured to know the effects of electrode diameter of the plasma reactor. Absorbance and pH significantly decreased after plasma treatment. The best of the absorbance reduction were obtained when the sample was treated under plasma discharge using the smallest diameter electrodes for 8-10 min.
NASA Astrophysics Data System (ADS)
Luo, Hong; Su, Huaizhi; Dong, Chaofang; Li, Xiaogang
2017-04-01
In this paper, the passivation and electrochemical behavior of 316L stainless steel in chlorinated simulated concrete pore solutions at different pH was evaluated by potentiodynamic measurements, electrochemical impedance spectroscopy. The composition of the passive film and surface morphology were investigated by X-ray photoelectron spectroscopy (XPS), secondary ion mass spectrometry (SIMS), and scanning electron microscopy, respectively. The results reveal that metastable pitting susceptibility, stable pitting corrosion, and composition of the passive film are influenced by pH value. After long time immersion, a bilayer structure passive film can be formed in this environment. The appearance of molybdates on the outermost surface layer, further enhancing the stability of the passive film. Moreover, the good pitting corrosion resistance of 316L stainless steel in simulated concrete pore solution without carbonated is mainly due to the presence of high Cr/Fe ratio and molybdates ions within the passive film.
Liu, Cong; Zhang, Erlin
2015-03-01
Ti-10Cu sintered alloy has shown strong antibacterial properties against S. aureus and E. coli and good cell biocompatibility, which displays potential application in dental application. The corrosion behaviors of the alloy in five different simulated biological solutions have been investigated by electrochemical technology, surface observation, roughness measurement and immersion test. Five different simulated solutions were chosen to simulate oral condition, oral condition with F(-) ion, human body fluids with different pH values and blood system. It has been shown that Ti-10Cu alloy exhibits high corrosion rate in Saliva pH 3.5 solution and Saliva pH 6.8 + 0.2F solution but low corrosion rate in Hank's, Tyrode's and Saliva pH 6.8 solutions. The corrosion rate of Ti-10Cu alloy was in a order of Hank's, Tyrode's, Saliva pH 6.8, Saliva-pH 3.5 and Saliva pH 6.8 + 0.2F from slow to fast. All results indicated acid and F(-) containing conditions prompt the corrosion reaction of Ti-Cu alloy. It was suggested that the Cu ion release in the biological environments, especially in the acid and F(-) containing condition would lead to high antibacterial properties without any cell toxicity, displaying wide potential application of this alloy.
Chen, Long; He, Linwei; Ma, Fuyin; Liu, Wei; Wang, Yaxing; Silver, Mark A; Chen, Lanhua; Zhu, Lin; Gui, Daxiang; Diwu, Juan; Chai, Zhifang; Wang, Shuao
2018-05-09
Real-time and accurate detection of pH in aqueous solution is of great significance in chemical, environmental, and engineering-related fields. We report here the use of 8-hydroxyquinoline-functionalized covalent organic framework (COF-HQ) for dual-mode pH sensing. In the fluorescent mode, the emission intensity of COF-HQ weakened as the pH decreased, and also displayed a good linear relationship against pH in the range from 1 to 5. In addition, COF-HQ showed discernible color changes from yellow to black as the acidity increased and can be therefore used as a colorimetric pH sensor. All these changes are reversible and COF-HQ can be recycled for multiple detection runs owing to its high hydrolytical stability. It can be further assembled into a mixed matrix membrane for practical applications.
NASA Technical Reports Server (NTRS)
Lupton, J. E.
1972-01-01
An analytic solution was obtained to the complete Fokker-Planck equation for solar flare particle propagation including the effects of convection, energy-change, corotation, and diffusion. It is assumed that the particles are injected impulsively at a single point in space, and that a boundary exists beyond which the particles are free to escape. Several solar flare particle events were observed with solar and galactic cosmic ray experiment aboard OGO 6. Detailed comparisons of the predictions of the solution with observations of 1 to 70 MeV protons show that the model adequately describes both the rise and decay times. The solution also yields a time evolution for the vector anisotropy which agrees well with reported observations.
Water Treatment Using Plasma Discharge with Variation of Electrode Materials
NASA Astrophysics Data System (ADS)
Chanan, N.; Kusumandari; Saraswati, T. E.
2018-03-01
This research studied water treatment using plasma discharge. Plasma generated in this study produced active species that played a role in organic compound decomposition. The plasma reactor consisted of two needle electrodes made from stainless steel, tungsten, aluminium and grafit. It placed approximately 2 mm above the solution and connected with high-AC voltage. A solution of methylene blue used as an organic solution model. Plasma treatment times were 2, 4, 6, 8 and 10 min. The absorbance, temperature and pH of the solution were measured before and after treatment using various electrodes. The best electrode used in plasma discharging for methylene blue absorbance reduction was the graphite electrode, which provided the highest degradation efficiency of 98% at 6 min of treatment time.
Evaluating nanoparticle sensor design for intracellular pH measurements.
Benjaminsen, Rikke V; Sun, Honghao; Henriksen, Jonas R; Christensen, Nynne M; Almdal, Kristoffer; Andresen, Thomas L
2011-07-26
Particle-based nanosensors have over the past decade been designed for optical fluorescent-based ratiometric measurements of pH in living cells. However, quantitative and time-resolved intracellular measurements of pH in endosomes and lysosomes using particle nanosensors are challenging, and there is a need to improve measurement methodology. In the present paper, we have successfully carried out time-resolved pH measurements in endosomes and lyosomes in living cells using nanoparticle sensors and show the importance of sensor choice for successful quantification. We have studied two nanoparticle-based sensor systems that are internalized by endocytosis and elucidated important factors in nanosensor design that should be considered in future development of new sensors. From our experiments it is clear that it is highly important to use sensors that have a broad measurement range, as erroneous quantification of pH is an unfortunate result when measuring pH too close to the limit of the sensitive range of the sensors. Triple-labeled nanosensors with a pH measurement range of 3.2-7.0, which was synthesized by adding two pH-sensitive fluorophores with different pK(a) to each sensor, seem to be a solution to some of the earlier problems found when measuring pH in the endosome-lysosome pathway.
NASA Astrophysics Data System (ADS)
Todoran, R.; Todoran, D.; Anitas, E. M.; Szakács, Zs
2016-08-01
We propose reflectance measurements as a method for the evaluation of the kinetics of adsorption processes, to compute the diffusion times of the adsorption products at the thin layers formed at the sphalerite natural mineral-potassium ethyl xanthate solution interface. The method is based on the intensity measurement of the reflected monochromatic radiation obtained from the mineral-xanthate thin layer as a function of time. These determinations were made at the thin layer formed between the sphalerite or activated sphalerite natural minerals with potassium ethyl xanthate, for different solutions concentrations and pH values at constant temperature. Diffusion times of desorbed molecular species into the liquid bring important information about the global kinetics of the ions in this phase during adsorption processes at interfaces. Analysing the time dependence of this parameter one concluded on the diffusion properties of the xanthate molecule in the solution depending on its concentration and pH, knowing that at the initial time these molecules had a uniform spread. This method enabled us to determine that, in time interval of approximately 35 minutes to achieve dynamic equilibrium in the formation of the interface layer, one had three different kinetic behaviours of our systems. In the first 5-8 min one had highly adsorbent character, the state of equilibrium is followed by low adsorbent properties. Gaining information on the adsorption kinetics in the case of xanthate on mineral surface leads to the optimization of the industrial froth flotation process.
Yang, Zongbo; Cheng, Jun; Li, Ke; Zhou, Junhu; Cen, Kefa
2016-08-01
Up-down chute and oscillating (UCO) baffles were used to generate vortex and oscillating flow field to improve growth rate of Haematococcus pluvialis in a raceway pond. Effects of gas flow rate, solution velocity, and solution depth on solution mass transfer coefficient and mixing time were evaluated using online pH and dissolved oxygen probes. Mass transfer coefficient increased by 1.3 times and mixing time decreased by 33% when UCO baffles were used in the H. pluvialis solution, resulting in an 18% increase in biomass yield with 2% CO2. The H. pluvialis biomass yield further increased to 1.5g/L, and astaxanthin composition accumulated to 29.7mg/L under relatively higher light intensity and salinity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hove, L H; Holme, B; Stenhagen, K R; Tveit, A B
2011-01-01
To evaluate how concentration and pH of TiF(4) influence the erosion-protective effect. Specimens were treated with a TiF(4) solution: (1) 0.5 M F, pH 1.2, (2) 0.05 M F, pH 2.1, (3) 0.5 M F, pH 2.1, or (4) 0.05 M F, pH 1.2; then, they were exposed to HCl. After 2 min, the proportions of the area covered with the coating were 93, 71, 17 and 0% in groups 1-4. When present, the coating seemed to protect the surface. After 6 min, a coating could only be seen in group 1 (43%). Reducing the concentration of TiF(4) and increasing the pH of the solution decreased the protective effect. 2011 S. Karger AG, Basel.
Thermodynamic Solubility Profile of Carbamazepine-Cinnamic Acid Cocrystal at Different pH.
Keramatnia, Fatemeh; Shayanfar, Ali; Jouyban, Abolghasem
2015-08-01
Pharmaceutical cocrystal formation is a direct way to dramatically influence physicochemical properties of drug substances, especially their solubility and dissolution rate. Because of their instability in the solution, thermodynamic solubility of cocrystals could not be determined in the common way like other compounds; therefore, the thermodynamic solubility is calculated through concentration of their components in the eutectic point. The objective of this study is to investigate the effect of an ionizable coformer in cocrystal with a nonionizable drug at different pH. Carbamazepine (CBZ), a nonionizable drug with cinnamic acid (CIN), which is an acidic coformer, was selected to prepare CBZ-CIN cocrystal and its thermodynamic solubility was studied in pH range 2-7. Instead of HPLC that is a costly and time-consuming method, a chemometric-based approach, net analyte signal standard addition method, was selected for simultaneous determination of CBZ and CIN in solution. The result showed that, as pH increases, CIN ionization leads to change in CBZ-CIN cocrystal solubility and stability in solution. In addition, the results of this study indicated that there is no significant difference between intrinsic solubility of CBZ and cocrystal despite the higher ideal solubility of cocrystal. This verifies that ideal solubility is not good parameter to predict cocrystal solubility. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
NASA Astrophysics Data System (ADS)
Fu, Yingxian
1993-01-01
There is considerable uncertainty about dynamic aspects of the photophysics of the adenylyl chromophore, stemming from the discordant values reported for the room temperature fluorescence lifetimes (tau_1 = 5 ps, tau_2 = 330 ps for 9MeAde; tau_1 = 290 ps, tau_2 = 4.17 ns for ATP). Spectra reported in conjunction with these lifetimes create difficulties in assignment of emission. To clarify this situation I have investigated the fluorescence decay times and time -resolved emission spectra of adenylyl compounds under a variety of conditions (concentration, pH, solvent) using sub-ns laser excitation at 265 nm together with gated fast sampling (100 ps) detection and signal averaging. Multi -component decays and spectra are observed in aqueous solution. Major slow components (tau = 4.4 +/- 0.2 ns) with emission maxima at 380 nm are found for all components at pH 1.1 and for ATP at pH 4.4. At pH 7 a fast component (<100 ps) predominates. There is no marked evidence for a concentration dependence, the oscillator strengths are 10^ {-3}-10^{-5} and transitions must be classified as weakly forbidden. Single component emission is observed in acetonitrile and ethanol. The UV absorption spectra of biomolecules d(CG) and polyd(GC)cdotpolyd(GC) exhibit the different hypochromic effects due to different interactions between guanosine(G) and cytidine(C) in stacked form. The present work has been carried out to explain this quantitatively. To approach this problem the absorption spectra of G and C have been resolved into gaussian components using the PeakFit program. The absorption spectra (220-310 nm) of d(CG) and polyd(GC)cdotpolyd(GC) have been fitted with gaussian components of G and C (in the order of increasing energy, G1 and G2, and C1, C2 and C3, respectively), and the contribution to both spectra from individual gaussians is estimated in terms of oscillator strengths. The fitting results suggest that the small hypochromism in absorption spectrum of d(CG) may be attributed to the interactions between G1 and C1; the large hypochromism in absorption spectrum of polyd(GC)cdotpolyd(GC) probably originates from the interactions between G1, C1, C2 and C3. The present work has also resolved a series of absorption spectra of cytidyl chromophore in different pH aqueous solution and various solvents. Time-resolved emission spectra of GMP, dCMP and m^5 -dCMP in different pH aqueous solutions have been determined. The results show that pH affects the lifetimes and spectral characteristics of GMP significantly, but does not affect dCMP and m^5-dCMP.
Wang, Tongxin; Cölfen, Helmut
2006-10-10
Simple solution analysis of the formation mechanism of complex BaSO(4) fiber bundles in the presence of polyacrylate sodium salt, via a bioinspired approach, is reported. Titration of the polyacrylate solution with Ba(2+) revealed complex formation and the optimum ratio of Ba(2+) to polyacrylate for a slow polymer-controlled mineralization process. This is a much simpler and faster method to determine the appropriate additive/mineral concentration pairs as opposed to more common crystallization experiments in which the additive/mineral concentration is varied. Time-dependent pH measurements were carried out to determine the concentration of solution species from which BaSO(4) supersaturation throughout the fiber formation process can be calculated and the second-order kinetics of the Ba(2+) concentration in solution can be identified. Conductivity measurements, pH measurements, and analytical ultracentrifugation revealed the first formed species to be Ba-polyacrylate complexes. A combination of the solution analysis results and optical microscopic images allows a detailed picture of the complex precipitation and self-organization process, a particle-mediated process involving mesoscopic transformations, to be revealed.
Chamkouri, Narges; Niazi, Ali; Zare-Shahabadi, Vali
2016-03-05
A novel pH optical sensor was prepared by immobilizing an azo dye called Janus Green B on the triacetylcellulose membrane. Condition of the dye solution used in the immobilization step, including concentration of the dye, pH, and duration were considered and optimized using the Box-Behnken design. The proposed sensor showed good behavior and precision (RSD<5%) in the pH range of 2.0-10.0. Advantages of this optical sensor include on-line applicability, no leakage, long-term stability (more than 6 months), fast response time (less than 1 min), high selectivity and sensitivity as well as good reversibility and reproducibility. Copyright © 2015. Published by Elsevier B.V.
Method for removing metals from a cleaning solution
Deacon, Lewis E.
2002-01-01
A method for removing accumulated metals from a cleaning solution is provided. After removal of the metals, the cleaning solution can be discharged or recycled. The process manipulates the pH levels of the solution as a means of precipitating solids. Preferably a dual phase separation at two different pH levels is utilized.
Solubility of glucose isomerase in ammonium sulphate solutions
NASA Astrophysics Data System (ADS)
Chayen, N.; Akins, J.; Campbell-Smith, S.; Blow, D. M.
1988-07-01
In order to quantify protein crystallization techniques, a method for measuring protein solubility in high salt concentration has been developed. It is based on a sensitive protein concentration assay, using binding to Coomassie blue dye. The protein concentration in a supernatant from which glucose isomerase is crystallising has been studied as a function of time. Equilibrium is established in 3-5 weeks, and the protein concentration remaining in solution is defined as the solubility of the protein. The solubility of glucose isomerase has been determined as a function of ammonium sulphate concentration; its variation with pH in 1.50M ammonium sulphate has also been studied. A remarkable dependence on pH over the range of 5.5 to 6.5 has been observed.
Stability studies of lincomycin hydrochloride in aqueous solution and intravenous infusion fluids.
Czarniak, Petra; Boddy, Michael; Sunderland, Bruce; Hughes, Jeff D
2016-01-01
The purpose of this study was to evaluate the chemical stability of Lincocin(®) (lincomycin hydrochloride) in commonly used intravenous fluids at room temperature (25°C), at accelerated-degradation temperatures and in selected buffer solutions. The stability of Lincocin(®) injection (containing lincomycin 600 mg/2 mL as the hydrochloride) stored at 25°C±0.1°C in sodium lactate (Hartmann's), 0.9% sodium chloride, 5% glucose, and 10% glucose solutions was investigated over 31 days. Forced degradation of Lincocin(®) in hydrochloric acid, sodium hydroxide, and hydrogen peroxide was performed at 60°C. The effect of pH on the degradation rate of lincomycin hydrochloride stored at 80°C was determined. Lincomycin hydrochloride w as found to maintain its shelf life at 25°C in sodium lactate (Hartmann's) solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution, with less than 5% lincomycin degradation occurring in all intravenous solutions over a 31-day period. Lincomycin hydrochloride showed less rapid degradation at 60°C in acid than in basic solution, but degraded rapidly in hydrogen peroxide. At all pH values tested, lincomycin followed first-order kinetics. It had the greatest stability near pH 4 when stored at 80°C (calculated shelf life of 4.59 days), and was least stable at pH 2 (calculated shelf life of 0.38 days). Lincocin(®) injection was chemically found to have a shelf life of at least 31 days at 25°C when added to sodium lactate (Hartmann's) solution, 0.9% sodium chloride solution, 5% glucose solution, and 10% glucose solution. Solutions prepared at approximately pH 4 are likely to have optimum stability.
The VCD pattern of the ν(C=O) bands in isoindolinones.
Rode, Joanna Ewa; Lyczko, Krzysztof; Jawiczuk, Magdalena; Kawęcki, Robert; Stańczyk, Wojciech; Jaglińska, Agnieszka; Dobrowolski, Jan Cz
2018-05-18
The IR and VCD spectra of both enantiomers of Me, iPr, nBu, Ph and CH2Ph substituted isoindolinones in solution and KBr pellets were measured and interpreted with DFT calculations. The spectra in solution revealed no important differences in the C=O stretching vibration region while the interpretation of very distinct spectra taken in pellets required determining the crystal structures. The studied compounds crystallized in the P212121 (Me, iPr, CH2Ph), P31 (nBu), and P21 (Ph) space groups. We found that the quality of simulated spectra strongly depends on the substituent, the structure of the molecular cluster assumed, basis set, and use of the dispersion correction. The IR spectra can be reproduced well based on the simplest linear arrangement of hydrogen-bonded chains mimicking the molecular arrangement in the crystals. We found no common approach to reproduce all the registered VCD spectra in the crystal phase. For the Me and nBu isoindolinones, the VCD pattern was the best reproduced by full optimization of the selected large molecular clusters. For iPr, Ph and CH2Ph derivatives optimizing only the position of H-atoms in a fragment frozen as in the crystal provides the best results. Such an approach can reduce the computation time from months to one week. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lin, YuPo J.; Hestekin, Jamie; Arora, Michelle; St. Martin, Edward J.
2004-09-28
An electrodeionization method for continuously producing and or separating and/or concentrating ionizable organics present in dilute concentrations in an ionic solution while controlling the pH to within one to one-half pH unit method for continuously producing and or separating and/or concentrating ionizable organics present in dilute concentrations in an ionic solution while controlling the pH to within one to one-half pH unit.
Topley, N; Kaur, D; Petersen, M M; Jörres, A; Williams, J D; Faict, D; Holmes, C J
1996-02-01
The inclusion of bicarbonate in the formulation of peritoneal dialysis solutions may avoid the in vitro impairment of certain cell functions seen with acidic lactate-based fluids. The supranormal physiological levels of HCO3- and PCO2 inherent in such formulations may, however, not be biocompatible. This study compared the in vitro biocompatibility of a pH 5.2 lactate-based formulation with formulations containing either 40 mM lactate at pH 7.4, 38 mM HCO3- at pH 6.8 (PCO2 at approximately 240 mm Hg) or 7.4 (PCO2 at approximately 60 mm Hg), and 25 mM HCO3- plus 15 mM lactate at pH 6.8 (PCO2 at approximately 160 mm Hg) or 7.4 (PCO2 at approximately 40 mm Hg). Significant release of lactate dehydrogenase or decreases in ATP content by human peritoneal mesothelial cells (HPMC) and human peripheral polymorphonuclear leukocytes (PMN) after a 30-min exposure to each test solution was only seen with the pH 5.2 lactate-based fluid. The ATP content of HPMC exposed to this fluid returned to control levels after 30 min of recovery in M199 control medium but showed a trend toward decreasing ATP content at 240 min. Similarly, interleukin (IL)-1 beta-induced IL-6 synthesis by HPMC was also only significantly reduced by the pH 5.2 lactate solution. PMN chemiluminescence was unaffected by 30-min exposure to all test solutions except for the pH 5.2 lactate formulation. Staphylococcus epidermidis phagocytosis was reduced to between 46 to 57% of control with all test solutions except the pH 5.2 lactate solution, which further suppressed the chemiluminescence response to 17% of control. These data suggest that short exposure to supranormal physiological levels of HCO3- and PCO2 does not impair HPMC or PMN viability and function. Furthermore, neutral pH lactate-containing solutions show equivalent biocompatibility to bicarbonate-based ones.
NASA Astrophysics Data System (ADS)
Zirino, Albert
1994-08-01
A transparent polyelectrolyte fiber or gel, such as crosslinked polyacrylic acid, which contracts and expands upon the addition of an acid or base to an aqueous medium solution, is placed in the same solution with a pH dependent dye, a colored photochromatic indicator dye. The dye preferably has a pAa value that is the same as the pH at a null contraction point of the fiber. By irradiating the solution with light of a wavelength of the absorption band of either the acid or base form of the dye, the solution pH is made to change, and the fiber is made to expand or contract, depending upon the wavelength. Thus, light energy is readily converted to work energy and may be used to power a pump, for example or an artificial muscle can be powered via an optical fiber.
Avila Ruiz, Geraldine; Xi, Bingyan; Minor, Marcel; Sala, Guido; van Boekel, Martinus; Fogliano, Vincenzo; Stieger, Markus
2016-09-28
The aim of the study was to determine the influence of pressure in high-pressure-high-temperature (HPHT) processing on Maillard reactions and protein aggregation of whey protein-sugar solutions. Solutions of whey protein isolate containing either glucose or trehalose at pH 6, 7, and 9 were treated by HPHT processing or conventional high-temperature (HT) treatments. Browning was reduced, and early and advanced Maillard reactions were retarded under HPHT processing at all pH values compared to HT treatment. HPHT induced a larger pH drop than HT treatments, especially at pH 9, which was not associated with Maillard reactions. After HPHT processing at pH 7, protein aggregation and viscosity of whey protein isolate-glucose/trehalose solutions remained unchanged. It was concluded that HPHT processing can potentially improve the quality of protein-sugar-containing foods, for which browning and high viscosities are undesired, such as high-protein beverages.
Effect of pH of spray solution on the electrical properties of cadmium oxide thin films
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodlur, R. M.; Gunnagol, Raghu M.; Rabinal, M. K., E-mail: mkrabinal@yahoo.com
2015-06-24
Highly conducting transparent cadmium oxide thin films were prepared by conventional spray pyrolysis technique on glass at 375 °C substrate temperature. The pH of the spray solution was varied by adding ammonia/hydrochloric acid in the spray solution. The XRD pattern showed cubic phase. A lowest resistivity of 9.9 × 10{sup −4} Ω cm (with carrier concentration (n) = 5.1 × 10{sup 20} cm{sup −3}, mobility (µ)=12.4 cm{sup 2}/Vs) is observed for pH ∼12. The resistivity is tuned almost by three orders of magnitude by controlling the bath pH with optical transmittance more than 70 %. Thus, without any doping, the electricalmore » conductivity of CdO films could be easily tuned by simply varying the pH of spray solution without compromising the transparency and keeping the other deposition parameters fixed.« less
Solving general gauge theories on inner product spaces
NASA Astrophysics Data System (ADS)
Batalin, Igor; Marnelius, Robert
1995-02-01
By means of a generalized quartet mechanism we show in a model independent way that a BRST quantization on an inner product space leads to physical states of the form ph> = exp [ Q, ψ]ph> 0 where Q is the nilpotent BRST operator, ψ a hermitian fermionic gauge-fixing operator, and ph> o BRST invariant states determined by a hermitian set of BRST doublets in involution. ph> 0 does not belong to an inner product space although ph> does. Since the BRST quartets are split into two sets of hermitian BRST doublets there are two choices for ph> 0 and the corresponding ψ. When applied to general, both irreducible and reducible, gauge theories of arbitrary rank within the BFV formulation we find that ph> 0 are trivial BRST invariant states which only depend on the matter variables for one set of solutions, and for the other set ph> 0 are solutions of a Dirac quantization. This generalizes previous Lie group solutions obtained by means of a bigrading.
Hydrogen production by sodium borohydride in NaOH aqueous solution
NASA Astrophysics Data System (ADS)
Wang, Q.; Zhang, L. F.; Zhao, Z. G.
2018-01-01
The kinetics of hydrolysis reaction of NaBH4 in NaOH aqueous solution is studied. The influence of pH of the NaOH aqueous solution on the rate of hydrogen production and the hydrogen production efficiency are studied for the hydrolysis reaction of NaBH4. The results show that the activation energy of hydrolysis reaction of NaBH4 increased with the increase of the initial pH of NaOH aqueous solution.With the increasing of the initial pH of NaOH aqueous solution, the rate of hydrogen production and hydrogen production efficiency of NaBH4 hydrolysis decrease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gritti, Fabrice; Guiochon, Georges A
2009-01-01
The single-component equilibrium adsorption of the tripeptide Leucyl-Leucyl-Leucine (LLL) on a high-efficiency Jupiter Proteo column (C{sub 12}) was investigated experimentally and modeled theoretically. The experimental equilibrium isotherms of LLL for adsorption on a C{sub 12} packing material from an aqueous solution of methanol (48%) and trifluoroacetic acid (0.1%) were measured by frontal analysis (FA). The FA measurements were done with two solutions, one in which the pH was controlled, the other in which it was not. Two solutions of LLL in the mobile phase were prepared (4.3 and 5.4 g/L) and their pH measured (2.94 and 2.88), respectively. The firstmore » solution was titrated with TFA to match the pH of the mobile phase (2.03), so its pH was controlled. The pH of the other solution was left uncontrolled. In both cases the isotherms could be modeled by a bi-Langmuir equation, a choice consistent with the bimodal affinity energy distribution (AED) obtained for LLL. The isotherm parameters derived from the inverse method (IM) of isotherm determination under controlled pH conditions (by fitting calculated profiles to experimental breakthrough profiles) are in a good agreement with those derived from the FA data. Under uncontrolled pH conditions, the application of IM suggests the coexistence of two different adsorption mechanisms. According to the isotherm parameters found by these three methods (FA, AED and IM), the C{sub 12}-bonded silica can adsorb around 500 and 70 g/L of LLL under controlled and uncontrolled pH conditions, respectively. The adsorption of LLL on the C{sub 12} material strongly depends on the pH of the mobile phase and on the quantity of TFA added, which plays the role of an ion-pairing agent.« less
Nam, Wonwoo; Kim, Inwoo; Lim, Mi Hee; Choi, Hye Jin; Lee, Je Seung; Jang, Ho G
2002-05-03
The reaction of [Mn(TF(4)TMAP)](CF(3)SO(3))(5) (TF(4)TMAP=meso-tetrakis(2,3,5,6-tetrafluoro-N,N,N-trimethyl-4-aniliniumyl)porphinato dianion) with H(2)O(2) (2 equiv) at pH 10.5 and 0 degrees C yielded an oxomanganese(V) porphyrin complex 1 in aqueous solution, whereas an oxomanganese(IV) porphyrin complex 2 was generated in the reactions of tert-alkyl hydroperoxides such as tert-butyl hydroperoxide and 2-methyl-1-phenyl-2-propyl hydroperoxide. Complex 1 was capable of epoxidizing olefins and exchanging its oxygen with H(2) (18)O, whereas 2 did not epoxidize olefins. From the reactions of [Mn(TF(4)TMAP)](5+) with various oxidants in the pH range 3-11, the O-O bond cleavage of hydroperoxides was found to be sensitive to the hydroperoxide substituent and the pH of the reaction solution. Whereas the O-O bond of hydroperoxides containing an electron-donating tert-alkyl group is cleaved homolytically, an electron-withdrawing substituent such as an acyl group in m-chloroperoxybenzoic acid (m-CPBA) facilitates O-O bond heterolysis. The mechanism of the O-O bond cleavage of H(2)O(2) depends on the pH of the reaction solution: O-O bond homolysis prevails at low pH and O-O bond heterolysis becomes a predominant pathway at high pH. The effect of pH on (18)O incorporation from H(2) (18)O into oxygenated products was examined over a wide pH range, by carrying out the epoxidation of carbamazepine (CBZ) with [Mn(TF(4)TMAP)](5+) and KHSO(5) in buffered H(2) (18)O solutions. A high proportion of (18)O was incorporated into the CBZ-10,11-oxide product at all pH values but this proportion was not affected significantly by the pH of the reaction solution.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azizi, Seyed Naser, E-mail: azizi@umz.ac.ir; Dehnavi, Ahmad Roozbehani, E-mail: Roozbehanisulfur@yahoo.com; Joorabdoozha, Amir
2013-05-15
Highlights: ► Silica extraction from barley husk with high purity for the synthesis of A nanozeolite. ► Free template A nanozeolite synthesized via new source of silica at low temperature. ► Optimization of SiO{sub 2}/Al{sub 2}O{sub 3}, Na{sub 2}O/SiO{sub 2} ratios, temperature and time of the synthesis. ► Utilizing of synthesized A nanozeolite for mercury removal from aqueous solutions. ► Mercury removal at optimized pH, contact time and adsorbent dose from real solution. - Abstract: In this study, synthesized Lined Type A (LTA) nanozeolite from barley husk silica (BHS) was used for mercury removal from standard and real aqueous solutions.more » The BHS in amorphous phase with 80% purity was extracted from barley husk ash (BHA), and used effectively as a new source of silica for the synthesis of NaA nanozeolite. The NaA nanocrystal in pure phase has been synthesized at low temperature, without adding any organic additives. The effects of heating time, reaction temperature, SiO{sub 2}/Al{sub 2}O{sub 3}, and Na{sub 2}O/SiO{sub 2} mole ratios on the crystallization of NaA nanozeolite were studied. The adsorption capacity of mercury (II) was studied as a function of pH, contact time, and amount of adsorbent. The crystallization of NaA nanozeolite from BHS was characterized by X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), Brunauer–Emmett–Teller (BET), and FTIR techniques. Moreover, concentration of Hg{sup 2+} ions in the aqueous solutions was analyzed by hydride generation atomic absorption spectroscopy method (HG-AAS). The standard and real samples analysis showed that NaA nanozeolite is capable of Hg{sup 2+} ions removal from the aqueous solutions. Efficiency of mercury (II) adsorption from real solutions onto the nano-sized NaA zeolite was 98%.« less
Spent NiMH batteries-The role of selective precipitation in the recovery of valuable metals
NASA Astrophysics Data System (ADS)
Bertuol, Daniel Assumpção; Bernardes, Andréa Moura; Tenório, Jorge Alberto Soares
The production of electronic equipment, such as computers and cell phones, and, consequently, batteries, has increased dramatically. One of the types of batteries whose production and consumption has increased in recent times is the nickel metal hydride (NiMH) battery. This study evaluated a hydrometallurgical method of recovery of rare earths and a simple method to obtain a solution rich in Ni-Co from spent NiMH batteries. The active materials from both electrodes were manually removed from the accumulators and leached. Several acid and basic solutions for the recovery of rare earths were evaluated. Results showed that more than 98 wt.% of the rare earths were recovered as sulfate salts by dissolution with sulfuric acid, followed by selective precipitation at pH 1.2 using sodium hydroxide. The complete process, precipitation at pH 1.2 followed by precipitation at pH 7, removed about 100 wt.% of iron and 70 wt.% of zinc from the leaching solution. Results were similar to those found in studies that used solvent extraction. This method is easy, economic, and does not pose environmental threats of solvent extraction.
Gas-liquid hybrid discharge-induced degradation of diuron in aqueous solution.
Feng, Jingwei; Zheng, Zheng; Luan, Jingfei; Li, Kunquan; Wang, Lianhong; Feng, Jianfang
2009-05-30
Degradation of diuron in aqueous solution by gas-liquid hybrid discharge was investigated for the first time. The effect of output power intensity, pH value, Fe(2+) concentration, Cu(2+) concentration, initial conductivity and air flow rate on the degradation efficiency of diuron was examined. The results showed that the degradation efficiency of diuron increased with increasing output power intensity and increased with decreasing pH values. In the presence of Fe(2+), the degradation efficiency of diuron increased with increasing Fe(2+) concentration. The degradation efficiency of diuron was decreased during the first 4 min and increased during the last 10 min with adding of Cu(2+). Decreasing the initial conductivity and increasing the air flow rate were favorable for the degradation of diuron. Degradation of diuron by gas-liquid hybrid discharge fitted first-order kinetics. The pH value of the solution decreased during the reaction process. Total organic carbon removal rate increased in the presence of Fe(2+) or Cu(2+). The generated Cl(-1), NH(4)(+), NO(3)(-), oxalic acid, acetic acid and formic acid during the degradation process were also detected. Based on the detected Cl(-1) and other intermediates, a possible degradation pathway of diuron was proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Azizah, N., E-mail: norazizahparmin84@gmail.com; Gopinath, Subash C. B.; Nadzirah, Sh.
Titanium dioxide (TiO{sub 2}) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO{sub 2} was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to anmore » acid solution. Amine and oxide functionalized TiO{sub 2} based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO{sub 2} based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO{sub 2} based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.« less
Yellow Mealworm Protein for Food Purposes - Extraction and Functional Properties
Zhao, Xue; Vázquez-Gutiérrez, José Luis; Johansson, Daniel P.; Landberg, Rikard; Langton, Maud
2016-01-01
A protocol for extraction of yellow mealworm larvae proteins was established, conditions were evaluated and the resulting protein extract was characterised. The freeze-dried yellow mealworm larvae contained around 33% fat, 51% crude protein and 43% true protein on a dry matter basis. The true protein content of the protein extract was about 75%, with an extraction rate of 70% under optimised extraction conditions using 0.25 M NaOH, a NaOH solution:ethanol defatted worm ratio of 15:1 mL/g, 40°C for 1 h and extraction twice. The protein extract was a good source of essential amino acids. The lowest protein solubility in distilled water solution was found between pH 4 and 5, and increased with either increasing or decreasing pH. Lower solubility was observed in 0.5 M NaCl solution compared with distilled water. The rheological tests indicated that temperature, sample concentration, addition of salt and enzyme, incubation time and pH alterations influenced the elastic modulus of yellow mealworm protein extract (YMPE). These results demonstrate that the functional properties of YMPE can be modified for different food applications. PMID:26840533
Micromixer-based time-resolved NMR: applications to ubiquitin protein conformation.
Kakuta, Masaya; Jayawickrama, Dimuthu A; Wolters, Andrew M; Manz, Andreas; Sweedler, Jonathan V
2003-02-15
Time-resolved NMR spectroscopy is used to studychanges in protein conformation based on the elapsed time after a change in the solvent composition of a protein solution. The use of a micromixer and a continuous-flow method is described where the contents of two capillary flows are mixed rapidly, and then the NMR spectra of the combined flow are recorded at precise time points. The distance after mixing the two fluids and flow rates define the solvent-protein interaction time; this method allows the measurement of NMR spectra at precise mixing time points independent of spectral acquisition time. Integration of a micromixer and a microcoil NMR probe enables low-microliter volumes to be used without losing significant sensitivity in the NMR measurement. Ubiquitin, the model compound, changes its conformation from native to A-state at low pH and in 40% or higher methanol/water solvents. Proton NMR resonances of the His-68 and the Tyr-59 of ubiquitin are used to probe the conformational changes. Mixing ubiquitin and methanol solutions under low pH at microliter per minute flow rates yields both native and A-states. As the flow rate decreases, yielding longer reaction times, the population of the A-state increases. The micromixer-NMR system can probe reaction kinetics on a time scale of seconds.
Sundaramurthi, Prakash; Suryanarayanan, Raj
2011-06-02
Macromolecules and other thermolabile biologicals are often buffered and stored in frozen or dried (freeze-dried) state. Crystallization of buffer components in frozen aqueous solutions and the consequent pH shifts were studied in carboxylic (succinic, malic, citric, tartaric acid) and amino acid (glycine, histidine) buffers. Aqueous buffer solutions were cooled from room temperature (RT) to -25 °C and the pH of the solution was measured as a function of temperature. The thermal behavior of frozen solutions was investigated by differential scanning calorimetry (DSC), and the crystallized phases were identified by X-ray diffractometry (XRD). Based on the solubility of the neutral species of each buffer system over a range of temperatures, it was possible to estimate its degree of supersaturation at the subambient temperature of interest. This enabled us to predict its crystallization propensity in frozen systems. The experimental and the predicted rank orderings were in excellent agreement. The malate buffer system was robust with no evidence of buffer component crystallization and hence negligible pH shift. In the citrate and tartrate systems, at initial pH < pK(a)(2), only the most acidic buffer component (neutral form) crystallized on cooling, causing an increase in the freeze-concentrate pH. In glycine buffer solutions, when the initial pH was ∼3 units < isoelectric pH (pI = 5.9), β-glycine crystallization caused a small decrease in pH, while a similar effect but in the opposite direction was observed when the initial pH was ∼3 units > pI. In the histidine buffer system, depending on the initial pH, either histidine or histidine HCl crystallized.
Solution and surface effects on plasma fibronectin structure
1983-01-01
As assessed by electron microscopy, the reported shape of the plasma fibronectin molecule ranges from that of a compact particle to an elongated, rod-like structure. In this study, we evaluated the effects of solution and surface conditions on fibronectin shape. Freeze-dried, unstained human plasma fibronectin molecules deposited at pH 7.0-7.4 onto carbon films and examined by scanning transmission electron microscopy appeared relatively compact and pleiomorphic, with approximate average dimensions of 24 nm X 16 nm. Negatively stained molecules also had a similar shape but revealed greater detail in that we observed irregular, yarn-like structures. Glutaraldehyde-induced intramolecular cross-linking did not alter the appearance of plasma fibronectin. Molecules deposited at pH 2.8, pH 9.3, or after succinylation were less compact than those deposited at neutral pH. In contrast, fibronectin molecules sprayed onto mica surfaces at pH 7, rotary shadowed, and examined by transmission electron microscopy were elongated and nodular with a contour length of 120-130 nm. Sedimentation velocity experiments and electron microscopic observations indicate that fibronectin unfolds when it is succinylated, when the ionic strength is raised at pH 7, or when the pH is adjusted to 9.3 or 2.8. Greater unfolding is observed at pH 2.8 at low ionic strength (less than 0.01) compared with material at that pH in 0.15 M NaCl solution. We conclude that (a) the shape assumed by the fibronectin molecule can be strongly affected by solution conditions and by deposition onto certain surfaces; and that (b) the images of fibronectin seen by scanning transmission electron microscopy at neutral pH on carbon film are representative of molecules in physiologic solution. PMID:6417145
Individual and Co Transport Study of Titanium Dioxide NPs and Zinc Oxide NPs in Porous Media
Kumari, Jyoti; Mathur, Ankita; Rajeshwari, A.; Venkatesan, Arthi; S, Satyavati; Pulimi, Mrudula; Chandrasekaran, Natarajan; Nagarajan, R.; Mukherjee, Amitava
2015-01-01
The impact of pH and ionic strength on the mobility (individual and co-transport) and deposition kinetics of TiO2 and ZnO NPs in porous media was systematically investigated in this study. Packed column experiments were performed over a series of environmentally relevant ionic strengths with both NaCl (0.1−10 mM) and CaCl2 (0.01–0.1mM) solutions and at pH 5, 7, and 9. The transport of TiO2 NPs at pH 5 was not significantly affected by ZnO NPs in solution. At pH 7, a decrease in TiO2 NP transport was noted with co-existence of ZnO NPs, while at pH 9 an increase in the transport was observed. At pH 5 and 7, the transport of ZnO NPs was decreased when TiO2 NPs was present in the solution, and at pH 9, an increase was noted. The breakthrough curves (BTC) were noted to be sensitive to the solution chemistries; the decrease in the breakthrough plateau with increasing ionic strength was observed under all examined pH (5, 7, and 9). The retention profiles were the inverse of the plateaus of BTCs, as expected from mass balance considerations. Overall, the results from this study suggest that solution chemistries (ionic strength and pH) are likely the key factors that govern the individual and co-transport behavior of TiO2 and ZnO NPs in sand. PMID:26252479
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lwin, Nilar, E-mail: nilarlwin111@gmail.com; School of Materials and Mineral Resources Engineering, Universiti Sains Malaysia, Engineering Campus, 14300 Nibong Tebal, Penang; Othman, Radzali, E-mail: radzali@utem.edu.my
The synthesis of nano-crystalline Mg–Mn ferrites by a solution combustion method using citric acid and ammonia was investigated by varying the pH of the precursor solution, which played an important role in controlling the morphology of the synthesized powders. The phase formation, microstructure and electromagnetic properties were studied using X-ray diffraction, scanning electron microscopy, impedance analyzer and vibrating sample magnetometer. Single phase pure spinel Mg–Mn ferrite powders were obtained for all the samples at different pH (< 1, 3, 5, 7, 9). The results showed that an increase of pH improves the crystallinity of the Mg–Mn ferrite nanoparticles. The averagemore » grain size of sintered samples was found to decrease from 2 μm to 0.5 μm with increasing pH values from pH < 1 to pH 9, respectively. The dielectric constant of the samples with different pH is in the range of 7–12 from frequencies of 1 MHz to 1 GHz. The highest saturation magnetization (30.04 emu/g) was obtained for the sample with pH < 1. - Highlights: • Mg–Mn ferrites were synthesized by a solution combustion method with different pH. • Auto-combustion process resulted in the formation of single phase spinel ferrite. • An increase of pH improves the crystallinity of the Mg–Mn ferrite nanoparticles. • pH variation has influence on phase formation and morphology of the ferrite.« less
Grim, Eugene; Sollner, Karl
1957-01-01
The osmotic effect arising across a porous membrane separating the solution of an electrolyte from water (or a more dilute solution) is ordinarily due to both normal osmosis, as it occurs also with non-electrolytes, and to "anomalous" osmosis. It is shown that the normal osmotic component cannot be measured quantitatively by the conventional comparison with a non-electrolytic reference solute. Anomalous osmosis does not occur with electroneutral membranes. Accordingly, with membranes which can be charged and discharged reversibly (without changes in geometrical structure), such as many proteinized membranes, the osmotic effects caused by an electrolyte can be measured both when only normal osmosis arises (with the membrane in the electroneutral state) and when normal as well as anomalous osmosis occurs (with the membrane in a charged state). The difference between these two effects is the true anomalous osmosis. Data are presented on the osmotic effects across an oxyhemoglobin membrane in the uncharged state at pH 6.75 and in two charged states, positive at pH 4.0 and negative at pH 10.0, with solutions of a variety of electrolytes using a concentration ratio of 2:1 over a wide range of concentrations. The rates of the movement of liquid across the membrane against an inconsequentially small hydrostatic head are recorded instead of, as conventional, the physiologically less significant pressure rises after a standard time. PMID:13439166
Hartl, Josef; Peschel, Astrid; Johannsmann, Diethelm; Garidel, Patrick
2017-12-13
Making use of a quartz crystal microbalance (QCM), concentrated solutions of therapeutic antibodies were studied with respect to their behavior under shear excitation with frequencies in the MHz range. At high protein concentration and neutral pH, viscoelastic behavior was found in the sense that the storage modulus, G', was nonzero. Fits of the frequency dependence of G'(ω) and G''(ω) (G'' being the loss modulus) using the Maxwell-model produced good agreement with the experimental data. The fit parameters were the relaxation time, τ, and the shear modulus at the inverse relaxation time, G* (at the "cross-over frequency" ω C = 1/τ). The influence of two different pharmaceutical excipients (histidine and citrate) was studied at variable concentrations of the antibody and variable pH. In cases, where viscoelasticity was observed, G* was in the range of a few kPa, consistent with entropy-driven interactions. τ was small at low pH, where the antibody carries a positive charge. τ increased with increasing pH. The relaxation time τ was found to be correlated with other parameters quantifying protein-protein interactions, namely the steady shear viscosity (η), the second osmotic virial coefficient as determined with both self-interaction chromatography (B 22,SIC ) and static light scattering (B 22,SLS ), and the diffusion interaction parameter as determined with dynamic light scattering (k D ). While B 22 and k D describe protein-protein interactions in diluted samples, the QCM can be applied to concentrated solutions, thereby being sensitive to higher-order protein-protein interactions.
Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook
Kurzweil, Peter
2009-01-01
Novel applications of online pH determinations at temperatures from -35 °C to 130 °C in technical and biological media, which are all but ideal aqueous solutions, require new approaches to pH monitoring. The glass electrode, introduced nearly hundred years ago, and chemical sensors based on field effect transistors (ISFET) show specific drawbacks with respect to handling and long-time stability. Proton sensitive metal oxides seem to be a promising and alternative to the state-of-the-art measuring methods, and might overcome some problems of classical hydrogen electrodes and reference electrodes. PMID:22408563
PROCESSES OF RECLAIMING URANIUM FROM SOLUTIONS
Zumwalt, L.R.
1959-02-10
A process is described for reclaiming residual enriched uranium from calutron wash solutions containing Fe, Cr, Cu, Ni, and Mn as impurities. The solution is adjusted to a pH of between 2 and 4 and is contacted with a metallic reducing agent, such as iron or zinc, in order to reduce the copper to metal and thereby remove it from the solution. At the same time the uranium present is reduced to the uranous state The solution is then contacted with a precipitate of zinc hydroxide or barium carbonate in order to precipitate and carry uranium, iron, and chromium away from the nickel and manganese ions in the solution. The uranium is then recovered fronm this precipitate.
The removal of chloramphenicol from water through adsorption on activated carbon
NASA Astrophysics Data System (ADS)
Lach, Joanna; Ociepa-Kubicka, Agnieszka
2017-10-01
The presented research investigated the removal of chloramphenicol from water solutions on selected activated carbon available in three grades with different porous structure and surface chemical composition. Two models of adsorption kinetics were examined, i.e. the pseudo-first order and the pseudo-second order models. For all examined cases, the results of tests with higher value of coefficient R2 were described by the equation for pseudo-second order kinetics. The adsorption kinetics was also investigated on the activated carbons modified with ozone. The measurements were taken from the solutions with pH values of 2 and 7. Chloramphenicol was the most efficiently adsorbed on the activated carbon F-300 from the solutions with pH=7, and on the activated carbon ROW 08 Supra from the solutions with pH=2. The adsorption of this antibiotic was in the majority of cases higher from the solutions with pH=2 than pH=7. The modification of the activated carbons with ozone enhanced their adsorption capacities for chloramphenicol. The adsorption is influenced by the modification method of activated carbon (i.e. the duration of ozonation of the activated carbon solution and the solution temperature). The results were described with the Freundlich and Langmuir adsorption isotherm equations. Both models well described the obtained results (high R2 values).
NASA Astrophysics Data System (ADS)
Fu, Jingni; Zhang, Luning
2018-03-01
The protonation/deprotonation equilibrium of a fluorescent pH probe (carboxy-seminaphthorhodafluor-1, SNARF-1) within the nanoscale water layer confined in common black films (CBFs) has been studied. We find that SNARF-1 molecules feel a more acidic environment in CBFs than when they are in the bulk micellar solution, using the base/acid peak area ratio of the dye to indicate its microenvironment pH. Three surfactants are used to study the dependence of the pH drop versus charge: cationic (cetyltrimethylammonium bromide, CTAB), anionic (sodium dodecylsulphate, SDS) and nonionic (Triton X-100) species. The decrease of CBFs pH versus the pH of the micellar solution is the following: ΔpH ≈ 1.5 for CTAB (pH: 7.0-9.0), ΔpH ≈ 0.8 for SDS, and ΔpH ≈ 0.4 for Triton X-100. With the addition of electrolyte in CBFs, we observe large decrease the amplitude of the pH anomaly, thus suggesting an electrostatic origin of the pH change at nanoscale environment.
A process for the preparation of cysteine from cystine
Chang, Shih-Ger; Liu, David K.; Griffiths, Elizabeth A.; Littlejohn, David
1989-01-01
The present invention in one aspect relates to a process for the simultaneous removal of NO.sub.x and SO.sub.2 from a fluid stream comprising mixtures thereof and in another aspect relates to the separation, use and/or regeneration of various chemicals contaminated or spent in the process and which includes the steps of: (A) contacting the fluid stream at a temperature of between about 105.degree. and 180.degree. C. with a liquid aqueous slurry or solution comprising an effective amount of an iron chelate of an amino acid moiety having at least one --SH group; (B) separating the fluid stream from the particulates formed in step (A) comprising the chelate of the amino acid moiety and fly ash; (C) washing and separating the particulates of step (B) with an aqeous solution having a pH value of between about 5 to 8; (D) subsequently washing and separating the particulates of step (C) with a strongly acidic aqueous solution having a pH value of between about 1 to 3; (E) washing and separating the particulates of step (D) with an basic aqueous solution having a pH value of between about 9 to 12; (F) optionally adding additional amino acid moiety, iron (II) and alkali to the aqueous liquid from step (D) to produce an aqueous solution or slurry similar to that in step (A) having a pH value of between about 4 to 12; and (G) recycling the aqueous slurry of step (F) to the contacting zone of step (A). Steps (D) and (E) can be carried out in the reverse sequence, however the preferred order is (D) and then (E). In a preferred embodiment the present invention provides an improved process for the preparation (regeneration) of cysteine from cystine, which includes reacting an aqueous solution of cystine at a pH of between about 9 to 13 with a reducing agent selected from hydrogen sulfide or alkali metal sulfides, sulfur dioxide, an alkali metal sulfite or mixtures thereof for a time and at a temperature effective to cleave and reduce the cystine to cysteine with subsequent recovery of the cysteine. In another preferred embodiment the present invention provides a process for the removal of NO.sub.x, SO.sub.2 and particulates from a fluid stream which includes the steps of (A) injecting into a reaction zone an aqueous solution itself comprising (i) an amino acid moiety selected from those described above; (ii) iron (II) ion; and (iii) an alkali, wherein the aqueous solution has a pH of between about 4 and 11; followed by solids separation and washing as is described in steps (B), (C), (D) and (E) above. The overall process is useful to reduce acid rain components from combustion gas sources.
Survival of Escherichia coli after isoelectric solubilization and precipitation of fish protein.
Lansdowne, L R; Beamer, S; Jaczynski, J; Matak, K E
2009-07-01
Protein recovery for fish processing by-products utilizes extreme pH shifts for isoelectric solubilization and precipitation. The purpose of this study was to determine if Escherichia coli would survive exposure to the extreme pH shifts during the protein recovery process. Fresh rainbow trout were beheaded, gutted, and minced and then inoculated with approximately 10(9) CFU of E. coli ATCC 25922 per g, homogenized, and brought to the target pH of 2.0, 3.0, 11.5, or 12.5 by the addition of concentrated hydrochloric acid or sodium hydroxide to solubilize muscle proteins. The homogenate was blended and centrifuged to separate the lipid and insoluble components (bones, skin, insoluble protein, etc.) from the protein solution. The protein solution was subjected to a second pH shift (pH 5.5) resulting in protein precipitation that was recovered with centrifugation. Microbial analysis was conducted on each fraction (i.e., lipid, insoluble components, protein, and water) with selective and nonselective media. The sums of the surviving E. coli in these fractions were compared with the initial inoculum. The greatest total microbial reduction occurred when the pH was shifted to 12.5 (P < 0.05), i.e., a 4.4-log reduction of cells on nonselective media and a 6.0-log reduction of cells on selective media. The use of selective and nonselective media showed that there was significant (P < 0.05) injury sustained by cells exposed to alkaline treatment (pH 11.5 and 12.5) in all fractions except the insoluble fraction at pH 11.5. Increasing the exposure time or the pH may result in greater bacterial reductions in the recovered protein.
Wang, Congjun; Ohodnicki, Paul R; Su, Xin; Keller, Murphy; Brown, Thomas D; Baltrus, John P
2015-02-14
Silica and silica incorporated nanocomposite materials have been extensively studied for a wide range of applications. Here we demonstrate an intriguing optical effect of silica that, depending on the solution pH, amplifies or attenuates the optical absorption of a variety of embedded optically active materials with very distinct properties, such as plasmonic Au nanoparticles, non-plasmonic Pt nanoparticles, and the organic dye rhodamine B (not a pH indicator), coated on an optical fiber. Interestingly, the observed optical response to varying pH appears to follow the surface charge density of the silica matrix for all the three different optically active materials. To the best of our knowledge, this optical effect has not been previously reported and it appears universal in that it is likely that any optically active material can be incorporated into the silica matrix to respond to solution pH or surface charge density variations. A direct application of this effect is for optical pH sensing which has very attractive features that can enable minimally invasive, remote, real time and continuous distributed pH monitoring. Particularly, as demonstrated here, using highly stable metal nanoparticles embedded in an inorganic silica matrix can significantly improve the capability of pH sensing in extremely harsh environments which is of increasing importance for applications in unconventional oil and gas resource recovery, carbon sequestration, water quality monitoring, etc. Our approach opens a pathway towards possible future development of robust optical pH sensors for the most demanding environmental conditions. The newly discovered optical effect of silica also offers the potential for control of the optical properties of optically active materials for a range of other potential applications such as electrochromic devices.
Assessment of iron chelates efficiency for photo-Fenton at neutral pH.
De Luca, Antonella; Dantas, Renato F; Esplugas, Santiago
2014-09-15
In this study, homogeneous photo-Fenton like at neutral pH was applied to remove sulfamethoxazole from water. The process was performed using different chelating agents in order to solubilize iron in a neutral water solution. The chelating agents tested were: ethylenediaminetetraacetic acid (EDTA); nitrilotriacetic acid (NTA); oxalic acid (OA) and tartaric acid (TA). The iron leaching was monitored over reaction time to evaluate the chelates stability and their resistance to HO· and UV-A radiation. Chelates of EDTA and NTA presented more stability than OA and TA, which also confirmed their higher efficiency. Total Organic Carbon (TOC) analyses were also performed to evaluate the contribution in terms of solution contamination related to the use of chelating agents. The better properties of biodegradability in respect of EDTA combined with better efficiency in terms of microcontaminant removal and the smallest TOC contribution indicate that NTA could represent a useful option to perform photo-Fenton processes at neutral pH. Copyright © 2014 Elsevier Ltd. All rights reserved.
Stimuli Responsive Morphological Changes of Pnipa Polymer Brushes Synthesized on Silicon Substrate
NASA Astrophysics Data System (ADS)
Huda, Muhammad Nurul; Kabir, A. N. M. Hamidul
2013-08-01
High-density polymer brushes were grown from the silicon surface by atom transfer radical polymerization of Poly(N-isopropylacrylamide) (PNIPA) at different polymerization conditions. PNIPA brushes were prepared using Copper (I) Chloride/tris(2-(dimetylamino)ethyl)amine (Me6TREN) as a catalytic system in DMSO at 20°C. Free polymer formed during the brush formation was characterized by gel permeation chromatography. The grafting densities up to 0.52 chains/nm2 were obtained. The layer thickness of polymer brush increases with the increase of conversion of the monomer conversion as well as polymerization time. Atomic force microscopy and air bubble contact angle under pH solution were employed to study the surface morphology, reversible conformational changes of and stimulus-response behavior. PNIPA brushes exhibited a different nanomorphology after treatment with different pH solution. It also revealed a unique reversible wetting behavior with pH. The reversible properties of the PNIPA brushes can be used to regulate the adsorption of the sulfonated PS nanoparticles.
Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.
Proença, Martin; Braun, Fabian; Solà, Josep; Thiran, Jean-Philippe; Lemay, Mathieu
2017-06-01
Current monitoring modalities for patients with pulmonary hypertension (PH) are limited to invasive solutions. A novel approach for the noninvasive and unsupervised monitoring of pulmonary artery pressure (PAP) in patients with PH was proposed and investigated. The approach was based on the use of electrical impedance tomography (EIT), a noninvasive and safe monitoring technique, and was tested through simulations on a realistic 4D bio-impedance model of the human thorax. Changes in PAP were induced in the model by simulating multiple types of hypertensive conditions. A timing parameter physiologically linked to the PAP via the so-called pulse wave velocity principle was automatically estimated from the EIT data. It was found that changes in PAP could indeed be reliably monitored by EIT, irrespective of the pathophysiological condition that caused them. If confirmed clinically, these findings could open the way for a new generation of noninvasive PAP monitoring solutions for the follow-up of patients with PH.
Hubicka, Urszula; Zmudzki, Paweł; Zajdel, Paweł; Krzek, Jan
2013-01-01
A simple, sensitive, and reproducible ultra-performance LC method for the determination of moxifloxacin (MOXI) oxidation stability under permanganate treatment in acidic conditions (pH 3.0-6.0) was developed. Besides the MOXI peak [retention time (RT) = 2.58], four additional products (RT = 0.86, 0.91, 1.42, and 1.89) were observed in all conditions tested. The oxidation process followed second-order reaction kinetics and depended upon solution acidity. The highest reaction rate constant was observed at pH 3.0, and this value decreased as the pH was increased to 6.0. The oxidation products were characterized, and their fragmentation pathways, derived from MS/MS data, were proposed. Two of these products were identified as hydroxyl derivatives of MOXI and two others as their oxidation product analogs with molecular ions of 418.4 and 416.4 m/z, respectively.
Chemical induced demineralization study in cortical bone
NASA Astrophysics Data System (ADS)
Sales, E.; da Silva, C. E. R.; Letichevsky, S.; dos Santos, R.; Leitao, R.; dos Santos, C. T.; de Oliveira, L. F.; de Avillez, R.; Monteiro, M.; Costa-Felix, R.; Paciornik, S.; dos Anjos, M.
2018-05-01
In this work we present a study of demineralization in bovine cortical bone. We selected 9 fresh cortical bone samples from 2 diaphyseal femurs for analysis. Samples were demineralized for 24 h, 48 h, 72 h and 96 h using two concentrations of EDTA with different pH: EDTA 0.1 M (pH 10, alkaline) and EDTA 0.5 M (pH 7.4, neutral). We have employed μ-X-ray fluorescence (μ-XRF) and X-ray diffraction (XRD) to assess the degree of demineralization. EDTA solutions were analyzed for Calcium (Ca) and Phosphorous (P) extractions by Atomic Absorption Spectrophotometry (AAS) and Ion Chromatography (IC), respectively. Results from AAS and IC showed that EDTA 0.5 M (pH 7.4) removed two times more Ca and 3 times more P than EDTA 0.1 M (pH 10) in the first 24 hours. μ-XRF results presented that EDTA has a high capacity to bind Calcium and Phosphorus. On the other hand, despite the differences in concentration and pH, EDTA did not bind Zn and Sr. Results from XRD showed that EDTA with high concentration had a greater impact to the samples' crystallinity causing a severe damage.
NASA Astrophysics Data System (ADS)
Hermkens, Niels K. J.; Feiters, Martin C.; Rutjes, Floris P. J. T.; Wijmenga, Sybren S.; Tessari, Marco
2017-03-01
SABRE (Signal Amplification By Reversible Exchange) is a nuclear spin hyperpolarization technique based on the reversible concurrent binding of small molecules and para-hydrogen (p-H2) to an iridium metal complex in solution. At low magnetic field, spontaneous conversion of p-H2 spin order to enhanced longitudinal magnetization of the nuclear spins of the other ligands occurs. Subsequent complex dissociation results in hyperpolarized substrate molecules in solution. The lifetime of this complex plays a crucial role in attained SABRE NMR signal enhancements. Depending on the ligands, vastly different dissociation rates have been previously measured using EXSY or selective inversion experiments. However, both these approaches are generally time-consuming due to the long recycle delays (up to 2 min) necessary to reach thermal equilibrium for the nuclear spins of interest. In the cases of dilute solutions, signal averaging aggravates the problem, further extending the experimental time. Here, a new approach is proposed based on coherent hyperpolarization transfer to substrate protons in asymmetric complexes at high magnetic field. We have previously shown that such asymmetric complexes are important for application of SABRE to dilute substrates. Our results demonstrate that a series of high sensitivity EXSY spectra can be collected in a short experimental time thanks to the NMR signal enhancement and much shorter recycle delay.
Biosorption of copper by marine algae Gelidium and algal composite material in a packed bed column.
Vilar, Vítor J P; Botelho, Cidália M S; Loureiro, José M; Boaventura, Rui A R
2008-09-01
Marine algae Gelidium and algal composite material were investigated for the continuous removal of Cu(II) from aqueous solution in a packed bed column. The biosorption behaviour was studied during one sorption-desorption cycle of Cu(II) in the flow through column fed with 50 and 25 mg l(-1) of Cu(II) in aqueous solution, at pH 5.3, leading to a maximum uptake capacity of approximately 13 and 3 mg g(-1), respectively, for algae Gelidium and composite material. The breakthrough time decreases as the inlet copper concentration increases, for the same flow rate. The pH of the effluent decreases over the breakthrough time of copper ions, which indicates that ion exchange is one of the mechanisms involved in the biosorption process. Temperature has little influence on the metal uptake capacity and the increase of the ionic strength reduces the sorption capacity, decreasing the breakthrough time. Desorption using 0.1M HNO(3) solution was 100% effective. After two consecutive sorption-desorption cycles no changes in the uptake capacity of the composite material were observed. A mass transfer model including film and intraparticle resistances, and the equilibrium relationship, for adsorption and desorption, was successfully applied for the simulation of the biosorption column performance.
SEPARATION OF BARIUM VALUES FROM URANYL NITRATE SOLUTIONS
Tompkins, E.R.
1959-02-24
The separation of radioactive barium values from a uranyl nitrate solution of neutron-irradiated uranium is described. The 10 to 20% uranyl nitrate solution is passed through a flrst column of a cation exchange resin under conditions favoring the adsorption of barium and certain other cations. The loaded resin is first washed with dilute sulfuric acid to remove a portion of the other cations, and then wash with a citric acid solution at pH of 5 to 7 to recover the barium along with a lesser amount of the other cations. The PH of the resulting eluate is adjusted to about 2.3 to 3.5 and diluted prior to passing through a smaller second column of exchange resin. The loaded resin is first washed with a citric acid solution at a pH of 3 to elute undesired cations and then with citric acid solution at a pH of 6 to eluts the barium, which is substantially free of undesired cations.
Abid Charef, S; Affoune, A M; Caballero, A; Cruz-Yusta, M; Morales, J
2017-10-01
A parallel study of acidic and alkaline leaching for the recovery of Mn and Zn from spent alkaline batteries is outlined. Using H 2 SO 4 as solvent and selecting appropriate conditions of temperature and concentration, all residues were dissolved except carbon. The separation and recovery of the two components were performed by electrodeposition with satisfactory results at pH values above 4 (current efficiency above 70% for Zn and Mn) but rather lower efficiencies as the pH decreased. Most of the Zn was selectively dissolved by alkaline leaching using a 6.5M NaOH solution, and its recovery was examined by means of both electrochemical and chemical processes. The expected formation of pure Zn by electrowinning failed due to the formation of ZnO, the content of which was highly dependent on the electrodeposition time. For short periods, Zn was the main component. For longer periods the electrodeposit consisted of agglomerated microparticles of ZnO with a minor fraction of Zn metal (barely 3% as measured by X-ray diffraction). A chemical reaction of the element with oxygen released at the anode surface might be responsible for its conversion to ZnO. A simple chemical route is described for the first time for the direct conversion of Zn(OH) 4 2- solution to nanostructured ZnO by lowering the pH to values around 12 using 2M HCl solution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Acidosis slows electrical conduction through the atrio-ventricular node
Nisbet, Ashley M.; Burton, Francis L.; Walker, Nicola L.; Craig, Margaret A.; Cheng, Hongwei; Hancox, Jules C.; Orchard, Clive H.; Smith, Godfrey L.
2014-01-01
Acidosis affects the mechanical and electrical activity of mammalian hearts but comparatively little is known about its effects on the function of the atrio-ventricular node (AVN). In this study, the electrical activity of the epicardial surface of the left ventricle of isolated Langendorff-perfused rabbit hearts was examined using optical methods. Perfusion with hypercapnic Tyrode's solution (20% CO2, pH 6.7) increased the time of earliest activation (Tact) from 100.5 ± 7.9 to 166.1 ± 7.2 ms (n = 8) at a pacing cycle length (PCL) of 300 ms (37°C). Tact increased at shorter PCL, and the hypercapnic solution prolonged Tact further: at 150 ms PCL, Tact was prolonged from 131.0 ± 5.2 to 174.9 ± 16.3 ms. 2:1 AVN block was common at shorter cycle lengths. Atrial and ventricular conduction times were not significantly affected by the hypercapnic solution suggesting that the increased delay originated in the AVN. Isolated right atrial preparations were superfused with Tyrode's solutions at pH 7.4 (control), 6.8 and 6.3. Low pH prolonged the atrial-Hisian (AH) interval, the AVN effective and functional refractory periods and Wenckebach cycle length significantly. Complete AVN block occurred in 6 out of 9 preparations. Optical imaging of conduction at the AV junction revealed increased conduction delay in the region of the AVN, with less marked effects in atrial and ventricular tissue. Thus acidosis can dramatically prolong the AVN delay, and in combination with short cycle lengths, this can cause partial or complete AVN block and is therefore implicated in the development of brady-arrhythmias in conditions of local or systemic acidosis. PMID:25009505
Acidosis slows electrical conduction through the atrio-ventricular node.
Nisbet, Ashley M; Burton, Francis L; Walker, Nicola L; Craig, Margaret A; Cheng, Hongwei; Hancox, Jules C; Orchard, Clive H; Smith, Godfrey L
2014-01-01
Acidosis affects the mechanical and electrical activity of mammalian hearts but comparatively little is known about its effects on the function of the atrio-ventricular node (AVN). In this study, the electrical activity of the epicardial surface of the left ventricle of isolated Langendorff-perfused rabbit hearts was examined using optical methods. Perfusion with hypercapnic Tyrode's solution (20% CO2, pH 6.7) increased the time of earliest activation (Tact) from 100.5 ± 7.9 to 166.1 ± 7.2 ms (n = 8) at a pacing cycle length (PCL) of 300 ms (37°C). Tact increased at shorter PCL, and the hypercapnic solution prolonged Tact further: at 150 ms PCL, Tact was prolonged from 131.0 ± 5.2 to 174.9 ± 16.3 ms. 2:1 AVN block was common at shorter cycle lengths. Atrial and ventricular conduction times were not significantly affected by the hypercapnic solution suggesting that the increased delay originated in the AVN. Isolated right atrial preparations were superfused with Tyrode's solutions at pH 7.4 (control), 6.8 and 6.3. Low pH prolonged the atrial-Hisian (AH) interval, the AVN effective and functional refractory periods and Wenckebach cycle length significantly. Complete AVN block occurred in 6 out of 9 preparations. Optical imaging of conduction at the AV junction revealed increased conduction delay in the region of the AVN, with less marked effects in atrial and ventricular tissue. Thus acidosis can dramatically prolong the AVN delay, and in combination with short cycle lengths, this can cause partial or complete AVN block and is therefore implicated in the development of brady-arrhythmias in conditions of local or systemic acidosis.
Bliss, Donna Z; Bland, Peggy; Wiltzen, Kjerstie; Gannon, Alexandra; Wilhems, Anna; Mathiason, Michelle A; Turnbaugh, Robert
The study's purpose was to assess the pH of the skin of older (aged ≥75 years) incontinent nursing home residents after exposure to an incontinence brief containing spiral-shaped fiber wet with an alkaline solution mimicking urine or fecal pH and compared to skin pH after exposure to an industry standard brief wet with the same solution and various controls. The design was experimental, as conditions were applied to skin and skin pH was measured in random order, and subjects served as their own controls. The setting was a Midwestern nonprofit nursing home. The sample was 26 nursing home residents; their mean age was 87 years (SD = 6 years); 77% were female. Most (69%) had urinary incontinence alone, and 31% had dual urinary and fecal incontinence. Skin pH was measured in duplicate on 6 areas of the inner thighs and 6 areas of the volar surface of the forearms. Each area was exposed to 1 of 6 conditions applied in random order: an incontinence brief containing spiral-shaped fiber wet with an alkaline solution and one that was dry; a standard incontinence brief (without spiral-shaped fiber) wet with the same alkaline solution and one that was dry; the alkaline solution alone; and normal skin. On both the thighs and the forearms, skin pH was significantly lower (more acidic) after exposure to the incontinence brief containing spiral-shaped fiber wet with an alkaline solution compared to the wet standard brief and all other control conditions (P < .001). On thighs, the mean skin pH was 5.7 (SD = 0.5) after exposure to the wet brief with spiral-shaped fiber versus 6.4 (SD = 0.5) after exposure to the wet standard brief. On forearms, the mean skin pH was 5.3 (SD = 0.4) after exposure to the wet brief with spiral-shaped fiber versus 6.0 (SD = 0.4) after exposure to the wet standard brief. Incontinence briefs containing a spiral-shaped fiber significantly acidify the pH of the skin exposed to an alkaline solution, while industry standard briefs do not. Since alkaline skin pH is a risk factor for incontinence-associated dermatitis (IAD), results suggest that briefs with spiral-shaped fiber may help prevent IAD. Findings encourage further research.
PHOTOMETRIC ORBITS OF EXTRASOLAR PLANETS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Robert A.
We define and analyze the photometric orbit (PhO) of an extrasolar planet observed in reflected light. In our definition, the PhO is a Keplerian entity with six parameters: semimajor axis, eccentricity, mean anomaly at some particular time, argument of periastron, inclination angle, and effective radius, which is the square root of the geometric albedo times the planetary radius. Preliminarily, we assume a Lambertian phase function. We study in detail the case of short-period giant planets (SPGPs) and observational parameters relevant to the Kepler mission: 20 ppm photometry with normal errors, 6.5 hr cadence, and three-year duration. We define a relevantmore » 'planetary population of interest' in terms of probability distributions of the PhO parameters. We perform Monte Carlo experiments to estimate the ability to detect planets and to recover PhO parameters from light curves. We calibrate the completeness of a periodogram search technique, and find structure caused by degeneracy. We recover full orbital solutions from synthetic Kepler data sets and estimate the median errors in recovered PhO parameters. We treat in depth a case of a Jupiter body-double. For the stated assumptions, we find that Kepler should obtain orbital solutions for many of the 100-760 SPGP that Jenkins and Doyle estimate Kepler will discover. Because most or all of these discoveries will be followed up by ground-based radial velocity observations, the estimates of inclination angle from the PhO may enable the calculation of true companion masses: Kepler photometry may break the 'msin i' degeneracy. PhO observations may be difficult. There is uncertainty about how low the albedos of SPGPs actually are, about their phase functions, and about a possible noise floor due to systematic errors from instrumental and stellar sources. Nevertheless, simple detection of SPGPs in reflected light should be robust in the regime of Kepler photometry, and estimates of all six orbital parameters may be feasible in at least a subset of cases.« less
Watanabe, Yoshiteru; Mukai, Baku; Kawamura, Ken-ichi; Ishikawa, Tatsuya; Namiki, Michihiro; Utoguchi, Naoki; Fujii, Makiko
2002-02-01
In an attempt to achieve chronopharmacotherapy for asthma, press-coated tablets (250 mg), which contained aminophylline in the core tablet in the form of low-substituted hydroxypropylcellulose (L-HPC) and coated with crystalline cellulose (PH-102) and polyethylene glycol (PEG) at various molecular weights and mixing ratios in the amounts of PH-102 and PEG as the outer shell (press-coating material), were prepared (chronopharmaceutics). Their applicability as timed-release (delayed-release) tablets with a lag time of disintegration and a subsequent rapid drug release phase was investigated. Various types of press-coated tablets were prepared using a tableting machine, and their aminophylline dissolution profiles were evaluated by the JP paddle method. Tablets with the timed-release characteristics could be prepared, and the lag time of disintegration was prolonged as the molecular weight and the amount of PEG, for example PEG 500,000, in the outer shell were increased. The lag time of disintegration could be controlled by the above-mentioned method, however, the pH of the medium had no effect on disintegration of the tablet and dissolution behavior of theophylline. The press-coated tablet (core tablet:aminophylline 50 mg, L-HPC and PEG 6000; outer shell:PH-102:PEG = 8:2 200 mg) with the timed-release characteristics was administered orally to rabbits for an in vivo test. Theophylline was first detected in plasma more than 2 h after administration; thus, this tablet showed a timed-release characteristics in the gastrointestinal tract. The time (tmax) required to reach the maximum plasma theophylline concentration (Cmax) observed after administration of the press-coated tablet was significantly (p < 0.05) delayed compared with that observed after administration of aminophylline solution in the control experiment. However, there was no difference in Cmax and area under the plasma theophylline concentration-time curve (AUC0-->24) between the press-coated tablet and aminophylline solution. These results suggest that the press-coated aminophylline tablet (with the timed-release characteristic) offers a promising forms of theophylline chronotherapy for asthma.
NASA Astrophysics Data System (ADS)
Szewczyk-Nykiel, Aneta; Kazior, Jan
2017-07-01
The general corrosion behavior of sintered 17-4 PH stainless steel processed under different processing conditions in dilute sulfuric acid solution at 25 °C was studied by open-circuit potential measurement and potentiodynamic polarization technique. The corrosion resistance was evaluated based on electrochemical parameters, such as polarization resistance, corrosion potential, corrosion current density as well as corrosion rate. The results showed that the precipitation-hardening treatment could significantly improve the corrosion resistance of the sintered 17-4 PH stainless steel in studied environment. As far as the influence of aging temperature on corrosion behavior of the sintered 17-4 PH stainless steel is concerned, polarization resistance and corrosion rate are reduced with increasing aging temperature from 480 up to 500 °C regardless of the temperature of solution treatment. It can be concluded that the highest corrosion resistance in 0.5 M H2SO4 solution exhibits 17-4 PH after solution treatment at 1040 °C followed by aging at 480 °C.
Nettleton, E J; Tito, P; Sunde, M; Bouchard, M; Dobson, C M; Robinson, C V
2000-01-01
The self-assembly and aggregation of insulin molecules has been investigated by means of nanoflow electrospray mass spectrometry. Hexamers of insulin containing predominantly two, but up to four, Zn(2+) ions were observed in the gas phase when solutions at pH 4.0 were examined. At pH 3.3, in the absence of Zn(2+), dimers and tetramers are observed. Spectra obtained from solutions of insulin at millimolar concentrations at pH 2.0, conditions under which insulin is known to aggregate in solution, showed signals from a range of higher oligomers. Clusters containing up to 12 molecules could be detected in the gas phase. Hydrogen exchange measurements show that in solution these higher oligomers are in rapid equilibrium with monomeric insulin. At elevated temperatures, under conditions where insulin rapidly forms amyloid fibrils, the concentration of soluble higher oligomers was found to decrease with time yielding insoluble high molecular weight aggregates and then fibrils. The fibrils formed were examined by electron microscopy and the results show that the amorphous aggregates formed initially are converted to twisted, unbranched fibrils containing several protofilaments. Fourier transform infrared spectroscopy shows that both the soluble form of insulin and the initial aggregates are predominantly helical, but that formation of beta-sheet structure occurs simultaneously with the appearance of well-defined fibrils. PMID:10920035
Fluorophotometric measurement of the buffering action of human tears in vivo.
Yamada, M; Kawai, M; Mochizuki, H; Hata, Y; Mashima, Y
1998-10-01
The buffering action of human tears is thought to be important to keep its pH constant. We measured the change in pH in the precorneal tear film in vivo when the acidic solution is challenged, using a fluorophotometric technique. Twelve eyes from 6 healthy subjects were entered in this study. Each subject was pretreated with either one drop of 0.4% oxybuprocaine for once (light anesthesia), three times (deep anesthesia), or none (controls). The measurement was initiated by instilling 20 microl of 0.067 M phosphate buffer at pH 5.5 containing 2 mM bis-carboxyethyl-carboxyfluorescein free acid, a pH sensitive dye, into the subject's eye. The pH was determined by the ratio of fluorescent intensities at two excitation wavelengths (490 and 430 nm). pH recovery time (PHRT) as defined by the time required for pH to reach 95% of pH at equilibrium was used for the marker of tear buffering action. Tear turnover rate was also determined using the fluorescent decay curve at 430 nm, which was independent of pH, but dependent on dye concentration. Immediately after the instillation, the pH value in the tear film was around 6.0-6.5 in all cases. The tear film rapidly became more alkaline, reaching its normal value in 2.3 +/- 0.5 min in untreated eyes. The pretreatment with 0.4% oxybuprocaine retarded the neutralization process. A single regression analysis revealed that the PHRT had a significant negative correlation with the tear turnover rate (r = -0.78). Our results suggest that the neutralization process of tears largely depends on the tear turnover rate. The buffering action of tears in vivo consists of the tear turnover as well as its chemical buffering capacity.
NASA Astrophysics Data System (ADS)
Misran, E.; Bani, O.; Situmeang, E. M.; Purba, A. S.
2018-02-01
The effort to remove methylene blue in artificial solution had been conducted using adsorption process. The abundant banana stem waste was utilized as activated carbon precursor. This study aimed to analyse the influence of solution pH to removal efficiency of methylene blue using activated carbon from banana stem as adsorbent. Activated carbon from banana stem was obtained by chemical activation using H3PO4 solution. Proximate analysis result showed that the activated carbon has 47.22% of fixed carbon. This value exhibited that banana stem was a potential adsorbent precursor. Methylene blue solutions were prepared at initial concentration of 50 ppm. The influence of solution pH was investigated with the use of 0.2 g adsorbent for 100 mL dye solution. The adsorption was conducted using shaker with at a constant rate of 100 rpm at room temperature for 90 minutes. The results showed that solution pH influenced the adsorption. The activated carbon from banana stem demonstrated satisfying performance since removal efficiencies of methylene blue were higher than 99%.
Biosorption of cadmium and chromium in duckweed Wolffia globosa.
Upatham, E Suchart; Boonyapookana, Benjaporn; Kruatrachue, Maleeya; Pokethitiyook, Prayad; Parkpoomkamol, Krisna
2002-01-01
The biosorption of cadmium (Cd) and chromium (Cr) by using dried Wolffia globosa biomass were investigated using batch technique. The effects of concentration and pH solution on the adsorption isotherm were measured by determining the adsorption isotherm at initial metal concentrations from 10 to 400 mg/L and pH 4 to 7 for Cd, and pH 1.5 to 6 for Cr. The adsorption equilibria were found to follow Langmuir models. The maximum adsorption capacity (Xm) at pH 7 in W. globosa-Cd system was estimated to be 80.7 mg/g, while the maximum removal achieved at pH 4, pH 5, and pH 6 were 35.1, 48.8, and 65.4 mg/g, respectively. The Xm at pH 1.5 in W. globosa--Cr system was estimated to be 73.5 mg/g, while the maximum removal achieved at pH 3, pH 5, and pH 6 were 47.4, 33.1, and 12.9 mg/g, respectively. The effects of contact times on Cd and Cr sorption indicated that they were absorbed rapidly and more efficiently at lower concentrations.
NASA Astrophysics Data System (ADS)
Butler, Thomas M.; MacCraith, Brian D.; McDonagh, Colette M.
1995-09-01
The sol-gel process has been used to entrap pH indicators in porous glass coatings for sensor applications. This sensor is based on evanescent wave absorption using an unclad optical fiber dipcoated with the pH sensitive coating. The entrapped pH indicators show a broadening of the pH range with respect to the behavior in solution giving accurate measurement over three pH units when one indicator is used (bromophenol blue) and over six pH units (pH 3-9) when two indicators are used (bromophenol blue and bromocresol purple). The response of the pH sensor was monitored by measuring absorption at 590 nm referenced against a nonabsorbing region of the spectrum. This enabled the use of LED sources together with low cost photodiodes. The sensor displayed short response time and good repeatability. The thickness and stability of the pH sensitive coatings can be influenced by modifying the composition of the starting sol mixture. The evanescent absorption, and hence the sensitivity of the sensor, can be increased by selectively launching higher order modes in the fiber. These issues together with a full sensor characterization will be reported.
McUmber, Aaron C; Randolph, Theodore W; Schwartz, Daniel K
2015-07-02
High-throughput single-molecule total internal reflection fluorescence microscopy was used to investigate the effects of pH and ionic strength on bovine serum albumin (BSA) adsorption, desorption, and interfacial diffusion at the aqueous-fused silica interface. At high pH and low ionic strength, negatively charged BSA adsorbed slowly to the negatively charged fused silica surface. At low pH and low ionic strength, where BSA was positively charged, or in solutions at higher ionic strength, adsorption was approximately 1000 times faster. Interestingly, neither surface residence times nor the interfacial diffusion coefficients of BSA were influenced by pH or ionic strength. These findings suggested that adsorption kinetics were dominated by energy barriers associated with electrostatic interactions, but once adsorbed, protein-surface interactions were dominated by short-range nonelectrostatic interactions. These results highlight the ability of single-molecule techniques to isolate elementary processes (e.g., adsorption and desorption) under steady-state conditions, which would be impossible to measure using ensemble-averaging methods.
Nair, Lakshmi S; Starnes, Trevor; Ko, Jia-Wei Kevin; Laurencin, Cato T
2007-12-01
Thermosetting polymers are attractive candidates for biomedical applications as noninvasive therapeutic delivery vehicles. In the present study, the feasibility of developing a neutral physiological temperature setting injectable formulation based on chitosan and an inorganic phosphate salt have been demonstrated. The in situ gelling system was developed by adding different concentrations of ammonium hydrogen phosphate (AHP) to chitosan solution. The resulting solutions have pH in the range of approximately 7-7.2. The gelling time of the chitosan-AHP solution was determined by incubating the solutions at 37 degrees C. Depending on the concentrations of AHP added, the gelling time varied from 5 min to 30 h at 37 degrees C. Addition of various diluents to chitosan-AHP solution did not significantly change the gelling time of the solutions. The gels were found to be cytocompatible as evidenced from in vitro cytocompatibility evaluation using MC3T3-E1 mouse osteoblast like cells. The feasibility of using the gels as a stem cell carrier vehicle as well as a macromolecular delivery vehicle has been demonstrated.
Daneshvar, N; Oladegaragoze, A; Djafarzadeh, N
2006-02-28
Electrocoagulation (EC) is one of the most effective techniques to remove color and organic pollutants from wastewater, which reduces the sludge generation. In this paper, electrocoagulation has been used for the removal of color from solutions containing C. I. Basic Red 46 (BR46) and C. I. Basic Blue 3 (BB3). These dyes are used in the wool and blanket factories for fiber dyeing. The effect of operational parameters such as current density, initial pH of the solution, time of electrolysis, initial dye concentration and solution conductivity were studied in an attempt to reach higher removal efficiency. The findings in this study shows that an increase in the current density up to 60-80 A m(-2) enhanced the color removal efficiency, the electrolysis time was 5 min and the range of pH was determined between 5.5 and 8.5 for two mentioned dye solutions. It was found that for, the initial concentration of dye in solutions should not be higher than 80 mg l(-1) in order to achieve a high color removal percentage. The optimum conductivity was found to be 8 mS cm(-1), which was adjusted using proper amount of NaCl with the dye concentration of 50 mg l(-1). Electrical energy consumption in the above conditions for the decolorization of the dye solutions containing BR46 and BB3 were 4.70 kWh(kgdye removed)(-1) and 7.57 kWh(kgdye removed)(-1), respectively. Also, during the EC process under the optimized conditions, the COD decreased by more than 75% and 99% in dye solutions containing BB3 and BR46, respectively.
Kim, Kwang-Wook; Kim, Yeon-Hwa; Lee, Se-yoon; Lee, Jae-Won; Joe, Kih-Soo; Lee, Eil-Hee; Kim, Jong-Seung; Song, Kyuseok; Song, Kee-Chan
2009-04-01
This work studied the dissolution of uranium dioxide and precipitation characteristics of uranyl ions in alkaline and acidic solutions depending on the presence of carbonate ions and H2O2 in the solutions at different pHs controlled by adding HNO3 or NaOH in the solution. The chemical structures of the precipitates generated in different conditions were evaluated and compared by using XRD, SEM, TG-DT, and IR analyses together. The sizes and forms of the precipitates in the solutions were evaluated, as well. The uranyl ions were precipitated in the various forms, depending on the solution pH and the presences of hydrogen peroxide and carbonate ions in the solution. In a 0.5 M Na2CO3 solution with H2O2, where the uranyl ions formed mixed uranyl peroxy-carbonato complexes, the uranyl ions were precipitated as a uranium peroxide of UO4(H20)4 at pH 3-4, and precipitated as a clarkeite of Na2U2Ox(OH)y(H2O)z above pH 13. In the same carbonate solution without H2O2, where the uranyl ions formed uranyl tris-carbonato complex, the uranyl ions were observed to be precipitated as a different form of clarkeite above pH 13. The precipitate of uranyl ions in a nitrate solution without carbonate ions and H2O2 at a high pH were studied together to compare the precipitate forms in the carbonate solutions.
NASA Astrophysics Data System (ADS)
Ghaedi, Mehrorang; Tavallali, Hossein; Sharifi, Mahdi; Kokhdan, Syamak Nasiri; Asghari, Alireza
2012-02-01
In this research, the potential applicability of activated carbon prepared from Myrtus communis (AC-MC) and pomegranate (AC-PG) as useful adsorbents for the removal of Congo red (CR) from aqueous solutions in batch method was investigated. The effects of pH, contact time, agitation time and amount of adsorbents on removal percentage of Congo red on both adsorbents were examined. Increase in pH up to 6 for AC-MC and pH 7 for AC-PG increase the adsorption percentage (capacity) and reach equilibrium within 30 min of contact time. Fitting the experimental data to conventional isotherm models like Freundlich, Langmuir, Tempkin and Dubinin-Radushkevich show that the experimental data fitted very well to the Freundlich isotherm for AC-MC and Langmuir isotherm for AC-PG. Fitting the experimental data to different kinetic models such as pseudo first-order, pseudo second-order, Elovich and intraparticle diffusion mechanism showed the applicability of a pseudo second-order with involvement of intraparticle diffusion model for interpretation of experimental data for both adsorbents. The adsorption capacity of AC-PG and AC-MC for the removal of CR was found to be 19.231 and 10 mg g -1. These results clearly indicate the efficiency of adsorbents as a low cost adsorbent for treatment of wastewater containing CR.
Ghaedi, Mehrorang; Tavallali, Hossein; Sharifi, Mahdi; Kokhdan, Syamak Nasiri; Asghari, Alireza
2012-02-01
In this research, the potential applicability of activated carbon prepared from Myrtus communis (AC-MC) and pomegranate (AC-PG) as useful adsorbents for the removal of Congo red (CR) from aqueous solutions in batch method was investigated. The effects of pH, contact time, agitation time and amount of adsorbents on removal percentage of Congo red on both adsorbents were examined. Increase in pH up to 6 for AC-MC and pH 7 for AC-PG increase the adsorption percentage (capacity) and reach equilibrium within 30 min of contact time. Fitting the experimental data to conventional isotherm models like Freundlich, Langmuir, Tempkin and Dubinin-Radushkevich show that the experimental data fitted very well to the Freundlich isotherm for AC-MC and Langmuir isotherm for AC-PG. Fitting the experimental data to different kinetic models such as pseudo first-order, pseudo second-order, Elovich and intraparticle diffusion mechanism showed the applicability of a pseudo second-order with involvement of intraparticle diffusion model for interpretation of experimental data for both adsorbents. The adsorption capacity of AC-PG and AC-MC for the removal of CR was found to be 19.231 and 10 mg g(-1). These results clearly indicate the efficiency of adsorbents as a low cost adsorbent for treatment of wastewater containing CR. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steefel, Carl; Hausrath, E.M.; Navarre-Sitchler, A.K.
2008-03-15
Where Martian rocks have been exposed to liquid water, chemistry versus depth profiles could elucidate both Martian climate history and potential for life. The persistence of primary minerals in weathered profiles constrains the exposure time to liquid water: on Earth, mineral persistence times range from {approx}10 ka (olivine) to {approx}250 ka (glass) to {approx}1Ma (pyroxene) to {approx}5Ma (plagioclase). Such persistence times suggest mineral persistence minima on Mars. However, Martian solutions may have been more acidic than on Earth. Relative mineral weathering rates observed for basalt in Svalbard (Norway) and Costa Rica demonstrate that laboratory pH trends can be used tomore » estimate exposure to liquid water both qualitatively (mineral absence or presence) and quantitatively (using reactive transport models). Qualitatively, if the Martian solution pH > {approx}2, glass should persist longer than olivine; therefore, persistence of glass may be a pH-indicator. With evidence for the pH of weathering, the reactive transport code CrunchFlow can quantitatively calculate the minimum duration of exposure to liquid water consistent with a chemical profile. For the profile measured on the surface of Humphrey in Gusev Crater, the minimum exposure time is 22 ka. If correct, this estimate is consistent with short-term, episodic alteration accompanied by ongoing surface erosion. More of these depth profiles should be measured to illuminate the weathering history of Mars.« less
Online Monitoring of Methanol Electro-Oxidation Reactions by Ambient Mass Spectrometry
NASA Astrophysics Data System (ADS)
Cheng, Si; Wu, Qiuhua; Dewald, Howard D.; Chen, Hao
2017-06-01
Online detection of methanol electro-oxidation reaction products [e.g., formaldehyde (HCHO)] by mass spectrometry (MS) is challenging, owing to the high salt content and extreme pH of the electrolyte solution as well as the difficulty in ionizing the reaction products. Herein we present an online ambient mass spectrometric approach for analyzing HCHO generated from methanol electro-oxidation, taking the advantage of high salt tolerance of desorption electrospray ionization mass spectrometry (DESI-MS). It was found that HCHO can be detected as PhNHNH+=CH2 ( m/z 121) by DESI after online derivatization with PhNHNH2. With this approach, the analysis of HCHO from methanol electro-oxidation by MS was carried out not only in acidic condition but also in alkaline media for the first time. Efficiencies of different electrodes for methanol oxidation at different pHs were also evaluated. Our results show that Au electrode produces more HCHO than Pt-based electrodes at alkaline pH, while the latter have higher yields at acidic solution. The presented methodology would be of great value for elucidating fuel cell reaction mechanisms and for screening ideal fuel cell electrode materials. [Figure not available: see fulltext.
Janyasuthiwong, Suthee; Phiri, Sheila M; Kijjanapanich, Pimluck; Rene, Eldon R; Esposito, Giovanni; Lens, Piet N L
2015-01-01
The use of agricultural wastes (groundnut shell, orange and banana peel, rice husk, coconut husk and Wawa tree saw dust) as potential cost-effective adsorbent for heavy metal removal from wastewater was evaluated. The effect of pH (2.0-6.0), adsorbent dosage (0.6-2.2 g), contact time (10-130 min) and initial concentration (Pb: 5-105 mg/L, Cu and Zn: 2.5-52.7 mg/L) on the metal removal efficiency and uptake capacity were investigated using response surface methodology to optimize the process conditions. Groundnut shell showed a high potential to remove Cu, Pb and Zn from synthetic wastewater. The highest removal efficiencies with groundnut as the adsorbent were 85% at pH 5.0 for Cu and 98% at pH 3.0 for Pb and Zn. The optimum conditions obtained were 2.5 g adsorbent with 40.7 mg/L Cu at pH 4.4 and 64 min contact time, 2.5 g adsorbent with 196.1 mg/L Pb at pH 5.6 and 60 min contact time and 3.1 g adsorbent with 70.2 mg/L Zn at pH 4.3 and 50 min contact time, for Cu, Pb and Zn, respectively. The regeneration of the groundnut shell was possible for a maximum of three cycles using 0.2 M HCl as the desorbing solution without any significant change in the adsorbing efficiency.
Moreno-Piraján, Juan Carlos; Blanco, Diego; Giraldo, Liliana
2012-01-01
An activated carbon, Carbochem(TM)-PS230, was modified by chemical and thermal treatment in flow of H(2), in order to evaluate the influence of the activated carbon chemical characteristics in the adsorption of the catechol. The catechol adsorption in aqueous solution was studied along with the effect of the pH solution in the adsorption process of modified activated carbons and the variation of immersion enthalpy of activated carbons in the aqueous solutions of catechol. The interaction solid-solution is characterized by adsorption isotherms analysis, at 298 K and pH 7, 9 and 11 in order to evaluate the adsorption value above and below that of the catechol pK(a). The adsorption capacity of carbons increases when the solution pH decreases. The retained amount increases slightly in the reduced carbon to maximum adsorption pH and diminishes in the oxidized carbon. Similar conclusions are obtained from the immersion enthalpies, whose values increase with the solute quantity retained. In granular activated carbon (CAG), the immersion enthalpies obtained are between 21.5 and 45.7 J·g(-1) for catechol aqueous solutions in a range of 20 at 1500 mg·L(-1).
Moreno-Piraján, Juan Carlos; Blanco, Diego; Giraldo, Liliana
2012-01-01
An activated carbon, CarbochemTM—PS230, was modified by chemical and thermal treatment in flow of H2, in order to evaluate the influence of the activated carbon chemical characteristics in the adsorption of the catechol. The catechol adsorption in aqueous solution was studied along with the effect of the pH solution in the adsorption process of modified activated carbons and the variation of immersion enthalpy of activated carbons in the aqueous solutions of catechol. The interaction solid-solution is characterized by adsorption isotherms analysis, at 298 K and pH 7, 9 and 11 in order to evaluate the adsorption value above and below that of the catechol pKa. The adsorption capacity of carbons increases when the solution pH decreases. The retained amount increases slightly in the reduced carbon to maximum adsorption pH and diminishes in the oxidized carbon. Similar conclusions are obtained from the immersion enthalpies, whose values increase with the solute quantity retained. In granular activated carbon (CAG), the immersion enthalpies obtained are between 21.5 and 45.7 J·g−1 for catechol aqueous solutions in a range of 20 at 1500 mg·L−1. PMID:22312237
Sundaramurthi, Prakash; Suryanarayanan, Raj
2011-04-01
Selective crystallization of buffer components in frozen solutions is known to cause pronounced pH shifts. Our objective was to study the crystallization behavior and the consequent pH shift in frozen aqueous carboxylic acid buffers. Aqueous carboxylic acid buffers were cooled to -25°C and the pH of the solution was measured as a function of temperature. The thermal behavior of solutions during freezing and thawing was investigated by differential scanning calorimetry. The crystallized phases in frozen solution were identified by X-ray diffractometry. The malate buffer system was robust with no evidence of buffer component crystallization and hence negligible pH shift. In the citrate and tartarate systems, at initial pH
The impact of pH and calcium on the uptake of fluoride by tea plants (Camellia sinensis L.).
Ruan, Jianyun; Ma, Lifeng; Shi, Yuanzhi; Han, Wenyan
2004-01-01
Tea plants (Camellia sinensis L.) accumulate large amounts of fluoride (F) from soils containing normal F concentrations. The present experiments examined the effects of pH and Ca on F uptake by this accumulating plant species. The effect of pH was assessed in two experiments, one using uptake solutions with different pHs, and the other using lime, as CaO, applied to the soil. The effect of Ca was examined by analysing F concentrations in plants supplied with varying amounts of Ca, as Ca(NO3)2, either in uptake solutions or through the soil. F uptake was highest at solution pH 5.5, and significantly lower at pH 4.0. In the soil experiment, leaf F decreased linearly with the amounts of lime, which raised the soil pH progressively from 4.32 to 4.91, 5.43, 5.89 and, finally, 6.55. Liming increased the water-soluble F content of the soil. Including Ca in the uptake solution or adding Ca to soil significantly decreased leaf F concentrations. The distribution pattern of F in tea plants was not altered by Ca treatment, with most F being allocated to leaves. The activity of F- in the uptake solution was unaffected and water-soluble F in the soil was sometimes increased by added Ca. F uptake by tea plants, which are inherently able to accumulate large quantities of F, was affected both by pH and by Ca levels in the medium. The reduced F uptake following Ca application appeared not to be due simply to the precipitation of CaF2 in solution and soil or to the complexing of Ca and F in roots, although these factors cannot be dismissed. It was more likely due to the effect of Ca on the properties of cell wall or membrane permeability in the solution experiments, and to alteration of F speciations and their quantities in soil solutions following Ca application.
Jiang, Chao; Garg, Shikha; Waite, T David
2015-12-15
Interactions of 1,4-hydroquinone with soluble iron species over a pH range of 3-5 in the air-saturated and partially deoxygenated solution are examined here. Our results show that 1,4-hydroquinone reduces Fe(III) in acidic conditions, generating semiquinone radicals (Q(•-)) that can oxidize Fe(II) back to Fe(III). The oxidation rate of Fe(II) by Q(•-)increases with increase in pH due to the speciation change of Q(•-) with its deprotonated form (Q(•-)) oxidizing Fe(II) more rapidly than the protonated form (HQ(•)). Although the oxygenation of Fe(II) is negligible at pH < 5, O2 still plays an important role in iron redox transformation by rapidly oxidizing Q(•-) to form benzoquinone (Q). A kinetic model is developed to describe the transformation of quinone and iron under all experimental conditions. The results obtained here are compared with those obtained in our previous studies of iron-Suwannee River fulvic acid (SRFA) interactions in acidic solutions and support the hypothesis that hydroquinone moieties can reduce Fe(III) in natural waters. However, the semiquinone radicals generated in pure hydroquinone solution are rapidly oxidized by dioxygen, while the semiquinone radicals generated in SRFA solution are resistant to oxidation by dioxygen, with the result that steady-state semiquinone concentrations in SRFA solutions are 2-3 orders of magnitude greater than in solutions of 1,4-hydroquinone. As a result, semiquinone moieties in SRFA play a much more important role in iron redox transformations than is the case in solutions of simple quinones such as 1,4-hydroquinone. This difference in the steady-state concentration of semiquinone species has a dramatic effect on the cycling of iron between the +II and +III oxidation states, with iron turnover frequencies in solutions containing SRFA being 10-20 times higher than those observed in solutions of 1,4-hydroquinone.
Wang, Yong-Chun; Lin, Cong-Bin; Su, Jian-Jia; Ru, Ying-Ming; Wu, Qiao; Chen, Zhao-Bin; Mao, Bing-Wei; Tian, Zhao-Wu
2011-06-15
In this paper, we present an electrochemically driven large amplitude pH alteration method based on a serial electrolytic cell involving a hydrogen permeable bifacial working electrode such as Pd thin foil. The method allows solution pH to be changed periodically up to ±4~5 units without additional alteration of concentration and/or composition of the system. Application to the acid-base driven cyclic denaturation and renaturation of 290 bp DNA fragments is successfully demonstrated with in situ real-time UV spectroscopic characterization. Electrophoretic analysis confirms that the denaturation and renaturation processes are reversible without degradation of the DNA. The serial electrolytic cell based electrochemical pH alteration method presented in this work would promote investigations of a wide variety of potential-dependent processes and techniques.
On the Preparation of Buffer Solutions.
ERIC Educational Resources Information Center
Thomson, Bruce M.; Kessick, Michael A.
1981-01-01
Presents a method, suitable for use on programmable calculators, which allows calculation of the pH and ionic strength (I) of a mixed solution of salts of an acid or amounts necessary to produce a solution of a particular pH and I. Includes limitations when using the calculations described. (SK)
USDA-ARS?s Scientific Manuscript database
Selenite Se(IV) and selenate Se(VI) selenium adsorption behavior was investigated on gibbsite as a function of solution pH and solution ionic strength. Adsorption of both Se redox states decreased with increasing solution pH. Electrophoretic mobility measurements showed downward shifts in point of...
Veisi, Farzaneh; Zazouli, Mohammad Ali; Ebrahimzadeh, Mohammad Ali; Charati, Jamshid Yazdani; Dezfoli, Amin Shiralizadeh
2016-11-01
The photocatalytic degradation of furfural in aqueous solution was investigated using N-doped titanium dioxide nanoparticles under sunlight and ultraviolet radiation (N-TiO 2 /Sun and N-TiO 2 /UV) in a lab-scale batch photoreactor. The N-TiO 2 nanoparticles prepared using a sol-gel method were characterized using XRD, X-ray photoelectron spectroscopy (XPS), and SEM analyses. Using HPLC to monitor the furfural concentration, the effect of catalyst dosage, contact time, initial solution pH, initial furfural concentration, and sunlight or ultraviolet radiation on the degradation efficiency was studied. The efficiency of furfural removal was found to increase with increased reaction time, nanoparticle loading, and pH for both processes, whereas the efficiency decreased with increased furfural concentration. The maximum removal efficiencies for the N-TiO 2 /UV and N-TiO 2 /Sun processes were 97 and 78 %, respectively, whereas the mean removal efficiencies were 80.71 ± 2.08 % and 62.85 ± 2.41 %, respectively. In general, the degradation and elimination rate of furfural using the N-TiO 2 /UV process was higher than that using the N-TiO 2 /Sun process.
Lead removal by Spirulina platensis biomass.
Al-Homaidan, Ali A; Al-Abbad, Aljawharah F; Al-Hazzani, Amal A; Al-Ghanayem, Abdullah A; Alabdullatif, Jamila A
2016-01-01
In this investigation, we report on the biosorption of Pb (II) from aqueous solutions by the nonliving biomass of the micro-alga (cyanobacterium) Spirulina platensis. Propagation of the micro-alga was carried out in outside oblong raceway ponds. The biomass was cleaned, dried and used for the investigation. The effects of pH, adsorbent dose, temperature, initial concentration of Pb (II), and contact time on the adsorption of lead by the dry biomass were studied. The experiments were carried out in 250 ml conical flasks containing 100 ml of test solutions using an orbital incubator at 150 rpm. Concentrations of the metal before and after the experiments were measured using Atomic Absorption Spectrophotometer. Very high levels of Pb (II) removal (>91%) were obtained. The optimum conditions for maximal adsorption by S. platensis were found to be pH 3; 2 g of adsorbent dose; incubation at 26°C; 100 mg/l of lead initial concentration and 60 minutes of contact time. The experimental data fitted well with Freundlich isotherm equation with R(2) values greater than 0.97. Based on our results, we recommend the utilization of S. platensis biomass for heavy metal removal from aqueous solutions.
Liu, Qing; Li, Qingrui; Han, Ting; Hu, Tingting; Zhang, Xuemei; Hu, Junhua; Hu, Hui; Tan, Wen
2017-09-01
Currently, all commercial available nebulized salbutamol in China is in its racemic form. It is known that only R-salbutamol (eutomer) has therapeutic effects, while S-salbutamol (distomer) may exacerbate asthma after chronic use. Therefore, it is an unmet clinical need to develop R-salbutamol as a nebulized product that is more convenient for young and old patients. In our study, a stable aerosol solution of R-salbutamol sulfate was established, and its antiasthmatic effects were confirmed. The decomposition rate and racemization effect of the R-salbutamol sulfate solution were evaluated over a pH range from 1 to 10 (except pH=7, 8) at 60°C. The aerodynamic particle size of the R-salbutamol sulfate solution and commercial RS-salbutamol sulfate solution were both tested in vitro by Next-Generation Impactor (NGI) in 5°C. Laser diffractometer was used to characterize the droplet-size distribution (DSD) of both solutions. We next conducted an in vivo animal study to document the antiasthmatic effect of R-salbutamol aerosol sulfate solution and determine the relationship to RS-salbutamol. The results showed that the R-salbutamol sulfate solution was more stable at pH 6. In vitro comparison studies indicated that there was no distribution difference between R-salbutamol sulfate solution and the commercial RS-salbutamol solution. The animal results showed that R-salbutamol was more potent than RS-salbutamol against the same dose of histamine challenge. Unlike commercial RS-salbutamol, which was acidified to a pH of 3.5 to extend bench life but may cause bronchoconstriction in asthmatic patients, the neutralized R-salbutamol solution was more suitable for clinic use.
Liang, Kunneng; Zhou, Han; Weir, Michael D; Bao, Chongyun; Reynolds, Mark A; Zhou, Xuedong; Li, Jiyao; Xu, Hockin H K
2017-07-01
Patients with dry mouth often have an acidic oral environment lacking saliva that provides calcium (Ca) and phosphate (P) ions. However, there has been no study on dentin remineralization by placing samples in an acidic solution without Ca and P ions. Previous studies used saliva-like solutions with neutral pH and Ca and P ions. Therefore, the objective of this study was to investigate a novel method of combining poly(amido amine) (PAMAM) with a composite of nanoparticles of amorphous calcium phosphate (NACP) on dentin remineralization in an acidic solution without Ca and P ions for the first time. Demineralized dentin specimens were tested into four groups: (1) dentin control, (2) dentin coated with PAMAM, (3) dentin with NACP nanocomposite, (4) dentin with PAMAM plus NACP composite. Specimens were treated with lactic acid at pH 4 without initial Ca and P ions for 21 days. Acid neutralization and Ca and P ion concentrations were measured. Dentin specimens were examined by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and hardness testing vs. remineralization efficacy. NACP composite had mechanical properties similar to commercial control composites (p>0.1). NACP composite neutralized acid and released Ca and P ions. PAMAM alone failed to induce dentin remineralization. NACP alone achieved mild remineralization and slightly increased dentin hardness at 21days (p>0.1). In contrast, the PAMAM+NACP nanocomposite method in acid solution without initial Ca and P ions greatly remineralized the pre-demineralized dentin, restoring its hardness to approach that of healthy dentin (p>0.1). Dentin remineralization via PAMAM+NACP in pH 4 acid without initial Ca and P ions was demonstrated for the first time, when conventional methods such as PAMAM did not work. The novel PAMAM+NACP nanocomposite method is promising to protect tooth structures, especially for patients with reduced saliva to inhibit caries. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Tor, Ali; Aydin, Mehmet Emin; Aydin, Senar; Tabakci, Mustafa; Beduk, Fatma
2013-11-15
An aminopropyl silica gel-immobilized calix[6]arene (C[6]APS) has been used for the removal of lindane from an aqueous solution in batch sorption technique. The C[6]APS was synthesized with p-tert-butylcalix[6]arene hexacarboxylate derivative and aminopropyl silica gel in the presence of N,N'-diisopropyl carbodiimide coupling reagent. The sorption study was carried out as functions of solution pH, contact time, initial lindane concentration, C[6]APS dosage and ionic strength of solution. The matrix effect of natural water samples on the sorption efficiency of C[6]APS was also investigated. Maximum lindane removal was obtained at a wide pH range of 2-8 and sorption equilibrium was achieved in 2h. The isotherm analysis indicated that the sorption data can be represented by both Langmuir and Freundlich isotherm models. Increasing ionic strength of the solutions increased the sorption efficiency and matrix of natural water samples had no effect on the sorption of lindane. By using multilinear regression model, regression equation was also developed to explain the effects of the experimental variables. Copyright © 2013 Elsevier B.V. All rights reserved.
Quaternized wood as sorbent for hexavalent chromium.
Low, K S; Lee, C K; Lee, C Y
2001-01-01
The potential of quaternized wood (QW) chips in removing hexavalent chromium from synthetic solution and chrome waste under both batch and continuous-flow conditions was investigated. Sorption was found to be dependent on pH, metal concentration, and temperature. QW chips provide higher sorption capacity and wider pH range compared with untreated wood chips. The equilibrium data could be fitted into the Langmuir isotherm model, and maximum sorption capacities were calculated to be 27.03 and 25.77 mg/g in synthetic chromate solution and chrome waste, respectively. The presence of sulfate in high concentration appeared to suppress the uptake of chromium by QW chips. Column studies showed that bed depth influenced the breakthrough time greatly whereas flow rate of influent had little effect on its sorption on the column.
NASA Astrophysics Data System (ADS)
Wiśniewska, Małgorzata; Chibowski, Stanisław; Urban, Teresa
2016-05-01
The adsorption mechanism of anionic polyacrylamide (PAM) on the nanozirconia surface was examined. The effects of solution pH, carboxyl groups content in macromolecules and anionic surfactant (sodium dodecyl sulfate-SDS) addition were determined. The more probable structure of polymer adsorption layer was characterized based on the data obtained from spectrophotometry, viscosimetry and potentiometric titration methods. The adsorbed amount of polymer, size of macromolecules in the solution and surface charge density of ZrO2 particles in the absence and presence of PAM were assessed, respectively. Analysis of these results indicated that the increase of solution pH and content of carboxyl groups in the polymeric chains lead to more expanded conformations of adsorbing macromolecules. As a result, the adsorption of anionic polyacrylamide decreased. The SDS presence caused the significant increase of PAM adsorbed amount at pH 3, whereas at pH 6 and 9 the surfactant addition resulted in reduction of polymer adsorption level.
Cravotta, C.A.
2008-01-01
Water-quality data for discharges from 140 abandoned mines in the Anthracite and Bituminous Coalfields of Pennsylvania reveal complex relations among the pH and dissolved solute concentrations that can be explained with geochemical equilibrium models. Observed values of pH ranged from 2.7 to 7.3 in the coal-mine discharges (CMD). Generally, flow rates were smaller and solute concentrations were greater for low-pH CMD samples; pH typically increased with flow rate. Although the frequency distribution of pH was similar for the anthracite and bituminous discharges, the bituminous discharges had smaller median flow rates; greater concentrations of SO4, Fe, Al, As, Cd, Cu, Ni and Sr; comparable concentrations of Mn, Cd, Zn and Se; and smaller concentrations of Ba and Pb than anthracite discharges with the same pH values. The observed relations between the pH and constituent concentrations can be attributed to (1) dilution of acidic water by near-neutral or alkaline ground water; (2) solubility control of Al, Fe, Mn, Ba and Sr by hydroxide, sulfate, and/or carbonate minerals; and (3) aqueous SO4-complexation and surface-complexation (adsorption) reactions. The formation of AlSO4+ and AlHSO42 + complexes adds to the total dissolved Al concentration at equilibrium with Al(OH)3 and/or Al hydroxysulfate phases and can account for 10-20 times greater concentrations of dissolved Al in SO4-laden bituminous discharges compared to anthracite discharges at pH of 5. Sulfate complexation can also account for 10-30 times greater concentrations of dissolved FeIII concentrations at equilibrium with Fe(OH)3 and/or schwertmannite (Fe8O8(OH)4.5(SO4)1.75) at pH of 3-5. In contrast, lower Ba concentrations in bituminous discharges indicate that elevated SO4 concentrations in these CMD sources could limit Ba concentrations by the precipitation of barite (BaSO4). Coprecipitation of Sr with barite could limit concentrations of this element. However, concentrations of dissolved Pb, Cu, Cd, Zn, and most other trace cations in CMD samples were orders of magnitude less than equilibrium with sulfate, carbonate, and/or hydroxide minerals. Surface complexation (adsorption) by hydrous ferric oxides (HFO) could account for the decreased concentrations of these divalent cations with increased pH. In contrast, increased concentrations of As and, to a lesser extent, Se with increased pH could result from the adsorption of these oxyanions by HFO at low pH and desorption at near-neutral pH. Hence, the solute concentrations in CMD and the purity of associated "ochres" formed in CMD settings are expected to vary with pH and aqueous SO4 concentration, with potential for elevated SO4, As and Se in ochres formed at low pH and elevated Cu, Cd, Pb and Zn in ochres formed at near-neutral pH. Elevated SO4 content of ochres could enhance the adsorption of cations at low pH, but decrease the adsorption of anions such as As. Such information on environmental processes that control element concentrations in aqueous samples and associated precipitates could be useful in the design of systems to reduce dissolved contaminant concentrations and/or to recover potentially valuable constituents in mine effluents.
INACTIVATION AND REACTIVATION OF B. MEGATHERIUM PHAGE
Northrop, John H.
1955-01-01
Preparation of Reversibly Inactivated (R.I.) Phage.— If B. megatherium phage (of any type, or in any stage of purification) is suspended in dilute salt solutions at pH 5–6, it is completely inactivated; i.e., it does not form plaques, or give rise to more phage when mixed with a sensitive organism (Northrop, 1954). The inactivation occurs when the phage is added to the dilute salt solution. If a suspension of the inactive phage in pH 7 peptone is titrated to pH 5 and allowed to stand, the activity gradually returns. The inactivation is therefore reversible. Properties of R.I. Phage.— The R.I. phage is adsorbed by sensitive cells at about the same rate as the active phage. It kills the cells, but no active phage is produced. The R.I. phage therefore has the properties of phage "ghosts" (Herriott, 1951) or of colicines (Gratia, 1925), or phage inactivated by ultraviolet light (Luria, 1947). The R.I. phage is sedimented in the centrifuge at the same rate as active phage. It is therefore about the same size as the active phage. The R.I. phage is most stable in pH 7, 5 per cent peptone, and may be kept in this solution for weeks at 0°C. The rate of digestion of R.I. phage by trypsin, chymotrypsin, or desoxyribonuclease is about the same as that of active phage (Northrop, 1955 a). Effect of Various Substances on the Formation of R.I. Phage.— There is an equilibrium between R.I. phage and active phage. The R.I. form is the stable one in dilute salt solution, pH 5 to 6.5 and at low temperature (<20°C.). At pH >6.5, in dilute salt solution, the R.I. phage changes to the active form. The cycle, active ⇌ inactive phage, may be repeated many times at 0°C. by changing the pH of the solution back and forth between pH 7 and pH 6. Irreversible inactivation is caused by distilled water, some heavy metals, concentrated urea or quanidine solutions, and by l-arginine. Reversible inactivation is prevented by all salts tested (except those causing irreversible inactivation, above). The concentration required to prevent R.I. is lower, the higher the valency of either the anion or cation. There are great differences, however, between salts of the same valency, so that the chemical nature as well as the valency is important. Peptone, urea, and the amino acids, tryptophan, leucine, isoleucine, methionine, asparagine, dl-cystine, valine, and phenylalanine, stabilize the system at pH 7, so that no change occurs if a mixture of R.I. and active phage is added to such solutions. The active phage remains active and the R.I. phage remains inactive. The R.I. phage in pH 7 peptone becomes active if the pH is changed to 5.0. This does not occur in solutions of urea or the amino acids which stabilize at pH 7.0. Kinetics of Reversible Inactivation.— The inactivation is too rapid, even at 0° to allow the determination of an accurate time-inactivation curve. The rate is independent of the phage concentration and is complete in a few seconds, even in very dilute suspensions containing <1 x 104 particles/ml. This result rules out any type of bimolecular reaction, or any precipitation or agglutination mechanism, since the minimum theoretical time for precipitation (or agglutination) of a suspension of particles in a concentration of only 1 x 104 per ml. would be about 300 days even though every collision were effective. Mechanism of Salt Reactivation.— Addition of varying concentrations of MgSO4 (or many other salts) to a suspension of either active or R.I. phage in 0.01 M, pH 6 acetate buffer results in the establishment of an equilibrium ratio for active/R.I. phage. The higher the concentration of salt, the larger proportion of the phage is active. The results, with MgSO4, are in quantitative agreement with the following reaction: See PDF for Equation Effect of Temperature.— The rate of inactivation is too rapid to be measured with any accuracy, even at 0°C. The rate of reactivation in pH 5 peptone, at 0 and 10°, was measured and found to have a temperature coefficient Q 10 = 1.5 corresponding to a value of E (Arrhenius' constant) of 6500 cal. mole–1. This agrees very well with the temperature coefficient for the reactivation of denatured soy bean trypsin inhibitor (Kunitz, 1948). The equilibrium between R.I. and active phage is shifted toward the active side by lowering the temperature. The ratio R.I.P./AP is 4.7 at 15° and 2.8 at 2°. This corresponds to a change in free energy of –600 cal. mole–1 and a heat of reaction of 11,000. These values are much lower than the comparative one for trypsin (Anson and Mirsky, 1934 a) or soy bean trypsin inhibitor (Kunitz, 1948). Neither the inactivation nor the reactivation reactions are affected by light. The results in general indicate that there is an equilibrium between active and R.I. phage. The R.I. phage is probably an intermediate step in the formation of inactive phage. The equilibrium is shifted to the active side by lowering the temperature, adjusting the pH to 7–8 (except in the presence of high concentrations of peptone), raising the salt concentration, or increasing the valency of the ions present. The reaction may be represented by the following: See PDF for Equation The assumption that the active/R.I. phage equilibrium represents an example of native/denatured protein equilibrium predicts all the results qualitatively. Quantitatively, however, it fails to predict the relative rate of digestion of the two forms by trypsin or chymotrypsin, and also the effect of temperature on the equilibrium. PMID:13271723
Complexing agents and pH influence on chemical durability of type I moulded glass containers.
Biavati, Alberto; Poncini, Michele; Ferrarini, Arianna; Favaro, Nicola; Scarpa, Martina; Vallotto, Marta
2017-06-16
Among the factors that affect the glass surface chemical durability, pH and complexing agents presence in aqueous solution have the main role (1). Glass surface attack can be also related to the delamination issue with glass particles appearance in the pharmaceutical preparation. A few methods to check for glass containers delamination propensity and some control guidelines have been proposed (2,3). The present study emphasizes the possible synergy between a few complexing agents with pH on the borosilicate glass chemical durability. Hydrolytic attack was performed in small volume 23 ml type I glass containers autoclaved according to EP or USP for 1 hour at 121°C, in order to enhance the chemical attack due to time, temperature and the unfavourable surface/volume ratio. 0,048 M or 0.024 M (moles/liter) solutions of the acids citric, glutaric, acetic, EDTA (ethylenediaminetetraacetic acid) and sodium phosphate with water for comparison, were used for the trials. The pH was adjusted ± 0,05 units at fixed values 5,5-6,6-7-7,4-8-9 by LiOH diluted solution. Since silicon is the main glass network former, silicon release into the attack solutions was chosen as the main index of the glass surface attack and analysed by ICPAES. The work was completed by the analysis of the silicon release in the worst attack conditions, of moulded glass, soda lime type II and tubing borosilicate glass vials to compare different glass compositions and forming technologies. Surface analysis by SEM was finally performed to check for the surface status after the worst chemical attack condition by citric acid. Copyright © 2017, Parenteral Drug Association.
de Melo da Silva, Lucas; Gozzi, Fábio; Sirés, Ignasi; Brillas, Enric; de Oliveira, Silvio Cesar; Machulek, Amilcar
2018-08-01
Electro-oxidation with electrogenerated H 2 O 2 (EO-H 2 O 2 ) was applied to treat acidic aqueous solutions of 4-aminoantipyrine (4-AA), a persistent drug metabolite of dipyrone, in sulfate medium. Trials were made using a boron-doped diamond anode in the presence of H 2 O 2 electrogenerated on site. A 2 4 central composite design (CCD) was employed to evaluate the effect of four independent variables, namely current density (j), pH, 4-AA concentration and electrolysis time, on the percentages of degradation and mineralization, as well as on mineralization current efficiency (MCE). Predicted responses agreed with observed values, showing linear trendlines with good R 2 and R 2 adj values. The degradation was optimum at j=77.5mAcm -2 , pH3.5 and 62.5mgL -1 4-AA, leading to 63% and 99% removal after 3 and 7min, respectively. For those solutions, the largest mineralization was found at j=77.5mAcm -2 , attaining 45% abatement at 175min. Low MCE values were obtained in all electrolyses. An initial route for 4-AA degradation is proposed based on one dimer and eleven aromatic and aliphatic intermediates detected in the treated solutions at pH3.5 by LC-MS. The initial 62.5mgL -1 solution at pH3.5 presented acute toxicity on Artemia salina larvae, with LC 50 =13.6mgL -1 , being substantially reduced after 3 and 7min of EO-H 2 O 2 at j=77.5mAcm -2 due to the formation of less toxic derivatives. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhu, Wenfeng; Li, Yiming; Wang, Jinling; Ortiz de Montellano, Paul R; La Mar, Gerd N
2006-01-01
Solution proton NMR has been used here to show that, as either the high-spin ferric, protohemin (PH) substrate complex at neutral pH, or the low-spin ferric, cyanide-inhibited PH substrate complex, the active site electronic and molecular structure of the 233- and 265-residue recombinant constructs of human heme oxygenase-1, hHO, are essentially indistinguishable. It is shown, moreover, that the equilibrium PH orientational isomerism about the alpha,gamma-meso axis is 1:1 in the water-ligated, resting-state complex, but changes to a 4:1 equilibrium ratio as the cyanide-inhibited complex, with the minor species in solution corresponding to the only one found in crystals. The introduction of significant PH orientational preference in the cyanide over the aquo complex is rationalized by the crystallographic observation for the same H2O and CN ligated complexes of rat heme oxygenase (rHO), where the steric tilt of the Fe-CN unit resulted in a approximately 1 A transition of PH into the hydrophobic interior, and stronger interaction of the vinyls with the HO matrix [M. Sugishima, H. Sakamoto, M. Noguchi, K. Fukugama, Biochemistry 42 (2003) 9898-9905]. 1H NMR spectra of the cyanide-inhibited PH complex are the most used, and most useful, for determining the distribution of orientational isomerism for PH in complexes of HO. Hence, it is imperative that the time-course of the spectra after sample preparation be considered in order to reach conclusions that relate isomeric seating of the heme with variable isomeric biliverdin products. The natural orientational isomerism of PH leads to spectral congestion that has prompted the use of a synthetic, twofold symmetric substrate, 2,4-dimethyldeuterohemin, DMDH. While the hyperfine shift pattern for non-ligated residues are very similar and are consistent with largely conserved molecular structure with the alternate substrates, the steric tilt of the Fe-CN vector towards the protein interior, as determined by the orientation of the major magnetic axes, is 2 degrees smaller for DMDH than PH, and is rationalized by the substrate translating even further into the hydrophobic interior in the cyanide complex when the bulky vinyl groups are replaced by methyl groups.
Does Warming a Lysozyme Solution Cook Ones Data?
NASA Technical Reports Server (NTRS)
Pusey, Marc; Burke, Michael; Judge, Russell
2000-01-01
Chicken egg white lysozyme has a well characterized thermally driven phase transition. Between pH 4.0 and 5.2, the transition temperature, as defined by the point where the tetragonal and orthorhombic solubility are equal, is a function of the pH, salt (precipitant) type and concentration, and most likely of the buffer concentration as well. This phase transition can be carried out with protein solution alone, prior to the initiation of the crystallization process. We have now measured the kinetics of this process and investigated its reversibility. An aliquot of a stock protein solution is held at a given temperature, and at periodic intervals used to set up batch crystallization experiments. The batch solutions were incubated at 20 C until macroscopic crystals were obtained, at which point the number of crystals in each well were counted. The transition effects increased with temperature, slowly falling off at 30 C with a half time (time to approx. 1/2 the t = 0 number of crystals) of approx. 5 hours, and an estimated half time of approx. 0.5 hours at 43 C. Further, the process was not reversible by simple cooling. After holding a lysozyme solution at 37 C (prior to addition of precipitant) for 16 hours, then cooling and holding it at 4 C, no return to the pre-warmed nucleation kinetics are observed after at least 4 weeks. Thus every thermal excursion above the phase transition point results in a further decrease in the nucleation rate of that solution, the extent being a function of the time and temperature. Orthorhombic lysozyme crystals apparently do not undergo the flow-induced growth cessation of tetragonal lysozyme crystals. We have previously shown that putting the protein in the orthorhombic form does not affect the averaged face growth kinetics, only nucleation, for tetragonal crystals. We may be able to use this differential behavior to elucidate how flow affects tile lysozyme crystal growth process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrao, Alcidio.; Araujo, Jose Adroaldo de; Franca Junior, J.M.
This paper describes a technique for the production of nuclear grade ammonium diuranate (ADU) using uranyl sulfate solutions obtained as eluate from the ion exchange (strong cationic resin) purification of uranium, by precipitation with NH{sub 3} gas. The precipitation of ADU by direct introduction of NH{sub 3} gas into acid uranyl sulfate solution has as consequence a high coprecipitation of sulfate ion, reaching ratios as high as 10 to 14% SO{sub 4}/ADU. To overcome this serious inconvenience, the reverse order of addition of reagents was studied, the ADU precipitation being done in such a way that the pH of themore » mixture was kept higher than 6 during the whole precipitation. This modification, in conjunction with the adjustment of other precipitation parameters, like temperature, precipitation time, aging time, concentration of uranium in uranyl sulfate and pH, allowed a sucessful precipitation of ADU with low sulfate content. The technique was applied at pilot plant scale, using batch and continuous precipitation, in both cases the obtained ADU was low in sulfate.« less
Papaya Seeds as A Low-Cost Sorbent for Removing Cr(VI) from The Aqueous Solution
NASA Astrophysics Data System (ADS)
Rahmawati, Atik; Marwoto, Putut; Karunia Z, Anita
2016-08-01
The presence of chromium (VI) contaminants and their toxicity in aqueous streams important environmental problems. Adsorption is one of the effective techniques that can be used for removing metal from wastewater. This research was initiated by preparing sorbent from papaya seeds and determining its functional group contents by using FT-IR. The adsorption process was carried out in a batch method. The study of adsorption aspects involved the pH, initial Cr (VI) concentration and contact time between Cr (VI) and sorbent. FT IR analysis results showed that the main functional groups are carbonyl, hydroxyl, and carboxylic. It was also found that the effective pH for Cr (VI) uptake is 2.0 and increasing contact time would increase the Cr (VI) uptake. In addition, the equilibrium was reached after 40 minutes interaction and the increase of initial chromium (VI) concentration would increase the sorbent uptake percentage. All these results indicated that papaya seed is a potential sorbent for removing Cr (VI) from aqueous solutions.
Sarangapani, Prasad S; Weaver, Justin; Parupudi, Arun; Besong, Tabot M D; Adams, Gary G; Harding, Stephen E; Manikwar, Prakash; Castellanos, Maria M; Bishop, Steven M; Pathak, Jai A
2016-12-01
The role of antibody structure (conformation) in solution rheology is probed. It is demonstrated here that pH-dependent changes in the tertiary structure of 2 mAb solutions lead to viscoelasticity and not merely a shear viscosity (η) increase. Steady shear flow curves on mAb solutions are reported over broad pH (3.0 ≤ pH ≤ 8.7) and concentration (2 mg/mL ≤ c ≤ 120 mg/mL) ranges to comprehensively characterize their rheology. Results are interpreted using size exclusion chromatography, differential scanning calorimetry, analytical ultracentrifugation, near-UV circular dichroism, and dynamic light scattering. Changes in tertiary structure with concentration lead to elastic yield stress and increased solution viscosity in solution of "mAb1." These findings are supported by dynamic light scattering and differential scanning calorimetry, which show increased hydrodynamic radius of mAb1 at low pH and a reduced melting temperature T m , respectively. Conversely, another molecule at 120 mg/mL solution concentration is a strong viscoelastic gel due to perturbed tertiary structure (seen in circular dichroism) at pH 3.0, but the same molecule responds as a viscous liquid due to reversible self-association at pH 7.4 (verified by analytical ultracentrifugation). Both protein-protein interactions and structural perturbations govern pH-dependent viscoelasticity of mAb solutions. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
Ward, W Kenneth; Massoud, Ryan G; Szybala, Cory J; Engle, Julia M; El Youssef, Joseph; Carroll, Julie M; Roberts, Charles T; DiMarchi, Richard D
2010-01-01
Background For automated prevention of hypoglycemia, there is a need for glucagon (or an analog) to be sufficiently stable so that it can be indwelled in a portable pump for at least 3 days. However, under some conditions, solutions of glucagon can form amyloid fibrils. Currently, the usage instructions for commercially available glucagon allow only for its immediate use. Methods In NIH 3T3 fibroblasts, we tested amyloid formation and cytotoxicity of solutions of native glucagon and the glucagon analog MAR-D28 after aging under different conditions for 5 days. In addition, aged native glucagon was subjected to size-exclusion chromatography (SEC). We also studied whether subcutaneous aged Novo Nordisk GlucaGen® would have normal bioactivity in octreotide-treated, anesthetized, nondiabetic pigs. Results We found no evidence of cytotoxicity from native glucagon or MAR-D28 (up to 2.5 mg/ml) at a pH of 10 in a glycine solvent. We found a mild cytotoxicity for both compounds in Tris buffer at pH 8.5. A high concentration of the commercial glucagon preparation (GlucaGen) caused marked cytotoxicity, but low pH and/or a high osmolarity probably accounted primarily for this effect. With SEC, the decline in monomeric glucagon over time was much lower when aged in glycine (pH 10) than when aged in Tris (pH 8.5) or in citrate (pH 3). Congo red staining for amyloid was very low with the glycine preparation (pH 10). In the pig studies, the hyperglycemic effect of commercially available glucagon was preserved despite aging conditions associated with marked amyloid formation. Conclusions Under certain conditions, aqueous solutions of glucagon and MAR-D28 are stable for at least 5 days and are thus very likely to be safe in mammals. Glycine buffer at a pH of 10 appears to be optimal for avoiding cytotoxicity and amyloid fibril formation. PMID:21129325
NASA Astrophysics Data System (ADS)
Xu, S.; Walczak, J. J.; Wang, L.; Bardy, S. L.; Li, J.
2010-12-01
In this research, we investigate the effects of starvation on the transport of E. coli K12 in saturated porous media. Particularly, we examine the relationship between such effects and the pH and ionic strength of the electrolyte solutions that were used to suspend bacterial cells. E. coli K12 (ATCC 10798) cells were cultured using either Luria-Bertani Miller (LB-Miller) broth (10 g trypton, 5 g yeast extract and 10 g NaCl in 1 L of deionized water) or LB-Luria broth (10 g tryptone, 5 g yeast extract and 0.5 g NaCl in 1 L of deionized water). Both broths had similar pH (~7.1) but differed in ionic strength (LB-Miller: ~170 mM, LB-Luria: ~ 8 mM). The bacterial cells were then harvested and suspended using one of the following electrolyte solutions: phosphate buffered saline (PBS) (pH ~7.2; ionic strength ~170 mM), 168 mM NaCl (pH ~5.7), 5% of PBS (pH ~ 7.2; ionic strength ~ 8 mM) and 8 mM NaCl (pH ~ 5.7). Column transport experiments were performed at 0, 21 and 48 hours following cell harvesting to evaluate the change in cell mobility over time under “starvation” conditions. Our results showed that 1) starvation increased the mobility of E. coli K12 cells; 2) the most significant change in mobility occurred when bacterial cells were suspended in an electrolyte solution that had different pH and ionic strength (i.e., LB-Miller culture suspended in 8 mM NaCl and LB-Luria culture suspended in 168 mM Nacl); and 3) the change in cell mobility primarily occurred within the first 21 hours. The size of the bacterial cells was measured and the surface properties (e.g., zeta potential, hydrophobicity, cell-bound protein, LPS sugar content, outer membrane protein profiles) of the bacterial cells were characterized. We found that the measured cell surface properties could not fully explain the observed changes in cell mobility caused by starvation.
Experimental study of the bending elasticity of charged lipid bilayers in aqueous solutions with pH5
NASA Astrophysics Data System (ADS)
Mitkova, D.; Stoyanova-Ivanova, A.; Ermakov, Yu A.; Vitkova, V.
2012-12-01
Exposure to high concentrations of contaminations due to air polluting gases, vapours and aerosols and possibly altering the normal pH in the body could lead to undesirable changes in the properties of biological cells. Here, we study experimentally the mechanical properties of synthetic phospholipid bilayers containing increasing molar fractions (up to 0.15) of charged lipid (synthetic phosphatidylserine) in aqueous solutions with controlled ionic strength and at pH 5, which is slightly lower than the physiological values of pH. Our observations in phase contrast and fluorescence testified to the coexistence of two phases in membranes for temperatures below 29°C. Micro-sized inhomogeneities in vesicle membranes were systematically observed at temperatures lower than 29°C and for molar fractions of phosphatidylserine in the bilayer higher than 0.1. For the quantitative determination of the membrane bending rigidity, we applied thermal fluctuation analysis of the shape of quasispherical lipid vesicles. As far as the liquid-crystalline state of the bilayer is a necessary condition for the application of the experimental method, only vesicles satisfying this requirement were processed for determination of their membrane bending rigidity. The value obtained for the bending modulus of bilayers with 0.15 molar content of charged lipid is about two times higher than the bending modulus of uncharged membranes in the same bathing solution. These findings are in qualitative agreement with our previous results for the bending rigidity of charged bilayers, measured by vesicle micromanipulation.
Simoncic, Z; Roskar, R; Gartner, A; Kogej, K; Kmetec, V
2008-05-22
Perindopril Erbumine (PER) is one of the newly used angiotensin-converting enzyme inhibitors (ACE inhibitors) and is used for the treatment of patients with hypertension and symptomatic heart failure. It has two main degradation pathways, i.e. the degradation by hydrolysis and the degradation by cyclization. An isothermal heat conduction microcalorimetry (MC) and high pressure liquid chromatography (HPLC) were used for the characterization of aqueous solutions of PER and its stability properties. The rates of heat evolved during degradation of perindopril were measured by MC as a function of temperature and pH and from these data rate constant and change in enthalpy of the reactions were determined. With the HPLC method the concentration of perindopril and its degradation products were measured as a function of time in aqueous solutions of different pH that were stored at different temperatures. We demonstrated that reactions of degradation of perindopril at observed conditions follow the first order kinetics. The Arrhenius equation for each pH was determined. At pH 6.8 only one degradation pathway is present, i.e. the degradation by hydrolysis. Degradation constants for this pathway calculated from MC data are in good agreement with those obtained from HPLC. MC as a non-specific technique was shown to be useful in studies of PER when one reaction was present in the sample and also when more chemical and physical processes were simultaneously running.
Parikova, Alena; Struijk, Dirk G; Zweers, Machteld M; Langedijk, Monique; Schouten, Natalie; van den Berg, Nicole; Duis, Saskia; Krediet, Raymond T
2007-01-01
Peritoneal function tests are performed in peritoneal dialysis (PD) patients to characterize peritoneal membrane status. A low pH/high glucose degradation product (GDP) dialysis solution is used as the test solution. The objective of the present study was to compare a 3.86% glucose, low pH/high GDP dialysis solution (pH 5.5) with a 3.86% glucose, normal pH/low GDP dialysis solution (pH 7.4) in assessments of peritoneal membrane function. Two standard peritoneal permeability analyses (SPA) were performed in 10 stable PD patients within 2 weeks. One SPA was done with the 3.86% low pH/high GDP solution, and the other with the 3.86% normal pH/low GDP solution. The sequence of the two tests was randomized. Fluid transport parameters and glucose absorption were not different between the two groups. No differences were found for the mass transfer area coefficients (MTACs) of low molecular weight solutes calculated over the whole dwell. However, MTAC urea in the first hour of the dwell was higher in the test done with low pH/high GDP dialysate, suggesting more peritoneal vasodilation. No difference was found in protein clearances. Sodium sieving at multiple time points during the dwell was similar with the two solutions. The results obtained with the glucose-containing normal pH/low GDP dialysis solution were similar to those obtained with the glucose-containing low pH/high GDP dialysate in assessments of peritoneal membrane function.
HDP for the Neutralized pH Value Control in the Clarifying Process of Sugar Cane Juice
NASA Astrophysics Data System (ADS)
Lin, Xiaofeng; Yang, Jiaran
2009-05-01
Neutralizing pH value of sugar cane juice is the important craft in the control process in the clarifying process of sugar cane juice, which is the important factor to influence output and the quality of white sugar. On the one hand, it is an important content to control the neutralized pH value within a required range, which has the vital significance for acquiring high quality purified juice, reducing energy consumption and raising sucrose recovery. On the other hand, it is a complicated physical-chemistry process, which has the characteristics of strong non-linearity, time-varying, large time-delay, and multi-input. Therefore, there has not been a very good solution to control the neutralized pH value. Firstly, in this chapter, a neural network model for the clarifying process of sugar juice is established based on gathering 1200 groups of real-time sample data in a sugar factory. Then, the HDP (Heuristic Dynamic Programming) method is used to optimize and control the neutralized pH value in the clarifying process of sugar juice. Simulation results indicate that this method has good control effect. This will build a good foundation for stabilizing the clarifying process and enhancing the quality of the purified juice and lastly enhancing the quality of white sugar.
NASA Astrophysics Data System (ADS)
Wei, Wei; Wu, Xin-qiang; Ke, Wei; Xu, Song; Feng, Bing; Hu, Bo-tao
2017-09-01
Electrochemical corrosion behavior of a thermal-sprayed Ni-Al-coated Q235 steel was investigated in the simulated soil solutions at different pH values using measurements of potentiodynamic polarization curves and electrochemical impedance spectroscopy as well as surface analyses including x-ray diffraction analysis, scanning electron microscope equipped with an energy-dispersive x-ray spectroscopy and x-ray photoelectron spectroscopy. The results showed that the corrosion resistance of the Ni-Al-coated Q235 steel was dependent on the pH of the test solution. From pH = 3.53 to pH = 4.79, the corrosion resistance of the coated steel increased rapidly. In the pH range from 4.79 to 12.26, the corrosion resistance exhibited no significant change. At pH 13.25, the corrosion resistance of the sample was found to decrease. The calculated corrosion rate of Ni-Al-coated Q235 steel was lower than that of the uncoated Q235 steel and galvanized steel in all the test solutions. Over a wide range of pH values, the Ni-Al-coated Q235 steel exhibited extremely good corrosion resistance. The experimental data together with the potential-pH diagrams provided a basis for a detailed discussion of the related corrosion mechanisms of the coated steel.
Characterization of pH-fractionated humic acids derived from Chinese weathered coal.
Zhang, Shuiqin; Yuan, Liang; Li, Wei; Lin, Zhian; Li, Yanting; Hu, Shuwen; Zhao, Bingqiang
2017-01-01
To reduce the compositional and structural heterogeneity of humic acids (HAs) and achieve better use of HA resources, in this study, we report a new sequential dissolution method for HAs derived from Chinese weathered coal. This method was used to separate HAs into seven fractions by adjusting the pH (3-10) of the extraction solution. The results showed that the HA fractions derived from Chinese weathered coal were concentrated up to 90.31% in the lower pH solutions (3-7). The compositional and structural characteristics of the HA fractions were determined by elemental analysis; ultraviolet-visible (UV-Vis), Fourier transform infrared (FTIR), and solid-state 13 C-nuclear magnetic resonance (NMR) spectroscopies; and other techniques. The results showed significant differences among the HA fractions. The concentrations of the total acidic groups and the carboxyl groups decreased with the increasing pH of the extraction solution. However, the HA fractions derived from extraction solutions with pH 3-4 had relatively lower aromaticity but a higher protonated carbon content. The HA fractions derived from extraction solutions with pH 6-7 had the highest aromaticity and the greatest abundance of COO/N-C=O. This study demonstrated that adjusting the pH of the extraction solution is one way to fractionate HAs from Chinese weathered coal and to obtain HA fractions with compositions and structures that could serve as useful material for study and utilization. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liu, Ya-Fei; Oey, Indrawati; Bremer, Phil; Carne, Alan; Silcock, Pat
2017-01-01
The effect of either pulsed electric fields (PEF) or thermal processing on protein aggregation of ovomucin-depleted egg white (OdEW) solutions at different pH was assessed by solution turbidity and SDS-PAGE. Heating to 60°C for 10min caused marked protein aggregation of OdEW at pH5, 7, and 9. At constant electric field strength (E=1.4-1.8kV/cm), PEF processing under high specific energy input (W spec =260-700kJ/kg) induced some protein aggregation at pH5 and 7, but not at either pH4 or 9. Similar effects of pH on protein aggregation were observed upon PEF processing at varied E (from 0.7 to 1.7kV/cm) but with constant W spec (713kJ/kg). Analysis by SDS-PAGE revealed that proteins in the OdEW solution at pH5 were most susceptible to both PEF- and heat-induced protein aggregation and lysozyme was only involved in the formation of insoluble aggregates under PEF. The present study shows that PEF treatment has considerable potential for minimizing protein aggregation in the processing of heat-labile egg white proteins. Retaining the OdEW proteins in solution during processing has potential industry application, for example, protein fortification of drinks with OdEW, where minimizing solution turbidity would be advantageous. Copyright © 2016 Elsevier Ltd. All rights reserved.
Yang, Zongbo; Cheng, Jun; Xu, Xiaodan; Zhou, Junhu; Cen, Kefa
2016-07-01
Novel horizontal tubes and triangular prism (HTTP) baffles that generate flow vortices were developed to increase solution velocity between dark and light areas and thus improve microalgal growth in a flat-panel photo-bioreactor. Solution velocity, mass-transfer coefficient, and mixing time were measured with a particle-imaging velocimeter, dissolved oxygen probes, and pH probes. The solution mass-transfer coefficient increased by 30% and mixing time decreased by 21% when the HTTP baffles were used. The solution velocity between dark and light areas increased from ∼0.9cm/s to ∼3.5cm/s, resulting in a decreased dark-light cycle period to one-fourth. This enhanced flashing light effect with the HTTP baffles dramatically increased microalgae biomass yield by 70% in the flat-panel photo-bioreactor. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pokrovsky, Oleg S.; Schott, Jacques
2000-10-01
Surfaces of natural and synthetic forsterite (Fo 91 and Fo 100) in aqueous solutions at 25°C were investigated using surface titrations in batch and limited residence time reactors, column filtration experiments, electrokinetic measurements (streaming potential and electrophoresis techniques), Diffuse Reflectance Infrared Spectroscopy (DRIFT), and X-ray Photoelectron Spectroscopy (XPS). At pH < 9, a Mg-depleted, Si-rich layer (<20 Å thick) is formed on the forsterite surface due to a Mg 2+ ↔ H + exchange reaction. Electrokinetic measurements yield a pH IEP value of 4.5 corresponding to the dominance of SiO 2 in the surface layer at pH < 9. In contrast, surface titrations of fresh powders give an apparent pH PZC of about 10 with the development of a large positive charge (up to 10 -4 mol/m 2 or 10 C/m 2) in the acid pH region. This may be explained by penetration of H + into the first unit cells of forsterite surface. The surface charge of acid-reacted forsterite is one or two orders of magnitude lower than that of unreacted forsterite with an apparent pH PZC at around 6.5 and a pH IEP value of 2.1 which is close to that for amorphous silica and reflects the formation of a silica-rich layer on the surface. XPS analyses indicate the penetration of hydrogen into the surface and the polymerization of silica tetrahedra in this leached layer. At pH > 10, a Si-deficient, Mg-rich surface layer is formed as shown by XPS analyses and the preferential Si release from the surface during column filtration experiments.
NASA Astrophysics Data System (ADS)
Yaremko, Z. M.; Fedushinskaya, L. B.; Burka, O. A.; Soltys, M. N.
2014-09-01
The role of hydrophobic interaction in the development of associative processes is demonstrated, based on the concentration dependences of the viscosity and pH of binary solutions of polymethacrylic acid as an anionic polyelectrolyte and sodium laureth sulfate as an anionic surfactant. It is found that the inflection point on the dependence of the difference between the pH values of binary solutions of polymethacrylic acid and sodium laureth sulfate on the polyelectrolyte concentration is a criterion for determining the predominant contribution from hydrophobic interaction, as is the inflection point on the dependence of pH of individual solutions of polymethacrylic acid on the polyelectrolyte concentration.
NASA Astrophysics Data System (ADS)
Qiao, Congde; Zhang, Jianlong; Kong, Aiqun
2017-02-01
An investigation of the influences of pH, salt type, and salt concentration on the conformations of gelatin molecules in trivalent chromium salt solutions was performed by viscosity and dynamic light scattering (DLS) techniques. It was found that the viscosity behaviors as polyelectrolytes or polyampholytes depended on the charge distribution on the gelatin chains, which can be tuned by the value of pH of the gelatin solution. The intrinsic viscosity of gelatin in basic chromium sulfate aqueous solution at pH = 2.0 first decreased and then increased with increasing Cr(OH)SO4 concentration, while a monotonic decrease of the intrinsic viscosity of gelatin was observed in CrCl3 solution. However, the intrinsic viscosity of gelatin at pH = 5.0 was found to be increased first and then decreased with an increase in salt concentration in Cr(OH)SO4 solution, as well as in CrCl3 solution. We suggested that the observed viscosity behavior of gelatin in trivalent chromium salt solutions was attributed to the comprehensive effects of shielding, overcharging, and crosslinking (complexation) caused by the introduction of the different counterions. In addition, the average hydrodynamic radius ( R h ) of gelatin molecules in various salt solutions was determined by DLS. It was found that the change trend of R h with salt concentration was the same as the change of intrinsic viscosity. Based on the results of the viscosity and DLS, a possible mechanism for the conformational transition of gelatin chains with external conditions including pH, salt concentration, and salt type is proposed.
Ratiometric Imaging of Extracellular pH in Dental Biofilms.
Schlafer, Sebastian; Dige, Irene
2016-03-09
The pH in bacterial biofilms on teeth is of central importance for dental caries, a disease with a high worldwide prevalence. Nutrients and metabolites are not distributed evenly in dental biofilms. A complex interplay of sorption to and reaction with organic matter in the biofilm reduces the diffusion paths of solutes and creates steep gradients of reactive molecules, including organic acids, across the biofilm. Quantitative fluorescent microscopic methods, such as fluorescence life time imaging or pH ratiometry, can be employed to visualize pH in different microenvironments of dental biofilms. pH ratiometry exploits a pH-dependent shift in the fluorescent emission of pH-sensitive dyes. Calculation of the emission ratio at two different wavelengths allows determining local pH in microscopic images, irrespective of the concentration of the dye. Contrary to microelectrodes the technique allows monitoring both vertical and horizontal pH gradients in real-time without mechanically disturbing the biofilm. However, care must be taken to differentiate accurately between extra- and intracellular compartments of the biofilm. Here, the ratiometric dye, seminaphthorhodafluor-4F 5-(and-6) carboxylic acid (C-SNARF-4) is employed to monitor extracellular pH in in vivo grown dental biofilms of unknown species composition. Upon exposure to glucose the dye is up-concentrated inside all bacterial cells in the biofilms; it is thus used both as a universal bacterial stain and as a marker of extracellular pH. After confocal microscopic image acquisition, the bacterial biomass is removed from all pictures using digital image analysis software, which permits to exclusively calculate extracellular pH. pH ratiometry with the ratiometric dye is well-suited to study extracellular pH in thin biofilms of up to 75 µm thickness, but is limited to the pH range between 4.5 and 7.0.
Souza, Erick Miranda; Calixto, Amanda Martins; Lima, Camila Nara E; Pappen, Fernanda Geraldo; De-Deus, Gustavo
2014-10-01
Stabilizing sodium hypochlorite (NaOCl) at an alkaline pH is proposed to increase solution stability and tissue dissolution ability; however, a reduction on the flexural strength of dentin discs has been found to be a side effect. This study sought to determine whether a stabilized alkaline NaOCl reduces the fracture resistance of root canal-treated bovine teeth after root canal preparation compared with a neutral solution counterpart. The 4 anterior incisors were removed from 20 mandibular bovine jaws, and each 1 was randomly assigned to 1 of 4 groups (20 teeth each). Teeth were prepared with a sequence of 6 K-type files. The following experimental groups received a different irrigation regimen: G1: distilled water (negative control), G2: 5% NaOCl at a pH of 7.2, and G3: 5% NaOCl at a pH of 12.8; in the positive control group (G4), teeth remained untreated. The time of contact and volume of solution were carefully standardized. After bone and periodontal ligament simulation, teeth were subjected to a fracture resistance test. A significant difference was observed among the 4 groups tested (analysis of variance, P < .05). The 5% NaOCl groups (G2 and G3) presented significantly lower resistance to fracture than the control (G1 and G4) (Tukey test, P < .05). Both NaOCl solutions similarly reduced the fracture resistance at approximately 30% (Tukey test, P > .05). No differences were observed between positive and negative control groups (Tukey test, P > .05). Stabilized alkaline and neutral NaOCl solutions similarly reduced the fracture resistance of root canal-treated bovine teeth by about 30%. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
[Adsorbent effect of activated carbon on small molecular uremic toxin and its influence factors].
Yang, Bo; Jiang, Yun-sheng; Li, Jun
2003-06-01
To analyze the adsorbent effect of activated carbon on uremic toxin and its influence factors. Uremic toxins (urea, creatinine and uric acid) were dissolved in the distilled water to obtain uremic toxic solution. Activated carbon was added to the solution, and the concentrations of uremic toxins were measured at different time spots. To determine the influence factors, some possible related materials, such as bile, amino acid, Ringer's, solution of glucose, HCl or NaOH respectively were added simultaneously. The concentrations of toxins in uremic toxic solution decreased 5 min after adding the activated carbon. The concentration of urea was the lowest at 30 min, but it increased after 50 min; while the concentrations of creatinine and uric acid reached the lowest level from 10 to 30 min after adding the activated carbon, and maintained at the same level after that. The bile, amino acid, electrolyte, glucose and pH value did not influence the adsorption of uric acid significantly, but they influenced the adsorption of urea and creatinine. Bile and amino acid influenced the concentration of urea remarkably, following glucose, NaOH and HCl. The effect of pH 2.0 solution on the creatinine concentration was the most significant, following glucose. Activated carbon has adsorptive effect on uremic toxins, but its adsorptive effect decreases as time goes on. Bile, glucose, amino acid, NaOH and HCl can affect the adsorptive effect of activated carbon on uremic toxins to some extent.
Fluoride release from fluoride varnishes under acidic conditions.
Lippert, F
2014-01-01
The aim was to investigate the in vitro fluoride release from fluoride varnishes under acidic conditions. Poly(methyl methacrylate) blocks (Perspex, n=3 per group) were painted with 80 ± 5 mg fluoride varnish (n=10) and placed into artificial saliva for 30 min. Then, blocks were placed into either 1% citric acid (pH 2.27) or 0.3% citric acid (pH 3.75) solutions (n=3 per solution and varnish) for 30 min with the solutions being replaced every 5 min. Saliva and acid solutions were analyzed for fluoride content. Data were analyzed using three-way ANOVA (varnish, solution, time). The three-way interaction was significant (p>0.0001). Fluoride release and release patterns varied considerably between varnishes. Fluoride release in saliva varied by a factor of more than 10 between varnishes. Some varnishes (CavityShield, Nupro, ProFluorid, Vanish) showed higher fluoride release in saliva than during the first 5 min of acid exposure, whereas other varnishes (Acclean, Enamel-Pro, MI Varnish, Vella) showed the opposite behavior. There was little difference between acidic solutions. Fluoride release from fluoride varnishes varies considerably and also depends on the dissolution medium. Bearing in mind the limitations of laboratory research, the consumption of acidic drinks after fluoride varnish application should be avoided to optimize the benefit/risk ratio.
NASA Astrophysics Data System (ADS)
Haldenwang, P.; Guérin, R.; Le Marec, C.
1999-06-01
2-D unsteady flow patterns in upward Bridgman solidification are numerically investigated. The alloy under study is Pb-30%Tl. The purpose of the contribution is to characterise the striations induced by unsteadiness in the growing crystal. Unsteady solution branches are studied from onset threshold of unsteadiness to chaos. We report two examples for which time behaviour of a given solution branch is studied versus Rayleigh number. We then estimate the magnitude of the time fluctuations in solute composition that the crystal incorporates. The period of the striations is also discussed. Nous étudions numériquement les structures hydrodynamiques de la convection solutale dans le bain fondu, lors de la solidification dirigée d'alliages binaires. Plus précisément, cette étude porte
Chromatography of blood-clotting factors and serum proteins on columns of diatomaceous earth.
MILSTONE, J H
1955-07-20
1. In batch adsorptions with prothrombin solutions, hyflo was the weakest adsorbent, standard super-cel intermediate, and filter-cel strongest. Of these three grades of diatomaceous earth, hyflo has the smallest surface area per gram and filter-cel the largest. In parallel breakthrough experiments, a column of standard super-cel had a capacity almost six times that of a hyflo column. 2. After partial removal of impurities by diatomaceous earth, prothrombin preparations contained less thrombokinase, were more stable, and displayed less tendency to form thrombin "spontaneously." Thrombokinase (or its precursor) was removed from a preparation of prothrombin by passage through a filter cake of standard super-cel. The specific activity of the prothrombin was increased; and 62 per cent of the activity was recovered. 3. Prothrombin was adsorbed from an ammonium sulfate solution at pH 5.26 by columns of hyflo or standard super-cel. When eluted by phosphate solutions, the protein moved down the columns more readily at higher pH and higher concentration of phosphate salts, within the pH range 5.0 to 6.6, and within the phosphate range 0.1 to 1.0 M. 4. Thrombin was adsorbed on a column of standard super-cel at pH 5.11. As successive eluents passed through the column, the thrombin emerged between two bands of impurities. The specific activity of the thrombin was raised; and 83 per cent of the activity was recovered. 5. With a column of standard super-cel, and with a series of eluents within the pH range 5.1 to 6.3, total serum proteins were separated into four major bands. About 94 per cent of the protein was recovered.
CHROMATOGRAPHY OF BLOOD-CLOTTING FACTORS AND SERUM PROTEINS ON COLUMNS OF DIATOMACEOUS EARTH
Milstone, J. H.
1955-01-01
1. In batch adsorptions with prothrombin solutions, hyflo was the weakest adsorbent, standard super-cel intermediate, and filter-cel strongest. Of these three grades of diatomaceous earth, hyflo has the smallest surface area per gram and filter-cel the largest. In parallel breakthrough experiments, a column of standard super-cel had a capacity almost six times that of a hyflo column. 2. After partial removal of impurities by diatomaceous earth, prothrombin preparations contained less thrombokinase, were more stable, and displayed less tendency to form thrombin "spontaneously." Thrombokinase (or its precursor) was removed from a preparation of prothrombin by passage through a filter cake of standard super-cel. The specific activity of the prothrombin was increased; and 62 per cent of the activity was recovered. 3. Prothrombin was adsorbed from an ammonium sulfate solution at pH 5.26 by columns of hyflo or standard super-cel. When eluted by phosphate solutions, the protein moved down the columns more readily at higher pH and higher concentration of phosphate salts, within the pH range 5.0 to 6.6, and within the phosphate range 0.1 to 1.0 M. 4. Thrombin was adsorbed on a column of standard super-cel at pH 5.11. As successive eluents passed through the column, the thrombin emerged between two bands of impurities. The specific activity of the thrombin was raised; and 83 per cent of the activity was recovered. 5. With a column of standard super-cel, and with a series of eluents within the pH range 5.1 to 6.3, total serum proteins were separated into four major bands. About 94 per cent of the protein was recovered. PMID:13242761
Khodadoust, Saeid; Kouri, Narges Cham; Talebiyanpoor, Mohammad Sharif; Deris, Jamile; Pebdani, Arezou Amiri
2015-12-01
In this work a simple, inexpensive, and sensitive optical sensor based on triacetylcellulose membrane as solid support was developed by using immobilization of Giemsa indicator for pH measurement. In this method, the influence variables on the membrane performance including pH concentration of indicator, response time, ionic strength, and reversibility were investigated. At optimum values of all variables the response of optical pH sensor is linear in the pH range of 3.0-12.0. This optical sensor was produced through simultaneous binding of the Giemsa on the activated triacetylcellulose membrane which responded to the pH changes in a broader linear range within less than 2.0 min and suitable reproducibility (RSD<5%). Stability results showed that this sensor was stable after 6 months of storage in the water/ethanol (50:50, v/v) solution without any measurable divergence in response properties (less than 5% RSD). Copyright © 2015 Elsevier B.V. All rights reserved.
Development and characterization of a voltammetric carbon-fiber microelectrode pH sensor.
Makos, Monique A; Omiatek, Donna M; Ewing, Andrew G; Heien, Michael L
2010-06-15
This work describes the development and characterization of a modified carbon-fiber microelectrode sensor capable of measuring real-time physiological pH changes in biological microenvironments. The reagentless sensor was fabricated under ambient conditions from voltammetric reduction of the diazonium salt Fast Blue RR onto a carbon-fiber surface in aprotic media. Fast-scan cyclic voltammetry was used to probe redox activity of the p-quinone moiety of the surface-bound molecule as a function of pH. In vitro calibration of the sensor in solutions ranging from pH 6.5 to 8.0 resulted in a pH-dependent anodic peak potential response. Flow-injection analysis was used to characterize the modified microelectrode, revealing sensitivity to acidic and basic changes discernible to 0.005 pH units. Furthermore, the modified electrode was used to measure dynamic in vivo pH changes evoked during neurotransmitter release in the central nervous system of the microanalytical model organism Drosophila melanogaster.
Development and Characterization of a Voltammetric Carbon-fiber Microelectrode pH Sensor
Makos, Monique A.; Omiatek, Donna M.; Ewing, Andrew G.; Heien, Michael L.
2010-01-01
This work describes the development and characterization of a modified carbon-fiber microelectrode sensor capable of measuring real-time physiological pH changes in biological microenvironments. The reagentless sensor was fabricated under ambient conditions from voltammetric reduction of the diazonium salt Fast Blue RR onto a carbon-fiber surface in aprotic media. Fast-scan cyclic voltammetry was used to probe redox activity of the p-quinone moiety of the surface-bound molecule as a function of pH. In vitro calibration of the sensor in solutions ranging from pH 6.5 to 8.0 resulted in a pH-dependent anodic peak potential response. Flow-injection analysis was used to characterize the modified microelectrode, revealing sensitivity to acidic and basic changes discernable to 0.005 pH units. Furthermore, the modified electrode was used to measure dynamic in vivo pH changes evoked during neurotransmitter release in the central nervous system of the microanalytical model organism Drosophila melanogaster. PMID:20380393
The Effects of ph on Structural and Optical Characterization of Iron Oxide Thin Films
NASA Astrophysics Data System (ADS)
Tezel, Fatma Meydaneri; Özdemir, Osman; Kariper, I. Afşin
In this study, the iron oxide thin films have been produced by chemical bath deposition (CBD) method as a function of pH onto amorphous glass substrates. The surface images of the films were investigated with scanning electron microscope (SEM). The crystal structures, orientation of crystallization, crystallite sizes, and dislocation density i.e. structural properties of the thin films were analyzed with X-ray diffraction (XRD). The optical band gap (Eg), optical transmission (T%), reflectivity (R%), absorption coefficient (α), refraction index (n), extinction coefficient (k) and dielectric constant (ɛ) of the thin films were investigated depending on pH, deposition time, solution temperature, substrate temperature, thickness of the films by UV-VIS spectrometer.
Heavy metals alter the electrokinetic properties of bacteria, yeasts, and clay minerals.
Collins, Y E; Stotzky, G
1992-01-01
The electrokinetic patterns of four bacterial species (Bacillus subtilis, Bacillus megaterium, Pseudomonas aeruginosa, and Agrobacterium radiobacter), two yeasts (Saccharomyces cerevisiae and Candida albicans), and two clay minerals (montmorillonite and kaolinite) in the presence of the chloride salts of the heavy metals, Cd, Cr, Cu, Hg, Ni, Pb, and Zn, and of Na and Mg were determined by microelectrophoresis. The cells and kaolinite were net negatively charged at pH values above their isoelectric points (pI) in the presence of Na, Mg, Hg, and Pb at an ionic strength (mu) of 3 x 10(-4); montmorillonite has no pI and was net negatively charged at all pH values in the presence of these metals. However, the charge of some bacteria, S. cerevisiae, and kaolinite changed to a net positive charge (charge reversal) in the presence of Cd, Cr, Cu, Ni, and Zn at pH values above 5.0 (the pH at which charge reversal occurred differed with the metal) and then, at higher pH values, again became negative. The charge of the bacteria and S. cerevisiae also reversed in solutions of Cu and Ni with a mu of greater than 3 x 10(-4), whereas there was no reversal in solutions with a mu of less than 3 x 10(-4). The clays became net positively charged when the mu of Cu was greater than 3 x 10(-4) and that of Ni was greater than 1.5 x 10(-4). The charge of the cells and clays also reversed in solutions containing both Mg and Ni or both Cu and Ni (except montmorillonite) but not in solutions containing both Mg and Cu (except kaolinite) (mu = 3 x 10(-4)). The pIs of the cells in the presence of the heavy metals were at either higher or lower pH values than in the presence of Na and Mg. Exposure of the cells to the various metals at pH values from 2 to 9 for the short times (ca. 10 min) required to measure the electrophoretic mobility did not affect their viability. The specific adsorption on the cells and clays of the hydrolyzed species of some of the heavy metals that formed at higher pH values was probably responsible for the charge reversal. These results suggest that the toxicity of some heavy metals to microorganisms varies with pH because the hydrolyzed speciation forms of these metals, which occur at higher pH values, bind on the cell surface and alter the net charge of the cell.(ABSTRACT TRUNCATED AT 400 WORDS) PMID:1622229
USDA-ARS?s Scientific Manuscript database
Selenite Se(IV) and selenate Se(VI) adsorption behavior was investigated on gibbsite as a function of solution pH and solution ionic strength. Adsorption of both Se redox states decreased with increasing solution pH. Electrophoretic mobility measurements showed downward shifts in point of zero cha...
Influence of Soil Solution Salinity on Molybdenum Adsorption by Soils
USDA-ARS?s Scientific Manuscript database
Molybdenum (Mo) adsorption on five arid-zone soils from California was investigated as a function of equilibrium solution Mo concentration (0-30 mg L-1), solution pH (4-8), and electrical conductivity (EC = 0.3 or 8 dS m-1). Molybdenum adsorption decreased with increasing pH. An adsorption maximum...
NASA Astrophysics Data System (ADS)
Mosayebi, Pegah; Dorranian, Davoud; Behzad, Kasra
A facile chemical reduction method was used to synthesize ZnO nanoparticles (NPs) in ethylene glycol solvent at two different calcination temperatures. As a result of variation in the calcination temperature, ZnO NPs with two different sizes were achieved. The NPs were investigated for their structural and optical characteristics using X-ray diffraction and ultraviolet (UV)-Vis spectroscopy. The synthesized ZnO NPs exhibited a hexagonal structure with sizes of 46 and 65nm. The synthesized NPs were then used to investigate dye photocatalytic behavior of products as a tunable UV detector for different skin types. The dye degradation and decolorization of methylene blue in the presence of ZnO NP, following UV radiation as a function of time, were studied at different pH levels. The optical absorption spectra were then taken every 15min for all samples. The UV-Vis spectroscopy spectra revealed that optical absorption of solution was decreased upon UV exposure as a function of time. Photocatalytic reaction indicated that the dye degradation and decolorization rate were accelerated with the increase of pH level. Therefore, a tunable UV detector for different skin types could be engineered by varying the pH level of solution to avoid human skin burning.
Xu, Xiaoming; Gupta, Abhay; Sayeed, Vilayat A; Khan, Mansoor A
2013-05-01
Various adverse events including esophagus irritations have been reported with the use of alendronate tablets, likely attributed to the rapid tablet disintegration in the mouth or esophagus. Accordingly, the disintegration of six alendronate tablet drug products was studied using a newly developed testing device equipped with in-line sensors, in addition to the official compendial procedure for measuring the disintegration time. The in-line sensors were used to monitor the particle count and solution pH change to assess the onset and duration of disintegration. A relatively large variation was observed in the disintegration time of the tested drug products using the compendial method. The data collected using the in-line sensors suggested that all tested drug products exhibited almost instantaneous onset of disintegration, under 2 s, and a sharp drop in solution pH. The drop in pH was slower for tablets with slower disintegration. The in-house prepared alendronate test tablets also showed similar trends suggesting rapid solubilization of the drug contributed to the fast tablet disintegration. This research highlights the usefulness of the newly developed in-line analytical method in combination with the compendial method in providing a better understanding of the disintegration and the accompanying drug solubilization processes for fast disintegrating tablet drug products. Copyright © 2013 Wiley Periodicals, Inc.
In Jae, Jeong; Dong Ju, Hyun; Dong Hyun, Kim; Yoon, Moon Soo; Lee, Hee Jung
2017-11-21
Superficial chemical peels are frequently used in acne vulgaris treatment. Although glycolic acid (GA) has been widely used in clinical practice, its pH ranges from 0.08-2.75 and thus should be neutralized after application to avoid burns. To evaluate treatment efficacy and safety of chemical peeling using buffered 50% GA (pH 3.0) + 0.5% salicylic acid (SA) solution that does not need to be neutralized in the treatment of acne vulgaris compared to the conventional peeling using Jessner's solution. We performed a prospective, randomized, evaluator-blind, split-face clinical trial. Twenty patients were randomized by assigning one side of each patient's face to receive a 50% GA (pH 3.0) + 0.5% SA peel (GA side) and the other side to receive the Jessner's solution (Jessner's solution side). All patients underwent 2 sessions of treatment spaced 2 weeks apart. Lesion count, acne severity, subjective efficacy assessment, and side effects were evaluated. The total lesion count was significantly reduced for the GA and Jessner's solution sides (P < .001). However, there was no significant difference in the total lesion count, acne severity, or subjective efficacy assessment between the 2 sides (P > .05). The GA side had fewer side effects than the Jessner's solution side. The results of this study suggest that chemical peeling using the 50% GA (pH 3.0) + 0.5% SA solution can be as effective and convenient as the conventional peeling using Jessner's solution in the treatment of acne vulgaris and may show fewer adverse events than the conventional peeling. © 2017 Wiley Periodicals, Inc.
The Effect of Temperature and Solution pH on the Nucleation of Tetragonal Lysozyme Crystals
NASA Technical Reports Server (NTRS)
Judge, Russell A.; Jacobs, Randolph S.; Frazier, Tyralynn; Snell, Edward H.; Pusey, Marc L.
1999-01-01
Part of the challenge of macromolecular crystal growth for structure determination is obtaining crystals with a volume suitable for x-ray analysis. In this respect an understanding of the effect of solution conditions on macromolecule nucleation rates is advantageous. This study investigated the effects of supersaturation, temperature, and pH on the nucleation rate of tetragonal lysozyme crystals. Batch crystallization plates were prepared at given solution concentrations and incubated at set temperatures over 1 week. The number of crystals per well with their size and axial ratios were recorded and correlated with solution conditions. Crystal numbers were found to increase with increasing supersaturation and temperature. The most significant variable, however, was pH; crystal numbers changed by two orders of magnitude over the pH range 4.0-5.2. Crystal size also varied with solution conditions, with the largest crystals obtained at pH 5.2. Having optimized the crystallization conditions, we prepared a batch of crystals under the same initial conditions, and 50 of these crystals were analyzed by x-ray diffraction techniques. The results indicate that even under the same crystallization conditions, a marked variation in crystal properties exists.
Li, Feng; Shen, Kaixuan; Long, Xiaolin; Wen, Jiasheng; Xie, Xiaojie; Zeng, Xiangyun; Liang, Yanyan; Wei, Yansha; Lin, Zefeng; Huang, Wenrou; Zhong, Ruida
2016-01-01
The study investigated the preparation and characterization of biochars from water hyacinth at 300°C to 700°C for cadmium (Cd) removal from aqueous solutions. The adsorption process was dominated by oxygen-containing functional groups with irregular surfaces via esterification reactions. Furthermore, the mineral components in the biochars also contributed to Cd absorption through precipitation. Parameters such as the effects of solution pH, contact time, and initial concentration were studied. The optimum pH value was observed at 5.0, in which nearly 90% of Cd was removed. The maximum Cd adsorption capacities based on the Langmuir isotherm were calculated at 49.837, 36.899, and 25.826 mg g(-1). The adsorption processes of the biochars followed the pseudo-second-order kinetics, with the equilibrium achieved around 5 h. The biochar from E. crassipes is a promising adsorbent for the treatment of wastewater, which can in turn convert one environmental problem to a new cleaning Technology.
Li, Feng; Shen, Kaixuan; Long, Xiaolin; Wen, Jiasheng; Xie, Xiaojie; Zeng, Xiangyun; Liang, Yanyan; Wei, Yansha; Lin, Zefeng; Huang, Wenrou; Zhong, Ruida
2016-01-01
The study investigated the preparation and characterization of biochars from water hyacinth at 300°C to 700°C for cadmium (Cd) removal from aqueous solutions. The adsorption process was dominated by oxygen-containing functional groups with irregular surfaces via esterification reactions. Furthermore, the mineral components in the biochars also contributed to Cd absorption through precipitation. Parameters such as the effects of solution pH, contact time, and initial concentration were studied. The optimum pH value was observed at 5.0, in which nearly 90% of Cd was removed. The maximum Cd adsorption capacities based on the Langmuir isotherm were calculated at 49.837, 36.899, and 25.826 mg g−1. The adsorption processes of the biochars followed the pseudo-second-order kinetics, with the equilibrium achieved around 5 h. The biochar from E. crassipes is a promising adsorbent for the treatment of wastewater, which can in turn convert one environmental problem to a new cleaning Technology. PMID:26882239
Panda, Gopal C; Das, Sujoy K; Guha, Arun K
2009-05-15
Jute stick powder (JSP) has been found to be a promising material for adsorptive removal of congo red (C.I. 22120) and rhodamine B (C.I. 45170) from aqueous solutions. Physico-chemical parameters like dye concentration, solution pH, temperature and contact time have been varied to study the adsorption phenomenon. Favorable adsorption occurs at around pH 7.0 whereas temperature has no significant effect on adsorption of both the dyes. The maximum adsorption capacity has been calculated to be 35.7 and 87.7mg/g of the biomass for congo red and rhodamine B, respectively. The adsorption process is in conformity with Freundlich and Langmuir isotherms for rhodamine B whereas congo red adsorption fits well to Langmuir isotherm only. In both the cases, adsorption occurs very fast initially and attains equilibrium within 60min. Kinetic results suggest the intra-particle diffusion of dyes as rate limiting step.
Huang, Ruihua; Zhang, Lujie; Hu, Pan; Wang, Jing
2016-05-01
Batch experiments were executed to investigate the removal of Congo red (CR) from aqueous solutions using the crosslinked chitosan (CCS) and crosslinked chitosan immobilized bentonite (CCS/BT composite). The CCS and CCS/BT composite were characterized by X-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR) techniques. The removal of CR was examined as a function of pH value of CR solution, contact time, and inorganic sodium salt and ionic strength. The equilibrium data of CCS and CCS/BT composite agreed well with the Langmuir model. The adsorption capacities of CCS and CCS/BT composite at 298K and natural pH value were 405 and 500 mg/g, respectively. The kinetic data correlated well with the pseudo-second-order model. The adsorption of CR onto the CCS was mainly controlled by chemisorption while the adsorption of CR onto the CCS/BT composite was controlled by chemisorption and the electrostatic attraction. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of soy sauce on physicochemical and textural properties of tumbled chicken breast.
Kim, H W; Hwang, K E; Song, D H; Kim, Y J; Lim, Y B; Choi, J H; Choi, Y S; Kim, H Y; Kim, C J
2014-03-01
The objective of this study was to evaluate the effects of soy sauce on the physicochemical and textural properties of tumbled chicken breasts. Chicken breasts marinated with distilled water (Con), 4% NaCl solution, 4% NaCl and lactic acid solution (pH 4.9), and soy sauce solution (4% salt concentration and pH 4.9) were vacuum tumbled at 3°C for 60 min. The chicken breast marinated with soy sauce solution showed lower lightness and higher redness and yellowness due to the color of the soy sauce. The acidic marinades led to a decrease in pH value of tumbled chicken breast. The acidic marinades increased collagen solubility of sample compared with 4% NaCl solution, resulting in decreased shear force. Water-holding capacity, marination and cooking yields, and solubility of myofibrillar proteins were mainly affected by the presence of salt in the marinade, rather than by pH alternation. Our results suggested that soy sauce marination can improve the tenderness of tumbled chicken breast.
Trimerization Dictates Solution Opalescence of a Monoclonal Antibody.
Yang, Teng-Chieh; Langford, Alex Jacob; Kumar, Sandeep; Ruesch, John Carl; Wang, Wei
2016-08-01
Opalescence, sometimes observed in antibody solutions, is thought to be mediated by light scattering of soluble oligomers or insoluble particulates. However, mechanistic features, such as stoichiometry and self-association affinity of oligomeric species related to opalescence, are poorly understood. Here, opalescence behavior of a monoclonal antibody (mAb-1) solution was studied over a wide range of solution conditions including different protein concentrations, pH, and in the presence or absence of salt. Hydrodynamic and thermodynamic properties of mAb-1 solutions were studied by analytical ultracentrifugation and dynamic light scattering. Opalescence in mAb-1 solutions is pH and concentration dependent. The degree of opalescence correlates with reversible monomer-trimer equilibrium detected by analytical ultracentrifugation. Increased trimer formation corresponds to increased opalescence in mAb-1 solutions at higher pH and protein concentrations. Addition of NaCl shifts this equilibrium toward monomer and reduces solution opalescence. This study demonstrates that opalescence in mAb-1 solutions does not arise from the light scattering of monomer or random molecular self-associations but is strongly correlated with a specific self-association stoichiometry and affinity. Importantly, at pH 5.5 (far below isoelectric point of mAb-1), the solution is not opalescent and with nonideal behavior. This study also dissects several parameters to describe the hydrodynamic and thermodynamic nonideality. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaacs, H.S.; Lamaka, S.V.; Taryba, M.
2011-01-01
This work reports a new methodology to measure quasi-simultaneously the local electric fields and the distribution of specific ions in a solution via selective microelectrodes. The field produced by the net electric current was detected using the scanning vibrating electrode technique (SVET) with quasi-simultaneous measurements of pH with an ion-selective microelectrode (pH-SME). The measurements were performed in a validation cell providing a 48 ?m diameter Pt wire cross section as a source of electric current. A time lag between acquiring each current density and pH data-point was 1.5 s due to the response time of pH-SME. The quasi-simultaneous SVET-pH measurementsmore » that correlate electrochemical oxidation-reduction processes with acid-base chemical equilibria are reported for the first time. No cross-talk between the vibrating microelectrode and the ion-selective microelectrode could be detected under given experimental conditions.« less
Study on kinetics of adsorption of humic acid modified by ferric chloride on U(VI)
NASA Astrophysics Data System (ADS)
Zhang, Y. Y.; Lv, J. W.; Song, Y.; Dong, X. J.; Fang, Q.
2017-11-01
In order to reveal the adsorption mechanism of the ferric chloride modified humic acid on uranium, the influence of pH value and contact time of adsorption on uranium was studied through a series of batch experiments. Meanwhile, the adsorption kinetics was analyzed with pseudo-first order kinetic model and pseudo-second order kinetic model. The results show that adsorption is affected by the pH value of the solution and by contract time, and the best condition for adsorption on uranium is at pH=5 and the adsorption equilibrium time is about 80 min. Kinetics of HA-Fe adsorption on uranium accords with pseudo-second order kinetic model. The adsorption is mainly chemical adsorption, and complexes were produced by the reaction between uranium ions and the functional groups on the surface of HA-Fe, which can provide reference for further study of humic acid effecting on the migration of U(VI) in soil.
Antibacterial Activity of pH-Dependent Biosynthesized Silver Nanoparticles against Clinical Pathogen
Chitra, Kethirabalan; Annadurai, Gurusamy
2014-01-01
Simple, nontoxic, environmental friendly method is employed for the production of silver nanoparticles. In this study the synthesized nanoparticles UV absorption band occurred at 400 nm because of the surface Plasmon resonance of silver nanoparticles. The pH of the medium plays important role in the synthesis of control shaped and sized nanoparticles. The colour intensity of the aqueous solution varied with pH. In this study, at pH 9, the colour of the aqueous solution was dark brown, whereas in pH 5 the colour was yellowish brown; the colour difference in the aqueous solution occurred due to the higher production of silver nanoparticles. The antibacterial activity of biosynthesized silver nanoparticles was carried out against E. coli. The silver nanoparticles synthesized at pH 9 showed maximum antibacterial activity at 50 μL. PMID:24967396
Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution.
Lin, Shu-Chiao; Huang, Chih-Fen; Shen, Li-Jiuan; Wang, Hsueh-Ju; Lin, Chia-Yu; Wu, Fe-Lin Lin
2015-12-01
Acanthamoeba keratitis is difficult to treat because Acanthamoeba cysts are resistant to the majority of antimicrobial agents. Despite the efficacy of 0.02% chlorhexidine in treating Acanthamoeba keratitis, a lack of data in the literature regarding the formulation's stability limits its clinical use. The objective of this study was to develop an optimal extemporaneous 0.02% chlorhexidine digluconate ophthalmic formulation for patients in need. With available active pharmaceutical ingredients, 0.02% chlorhexidine digluconate sample solutions were prepared by diluting with BSS Plus Solution or acetate buffer. Influences of the buffer, type of container, and temperature under daily-open condition were assessed based on the changes of pH values and chlorhexidine concentrations of the test samples weekly. To determine the beyond-use date, the optimal samples were stored at 2-8°C or room temperature, and analyzed at time 0 and at Week 1, Week 2, Week 3, Week 4, Week 5, Week 8, Week 12, and Week 24. Despite chlorhexidine exhibiting better stability in acetate buffer than in BSS solution, its shelf-life was < 14 days when stored in a light-resistant low-density polyethylene container. The acetate-buffered 0.02% chlorhexidine digluconate solution stored in light-resistant high-density polyethylene eyedroppers did not exhibit significant changes in pH or strength at any time interval. The acetate-buffered 0.02% chlorhexidine digluconate ophthalmic solution stored in light-resistant high-density polyethylene eyedroppers demonstrated excellent stability at 2-25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription. Copyright © 2014. Published by Elsevier B.V.
Wu, H; Zhang, Z X; Zhao, H P; Wu, D C; Wu, B L; Cong, R
2004-12-01
Sodium fluoride-loaded gelatin microspheres (NaF-GMS) were prepared using double-phase emulsified condensation polymerization. The average diameter of microspheres was (11.33+/-5.56) microm. The drug content and encapsulation efficiency were 8.80% and 76.73%, respectively. The fluoride releasing profiles of NaF-GMS in physiological saline and artificial saliva (pH 4.5, pH 6.8) showed that NaF-GMS had a sustained-release property and fluoride release rate was increased in pH 4.5 artificial saliva. Experiments conducted in rabbits' oral cavity using NaF-GMS and NaF solution as control revealed NaF-GMS could maintain oral fluoride retention longer than NaF solution. Cariostatic abilities of NaF-GMS including demineralization prohibition in vitro, fluoride deposition in artificial dental plaque and the ability of targeting to cariogenic bacteria were investigated in artificial dental plaque. The results indicated NaF-GMS with lower fluoride concentrations could achieve equivalent cariostatic effect to the concentrated NaF solution, at the same time, could prolong fluoride retention in dental plaque. Microscopic observation showed that NaF-GMS carrying fusion protein of glucan-binding domain could adhere more bacteria than NaF-GMS and this might indicate the possibility of targeting to cariogenic bacteria when NaF-GMS were properly modified.
Prado-Gotor, R; López-Pérez, G; Martín, M J; Cabrera-Escribano, F; Franconetti, A
2014-06-01
A systematic study of the interaction between free anionic gold nanoparticles and chitosan in a solution is presented. A spectroscopic study of the interaction between 10nm gold nanoparticles and low molecular weight chitosan is reported as a function of the concentration and pH of the polymer in a solution. Zeta potential measurements and TEM images indicate the effective aggregation of the nanoparticles in the presence of chitosan. At the same time, anionic gold nanoparticles act as crosslink agents to form chitosan nanocapsules with an average molecular size of 260nm. The changes of the surface plasmon band due to the adsorption of the polymer on the nanoparticle surface allow using of the citrate gold nanoparticles as sensors of the polymer for analytical purposes. The limit of detection for chitosan biopolymer is 69nM. The optimum pH for the interaction between the biopolymer and the nanoparticles is found at a value of 6.4, obtained from spectrophotometric measurements and applying a deconvolution analysis of the experimental data. A simple model based on molecular surface electrostatic interactions is proposed to understand the pH dependence of the investigated system. Copyright © 2014 Elsevier Inc. All rights reserved.
Sorption behavior of nano-TiO2 for the removal of selenium ions from aqueous solution.
Zhang, Lei; Liu, Na; Yang, Lijun; Lin, Qing
2009-10-30
Titanium dioxide nanoparticles were employed for the sorption of selenium ions from aqueous solution. The process was studied in detail by varying the sorption time, pH, and temperature. The sorption was found to be fast, and to reach equilibrium basically within 5.0 min. The sorption has been optimized with respect to the pH, maximum sorption has been achieved from solution of pH 2-6. Sorbed Se(IV) and Se(VI) were desorbed with 2.0 mL 0.1 mol L(-1) NaOH. The kinetics and thermodynamics of the sorption of Se(IV) onto nano-TiO2 have been studied. The kinetic experimental data properly correlate with the second-order kinetic model (k(2)=0.69 g mg(-1) min(-1), 293 K). The overall rate process appears to be influenced by both boundary layer diffusion and intraparticle diffusion. The sorption data could be well interpreted by the Langmuir sorption isotherm. The mean energy of adsorption (14.46 kJ mol(-1)) was calculated from the Dubinin-Radushkevich (D-R) adsorption isotherm at room temperature. The thermodynamic parameters for the sorption were also determined, and the DeltaH(0) and DeltaG(0) values indicate exothermic behavior.
Kelly, Charlene N.; Peltz, Christopher D.; Stanton, Mark R.; Rutherford, David W.; Rostad, Colleen E.
2014-01-01
Waste rock piles from historic mining activities remain unvegetated as a result of metal toxicity and high acidity. Biochar has been proposed as a low-cost remediation strategy to increase soil pH and reduce leaching of toxic elements, and improve plant establishment. In this laboratory column study, biochar made from beetle-killed pine wood was assessed for utility as a soil amendment by mixing soil material from two mine sites collected near Silverton, Colorado, USA with four application rates of biochar (0%, 10%, 20%, 30% vol:vol). Columns were leached seven times over 65 days and leachate pH and concentration of toxic elements and base cations were measured at each leaching. Nutrient availability and soil physical and biological parameters were determined following the incubation period. We investigated the hypotheses that biochar incorporation into acidic mine materials will (1) reduce toxic element concentrations in leaching solution, (2) improve soil parameters (i.e. increase nutrient and water holding capacity and pH, and decrease compaction), and (3) increase microbial populations and activity. Biochar directly increased soil pH (from 3.33 to 3.63 and from 4.07 to 4.77 in the two materials) and organic matter content, and decreased bulk density and extractable salt content in both mine materials, and increased nitrate availability in one material. No changes in microbial population or activity were detected in either mine material upon biochar application. In leachate solution, biochar increased base cations from both materials and reduced the concentrations of Al, Cd, Cu, Pb, and Zn in leachate solution from one material. However, in the material with greater toxic element content, biochar did not reduce concentrations of any measured dissolved toxic elements in leachate and resulted in a potentially detrimental release of Cd and Zn into solution at concentrations above that of the pure mine material. The length of time of effectiveness and specific sorption by biochar is variable by element and the toxic element concentration and acidity of the initial mine material.
Gravity-driven pH adjustment for site-specific protein pKa measurement by solution-state NMR
NASA Astrophysics Data System (ADS)
Li, Wei
2017-12-01
To automate pH adjustment in site-specific protein pKa measurement by solution-state NMR, I present a funnel with two caps for the standard 5 mm NMR tube. The novelty of this simple-to-build and inexpensive apparatus is that it allows automatic gravity-driven pH adjustment within the magnet, and consequently results in a fully automated NMR-monitored pH titration without any hardware modification on the NMR spectrometer.
Improving microalgal growth with small bubbles in a raceway pond with swing gas aerators.
Yang, Zongbo; Cheng, Jun; Liu, Jianzhong; Zhou, Junhu; Cen, Kefa
2016-09-01
A novel swing gas aerator was developed to generate small bubbles for improving the mass transfer coefficient and microalgal growth rate in a raceway pond. A high-speed photography system (HSP) was used to measure the bubble diameter and generation time, and online precise dissolved oxygen probes and pH probes were used to measure the mass transfer coefficient and mixing time. Bubble generation time and diameter decreased by 21% and 9%, respectively, when rubber gas aerators were swung in the microalgae solution. When water pump power and gas aeration rate increased in a raceway pond with swing gas aerators and oscillating baffles (SGAOB), bubble generation time and diameter decreased but solution velocity and mass transfer coefficient increased. The mass transfer coefficient increased by 25% and the solution velocity increased by 11% when SGAOB was used, and the microalgal biomass yield increased by 18%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Microsphere morphology tuning and photo-luminescence properties of monoclinic Y2WO6
NASA Astrophysics Data System (ADS)
Gao, Hong; Bai, Yulong; Zhang, Junying; Tang, Zilong
2015-04-01
Effects of the solution pH value and reaction time on the precursor morphology and photoluminescence properties are investigated for hydrothermally prepared monoclinic Y2WO6 phosphors. In the near-neutral environment, sodium dodecyl benzene sulfonate (SDBS) surfactant forms small microspheres micelles as template to synthesize microspherical precursor. H+ ions concentration affects the arrangement of negative ionic surfactant SDBS. As a result, jujube-liked and popcorn-like loose microspheres formed at low pH value. When the pH value is 5.2 and the hydrothermal reaction time reaches 24 h, respectively, the strongest luminescent intensity can be obtained. Under this condition, the precursor presented regular microsphere with diameter of 4.0 μm. After high-temperature heat treatment, the obtained phosphor particles still exhibit microsphere-like shape. Therefore, we provide an effective method to tune the morphology of Y2WO6 phosphors and study the relationship between morphology and luminescent performance.
Kinetics and Equilibrium of Fe3+ Ions Adsorption on Carbon Nanofibers
NASA Astrophysics Data System (ADS)
Alimin; Agusu, La; Ahmad, L. O.; Kadidae, L. O.; Ramadhan, L.; Nurdin, M.; Isdayanti, N.; Asria; Aprilia M, P.; Hasrudin
2018-05-01
Generally, the interaction between metal ions and adsorbent is governed by many factors including; concentration of metal ions, interaction time and solution pH. In this work, we applied liquid phase adsorption for studying the interaction between Fe3+ ions and Carbon Nanofibers (CNFs) irradiated by ultrasonic waves. Kinetics and isotherms model of the Fe3+ ion adsorption was investigated by varying contact time and pH. We found that the Fe3+ ions were efficiently adsorbed on CNFs for 0.5 h in acidic pH of around 5. In order to obtain the best-fitted isotherms model, Langmuir and Freundlich’s isotherms were used in this work. The adsorption equilibrium Fe3+ metal ions on CNFs tend to follow Langmuir. Adsorption kinetics of Fe3+ ions on CNFs were investigated by using both pseudo-first and pseudo-second orders. The adsorption kinetics coincided well with the pseudo-second-order.
Local environment around gold (III) in aqueous chloride solutions: An EXAFS spectroscopy study
NASA Astrophysics Data System (ADS)
Farges, Franã§Ois; Sharps, Julia A.; Brown, Gordon E., Jr.
1993-03-01
The local environment around Au (III) in aqueous solutions containing 1 M NaCl was determined as a function of pH and Au concentration using X-ray absorption spectroscopy (XAS) at ambient temperature and pressure. The solution Au concentrations studied were 10 - to 10 -3 M and the pH ranged between 2 and 9.2. No significant changes of Au speciation were detected with increasing Au concentration; however, major speciation changes were caused by variations in pH. At pH = 2, Au is coordinated by four Cl atoms ( mean d [AuCl] = 2.28 -2.29 ± 0.01 Å), whereas at pH 7.5 and 9.2, Au is coordinated by three Cl and one O (or OH) and by two Cl and two O (or OH), respectively ( mean d[AuCl] = 2.28 ± 0.02 Å; mean d[AuO or AuOH] = 1.97 ± 0.02 Å), indicating replacement of Cl by O (or OH) with increasing pH. In all solutions studied, the number of first-neighbors around Au(III) is close to four. XANES analysis suggests the presence of a square-planar geometry for AuX 4 ( X = Cl, O) at all pH values studied. These results are in excellent agreement with those from our previous Raman, resonance Raman, and UV/visible spectroscopy study of gold(III)-chloride solutions (PECK et al., 1991), which found that AuCl 4-, AuCl 3(OH) -, and AuCl 2(OH) 2- are the majority species in the pH ranges 2-6, 6-8.5, and 8.5-11, respectively. We did not find evidence for Au(I)Cl 2- or Au(I)Cl(OH) - complexes in our pH 7.5 and 9.2 solutions, as was recently suggested by PAN and WOOD (1991) for acidic gold chloride solutions at temperatures > 100°C, although we can't rule these complexes out as minority species (<10% of the total Au in solution). Our EXAFS results also provide the first direct evidence for Cl second neighbors around AuCl 4- complexes in the most acidic solutions studied ( pH = 2 and 4.5). These second-neighbor Cl atoms were also detected at low Au concentrations (10 -3 M) and are similar in number and arrangement to those observed in crystalline KAuCL 4·2H 2O (two Cl at a mean d[Au-Cl(2)] = 4.42 ± 0.03 Å). No evidence was found for second-neighbor Au atoms, which indicates little or no Au polymers or colloidal particles in any of the solutions studied. Our EXAFS results are in broad agreement with earlier predictions of Au speciation based on a variety of chemical measurements. Moreover, they directly confirm that mixed chloro-hydroxo Au (III) complexes are more stable than predicted on the basis of thermodynamically estimated stability constants.
Luo, Y M; Christie, P; Baker, A J
2000-07-01
Temporal changes in soil solution properties and metal speciation were studied in non-rhizosphere soil and in the rhizosphere of the hyperaccumulator Thlaspi caerulescens J. & C. Presl (population from Prayon, Belgium) grown in a Zn- and Cd-contaminated soil. This paper focuses on soil solution Zn and pH dynamics during phytoextraction. The concentration of Zn in both non-rhizosphere and rhizosphere soil solutions decreased from 23 mg/l at the beginning to 2 mg/l at the end of the experiment (84 days after transplanting of seedlings), mainly due to chemical sorption. There was no significant difference in overall Zn concentration between the planted and the unplanted soil solutions (P > 0.05). Soil solution pH decreased initially and then increased slightly in both planted and unplanted soil zones. From 60 to 84 days after transplanting, the pH of the rhizosphere soil solution was higher than that of non-rhizosphere soil solution (P<0.05). Zn uptake by the hyperaccumulator plants was 8.8 mg per pot (each containing 1 kg oven-dry soil) on average. The data indicate that the potential of T. caerulescens to remove Zn from contaminated soil may not be related to acidification of the rhizosphere.
Coeval Formation of Aqueous Minerals on Mars
NASA Astrophysics Data System (ADS)
Fairen, A.; Uceda, E.; Gil, C.; Palmero Rodriguez, A.; Gago-Duport, L.
2015-12-01
Understanding the geochemical conditions on early Mars requires an explanation for the presence of sulfates and phyllosilicates, which must be also consistent with the absence of widespread sedimentary carbonates. In addition, sulfates and phyllosilicates do not generally occur together on Mars, which has been interpreted as a marker for detached mineral formation due to differing planetary environmental conditions separated dramatically, either in time or in space. Here, thermodynamic equilibrium calculations are used to determine the stability boundaries for phyllosilicates, ferrous and ferric sulfates, carbonates and iron oxyhydroxides precipitation on early Mars, at different atmospheric CO2 pressures and both under reducing and oxidizing conditions. Results suggest that phyllosilicates formed in mildly acidic to alkaline aqueous solutions, with a pH>4 for nontronite and a pH>6 for other smectites with low content in Fe and Mg (montmorillonite, saponite). Sulfate deposition dominates in solutions moderately to highly acidic, with a pH<6 conducive to the synthesis of kieserite. In the overlapping phyllosilicates/sulfates pH range, between 4 and 6, a competition for Mg between nontronite and kieserite is expected, and the formation of nontronite would be favored in areas where SiO2 activity in surface waters was high as a result of intense weathering of the early basaltic crust. Carbonates formed at pH>6, overlapping with the synthesis of low-Fe-Mg smectites. Model calculations anticipate the co-precipitation of smectites and siderite or any alteration product that could have resulted from the later substitution of Fe in siderite, such as Mg- or Mn-carbonate, triggering a competition for Mg between magnesite and low-Fe-Mg smectites. As expected, the model does not predict coeval synthesis of carbonates and sulfates. Goethite and other oxyhydroxides precipitate at pH below 2, a range at which jarosite and goethite are the expected iron-bearing phases. These results suggest that the major water-alteration products on the Martian surface were deposited simultaneously in space and in time, creating diverse geochemical conditions over the entire surface of a cold Mars during the wet Noachian/Hesperian times.
Ganss, Carolina; Lussi, Adrian; Peutzfeldt, Anne; Naguib Attia, Nader; Schlueter, Nadine
2015-01-01
For preventing erosive wear in dentine, coating with adhesives has been suggested as an alternative to fluoridation. However, clinical studies have revealed limited efficacy. As there is first evidence that Sn2+ increases bond strength of the adhesive Clearfil SE (Kuraray), the aim of the present study was to investigate whether pre-treatment with different Sn2+/F− solutions improves the durability of Clearfil SE coatings. Dentine samples (eight groups, n=16/group) were freed of smear layer (0.5% citric acid, 10 s), treated (15 s) either with no solution (control), aminefluoride (AmF, 500 ppm F−, pH 4.5), SnCl2 (800/1600 ppm Sn2+; pH 1.5), SnCl2/AmF (500 ppm F−, 800 ppm Sn2+, pH 1.5/3.0/4.5), or Elmex Erosion Protection Rinse (EP, 500 ppm F−, 800 ppm Sn2+, pH 4.5; GABA International), then rinsed with water (15 s) and individually covered with Clearfil SE. Subsequently the specimens were subjected to an erosion/abrasion protocol consisting of 1320 cycles of immersion in 0.5% citric acid (5°C/55°C; 2 min) and automated brushing (15 s, 200 g, NaF-toothpaste, RDA 80). As the coatings proved stable up to 1320 cycles, 60 modified cycles (brushing time 30 min/cycle) were added. Wear was measured profilometrically. After SnCl2/AmF, pH 4.5 or EP pre-treatment all except one coating survived. In the other groups, almost all coatings were lost and there was no significant difference to the control group. Pre-treatment with a Sn2+/F− solution at pH 4.5 seems able to improve the durability of adhesive coatings, rendering these an attractive option in preventing erosive wear in dentine. PMID:26075906
Basharat, Meer; deSouza, Nandita M; Parkes, Harold G; Payne, Geoffrey S
2016-09-01
To estimate the exchange rates of labile (1) H in citrate and spermine, metabolites present in prostatic secretions, to predict the size of the citrate and spermine CEST effects in vivo. CEST z-spectra were acquired at high-field [11.7 Tesla (T)] from citrate and spermine solutions at physiological pH (6.5) using saturation power 6 μT. CEST was performed at different temperatures to determine exchange regimes (slow, intermediate or fast). For low pH solutions of spermine, exchange rates were estimated from resonance line width, fitting z-spectra using the Bloch equations incorporating exchange, and using quantifying exchange using saturation time experiments (QUEST). These rates were extrapolated to physiological pH. Citrate showed little CEST effect at pH 6.5 and temperature (T) = 310 K (maximum 0.001% mM(-1) ), indicating fast exchange, whereas spermine showed greater CEST effects (maximum 0.2% mM(-1) ) indicating intermediate-to-fast exchange. Extrapolating data acquired from low pH spermine solutions predicts exchange rates at pH 6.5 and T of 310 K of at least 2 × 10(4) s(-1) . Citrate and spermine show minimal CEST effects at 11.7T even using high saturation power. These effects would be much less than 2% at clinical field-strengths due to relatively faster exchange and would be masked by CEST from proteins. Magn Reson Med 76:742-746, 2016. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2015 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Dolomite surface speciation and reactivity in aquatic systems
NASA Astrophysics Data System (ADS)
Pokrovsky, Oleg S.; Schott, Jacques; Thomas, Fabien
1999-10-01
The surface charge of dolomite (CaMg(CO3)2) was measured as a function of pH (6.5-11.5), pCO2 (10-3.5, 0.01, and 0.96 atm) and ionic strength (0.01, 0.1, and 0.5 M NaCl) using potentiometric titrations in a limited residence time reactor. Dolomite zeta potential (ζ) was determined using streaming potential and electrophoresis techniques at pH 2 to 12 in solutions having ionic strengths from 0.001 to 0.1 M NaCl as a function of aqueous Ca2+, Mg2+, and CO32- concentrations. The point of zero charge (PZC) and isoelectric point (IEP) of dolomite are the same (pH ∼8 at pCO2 ∼10-3.5 atm) and very close to those of calcite and magnesite. On the basis of these results, a surface complexation model (SCM) is proposed that postulates the presence of three distinct primary hydration sites: >CO3H°, >CaOH°, and >MgOH°. The intrinsic stability constants of dolomite surface reactions were determined by fitting the pH dependence of the surface charge and taking into account the isoelectric points and ζ-potential values for a wide range of solution compositions. In most natural aquatic environments, dolomite surface speciation can be modeled using the following species: >CO3-, >CO3Me+, >MeOH2+, >MeHCO3o, and >MeCO3-, where Me = Ca, Mg. The speciation model presented in this study allows description of metal and ligand adsorption onto dolomite surface and provides new insights on the mechanisms that control dolomite dissolution/crystallization in aqueous solutions. In particular, it is shown that dolomite dissolution is controlled by the protonation of >CO3H° surface complexes at pH < 6 and by hydrolysis of >MeOH2+ groups at higher pH.
Hassanein, Naziha M.; Abd El-Hay Ibrahim, Hussein; Abd El-Baky, Doaa H.
2017-01-01
The ability of dead cells of endophytic Drechslera hawaiiensis of Morus alba L. grown in heavy metals habitats for bioremoval of cadmium (Cd2+), copper (Cu2+), and lead (Pb2+) in aqueous solution was evaluated under different conditions. Whereas the highest extent of Cd2+ and Cu2+ removal and uptake occurred at pH 8 as well as Pb2+ occurred at neutral pH (6–7) after equilibrium time 10 min. Initial concentration 30 mg/L of Cd2+ for 10 min contact time and 50 to 90 mg/L of Pb2+ and Cu2+ supported the highest biosorption after optimal contact time of 30 min achieved with biomass dose equal to 5 mg of dried died biomass of D. hawaiiensis. The maximum removal of Cd2+, Cu2+, and Pb2+ equal to 100%, 100%, and 99.6% with uptake capacity estimated to be 0.28, 2.33, and 9.63 mg/g from real industrial wastewater, respectively were achieved within 3 hr contact time at pH 7.0, 7.0, and 6.0, respectively by using the dead biomass of D. hawaiiensis compared to 94.7%, 98%, and 99.26% removal with uptake equal to 0.264, 2.3, and 9.58 mg/g of Cd2+, Cu2+, and Pb2+, respectively with the living cells of the strain under the same conditions. The biosorbent was analyzed by Fourier Transformer Infrared Spectroscopy (FT-IR) analysis to identify the various functional groups contributing in the sorption process. From FT-IR spectra analysis, hydroxyl and amides were the major functional groups contributed in biosorption process. It was concluded that endophytic D. hawaiiensis biomass can be used potentially as biosorbent for removing Cd2+, Cu2+, and Pb2+ in aqueous solutions. PMID:28781539
Hosny, Khaled Mohamed
2009-01-01
Ofloxacin, available as ophthalmic solution, has two major problems: first, it needs frequent administration every 4 hours or even every 1 hour to treat severe eye infection; second, there is formation of white crystalline deposit on cornea due to its pH-dependent solubility, which is very low at pH of corneal fluid. In order to provide a solution to previous problems, ofloxacin in this study is prepared as topically effective in situ thermosensitive prolonged release liposomal hydrogel. Two preparation procedures were carried out, leading to the formation of multilamellar vesicles (MLVs) and reverse-phase evaporation vesicles (REVs) at pH 7.4. Effects of method of preparation, lipid content, and charge inducers on encapsulation efficiency were studied. For the preparation of in situ thermosensitive hydrogel, chitosan/beta-glycerophosphate system was synthesized and used as carrier for ofloxacin liposomes. The effect of addition of liposomes on gelation temperature, gelation time, and rheological behaviors of the hydrogel were evaluated. In vitro transcorneal permeation was also determined. MLVs entrapped greater amount of ofloxacin than REVs liposomes at pH 7.4; drug loading was increased by including charge-inducing agent and by increasing cholesterol content until a certain limit. The gelation time was decreased by the addition of liposomes into the hydrogel. The prepared liposomal hydrogel enhances the transcorneal permeation sevenfold more than the aqueous solution. These results suggested that the in situ thermosensitive ofloxacin liposomal hydrogel ensures steady and prolonged transcorneal permeation, which improves the ocular bioavailability, minimizes the need for frequent administration, and decreases the ocular side effect of ofloxacin.
Form and stability of aluminum hydroxide complexes in dilute solution
Hem, John David; Roberson, Charles Elmer
1967-01-01
Laboratory studies of solutions 4.53 x 10 -4 to 4.5 x 10 -5 molal (12.2-1.2 ppm) in aluminum, in 0.01 molal sodium perchlorate, were conducted to obtain information as to the probable behavior of aluminum in natural water. When the solutions were brought to pH 7.5-9.5 and allowed to stand for 24 hours, a precipitate was obtained which was virtually amorphous as shown by X-rays, and which had a solubility equivalent to that of boehmite. This precipitate had a hydrolysis constant (*Ks4) of 1.93 x 10 -13a. When solutions were allowed to stead at this pH range for 10 days, their precipitates gave the X-ray pattern of bayerite (*Ks4 = 1.11 > (10- 4). These hydrolysis constants were obtained at 25?C. and corrected to zero ionic strength and are in close agreement with other published values. The predominant dissolved form in this pH range is Al(OH) -4. Below neutral pH (7.0) the dissolved aluminum species consist of octahedral units in which each aluminum ion is surrounded by six water molecules or hydroxide ions. Single units such as Al(OH2)6 + 3 and AlOH(OH2)5+2 are most abundant below pH 5.0, and where the molar ratio (r) of combined hydroxide to total dissolved aluminum is low. When r is greater than 1.0, polymerization of the octahedral units occurs. When r is between 2.0 and 3.0, solutions aged for 10 days or more contained colloidal particles between 0.10 and 0.45 ? in diameter. Particles whose diameters were greater than 0.10 ? were identified by X-ray diffraction as gibbsite. Particles smaller than 0.10 ? were also present and were shown by means of the electron microscope to have a hexagonal crystal pattern. Structured material consisting of sheets of coalesced six-membered rings of aluminum ions held together by double OH bridges has a distinctive kinetic behavior. This property was used to determine amounts of polymerized material in solutions having r between 1.0 and 3.0 after aging times ranging from a few hours to more than 4 months. Aging increased the size and orderliness of the polymeric aggregates and was accompanied by a decrease in the pH of the solution. The kinetic experiments and stoichiometric data for solutions aged for long periods provided a means of determining activities of polymerized aluminum. From these values the solubility product for microcrystalline gibbsite was determined to be 2.24 x 10 -3, and its free energy of formation, -? 272.3 0.4 kcal per mole. Where polymerization was observed, the process did not stop with small polynuclear complexes containing a few aluminum ions, but proceeded with aging until macromolecules or colloidal-sized particles were formed.
Relationship of Cell Sap pH to Organic Acid Change During Ion Uptake 1
Hiatt, A. J.
1967-01-01
Excised roots of barley (Hordeum vulgare, var. Campana) were incubated in KCl, K2SO4, CaCl2, and NaCl solutions at concentrations of 10−5 to 10−2 n. Changes in substrate solution pH, cell sap pH, and organic acid content of the roots were related to differences in cation and anion absorption. The pH of expressed sap of roots increased when cations were absorbed in excess of anions and decreased when anions were absorbed in excess of cations. The pH of the cell sap shifted in response to imbalances in cation and anion uptake in salt solutions as dilute as 10−5 n. Changes in cell sap pH were detectable within 15 minutes after the roots were placed in 10−3 n K2SO4. Organic acid changes in the roots were proportional to expressed sap pH changes induced by unbalanced ion uptake. Changes in organic acid content in response to differential cation and anion uptake appear to be associated with the low-salt component of ion uptake. PMID:16656506
Synthesis and formation mechanism of pinnoite by the phase transition process
NASA Astrophysics Data System (ADS)
Lin, Feng; Dong, Yaping; Peng, Jiaoyu; Wang, Liping; Li, Wu
2016-06-01
Pinnoite (MgB2O(OH)6) for the first time was synthesized using the solid-liquid-solid conversion method. The effects of reaction time, pH value and concentrations of magnesium and borate were investigated. Pinnoite was synthesized under the optimum condition of 8 mmol hungtsaoite and 1% boric acid solution at 80 °C. The products were determined using X-ray diffraction, Fourier-transform infrared spectroscopy, TG-DSC and a UV-vis spectrometer. The change processes of the surface morphology of pinnoite were investigated using scanning electron microscopy. In addition, the formation mechanism of pinnoite was discussed according to the changes in the content of precipitation and pH value.
Jaafarzadeh, Neamat; Amiri, Hoda; Ahmadi, Mehdi
2012-01-01
This paper describes an experimental design technique for the modification of volcanic ash with Fenton reagent (FMVA) to be used as a natural adsorbent in the removal of As(III) and As(V) from aqueous solution. The influence of pH, contact time and Fe(2+)/H2O2 on arsenic removal by the modified volcanic ash was investigated. It was observed that the arsenic removal efficiency was influenced by two of these parameters. The Fe(2+)/H2O2 ratio is an important factor that affects both As(III) and As(V) adsorption (P = 0.000). The pH affects As(V) adsorption (P = 0.003) more significantly than As (III) adsorption (P = 0.02). It was observed that the maximum As(III) adsorption by the FMVA was obtained at pH 2, Fe(+2)/H2O2 = 0.06 and 30 min of contact time (39 microg As(III) per mg FMVA), whereas the maximum As(V) adsorption was obtained under the conditions of pH 5, Fe(+2)/H2O2 = 0.06 and 30 min of contact time (41 microg As(V) per mg FMVA).
Karak, Tanmoy; Paul, Ranjit Kumar; Das, Sampa; Das, Dilip K; Dutta, Amrit Kumar; Boruah, Romesh K
2015-11-01
A study on the sorption kinetics of Cd from soil solution to soils was conducted to assess the persistence of Cd in soil solution as it is related to the leaching, bioavailability, and potential toxicity of Cd. The kinetics of Cd sorption on two non-contaminated alkaline soils from Canning (22° 18' 48.02″ N and 88° 39' 29.0″ E) and Lakshmikantapur (22° 06' 16.61″ N and 88° 19' 08.66″ E) of South 24 Parganas, West Bengal, India, were studied using conventional batch experiment. The variable soil suspension parameters were pH (4.00, 6.00, 8.18, and 9.00), temperatures (308, 318, and 328 K) and Cd concentrations (5-100 mg L(-1)). The average rate coefficient (kavg) and half-life (t1/2) values indicate that the persistence of Cd in soil solution is influenced by both temperature and soil suspension pH. The concentration of Cd in soil solution decreases with increase of temperature; therefore, Cd sorption on the soil-solution interface is an endothermic one. Higher pH decreases the t 1/2 of Cd in soil solution, indicating that higher pH (alkaline) is not a serious concern in Cd toxicity than lower pH (acidic). Based on the energy of activation (Ea) values, Cd sorption in acidic pH (14.76±0.29 to 64.45±4.50 kJ mol(-1)) is a surface control phenomenon and in alkaline pH (9.33±0.09 to 44.60±2.01 kJ mol(-1)) is a diffusion control phenomenon The enthalpy of activation (ΔH∓) values were found to be between 7.28 and 61.73 kJ mol(-1). Additionally, higher positive energy of activation (ΔG∓) values (46.82±2.01 to 94.47±2.36 kJ mol(-1)) suggested that there is an energy barrier for product formation.
Rare earth elements mobility processes in an AMD-affected estuary: Huelva Estuary (SW Spain).
Lecomte, K L; Sarmiento, A M; Borrego, J; Nieto, J M
2017-08-15
Huelva Estuary is a transition zone where REE-rich acidic waters interact with saline-alkaline seawater. This mixing process influences the geochemical and mineralogical characteristics of particulate and dissolved fractions. The Tinto River has >11,000μgL -1 dissolved REE (pH=1.66), whereas seawater only reaches 8.75·10 -2 μgL -1 dissolved REE (pH=7.87). REE-normalized patterns in "pH<6 solutions" are parallel and show similarities, diminishing their concentration as pH increases. Sequential extraction performed on the generated precipitates of mixed solutions indicates that most REE are associated to the residual phase. In a second order, REE are associated with soluble salts at pH3 and 3.5 whereas in sediments generated at pH4 and 5, they are distributed in salts (1° extraction), poorly crystallized Fe-bearing minerals (schwertmannite, 3° extraction) and well crystallized Fe-bearing minerals (goethite - hematite, 4° extraction). Finally, precipitated REE are highest at pH6 newly formed minerals with a release to solution in higher pH. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hermkens, Niels K J; Feiters, Martin C; Rutjes, Floris P J T; Wijmenga, Sybren S; Tessari, Marco
2017-03-01
SABRE (Signal Amplification By Reversible Exchange) is a nuclear spin hyperpolarization technique based on the reversible concurrent binding of small molecules and para-hydrogen (p-H 2 ) to an iridium metal complex in solution. At low magnetic field, spontaneous conversion of p-H 2 spin order to enhanced longitudinal magnetization of the nuclear spins of the other ligands occurs. Subsequent complex dissociation results in hyperpolarized substrate molecules in solution. The lifetime of this complex plays a crucial role in attained SABRE NMR signal enhancements. Depending on the ligands, vastly different dissociation rates have been previously measured using EXSY or selective inversion experiments. However, both these approaches are generally time-consuming due to the long recycle delays (up to 2min) necessary to reach thermal equilibrium for the nuclear spins of interest. In the cases of dilute solutions, signal averaging aggravates the problem, further extending the experimental time. Here, a new approach is proposed based on coherent hyperpolarization transfer to substrate protons in asymmetric complexes at high magnetic field. We have previously shown that such asymmetric complexes are important for application of SABRE to dilute substrates. Our results demonstrate that a series of high sensitivity EXSY spectra can be collected in a short experimental time thanks to the NMR signal enhancement and much shorter recycle delay. Copyright © 2017 Elsevier Inc. All rights reserved.
Biodurability of chrysotile and tremolite asbestos
NASA Astrophysics Data System (ADS)
Oze, C.; Solt, K.
2008-12-01
Chrysotile and tremolite asbestos represent two mineralogical categories of regulated asbestos commonly evaluated in epidemiological, toxicological, and pathological studies. Lung and digestive fluids are undersaturated with respect to chrysotile and tremolite asbestos (i.e. dissolution is thermodynamically favorable), where the dissolution kinetics control the durability of these minerals in respiratory and gastric systems. Here we examined the biodurability of chrysotile and tremolite asbestos in simulated body fluids (SBFs) as a function of mineral surface area over time. Batch experiments in simulated gastric fluid (SGF; HCl and NaCl solution at pH 1.2) and simulated lung fluid (SLF; a modified Gamble's solution at pH 7.4) were performed at 37°C over 720 hours. The rate-limiting step of Si release for both minerals was used to determine and compare dissolution rates. Chrysotile and tremolite asbestos are less biodurable in SGF compared to SLF. Based on equal suspension densities (surface area per volume of solution, m2 L- 1), chrysotile undergoes dissolution approximately 44 times faster than tremolite asbestos in SGF; however, amphibole asbestos dissolves approximately 6 times faster than chrysotile in SLF. Provided identical fiber dimensions, fiber dissolution models demonstrate that chrysotile is more biodurable in SLF and less biodurable in SGF compared to tremolite asbestos. Overall, the methodology employed here provides an alternative means to evaluate asbestos material fiber lifetimes based on mineral surface considerations.
Low glucose level and low pH alter the electrochemical function of human parietal pleura.
Kouritas, V K; Hatzoglou, C; Foroulis, C N; Hevas, A; Gourgoulianis, K I; Molyvdas, P A
2007-08-01
The aim of the present study was to investigate whether low glucose and pH level, which are usually measured in complicated pleural effusions, alter the electrochemical function of healthy human parietal pleura. Parietal pleural pieces were stripped from 66 patients during thoracic surgery and were mounted in Ussing chambers. Krebs' solutions containing different glucose levels (0, 40 and 100 mg) and balanced at different pH levels (7.4, 7.3 and 7.2) were added to the pleural cavity surface of the pieces. Transmesothelial potential difference was measured at various time-points as an electrophysiological variable and transmesothelial resistance (R(TM)) was calculated using Ohm's law. When normal-glucose Krebs at pH 7.45 was used, R(TM) remained unchanged over time, but when low-glucose Krebs was used, R(TM) decreased. Krebs without glucose caused the greatest decrease in R(TM). Use of low-pH Krebs decreased R(TM). The lower the pH of the Krebs, the faster the decrease in R(TM) and the greater the effect. The decrease in R(TM) was greater with low-pH than with low-glucose Krebs. Low glucose and low pH caused an additive decrease in R(TM). Low glucose concentration and low pH cause alteration of the electrochemical function of human parietal pleura and could act as agents that lead to further exudate progression.
Niu, Xiaopeng; Ruan, Renman; Xia, Liuyin; Li, Li; Sun, Heyun; Jia, Yan; Tan, Qiaoyi
2018-02-27
When it comes to Pb-Zn ores with high amounts of pyrite, the major problem encountered is the low separation efficiency between galena and pyrite. By virtue of high dosage of lime and collector sodium diethyl dithiocarbamate (DDTC), pyrite and zinc minerals are depressed, allowing the galena to be floated. However, there have been significant conflicting reports on the flotation behavior of galena at high pH. In this context, correlation of the surface adsorption and oxidation with the floatability difference of galena and pyrite in high-alkaline lime systems would be a key issue for process optimization. Captive bubble contact angle measurements were performed on freshly polished mineral surfaces in situ exposed to lime solutions of varying pH as a function of immersion time. Furthermore, single mineral microflotation tests were conducted. Both tests indicated that the degree of hydrophobicity on the surfaces of galena and pyrite increased in the presence of DDTC at natural or mild pulp pH. While in a saturated lime solution, at pH 12.5, DDTC only worked for galena, but not for pyrite. Surface chemistry analysis by time-of-flight secondary ion mass spectrometry (Tof-SIMS) confirmed the preference of DDTC on the galena surface at pH 12.5, which contributed to a merit recovery. Further important evidence through measurements of Tof-SIMS, ion chromatography, and high-performance liquid chromatography indicated that in high-alkaline lime systems, the merit floatability of galena could exclude the insignificant contribution of elemental sulfur (S 8 ) and was dominantly attributed by the strong adsorption of DDTC. In contrast, the poor flotation response of pyrite at high pH was due to the prevailing adsorption of CaOH + species. This study provides an important surface chemistry evidence for a better understanding of the mechanism on the better selectivity in the galena-pyrite separation adopting high-alkaline lime systems.
Dynamic light-scattering study of gelatin and aggregation of gastric mucin
NASA Astrophysics Data System (ADS)
Bansil, Rama; Cao, Xingxiang; Bhaskar, K. Ramakrishnan; LaMont, Jeffrey T.
1997-05-01
Dynamic light scattering studies show that concentration and pH play important roles in determining pig gastric mucin's (PGM) ability to aggregate and gel. At low concentrations, PGM macromolecules exist in solution predominantly in the form of monomers. At high concentrations, PGM macromolecules aggregate to form supra-macromolecular clusters. When the pH of the high concentration PGM solution is changed from 7.0 to 2.0, the system undergoes a sol-gel transition: from a solution of polydisperse aggregates to a gel. This pH and concentration dependent sol-gel transition of PGM solution may provide a mechanism for the mammalian stomach to protect itself against being digested by the gastric juice.
NASA Astrophysics Data System (ADS)
Pokrovsky, Oleg S.; Schott, Jacques
2004-01-01
Dissolution and precipitation rates of brucite (Mg(OH) 2) were measured at 25°C in a mixed-flow reactor as a function of pH (2.5 to 12), ionic strength (10 -4 to 3 M), saturation index (-12 < log Ω < 0.4) and aqueous magnesium concentrations (10 -6 to 5·10 -4 M). Brucite surface charge and isoelectric point (pH IEP) were determined by surface titrations in a limited residence time reactor and electrophoretic measurements, respectively. The pH of zero charge and pH IEP were close to 11. A two-pK, one site surface speciation model which assumes a constant capacitance of the electric double layer (5 F/m 2) and lack of dependence on ionic strength predicts the dominance of >MgOH 2+ species at pH < 8 and their progressive replacement by >MgOH° and >MgO - as pH increases to 10-12. Rates are proportional to the square of >MgOH 2+ surface concentration at pH from 2.5 to 12. In accord with surface speciation predictions, dissolution rates do not depend on ionic strength at pH 6.5 to 11. Brucite dissolution and precipitation rates at close to equilibrium conditions obeyed TST-derived rate laws. At constant saturation indices, brucite precipitation rates were proportional to the square of >MgOH 2+ concentration. The following rate equation, consistent with transition state theory, describes brucite dissolution and precipitation kinetics over a wide range of solution composition and chemical affinity: R=k Mg+ · {>MgOH 2+} 2 · (1-Ω 2) where kMg+ is the dissolution rate constant, {> i} is surface species concentration (mol/m 2), and Ω is the solution saturation index with respect to brucite. Measurements of nonsteady state brucite dissolution rates, in response to cycling the pH from 12 to 2 (pH-jump experiments), indicate the important role of surface hydroxylation — that leads to the formation of Mg oxo or -hydroxo complexes — in the formation of dissolution-active sites. Replacement of water molecules by these oxygen donor complexes in the Mg coordination sphere has a labilizing effect on the dynamics of the remaining water molecules and thus increases reaction rates.
Kang, Wanli; Wang, Pengxiang; Fan, Haiming; Yang, Hongbin; Dai, Caili; Yin, Xia; Zhao, Yilu; Guo, Shujun
2017-02-08
Responsive wormlike micelles are very useful in a number of applications, whereas it is still challenging to create dramatic viscosity changes in wormlike micellar systems. Here we developed a pH-responsive wormlike micellar system based on a noncovalent constructed surfactant, which is formed by the complexation of N-erucamidopropyl-N,N-dimethylamine (UC 22 AMPM) and citric acid at the molar ratio of 3 : 1 (EACA). The phase behavior, aggregate microstructure and viscoelasticity of EACA solutions were investigated by macroscopic appearance observation, rheological and cryo-TEM measurements. It was found that the phase behavior of EACA solutions undergoes transition from transparent viscoelastic fluids to opalescent solutions and then phase separation with white floaters upon increasing the pH. Upon increasing the pH from 2.03 to 6.17, the viscosity of wormlike micelles in the transparent solutions continuously increased and reached ∼683 000 mPa s at pH 6.17. As the pH was adjusted to 7.31, the opalescent solution shows a water-like flowing behaviour and the η 0 rapidly declines to ∼1 mPa s. Thus, dramatic viscosity changes of about 6 magnitudes can be triggered by varying the pH values without any deterioration of the EACA system. This drastic variation in rheological behavior is attributed to the pH dependent interaction between UC 22 AMPM and citric acid. Furthermore, the dependence on concentration and temperature of the rheological behavior of EACA solutions was also studied to assist in obtaining the desired pH-responsive viscosity changes.
Lee, Sang Mi; Shin, Gil-Ok; Park, Kyung Min; Chang, Pahn-Shick; Kim, Young-Suk
2013-01-01
Static headspace gas chromatographic (SHS-GC) analysis was performed to determine the release of 13 odorants in hydrocolloid model systems containing original or regio-selectively carboxylated cellulose at different pH values. The release of most odor compounds was decreased in the hydrocolloid solutions compared to control, with the amounts of 2-propanol, 3-methyl-1-butanol, and 2,3-butanedione released into the headspace being less than those of any other odor compound in the hydrocolloid model systems. However, there was no considerable difference between original cellulose-containing and carboxylated-cellulose containing systems in the release of most compounds, except for relatively long-chain esters such as ethyl caprylate and ethyl nonanoate. The release from the original and carboxylated cellulose solutions controlled to pH 10 was significantly higher than that from solutions adjusted to pH 4 and 7 in the case of some esters (ethyl acetate, methyl propionate, ethyl propionate, ethyl butyrate, butyl propionate, ethyl caproate) and alcohols (2-propanol, 3-methyl-1-butanol), in particular, ethyl butyrate and 3-methyl-1-butanol. In contrast, the release of 2,3-butanedione from both the original and carboxylated cellulose solutions was increased at pH 4 and 7 compared to that at pH 10 by about 70% and 130%, respectively. Our study demonstrated that the release of some odorants could be changed significantly by addition of both original and carboxylated cellulose in hydrocolloid model systems, but only minor effect was observed in pH of the solution. PMID:23447013
Russell, Allan E.
1974-01-01
Thermal stabilities of mature insoluble collagen, salt-precipitated fibrils of acid-soluble collagen and acid-soluble collagen in solution were compared as a function of acid pH. Both insoluble and precipitated collagens showed large parallel destabilization with decrease in pH, whereas the intrinsic stability of individual collagen molecules in dilute solution was comparatively unaffected. PMID:4478066
Gunasekera, Bhagya; Abou Diwan, Charbel; Altawallbeh, Ghaith; Kalil, Haitham; Maher, Shaimaa; Xu, Song; Bayachou, Mekki
2018-03-07
Nitric oxide (NO) release counteracts platelet aggregation and prevents the thrombosis cascade in the inner walls of blood vessels. NO-release coatings also prevent thrombus formation on the surface of blood-contacting medical devices. Our previous work has shown that inducible nitric oxide synthase (iNOS) films release NO fluxes upon enzymatic conversion of the substrate l-arginine. In this work, we report on the modulation of enzyme loading in layer-by-layer (LbL) thin films of inducible nitric oxide synthase oxygenase (iNOSoxy) on polyethylenimine (PEI). The layer of iNOSoxy is electrostatically adsorbed onto the PEI layer. The pH of the iNOSoxy solution affects the amount of enzyme adsorbed. The overall negative surface charge of iNOSoxy in solution depends on the pH and hence determines the density of adsorbed protein on the positively charged PEI layer. We used buffered iNOSoxy solutions adjusted to pHs 8.6 and 7.0, while saline PEI solution was used at pH 7.0. Atomic force microscopy imaging of the outermost layer shows higher protein adsorption with iNOSoxy at pH 8.6 than with a solution of iNOSoxy at pH 7.0. Graphite electrodes with PEI/iNOSoxy films show higher catalytic currents for nitric oxide reduction mediated by iNOSoxy. The higher enzyme loading translates into higher NO flux when the enzyme-modified surface is exposed to a solution containing the substrate and a source of electrons. Spectrophotometric assays showed higher NO fluxes with iNOSoxy/PEI films built at pH 8.6 than with films built at pH 7.0. Fourier transform infrared analysis of iNOSoxy adsorbed on PEI at pH 8.6 and 7.0 shows structural differences of iNOSoxy in films, which explains the observed changes in enzymatic activity. Our findings show that pH provides a strategy to optimize the NOS loading and enzyme activity in NOS-based LbL thin films, which enables improved NO release with minimum layers of PEI/NOS.
Formation of hydrotalcite in aqueous solutions and intercalation of ATP by anion exchange.
Tamura, Hiroki; Chiba, Jun; Ito, Masahiro; Takeda, Takashi; Kikkawa, Shinichi; Mawatari, Yasuteru; Tabata, Masayoshi
2006-08-15
The formation reaction and the intercalation of adenosine triphosphate (ATP) were studied for hydrotalcite (HT), a layered double hydroxide (LDH) of magnesium and aluminum. Hydrotalcite with nitrate ions in the interlayer (HT-NO(3)) was formed (A) by dropwise addition of a solution of magnesium and aluminum nitrates (pH ca. 3) to a sodium hydroxide solution (pH ca. 14) until the pH decreased from 14 to 10 and (B) by dropwise addition of the NaOH solution to the solution of magnesium and aluminum nitrates with pH increasing from 3 to 10. The precipitate obtained with method B was contaminated with aluminum hydroxide and the crystallinity of the product was low, possibly because aluminum hydroxide precipitates at pH 4 or 5 and remains even after HT-NO(3) forms at pH above 8. With method A, however, the precipitate was pure HT-NO(3) with increased crystallinity, since the solubility of aluminum hydroxide at pH above and around 10 is high as dissolved aluminate anions are stable in this high pH region, and there was no aluminum hydroxide contamination. The formed HT-NO(3) had a composition of [Mg(0.71)Al(0.29)(OH)(2)](NO(3))(0.29).0.58H(2)O. To intercalate ATP anions into the HT-NO(3), HT-NO(3) was dispersed in an ATP solution at pH 7. It was found that the interlayer nitrate ions were completely exchanged with ATP anions by ion exchange, and the interlayer distance expanded almost twice with a free space distance of 1.2 nm. The composition of HT-ATP was established as [Mg(0.68)Al(0.32)(OH)(2)](ATP)(0.080)0.88H(2)O. The increased distance could be explained with a calculated molecular configuration of the ATP as follows: An ATP molecule is bound to an interlayer surface with the triphosphate group, the adenosine group bends owing to its bond angles and projects into the interlayer to a height of 1 nm, and the adenosine groups aligned in the interlayer support the interlayer distance.
Xu, Xiao-Yu; Yan, Bing
2016-04-28
A pH sensor is fabricated via a reaction between an Al(III) salt and 2-aminoterephthalic acid in DMF which leads to a MOF (Al-MIL-101-NH2) with free amino groups. The Al-MIL-101-NH2 samples show good luminescence and an intact structure in aqueous solutions with pH ranging from 4.0 to 7.7. Given its exceptional stability and pH-dependent fluorescence intensity, Al-MIL-101-NH2 has been applied to fluorescent pH sensing. Significantly, in the whole experimental pH range (4.0-7.7), the fluorescence intensity almost increases with increasing pH (R(2) = 0.99688) which can be rationalized using a linear equation: I = 2.33 pH + 26.04. In addition, error analysis and cycling experiments have demonstrated the accuracy and utilizability of the sensor. In practical applications (PBS and lake water), Al-MIL-101-NH2 also manifests its analytical efficiency in pH sensing. And the samples can be easily isolated from an aqueous solution by incorporating Fe3O4 nanoparticles. Moreover, the possible sensing mechanism based on amino protonation is discussed in detail. This work is on of the few cases for integrated pH sensing systems in aqueous solution based on luminescent MOFs.
Caustic Precipitation of Plutonium and Uranium with Gadolinium as a Neutron Poison
DOE Office of Scientific and Technical Information (OSTI.GOV)
VISSER, ANN E.; BRONIKOWSKI, MICHAEL G.; RUDISILL, TRACY S.
2005-10-18
The caustic precipitation of plutonium (Pu) and uranium (U) from Pu and U-containing waste solutions has been investigated to determine whether gadolinium (Gd) could be used as a neutron poison for precipitation with greater than a fissile mass containing both Pu and enriched U. Precipitation experiments were performed using both process solution samples and simulant solutions with a range of 2.6-5.16 g/L U and 0-4.3:1 U:Pu. Analyses were performed on solutions at intermediate pH to determine the partitioning of elements for accident scenarios. When both Pu and U were present in the solution, precipitation began at pH 4.5 and bymore » pH 7, 99% of Pu and U had precipitated. When complete neutralization was achieved at pH > 14 with 1.2 M excess OH{sup -}, greater than 99% of Pu, U, and Gd had precipitated. At pH > 14, the particles sizes were larger and the distribution was a single mode. The ratio of hydrogen:fissile atoms in the precipitate was determined after both settling and centrifuging and indicates that sufficient water was associated with the precipitates to provide the needed neutron moderation for Gd to prevent a criticality in solutions containing up to 4.3:1 U:Pu and up to 5.16 g/L U.« less
ERIC Educational Resources Information Center
Jones, Richard C.
1993-01-01
Describes an activity to simulate the geometries of a spreading pathogen such as HIV throughout a generation. Students exchange "bodily fluids" three times and are then tested for the presence of "infection." Materials used include base solutions (NaOH or KOH), phenolphthalein (pH indicator), clear plastic cups, and an eye dropper. (PR)
Infrared spectrum analysis of the dissociated states of simple amino acids.
Sebben, Damien; Pendleton, Phillip
2014-11-11
In this work, we present detailed analyses of the dissociation of dilute aqueous solutions of glycine and of lysine over the range 1
Kamran, Sedigheh; Absalan, Ghodratollah; Asadi, Mozaffar
2015-12-01
In this paper, nanoparticles of Fe3O4 as well as their modified forms with different ionic liquids (IL-Fe3O4) were prepared and used for adsorption of lysozyme. The mean size and the surface morphology of the nanoparticles were characterized by TEM, XRD and FTIR techniques. Adsorption studies of lysozyme were performed under different experimental conditions in batch system on different modified magnetic nanoparticles such as, lysozyme concentration, pH of the solution, and contact time. Experimental results were obtained under the optimum operational conditions of pH 9.0 and a contact time of 10 min when initial protein concentrations of 0.05-2.0 mg mL(-1) were used. The isotherm evaluations revealed that the Langmuir model attained better fits to the equilibrium data than the Freundlich model. The maximum obtained adsorption capacities were 370.4, 400.0 500.0 and 526.3 mg of lysozyme for adsorption onto Fe3O4 and modified magnetic nanoparticles by [C4MIM][Br], [C6MIM][Br] and [C8MIM][Br] per gram of adsorbent, respectively. The Langmuir adsorption constants were 0.004, 0.019, 0.024 and 0.012 L mg(-1) for adsorptions of lysozyme onto Fe3O4 and modified magnetic nanoparticles by [C4MIM][Br], [C6MIM][Br] and [C8MIM][Br], respectively. The adsorption capacity of lysozyme was found to be dependent on its chemical structure, pH of the solution, temperature and type of ionic liquid as modifier. The applicability of two kinetic models including pseudo-first order and pseudo-second order model was estimated. Furthermore, the thermodynamic parameters were calculated. Protein could desorb from IL-Fe3O4 nanoparticles by using NaCl solution at pH 9.5 and was reused.
ISFET pH Sensitivity: Counter-Ions Play a Key Role.
Parizi, Kokab B; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H S Philip
2017-02-02
The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor.
ISFET pH Sensitivity: Counter-Ions Play a Key Role
Parizi, Kokab B.; Xu, Xiaoqing; Pal, Ashish; Hu, Xiaolin; Wong, H. S. Philip
2017-01-01
The Field Effect sensors are broadly used for detecting various target analytes in chemical and biological solutions. We report the conditions under which the pH sensitivity of an Ion Sensitive Field Effect transistor (ISFET) sensor can be significantly enhanced. Our theory and simulations show that by using pH buffer solutions containing counter-ions that are beyond a specific size, the sensor shows significantly higher sensitivity which can exceed the Nernst limit. We validate the theory by measuring the pH response of an extended gate ISFET pH sensor. The consistency and reproducibility of the measurement results have been recorded in hysteresis free and stable operations. Different conditions have been tested to confirm the accuracy and validity of our experiment results such as using different solutions, various oxide dielectrics as the sensing layer and off-the-shelf versus IC fabricated transistors as the basis of the ISFET sensor. PMID:28150700
[Efficiency of photodecomposition of trace NDMA in water by UV irradiation].
Xu, Bing-Bing; Chen, Zhong-Lin; Qi, Fei; Ma, Jun
2008-07-01
Efficiency of photodecomposition of trace NDMA by UV irradiation was investigated with analyzing the initial concentration of NDMA, solution pH, irradiation area, irradiation intensity and water quality effect on NDMA photolysis. NDMA could be effectively photodegraded by UV irradiation. The removal efficiency of NDMA was 97.5% after 5 min of UV irradiation. Effect of initial NDMA concentration on photodecomposition of NDMA was not remarkable. With pH value ascending, the removal rate of NDMA photodecomposition decreased. The yields of photoquantum were more under lower solution pH than that under higher pH. NDMA had fastest reaction rate at solution pH = 2.2. Removal efficiency of NDMA increased with the available irradiation area ascending. Increscent ultraviolet irradiation intensity was good for NDMA degradation. Water quality affected the removal of NDMA slightly. The removal efficiency of NDMA in tap water and Songhua River raw water were 96.7% and 94.8%, respectively.
NASA Technical Reports Server (NTRS)
Bugbee, B. G.; Salisbury, F. B.
1985-01-01
All buffering agents used to stabilize pH in hydroponic research have disadvantages. Inorganic buffers are absorbed and may become phytotoxic. Solid carbonate salts temporarily mitigate decreasing pH but provide almost no protection against increasing pH, and they alter nutrient absorption. Exchange resins are more effective, but we find that they remove magnesium and manganese from solution. We have tested 2(N-Morpholino)ethanesulfonic acid (MES) as a buffering agent at concentrations of 1 and 10 mol m-3 (1 and 10 mM) with beans, corn, lettuce, tomatoes, and wheat. MES appears to be biologically inert and does not interact significantly with other solution ions. Relative growth rates among controls and MES treatments were nearly identical for each species during the trial period. The pH was stabilized by 1 mol m-3 MES. This buffer warrants further consideration in nutrient research.