Smooth time-dependent receiver operating characteristic curve estimators.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan Carlos
2018-03-01
The receiver operating characteristic curve is a popular graphical method often used to study the diagnostic capacity of continuous (bio)markers. When the considered outcome is a time-dependent variable, two main extensions have been proposed: the cumulative/dynamic receiver operating characteristic curve and the incident/dynamic receiver operating characteristic curve. In both cases, the main problem for developing appropriate estimators is the estimation of the joint distribution of the variables time-to-event and marker. As usual, different approximations lead to different estimators. In this article, the authors explore the use of a bivariate kernel density estimator which accounts for censored observations in the sample and produces smooth estimators of the time-dependent receiver operating characteristic curves. The performance of the resulting cumulative/dynamic and incident/dynamic receiver operating characteristic curves is studied by means of Monte Carlo simulations. Additionally, the influence of the choice of the required smoothing parameters is explored. Finally, two real-applications are considered. An R package is also provided as a complement to this article.
Huang, Si-Si; Xie, Dong-Mei; Cai, Yi-Jing; Wu, Jian-Min; Chen, Rui-Chong; Wang, Xiao-Dong; Song, Mei; Zheng, Ming-Hua; Wang, Yu-Qun; Lin, Zhuo; Shi, Ke-Qing
2017-04-01
Hepatitis B virus (HBV) infection remains a major health problem and HBV-related-decompensated cirrhosis (HBV-DC) usually leads to a poor prognosis. Our aim was to determine the utility of inflammatory biomarkers in predicting mortality of HBV-DC. A total of 329 HBV-DC patients were enrolled. Survival estimates for the entire study population were generated using the Kaplan-Meier method. The prognostic values for model for end-stage liver disease (MELD) score, Child-Pugh score, and inflammatory biomarkers neutrophil/lymphocyte ratio, C-reactive protein-to-albumin ratio (CAR), and lymphocyte-to-monocyte ratio (LMR) for HBV-DC were compared using time-dependent receiver operating characteristic curves and time-dependent decision curves. The survival time was 23.1±15.8 months. Multivariate analysis identified age, CAR, LMR, and platelet count as prognostic independent risk factors. Kaplan-Meier analysis indicated that CAR of at least 1.0 (hazard ratio, 7.19; 95% confidence interval, 4.69-11.03), and LMR less than 1.9 (hazard ratio, 2.40; 95% confidence interval, 1.69-3.41) were independently associated with mortality of HBV-DC. The time-dependent receiver operating characteristic indicated that CAR showed the best performance in predicting mortality of HBV-DC compared with LMR, MELD score, and Child-Pugh score. The results were also confirmed by time-dependent decision curves. CAR and LMR were associated with the prognosis of HBV-DC. CAR was superior to LMR, MELD score, and Child-Pugh score in HBV-DC mortality prediction.
Design considerations for a LORAN-C timing receiver in a hostile signal to noise environment
NASA Technical Reports Server (NTRS)
Porter, J. W.; Bowell, J. R.; Price, G. E.
1981-01-01
The environment in which a LORAN-C Timing Receiver may function effectively depends to a large extent on the techniques utilized to insure that interfering signals within the pass band of the unit are neutralized. The baseline performance manually operated timing receivers is discussed and the basic design considerations and necessary parameters for an automatic unit utilizing today's technology are established. Actual performance data is presented comparing the results obtained from a present generation timing receiver against a new generation microprocessor controlled automatic acquisition receiver. The achievements possible in a wide range of signal to noise situations are demonstrated.
Nishikawa, Hiroki; Nishijima, Norihiro; Enomoto, Hirayuki; Sakamoto, Azusa; Nasu, Akihiro; Komekado, Hideyuki; Nishimura, Takashi; Kita, Ryuichi; Kimura, Toru; Iijima, Hiroko; Nishiguchi, Shuhei; Osaki, Yukio
2017-01-01
To investigate variables before sorafenib therapy on the clinical outcomes in hepatocellular carcinoma (HCC) patients receiving sorafenib and to further assess and compare the predictive performance of continuous parameters using time-dependent receiver operating characteristics (ROC) analysis. A total of 225 HCC patients were analyzed. We retrospectively examined factors related to overall survival (OS) and progression free survival (PFS) using univariate and multivariate analyses. Subsequently, we performed time-dependent ROC analysis of continuous parameters which were significant in the multivariate analysis in terms of OS and PFS. Total sum of area under the ROC in all time points (defined as TAAT score) in each case was calculated. Our cohort included 175 male and 50 female patients (median age, 72 years) and included 158 Child-Pugh A and 67 Child-Pugh B patients. The median OS time was 0.68 years, while the median PFS time was 0.24 years. On multivariate analysis, gender, body mass index (BMI), Child-Pugh classification, extrahepatic metastases, tumor burden, aspartate aminotransferase (AST) and alpha-fetoprotein (AFP) were identified as significant predictors of OS and ECOG-performance status, Child-Pugh classification and extrahepatic metastases were identified as significant predictors of PFS. Among three continuous variables (i.e., BMI, AST and AFP), AFP had the highest TAAT score for the entire cohort. In subgroup analyses, AFP had the highest TAAT score except for Child-Pugh B and female among three continuous variables. In continuous variables, AFP could have higher predictive accuracy for survival in HCC patients undergoing sorafenib therapy.
Estimating time-dependent ROC curves using data under prevalent sampling.
Li, Shanshan
2017-04-15
Prevalent sampling is frequently a convenient and economical sampling technique for the collection of time-to-event data and thus is commonly used in studies of the natural history of a disease. However, it is biased by design because it tends to recruit individuals with longer survival times. This paper considers estimation of time-dependent receiver operating characteristic curves when data are collected under prevalent sampling. To correct the sampling bias, we develop both nonparametric and semiparametric estimators using extended risk sets and the inverse probability weighting techniques. The proposed estimators are consistent and converge to Gaussian processes, while substantial bias may arise if standard estimators for right-censored data are used. To illustrate our method, we analyze data from an ovarian cancer study and estimate receiver operating characteristic curves that assess the accuracy of the composite markers in distinguishing subjects who died within 3-5 years from subjects who remained alive. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
System for near real-time crustal deformation monitoring
NASA Technical Reports Server (NTRS)
Macdoran, P. F. (Inventor)
1979-01-01
A system is described for use in detecting earth crustal deformation using an RF interferometer technique for such purposes as earthquake predictive research and eventual operational predictions. A lunar based RF transmission or transmissions from earth orbiting satellites are received at two locations on Earth, and a precise time dependent phase measurement is made of the RF signal as received at the two locations to determine two or three spatial parameters of the antenna relative positions. The received data are precisely time tagged and land-line routed to a central station for real-time phase comparison and analysis. By monitoring the antenna relative positions over an extended period of months or years, crustal deformation of the Earth can be detected.
Tada, Toshifumi; Kumada, Takashi; Toyoda, Hidenori; Tsuji, Kunihiko; Hiraoka, Atsushi; Tanaka, Junko
2017-02-01
Nucleos(t)ide analogue (NA) therapy has been reported to reduce the risk of hepatocellular carcinoma (HCC) development in patients with chronic hepatitis B (CHB). However, even during NA therapy, development of HCC has been observed in patients with CHB. Therefore, we clarified the predictive power of clinical factors for HCC incidence using receiver operating characteristic (ROC) analysis that takes time dependence into account. A total of 539 patients with CHB treated with NAs were enrolled. Univariate, multivariate, and time-dependent ROC curves for clinical factors associated with the development of HCC were analyzed. Eighty-one patients developed HCC during the follow-up period (median duration, 5.9 years). α-fetoprotein (AFP) and FIB-4 index at 24 weeks from the initiation of treatment and sex were significantly associated with HCC incidence according to the log-rank test. Cox proportional hazards models including the covariates of sex, hepatitis B genotype, basal core promoter mutations, AFP at 24 weeks, and FIB-4 index at 24 weeks showed that FIB-4 index >2.65 (HR, 5.03; 95% CI, 3.06-8.26; P < 0.001) and male sex were independently associated with HCC incidence. In addition, time-dependent ROC analysis showed that compared with AFP at 24 weeks, FIB-4 index at 24 weeks had higher predictive power for HCC incidence throughout the follow-up period. Elevated FIB-4 index at 24 weeks in patients with CHB receiving NA therapy is a risk factor for developing HCC. The FIB-4 index is an excellent predictor of HCC development. © 2016 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
NASA Technical Reports Server (NTRS)
Eppler, Dean B.
2013-01-01
The scientific success of any future human lunar exploration mission will be strongly dependent on design of both the systems and operations practices that underpin crew operations on the lunar surface. Inept surface mission preparation and design will either ensure poor science return, or will make achieving quality science operation unacceptably difficult for the crew and the mission operations and science teams. In particular, ensuring a robust system for managing real-time science information flow during surface operations, and ensuring the crews receive extensive field training in geological sciences, are as critical to mission success as reliable spacecraft and a competent operations team.
Time-dependent summary receiver operating characteristics for meta-analysis of prognostic studies.
Hattori, Satoshi; Zhou, Xiao-Hua
2016-11-20
Prognostic studies are widely conducted to examine whether biomarkers are associated with patient's prognoses and play important roles in medical decisions. Because findings from one prognostic study may be very limited, meta-analyses may be useful to obtain sound evidence. However, prognostic studies are often analyzed by relying on a study-specific cut-off value, which can lead to difficulty in applying the standard meta-analysis techniques. In this paper, we propose two methods to estimate a time-dependent version of the summary receiver operating characteristics curve for meta-analyses of prognostic studies with a right-censored time-to-event outcome. We introduce a bivariate normal model for the pair of time-dependent sensitivity and specificity and propose a method to form inferences based on summary statistics reported in published papers. This method provides a valid inference asymptotically. In addition, we consider a bivariate binomial model. To draw inferences from this bivariate binomial model, we introduce a multiple imputation method. The multiple imputation is found to be approximately proper multiple imputation, and thus the standard Rubin's variance formula is justified from a Bayesian view point. Our simulation study and application to a real dataset revealed that both methods work well with a moderate or large number of studies and the bivariate binomial model coupled with the multiple imputation outperforms the bivariate normal model with a small number of studies. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Gullà, F; Zambelli, P; Bergamaschi, A; Piccoli, B
2007-01-01
The aim of this study is the objective evaluation of the visual effort in 6 public traffic controllers (4 male, 2 female, mean age 29,6), by means of electronic equipment. The electronic equipment quantify the observation distance and the observation time for each controller's occupational visual field. The quantification of these parameters is obtained by the emission of ultrasound at 40 KHz from an emission sensor (placed by the VDT screen) and the ultrasound reception by means of a receiving sensor (placed on the operator's head). The travelling time of the ultrasound (US), as the air speed is known and costant (about 340 m/s), it is used to calculate the distance between the emitting and the receiving sensor. The results show that the visual acuity required is of average level, while accommodation's and convergence's effort vary from average to intense (depending on the visual characteristics of the operator considered), ranging from 26,41 and 43,92% of accommodation and convergence available in each operator. The time actually spent in "near observation within the c.v.p." (Tscr) was maintained in a range from 2h 54' and 4h 05'.
NASA Astrophysics Data System (ADS)
Cannon, Paul S.; Shukla, Anil K.; Lester, Mark
1993-04-01
We have studied 37-MHz signals received over an 800-km temperate latitude path using 400-W continuous wave transmissions. Signals collected during a 9-day period in February 1990 on two antennas at separations of 5, 10, and 20 lambda were analyzed. Three signal categories were identified (overdense, underdense, and not known (NK)) and cross-correlation coefficients between the signals received by the two antennas were calculated for each signal category. No spatial variation, and in particular no decrease, in average cross-correlation coefficient was observed for underdense or NK signals as the antenna spacing was increased from 5 to 20 lambda. At each antenna separation the cross-correlation coefficients of these two categories were strongly dependent on time. Overdense signals, however, showed no cross-correlation time dependency at 5 and 10 lambda, but there was a strong time dependency at 20 lambda. Recommendations are made in regard to the optimum antenna spacing for a meteor burst communication system using spaced antenna diversity.
Using convolutional decoding to improve time delay and phase estimation in digital communications
Ormesher, Richard C [Albuquerque, NM; Mason, John J [Albuquerque, NM
2010-01-26
The time delay and/or phase of a communication signal received by a digital communication receiver can be estimated based on a convolutional decoding operation that the communication receiver performs on the received communication signal. If the original transmitted communication signal has been spread according to a spreading operation, a corresponding despreading operation can be integrated into the convolutional decoding operation.
Siedlecki, Cédric; Gauthé, Rémi; Gillibert, André; Bellenger, Kevin; Roussignol, Xavier; Ould-Slimane, Mourad
2017-10-01
The use of fluoroscopy is necessary during proximal femoral fracture (PFF) osteosynthesis. The frequency of these procedures justifies a description of radiation exposure and comparisons between different techniques and between the different surgical team members. This observational prospective and comparative study includes a series of 68 patients with PFF receiving osteosynthesis. Radiation exposure was assessed for all members of the operating team. The radiation dose measurements for the different members of the surgical team during PFF osteosynthesis were compared. The factors affecting the radiation dose were investigated. The mean active dosimeter readings for each operation were 7.39 µSv for the primary surgeon, 3.93 µSv for the assistant surgeon, 1.92 µSv for the instrument nurse, 1.25 µSv for the circulating nurse, and 0.64 µSv for the anaesthesiologist, respectively. Doses decreased significantly between these different members of the medical team (all p < 0.001). The dose also varied with patient age and BMI, as well as with fluoroscopy time and operating time, but not with type of fracture or type of osteosynthesis. Medical staff receives significantly different doses depending on their position in relation to the radiation source. Operating time and fluoroscopy time are the modifiable factors that affect the radiation dose. The radiation doses received by the different members of the medical teams involved in proximal femur osteosynthesis procedures all fall below the doses recommended by the International Commission on Radiation Units and Measurements.
Message Received How to Bridge the Communication Gap and Save Lives
2004-03-01
safety during an emergency depend on the ability of first responders to talk via radio, directly, without dispatch and in real time. Many technologies are...Words interoperability Coast Guard first responders procedures interagency communications policies 18...communication interoperability for public safety first responders entails far more than finding and emplacing a technology and training the operators. The
Effect of Detector Dead Time on the Performance of Optical Direct-Detection Communication Links
NASA Technical Reports Server (NTRS)
Chen, C.-C.
1988-01-01
Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detect ion sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulted (PPM) channel is studied by analyzing the error probability. It is shown that, when back- ground noise is negligible, the performance of the detector with dead time is similar to that o f a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on background intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.
Effect of detector dead time on the performance of optical direct-detection communication links
NASA Astrophysics Data System (ADS)
Chen, C.-C.
1988-05-01
Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.
Turbine sizing of a solar thermal power plant
NASA Technical Reports Server (NTRS)
Manvi, R.; Fujita, T.
1979-01-01
Since the insolation is intermittent, thermal energy storage is necessary to extend the time of power generation with solar heat past sunset. There are two approaches to specifying the size of turbine-generator units depending on the system operation. In the first approach, the turbine operates at its full capacity when operating on direct solar heat, and at reduced capacity when operating on collected heat out of energy storage. In the second approach, the turbine will always operate at a uniform level either on derated energy from the receiver or from energy storage. Both of these approaches have certain advantages and disadvantages. In this paper, a simple analysis is outlined and exercised to compare the performance and economics of these two approaches.
Experimental detection and focusing in shallow water by decomposition of the time reversal operator.
Prada, Claire; de Rosny, Julien; Clorennec, Dominique; Minonzio, Jean-Gabriel; Aubry, Alexandre; Fink, Mathias; Berniere, Lothar; Billand, Philippe; Hibral, Sidonie; Folegot, Thomas
2007-08-01
A rigid 24-element source-receiver array in the 10-15 kHz frequency band, connected to a programmable electronic system, was deployed in the Bay of Brest during spring 2005. In this 10- to 18-m-deep environment, backscattered data from submerged targets were recorded. Successful detection and focusing experiments in very shallow water using the decomposition of the time reversal operator (DORT method) are shown. The ability of the DORT method to separate the echo of a target from reverberation as well as the echo from two different targets at 250 m is shown. An example of active focusing within the waveguide using the first invariant of the time reversal operator is presented, showing the enhanced focusing capability. Furthermore, the localization of the scatterers in the water column is obtained using a range-dependent acoustic model.
Frehmann, T; Niemann, A; Ustohal, P; Geiger, W F
2002-01-01
Four individual mathematical submodels simulating different subsystems of urban drainage were intercoupled to an integral model. The submodels (for surface runoff, flow in sewer system, wastewater treatment plant and receiving water) were calibrated on the basis of field data measured in an existing urban catchment investigation. Three different strategies for controlling the discharge in the sewer network were defined and implemented in the integral model. The impact of these control measures was quantified by representative immission state-parameters of the receiving water. The results reveal that the effect of a control measure may be ambivalent, depending on the referred component of a complex drainage system. Furthermore, it is demonstrated that the drainage system in the catchment investigation can be considerably optimised towards environmental protection and operation efficiency if an appropriate real time control on the integral scale is applied.
Radiant energy receiver having improved coolant flow control means
Hinterberger, H.
1980-10-29
An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.
Findeisen, Peter; Thumfart, Jörg Oliver; Costina, Victor; Hofheinz, Ralf; Neumaier, Michael
2013-09-01
To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. This "proteomics degradation clock" can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.
Real-time validation of receiver state information in optical space-time block code systems.
Alamia, John; Kurzweg, Timothy
2014-06-15
Free space optical interconnect (FSOI) systems are a promising solution to interconnect bottlenecks in high-speed systems. To overcome some sources of diminished FSOI performance caused by close proximity of multiple optical channels, multiple-input multiple-output (MIMO) systems implementing encoding schemes such as space-time block coding (STBC) have been developed. These schemes utilize information pertaining to the optical channel to reconstruct transmitted data. The STBC system is dependent on accurate channel state information (CSI) for optimal system performance. As a result of dynamic changes in optical channels, a system in operation will need to have updated CSI. Therefore, validation of the CSI during operation is a necessary tool to ensure FSOI systems operate efficiently. In this Letter, we demonstrate a method of validating CSI, in real time, through the use of moving averages of the maximum likelihood decoder data, and its capacity to predict the bit error rate (BER) of the system.
Flight and ground tests of a GOES satellite time receiver for satellite communications applications
NASA Technical Reports Server (NTRS)
Swanson, R. L.; Nichols, S. A.
1981-01-01
A satellite time receiver was tested in various environmental conditions during the past year. The commercial receiver designed to work with the National Oceanic and Atmospheric Administration's (NOAA) Geostationary Operational Environmental Satellites (GOES). The test program included operation at low elevation during flight in a military cargo aircraft and long term comparison with laboratory standards. The GOES satellite time receiver offers an opportunity to provide easy wide area coverage synchronization at low cost.
1993-06-01
additional source. For the past three years VNIIFTRI (Mendeleevo, Moscow Region, Russian Federation) and some other Russian time laboratories have used...Russian-built GLONASS navigation receivers for time 47 comparisons. Since June 1991, VNIIFTRI has operated a commercial CPS time receiver on loan from...the BIPM. Since February 1992, the BIPM has operated Russian GLONASS receiver on loan from the VNIIFTRI . This provides, for the first time, an
Time-dependent classification accuracy curve under marker-dependent sampling.
Zhu, Zhaoyin; Wang, Xiaofei; Saha-Chaudhuri, Paramita; Kosinski, Andrzej S; George, Stephen L
2016-07-01
Evaluating the classification accuracy of a candidate biomarker signaling the onset of disease or disease status is essential for medical decision making. A good biomarker would accurately identify the patients who are likely to progress or die at a particular time in the future or who are in urgent need for active treatments. To assess the performance of a candidate biomarker, the receiver operating characteristic (ROC) curve and the area under the ROC curve (AUC) are commonly used. In many cases, the standard simple random sampling (SRS) design used for biomarker validation studies is costly and inefficient. In order to improve the efficiency and reduce the cost of biomarker validation, marker-dependent sampling (MDS) may be used. In a MDS design, the selection of patients to assess true survival time is dependent on the result of a biomarker assay. In this article, we introduce a nonparametric estimator for time-dependent AUC under a MDS design. The consistency and the asymptotic normality of the proposed estimator is established. Simulation shows the unbiasedness of the proposed estimator and a significant efficiency gain of the MDS design over the SRS design. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Müller, M C; Strauss, A; Pflugmacher, R; Nähle, C P; Pennekamp, P H; Burger, C; Wirtz, D C
2014-08-01
There is a positive correlation between operation time and staff exposure to radiation during intraoperative use of C-arm fluoroscopy. Due to harmful effects of exposure to long-term low-dose radiation for both the patient and the operating team it should be kept to a minimum. AIM of this study was to evaluate a novel dosimeter system called Dose Aware® (DA) enabling radiation exposure feedback of the personal in an orthopaedic and trauma operation theatre in real-time. Within a prospective study over a period of four month, DA was applied by the operation team during 104 orthopaedic and trauma operations in which the C-arm fluoroscope was used in 2D-mode. During ten operation techniques, radiation exposure of the surgeon, the first assistant, the theatre nurse and the anaesthesiologist was evaluated. Seventy-three operations were analysed. The surgeon achieved the highest radiation exposure during dorsolumbar spinal osteosynthesis, kyphoplasty and screw fixation of sacral fractures. The first assistant received a higher radiation exposure compared to the surgeon during plate osteosynthesis of distal radius fractures (157 %), intramedullary nailing of pertrochanteric fractures (143 %) and dorsolumbar spinal osteosynthesis (240 %). During external fixation of ankle fractures (68 %) and screw fixation of sacral fractures (66 %) radiation exposure of the theatre nurse exceeded 50 % of the surgeon's radiation exposure. During plate osteosynthesis of distal radius fractures (157 %) and intramedullary splinting of clavicular fractures (115 %), the anaesthesiologist received a higher radiation exposure than the surgeon. The novel dosimeter system DA provides real-time radiation exposure feedback of the personnel in an orthopaedic and trauma operation theatre for the first time. Data of this study demonstrate that radiation exposure of the personnel depends on the operation type. The first assistant, the theatre nurse and the anaesthesiologist might be exposed to higher radiation doses than the surgeon. DA might help to increase awareness concerning irradiation in an orthopaedic and trauma operation theatre and might enhance staff compliance in using radiation protection techniques. Georg Thieme Verlag KG Stuttgart · New York.
Time-dependent efficacy of longitudinal biomarker for clinical endpoint.
Kolamunnage-Dona, Ruwanthi; Williamson, Paula R
2018-06-01
Joint modelling of longitudinal biomarker and event-time processes has gained its popularity in recent years as they yield more accurate and precise estimates. Considering this modelling framework, a new methodology for evaluating the time-dependent efficacy of a longitudinal biomarker for clinical endpoint is proposed in this article. In particular, the proposed model assesses how well longitudinally repeated measurements of a biomarker over various time periods (0,t) distinguish between individuals who developed the disease by time t and individuals who remain disease-free beyond time t. The receiver operating characteristic curve is used to provide the corresponding efficacy summaries at various t based on the association between longitudinal biomarker trajectory and risk of clinical endpoint prior to each time point. The model also allows detecting the time period over which a biomarker should be monitored for its best discriminatory value. The proposed approach is evaluated through simulation and illustrated on the motivating dataset from a prospective observational study of biomarkers to diagnose the onset of sepsis.
Blocksome, Michael A [Rochester, MN
2011-12-20
Methods, apparatus, and products are disclosed for determining when a set of compute nodes participating in a barrier operation on a parallel computer are ready to exit the barrier operation that includes, for each compute node in the set: initializing a barrier counter with no counter underflow interrupt; configuring, upon entering the barrier operation, the barrier counter with a value in dependence upon a number of compute nodes in the set; broadcasting, by a DMA engine on the compute node to each of the other compute nodes upon entering the barrier operation, a barrier control packet; receiving, by the DMA engine from each of the other compute nodes, a barrier control packet; modifying, by the DMA engine, the value for the barrier counter in dependence upon each of the received barrier control packets; exiting the barrier operation if the value for the barrier counter matches the exit value.
Time reversal technique for gas leakage detection.
Maksimov, A O; Polovinka, Yu A
2015-04-01
The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise.
The c-index is not proper for the evaluation of $t$-year predicted risks.
Blanche, Paul; Kattan, Michael W; Gerds, Thomas A
2018-02-16
We show that the widely used concordance index for time to event outcome is not proper when interest is in predicting a $t$-year risk of an event, for example 10-year mortality. In the situation with a fixed prediction horizon, the concordance index can be higher for a misspecified model than for a correctly specified model. Impropriety happens because the concordance index assesses the order of the event times and not the order of the event status at the prediction horizon. The time-dependent area under the receiver operating characteristic curve does not have this problem and is proper in this context.
Automatic transponder. [measurement of the internal delay time of a transponder
NASA Technical Reports Server (NTRS)
Anderson, R. E.; Brisken, A. F.; Lewis, J. R. (Inventor)
1977-01-01
A method and apparatus for the automatic, remote measurement of the internal delay time of a transponder at the time of operation is provided. A small portion of the transmitted signal of the transponder is converted to the receive signal frequency of the transponder and supplied to the input of the transponder. The elapsed time between the receive signal locally generated and the receive signal causing the transmission of the transmitted signal is measured, said time being representative of or equal to the internal delay time of the transponder at the time of operation.
Health Monitoring Survey of Bell 412EP Transmissions
NASA Technical Reports Server (NTRS)
Tucker, Brian E.; Dempsey, Paula J.
2016-01-01
Health and usage monitoring systems (HUMS) use vibration-based Condition Indicators (CI) to assess the health of helicopter powertrain components. A fault is detected when a CI exceeds its threshold value. The effectiveness of fault detection can be judged on the basis of assessing the condition of actual components from fleet aircraft. The Bell 412 HUMS-equipped helicopter is chosen for such an evaluation. A sample of 20 aircraft included 12 aircraft with confirmed transmission and gearbox faults (detected by CIs) and eight aircraft with no known faults. The associated CI data is classified into "healthy" and "faulted" populations based on actual condition and these populations are compared against their CI thresholds to quantify the probability of false alarm and the probability of missed detection. Receiver Operator Characteristic analysis is used to optimize thresholds. Based on the results of the analysis, shortcomings in the classification method are identified for slow-moving CI trends. Recommendations for improving classification using time-dependent receiver-operator characteristic methods are put forth. Finally, lessons learned regarding OEM-operator communication are presented.
34 CFR 682.421 - Funds transferred from the Federal Fund to the Operating Fund by a guaranty agency.
Code of Federal Regulations, 2011 CFR
2011-07-01
... receiving the Secretary's approval, the agency may transfer the requested funds at any time within 6 months... request within 30 days after receiving it, the agency may transfer the requested funds at any time within... deposited into the agency's Operating Fund. The amount transferred and outstanding at any time during the...
34 CFR 682.421 - Funds transferred from the Federal Fund to the Operating Fund by a guaranty agency.
Code of Federal Regulations, 2013 CFR
2013-07-01
... receiving the Secretary's approval, the agency may transfer the requested funds at any time within 6 months... request within 30 days after receiving it, the agency may transfer the requested funds at any time within... deposited into the agency's Operating Fund. The amount transferred and outstanding at any time during the...
Wu, Cai; Li, Liang
2018-05-15
This paper focuses on quantifying and estimating the predictive accuracy of prognostic models for time-to-event outcomes with competing events. We consider the time-dependent discrimination and calibration metrics, including the receiver operating characteristics curve and the Brier score, in the context of competing risks. To address censoring, we propose a unified nonparametric estimation framework for both discrimination and calibration measures, by weighting the censored subjects with the conditional probability of the event of interest given the observed data. The proposed method can be extended to time-dependent predictive accuracy metrics constructed from a general class of loss functions. We apply the methodology to a data set from the African American Study of Kidney Disease and Hypertension to evaluate the predictive accuracy of a prognostic risk score in predicting end-stage renal disease, accounting for the competing risk of pre-end-stage renal disease death, and evaluate its numerical performance in extensive simulation studies. Copyright © 2018 John Wiley & Sons, Ltd.
Comparison of GPS and GLONASS Common-View Time Transfers
1992-12-01
interest as an excellent additional source. For the past three years VNIIFTRI (Mendeleevo, Moscow Region, Russian Federation) and some other Russian time...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 comparisons. Since June 1991, VNIIFTRI has operated a commercial GPS time receiver on...loan from the BIPM. Since February 1992, the BIPM has operated Russian GLONASS receiver on loan from the VNIIFTRI . Thii provides, for the first time
Risk is not our business: safety of thoracic surgery in patients using antiplatelet therapy.
Bertolaccini, Luca; Terzi, Alberto; Rizzardi, Giovanna; Gorla, Alberto; Viti, Andrea; Palmisano, Sarah; Coletta, Giuseppe
2012-02-01
American Heart Association recommendations have changed preoperative management of patients with antiplatelet therapy (APT). We assessed safety and outcomes of surgery in patients who were receiving APT. A prospective study of patients operated on while receiving APT was matched with those with no APT (ratio 1:4), using the propensity score method. Logistic regression analysis was used to identify covariates among imbalanced baseline patient variables. Both χ(2) test and Fisher's test were used to calculate the probability value for the comparison of dichotomous variables. Between January 2008 and December 2010, 38 patients who received APT at the time of surgery were matched with 141 patients who had not received APT. APT indications were a history of myocardial infarction, coronary artery by-pass graft and/or valve replacement (19), coronary artery stent (11) and severe peripheral vascular disease (8). None of the patients required re-operation for bleeding. Two patients received blood transfusions. The amount of chest tube drainage was not statistically significantly different. There were no statistically significant differences between the outcomes for the operative time, length of hospital stay, estimated blood loss or morbidity. The results show that thoracic surgical procedures can safely be performed in patients receiving APT at the time of surgery, with no increased risk of bleeding or morbidity and no differences in the operative time and the length of hospital stay.
Maktabi, Marianne; Neumuth, Thomas
2017-12-22
The complexity of surgical interventions and the number of technologies involved are constantly rising. Hospital staff has to learn how to handle new medical devices efficiently. However, if medical device-related incidents occur, the patient treatment is delayed. Patient safety could therefore be supported by an optimized assistance system that helps improve the management of technical equipment by nonmedical hospital staff. We developed a system for the optimal monitoring of networked medical device activity and maintenance requirements, which works in conjunction with a vendor-independent integrated operating room and an accurate surgical intervention Time And Resource Management System. An integrated situation-dependent risk assessment system gives the medical engineers optimal awareness of the medical devices in the operating room. A qualitative and quantitative survey among ten medical engineers from three different hospitals was performed to evaluate the approach. A series of 25 questions was used to evaluate various aspects of our system as well as the system currently used. Moreover, the respondents were asked to perform five tasks related to system supervision and incident handling. Our system received a very positive feedback. The evaluation studies showed that the integration of information, the structured presentation of information, and the assistance modules provide valuable support to medical engineers. An automated operating room monitoring system with an integrated risk assessment and Time And Resource Management System module is a new way to assist the staff being outside of a vendor-independent integrated operating room, who are nevertheless involved in processes in the operating room.
Ropivacaine for unilateral spinal anesthesia; hyperbaric or hypobaric?
Cantürk, Mehmet; Kılcı, Oya; Ornek, Dilşen; Ozdogan, Levent; Pala, Yasar; Sen, Ozlem; Dikmen, Bayazit
2012-01-01
The aim of this study was to compare the unilaterality of subarachnoid block achieved with hyperbaric and hypobaric ropivacaine. The prospective, randomized trial was conducted in an orthopedics surgical suite. In all, 60 ASA I-III patients scheduled for elective total knee arthroplasty were included in the study. Group Hypo (n=30) received 11.25mg of ropivacaine (7.5mg.mL(-1)) + 2mL of distilled water (density at room temperature was 0.997) and group Hyper (n=30) received 11.25mg of ropivacaine (7.5mg.mL(-1)) + 2mL (5mg.mL(-1)) of dextrose (density at room temperature was 1,015). Patients in the hyperbaric group were positioned with the operated side down and in the 15° Fowler position, versus those in the hypobaric group with the operated side facing up and in the 15° Trendelenburg position. Combined spinal epidural anesthesia was performed midline at the L(3-4) lumbar interspace. Hemodynamic and spinal block parameters, regression time, success of unilateral spinal anesthesia, patient comfort, surgical comfort, surgeon comfort, first analgesic requirement time, and adverse effects were assessed. Time to reach the T10 dermatome level on the operated side was shorter in group Hyper (612.00±163.29s) than in group Hypo (763.63±208.35s) (p<0.05). Time to 2-segment regression of the sensory block level on both the operated and non-operated sides was shorter in group Hypo than in group Hyper. Both hyperbaric and hypobaric ropivacaine (11.25mg) provided adequate and dependable anesthesia for total knee replacement surgery, with a high level of patient and surgeon comfort. Hypobaric local anesthetic solutions provide a high level of unilateral anesthesia, with rapid recovery of both sensory and motor block, and therefore may be preferable in outpatient settings. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.
Wavelet and receiver operating characteristic analysis of heart rate variability
NASA Astrophysics Data System (ADS)
McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.
2002-02-01
Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.
NASA Astrophysics Data System (ADS)
Thongtan, Thayathip; Tirawanichakul, Pawit; Satirapod, Chalermchon
2017-12-01
Each GNSS constellation operates its own system times; namely, GPS system time (GPST), GLONASS system time (GLONASST), BeiDou system time (BDT) and Galileo system time (GST). They could be traced back to Coordinated Universal Time (UTC) scale and are aligned to GPST. This paper estimates the receiver clock offsets to three timescales: GPST, GLONASST and BDT. The two measurement scenarios use two identical multi-GNSS geodetic receivers connected to the same geodetic antenna through a splitter. One receiver is driven by its internal oscillators and another receiver is connected to the external frequency oscillators, caesium frequency standard, kept as the Thailand standard time scale at the National Institute of Metrology (Thailand) called UTC(NIMT). The three weeks data are observed at 30 seconds sample rate. The receiver clock offsets with respected to the three system time are estimated and analysed through the geodetic technique of static Precise Point Positioning (PPP) using a data processing software developed by Wuhan University - Positioning And Navigation Data Analyst (PANDA) software. The estimated receiver clock offsets are around 32, 33 and 18 nanoseconds from GPST, GLONASST and BDT respectively. This experiment is initially stated that each timescale is inter-operated with GPST and further measurements on receiver internal delay has to be determined for clock comparisons especially the high accuracy clock at timing laboratories.
Ito, Hiroaki; Iida, Mitsuo; Matsumoto, Takayuki; Suzuki, Yasuo; Aida, Yoshiyuki; Yoshida, Toyomitsu; Takano, Yuichi; Hibi, Toshifumi
2010-09-01
Mesalamine has been used as the first-line medication for the treatment of ulcerative colitis (UC). We directly compared the efficacy and safety of two different mesalamine formulations in the maintenance of remission in patients with UC. In a multicenter, double-blind, randomized study, 131 patients with quiescent UC were assigned to two groups: 65 to receive a pH-dependent release formulation of mesalamine at 2.4 g/day (pH-2.4 g) and 66 to receive a time-dependent release formulation of mesalamine at 2.25 g/day (Time-2.25 g). Both formulations were administered three times daily for 48 weeks. The primary endpoint was the proportion of patients without bloody stools. In the full analysis set (n = 130), the proportion of patients without bloody stools was 76.9% in the pH-2.4 g and 69.2% in the Time-2.25 g, demonstrating the noninferiority of pH-2.4 g to Time-2.25 g. No statistically significant difference in time to bloody stools was found between the two formulations (P = 0.27, log-rank test), but the time to bloody stools tended to be longer in pH-2.4 g compared to Time-2.25 g, and a similar trend was observed with regard to the time to relapse. No differences were observed between the safety profiles of the two formulations. The pH- and time-dependent release of mesalamine formulations were similarly safe and effective. Interestingly, the remission phase tended to be longer in the group that received the pH-dependent formulation compared to the group that received the time-dependent formulation (UMIN Clinical Trials Registry, no. C000000289).
Reducing power consumption while performing collective operations on a plurality of compute nodes
Archer, Charles J [Rochester, MN; Blocksome, Michael A [Rochester, MN; Peters, Amanda E [Rochester, MN; Ratterman, Joseph D [Rochester, MN; Smith, Brian E [Rochester, MN
2011-10-18
Methods, apparatus, and products are disclosed for reducing power consumption while performing collective operations on a plurality of compute nodes that include: receiving, by each compute node, instructions to perform a type of collective operation; selecting, by each compute node from a plurality of collective operations for the collective operation type, a particular collective operation in dependence upon power consumption characteristics for each of the plurality of collective operations; and executing, by each compute node, the selected collective operation.
Evaluating Pseudorange Multipath at CGPS Stations Spanning Mexico
NASA Astrophysics Data System (ADS)
Vazquez, G.; Bennett, R. A.; Spinler, J. C.
2013-12-01
A research study was conducted in order to quantify and analyze the amount of pseudorange multipath at continuous Global Positioning System (CGPS) stations spanning Mexico. These CGPS stations are administered by a variety of organizations, including government agencies and public universities, and thus serve a wide range of positioning needs. Despite the diversity of the networks and their intended audiences, a core function of all of the networks is to provide a stable framework for high-precision positioning in support of diverse commercial and scientific applications. CGPS data from a large number of publicly available networks located in Mexico were studied. These include the RGNA (National Active Geodetic Network) administered by INEGI (National Institute of Statistics and Geography), the PBO network (Plate Boundary Observatory) funded by the National Science Foundation (NSF) and operated by UNAVCO (University NAVstar Consortium), the Southern California Integrated GPS Network (SCIGN), which is a collaboration effort of the United States Geological Survey (USGS), Scripps Institution of Oceanography and the Jet Propulsion Laboratory (JPL), the UNAM network, operated by the National Seismological System (SSN) and the Institute of Geophysics of the National Autonomous University of Mexico (UNAM), the Suominet Geodetic Network (SNG) and the CORS (Continuously Operating Reference Station) network, operated by the Federal Aviation Administration (FAA). A total of 54 CGPS stations were evaluated, where dual-frequency geodetic-grade receivers collected GPS data continuously during the period from 1994 to 2013. It is usually assumed that despite carefully selected locations, all CGPS stations are to some extent, affected by the presence of signal multipath. In addition, the geographic distribution of stations provides a nation-wide access to the International Terrestrial Reference Frame (ITRF). For real-time kinematic (RTK) and rapid static applications that depend on the pseudo-range observable, the accuracy with which a roaming user may locate their assets with respect to the ITRF may be limited by site-specific multipath. The issue is particularly critical for users depending on pseudorange measurements for 'real-time' (or 'near-real-time') kinematic GPS positioning, where ambiguity resolution is a critical step. Therefore, to identify the most and the least affected GPS stations we analyzed the averaged daily root mean square pseudorange multipath variations (MP1-RMS and MP2-RMS) for all feasible satellites tracked by the CGPS networks. We investigated the sources of multipath, including changes associated with hardware replacement (i.e., receiver and antenna type) and receiver firmware upgrades.
Changes in Brain Metabolite Concentrations after Neonatal Hypoxic-ischemic Encephalopathy.
Shibasaki, Jun; Aida, Noriko; Morisaki, Naho; Tomiyasu, Moyoko; Nishi, Yuri; Toyoshima, Katsuaki
2018-06-12
Purpose To investigate the time-course changes and predictive utility of brain metabolite concentrations in neonatal hypoxic-ischemic encephalopathy (HIE). Materials and Methods Sixty-eight neonates (age, 35-41 gestational weeks) with HIE were admitted to a neonatal intensive care unit between September 2009 and March 2016 and examined by using proton MR spectroscopy at 18-96 hours (n = 25) and 7-14 days (n = 64) after birth (35-43 postmenstrual weeks) to estimate metabolite concentrations in the deep gray matter. Adverse outcome was defined as death or neurodevelopmental impairment at 18-22 months of age. Areas under the receiver operating characteristic curves were calculated to evaluate the prognostic values of metabolites. Results At 18-96 hours, N-acetylaspartate and creatine concentrations were lower, whereas lactate, and glutamate and glutamine (Glx) concentrations were higher in neonates with adverse outcomes than in those with favorable outcomes. Metabolite concentrations at 18-96 hours decreased during days 7-14 in neonates with adverse outcomes but did not change in those with favorable outcomes. For N-acetylaspartate, creatine, lactate, and Glx concentrations measured at 18-96 hours to predict adverse outcomes, areas under the receiver operating characteristic curve were 0.98, 0.89, 0.96, and 0.88, respectively, whereas at 7-14 days, the areas under the receiver operating characteristic curve were 0.97, 0.97, 0.59, and 0.36, respectively. Conclusion Time-dependent reductions in N-acetylaspartate and creatine concentrations at both 18-96 hours and 7-14 days accurately predicted adverse outcomes. However, higher lactate and glutamate and glutamine concentrations were often transient. © RSNA, 2018 Online supplemental material is available for this article.
X-Band Acquisition Aid Software
NASA Technical Reports Server (NTRS)
Britcliffe, Michael J.; Strain, Martha M.; Wert, Michael
2011-01-01
The X-band Acquisition Aid (AAP) software is a low-cost acquisition aid for the Deep Space Network (DSN) antennas, and is used while acquiring a spacecraft shortly after it has launched. When enabled, the acquisition aid provides corrections to the antenna-predicted trajectory of the spacecraft to compensate for the variations that occur during the actual launch. The AAP software also provides the corrections to the antenna-predicted trajectory to the navigation team that uses the corrections to refine their model of the spacecraft in order to produce improved antenna-predicted trajectories for each spacecraft that passes over each complex. The software provides an automated Acquisition Aid receiver calibration, and provides graphical displays to the operator and remote viewers via an Ethernet connection. It has a Web server, and the remote workstations use the Firefox browser to view the displays. At any given time, only one operator can control any particular display in order to avoid conflicting commands from more than one control point. The configuration and control is accomplished solely via the graphical displays. The operator does not have to remember any commands. Only a few configuration parameters need to be changed, and can be saved to the appropriate spacecraft-dependent configuration file on the AAP s hard disk. AAP automates the calibration sequence by first commanding the antenna to the correct position, starting the receiver calibration sequence, and then providing the operator with the option of accepting or rejecting the new calibration parameters. If accepted, the new parameters are stored in the appropriate spacecraft-dependent configuration file. The calibration can be performed on the Sun, greatly expanding the window of opportunity for calibration. The spacecraft traditionally used for calibration is in view typically twice per day, and only for about ten minutes each pass.
Single neuron firing properties impact correlation-based population coding
Hong, Sungho; Ratté, Stéphanie; Prescott, Steven A.; De Schutter, Erik
2012-01-01
Correlated spiking has been widely observed but its impact on neural coding remains controversial. Correlation arising from co-modulation of rates across neurons has been shown to vary with the firing rates of individual neurons. This translates into rate and correlation being equivalently tuned to the stimulus; under those conditions, correlated spiking does not provide information beyond that already available from individual neuron firing rates. Such correlations are irrelevant and can reduce coding efficiency by introducing redundancy. Using simulations and experiments in rat hippocampal neurons, we show here that pairs of neurons receiving correlated input also exhibit correlations arising from precise spike-time synchronization. Contrary to rate co-modulation, spike-time synchronization is unaffected by firing rate, thus enabling synchrony- and rate-based coding to operate independently. The type of output correlation depends on whether intrinsic neuron properties promote integration or coincidence detection: “ideal” integrators (with spike generation sensitive to stimulus mean) exhibit rate co-modulation whereas “ideal” coincidence detectors (with spike generation sensitive to stimulus variance) exhibit precise spike-time synchronization. Pyramidal neurons are sensitive to both stimulus mean and variance, and thus exhibit both types of output correlation proportioned according to which operating mode is dominant. Our results explain how different types of correlations arise based on how individual neurons generate spikes, and why spike-time synchronization and rate co-modulation can encode different stimulus properties. Our results also highlight the importance of neuronal properties for population-level coding insofar as neural networks can employ different coding schemes depending on the dominant operating mode of their constituent neurons. PMID:22279226
78 FR 45287 - Petition for Exemption; Summary of Petition Received
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... CFR Sec. 91.225(a), (b), and (d), Automatic Dependent Surveillance-Broadcast (ADS-B) Out, on all... Extended Squitter (ES) ADS-B and Traffic information Service-Broadcast (TIS-B) operating on the frequency of 1090 Megahertz (MHz) and Universal Access Transceiver (UAT) ADS-B equipment operating on the...
Driver detention times in commercial motor vehicle operations : [research brief].
DOT National Transportation Integrated Search
2014-12-01
The purpose of this project was to better understand : the nature of detention times in the commercial motor : vehicle (CMV) industry. Detention time refers to the : time that CMV operators may experience at shipping : and receiving facilities associ...
Ho, Lavine; White, Peter; Chan, Edward; Chan, Kim; Ng, Janet; Tam, Timothy
2012-01-01
Linear accelerators operating at or above 10 MV produce neutrons by photonuclear reactions and induce activation in machine components, which are a source of potential exposure for radiation therapists. This study estimated gamma dose contributions to radiation therapists during high energy, whole pelvic, photon beam treatments and determined the optimum room entry times, in terms of safety of radiation therapists. Two types of technique (anterior-posterior opposing and 3-field technique) were studied. An Elekta Precise treatment system, operating up to 18 MV, was investigated. Measurements with an area monitoring device (a Mini 900R radiation monitor) were performed, to calculate gamma dose rates around the radiotherapy facility. Measurements inside the treatment room were performed when the linear accelerator was in use. The doses received by radiation therapists were estimated, and optimum room entry times were determined. The highest gamma dose rates were approximately 7 μSv/h inside the treatment room, while the doses in the control room were close to background (~0 μSv/h) for all techniques. The highest personal dose received by radiation therapists was estimated at 5 mSv/yr. To optimize protection, radiation therapists should wait for up to11 min after beam-off prior to room entry. The potential risks to radiation therapists with standard safety procedures were well below internationally recommended values, but risks could be further decreased by delaying room entry times. Dependent on the technique used, optimum entry times ranged between 7 to 11 min. A balance between moderate treatment times versus reduction in measured equivalent doses should be considered.
Navy Operational Planner: Anti-Submarine Warfare with Time-Dependent Performance
2017-09-01
PLANNER: ANTI-SUBMARINE WARFARE WITH TIME -DEPENDENT PERFORMANCE by Anthony M. Baldessari September 2017 Thesis Advisor: W. Matthew...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instruction, searching...REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE NAVY OPERATIONAL PLANNER: ANTI-SUBMARINE WARFARE WITH TIME -DEPENDENT
NASA Technical Reports Server (NTRS)
Xiao, Yegao; Bhat, Ishwara; Abedin, M. Nurul
2005-01-01
InP/InGaAs avalanche photodiodes (APDs) are being widely utilized in optical receivers for modern long haul and high bit-rate optical fiber communication systems. The separate absorption, grading, charge, and multiplication (SAGCM) structure is an important design consideration for APDs with high performance characteristics. Time domain modeling techniques have been previously developed to provide better understanding and optimize design issues by saving time and cost for the APD research and development. In this work, performance dependences on multiplication layer thickness have been investigated by time domain modeling. These performance characteristics include breakdown field and breakdown voltage, multiplication gain, excess noise factor, frequency response and bandwidth etc. The simulations are performed versus various multiplication layer thicknesses with certain fixed values for the areal charge sheet density whereas the values for the other structure and material parameters are kept unchanged. The frequency response is obtained from the impulse response by fast Fourier transformation. The modeling results are presented and discussed, and design considerations, especially for high speed operation at 10 Gbit/s, are further analyzed.
Imaging and modeling new VETEM data
Wright, David L.; Smith, David V.; Abraham, Jared D.; Hutton, Raymond S.; Bond, E. Kent; Cui, Tie Jun; Aydiner, Alaeddin A.; Chew, Weng Cho
2000-01-01
In previously reported work (Wright and others, 2000) we found that the very early time electromagnetic (VETEM) prototype system produced data from which high resolution images of a buried former foundry site at the Denver Federal Center were made. The soil covering the site is about 30 mS/m conductivity, and is thus relatively unfavorable for ground penetrating radar (GPR) imaging. We have surveyed portions of this site again with new electric field dipole antennas and a new receiver designed for these antennas. Comparisons of the images produced using the loop antennas to those produced using the electric field dipole antennas illustrate that for this application the loop antennas produced more useful images. The larger man-made structures can be seen more clearly because they are not masked by dispersion and/or smaller scale variations as with the electric field dipole antennas. The VETEM system now contains an array of antennas with appropriate transmitters and receivers and can be operated as a low frequency time domain GPR or as a high frequency time domain electromagnetic (EM) system with several possible antenna spacings and polarizations. We plan to examine additional configurations. Numerical modeling of the perpendicular loop antenna configuration has been done and depth estimates produced. We conclude that, as with other GPR and time domain EM systems, the best choice of operating parameters depends on the application and the environment, but the inherent flexibility of the VETEM system allows a wide range of options.
NASA Astrophysics Data System (ADS)
Sechin, A.; Kyrmakova, O.; Osipenko, S.
2016-01-01
In this article the research directed on development of a technique of definition of time of induction of the self-ignition of substances and materials which is an indicator of the beginning of development of an emergency is conducted. The experiment consisting in supervision over process of self-ignition of coal and oil deposits was the basis for research. On the basis of experimental data the curve expressing analytic - expected dependence of size of temperature of ignition on induction time was constructed. Proceeding from graphical representation of process, functional dependence of time of induction on a temperature indicator was received: y = 16920 • x0 537. By means of known indicators of such substances as bitumen oil oxidized (the combustible solid substance received by oxidation of residual product of oil refining) and tar oil (the combustible solid substance which is residual product of oil refining) and the received algorithm, verification of reliability of the received dependence and a technique of definition of time of induction of spontaneous ignition of deposits of oil in general was carried out. The practical importance of the conducted research is that having data on time of induction of process of self-ignition, by means of preventive measures becomes possible to avoid and prevent accidents in oil and oil processing branches, at the same time loss of property and loss of human life.
Improvement of Hungarian Joint Terminal Attack Program
2013-06-13
LST Laser Spot Tracker NVG Night Vision Goggle ROMAD Radio Operator Maintainer and Driver ROVER Remotely Operated Video Enhanced Receiver TACP...visual target designation. The other component consists of a laser spot tracker (LST), which identifies targets by tracking laser energy reflecting...capability for every type of night time missions, laser spot tracker for laser spot search missions, remotely operated video enhanced receiver
Wiedemann, Dominik; Bonaros, Nikolaos; Schachner, Thomas; Weidinger, Felix; Lehr, Eric J; Vesely, Mark; Bonatti, Johannes
2012-03-01
Robotically assisted totally endoscopic coronary artery bypass grafting (TECAB) is a viable option for closed chest coronary surgery, but it requires learning curves and longer operative times. This study evaluated the effect of extended operation times on the outcome of patients undergoing TECAB. From 2001 to 2009, 325 patients underwent TECAB with the da Vinci telemanipulation system. Correlations between operative times and preoperative, intraoperative, and early postoperative parameters were investigated. Receiver operating characteristic analysis was used to define the threshold of the procedure duration above which intensive care unit stay and ventilation time were prolonged. Demographic data, intraoperative and postoperative parameters, and survival data were compared. Patients with prolonged operative times more often underwent multivessel revascularization (P < .001) and beating-heart TECAB (P =.023). Other preoperative parameters were not associated with longer operative times. Incidences of technical difficulties and conversions (P < .001) were higher among patients with longer operative times. Prolonged intensive care unit stay, mechanical ventilation, hospital stay, and with requirement of blood products were associated with longer operative times. Receiver operating characteristic analysis showed operative times >445 minutes and >478 minutes to predict prolonged (>48 hours) intensive care unit stay and mechanical ventilation, respectively. Patients with procedures >478 minutes had longer hospital stays and higher perioperative morbidity and mortality. Kaplan-Meier analysis revealed decreased survival among patients with operative times >478 minutes. Multivessel revascularization and conversions lead to prolonged operative times in totally endoscopic coronary artery bypass grafting. Longer operative times significantly influence early postoperative and midterm outcomes. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Piessevaux, Hubert; Buyse, Marc; Schlichting, Michael; Van Cutsem, Eric; Bokemeyer, Carsten; Heeger, Steffen; Tejpar, Sabine
2013-10-20
Early tumor shrinkage (ETS) is associated with long-term outcome in patients with chemorefractory metastatic colorectal cancer (mCRC) receiving cetuximab. This association was investigated in the first-line setting in the randomized CRYSTAL and OPUS mCRC trials, after controlling for KRAS tumor mutation status. Radiologic assessments at week 8 were used to calculate the relative change in the sum of the longest diameters of the target lesions. Time-dependent receiver operating characteristics provided Cτ-indices (time-dependent c-index). Cox regression models and subpopulation treatment effect pattern plot analysis investigated associations between ETS (radiologic tumor size decrease at week 8) and survival and progression-free survival (PFS). In both trials, in patients with KRAS wild-type mCRC, Cτ values for PFS and survival were higher (P < .001) in those receiving chemotherapy plus cetuximab versus chemotherapy alone, indicating a stronger predictive value of ETS for long-term outcome in these patients. In the CRYSTAL and OPUS trials, respectively, the cutoff value of ETS ≥ 20% (v < 20%) identified patients with KRAS wild-type mCRC receiving chemotherapy plus cetuximab with longer PFS (medians 14.1 v 7.3 months, hazard ratio [HR] = 0.32; P < .001, and medians 11.9 v 5.7 months, HR = 0.22; P < .001) and survival (medians 30.0 v 18.6 months, HR = 0.53; P < .001 and medians 26.0 v 15.7 months, HR = 0.43; P = .006). ETS was significantly associated with long-term outcome in patients with KRAS wild-type mCRC treated first-line with chemotherapy plus cetuximab. Validation in prospective trials is required to assess the value of this on-treatment marker in the clinical decision-making process.
Ibuprofen timing for hand surgery in ambulatory care
Giuliani, Enrico; Bianchi, Anna; Marcuzzi, Augusto; Landi, Antonio; Barbieri, Alberto
2015-01-01
OBJECTIVE: To evaluate the effect of pre-operative administration of ibuprofen on post-operative pain control vs. early post-operative administration for hand surgery procedures performed under local anaesthesia in ambulatory care. METHODS: Candidates to trigger finger release by De Quervain tenosynovitis and carpal tunnel operation under local anesthesia were enrolled in the study. Group A received 400 mg ibuprofen before the operation and placebo after the procedure; group B received placebo before the operation and ibuprofen 400 mg at the end of the procedure; both groups received ibuprofen 400 mg every 6h thereafter. Visual analogue scale (VAS) was measured at fixed times before and every 6h after surgery, for a total follow-up of 18h. RESULTS: Groups were similar according to age, gender and type of surgery. Median VAS values did not produce any statistical significance, while there was a statistically significant difference on pre-operative and early post-operative VAS values between groups (A -8.53 mm vs. B 3.36 mm, p=0.0085). CONCLUSION: Average pain levels were well controlled by local anesthesia and post-operative ibuprofen analgesia. Pre-operative ibuprofen administration can contribute to improve early pain management. Level of Evidence II, Therapeutic Studies. PMID:26327799
Methodologies for reducing truck turn time at marine container terminals.
DOT National Transportation Integrated Search
2005-05-01
One of the prominent issues container terminal operators in the US are seeking to address is how to effectively : reduce truck turn time. Historically, truck turn time has received very little attention from terminal operators because port : congesti...
Randomized open-label trial of baclofen for relapse prevention in alcohol dependence.
Gupta, Manushree; Verma, Pankaj; Rastogi, Rajesh; Arora, Sheetal; Elwadhi, Deeksha
2017-05-01
Alcohol dependence is a progressive chronic disorder characterized by narrowing of the drinking repertoire, salience of drinking, tolerance and withdrawal phenomenon, compulsion to drink, and frequent relapses. Baclofen has been shown to promote abstinence, to reduce craving, and to reduce anxiety in alcohol-dependent individuals, and it promises to be a useful agent, although clinical data are limited at present. The current study aimed to test the utility of baclofen, a GABA agonist, in improving the relapse rates in alcohol-dependent subjects. A total of 122 alcohol-dependent subjects were randomized into two groups. Groups were administered baclofen (30 mg/day) or benfothiamine (a nutritional supplement) using an open label design. Both groups received brief motivational intervention. Subjects were assessed at 0, 2, 4, 8, and 12 weeks for the primary outcome measures: time to first relapse, heavy drinking days, cumulative abstinence duration, and craving (measured by the Obsessive Compulsive Drinking Scale (OCDS)). Seventy-two participants received baclofen, and 50 received benfothiamine. Participants receiving baclofen remained abstinent for significantly more days than the benfothiamine group (p < 0.05). The percentage of heavy drinking days was significantly lower in the baclofen group (p = 0.001). Craving and anxiety scores (Hamilton Anxiety Rating Scale) were also significantly decreased in the baclofen group relative to the control group (p = 0.001). Time to first relapse was similar in both groups. In this open-label trial, alcohol-dependent participants receiving baclofen showed significant improvements in drinking outcomes compared with participants receiving benfothiamine. This study provides further evidence that baclofen is useful for the treatment of alcohol dependence.
Ito, Hiroaki; Iida, Mitsuo; Matsumoto, Takayuki; Suzuki, Yasuo; Aida, Yoshiyuki; Yoshida, Toyomitsu; Takano, Yuichi; Hibi, Toshifumi
2010-01-01
Background: Mesalamine has been used as the first-line medication for the treatment of ulcerative colitis (UC). We directly compared the efficacy and safety of two different mesalamine formulations in the maintenance of remission in patients with UC. Methods: In a multicenter, double-blind, randomized study, 131 patients with quiescent UC were assigned to two groups: 65 to receive a pH-dependent release formulation of mesalamine at 2.4 g/day (pH-2.4 g) and 66 to receive a time-dependent release formulation of mesalamine at 2.25 g/day (Time-2.25 g). Both formulations were administered three times daily for 48 weeks. The primary endpoint was the proportion of patients without bloody stools. Results: In the full analysis set (n = 130), the proportion of patients without bloody stools was 76.9% in the pH-2.4 g and 69.2% in the Time-2.25 g, demonstrating the noninferiority of pH-2.4 g to Time-2.25 g. No statistically significant difference in time to bloody stools was found between the two formulations (P = 0.27, log-rank test), but the time to bloody stools tended to be longer in pH-2.4 g compared to Time-2.25 g, and a similar trend was observed with regard to the time to relapse. No differences were observed between the safety profiles of the two formulations. Conclusions: The pH- and time-dependent release of mesalamine formulations were similarly safe and effective. Interestingly, the remission phase tended to be longer in the group that received the pH-dependent formulation compared to the group that received the time-dependent formulation (UMIN Clinical Trials Registry, no. C000000289). (Inflamm Bowel Dis 2010) PMID:20049949
NASA Astrophysics Data System (ADS)
Hakoda, Christopher; Ren, Baiyang; Lissenden, Cliff J.; Rose, Joseph L.
2017-02-01
Thin-film PVDF (polyvinylidene fluoride) transducers are appealing as low cost, light weight, durable, and flexible sensors for structural health monitoring applications in aircraft structures. However, due to the relatively low Curie temperature of PVDF, there is a concern that it's performance will drop below acceptable levels during elevated-temperature operating conditions. To verify acceptable performance in these environmental operating conditions, temperature history data were collected between 23-60 °C. The effect of temperature on the thin-film PVDF was investigated and a temperature-independent damage feature was assessed. The temperature dependence of the signal's peak amplitude was investigated in both the time domain and the spectral domain to get two damage features. It was found that the measurement of the incident guided wave by the thin-film PVDF transducer had a temperature dependence that varied with frequency. A third damage feature, the mode ratio, was also calculated in the spectral domain with the goal of defining a damage feature that is temperature independent. A comparison of how well these damage features performed when used to identify a notch in an aluminum plate was made using receiver operating characteristic curves and their respective area under the curve values. This result demonstrated that a temperature-independent damage feature can be calculated, to some degree, by using a mode ratio between two modes of similar temperature dependence.
Calabria, Bianca; Clifford, Anton; Shakeshaft, Anthony P; Conigrave, Katherine M; Simpson, Lynette; Bliss, Donna; Allan, Julaine
2014-09-01
The Alcohol Use Disorders Identification Test (AUDIT) is a 10-item alcohol screener that has been recommended for use in Aboriginal primary health care settings. The time it takes respondents to complete AUDIT, however, has proven to be a barrier to its routine delivery. Two shorter versions, AUDIT-C and AUDIT-3, have been used as screening instruments in primary health care. This paper aims to identify the AUDIT-C and AUDIT-3 cutoff scores that most closely identify individuals classified as being at-risk drinkers, high-risk drinkers, or likely alcohol dependent by the 10-item AUDIT. Two cross-sectional surveys were conducted from June 2009 to May 2010 and from July 2010 to June 2011. Aboriginal Australian participants (N = 156) were recruited through an Aboriginal Community Controlled Health Service, and a community-based drug and alcohol treatment agency in rural New South Wales (NSW), and through community-based Aboriginal groups in Sydney NSW. Sensitivity, specificity, and positive and negative predictive values of each score on the AUDIT-C and AUDIT-3 were calculated, relative to cutoff scores on the 10-item AUDIT for at-risk, high-risk, and likely dependent drinkers. Receiver operating characteristic (ROC) curve analyses were conducted to measure the detection characteristics of AUDIT-C and AUDIT-3 for the three categories of risk. The areas under the receiver operating characteristic (AUROC) curves were high for drinkers classified as being at-risk, high-risk, and likely dependent. Recommended cutoff scores for Aboriginal Australians are as follows: at-risk drinkers AUDIT-C ≥ 5, AUDIT-3 ≥ 1; high-risk drinkers AUDIT-C ≥ 6, AUDIT-3 ≥ 2; and likely dependent drinkers AUDIT-C ≥ 9, AUDIT-3 ≥ 3. Adequate sensitivity and specificity were achieved for recommended cutoff scores. AUROC curves were above 0.90.
System and method for bearing fault detection using stator current noise cancellation
Zhou, Wei; Lu, Bin; Habetler, Thomas G.; Harley, Ronald G.; Theisen, Peter J.
2010-08-17
A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to repeatedly receive real-time operating current data from the operating motor and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.
Power inverter implementing phase skipping control
Somani, Utsav; Amirahmadi, Ahmadreza; Jourdan, Charles; Batarseh, Issa
2016-10-18
A power inverter includes a DC/AC inverter having first, second and third phase circuitry coupled to receive power from a power source. A controller is coupled to a driver for each of the first, second and third phase circuitry (control input drivers). The controller includes an associated memory storing a phase skipping control algorithm, wherein the controller is coupled to receive updating information including a power level generated by the power source. The drivers are coupled to control inputs of the first, second and third phase circuitry, where the drivers are configured for receiving phase skipping control signals from the controller and outputting mode selection signals configured to dynamically select an operating mode for the DC/AC inverter from a Normal Control operation and a Phase Skipping Control operation which have different power injection patterns through the first, second and third phase circuitry depending upon the power level.
NASA Technical Reports Server (NTRS)
Braman, Julia M. B.; Wagner, David A.
2010-01-01
Safe human exploration in space missions requires careful management of limited resources such as breathable air and stored electrical energy. Daily activities for astronauts must be carefully planned with respect to such resources, and usage must be monitored as activities proceed to ensure that they can be completed while maintaining safe resource margins. Such planning and monitoring can be complex because they depend on models of resource usage, the activities being planned, and uncertainties. This paper describes a system - and the technology behind it - for energy management of the NASA-Johnson Space Center's Multi-Mission Space Exploration Vehicles (SEV), that provides, in an onboard advisory mode, situational awareness to astronauts and real-time guidance to mission operators. This new capability was evaluated during this year's Desert RATS (Research and Technology Studies) planetary exploration analog test in Arizona. This software aided ground operators and crew members in modifying the day s activities based on the real-time execution of the plan and on energy data received from the rovers.
Development of a platform-independent receiver control system for SISIFOS
NASA Astrophysics Data System (ADS)
Lemke, Roland; Olberg, Michael
1998-05-01
Up to now receiver control software was a time consuming development usually written by receiver engineers who had mainly the hardware in mind. We are presenting a low-cost and very flexible system which uses a minimal interface to the real hardware, and which makes it easy to adapt to new receivers. Our system uses Tcl/Tk as a graphical user interface (GUI), SpecTcl as a GUI builder, Pgplot as plotting software, a simple query language (SQL) database for information storage and retrieval, Ethernet socket to socket communication and SCPI as a command control language. The complete system is in principal platform independent but for cost saving reasons we are using it actually on a PC486 running Linux 2.0.30, which is a copylefted Unix. The only hardware dependent part are the digital input/output boards, analog to digital and digital to analog convertors. In the case of the Linux PC we are using a device driver development kit to integrate the boards fully into the kernel of the operating system, which indeed makes them look like an ordinary device. The advantage of this system is firstly the low price and secondly the clear separation between the different software components which are available for many operating systems. If it is not possible, due to CPU performance limitations, to run all the software in a single machine,the SQL-database or the graphical user interface could be installed on separate computers.
Building and Operating Weather Satellite Ground Stations for High School Science. Teachers Guide.
ERIC Educational Resources Information Center
Summers, R. Joe; Gotwald, Timothy
Automatic Picture Transmission (APT) images are real-time weather pictures transmitted from satellites on a radio frequency in a video format. Amateur radio enthusiasts and electronic experimenters have for a number of years designed, built, and operated direct readout stations capable of receiving APT photographs. The equipment to receive weather…
Average Weighted Receiving Time of Weighted Tetrahedron Koch Networks
NASA Astrophysics Data System (ADS)
Dai, Meifeng; Zhang, Danping; Ye, Dandan; Zhang, Cheng; Li, Lei
2015-07-01
We introduce weighted tetrahedron Koch networks with infinite weight factors, which are generalization of finite ones. The term of weighted time is firstly defined in this literature. The mean weighted first-passing time (MWFPT) and the average weighted receiving time (AWRT) are defined by weighted time accordingly. We study the AWRT with weight-dependent walk. Results show that the AWRT for a nontrivial weight factor sequence grows sublinearly with the network order. To investigate the reason of sublinearity, the average receiving time (ART) for four cases are discussed.
Becan, Jennifer E.; Knight, Danica K.; Crawley, Rachel D.; Joe, George W.; Flynn, Patrick M.
2014-01-01
Success in substance abuse treatment is improved by problem recognition, desire to seek help, and readiness to engage in treatment, all of which are important aspects of motivation. Interventions that facilitate these at treatment induction for adolescents are especially needed. The purpose of this study is to assess the effectiveness of TRIP (Treatment Readiness and Induction Program) in promoting treatment motivation. Data represent 519 adolescents from 6 residential programs who completed assessments at treatment intake (Time 1) and 35 days after admission (Time 2). The design consisted of a comparison sample (n = 281) that had enrolled in treatment prior to implementation of TRIP (standard operating practice) and a sample of clients that had entered treatment after TRIP began and received standard operating practice enhanced by TRIP (n = 238). Repeated measures ANCOVAs were conducted using each Time 2 motivation scale as a dependent measure. Motivation scales were conceptualized as representing sequential stages of change. LISREL was used to test a structural model involving TRIP participation, gender, drug use severity, juvenile justice involvement, age, race-ethnicity, prior treatment, and urgency as predictors of the stages of treatment motivation. Compared to standard practice, adolescents receiving TRIP demonstrated greater gains in problem recognition, even after controlling for the other variables in the model. The model fit was adequate, with TRIP directly affecting problem recognition and indirectly affecting later stages of change (desire for help and treatment readiness). Future studies should examine which specific components of TRIP affect change in motivation. PMID:25456094
Chang, Chi-Chang
2013-06-01
To compare the costs of traditional open myomectomy (OM) with laparoscopic myomectomy (LM). A retrospective review was conducted of the medical records of 155 women who underwent traditional open myomectomy (OM) or laparoscopic myomectomy (LM) in a teaching hospital in Taiwan. The total medical service expense and the patient out-of-pocket expense were significantly higher for women who received LM than for women who received OM. However, the operative time and blood loss during surgery were significantly less in women who received LM than in women who received OM. The overall expense is higher for LM than for OM; however, the laparoscopic approach has numerous advantages for patients, including shorter operative time, less blood loss, and a more rapid recovery time. No difference existed in the rate of complications or in the recurrence of disease for the two procedures. Copyright © 2013. Published by Elsevier B.V.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of obligations. Example 2. B operates a program to make loans to small businesses. Depending on the... terms and conditions. For accounting purposes, B classifies the two types of loans as a single class... lender on the loan documents and whose right to receive payment from the payor of record is secured by...
Code of Federal Regulations, 2012 CFR
2012-04-01
... of obligations. Example 2. B operates a program to make loans to small businesses. Depending on the... terms and conditions. For accounting purposes, B classifies the two types of loans as a single class... lender on the loan documents and whose right to receive payment from the payor of record is secured by...
Code of Federal Regulations, 2014 CFR
2014-04-01
... of obligations. Example 2. B operates a program to make loans to small businesses. Depending on the... terms and conditions. For accounting purposes, B classifies the two types of loans as a single class... lender on the loan documents and whose right to receive payment from the payor of record is secured by...
Code of Federal Regulations, 2011 CFR
2011-04-01
... of obligations. Example 2. B operates a program to make loans to small businesses. Depending on the... terms and conditions. For accounting purposes, B classifies the two types of loans as a single class... lender on the loan documents and whose right to receive payment from the payor of record is secured by...
Crypto-Unitary Forms of Quantum Evolution Operators
NASA Astrophysics Data System (ADS)
Znojil, Miloslav
2013-06-01
The description of quantum evolution using unitary operator {u}(t)=exp(-i{h}t) requires that the underlying self-adjoint quantum Hamiltonian {h} remains time-independent. In a way extending the so called {PT}-symmetric quantum mechanics to the models with manifestly time-dependent "charge" {C}(t) we propose and describe an extension of such an exponential-operator approach to evolution to the manifestly time-dependent self-adjoint quantum Hamiltonians {h}(t).
GPS/GLONASS Time Transfer with 20-Channel Dual GNSS Receiver
NASA Technical Reports Server (NTRS)
Daly, P.; Riley, S.
1996-01-01
One of the world's two global navigation systems, the Global Positioning System (GPS), is already fully operational (April 1994) and the other, the Global Navigation Satellite System (GLONASS) will become operational by the end of 1995 or early 1996. Each will offer, independently of the other, precise location and time transfer continuously anywhere in the world and indeed in space itself. Many potential users, in particular the civil aviation community, are keenly interested in a joint GPS/GLONASS operation since it would offer substantial advantages in defining and maintaining the integrity of the navigation aid. Results are presented on the characterization of GPS/GLONASS time comparison using a 20-channel dual receiver developed and constructed at the University of Leeds, UK.
Schenk, Jeannette M; Hunter-Merrill, Rachel; Zheng, Yingye; Etzioni, Ruth; Gulati, Roman; Tangen, Catherine; Thompson, Ian M; Kristal, Alan R
2013-09-01
Although surrogate measures of benign prostatic hyperplasia (BPH) are often used in epidemiologic studies, their performance characteristics are unknown. Using data from the Prostate Cancer Prevention Trial (n = 5,986), we evaluated prostate-specific antigen (PSA), International Prostate Symptom Score (IPSS), and their rates of change as predictors of incident BPH. BPH (n = 842 cases) was defined as medical or surgical treatment or at least 2 IPSS of 15 or higher. Proportional hazards models were used to measure the associations of baseline PSA, IPSS, and their velocities over 2 years with BPH risk, and time-dependent receiver-operating characteristic curves were used to measure their discriminatory performance. Unit increases in PSA, IPSS, and IPSS velocity were associated with 34%, 35%, and 29% (all P < 0.001) increases in BPH risk, respectively. The areas under the receiver-operating characteristic curves were significantly greater than 0.5 for PSA (0.58, 95% confidence interval (CI): 0.56, 0.60), IPSS (0.77, 95% CI: 0.75, 0.78), and IPSS velocity (0.63, 95% CI: 0.61, 0.65); however there were no cut points at which sensitivity and specificity were both above 75%. We concluded that moderate elevations in PSA, IPSS, or their rates of change should not be used as surrogate measures of incident BPH.
Sustainable Model for Public Health Emergency Operations Centers for Global Settings.
Balajee, S Arunmozhi; Pasi, Omer G; Etoundi, Alain Georges M; Rzeszotarski, Peter; Do, Trang T; Hennessee, Ian; Merali, Sharifa; Alroy, Karen A; Phu, Tran Dac; Mounts, Anthony W
2017-10-01
Capacity to receive, verify, analyze, assess, and investigate public health events is essential for epidemic intelligence. Public health Emergency Operations Centers (PHEOCs) can be epidemic intelligence hubs by 1) having the capacity to receive, analyze, and visualize multiple data streams, including surveillance and 2) maintaining a trained workforce that can analyze and interpret data from real-time emerging events. Such PHEOCs could be physically located within a ministry of health epidemiology, surveillance, or equivalent department rather than exist as a stand-alone space and serve as operational hubs during nonoutbreak times but in emergencies can scale up according to the traditional Incident Command System structure.
KvN mechanics approach to the time-dependent frequency harmonic oscillator.
Ramos-Prieto, Irán; Urzúa-Pineda, Alejandro R; Soto-Eguibar, Francisco; Moya-Cessa, Héctor M
2018-05-30
Using the Ermakov-Lewis invariants appearing in KvN mechanics, the time-dependent frequency harmonic oscillator is studied. The analysis builds upon the operational dynamical model, from which it is possible to infer quantum or classical dynamics; thus, the mathematical structure governing the evolution will be the same in both cases. The Liouville operator associated with the time-dependent frequency harmonic oscillator can be transformed using an Ermakov-Lewis invariant, which is also time dependent and commutes with itself at any time. Finally, because the solution of the Ermakov equation is involved in the evolution of the classical state vector, we explore some analytical and numerical solutions.
Study of mathematical modeling of communication systems transponders and receivers
NASA Technical Reports Server (NTRS)
Walsh, J. R.
1972-01-01
The modeling of communication receivers is described at both the circuit detail level and at the block level. The largest effort was devoted to developing new models at the block modeling level. The available effort did not permit full development of all of the block modeling concepts envisioned, but idealized blocks were developed for signal sources, a variety of filters, limiters, amplifiers, mixers, and demodulators. These blocks were organized into an operational computer simulation of communications receiver circuits identified as the frequency and time circuit analysis technique (FATCAT). The simulation operates in both the time and frequency domains, and permits output plots or listings of either frequency spectra or time waveforms from any model block. Transfer between domains is handled with a fast Fourier transform algorithm.
Na, Min Kyun; Won, Yu Deok; Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je Il; Han, Myung-Hoon
2017-01-01
Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13-2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12-16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings.
Remote semi-continuous flow rate logging seepage meter
NASA Technical Reports Server (NTRS)
Reay, William G.; Walthall, Harry G.
1991-01-01
The movement of groundwater and its associated solutes from upland regions was implicated in the degradation of receiving surface water bodies. Current efforts to directly measure this influx of water incorporate manually operated seepage meters which are hindered by severe limitations. A prototype seepage meter was developed by NASA Langley Research Center and Virginia Polytechnic Institute and State University that will allow for the semi-continuous collection and data logging of seepage flux across the sediment water interface. The meter is designed to operate at depths to 40 meters, and alleviate or minimize all disadvantages associated with traditional methods while remaining cost effective. The unit was designed to operate independently for time periods on the order of weeks with adjustable sample sequences depending upon hydrologic conditions. When used in conjunction with commercially available pressure transducers, this seepage meter allows for correlations to be made between groundwater discharge and tidal/sea state conditions in coastal areas. Field data from the Chesapeake Bay and Florida Bay systems are presented.
Range-dependence of acoustic channel with traveling sinusoidal surface wave.
Choo, Youngmin; Seong, Woojae; Lee, Keunhwa
2014-04-01
Range-dependence of time-varying acoustic channels caused by a traveling surface wave is investigated through water tank experiments and acoustic propagation analysis schemes. As the surface wave travels, surface reflected signals fluctuate and the fluctuation varies with source-receiver horizontal range. Amplitude fluctuations of surface reflected signals increase with increasing horizontal range whereas the opposite occurs in delay fluctuations. The scattered pressure field at a fixed time shows strong dependence on the receiver position because of caustics and shadow zones formed by the surface. The Doppler shifts of surface reflected signals also depend on the horizontal range. Comparison between measurement data and model results indicates the Doppler shift relies on the delay fluctuation under current experimental conditions.
Use of early gastrografin small bowel follow-through in small bowel obstruction management.
Galardi, Nicholas; Collins, Jay; Friend, Kara
2013-08-01
Small bowel follow-through (SBFT) is a diagnostic tool commonly used in the management of patients with small bowel obstruction (SBO). This study assessed whether early implementation of Gastrografin SBFT would reduce the time to resolution of the SBO and decrease the time to operative intervention. In this retrospective chart review, 103 patients with the clinical diagnosis of adhesive SBO were evaluated. End points of the study were resolution of SBO with nonoperative management or operative intervention. The patient group that had received a SBFT was then compared with those that did not receive a SBFT. There were 103 patients with adhesive SBO who met inclusion criteria for this study. Seventy-two of 103 patients had undergone Gastrografin SBFT and 31 did not. In the SBFT group, mean time to the operating room was 1.0 days after SBFTs, whereas in the group that did not receive SBFT, it was 3.7 days (P < 0.0001). Mean time to nonoperative resolution of SBO in the SBFT group was 1.8 days and 4.7 days in the no SBFT group (P < 0.0001). There were no Gastrografin-related complications. Obtaining Gastrografin SBFT in patients with adhesive SBO leads to both a shorter time in identifying the need for operative intervention and to resolution of SBO with nonoperative management. SBFT seems to be a more definitive assessment of whether an SBO will resolve on its own or if operative intervention is necessary.
Evaluation of Operator Radioprotection Using a New Injection Device during Vertebroplasty
Nguyen-Kim, L.; Fargeot, C.; Beaussier, H.; Payen, S.; Chiras, J.
2013-01-01
Summary This study aimed to evaluate the protection granted by a simple device (X'TENS®, Thiebaud, France) and to provide operators with information on the performance of this new device, which has not yet been assessed. Our assumption is that this device efficiently reduces the radiation dose to the operator. In a prospective clinical study, the radiation dose the operator's hand receives has been assessed using a specific sensor (UNFOR Instrument). Each patient included in the study was to receive at least two injections of cement during the procedure. Exposure was measured with and without the range extender. The data collected were then processed using a Wilcoxon matched pairs test. During 14 interventions, 20 vertebrae were treated with both procedures. Eleven women and three men were included. Seven patients underwent vertebroplasty for metastatic lesions and seven for osteoporotic lesions, bone fractures or vertebral compressions. The average injection time was 1.35 minutes with the device and 1.20 without (p=0.75). The dose to the hand per ml injected was 111.37 vs. 166.91 (p<0.05). Theoretically, the protection granted by the range extender depends on the length of the device. Our results are consistent with the inverse-square law. However, the variations in our results indicate that a proper and rigorous use is mandatory for the device to be effective. Given that radioprotection during fluoroscopy procedures is a frequently raised issue, the need for information for a safer practice increases likewise. PMID:23693040
Evaluation of operator radioprotection using a new injection device during vertebroplasty.
Nguyen-Kim, L; Fargeot, C; Beaussier, H; Payen, S; Chiras, J
2013-06-01
This study aimed to evaluate the protection granted by a simple device (X'TENS(®), Thiebaud, France) and to provide operators with information on the performance of this new device, which has not yet been assessed. Our assumption is that this device efficiently reduces the radiation dose to the operator. In a prospective clinical study, the radiation dose the operator's hand receives has been assessed using a specific sensor (UNFOR Instrument). Each patient included in the study was to receive at least two injections of cement during the procedure. Exposure was measured with and without the range extender. The data collected were then processed using a Wilcoxon matched pairs test. During 14 interventions, 20 vertebrae were treated with both procedures. Eleven women and three men were included. Seven patients underwent vertebroplasty for metastatic lesions and seven for osteoporotic lesions, bone fractures or vertebral compressions. The average injection time was 1.35 minutes with the device and 1.20 without (p=0.75). The dose to the hand per ml injected was 111.37 vs. 166.91 (p<0.05). Theoretically, the protection granted by the range extender depends on the length of the device. Our results are consistent with the inverse-square law. However, the variations in our results indicate that a proper and rigorous use is mandatory for the device to be effective. Given that radioprotection during fluoroscopy procedures is a frequently raised issue, the need for information for a safer practice increases likewise.
Desferrioxamine: a practical method for improving neovascularization of prefabricated flaps.
Li, Bin; Li, Hua; Jin, Rui; Cheng, Chen; Wang, Jing; Zhu, Hainan; Zan, Tao; Li, Qingfeng; Hao, Lijun
2015-02-01
Prefabricated flaps are an ideal alternative to repair massive and complex tissue defects. Nevertheless, the risk of necrosis due to unpredictable blood supplies is a major obstacle to the application of prefabricated flaps. The survival of a prefabricated flap depends on the neovascularization between the vascular carrier and the donor tissue. Here, we proposed that the iron chelator, desferrioxamine (DFX), owned therapeutic effects that promoted the neovascularization of prefabricated flaps. An abdominal prefabricated flap model was created in rats via a 2-stage operation. The rats were allocated into 4 groups as follows: 2 groups of rats received DFX treatments during the first or the second stage of the operation, respectively; 1 group of rats received a delay procedure 1 week before the second operation; and the final group was used as a blank control. Flap survival rates and capillary densities were evaluated between groups. The influence of DFX on the dermal fibroblasts was also studied in vitro. Desferrioxamine treatment during the first stage of the operation greatly increased flap survival rate compared to the blank control. The results were similar to those produced by the delay treatment. The vessel count results were consistent with the flap survival rate findings. In vitro, DFX treatment up-regulated the expression levels of several angiogenic factors in the dermal fibroblasts. Nevertheless, DFX treatment during the second stage of the operation was therapeutically detrimental. The application of DFX around the time of vascular carrier implantation greatly promoted neovascularization of prefabricated flaps, but was therapeutically detrimental after the flaps had been elevated.
Shavit, Itai; Brant, Rollin; Nijssen-Jordan, Cheri; Galbraith, Roger; Johnson, David W
2006-12-01
Assessment of dehydration in young children currently depends on clinical judgment, which is relatively inaccurate. By using digital videography, we developed a way to assess capillary-refill time more objectively. Our goal was to determine whether digitally measured capillary-refill time assesses the presence of significant dehydration (> or = 5%) in young children with gastroenteritis more accurately than conventional capillary refill and overall clinical assessment. We prospectively enrolled children with gastroenteritis, 1 month to 5 years of age, who were evaluated in a tertiary-care pediatric emergency department and judged by a triage nurse to be at least mildly dehydrated. Before any treatment, we measured the weight and digitally measured capillary-refill time of these children. Pediatric emergency physicians determined capillary-refill time by using conventional methods and degree of dehydration by overall clinical assessment by using a 7-point Likert scale. Postillness weight gain was used to estimate fluid deficit; beginning 48 hours after assessment, children were reweighed every 24 hours until 2 sequential weights differed by no more than 2%. We compared the accuracy of digitally measured capillary-refill time with conventional capillary refill and overall clinical assessment by determining sensitivities, specificities, likelihood ratios, and area under the receiver operator characteristic curves. A total of 83 patients were enrolled and had complete follow-up; 13 of these patients had significant dehydration (> or = 5% of body weight). The area under the receiver operator characteristic curves for digitally measured capillary-refill time and overall clinical assessment relative to fluid deficit (< 5% vs > or = 5%) were 0.99 and 0.88, respectively. Positive likelihood ratios were 11.7 for digitally measured capillary-refill time, 4.5 for conventional capillary refill, and 4.1 for overall clinical assessment. Results of this prospective cohort study suggest that digitally measured capillary-refill time more accurately predicts significant dehydration (> or = 5%) in young children with gastroenteritis than overall clinical assessment.
NaK pool-boiler bench-scale receiver durability test: Test results and materials analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andraka, C.E.; Goods, S.H.; Bradshaw, R.W.
1994-06-01
Pool-boiler reflux receivers have been considered as an alternative to heat pipes for the input of concentrated solar energy to Stirling-cycle engines in dish-Stirling electric generation systems. Pool boilers offer simplicity in design and fabrication. The operation of a full-scale pool-boiler receiver has been demonstrated for short periods of time. However, to generate cost-effective electricity, the receiver must operate Without significant maintenance for the entire system life, as much as 20 to 30 years. Long-term liquid-metal boiling stability and materials compatibility with refluxing NaK-78 is not known and must be determined for the pool boiler receiver. No boiling system hasmore » been demonstrated for a significant duration with the current porous boiling enhancement surface and materials. Therefore, it is necessary to simulate the full-scale pool boiler design as much as possible, including flux levels, materials, and operating cycles. On-sun testing is impractical because of the limited test time available. A test vessel was constructed with a porous boiling enhancement surface. The boiling surface consisted of a brazed stainless steel powder with about 50% porosity. The vessel was heated with a quartz lamp array providing about go W/CM2 peak incident thermal flux. The vessel was charged with NaK-78. This allows the elimination of costly electric preheating, both on this test and on fullscale receivers. The vessel was fabricated from Haynes 230 alloy. The vessel operated at 750{degrees}C around the clock, with a 1/2-hour shutdown cycle to ambient every 8 hours. The test completed 7500 hours of lamp-on operation time, and over 1000 startups from ambient. The test was terminated when a small leak in an Inconel 600 thermowell was detected. The test design and data are presented here. Metallurgical analysis of virgin and tested materials has begun, and initial results are also presented.« less
Alizadeh, Maryam; Zahedi-Khorasani, Mahdi; Miladi-Gorji, Hossein
2018-05-30
This study was designed to examine whether treadmill exercise would attenuate the severity of physical dependence, methadone-induced anxiety, depression and voluntary morphine consumption in morphine withdrawn rats receiving methadone maintenance treatment (MMT). The rats were chronically treated with bi-daily doses (10 mg/kg, at 12 h intervals) of morphine for 14 days. The exercising rats receiving MMT were forced to run on a motorized treadmill for 30 days during morphine withdrawal. Then, rats were tested for the severity of morphine dependence, the elevated plus-maze (EPM), sucrose preference test (SPT) and voluntary morphine consumption using a two-bottle choice (TBC) paradigm. The results showed that naloxone- precipitated opioid withdrawal signs were decreased in exercising morphine-dependent rats receiving MMT than sedentary rats. Also, the exercising morphine-dependent rats receiving MMT exhibited an increased time on open arms, preference for sucrose and a lower morphine preference ratio than sedentary rats. We conclude that treadmill exercise decreased the severity of physical dependence, anxiety/depressive-like behaviors and also the voluntary morphine consumption in morphine withdrawn rats receiving MMT. Thus, exercise may benefit in the treatment of addicts during MMT. Copyright © 2018. Published by Elsevier B.V.
Numerical Solution of Time-Dependent Problems with a Fractional-Power Elliptic Operator
NASA Astrophysics Data System (ADS)
Vabishchevich, P. N.
2018-03-01
A time-dependent problem in a bounded domain for a fractional diffusion equation is considered. The first-order evolution equation involves a fractional-power second-order elliptic operator with Robin boundary conditions. A finite-element spatial approximation with an additive approximation of the operator of the problem is used. The time approximation is based on a vector scheme. The transition to a new time level is ensured by solving a sequence of standard elliptic boundary value problems. Numerical results obtained for a two-dimensional model problem are presented.
Neighbors, Charles J.; Kuerbis, Alexis; Riordan, Annette; Blanchard, Kimberly A.; McVeigh, Katharine H.; Morgan, Thomas J.; McCrady, Barbara
2009-01-01
Objective. We examined abstinence rates among substance-dependent women receiving Temporary Assistance for Needy Families (TANF) in intensive case management (ICM) over 24 months and whether ICM yielded significantly better employment outcomes compared with a screen-and-refer program (i.e., usual care). Methods. Substance-dependent (n = 302) and non–substance dependent (n = 150) TANF applicants in Essex County, New Jersey, were recruited. We randomly assigned substance-dependent women to ICM or usual care. We interviewed all women at 3, 9, 15, and 24 months. Results. Abstinence rates were higher for the ICM group than for the usual care group through 24 months of follow-up (odds ratio [OR] = 2.11; 95% confidence interval [CI] = 1.36, 3.29). A statistically significant interaction between time and group on number of days employed indicated that the rate of improvement over time in employment was greater for the ICM group than for the usual care group (incidence rate ratio = 1.03; 95% CI = 1.02, 1.04). Additionally, there were greater odds of being employed full time for those in the ICM group (OR = 1.68; 95% CI = 1.12, 2.51). Conclusions. ICM is a promising intervention for managing substance dependence among women receiving TANF and for improving employment rates among this vulnerable population. PMID:19059855
NASA Astrophysics Data System (ADS)
Vetrov, A.; Mejzr, I.
2010-12-01
While developing a new Helicopter Time Domain Electromagnetic system (P-THEM), Pico Envirotec Inc (PEI) has studied the effect of the transmitter assembly on the acquired data. The P-THEM system consists of a loop-transmitter assembly, powered by a motor generator, 3-axis coil receiver attached at the midpoint of a tow cable and an additional Z-axis (dB/dt) receiver installed on the rear section of the transmitter loop. The system is towed by a helicopter on a 230 foot long tow cable. The transmitter loop is designed to produce a peak magnetic moment of approximately 250,000 NIA with a base frequency of 30 Hz (adjustable to 25Hz) and a quarter length duty cycle (4 ms on-time). The secondary field acquired with a dB/dt receiver coil consists of a ground response and a system response: SF=Rg+Rsys, where SF - the secondary field, Rg - ground response, Rsys - system response. The system itself, especially the transmitter assembly, being a conductor in an induced magnetic field, creates a magnetic anomaly. The influence of the transmitter assembly anomaly on the received signal depends on the position of the receiver coil against the transmitter, the intensity of on-time pulse and transmitter electro-magnetic properties. At the same time, the ground response acquired with a receiver coil depends on the length and the moment of transmitter pulse, as well as the position and distance of the receiver coil from the ground. This can be for vertical field (Z) receiver coil described as RXz(t)=e(t)pz(t)Rgz(t)+d(t)k(t)j(t)TXz(t), where RXz(t) - receiver response, e(t) - elevation of the receiver over the ground, pz(t) - horizontal projection of the receiver coil, Rgz(t) - vertical component of ground response, d(t) - distance (elevation) between the receiver coil and the transmitter loop, k(t) - the position of the receiver in the transmitter field, j(t) - the transmitter assembly electromagnetic properties, TXz(t) -transmitter field (Primary field on-time, and transmitter assembly response off-time). Changes in the electromagnetic properties of the transmitter loop and mechanical vibrations of the transmitter and receiver are much lower frequency in comparison with the base frequency and can be omitted from consideration of a one cycle length period. The transmitter assembly response has to be subtracted from acquired off-time decay for a correct interpretation of ground response. The transmitter influence is very low when the receiving coil is placed far away. However, the transmitter influence is very important when the receiver is close to the transmitter assembly due to the transmitter anomaly decay which then becomes greater than the ground response. The transmitter assembly off-time response can be registered when the system is flown at a sufficiently high altitude and it is not affected by ground conductors. A number of experiments were conducted to determine the transmitter influence content in the acquired data. The secondary dB/dt receiver installed at different elevations over the transmitter loop in test flights It showed the influence change of the transmitter assembly on the acquired secondary field (OFF-time) dependent upon the distance between the transmitter assembly and the receiver loop.
Li, Jing; Pan, Qunwan; Zhu, Zaiman; Li, Min; Bai, Yu; Yu, Ran
2015-05-01
To investigate the changes of telemetry electrical activity in the infralimbic cortex (IL) of morphine-dependent rats with extinguished drug-seeking behavior. SD rats were randomly divided into model group and control group and received operations of brain stereotaxic electrode embedding in the IL. The rats in the model group were induced to acquire morphine dependence and then received subsequent extinction training, and the changes of electrical activity in the IL were recorded with a physical wireless telemetry system. In rats with morphine dependence, the time staying in the white box was significantly longer on days 1 and 2 after withdrawal than that before morphine injection and that of the control rats, but was obviously reduced on days 1 and 2 after extinction training to the control level. Compared with the control group, the morphine-dependent rats on day 2 following withdrawal showed significantly increased β wave and decreased δ wave when they stayed in the white box but significantly increased δ wave and decreased α wave and β wave when they shuttled from the black to the white box. On day 2 of extinction, the model rats, when staying in the white box, showed significantly decreased θ wave compared with that of the control rats group but decreased β wave and θ wave and increased δ wave compared with those in the withdrawal period. When they shuttled from black to white box, the model rats showed decreased δ wave and increased α wave and β wave compared with those in the withdrawal period. Morphine-dependent rats have abnormal changes of electrical activity in the IL in drug-seeking extinction to affect their drug-seeking motive and inhibit the expression and maintenance of drug-seeking behaviors.
[The effect of parecoxib sodium for preemptive analgesia on nasal endoscopic surgery].
Kong, Yonggang; Yang, Xilin; Li, Xinchu
2015-08-01
To evaluate the perioperative analgesic effects of parecoxib sodium in patients undergoing nasal endoscopic surgery. In the randomized, double blind, controlled study, 120 patients undergoing septoplasty were divided into 3 groups (n = 40): A group received parecoxib at a dose of 40 mg by muscle injection 30 min before the operation followed by saline at the same volume every 24 h for 48 h; B group received parecoxib at a dose of 40 mg by muscle injection 30 min before the operation followed by 40 mg every 24 h for 48 h; C group received an equal volume of 0.9% saline at the same time points. Patients were assessed with respect to pain score (VAS), rescue analgesia requirement and the side effects during the operation as well as at 3, 24, 48 h after the surgery. Intra-operative as well as the postoperative pain scores were less in the A group and B group than in the.control group. Compared with group A, group B had significantly lower VAS score at 24 h after the operation, however there were no significant difference on other time points. Fewer participants of both the A and B groups required rescue medication after operation. Administration of parecoxib can provide ideal analgesic effects without serious adverse side effects at the perioperative period for patients who received nasal endoscopic operation. Intramuscular parecoxib (40 mg 30 min before the operation followed 40 mg qd for 48 h) designed as preoperative analgesia mode resulted in sufficient perioperative analgesia that deserves popularization in the clinical works.
System and method for time synchronization in a wireless network
Gonia, Patrick S.; Kolavennu, Soumitri N.; Mahasenan, Arun V.; Budampati, Ramakrishna S.
2010-03-30
A system includes multiple wireless nodes forming a cluster in a wireless network, where each wireless node is configured to communicate and exchange data wirelessly based on a clock. One of the wireless nodes is configured to operate as a cluster master. Each of the other wireless nodes is configured to (i) receive time synchronization information from a parent node, (ii) adjust its clock based on the received time synchronization information, and (iii) broadcast time synchronization information based on the time synchronization information received by that wireless node. The time synchronization information received by each of the other wireless nodes is based on time synchronization information provided by the cluster master so that the other wireless nodes substantially synchronize their clocks with the clock of the cluster master.
A real-time chirp-coded imaging system with tissue attenuation compensation.
Ramalli, A; Guidi, F; Boni, E; Tortoli, P
2015-07-01
In ultrasound imaging, pulse compression methods based on the transmission (TX) of long coded pulses and matched receive filtering can be used to improve the penetration depth while preserving the axial resolution (coded-imaging). The performance of most of these methods is affected by the frequency dependent attenuation of tissue, which causes mismatch of the receiver filter. This, together with the involved additional computational load, has probably so far limited the implementation of pulse compression methods in real-time imaging systems. In this paper, a real-time low-computational-cost coded-imaging system operating on the beamformed and demodulated data received by a linear array probe is presented. The system has been implemented by extending the firmware and the software of the ULA-OP research platform. In particular, pulse compression is performed by exploiting the computational resources of a single digital signal processor. Each image line is produced in less than 20 μs, so that, e.g., 192-line frames can be generated at up to 200 fps. Although the system may work with a large class of codes, this paper has been focused on the test of linear frequency modulated chirps. The new system has been used to experimentally investigate the effects of tissue attenuation so that the design of the receive compression filter can be accordingly guided. Tests made with different chirp signals confirm that, although the attainable compression gain in attenuating media is lower than the theoretical value expected for a given TX Time-Bandwidth product (BT), good SNR gains can be obtained. For example, by using a chirp signal having BT=19, a 13 dB compression gain has been measured. By adapting the frequency band of the receiver to the band of the received echo, the signal-to-noise ratio and the penetration depth have been further increased, as shown by real-time tests conducted on phantoms and in vivo. In particular, a 2.7 dB SNR increase has been measured through a novel attenuation compensation scheme, which only requires to shift the demodulation frequency by 1 MHz. The proposed method characterizes for its simplicity and easy implementation. Copyright © 2015 Elsevier B.V. All rights reserved.
Comparison of GLONASS and GPS Time Transfers
NASA Astrophysics Data System (ADS)
Daly, P.; Koshelyaevsky, N. B.; Lewandowski, W.; Petit, G.; Thomas, C.
1993-01-01
The Russian global space navigation system GLONASS could provide a technique similar to GPS for international time comparison. The main limitation to its use for time transfer is the lack of commercially available time receivers. The University of Leeds built a GPS/GLONASS receiver five years ago and since then has provided continuous information about GLONASS time and its comparison with GPS time. For the last two years the VNIIFTRI and several other Russian time laboratories have used Russian-built GLONASS navigation receivers for time comparisons. Since June 1991, the VNIIFTRI has operated a GPS time receiver which offers, for the first time, an opportunity for the direct comparison of time transfers using GPS and GLONASS. This seven-month experiment shows that even with relatively imprecise data recording and processing, in terms of time metrology, GLONASS can provide continental time transfer at a level of several tens of nanoseconds.
Becan, Jennifer E; Knight, Danica K; Crawley, Rachel D; Joe, George W; Flynn, Patrick M
2015-03-01
Success in substance abuse treatment is improved by problem recognition, desire to seek help, and readiness to engage in treatment, all of which are important aspects of motivation. Interventions that facilitate these at treatment induction for adolescents are especially needed. The purpose of this study is to assess the effectiveness of TRIP (Treatment Readiness and Induction Program) in promoting treatment motivation. Data represent 519 adolescents from 6 residential programs who completed assessments at treatment intake (time 1) and 35 days after admission (time 2). The design consisted of a comparison sample (n=281) that had enrolled in treatment prior to implementation of TRIP (standard operating practice) and a sample of clients that had entered treatment after TRIP began and received standard operating practice enhanced by TRIP (n=238). Repeated measures ANCOVAs were conducted using each time 2 motivation scale as a dependent measure. Motivation scales were conceptualized as representing sequential stages of change. LISREL was used to test a structural model involving TRIP participation, gender, drug use severity, juvenile justice involvement, age, race-ethnicity, prior treatment, and urgency as predictors of the stages of treatment motivation. Compared to standard practice, adolescents receiving TRIP demonstrated greater gains in problem recognition, even after controlling for the other variables in the model. The model fit was adequate, with TRIP directly affecting problem recognition and indirectly affecting later stages of change (desire for help and treatment readiness). Future studies should examine which specific components of TRIP affect change in motivation. Copyright © 2015 Elsevier Inc. All rights reserved.
Ródenas, J; Zarza, I; Burgos, M C; Felipe, A; Sánchez-Mayoral, M L
2004-01-01
Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed.
Ecology and IPM of Insects at Grain Elevators
USDA-ARS?s Scientific Manuscript database
Cost-effectiveness of insect pest management depends upon its integration with other elevator operations. Successful integration may require consideration of insect ecology. Field infestation has not been observed for grain received at elevators. Grain may be infested during harvest by residual inse...
Waveform Synthesizer For Imaging And Ranging Applications
DUDLEY, PETER A.; [et al
2004-11-30
Frequency dependent corrections are provided for quadrature imbalance. An operational procedure filters imbalance effects without prior calibration or equalization. Waveform generation can be adjusted/corrected in a synthetic aperture radar system (SAR), where a rolling phase shift is applied to the SAR's QDWS signal where it is demodulated in a receiver; unwanted energies, such as imbalance energy, are separated from a desired signal in Doppler; the separated energy is filtered from the receiver leaving the desired signal; and the separated energy in the receiver is measured to determine the degree of imbalance that is represented by it. Calibration methods can also be implemented into synthesis. The degree of quadrature imbalance can be used to determine calibration values that can then be provided as compensation for frequency dependent errors in components, such as the QDWS and SSB mixer, affecting quadrature signal quality.
Zhang, Yeqing; Wang, Meiling; Li, Yafeng
2018-01-01
For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90–94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7–5.6% per millisecond, with most satellites acquired successfully. PMID:29495301
Zhang, Yeqing; Wang, Meiling; Li, Yafeng
2018-02-24
For the objective of essentially decreasing computational complexity and time consumption of signal acquisition, this paper explores a resampling strategy and variable circular correlation time strategy specific to broadband multi-frequency GNSS receivers. In broadband GNSS receivers, the resampling strategy is established to work on conventional acquisition algorithms by resampling the main lobe of received broadband signals with a much lower frequency. Variable circular correlation time is designed to adapt to different signal strength conditions and thereby increase the operation flexibility of GNSS signal acquisition. The acquisition threshold is defined as the ratio of the highest and second highest correlation results in the search space of carrier frequency and code phase. Moreover, computational complexity of signal acquisition is formulated by amounts of multiplication and summation operations in the acquisition process. Comparative experiments and performance analysis are conducted on four sets of real GPS L2C signals with different sampling frequencies. The results indicate that the resampling strategy can effectively decrease computation and time cost by nearly 90-94% with just slight loss of acquisition sensitivity. With circular correlation time varying from 10 ms to 20 ms, the time cost of signal acquisition has increased by about 2.7-5.6% per millisecond, with most satellites acquired successfully.
Use of GPS ASHTECH Z12T receivers for accurate time and frequency comparisons.
Petit, G; Thomas, C; Jiang, Z; Uhrich, P; Taris, F
1999-01-01
The GPS phase measurements described in this paper were obtained using two similar multichannel GPS ASHTECH Z12T receivers belonging to the Bureau International des Poids et Mesures, BIPM, and the Laboratoire Primaire du Temps et des Frequences, BNM-LPTF. These receivers are based on the conventional geodetic ASHTECH Z12 unit, which has been modified to meet the stability requirements of time and frequency comparisons. Comparison of the two receivers operated side by side in different antenna configurations shows typical short-term noise of 1.1 to 3.5 ps. Longer term variations indicate a temperature sensitivity in the equipment, which limits the performance of the GPS phase method. One of the receivers was successfully operated using a temperature-stabilized antenna TSA from 3S Navigation, and the ASHTECH antenna, which feeds the second receiver, was placed in a home-built oven maintained at a constant temperature. These precautions made it possible to reduce a number of systematic effects. A separate study of frequency comparison was carried out between two hydrogen-masers located at the BNM-LPTF (Paris, France) and the PTB (Braunschweig, Germany) using receivers similar to ASHTECH Z12T receivers. The relative frequency stability obtained was about 3.3x10(-15) for an average time of 15 000 s, an interesting result comparable with the outstanding performance of new ultrastable frequency standards.
A Guide to Safe Field Operations
1996-01-01
be dangerous depending on the type of insect and your reaction to their sting or bite. Stinging insects, which include honey bees , killer bees ...and operational policies of the WRD to ensure that (1) their activities avoid or minimize personal injury to the employee, coworkers, or anyone in...assignments with minimal chance of personal injury or infringement on the rights of others. However, once you have received training and have been
Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je il
2017-01-01
Background and purpose Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Methods Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. Results We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13–2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Conclusions Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12–16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings. PMID:29232410
2014-01-01
Background The Alcohol Use Disorders Identification Test (AUDIT) is a 10-item alcohol screener that has been recommended for use in Aboriginal primary health care settings. The time it takes respondents to complete AUDIT, however, has proven to be a barrier to its routine delivery. Two shorter versions, AUDIT-C and AUDIT-3, have been used as screening instruments in primary health care. This paper aims to identify the AUDIT-C and AUDIT-3 cutoff scores that most closely identify individuals classified as being at-risk drinkers, high-risk drinkers, or likely alcohol dependent by the 10-item AUDIT. Methods Two cross-sectional surveys were conducted from June 2009 to May 2010 and from July 2010 to June 2011. Aboriginal Australian participants (N = 156) were recruited through an Aboriginal Community Controlled Health Service, and a community-based drug and alcohol treatment agency in rural New South Wales (NSW), and through community-based Aboriginal groups in Sydney NSW. Sensitivity, specificity, and positive and negative predictive values of each score on the AUDIT-C and AUDIT-3 were calculated, relative to cutoff scores on the 10-item AUDIT for at-risk, high-risk, and likely dependent drinkers. Receiver operating characteristic (ROC) curve analyses were conducted to measure the detection characteristics of AUDIT-C and AUDIT-3 for the three categories of risk. Results The areas under the receiver operating characteristic (AUROC) curves were high for drinkers classified as being at-risk, high-risk, and likely dependent. Conclusions Recommended cutoff scores for Aboriginal Australians are as follows: at-risk drinkers AUDIT-C ≥ 5, AUDIT-3 ≥ 1; high-risk drinkers AUDIT-C ≥ 6, AUDIT-3 ≥ 2; and likely dependent drinkers AUDIT-C ≥ 9, AUDIT-3 ≥ 3. Adequate sensitivity and specificity were achieved for recommended cutoff scores. AUROC curves were above 0.90. PMID:25179547
Springback compensation for a vehicle's steel body panel
NASA Astrophysics Data System (ADS)
Bałon, Paweł; Świątoniowski, Andrzej; Szostak, Janusz; Kiełbasa, Bartłomiej
2017-10-01
This paper presents a structural element of a vehicle, that is made from High Strength Steels. Application of this kind of materials considerably reduces construction mass due to high durability. Nevertheless, it results in appearance of springback that depends mainly on used material as well as part. Springback reduction helps to reach the reference geometry of the element by using the Finite Element Method software. Authors compared two methods of optimization of die shape. The first method defines the compensation of the die shape only for OP-20 and the second multi-operation method defines the compensation of the die shape for the OP-20 and OP-50 operations. Prediction of springback by the trial-and-error method is difficult and labor-intensive. Designing of dies requires using of appropriate FEM software to make them more economic and less time-consuming. Virtual compensation methods make it possible to receive precise result in a short time. Die compensation with software application was experimentally verified by the prototype die. Therefore, springback deformation becomes a critical problem especially for the HSS steel when the geometry is complex.
Ground station software for receiving and handling Irecin telemetry data
NASA Astrophysics Data System (ADS)
Ferrante, M.; Petrozzi, M.; Di Ciolo, L.; Ortenzi, A.; Troso, G
2004-11-01
The on board resources, needed to perform the mission tasks, are very limited in nano-satellites. This paper proposes a software system to receive, manage and process in Real Time the Telemetry data coming from IRECIN nanosatellite and transmit operator manual commands and operative procedures. During the receiving phase, it shows the IRECIN subsystem physical values, visualizes the IRECIN attitude, and performs other suitable functions. The IRECIN Ground Station program is in charge to exchange information between IRECIN and the Ground segment. It carries out, in real time during IRECIN transmission phase, IRECIN attitude drawing, sun direction drawing, power supply received from Sun, visualization of the telemetry data, visualization of Earth magnetic field and more other functions. The received data are memorized and interpreted by a module, parser, and distribute to the suitable modules. Moreover it allows sending manual and automatic commands. Manual commands are delivered by an operator, on the other hand, automatic commands are provided by pre-configured operative procedures. Operative procedures development is realized in a previous phase called configuration phase. This program is also in charge to carry out a test session by mean the scheduler and commanding modules allowing execution of specific tasks without operator control. A log module to memorize received and transmitted data is realized. A phase to analyze, filter and visualize in off line the collected data, called post analysis, is based on the data extraction form the log module. At the same time, the Ground Station Software can work in network allowing managing, receiving and sending data/commands from different sites. The proposed system constitutes the software of IRECIN Ground Station. IRECIN is a modular nanosatellite weighting less than 2 kg, constituted by sixteen external sides with surface-mounted solar cells and three internal Al plates, kept together by four steel bars. Lithium-ions batteries are used. Attitude is determined by two three-axis magnetometers and the solar panels data. Control is provided by an active magnetic control system. The spacecraft will be spin- stabilized with the spin-axis normal to the orbit. All IRECIN electronic components are SMD technology in order to reduce weight and size. The realized Electronic board are completely developed, realized and tested at the Vitrociset S.P.A. under control of Research and Develop Group
Experimental Quantum-Walk Revival with a Time-Dependent Coin
NASA Astrophysics Data System (ADS)
Xue, P.; Zhang, R.; Qin, H.; Zhan, X.; Bian, Z. H.; Li, J.; Sanders, Barry C.
2015-04-01
We demonstrate a quantum walk with time-dependent coin bias. With this technique we realize an experimental single-photon one-dimensional quantum walk with a linearly ramped time-dependent coin flip operation and thereby demonstrate two periodic revivals of the walker distribution. In our beam-displacer interferometer, the walk corresponds to movement between discretely separated transverse modes of the field serving as lattice sites, and the time-dependent coin flip is effected by implementing a different angle between the optical axis of half-wave plate and the light propagation at each step. Each of the quantum-walk steps required to realize a revival comprises two sequential orthogonal coin-flip operators, with one coin having constant bias and the other coin having a time-dependent ramped coin bias, followed by a conditional translation of the walker.
Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.
Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime
2017-12-01
Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Metric versus observable operator representation, higher spin models
NASA Astrophysics Data System (ADS)
Fring, Andreas; Frith, Thomas
2018-02-01
We elaborate further on the metric representation that is obtained by transferring the time-dependence from a Hermitian Hamiltonian to the metric operator in a related non-Hermitian system. We provide further insight into the procedure on how to employ the time-dependent Dyson relation and the quasi-Hermiticity relation to solve time-dependent Hermitian Hamiltonian systems. By solving both equations separately we argue here that it is in general easier to solve the former. We solve the mutually related time-dependent Schrödinger equation for a Hermitian and non-Hermitian spin 1/2, 1 and 3/2 model with time-independent and time-dependent metric, respectively. In all models the overdetermined coupled system of equations for the Dyson map can be decoupled algebraic manipulations and reduces to simple linear differential equations and an equation that can be converted into the non-linear Ermakov-Pinney equation.
Fu, Shangxi; Liu, Xiao; Zhou, Li; Zhou, Meisheng; Wang, Liming
2017-08-01
The purpose of this study was to estimate the effects of surgical laparoscopic operation course on laparoscopic operation skills after the simulated training for medical students with relatively objective results via data gained before and after the practice course of laparoscopic simulator of the resident standardized trainees. Experiment 1: 20 resident standardized trainees with no experience in laparoscopic surgery were included in the inexperienced group and finished simulated cholecystectomy according to simulator videos. Simulator data was collected (total operation time, path length, average speed of instrument movement, movement efficiency, number of perforations, the time cautery is applied without appropriate contact with adhesions, number of serious complications). Ten attending doctors were included in the experienced group and conducted the operation of simulated cholecystectomy directly. Data was collected with simulator. Data of two groups was compared. Experiment 2: Participants in inexperienced group were assigned to basic group (receiving 8 items of basic operation training) and special group (receiving 8 items of basic operation training and 4 items of specialized training), and 10 persons for each group. They received training course designed by us respectively. After training level had reached the expected target, simulated cholecystectomy was performed, and data was collected. Experimental data between basic group and special group was compared and then data between special group and experienced group was compared. Results of experiment 1 showed that there is significant difference between data in inexperienced group in which participants operated simulated cholecystectomy only according to instructors' teaching and operation video and data in experienced group. Result of experiment 2 suggested that, total operation time, number of perforations, number of serious complications, number of non-cauterized bleeding and the time cautery is applied without appropriate contact with adhesions in special group were all superior to those in basic group. There was no statistical difference on other data between special group and basic group. Comparing special group with experienced group, data of total operation time and the time cautery is applied without appropriate contact with adhesions in experienced group was superior to that in special group. There was no statistical difference on other data between special group and experienced group. Laparoscopic simulators are effective for surgical skills training. Basic courses could mainly improve operator's hand-eye coordination and perception of sense of the insertion depth for instruments. Specialized training courses could not only improve operator's familiarity with surgeries, but also reduce operation time and risk, and improve safety.
NASA Astrophysics Data System (ADS)
Takanashi, Masaki; Nishimura, Toshihiko; Ogawa, Yasutaka; Ohgane, Takeo
Ultrawide-band impulse radio (UWB-IR) technology and multiple-input multiple-output (MIMO) systems have attracted interest regarding their use in next-generation high-speed radio communication. We have studied the use of MIMO ultrawide-band (MIMO-UWB) systems to enable higher-speed radio communication. We used frequency-domain equalization based on the minimum mean square error criterion (MMSE-FDE) to reduce intersymbol interference (ISI) and co-channel interference (CCI) in MIMO-UWB systems. Because UWB systems are expected to be used for short-range wireless communication, MIMO-UWB systems will usually operate in line-of-sight (LOS) environments and direct waves will be received at the receiver side. Direct waves have high power and cause high correlations between antennas in such environments. Thus, it is thought that direct waves will adversely affect the performance of spatial filtering and equalization techniques used to enhance signal detection. To examine the feasibility of MIMO-UWB systems, we conducted MIMO-UWB system propagation measurements in LOS environments. From the measurements, we found that the arrival time of direct waves from different transmitting antennas depends on the MIMO configuration. Because we can obtain high power from the direct waves, direct wave reception is critical for maximizing transmission performance. In this paper, we present our measurement results, and propose a way to improve performance using a method of transmit (Tx) and receive (Rx) timing control. We evaluate the bit error rate (BER) performance for this form of timing control using measured channel data.
Adaptive reconfigurable V-BLAST type equalizer for cognitive MIMO-OFDM radios
NASA Astrophysics Data System (ADS)
Ozden, Mehmet Tahir
2015-12-01
An adaptive channel shortening equalizer design for multiple input multiple output-orthogonal frequency division multiplexing (MIMO-OFDM) radio receivers is considered in this presentation. The proposed receiver has desirable features for cognitive and software defined radio implementations. It consists of two sections: MIMO decision feedback equalizer (MIMO-DFE) and adaptive multiple Viterbi detection. In MIMO-DFE section, a complete modified Gram-Schmidt orthogonalization of multichannel input data is accomplished using sequential processing multichannel Givens lattice stages, so that a Vertical Bell Laboratories Layered Space Time (V-BLAST) type MIMO-DFE is realized at the front-end section of the channel shortening equalizer. Matrix operations, a major bottleneck for receiver operations, are accordingly avoided, and only scalar operations are used. A highly modular and regular radio receiver architecture that has a suitable structure for digital signal processing (DSP) chip and field programable gate array (FPGA) implementations, which are important for software defined radio realizations, is achieved. The MIMO-DFE section of the proposed receiver can also be reconfigured for spectrum sensing and positioning functions, which are important tasks for cognitive radio applications. In connection with adaptive multiple Viterbi detection section, a systolic array implementation for each channel is performed so that a receiver architecture with high computational concurrency is attained. The total computational complexity is given in terms of equalizer and desired response filter lengths, alphabet size, and number of antennas. The performance of the proposed receiver is presented for two-channel case by means of mean squared error (MSE) and probability of error evaluations, which are conducted for time-invariant and time-variant channel conditions, orthogonal and nonorthogonal transmissions, and two different modulation schemes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerhart, T.N.; Yett, H.S.; Robertson, L.K.
In a randomized, prospective trial, a low-molecular-weight heparinoid (Org 10172 (Lomoparan)) was compared with warfarin for efficacy and safety in preventing deep-vein thrombosis in 263 patients who had an operatively treated fracture of the hip. One group of patients received Org 10172 in a dose of 750 units subcutaneously every twelve hours until the ninth postoperative day; on the seventh postoperative day, warfarin was added to the regimen. The other group received only warfarin. Both drugs were begun preoperatively, immediately after the admission evaluation. In the patients who received warfarin, the desired prothrombin time was one and one-half times themore » control level. Deep-vein thrombosis was detected by {sup 125}I-fibrinogen scanning and impedance plethysmography and was confirmed by phlebography and compression ultrasonography. Deep-vein thrombosis was found in nine (7 per cent) of the 132 patients who received Org 10172 and in twenty-eight (21 per cent) of the 131 patients who received warfarin (p less than 0.001). Adverse reactions were not significantly different in the two groups. Major bleeding complications occurred in eight patients in the Org-10172 group, only four of whom were receiving the drug at the time of bleeding, and in five patients who were receiving warfarin (not significant). There was no difference in intraoperative loss of blood or in requirements for transfusion. We concluded that the low-molecular-weight heparinoid Org 10172 is a safe, convenient, effective antithrombotic agent for the prevention of venous thrombosis after an operation for fracture of the hip.« less
McPherson, Jacob G.; Miller, Robert R.; Perlmutter, Steve I.
2015-01-01
Use-dependent movement therapies can lead to partial recovery of motor function after neurological injury. We attempted to improve recovery by developing a neuroprosthetic intervention that enhances movement therapy by directing spike timing-dependent plasticity in spared motor pathways. Using a recurrent neural–computer interface in rats with a cervical contusion of the spinal cord, we synchronized intraspinal microstimulation below the injury with the arrival of functionally related volitional motor commands signaled by muscle activity in the impaired forelimb. Stimulation was delivered during physical retraining of a forelimb behavior and throughout the day for 3 mo. Rats receiving this targeted, activity-dependent spinal stimulation (TADSS) exhibited markedly enhanced recovery compared with animals receiving targeted but open-loop spinal stimulation and rats receiving physical retraining alone. On a forelimb reach and grasp task, TADSS animals recovered 63% of their preinjury ability, more than two times the performance level achieved by the other therapy groups. Therapeutic gains were maintained for 3 additional wk without stimulation. The results suggest that activity-dependent spinal stimulation can induce neural plasticity that improves behavioral recovery after spinal cord injury. PMID:26371306
Reichelt-Brushett, Amanda J; Stone, Jane; Howe, Pelli; Thomas, Bernard; Clark, Malcolm; Male, Yusthinus; Nanlohy, Albert; Butcher, Paul
2017-01-01
Artisanal small-scale gold mining (ASGM) using mercury (Hg) amalgamation has been occurring on Buru Island, Indonesia since early 2012, and has caused rapid accumulation of high Hg concentrations in river, estuary and marine sediments. In this study, sediment samples were collected from several sites downstream of the Mount Botak ASGM site, as well as in the vicinity of the more recently established site at Gogrea where no sampling had previously been completed. All sediment samples had total Hg (THg) concentrations exceeding Indonesian sediment quality guidelines and were up to 82 times this limit at one estuary site. The geochemistry of sediments in receiving environments indicates the potential for Hg-methylation to form highly bioavailable Hg species. To assess the current contamination threat from consumption of local seafood, samples of fish, molluscs and crustaceans were collected from the Namlea fish market and analysed for THg concentrations. The majority of edible tissue samples had elevated THg concentrations, which raises concerns for food safety. This study shows that river, estuary and marine ecosystems downstream of ASGM operations on Buru Island are exposed to dangerously high Hg concentrations, which are impacting aquatic food chains, and fisheries resources. Considering the high dietary dependence on marine protein in the associated community and across the Mollucas Province, and the short time period since ASGM operations commenced in this region, the results warrant urgent further investigation, risk mitigation, and community education. Copyright © 2016 Elsevier Inc. All rights reserved.
Kramers-Kronig receiver operable without digital upsampling.
Bo, Tianwai; Kim, Hoon
2018-05-28
The Kramers-Kronig (KK) receiver is capable of retrieving the phase information of optical single-sideband (SSB) signal from the optical intensity when the optical signal satisfies the minimum phase condition. Thus, it is possible to direct-detect the optical SSB signal without suffering from the signal-signal beat interference and linear transmission impairments. However, due to the spectral broadening induced by nonlinear operations in the conventional KK algorithm, it is necessary to employ the digital upsampling at the beginning of the digital signal processing (DSP). The increased number of samples at the DSP would hinder the real-time implementation of this attractive receiver. Hence, we propose a new DSP algorithm for KK receiver operable at 2 samples per symbol. We adopt a couple of mathematical approximations to avoid the use of nonlinear operations such as logarithm and exponential functions. By using the proposed algorithm, we demonstrate the transmission of 112-Gb/s SSB orthogonal frequency-division-multiplexed signal over an 80-km fiber link. The results show that the proposed algorithm operating at 2 samples per symbol exhibits similar performance to the conventional KK one operating at 6 samples per symbol. We also present the error analysis of the proposed algorithm for KK receiver in comparison with the conventional one.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibarra-Sierra, V.G.; Sandoval-Santana, J.C.; Cardoso, J.L.
We discuss the one-dimensional, time-dependent general quadratic Hamiltonian and the bi-dimensional charged particle in time-dependent electromagnetic fields through the Lie algebraic approach. Such method consists in finding a set of generators that form a closed Lie algebra in terms of which it is possible to express a quantum Hamiltonian and therefore the evolution operator. The evolution operator is then the starting point to obtain the propagator as well as the explicit form of the Heisenberg picture position and momentum operators. First, the set of generators forming a closed Lie algebra is identified for the general quadratic Hamiltonian. This algebra ismore » later extended to study the Hamiltonian of a charged particle in electromagnetic fields exploiting the similarities between the terms of these two Hamiltonians. These results are applied to the solution of five different examples: the linear potential which is used to introduce the Lie algebraic method, a radio frequency ion trap, a Kanai–Caldirola-like forced harmonic oscillator, a charged particle in a time dependent magnetic field, and a charged particle in constant magnetic field and oscillating electric field. In particular we present exact analytical expressions that are fitting for the study of a rotating quadrupole field ion trap and magneto-transport in two-dimensional semiconductor heterostructures illuminated by microwave radiation. In these examples we show that this powerful method is suitable to treat quadratic Hamiltonians with time dependent coefficients quite efficiently yielding closed analytical expressions for the propagator and the Heisenberg picture position and momentum operators. -- Highlights: •We deal with the general quadratic Hamiltonian and a particle in electromagnetic fields. •The evolution operator is worked out through the Lie algebraic approach. •We also obtain the propagator and Heisenberg picture position and momentum operators. •Analytical expressions for a rotating quadrupole field ion trap are presented. •Exact solutions for magneto-transport in variable electromagnetic fields are shown.« less
National and State Treatment Need and Capacity for Opioid Agonist Medication-Assisted Treatment
Campopiano, Melinda; Baldwin, Grant; McCance-Katz, Elinore
2015-01-01
Objectives. We estimated national and state trends in opioid agonist medication-assisted treatment (OA-MAT) need and capacity to identify gaps and inform policy decisions. Methods. We generated national and state rates of past-year opioid abuse or dependence, maximum potential buprenorphine treatment capacity, number of patients receiving methadone from opioid treatment programs (OTPs), and the percentage of OTPs operating at 80% capacity or more using Substance Abuse and Mental Health Services Administration data. Results. Nationally, in 2012, the rate of opioid abuse or dependence was 891.8 per 100 000 people aged 12 years or older compared with national rates of maximum potential buprenorphine treatment capacity and patients receiving methadone in OTPs of, respectively, 420.3 and 119.9. Among states and the District of Columbia, 96% had opioid abuse or dependence rates higher than their buprenorphine treatment capacity rates; 37% had a gap of at least 5 per 1000 people. Thirty-eight states (77.6%) reported at least 75% of their OTPs were operating at 80% capacity or more. Conclusions. Significant gaps between treatment need and capacity exist at the state and national levels. Strategies to increase the number of OA-MAT providers are needed. PMID:26066931
A comparison of two methods of infiltration in breast reduction surgery.
Armour, A D; Rotenberg, B W; Brown, M H
2001-08-01
The superwet technique has been shown in previous studies to dramatically reduce blood loss in breast reduction surgery, compared with standard infiltration. A retrospective chart review of 303 consecutive patients undergoing bilateral breast reduction surgery was undertaken to demonstrate additional differences in complication rate, operative time, or sponge use in the operating room. In this series, 132 consecutive patients received standard infiltration along incision lines (25 cc per breast of 1:100,000 epinephrine), and 171 patients received superwet infiltration with 240 cc per breast of 1:1,000,000 epinephrine. The average operative time was significantly reduced in the superwet group, from 78.5 minutes to 70.7 minutes (p < 0.01 level). The average number of sponges used intraoperatively was also decreased significantly (p < 0.01), from 26 to 20 sponges. Complication rates were equally low in both groups, demonstrating the safety of the superwet technique. In addition to limiting blood loss, the superwet infiltration effectively reduces operative time and sponge use without increasing complications in breast reduction surgery.
NASA Technical Reports Server (NTRS)
Wang, Charles C.; Sue, Miles K.; Manshadi, Farzin; Kinman, Peter
2005-01-01
This paper will first describe the characteristics of interference from a typical EESS satellite, including the intensity, frequency and duration of such interference. The paper will then discuss the DSN interference susceptibility, including the various components in the receiving systems that are susceptible to interference and the recovery time after a strong interference. Finally, the paper will discuss the impact of interference on science data and missions operations.
The role of skin biopsy in differentiating small-fiber neuropathy from ganglionopathy.
Provitera, V; Gibbons, C H; Wendelschafer-Crabb, G; Donadio, V; Vitale, D F; Loavenbruck, A; Stancanelli, A; Caporaso, G; Liguori, R; Wang, N; Santoro, L; Kennedy, W R; Nolano, M
2018-06-01
We aimed to test the clinical utility of the leg:thigh intraepidermal nerve-fiber (IENF) density ratio as a parameter to discriminate between length-dependent small-fiber neuropathy (SFN) and small-fiber sensory ganglionopathy (SFSG) in subjects with signs and symptoms of small-fiber pathology. We retrospectively evaluated thigh and leg IENF density in 314 subjects with small-fiber pathology (173 with distal symmetrical length-dependent SFN and 141 with non-length-dependent SFSG). A group of 288 healthy subjects was included as a control group. The leg:thigh IENF density ratio was calculated for all subjects. We used receiver operating characteristic curve analyses to assess the ability of this parameter to discriminate between length-dependent SFN and SFSG, and the decision curve analysis to estimate its net clinical benefit. In patients with neuropathy, the mean IENF density was 14.8 ± 6.8/mm at the thigh (14.0 ± 6.9/mm in length-dependent SFN and 15.9 ± 6.7/mm in patients with SFSG) and 7.5 ± 4.5/mm at the distal leg (5.4 ± 3.2/mm in patients with length-dependent SFN and 10.1 ± 4.6/mm in patients with SFSG). The leg:thigh IENF density ratio was significantly (P < 0.01) lower in patients with length-dependent SFN (0.44 ± 0.23) compared with patients with SFSG (0.68 ± 0.28). The area under the curve of the receiver operating characteristic analysis to discriminate between patients with length-dependent SFN and SFSG was 0.79. The decision curve analysis demonstrated the clinical utility of this parameter. The leg:thigh IENF ratio represents a valuable tool in the differential diagnosis between SFSG and length-dependent SFN. © 2018 EAN.
Time-dependent effects of cortisol on the contextualization of emotional memories.
van Ast, Vanessa A; Cornelisse, Sandra; Meeter, Martijn; Joëls, Marian; Kindt, Merel
2013-12-01
The inability to store fearful memories into their original encoding context is considered to be an important vulnerability factor for the development of anxiety disorders like posttraumatic stress disorder. Altered memory contextualization most likely involves effects of the stress hormone cortisol, acting via receptors located in the memory neurocircuitry. Cortisol via these receptors induces rapid nongenomic effects followed by slower genomic effects, which are thought to modulate cognitive function in opposite, complementary ways. Here, we targeted these time-dependent effects of cortisol during memory encoding and tested subsequent contextualization of emotional and neutral memories. In a double-blind, placebo-controlled design, 64 men were randomly assigned to one of three groups: 1) received 10 mg hydrocortisone 30 minutes (rapid cortisol effects) before a memory encoding task; 2) received 10 mg hydrocortisone 210 minutes (slow cortisol) before a memory encoding task; or 3) received placebo at both times. During encoding, participants were presented with neutral and emotional words in unique background pictures. Approximately 24 hours later, context dependency of their memories was assessed. Recognition data revealed that cortisol's rapid effects impair emotional memory contextualization, while cortisol's slow effects enhance it. Neutral memory contextualization remained unaltered by cortisol, irrespective of the timing of the drug. This study shows distinct time-dependent effects of cortisol on the contextualization of specifically emotional memories. The results suggest that rapid effects of cortisol may lead to impaired emotional memory contextualization, while slow effects of cortisol may confer protection against emotional memory generalization. © 2013 Society of Biological Psychiatry.
Rapoport, Yuna; Wayman, Laura L; Chomsky, Amy S
2017-06-07
A growing proportion of veterans treated at the Veterans Health Administration (VA) have a history of post-traumatic-stress-disorder (PTSD), and there exists a higher rate of PTSD amongst veterans than the general population. The purpose of this study is to determine the correlation between PTSD and intra-operative analgesia, intra-operative time, and anesthesia type for cataract surgery in a veteran population. Secondary objectives are to determine if patient age, and first or second eye surgery affect intra-operative pain control or are correlated with type of anesthesia modality. A retrospective study of 330 cataract surgeries performed by resident physicians between January and September 2012 at the Veterans Affairs Medical Center Tennessee Valley Healthcare System, Nashville and Murfreesboro Campuses was completed. Three hundred and thirty veteran patients were selected if their cataract surgery was performed between January and September 2012. Combined cases were excluded. The primary outcome evaluated was intra-operative analgesia. Secondary outcomes included history of post-traumatic-stress-disorder, anesthesia type, first or second eye, pain control, intra-operative heart rate and blood pressure, age, and case complexity. Data was analyzed using an unpaired two-sample Welch's t-test assuming unequal variance and Z test of comparison of proportions. Patients with post-traumatic-stress-disorder reported higher pain scores, had longer operative times, and were more likely to have received a retrobulbar block. Operative time was not associated with an increased pain score, irrespective of anesthesia type, when controlled for PTSD. Complex cases had longer operative times, more sedation, and higher pain scores. P < 0.05 was used consistently. Post-traumatic stress disorder and anxiety are more prevalent in the veteran population. Our data suggests that a history of post-traumatic-stress-disorder was correlated with higher pain scores, longer operative times, and with having received a retrobulbar block. Patients without a history of PTSD were more likely to have received topical anesthesia with or without sedation. The veteran population requires more sedation to allay anxiety and perceptions of discomfort, which may account for longer surgical times. The veteran population is a special population and it is important to investigate how PTSD in the veteran population affects intra-operative analgesia.
Shiraki, Tatsuya; Iida, Osamu; Takahara, Mitsuyoshi; Okamoto, Shin; Kitano, Ikurou; Tsuji, Yoshihiko; Terashi, Hiroto; Uematsu, Masaaki
2014-08-01
The latest guideline points to life expectancy of <2 years as the main determinant in revascularization modality selection (bypass surgery [BSX] or endovascular therapy [EVT]) in patients with critical limb ischemia (CLI). This study examined predictors and a predictive scoring model of 2-year mortality after revascularization. We performed Cox proportional hazards regression analysis of data in a retrospective database, the Bypass and Endovascular therapy Against Critical limb ischemia from Hyogo (BEACH) registry, of 459 consecutive CLI patients who underwent revascularization (396 EVT and 63 BSX cases between January 2007 and December 2011) to determine predictors of 2-year mortality. The predictive performance of the score was assessed with the area under the time-dependent receiver operating characteristic curve. Of 459 CLI patients (mean age, 72 ± 10 years; 64% male; 49% nonambulatory status, 68% diabetes mellitus, 47% on regular dialysis, and 18% rest pain and 82% tissue loss as treatment indication), 84 died within 2 years after revascularization. In a multivariate model, age >75 years (hazard ratio [HR], 1.77; 95% confidence interval [CI], 1.10-2.85), nonambulatory status (HR, 5.32; 95% CI, 2.96-9.56), regular dialysis (HR, 1.90; 95% CI, 1.10-3.26), and ejection fraction <50% (HR, 2.49; 95% CI, 1.48-4.20) were independent predictors of 2-year mortality. The area under the time-dependent receiver operating characteristic curve for the developed predictive BEACH score was 0.81 (95% CI, 0.76-0.86). Predictors of 2-year mortality after EVT or BSX in CLI patients included age >75 years, nonambulatory status, regular dialysis, and ejection fraction <50%. The BEACH score derived from these predictors allows risk stratification of CLI patients undergoing revascularization. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Predictive modeling of addiction lapses in a mobile health application.
Chih, Ming-Yuan; Patton, Timothy; McTavish, Fiona M; Isham, Andrew J; Judkins-Fisher, Chris L; Atwood, Amy K; Gustafson, David H
2014-01-01
The chronically relapsing nature of alcoholism leads to substantial personal, family, and societal costs. Addiction-comprehensive health enhancement support system (A-CHESS) is a smartphone application that aims to reduce relapse. To offer targeted support to patients who are at risk of lapses within the coming week, a Bayesian network model to predict such events was constructed using responses on 2,934 weekly surveys (called the Weekly Check-in) from 152 alcohol-dependent individuals who recently completed residential treatment. The Weekly Check-in is a self-monitoring service, provided in A-CHESS, to track patients' recovery progress. The model showed good predictability, with the area under receiver operating characteristic curve of 0.829 in the 10-fold cross-validation and 0.912 in the external validation. The sensitivity/specificity table assists the tradeoff decisions necessary to apply the model in practice. This study moves us closer to the goal of providing lapse prediction so that patients might receive more targeted and timely support. © 2013.
NASA Astrophysics Data System (ADS)
Barthelmy, Scott
2015-04-01
The Gamma-ray Coordinates Network / Transient Astronomy Network (GCN/TAN) is your one-stop shopping place for all transient astronomy. It collects nearly all the astrophysical transients from the missions (space-based and ground-based), puts them into a standard format, and distributes them to whomever wishes to receive them. This is all done autonomously (completely autonomous within GCN/TAN, and almost always autonomously within the producer end of operations). This automation means minimal time delays (<0.1 sec within GCN for socket-based distribution methods, and up to 30 sec for email-based which is dependant on the internet email protocol and the number of hops (both of which are out of the control of GCN/TAN). A status report on the current set of sources of transient information, plus recently-added and soon-to-be-added source will be given. Also, a standing request for GCN/TAN to incorporate your transient data stream; plus instruction for customers to receive GCN/TAAN Notice and Circular information.
Predictive Modeling of Addiction Lapses in a Mobile Health Application
Chih, Ming-Yuan; Patton, Timothy; McTavish, Fiona M.; Isham, Andrew; Judkins-Fisher, Chris L.; Atwood, Amy K.; Gustafson, David H.
2013-01-01
The chronically relapsing nature of alcoholism leads to substantial personal, family, and societal costs. Addiction-Comprehensive Health Enhancement Support System (A-CHESS) is a smartphone application that aims to reduce relapse. To offer targeted support to patients who are at risk of lapses within the coming week, a Bayesian network model to predict such events was constructed using responses on 2,934 weekly surveys (called the Weekly Check-in) from 152 alcohol-dependent individuals who recently completed residential treatment. The Weekly Check-in is a self-monitoring service, provided in A-CHESS, to track patients’ recovery progress. The model showed good predictability, with the area under receiver operating characteristic curve of 0.829 in the 10-fold cross-validation and 0.912 in the external validation. The sensitivity/specificity table assists the tradeoff decisions necessary to apply the model in practice. This study moves us closer to the goal of providing lapse prediction so that patients might receive more targeted and timely support. PMID:24035143
Development of an Ultra-Wideband Receiver for the North America Array
NASA Astrophysics Data System (ADS)
Velazco, J. E.; Soriano, M.; Hoppe, D.; Russell, D.; D'Addario, L.; Long, E.; Bowen, J.; Samoska, L.; Lazio, J.
2016-11-01
The North America Array (NAA) is a concept for a radio astronomical interferometric array operating in the 1.2 GHz to 116 GHz frequency range. It has been designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage beyond the current Karl G. Jansky Very Large Array (VLA). It will have a continuous frequency coverage of 1.2 GHz to 50 GHz and 70 to 116 GHz, and a total aperture 10 times more sensitive than the VLA (and 25 times more sensitive than a 34-m-diameter antenna of the Deep Space Network [DSN]). One of the key goals for the NAA is to reduce the operating costs without sacrificing performance. We are designing an ultra-wideband receiver package designed to operate across the 8 to 48 GHz frequency range in contrast to the current VLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs. To minimize implementation, operational, and maintenance costs, we are developing a receiver that is compact, simple to assemble, and that consumes less power. The objective of this work is to develop a prototype integrated feed-receiver package with a sensitivity performance comparable to current narrower-band systems on radio telescopes and the DSN, but with a design that meets the requirement of low long-term operational costs. The ultra-wideband receiver package consists of a feedhorn, low-noise amplifier (LNA), and downconverters to analog intermediate frequencies. Both the feedhorn and the LNA are cryogenically cooled. Key features of this design are a quad-ridge feedhorn with dielectric loading and a cryogenic receiver with a noise temperature of no more than 30°K at the low end of the band. In this article, we report on the status of this receiver package development, including the feed design and LNA implementation. We present simulation studies of the feed horn carried out to optimize illumination efficiencies across the band of interest. In addition, we show experimental results of low-noise 70-nm gallium arsenide, metamorphic high-electron-mobility-transistor (HEMT) amplifier testing performed across the 1 to 18 GHz frequency range. Also presented are 8 to 48 GHz simulation results for 35-nm indium phosphide HEMT amplifiers.
Waveform synthesis for imaging and ranging applications
Doerry, Armin W.; Dudley, Peter A.; Dubert, Dale F.; Tise, Bertice L.
2004-12-07
Frequency dependent corrections are provided for quadrature imbalance and Local Oscillator (LO) feed-through. An operational procedure filters imbalance and LO feed-through effects without prior calibration or equalization. Waveform generation can be adjusted/corrected in a synthetic aperture radar system (SAR), where a rolling phase shift is applied to the SAR's QDWS signal where it is demodulated in a receiver; unwanted energies, such as LO feed-through and/or imbalance energy, are separated from a desired signal in Doppler; the separated energy is filtered from the receiver leaving the desired signal; and the separated energy in the receiver is measured to determine the degree of imbalance that is represented by it. Calibration methods can also be implemented into synthesis. The degree of LO feed-through and imbalance can be used to determine calibration values that can then be provided as compensation for frequency dependent errors in components, such as the QDWS and SSB mixer, affecting quadrature signal quality.
Waveform Synthesizer For Imaging And Ranging Applications
Dubbert, Dale F.; Dudley, Peter A.; Doerry, Armin W.; Tise, Bertice L.
2004-12-28
Frequency dependent corrections are provided for Local Oscillator (LO) feed-through. An operational procedure filters LO feed-through effects without prior calibration or equalization. Waveform generation can be adjusted/corrected in a synthetic aperture radar system (SAR), where a rolling phase shift is applied to the SAR's QDWS signal where it is demodulated in a receiver, unwanted energies, such as LO feed-through energy, are separated from a desired signal in Doppler; the separated energy is filtered from the receiver leaving the desired signal; and the separated energy in the receiver is measured to determine the degree of imbalance that is represented by it. Calibration methods can also be implemented into synthesis. The degree of LO feed-through can be used to determine calibration values that can then be provided as compensation for frequency dependent errors in components, such as the QDWS and SSB mixer, affecting quadrature signal quality.
Ionospheric corrections to precise time transfer using GPS
NASA Technical Reports Server (NTRS)
Snow, Robert W.; Osborne, Allen W., III; Klobuchar, John A.; Doherty, Patricia H.
1994-01-01
The free electrons in the earth's ionosphere can retard the time of reception of GPS signals received at a ground station, compared to their time in free space, by many tens of nanoseconds, thus limiting the accuracy of time transfer by GPS. The amount of the ionospheric time delay is proportional to the total number of electrons encountered by the wave on its path from each GPS satellite to a receiver. This integrated number of electrons is called Total Electron Content, or TEC. Dual frequency GPS receivers designed by Allen Osborne Associates, Inc. (AOA) directly measure both the ionospheric differential group delay and the differential carrier phase advance for the two GPS frequencies and derive from this the TEC between the receiver and each GPS satellite in track. The group delay information is mainly used to provide an absolute calibration to the relative differential carrier phase, which is an extremely precise measure of relative TEC. The AOA Mini-Rogue ICS-4Z and the AOA TurboRogue ICS-4000Z receivers normally operate using the GPS P code, when available, and switch to cross-correlation signal processing when the GPS satellites are in the Anti-Spoofing (A-S) mode and the P code is encrypted. An AOA ICS-Z receiver has been operated continuously for over a year at Hanscom AFB, MA to determine the statistics of the variability of the TEC parameter using signals from up to four different directions simultaneously. The 4-channel ICS-4Z and the 8-channel ICS-4000Z, have proven capabilities to make precise, well calibrated, measurements of the ionosphere in several directions simultaneously. In addition to providing ionospheric corrections for precise time transfer via satellite, this dual frequency design allows full code and automatic codeless operation of both the differential group delay and differential carrier phase for numerous ionospheric experiments being conducted. Statistical results of the data collected from the ICS-4Z during the initial year of ionospheric time delay in the northeastern U.S., and initial results with the ICS-4000Z, will be presented.
Looney, Pádraig; Stevenson, Gordon N; Nicolaides, Kypros H; Plasencia, Walter; Molloholli, Malid; Natsis, Stavros; Collins, Sally L
2018-06-07
We present a new technique to fully automate the segmentation of an organ from 3D ultrasound (3D-US) volumes, using the placenta as the target organ. Image analysis tools to estimate organ volume do exist but are too time consuming and operator dependant. Fully automating the segmentation process would potentially allow the use of placental volume to screen for increased risk of pregnancy complications. The placenta was segmented from 2,393 first trimester 3D-US volumes using a semiautomated technique. This was quality controlled by three operators to produce the "ground-truth" data set. A fully convolutional neural network (OxNNet) was trained using this ground-truth data set to automatically segment the placenta. OxNNet delivered state-of-the-art automatic segmentation. The effect of training set size on the performance of OxNNet demonstrated the need for large data sets. The clinical utility of placental volume was tested by looking at predictions of small-for-gestational-age babies at term. The receiver-operating characteristics curves demonstrated almost identical results between OxNNet and the ground-truth). Our results demonstrated good similarity to the ground-truth and almost identical clinical results for the prediction of SGA.
NMR transmit-receive system with short recovery time and effective isolation
NASA Astrophysics Data System (ADS)
Jurga, K.; Reynhardt, E. C.; Jurga, S.
A transmit-receive system with a short recovery time and excellent isolation has been developed. The system operates in conjunction with an ENI Model 3200L broadband amplifier and a spin-lock NMR pulse spectrometer. The system has been tested in the frequency range 5.5 to 52 MHz and seems not to generate any background noise.
NASA Astrophysics Data System (ADS)
Shaikhova, G.; Ozat, N.; Yesmakhanova, K.; Bekova, G.
2018-02-01
In this work, we present Lax pair for two-dimensional complex modified Korteweg-de Vries and Maxwell-Bloch (cmKdV-MB) system with the time-dependent coefficient. Dark and bright soliton solutions for the cmKdV-MB system with variable coefficient are received by Darboux transformation. Moreover, the determinant representation of the one-fold and two-fold Darboux transformation for the cmKdV-MB system with time-dependent coefficient is presented.
Rabanus, D; Graf, U U; Philipp, M; Ricken, O; Stutzki, J; Vowinkel, B; Wiedner, M C; Walther, C; Fischer, M; Faist, J
2009-02-02
We demonstrate for the first time the closure of an electronic phase lock loop for a continuous-wave quantum cascade laser (QCL) at 1.5 THz. The QCL is operated in a closed cycle cryo cooler. We achieved a frequency stability of better than 100 Hz, limited by the resolution bandwidth of the spectrum analyser. The PLL electronics make use of the intermediate frequency (IF) obtained from a hot electron bolometer (HEB) which is downconverted to a PLL IF of 125 MHz. The coarse selection of the longitudinal mode and the fine tuning is achieved via the bias voltage of the QCL. Within a QCL cavity mode, the free-running QCL shows frequency fluctuations of about 5 MHz, which the PLL circuit is able to control via the Stark-shift of the QCL gain material. Temperature dependent tuning is shown to be nonlinear, and of the order of -16 MHz/K. Additionally we have used the QCL as local oscillator (LO) to pump an HEB and perform, again for the first time at 1.5 THz, a heterodyne experiment, and obtain a receiver noise temperature of 1741 K.
Optical Vector Receiver Operating Near the Quantum Limit
NASA Astrophysics Data System (ADS)
Vilnrotter, V. A.; Lau, C.-W.
2005-05-01
An optical receiver concept for binary signals with performance approaching the quantum limit at low average-signal energies is developed and analyzed. A conditionally nulling receiver that reaches the quantum limit in the absence of background photons has been devised by Dolinar. However, this receiver requires ideal optical combining and complicated real-time shaping of the local field; hence, it tends to be difficult to implement at high data rates. A simpler nulling receiver that approaches the quantum limit without complex optical processing, suitable for high-rate operation, had been suggested earlier by Kennedy. Here we formulate a vector receiver concept that incorporates the Kennedy receiver with a physical beamsplitter, but it also utilizes the reflected signal component to improve signal detection. It is found that augmenting the Kennedy receiver with classical coherent detection at the auxiliary beamsplitter output, and optimally processing the vector observations, always improves on the performance of the Kennedy receiver alone, significantly so at low average-photon rates. This is precisely the region of operation where modern codes approach channel capacity. It is also shown that the addition of background radiation has little effect on the performance of the coherent receiver component, suggesting a viable approach for near-quantum-limited performance in high background environments.
Average receiving scaling of the weighted polygon Koch networks with the weight-dependent walk
NASA Astrophysics Data System (ADS)
Ye, Dandan; Dai, Meifeng; Sun, Yanqiu; Shao, Shuxiang; Xie, Qi
2016-09-01
Based on the weighted Koch networks and the self-similarity of fractals, we present a family of weighted polygon Koch networks with a weight factor r(0 < r ≤ 1) . We study the average receiving time (ART) on weight-dependent walk (i.e., the walker moves to any of its neighbors with probability proportional to the weight of edge linking them), whose key step is to calculate the sum of mean first-passage times (MFPTs) for all nodes absorpt at a hub node. We use a recursive division method to divide the weighted polygon Koch networks in order to calculate the ART scaling more conveniently. We show that the ART scaling exhibits a sublinear or linear dependence on network order. Thus, the weighted polygon Koch networks are more efficient than expended Koch networks in receiving information. Finally, compared with other previous studies' results (i.e., Koch networks, weighted Koch networks), we find out that our models are more general.
Development of a prototype real-time automated filter for operational deep space navigation
NASA Technical Reports Server (NTRS)
Masters, W. C.; Pollmeier, V. M.
1994-01-01
Operational deep space navigation has been in the past, and is currently, performed using systems whose architecture requires constant human supervision and intervention. A prototype for a system which allows relatively automated processing of radio metric data received in near real-time from NASA's Deep Space Network (DSN) without any redesign of the existing operational data flow has been developed. This system can allow for more rapid response as well as much reduced staffing to support mission navigation operations.
Changes in brain activation in breast cancer patients depend on cognitive domain and treatment type
Menning, Sanne; de Ruiter, Michiel B.; Veltman, Dick J.; Boogerd, Willem; Oldenburg, Hester S. A.; Reneman, Liesbeth
2017-01-01
Background Cognitive problems in breast cancer patients are common after systemic treatment, particularly chemotherapy. An increasing number of fMRI studies show altered brain activation in breast cancer patients after treatment, suggestive of neurotoxicity. Previous prospective fMRI studies administered a single cognitive task. The current study employed two task paradigms to evaluate whether treatment-induced changes depend on the probed cognitive domain. Methods Participants were breast cancer patients scheduled to receive systemic treatment (anthracycline-based chemotherapy +/- endocrine treatment, n = 28), or no systemic treatment (n = 24) and no-cancer controls (n = 31). Assessment took place before adjuvant treatment and six months after chemotherapy, or at similar intervals. Blood oxygen level dependent (BOLD) activation and performance were measured during an executive functioning task and an episodic memory task. Group-by-time interactions were analyzed using a flexible factorial design. Results Task performance did not differ between patient groups and did not change over time. Breast cancer patients who received systemic treatment, however, showed increased parietal activation compared to baseline with increasing executive functioning task load compared to breast cancer patients who did not receive systemic treatment. This hyperactivation was accompanied by worse physical functioning, higher levels of fatigue and more cognitive complaints. In contrast, in breast cancer patients who did not receive systemic treatment, parietal activation normalized over time compared to the other two groups. Conclusions Parietal hyperactivation after systemic treatment in the context of stable levels of executive task performance is compatible with a compensatory processing account of hyperactivation or maintain adequate performance levels. This over-recruitment of brain regions depends on the probed cognitive domain and may represent a response to decreased neural integrity after systemic treatment. Overall these results suggest different neurobehavioral trajectories in breast cancer patients depending on treatment type. PMID:28267750
Changes in brain activation in breast cancer patients depend on cognitive domain and treatment type.
Menning, Sanne; de Ruiter, Michiel B; Veltman, Dick J; Boogerd, Willem; Oldenburg, Hester S A; Reneman, Liesbeth; Schagen, Sanne B
2017-01-01
Cognitive problems in breast cancer patients are common after systemic treatment, particularly chemotherapy. An increasing number of fMRI studies show altered brain activation in breast cancer patients after treatment, suggestive of neurotoxicity. Previous prospective fMRI studies administered a single cognitive task. The current study employed two task paradigms to evaluate whether treatment-induced changes depend on the probed cognitive domain. Participants were breast cancer patients scheduled to receive systemic treatment (anthracycline-based chemotherapy +/- endocrine treatment, n = 28), or no systemic treatment (n = 24) and no-cancer controls (n = 31). Assessment took place before adjuvant treatment and six months after chemotherapy, or at similar intervals. Blood oxygen level dependent (BOLD) activation and performance were measured during an executive functioning task and an episodic memory task. Group-by-time interactions were analyzed using a flexible factorial design. Task performance did not differ between patient groups and did not change over time. Breast cancer patients who received systemic treatment, however, showed increased parietal activation compared to baseline with increasing executive functioning task load compared to breast cancer patients who did not receive systemic treatment. This hyperactivation was accompanied by worse physical functioning, higher levels of fatigue and more cognitive complaints. In contrast, in breast cancer patients who did not receive systemic treatment, parietal activation normalized over time compared to the other two groups. Parietal hyperactivation after systemic treatment in the context of stable levels of executive task performance is compatible with a compensatory processing account of hyperactivation or maintain adequate performance levels. This over-recruitment of brain regions depends on the probed cognitive domain and may represent a response to decreased neural integrity after systemic treatment. Overall these results suggest different neurobehavioral trajectories in breast cancer patients depending on treatment type.
Determining collective barrier operation skew in a parallel computer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faraj, Daniel A.
2015-11-24
Determining collective barrier operation skew in a parallel computer that includes a number of compute nodes organized into an operational group includes: for each of the nodes until each node has been selected as a delayed node: selecting one of the nodes as a delayed node; entering, by each node other than the delayed node, a collective barrier operation; entering, after a delay by the delayed node, the collective barrier operation; receiving an exit signal from a root of the collective barrier operation; and measuring, for the delayed node, a barrier completion time. The barrier operation skew is calculated by:more » identifying, from the compute nodes' barrier completion times, a maximum barrier completion time and a minimum barrier completion time and calculating the barrier operation skew as the difference of the maximum and the minimum barrier completion time.« less
Determining collective barrier operation skew in a parallel computer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faraj, Daniel A.
Determining collective barrier operation skew in a parallel computer that includes a number of compute nodes organized into an operational group includes: for each of the nodes until each node has been selected as a delayed node: selecting one of the nodes as a delayed node; entering, by each node other than the delayed node, a collective barrier operation; entering, after a delay by the delayed node, the collective barrier operation; receiving an exit signal from a root of the collective barrier operation; and measuring, for the delayed node, a barrier completion time. The barrier operation skew is calculated by:more » identifying, from the compute nodes' barrier completion times, a maximum barrier completion time and a minimum barrier completion time and calculating the barrier operation skew as the difference of the maximum and the minimum barrier completion time.« less
Time synchronization via lunar radar.
NASA Technical Reports Server (NTRS)
Higa, W. H.
1972-01-01
The advent of round-trip radar measurements has permitted the determination of the ranges to the nearby planets with greater precision than was previously possible. When the distances to the planets are known with high precision, the propagation delay for electromagnetic waves reflected by the planets may be calculated and used to synchronize remotely located clocks. Details basic to the operation of a lunar radar indicate a capability for clock synchronization to plus or minus 20 microsec. One of the design goals for this system was to achieve a simple semiautomatic receiver for remotely located tracking stations. The lunar radar system is in operational use for deep space tracking at Jet Propulsion Laboratory and synchronizes five world-wide tracking stations with a master clock at Goldstone, Calif. Computers are programmed to correct the Goldstone transmissions for transit time delay and Doppler shifts so as to be received on time at the tracking stations; this dictates that only one station can be synchronized at a given time period and that the moon must be simultaneously visible to both the transmitter and receiver for a minimum time of 10 min.-
Ito, Hiroaki; Iida, Mitsuo; Matsumoto, Takayuki; Suzuki, Yasuo; Sasaki, Hidetaka; Yoshida, Toyomitsu; Takano, Yuichi; Hibi, Toshifumi
2010-01-01
Background: Mesalamine is the first-line drug for the treatment of ulcerative colitis (UC). We directly compared the efficacy and safety of two mesalamine formulations for the induction of remission in patients with UC. Methods: In a multicenter, double-blind, randomized study, 229 patients with mild-to-moderate active UC were assigned to 4 groups: 66 and 65 received a pH-dependent release formulation of 2.4 g/day (pH-2.4 g) or 3.6 g/day (pH-3.6 g), respectively; 65 received a time-dependent release formulation of 2.25 g/day (Time-2.25 g), and 33 received placebo (Placebo). The drugs were administered three times daily for eight weeks. The primary endpoint was a decrease in the UC disease activity index (UC-DAI). Results: In the full analysis set (n = 225) the decrease in UC-DAI in each group was 1.5 in pH-2.4 g, 2.9 in pH-3.6 g, 1.3 in Time-2.25 g and 0.3 in Placebo, respectively. These results demonstrate the superiority of pH-3.6 g over Time-2.25 g (P = 0.003) and the noninferiority of pH-2.4 g to Time-2.25 g. Among the patients with proctitis-type UC, a significant decrease in UC-DAI was observed in pH-2.4 g and pH-3.6 g as compared to Placebo, but not in Time-2.25 g. No differences were observed in the safety profiles. Conclusions: Higher dose of the pH-dependent release formulation was more effective for induction of remission in patients with mild-to-moderate active UC. Additionally, the pH-dependent release formulation was preferable to the time-dependent release formulation for patients with proctitis-type UC (UMIN Clinical Trials Registry, no. C000000288). (Inflamm Bowel Dis 2010) PMID:20049950
Geospace monitoring for space weather research and operation
NASA Astrophysics Data System (ADS)
Nagatsuma, Tsutomu
2017-10-01
Geospace, a space surrounding the Earth, is one of the key area for space weather. Because geospace environment dynamically varies depending on the solar wind conditions. Many kinds of space assets are operating in geospace for practical purposes. Anomalies of space assets are sometimes happened because of space weather disturbances in geospace. Therefore, monitoring and forecasting of geospace environment is very important tasks for NICT's space weather research and development. To monitor and to improve forecasting model, fluxgate magnetometers and HF radars are operated by our laboratory, and its data are used for our research work, too. We also operate real-time data acquisition system for satellite data, such as DSCOVR, STEREO, and routinely received high energy particle data from Himawari-8. Based on these data, we are monitoring current condition of geomagnetic disturbances, and that of radiation belt. Using these data, we have developed empirical models for relativistic electron flux at GEO and inner magnetosphere. To provide userfriendly information , we are trying to develop individual spacecraft anomaly risk estimation tool based on combining models of space weather and those of spacecraft charging, Current status of geospace monitoring, forecasting, and research activities are introduced.
The impact of a large-scale power outage on hemodialysis center operations.
Abir, Mahshid; Jan, Sophia; Jubelt, Lindsay; Merchant, Raina M; Lurie, Nicole
2013-12-01
On June 29, 2012, mid-Atlantic storms resulted in a large-scale power outage affecting up to three million people across multiple (US) states. Hemodialysis centers are dependent on electricity to provide dialysis care to end-stage renal disease patients. The objective of this study was to determine how the power outage impacted operations in a sample of hemodialysis centers in the impacted regions. The sample consisted of all hemodialysis centers located in the District of Columbia and a total of five counties with the largest power losses in West Virginia, Virginia, and Maryland. A semi-structured interview guide was developed, and the charge nurse or supervisor in each facility was interviewed. The survey questions addressed whether their centers lost power, if so, for how long, where their patients received dialysis, whether their centers had backup generators, and if so, whether they had any problems operating them, and whether their center received patients from other centers if they had power. Calls were placed to 90 dialysis centers in the sampled areas and a 90% response rate was achieved. Overall, hemodialysis operations at approximately 30% (n = 24) of the centers queried were impacted by the power outage. Of the 36 centers that lost power, 31% (n = 11) referred their patients to other dialysis centers, 22% (n = 8) accommodated their patients during a later shift or on a different day; the rest of the centers either experienced brief power outages that did not affect operations or experienced a power outage on days that the center is usually closed. Some centers in the study cohort reported receiving patients from other centers for dialysis 33% (n = 27). Thirty-two percent (n = 26) of the centers queried had backup generators on site. Eleven percent (n = 4) of the centers experiencing power outages reported that backup generators were brought in by their parent companies. Comprehensive emergency planning for dialysis centers should include provisions for having backup generators on site, having plans in place for the timely delivery of a generator during a power outage, or having predesignated backup dialysis centers for patients to receive dialysis during emergencies. Most dialysis centers surveyed in this study were able to sustain continuity of care by implementing such pre-existing emergency plans.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... Extension of Existing Information Collection; Hoist Operators' Physical Fitness AGENCY: Mine Safety and... fitness. DATES: All comments must be received by midnight Eastern Standard Time on March 21, 2011... 56.19057 and 57.19057 require the annual examination and certification of hoist operators' fitness by...
NASA Technical Reports Server (NTRS)
Wyss, R. A.; Karasik, B. S.; McGrath, W. R.; Bumble, B.; LeDuc, H.
1999-01-01
Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.
The performance of Geiger mode avalanche photo-diodes in free space laser communication links
NASA Astrophysics Data System (ADS)
Farrell, Thomas C.
2018-05-01
Geiger mode avalanche photo-diode (APD) arrays, when used as detectors in laser communication (lasercom) receivers, promise better performance at lower signal levels than APDs operated in the linear mode. In this paper, we describe the basic operation of the Geiger mode APD array as a lasercom detector, concentrating on aspects relevant to the link design engineer (rather than, for example, describing the details of the physics of the basic device operation itself). Equations are developed that describe the effects of defocus and hold-off time on the relation between the number of photons detected by the array and the output of photo-electron counts. We show how to incorporate these equations into a link budget. The resulting predictions are validated by comparison against simulation results. Finally, we compare the performance of linear mode APD based receivers and Geiger mode APD array based receivers. Results show the Geiger mode receivers yield better performance, in terms of probability of bit error, at lower signal levels, except on links where there is an exceptionally large amount of background noise. Under those conditions, not surprisingly, the hold-off time degrades performance.
Vaze, Dhananjay; Samujh, Ram; Narasimha Rao, Katragadda Lakshmi
2014-01-01
Different studies underline the use of pre-operative antibiotic prophylaxis in clean surgeries like herniotomy and inguinal orchiopexy. But, the meta-analyses do not recommend nor discard the use of prophylactic pre-operative antibiotics. The scarcity of controlled clinical trials in paediatric population further vitiates the matter. This study assessed the difference in the rate of early post-operative wound infection cases in children who received single dose of pre-operative antibiotics and children who did not receive antibiotics after inguinal herniotomy and orchiopexy. This randomised prospective study was conducted in Paediatric Surgery department of PGIMER Chandigarh. Out of 251 patients, 112 patients were randomised to the case group and 139 were ascribed to the control group. The patients in control group were given a standard regimen of single dose of intravenous antibiotic at the time of induction followed by 3-4 days of oral antibiotic. Case group patients underwent the surgical procedure in similar manner with no antibiotic either at the time of induction or post-operatively. The incidence of surgical site infection in case group was 3.73 % and that in control group was 2.22%. The observed difference in the incidence of surgical site infection was statistically insignificant (P value = 0.7027). The overall infection rate in case and control group was 2.89%. Our preliminary experience suggests that there is no statistically significant difference in the proportion of early post-operative wound infection between the patients who received single dose of pre-operative antibiotics and the patients who received no antibiotics after inguinal herniotomy and orchiopexy. The risk of surgical site infection in paediatric heriotomies does not increase even if the child's weight is less than his/her expected weight for age.
Thresholds of physical activity associated with obesity by level of sedentary behaviour in children.
Chaput, J-P; Barnes, J D; Tremblay, M S; Fogelholm, M; Hu, G; Lambert, E V; Maher, C; Maia, J; Olds, T; Onywera, V; Sarmiento, O L; Standage, M; Tudor-Locke, C; Katzmarzyk, P T
2018-03-24
It is unknown whether moderate-to-vigorous physical activity (MVPA) thresholds for obesity should be adapted depending on level of sedentary behaviour in children. The objective of the study is to determine the MVPA thresholds that best discriminate between obese and non-obese children, by level of screen time and total sedentary time in 12 countries. This multinational, cross-sectional study included 6522 children 9-11 years of age. MVPA and sedentary time were assessed using waist-worn accelerometry, while screen time was self-reported. Obesity was defined according to the World Health Organization reference data. Receiver operating characteristic curve analyses showed that the best thresholds of MVPA to predict obesity ranged from 53.8 to 73.9 min d -1 in boys and from 41.7 to 58.7 min d -1 in girls, depending on the level of screen time. The MVPA cut-offs to predict obesity ranged from 37.9 to 75.9 min d -1 in boys and from 32.5 to 62.7 min d -1 in girls, depending on the level of sedentary behaviour. The areas under the curve ranged from 0.57 to 0.73 ('fail' to 'fair' accuracy), and most sensitivity and specificity values were below 85%, similar to MVPA alone. Country-specific analyses provided similar findings. The addition of sedentary behaviour levels to MVPA did not result in a better predictive ability to classify children as obese/non-obese compared with MVPA alone. © 2018 World Obesity Federation.
Resolving Phase Ambiguities In OQPSK
NASA Technical Reports Server (NTRS)
Nguyen, Tien M.
1991-01-01
Improved design for modulator and demodulator in offset-quaternary-phase-key-shifting (OQPSK) communication system enables receiver to resolve ambiguity in estimated phase of received signal. Features include unique-code-word modulation and detection and digital implementation of Costas loop in carrier-recovery subsystem. Enchances performance of carrier-recovery subsystem, reduces complexity of receiver by removing redundant circuits from previous design, and eliminates dependence of timing in receiver upon parallel-to-serial-conversion clock.
NASA Astrophysics Data System (ADS)
Wu, Zikai; Hou, Baoyu; Zhang, Hongjuan; Jin, Feng
2014-04-01
Deterministic network models have been attractive media for discussing dynamical processes' dependence on network structural features. On the other hand, the heterogeneity of weights affect dynamical processes taking place on networks. In this paper, we present a family of weighted expanded Koch networks based on Koch networks. They originate from a r-polygon, and each node of current generation produces m r-polygons including the node and whose weighted edges are scaled by factor w in subsequent evolutionary step. We derive closed-form expressions for average weighted shortest path length (AWSP). In large network, AWSP stays bounded with network order growing (0 < w < 1). Then, we focus on a special random walks and trapping issue on the networks. In more detail, we calculate exactly the average receiving time (ART). ART exhibits a sub-linear dependence on network order (0 < w < 1), which implies that nontrivial weighted expanded Koch networks are more efficient than un-weighted expanded Koch networks in receiving information. Besides, efficiency of receiving information at hub nodes is also dependent on parameters m and r. These findings may pave the way for controlling information transportation on general weighted networks.
Implementation Status of a Ultra-Wideband Receiver Package for the next-generation Very Large Array
NASA Astrophysics Data System (ADS)
Lazio, T. Joseph W.; Velazco, Jose; Soriano, Melissa; Hoppe, Daniel; Russell, Damon; D'Addario, Larry; Long, Ezra; Bowen, James; Samoska, Lorene; Janzen, Andrew
2017-01-01
The next-generation Very Large Array (ngVLA) is a concept for a radio astronomical interferometric array operating in the frequency range 1.2 GHz to 116 GHz and designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage above the current Very Large Array (VLA). As notional design goals, it would have a continuous frequency coverage of 1.2 GHz to 48 GHz and be 10 times more sensitive than the VLA (and 25 times more sensitive than a 34 m diameter antenna of the Deep Space Network [DSN]). One of the key goals for the ngVLA is to reduce the operating costs without sacrificing performance. We are designing an ultra-wideband receiver package designed to operate across the 8 to 48 GHz frequency range, which can be contrasted to the current VLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs, and the objective of this work is to develop a prototype integrated feed-receiver package with a sensitivity performance comparable to current narrower band systems on radio telescopes and the DSN, but with a design that meets the requirement of low long-term operational costs. The ultra-wideband receiver package consists of a feed horn, low-noise amplifier (LNA), and down-converters to analog intermediate frequencies. Key features of this design are a quad-ridge feed horn with dielectric loading and a cryogenic receiver with a noise temperature of no more than 30 K at the low end of the band. We will report on the status of this receiver package development including the feed design and LNA implementation. We will present simulation studies of the feed horn including the insertion of dielectric components for improved illumination efficiencies across the band of interest. In addition, we will show experimental results of low-noise 35nm InP HEMT amplifier testing performed across the 8-50 GHz frequency range.Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.
Akar, Serpil; Gokyigit, Birsen; Sayin, Nihat; Demirok, Ahmet; Yilmaz, Omer Faruk
2013-01-01
To evaluate the results of Faden operations on the medial rectus (MR) muscles with or without recession for the treatment of partially accommodative esotropia associated with a high accommodative convergence to accommodation (AC : A) ratio and to determine whether there was a decrease in the effects of posterior fixation over time. In this retrospective study, 108 of 473 patients who underwent surgery for partially accommodative esotropia with a high AC : A ratio received Faden operations on both MR muscles, and 365 received symmetric MR muscle recessions combined with a Faden operation. For the Faden operation, a satisfactory outcome of 76.9% at 1 month postoperation, decreased to 71.3% by the final follow-up visit (mean 4.8 years). A moderate positive correlation was observed between the increase in the postoperative near deviation and postoperative time. For the Faden operations combined with MR recession, a satisfactory outcome of 78.9% at 1 month post-operation, decreased to 78.4% by the final follow-up visit. A Faden operation of the MR muscles with or without recession is an effective surgical option for treating partially accommodative esotropia associated with a high AC : A ratio. For Faden operations of the MR muscles without recession, the effects of the posterior fixation decline over time.
Risk of ionising radiation to trainee orthopaedic surgeons.
Khan, Ishrat A; Kamalasekaran, Senthil; Fazal, M Ali
2012-02-01
We undertook this study to determine the amount of scattered radiation received by the primary surgeon, assistant and patient during dynamic hip screw fixation for proximal femoral fractures. Data was collected from fifty patients. Five registrars were included as operating surgeon and four senior house officers as assistant surgeon. Radiation was monitored by thermo luminescent dosimeters placed on the surgeon and assistant. The approximate distance of surgeon and assistant from the operative site was measured. A dosimeter on the unaffected hip of patients measured the radiation to the patient. The results show that the surgeon's dominant hand receives the highest dose of radiation and radiation exposure is dependent on the experience of the operator. Our study concludes that exposure to radiation during this procedure is well below the toxic levels; however greater awareness is needed for harmful effects of exposure to long term low dose radiation.
Method for laser drilling subterranean earth formations
Shuck, Lowell Z.
1976-08-31
Laser drilling of subterranean earth formations is efficiently accomplished by directing a collimated laser beam into a bore hole in registry with the earth formation and transversely directing the laser beam into the earth formation with a suitable reflector. In accordance with the present invention, the bore hole is highly pressurized with a gas so that as the laser beam penetrates the earth formation the high pressure gas forces the fluids resulting from the drilling operation into fissures and pores surrounding the laser-drilled bore so as to inhibit deleterious occlusion of the laser beam. Also, the laser beam may be dynamically programmed with some time dependent wave form, e.g., pulsed, to thermally shock the earth formation for forming or enlarging fluid-receiving fissures in the bore.
A causal model for longitudinal randomised trials with time-dependent non-compliance
Becque, Taeko; White, Ian R; Haggard, Mark
2015-01-01
In the presence of non-compliance, conventional analysis by intention-to-treat provides an unbiased comparison of treatment policies but typically under-estimates treatment efficacy. With all-or-nothing compliance, efficacy may be specified as the complier-average causal effect (CACE), where compliers are those who receive intervention if and only if randomised to it. We extend the CACE approach to model longitudinal data with time-dependent non-compliance, focusing on the situation in which those randomised to control may receive treatment and allowing treatment effects to vary arbitrarily over time. Defining compliance type to be the time of surgical intervention if randomised to control, so that compliers are patients who would not have received treatment at all if they had been randomised to control, we construct a causal model for the multivariate outcome conditional on compliance type and randomised arm. This model is applied to the trial of alternative regimens for glue ear treatment evaluating surgical interventions in childhood ear disease, where outcomes are measured over five time points, and receipt of surgical intervention in the control arm may occur at any time. We fit the models using Markov chain Monte Carlo methods to obtain estimates of the CACE at successive times after receiving the intervention. In this trial, over a half of those randomised to control eventually receive intervention. We find that surgery is more beneficial than control at 6months, with a small but non-significant beneficial effect at 12months. © 2015 The Authors. Statistics in Medicine Published by JohnWiley & Sons Ltd. PMID:25778798
Cader, Samária Ali; de Souza Vale, Rodrigo Gomes; Zamora, Victor Emmanuel; Costa, Claudia Henrique; Dantas, Estélio Henrique Martin
2012-01-01
The purpose of this study was to evaluate the extubation process in bed-ridden elderly intensive care patients receiving inspiratory muscle training (IMT) and identify predictors of successful weaning. Twenty-eight elderly intubated patients in an intensive care unit were randomly assigned to an experimental group (n = 14) that received conventional physiotherapy plus IMT with a Threshold IMT(®) device or to a control group (n = 14) that received only conventional physiotherapy. The experimental protocol for muscle training consisted of an initial load of 30% maximum inspiratory pressure, which was increased by 10% daily. The training was administered for 5 minutes, twice daily, 7 days a week, with supplemental oxygen from the beginning of weaning until extubation. Successful extubation was defined by the ventilation time measurement with noninvasive positive pressure. A vacuum manometer was used for measurement of maximum inspiratory pressure, and the patients' Tobin index values were measured using a ventilometer. The maximum inspiratory pressure increased significantly (by 7 cm H(2)O, 95% confidence interval [CI] 4-10), and the Tobin index decreased significantly (by 16 breaths/ min/L, 95% CI -26 to 6) in the experimental group compared with the control group. The Chi-squared distribution did not indicate a significant difference in weaning success between the groups (χ(2) = 1.47; P = 0.20). However, a comparison of noninvasive positive pressure time dependence indicated a significantly lower value for the experimental group (P = 0.0001; 95% CI 13.08-18.06). The receiver-operating characteristic curve showed an area beneath the curve of 0.877 ± 0.06 for the Tobin index and 0.845 ± 0.07 for maximum inspiratory pressure. The IMT intervention significantly increased maximum inspiratory pressure and significantly reduced the Tobin index; both measures are considered to be good extubation indices. IMT was associated with a reduction in noninvasive positive pressure time in the experimental group.
Mitigating Photon Jitter in Optical PPM Communication
NASA Technical Reports Server (NTRS)
Moision, Bruce
2008-01-01
A theoretical analysis of photon-arrival jitter in an optical pulse-position-modulation (PPM) communication channel has been performed, and now constitutes the basis of a methodology for designing receivers to compensate so that errors attributable to photon-arrival jitter would be minimized or nearly minimized. Photon-arrival jitter is an uncertainty in the estimated time of arrival of a photon relative to the boundaries of a PPM time slot. Photon-arrival jitter is attributable to two main causes: (1) receiver synchronization error [error in the receiver operation of partitioning time into PPM slots] and (2) random delay between the time of arrival of a photon at a detector and the generation, by the detector circuitry, of a pulse in response to the photon. For channels with sufficiently long time slots, photon-arrival jitter is negligible. However, as durations of PPM time slots are reduced in efforts to increase throughputs of optical PPM communication channels, photon-arrival jitter becomes a significant source of error, leading to significant degradation of performance if not taken into account in design. For the purpose of the analysis, a receiver was assumed to operate in a photon- starved regime, in which photon counts follow a Poisson distribution. The analysis included derivation of exact equations for symbol likelihoods in the presence of photon-arrival jitter. These equations describe what is well known in the art as a matched filter for a channel containing Gaussian noise. These equations would yield an optimum receiver if they could be implemented in practice. Because the exact equations may be too complex to implement in practice, approximations that would yield suboptimal receivers were also derived.
The Stability of GPS Carrier-Phase Receivers
2010-11-01
Frequency Transfer ( TWSTFT ) method [2]. For both CP and TWSTFT , accuracy in time transfer is achieved through special calibration efforts that retain...View (CV) receivers and TWSTFT equipment. Many of these geodetic receivers operate continuously within the International GNSS Service (IGS), and...with TWSTFT , GPS CV, and GPS P3. If ionosphere-free measurements are used in combination with nominally compensated tropospheric corrections, a
Del Pozo Rubio, Raúl; Escribano Sotos, Francisco; Moya Martínez, Pablo
2011-12-01
To analyze the relationship between sociodemographic and health variables (including informal care) and the healthcare service delivery assigned in the individualized care plan. An observational cross-sectional study was conducted in a representative sample of the dependent population in Cuenca (Spain) in February, 2009. Information was obtained on people with level II and III dependency. Four different logistic regression models were used to identify the factors associated with the care service delivery assigned in the individualized care plan. Independent variables consisted of age, gender, marital status, annual income, place of residence, health conditions, medical treatment, and perception of informal care. A total of 83.7% of the sample was assigned economic benefits and 15.3% were assigned services. Eighty percent of the sample received informal care in addition to dependency benefits. People who received informal care were 3239 times more likely to be assigned economic benefits than persons not receiving informal care. For the period analyzed (the first phase of the implementation of the Dependency Act), the variables associated with receiving economic benefits (versus services) were being married, having a high annual income, the place of residence (rural areas versus urban area), and receiving hygiene-dietary treatment and informal care. Copyright © 2011 SESPAS. Published by Elsevier Espana. All rights reserved.
El-Desouki, Munir M; Qasim, Syed Manzoor; BenSaleh, Mohammed S; Deen, M Jamal
2015-05-07
The demand for radio frequency (RF) transceivers operating at 2.4 GHz band has attracted considerable research interest due to the advancement in short range wireless technologies. The performance of RF transceivers depends heavily on the transmitter and receiver front-ends. The receiver front-end is comprised of a low-noise amplifier (LNA) and a downconversion mixer. There are very few designs that focus on connecting the single-ended output LNA to a double-balanced mixer without the use of on-chip transformer, also known as a balun. The objective of designing such a receiver front-end is to achieve high integration and low power consumption. To meet these requirements, we present the design of fully-integrated 2.4 GHz receiver front-end, consisting of a narrow-band LNA and a double balanced mixer without using a balun. Here, the single-ended RF output signal of the LNA is translated into differential signal using an NMOS-PMOS (n-channel metal-oxide-semiconductor, p-channel metal-oxide-semiconductor) transistor differential pair instead of the conventional NMOS-NMOS transistor configuration, for the RF amplification stage of the double-balanced mixer. The proposed receiver circuit fabricated using TSMC 0.18 µm CMOS technology operates at 2.4 GHz and produces an output signal at 300 MHz. The fabricated receiver achieves a gain of 16.3 dB and consumes only 6.74 mW operating at 1.5 V, while utilizing 2.08 mm2 of chip area. Measurement results demonstrate the effectiveness and suitability of the proposed receiver for short-range wireless applications, such as in wireless sensor network (WSN).
Ultra-Wideband Transceiver Design and Optimization
NASA Astrophysics Data System (ADS)
Mehra, Ashutosh
The technology landscape has quickly changed over the last few years. Developments in personal area networks, IC technology, DSP processing and bio-medical devices have enabled the integration of short range communication into low cost personal health care solutions. Newer technologies and solutions are being developed to cater to the personal operating space(POS) and body area networks(BAN). Health care is driving towards using multiple sensor and therapeutic nodes inside the POS. Technology has enabled remote patient care where the patient has low cost on-body wearables that allow the patient/physician to access vital signs without the patient physically visiting the clinic. Big semiconductor giants want to move into the wearable health monitor space. Along with the developments in fitness based health wearables, there has been a lot of interest towards developing BAN devices catering to the 'mission-critical' wearables and implants. Hearing aids, EKG monitors, neurostimulators are some examples. This work explores the use of the 802.15 ulta wideband (UWB) standard for designing a radio to operate in the a wireless sensor network in the BAN. The specific application targeted is a hearing aid. However, the design in this work is capable of working in a low power low range application with the ability to have multiple data rates ranging from a few kHz to 10's of MHz. The first radio designed by Marconi using spark-gap transmitters was an impulse radio (IR). The IR UWB technology boasts of low power, low cost, high data rates, multiple channels, simultaneous networking, the ability to carry information through obstacles that more limited bandwidths cannot, and also potentially lower complexity hardware design. The inherent timing accuracy associated with the technology gives UWB transmissions immunity to multipath fading and are hence make them more suitable for a cluttered indoor environment. The key difference with the traditional narrowband transceiver is that instead of using continuous wave (CW) transmission, impulses in time are used. The timing accuracy associated with these impulses require synchronization in time, rather than synchronization in frequency for carrier-based CW systems. A complete fully integrated system is presented in thesis. This work presents a low-power noncoherent IR UWB transceiver operating at 5GHz in 0.13um CMOS. A fully-digital transmitter generates a shaped output pulse of 1GHz 3-dB bandwidth. DLLs provide a PVT-tolerant time-step resolution of 1ns over the entire symbol period and regulate the pulse generator center frequency. The transmitter outputs -31dBm (0.88pJ/pulse at 1Mpulse/s) with a dynamic (energy) efficiency of 16pJ/pulse. The transmit out pulse is FCC part 15 compliant over process voltage and temperature (PVT) variations. The transmitter is semi-compliant with IEEE 802.15.6 and IEEE 802.15.4 standards and will become completely compliant with minor modifications. The receiver presented in this work is a non-coherent energy detect IR UWB receiver. The receiver has an on-chip transformer preceding the LNA, which is followed by a super-regenerative amplifier (SRA), envelope detector, sample-and-holds, and a bank of comparators. The design is SRA based energy-detection receiver. Measured results show a receiver efficiency of 0.32nJ/bit at 20.8Mb/s and operation with inputs as low as -70dBm. The SRA based energy-detection receiver utilizes early/late detection for a two-step baseband synchronization algorithm. An integrated solution to the issue of synchronization is also proposed. The system proposed is capable of synchronization and tracking control. The system in this work utilizes early/late detection for a two-step baseband synchronization algorithm. The algorithm is implemented in Matlab and the time to synchronization is observed to be between 250micros to a few couple of ms. Measurements have also been made using the receiver and manually implementing the algorithm. This work addresses all aspects time synchronization in an IR transceiver. The initial mismatch is addressed by two methods. Beyond the initial synchronization, the system presented in this system is also capable of tracking. This would mean that once the transceiver has been synchronized, the timing generation would continue to track the phase and the frequency changes depending upon crystal drift over time or movement between the receiver and the transmitter. A test was also performed on the complete transceiver system with two radios talking to each other over a highly attenuated wired channel.
Feasibility of Active Monitoring for Plate Coupling Using ACROSS
NASA Astrophysics Data System (ADS)
Yamaoka, K.; Watanabe, T.; Ikuta, R.
2004-12-01
Detectability of temporal changes in reflected wave from the boundary of subducting plates in Tokai district with active sources are studied. Based on rock experiments the change in the intensity of reflection wave can be caused by change in coupling between subducting and overriding plates. ACROSS (Accurately-Controlled Rountine-Operated Signal System) consists of sinusoidal vibration sources and receivers is proved to provide a data of excellent signal resolution. The following technical issues should be overcome to monitor the returned signal from boundaries of subducting plates. (1) Long term operation of the source. (2) Detection of temporal change. (3) Accurate estimation of source functions and their temporal change. First two issues have already overcome. We have already succeeded a long-term operation experiment with the ACROSS system in Awaji, Japan. The operation was carried out for 15 months with only minor troubles. Continuous signal during the experiment are successfully obtained. In the experiment we developed a technique to monitor the temporal change of travel time with a resolution of several tens of microseconds. The third issue is one of the most difficult problem for practical monitoring using artificial sources. In the 15-month experiment we correct the source function using the record of seismometers that were deployed around the source We also estimate the efficiency of the reflected wave detection using ACROSS system. We use a data of seismic exploration experiment by blasts that carried out above subducting plate in Tokai district. Clear reflection from the surface of the Philippine Sea plate is observed in the waveform. Assuming that the ACROSS source is installed at the same place of the blast source, the detectability of temporal variation of reflection wave can be estimated. As we have measured the variation of signal amplitude that depends on the distance from an ACROSS source, ground noise at seismic stations (receivers) provide us the signal-to-noise ratio for the signal from ACROSS. The resolution can be estimated only by the signal-to-noise ratio. We surveyed the noise level at the place where reflection from the boundary of subducting Philippine Sea Plate can be detected. The results show that the resolution will be better than 1% in amplitude and 0.1milisecond in travel time for the stacking of one week using three-unit source and ten-elements receiver arrays.
Karaismailoğlu, Eda; Dikmen, Zeliha Günnur; Akbıyık, Filiz; Karaağaoğlu, Ahmet Ergun
2018-04-30
Background/aim: Myoglobin, cardiac troponin T, B-type natriuretic peptide (BNP), and creatine kinase isoenzyme MB (CK-MB) are frequently used biomarkers for evaluating risk of patients admitted to an emergency department with chest pain. Recently, time- dependent receiver operating characteristic (ROC) analysis has been used to evaluate the predictive power of biomarkers where disease status can change over time. We aimed to determine the best set of biomarkers that estimate cardiac death during follow-up time. We also obtained optimal cut-off values of these biomarkers, which differentiates between patients with and without risk of death. A web tool was developed to estimate time intervals in risk. Materials and methods: A total of 410 patients admitted to the emergency department with chest pain and shortness of breath were included. Cox regression analysis was used to determine an optimal set of biomarkers that can be used for estimating cardiac death and to combine the significant biomarkers. Time-dependent ROC analysis was performed for evaluating performances of significant biomarkers and a combined biomarker during 240 h. The bootstrap method was used to compare statistical significance and the Youden index was used to determine optimal cut-off values. Results : Myoglobin and BNP were significant by multivariate Cox regression analysis. Areas under the time-dependent ROC curves of myoglobin and BNP were about 0.80 during 240 h, and that of the combined biomarker (myoglobin + BNP) increased to 0.90 during the first 180 h. Conclusion: Although myoglobin is not clinically specific to a cardiac event, in our study both myoglobin and BNP were found to be statistically significant for estimating cardiac death. Using this combined biomarker may increase the power of prediction. Our web tool can be useful for evaluating the risk status of new patients and helping clinicians in making decisions.
Non-invasive Continuous Monitoring of Cerebral Edema Using Portable Microwave Based System
NASA Astrophysics Data System (ADS)
Jiang, Yuhao; Zhao, Minji; Wang, Huiqian; Li, Guoquan
2018-01-01
A portable non-invasive head detecting system based on microwave technology was developed for evaluation of cerebral edema change inside human brain. Real-time monitoring of cerebral edema in the brain helps the clinician to assess medical condition and treatment. In this work, a microwave signal was transmitted and coupled into an open-end circular waveguide sensor, incident on a 3D printed head phantom, and reflected back to receiver. Theoretically, the operation of this instrument depends on the conductivity contrast between cerebral edema and healthy brain tissues. The efficacy of the proposed detecting system is verified using 3D printed anatomically and dielectrically realistic human head phantoms with simulated cerebral edema targets with different size. Changes in the amplitude of time domain result were shown to be induced by the expansion or decrease of the edema volume. The eventual goal of this proposed head evaluating system is use in the hospital as an effective real-time monitoring tool.
Development of efficient time-evolution method based on three-term recurrence relation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akama, Tomoko, E-mail: a.tomo---s-b-l-r@suou.waseda.jp; Kobayashi, Osamu; Nanbu, Shinkoh, E-mail: shinkoh.nanbu@sophia.ac.jp
The advantage of the real-time (RT) propagation method is a direct solution of the time-dependent Schrödinger equation which describes frequency properties as well as all dynamics of a molecular system composed of electrons and nuclei in quantum physics and chemistry. Its applications have been limited by computational feasibility, as the evaluation of the time-evolution operator is computationally demanding. In this article, a new efficient time-evolution method based on the three-term recurrence relation (3TRR) was proposed to reduce the time-consuming numerical procedure. The basic formula of this approach was derived by introducing a transformation of the operator using the arcsine function.more » Since this operator transformation causes transformation of time, we derived the relation between original and transformed time. The formula was adapted to assess the performance of the RT time-dependent Hartree-Fock (RT-TDHF) method and the time-dependent density functional theory. Compared to the commonly used fourth-order Runge-Kutta method, our new approach decreased computational time of the RT-TDHF calculation by about factor of four, showing the 3TRR formula to be an efficient time-evolution method for reducing computational cost.« less
Randomized controlled trial of Gastrografin in adhesive small bowel obstruction.
Burge, Jonathan; Abbas, Saleh M; Roadley, Graeme; Donald, Jennifer; Connolly, Andrew; Bissett, Ian P; Hill, Andrew G
2005-08-01
Several previous studies have shown that Gastrografin can be utilized to triage patients with adhesive small bowel obstruction (ASBO) to an operative or a non-operative course. Previous studies assessing the therapeutic effect of Gastrografin have been confounded by post-administration radiology alerting the physician to the treatment group of the patient. Therefore the aim of the present paper was to test the hypothesis that Gastrografin hastens the non-operative resolution of (ASBO). Patients, diagnosed with ASBO on clinical and radiological grounds, were randomized to receive Gastrografin or placebo in a double-blinded fashion. Patients did not undergo further radiological investigation. If the patient required subsequent radiological intervention or surgical intervention they were excluded from the study. End-points were passage of time to resolution of ASBO (flatus and bowel motion), length of hospital stay and complications. Forty-five patients with ASBO were randomized to receive either Gastrografin or placebo. Two patients were excluded due to protocol violations. Four patients in each group required surgery. Eighteen of the remaining patients received Gastrografin and 17 received placebo. Patients who received Gastrografin had complete resolution of their ASBO significantly earlier than placebo patients (12 vs 21 h, P = 0.009) and this translated into a median of a 1-day saving in time in hospital (3 vs 4 days, P = 0.03). Gastrografin accelerates resolution of ASBO by a specific therapeutic effect.
Tschentscher, Nadja; Hauk, Olaf
2015-01-01
Mental arithmetic is a powerful paradigm to study problem solving using neuroimaging methods. However, the evaluation of task complexity varies significantly across neuroimaging studies. Most studies have parameterized task complexity by objective features such as the number size. Only a few studies used subjective rating procedures. In fMRI, we provided evidence that strategy self-reports control better for task complexity across arithmetic conditions than objective features (Tschentscher and Hauk, 2014). Here, we analyzed the relative predictive value of self-reported strategies and objective features for performance in addition and multiplication tasks, by using a paradigm designed for neuroimaging research. We found a superiority of strategy ratings as predictor of performance above objective features. In a Principal Component Analysis on reaction times, the first component explained over 90 percent of variance and factor loadings reflected percentages of self-reported strategies well. In multiple regression analyses on reaction times, self-reported strategies performed equally well or better than objective features, depending on the operation type. A Receiver Operating Characteristic (ROC) analysis confirmed this result. Reaction times classified task complexity better when defined by individual ratings. This suggests that participants' strategy ratings are reliable predictors of arithmetic complexity and should be taken into account in neuroimaging research.
Tschentscher, Nadja; Hauk, Olaf
2015-01-01
Mental arithmetic is a powerful paradigm to study problem solving using neuroimaging methods. However, the evaluation of task complexity varies significantly across neuroimaging studies. Most studies have parameterized task complexity by objective features such as the number size. Only a few studies used subjective rating procedures. In fMRI, we provided evidence that strategy self-reports control better for task complexity across arithmetic conditions than objective features (Tschentscher and Hauk, 2014). Here, we analyzed the relative predictive value of self-reported strategies and objective features for performance in addition and multiplication tasks, by using a paradigm designed for neuroimaging research. We found a superiority of strategy ratings as predictor of performance above objective features. In a Principal Component Analysis on reaction times, the first component explained over 90 percent of variance and factor loadings reflected percentages of self-reported strategies well. In multiple regression analyses on reaction times, self-reported strategies performed equally well or better than objective features, depending on the operation type. A Receiver Operating Characteristic (ROC) analysis confirmed this result. Reaction times classified task complexity better when defined by individual ratings. This suggests that participants’ strategy ratings are reliable predictors of arithmetic complexity and should be taken into account in neuroimaging research. PMID:26321997
The correlation between ketamine and posttraumatic stress disorder in burned service members.
McGhee, Laura L; Maani, Christopher V; Garza, Thomas H; Gaylord, Kathryn M; Black, Ian H
2008-02-01
Predisposing factors for posttraumatic stress disorder (PTSD) include experiencing a traumatic event, threat of injury or death, and untreated pain. Ketamine, an anesthetic, is used at low doses as part of a multimodal anesthetic regimen. However, since ketamine is associated with psychosomatic effects, there is a concern that ketamine may increase the risk of developing PTSD. This study investigated the prevalence of PTSD in Operation Iraqi Freedom/Operation Enduring Freedom (OIF/OEF) service members who were treated for burns in a military treatment center. The PTSD Checklist-Military (PCL-M) is a 17-question screening tool for PTSD used by the military. A score of 44 or higher is a positive screen for PTSD. The charts of all OIF/OEF soldiers with burns who completed the PCL-M screening tool (2002-2007) were reviewed to determine the number of surgeries received, the anesthetic regime used, including amounts given, the total body surface area burned, and injury severity score. Morphine equivalent units were calculated using standard dosage conversion factors. The prevalence of PTSD in patients receiving ketamine during their operation(s) was compared with patients not receiving ketamine. Of the 25,000 soldiers injured in OIF/OEF, United States Army Institute of Surgical Research received 603 burned casualties, of which 241 completed the PCL-M. Of those, 147 soldiers underwent at least one operation. Among 119 patients who received ketamine during surgery and 28 who did not; the prevalence of PTSD was 27% (32 of 119) versus 46% (13 of 28), respectively (p = 0.044). Contrary to expectations, patients receiving perioperative ketamine had a lower prevalence of PTSD than soldiers receiving no ketamine during their surgeries despite having larger burns, higher injury severity score, undergoing more operations, and spending more time in the ICU.
A flexible tool for diagnosing water, energy, and entropy budgets in climate models
NASA Astrophysics Data System (ADS)
Lembo, Valerio; Lucarini, Valerio
2017-04-01
We have developed a new flexible software for studying the global energy budget, the hydrological cycle, and the material entropy production of global climate models. The program receives as input radiative, latent and sensible energy fluxes, with the requirement that the variable names are in agreement with the Climate and Forecast (CF) conventions for the production of NetCDF datasets. Annual mean maps, meridional sections and time series are computed by means of Climate Data Operators (CDO) collection of command line operators developed at Max-Planck Institute for Meteorology (MPI-M). If a land-sea mask is provided, the program also computes the required quantities separately on the continents and oceans. Depending on the user's choice, the program also calls the MATLAB software to compute meridional heat transports and location and intensities of the peaks in the two hemispheres. We are currently planning to adapt the program in order to be included in the Earth System Model eValuation Tool (ESMValTool) community diagnostics.
Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung
2015-08-01
Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.
Creating Situational Awareness in Spacecraft Operations with the Machine Learning Approach
NASA Astrophysics Data System (ADS)
Li, Z.
2016-09-01
This paper presents a machine learning approach for the situational awareness capability in spacecraft operations. There are two types of time dependent data patterns for spacecraft datasets: the absolute time pattern (ATP) and the relative time pattern (RTP). The machine learning captures the data patterns of the satellite datasets through the data training during the normal operations, which is represented by its time dependent trend. The data monitoring compares the values of the incoming data with the predictions of machine learning algorithm, which can detect any meaningful changes to a dataset above the noise level. If the difference between the value of incoming telemetry and the machine learning prediction are larger than the threshold defined by the standard deviation of datasets, it could indicate the potential anomaly that may need special attention. The application of the machine-learning approach to the Advanced Himawari Imager (AHI) on Japanese Himawari spacecraft series is presented, which has the same configuration as the Advanced Baseline Imager (ABI) on Geostationary Environment Operational Satellite (GOES) R series. The time dependent trends generated by the data-training algorithm are in excellent agreement with the datasets. The standard deviation in the time dependent trend provides a metric for measuring the data quality, which is particularly useful in evaluating the detector quality for both AHI and ABI with multiple detectors in each channel. The machine-learning approach creates the situational awareness capability, and enables engineers to handle the huge data volume that would have been impossible with the existing approach, and it leads to significant advances to more dynamic, proactive, and autonomous spacecraft operations.
Inside out: meet the operators inside the horizon. On bulk reconstruction behind causal horizons
NASA Astrophysics Data System (ADS)
Almheiri, Ahmed; Anous, Tarek; Lewkowycz, Aitor
2018-01-01
Based on the work of Heemskerk, Marolf, Polchinski and Sully (HMPS), we study the reconstruction of operators behind causal horizons in time dependent geometries obtained by acting with shockwaves on pure states or thermal states. These geometries admit a natural basis of gauge invariant operators, namely those geodesically dressed to the boundary along geodesics which emanate from the bifurcate horizon at constant Rindler time. We outline a procedure for obtaining operators behind the causal horizon but inside the entanglement wedge by exploiting the equality between bulk and boundary time evolution, as well as the freedom to consider the operators evolved by distinct Hamiltonians. This requires we carefully keep track of how the operators are gravitationally dressed and that we address issues regarding background dependence. We compare this procedure to reconstruction using modular flow, and illustrate some formal points in simple cases such as AdS2 and AdS3.
ERIC Educational Resources Information Center
Rantz, William G.; Van Houten, Ron
2011-01-01
This study examined whether pilots operating a flight simulator completed digital or paper flight checklists more accurately after receiving postflight graphic and verbal feedback. The dependent variable was the number of checklist items completed correctly per flight. Following treatment, checklist completion with paper and digital checklists…
NASA Technical Reports Server (NTRS)
Douard, Stephane
1994-01-01
Known as a Graphic Server, the system presented was designed for the control ground segment of the Telecom 2 satellites. It is a tool used to dynamically display telemetry data within graphic pages, also known as views. The views are created off-line through various utilities and then, on the operator's request, displayed and animated in real time as data is received. The system was designed as an independent component, and is installed in different Telecom 2 operational control centers. It enables operators to monitor changes in the platform and satellite payloads in real time. It has been in operation since December 1991.
Miniature Low-Noise G-Band I-Q Receiver
NASA Technical Reports Server (NTRS)
Kangaslahti, Pekka P.; Pukala, David M.; Gaier, Todd C.; Tanner, Alan B.; O'Dwyer, Ian J.; Lambrigtsen, Bjom H.; Soria, Mary M.; Owen, Heather R.; Lai, Richard; Mei, Xiaobing
2010-01-01
Weather forecasting, hurricane tracking, and atmospheric science applications depend on humidity sounding of atmosphere. Current instruments provide these measurements from groundbased, airborne, and low Earth orbit (LEO) satellites by measuring radiometric temperature on the flanks of the 183-GHz water vapor line. Miniature, low-noise receivers have been designed that will enable these measurements from a geostationary, thinned array sounder, which is based on hundreds of low-noise receivers that convert the 180-GHz signal directly to baseband in-phase and in-quadrature signals for digitization and correlation. The developed receivers provide a noise temperature of 450 K from 165 to 183 GHz (NF = 4.1 dB), and have a mass of 3 g while consuming 24 mW of power. These are the most sensitive broadband I-Q receivers at this frequency range that operate at room temperature, and are significantly lower in mass and power consumption than previously reported receivers.
Stability improvement of an operational two-way satellite time and frequency transfer system
NASA Astrophysics Data System (ADS)
Huang, Yi-Jiun; Fujieda, Miho; Takiguchi, Hiroshi; Tseng, Wen-Hung; Tsao, Hen-Wai
2016-04-01
To keep national time accurately coherent with coordinated universal time, many national metrology institutes (NMIs) use two-way satellite time and frequency transfer (TWSTFT) to continuously measure the time difference with other NMIs over an international baseline. Some NMIs have ultra-stable clocks with stability better than 10-16. However, current operational TWSTFT can only provide frequency uncertainty of 10-15 and time uncertainty of 1 ns, which is inadequate. The uncertainty is dominated by the short-term stability and the diurnals, i.e. the measurement variation with a period of one day. The aim of this work is to improve the stability of operational TWSTFT systems without additional transmission, bandwidth or increase in signal power. A software-defined receiver (SDR) comprising a high-resolution correlator and successive interference cancellation associated with open-loop configuration as the TWSTFT receiver reduces the time deviation from 140 ps to 73 ps at averaging time of 1 h, and occasionally suppresses diurnals. To study the source of the diurnals, TWSTFT is performed using a 2 × 2 earth station (ES) array. Consequently, some ESs sensitive to temperature variation are identified, and the diurnals are significantly reduced by employing insensitive ESs. Hence, the operational TWSTFT using the proposed SDR with insensitive ESs achieves time deviation to 41 ps at 1 h, and 80 ps for averaging times from 1 h to 20 h.
Zhang, Xiaoli; Wang, Baojian; Chen, Xuefeng
2015-04-16
With the rapid development of sensor technology, various professional sensors are installed on modern machinery to monitor operational processes and assure operational safety, which play an important role in industry and society. In this work a new operational safety assessment approach with wavelet Rényi entropy utilizing sensor-dependent vibration signals is proposed. On the basis of a professional sensor and the corresponding system, sensor-dependent vibration signals are acquired and analyzed by a second generation wavelet package, which reflects time-varying operational characteristic of individual machinery. Derived from the sensor-dependent signals' wavelet energy distribution over the observed signal frequency range, wavelet Rényi entropy is defined to compute the operational uncertainty of a turbo generator, which is then associated with its operational safety degree. The proposed method is applied in a 50 MW turbo generator, whereupon it is proved to be reasonable and effective for operation and maintenance.
NASA Technical Reports Server (NTRS)
Daly, P.; Koshelyaevsky, N. B.; Lewandowski, Wlodzimierz; Petit, Gerard; Thomas, Claudine
1992-01-01
The University of Leeds built a Global Positioning System/Global Orbiting Navigation Satellite System (GPS/GLONASS) receiver about five years ago and since then has provided continuous information about GLONASS time and its comparison with GPS time. For the last two years, VNIIFTRI (All Union Institute for Physical, Technical and Radiotechnical Measurements) and some other Soviet time laboratories have used Soviet built GLONASS navigation receivers for time comparisons. Since June 1991, VNIIFTIR has been operating a GPS time receiver on loan from the BIPM (Bureau International des Poids et Mesures). This offered, for the first time, an opportunity for direct comparison of time transfers using GPS and GLONASS. This experiment shows that even with relatively imprecise data recording and processing, in terms of time metrology, GLONASS can provide continental time transfer at a level of several tens of nanoseconds.
Safety of remifentanil in transsphenoidal surgery: A single-center analysis of 540 patients.
Cote, David J; Burke, William T; Castlen, Joseph P; King, Chih H; Zaidi, Hasan A; Smith, Timothy R; Laws, Edward R; Aglio, Linda S
2017-04-01
Although some studies have examined the efficacy and safety of remifentanil in patients undergoing neurosurgical procedures, none has examined its safety in transsphenoidal operations specifically. In this study, all transsphenoidal operations performed by a single author from 2008 to 2015 were retrospectively reviewed to evaluate the safety of remifentanil in a consecutive series of patients. During the study period, 540 transsphenoidal operations were identified. Of these, 443 (82.0%) patients received remifentanil intra-operatively; 97 (18.0%) did not. The two groups were well-matched with regard to demographic categories, comorbidities, and pre-operative medications (p>0.05), except pre-operative tobacco use (p=0.021). Patients were also well-matched with regard to radiographic features and surgical techniques. Patients who received remifentanil were more likely to harbor a macroadenoma (78.1% vs. 67.0%, p=0.025), and had slightly longer anesthesia time on average (269.2minvs. 239.4min, p=0.024). All pathologic diagnoses were well-matched between the two groups, except that patients receiving remifentanil were more likely to harbor a non-functioning adenoma (46.5% vs. 26.8%, p<0.001). Analysis of post-operative complications showed no significant difference between patients who received remifentanil and those who did not, and length of stay and prevalence of ICU stay did not differ between the two groups. In a well-matched series of 540 patients undergoing transsphenoidal surgery, remifentanil was found to be a safe anesthetic adjunct. There were no significant differences in post-operative hospital course or complications in patients who did and did not receive intra-operative remifentanil. Copyright © 2016 Elsevier Ltd. All rights reserved.
Demonstration program for Omega receiver prototype microcomputer data processing
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1976-01-01
The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.
Development of wide band digital receiver for atmospheric radars using COTS board based SDR
NASA Astrophysics Data System (ADS)
Yasodha, Polisetti; Jayaraman, Achuthan; Thriveni, A.
2016-07-01
Digital receiver extracts the received echo signal information, and is a potential subsystem for atmospheric radar, also referred to as wind profiling radar (WPR), which provides the vertical profiles of 3-dimensional wind vector in the atmosphere. This paper presents the development of digital receiver using COTS board based Software Defined Radio technique, which can be used for atmospheric radars. The developmental work is being carried out at National Atmospheric Research Laboratory (NARL), Gadanki. The digital receiver consists of a commercially available software defined radio (SDR) board called as universal software radio peripheral B210 (USRP B210) and a personal computer. USRP B210 operates over a wider frequency range from 70 MHz to 6 GHz and hence can be used for variety of radars like Doppler weather radars operating in S/C bands, in addition to wind profiling radars operating in VHF, UHF and L bands. Due to the flexibility and re-configurability of SDR, where the component functionalities are implemented in software, it is easy to modify the software to receive the echoes and process them as per the requirement suitable for the type of the radar intended. Hence, USRP B210 board along with the computer forms a versatile digital receiver from 70 MHz to 6 GHz. It has an inbuilt direct conversion transceiver with two transmit and two receive channels, which can be operated in fully coherent 2x2 MIMO fashion and thus it can be used as a two channel receiver. Multiple USRP B210 boards can be synchronized using the pulse per second (PPS) input provided on the board, to configure multi-channel digital receiver system. RF gain of the transceiver can be varied from 0 to 70 dB. The board can be controlled from the computer via USB 3.0 interface through USRP hardware driver (UHD), which is an open source cross platform driver. The USRP B210 board is connected to the personal computer through USB 3.0. Reference (10 MHz) clock signal from the radar master oscillator is used to lock the board, which is essential for deriving Doppler information. Input from the radar analog receiver is given to one channel of USRP B210, which is down converted to baseband. 12-bit ADC present on the board digitizes the signal and produces I (in-phase) and Q (quadrature-phase) data. The maximum sampling rate possible is about 61 MSPS. The I and Q (time series) data is sent to PC via USB 3.0, where the signal processing is carried out. The online processing steps include decimation, range gating, decoding, coherent integration and FFT computation (optional). The processed data is then stored in the hard disk. C++ programming language is used for developing the real time signal processing. Shared memory along with multi threading is used to collect and process data simultaneously. Before implementing the real time operation, stand alone test of the board was carried out through GNU radio software and the base band output data obtained is found satisfactory. Later the board is integrated with the existing Lower Atmospheric Wind Profiling radar at NARL. The radar receive IF output at 70 MHz is given to the board and the real-time radar data is collected. The data is processed off-line and the range-doppler spectrum is obtained. Online processing software is under progress.
Equatorial late-afternoon periodic TEC fluctuations observed by multiple GPS receivers
NASA Astrophysics Data System (ADS)
Tsugawa, T.; Maruyama, T.; Saito, S.; Ishii, M.
2009-12-01
We report, for the first time, equatorial periodic total electron content (TEC) fluctuations observed in the late afternoon by multiple GPS receivers. As a part of Southeast Asia low-latitude ionospheric network (SEALION), GPS receivers at Chiang Mai and Chumphon, Thailand, have been operated since 2005. We found that periodic TEC fluctuations (PTF) with the periods of 15-30 minutes are often observed at these two sites in the spring (Apr-May) late afternoon. Further investigations using multiple GPS receivers in Southeast Asia revealed that the PTFs propagate at 150-200 m/s away from the equator and their amplitudes depend on the satellite azimuth angle. Statistical study of the PTF activity at different latitudes and longitudes clarified that the PTFs are not observed at mid-latitudes, and their seasonal variations are different at different longitudes and at geomagnetically conjugate regions. These observational results indicate that the PTFs are caused by the atmospheric gravity waves (AGW) which are generated in the equatorial lower atmosphere and propagate away from the equator. Simultaneous GPS-TEC and ionosonde observations at Chumphon revealed that the day-to-day variations of PTF activities are well correlated with those of the rate of TEC change index (ROTI) and the occurrence of equatorial spread F (ESF) after the sunset, indicating the PTFs may be related with the onset of the ESF and plasma bubbles.
NASA Astrophysics Data System (ADS)
Yonezawa, A.; Kuroda, R.; Teramoto, A.; Obara, T.; Sugawa, S.
2014-03-01
We evaluated effective time constants of random telegraph noise (RTN) with various operation timings of in-pixel source follower transistors statistically, and discuss the dependency of RTN time constants on the duty ratio (on/off ratio) of MOSFET which is controlled by the gate to source voltage (VGS). Under a general readout operation of CMOS image sensor (CIS), the row selected pixel-source followers (SFs) turn on and not selected pixel-SFs operate at different bias conditions depending on the select switch position; when select switch locate in between the SF driver and column output line, SF drivers nearly turn off. The duty ratio and cyclic period of selected time of SF driver depends on the operation timing determined by the column read out sequence. By changing the duty ratio from 1 to 7.6 x 10-3, time constant ratio of RTN (time to capture <τc<)/(time to emission <τe<) of a part of MOSFETs increased while RTN amplitudes were almost the same regardless of the duty ratio. In these MOSFETs, <τc< increased and the majority of <τe< decreased and the minority of <τe< increased by decreasing the duty ratio. The same tendencies of behaviors of <τc< and <τe< were obtained when VGS was decreased. This indicates that the effective <τc< and <τe< converge to those under off state as duty ratio decreases. These results are important for the noise reduction, detection and analysis of in pixel-SF with RTN.
The GFZ real-time GNSS precise positioning service system and its adaption for COMPASS
NASA Astrophysics Data System (ADS)
Li, Xingxing; Ge, Maorong; Zhang, Hongping; Nischan, Thomas; Wickert, Jens
2013-03-01
Motivated by the IGS real-time Pilot Project, GFZ has been developing its own real-time precise positioning service for various applications. An operational system at GFZ is now broadcasting real-time orbits, clocks, global ionospheric model, uncalibrated phase delays and regional atmospheric corrections for standard PPP, PPP with ambiguity fixing, single-frequency PPP and regional augmented PPP. To avoid developing various algorithms for different applications, we proposed a uniform algorithm and implemented it into our real-time software. In the new processing scheme, we employed un-differenced raw observations with atmospheric delays as parameters, which are properly constrained by real-time derived global ionospheric model or regional atmospheric corrections and by the empirical characteristics of the atmospheric delay variation in time and space. The positioning performance in terms of convergence time and ambiguity fixing depends mainly on the quality of the received atmospheric information and the spatial and temporal constraints. The un-differenced raw observation model can not only integrate PPP and NRTK into a seamless positioning service, but also syncretize these two techniques into a unique model and algorithm. Furthermore, it is suitable for both dual-frequency and sing-frequency receivers. Based on the real-time data streams from IGS, EUREF and SAPOS reference networks, we can provide services of global precise point positioning (PPP) with 5-10 cm accuracy, PPP with ambiguity-fixing of 2-5 cm accuracy, PPP using single-frequency receiver with accuracy of better than 50 cm and PPP with regional augmentation for instantaneous ambiguity resolution of 1-3 cm accuracy. We adapted the system for current COMPASS to provide PPP service. COMPASS observations from a regional network of nine stations are used for precise orbit determination and clock estimation in simulated real-time mode, the orbit and clock products are applied for real-time precise point positioning. The simulated real-time PPP service confirms that real-time positioning services of accuracy at dm-level and even cm-level is achievable with COMPASS only.
High data rate optical transceiver terminal
NASA Technical Reports Server (NTRS)
Clarke, E. S.
1973-01-01
The objectives of this study were: (1) to design a 400 Mbps optical transceiver terminal to operate from a high-altitude balloon-borne platform in order to permit the quantitative evaluation of a space-qualifiable optical communications system design, (2) to design an atmospheric propagation experiment to operate in conjunction with the terminal to measure the degrading effects of the atmosphere on the links, and (3) to design typical optical communications experiments for space-borne laboratories in the 1980-1990 time frame. As a result of the study, a transceiver package has been configured for demonstration flights during late 1974. The transceiver contains a 400 Mbps transmitter, a 400 Mbps receiver, and acquisition and tracking receivers. The transmitter is a Nd:YAG, 200 Mhz, mode-locked, CW, diode-pumped laser operating at 1.06 um requiring 50 mW for 6 db margin. It will be designed to implement Pulse Quaternary Modulation (PQM). The 400 Mbps receiver utilizes a Dynamic Crossed-Field Photomultiplier (DCFP) detector. The acquisition receiver is a Quadrant Photomultiplier Tube (QPMT) and receives a 400 Mbps signal chopped at 0.1 Mhz.
Wu, Ching-Feng; Gonzalez-Rivas, Diego; Wen, Chih-Tsung; Liu, Yun-Hen; Wu, Yi-Cheng; Chao, Yin-Kai; Hsieh, Ming-Ju; Wu, Ching-Yang; Chen, Wei-Hsun
2015-11-01
Single-port video-assisted thoracoscopic surgery (VATS) has been widely applied recently. However, there are still only few reports describing its use in mediastinum tumor resection. We present the technique of single-port video-assisted thoracoscopic mediastinum tumor resection and compare it with conventional VATS with regard to short-term outcome.We retrospectively enrolled 105 patients who received mediastinum surgery in Chang Gung Memorial Hospital. Sixteen patients received sternotomy or thoracotomy, 29 patients received single-port VATS, and 60 patients received conventional VATS (3 ports). The operative time, blood loss, postoperation day 1 pain score, discharge day pain score, and postoperative hospital stay were compared. In order to establish a well balanced cohort study, we also use propensity scores match (1:1) to compare the short-term clinical outcome in 2 groups.No operative deaths occurred in this study. Single-port VATS was associated with shorter operative time, lower postoperation day 1 pain score, and shorter postoperation hospital stay in our cohort study (P = 0.001, <0.001, and 0.039), and propensity scores matched cohort study (P = 0.003, <0.001, and <0.001).Single-port VATS for mediastinum tumor appears to be a safe and promising technique with short-term outcome not inferior to conventional VATS in our cohort study. The long-term oncology outcome may require time and more enrolled patients to be further evaluated.
Time-dependent phase error correction using digital waveform synthesis
Doerry, Armin W.; Buskirk, Stephen
2017-10-10
The various technologies presented herein relate to correcting a time-dependent phase error generated as part of the formation of a radar waveform. A waveform can be pre-distorted to facilitate correction of an error induced into the waveform by a downstream operation/component in a radar system. For example, amplifier power droop effect can engender a time-dependent phase error in a waveform as part of a radar signal generating operation. The error can be quantified and an according complimentary distortion can be applied to the waveform to facilitate negation of the error during the subsequent processing of the waveform. A time domain correction can be applied by a phase error correction look up table incorporated into a waveform phase generator.
47 CFR 74.1263 - Time of operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FM Broadcast Booster Stations § 74.1263 Time of operation. (a) The licensee of an FM translator or booster station is not required to adhere to any regular schedule of operation. However, the licensee of an FM translator or booster station is expected to provide a dependable service to the extent that...
47 CFR 74.1263 - Time of operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FM Broadcast Booster Stations § 74.1263 Time of operation. (a) The licensee of an FM translator or booster station is not required to adhere to any regular schedule of operation. However, the licensee of an FM translator or booster station is expected to provide a dependable service to the extent that...
47 CFR 74.1263 - Time of operation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FM Broadcast Booster Stations § 74.1263 Time of operation. (a) The licensee of an FM translator or booster station is not required to adhere to any regular schedule of operation. However, the licensee of an FM translator or booster station is expected to provide a dependable service to the extent that...
47 CFR 74.1263 - Time of operation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FM Broadcast Booster Stations § 74.1263 Time of operation. (a) The licensee of an FM translator or booster station is not required to adhere to any regular schedule of operation. However, the licensee of an FM translator or booster station is expected to provide a dependable service to the extent that...
Matching-pursuit/split-operator-Fourier-transform computations of thermal correlation functions.
Chen, Xin; Wu, Yinghua; Batista, Victor S
2005-02-08
A rigorous and practical methodology for evaluating thermal-equilibrium density matrices, finite-temperature time-dependent expectation values, and time-correlation functions is described. The method involves an extension of the matching-pursuit/split-operator-Fourier-transform method to the solution of the Bloch equation via imaginary-time propagation of the density matrix and the evaluation of Heisenberg time-evolution operators through real-time propagation in dynamically adaptive coherent-state representations.
29 CFR 536.3 - “Area of production” as used in section 13(b)(14) of the Fair Labor Standards Act.
Code of Federal Regulations, 2012 CFR
2012-07-01
... calendar month in which operations were carried on for two workweeks or more, except that until such time as an establishment has operated for such a calendar month the period shall be the time during which... and 95 percent of the agricultural commodities received by the establishment for storage or for market...
29 CFR 536.3 - “Area of production” as used in section 13(b)(14) of the Fair Labor Standards Act.
Code of Federal Regulations, 2010 CFR
2010-07-01
... calendar month in which operations were carried on for two workweeks or more, except that until such time as an establishment has operated for such a calendar month the period shall be the time during which... and 95 percent of the agricultural commodities received by the establishment for storage or for market...
29 CFR 536.3 - “Area of production” as used in section 13(b)(14) of the Fair Labor Standards Act.
Code of Federal Regulations, 2011 CFR
2011-07-01
... calendar month in which operations were carried on for two workweeks or more, except that until such time as an establishment has operated for such a calendar month the period shall be the time during which... and 95 percent of the agricultural commodities received by the establishment for storage or for market...
29 CFR 536.3 - “Area of production” as used in section 13(b)(14) of the Fair Labor Standards Act.
Code of Federal Regulations, 2013 CFR
2013-07-01
... calendar month in which operations were carried on for two workweeks or more, except that until such time as an establishment has operated for such a calendar month the period shall be the time during which... and 95 percent of the agricultural commodities received by the establishment for storage or for market...
29 CFR 536.3 - “Area of production” as used in section 13(b)(14) of the Fair Labor Standards Act.
Code of Federal Regulations, 2014 CFR
2014-07-01
... calendar month in which operations were carried on for two workweeks or more, except that until such time as an establishment has operated for such a calendar month the period shall be the time during which... and 95 percent of the agricultural commodities received by the establishment for storage or for market...
Breivik, Cathrine Nansdal; Nilsen, Roy Miodini; Myrseth, Erling; Finnkirk, Monica Katrine; Lund-Johansen, Morten
2013-12-01
We examined whether reduced hearing, tinnitus, dizziness, and unsteadiness affected the patients' ability to maintain work within a time frame of 2-10 years after diagnosis. A total of 434 consecutive patients were followed at regular intervals. Data on symptoms were scored prospectively and dichotomized by visual analog scales for tinnitus and vertigo. Study design is retrospective. Hearing acuity was scored according to the Gardner-Robertson scale, and unsteadiness was measured on a balance platform. Patients were asked about working status, and scored as receiving governmental compensation for disability. Two hundred six patients were eligible for study. Of these, one died and nine were lost to follow-up. Ninety-seven patients received conservative management, 49 patients recieved gamma knife radiosurgery, and 50 patients were treated by microsurgery. Mean follow-up time was 58.7 months (range, 20-132 months). There was a significant increase in the number of individuals receiving compensation during the study period (P < 0.0001). At baseline, the proportion of pension receivers was within same range as that of the age- and sex-matched Norwegian population (5.61% vs. 6.91%; case-control odds ratio, 0.82; 95% confidence interval 0.45-1.49; P = 0.51, not significant). At the final time point, the increase in the number of receivers deviated significantly from the reference population (case-control odds ratio, 3.80; 95% confidence interval 2.71-5.33; P ≤ 0.001). Examining symptoms at first presentation as predictors of future dependence revealed that vertigo and higher mean age were associated with a higher risk (P < 0.001 and P = 0.015, respectively). No other symptoms were predictive of dependence. In a prospectively followed cohort of Norwegian patients with vestibular schwannoma, vestibular complaints were significant predictors for becoming dependant of disability pension. Copyright © 2013 Elsevier Inc. All rights reserved.
Optical-communication systems for deep-space applications
NASA Technical Reports Server (NTRS)
Vilnrotter, V. A.; Gagliardi, R. M.
1980-01-01
The feasibility of using optical communication systems for data telemetry from deep space vehicles to Earth based receivers is evaluated. Performance analysis shows that practical, photon counting optical systems can transmit data reliably at 30 to 40 dB high rates than existing RF systems, or can be used to extend the communication range by 15 to 20 dB. The advantages of pulse-position modulation (PPM) formats are discussed, and photon counting receiver structures designed for PPM decoding are described. The effects of background interference and weather on receiver performance are evaluated. Some consideration is given to tracking and beam pointing operations, since system performance ultimately depends on the accuracy to which these operations can be carried out. An example of a tracking and pointing system utilizing an optical uplink beacon is presented, and it is shown that microradian beam pointing is within the capabilities of state-of-the-art technology. Recommendations for future theoretical studies and component development programs are presented.
49 CFR 37.187 - Interline service.
Code of Federal Regulations, 2011 CFR
2011-10-01
... to Point C. By immediate communication, we mean that the ticket or reservation agent for Operator X, by phone, fax, computer, or other instantaneous means, contacts Operator Y the minute the reservation... service shall ensure that they have the capacity to receive communications at all times concerning...
49 CFR 37.187 - Interline service.
Code of Federal Regulations, 2012 CFR
2012-10-01
... to Point C. By immediate communication, we mean that the ticket or reservation agent for Operator X, by phone, fax, computer, or other instantaneous means, contacts Operator Y the minute the reservation... service shall ensure that they have the capacity to receive communications at all times concerning...
49 CFR 37.187 - Interline service.
Code of Federal Regulations, 2013 CFR
2013-10-01
... to Point C. By immediate communication, we mean that the ticket or reservation agent for Operator X, by phone, fax, computer, or other instantaneous means, contacts Operator Y the minute the reservation... service shall ensure that they have the capacity to receive communications at all times concerning...
Effect of preoperative suggestion on postoperative gastrointestinal motility.
Disbrow, E A; Bennett, H L; Owings, J T
1993-01-01
Autonomic behavior is subject to direct suggestion. We found that patients undergoing major operations benefit more from instruction than from information and reassurance. We compared the return of intestinal function after intra-abdominal operations in 2 groups of patients: the suggestion group received specific instructions for the early return of gastrointestinal motility, and the control group received an equal-length interview offering reassurance and nonspecific instructions. The suggestion group had a significantly shorter average time to the return of intestinal motility, 2.6 versus 4.1 days. Time to discharge was 6.5 versus 8.1 days. Covariates including duration of operation, amount of intraoperative bowel manipulation, and amount of postoperative narcotics were also examined using the statistical model analysis of covariance. An average savings of $1,200 per patient resulted from this simple 5-minute intervention. In summary, the use of specific physiologically active suggestions given preoperatively in a beleivable manner can reduce the morbidity associated with an intra-abdominal operation by reducing the duration of ileus. PMID:8342264
The large discretization step method for time-dependent partial differential equations
NASA Technical Reports Server (NTRS)
Haras, Zigo; Taasan, Shlomo
1995-01-01
A new method for the acceleration of linear and nonlinear time dependent calculations is presented. It is based on the Large Discretization Step (LDS) approximation, defined in this work, which employs an extended system of low accuracy schemes to approximate a high accuracy discrete approximation to a time dependent differential operator. Error bounds on such approximations are derived. These approximations are efficiently implemented in the LDS methods for linear and nonlinear hyperbolic equations, presented here. In these algorithms the high and low accuracy schemes are interpreted as the same discretization of a time dependent operator on fine and coarse grids, respectively. Thus, a system of correction terms and corresponding equations are derived and solved on the coarse grid to yield the fine grid accuracy. These terms are initialized by visiting the fine grid once in many coarse grid time steps. The resulting methods are very general, simple to implement and may be used to accelerate many existing time marching schemes.
Prototype real-time baseband signal combiner. [deep space network
NASA Technical Reports Server (NTRS)
Howard, L. D.
1980-01-01
The design and performance of a prototype real-time baseband signal combiner, used to enhance the received Voyager 2 spacecraft signals during the Jupiter flyby, is described. Hardware delay paths, operating programs, and firmware are discussed.
Limiting the effects of earthquakes on gravitational-wave interferometers
NASA Astrophysics Data System (ADS)
Coughlin, Michael; Earle, Paul; Harms, Jan; Biscans, Sebastien; Buchanan, Christopher; Coughlin, Eric; Donovan, Fred; Fee, Jeremy; Gabbard, Hunter; Guy, Michelle; Mukund, Nikhil; Perry, Matthew
2017-02-01
Ground-based gravitational wave interferometers such as the Laser Interferometer Gravitational-wave Observatory (LIGO) are susceptible to ground shaking from high-magnitude teleseismic events, which can interrupt their operation in science mode and significantly reduce their duty cycle. It can take several hours for a detector to stabilize enough to return to its nominal state for scientific observations. The down time can be reduced if advance warning of impending shaking is received and the impact is suppressed in the isolation system with the goal of maintaining stable operation even at the expense of increased instrumental noise. Here, we describe an early warning system for modern gravitational-wave observatories. The system relies on near real-time earthquake alerts provided by the U.S. Geological Survey (USGS) and the National Oceanic and Atmospheric Administration (NOAA). Preliminary low latency hypocenter and magnitude information is generally available in 5 to 20 min of a significant earthquake depending on its magnitude and location. The alerts are used to estimate arrival times and ground velocities at the gravitational-wave detectors. In general, 90% of the predictions for ground-motion amplitude are within a factor of 5 of measured values. The error in both arrival time and ground-motion prediction introduced by using preliminary, rather than final, hypocenter and magnitude information is minimal. By using a machine learning algorithm, we develop a prediction model that calculates the probability that a given earthquake will prevent a detector from taking data. Our initial results indicate that by using detector control configuration changes, we could prevent interruption of operation from 40 to 100 earthquake events in a 6-month time-period.
Limiting the effects of earthquakes on gravitational-wave interferometers
Coughlin, Michael; Earle, Paul; Harms, Jan; Biscans, Sebastien; Buchanan, Christopher; Coughlin, Eric; Donovan, Fred; Fee, Jeremy; Gabbard, Hunter; Guy, Michelle; Mukund, Nikhil; Perry, Matthew
2017-01-01
Ground-based gravitational wave interferometers such as the Laser Interferometer Gravitational-wave Observatory (LIGO) are susceptible to ground shaking from high-magnitude teleseismic events, which can interrupt their operation in science mode and significantly reduce their duty cycle. It can take several hours for a detector to stabilize enough to return to its nominal state for scientific observations. The down time can be reduced if advance warning of impending shaking is received and the impact is suppressed in the isolation system with the goal of maintaining stable operation even at the expense of increased instrumental noise. Here, we describe an early warning system for modern gravitational-wave observatories. The system relies on near real-time earthquake alerts provided by the U.S. Geological Survey (USGS) and the National Oceanic and Atmospheric Administration (NOAA). Preliminary low latency hypocenter and magnitude information is generally available in 5 to 20 min of a significant earthquake depending on its magnitude and location. The alerts are used to estimate arrival times and ground velocities at the gravitational-wave detectors. In general, 90% of the predictions for ground-motion amplitude are within a factor of 5 of measured values. The error in both arrival time and ground-motion prediction introduced by using preliminary, rather than final, hypocenter and magnitude information is minimal. By using a machine learning algorithm, we develop a prediction model that calculates the probability that a given earthquake will prevent a detector from taking data. Our initial results indicate that by using detector control configuration changes, we could prevent interruption of operation from 40 to 100 earthquake events in a 6-month time-period.
Kuo, Pao-Jen; Wu, Shao-Chun; Chien, Peng-Chen; Chang, Shu-Shya; Rau, Cheng-Shyuan; Tai, Hsueh-Ling; Peng, Shu-Hui; Lin, Yi-Chun; Chen, Yi-Chun; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2018-03-02
The aim of this study was to develop an effective surgical site infection (SSI) prediction model in patients receiving free-flap reconstruction after surgery for head and neck cancer using artificial neural network (ANN), and to compare its predictive power with that of conventional logistic regression (LR). There were 1,836 patients with 1,854 free-flap reconstructions and 438 postoperative SSIs in the dataset for analysis. They were randomly assigned tin ratio of 7:3 into a training set and a test set. Based on comprehensive characteristics of patients and diseases in the absence or presence of operative data, prediction of SSI was performed at two time points (pre-operatively and post-operatively) with a feed-forward ANN and the LR models. In addition to the calculated accuracy, sensitivity, and specificity, the predictive performance of ANN and LR were assessed based on area under the curve (AUC) measures of receiver operator characteristic curves and Brier score. ANN had a significantly higher AUC (0.892) of post-operative prediction and AUC (0.808) of pre-operative prediction than LR (both P <0.0001). In addition, there was significant higher AUC of post-operative prediction than pre-operative prediction by ANN (p<0.0001). With the highest AUC and the lowest Brier score (0.090), the post-operative prediction by ANN had the highest overall predictive performance. The post-operative prediction by ANN had the highest overall performance in predicting SSI after free-flap reconstruction in patients receiving surgery for head and neck cancer.
The University of Colorado OSO-8 spectrometer experiment. IV - Mission operations
NASA Technical Reports Server (NTRS)
Hansen, E. R.; Bruner, E. C., Jr.
1979-01-01
The remote operation of two high-resolution ultraviolet spectrometers on the OSO-8 satellite is discussed. Mission operations enabled scientific observers to plan observations based on current solar data, interact with the observing program using real- or near real-time data and commands, evaluate quick-look instrument data, and analyze the observations for publication. During routine operations, experiments were planned a day prior to their execution, and the data from these experiments received a day later. When a shorter turnaround was required, a real-time mode was available. Here, the real-time data and command links into the remote control center were used to evaluate experiment operation and make satellite pointing or instrument configuration changes with a 1-90 minute turnaround.
Improved Timing Scheme for Spaceborne Precipitation Radar
NASA Technical Reports Server (NTRS)
Berkun, Andrew; Fischman, Mark
2004-01-01
An improved timing scheme has been conceived for operation of a scanning satellite-borne rain-measuring radar system. The scheme allows a real-time-generated solution, which is required for auto targeting. The current timing scheme used in radar satellites involves pre-computing a solution that allows the instrument to catch all transmitted pulses without transmitting and receiving at the same time. Satellite altitude requires many pulses in flight at any time, and the timing solution to prevent transmit and receive operations from colliding is usually found iteratively. The proposed satellite has a large number of scanning beams each with a different range to target and few pulses per beam. Furthermore, the satellite will be self-targeting, so the selection of which beams are used will change from sweep to sweep. The proposed timing solution guarantees no echo collisions, can be generated using simple FPGA-based hardware in real time, and can be mathematically shown to deliver the maximum number of pulses per second, given the timing constraints. The timing solution is computed every sweep, and consists of three phases: (1) a build-up phase, (2) a feedback phase, and (3) a build-down phase. Before the build-up phase can begin, the beams to be transmitted are sorted in numerical order. The numerical order of the beams is also the order from shortest range to longest range. Sorting the list guarantees no pulse collisions. The build-up phase begins by transmitting the first pulse from the first beam on the list. Transmission of this pulse starts a delay counter, which stores the beam number and the time delay to the beginning of the receive window for that beam. The timing generator waits just long enough to complete the transmit pulse plus one receive window, then sends out the second pulse. The second pulse starts a second delay counter, which stores its beam number and time delay. This process continues until an output from the first timer indicates there is less than one transmit pulse width until the start of the next receive event. This blocks future transmit pulses in the build-up phase. The feedback phase begins with the first timer paying off and starting the first receive window. When the first receive window is complete, the timing generator transmits the next beam from the list. When the second timer pays off, the second receive event is started. Following the second receive event, the timing generator will transmit the next beam on the list and start an additional timer. The timers work in a circular buffer fashion so there only need to be enough to cover the maximum number of echoes in flight.
Monolithic optoelectronic integrated broadband optical receiver with graphene photodetectors
NASA Astrophysics Data System (ADS)
Cheng, Chuantong; Huang, Beiju; Mao, Xurui; Zhang, Zanyun; Zhang, Zan; Geng, Zhaoxin; Xue, Ping; Chen, Hongda
2017-07-01
Optical receivers with potentially high operation bandwidth and low cost have received considerable interest due to rapidly growing data traffic and potential Tb/s optical interconnect requirements. Experimental realization of 65 GHz optical signal detection and 262 GHz intrinsic operation speed reveals the significance role of graphene photodetectors (PDs) in optical interconnect domains. In this work, a novel complementary metal oxide semiconductor post-backend process has been developed for integrating graphene PDs onto silicon integrated circuit chips. A prototype monolithic optoelectronic integrated optical receiver has been successfully demonstrated for the first time. Moreover, this is a firstly reported broadband optical receiver benefiting from natural broadband light absorption features of graphene material. This work is a perfect exhibition of the concept of monolithic optoelectronic integration and will pave way to monolithically integrated graphene optoelectronic devices with silicon ICs for three-dimensional optoelectronic integrated circuit chips.
Carrier sense data highway system
Frankel, Robert
1984-02-14
A data transmission system includes a transmission medium which has a certain propagation delay time over its length. A number of data stations are successively coupled to the transmission medium for communicating with one another. Each of the data stations includes a transmitter for originating signals, each signal beginning with a carrier of a duration which is at least the propagation delay time of the transmission medium. Each data station also includes a receiver which receives other signals from other data stations and inhibits operation of the transmitter at the same data station when a carrier of another signal is received.
Comprehensive thermoelectric properties of n- and p-type 78a/o Si - 22a/o Ge alloy
NASA Technical Reports Server (NTRS)
Raag, V.
1978-01-01
The time and temperature dependence of the thermoelectric properties on n- and p-type 78 a/o Si - 22 a/o Ge alloy are presented in detail for the range of temperatures of zero to 1000 C and operating times up to twelve years. The mechanisms responsible for the time dependence of the properties are discussed and mathematical models used in the derivation of the property values from experimental data are presented. The thermoelectric properties for each polarity type of the alloy are presented as a function of temperature for various operating times.
NASA Astrophysics Data System (ADS)
Boenisch, Holger; Froitzheim, Konrad
1999-12-01
The transfer of live media streams such as video and audio over the Internet is subject to several problems, static and dynamic by nature. Important quality of service (QoS) parameters do not only differ between various receivers depending on their network access, service provider, and nationality, the QoS is also variable in time. Moreover the installed receiver base is heterogeneous with respect to operating system, browser or client software, and browser version. We present a new concept for serving live media streams. It is not longer based on the current one-size-fits all paradigm, where the server offers just one stream. Our compresslet system takes the opposite approach: it builds media streams `to order' and `just in time'. Every client subscribing to a media stream uses a servlet loaded into the media server to generate a tailored data stream for his resources and constraints. The server is designed such that commonly used components for media streams are computed once. The compresslets use these prefabricated components, code additional data if necessary, and construct the data stream based on the dynamic available QoS and other client constraints. A client-specific encoding leads to resource- optimal presentation that is especially useful for the presentation of complex multimedia documents on a variety of output devices.
Rodoplu, Ulkümen; Arnold, Jeffrey L; Tokyay, Rifat; Ersoy, Gurkan; Cetiner, Serkan; Yücel, Tayfun
2005-02-01
The authors sought to estimate the impact of the open-air mass-casualty terrorist bombings of the Neve Shalom and Beth Israel Synagogues in Istanbul, Turkey, on November 15, 2003, on the American Hospital (AH) in terms of resource utilization, epidemiologic outcomes, and time course of emergency needs. A retrospective descriptive study using data from hospital records of injured survivors who used the emergency department at AH on November 15, 2003, to determine the number and percentage of injured survivors who were hospitalized, received operative care, had specific injury types, had an Injury Severity Score >/=16, died, and arrived within certain time intervals. AH received 69 (91%) injured survivors from the scene, of which nine (12%) were hospitalized and three (4%) received operative care. Starting four hours after the initial blast, seven (9%) injured survivors were transferred to AH from other hospitals, of which five (7%) were hospitalized and four (5%) received operative care. Of the 49 injured survivors from the scene with documented injuries, 43 (88%) had injuries to the head or face, 42 (86%) had lacerations, five (10%) had fractures, one (2%) had a penetrating eye injury, one (2%) had a serious intracranial injury, and none had primary blast injuries. Four (5%) injured survivors at AH had an Injury Severity Score >/=16, and none died. Seventy-six injured survivors used the emergency department at AH, including a delayed wave of injured survivors transferred from other hospitals. The majority of injured survivors with documented injuries had non-life-threatening lacerations of the head or face, and relatively few injured survivors were hospitalized or received operative care.
Operator assistant to support deep space network link monitor and control
NASA Technical Reports Server (NTRS)
Cooper, Lynne P.; Desai, Rajiv; Martinez, Elmain
1992-01-01
Preparing the Deep Space Network (DSN) stations to support spacecraft missions (referred to as pre-cal, for pre-calibration) is currently an operator and time intensive activity. Operators are responsible for sending and monitoring several hundred operator directivities, messages, and warnings. Operator directives are used to configure and calibrate the various subsystems (antenna, receiver, etc.) necessary to establish a spacecraft link. Messages and warnings are issued by the subsystems upon completion of an operation, changes of status, or an anomalous condition. Some points of pre-cal are logically parallel. Significant time savings could be realized if the existing Link Monitor and Control system (LMC) could support the operator in exploiting the parallelism inherent in pre-cal activities. Currently, operators may work on the individual subsystems in parallel, however, the burden of monitoring these parallel operations resides solely with the operator. Messages, warnings, and directives are all presented as they are received; without being correlated to the event that triggered them. Pre-cal is essentially an overhead activity. During pre-cal, no mission is supported, and no other activity can be performed using the equipment in the link. Therefore, it is highly desirable to reduce pre-cal time as much as possible. One approach to do this, as well as to increase efficiency and reduce errors, is the LMC Operator Assistant (OA). The LMC OA prototype demonstrates an architecture which can be used in concert with the existing LMC to exploit parallelism in pre-cal operations while providing the operators with a true monitoring capability, situational awareness and positive control. This paper presents an overview of the LMC OA architecture and the results from initial prototyping and test activities.
Wang, Xin; Wang, Lei; Zhang, Hao; Li, Ke; Gong, Xiangnan
2016-12-01
The feasibility and clinical application of single-hole video-assisted thoracoscope in pulmonary peripheral tumors was examined. From March, 2011 to March, 2015, we retrospectively analyzed the clinical data obtained from 32 patients with pulmonary peripheral tumor that received single-hole thoracoscopic surgery. We completed the surgery via a 1.5-cm incision on the seventh or eighth rib in midaxillary line as the observation hole, and a 4.0-5.0-cm incision in the lateral margin of pectoralis major in the fourth or fifth rib in midaxillary line as the operation hole. All the patients had completed the tumor-reductive surgery under single-hole thoracoscope successfully. None required second operation hole or needed a transfer to thoracotomy. Operation time was 40-100 min with an average of 65.78±15.87 min. Intraoperative blood loss was 20-100 ml, with an average of 47.19±26.91 ml. Post-operative chest drainage time was 3-6 days, with an average of 4.22±0.87 days. Hospitalization time after operation was 5-7 days, with an average hospitalization time of 5.97±0.82 days. No patient received a second surgery for pulmonary leak or bleeding and no patient had any complication. All the cases recovered without any problem. In conclusion, for patients with pulmonary peripheral tumor, single-hole video-assisted thoracoscope could further reduce their surgical trauma. The operation was safe and feasible and worthy of wide application.
1991-09-30
0196 or 413 545-0720 PI E-mail Address: krithi@nirvan.cs.umass.edu, stankovic(ocs.umass.edu Grant or Contract Title: Dependable Real - Time Systems Grant...Dependable Real - Time Systems " Grant or Contract Number: N00014-85-k-0398 L " Reporting Period: 1 Oct 87 - 30 Sep 91 , 2. Summary of Accomplishments ’ 2.1 Our...in developing a sound approach to scheduling tasks in complex real - time systems , (2) developed a real-time operating system kernel, a preliminary
Drenjanac, Domagoj; Tomic, Slobodanka; Agüera, Juan; Perez-Ruiz, Manuel
2014-10-22
In the new agricultural scenarios, the interaction between autonomous tractors and a human operator is important when they jointly perform a task. Obtaining and exchanging accurate localization information between autonomous tractors and the human operator, working as a team, is a critical to maintaining safety, synchronization, and efficiency during the execution of a mission. An advanced localization system for both entities involved in the joint work, i.e., the autonomous tractors and the human operator, provides a basis for meeting the task requirements. In this paper, different localization techniques for a human operator and an autonomous tractor in a field environment were tested. First, we compared the localization performances of two global navigation satellite systems' (GNSS) receivers carried by the human operator: (1) an internal GNSS receiver built into a handheld device; and (2) an external DGNSS receiver with centimeter-level accuracy. To investigate autonomous tractor localization, a real-time kinematic (RTK)-based localization system installed on autonomous tractor developed for agricultural applications was evaluated. Finally, a hybrid localization approach, which combines distance estimates obtained using a wireless scheme with the position of an autonomous tractor obtained using an RTK-GNSS system, is proposed. The hybrid solution is intended for user localization in unstructured environments in which the GNSS signal is obstructed. The hybrid localization approach has two components: (1) a localization algorithm based on the received signal strength indication (RSSI) from the wireless environment; and (2) the acquisition of the tractor RTK coordinates when the human operator is near the tractor. In five RSSI tests, the best result achieved was an average localization error of 4 m. In tests of real-time position correction between rows, RMS error of 2.4 cm demonstrated that the passes were straight, as was desired for the autonomous tractor. From these preliminary results, future work will address the use of autonomous tractor localization in the hybrid localization approach.
Drenjanac, Domagoj; Tomic, Slobodanka; Agüera, Juan; Perez-Ruiz, Manuel
2014-01-01
In the new agricultural scenarios, the interaction between autonomous tractors and a human operator is important when they jointly perform a task. Obtaining and exchanging accurate localization information between autonomous tractors and the human operator, working as a team, is a critical to maintaining safety, synchronization, and efficiency during the execution of a mission. An advanced localization system for both entities involved in the joint work, i.e., the autonomous tractors and the human operator, provides a basis for meeting the task requirements. In this paper, different localization techniques for a human operator and an autonomous tractor in a field environment were tested. First, we compared the localization performances of two global navigation satellite systems’ (GNSS) receivers carried by the human operator: (1) an internal GNSS receiver built into a handheld device; and (2) an external DGNSS receiver with centimeter-level accuracy. To investigate autonomous tractor localization, a real-time kinematic (RTK)-based localization system installed on autonomous tractor developed for agricultural applications was evaluated. Finally, a hybrid localization approach, which combines distance estimates obtained using a wireless scheme with the position of an autonomous tractor obtained using an RTK-GNSS system, is proposed. The hybrid solution is intended for user localization in unstructured environments in which the GNSS signal is obstructed. The hybrid localization approach has two components: (1) a localization algorithm based on the received signal strength indication (RSSI) from the wireless environment; and (2) the acquisition of the tractor RTK coordinates when the human operator is near the tractor. In five RSSI tests, the best result achieved was an average localization error of 4 m. In tests of real-time position correction between rows, RMS error of 2.4 cm demonstrated that the passes were straight, as was desired for the autonomous tractor. From these preliminary results, future work will address the use of autonomous tractor localization in the hybrid localization approach. PMID:25340450
Dong, L-R; Zhu, Y-M; Xu, Q; Cao, C-X; Zhang, B-Z
2012-01-01
This study investigated whether extraperitoneal colostomy without damaging the muscle layer of the abdominal wall is an improved surgical procedure compared with conventional sigmoid colostomy in patients undergoing abdominoperineal resection. Patients with rectal cancer undergoing abdominoperineal resection were selected and randomly divided into two groups: the study group received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and the control group received conventional colostomy. Clinical data from both groups were analysed. A total of 128 patients were included: 66 received extraperitoneal colostomy without damaging the muscle layer of the abdominal wall and 62 received conventional colostomy. Significant differences between the two groups were found in relation to colostomy operating time, defaecation sensation, bowel control and overall stoma-related complications. Duration of postoperative hospital stay was also significantly different between the study groups. Extraperitoneal colostomy without damaging the muscle layer of the abdominal wall was found to be an improved procedure compared with conventional sigmoid colostomy in abdominoperineal resection, and may reduce colostomy-related complications, shorten operating time and postoperative hospital stay, and potentially improve patients' quality of life.
Delaney, Jesse W; Pinto, Ruxandra; Long, Jennifer; Lamontagne, François; Adhikari, Neill K; Kumar, Anand; Marshall, John C; Cook, Deborah J; Jouvet, Philippe; Ferguson, Niall D; Griesdale, Donald; Burry, Lisa D; Burns, Karen E A; Hutchison, Jamie; Mehta, Sangeeta; Menon, Kusum; Fowler, Robert A
2016-03-30
Patients with 2009 pandemic influenza A(H1N1pdm09)-related critical illness were frequently treated with systemic corticosteroids. While observational studies have reported significant corticosteroid-associated mortality after adjusting for baseline differences in patients treated with corticosteroids or not, corticosteroids have remained a common treatment in subsequent influenza outbreaks, including avian influenza A(H7N9). Our objective was to describe the use of corticosteroids in these patients and investigate predictors of steroid prescription and clinical outcomes, adjusting for both baseline and time-dependent factors. In an observational cohort study of adults with H1N1pdm09-related critical illness from 51 Canadian ICUs, we investigated predictors of steroid administration and outcomes of patients who received and those who did not receive corticosteroids. We adjusted for potential baseline confounding using multivariate logistic regression and propensity score analysis and adjusted for potential time-dependent confounding using marginal structural models. Among 607 patients, corticosteroids were administered to 280 patients (46.1%) at a median daily dose of 227 (interquartile range, 154-443) mg of hydrocortisone equivalents for a median of 7.0 (4.0-13.0) days. Compared with patients who did not receive corticosteroids, patients who received corticosteroids had higher hospital crude mortality (25.5% vs 16.4%, p = 0.007) and fewer ventilator-free days at 28 days (12.5 ± 10.7 vs 15.7 ± 10.1, p < 0.001). The odds ratio association between corticosteroid use and hospital mortality decreased from 1.85 (95% confidence interval 1.12-3.04, p = 0.02) with multivariate logistic regression, to 1.71 (1.05-2.78, p = 0.03) after adjustment for propensity score to receive corticosteroids, to 1.52 (0.90-2.58, p = 0.12) after case-matching on propensity score, and to 0.96 (0.28-3.28, p = 0.95) using marginal structural modeling to adjust for time-dependent between-group differences. Corticosteroids were commonly prescribed for H1N1pdm09-related critical illness. Adjusting for only baseline between-group differences suggested a significant increased risk of death associated with corticosteroids. However, after adjusting for time-dependent differences, we found no significant association between corticosteroids and mortality. These findings highlight the challenges and importance in adjusting for baseline and time-dependent confounders when estimating clinical effects of treatments using observational studies.
Task-dependent signal variations in EEG error-related potentials for brain-computer interfaces.
Iturrate, I; Montesano, L; Minguez, J
2013-04-01
A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user's mental task was independent of the device operation (e.g., the mental task was motor imagery and the operational task was a speller). However, there are some BCIs, such as those based on error-related potentials, where the mental and operational tasks are dependent (e.g., the mental task is to assess the device action and the operational task is the device action itself). The dependence between the mental task and the device operation could introduce a new source of signal variations when the operational task changes, which has not been studied yet. The aim of this study is to analyse task-dependent signal variations and their effect on EEG error-related potentials. The work analyses the EEG variations on the three design steps of BCIs: an electrophysiology study to characterize the existence of these variations, a feature distribution analysis and a single-trial classification analysis to measure the impact on the final BCI performance. The results demonstrate that a change in the operational task produces variations in the potentials, even when EEG activity exclusively originated in brain areas related to error processing is considered. Consequently, the extracted features from the signals vary, and a classifier trained with one operational task presents a significant loss of performance for other tasks, requiring calibration or adaptation for each new task. In addition, a new calibration for each of the studied tasks rapidly outperforms adaptive techniques designed in the literature to mitigate the EEG time-dependent non-stationarities.
Task-dependent signal variations in EEG error-related potentials for brain-computer interfaces
NASA Astrophysics Data System (ADS)
Iturrate, I.; Montesano, L.; Minguez, J.
2013-04-01
Objective. A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user’s mental task was independent of the device operation (e.g., the mental task was motor imagery and the operational task was a speller). However, there are some BCIs, such as those based on error-related potentials, where the mental and operational tasks are dependent (e.g., the mental task is to assess the device action and the operational task is the device action itself). The dependence between the mental task and the device operation could introduce a new source of signal variations when the operational task changes, which has not been studied yet. The aim of this study is to analyse task-dependent signal variations and their effect on EEG error-related potentials.Approach. The work analyses the EEG variations on the three design steps of BCIs: an electrophysiology study to characterize the existence of these variations, a feature distribution analysis and a single-trial classification analysis to measure the impact on the final BCI performance.Results and significance. The results demonstrate that a change in the operational task produces variations in the potentials, even when EEG activity exclusively originated in brain areas related to error processing is considered. Consequently, the extracted features from the signals vary, and a classifier trained with one operational task presents a significant loss of performance for other tasks, requiring calibration or adaptation for each new task. In addition, a new calibration for each of the studied tasks rapidly outperforms adaptive techniques designed in the literature to mitigate the EEG time-dependent non-stationarities.
NASA Technical Reports Server (NTRS)
McLinden, Matthew; Piepmeier, Jeffrey
2013-01-01
The conventional method for integrating a radiometer into radar hardware is to share the RF front end between the instruments, and to have separate IF receivers that take data at separate times. Alternatively, the radar and radiometer could share the antenna through the use of a diplexer, but have completely independent receivers. This novel method shares the radar's RF electronics and digital receiver with the radiometer, while allowing for simultaneous operation of the radar and radiometer. Radars and radiometers, while often having near-identical RF receivers, generally have substantially different IF and baseband receivers. Operation of the two instruments simultaneously is difficult, since airborne radars will pulse at a rate of hundreds of microseconds. Radiometer integration time is typically 10s or 100s of milliseconds. The bandwidth of radar may be 1 to 25 MHz, while a radiometer will have an RF bandwidth of up to a GHz. As such, the conventional method of integrating radar and radiometer hardware is to share the highfrequency RF receiver, but to have separate IF subsystems and digitizers. To avoid corruption of the radiometer data, the radar is turned off during the radiometer dwell time. This method utilizes a modern radar digital receiver to allow simultaneous operation of a radiometer and radar with a shared RF front end and digital receiver. The radiometer signal is coupled out after the first down-conversion stage. From there, the radar transmit frequencies are heavily filtered, and the bands outside the transmit filter are amplified and passed to a detector diode. This diode produces a DC output proportional to the input power. For a conventional radiometer, this level would be digitized. By taking this DC output and mixing it with a system oscillator at 10 MHz, the signal can instead be digitized by a second channel on the radar digital receiver (which typically do not accept DC inputs), and can be down-converted to a DC level again digitally. This unintuitive step allows the digital receiver to sample both the radiometer and radar data at a rapid, synchronized data rate (greater than 1 MHz bandwidth). Once both signals are sampled by the same digital receiver, high-speed quality control can be performed on the radiometer data to allow it to take data simultaneously with the radar. The radiometer data can be blanked during radar transmit, or when the radar return is of a power level high enough to corrupt the radiometer data. Additionally, the receiver protection switches in the RF front end can double as radiometer calibration sources, the short (four-microsecond level) switching periods integrated over many seconds to estimate the radiometer offset. The major benefit of this innovation is that there is minimal impact on the radar performance due to the integration of the radiometer, and the radiometer performance is similarly minimally affected by the radar. As the radar and radiometer are able to operate simultaneously, there is no extended period of integration time loss for the radiometer (maximizing sensitivity), and the radar is able to maintain its full number of pulses (increasing sensitivity and decreasing measurement uncertainty).
NASA Technical Reports Server (NTRS)
Thomas, Claudine
1994-01-01
The Global Positioning System is an outstanding tool for the dissemination of time. Using mono-channel C/A-code GPS time receivers, the restitution of GPS time through the satellite constellation presents a peak-to-peak discrepancy of several tens of nanoseconds without SA but may be as high as several hundreds of nanoseconds with SA. As a consequence, civil users are more and more interested in implementing hardware and software methods for efficient restitution of GPS time, especially in the framework of the project of a real-time prediction of UTC (UTCp) which could be available in the form of time differences (UTCp - GPS time). Previous work, for improving the real-time restitution of GPS time with SA, to the level obtained without SA, focused on the implementation of a Kalman filter based on past data and updated at each new observation. An alternative solution relies upon the statistical features of the noise brought about by SA; it has already been shown that the SA noise is efficiently reduced by averaging data from numerous satellites observed simultaneously over a sufficiently long time. This method was successfully applied to data from a GPS time receiver, model AOA TTR-4P, connected to the cesium clock kept at the BIPM. This device, a multi-channel, dual frequency, P-code GPS time receiver, is one of the first TTR-4P units in operation in a civil laboratory. Preliminary comparative studies of this new equipment with conventional GPS time receivers are described in this paper. The results of an experimental restitution of GPS time, obtained in June 1993, are also detailed: 3 to 6 satellites were observed simultaneously with a sample interval of 15 s, an efficient smoothing of SA noise was realized by averaging data on all observed satellites over more than 1 hour. When the GPS system is complete in 1994, 8 satellites will be observable continuously from anywhere in the world and the same level of uncertainty will be obtained using a shorter averaging time.
User's manual for the time-dependent INERTIA code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bailey, A.W.; Bennett, R.B.
1985-01-01
The time-dependent INERTIA code is described. This code models the effects of neutral beam momentum input in tokamaks as predicted by the time-dependent formulation of the Stacey-Sigmar formalism. The operation and architecture of the code are described, as are the supplementary plotting and impurity line radiation routines. A short description of the steady-state version of the INERTIA code is also provided.
Tokamak power reactor ignition and time dependent fractional power operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vold, E.L.; Mau, T.K.; Conn, R.W.
1986-06-01
A flexible time-dependent and zero-dimensional plasma burn code with radial profiles was developed and employed to study the fractional power operation and the thermal burn control options for an INTOR-sized tokamak reactor. The code includes alpha thermalization and a time-dependent transport loss which can be represented by any one of several currently popular scaling laws for energy confinement time. Ignition parameters were found to vary widely in density-temperature (n-T) space for the range of scaling laws examined. Critical ignition issues were found to include the extent of confinement time degradation by alpha heating, the ratio of ion to electron transportmore » power loss, and effect of auxiliary heating on confinement. Feedback control of the auxiliary power and ion fuel sources are shown to provide thermal stability near the ignition curve.« less
A brief measure of high nicotine dependence for busy clinicians and large epidemiological surveys.
Diaz, Francisco J; Jané, Mireia; Saltó, Esteve; Pardell, Hélios; Salleras, Lluís; Pinet, Cristina; de Leon, Jose
2005-03-01
It is important to perform a routine screening of nicotine dependence in psychiatric patients. The Fagerstrom Test for Nicotine Dependence (FTND) is a widely used six-item questionnaire. The Heavy Smoking Index (HSI) is a briefer measure including only two FTND items (time to first cigarette of day and number of daily cigarettes). In a prior study comparing HSI with FTND, a high HSI (score > or = 4) was a good and briefer alternative for detecting high nicotine dependence. The goals of this study were: (i) to compare the effectiveness of the HSI with the effectiveness of Items 1 and 4 alone for the screening of high nicotine dependence; (ii) to investigate the optimality of 4 as a cut-off score for the HSI so that the HSI can be used as a binary indicator of high nicotine dependence; and (iii) to compare the sensitivity and specificity of four indexes of high nicotine dependence, namely 'High HSI', 'Very Early Smoking', 'Heavy Smoking' and 'High in Either Item'. The FTND was administered to 819 current daily smokers from a general population survey. As in a prior study, an FTND score > or = 6 was considered the reference or 'gold standard' test for detecting high nicotine dependence. Receiver-operating characteristic analyses were performed. This new study using more sophisticated statistical methodology verified that a cut-off of 4 for the HSI is appropriate and that the 'high' HSI has good sensitivity and specificity even across different population subclassifications. With four questions (smoking, daily smoking, time to first cigarette of day and number of daily cigarettes) and minimal calculations, it may be possible to screen whether a smoker has high nicotine dependence. If other studies in other populations and settings verify this finding, this brief measure might be an ideal screening instrument for busy clinicians, epidemiologists developing questionnaires for health surveys and psychiatric researchers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, Lorraine; Cox, Jennifer; Faculty of Health Sciences, University of Sydney, Sydney, New South Wales
2015-09-15
The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 daysmore » post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.« less
Sear, Rose; Rees, Jeremy; Buller, Zairah; Moore, Simon C
2018-05-01
To assess the feasibility of using short message service text messages to solicit dental patients' experiences of post-operative dental discomfort and sensitivity (PODDS) and whether responses characterise change in PODDS over time. Patients were recruited from clinics following routine dental procedures, such as simple restorations or root surface debridement. They completed a short questionnaire collecting information on socio-economic circumstances, their recent experience of PODDS, the acceptability of receiving text message questions and their telephone number. Participants received a short question by text to their telephone for five consecutive days that asked them to respond with an indication (on a 1 to 10 scale) of their experience of PODDS at that time. Questionnaires were completed by 34 participants, of whom text message responses were received from an average of 23.4 participants (min 20, max 26) across the five follow-up days. Regression analyses indicated that PODDS decreased over time (β = -0.24, 95% CI -0.36 to -0.12). Text messaging to solicit PODDS is feasible and can potentially be used to assess the efficacy of treatments designed to minimise or reduce PODDS. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhang, Xiaoli; Wang, Baojian; Chen, Xuefeng
2015-01-01
With the rapid development of sensor technology, various professional sensors are installed on modern machinery to monitor operational processes and assure operational safety, which play an important role in industry and society. In this work a new operational safety assessment approach with wavelet Rényi entropy utilizing sensor-dependent vibration signals is proposed. On the basis of a professional sensor and the corresponding system, sensor-dependent vibration signals are acquired and analyzed by a second generation wavelet package, which reflects time-varying operational characteristic of individual machinery. Derived from the sensor-dependent signals’ wavelet energy distribution over the observed signal frequency range, wavelet Rényi entropy is defined to compute the operational uncertainty of a turbo generator, which is then associated with its operational safety degree. The proposed method is applied in a 50 MW turbo generator, whereupon it is proved to be reasonable and effective for operation and maintenance. PMID:25894934
Method for Real-Time Model Based Structural Anomaly Detection
NASA Technical Reports Server (NTRS)
Urnes, James M., Sr. (Inventor); Smith, Timothy A. (Inventor); Reichenbach, Eric Y. (Inventor)
2015-01-01
A system and methods for real-time model based vehicle structural anomaly detection are disclosed. A real-time measurement corresponding to a location on a vehicle structure during an operation of the vehicle is received, and the real-time measurement is compared to expected operation data for the location to provide a modeling error signal. A statistical significance of the modeling error signal to provide an error significance is calculated, and a persistence of the error significance is determined. A structural anomaly is indicated, if the persistence exceeds a persistence threshold value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Volker, Arno; Hunter, Alan
Anisotropic materials are being used increasingly in high performance industrial applications, particularly in the aeronautical and nuclear industries. Some important examples of these materials are composites, single-crystal and heavy-grained metals. Ultrasonic array imaging in these materials requires exact knowledge of the anisotropic material properties. Without this information, the images can be adversely affected, causing a reduction in defect detection and characterization performance. The imaging operation can be formulated in two consecutive and reciprocal focusing steps, i.e., focusing the sources and then focusing the receivers. Applying just one of these focusing steps yields an interesting intermediate domain. The resulting common focusmore » point gather (CFP-gather) can be interpreted to determine the propagation operator. After focusing the sources, the observed travel-time in the CFP-gather describes the propagation from the focus point to the receivers. If the correct propagation operator is used, the measured travel-times should be the same as the time-reversed focusing operator due to reciprocity. This makes it possible to iteratively update the focusing operator using the data only and allows the material to be imaged without explicit knowledge of the anisotropic material parameters. Furthermore, the determined propagation operator can also be used to invert for the anisotropic medium parameters. This paper details the proposed technique and demonstrates its use on simulated array data from a specimen of Inconel single-crystal alloy commonly used in the aeronautical and nuclear industries.« less
46 CFR 10.107 - Definitions in subchapter B.
Code of Federal Regulations, 2012 CFR
2012-10-01
... officer. Ballast control operator or BCO means an officer restricted to service on mobile offshore... attend classes, make contributions of time or money, receive treatment, submit to any manner of probation.... Mobile offshore drilling unit or MODU means a vessel capable of engaging in drilling operations for the...
46 CFR 10.107 - Definitions in subchapter B.
Code of Federal Regulations, 2013 CFR
2013-10-01
... officer. Ballast control operator or BCO means an officer restricted to service on mobile offshore... attend classes, make contributions of time or money, receive treatment, submit to any manner of probation.... Mobile offshore drilling unit or MODU means a vessel capable of engaging in drilling operations for the...
Evaluation of GPS Coverage for the X-33 Michael-6 Trajectory
NASA Technical Reports Server (NTRS)
Lundberg, John B.
1998-01-01
The onboard navigational system for the X-33 test flights will be based on the use of measurements collected from the Embedded Global Positioning System (GPS)/INS system. Some of the factors which will affect the quality of the GPS contribution to the navigational solution will be the number of pseudorange measurements collected at any instant in time, the distribution of the GPS satellites within the field of view, and the inherent noise level of the GPS receiver. The distribution of GPS satellites within the field of view of the receiver's antenna will depend on the receiver's position, the time of day, pointing direction of the antenna, and the effective cone angle of the antenna. The number of pseudorange measurements collected will depend upon these factors as well as the time required to lock onto a GPS satellite signal once the GPS satellite comes into the field of view of the antenna and the number of available receiver channels. The objective of this study is to evaluate the GPS coverage resulting from the proposed antenna pointing directions, the proposed antenna cone angles, and the effects due to the time of day for the X-33 Michael-6 trajectory from launch at Edwards AFB, California, to the start of the Terminal Area Energy Management (TAEM) phase on approach to Michael AAF, Utah.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Kristan D.; Faraj, Daniel A.
In a parallel computer, a largest logical plane from a plurality of logical planes formed of compute nodes of a subcommunicator may be identified by: identifying, by each compute node of the subcommunicator, all logical planes that include the compute node; calculating, by each compute node for each identified logical plane that includes the compute node, an area of the identified logical plane; initiating, by a root node of the subcommunicator, a gather operation; receiving, by the root node from each compute node of the subcommunicator, each node's calculated areas as contribution data to the gather operation; and identifying, bymore » the root node in dependence upon the received calculated areas, a logical plane of the subcommunicator having the greatest area.« less
Yang, Xinsong; Feng, Zhiguo; Feng, Jianwen; Cao, Jinde
2017-01-01
In this paper, synchronization in an array of discrete-time neural networks (DTNNs) with time-varying delays coupled by Markov jump topologies is considered. It is assumed that the switching information can be collected by a tracker with a certain probability and transmitted from the tracker to controller precisely. Then the controller selects suitable control gains based on the received switching information to synchronize the network. This new control scheme makes full use of received information and overcomes the shortcomings of mode-dependent and mode-independent control schemes. Moreover, the proposed control method includes both the mode-dependent and mode-independent control techniques as special cases. By using linear matrix inequality (LMI) method and designing new Lyapunov functionals, delay-dependent conditions are derived to guarantee that the DTNNs with Markov jump topologies to be asymptotically synchronized. Compared with existing results on Markov systems which are obtained by separately using mode-dependent and mode-independent methods, our result has great flexibility in practical applications. Numerical simulations are finally given to demonstrate the effectiveness of the theoretical results. Copyright © 2016 Elsevier Ltd. All rights reserved.
Structural analysis of a reflux pool-boiler solar receiver
NASA Astrophysics Data System (ADS)
Hoffman, E. L.; Stone, C. M.
1991-06-01
Coupled thermal-structural finite element calculations of a reflux pool-boiler solar receiver were performed to characterize the operating stresses and to address issues affecting the service life of the receiver. Analyses performed using shell elements provided information for receiver material selection and design optimization. Calculations based on linear elastic fracture mechanics principles were performed using continuum elements to assess the vulnerability of a seam-weld to fatigue crack growth. All calculations were performed using ABAQUS, a general purpose finite element code, and elements specifically formulated for coupled thermal-structural analysis. Two materials were evaluated: 316L SS and Haynes 230 alloys. The receiver response was simulated for a combination of structural and thermal loads that represent the startup and operating conditions of the receiver. For both materials, maximum stresses in the receiver developed shortly after startup due to uneven temperature distribution across the receiver surface. The largest effective stress was near yield in the 316L SS receiver and below 39 percent of yield in the Haynes 230 receiver. The calculations demonstrated that stress reductions of over 25 percent could be obtained by reducing the aft dome thickness to one closer to the absorber. The fatigue calculations demonstrated that the stress distribution near the seam-weld notch depends primarily on the structural load created by internal pressurization of the receiver rather than the thermal, indicating that the thermal loads can be neglected when assessing the stress intensity near the seam-weld notch. The stress intensity factor, computed using the J-integral method and crack opening-displacement field equations, was significantly below the fatigue threshold for most steels. The calculations indicated that the weld notch was always loaded in compression, a condition which is not conducive to fatigue crack growth.
Predictors of shoulder dystocia at the time of operative vaginal delivery.
Palatnik, Anna; Grobman, William A; Hellendag, Madeline G; Janetos, Timothy M; Gossett, Dana R; Miller, Emily S
2016-11-01
It remains uncertain whether clinical factors known prior to delivery can predict which women are more likely to experience shoulder dystocia in the setting of operative vaginal delivery. We sought to identify whether shoulder dystocia can be accurately predicted among women undergoing an operative vaginal delivery. This was a case-control study of women undergoing a low or outlet operative vaginal delivery from 2005 through 2014 in a single tertiary care center. Cases were defined as women who experienced a shoulder dystocia at the time of operative vaginal delivery. Controls consisted of women without a shoulder dystocia at the time of operative vaginal delivery. Variables previously identified to be associated with shoulder dystocia that could be known prior to delivery were abstracted from the medical records. Bivariable analyses and multivariable logistic regression were used to identify factors independently associated with shoulder dystocia. A receiver operating characteristic curve was created to evaluate the predictive value of the model for shoulder dystocia. Of the 4080 women who met inclusion criteria, shoulder dystocia occurred in 162 (4.0%) women. In bivariable analysis, maternal age, parity, body mass index, diabetes, chorioamnionitis, arrest disorder as an indication for an operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg were significantly associated with shoulder dystocia. In multivariable analysis, parity, diabetes, chorioamnionitis, arrest disorder as an indication for operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg remained independently associated with shoulder dystocia. The area under the curve for the generated receiver operating characteristic curve was 0.73 (95% confidence interval, 0.69-0.77), demonstrating only a modest ability to predict shoulder dystocia before performing an operative vaginal delivery. While risk factors for shoulder dystocia at the time of operative vaginal delivery can be identified, reliable prediction of shoulder dystocia in this setting cannot be attained. Copyright © 2016 Elsevier Inc. All rights reserved.
The Variance Reaction Time Model
ERIC Educational Resources Information Center
Sikstrom, Sverker
2004-01-01
The variance reaction time model (VRTM) is proposed to account for various recognition data on reaction time, the mirror effect, receiver-operating-characteristic (ROC) curves, etc. The model is based on simple and plausible assumptions within a neural network: VRTM is a two layer neural network where one layer represents items and one layer…
Analysis of cache for streaming tape drive
NASA Technical Reports Server (NTRS)
Chinnaswamy, V.
1993-01-01
A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape drive. Some examples are given illustrating the usefulness of these formulas. Finally, a summary and some conclusions are provided.
DeFulio, Anthony; Donlin, Wendy D; Wong, Conrad J; Silverman, Kenneth
2009-09-01
Due to the chronic nature of cocaine dependence, long-term maintenance treatments may be required to sustain abstinence. Abstinence reinforcement is among the most effective means of initiating cocaine abstinence. Practical and effective means of maintaining abstinence reinforcement programs over time are needed. To determine whether employment-based abstinence reinforcement can be an effective long-term maintenance intervention for cocaine dependence. Participants (n = 128) were enrolled in a 6-month job skills training and abstinence initiation program. Participants who initiated abstinence, attended regularly and developed needed job skills during the first 6 months were hired as operators in a data entry business and assigned randomly to an employment-only (control, n = 24) or abstinence-contingent employment (n = 27) group. A non-profit data entry business. Participants Unemployed welfare recipients who used cocaine persistently while enrolled in methadone treatment in Baltimore. Abstinence-contingent employment participants received 1 year of employment-based contingency management, in which access to employment was contingent upon provision of drug-free urine samples under routine and then random drug testing. If a participant provided drug-positive urine or failed to provide a mandatory sample, then that participant received a temporary reduction in pay and could not work until urinalysis confirmed recent abstinence. Cocaine-negative urine samples at monthly assessments across 1 year of employment. During the 1 year of employment, abstinence-contingent employment participants provided significantly more cocaine-negative urine samples than employment-only participants [79.3% and 50.7%, respectively; P = 0.004, odds ratio (OR) = 3.73, 95% confidence interval (CI) = 1.60-8.69]. Conclusions Employment-based abstinence reinforcement that includes random drug testing is effective as a long-term maintenance intervention, and is among the most promising treatments for drug dependence. Work-places could serve as therapeutic agents in the treatment of drug dependence by arranging long-term employment-based contingency management programs.
Age, Dose, and Time-Dependency of Plasma and Tissue Distribution of Deltamethrine in Immature Rats
The major objective of this project was to characterize the systemic disposition of the pyrethroid, deltamethrin (DLT), in immature rats, with emphasis on the age-dependence of target organ (brain) dosimetry. Postnatal day (PND) 10, 21, and 40 male Sprague-Dawley rats received 0...
Bajaj, Jasmohan S; Heuman, Douglas M; Sterling, Richard K; Sanyal, Arun J; Siddiqui, Muhammad; Matherly, Scott; Luketic, Velimir; Stravitz, R Todd; Fuchs, Michael; Thacker, Leroy R; Gilles, HoChong; White, Melanie B; Unser, Ariel; Hovermale, James; Gavis, Edith; Noble, Nicole A; Wade, James B
2015-10-01
Detection of covert hepatic encephalopathy (CHE) is difficult, but point-of-care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test-retest reliability, and external validity. Patients with cirrhosis (n = 167; 38% with overt HE [OHE]; mean age, 55 years; mean Model for End-Stage Liver Disease score, 12) and controls (n = 114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test-retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intrahepatic portosystemic shunt placement, and before and after correction for hyponatremia, to determine external validity. All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cutoffs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic value of 0.91; the area under the receiver operator characteristic value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test-retest reliability was high (intraclass coefficient, 0.83) among 30 patients retested 1-3 months apart. OffTime+OnTime increased significantly (206 vs 255 seconds, P = .007) among 10 patients retested 33 ± 7 days after transjugular intrahepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225 seconds, P = .03) in 7 patients tested before and after correction for hyponatremia (126 ± 3 to 132 ± 4 meq/L, P = .01) 10 ± 5 days apart. A smartphone app called EncephalApp has good face validity, test-retest reliability, and external validity for the diagnosis of CHE. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Sato, Atsushi; Okuda, Yutaka; Fujita, Takaaki; Kimura, Norihiko; Hoshina, Noriyuki; Kato, Sayaka; Tanaka, Shigenari
2016-01-01
This study aimed to clarify which cognitive and physical factors are associated with the need for toileting assistance in stroke patients and to calculate cut-off values for discriminating between independent supervision and dependent toileting ability. This cross-sectional study included 163 first-stroke patients in nine convalescent rehabilitation wards. Based on their FIM Ⓡ instrument score for toileting, the patients were divided into an independent-supervision group and a dependent group. Multiple logistic regression analysis and receiver operating characteristic analysis were performed to identify factors related to toileting performance. The Minimental State Examination (MMSE); the Stroke Impairment Assessment Set (SIAS) score for the affected lower limb, speech, and visuospatial functions; and the Functional Assessment for Control of Trunk (FACT) were analyzed as independent variables. The multiple logistic regression analysis showed that the FIM Ⓡ instrument score for toileting was associated with the SIAS score for the affected lower limb function, MMSE, and FACT. On receiver operating characteristic analysis, the SIAS score for the affected lower limb function cut-off value was 8/7 points, the MMSE cut-off value was 25/24 points, and the FACT cut-off value was 14/13 points. Affected lower limb function, cognitive function, and trunk function were related with the need for toileting assistance. These cut-off values may be useful for judging whether toileting assistance is needed in stroke patients.
Shuttle remote manipulator system mission preparation and operations
NASA Technical Reports Server (NTRS)
Smith, Ernest E., Jr.
1989-01-01
The preflight planning, analysis, procedures development, and operations support for the Space Transportation System payload deployment and retrieval missions utilizing the Shuttle Remote Manipulator System are summarized. Analysis of the normal operational loads and failure induced loads and motion are factored into all procedures. Both the astronaut flight crews and the Mission Control Center flight control teams receive considerable training for standard and mission specific operations. The real time flight control team activities are described.
System and method for motor fault detection using stator current noise cancellation
Zhou, Wei; Lu, Bin; Nowak, Michael P.; Dimino, Steven A.
2010-12-07
A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to acquire at least on additional set of real-time operating current data from the motor during operation, redefine the noise component present in each additional set of real-time operating current data, and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.
Fiber optic spectroscopic digital imaging sensor and method for flame properties monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelepouga, Serguei A; Rue, David M; Saveliev, Alexei V
2011-03-15
A system for real-time monitoring of flame properties in combustors and gasifiers which includes an imaging fiber optic bundle having a light receiving end and a light output end and a spectroscopic imaging system operably connected with the light output end of the imaging fiber optic bundle. Focusing of the light received by the light receiving end of the imaging fiber optic bundle by a wall disposed between the light receiving end of the fiber optic bundle and a light source, which wall forms a pinhole opening aligned with the light receiving end.
Kuo, Pao-Jen; Wu, Shao-Chun; Chien, Peng-Chen; Chang, Shu-Shya; Rau, Cheng-Shyuan; Tai, Hsueh-Ling; Peng, Shu-Hui; Lin, Yi-Chun; Chen, Yi-Chun; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2018-01-01
Background The aim of this study was to develop an effective surgical site infection (SSI) prediction model in patients receiving free-flap reconstruction after surgery for head and neck cancer using artificial neural network (ANN), and to compare its predictive power with that of conventional logistic regression (LR). Materials and methods There were 1,836 patients with 1,854 free-flap reconstructions and 438 postoperative SSIs in the dataset for analysis. They were randomly assigned tin ratio of 7:3 into a training set and a test set. Based on comprehensive characteristics of patients and diseases in the absence or presence of operative data, prediction of SSI was performed at two time points (pre-operatively and post-operatively) with a feed-forward ANN and the LR models. In addition to the calculated accuracy, sensitivity, and specificity, the predictive performance of ANN and LR were assessed based on area under the curve (AUC) measures of receiver operator characteristic curves and Brier score. Results ANN had a significantly higher AUC (0.892) of post-operative prediction and AUC (0.808) of pre-operative prediction than LR (both P<0.0001). In addition, there was significant higher AUC of post-operative prediction than pre-operative prediction by ANN (p<0.0001). With the highest AUC and the lowest Brier score (0.090), the post-operative prediction by ANN had the highest overall predictive performance. Conclusion The post-operative prediction by ANN had the highest overall performance in predicting SSI after free-flap reconstruction in patients receiving surgery for head and neck cancer. PMID:29568393
Timing Recovery Strategies in Magnetic Recording Systems
NASA Astrophysics Data System (ADS)
Kovintavewat, Piya
At some point in a digital communications receiver, the received analog signal must be sampled. Good performance requires that these samples be taken at the right times. The process of synchronizing the sampler with the received analog waveform is known as timing recovery. Conventional timing recovery techniques perform well only when operating at high signal-to-noise ratio (SNR). Nonetheless, iterative error-control codes allow reliable communication at very low SNR, where conventional techniques fail. This paper provides a detailed review on the timing recovery strategies based on per-survivor processing (PSP) that are capable of working at low SNR. We also investigate their performance in magnetic recording systems because magnetic recording is a primary method of storage for a variety of applications, including desktop, mobile, and server systems. Results indicate that the timing recovery strategies based on PSP perform better than the conventional ones and are thus worth being employed in magnetic recording systems.
Advanced ground station architecture
NASA Technical Reports Server (NTRS)
Zillig, David; Benjamin, Ted
1994-01-01
This paper describes a new station architecture for NASA's Ground Network (GN). The architecture makes efficient use of emerging technologies to provide dramatic reductions in size, operational complexity, and operational and maintenance costs. The architecture, which is based on recent receiver work sponsored by the Office of Space Communications Advanced Systems Program, allows integration of both GN and Space Network (SN) modes of operation in the same electronics system. It is highly configurable through software and the use of charged coupled device (CCD) technology to provide a wide range of operating modes. Moreover, it affords modularity of features which are optional depending on the application. The resulting system incorporates advanced RF, digital, and remote control technology capable of introducing significant operational, performance, and cost benefits to a variety of NASA communications and tracking applications.
Characteristics of High Latitude Ionosphere Scintillations
NASA Astrophysics Data System (ADS)
Morton, Y.
2012-12-01
As we enter a new solar maximum period, global navigation satellite systems (GNSS) receivers, especially the ones operating in high latitude and equatorial regions, are facing an increasing threat from ionosphere scintillations. The increased solar activities, however, also offer a great opportunity to collect scintillation data to characterize scintillation signal parameters and ionosphere irregularities. While there are numerous GPS receivers deployed around the globe to monitor ionosphere scintillations, most of them are commercial receivers whose signal processing mechanisms are not designed to operate under ionosphere scintillation. As a result, they may distort scintillation signal parameters or lose lock of satellite signals under strong scintillations. Since 2008, we have established and continuously improved a unique GNSS receiver array at HAARP, Alaska. The array contains high ends commercial receivers and custom RF front ends which can be automatically triggered to collect high quality GPS and GLONASS satellite signals during controlled heating experiments and natural scintillation events. Custom designed receiver signal tracking algorithms aim to preserve true scintillation signatures are used to process the raw RF samples. Signal strength, carrier phase, and relative TEC measurements generated by the receiver array since its inception have been analyzed to characterize high latitude scintillation phenomena. Daily, seasonal, and solar events dependency of scintillation occurrence, spectral contents of scintillation activities, and plasma drifts derived from these measurements will be presented. These interesting results demonstrate the feasibility and effectiveness of our experimental data collection system in providing insightful details of ionosphere responses to active perturbations and natural disturbances.
Novel low-cost millimeter-wave system for road surface characterization
NASA Astrophysics Data System (ADS)
Busuioc, Dan; Anstey, Kyle; Rappaport, Carey; Birken, Ralf; Doughty, Jeffrey; Wang, Ming
2011-04-01
A novel low-cost low-complexity design based on Radar technology operating at millimeter wave is presented for the characterization of road surface conditions in real-time. At frequencies of 24-77 GHz the wavelength is long enough to obtain slight penetration in the top 1-2" of asphalt or concrete surface, but is also short enough to resolve details such as crack or pothole depth/etc. The Radar system operates by continuously outputting radiation and sampling the roadway-reflected radiation through a receiver-downconverter-sampler system. In initial laboratory testing, the received signal strength was observed to obey the inverse distance 1/R2 relationship. The received signal is further dependent on the incidence angle between the plane of the sensor and the plane of the roadway. One observation from this is the need of auxiliary sensors for determining the distance above the road surface as well as providing incident angle data. The sensor was further mounted on a movable cart used to measure the reflected signal on a variety of road surfaces (smooth, rough, surface defects, and environment factors such as various levels of moisture). By comparing measurements of the material after soaking to measurements in the dry state, there is substantial differentiation in measurements, which indicates the ability to measure the porosity of various materials. Lastly the sensor bandwidth provides the capability to measure surface roughness illustrated in the standard deviation of measurement data. On a macroscopic level, the aggregate in a roadway acts as a series of random scatterers and rough roadways or roadways with surface voids show a large variance between measurements of nearby points.
Strandbygaard, Jeanett; Bjerrum, Flemming; Maagaard, Mathilde; Winkel, Per; Larsen, Christian Rifbjerg; Ringsted, Charlotte; Gluud, Christian; Grantcharov, Teodor; Ottesen, Bent; Sorensen, Jette Led
2013-05-01
To investigate the impact of instructor feedback versus no instructor feedback when training a complex operational task on a laparoscopic virtual reality simulator. : Simulators are now widely accepted as a training tool, but there is insufficient knowledge about how much feedback is necessary, which is useful for sustainable implementation. A randomized trial complying with CONSORT Statement. All participants had to reach a predefined proficiency level for a complex operational task on a virtual reality simulator. The intervention group received standardized instructor feedback a maximum of 3 times. The control group did not receive instructor feedback. Participants were senior medical students without prior laparoscopic experience (n = 99). Outcome measures were time, repetitions, and performance score to reach a predefined proficiency level. Furthermore, influence of sex and perception of own surgical skills were examined. Time (in minutes) and repetitions were reduced in the intervention group (162 vs 342 minutes; P < 0.005) and (29 vs 65 repetitions; P < 0.005). The control group achieved a higher performance score than the intervention group (57% vs 49%; P = 0.004). Men used less time (in minutes) than women (P = 0.037), but no sex difference was observed for repetitions (P = 0.20). Participants in the intervention group had higher self-perception regarding surgical skills after the trial (P = 0.011). Instructor feedback increases the efficiency when training a complex operational task on a virtual reality simulator; time and repetitions used to achieve a predefined proficiency level were significantly reduced in the group that received instructor feedback compared with the control group. NCT01497782.
Zhu, Ming; Liu, Fei; Zhou, Chaozheng; Lin, Li; Zhang, Yan; Chai, Gang; Xie, Le; Qi, Fazhi; Li, Qingfeng
2018-04-11
Augmented reality (AR)-based navigation surgery has evolved to be an advanced assisted technology. The aim of this study is to manifest the accuracy of AR navigation for the intraoperative mandibular angle osteotomy by comparing the navigation with other interventional techniques. A retrospective study was conducted with 93 post-surgical patients with mandibular angle hypertrophy admitted at our plastic and reconstructive surgery department between September 2011 and June 2016. Thirty-one patients received osteotomy conducted using a navigation system based on augmented reality (AR group), 28 patients received osteotomy conducted using individualised templates (IT group) and the remaining 34 patients received osteotomy performed by free hand (free-hand group). The post-operative computed tomography (CT) images were reviewed and analysed by comparing with pre-surgical planning generated by three-dimensional (3D) software. The preparation time, cutting time, whole operating time and discrepancy in osteotomy lines were measured. The preparation time was much shorter for the free-hand group than that for the AR group and the IT group (P < 0.01). However, no significant difference in the whole operating time was observed among the three groups (P > 0.05). In addition, the discrepancy in osteotomy lines was lower for the AR group and in the IT group than for the free-hand group (P < 0.01). The navigation system based on AR has a higher accuracy, more reliability and better user friendliness for some particular clinical procedures than for other techniques, which has a promising clinical prospect. Copyright © 2018. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reichelt-Brushett, Amanda J., E-mail: amanda.reich
Artisanal small-scale gold mining (ASGM) using mercury (Hg) amalgamation has been occurring on Buru Island, Indonesia since early 2012, and has caused rapid accumulation of high Hg concentrations in river, estuary and marine sediments. In this study, sediment samples were collected from several sites downstream of the Mount Botak ASGM site, as well as in the vicinity of the more recently established site at Gogrea where no sampling had previously been completed. All sediment samples had total Hg (THg) concentrations exceeding Indonesian sediment quality guidelines and were up to 82 times this limit at one estuary site. The geochemistry ofmore » sediments in receiving environments indicates the potential for Hg-methylation to form highly bioavailable Hg species. To assess the current contamination threat from consumption of local seafood, samples of fish, molluscs and crustaceans were collected from the Namlea fish market and analysed for THg concentrations. The majority of edible tissue samples had elevated THg concentrations, which raises concerns for food safety. This study shows that river, estuary and marine ecosystems downstream of ASGM operations on Buru Island are exposed to dangerously high Hg concentrations, which are impacting aquatic food chains, and fisheries resources. Considering the high dietary dependence on marine protein in the associated community and across the Mollucas Province, and the short time period since ASGM operations commenced in this region, the results warrant urgent further investigation, risk mitigation, and community education. - Highlights: • Mercury contamination of sediments and seafood due to artisanal gold mining. • Considerable risks to human and ecosystem health are identified. • Results emphasise the urgent need for risk mitigation and community education.« less
Alvarez, Katherina; van Leeuwen, Esther; Montenegro-Montenegro, Esteban; van Vugt, Mark
2018-04-01
This field study investigated the consequences of receiving poverty aid through conditional transfer programmes in the form of autonomy-oriented help (i.e., cash) or dependency-oriented help (i.e., vouchers) in impoverished rural communities in Panama. The empowering effects of autonomy- (vs. dependency-) help have so far only been studied in laboratory settings, or in settings where help could easily be refused. Little is known about the reactions of people who rely on help for extended periods of time. This study provides insights into how aid recipients are influenced by the type of aid they receive. Results showed that, as expected, recipients of cash reported more autonomy, empowerment, and life improvements than recipients of vouchers. Training, another type of autonomy-oriented help, was positively related to empowerment, personal, and family change beliefs. These findings illustrate the benefits of autonomy-oriented help programmes in empowering people from extremely poor communities around the world, who rely on aid for extended periods of time. © 2018 The Authors. British Journal of Social Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2014 CFR
2014-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2012 CFR
2012-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2013 CFR
2013-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2011 CFR
2011-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2010 CFR
2010-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
Hasegawa, Kunihiro; Takata, Ryo; Nishikawa, Hiroki; Enomoto, Hirayuki; Ishii, Akio; Iwata, Yoshinori; Miyamoto, Yuho; Ishii, Noriko; Yuri, Yukihisa; Nakano, Chikage; Nishimura, Takashi; Yoh, Kazunori; Aizawa, Nobuhiro; Sakai, Yoshiyuki; Ikeda, Naoto; Takashima, Tomoyuki; Iijima, Hiroko; Nishiguchi, Shuhei
2016-09-12
We aimed to examine the effect of Wisteria floribunda agglutinin-positive Mac-2-binding protein (WFA⁺-M2BP) level on survival comparing with other laboratory liver fibrosis markers in hepatitis C virus (HCV)-related compensated liver cirrhosis (LC) (n = 165). For assessing prognostic performance of continuous fibrosis markers, we adapted time-dependent receiver operating characteristics (ROC) curves for clinical outcome. In time-dependent ROC analysis, annual area under the ROCs (AUROCs) were plotted. We also calculated the total sum of AUROCs in all time-points (TAAT score) in each fibrosis marker. WFA⁺-M2BP value ranged from 0.66 cutoff index (COI) to 19.95 COI (median value, 5.29 COI). Using ROC analysis for survival, the optimal cutoff point for WFA⁺-M2BP was 6.15 COI (AUROC = 0.79348, sensitivity = 80.0%, specificity = 74.78%). The cumulative five-year survival rate in patients with WFA⁺-M2BP ≥ 6.15 COI (n = 69) was 43.99%, while that in patients with WFA⁺-M2BP < 6.15 COI (n = 96) was 88.40% (p < 0.0001). In the multivariate analysis, absence of hepatocellular carcinoma (p = 0.0008), WFA⁺-M2BP < 6.15 COI (p = 0.0132), achievement of sustained virological response (p < 0.0001) and des-γ-carboxy prothrombin < 41 mAU/mL (p = 0.0018) were significant favorable predictors linked to survival. In time-dependent ROC analysis in all cases, WFA⁺-M2BP had the highest TAAT score among liver fibrosis markers. In conclusion, WFA⁺-M2BP can be a useful predictor in HCV-related compensated LC.
Spectral estimation of received phase in the presence of amplitude scintillation
NASA Technical Reports Server (NTRS)
Vilnrotter, V. A.; Brown, D. H.; Hurd, W. J.
1988-01-01
A technique is demonstrated for obtaining the spectral parameters of the received carrier phase in the presence of carrier amplitude scintillation, by means of a digital phased locked loop. Since the random amplitude fluctuations generate time-varying loop characteristics, straightforward processing of the phase detector output does not provide accurate results. The method developed here performs a time-varying inverse filtering operation on the corrupted observables, thus recovering the original phase process and enabling accurate estimation of its underlying parameters.
Dialysate Sodium: Rationale for Evolution over Time
Flythe, Jennifer E.; Mc Causland, Finnian R.
2016-01-01
Oligo-anuric individuals receiving hemodialysis (HD) are dependent on the dialysis machine to regulate sodium and water balance. Interest in adjusting the dialysate sodium concentration to promote tolerance of the HD procedure dates back to the early years of dialysis therapy. Evolution of dialysis equipment technologies and clinical characteristics of the dialysis population have prompted clinicians to increase the dialysate sodium concentration over time. Higher dialysate sodium concentrations generally promote hemodynamic stabilization and reduce intradialytic symptoms but often do so at the expense of stimulating thirst and promoting volume expansion. The opposite may be true for lower dialysate sodium concentrations. Observational data suggest that the association between dialysate sodium and outcomes may differ by serum sodium levels, supporting the trend toward individualization of the dialysate sodium prescription. However, lack of randomized controlled clinical trial data, along with operational safety concerns related to individualized dialysate sodium prescriptions, have prevented expert consensus regarding the optimal approach to the dialysate sodium prescription. PMID:28066913
Optimum quantum receiver for detecting weak signals in PAM communication systems
NASA Astrophysics Data System (ADS)
Sharma, Navneet; Rawat, Tarun Kumar; Parthasarathy, Harish; Gautam, Kumar
2017-09-01
This paper deals with the modeling of an optimum quantum receiver for pulse amplitude modulator (PAM) communication systems. The information bearing sequence {I_k}_{k=0}^{N-1} is estimated using the maximum likelihood (ML) method. The ML method is based on quantum mechanical measurements of an observable X in the Hilbert space of the quantum system at discrete times, when the Hamiltonian of the system is perturbed by an operator obtained by modulating a potential V with a PAM signal derived from the information bearing sequence {I_k}_{k=0}^{N-1}. The measurement process at each time instant causes collapse of the system state to an observable eigenstate. All probabilities of getting different outcomes from an observable are calculated using the perturbed evolution operator combined with the collapse postulate. For given probability densities, calculation of the mean square error evaluates the performance of the receiver. Finally, we present an example involving estimating an information bearing sequence that modulates a quantum electromagnetic field incident on a quantum harmonic oscillator.
The risk of shorter fasting time for pediatric deep sedation.
Clark, Mathew; Birisci, Esma; Anderson, Jordan E; Anliker, Christina M; Bryant, Micheal A; Downs, Craig; Dalabih, Abdallah
2016-01-01
Current guidelines adopted by the American Academy of Pediatrics calls for prolonged fasting times before performing pediatric procedural sedation and analgesia (PSA). PSA is increasingly provided to children outside of the operating theater by sedation trained pediatric providers and does not require airway manipulation. We investigated the safety of a shorter fasting time compared to a longer and guideline compliant fasting time. We tried to identify the association between fasting time and sedation-related complications. This is a prospective observational study that included children 2 months to 18 years of age and had an American Society of Anesthesiologists physical status classification of I or II, who underwent deep sedation for elective procedures, performed by pediatric critical care providers. Procedures included radiologic imaging studies, electroencephalograms, auditory brainstem response, echocardiograms, Botox injections, and other minor surgical procedures. Subjects were divided into two groups depending on the length of their fasting time (4-6 h and >6 h). Complication rates were calculated and compared between the three groups. In the studied group of 2487 subjects, 1007 (40.5%) had fasting time of 4-6 h and the remaining 1480 (59.5%) subjects had fasted for >6 h. There were no statistically significant differences in any of the studied complications between the two groups. This study found no difference in complication rate in regard to the fasting time among our subjects cohort, which included only healthy children receiving elective procedures performed by sedation trained pediatric critical care providers. This suggests that using shorter fasting time may be safe for procedures performed outside of the operating theater that does not involve high-risk patients or airway manipulation.
Overview of engineering activities at the SMA
NASA Astrophysics Data System (ADS)
Christensen, R. D.; Kubo, D. Y.; Rao, Ramprasad
2008-07-01
The Submillmeter Array (SMA) consists of 8 6-meter telescopes on the summit of Mauna Kea. The array has been designed to operate from the summit of Mauna Kea and from 3 remote facilities: Hilo, Hawaii, Cambridge, Massachusetts and Taipei, Taiwan. The SMA provides high-resolution scientific observations in most of the major atmospheric windows from 180 to 700 GHz. Each telescope can house up to 8 receivers in a single cryostat and can operate with one or two receiver bands simultaneously. The array being a fully operational observatory, the demand for science time is extremely high. As a result specific time frames have been set-aside during both the day and night for engineering activities. This ensures that the proper amount of time can be spent on maintaining existing equipment or upgrading the system to provide high quality scientific output during nighttime observations. This paper describes the methods employed at the SMA to optimize engineering development of the telescopes and systems such that the time available for scientific observations is not compromised. It will also examine some of the tools used to monitor the SMA during engineering and science observations both at the site and remote facilities.
Fabrication and installation of the Solar Two central receiver
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litwin, R.Z.; Rogers, R.D.
The heart of the Solar Two power plant is the molten salt central receiver that has been designed, fabricated, and installed over an 18 month schedule. During this time, the receiver system from Solar One was also completely disassembled and removed. The receiver tower structure, for the most part, was left intact because Solar Two was designed to fit this structure such that construction time and costs could be minimized. In order to meet this aggressive schedule, receiver panel fabrication required the parallel production of many components. The sequence for assembly of the four major receiver panel components (i.e., tubes,more » header assembly, strongback, and header oven covers) and key fabrication activities such as welding are described. Once the receiver panels were complete, their installation at the site was begun, and the order in which receiver system components were installed in the tower is described. The completion of the Solar Two receiver proved the fabricability of this important system. However, successful operation of the system at Solar Two is needed to demonstrate the technical feasibility of the molten salt central receiver concept.« less
Solidification of a binary mixture
NASA Technical Reports Server (NTRS)
Antar, B. N.
1982-01-01
The time dependent concentration and temperature profiles of a finite layer of a binary mixture are investigated during solidification. The coupled time dependent Stefan problem is solved numerically using an implicit finite differencing algorithm with the method of lines. Specifically, the temporal operator is approximated via an implicit finite difference operator resulting in a coupled set of ordinary differential equations for the spatial distribution of the temperature and concentration for each time. Since the resulting differential equations set form a boundary value problem with matching conditions at an unknown spatial point, the method of invariant imbedding is used for its solution.
George, Blessy; Wen, Xia; Mercke, Nickie; Gomez, Madeleine; O’Bryant, Cindy; Bowles, Daniel W.; Hu, Yichun; Hogan, Susan L.
2016-01-01
The success of cisplatin-containing regimens to treat solid tumors is limited, in part, by nephrotoxicity. In rodents, several urinary proteins have emerged as more sensitive indicators of cisplatin-induced kidney injury. We sought to characterize time-dependent changes in the urinary concentrations of 12 proteins including KIM-1, calbindin, β2M, and TFF3 after cisplatin therapy. Urine was collected at baseline, 3 (range: 2-5), and 10 (range: 9-11) days from 57 patients with solid tumors receiving outpatient cisplatin therapy (≥ 25 mg/m2). Serum creatinine was largely unchanged after cisplatin infusion. However, compared to baseline values, several novel biomarkers were significantly increased in the urine including β2M, which was 3-fold higher by day 3 (p<0.0001). Urinary KIM-1 and TFF3 were elevated 2-fold by day 10 (p=0.002 and p=0.002, respectively) whereas calbindin levels were increased 8-fold (p<0.0001). We report novel time-dependent changes in the urinary excretion of noninvasive markers of subclinical kidney injury after cisplatin treatment. PMID:28002630
An exact noniterative linear method for locating sources based on measuring receiver arrival times.
Militello, C; Buenafuente, S R
2007-06-01
In this paper an exact, linear solution to the source localization problem based on the time of arrival at the receivers is presented. The method is unique in that the source's position can be obtained by solving a system of linear equations, three for a plane and four for a volume. This simplification means adding an additional receiver to the minimum mathematically required (3+1 in two dimensions and 4+1 in three dimensions). The equations are easily worked out for any receiver configuration and their geometrical interpretation is straightforward. Unlike other methods, the system of reference used to describe the receivers' positions is completely arbitrary. The relationship between this method and previously published ones is discussed, showing how the present, more general, method overcomes nonlinearity and unknown dependency issues.
Synchronisation, acquisition and tracking for telemetry and data reception
NASA Astrophysics Data System (ADS)
Vandoninck, A.
1992-06-01
The important parameters of synchronization, acquisition, and tracking are addressed, and each function is highlighted separately. The following sequence is such as the functions occur in the system in time and for the type of data to be received, with distinction between telemetry and data reception, between direct carrier modulation or the use of a subcarrier, and between deep space and normal reception. For the telemetry reception the acquisition is described taking into account the difference in performances as geostationary or polar orbits, and the dependencies on the different Doppler offsets and rates are distinguished. The related functions and parameters are covered and the specifications of an average receiver are summarized. The synchronization of the valid data is described with a distinction for data directly modulated or via a subcarrier, the type of modulation and bitrate. The relevant functions and parameters of the average receiver/demodulator are summarized. The tracking of the signal in the course of the operational phase is described and relevant parameters of an actual system are presented. The reception of real data is handled and a sequence of acquisition, synchronization, and tracking is applied. Here higher bitrates and direct modulation schemes play an important role. The market equipment with the relevant parameters are discussed. The three functions in cases where deep reception is needed are covered. The high performance receiver/demodulator functions and how the acquisition, synchronization, and tracking is handled in such application, are explained.
Airborne polarimetric Doppler weather radar: trade-offs between various engineering specifications
NASA Astrophysics Data System (ADS)
Vivekanandan, Jothiram; Loew, Eric
2018-01-01
NCAR EOL is investigating potential configurations for the next-generation airborne phased array radar (APAR) that is capable of retrieving dynamic and microphysical characteristics of clouds and precipitation. The APAR will operate at C band. The APAR will use the electronic scanning (e-scan) feature to acquire the optimal number of independent samples for recording research-quality measurements. Since the airborne radar has only a limited time for collecting measurements over a specified region (moving aircraft platform ˜ 100 m s-1), beam multiplexing will significantly enhance its ability to collect high-resolution, research-quality measurements. Beam multiplexing reduces errors in radar measurements while providing rapid updates of scan volumes. Beamwidth depends on the size of the antenna aperture. Beamwidth and directivity of elliptical, circular, and rectangular antenna apertures are compared and radar sensitivity is evaluated for various polarimetric configurations and transmit-receive (T/R) elements. In the case of polarimetric measurements, alternate transmit with alternate receive (single-channel receiver) and simultaneous reception (dual-channel receiver) is compared. From an overall architecture perspective, element-level digitization of T/R module versus digital sub-array is considered with regard to flexibility in adaptive beamforming, polarimetric performance, calibration, and data quality. Methodologies for calibration of the radar and removing bias in polarimetric measurements are outlined. The above-mentioned engineering options are evaluated for realizing an optimal APAR system suitable for measuring the high temporal and spatial resolutions of Doppler and polarimetric measurements of precipitation and clouds.
31 CFR 101.3 - Petitions reviewed by Assistant Secretary, Enforcement, Operations, Tariff Affairs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... time of submission or thereafter; (3) The coins are not needed and will not be needed in the future in... reviewed by Assistant Secretary, Enforcement, Operations, Tariff Affairs. (a) The Assistant Secretary will receive and review all petitions for mitigation of the forfeiture of counterfeit gold coins. He shall...
Real-time differential GPS/GLONASS trials in Europe using all-in-view 20-channel receivers
NASA Astrophysics Data System (ADS)
Capaccio, S.; Lowe, D.; Walsh, D. M. A.; Daly, P.
Following the initial development of 20-channel, all-in-view Global Navigation Satellite System (GNSS), GPS/GLONASS/Inmarsat-3, receivers at the Institute of Satellite Navigation (ISN), University of Leeds, a modification programme has been undertaken to allow real-time differential corrections to be sent from one 20-channel receiver to another identical receiver using a serial link between them. The differential correction software incorporates the RTCM SC-104 and RTCA DO-217 format developed specifically for GPS and adjusted by the ISN to allow simultaneous GLONASS operation.After successful laboratory testing, real-time differential GNSS tests were successfully completed in static mode between Aberdeen and Leeds via the SkyFix differential data-link, and in dynamic mode at DTEO Boscombe Down using a C-band data-link between the ground and a receiver on board the DRA BAC 1-11 aircraft. The aims of the tests were, (i) to demonstrate real-time differential GNSS position-fixing, (ii) to establish the accuracy improvements brought about, and (iii) to examine the effects of data-link latency and satellite PDOP on the solution accuracy.
An Assessment of Operational Energy Capability Improvement Fund (OECIF) Programs 17-S-2544
2017-09-19
persistently attack key operational energy problems . OECIF themes are summarized in Table 1, and Appendix A includes more detail on the programs within... problems FY 2014 Analytical methods and tools FY 2015 Improving fuel economy for the current tactical ground fleet FY 2016 Increasing the operational...involve a variety of organizations to solve operational energy problems . In FY 2015, the OECIF program received a one-time $14.1M Congressional plus-up
Load-induced modulation of signal transduction networks.
Jiang, Peng; Ventura, Alejandra C; Sontag, Eduardo D; Merajver, Sofia D; Ninfa, Alexander J; Del Vecchio, Domitilla
2011-10-11
Biological signal transduction networks are commonly viewed as circuits that pass along information--in the process amplifying signals, enhancing sensitivity, or performing other signal-processing tasks--to transcriptional and other components. Here, we report on a "reverse-causality" phenomenon, which we call load-induced modulation. Through a combination of analytical and experimental tools, we discovered that signaling was modulated, in a surprising way, by downstream targets that receive the signal and, in doing so, apply what in physics is called a load. Specifically, we found that non-intuitive changes in response dynamics occurred for a covalent modification cycle when load was present. Loading altered the response time of a system, depending on whether the activity of one of the enzymes was maximal and the other was operating at its minimal rate or whether both enzymes were operating at submaximal rates. These two conditions, which we call "limit regime" and "intermediate regime," were associated with increased or decreased response times, respectively. The bandwidth, the range of frequency in which the system can process information, decreased in the presence of load, suggesting that downstream targets participate in establishing a balance between noise-filtering capabilities and a circuit's ability to process high-frequency stimulation. Nodes in a signaling network are not independent relay devices, but rather are modulated by their downstream targets.
The costs and quality of operative training for residents in tympanoplasty type I.
Wang, Mao-Che; Yu, Eric Chen-Hua; Shiao, An-Suey; Liao, Wen-Huei; Liu, Chia-Yu
2009-05-01
A teaching hospital would incur more operation room costs on training surgical residents. To evaluate the increased operation time and the increased operation room costs of operations performed by surgical residents. As a model we used a very common surgical otology procedure -- tympanoplasty type I. From January 1, 2004 to December 31, 2004, we included in this study 100 patients who received tympanoplasty type I in Taipei Veterans General Hospital. Fifty-six procedures were performed by a single board-certified surgeon and 44 procedures were performed by residents. We analyzed the operation time and surgical outcomes in these two groups of patients. The operation room cost per minute was obtained by dividing the total operation room expenses by total operation time in the year 2004. The average operation time of residents was 116.47 min, which was significantly longer (p<0.0001) than that of the board-certified surgeon (average 81.07 min). It cost USD $40.36 more for each operation performed by residents in terms of operation room costs. The surgical success rate of residents was 81.82%, which was significantly lower (p=0.016) than that of the board-certified surgeon (96.43%).
Food-deprivation effects on punished schedule-induced drinking in rats.
Lamas, E; Pellón, R
1995-01-01
Food-deprived rats (at 80% of their free-feeding weights) were exposed to a fixed-time 60-s schedule of food-pellet presentation and developed schedule-induced drinking. Lick-dependent signaled delays (10 s) to food presentation led to decreased drinking, which recovered when the signaled delays were discontinued. A major effect of this punishment contingency was to increase the proportion of interpellet intervals without any licks. The drinking of yoked control rats, which received food at the same times as those exposed to the signaled delay contingency (masters), was not consistently reduced. When food-deprivation level was changed to 90%, all master and yoked control rats showed decreases in punished or unpunished schedule-induced drinking. When the body weights were reduced to 70%, most master rats increased punished behavior to levels similar to those of unpunished drinking. This effect was not observed for yoked controls. Therefore, body-weight loss increased the resistance of schedule-induced drinking to reductions by punishment. Food-deprivation effects on punished schedule-induced drinking are similar to their effects on food-maintained lever pressing. This dependency of punishment on food-deprivation level supports the view that schedule-induced drinking can be modified by the same variables that affect operant behavior in general. PMID:7622981
Viallon, Vivian; Latouche, Aurélien
2011-03-01
Finding out biomarkers and building risk scores to predict the occurrence of survival outcomes is a major concern of clinical epidemiology, and so is the evaluation of prognostic models. In this paper, we are concerned with the estimation of the time-dependent AUC--area under the receiver-operating curve--which naturally extends standard AUC to the setting of survival outcomes and enables to evaluate the discriminative power of prognostic models. We establish a simple and useful relation between the predictiveness curve and the time-dependent AUC--AUC(t). This relation confirms that the predictiveness curve is the key concept for evaluating calibration and discrimination of prognostic models. It also highlights that accurate estimates of the conditional absolute risk function should yield accurate estimates for AUC(t). From this observation, we derive several estimators for AUC(t) relying on distinct estimators of the conditional absolute risk function. An empirical study was conducted to compare our estimators with the existing ones and assess the effect of model misspecification--when estimating the conditional absolute risk function--on the AUC(t) estimation. We further illustrate the methodology on the Mayo PBC and the VA lung cancer data sets. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Path profiles of Cn2 derived from radiometer temperature measurements and geometrical ray tracing
NASA Astrophysics Data System (ADS)
Vyhnalek, Brian E.
2017-02-01
Atmospheric turbulence has significant impairments on the operation of Free-Space Optical (FSO) communication systems, in particular temporal and spatial intensity fluctuations at the receiving aperture resulting in power surges and fades, changes in angle of arrival, spatial coherence degradation, etc. The refractive index structure parameter C 2 n is a statistical measure of the strength of turbulence in the atmosphere and is highly dependent upon vertical height. Therefore to understand atmospheric turbulence effects on vertical FSO communication links such as space-to-ground links, it is necessary to specify C 2 n profiles along the atmospheric propagation path. To avoid the limitations on the applicability of classical approaches, propagation simulation through geometrical ray tracing is applied. This is achieved by considering the atmosphere along the optical propagation path as a spatial distribution of spherical bubbles with varying relative refractive index deviations representing turbulent eddies. The relative deviations of the refractive index are statistically determined from altitude-dependent and time varying temperature fluctuations, as measured by a microwave profiling radiometer. For each representative atmosphere ray paths are analyzed using geometrical optics, which is particularly advantageous in situations of strong turbulence where there is severe wavefront distortion and discontinuity. The refractive index structure parameter is then determined as a function of height and time.
Path Profiles of Cn2 Derived from Radiometer Temperature Measurements and Geometrical Ray Tracing
NASA Technical Reports Server (NTRS)
Vyhnalek, Brian E.
2017-01-01
Atmospheric turbulence has significant impairments on the operation of Free-Space Optical (FSO) communication systems, in particular temporal and spatial intensity fluctuations at the receiving aperture resulting in power surges and fades, changes in angle of arrival, spatial coherence degradation, etc. The refractive index structure parameter Cn2 is a statistical measure of the strength of turbulence in the atmosphere and is highly dependent upon vertical height. Therefore to understand atmospheric turbulence effects on vertical FSO communication links such as space-to-ground links, it is necessary to specify Cn2 profiles along the atmospheric propagation path. To avoid the limitations on the applicability of classical approaches, propagation simulation through geometrical ray tracing is applied. This is achieved by considering the atmosphere along the optical propagation path as a spatial distribution of spherical bubbles with varying relative refractive index deviations representing turbulent eddies. The relative deviations of the refractive index are statistically determined from altitude-dependent and time-varying temperature fluctuations, as measured by a microwave profiling radiometer. For each representative atmosphere ray paths are analyzed using geometrical optics, which is particularly advantageous in situations of strong turbulence where there is severe wavefront distortion and discontinuity. The refractive index structure parameter is then determined as a function of height and time.
Method for Controlling a Producing Zone of a Well in a Geological Formation
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Amini, B. Jon (Inventor)
2005-01-01
System and methods for transmitting and receiving electromagnetic pulses through a geological formation. A preferably programmable transmitter having an all-digital portion in a preferred embodiment may be operated at frequencies below 1 MHz without loss of target resolution by transmitting and over sampling received long PN codes. A gated and stored portion of the received signal may be correlated with the PN code to determine distances of interfaces within the geological formation, such as the distance of a water interfaces from a wellbore. The received signal is oversampled preferably at rates such as five to fifty times as high as a carrier frequency. In one method of the invention, an oil well with multiple production zones may be kept in production by detecting an approaching water front in one of the production zones and shutting down that particular production zone thereby permitting the remaining production zones to continue operating.
Method for controlling a producing zone of a well in a geological formation
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Amini, B. Jon (Inventor)
2005-01-01
System and methods for transmitting and receiving electromagnetic pulses through a geological formation. A preferably programmable transmitter having an all-digital portion in a preferred embodiment may be operated at frequencies below 1 MHz without loss of target resolution by transmitting and over sampling received long PN codes. A gated and stored portion of the received signal may be correlated with the PN code to determine distances of interfaces within the geological formation, such as the distance of a water interfaces from a wellbore. The received signal is oversampled preferably at rates such as five to fifty times as high as a carrier frequency. In one method of the invention, an oil well with multiple production zones may be kept in production by detecting an approaching water front in one of the production zones and shutting down that particular production zone thereby permitting the remaining production zones to continue operating.
Medium Frequency Pseudo Noise Geological Radar
NASA Technical Reports Server (NTRS)
Arndt, G. Dickey (Inventor); Carl, James R. (Inventor); Byerly, Kent A. (Inventor); Amini, B. Jon (Inventor)
2003-01-01
System and methods are disclosed for transmitting and receiving electromagnetic pulses through a geological formation. A preferably programmable transmitter having an all-digital portion in a preferred embodiment may be operated at frequencies below 1 MHz without loss of target resolution by transmitting and over sampling received long PN codes. A gated and stored portion of the received signal may be correlated with the PN code to determine distances of interfaces within the geological formation, such as the distance of a water interfaces from a wellbore. The received signal is oversampled preferably at rates such as five to fifty times as high as a carrier frequency. In one method of the invention, an oil well with multiple production zones may be kept in production by detecting an approaching water front in one of the production zones and shutting down that particular production zone thereby permitting the remaining production zones to continue operating.
Flores, P; Pellón, R
1998-03-01
Food deprived Wistar rats were exposed to a fixed time 60 s food schedule until they developed schedule-induced polydipsia. Rats were matched in pairs according to their licking rate, being designated experimental or yoked control at random. Every fifth lick by experimental rats was then followed by an electric shock (0.05, 0.1, or 0.2 mA) while the food schedule continued in operation. Yoked-control rats received the same shocks as experimental rats, but independently of their own licking. Drugs were then tested on the suppressed rates of licking. Diazepam (0.5-2.0 mg/kg) increased punished schedule-induced polydipsia, a result not observed in yoked controls. No increases in the licks per minute of experimental or control animals were found after d-amphetamine (0.25-4.0 mg/kg) or buspirone (0.5-8.0 mg/kg). In comparison with previous results it is concluded that the antipunishment effects of drugs on schedule-induced behaviour depend on the type of punishment contingency.
20 CFR 404.360 - When a child is dependent upon the insured person.
Code of Federal Regulations, 2010 CFR
2010-04-01
... person. 404.360 Section 404.360 Employees' Benefits SOCIAL SECURITY ADMINISTRATION FEDERAL OLD-AGE... you received contributions for your support from the insured, or that the insured provided at least one-half of your support. These dependency requirements, and the time at which they must be met, are...
Shi, Fujun; Huang, Zonghai; Yu, Jinlong; Zhang, Pusheng; Deng, Jianwen; Zou, Linhan; Zhang, Cheng; Luo, Yunfeng
2017-01-31
Endoscopic axillary lymphadenectomy (EALND) was introduced to clinical work to reduce side effects of conventional axillary lymphadenectomy, while the lipolysis and liposuction of EALND made the process consume more time. The aim of the study was to determine whether immediate liposuction after tumescent solution injection to the axilla could shorten the total time of EALND. Fifty-nine patients were enrolled in the study, 30 of them received EALND with traditional liposuction method (TLM), and the rest 29 patients received EALND with immediate liposuction method (ILM). The operation time, cosmetic result, drainage amount, and hospitalization time of the two groups were compared. The median EALND operation time of TLM group and ILM group were 68 and 46 min, respectively, the difference was significant (P < 0.05); the median cosmetic results of the two groups were 6.6 and 6.4, respectively; the median drainage amount of the two groups were 366 and 385 ml, respectively; the hospitalization time of the two groups were 15 and 16 days, respectively. For the last three measures, no significant difference was confirmed (P > 0.05). Our work suggests immediate liposuction could shorten the endoscopic axillary lymphadenectomy process, and this method would not compromise the operation results. However, due to the limitations of the research, more work needs to be done to prove the availability and feasibility of immediate liposuction.
Bayesian Inference for Time Trends in Parameter Values using Weighted Evidence Sets
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. L. Kelly; A. Malkhasyan
2010-09-01
There is a nearly ubiquitous assumption in PSA that parameter values are at least piecewise-constant in time. As a result, Bayesian inference tends to incorporate many years of plant operation, over which there have been significant changes in plant operational and maintenance practices, plant management, etc. These changes can cause significant changes in parameter values over time; however, failure to perform Bayesian inference in the proper time-dependent framework can mask these changes. Failure to question the assumption of constant parameter values, and failure to perform Bayesian inference in the proper time-dependent framework were noted as important issues in NUREG/CR-6813, performedmore » for the U. S. Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards in 2003. That report noted that “in-dustry lacks tools to perform time-trend analysis with Bayesian updating.” This paper describes an applica-tion of time-dependent Bayesian inference methods developed for the European Commission Ageing PSA Network. These methods utilize open-source software, implementing Markov chain Monte Carlo sampling. The paper also illustrates an approach to incorporating multiple sources of data via applicability weighting factors that address differences in key influences, such as vendor, component boundaries, conditions of the operating environment, etc.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dana L. Kelly; Albert Malkhasyan
2010-06-01
There is a nearly ubiquitous assumption in PSA that parameter values are at least piecewise-constant in time. As a result, Bayesian inference tends to incorporate many years of plant operation, over which there have been significant changes in plant operational and maintenance practices, plant management, etc. These changes can cause significant changes in parameter values over time; however, failure to perform Bayesian inference in the proper time-dependent framework can mask these changes. Failure to question the assumption of constant parameter values, and failure to perform Bayesian inference in the proper time-dependent framework were noted as important issues in NUREG/CR-6813, performedmore » for the U. S. Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards in 2003. That report noted that “industry lacks tools to perform time-trend analysis with Bayesian updating.” This paper describes an application of time-dependent Bayesian inference methods developed for the European Commission Ageing PSA Network. These methods utilize open-source software, implementing Markov chain Monte Carlo sampling. The paper also illustrates the development of a generic prior distribution, which incorporates multiple sources of generic data via weighting factors that address differences in key influences, such as vendor, component boundaries, conditions of the operating environment, etc.« less
Synchronizing compute node time bases in a parallel computer
Chen, Dong; Faraj, Daniel A; Gooding, Thomas M; Heidelberger, Philip
2015-01-27
Synchronizing time bases in a parallel computer that includes compute nodes organized for data communications in a tree network, where one compute node is designated as a root, and, for each compute node: calculating data transmission latency from the root to the compute node; configuring a thread as a pulse waiter; initializing a wakeup unit; and performing a local barrier operation; upon each node completing the local barrier operation, entering, by all compute nodes, a global barrier operation; upon all nodes entering the global barrier operation, sending, to all the compute nodes, a pulse signal; and for each compute node upon receiving the pulse signal: waking, by the wakeup unit, the pulse waiter; setting a time base for the compute node equal to the data transmission latency between the root node and the compute node; and exiting the global barrier operation.
Synchronizing compute node time bases in a parallel computer
Chen, Dong; Faraj, Daniel A; Gooding, Thomas M; Heidelberger, Philip
2014-12-30
Synchronizing time bases in a parallel computer that includes compute nodes organized for data communications in a tree network, where one compute node is designated as a root, and, for each compute node: calculating data transmission latency from the root to the compute node; configuring a thread as a pulse waiter; initializing a wakeup unit; and performing a local barrier operation; upon each node completing the local barrier operation, entering, by all compute nodes, a global barrier operation; upon all nodes entering the global barrier operation, sending, to all the compute nodes, a pulse signal; and for each compute node upon receiving the pulse signal: waking, by the wakeup unit, the pulse waiter; setting a time base for the compute node equal to the data transmission latency between the root node and the compute node; and exiting the global barrier operation.
[Effects of electroacupuncture preemptive intervention on postoperative pain of mixed hemorrhoids].
Wu, Jing; Zhao, Yu; Yang, Chun-Mei; Xue, Qi-Ming; Li, Ning
2014-03-01
To evaluate clinical efficacy of electroacupuncture at Changqiang (GV 1) and Chengshan (BL 57) 30 min before surgery on postoperative pain and discomforts in patients with mixed hemorrhoids. One hundred and twenty cases of mixed hemorrhoids who received Milligan-Morgan operation were randomly divided into an electroacupuncture group, a sham electroacupuncture group and a blank group, 40 cases in each one. At the same time of basic treatment, the electroacupuncture was applied at Changqiang (GV 1) and Chengshan (BL 57) 30 min before surgery in the electroacupuncture group, while shallow needling without electrical stimulation at sham acupoint (1 cm next to acupoint) was applied 30 min before surgery in the sham electroacupuncture group, while no treatment was given before the surgery in the blank group. The total dose of painkillers in the first 24 h after operation, the number of cases who received additional anesthetic in the operation, the self-score of most severity pain in the first 24 h after operation and sleeping time in the night of surgery were observed. The differences of the numbers of cases who received additional anesthetic in the operation had no statistical significance among the three groups (all P > 0.05), but compared with the sham electroacupuncture group and blank group, the total dose of painkillers in the first 24 h after operation was reduced in the electroacupuncture group [(2.43 +/- 1.08) tablets vs (3.23 +/- 1.33) tablets, (3.10 +/- 1.22) tablets], and the score of most severity pain was also decreased (6.65 +/- 1.00 vs 7.48 +/- 0.96, 7.25 +/- 1.19), besides, the sleeping time in the night of surgery was increased [(220.63 +/- 85.50) min vs (162.00 +/- 92.69) min, (151.50 +/- 80.01) min, all P < 0.05]. The electroacupuncture at Changqiang (GV 1) and Chengshan (BL 57) 30 min before surgery has effects of preemptive analgesia on postoperative pain for patients with mixed hemorrhoids.
Interactive signal analysis and ultrasonic data collection system user's manual
NASA Technical Reports Server (NTRS)
Smith, G. R.
1978-01-01
The interactive signal analysis and ultrasonic data collection system (ECHO1) is a real time data acquisition and display system. ECHO1 executed on a PDP-11/45 computer under the RT11 real time operating system. Extensive operator interaction provided the requisite parameters to the data collection, calculation, and data modules. Data were acquired in real time from a pulse echo ultrasonic system using a Biomation Model 8100 transient recorder. The data consisted of 2084 intensity values representing the amplitude of pulses transmitted and received by the ultrasonic unit.
Dawes, Timothy J W; de Marvao, Antonio; Shi, Wenzhe; Fletcher, Tristan; Watson, Geoffrey M J; Wharton, John; Rhodes, Christopher J; Howard, Luke S G E; Gibbs, J Simon R; Rueckert, Daniel; Cook, Stuart A; Wilkins, Martin R; O'Regan, Declan P
2017-05-01
Purpose To determine if patient survival and mechanisms of right ventricular failure in pulmonary hypertension could be predicted by using supervised machine learning of three-dimensional patterns of systolic cardiac motion. Materials and Methods The study was approved by a research ethics committee, and participants gave written informed consent. Two hundred fifty-six patients (143 women; mean age ± standard deviation, 63 years ± 17) with newly diagnosed pulmonary hypertension underwent cardiac magnetic resonance (MR) imaging, right-sided heart catheterization, and 6-minute walk testing with a median follow-up of 4.0 years. Semiautomated segmentation of short-axis cine images was used to create a three-dimensional model of right ventricular motion. Supervised principal components analysis was used to identify patterns of systolic motion that were most strongly predictive of survival. Survival prediction was assessed by using difference in median survival time and area under the curve with time-dependent receiver operating characteristic analysis for 1-year survival. Results At the end of follow-up, 36% of patients (93 of 256) died, and one underwent lung transplantation. Poor outcome was predicted by a loss of effective contraction in the septum and free wall, coupled with reduced basal longitudinal motion. When added to conventional imaging and hemodynamic, functional, and clinical markers, three-dimensional cardiac motion improved survival prediction (area under the receiver operating characteristic curve, 0.73 vs 0.60, respectively; P < .001) and provided greater differentiation according to difference in median survival time between high- and low-risk groups (13.8 vs 10.7 years, respectively; P < .001). Conclusion A machine-learning survival model that uses three-dimensional cardiac motion predicts outcome independent of conventional risk factors in patients with newly diagnosed pulmonary hypertension. Online supplemental material is available for this article.
Stroh, C; Wilhelm, B; Weiner, R; Ludwig, K; Benedix, F; Knoll, C; Lippert, H; Manger, T; Adipositas, Kompetenznetz
2016-02-01
Since January 2005, the situation of metabolic and obesity surgery in Germany has been constantly evaluated by the German Bariatric Surgery Registry (GBSR). Data registration is performed using an internet online database with prospective data collection. All registered data were analysed in cooperation with the Institute of Quality Assurance at the Otto-von-Guericke University Magdeburg. Data collection includes primary and revision/redo-procedures. A main focus of the current study is the analysis of data regarding the perioperative management, in particular, administration of antibiotics. Since 2005 a significant increase of primary bariatric procedures has been reported. For evaluation of the antibiotic regimen 12 296 primary operations including 684 balloons (BIB), 2950 gastric bandings (GB), 5115 Roux-en-Y-gastric bypasses (RYGBP), 120 Scopinaro's biliopancreatic diversions (BPD), 164 duodenal switches (DS), 3125 sleeve gastrectomies (SG) and 138 other procedures were analysed. In total 77.3 % of the patients with primary procedures received perioperative antibiotics. Patients without concomitant comorbidities received antibiotics significantly less often compared to those with comorbidities. Wound infection rates were comparable for patients who underwent either gastric banding or sleeve gastrectomy. Surgery has been accepted step by step as a treatment for morbid obesity and its comorbidities in Germany during the last few years. There is only little experience in the literature regarding antibiotic therapy as well as prophylaxis in bariatric surgery. Based on the results of the current study we recommend rather the selective than the routine use of antibiotics depending on different parameters, e.g., operative time, preoperative BMI and concomitant comorbidities. Georg Thieme Verlag KG Stuttgart · New York.
Karakaya, Jale; Karabulut, Erdem; Yucel, Recai M.
2015-01-01
Modern statistical methods using incomplete data have been increasingly applied in a wide variety of substantive problems. Similarly, receiver operating characteristic (ROC) analysis, a method used in evaluating diagnostic tests or biomarkers in medical research, has also been increasingly popular problem in both its development and application. While missing-data methods have been applied in ROC analysis, the impact of model mis-specification and/or assumptions (e.g. missing at random) underlying the missing data has not been thoroughly studied. In this work, we study the performance of multiple imputation (MI) inference in ROC analysis. Particularly, we investigate parametric and non-parametric techniques for MI inference under common missingness mechanisms. Depending on the coherency of the imputation model with the underlying data generation mechanism, our results show that MI generally leads to well-calibrated inferences under ignorable missingness mechanisms. PMID:26379316
47 CFR 74.1263 - Time of operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., AUXILIARY, SPECIAL BROADCAST AND OTHER PROGRAM DISTRIBUTIONAL SERVICES FM Broadcast Translator Stations and FM Broadcast Booster Stations § 74.1263 Time of operation. (a) The licensee of an FM translator or... an FM translator or booster station is expected to provide a dependable service to the extent that...
NASA Astrophysics Data System (ADS)
Yi, Gong; Jilin, Cheng; Lihua, Zhang; Rentian, Zhang
2010-06-01
According to different processes of tides and peak-valley electricity prices, this paper determines the optimal start up time in pumping station's 24 hours operation between the rating state and adjusting blade angle state respectively based on the optimization objective function and optimization model for single-unit pump's 24 hours operation taking JiangDu No.4 Pumping Station for example. In the meantime, this paper proposes the following regularities between optimal start up time of pumping station and the process of tides and peak-valley electricity prices each day within a month: (1) In the rating and adjusting blade angle state, the optimal start up time in pumping station's 24 hours operation which depends on the tide generation at the same day varies with the process of tides. There are mainly two kinds of optimal start up time which include the time at tide generation and 12 hours after it. (2) In the rating state, the optimal start up time on each day in a month exhibits a rule of symmetry from 29 to 28 of next month in the lunar calendar. The time of tide generation usually exists in the period of peak electricity price or the valley one. The higher electricity price corresponds to the higher minimum cost of water pumping at unit, which means that the minimum cost of water pumping at unit depends on the peak-valley electricity price at the time of tide generation on the same day. (3) In the adjusting blade angle state, the minimum cost of water pumping at unit in pumping station's 24 hour operation depends on the process of peak-valley electricity prices. And in the adjusting blade angle state, 4.85%˜5.37% of the minimum cost of water pumping at unit will be saved than that of in the rating state.
Direct memory access transfer completion notification
Archer, Charles J. , Blocksome; Michael A. , Parker; Jeffrey, J [Rochester, MN
2011-02-15
Methods, systems, and products are disclosed for DMA transfer completion notification that include: inserting, by an origin DMA on an origin node in an origin injection FIFO, a data descriptor for an application message; inserting, by the origin DMA, a reflection descriptor in the origin injection FIFO, the reflection descriptor specifying a remote get operation for injecting a completion notification descriptor in a reflection injection FIFO on a reflection node; transferring, by the origin DMA to a target node, the message in dependence upon the data descriptor; in response to completing the message transfer, transferring, by the origin DMA to the reflection node, the completion notification descriptor in dependence upon the reflection descriptor; receiving, by the origin DMA from the reflection node, a completion packet; and notifying, by the origin DMA in response to receiving the completion packet, the origin node's processing core that the message transfer is complete.
An analysis of power beaming for the Moon and Mars
NASA Technical Reports Server (NTRS)
Stavnes, Mark W.
1992-01-01
Operations on the surface of the Moon and Mars will depend on a reliable source of electrical power. At NASA Lewis Research Center, the feasibility of powering lunar and Martian surface sites by power beaming was studied. Constellations of nuclear or solar powered satellites using microwave or laser transmitters were designed to power an equatorial surface base. Additional surface assets, such as rovers, can also be powered from the same orbiting satellites, requiring only the additional mass of a receiver. However, the actual mass and power capabilities of the system are dependent on the location of the surface receiver. The masses of the beam power systems can be reduced by up to 50 percent, by using the power source of an electric propulsion vehicle to power the beam system. The important analyses results and any additional issues that remain unresolved are discussed.
Validation results of the IAG Dancer project for distributed GPS analysis
NASA Astrophysics Data System (ADS)
Boomkamp, H.
2012-12-01
The number of permanent GPS stations in the world has grown far too large to allow processing of all this data at analysis centers. The majority of these GPS sites do not even make their observation data available to the analysis centers, for various valid reasons. The current ITRF solution is still based on centralized analysis by the IGS, and subsequent densification of the reference frame via regional network solutions. Minor inconsistencies in analysis methods, software systems and data quality imply that this centralized approach is unlikely to ever reach the ambitious accuracy objectives of GGOS. The dependence on published data also makes it clear that a centralized approach will never provide a true global ITRF solution for all GNSS receivers in the world. If the data does not come to the analysis, the only alternative is to bring the analysis to the data. The IAG Dancer project has implemented a distributed GNSS analysis system on the internet in which each receiver can have its own analysis center in the form of a freely distributed JAVA peer-to-peer application. Global parameters for satellite orbits, clocks and polar motion are solved via a distributed least squares solution among all participating receivers. A Dancer instance can run on any computer that has simultaneous access to the receiver data and to the public internet. In the future, such a process may be embedded in the receiver firmware directly. GPS network operators can join the Dancer ITRF realization without having to publish their observation data or estimation products. GPS users can run a Dancer process without contributing to the global solution, to have direct access to the ITRF in near real-time. The Dancer software has been tested on-line since late 2011. A global network of processes has gradually evolved to allow stabilization and tuning of the software in order to reach a fully operational system. This presentation reports on the current performance of the Dancer system, and demonstrates the obvious benefits of distributed analysis of geodetic data in general. IAG Dancer screenshot
NASA Technical Reports Server (NTRS)
Garvin, James B.; Bufton, Jack L.; Cavanaugh, John F.; Krabill, William B.; Clem, Thomas D.; Frederick, Earl B.; Ward, John L.
1991-01-01
Recently, an airborne lidar system that measures laser pulse time-of-flight and the distortion of the pulse waveform upon reflection from earth surface terrain features was developed and is now operational. This instrument is combined with Global Positioning System (GPS) receivers and a two-axis gyroscope for accurate recovery of aircraft position and pointing attitude. The laser altimeter system is mounted on a high-altitude aircraft platform and operated in a repetitively-pulsed mode for measurements of surface elevation profiles at nadir. The laser transmitter makes use of recently developed short-pulse diode-pumped solid-state laser technology in Q-switched Nd:YAG operating at its fundamental wavelength of 1064 nm. A reflector telescope and silicon avalanche photodiode are the basis of the optical receiver. A high-speed time-interval unit and a separate high-bandwidth waveform digitizer under microcomputer control are used to process the backscattered pulses for measurements of terrain. Other aspects of the lidar system are briefly discussed.
Myth Busted: Civilian GPS Receivers Actually do have Access to the L2 Frequency
2010-01-01
2011 2. REPORT TYPE 3. DATES COVERED 00-00-2011 to 00-00-2011 4. TITLE AND SUBTITLE Myth Busted: Civilian GPS Receivers Actually do Have Access...matter experts on Position, Navigation and Timing and on the Global Positioning System ( GPS ) constellation. In the course of educat- ing FA40s in...the Space Operations Officer Qualification Course, in less than three months, students receive as many as six briefs dealing with GPS . These briefs
Assessment of human exposure doses received by activation of medical linear accelerator components
NASA Astrophysics Data System (ADS)
Lee, D.-Y.; Kim, J.-H.; Park, E.-T.
2017-08-01
This study analyzes the radiation exposure dose that an operator can receive from radioactive components during maintenance or repair of a linear accelerator. This study further aims to evaluate radiological safety. Simulations are performed on 10 MV and 15 MV photon beams, which are the most frequently used high-energy beams in clinics. The simulation analyzes components in order of activity and the human exposure dose based on the amount of neutrons received. As a result, the neutron dose, radiation dose, and human exposure dose are ranked in order of target, primary collimator, flattening filter, multi-leaf collimator, and secondary collimator, where the minimum dose is 9.34E-07 mSv/h and the maximum is 1.71E-02 mSv/h. When applying the general dose limit (radiation worker 20 mSv/year, pubic 1 mSv/year) in accordance with the Nuclear Safety Act, all components of a linear accelerator are evaluated as below the threshold value. Therefore, the results suggest that there is no serious safety issue for operators in maintaining and repairing a linear accelerator. Nevertheless, if an operator recognizes an exposure from the components of a linear accelerator during operation and considers the operating time and shielding against external exposure, exposure of the operator is expected to be minimized.
SDR implementation of the receiver of adaptive communication system
NASA Astrophysics Data System (ADS)
Skarzynski, Jacek; Darmetko, Marcin; Kozlowski, Sebastian; Kurek, Krzysztof
2016-04-01
The paper presents software implementation of a receiver forming a part of an adaptive communication system. The system is intended for communication with a satellite placed in a low Earth orbit (LEO). The ability of adaptation is believed to increase the total amount of data transmitted from the satellite to the ground station. Depending on the signal-to-noise ratio (SNR) of the received signal, adaptive transmission is realized using different transmission modes, i.e., different modulation schemes (BPSK, QPSK, 8-PSK, and 16-APSK) and different convolutional code rates (1/2, 2/3, 3/4, 5/6, and 7/8). The receiver consists of a software-defined radio (SDR) module (National Instruments USRP-2920) and a multithread reception software running on Windows operating system. In order to increase the speed of signal processing, the software takes advantage of single instruction multiple data instructions supported by x86 processor architecture.
Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M
2002-01-01
The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.
Epstein, Nancy E
2010-04-07
To determine whether patients who become quadriplegic following cervical spine surgery are adequately compensated by our present medico-legal system. The outcomes of malpractice suits obtained from Verdict Search (East Islip, NY, USA), a medico-legal journal, were evaluated over a 20-year period. Although the present malpractice system generously rewards many quadriplegic patients with substantial settlements/ Plaintiffs' verdicts, a subset receive lesser reimbursements (verdicts/settlements], while others with defense verdicts receive no compensatory damages. Utilizing Verdict Search, 54 cases involving quadriplegia following cervical spine surgery were reviewed for a 20-year interval (1988-2008). The reason(s) for the suit, the defendants, the legal outcome, and the time to outcome were identified. Operations included 25 anterior cervical procedures, 22 posterior cervical operations, 1 circumferential cervical procedure, and 6 cases in which the cervical operations were not defined. The four most prominent legal allegations for suits included negligent surgery (47 cases), lack of informed consent (23 cases), failure to diagnose/treat (33 cases), and failure to brace (15 cases). Forty-four of the 54 suits included spine surgeons. There were 19 Plaintiffs' verdicts (average US $5.9 million, range US $540,000-US $18.4 million), and 20 settlements (average US $2.8 million, range US $66,500-US $12.0 million). Fifteen quadriplegic patients with defense verdicts received no compensatory damages. The average time to verdicts/settlements was 4.3 years. For 54 patients who were quadriplegic following cervical spine surgery, 15 (28%) with defense verdicts received no compensatory damages. Under a No-Fault system, quadriplegic patients would qualify for a "reasonable" level of compensation over a "shorter" time frame.
Guyennon, Nicolas; Cerretto, Giancarlo; Tavella, Patrizia; Lahaye, François
2009-08-01
In recent years, many national timing laboratories have installed geodetic Global Positioning System receivers together with their traditional GPS/GLONASS Common View receivers and Two Way Satellite Time and Frequency Transfer equipment. Many of these geodetic receivers operate continuously within the International GNSS Service (IGS), and their data are regularly processed by IGS Analysis Centers. From its global network of over 350 stations and its Analysis Centers, the IGS generates precise combined GPS ephemeredes and station and satellite clock time series referred to the IGS Time Scale. A processing method called Precise Point Positioning (PPP) is in use in the geodetic community allowing precise recovery of GPS antenna position, clock phase, and atmospheric delays by taking advantage of these IGS precise products. Previous assessments, carried out at Istituto Nazionale di Ricerca Metrologica (INRiM; formerly IEN) with a PPP implementation developed at Natural Resources Canada (NRCan), showed PPP clock solutions have better stability over short/medium term than GPS CV and GPS P3 methods and significantly reduce the day-boundary discontinuities when used in multi-day continuous processing, allowing time-limited, campaign-style time-transfer experiments. This paper reports on follow-on work performed at INRiM and NRCan to further characterize and develop the PPP method for time transfer applications, using data from some of the National Metrology Institutes. We develop a processing procedure that takes advantage of the improved stability of the phase-connected multi-day PPP solutions while allowing the generation of continuous clock time series, more applicable to continuous operation/monitoring of timing equipment.
Interferometric synthetic aperture radar imagery of the Gulf Stream
NASA Technical Reports Server (NTRS)
Ainsworth, T. L.; Cannella, M. E.; Jansen, R. W.; Chubb, S. R.; Carande, R. E.; Foley, E. W.; Goldstein, R. M.; Valenzuela, G. R.
1993-01-01
The advent of interferometric synthetic aperture radar (INSAR) imagery brought to the ocean remote sensing field techniques used in radio astronomy. Whilst details of the interferometry differ between the two fields, the basic idea is the same: Use the phase information arising from positional differences of the radar receivers and/or transmitters to probe remote structures. The interferometric image is formed from two complex synthetic aperture radar (SAR) images. These two images are of the same area but separated in time. Typically the time between these images is very short -- approximately 50 msec for the L-band AIRSAR (Airborne SAR). During this short period the radar scatterers on the ocean surface do not have time to significantly decorrelate. Hence the two SAR images will have the same amplitude, since both obtain the radar backscatter from essentially the same object. Although the ocean surface structure does not significantly decorrelate in 50 msec, surface features do have time to move. It is precisely the translation of scattering features across the ocean surface which gives rise to phase differences between the two SAR images. This phase difference is directly proportional to the range velocity of surface scatterers. The constant of proportionality is dependent upon the interferometric mode of operation.
Timing of Occurrence Is the Most Important Characteristic of Spot Sign.
Wang, Binli; Yan, Shenqiang; Xu, Mengjun; Zhang, Sheng; Liu, Keqin; Hu, Haitao; Selim, Magdy; Lou, Min
2016-05-01
Most previous studies have used single-phase computed tomographic angiography to detect the spot sign, a marker for hematoma expansion (HE) in spontaneous intracerebral hemorrhage. We investigated whether defining the spot sign based on timing on perfusion computed tomography (CTP) would improve its specificity for predicting HE. We prospectively enrolled supratentorial spontaneous intracerebral hemorrhage patients who underwent CTP within 6 hours of onset. Logistic regression was performed to assess the risk factors for HE and poor outcome. Predictive performance of individual CTP spot sign characteristics were examined with receiver operating characteristic analysis. Sixty-two men and 21 women with spontaneous intracerebral hemorrhage were included in this analysis. Spot sign was detected in 46% (38/83) of patients. Receiver operating characteristic analysis indicated that the timing of spot sign occurrence on CTP had the greatest area under receiver operating characteristic curve for HE (0.794; 95% confidence interval, 0.630-0.958; P=0.007); the cutoff time was 23.13 seconds. On multivariable analysis, the presence of early-occurring spot sign (ie, spot sign before 23.13 seconds) was an independent predictor not only of HE (odds ratio=28.835; 95% confidence interval, 6.960-119.458; P<0.001), but also of mortality at 3 months (odds ratio =22.377; 95% confidence interval, 1.773-282.334; P=0.016). Moreover, the predictive performance showed that the redefined early-occurring spot sign maintained a higher specificity for HE compared with spot sign (91% versus 74%). Redefining the spot sign based on timing of contrast leakage on CTP to determine early-occurring spot sign improves the specificity for predicting HE and 3-month mortality. The use of early-occurring spot sign could improve the selection of ICH patients for potential hemostatic therapy. © 2016 American Heart Association, Inc.
Ionospheric TEC Weather Map Over South America
NASA Astrophysics Data System (ADS)
Takahashi, H.; Wrasse, C. M.; Denardini, C. M.; Pádua, M. B.; de Paula, E. R.; Costa, S. M. A.; Otsuka, Y.; Shiokawa, K.; Monico, J. F. Galera; Ivo, A.; Sant'Anna, N.
2016-11-01
Ionospheric weather maps using the total electron content (TEC) monitored by ground-based Global Navigation Satellite Systems (GNSS) receivers over South American continent, TECMAP, have been operationally produced by Instituto Nacional de Pesquisas Espaciais's Space Weather Study and Monitoring Program (Estudo e Monitoramento Brasileiro de Clima Especial) since 2013. In order to cover the whole continent, four GNSS receiver networks, (Rede Brasileiro de Monitoramento Contínuo) RBMC/Brazilian Institute for Geography and Statistics, Low-latitude Ionospheric Sensor Network, International GNSS Service, and Red Argentina de Monitoreo Satelital Continuo, in total 140 sites, have been used. TECMAPs with a time resolution of 10 min are produced in 12 h time delay. Spatial resolution of the map is rather low, varying between 50 and 500 km depending on the density of the observation points. Large day-to-day variabilities of the equatorial ionization anomaly have been observed. Spatial gradient of TEC from the anomaly trough (total electron content unit, 1 TECU = 1016 el m-2 (TECU) <10) to the crest region (TECU > 80) causes a large ionospheric range delay in the GNSS positioning system. Ionospheric plasma bubbles, their seeding and development, could be monitored. This plasma density (spatial and temporal) variability causes not only the GNSS-based positioning error but also radio wave scintillations. Monitoring of these phenomena by TEC mapping becomes an important issue for space weather concern for high-technology positioning system and telecommunication.
Muzzarelli, Stefano; Meadows, Alison Knauth; Ordovas, Karen Gomes; Higgins, Charles Bernard; Meadows, Jeffery Joshua
2012-03-15
Cardiovascular magnetic resonance (CMR) imaging can predict hemodynamically significant coarctation of the aorta (CoA) with a high degree of discrimination. However, the ability of CMR to predict important clinical outcomes in this patient population is unknown. Therefore, we sought to define the ability of CMR to predict the need for surgical or transcatheter intervention in patients with CoA. We retrospectively reviewed the data from 133 consecutive patients who had undergone CMR for the evaluation of known or suspected CoA. The characteristics of the CMR-derived variables predicting the need for surgical or transcatheter intervention for CoA within 1 year were determined through logistic regression analysis. Therapeutic aortic intervention was performed in 41 (31%) of the 133 patients during the study period. The indexed minimum aortic cross-sectional area was the strongest predictor of subsequent intervention (area under the receiver operating characteristic curve 0.975) followed by heart rate-corrected deceleration time in the descending aorta (area under the receiver operating characteristic curve 0.951), and the percentage of flow increase (area under the receiver operating characteristic curve 0.867). The combination of the indexed minimum aortic cross-sectional area and rate-corrected deceleration time in the descending aorta provided the best predictive model (area under the receiver operating characteristic curve 0.986). In conclusion, CMR findings can predict the need for subsequent intervention in CoA. These findings reinforce the "gate-keeper role" of CMR to cardiac catheterization by providing valuable diagnostic and powerful prognostic information and could guide additional treatment of patients with CoA with the final intent of reducing the number of diagnostic catheterizations in such patients. Copyright © 2012 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
National Center for Educational Statistics (DHEW/OE), Washington, DC.
This statistical report presents the results of a survey of educational services provided by State-operated institutions for delinquent and neglected children. Data was gathered from 257 institutions that received federal assistance under Title I of the Elementary and Secondary Education Act. At the time of the survey, participating institutions…
Nasu, Yusuke; Mizuno, Takayuki; Kasahara, Ryoichi; Saida, Takashi
2011-12-12
To extend the operation wavelength range of dual-polarization optical hybrids (DPOH), we propose a highly symmetrical interferometer design for a polarization beam splitter and an optical hybrid to reduce temperature and wavelength dependence. The design successfully decreases this dependence, and a fabricated DPOH with silica-based planar lightwave circuits provides temperature-insensitive performance with a polarization extinction ratio of over 25 dB and phase errors of less than 3 degrees over the entire C- and L-bands. © 2011 Optical Society of America
NASA Astrophysics Data System (ADS)
Zupančič, B.; Emri, I.
2009-11-01
This is the second paper in the series addressing the constitutive modeling of dynamically loaded elastomeric products such as power transmission belts. During the normal operation of such belts certain segments of the belt structure are loaded via tooth-like cyclical loading. When the time-dependent properties of the elastomeric material “match” the time-scale of the dynamic loading a strain accumulation (incrementation) process occurs. It was shown that the location of a critical rotation speed strongly depends on the distribution (shape) of the retardation spectrum, whereas the magnitude of the accumulated strain is governed by the strength of the corresponding spectrum lines. These interrelations are extremely non-linear. The strain accumulation process is most intensive at the beginning of the drive belt operation, and is less intensive for longer belts. The strain accumulation process is governed by the spectrum lines that are positioned within a certain region, which we call the Strain Accumulation Window (SAW). An SAW is always located to the right of the spectrum line, L i , at log ( ω λ i )=0, where ω is the operational angular velocity. The width of the SAW depends on the width of the material spectrum. Based on the following analysis a new designing criterion is proposed for use in engineering applications for selecting a proper material for general drive-belt operations.
Guo, Jin; Guo, Shuxiang; Tamiya, Takashi; Hirata, Hideyuki; Ishihara, Hidenori
2016-03-01
An Internet-based tele-operative robotic catheter operating system was designed for vascular interventional surgery, to afford unskilled surgeons the opportunity to learn basic catheter/guidewire skills, while allowing experienced physicians to perform surgeries cooperatively. Remote surgical procedures, limited by variable transmission times for visual feedback, have been associated with deterioration in operability and vascular wall damage during surgery. At the patient's location, the catheter shape/position was detected in real time and converted into three-dimensional coordinates in a world coordinate system. At the operation location, the catheter shape was reconstructed in a virtual-reality environment, based on the coordinates received. The data volume reduction significantly reduced visual feedback transmission times. Remote transmission experiments, conducted over inter-country distances, demonstrated the improved performance of the proposed prototype. The maximum error for the catheter shape reconstruction was 0.93 mm and the transmission time was reduced considerably. The results were positive and demonstrate the feasibility of remote surgery using conventional network infrastructures. Copyright © 2015 John Wiley & Sons, Ltd.
Landau problem with time dependent mass in time dependent electric and harmonic background fields
NASA Astrophysics Data System (ADS)
Lawson, Latévi M.; Avossevou, Gabriel Y. H.
2018-04-01
The spectrum of a Hamiltonian describing the dynamics of a Landau particle with time-dependent mass and frequency undergoing the influence of a uniform time-dependent electric field is obtained. The configuration space wave function of the model is expressed in terms of the generalised Laguerre polynomials. To diagonalize the time-dependent Hamiltonian, we employ the Lewis-Riesenfeld method of invariants. To this end, we introduce a unitary transformation in the framework of the algebraic formalism to construct the invariant operator of the system and then to obtain the exact solution of the Hamiltonian. We recover the solutions of the ordinary Landau problem in the absence of the electric and harmonic fields for a constant particle mass.
NASA Technical Reports Server (NTRS)
Kotin, A. D.
1978-01-01
State and local regulation of power plant construction and operation of solar power satellite (SPS) receiving stations is presented. Each receiving antenna station occupies a land area 100-200 km square, receives microwave transmissions from the solar power satellite, and converts them into electricity for transmission to the power grid. The long lead time associated with the SPS and the changing status of state and local regulation dictated emphasis on: generic classification of the types of regulation, and identification of regulatory vectors which affect rectenna facilities.
A universal heliostat control system
NASA Astrophysics Data System (ADS)
Gross, Fabian; Geiger, Mark; Buck, Reiner
2017-06-01
This paper describes the development of a universal heliostat control system as part of the AutoR project [1]. The system can control multiple receivers and heliostat types in a single application. The system offers support for multiple operators on different machines and is designed to be as adaptive as possible. Thus, the system can be used for different heliostat field setups with only minor adaptations of the system's source code. This is achieved by extensive usage of modern programming techniques like reflection and dependency injection. Furthermore, the system features co-simulation of a ray tracer, a reference PID-controller implementation for open volumetric receivers and methods for heliostat calibration and monitoring.
Flight Test Results from Real-Time Relative Global Positioning System Flight Experiment on STS-69
NASA Technical Reports Server (NTRS)
Park, Young W.; Brazzel, Jack P., Jr.; Carpenter, J. Russell; Hinkel, Heather D.; Newman, James H.
1996-01-01
A real-time global positioning system (GPS) Kalman filter has been developed to support automated rendezvous with the International Space Station (ISS). The filter is integrated with existing Shuttle rendezvous software running on a 486 laptop computer under Windows. In this work, we present real-time and postflight results achieved with the filter on STS-69. The experiment used GPS data from an Osborne/Jet propulsion Laboratory TurboRouge receiver carried on the Wake Shield Facility (WSF) free flyer and a Rockwell Collins 3M receiver carried on the Orbiter. Real time filter results, processed onboard the Shuttle and replayed in near-time on the ground, are based on single vehicle mode operation and on 5 to 20 minute snapshots of telemetry provided by WSF for dual-vehicle mode operation. The Orbiter and WSF state vectors calculated using our filter compare favorably with precise reference orbits determined by the University of Texas Center for Space Research. The lessons learned from this experiment will be used in conjunction with future experiments to mitigate the technology risk posed by automated rendezvous and docking to the ISS.
A Tuned-RF Duty-Cycled Wake-Up Receiver with -90 dBm Sensitivity.
Bdiri, Sadok; Derbel, Faouzi; Kanoun, Olfa
2017-12-29
A novel wake-up receiver for wireless sensor networks is introduced. It operates with a modified medium access protocol (MAC), allowing low-energy consumption and practical latency. The ultra-low-power wake-up receiver operates with enhanced duty-cycled listening. The analysis of energy models of the duty-cycle-based communication is presented. All the WuRx blocks are studied to obey the duty-cycle operation. For a mean interval time for the data exchange cycle between a transmitter and a receiver over 1.7 s and a 64-bit wake-up packet detection latency of 32 ms, the average power consumption of the wake-up receiver (WuRx) reaches down to 3 μ W . It also features scalable addressing of more than 512 bit at a data rate of 128 k bit / s -1 . At a wake-up packet error rate of 10 - 2 , the detection sensitivity reaches a minimum of - 90 dBm . The combination of the MAC protocol and the WuRx eases the adoption of different kinds of wireless sensor networks. In low traffic communication, the WuRx dramatically saves more energy than that of a network that is implementing conventional duty-cycling. In this work, a prototype was realized to evaluate the intended performance.
A Tuned-RF Duty-Cycled Wake-Up Receiver with −90 dBm Sensitivity
Derbel, Faouzi; Kanoun, Olfa
2017-01-01
A novel wake-up receiver for wireless sensor networks is introduced. It operates with a modified medium access protocol (MAC), allowing low-energy consumption and practical latency. The ultra-low-power wake-up receiver operates with enhanced duty-cycled listening. The analysis of energy models of the duty-cycle-based communication is presented. All the WuRx blocks are studied to obey the duty-cycle operation. For a mean interval time for the data exchange cycle between a transmitter and a receiver over 1.7 s and a 64-bit wake-up packet detection latency of 32 ms, the average power consumption of the wake-up receiver (WuRx) reaches down to 3 μW. It also features scalable addressing of more than 512 bit at a data rate of 128kbit/s−1. At a wake-up packet error rate of 10−2, the detection sensitivity reaches a minimum of −90 dBm. The combination of the MAC protocol and the WuRx eases the adoption of different kinds of wireless sensor networks. In low traffic communication, the WuRx dramatically saves more energy than that of a network that is implementing conventional duty-cycling. In this work, a prototype was realized to evaluate the intended performance. PMID:29286345
Marine Controlled Source EM Methods: Equipment, Methodology, and Results
NASA Astrophysics Data System (ADS)
Constable, S.; Behrens, J.; Key, K.
2005-12-01
The marine CSEM method has become an important tool for academia and the petroleum industry. Commercially viable seafloor receivers were developed for marine MT exploration over the last decade, but progress in CSEM transmitter design is still at an early stage. We have developed 200~A and 500~A transmitters (Scripps Undersea Electromagnetic Source Instrument, or SUESI-200/500) which operate within the 30~kVA power limitations of academic tow cables. This is done by careful control of antenna impedance (resistance and inductance) and power efficiency. Electrode impedance is largely a function of length, rather than surface area or diameter. The antenna can be made neutrally buoyant by balancing the weight of an aluminum conductor with a thick plastic jacket. Telemetry for control, navigation, and monitoring is overlaid on high voltage power transmission down coaxial tow cables, as an alternative to fiber optic telemetry, allowing use with winches and cables of opportunity. The CSEM noise floor determines the source--receiver ranges, and thus the investigation depths, that can be achieved, and depends on frequency, dipole moment, receiver noise, magnetotelluric interference, and stack time. For typical values, this is 10-15~VA-1m-2. We present examples of data from a sub-salt hydrocarbon prospect in the Gulf of Mexico, and an academic project over the magma chambers of the East Pacific Rise.
Ethylene Control of Anthocyanin Synthesis in Sorghum
Craker, L. E.; Standley, L. A.; Starbuck, M. J.
1971-01-01
Light-induced anthocyanin synthesis in Sorghum vulgare L. seedlings was both promoted and inhibited by ethylene treatment. The rate of anthocyanin formation in sorghum tissue was dependent upon the time of ethylene treatment in relation to light exposure and the stage of the anthocyanin synthesis process. Those plants receiving ethylene treatment during the early lag phase of anthocyanin synthesis had higher anthocyanin content at 24 hours than control plants receiving no ethylene treatment. Plants receiving ethylene treatment after the lag phase had lower anthocyanin content at 24 hours than control plants receiving no ethylene treatment. PMID:16657796
Molecular vibrational states during a collision
NASA Technical Reports Server (NTRS)
Recamier, Jose A.; Jauregui, Rocio
1995-01-01
Alternative algebraic techniques to approximate a given Hamiltonian by a harmonic oscillator are described both for time-independent and time-dependent systems. We apply them to the description of a one dimensional atom-diatom collision. From the resulting evolution operator, we evaluate vibrational transition probabilities as well as other time-dependent properties. As expected, the ground vibrational state becomes a squeezed state during the collision.
Lankin, V Z; Ivanova, M V; Konovalova, G G; Tikhaze, A K; Kaminnyi, A I; Kukharchuk, V V
2007-04-01
We studied the effects of two inhibitors of beta-hydroxy-beta-methylglutaryl coenzyme A reductase, simvastatin and lovastatin, on the lag phase of ascorbate-dependent lipid oxidation in rat liver. Oxidizability of liver biological membranes significantly increased in intact animals and rats with induced hypercholesterolemia after peroral administration of these statins. The lag phase of ascorbate-dependent lipid oxidation in liver biomembranes decreased by 2.1 times in hypercholesterolemic rats. In animals of the lovastatin group this parameter decreased by 4.4 times compared to the control. In intact rats receiving simvastatin, the lag phase of oxidation in biomembranes from the liver decreased practically by 2 times. At the same time, in animals receiving simvastatin in combination with antioxidant vitamins (vitamins E and C, provitamin A) and selenium, the period of induction of oxidation increased by 3.3 times. Our results indicate that beta-hydroxy-beta-methylglutaryl coenzyme A reductase inhibitors produce a prooxidant effect on the liver, which can be prevented by administration of antioxidant agents.
P10.05 Establishment of team work awake craniotomy: clinical experience in Taiwan
Chen, P.; Chang, W.; Chao, Y.; Toh, C.; Wei, K.
2017-01-01
Abstract Introduction: Awake craniotomy provides the opportunity to maximize both extent of resection and preservation of neurological function. Serial preoperative and postoperative neurobehavial evaluation, magnetic resonance image examination and intraoperative task investigation need multidisciplinary experts to cooperate. Materials and Methods: From 2013, we gradually establish our team for awake craniotomy. Patient who had brain tumor with the symptom of aphasia or hemiparesis and are willing to cooperate would be entered the protocol of awake craniotomy. Patients would receive complete preoperative neurobehavial examination by psychologists and speech therapists and magnetic resonance image included diffuse tensor image. During operation, Patients went through asleep-awake-asleep anesthetic techniques. Direct electric stimulation was used for both cortical and subcortical mapping. Navigation included information of lesion and important fiber tract guided the direction of excision. Rehabilitation doctor performed the tasks and decided the positive response caused by stimulation or excisional procedure. After operation, post-operative image and neurobehavial examination would be performed within one week, 3 months, 6 months and one year later Results: We scheduled awake craniotomy on almost every Tuesday. In recent 89 patients who received awake craniotomy, Twenty-five participants with recurrent tumor underwent the operation. Seven patients received twice and one patient received three times of awake craniotomy. Two patients had controllable intraoperative seizure attack. Early termination of awake status was found in two patients due to general discomfort. Patients with modest preoperative performance status still benefit from the operation. Neurobehavioral functions improved over time and some specific feature correlate to certain aspect of quality of life. The grading of tumor and the extension of resection influence the recovery of neurobehavioral functions and progression free survival considerably. Conclusions: Awake craniotomy is a feasible and effective way to improve not only patient`s survival rate but also quality of life. A team with neurosurgeon, rehabilitation doctor, speech therapist, psychologist, anesthesiologist, nurses and other specialist is important to improve the quality of clinical care for patient who received awake craniotomy. This study is supported by Chang Gung Memorial Hospital with grant number: CMRPG3D0243
Synaptic and nonsynaptic plasticity approximating probabilistic inference
Tully, Philip J.; Hennig, Matthias H.; Lansner, Anders
2014-01-01
Learning and memory operations in neural circuits are believed to involve molecular cascades of synaptic and nonsynaptic changes that lead to a diverse repertoire of dynamical phenomena at higher levels of processing. Hebbian and homeostatic plasticity, neuromodulation, and intrinsic excitability all conspire to form and maintain memories. But it is still unclear how these seemingly redundant mechanisms could jointly orchestrate learning in a more unified system. To this end, a Hebbian learning rule for spiking neurons inspired by Bayesian statistics is proposed. In this model, synaptic weights and intrinsic currents are adapted on-line upon arrival of single spikes, which initiate a cascade of temporally interacting memory traces that locally estimate probabilities associated with relative neuronal activation levels. Trace dynamics enable synaptic learning to readily demonstrate a spike-timing dependence, stably return to a set-point over long time scales, and remain competitive despite this stability. Beyond unsupervised learning, linking the traces with an external plasticity-modulating signal enables spike-based reinforcement learning. At the postsynaptic neuron, the traces are represented by an activity-dependent ion channel that is shown to regulate the input received by a postsynaptic cell and generate intrinsic graded persistent firing levels. We show how spike-based Hebbian-Bayesian learning can be performed in a simulated inference task using integrate-and-fire (IAF) neurons that are Poisson-firing and background-driven, similar to the preferred regime of cortical neurons. Our results support the view that neurons can represent information in the form of probability distributions, and that probabilistic inference could be a functional by-product of coupled synaptic and nonsynaptic mechanisms operating over several timescales. The model provides a biophysical realization of Bayesian computation by reconciling several observed neural phenomena whose functional effects are only partially understood in concert. PMID:24782758
Simulation of ultrasonic focus aberration and correction through human tissue.
Tabei, Makoto; Mast, T Douglas; Waag, Robert C
2003-02-01
Ultrasonic focusing in two dimensions has been investigated by calculating the propagation of ultrasonic pulses through cross-sectional models of human abdominal wall and breast. Propagation calculations used a full-wave k-space method that accounts for spatial variations in density, sound speed, and frequency-dependent absorption and includes perfectly matched layer absorbing boundary conditions. To obtain a distorted receive wavefront, propagation from a point source through the tissue path was computed. Receive focusing used an angular spectrum method. Transmit focusing was accomplished by propagating a pressure wavefront from a virtual array through the tissue path. As well as uncompensated focusing, focusing that employed time-shift compensation and time-shift compensation after backpropagation was investigated in both transmit and receive and time reversal was investigated for transmit focusing in addition. The results indicate, consistent with measurements, that breast causes greater focus degradation than abdominal wall. The investigated compensation methods corrected the receive focus better than the transmit focus. Time-shift compensation after backpropagation improved the focus from that obtained using time-shift compensation alone but the improvement was less in transmit focusing than in receive focusing. Transmit focusing by time reversal resulted in lower sidelobes but larger mainlobes than the other investigated transmit focus compensation methods.
Integration of space weather into space situational awareness
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reeves, Geoffrey D
Rapid assessment of space weather effects on satellites is a critical step in anomaly resolution and satellite threat assessment. That step, however, is often hindered by a number of factors including timely collection and delivery of space weather data and the inherent com plexity of space weather information. As part of a larger, integrated space situational awareness program, Los Alamos National Laboratory has developed prototype operational space weather tools that run in real time and present operators with customized, user-specific information. The Dynamic Radiation Environment Assimilation Model (DREAM) focuses on the penetrating radiation environment from natural or nuclear-produced radiation belts.more » The penetrating radiation environment is highly dynamic and highly orbit-dependent. Operators often must rely only on line plots of 2 MeV electron flux from the NOAA geosynchronous GOES satellites which is then assumed to be representative of the environment at the satellite of interest. DREAM uses data assimilation to produce a global, real-time, energy dependent specification. User tools are built around a distributed service oriented architecture (SOA) which will allow operators to select any satellite from the space catalog and examine the environment for that specific satellite and time of interest. Depending on the application operators may need to examine instantaneous dose rates and/or dose accumulated over various lengths of time. Further, different energy thresholds can be selected depending on the shielding on the satellite or instrument of interest. In order to rapidly assess the probability that space weather was the cause of anomalous operations, the current conditions can be compared against the historical distribution of radiation levels for that orbit. In the simplest operation a user would select a satellite and time of interest and immediately see if the environmental conditions were typical, elevated, or extreme based on how often those conditions occur in that orbit. This allows users to rapidly rule in or out environmental causes of anomalies. The same user interface can also allow users to drill down for more detailed quantitative information. DREAM can be run either from a distributed web-based user interface or as a stand-alone application for secure operations. In this paper we discuss the underlying structure of the DREAM model and demonstrate the user interface that we have developed . We also present some prototype data products and user interfaces for DREAM and discuss how space environment information can be seamlessly integrated into operational SSA systems.« less
Case review analysis of operating room decisions to cancel surgery.
Chang, Ju-Hsin; Chen, Ke-Wei; Chen, Kuen-Bao; Poon, Kin-Shing; Liu, Shih-Kai
2014-07-23
Cancellation of surgery close to scheduled time causes a waste of healthcare resources. The current study analyzes surgery cancellations occurring after the patient has been prepared for the operating room, in order to see whether improvements in the surgery planning process may reduce the number of cancellations. In a retrospective chart review of operating room surgery cancellations during the period from 2006 to 2011, cancellations were divided into the following categories: inadequate NPO; medical; surgical; system; airway; incomplete evaluation. The relative use of these reasons in relation to patient age and surgical department was then evaluated. Forty-one percent of cancellations were for other than medical reasons. Among these, 17.7% were due to incomplete evaluation, and 8.2% were due to family issues. Sixty seven percent of cancelled cases eventually received surgery. The relative use of individual reasons for cancellation varied with patient age and surgical department. The difference between cancellations before and after anesthesia was dependent on the causes of cancellation, but not age, sex, ASA status, or follow-up procedures required. Almost half of the cancellations were not due to medical reasons, and these cancellations could be reduced by better administrative and surgical planning and better communication with the patient and/or his family.
Sway control method and system for rotary cranes
Robinett, R.D.; Parker, G.G.; Feddema, J.T.; Dohrmann, C.R.; Petterson, B.J.
1999-06-01
Methods and apparatuses are disclosed for reducing the oscillatory motion of rotary crane payloads during operator-commanded or computer-controlled maneuvers. An Input-shaping filter receives input signals from multiple operator input devices and converts them into output signals readable by the crane controller to dampen the payload tangential and radial sway associated with rotation of the jib. The input signals are characterized by a hub rotation trajectory [gamma](t), which includes a jib angular acceleration [gamma], a trolley acceleration x, and a load-line length velocity L. The system state variables are characterized by a tangential rotation angle [theta](t) and a radial rotation angle [phi](t) of the load-line. The coupled equations of motion governing the filter are non-linear and configuration-dependent. In one embodiment, a filter is provided between the operator and the crane for filtering undesired frequencies from the angular [gamma] and trolley x velocities to suppress payload oscillation. In another embodiment, crane commands are computer generated and controlled to suppress vibration of the payload using a postulated asymmetrical shape for the acceleration profiles of the jib, which profiles are uniquely determined by a set of parameters (including the acceleration pulse amplitude and the duration and coast time between pulses), or a dynamic programming approach. 25 figs.
Sway control method and system for rotary cranes
Robinett, Rush D.; Parker, Gordon G.; Feddema, John T.; Dohrmann, Clark R.; Petterson, Ben J.
1999-01-01
Methods and apparatuses for reducing the oscillatory motion of rotary crane payloads during operator-commanded or computer-controlled maneuvers. An Input-shaping filter receives input signals from multiple operator input devices and converts them into output signals readable by the crane controller to dampen the payload tangential and radial sway associated with rotation of the jib. The input signals are characterized by a hub rotation trajectory .gamma.(t), which includes a jib angular acceleration .gamma., a trolley acceleration x, and a load-line length velocity L. The system state variables are characterized by a tangential rotation angle .theta.(t) and a radial rotation angle .phi.(t) of the load-line. The coupled equations of motion governing the filter are non-linear and configuration-dependent. In one embodiment, a filter is provided between the operator and the crane for filtering undesired frequencies from the angular .gamma. and trolley x velocities to suppress payload oscillation. In another embodiment, crane commands are computer generated and controlled to suppress vibration of the payload using a postulated asymmetrical shape for the acceleration profiles of the jib, which profiles are uniquely determined by a set of parameters (including the acceleration pulse amplitude and the duration and coast time between pulses), or a dynamic programming approach.
Ultra-Wideband Radars for Measurements over Land and Sea Ice
NASA Astrophysics Data System (ADS)
Gogineni, S.; Hale, R.; Miller, H. G.; Yan, S.; Rodriguez-Morales, F.; Leuschen, C.; Wang, Z.; Gomez-Garcia, D.; Binder, T.; Steinhage, D.; Gehrmann, M.; Braaten, D. A.
2015-12-01
We developed two ultra-wideband (UWB) radars for measurements over the ice sheets in Greenland and Antarctica and sea ice. One of the UWB radars operates over a 150-600 MHz frequency range with a large, cross-track 24-element array. It is designed to sound ice, image the ice-bed interface, and map internal layers with fine resolution. The 24-element array consists of three 8-element sub-arrays. One of these sub-arrays is mounted under the fuselage of a BT-67 aircraft; the other two are mounted under the wings. The polarization of each antenna element can be individually reconfigured depending on the target of interest. The measured inflight VSWR is less than 2 over the operating range. The fuselage sub-array is used both for transmission and reception, and the wing-mounted sub-arrays are used for reception. The transmitter consists of an 8-channel digital waveform generator to synthesize chirped pulses of selectable pulse width, duration, and bandwidth. It also consists of drivers and power amplifiers to increase the power level of each individual channel to about 1 kW and a fast high-power transmit/receive switch. Each receiver consists of a limiter, switches, low-noise and driver amplifiers, and filters to shape and amplify received signals to the level required for digitization. The digital sub-section consists of timing and control sub-systems and 24 14-bit A/D converters to digitize received signals at a rate of 1.6 GSPS. The radar performance is evaluated using an optical delay line to simulate returns from about 2 km thick ice, and the measured radar loop sensitivity is about 215 dB. The other UWB microwave radar operates over a 2-18 GHz frequency range in Frequency-Modulated Continuous Wave (FM-CW) mode. It is designed to sound more than 1 m of snow over sea ice and map internal layers to a depth about 25-40 m in polar firn and ice. We operated the microwave radar over snow-covered sea ice and mapped snow as thin as 5 cm and as thick as 60 cm. We mapped internal layers with an early version of the radar to a depth of 45 m with fine resolution in West Antarctica. In this presentation, we will discuss design considerations and present laboratory results to document radar performance, including the impulse response functions. We will also show the results from a field campaign over the Greenland ice sheet.
Combined sewer overflow (CSO) is a significant source of pollution in receiving waters. However, implementing a real-time control scheme operates automatic regulators more efficiently to maximize a collection system's storage, treatment, and transport capacities, reducing the vol...
NASA Technical Reports Server (NTRS)
Osborne, A. E.
1973-01-01
A review of general principles and operational procedures illustrates how the typical passive user and omni receiving antenna can recover Precise Time and Time Interval (PTTI) information from a low altitude navigation satellite system for clock calibration and synchronization. Detailed discussions of concepts and theory of the receiver design are presented. The importance of RF correlation of the received and local PN encoded sequences is emphasized as a means of reducing delay uncertainties of the instrumentation to values compatible with nanosecond to submicrosecond PTTI objectives. Two receiver configurations were fabricated for use in satellite-to-laboratory experiments. In one receiver the delay-locked loop for PN signals synchronization used a dithered amplitude detection process while the second receiver used a complex sums phase detection method for measurement of delay error. The necessity for compensation of Doppler shift is discussed. Differences in theoretical signal acquisition and tracking performance of the design concepts are noted.
Gertler, Ralf; Stein, Hubert J; Langer, Rupert; Nettelmann, Marc; Schuster, Tibor; Hoefler, Heinz; Siewert, Joerg-Ruediger; Feith, Marcus
2011-04-01
We analyzed the long-term outcome of patients operated for esophageal cancer and evaluated the new seventh edition of the tumor-node-metastasis classification for cancers of the esophagus. Retrospective analysis and new classification. Data of a single-center cohort of 2920 patients operated for cancers of the esophagus according to the seventh edition are presented. Statistical methods to evaluate survival and the prognostic performance of the staging systems included Kaplan-Meier analyses and time-dependent receiver-operating-characteristic-analysis. Union Internationale Contre le Cancer stage, R-status, histologic tumor type and age were identified as independent prognostic factors for cancers of the esophagus. Grade and tumor site, additional parameters in the new American Joint Cancer Committee prognostic groupings, were not significantly correlated with survival. Esophageal adenocarcinoma showed a significantly better long-term prognosis after resection than squamous cell carcinoma (P < 0.0001). The new number-dependent N-classification proved superior to the former site-dependent classification with significantly decreasing prognosis with the increasing number of lymph node metastases (P < 0.001). The new subclassification of T1 tumors also revealed significant differences in prognosis between pT1a and pT1b patients (P < 0.001). However, the multiple new Union Internationale Contre le Cancer and American Joint Cancer Committee subgroupings did not prove distinctive for survival between stages IIA and IIB, between IIIA and IIIB, and between IIIC and IV. The new seventh edition of the tumor-node-metastasis classification improved the predictive ability for cancers of the esophagus; however, stage groups could be condensed to a clinically relevant number. Differences in patient characteristics, pathogenesis, and especially survival clearly identify adenocarcinomas and squamous cell carcinoma of the esophagus as 2 separate tumor entities requiring differentiated therapeutic concepts.
78 FR 63431 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... received no definitive data that would enable us to provide cost estimates for the on-condition actions... compliance times for certain inspections specified in this proposed AD depend on accomplishment of that... Bulletin 737-57-1318, dated May 15, 2013. For information on the procedures and compliance times, see this...
Jabbary Moghaddam, Morteza; Ommi, Davood; Mirkheshti, Alireza; Dabbagh, Ali; Memary, Elham; Sadeghi, Afsaneh; Yaseri, Mehdi
2013-01-01
Opium is a highly addictive agent and the most common narcotic often misused in Iran. The pharmacokinetic of anesthetic drugs in patients with opium addiction is one of the great challenges for anesthesiologists. Hemodynamic instability and postoperative side effects are of these challenges which should be managed correctly. In this study we aimed to assess the effects of clonidine upon post anesthesia shivering and recovery time in patients with and without opium addiction after general anesthesia to decrease the subsequent complications related to the shivering and elongation of recovery time. In a randomized clinical trial, 160 patients candidates for elective leg fracture operations under general anesthesia were studied in four groups of 40 patients: Group 1 (placebo 1) were patients without addiction who got placebo 90 minutes before the operation. Group 2 (placebo 2) were patients with opium addiction which received placebo as group 1. Group 3 (Clonidine 1) patients without addiction who got clonidine 90 minutes before the operation and group 4 (Clonidine 2) who were opium addicted ones which received clonidine as premedication. None of the patients with and without addiction in clonidine groups had shivering after the operation but in placebo groups shivering was observed and the difference between clonidine and placebo groups was statistically significant (P < 0.01). Recovery time in clonidine groups of patients with and without addiction was less than placebo ones (both P < 0.01) which the magnitude of difference was higher in opium addicted than non-addicted patients (P = 0.04). Premedication with clonidine in patients with and without opium addiction can be effective to decrease the incidence of shivering and recovery time after operation.
Jiang, Liangjun; Pan, Zhijun; Zheng, Qiang
2014-01-01
Augmentation plating has been used successfully to treat hypertrophic non-union after nail fixation. This study compared the efficacy of augmentation plating and exchange plating for treating hypertrophic non-union of femoral shaft fracture after intramedullary nail fixation. A total of 12 patients received augmentation plating and 15 patients received exchange plating as treatment for femoral shaft hypertrophic non-union. The procedures were conducted at our medical centre between January 2005 and January 2012. Clinical follow-up was conducted at 2 weeks, 1 month and then monthly until union was achieved to compare union time, operation time, bleeding and complications between the two groups. All patients underwent follow-up examinations until fracture union was achieved. The average length of follow-up time after the second treatment was (18.37 ± 3.28) months. The time needed for union was (4.17 ± 0.94) months in the augmentation plating group and (5.33 ± 1.72) months in the exchange plating group. The operation time was (90.00 ± 17.58) minutes in the augmentation plating group and (160.00 ± 25.35) minutes in the exchange plating group. The amount of blood loss during the operation was (270.00 ± 43.32) ml in the augmentation plating group and (530.00 ± 103.65) ml in the exchange plating group. Both groups showed significant difference (P < 0.05) in their results. No complications were reported after the second operation. Augmentation plating after nail fixation could remove local rotation instability, facilitate simple operation, create minimal damage and enable exercise for early functional recovery. Therefore, augmentation plating is excellent for treating hypertrophic non-union after nail fixation in femoral shaft fracture.
Comparison of two-way satellite time transfer and GPS common-view time transfer between OCA and TUG
NASA Technical Reports Server (NTRS)
Kirchner, Dieter; Thyr, U.; Ressler, H.; Robnik, R.; Grudler, P.; Baumont, Francoise S.; Veillet, Christian; Lewandowski, Wlodzimierz W.; Hanson, W.; Clements, A.
1992-01-01
For about one year the time scales UTC(OCA) and UTC(TUG) were compared by means of GPS and two-way satellite time transfer. At the end of the experiment both links were independently 'calibrated' by measuring the differential delays of the GPS receivers and of the satellite earth stations by transportation of a GPS receiver and of one of the satellite terminals. The results obtained by both methods differ by about 3 ns, but reveal a seasonal variation of about 8 ns peak-to-peak which is likely the result of a temperature-dependence of the delays of the GPS receivers used. For the comparison of both methods the stabilities of the timescales are of great importance. Unfortunately, during the last three months of the experiment a less stable clock had to be used for the generation of UTC(TUG).
Chaffee, Benjamin W; Cheng, Jing; Featherstone, John D B
2015-09-24
Consensus guidelines support non-operative preventives for dental caries management; yet, their use in practice is far from universal. The purpose of this study was to evaluate the effectiveness of non-operative anti-caries agents in caries prevention among high caries risk adults at a university clinic where risk-based caries management is emphasized. This retrospective observational study drew data from the electronic patient records of non-edentulous adult patients deemed to be at high risk for dental caries during baseline oral evaluations that were completed between July 1, 2007 and December 31, 2012 at a dental university in the United States. We calculated and compared adjusted mean estimates for the number of new decayed or restored teeth (DFT increment) from baseline to the next completed oral evaluation (N = 2,724 patients with follow-up) across three categories of delivery of non-operative anti-caries agents (e.g., high-concentration fluoride toothpaste, chlorhexidine rinse, xylitol products): never, at a single appointment, or at ≥2 appointments ≥4 weeks apart. Estimates were adjusted for patient and provider characteristics, baseline dental status, losses-to-follow-up, and follow-up time. Approximately half the patients did not receive any form of non-operative anti-caries agent. Most that received anti-caries agents were given more than one type of product in combination. One-time delivery of anti-caries agents was associated with a similar DFT increment as receiving no such therapy (difference in increment: -0.04; 95% CI: -0.28, 0.21). However, repeated, spaced delivery of anti-caries agents was associated with approximately one decayed or restored tooth prevented over 18 months for every three patients treated (difference in increment: -0.35; 95% CI: -0.65, -0.08). These results lend evidence that repeatedly receiving anti-caries agents can reduce tooth decay among high-risk patients engaged in regular dental care.
NASA Astrophysics Data System (ADS)
Engeland, K.; Steinsland, I.
2012-04-01
This work is driven by the needs of next generation short term optimization methodology for hydro power production. Stochastic optimization are about to be introduced; i.e. optimizing when available resources (water) and utility (prices) are uncertain. In this paper we focus on the available resources, i.e. water, where uncertainty mainly comes from uncertainty in future runoff. When optimizing a water system all catchments and several lead times have to be considered simultaneously. Depending on the system of hydropower reservoirs, it might be a set of headwater catchments, a system of upstream /downstream reservoirs where water used from one catchment /dam arrives in a lower catchment maybe days later, or a combination of both. The aim of this paper is therefore to construct a simultaneous probabilistic forecast for several catchments and lead times, i.e. to provide a predictive distribution for the forecasts. Stochastic optimization methods need samples/ensembles of run-off forecasts as input. Hence, it should also be possible to sample from our probabilistic forecast. A post-processing approach is taken, and an error model based on Box- Cox transformation, power transform and a temporal-spatial copula model is used. It accounts for both between catchment and between lead time dependencies. In operational use it is strait forward to sample run-off ensembles from this models that inherits the catchment and lead time dependencies. The methodology is tested and demonstrated in the Ulla-Førre river system, and simultaneous probabilistic forecasts for five catchments and ten lead times are constructed. The methodology has enough flexibility to model operationally important features in this case study such as hetroscadasety, lead-time varying temporal dependency and lead-time varying inter-catchment dependency. Our model is evaluated using CRPS for marginal predictive distributions and energy score for joint predictive distribution. It is tested against deterministic run-off forecast, climatology forecast and a persistent forecast, and is found to be the better probabilistic forecast for lead time grater then two. From an operational point of view the results are interesting as the between catchment dependency gets stronger with longer lead-times.
ngVLA Cryogenic Subsystem Concept
NASA Astrophysics Data System (ADS)
Wootten, Al; Urbain, Denis; Grammer, Wes; Durand, S.
2018-01-01
The VLA’s success over 35 years of operations stems in part from dramatically upgraded components over the years. The time has come to build a new array to lead the radio astronomical science into its next 40 years. To accomplish that, a next generation VLA (ngVLA) is envisioned to have 214 antennas with diameters of 18m. The core of the array will be centered at the current VLA location, but the arms will extend out to 1000km.The VLA cryogenic subsystem equipment and technology have remained virtually unchanged since the early 1980s. While adequate for a 27-antenna array, scaling the current system for an array of 214 antennas would be prohibitively expensive in terms of operating cost and maintenance. The overall goal is to limit operating cost to within three times the current level, despite having 8 times the number of antennas. To help realize this goal, broadband receivers and compact feeds will be utilized to reduce both the size and number of cryostats required. The current baseline front end concept calls for just two moderately-sized cryostats for the entire 1.2-116 GHz frequency range, as opposed to 8 in the VLA.For the ngVLA cryogenics, our objective is a well-optimized and efficient system that uses state-of-the-art technology to minimize per-antenna power consumption and maximize reliability. Application of modern technologies, such as variable-speed operation for the scroll compressors and cryocooler motor drives, allow the cooling capacity of the system to be dynamically matched to thermal loading in each cryostat. Significantly, power savings may be realized while the maintenance interval of the cryocoolers is also extended.Finally, a receiver designed to minimize thermal loading can produce savings directly translating to lower operating cost when variable-speed drives are used. Multi-layer insulation (MLI) on radiation shields and improved IR filters on feed windows can significantly reduce heat loading.Measurements done on existing cryogenic equipment show that the proposed baseline receiver concept with two cryostats, combined with variable-speed operation of the compressor and cryocoolers should allow the operating cost for ngVLA cryogenics to remain within a factor of two over the VLA.
Stability and Phase Noise Tests of Two Cryo-Cooled Sapphire Oscillators
NASA Technical Reports Server (NTRS)
Dick, G. John; Wang, Rabi T.
1998-01-01
A cryocooled Compensated Sapphire Oscillator (CSO), developed for the Cassini Ka-band Radio Science experiment, and operating in the 8K - 10K temperature range was previously demonstrated to show ultra-high stability of sigma(sub y) = 2.5 x 10 (exp -15) for measuring times 200 seconds less than or equal to tau less than or equal to 600 seconds using a hydrogen maser as reference. We present here test results for a second unit which allows CSO short-term stability and phase noise to be measured for the first time. Also included are design details of a new RF receiver and an intercomparison with the first CSO unit. Cryogenic oscillators operating below about 10K offer the highest possible short term stability of any frequency sources. However, their use has so far been restricted to research environments due to the limited operating periods associated with liquid helium consumption. The cryocooled CSO is being built in support of the Cassini Ka-band Radio Science experiment and is designed to operate continuously for periods of a year or more. Performance targets are a stability of 3-4 x 10 (exp -15) (1 second less than or equal to tau less than or equal to 100 seconds) and phase noise of -73dB/Hz @ 1Hz measured at 34 GHz. Installation in 5 stations of NASA's deep space network (DSN) is planned in the years 2000 - 2002. In the previous tests, actual stability of the CSO for measuring times tau less than or equal to 200 seconds could not be directly measured, being masked by short-term fluctuations of the H-maser reference. Excellent short-term performance, however, could be inferred by the success of an application of the CSO as local oscillator (L.O.) to the JPL LITS passive atomic standard, where medium-term stability showed no degradation due to L.O. instabilities at a level of (sigma)y = 3 x 10 (exp -14)/square root of tau. A second CSO has now been constructed, and all cryogenic aspects have been verified, including a resonator turn-over temperature of 7.907 K, and Q of 7.4 x 10 (exp 8). These values compare to a turn-over of 8.821 K and Q of 1.0 x 10 (exp 9) for the first resonator. Operation of this second unit provides a capability to directly verify for the first time the short-term (1 second less than or equal to tau less than or equal to 200 seconds) stability and the phase noise of the CSO units. The RF receiver used in earlier tests was sufficient to meet Cassini requirements for tau greater than or equal to 10 seconds but had short-term stability limited to 2-4 x 10 (exp -14) at tau = 1 second, a value 10 times too high to meet our requirements. A new low-noise receiver has been designed to provide approximately equal to 10-15 performance at 1 second, and one receiver is now operational, demonstrating again short-term CSO performance with H maser-limited stability. Short-term performance was degraded in the old receiver due to insufficient tuning bandwidth in a 100MHZ quartz VCO that was frequency-locked to the cryogenic sapphire resonator. The new receivers are designed for sufficient bandwidth, loop gain and low noise to achieve the required performance.
Real-time volcano monitoring using GNSS single-frequency receivers
NASA Astrophysics Data System (ADS)
Lee, Seung-Woo; Yun, Sung-Hyo; Kim, Do Hyeong; Lee, Dukkee; Lee, Young J.; Schutz, Bob E.
2015-12-01
We present a real-time volcano monitoring strategy that uses the Global Navigation Satellite System (GNSS), and we examine the performance of the strategy by processing simulated and real data and comparing the results with published solutions. The cost of implementing the strategy is reduced greatly by using single-frequency GNSS receivers except for one dual-frequency receiver that serves as a base receiver. Positions of the single-frequency receivers are computed relative to the base receiver on an epoch-by-epoch basis using the high-rate double-difference (DD) GNSS technique, while the position of the base station is fixed to the values obtained with a deferred-time precise point positioning technique and updated on a regular basis. Since the performance of the single-frequency high-rate DD technique depends on the conditions of the ionosphere over the monitoring area, the ionospheric total electron content is monitored using the dual-frequency data from the base receiver. The surface deformation obtained with the high-rate DD technique is eventually processed by a real-time inversion filter based on the Mogi point source model. The performance of the real-time volcano monitoring strategy is assessed through a set of tests and case studies, in which the data recorded during the 2007 eruption of Kilauea and the 2005 eruption of Augustine are processed in a simulated real-time mode. The case studies show that the displacement time series obtained with the strategy seem to agree with those obtained with deferred-time, dual-frequency approaches at the level of 10-15 mm. Differences in the estimated volume change of the Mogi source between the real-time inversion filter and previously reported works were in the range of 11 to 13% of the maximum volume changes of the cases examined.
Chong, C; Wang, T; Chen, C; Ma, H; Chang, H
2004-01-01
Objective: 279 cases of appendicitis were reviewed and compared for the difference between those patients who received pain medication before consulting a surgeon and those who were not treated with analgesics. Methods: All patients aged 15 years and older who underwent appendicectomy for appendicitis between 1 July 2001 and 30 June 2002 were divided into group 1 (those who received preconsultaion use of analgesics) and group 2 (those who were not treated with analgesics). The following measures were compared: age, sex, symptom duration, initial vital signs, white blood cell counts, frequency of imaging studies, time to operative intervention, and operative findings. Continuous and categorical variables were analysed using t and χ2 tests, respectively. Results: A total of 279 patients were included for analysis. Patient details (age, sex, symptom duration) of the two study groups were similar. There was no statistically significant difference between group 1 and group 2 with respect to vital signs (systolic blood pressure, pulse rate, respiratory rate, body temperature), white blood cell counts, and frequency of imaging studies (ultrasound, computed tomography). There was no significant difference in the rate of perforated appendicitis between the two study groups although a shorter median time to operative intervention has been found in the group who received analegesia. Conclusion: The preconsultation use of analgesics in ED patients with a final diagnosis of appendicitis is not associated with a longer delay to operative intervention and is not associated with an increased rate of perforated appendicitis. PMID:14734373
Noncommuting observables in quantum detection and estimation theory
NASA Technical Reports Server (NTRS)
Helstrom, C. W.
1972-01-01
Basing decisions and estimates on simultaneous approximate measurements of noncommuting observables in a quantum receiver is shown to be equivalent to measuring commuting projection operators on a larger Hilbert space than that of the receiver itself. The quantum-mechanical Cramer-Rao inequalities derived from right logarithmic derivatives and symmetrized logarithmic derivatives of the density operator are compared, and it is shown that the latter give superior lower bounds on the error variances of individual unbiased estimates of arrival time and carrier frequency of a coherent signal. For a suitably weighted sum of the error variances of simultaneous estimates of these, the former yield the superior lower bound under some conditions.
Kuroda, Daisuke; Sawayama, Hiroshi; Kurashige, Junji; Iwatsuki, Masaaki; Eto, Tsugio; Tokunaga, Ryuma; Kitano, Yuki; Yamamura, Kensuke; Ouchi, Mayuko; Nakamura, Kenichi; Baba, Yoshifumi; Sakamoto, Yasuo; Yamashita, Yoichi; Yoshida, Naoya; Chikamoto, Akira; Baba, Hideo
2018-03-01
Controlling Nutritional Status (CONUT), as calculated from serum albumin, total cholesterol concentration, and total lymphocyte count, was previously shown to be useful for nutritional assessment. The current study investigated the potential use of CONUT as a prognostic marker in gastric cancer patients after curative resection. Preoperative CONUT was retrospectively calculated in 416 gastric cancer patients who underwent curative resection at Kumamoto University Hospital from 2005 to 2014. The patients were divided into two groups: CONUT-high (≥4) and CONUT-low (≤3), according to time-dependent receiver operating characteristic (ROC) analysis. The associations of CONUT with clinicopathological factors and survival were evaluated. CONUT-high patients were significantly older (p < 0.001) and had a lower body mass index (p = 0.019), deeper invasion (p < 0.001), higher serum carcinoembryonic antigen (p = 0.037), and higher serum carbohydrate antigen 19-9 (p = 0.007) compared with CONUT-low patients. CONUT-high patients had significantly poorer overall survival (OS) compared with CONUT-low patients according to univariate and multivariate analyses (hazard ratio: 5.09, 95% confidence interval 3.12-8.30, p < 0.001). In time-dependent ROC analysis, CONUT had a higher area under the ROC curve (AUC) for the prediction of 5-year OS than the neutrophil lymphocyte ratio, the Modified Glasgow Prognostic Score, or pStage. When the time-dependent AUC curve was used to predict OS, CONUT tended to maintain its predictive accuracy for long-term survival at a significantly higher level for an extended period after surgery when compared with the other markers tested. CONUT is useful for not only estimating nutritional status but also for predicting long-term OS in gastric cancer patients after curative resection.
NASA Technical Reports Server (NTRS)
Gomez, Susan F.; Lammers, Michael L.
2004-01-01
The Global Positioning System Subsystem (GPS) for International Space Station (ISS) was activated April 12,2002 following the installation of the SO truss segment that included the GPS antennas on Shuttle mission STS-110. The ISS GPS receiver became the primary source for position, velocity, and attitude information for ISS two days after activation. The GPS receiver also provides a time reference for manual control of ISS time, and will be used for automatic time updates after problems are resolved with the output from the receiver. After two years of on-orbit experience, the GPS continues to be used as the primary navigation source for ISS; however, enough problems have surfaced that the firmware in the GPS attitude code has had to be totally rewritten and new algorithms developed, the firmware that processed the time output from the GPS receiver had to be rewritten, while the GPS navigation code has had minor revisions. The factors contributing to the delivery of a GPS receiver for use on ISS that requires extensive operator intervention to function are discussed. Observations from two years worth of GPS solutions will also be discussed. The technical solutions to the anomalous GPS receiver behavior will be discussed.
Spectrum of Quantized Energy for a Lengthening Pendulum
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jeong Ryeol; Song, Ji Nny; Hong, Seong Ju
We considered a quantum system of simple pendulum whose length of string is increasing at a steady rate. Since the string length is represented as a time function, this system is described by a time-dependent Hamiltonian. The invariant operator method is very useful in solving the quantum solutions of time-dependent Hamiltonian systems like this. The invariant operator of the system is represented in terms of the lowering operator a(t) and the raising operator a{sup {dagger}}(t). The Schroedinger solutions {psi}{sub n}({theta}, t) whose spectrum is discrete are obtained by means of the invariant operator. The expectation value of the Hamiltonian inmore » the {psi}{sub n}({theta}, t) state is the same as the quantum energy. At first, we considered only {theta}{sup 2} term in the Hamiltonian in order to evaluate the quantized energy. The numerical study for quantum energy correction is also made by considering the angle variable not only up to {theta}{sup 4} term but also up to {theta}{sup 6} term in the Hamiltonian, using the perturbation theory.« less
Ma, Zhi-Guo; Guo, Yong-Jun; Yan, Hou-Jun; Li, Qi-Ming; Ma, Bin
2017-02-01
The function of the donor foot has been affected after using big toe wrap-around flap for thumb reconstruction. A modified operation method has been developed to reduce the adverse effect on the donor foot. The current study compared the long-term effect of the classic and the modified operation methods on the donor foot. Gait analysis was carried out, including how the patient walked, the walking speed and walking distance, and how the patient jumped and ran. Plantar pressure was measured while the patient was standing and moving. A total of 45 patients who received the 2 different operation methods were included. The follow-up time was 4-10 years with a mean of 6.5 years. Various degrees of complications occurred for the 21 patients who received the classic operation method. For these patients, plantar pressure of the donor foot was obviously different comparing with the healthy unaffected foot while the patient was standing or walking. For the 24 patients who received the modified operation method, no obvious complications were observed and the plantar pressure of the donor foot and the healthy unaffected foot was similar while the patient was standing or walking. In conclusion, both the classic and the modified operation methods have affected the function of the donor foot after using the big toe wrap-around flap for thumb reconstruction. However, the donor foot was less affected when the modified operation method was used.
NASA Astrophysics Data System (ADS)
Bogachev, V. A.; Pshechenkova, T. P.; Shumovskaya, M. A.
2016-04-01
The elemental composition of an altered layer at the external surface of a steam superheating tube of grade DI59 steel is investigated after long-term operation. It is shown that the layer is located between a scale and a matrix and depleted by silicon, manganese, copper, and chromium with the maximum oxidizer affinity, enriched by iron and nickel to 90%, and mainly composed of the α-Fe phase (ferrite) with the ferromagnetic properties. The layer formed as a result of selective oxidation and diffusion from the matrix into the metal scale with the less standard free energy of the formation of sulfides and oxides. A magnetic ferrite meter is used in the experimental investigation of the layer evolution by testing grade DI59 steel for heat resistance in air environment at temperatures of 585, 650, and 700°C for 15 × 103 h; creep at a temperature of 750°C and a stress of 60 MPa; and long-term strength at temperatures of 700 and 750°C and stresses of from 30 to 80 MPa. Specimens for tests are made of tubes under as-received conditions. The relationship between the ferrite phase content in the surface metal layer and the temperature and time of test is determined. The dependence is developed to evaluate the equivalent temperature for operation of the external surface of steam superheating tubes using data of magnetic ferritometry. It is shown that operation temperatures that are determined by the ferrite phase content and the σ phase concentration in the metal structure of steam superheating tubes with the significant operating time are close. It is proposed to use magnetic ferritometry for revelation of thermal nonuniformity and worst tubes of steam superheaters of HPP boilers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wendelin, Timothy J; Ho, Clifford K.; Horstman, Luke
This paper presents a study of alternative heliostat standby aiming strategies and their impact on avian flux hazards and operational performance of a concentrating solar power plant. A mathematical model was developed that predicts the bird-feather temperature as a function of solar irradiance, thermal emittance, convection, and thermal properties of the feather. The irradiance distribution in the airspace above the Ivanpah Unit 2 heliostat field was simulated using a ray-trace model for two different times of the day, four days of the year, and nine different standby aiming strategies. The impact of the alternative aiming strategies on operational performance wasmore » assessed by comparing the heliostat slew times from standby position to the receiver for the different aiming strategies. Increased slew times increased a proxy start-up time that reduced the simulated annual energy production. Results showed that spreading the radial aim points around the receiver to a distance of ~150 m or greater reduced the hazardous exposure times that the feather temperature exceeded the hazard metric of 160 degrees C. The hazardous exposure times were reduced by ~23% and 90% at a radial spread of aim points extending to 150 m and 250 m, respectively, but the simulated annual energy production decreased as a result of increased slew times. Single point-focus aiming strategies were also evaluated, but these strategies increased the exposure hazard relative to other aiming strategies.« less
1972-01-01
and police stations in Washington, and since 1877 to Western Union for nation-wide distribution. In 1904 the first operational radio time signals were...to do the job with the accuracy and low cost demanded in these days of tight operating budgets. In closing, I would like to acknowledge the fine...signal received from a celestial source is recorded at each antenna on magnetic tape, and the tapes are cross-correlated by matching the streams of
NASA Astrophysics Data System (ADS)
Li, Jiqing; Huang, Jing; Li, Jianchang
2018-06-01
The time-varying design flood can make full use of the measured data, which can provide the reservoir with the basis of both flood control and operation scheduling. This paper adopts peak over threshold method for flood sampling in unit periods and Poisson process with time-dependent parameters model for simulation of reservoirs time-varying design flood. Considering the relationship between the model parameters and hypothesis, this paper presents the over-threshold intensity, the fitting degree of Poisson distribution and the design flood parameters are the time-varying design flood unit period and threshold discriminant basis, deduced Longyangxia reservoir time-varying design flood process at 9 kinds of design frequencies. The time-varying design flood of inflow is closer to the reservoir actual inflow conditions, which can be used to adjust the operating water level in flood season and make plans for resource utilization of flood in the basin.
Non-intrusive measurement of hot gas temperature in a gas turbine engine
DeSilva, Upul P.; Claussen, Heiko; Yan, Michelle Xiaohong; Rosca, Justinian; Ulerich, Nancy H.
2016-09-27
A method and apparatus for operating a gas turbine engine including determining a temperature of a working gas at a predetermined axial location within the engine. An acoustic signal is encoded with a distinct signature defined by a set of predetermined frequencies transmitted as a non-broadband signal. Acoustic signals are transmitted from an acoustic transmitter located at a predetermined axial location along the flow path of the gas turbine engine. A received signal is compared to one or more transmitted signals to identify a similarity of the received signal to a transmitted signal to identify a transmission time for the received signal. A time-of-flight is determined for the signal and the time-of-flight for the signal is processed to determine a temperature in a region of the predetermined axial location.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., and consignees may be known prior to exportation. The procedures for obtaining certification as an AES... authorized agent shall file the required EEI and have received the AES ITN no later than the time period... because the AES is not operating, the filer shall not export until the AES is operating and an ITN is...
Code of Federal Regulations, 2010 CFR
2010-01-01
..., and consignees may be known prior to exportation. The procedures for obtaining certification as an AES... authorized agent shall file the required EEI and have received the AES ITN no later than the time period... because the AES is not operating, the filer shall not export until the AES is operating and an ITN is...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., and consignees may be known prior to exportation. The procedures for obtaining certification as an AES... authorized agent shall file the required EEI and have received the AES ITN no later than the time period... because the AES is not operating, the filer shall not export until the AES is operating and an ITN is...
Code of Federal Regulations, 2011 CFR
2011-01-01
..., and consignees may be known prior to exportation. The procedures for obtaining certification as an AES... authorized agent shall file the required EEI and have received the AES ITN no later than the time period... because the AES is not operating, the filer shall not export until the AES is operating and an ITN is...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., and consignees may be known prior to exportation. The procedures for obtaining certification as an AES... authorized agent shall file the required EEI and have received the AES ITN no later than the time period... because the AES is not operating, the filer shall not export until the AES is operating and an ITN is...
Limitations of discrete-time quantum walk on a one-dimensional infinite chain
NASA Astrophysics Data System (ADS)
Lin, Jia-Yi; Zhu, Xuanmin; Wu, Shengjun
2018-04-01
How well can we manipulate the state of a particle via a discrete-time quantum walk? We show that the discrete-time quantum walk on a one-dimensional infinite chain with coin operators that are independent of the position can only realize product operators of the form eiξ A ⊗1p, which cannot change the position state of the walker. We present a scheme to construct all possible realizations of all the product operators of the form eiξ A ⊗1p. When the coin operators are dependent on the position, we show that the translation operators on the position can not be realized via a DTQW with coin operators that are either the identity operator 1 or the Pauli operator σx.
Functional differentiability in time-dependent quantum mechanics.
Penz, Markus; Ruggenthaler, Michael
2015-03-28
In this work, we investigate the functional differentiability of the time-dependent many-body wave function and of derived quantities with respect to time-dependent potentials. For properly chosen Banach spaces of potentials and wave functions, Fréchet differentiability is proven. From this follows an estimate for the difference of two solutions to the time-dependent Schrödinger equation that evolve under the influence of different potentials. Such results can be applied directly to the one-particle density and to bounded operators, and present a rigorous formulation of non-equilibrium linear-response theory where the usual Lehmann representation of the linear-response kernel is not valid. Further, the Fréchet differentiability of the wave function provides a new route towards proving basic properties of time-dependent density-functional theory.
Coin state properties in quantum walks
Andrade, R. F. S.
2013-01-01
Recent experimental advances have measured individual coin components in discrete time quantum walks, which have not received the due attention in most theoretical studies on the theme. Here is presented a detailed investigation of the properties of M, the difference between square modulus of coin states of discrete quantum walks on a linear chain. Local expectation values are obtained in terms of real and imaginary parts of the Fourier transformed wave function. A simple expression is found for the average difference between coin states in terms of an angle θ gauging the coin operator and its initial state. These results are corroborated by numerical integration of dynamical equations in real space. The local dependence is characterized both by large and short period modulations. The richness of revealed patterns suggests that the amount of information stored and retrieved from quantum walks is significantly enhanced if M is taken into account. PMID:23756358
Operational features of decorative concrete
NASA Astrophysics Data System (ADS)
Bazhenova, Olga; Kotelnikov, Maxim
2018-03-01
This article deals with the questions of creation and use of decorative and finishing concrete and mortar. It has been revealed that the most effective artificial rock-imitating stone materials are those made of decorative concrete with the opened internal structure of material. At the same time it is important that the particles of decorative aggregate should be distributed evenly in the concrete volume. It can be reached only at a continuous grain-size analysis of the aggregate from the given rock. The article tackles the necessity of natural stone materials imitation for the cement stone color to correspond to the color of the rock. The possibility of creation of the decorative concrete imitating rocks in the high-speed turbulent mixer is considered. Dependences of durability and frost resistance of the studied concrete on the pore size and character and also parameters characterizing crack resistance of concrete are received.
Justifying scale type for a latent variable: Formative or reflective?
NASA Astrophysics Data System (ADS)
Liu, Hao; Bahron, Arsiah; Bagul, Awangku Hassanal Bahar Pengiran
2015-12-01
The study attempted to explore the possibilities to create a procedure at the experimental level to double confirm whether manifest variables scale type is formative or reflective. Now, the criteria of making such a decision are heavily depended on researchers' judgment at the conceptual and operational level. The study created an experimental procedure that seems could double confirm the decisions from the conceptual and operational level judgments. The experimental procedure includes the following tests, Variance Inflation Factor (VIF), Tolerance (TOL), Ridge Regression, Cronbach's alpha, Dillon-Goldstein's rho, and first and second eigenvalue. The procedure considers manifest variables' both multicollinearity and consistency. As the result, the procedure received the same judgment with the carefully established decision making at the concept and operational level.
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Sun, Xiaoli; Field, Christopher T.
1995-01-01
Laser altimeters measure the time of flight of the laser pulses to determine the range of the target. The simplest altimeter receiver consists of a photodetector followed by a leading edge detector. A time interval unit (TIU) measures the time from the transmitted laser pulse to the leading edge of the received pulse as it crosses a preset threshold. However, the ranging error of this simple detection scheme depends on the received, pulse amplitude, pulse shape, and the threshold. In practice, the pulse shape and the amplitude are determined by the target target characteristics which has to be assumed unknown prior to the measurement. The ranging error can be improved if one also measures the pulse width and use the average of the leading and trailing edges (half pulse width) as the pulse arrival time. The ranging error becomes independent of the received pulse amplitude and the pulse width as long as the pulse shape is symmetric. The pulse width also gives the slope of the target. The ultimate detection scheme is to digitize the received waveform and calculate the centroid as the pulse arrival time. The centroid detection always gives unbiased measurement even for asymmetric pulses. In this report, we analyze the laser altimeter ranging errors for these three detection schemes using the Mars Orbital Laser Altimeter (MOLA) as an example.
2013-01-01
Background Subarachnoid hemorrhage is a common and dangerous disease with an unfavorable prognosis. Patients with poor-grade subarachnoid hemorrhage (Hunt & Hess Grades 4–5) are unconscious on admission. Because of the high mortality and disability rate associated with poor-grade subarachnoid hemorrhage, it is often treated conservatively. Timing of surgery for poor-grade aneurysmal subarachnoid hemorrhage is still controversial, therefore this study aims to identify the optimal time to operate on patients admitted in poor clinical condition. Methods/design Ninety-nine patients meeting the inclusion criteria were randomly assigned into three treatment groups. The early surgery group received operation within 3 days after onset of subarachnoid hemorrhage (day of SAH = day 1); the intermediate surgery group received operation from days 4 to 7, and surgery was performed on the late surgery group after day 7. Follow-up was performed 1, 3, and 6 months after aneurysm clipping. Primary indicators of outcome included the Extended Glasgow Outcome Scale and the Modified Rankin Scale, while secondary indicators of outcome were assessed using the Barthel Index and mortality. Discussion This is the first prospective, single-center, observer-blinded, randomized controlled trial to elucidate optimal timing for surgery in poor-grade subarachnoid hemorrhage patients. The results of this study will be used to direct decisions of surgical intervention in poor-grade subarachnoid hemorrhage, thus improving clinical outcomes for patients. Trial registration Chinese Clinical Trial Registry: ChiCTR-TRC-12002917 PMID:23957458
Development of a Software-Defined Radar
2017-10-01
waveform to the widest available (unoccupied) instantaneous bandwidth in real time. Consequently, the radar range resolution and target detection are...LabVIEW The matched filter range profile is calculated in real time using fast Fourier transform (FFT) operations to perform a cross-correlation...between the transmitted waveform and the received complex data. Figure 4 demonstrates the block logic used to achieve real -time range profile
Chaining direct memory access data transfer operations for compute nodes in a parallel computer
Archer, Charles J.; Blocksome, Michael A.
2010-09-28
Methods, systems, and products are disclosed for chaining DMA data transfer operations for compute nodes in a parallel computer that include: receiving, by an origin DMA engine on an origin node in an origin injection FIFO buffer for the origin DMA engine, a RGET data descriptor specifying a DMA transfer operation data descriptor on the origin node and a second RGET data descriptor on the origin node, the second RGET data descriptor specifying a target RGET data descriptor on the target node, the target RGET data descriptor specifying an additional DMA transfer operation data descriptor on the origin node; creating, by the origin DMA engine, an RGET packet in dependence upon the RGET data descriptor, the RGET packet containing the DMA transfer operation data descriptor and the second RGET data descriptor; and transferring, by the origin DMA engine to a target DMA engine on the target node, the RGET packet.
Achleitner, S; De Toffol, S; Engelhard, C; Rauch, W
2005-01-01
In river stretches being subjected to flow regulation, usually for the purpose of energy production (e.g. Hydropower) or flood protection (river barrage), a special measure can be taken against the effect of combined sewer overflows (CSOs). The basic idea is the temporal increase of the river base flow (during storm weather) as an in-stream measure for mitigation of CSO spilling. The focus is the mitigation of the negative effect of acute pollution of substances. The measure developed can be seen as an application of the classic real time control (RTC) concept onto the river system. Upstream gate operation is to be based on real time monitoring and forecasting of precipitation. The main objective is the development of a model based predictive control system for the gate operation, by modelling of the overall wastewater system (incl. the receiving water). The main emphasis is put on the operational strategy and the appropriate short-term forecast of spilling events. The potential of the measure is tested for the application of the operational strategy and its ecological and economic feasibility. The implementation of such an in-stream measure into the hydropower's operational scheme is unique. Advantages are (a) the additional in-stream dilution of acute pollutants entering the receiving water and (b) the resulting minimization of the required CSO storage volume.
More for less: best patient outcomes in a time of financial restraint.
Merry, Alan F; Hamblin, Richard
2012-12-01
In many countries, expenditure on health care has increased dramatically over recent years. There have been parallel improvements in many indicators of population health, but too many patients continue to be harmed by health care or receive care that is supply-sensitive, ineffective, or poorly aligned with their needs and values. In addition to human costs, this translates into substantial waste of resource. The world has recently faced economic challenges unseen since the great depression of the 1930s. The financial situation of a country can, like a business, be expressed in three sets of accounts: statements of financial position, financial performance, and cash flow. A key test of solvency is the ability to pay debts as they become due (whether from current account or further borrowing). In general, this is a function of public debt, which for many countries has become very high. However, private debt and net financial position are also relevant to a country's financial prospects. Ultimately, borrowing is not sustainable indefinitely and given limited prospects for growth in income in the coming years, most countries will likely need to reduce or at least constrain expenditure on health care. This implies obtaining better value from the resources that are available, and we suggest that the key to this lies in improving the quality of care and, in particular, reducing variation in health care. In the United States, new legislation promoting accountable care organizations may help to do this. Cardiac surgery can be particularly effective in extending patients' lives and in improving the quality of their lives. Our ability to continue to provide cardiac surgery in the face of constrained economic times will depend on engaging more actively in ensuring that what we do is the right thing: that our operations are effective and that they truly meet the needs and values of our patients. It will also depend on doing these operations right the first time.
More for Less: Best Patient Outcomes in a Time of Financial Restraint
Merry, Alan F.; Hamblin, Richard
2012-01-01
Abstract: In many countries, expenditure on health care has increased dramatically over recent years. There have been parallel improvements in many indicators of population health, but too many patients continue to be harmed by health care or receive care that is supply-sensitive, ineffective, or poorly aligned with their needs and values. In addition to human costs, this translates into substantial waste of resource. The world has recently faced economic challenges unseen since the great depression of the 1930s. The financial situation of a country can, like a business, be expressed in three sets of accounts: statements of financial position, financial performance, and cash flow. A key test of solvency is the ability to pay debts as they become due (whether from current account or further borrowing). In general, this is a function of public debt, which for many countries has become very high. However, private debt and net financial position are also relevant to a country’s financial prospects. Ultimately, borrowing is not sustainable indefinitely and given limited prospects for growth in income in the coming years, most countries will likely need to reduce or at least constrain expenditure on health care. This implies obtaining better value from the resources that are available, and we suggest that the key to this lies in improving the quality of care and, in particular, reducing variation in health care. In the United States, new legislation promoting accountable care organizations may help to do this. Cardiac surgery can be particularly effective in extending patients’ lives and in improving the quality of their lives. Our ability to continue to provide cardiac surgery in the face of constrained economic times will depend on engaging more actively in ensuring that what we do is the right thing: that our operations are effective and that they truly meet the needs and values of our patients. It will also depend on doing these operations right the first time. PMID:23441557
Determining a bisection bandwidth for a multi-node data communications network
Faraj, Ahmad A.
2010-01-26
Methods, systems, and products are disclosed for determining a bisection bandwidth for a multi-node data communications network that include: partitioning nodes in the network into a first sub-network and a second sub-network in dependence upon a topology of the network; sending, by each node in the first sub-network to a destination node in the second sub-network, a first message having a predetermined message size; receiving, by each node in the first sub-network from a source node in the second sub-network, a second message; measuring, by each node in the first sub-network, the elapsed communications time between the sending of the first message and the receiving of the second message; selecting the longest elapsed communications time; and calculating the bisection bandwidth for the network in dependence upon the number of the nodes in the first sub-network, the predetermined message size of the first test message, and the longest elapsed communications time.
NASA Astrophysics Data System (ADS)
Gladshteyn, V. I.; Troitskiy, A. I.
2017-01-01
Research of a metal of the stop valve case (SVC) of the K-300-23.5 LMZ turbine (steel grade 15Kh1M1FL), destroyed after operation for 331000 hours, is performed. It's chemical composition and properties are determined as follows: a short-term mechanical tensile stress at 20°C and at elevated temperature, critical temperature, fragility, critical crack opening at elevated temperature, and long-term strength. Furthermore, nature of the microstructure, packing density of carbide particles and their size, and chemical composition of carbide sediment are estimated. A manifestation of metal properties for the main case components by comparison with a forecast of the respective characteristics made for the operating time of 331000 hours is tested. Property-time relationships are built for the forecast using statistical treatment of the test results for the samples cut out from more than 300 parts. Representativeness of the research results is proved: the statistical treatment of their differences are within the range of ±5%. It has been found that, after 150000 hours of operation, only the tensile strength insignificantly depends on the operating time at 20°C, whereas indicators of strength at elevated temperature significantly reduce, depending on the operating time. A brittle-to-ductile transition temperature (BDTT) raises, a critical notch opening changes in a complicated way, a long-term strength reduces. It has been found empirically that the limit of a long-term strength of the SVC metal at 540°C and the operating time of 105 hours is almost 1.6 times less than the required value in the as-delivered state. It is possible to evaluate a service life of the operating valves with the operating time of more than 330000 hours with respect to the long-term strength of the metal taking into account the actual temperature and stress. Guidelines for the control of similar parts are provided.
Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng
2015-12-01
Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P < 0.001). The fluoroscopic times were 14.03 ± 2.54 in Group A and 25.19 ± 4.28 in Group B (P < 0.001). The preoperative location time was 4.67 ± 1.41 minutes in Group A and 6.98 ± 0.94 minutes in Group B (P < 0.001). The operation time was 79.42 ± 10.15 minutes in Group A and 89.65 ± 14.06 minutes in Group B (P = 0.002). The hospital stay was 2.77 ± 0.95 days in Group A and 2.87 ± 1.02 days in Group B (P = 0.702). There were no significant differences in the complication rate between the 2 groups (P = 0.386).The highlight of HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).
Spaceborne receivers: Basic principles
NASA Technical Reports Server (NTRS)
Stacey, J. M.
1984-01-01
The underlying principles of operation of microwave receivers for space observations of planetary surfaces were examined. The design philosophy of the receiver as it is applied to operate functionally as an efficient receiving system, the principle of operation of the key components of the receiver, and the important differences among receiver types are explained. The operating performance and the sensitivity expectations for both the modulated and total power receiver configurations are outlined. The expressions are derived from first principles and are developed through the important intermediate stages to form practicle and easily applied equations. The transfer of thermodynamic energy from point to point within the receiver is illustrated. The language of microwave receivers is applied statistics.
von Rüden, Christian; Morgenstern, Mario; Friederichs, Jan; Augat, Peter; Hackl, Simon; Woltmann, Alexander; Bühren, Volker; Hierholzer, Christian
2016-11-01
The purpose of this study was to evaluate the clinical and radiological outcome following compression plate fixation in combination with autologous bone grafting, with and without additional application of recombinant human bone morphogenetic protein (rhBMP) for treatment of aseptic clavicle non-union. Between April 2004 and April 2015, 82 patients were treated for clavicle fracture and had developed aseptic clavicle non-union. Seventy-three out of 82 patients were available for follow-up at least one year after revision surgery; among them, 27 women and 46 men, with a median age of 49 (range, 19-86) years. Forty-five patients received compression plate osteosynthesis with autologous bone grafting, and 28 patients obtained compression plate fixation with autologous bone grafting and additional application of rhBMP-2 (3/28 patients) or rhBMP-7 (25/28 patients). Seventy out of 73 non-unions (96 %) healed within 12 months after revision surgery. Functional outcome according to the DASH Outcome Measure (with rhBMP, 33.16 ± 1.17 points; without rhBMP, 30.58 ± 2.12 points [mean ± SEM]; p = 0.81), non-union healing (p = 0.86), time interval between revision surgery and bone healing (p = 0.37), as well as post-operative complications, did not demonstrate relevant differences between the treatment groups and were not age-dependent. Functional and radiological results demonstrate that successful healing of aseptic clavicle non-union is dependent on radical resection of non-union tissue, restoration of length of the shoulder girdle and application of stable locking-plate osteosynthesis in combination with autologous bone grafting, but not dependent on application of additional rhBMP.
Mazzeti, Ana Lia; Diniz, Lívia de F; Gonçalves, Karolina R; Nascimento, Alvaro F S; Spósito, Pollyanna A F; Mosqueira, Vanessa C F; Machado-Coelho, George L L; Ribeiro, Isabela; Bahia, Maria T
2018-02-01
Benznidazole and nifurtimox-treatments regimens currently used in human are supported by very limited experimental data. This study was designed to evaluate the time and dose dependence for efficacy of the most important nitroheterocyclic drugs in use for Chagas disease. In order to evaluate time dependence, Y strain-infected mice received benznidazole for a total of 1, 3, 7, 10, 20, and 40 days. Treatment courses of 3-10-day were effective in clearing parasitaemia and suppressing mortality, but parasitological cure was not achieved. Extending the treatments to 20 or 40 days clearly improved benznidazole efficacy. The 20-day treatment induced cure in 57.1% of Y strain infections (partially drug resistant) but failed to cure Colombian strain infections (full drug resistant), while the 40-day treatment resulted in cure of 100% of Y and 50% of Colombian strain infected mice. The increased cure rates in T. cruzi infected animals that received nifurtimox for 40 days confirm the relationship between the length of treatment and efficacy. An improvement in efficacy was observed with increasing benznidazole doses; cure was verified in 28.6% (75 mg/kg), 57.1% (100 mg/kg) and 80% (300 mg/kg). Overall, these nonclinical study data provide evidence that the efficacy of benznidazole is dose and time dependent. These findings may be relevant for optimizing treatment of human Chagas disease. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
García-Barberena, Javier; Mutuberria, Amaia; Palacin, Luis G.; Sanz, Javier L.; Pereira, Daniel; Bernardos, Ana; Sanchez, Marcelino; Rocha, Alberto R.
2017-06-01
The National Renewable Energy Centre of Spain, CENER, and the Technology & Innovation area of ACS Cobra, as a result of their long term expertise in the CSP field, have developed a high-quality and high level of detail optical and thermal simulation software for the accurate evaluation of Molten Salts Solar Towers. The main purpose of this software is to make a step forward in the state-of-the-art of the Solar Towers simulation programs. Generally, these programs deal with the most critical systems of such plants, i.e. the solar field and the receiver, on an independent basis. Therefore, these programs typically neglect relevant aspects in the operation of the plant as heliostat aiming strategies, solar flux shapes onto the receiver, material physical and operational limitations, transient processes as preheating and secure cloud passing operating modes, and more. The modelling approach implemented in the developed program consists on effectively coupling detailed optical simulations of the heliostat field with also detailed and full-transient thermal simulations of the molten salts tube-based external receiver. The optical model is based on an accurate Monte Carlo ray-tracing method which solves the complete solar field by simulating each of the heliostats at once according to their specific layout in the field. In the thermal side, the tube-based cylindrical external receiver of a Molten Salts Solar Tower is modelled assuming one representative tube per panel, and implementing the specific connection layout of the panels as well as the internal receiver pipes. Each tube is longitudinally discretized and the transient energy and mass balances in the temperature dependent molten salts and steel tube models are solved. For this, a one dimensional radial heat transfer model based is used. The thermal model is completed with a detailed control and operation strategy module, able to represent the appropriate operation of the plant. An integration framework has been developed, helping ACS Cobra to adequately handle the optical and thermal coupled simulations. According to current results it can be concluded that the developed model has resulted in a powerful tool to improve the design and operation of future ACS Cobra's Molten Salts Solar Towers, since historical data based on its projects have been used for validation of the final tool.
Digital data detection and synchronization
NASA Technical Reports Server (NTRS)
Noack, T. L.; Morris, J. F.
1973-01-01
The primary accomplishments have been in the analysis and simulation of receivers and bit synchronizers. It has been discovered that tracking rate effects play, a rather fundamental role in both receiver and synchronizer performance, but that data relating to recorder time-base-error, for the proper characterization of this phenomenon, is in rather short supply. It is possible to obtain operationally useful tape recorder time-base-error data from high signal-to-noise ratio tapes using synchronizers with relatively wideband tracking loops. Low signal-to-noise ratio tapes examined in the same way would not be synchronizable. Additional areas of interest covered are receiver false lock, cycle slipping, and other unusual phenomena, which have been described to some extent in this and earlier reports and simulated during the study.
Introducing Real-Time AVHRR-APT Satellite Imagery in the Classroom Environment
ERIC Educational Resources Information Center
Moxey, Lucas; Tucker, Compton; Sloan, Jim; Chadwick, John
2004-01-01
A low-cost (US$350) satellite receiving station was assembled and operated within a classroom environment in Gainesville (Florida) on October 2001 for acquiring satellite data directly from the Advanced Very High Resolution Radiometer (AVHRR) satellites. The simplicity of the satellite signal makes this source of real-time satellite data readily…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kring, C.T.; Varma, V.K.; Jatko, W.B.
The US Army and Team Crusader (United Defense, Lockheed Martin Armament Systems, etc.) are developing the next generation howitzer, the Crusader. The development program includes an advanced, self-propelled liquid propellant howitzer and a companion resupply vehicle. The resupply vehicle is intended to rendezvous with the howitzer near the battlefront and replenish ammunition, fuel, and other material. The Army has recommended that Crusader incorporate new and innovative technologies to improve performance and safety. One conceptual design proposes a robotic resupply boom on the resupply vehicle to upload supplies to the howitzer. The resupply boom would normally be retracted inside the resupplymore » vehicle during transit. When the two vehicles are within range of the resupply boom, the boom would be extended to a receiving port on the howitzer. In order to reduce exposure to small arms fire or nuclear, biological, and chemical hazards, the crew would remain inside the resupply vehicle during the resupply operation. The process of extending the boom and linking with the receiving port is called docking. A boom operator would be designated to maneuver the boom into contact with the receiving port using a mechanical joystick. The docking operation depends greatly upon the skill of the boom operator to manipulate the boom into docking position. Computer simulations at the National Aeronautics and Space Administration have shown that computer-assisted or autonomous docking can improve the ability of the operator to dock safely and quickly. This document describes the present status of the Crusader Autonomous Docking System (CADS) implemented at Oak Ridge National laboratory (ORNL). The purpose of the CADS project is to determine the feasibility and performance limitations of vision systems to satisfy the autonomous docking requirements for Crusader and conduct a demonstration under controlled conditions.« less
Lee, W R; Kim, H S; Park, M K; Lee, J H; Kim, K H
2012-09-01
The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.
Kong, Yonggang; Yang, Xilin
2014-09-01
To evaluate the preemptive analgesia effects of both the parecoxib sodium and the pentazocine in patients undergoing nasal endoscopic surgery. In the randomized, double blind, controlled study, 120 patients undergoing septoplasty were divided into 3 groups (n = 40): group A received parecoxib 40 mg by muscle injection 30 min before the operation; group B received pentazocine 30 mg; group C received an equal volume of saline. The preemptive analgesia effect was evaluated with VAS scores which recorded at different time points. The proportion of participants using rescue analgesia after the operation were recorded as additional measures of preemptive analgesia. Intra-operative as well as the postoperative pain scores were less in the group A and group B than in the control group. Fewer participants required rescue medication after operation with parecoxib as well as pentazocine than placebo. However there were no difference in the preemptive effects between the group A and group B. Administration of both the parecoxib and pentazocine before the nasal endoscopic surgery can provide preemptive analgesia without serious adverse side effects that deserves popularization in the clinic.
Workload Capacity: A Response Time-Based Measure of Automation Dependence.
Yamani, Yusuke; McCarley, Jason S
2016-05-01
An experiment used the workload capacity measure C(t) to quantify the processing efficiency of human-automation teams and identify operators' automation usage strategies in a speeded decision task. Although response accuracy rates and related measures are often used to measure the influence of an automated decision aid on human performance, aids can also influence response speed. Mean response times (RTs), however, conflate the influence of the human operator and the automated aid on team performance and may mask changes in the operator's performance strategy under aided conditions. The present study used a measure of parallel processing efficiency, or workload capacity, derived from empirical RT distributions as a novel gauge of human-automation performance and automation dependence in a speeded task. Participants performed a speeded probabilistic decision task with and without the assistance of an automated aid. RT distributions were used to calculate two variants of a workload capacity measure, COR(t) and CAND(t). Capacity measures gave evidence that a diagnosis from the automated aid speeded human participants' responses, and that participants did not moderate their own decision times in anticipation of diagnoses from the aid. Workload capacity provides a sensitive and informative measure of human-automation performance and operators' automation dependence in speeded tasks. © 2016, Human Factors and Ergonomics Society.
Process mapping as a framework for performance improvement in emergency general surgery.
DeGirolamo, Kristin; D'Souza, Karan; Hall, William; Joos, Emilie; Garraway, Naisan; Sing, Chad Kim; McLaughlin, Patrick; Hameed, Morad
2017-12-01
Emergency general surgery conditions are often thought of as being too acute for the development of standardized approaches to quality improvement. However, process mapping, a concept that has been applied extensively in manufacturing quality improvement, is now being used in health care. The objective of this study was to create process maps for small bowel obstruction in an effort to identify potential areas for quality improvement. We used the American College of Surgeons Emergency General Surgery Quality Improvement Program pilot database to identify patients who received nonoperative or operative management of small bowel obstruction between March 2015 and March 2016. This database, patient charts and electronic health records were used to create process maps from the time of presentation to discharge. Eighty-eight patients with small bowel obstruction (33 operative; 55 nonoperative) were identified. Patients who received surgery had a complication rate of 32%. The processes of care from the time of presentation to the time of follow-up were highly elaborate and variable in terms of duration; however, the sequences of care were found to be consistent. We used data visualization strategies to identify bottlenecks in care, and they showed substantial variability in terms of operating room access. Variability in the operative care of small bowel obstruction is high and represents an important improvement opportunity in general surgery. Process mapping can identify common themes, even in acute care, and suggest specific performance improvement measures.
Process mapping as a framework for performance improvement in emergency general surgery.
DeGirolamo, Kristin; D'Souza, Karan; Hall, William; Joos, Emilie; Garraway, Naisan; Sing, Chad Kim; McLaughlin, Patrick; Hameed, Morad
2018-02-01
Emergency general surgery conditions are often thought of as being too acute for the development of standardized approaches to quality improvement. However, process mapping, a concept that has been applied extensively in manufacturing quality improvement, is now being used in health care. The objective of this study was to create process maps for small bowel obstruction in an effort to identify potential areas for quality improvement. We used the American College of Surgeons Emergency General Surgery Quality Improvement Program pilot database to identify patients who received nonoperative or operative management of small bowel obstruction between March 2015 and March 2016. This database, patient charts and electronic health records were used to create process maps from the time of presentation to discharge. Eighty-eight patients with small bowel obstruction (33 operative; 55 nonoperative) were identified. Patients who received surgery had a complication rate of 32%. The processes of care from the time of presentation to the time of follow-up were highly elaborate and variable in terms of duration; however, the sequences of care were found to be consistent. We used data visualization strategies to identify bottlenecks in care, and they showed substantial variability in terms of operating room access. Variability in the operative care of small bowel obstruction is high and represents an important improvement opportunity in general surgery. Process mapping can identify common themes, even in acute care, and suggest specific performance improvement measures.
Solar thermochemical processing system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegeng, Robert S.; Humble, Paul H.; Krishnan, Shankar
A solar thermochemical processing system is disclosed. The system includes a first unit operation for receiving concentrated solar energy. Heat from the solar energy is used to drive the first unit operation. The first unit operation also receives a first set of reactants and produces a first set of products. A second unit operation receives the first set of products from the first unit operation and produces a second set of products. A third unit operation receives heat from the second unit operation to produce a portion of the first set of reactants.
Lightner, Amy L; Tse, Chung Sang; Potter, D Dean; Moir, Christopher
2017-10-09
Recent studies have found vedolizumab to be an independent predictor of increased rates of postoperative complications and surgical site infections (SSIs) in adults with inflammatory bowel disease (IBD), but studies in the pediatric surgical population are lacking. We sought to determine the 30-day postoperative infectious complication rate among pediatric IBD patients who received vedolizumab within 12weeks of a major abdominal operation. A retrospective chart review was performed on pediatric IBD patients who underwent an abdominal operation between 5/20/2014 and 6/1/2017. The study cohort was comprised of pediatric patients (≤18years) who received vedolizumab within 12weeks prior to their abdominal operation. The control cohort was all patients operated on for IBD during the same time on anti-TNF therapy within 12weeks of their abdominal operation. Thirteen pediatric patients (5 female) received vedolizumab within 12weeks of an abdominal operation and 36 patients received anti TNF therapy (20 female). There were no differences in the vedolizumab and anti-TNF therapy with regard to sex, median age of diagnosis or operation, IBD type, body mass index (BMI), smoking status, diabetes mellitus (DM), preoperative serum laboratory values, steroid or immunomodulatory use. The number of biologics previously exposed to was significantly higher in the vedolizumab treated patients (p<0.0001). There were no significant differences in operative characteristics including laparoscopic versus open surgery, construction of an anastomosis, or diversion of an anastomosis. There were also no significant differences found in 30-day postoperative complications including nonsurgical site infections (SSIs), all SSIs, small bowel obstruction (SBO)/ileus, hospital readmission, or return to the operating room (ROR). There were four RORs in total: one in the vedolizumab group was for a missed enterotomy and stoma revision; three in the anti-TNF cohort were for ileostomy revisions. None of the thirteen pediatric patients who received vedolizumab within 12weeks of an abdominal operation experienced a 30-day postoperative SSI or non SSI infectious complication, suggesting that vedolizumab is safe in the perioperative period for pediatric patients with IBD. Owing to the small sample size, future study, perhaps multi-institutional, will be important to confirm these findings. Retrospective comparative study, Level III. Copyright © 2017 Elsevier Inc. All rights reserved.
Entanglement control in a superconducting qubit system by an electromagnetic field
NASA Astrophysics Data System (ADS)
Zhang, Y. Q.; Xu, J. B.
2011-08-01
By making use of the dynamical algebraic method we investigate a quantum system consisting of superconducting qubits interacting with data buses, where the qubits are driven by time-dependent electromagnetic field and obtain an explicit expression of time evolution operator. Furthermore, we explore the entanglement dynamics and the influence of the time-dependent electromagnetic field and the initial state on the entanglement sudden death and birth for the system. It is shown that the entanglement between the qubit and bus as well as the entanglement sudden death and birth can be controlled by the time-dependent electromagnetic field.
Nathaniel, Thomas I; Cochran, Thomas; Chaves, Jose; Fulmer, Eric; Sosa, Crystal; Yi, Sara; Fredwall, Megan; Sternberg, Shannon; Blackhurst, Dawn; Nelson, Alfred; Leacock, Rodney
2016-01-01
The objective of this study was to characterize the comorbidities in a population of patients with an acute ischaemic stroke, comparing patients that received recombinant tissue plasminogen activator (rt-PA) to those that did not receive rt-PA. In a retrospective sample of 663 patients admitted for acute ischaemic stroke, this study analysed the effects of co-morbid conditions in the use of rt-PA. It determined non-cerebrovascular risk factors (comorbidities) that differentiate patients who received rt-PA from those who did not receive rt-PA. Patients with a history of carotid stenosis, CHF and previous strokes are significantly (p < 0.05) associated with high risk of not receiving rt-PA. A significant number of patients with a history of hypertension and smoking received rt-PA (p < 0.05). The findings indicate that certain risk factors including carotid stenosis, CHF and previous stroke history impact the treatment of patients with acute ischaemic stroke, specifically the decision to administer rt-PA. Treatment with rt-PA is dependent on stroke severity and onset to treatment time, but the findings suggest that rt-PA use may also depend on patient comorbidities.
Real-Time Distributed Embedded Oscillator Operating Frequency Monitoring
NASA Technical Reports Server (NTRS)
Pollock, Julie; Oliver, Brett; Brickner, Christopher
2012-01-01
A document discusses the utilization of embedded clocks inside of operating network data links as an auxiliary clock source to satisfy local oscillator monitoring requirements. Modem network interfaces, typically serial network links, often contain embedded clocking information of very tight precision to recover data from the link. This embedded clocking data can be utilized by the receiving device to monitor the local oscillator for tolerance to required specifications, often important in high-integrity fault-tolerant applications. A device can utilize a received embedded clock to determine if the local or the remote device is out of tolerance by using a single link. The local device can determine if it is failing, assuming a single fault model, with two or more active links. Network fabric components, containing many operational links, can potentially determine faulty remote or local devices in the presence of multiple faults. Two methods of implementation are described. In one method, a recovered clock can be directly used to monitor the local clock as a direct replacement of an external local oscillator. This scheme is consistent with a general clock monitoring function whereby clock sources are clocking two counters and compared over a fixed interval of time. In another method, overflow/underflow conditions can be used to detect clock relationships for monitoring. These network interfaces often provide clock compensation circuitry to allow data to be transferred from the received (network) clock domain to the internal clock domain. This circuit could be modified to detect overflow/underflow conditions of the buffering required and report a fast or slow receive clock, respectively.
Liu, Jing-Hua; Zou, Yu; Chang, Wei; Wu, Jun; Zou, Yu; Xie, Yu-Chen; Lu, Yong-Ping; Wei, Jia
2017-01-01
We assessed liver fibrosis using real-time shear-wave elastography (SWE) combined with liver biopsy (LB) for patients with hepatitis B e antigen (HBeAg)-negative chronic hepatitis B (CHB) and alanine transaminase < 2 times the upper limit of normal and hepatitis B virus DNA < 2000 IU/ml. A total of 107 patients met the inclusion criteria. Real- ime SWE and ultrasoundassisted liver biopsies were consecutively performed. Fibrosis was staged according to the METAVIR scoring system. Analyses of receiver operating characteristic curve were performed to calculate the optimal area under the receiver operating characteristic curve for F0-F1 versus F2-F4, F0-F2 versus F3-F4, and F0-F3 versus F4 for real-time SWE. The most concurrent liver fibrosis degrees were between F1 and F2 for these HBeAg-negative CHB patients. Liver stiffness increased in parallel with the degree of liver fibrosis using SWE measurements. The area under the receiver operating characteristic curves was 0.881 (95% confidence interval [CI]: 0.704-1.000) for SWE (p = 0.004); 0.912 (95% CI: 0.836-0.987) for SWE (p = 0.000); 0.981 (95% CI: 0.956-1.000) for SWE (p = 0.000); 0.974 (95% CI: 0.936-1.000) for SWE (p = 0.000) when comparing F0 versus F1-F4, F0-F1 versus F2-F4, F0-F2 versus F3-F4, and F0-F3 versus F4, respectively. SWE has the advantage of providing an image of liver stiffness in real-time. As an alternative to LB, the development of all these noninvasive methods for dynamic evaluation of liver fibrosis will decrease the need for LB, making clinical care safer and more convenient for patients with liver diseases.
Weiss, Roger D; Potter, Jennifer Sharpe; Griffin, Margaret L; Provost, Scott E; Fitzmaurice, Garrett M; McDermott, Katherine A; Srisarajivakul, Emily N; Dodd, Dorian R; Dreifuss, Jessica A; McHugh, R Kathryn; Carroll, Kathleen M
2015-05-01
Despite the growing prevalence of prescription opioid dependence, longitudinal studies have not examined long-term treatment response. The current study examined outcomes over 42 months in the Prescription Opioid Addiction Treatment Study (POATS). POATS was a multi-site clinical trial lasting up to 9 months, examining different durations of buprenorphine-naloxone plus standard medical management for prescription opioid dependence, with participants randomized to receive or not receive additional opioid drug counseling. A subset of participants (N=375 of 653) enrolled in a follow-up study. Telephone interviews were administered approximately 18, 30, and 42 months after main-trial enrollment. Comparison of baseline characteristics by follow-up participation suggested few differences. At Month 42, much improvement was seen: 31.7% were abstinent from opioids and not on agonist therapy; 29.4% were receiving opioid agonist therapy, but met no symptom criteria for current opioid dependence; 7.5% were using illicit opioids while on agonist therapy; and the remaining 31.4% were using opioids without agonist therapy. Participants reporting a lifetime history of heroin use at baseline were more likely to meet DSM-IV criteria for opioid dependence at Month 42 (OR=4.56, 95% CI=1.29-16.04, p<.05). Engagement in agonist therapy was associated with a greater likelihood of illicit-opioid abstinence. Eight percent (n=27/338) used heroin for the first time during follow-up; 10.1% reported first-time injection heroin use. Long-term outcomes for those dependent on prescription opioids demonstrated clear improvement from baseline. However, a subset exhibited a worsening course, by initiating heroin use and/or injection opioid use. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Motaghinejad, Majid; Karimian, Seyed Morteza; Motaghinejad, Ozra; Shabab, Behnaz; Asadighaleni, Majid; Fatima, Sulail
2015-06-01
Chronic consumption of morphine induces physical dependency, anxiety, and neurodegeneration. In this study, morphine on its own has been used for the management of morphine-induced dependency, oxidative stress, and apoptosis. Forty-eight male rats were randomly divided into six groups. Rats in groups 1-5 were made morphine dependent by an increasing manner of morphine for 7 days (15-45 mg/kg). For the next 14 days, morphine was administered using the following regimen: (i) once daily 45 mg/kg (positive controls), (ii) the same dose at additional intervals (6 h longer than the previous intervals each time), (iii) 45 mg/kg of morphine at irregular intervals like of 12, 24, 36 h, (iv) decreasing dose once daily (every time 2.5 mg/kg less than the former dosage). Group 5 received 45 mg/kg of morphine and 10 mg/kg of SOD mimetic agent (M40401) injection per day. Group 6 (negative control) received saline solution only. On day 22, all animals received naloxone (3 mg/kg) and their Total Withdrawal Index (TWI) and blood cortisol levels were measured. After drug treatment, hippocampus cells were isolated, and oxidative, antioxidative, and apoptotic factors were evaluated. Various regimens of morphine reduced TWI, cortisol levels, Bax activity, caspase-3, caspase-9, TNF-α, and IL-1β and lipid peroxidation. In all treatment groups, GSH level, superoxide dismutase, glutathione peroxidase, and Bcl-2 activity were significantly increased. Furthermore, SOD mimetic agent c diminished morphine effect on SOD activity. Thus, varying the dosage regimen of morphine can reduce the severity of morphine-induced dependency and neurodegeneration. © 2015 Société Française de Pharmacologie et de Thérapeutique.
A Very Low Power MAC (VLPM) Protocol for Wireless Body Area Networks
Ullah, Niamat; Khan, Pervez; Kwak, Kyung Sup
2011-01-01
Wireless Body Area Networks (WBANs) consist of a limited number of battery operated nodes that are used to monitor the vital signs of a patient over long periods of time without restricting the patient’s movements. They are an easy and fast way to diagnose the patient’s status and to consult the doctor. Device as well as network lifetime are among the most important factors in a WBAN. Prolonging the lifetime of the WBAN strongly depends on controlling the energy consumption of sensor nodes. To achieve energy efficiency, low duty cycle MAC protocols are used, but for medical applications, especially in the case of pacemakers where data have time-limited relevance, these protocols increase latency which is highly undesirable and leads to system instability. In this paper, we propose a low power MAC protocol (VLPM) based on existing wakeup radio approaches which reduce energy consumption as well as improving the response time of a node. We categorize the traffic into uplink and downlink traffic. The nodes are equipped with both a low power wake-up transmitter and receiver. The low power wake-up receiver monitors the activity on channel all the time with a very low power and keeps the MCU (Micro Controller Unit) along with main radio in sleep mode. When a node [BN or BNC (BAN Coordinator)] wants to communicate with another node, it uses the low-power radio to send a wakeup packet, which will prompt the receiver to power up its primary radio to listen for the message that follows shortly. The wake-up packet contains the desired node’s ID along with some other information to let the targeted node to wake-up and take part in communication and let all other nodes to go to sleep mode quickly. The VLPM protocol is proposed for applications having low traffic conditions. For high traffic rates, optimization is needed. Analytical results show that the proposed protocol outperforms both synchronized and unsynchronized MAC protocols like T-MAC, SCP-MAC, B-MAC and X-MAC in terms of energy consumption and response time. PMID:22163818
Marshall Installs Receiving Antenna for Next-Generation Weather Satellites
2016-12-16
Technicians assemble a hefty segment of a new antenna system in this 30-second time-lapse video captured Dec. 16 at NASA's Marshall Space Flight Center. The high-performance ground station is designed to receive meteorological and space weather data from instruments flown on the National Oceanic and Atmospheric Administration's new, game-changing Geostationary Operational Environmental Satellite series. The six-meter dish antenna near Building 4316 expands the capacity of Marshall’s Earth Science Office to use real-time GOES observations for studies of Earth and to deliver new forecasting, warning and disaster response tools to partners around the world. (NASA/MSFC)
Scaling of Average Weighted Receiving Time on Double-Weighted Koch Networks
NASA Astrophysics Data System (ADS)
Dai, Meifeng; Ye, Dandan; Hou, Jie; Li, Xingyi
2015-03-01
In this paper, we introduce a model of the double-weighted Koch networks based on actual road networks depending on the two weight factors w,r ∈ (0, 1]. The double weights represent the capacity-flowing weight and the cost-traveling weight, respectively. Denote by wFij the capacity-flowing weight connecting the nodes i and j, and denote by wCij the cost-traveling weight connecting the nodes i and j. Let wFij be related to the weight factor w, and let wCij be related to the weight factor r. This paper assumes that the walker, at each step, starting from its current node, moves to any of its neighbors with probability proportional to the capacity-flowing weight of edge linking them. The weighted time for two adjacency nodes is the cost-traveling weight connecting the two nodes. We define the average weighted receiving time (AWRT) on the double-weighted Koch networks. The obtained result displays that in the large network, the AWRT grows as power-law function of the network order with the exponent, represented by θ(w,r) = ½ log2(1 + 3wr). We show that the AWRT exhibits a sublinear or linear dependence on network order. Thus, the double-weighted Koch networks are more efficient than classic Koch networks in receiving information.
Wu, Li-Tzy; Blazer, Dan G.; Woody, George E.; Burchett, Bruce; Yang, Chongming; Pan, Jeng-Jong; Ling, Walter
2011-01-01
Aim To address an urgent need for screening of substance use problems in medical settings, we examined substance-specific dependence criteria as potential brief screeners for the detection of patients with a substance use disorder (SUD). Methods The sample included 920 opioid-dependent adults who were recruited from outpatient treatment settings at 11 programs in 10 U.S. cities and who completed intake assessments of SUDs for a multisite study of the National Drug Abuse Treatment Clinical Trials Network (CTN003). Data were analyzed by factor analysis, item response theory (IRT), sensitivity, and specificity procedures. Results Across all substances (alcohol, amphetamines, cannabis, cocaine, sedatives), withdrawal was among the least prevalent symptoms, while taking large amounts and inability to cut down were among the most prevalent symptoms. Items closely related to the latent trait of a SUD showed good-to-high values of area under the receiver operating characteristic curve in identifying cases of a SUD; IRT-defined severe and less discriminative items exhibited low sensitivity in identifying cases of a SUD (withdrawal for all substances; time using for alcohol and sedatives; giving up activities for sedatives). Conclusions Study results suggest that withdrawal and time using are much less reliable indicators for a SUD than taking larger amounts than intended and inability to cut down and should be studied further for consideration in developing a simplified tool for screening patients for SUDs in medical settings. These findings have implications for the use of common health indicators in electronic health records systems to improve patient care. PMID:22204775
Determination of the cumulus size distribution from LANDSAT pictures
NASA Technical Reports Server (NTRS)
Karg, E.; Mueller, H.; Quenzel, H.
1983-01-01
Varying insolation causes undesirable thermic stress to the receiver of a solar power plant. The rapid change of insolation depends on the size distribution of the clouds; in order to measure these changes, it is suitable to determine typical cumulus size distributions. For this purpose, LANDSAT-images are adequate. Several examples of cumulus size distributions will be presented and their effects on the operation of a solar power plant are discussed.
NASA Technical Reports Server (NTRS)
Dryer, M.; Smith, Z. K.
1989-01-01
An MHD 2-1/2D, time-dependent model is used, together with observations of six solar flares during February 3-7, 1986, to demonstrate global, large-scale, compound disturbances in the solar wind over a wide range of heliolongitudes. This scenario is one that is likely to occur many times during the cruise, possibly even encounter, phases of the Multi-Comet Mission. It is suggested that a model such as this one should be tested with multi-spacecraft data (such as the MCM and earth-based probes) with several goals in view: (1) utility of the model for operational real-time forecasting of geomagnetic storms, and (2) scientific interpretation of certain forms of cometary activities and their possible association with solar-generated activity.
Difficulties in tracking the long-term global trend in tropical forest area.
Grainger, Alan
2008-01-15
The long-term trend in tropical forest area receives less scrutiny than the tropical deforestation rate. We show that constructing a reliable trend is difficult and evidence for decline is unclear, within the limits of errors involved in making global estimates. A time series for all tropical forest area, using data from Forest Resources Assessments (FRAs) of the United Nations Food and Agriculture Organization, is dominated by three successively corrected declining trends. Inconsistencies between these trends raise questions about their reliability, especially because differences seem to result as much from errors as from changes in statistical design and use of new data. A second time series for tropical moist forest area shows no apparent decline. The latter may be masked by the errors involved, but a "forest return" effect may also be operating, in which forest regeneration in some areas offsets deforestation (but not biodiversity loss) elsewhere. A better monitoring program is needed to give a more reliable trend. Scientists who use FRA data should check how the accuracy of their findings depends on errors in the data.
Analysis of High-Speed Vessels for Seventh Fleet Logistics Support
2005-03-01
station ships are operating with CSGs in the Sea of Japan (East Sea) and HSV2 is dedicated to service them. The last three station ships operate...with CSGs in the Yellow Sea (West Sea) and HSV1 is dedicated to service them. HSV1 is therefore servicing more customers, so each will receive fewer...hits. Aggravating this situation, 40nm separates the operating areas of HSV1 ’s three station ships, causing additional transit time for multiple CSG
Biomedical imaging with THz waves
NASA Astrophysics Data System (ADS)
Nguyen, Andrew
2010-03-01
We discuss biomedical imaging using radio waves operating in the terahertz (THz) range between 300 GHz to 3 THz. Particularly, we present the concept for two THz imaging systems. One system employs single antenna, transmitter and receiver operating over multi-THz-frequency simultaneously for sensing and imaging small areas of the human body or biological samples. Another system consists of multiple antennas, a transmitter, and multiple receivers operating over multi-THz-frequency capable of sensing and imaging simultaneously the whole body or large biological samples. Using THz waves for biomedical imaging promises unique and substantial medical benefits including extremely small medical devices, extraordinarily fine spatial resolution, and excellent contrast between images of diseased and healthy tissues. THz imaging is extremely attractive for detection of cancer in the early stages, sensing and imaging of tissues near the skin, and study of disease and its growth versus time.
Communications During Critical Mission Operations: Preparing for InSight's Landing on Mars
NASA Technical Reports Server (NTRS)
Asmar, Sami; Oudrhiri, Kamal; Kurtik, Susan; Weinstein-Weiss, Stacy
2014-01-01
Radio communications with deep space missions are often taken for granted due to the impressively successful records since, for decades, the technology and infrastructure have been developed for ground and flight systems to optimize telemetry and commanding. During mission-critical events such as the entry, descent, and landing of a spacecraft on the surface of Mars, the signal's level and frequency dynamics vary significantly and typically exceed the threshold of the budgeted links. The challenge is increased when spacecraft shed antennas with heat shields and other hardware during those risky few minutes. We have in the past successfully received signals on Earth during critical events even ones not intended for ground reception. These included the UHF signal transmitted by Curiosity to Marsorbiting assets. Since NASA's Deep Space Network does not operate in the UHF band, large radio telescopes around the world are utilized. The Australian CSIRO Parkes Radio Telescope supported the Curiosity UHF signal reception and DSN receivers, tools, and expertise were used in the process. In preparation for the InSight mission's landing on Mars in 2016, preparations are underway to support the UHF communications. This paper presents communication scenarios with radio telescopes, and the DSN receiver and tools. It also discusses the usefulness of the real-time information content for better response time by the mission team towards successful mission operations.
Interval Management with Spacing to Parallel Dependent Runways (IMSPIDR) Experiment and Results
NASA Technical Reports Server (NTRS)
Baxley, Brian T.; Swieringa, Kurt A.; Capron, William R.
2012-01-01
An area in aviation operations that may offer an increase in efficiency is the use of continuous descent arrivals (CDA), especially during dependent parallel runway operations. However, variations in aircraft descent angle and speed can cause inaccuracies in estimated time of arrival calculations, requiring an increase in the size of the buffer between aircraft. This in turn reduces airport throughput and limits the use of CDAs during high-density operations, particularly to dependent parallel runways. The Interval Management with Spacing to Parallel Dependent Runways (IMSPiDR) concept uses a trajectory-based spacing tool onboard the aircraft to achieve by the runway an air traffic control assigned spacing interval behind the previous aircraft. This paper describes the first ever experiment and results of this concept at NASA Langley. Pilots flew CDAs to the Dallas Fort-Worth airport using airspeed calculations from the spacing tool to achieve either a Required Time of Arrival (RTA) or Interval Management (IM) spacing interval at the runway threshold. Results indicate flight crews were able to land aircraft on the runway with a mean of 2 seconds and less than 4 seconds standard deviation of the air traffic control assigned time, even in the presence of forecast wind error and large time delay. Statistically significant differences in delivery precision and number of speed changes as a function of stream position were observed, however, there was no trend to the difference and the error did not increase during the operation. Two areas the flight crew indicated as not acceptable included the additional number of speed changes required during the wind shear event, and issuing an IM clearance via data link while at low altitude. A number of refinements and future spacing algorithm capabilities were also identified.
Lightner, Amy L; Mathis, Kellie L; Tse, Chung Sang; Pemberton, John H; Shen, Bo; Kochlar, Gursimran; Singh, Amandeep; Dulai, Parambir S; Eisenstein, Samuel; Sandborn, William J; Parry, Lisa; Stringfield, Sarah; Hudesman, David; Remzi, Feza; Loftus, Edward V
2018-03-19
Vedolizumab is now widely available for the treatment of moderate to severe ulcerative colitis (UC) and Crohn's disease (CD). We sought to quantify the rates of postoperative complications with preoperative vedolizumab compared with anti-tumor necrosis factor (anti-TNF) therapy. A multicenter retrospective review of adult inflammatory bowel disease (IBD) patients who underwent an abdominal operation between May 20, 2014, and December 31, 2015, was performed. The study cohort was comprised of patients who had received vedolizumab within 12 weeks of their abdominal operation, and the control cohort was IBD patients who had received anti-TNF therapy. A total of 146 patients received vedolizumab within 12 weeks before an abdominal operation (64% female; n = 93; median age, 33 years; range, 15-74 years), and 289 patients received anti-TNF therapy (49% female; n = 142; median age, 36 years; range, 17-73 years). Vedolizumab-treated patients were younger (P = 0.015) and were more likely to have taken corticosteroids (P < 0.01) within the 12 weeks before surgery. Vedolizumab-treated patients had a significantly increased risk of any postoperative surgical site infection (SSI; P < 0.01), superficial SSI (P < 0.01), deep space SSI (P = 0.39), and mucocutaneous separation of the diverting stoma (P < 0.00) as compared with patients taking anti-TNF therapy. On multivariate analysis, after adjusting for body mass index, steroids at the time of operation, and institution, exposure to vedolizumab remained a significant predictor of postoperative SSI (P < 0.01). We observed that vedolizumab-treated patients were at significantly increased risk of postoperative SSIs after a major abdominal operation, as compared with anti-TNF-treated patients.
Saccardi, Carlo; Gizzo, Salvatore; Vitagliano, Amerigo; Noventa, Marco; Micaglio, Massimo; Parotto, Matteo; Fiorese, Mauro; Litta, Pietro
2016-12-01
A proportion of patients undergoing laparoscopic gynecological surgery experiences excessive post-operative pain, which results in high rescue analgesic treatment and prolonged hospitalization. The aim of our study was to evaluate the efficacy of intraoperative topical ropivacaine in the control of post-operative pain in the first 48 h after operative laparoscopy for benign adnexal or uterine pathologies . We conducted a prospective, randomized, double-blind, placebo-controlled clinical trial. Patients received a standard dose of topical ropivacaine (injected at the three portal sites and atomized in the abdominal cavity) or placebo. The primary outcome was the evaluation of post-operative pain intensity 6 h after surgery. Secondary outcomes included the intensity of pain during the 48 h after surgery, shoulder tip pain and the request for rescue analgesics during the first 48 h after surgery, time to discharge from recovery room, time to mobilizing on the ward and time to return to daily activities. Patients were divided in two groups (Group_A: benign adnexal pathologies; Group_B: benign uterine diseases) and assigned to Subgroup_1 (receiving ropivacaine) and Subgroup_2 (receiving placebo). A total of 187 women were included: 93 in Group_A and 94 in Group_B. Forty-seven patients entered Subgroup_A1, 46 Subgroup_A2, 48 Subgroup_B1 and 46 Subgroup_B2. Subgroup_A1 experienced lower post-operative pain at 4 (p = 0.008) and 6 h (p = 0.001) as well as a faster return to daily activities (p = 0.01) in comparison with Subgroup_A2. Both Subgroup_A1 and Subgroup_B1 showed lower shoulder tip pain (respectively, p = 0.032 and p = 0.001) as well as shorter time to mobilizing on the ward after surgery (respectively, p = 0.001 and p = 0.01). The remaining variables analysis did not show significant results. Combined topical analgesia with ropivacaine could represent a new safe and effective tool in the control of post-operative pain in gynecological laparoscopic surgery. Given the greater benefits for adnexal surgery, this strategy may be more suitable for this class of patients.
Performance of correlation receivers in the presence of impulse noise.
NASA Technical Reports Server (NTRS)
Moore, J. D.; Houts, R. C.
1972-01-01
An impulse noise model, which assumes that each noise burst contains a randomly weighted version of a basic waveform, is used to derive the performance equations for a correlation receiver. The expected number of bit errors per noise burst is expressed as a function of the average signal energy, signal-set correlation coefficient, bit time, noise-weighting-factor variance and probability density function, and a time range function which depends on the crosscorrelation of the signal-set basis functions and the noise waveform. Unlike the performance results for additive white Gaussian noise, it is shown that the error performance for impulse noise is affected by the choice of signal-set basis function, and that Orthogonal signaling is not equivalent to On-Off signaling with the same average energy. Furthermore, it is demonstrated that the correlation-receiver error performance can be improved by inserting a properly specified nonlinear device prior to the receiver input.
Depth to the Moho in Southern New England and Eastern New York State from Seismic Receiver Functions
NASA Astrophysics Data System (ADS)
Cipar, J. J.; Ebel, J.
2016-12-01
The thickness of the Earth's crust is a fundamental parameter of geophysics and geology. The eastern New York/southern New England area encompasses the suture between the Paleozoic Appalachian orogen and the Proterozoic Laurentian craton. The recent installation of the IRIS Traveling Array (TA) in 2013-2014 coupled with stations operated by Boston College, Lamont-Doherty, and the US National Seismic Network provide an unprecedented source of data for seismic studies of crustal structure. We use the receiver functions complied by the EarthScope Automated Receiver Survey (EARS) to measure crustal thickness. Our procedure is to stack receiver functions (RFs) at each station using the correct moveout for the P-to-S conversion at the Moho (Ps phase). The time difference between the Ps and direct P arrivals (Ps-P time) is dependent on crustal thickness (H) and crustal S-wave velocity (Vs). To get an estimate of H, we assume that the mean P-wave velocity (Vp) in the crust is 6.5 km/s, and determine the range of Vs for a range of Poisson's ratio (0.23-0.27). We then solve for H using the P-Ps times measured from the RF stacks (at Δ=60°) and our estimates for Vp and Vs. The uncertainty in S-wave velocity translates to approximately ±2 km uncertainty in crustal thickness. Our crustal thickness map shows the well-known general progression from shallow crust near the Atlantic coast line ( 30 km) to deeper crust (45+ km) in the Laurentian craton. However, some detailed features become evident on our map. Most notably, thin crust ( 30 km) extends inland from the coast to the Connecticut River valley in eastern-central Massachusetts and southeastern New Hampshire. The Berkshire Hills of western Massachusetts have thick crust (43 km), reaching as deep as 46 km in extreme northwestern Massachusetts. Thus, there is a 13-15 km increase in crustal thickness over a distance of about 60 km. Currently, no stations are located in that zone. We find that the eastern Adirondacks have very thick crust, generally in excess of 45 km. Overall, our crustal thickness measurements are in excellent agreement with those from the 1988 Ontario-New York-New England refraction experiment (USGS) and from a local receiver function study conducted using closely-spaced stations (John Schuh, Boston College).
Simsek, Esen; Karaman, Yucel; Gonullu, Mustafa; Tekgul, Zeki; Cakmak, Meltem
2016-01-01
The incidence of perioperative respiratory complications and postoperative care unit recovery time investigated in patients with passive tobacco smoke exposure according to the degree of exposure. Total 270 patients ranging in age from 18 to 60 years with the ASA physical status I or II exposed and not exposed to passive tobacco smoke received general anesthesia for various elective surgical operations evaluated for the study. Patients divided into two groups as exposed and non-exposed to passive tobacco smoke, those exposed to passive smoke are also divided into two groups according to the degree of exposure. Patients taken to the postoperative care unit (PACU) at the end of the operation and monitorized until Modified Aldrete's Scores became 9 and more. Respiratory complications evaluated and recorded in intraoperative and postoperative period. A total of 251 patients were enrolled; 63 (25.1%) patients had airway complications, 11 (4.4%) had complications intraoperatively and 52 (20.7%) patients had complications postoperatively. There has been found significant relation with passive tobacco smoke exposure and high incidences of perioperative and postoperative respiratory complications. The risk of cough, desaturation and hypersecretion complications were found to be increased depending on the degree of exposure. There was significant relation between the degree of passive smoke exposure and the duration of PACU stay. Passive tobacco smoke exposed general anesthesia receiving patients also regarding to the degree of exposure having high rates of perioperative respiratory complications and prolongation of PACU stays when compared with unexposed patients. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Simsek, Esen; Karaman, Yucel; Gonullu, Mustafa; Tekgul, Zeki; Cakmak, Meltem
2016-01-01
The incidence of perioperative respiratory complications and postoperative care unit recovery time investigated in patients with passive tobacco smoke exposure according to the degree of exposure. Total 270 patients ranging in age from 18 to 60 years with the ASA physical status I or II exposed and not exposed to passive tobacco smoke received general anesthesia for various elective surgical operations evaluated for the study. Patients divided into two groups as exposed and non-exposed to passive tobacco smoke, those exposed to passive smoke are also divided into two groups according to the degree of exposure. Patients taken to the postoperative care unit (PACU) at the end of the operation and monitorized until Modified Aldrete's Scores became 9 and more. Respiratory complications evaluated and recorded in intraoperative and postoperative period. A total of 251 patients were enrolled; 63 (25.1%) patients had airway complications, 11 (4.4%) had complications intraoperatively and 52 (20.7%) patients had complications postoperatively. There has been found significant relation with passive tobacco smoke exposure and high incidences of perioperative and postoperative respiratory complications. The risk of cough, desaturation and hypersecretion complications were found to be increased depending on the degree of exposure. There was significant relation between the degree of passive smoke exposure and the duration of PACU stay. Passive tobacco smoke exposed general anesthesia receiving patients also regarding to the degree of exposure having high rates of perioperative respiratory complications and prolongation of PACU stays when compared with unexposed patients. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
2013-01-01
Background: Microvascular reconstruction for oncologic defects is a challenging and rewarding endeavor, and successful outcomes are dependent on a multitude of factors. This study represents lessons learned from a personal prospective experience with 100 consecutive free flaps. Methods: All patients’ medical records were reviewed for demographics, operative notes, and complications. Results: Overall 100 flaps were performed in 84 consecutive patients for reconstruction of breast, head and neck, trunk, and extremity defects. Nineteen patients underwent free flap breast reconstruction with 10 patients undergoing bilateral reconstruction and 2 patients receiving a bipedicle flap for reconstruction of a unilateral breast defect. Sixty-five free flaps were performed in 61 patients with 3 patients receiving 2 free flaps for reconstruction of extensive head and neck defects and 1 patient who required a second flap for partial flap loss. Trunk and extremity reconstruction was less common with 2 free flaps performed in each group. Overall, 19 patients (22.6%) developed complications and 14 required a return to the operating room. There were no flap losses in this cohort. Thorough preoperative evaluation and workup, meticulous surgical technique and intraoperative planning, and diligent postoperative monitoring and prompt intervention are critical for flap success. Conclusions: As a young plastic surgeon embarking in reconstructive plastic surgery at an academic institution, the challenges and dilemmas presented in the first year of practice have been daunting but also represent opportunities for learning and improvement. Skills and knowledge acquired from time, experience, and mentors are invaluable in optimizing outcomes in microvascular free flap reconstruction. PMID:25289221
Estimating traffic volumes for signalized intersections using connected vehicle data
Zheng, Jianfeng; Liu, Henry X.
2017-04-17
Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimatemore » traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.« less
Estimating traffic volumes for signalized intersections using connected vehicle data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Jianfeng; Liu, Henry X.
Recently connected vehicle (CV) technology has received significant attention thanks to active pilot deployments supported by the US Department of Transportation (USDOT). At signalized intersections, CVs may serve as mobile sensors, providing opportunities of reducing dependencies on conventional vehicle detectors for signal operation. However, most of the existing studies mainly focus on scenarios that penetration rates of CVs reach certain level, e.g., 25%, which may not be feasible in the near future. How to utilize data from a small number of CVs to improve traffic signal operation remains an open question. In this work, we develop an approach to estimatemore » traffic volume, a key input to many signal optimization algorithms, using GPS trajectory data from CV or navigation devices under low market penetration rates. To estimate traffic volumes, we model in this paper vehicle arrivals at signalized intersections as a time-dependent Poisson process, which can account for signal coordination. The estimation problem is formulated as a maximum likelihood problem given multiple observed trajectories from CVs approaching to the intersection. An expectation maximization (EM) procedure is derived to solve the estimation problem. Two case studies were conducted to validate our estimation algorithm. One uses the CV data from the Safety Pilot Model Deployment (SPMD) project, in which around 2800 CVs were deployed in the City of Ann Arbor, MI. The other uses vehicle trajectory data from users of a commercial navigation service in China. Mean absolute percentage error (MAPE) of the estimation is found to be 9–12%, based on benchmark data manually collected and data from loop detectors. Finally, considering the existing scale of CV deployments, the proposed approach could be of significant help to traffic management agencies for evaluating and operating traffic signals, paving the way of using CVs for detector-free signal operation in the future.« less
NASA Astrophysics Data System (ADS)
Terada, Takahide; Yamanaka, Kazuhiro; Suzuki, Atsuro; Tsubota, Yushi; Wu, Wenjing; Kawabata, Ken-ichi
2017-07-01
Ultrasound computed tomography (USCT) is promising for a non-invasive, painless, operator-independent and quantitative system for breast-cancer screening. Assembly error, production tolerance, and aging-degradation variations of the hardwire components, particularly of plane-wave-based USCT systems, may hamper cost effectiveness, precise imaging, and robust operation. The plane wave is transmitted from a ring-shaped transducer array for receiving the signal at a high signal-to-noise-ratio and fast aperture synthesis. There are four signal-delay components: response delays in the transmitters and receivers and propagation delays depending on the positions of the transducer elements and their directivity. We developed a highly precise calibration method for calibrating these delay components and evaluated it with our prototype plane-wave-based USCT system. Our calibration method was found to be effective in reducing delay errors. Gaps and curves were eliminated from the plane wave, and echo images of wires were sharpened in the entire imaging area.
Han, Jin; Wan, Hai-Tong; Yang, Jie-Hong; Zhang, Yu-Yan; Ge, Li-Jun; Bie, Xiao-Dong
2014-01-01
This study aimed to evaluate the effect of ligustrazine on levels of amino acid transmitters in the extracellular fluid of striatum following cerebral ischemia/reperfusion (I/R) in male Sprague-Dawley rats. A microdialysis cannula guide was implanted into the right striatum. After recovery, animals underwent a sham operation or middle cerebral artery occlusion (MCAO). Those that developed cerebral ischemia after MCAO were randomized to receive propylene glycol salt water and ligustrazine respectively. Striatal fluid samples were collected from all animals at 15-min intervals after treatment and were subjected to HPLC analysis of aspartic acid, glutamic acid, taurine, and γ-amino butyric acid. Upon the last sample collection, animals were sacrificed and brain tissue specimens were collected for triphenyltetrazolium chloride staining and NeuN staining. Compared with the sham operation, MCAO induced significant neurological deficits and increased striatal concentrations of the four neurotransmitters assessed in a time-dependent manner (P < 0.01). Ligustrazine effectively attenuated the detrimental effects of MCAO on the brain. These observations suggest that ligustrazine as a novel cerebral infarction-protective agent may have potential clinical implications for I/R-related brain damage.
Correlation of Windspeed and Antarctic Surface Roughness
NASA Astrophysics Data System (ADS)
Stockham, Mark; Anita Collaboration
2015-04-01
When electromagnetic waves interact with a media interface the transmitted and reflected portions of the incoming wave depend on the incident angle of the wave and wavelength (as well as the material properties of the media). The roughness of the surface of Antarctica affects the radio frequency signals received by airborne experiments, such as the balloon-borne experiment ANITA (ANtarctic Impulsive Transient Antenna) which observes the reflected radio waves from cosmic ray-induced extensive air showers (EAS). Roughness of a given scale can cause decoherence of the reflected signal and is an important effect to understand when estimating the amplitude of the incoming wave based on the reflected wave. It is challenging to get a survey of surface roughness over many of the areas that these experiments are likely to pass over. Correlating historical wind speed records with statistical roughness as observed by the backscatter of satellite [Rémy F, Parouty S. Remote Sensing. 2009] and airborne experiments operating at different frequencies can possibly be used to predict time-dependent surface roughness with surface wind speed as the input. These correlations will be presented for a variety of areas on the Antarctic ice shelf. NASA Grant NNX11AC47G.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... GSA Program Numbers Department of Agriculture: Farm Operating Loans 10.406 Farm Ownership Loans 10.407...: Federal Employment for Disadvantaged Youth—Part-Time (Stay-in-School Program) 27.003 Federal Employment...
Code of Federal Regulations, 2013 CFR
2013-01-01
.... GSA Program Numbers Department of Agriculture: Farm Operating Loans 10.406 Farm Ownership Loans 10.407...: Federal Employment for Disadvantaged Youth—Part-Time (Stay-in-School Program) 27.003 Federal Employment...
Code of Federal Regulations, 2014 CFR
2014-01-01
.... GSA Program Numbers Department of Agriculture: Farm Operating Loans 10.406 Farm Ownership Loans 10.407...: Federal Employment for Disadvantaged Youth—Part-Time (Stay-in-School Program) 27.003 Federal Employment...
Code of Federal Regulations, 2012 CFR
2012-01-01
.... GSA Program Numbers Department of Agriculture: Farm Operating Loans 10.406 Farm Ownership Loans 10.407...: Federal Employment for Disadvantaged Youth—Part-Time (Stay-in-School Program) 27.003 Federal Employment...
Architecture for a 1-GHz Digital RADAR
NASA Technical Reports Server (NTRS)
Mallik, Udayan
2011-01-01
An architecture for a Direct RF-digitization Type Digital Mode RADAR was developed at GSFC in 2008. Two variations of a basic architecture were developed for use on RADAR imaging missions using aircraft and spacecraft. Both systems can operate with a pulse repetition rate up to 10 MHz with 8 received RF samples per pulse repetition interval, or at up to 19 kHz with 4K received RF samples per pulse repetition interval. The first design describes a computer architecture for a Continuous Mode RADAR transceiver with a real-time signal processing and display architecture. The architecture can operate at a high pulse repetition rate without interruption for an infinite amount of time. The second design describes a smaller and less costly burst mode RADAR that can transceive high pulse repetition rate RF signals without interruption for up to 37 seconds. The burst-mode RADAR was designed to operate on an off-line signal processing paradigm. The temporal distribution of RF samples acquired and reported to the RADAR processor remains uniform and free of distortion in both proposed architectures. The majority of the RADAR's electronics is implemented in digital CMOS (complementary metal oxide semiconductor), and analog circuits are restricted to signal amplification operations and analog to digital conversion. An implementation of the proposed systems will create a 1-GHz, Direct RF-digitization Type, L-Band Digital RADAR--the highest band achievable for Nyquist Rate, Direct RF-digitization Systems that do not implement an electronic IF downsample stage (after the receiver signal amplification stage), using commercially available off-the-shelf integrated circuits.
Nursing research on a first aid model of double personnel for major burn patients.
Wu, Weiwei; Shi, Kai; Jin, Zhenghua; Liu, Shuang; Cai, Duo; Zhao, Jingchun; Chi, Cheng; Yu, Jiaao
2015-03-01
This study explored the effect of a first aid model employing two nurses on the efficient rescue operation time and the efficient resuscitation time for major burn patients. A two-nurse model of first aid was designed for major burn patients. The model includes a division of labor between the first aid nurses and the re-organization of emergency carts. The clinical effectiveness of the process was examined in a retrospective chart review of 156 cases of major burn patients, experiencing shock and low blood volume, who were admitted to the intensive care unit of the department of burn surgery between November 2009 and June 2013. Of the 156 major burn cases, 87 patients who received first aid using the double personnel model were assigned to the test group and the 69 patients who received first aid using the standard first aid model were assigned to the control group. The efficient rescue operation time and the efficient resuscitation time for the patients were compared between the two groups. Student's t tests were used to the compare the mean difference between the groups. Statistically significant differences between the two groups were found on both measures (P's < 0.05), with the test group having lower times than the control group. The efficient rescue operation time was 14.90 ± 3.31 min in the test group and 30.42 ± 5.65 min in the control group. The efficient resuscitation time was 7.4 ± 3.2 h in the test group and 9.5 ± 2.7 h in the control group. A two-nurse first aid model based on scientifically validated procedures and a reasonable division of labor can shorten the efficient rescue operation time and the efficient resuscitation time for major burn patients. Given these findings, the model appears to be worthy of clinical application.
Willatzen, M
1999-01-01
A general set of modeling equations for lossless one-dimensional multilayer ultrasound transducers is presented based on first principles. In particular, a direct relationship between ultrasound transducer results and the underlying physical principles of electroacoustics is given. As such, the model may provide better physical understanding for designers not fully versed in electrical circuits theory or in linear system analyses. The model is suitable for time-domain analysis and monofrequency design. Special attention is given to the determination of the time-dependent voltage across the receiver electrodes subject to a general voltage input, but information on any (dynamic) variable of interest is provided. The basic equations governing the dynamics of the multilayer structure acting as transmitter as well as receiver are solved by Fourier analysis and by imposing continuity of velocity and pressure between layers. Sound transmission between the two piezoelectric circuits is assumed to take place in a water bath such that the Rayleigh equation can be used to obtain the incoming pressure at the receiver aperture from the acceleration of the opposing transmitter aperture. Comparison with experimental results is possible by allowing coupling to external electric impedances. A numerical test case using a multilayered 1-MHz transducer for flow meter applications was considered and good agreement with experiments was obtained in terms of voltage signals. The transducer contains a half-wavelength stainless steel layer needed to resist corrosion, the ability to operate at temperatures in a wide range from 20 to 150 degrees Celsius, resistance to impact from flowing particles in the medium, high pressure or vacuum, and pH values up to 10 in some locations. The influence of epoxy glue and grease acoustic coupling layers-between the piezoceramics and the stainless steel layer-in the range from 1 to 70 mum was examined. It was shown that, for the same layer thickness, epoxy glue is preferred as compared with grease, both in terms of signal shapes and amplitudes. Finally, inclusion of appropriate electric impedances in the transmitter and receiver circuits is found to affect signal pulses strongly.
NASA Astrophysics Data System (ADS)
Vasquez Padilla, Ricardo; Soo Too, Yen Chean; Benito, Regano; McNaughton, Robbie; Stein, Wes
2018-01-01
In this paper, optimisation of the supercritical CO? Brayton cycles integrated with a solar receiver, which provides heat input to the cycle, was performed. Four S-CO? Brayton cycle configurations were analysed and optimum operating conditions were obtained by using a multi-objective thermodynamic optimisation. Four different sets, each including two objective parameters, were considered individually. The individual multi-objective optimisation was performed by using Non-dominated Sorting Genetic Algorithm. The effect of reheating, solar receiver pressure drop and cycle parameters on the overall exergy and cycle thermal efficiency was analysed. The results showed that, for all configurations, the overall exergy efficiency of the solarised systems achieved at maximum value between 700°C and 750°C and the optimum value is adversely affected by the solar receiver pressure drop. In addition, the optimum cycle high pressure was in the range of 24.2-25.9 MPa, depending on the configurations and reheat condition.
Pandit, Jaideep J; Tavare, Aniket
2011-07-01
It is important that a surgical list is planned to utilise as much of the scheduled time as possible while not over-running, because this can lead to cancellation of operations. We wished to assess whether, theoretically, the known duration of individual operations could be used quantitatively to predict the likely duration of the operating list. In a university hospital setting, we first assessed the extent to which the current ad-hoc method of operating list planning was able to match the scheduled operating list times for 153 consecutive historical lists. Using receiver operating curve analysis, we assessed the ability of an alternative method to predict operating list duration for the same operating lists. This method uses a simple formula: the sum of individual operation times and a pooled standard deviation of these times. We used the operating list duration estimated from this formula to generate a probability that the operating list would finish within its scheduled time. Finally, we applied the simple formula prospectively to 150 operating lists, 'shadowing' the current ad-hoc method, to confirm the predictive ability of the formula. The ad-hoc method was very poor at planning: 50% of historical operating lists were under-booked and 37% over-booked. In contrast, the simple formula predicted the correct outcome (under-run or over-run) for 76% of these operating lists. The calculated probability that a planned series of operations will over-run or under-run was found useful in developing an algorithm to adjust the planned cases optimally. In the prospective series, 65% of operating lists were over-booked and 10% were under-booked. The formula predicted the correct outcome for 84% of operating lists. A simple quantitative method of estimating operating list duration for a series of operations leads to an algorithm (readily created on an Excel spreadsheet, http://links.lww.com/EJA/A19) that can potentially improve operating list planning.
Exploitation of Ubiquitous Wi-Fi Devices as Building Blocks for Improvised Motion Detection Systems.
Soldovieri, Francesco; Gennarelli, Gianluca
2016-02-27
This article deals with a feasibility study on the detection of human movements in indoor scenarios based on radio signal strength variations. The sensing principle exploits the fact that the human body interacts with wireless signals, introducing variations of the radiowave fields due to shadowing and multipath phenomena. As a result, human motion can be inferred from fluctuations of radiowave power collected by a receiving terminal. In this paper, we investigate the potentialities of widely available wireless communication devices in order to develop an improvised motion detection system (IMDS). Experimental tests are performed in an indoor environment by using a smartphone as a Wi-Fi access point and a laptop with dedicated software as a receiver. Simple detection strategies tailored for real-time operation are implemented to process the received signal strength measurements. The achieved results confirm the potentialities of the simple system here proposed to reliably detect human motion in operational conditions.
Improved Spacecraft Tracking and Navigation Using a Portable Radio Science Receiver
NASA Technical Reports Server (NTRS)
Soriano, Melissa; Jacobs, Christopher; Navarro, Robert; Naudet, Charles; Rogstad, Stephen; White, Leslie; Finley, Susan; Goodhart, Charles; Sigman, Elliott; Trinh, Joseph
2013-01-01
The Portable Radio Science Receiver (PRSR) is a suitcase-sized open-loop digital receiver designed to be small and easy to transport so that it can be deployed quickly and easily anywhere in the world. The PRSR digitizes, downconverts, and filters using custom hardware, firmware, and software. Up to 16 channels can be independently configured and recorded with a total data rate of up to 256 Mbps. The design and implementation of the system's hardware, firmware, and software is described. To minimize costs and time to deployment, our design leveraged elements of the hardware, firmware, and software designs from the existing full-sized operational (non-portable) Radio Science Receivers (RSR) and Wideband VLBI Science Receivers (WVSR), which have successfully supported flagship NASA deep space missions at all Deep Space Network (DSN) sites. We discuss a demonstration of the PRSR using VLBI, with one part per billion angular resolution: 1 nano-radian / 200 ?as synthesized beam. This is the highest resolution astronomical instrument ever operated solely from the Southern Hemisphere. Preliminary results from two sites are presented, including the European Space Agency (ESA) sites at Cebreros, Spain and Malargue, Argentina. Malargue's South American location is of special interest because it greatly improves the geometric coverage for spacecraft navigation in the Southern Hemisphere and will for the first time provide coverage to the 1/4 of the range of declination that has been excluded from reference frame work at Ka-band.
Unfair and Anomalous Evolutionary Dynamics from Fluctuating Payoffs.
Stollmeier, Frank; Nagler, Jan
2018-02-02
Evolution occurs in populations of reproducing individuals. Reproduction depends on the payoff a strategy receives. The payoff depends on the environment that may change over time, on intrinsic uncertainties, and on other sources of randomness. These temporal variations in the payoffs can affect which traits evolve. Understanding evolutionary game dynamics that are affected by varying payoffs remains difficult. Here we study the impact of arbitrary amplitudes and covariances of temporally varying payoffs on the dynamics. The evolutionary dynamics may be "unfair," meaning that, on average, two coexisting strategies may persistently receive different payoffs. This mechanism can induce an anomalous coexistence of cooperators and defectors in the prisoner's dilemma, and an unexpected selection reversal in the hawk-dove game.
Unfair and Anomalous Evolutionary Dynamics from Fluctuating Payoffs
NASA Astrophysics Data System (ADS)
Stollmeier, Frank; Nagler, Jan
2018-02-01
Evolution occurs in populations of reproducing individuals. Reproduction depends on the payoff a strategy receives. The payoff depends on the environment that may change over time, on intrinsic uncertainties, and on other sources of randomness. These temporal variations in the payoffs can affect which traits evolve. Understanding evolutionary game dynamics that are affected by varying payoffs remains difficult. Here we study the impact of arbitrary amplitudes and covariances of temporally varying payoffs on the dynamics. The evolutionary dynamics may be "unfair," meaning that, on average, two coexisting strategies may persistently receive different payoffs. This mechanism can induce an anomalous coexistence of cooperators and defectors in the prisoner's dilemma, and an unexpected selection reversal in the hawk-dove game.
Development of High Data Rate Acoustic Multiple-Input/Multiple-Output Modems
2015-09-30
communication capabilities of underwater platforms and facilitate real-time adaptive operations in the ocean. OBJECTIVES The ...signaling at the transmitter and low-complexity time reversal processing at the receiver. APPROACH Underwater acoustic (UWA) communication is useful...digital communications in shallow water environments. The advancement has direct impacts on defense appliations since underwater acoustic modems
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-06
... eliminate the references to the real-time market in the calculation of congestion charges that FTR holders receive and direct the Respondent to allocate incremental real-time transmission congestion charges to all... of The Respondent's Open Access Transmission Tariff and Operating Agreement (OA), as related to the...
Precise time and time interval applications to electric power systems
NASA Technical Reports Server (NTRS)
Wilson, Robert E.
1992-01-01
There are many applications of precise time and time interval (frequency) in operating modern electric power systems. Many generators and customer loads are operated in parallel. The reliable transfer of electrical power to the consumer partly depends on measuring power system frequency consistently in many locations. The internal oscillators in the widely dispersed frequency measuring units must be syntonized. Elaborate protection and control systems guard the high voltage equipment from short and open circuits. For the highest reliability of electric service, engineers need to study all control system operations. Precise timekeeping networks aid in the analysis of power system operations by synchronizing the clocks on recording instruments. Utility engineers want to reproduce events that caused loss of service to customers. Precise timekeeping networks can synchronize protective relay test-sets. For dependable electrical service, all generators and large motors must remain close to speed synchronism. The stable response of a power system to perturbations is critical to continuity of electrical service. Research shows that measurement of the power system state vector can aid in the monitoring and control of system stability. If power system operators know that a lightning storm is approaching a critical transmission line or transformer, they can modify operating strategies. Knowledge of the location of a short circuit fault can speed the re-energizing of a transmission line. One fault location technique requires clocks synchronized to one microsecond. Current research seeks to find out if one microsecond timekeeping can aid and improve power system control and operation.
JPRS Report, Telecommunications
1991-11-29
this problem exists in Great Britain, too. U.S. productions very often appear on cinema and televi- sion screens—U.S. mass production, if I can call...data receiving station by the time the country’s own satellite is put into orbit in 1994. Malaysian Science, Technology, and Environment Minister...Law Hieng Ding said the country would then no longer have to depend on the receiving station in Thailand. He said the Malaysian Remote Sensing Centre
Khalil-Khalili, Masoumeh; Rashidy-Pour, Ali; Bandegi, Ahmad Reza; Yousefi, Behpoor; Jorjani, Hassan; Miladi-Gorji, Hossein
2018-03-06
This study examined the effects of systemic administration of the TrkB receptor antagonist (ANA-12) on the severity of physical and psychological dependence and morphine-induced locomotor sensitization, the ventral tegmental area (VTA)-nucleus accumbens (NAc) BDNF levels in morphine-dependent and withdrawn rats. Rats were injected with bi-daily doses (10 mg/kg, at 12 h intervals) of morphine for 10 days. Then, rats were tested for naloxone-precipitated morphine withdrawal signs, the anxiety (the elevated plus maze-EPM) after the last morphine injection and injection of ANA12 (ip). Also, morphine-induced locomotor sensitization was evaluated after morphine challenge followed by an injection of ANA-12 in morphine-withdrawn rats. The VTA-NAc BDNF levels were assessed in morphine-dependent and withdrawn rats. The overall Gellert-Holtzman score was significantly higher in morphine-dependent rats receiving ANA-12 than in those receiving saline. Also, the percentage of time spent in the open arms in control and morphine-dependent rats receiving ANA-12 were higher compared to the Cont/Sal and D/Sal rats, respectively. There was no significant difference in the locomotor activity and the VTA-NAc BDNF levels between D/Sal/morphine and D/ANA-12/morphine groups after morphine withdrawal. We conclude that the systemic administration of ANA-12 exacerbates the severity of physical dependence on morphine and partially attenuates the anxiety-like behavior in morphine-dependent rats. However, ANA-12 did not affect morphine-induced locomotor sensitization and the VTA-NAc BDNF levels in morphine-dependent and withdrawn rats. Copyright © 2017 Elsevier B.V. All rights reserved.
Ada 9X Project Report, A Study of Implementation-Dependent Pragmas and Attributes in Ada
1989-11-01
here communicatons with the vendor were often required to firmly establish the behavior of some implementation-dependent features CMU-SEI-SR-89-19 3 2.2...compilers), by potential market penetration (percent coverage of all surveyed implementations), and by cross-compiler influence (percentage of cross...operations in the context of a tightly integrated development environment, specific underlying operating system services (beneath the Ada run- time kernel
Basic Principles of Sea and Swell. A Programmed Unit of Instruction.
ERIC Educational Resources Information Center
Marine Maritime Academy, Castine.
Whether in carrier flight operations, resupply at sea, antisubmarine warfare, amphibious landings, sea search and rescue, or ship routing, sea conditions, at the place and time the operation is being conducted, become vitally important. The success or failure of any operation being conducted in an ocean environment is greatly dependent upon the…
Interferometer using a 3 × 3 coupler and Faraday mirrors
NASA Astrophysics Data System (ADS)
Breguet, J.; Gisin, N.
1995-06-01
A new interferometric setup using a 3 \\times 3 coupler and two Faraday mirrors is presented. It has the advantages of being built only with passive components, of freedom from the polarization fading problem, and of operation with a LED. It is well suited for sensing time-dependent signals and does not depend on reciprocal or nonreciprocal constant perturbations.
NASA Technical Reports Server (NTRS)
Oaks, O. J.; Reid, Wilson; Wright, James; Duffey, Christopher; Williams, Charles; Warren, Hugh; Zeh, Tom; Buisson, James
1996-01-01
The Naval Research Laboratory (NRL) in the development of timing systems for remote locations, had a technical requirement for a Y code (SA/AS) Global Positioning System (GPS) precise time transfer receiver (TTR) which could be used both in a stationary mode or mobile mode. A contract was awarded to the Stanford Telecommunication Corporation (STEL) to build such a device. The Eastern Range (ER) als had a requirement for such a receiver and entered into the contract with NRL for the procurement of additional receivers. The Moving Vehicle Experiment (MVE) described in this paper is the first in situ test of the STEL Model 5401C Time Transfer System in both stationary and mobile operations. The primary objective of the MVE was to test the timing accuracy of the newly developed GPS TTR aboard a moving vessel. To accomplish this objective, a joint experiment was performed with personnel from NRL and the er at the Atlantic Undersea Test and Evaluation Center (AUTEC) test range at Andros Island. Results and discussion of the test are presented in this paper.
NASA Technical Reports Server (NTRS)
Grubb, Matt
2016-01-01
The NASA Operational Simulator for Small Satellites (NOS3) is a suite of tools to aid in areas such as software development, integration test (IT), mission operations training, verification and validation (VV), and software systems check-out. NOS3 provides a software development environment, a multi-target build system, an operator interface-ground station, dynamics and environment simulations, and software-based hardware models. NOS3 enables the development of flight software (FSW) early in the project life cycle, when access to hardware is typically not available. For small satellites there are extensive lead times on many of the commercial-off-the-shelf (COTS) components as well as limited funding for engineering test units (ETU). Considering the difficulty of providing a hardware test-bed to each developer tester, hardware models are modeled based upon characteristic data or manufacturers data sheets for each individual component. The fidelity of each hardware models is such that FSW executes unaware that physical hardware is not present. This allows binaries to be compiled for both the simulation environment, and the flight computer, without changing the FSW source code. For hardware models that provide data dependent on the environment, such as a GPS receiver or magnetometer, an open-source tool from NASA GSFC (42 Spacecraft Simulation) is used to provide the necessary data. The underlying infrastructure used to transfer messages between FSW and the hardware models can also be used to monitor, intercept, and inject messages, which has proven to be beneficial for VV of larger missions such as James Webb Space Telescope (JWST). As hardware is procured, drivers can be added to the environment to enable hardware-in-the-loop (HWIL) testing. When strict time synchronization is not vital, any number of combinations of hardware components and software-based models can be tested. The open-source operator interface used in NOS3 is COSMOS from Ball Aerospace. For testing, plug-ins are implemented in COSMOS to control the NOS3 simulations, while the command and telemetry tools available in COSMOS are used to communicate with FSW. NOS3 is actively being used for FSW development and component testing of the Simulation-to-Flight 1 (STF-1) CubeSat. As NOS3 matures, hardware models have been added for common CubeSat components such as Novatel GPS receivers, ClydeSpace electrical power systems and batteries, ISISpace antenna systems, etc. In the future, NASA IVV plans to distribute NOS3 to other CubeSat developers and release the suite to the open-source community.
Gaussian mixture models as flux prediction method for central receivers
NASA Astrophysics Data System (ADS)
Grobler, Annemarie; Gauché, Paul; Smit, Willie
2016-05-01
Flux prediction methods are crucial to the design and operation of central receiver systems. Current methods such as the circular and elliptical (bivariate) Gaussian prediction methods are often used in field layout design and aiming strategies. For experimental or small central receiver systems, the flux profile of a single heliostat often deviates significantly from the circular and elliptical Gaussian models. Therefore a novel method of flux prediction was developed by incorporating the fitting of Gaussian mixture models onto flux profiles produced by flux measurement or ray tracing. A method was also developed to predict the Gaussian mixture model parameters of a single heliostat for a given time using image processing. Recording the predicted parameters in a database ensures that more accurate predictions are made in a shorter time frame.
Prototype Parts of a Digital Beam-Forming Wide-Band Receiver
NASA Technical Reports Server (NTRS)
Kaplan, Steven B.; Pylov, Sergey V.; Pambianchi, Michael
2003-01-01
Some prototype parts of a digital beamforming (DBF) receiver that would operate at multigigahertz carrier frequencies have been developed. The beam-forming algorithm in a DBF receiver processes signals from multiple antenna elements with appropriate time delays and weighting factors chosen to enhance the reception of signals from a specific direction while suppressing signals from other directions. Such a receiver would be used in the directional reception of weak wideband signals -- for example, spread-spectrum signals from a low-power transmitter on an Earth-orbiting spacecraft or other distant source. The prototype parts include superconducting components on integrated-circuit chips, and a multichip module (MCM), within which the chips are to be packaged and connected via special inter-chip-communication circuits. The design and the underlying principle of operation are based on the use of the rapid single-flux quantum (RSFQ) family of logic circuits to obtain the required processing speed and signal-to-noise ratio. RSFQ circuits are superconducting circuits that exploit the Josephson effect. They are well suited for this application, having been proven to perform well in some circuits at frequencies above 100 GHz. In order to maintain the superconductivity needed for proper functioning of the RSFQ circuits, the MCM must be kept in a cryogenic environment during operation.
Puvanesarajah, Varun; Amin, Raj; Qureshi, Rabia; Shafiq, Babar; Stein, Ben; Hassanzadeh, Hamid; Yarboro, Seth
2018-06-01
Proximal femur fractures are one of the most common fractures observed in dialysis-dependent patients. Given the large comorbidity burden present in this patient population, more information is needed regarding post-operative outcomes. The goal of this study was to assess morbidity and mortality following operative fixation of femoral neck fractures in the dialysis-dependent elderly. The full set of medicare data from 2005 to 2014 was retrospectively analyzed. Elderly patients with femoral neck fractures were selected. Patients were stratified based on dialysis dependence. Post-operative morbidity and mortality outcomes were compared between the two populations. Adjusted odds were calculated to determine the effect of dialysis dependence on outcomes. A total of 320,629 patients met the inclusion criteria. Of dialysis-dependent patients, 1504 patients underwent internal fixation and 2662 underwent arthroplasty. For both surgical cohorts, dialysis dependence was found to be associated with at least 1.9 times greater odds of mortality within 1 and 2 years post-operatively. Blood transfusions within 90 days and infections within 2 years were significantly increased in the dialysis-dependent study cohort. Dialysis dependence alone did not contribute to increased mechanical failure or major medical complications. Regardless of the surgery performed, dialysis dependence is a significant risk factor for major post-surgical morbidity and mortality after operative treatment of femoral neck fractures in this population. Increased mechanical failure in the internal fixation group was not observed. The increased risk associated with caring for this population should be understood when considering surgical intervention and counseling patients.
Bayesian semiparametric estimation of covariate-dependent ROC curves
Rodríguez, Abel; Martínez, Julissa C.
2014-01-01
Receiver operating characteristic (ROC) curves are widely used to measure the discriminating power of medical tests and other classification procedures. In many practical applications, the performance of these procedures can depend on covariates such as age, naturally leading to a collection of curves associated with different covariate levels. This paper develops a Bayesian heteroscedastic semiparametric regression model and applies it to the estimation of covariate-dependent ROC curves. More specifically, our approach uses Gaussian process priors to model the conditional mean and conditional variance of the biomarker of interest for each of the populations under study. The model is illustrated through an application to the evaluation of prostate-specific antigen for the diagnosis of prostate cancer, which contrasts the performance of our model against alternative models. PMID:24174579
NASA Astrophysics Data System (ADS)
Wilde-Piorko, M.; Polkowski, M.
2016-12-01
Seismic wave travel time calculation is the most common numerical operation in seismology. The most efficient is travel time calculation in 1D velocity model - for given source, receiver depths and angular distance time is calculated within fraction of a second. Unfortunately, in most cases 1D is not enough to encounter differentiating local and regional structures. Whenever possible travel time through 3D velocity model has to be calculated. It can be achieved using ray calculation or time propagation in space. While single ray path calculation is quick it is complicated to find the ray path that connects source with the receiver. Time propagation in space using Fast Marching Method seems more efficient in most cases, especially when there are multiple receivers. In this presentation final release of a Python module pySeismicFMM is presented - simple and very efficient tool for calculating travel time from sources to receivers. Calculation requires regular 2D or 3D velocity grid either in Cartesian or geographic coordinates. On desktop class computer calculation speed is 200k grid cells per second. Calculation has to be performed once for every source location and provides travel time to all receivers. pySeismicFMM is free and open source. Development of this tool is a part of authors PhD thesis. Source code of pySeismicFMM will be published before Fall Meeting. National Science Centre Poland provided financial support for this work via NCN grant DEC-2011/02/A/ST10/00284.
Qiu, Meiguang; Shi, Zhanjun; Xiao, Jun; Zhang, Xuming; Ling, Shishui; Ling, Hao
2016-12-01
The purpose of this study is to evaluate the potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures versus conventional treatment modalities. A retrospective reviewed study compared 86 cases which received surgical treatment between June 2009 and May 2013 to 76 cases which received conservative treatment between January 2006 and May 2009. The patients were divided into the flail chest ( n = 38) and multiple non-flail rib fracture groups ( n = 124). In the flail chest group, the mechanical ventilation time, ICU monitoring time, tracheostomies, thoracic deformity, and impaired pulmonary function and return to full-time employment were compared. In the multiple non-flail rib fracture group, fracture healing, visual analog scale (VAS) pain score, inpatient length of stay, atelectatic, pulmonary complications, and normal activity-returning time were compared. Patients in the flail chest operative fixation group had significantly shorter ICU stay, decreased ventilator requirements, fewer tracheostomies, less thoracic deformity and impaired pulmonary function, and more returned to full-time employment. Patients in the multiple non-flail rib fracture operative fixation had shorter hospital stay, less pain, earlier return to normal activity, more fracture healing, less atelectasis, and fewer pulmonary infections. This study demonstrates the potential benefits of surgical stabilization of flail chest and multiple non-flail rib fractures with plate fixation. When compared with conventional conservative management, operatively managed patients demonstrated improved clinical outcomes.
Mission Operations and Information Management Area Spacecraft Monitoring and Control Working Group
NASA Technical Reports Server (NTRS)
Lokerson, Donald C. (Editor)
2005-01-01
Working group goals for this year are: Goal 1. Due to many review comments the green books will be updated and available for re-review by CCSDS. Submission of green books to CCSDS for approval. Goal 2.Initial set of 4 new drafts of the red books as following: SM&C protocol: update with received comments. SM&C common services: update with received comments and expand the service specification. SM&C core services: update with received comments and expand the service the information model. SM&C time services: (target objective): produce initial draft following template of core services.
Analysis of impact of “strong DC and weak AC” on receiving-end power system
NASA Astrophysics Data System (ADS)
Wang, Qiang; Li, Tianran; Yang, Pengcheng
2018-02-01
The rapid development of UHVDC transmission project has brought abundant power supply to the receiving-end power system area, but also many security and stability problems. This paper summarizes four elements that affect the strength of AC system, and then simulates the most basic two-terminal single-pole UHV transmission system by MATLAB/Simulink. It analyses the impact of receiving-end AC power system strength on real-time power, frequency and voltage. Finally, in view of operation risk of “strong DC and weak AC”, this paper puts forward three countermeasures.
NASA Astrophysics Data System (ADS)
Snow, Trevor M.
As analog-to-digital (ADC) and digital-to-analog conversion (DAC) technologies become cheaper and digital processing capabilities improve, phased array systems with digital transceivers at every element will become more commonplace. These architectures offer greater capability over traditional analog systems and enable advanced applications such as multiple-input, multiple-output (MIMO) communications, adaptive beamforming, space-time adaptive processing (STAP), and MIMO for radar. Capabilities for such systems are still limited by the need for isolating self-interference from transmitters at co-located receivers. The typical approach of time-sharing the antenna aperture between transmitters and receivers works but leaves the receivers blind for a period of time. For full-duplex operation, some systems use separate frequency bands for transmission and reception, but these require fixed filtering which reduces the system's ability to adapt to its environment and is also an inefficient use of spectral resources. To that end, tunable, high quality-factor filters are used for sub-band isolation and protect receivers while allowing open reception at other frequencies. For more flexibility, another emergent area of related research has focused on co-located spatial isolation using multiple antennas and direct injection of interference cancellation signals into receivers, which enables same-frequency full-duplex operation. With all these methods, self-interference must be reduced by an amount that prevents saturation of the ADC. Intermodulation products generated in the receiver in this process can potentially be problematic, as certain intermodulation products may appear to come from a particular angle and cohere in the beamformer. This work explores various digital phased array architectures and the how the flexibility afforded by an all-digital beamforming architecture, layered with other methods of isolation, can be used to reduce self-interference within the system. Specifically, digital control of coupled energy into receiving elements for planar and cylindrical array symmetries can be significantly reduced using near-field nulling, optimization of transmission frequencies for particular steering angles, and optimization of phase weights over restricted sets, without major impacts to the far-field performance of the system. Finally, a method for reducing in-band intermodulation that would ordinarily cohere in a system's receive beamformer is demonstrated using parallel cross-linearization of adjacent digital receivers in a phased array.
Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong
2017-07-01
The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery.In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared.The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively.PELD operation was superior in terms of operation time, bleeding volume, recovery period, and financial support, if compared with lumbar internal fixation operation. Radiographic parameters reflect lumber structure changes, which could be observed immediately after surgery in both methods; however, the recoveries on nerve function and pain relief required a longer time, especially after PLIF operation.
How early should VATS be performed for retained haemothorax in blunt chest trauma?
Lin, Hsing-Lin; Huang, Wen-Yen; Yang, Chyan; Chou, Shih-Min; Chiang, Hsin-I; Kuo, Liang-Chi; Lin, Tsung-Ying; Chou, Yi-Pin
2014-09-01
Blunt chest injury is not uncommon in trauma patients. Haemothorax and pneumothorax may occur in these patients, and some of them will develop retained pleural collections. Video-assisted thoracoscopic surgery (VATS) has become an appropriate method for treating these complications, but the optimal timing for performing the surgery and its effects on outcome are not clearly understood. In this study, a total of 136 patients who received VATS for the management of retained haemothorax from January 2003 to December 2011 were retrospectively enrolled. All patients had blunt chest injuries and 90% had associated injuries in more than two sites. The time from trauma to operation was recorded and the patients were divided into three groups: 2-3 days (Group 1), 4-6 days (Group 2), and 7 or more days (Group 3). Clinical outcomes such as the length of stay (LOS) at the hospital and intensive care unit (ICU), and duration of ventilator and chest tube use were all recorded and compared between groups. The mean duration from trauma to operation was 5.9 days. All demographic characteristics showed no statistical differences between groups. Compared with other groups, Group 3 had higher rates of positive microbial cultures in pleural collections and sputum, longer duration of chest tube insertion and ventilator use. Lengths of hospital and ICU stay in Groups 1 and 2 showed no statistical difference, but were longer in Group 3. The frequency of repeated VATS was lower in Group 1 but without statistically significant difference. This study indicated that an early VATS intervention would decrease chest infection. It also reduced the duration of ventilator dependency. The clinical outcomes were significantly better for patients receiving VATS within 3 days under intensive care. In this study, we suggested that VATS might be delayed by associated injuries, but should not exceed 6 days after trauma. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Dosimetry during intramedullary nailing of the tibia.
Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George
2009-10-01
Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.
Integration Of Space Weather Into Space Situational Awareness
NASA Astrophysics Data System (ADS)
Reeves, G.
2010-09-01
Rapid assessment of space weather effects on satellites is a critical step in anomaly resolution and satellite threat assessment. That step, however, is often hindered by a number of factors including timely collection and delivery of space weather data and the inherent complexity of space weather information. As part of a larger, integrated space situational awareness program, Los Alamos National Laboratory has developed prototype operational space weather tools that run in real time and present operators with customized, user-specific information. The Dynamic Radiation Environment Assimilation Model (DREAM) focuses on the penetrating radiation environment from natural or nuclear-produced radiation belts. The penetrating radiation environment is highly dynamic and highly orbitdependent. Operators often must rely only on line plots of 2 MeV electron flux from the NOAA geosynchronous GOES satellites which is then assumed to be representative of the environment at the satellite of interest. DREAM uses data assimilation to produce a global, real-time, energy dependent specification. User tools are built around a distributed service oriented architecture (SOA) which allows operators to select any satellite from the space catalog and examine the environment for that specific satellite and time of interest. Depending on the application operators may need to examine instantaneous dose rates and/or dose accumulated over various lengths of time. Further, different energy thresholds can be selected depending on the shielding on the satellite or instrument of interest. In order to rapidly assess the probability that space weather effects, the current conditions can be compared against the historical distribution of radiation levels for that orbit. In the simplest operation a user would select a satellite and time of interest and immediately see if the environmental conditions were typical, elevated, or extreme based on how often those conditions occur in that orbit. This allows users to rapidly rule in or out environmental causes of anomalies. The same user interface can also allow users to drill down for more detailed quantitative information. DREAM can be run either from a distributed web-based user interface or as a stand-alone application for secure operations. We will discuss the underlying structure of the DREAM model and demonstrate the user interface that we have developed. We will also discuss future development plans for DREAM and how the same paradigm can be applied to integrating other space environment information into operational SSA systems.
Archer, Charles J.; Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.
2014-08-12
Endpoint-based parallel data processing in a parallel active messaging interface (`PAMI`) of a parallel computer, the PAMI composed of data communications endpoints, each endpoint including a specification of data communications parameters for a thread of execution on a compute node, including specifications of a client, a context, and a task, the compute nodes coupled for data communications through the PAMI, including establishing a data communications geometry, the geometry specifying, for tasks representing processes of execution of the parallel application, a set of endpoints that are used in collective operations of the PAMI including a plurality of endpoints for one of the tasks; receiving in endpoints of the geometry an instruction for a collective operation; and executing the instruction for a collective operation through the endpoints in dependence upon the geometry, including dividing data communications operations among the plurality of endpoints for one of the tasks.
2008-02-27
between the PHY layer and for example a host PC computer . The PC wants to generate and receive a sequence of data packets. The PC may also want to send...the testbed is quite similar. Given the intense computational requirements of SVD and other matrix mode operations needed to support eigen spreading a...platform for real time operation. This task is probably the major challenge in the development of the testbed. All compute intensive tasks will be
Optically triggered fire set/detonator system
Chase, Jay B.; Pincosy, Philip A.; Chato, Donna M.; Kirbie, Hugh; James, Glen F.
2007-03-20
The present invention is directed to a system having a plurality of capacitor discharge units (CDUs) that includes electrical bridge type detonators operatively coupled to respective explosives. A pulse charging circuit is adapted to provide a voltage for each respective capacitor in each CDU. Such capacitors are discharged through the electrical bridge type detonators upon receiving an optical signal to detonate respective operatively coupled explosives at substantially the same time.
NASA Astrophysics Data System (ADS)
Wissner-Gross, Alexander D.; Sullivan, Timothy M.
2013-05-01
We present a novel "participatory telerobotics" system that generalizes the existing concept of participatory sensing to include real-time teleoperation and telepresence by treating humans with mobile devices as ad-hoc telerobots. In our approach, operators or analysts first choose a desired location for remote surveillance or activity from a live geographic map and are then automatically connected via a coordination server to the nearest available trusted human. That human's device is then activated and begins recording and streaming back to the operator a live audiovisual feed for telepresence, while allowing the operator in turn to request complex teleoperative motions or actions from the human. Supported action requests currently include walking, running, leaning, and turning, all with controllable magnitudes and directions. Compliance with requests is automatically measured and scored in real time by fusing information received from the device's onboard sensors, including its accelerometers, gyroscope, magnetometer, GPS receiver, and cameras. Streams of action requests are visually presented by each device to its human in the form of an augmented reality game that rewards prompt physical compliance while remaining tolerant of network latency. Because of its ability to interactively elicit physical knowledge and operations through ad-hoc collaboration, we anticipate that our participatory telerobotics system will have immediate applications in the intelligence, retail, healthcare, security, and travel industries.
Digital Intermediate Frequency Receiver Module For Use In Airborne Sar Applications
Tise, Bertice L.; Dubbert, Dale F.
2005-03-08
A digital IF receiver (DRX) module directly compatible with advanced radar systems such as synthetic aperture radar (SAR) systems. The DRX can combine a 1 G-Sample/sec 8-bit ADC with high-speed digital signal processor, such as high gate-count FPGA technology or ASICs to realize a wideband IF receiver. DSP operations implemented in the DRX can include quadrature demodulation and multi-rate, variable-bandwidth IF filtering. Pulse-to-pulse (Doppler domain) filtering can also be implemented in the form of a presummer (accumulator) and an azimuth prefilter. An out of band noise source can be employed to provide a dither signal to the ADC, and later be removed by digital signal processing. Both the range and Doppler domain filtering operations can be implemented using a unique pane architecture which allows on-the-fly selection of the filter decimation factor, and hence, the filter bandwidth. The DRX module can include a standard VME-64 interface for control, status, and programming. An interface can provide phase history data to the real-time image formation processors. A third front-panel data port (FPDP) interface can send wide bandwidth, raw phase histories to a real-time phase history recorder for ground processing.
Lightner, A L; McKenna, N P; Tse, C S; Raffals, L E; Loftus, E V; Mathis, K L
2018-03-01
Up to 80% of patients with Crohn's disease require an abdominal operation in their lifetime. As the use of vedolizumab is increasing for the treatment of Crohn's disease, it is important to understand its potential association with post-operative complications. We sought to compare 30-day postoperative infectious complication rate among vedolizumab-treated Crohn's disease patients vs those who had received TNFα inhibitors or no biologic therapy. A retrospective review of all Crohn's disease patients who received vedolizumab within 12 weeks of a major abdominal or pelvic operation was performed. Two control cohorts consisted of Crohn's disease patients treated with TNFα inhibitors or no biologic therapy. One hundred Crohn's disease patients received vedolizumab within 12 weeks of an abdominal operation. Vedolizumab-treated patients underwent an equivalent rate of laparoscopic surgery (P = .25), had fewer anastomoses performed (P = .0002), and had equally frequent diversion in the setting of anastomoses (P = .47). Thirty-two vedolizumab-treated patients experienced postoperative infectious complications (32%), 26 of which were surgical site infections (26%). The vedolizumab-treated group experienced no difference in nonsurgical site infections (6% vs 5% anti-TNFα and 2% nonbiologic; P = .34), but significantly higher rates of surgical site infections (26% vs 8% and 11%; P < .001). On univariate and multivariate analysis, exposure to vedolizumab remained a significant predictor of postoperative surgical site infection (P < .001 and P = .002). Twenty-six per cent of Crohn's disease patients who received vedolizumab within 12 weeks prior to a major abdominal operation experienced a 30-day postoperative surgical site infection, significantly higher than that of patients receiving TNFα inhibitors or no biologic therapy. Vedolizumab within 12 weeks of surgery remained a predictor of 30-day postoperative surgical site infection on multivariable analysis. While vedolizumab-treated Crohn's disease patients may be a sicker cohort of patients, it is important to consider these findings with regard to preoperative counselling, operative timing and primary closure of wounds. © 2017 John Wiley & Sons Ltd.
Ebinesan, Ananthan D; Sarai, Bhupinder S; Walley, Gayle; Bridgman, Stephen; Maffulli, Nicola
2006-07-31
Nearly 20,000 patients per year in the UK receive total knee arthroplasty (TKA). One of the problems faced by the health services of many developed countries is the length of time patients spend waiting for elective treatment. We therefore report the results of a study in which the Salisbury Priority Scoring System (SPSS) was used by both the surgeon and their patients to ascertain whether there were differences between the surgeon generated and patient generated Salisbury Priority Scores. The Salisbury Priority Scoring System (SPSS) was used to assign relative priority to patients with knee osteoarthritis as part of a randomised controlled trial comparing the standard medial parapatellar approach versus the sub-vastus approach in TKA. The operating surgeons and each patient completed the SPSS at the same pre-assessment clinic. The SPSS assesses four criteria, namely progression of disease, pain or distress, disability or dependence on others, and loss of usual occupation. Crosstabs and agreement measures (Cohen's kappa) were performed. Overall, the four SPSS criteria showed a kappa value of 0.526, 0.796, 0.813, and 0.820, respectively, showing moderate to very good agreement between the patient and the operating consultant. Male patients showed better agreement than female patients. The Salisbury Priority Scoring System is a good means of assessing patients' needs in relation to elective surgery, with high agreement between the patient and the operating surgeon.
Sokolowski, Michel B C; Abramson, Charles I; Craig, David Philip Arthur
2012-09-01
This study examines the effect of ethanol (EtOH) on continuous reinforcement schedules in the free-flying honeybee (Apis mellifera L.). As fermented nectars may be encountered naturally in the environment, we designed an experiment combining the tools of laboratory research with minimal disturbance to the natural life of honeybees. Twenty-five honeybees were trained to fly from their colonies to a fully automated operant chamber with head poking as the operant response. Load size, intervisit interval, and interresponse times (IRTs) served as the dependent variables and were monitored over the course of a daily training session consisting of many visits. Experimental bees were tested using an ABA design in which sucrose only was administered during condition A and a 5% EtOH sucrose solution was administered during condition B. Control bees received sucrose solution only. Most bees continued to forage after EtOH introduction. EtOH significantly reduced the load size and the intervisit interval with no significant effect on IRTs. However, a look on individual data shows large individual differences suggesting the existence of different kinds of behavioral phenotypes linked to EtOH consumption and effects. Our results contribute to the study of EtOH consumption as a normal phenomenon in an ecological context and open the door to schedule-controlled drug self-administration studies in honeybees. Copyright © 2012 by the Research Society on Alcoholism.
Sham, Jonathan G; Simianu, Vlad V; Wright, Andrew S; Stewart, Skye D; Alloosh, Mouhamad; Sturek, Michael; Cummings, David E; Flum, David R
2014-01-01
Roux-en-Y gastric bypass (RYGB) is the most common bariatric operation; however, the mechanism underlying the profound weight-independent effects on glucose homeostasis remains unclear. Large animal models of naturally occurring insulin resistance (IR), which have been lacking, would provide opportunities to elucidate such mechanisms. Ossabaw miniature swine naturally exhibit many features that may be useful in evaluating the anti diabetic effects of bariatric surgery. Glucose homeostasis was studied in 53 Ossabaw swine. Thirty-two received an obesogenic diet and were randomized to RYGB, gastrojejunostomy (GJ), gastrojejunostomy with duodenal exclusion (GJD), or Sham operations. Intravenous glucose tolerance tests and standardized meal tolerance tests were performed prior to, 1, 2, and 8 weeks after surgery and at a single time-point for regular diet control pigs. High-calorie-fed Ossabaws weighed more and had greater IR than regular diet controls, though only 70% developed IR. All operations caused weight-loss-independent improvement in IR, though only in pigs with high baseline IR. Only RYGB induced weight loss and decreased IR in the majority of pigs, as well as increasing AUCinsulin/AUCglucose. Similar to humans, Ossabaw swine exhibit both obesity-dependent and obesity-independent IR. RYGB promoted weight loss, IR improvement, and increased AUCinsulin/AUCglucose, compared to the smaller changes following GJ and GJD, suggesting a combination of upper and lower gut mechanisms in improving glucose homeostasis.
2017-06-06
OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for...Geophysical Mapping, Electromagnetic Induction, Instrument Verification Strip, Time Domain Electromagnetic, Unexploded Ordnance 16. SECURITY...Munitions Response QA Quality Assurance QC Quality Control ROC Receiver Operating Characteristic RTK Real- time Kinematic s Second SNR
A method of operation scheduling based on video transcoding for cluster equipment
NASA Astrophysics Data System (ADS)
Zhou, Haojie; Yan, Chun
2018-04-01
Because of the cluster technology in real-time video transcoding device, the application of facing the massive growth in the number of video assignments and resolution and bit rate of diversity, task scheduling algorithm, and analyze the current mainstream of cluster for real-time video transcoding equipment characteristics of the cluster, combination with the characteristics of the cluster equipment task delay scheduling algorithm is proposed. This algorithm enables the cluster to get better performance in the generation of the job queue and the lower part of the job queue when receiving the operation instruction. In the end, a small real-time video transcode cluster is constructed to analyze the calculation ability, running time, resource occupation and other aspects of various algorithms in operation scheduling. The experimental results show that compared with traditional clustering task scheduling algorithm, task delay scheduling algorithm has more flexible and efficient characteristics.
[Cost analysis for navigation in knee endoprosthetics].
Cerha, O; Kirschner, S; Günther, K-P; Lützner, J
2009-12-01
Total knee arthroplasty (TKA) is one of the most frequent procedures in orthopaedic surgery. The outcome depends on a range of factors including alignment of the leg and the positioning of the implant in addition to patient-associated factors. Computer-assisted navigation systems can improve the restoration of a neutral leg alignment. This procedure has been established especially in Europe and North America. The additional expenses are not reimbursed in the German DRG system (Diagnosis Related Groups). In the present study a cost analysis of computer-assisted TKA compared to the conventional technique was performed. The acquisition expenses of various navigation systems (5 and 10 year depreciation), annual costs for maintenance and software updates as well as the accompanying costs per operation (consumables, additional operating time) were considered. The additional operating time was determined on the basis of a meta-analysis according to the current literature. Situations with 25, 50, 100, 200 and 500 computer-assisted TKAs per year were simulated. The amount of the incremental costs of the computer-assisted TKA depends mainly on the annual volume and the additional operating time. A relevant decrease of the incremental costs was detected between 50 and 100 procedures per year. In a model with 100 computer-assisted TKAs per year an additional operating time of 14 mins and a 10 year depreciation of the investment costs, the incremental expenses amount to
Shapiro, F; Zurakowski, D; Bui, T; Darras, B T
2014-01-01
We determined the frequency, rate and extent of development of scoliosis (coronal plane deformity) in wheelchair-dependent patients with Duchenne muscular dystrophy (DMD) who were not receiving steroid treatment. We also assessed kyphosis and lordosis (sagittal plane deformity). The extent of scoliosis was assessed on sitting anteroposterior (AP) spinal radiographs in 88 consecutive non-ambulatory patients with DMD. Radiographs were studied from the time the patients became wheelchair-dependent until the time of spinal fusion, or the latest assessment if surgery was not undertaken. Progression was estimated using a longitudinal mixed-model regression analysis to handle repeated measurements. Scoliosis ≥ 10° occurred in 85 of 88 patients (97%), ≥ 20° in 78 of 88 (89%) and ≥ 30° in 66 of 88 patients (75%). The fitted longitudinal model revealed that time in a wheelchair was a highly significant predictor of the magnitude of the curve, independent of the age of the patient (p < 0.001). Scoliosis developed in virtually all DMD patients not receiving steroids once they became wheelchair-dependent, and the degree of deformity deteriorated over time. In general, scoliosis increased at a constant rate, beginning at the time of wheelchair-dependency (p < 0.001). In some there was no scoliosis for as long as three years after dependency, but scoliosis then developed and increased at a constant rate. Some patients showed a rapid increase in the rate of progression of the curve after a few years - the clinical phenomenon of a rapidly collapsing curve over a few months. A sagittal plane kyphotic deformity was seen in 37 of 60 patients (62%) with appropriate radiographs, with 23 (38%) showing lumbar lordosis (16 (27%) abnormal and seven (11%) normal). This study provides a baseline to assess the effects of steroids and other forms of treatment on the natural history of scoliosis in patients with DMD, and an approach to assessing spinal deformity in the coronal and sagittal planes in wheelchair-dependent patients with other neuromuscular disorders.
Chian, Chih-Feng; Hwang, Yi-Ting; Terng, Harn-Jing; Lee, Shih-Chun; Chao, Tsui-Yi; Chang, Hung; Ho, Ching-Liang; Wu, Yi-Ying; Perng, Wann-Cherng
2016-08-02
Peripheral blood mononuclear cell (PBMC)-derived gene signatures were investigated for their potential use in the early detection of non-small cell lung cancer (NSCLC). In our study, 187 patients with NSCLC and 310 age- and gender-matched controls, and an independent set containing 29 patients for validation were included. Eight significant NSCLC-associated genes were identified, including DUSP6, EIF2S3, GRB2, MDM2, NF1, POLDIP2, RNF4, and WEE1. The logistic model containing these significant markers was able to distinguish subjects with NSCLC from controls with an excellent performance, 80.7% sensitivity, 90.6% specificity, and an area under the receiver operating characteristic curve (AUC) of 0.924. Repeated random sub-sampling for 100 times was used to validate the performance of classification training models with an average AUC of 0.92. Additional cross-validation using the independent set resulted in the sensitivity 75.86%. Furthermore, six age/gender-dependent genes: CPEB4, EIF2S3, GRB2, MCM4, RNF4, and STAT2 were identified using age and gender stratification approach. STAT2 and WEE1 were explored as stage-dependent using stage-stratified subpopulation. We conclude that these logistic models using different signatures for total and stratified samples are potential complementary tools for assessing the risk of NSCLC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nishimura, Takahiro, E-mail: t-nishimura@ist.osaka-u.ac.jp; Fujii, Ryo; Ogura, Yusuke
Molecular logic circuits represent a promising technology for observation and manipulation of biological systems at the molecular level. However, the implementation of molecular logic circuits for temporal and programmable operation remains challenging. In this paper, we demonstrate an optically controllable logic circuit that uses fluorescence resonance energy transfer (FRET) for signaling. The FRET-based signaling process is modulated by both molecular and optical inputs. Based on the distance dependence of FRET, the FRET pathways required to execute molecular logic operations are formed on a DNA nanostructure as a circuit based on its molecular inputs. In addition, the FRET pathways on themore » DNA nanostructure are controlled optically, using photoswitching fluorescent molecules to instruct the execution of the desired operation and the related timings. The behavior of the circuit can thus be controlled using external optical signals. As an example, a molecular logic circuit capable of executing two different logic operations was studied. The circuit contains functional DNAs and a DNA scaffold to construct two FRET routes for executing Input 1 AND Input 2 and Input 1 AND NOT Input 3 operations on molecular inputs. The circuit produced the correct outputs with all possible combinations of the inputs by following the light signals. Moreover, the operation execution timings were controlled based on light irradiation and the circuit responded to time-dependent inputs. The experimental results demonstrate that the circuit changes the output for the required operations following the input of temporal light signals.« less
Time operators in stroboscopic wave-packet basis and the time scales in tunneling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bokes, P.
2011-03-15
We demonstrate that the time operator that measures the time of arrival of a quantum particle into a chosen state can be defined as a self-adjoint quantum-mechanical operator using periodic boundary conditions and applied to wave functions in energy representation. The time becomes quantized into discrete eigenvalues; and the eigenstates of the time operator, i.e., the stroboscopic wave packets introduced recently [Phys. Rev. Lett. 101, 046402 (2008)], form an orthogonal system of states. The formalism provides simple physical interpretation of the time-measurement process and direct construction of normalized, positive definite probability distribution for the quantized values of the arrival time.more » The average value of the time is equal to the phase time but in general depends on the choice of zero time eigenstate, whereas the uncertainty of the average is related to the traversal time and is independent of this choice. The general formalism is applied to a particle tunneling through a resonant tunneling barrier in one dimension.« less
QPROP: A Schrödinger-solver for intense laser atom interaction
NASA Astrophysics Data System (ADS)
Bauer, Dieter; Koval, Peter
2006-03-01
The QPROP package is presented. QPROP has been developed to study laser-atom interaction in the nonperturbative regime where nonlinear phenomena such as above-threshold ionization, high order harmonic generation, and dynamic stabilization are known to occur. In the nonrelativistic regime and within the single active electron approximation, these phenomena can be studied with QPROP in the most rigorous way by solving the time-dependent Schrödinger equation in three spatial dimensions. Because QPROP is optimized for the study of quantum systems that are spherically symmetric in their initial, unperturbed configuration, all wavefunctions are expanded in spherical harmonics. Time-propagation of the wavefunctions is performed using a split-operator approach. Photoelectron spectra are calculated employing a window-operator technique. Besides the solution of the time-dependent Schrödinger equation in single active electron approximation, QPROP allows to study many-electron systems via the solution of the time-dependent Kohn-Sham equations. Program summaryProgram title:QPROP Catalogue number:ADXB Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADXB Program obtainable from:CPC Program Library, Queen's University of Belfast, N. Ireland Computer on which program has been tested:PC Pentium IV, Athlon Operating system:Linux Program language used:C++ Memory required to execute with typical data:Memory requirements depend on the number of propagated orbitals and on the size of the orbitals. For instance, time-propagation of a hydrogenic wavefunction in the perturbative regime requires about 64 KB RAM (4 radial orbitals with 1000 grid points). Propagation in the strongly nonperturbative regime providing energy spectra up to high energies may need 60 radial orbitals, each with 30000 grid points, i.e. about 30 MB. Examples are given in the article. No. of bits in a word:Real and complex valued numbers of double precision are used No. of lines in distributed program, including test data, etc.:69 995 No. of bytes in distributed program, including test data, etc.: 2 927 567 Peripheral used:Disk for input-output, terminal for interaction with the user CPU time required to execute test data:Execution time depends on the size of the propagated orbitals and the number of time-steps Distribution format:tar.gz Nature of the physical problem:Atoms put into the strong field of modern lasers display a wealth of novel phenomena that are not accessible to conventional perturbation theory where the external field is considered small as compared to inneratomic forces. Hence, the full ab initio solution of the time-dependent Schrödinger equation is desirable but in full dimensionality only feasible for no more than two (active) electrons. If many-electron effects come into play or effective ground state potentials are needed, (time-dependent) density functional theory may be employed. QPROP aims at providing tools for (i) the time-propagation of the wavefunction according to the time-dependent Schrödinger equation, (ii) the time-propagation of Kohn-Sham orbitals according to the time-dependent Kohn-Sham equations, and (iii) the energy-analysis of the final one-electron wavefunction (or the Kohn-Sham orbitals). Method of solution:An expansion of the wavefunction in spherical harmonics leads to a coupled set of equations for the radial wavefunctions. These radial wavefunctions are propagated using a split-operator technique and the Crank-Nicolson approximation for the short-time propagator. The initial ground state is obtained via imaginary time-propagation for spherically symmetric (but otherwise arbitrary) effective potentials. Excited states can be obtained through the combination of imaginary time-propagation and orthogonalization. For the Kohn-Sham scheme a multipole expansion of the effective potential is employed. Wavefunctions can be analyzed using the window-operator technique, facilitating the calculation of electron spectra, either angular-resolved or integrated Restrictions onto the complexity of the problem:The coupling of the atom to the external field is treated in dipole approximation. The time-dependent Schrödinger solver is restricted to the treatment of a single active electron. As concerns the time-dependent density functional mode of QPROP, the Hartree-potential (accounting for the classical electron-electron repulsion) is expanded up to the quadrupole. Only the monopole term of the Krieger-Li-Iafrate exchange potential is currently implemented. As in any nontrivial optimization problem, convergence to the optimal many-electron state (i.e. the ground state) is not automatically guaranteed External routines/libraries used:The program uses the well established libraries BLAS, LAPACK, and F2C
Calibrated Noise Measurements with Induced Receiver Gain Fluctuations
NASA Technical Reports Server (NTRS)
Racette, Paul; Walker, David; Gu, Dazhen; Rajola, Marco; Spevacek, Ashly
2011-01-01
The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.
Determining slack tide with a GPS receiver on an anchored buoy
NASA Astrophysics Data System (ADS)
Valk, M.; Savenije, H. H. G.; Tiberius, C. C. J. M.; Luxemburg, W. M. J.
2014-07-01
In this paper we present a novel method to determine the time of occurrence of tidal slack with a GPS receiver mounted on an anchored buoy commonly used to delineate shipping lanes in estuaries and tidal channels. Slack tide occurs when the tide changes direction from ebb to flood flow or from flood to ebb. The determination of this point in time is not only useful for shipping and salvaging, it is also important information for calibrating tidal models, for determining the maximum salt intrusion and for the further refinement of the theory on tidal propagation. The accuracy of the timing is well within 10 min and the method - able to operate in real time - is relatively cheap and easy to implement on a permanent basis or in short field campaigns.
Determining slack tide with a GPS receiver on an anchored buoy
NASA Astrophysics Data System (ADS)
Valk, M.; Savenije, H. H. G.; Tiberius, C. C. J. M.; Luxemburg, W. M. J.
2013-11-01
In this paper we present a novel method to determine the time of occurrence of tidal slack with a GPS receiver mounted on an anchored buoy commonly used to delineate shipping lanes in estuaries and tidal channels. Slack tide occurs when the tide changes direction from ebb to flood flow, or from flood to ebb. The determination of this point in time is not only useful for shipping and salvaging, it is also important information for calibrating tidal models, for determining the maximum salt intrusion and for the further refinement of the theory on tidal propagation. The accuracy of the timing is well within 10 min and the method - able to operate in real-time - is relatively cheap and easy to implement on a permanent basis or in short field campaigns.
2011-01-12
including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and...Contractor Sales Data 46 Recommendations, Management Comments, and Our Response 47 Appendices A. Scope and Methodology B. Prior Audit Coverage C. DRMO...the receiving offtcial verifies the item ’s condition and ensures the quantities of items received match the DTID data . If the DTID data is
Operating system for a real-time multiprocessor propulsion system simulator
NASA Technical Reports Server (NTRS)
Cole, G. L.
1984-01-01
The success of the Real Time Multiprocessor Operating System (RTMPOS) in the development and evaluation of experimental hardware and software systems for real time interactive simulation of air breathing propulsion systems was evaluated. The Real Time Multiprocessor Operating System (RTMPOS) provides the user with a versatile, interactive means for loading, running, debugging and obtaining results from a multiprocessor based simulator. A front end processor (FEP) serves as the simulator controller and interface between the user and the simulator. These functions are facilitated by the RTMPOS which resides on the FEP. The RTMPOS acts in conjunction with the FEP's manufacturer supplied disk operating system that provides typical utilities like an assembler, linkage editor, text editor, file handling services, etc. Once a simulation is formulated, the RTMPOS provides for engineering level, run time operations such as loading, modifying and specifying computation flow of programs, simulator mode control, data handling and run time monitoring. Run time monitoring is a powerful feature of RTMPOS that allows the user to record all actions taken during a simulation session and to receive advisories from the simulator via the FEP. The RTMPOS is programmed mainly in PASCAL along with some assembly language routines. The RTMPOS software is easily modified to be applicable to hardware from different manufacturers.
2016-12-22
in both the energy received and the travel time , both exhibiting strong 3D propagation. A paper was published on using noise correlations to estimate...3-5 Hz. 3.2. Passive Acoustic Thermometry From theoretical considerations it follows that the acoustic travel time between two sensors can be...obtained from the ambient noise field. In underwater acoustics, this travel time strongly depends on the depth and temperature and to a lesser extent
Four-channel temperature and humidity microwave scanning radiometer
NASA Astrophysics Data System (ADS)
Xu, Pei-Yuan
1994-06-01
A compact four-channel microwave scanning radiometer for tropospheric remote sensing is being developed. A pair of 53.85 and 56.02 GHz and a pair of 23.87 and 31.65 GHz are adopted as temperature and humidity channels' frequencies respectively. For each pair of frequencies it has an offset reflector antenna and a Dicke-switching receiver. The pair of receivers is assembled in an enclosure, which is mounted on the rotating table of an azimuth mounting and the pair of antennas is connected with the rotating table of an azimuth mounting in the opposite side by a pair of elevation arms. Each antenna is composed of a 90 degree off-set paraboloid and a conical corrugated horn. Each antenna patterrn of four channels has nearly same HPBW, low side lobes, and low VSWR. The dual band humidity receiver is a time sharing type with 0.2K sensitivity at 1-sec integration time. The dual band temperature receiver is a band sharing type with 0.2K sensitivity at 10-sec integration time. The radiometer and observation are controlled by a single chip microcomputer to realize the unattended operation.
Missed deadline notification in best-effort schedulers
NASA Astrophysics Data System (ADS)
Banachowski, Scott A.; Wu, Joel; Brandt, Scott A.
2003-12-01
It is common to run multimedia and other periodic, soft real-time applications on general-purpose computer systems. These systems use best-effort scheduling algorithms that cannot guarantee applications will receive responsive scheduling to meet deadline or timing requirements. We present a simple mechanism called Missed Deadline Notification (MDN) that allows applications to notify the system when they do not receive their desired level of responsiveness. Consisting of a single system call with no arguments, this simple interface allows the operating system to provide better support for soft real-time applications without any a priori information about their timing or resource needs. We implemented MDN in three different schedulers: Linux, BEST, and BeRate. We describe these implementations and their performance when running real-time applications and discuss policies to prevent applications from abusing MDN to gain extra resources.
Can a Resident's Publication Record Predict Fellowship Publications?
Prasad, Vinay; Rho, Jason; Selvaraj, Senthil; Cheung, Mike; Vandross, Andrae; Ho, Nancy
2014-01-01
Background Internal medicine fellowship programs have an incentive to select fellows who will ultimately publish. Whether an applicant's publication record predicts long term publishing remains unknown. Methods Using records of fellowship bound internal medicine residents, we analyzed whether publications at time of fellowship application predict publications more than 3 years (2 years into fellowship) and up to 7 years after fellowship match. We calculate the sensitivity, specificity, positive and negative predictive values and likelihood ratios for every cutoff number of application publications, and plot a receiver operator characteristic curve of this test. Results Of 307 fellowship bound residents, 126 (41%) published at least one article 3 to 7 years after matching, and 181 (59%) of residents do not publish in this time period. The area under the receiver operator characteristic curve is 0.59. No cutoff value for application publications possessed adequate test characteristics. Conclusion The number of publications an applicant has at time of fellowship application is a poor predictor of who publishes in the long term. These findings do not validate the practice of using application publications as a tool for selecting fellows. PMID:24658088
Can a resident's publication record predict fellowship publications?
Prasad, Vinay; Rho, Jason; Selvaraj, Senthil; Cheung, Mike; Vandross, Andrae; Ho, Nancy
2014-01-01
Internal medicine fellowship programs have an incentive to select fellows who will ultimately publish. Whether an applicant's publication record predicts long term publishing remains unknown. Using records of fellowship bound internal medicine residents, we analyzed whether publications at time of fellowship application predict publications more than 3 years (2 years into fellowship) and up to 7 years after fellowship match. We calculate the sensitivity, specificity, positive and negative predictive values and likelihood ratios for every cutoff number of application publications, and plot a receiver operator characteristic curve of this test. Of 307 fellowship bound residents, 126 (41%) published at least one article 3 to 7 years after matching, and 181 (59%) of residents do not publish in this time period. The area under the receiver operator characteristic curve is 0.59. No cutoff value for application publications possessed adequate test characteristics. The number of publications an applicant has at time of fellowship application is a poor predictor of who publishes in the long term. These findings do not validate the practice of using application publications as a tool for selecting fellows.
Long-term energy capture and the effects of optimizing wind turbine operating strategies
NASA Technical Reports Server (NTRS)
Miller, A. H.; Formica, W. J.
1982-01-01
Methods of increasing energy capture without affecting the turbine design were investigated. The emphasis was on optimizing the wind turbine operating strategy. The operating strategy embodies the startup and shutdown algorithm as well as the algorithm for determining when to yaw (rotate) the axis of the turbine more directly into the wind. Using data collected at a number of sites, the time-dependent simulation of a MOD-2 wind turbine using various, site-dependent operating strategies provided evidence that site-specific fine tuning can produce significant increases in long-term energy capture as well as reduce the number of start-stop cycles and yawing maneuvers, which may result in reduced fatigue and subsequent maintenance.
Circadian Clocks for All Meal-Times: Anticipation of 2 Daily Meals in Rats
Mistlberger, Ralph E.; Kent, Brianne A.; Chan, Sofina; Patton, Danica F.; Weinberg, Alexander; Parfyonov, Maksim
2012-01-01
Anticipation of a daily meal in rats has been conceptualized as a rest-activity rhythm driven by a food-entrained circadian oscillator separate from the pacemaker generating light-dark (LD) entrained rhythms. Rats can also anticipate two daily mealtimes, but whether this involves independently entrained oscillators, one ‘continuously consulted’ clock, cue-dependent non-circadian interval timing or a combination of processes, is unclear. Rats received two daily meals, beginning 3-h (meal 1) and 13-h (meal 2) after lights-on (LD 14∶10). Anticipatory wheel running began 68±8 min prior to meal 1 and 101±9 min prior to meal 2 but neither the duration nor the variability of anticipation bout lengths exhibited the scalar property, a hallmark of interval timing. Meal omission tests in LD and constant dark (DD) did not alter the timing of either bout of anticipation, and anticipation of meal 2 was not altered by a 3-h advance of meal 1. Food anticipatory running in this 2-meal protocol thus does not exhibit properties of interval timing despite the availability of external time cues in LD. Across all days, the two bouts of anticipation were uncorrelated, a result more consistent with two independently entrained oscillators than a single consulted clock. Similar results were obtained for meals scheduled 3-h and 10-h after lights-on, and for a food-bin measure of anticipation. Most rats that showed weak or no anticipation to one or both meals exhibited elevated activity at mealtime during 1 or 2 day food deprivation tests in DD, suggesting covert operation of circadian timing in the absence of anticipatory behavior. A control experiment confirmed that daytime feeding did not shift LD-entrained rhythms, ruling out displaced nocturnal activity as an explanation for daytime activity. The results favor a multiple oscillator basis for 2-meal anticipatory rhythms and provide no evidence for involvement of cue-dependent interval timing. PMID:22355393
Time-Dependent Computed Tomographic Perfusion Thresholds for Patients With Acute Ischemic Stroke.
d'Esterre, Christopher D; Boesen, Mari E; Ahn, Seong Hwan; Pordeli, Pooneh; Najm, Mohamed; Minhas, Priyanka; Davari, Paniz; Fainardi, Enrico; Rubiera, Marta; Khaw, Alexander V; Zini, Andrea; Frayne, Richard; Hill, Michael D; Demchuk, Andrew M; Sajobi, Tolulope T; Forkert, Nils D; Goyal, Mayank; Lee, Ting Y; Menon, Bijoy K
2015-12-01
Among patients with acute ischemic stroke, we determine computed tomographic perfusion (CTP) thresholds associated with follow-up infarction at different stroke onset-to-CTP and CTP-to-reperfusion times. Acute ischemic stroke patients with occlusion on computed tomographic angiography were acutely imaged with CTP. Noncontrast computed tomography and magnectic resonance diffusion-weighted imaging between 24 and 48 hours were used to delineate follow-up infarction. Reperfusion was assessed on conventional angiogram or 4-hour repeat computed tomographic angiography. Tmax, cerebral blood flow, and cerebral blood volume derived from delay-insensitive CTP postprocessing were analyzed using receiver-operator characteristic curves to derive optimal thresholds for combined patient data (pooled analysis) and individual patients (patient-level analysis) based on time from stroke onset-to-CTP and CTP-to-reperfusion. One-way ANOVA and locally weighted scatterplot smoothing regression was used to test whether the derived optimal CTP thresholds were different by time. One hundred and thirty-two patients were included. Tmax thresholds of >16.2 and >15.8 s and absolute cerebral blood flow thresholds of <8.9 and <7.4 mL·min(-1)·100 g(-1) were associated with infarct if reperfused <90 min from CTP with onset <180 min. The discriminative ability of cerebral blood volume was modest. No statistically significant relationship was noted between stroke onset-to-CTP time and the optimal CTP thresholds for all parameters based on discrete or continuous time analysis (P>0.05). A statistically significant relationship existed between CTP-to-reperfusion time and the optimal thresholds for cerebral blood flow (P<0.001; r=0.59 and 0.77 for gray and white matter, respectively) and Tmax (P<0.001; r=-0.68 and -0.60 for gray and white matter, respectively) parameters. Optimal CTP thresholds associated with follow-up infarction depend on time from imaging to reperfusion. © 2015 American Heart Association, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Wenning N.; Sun, Xin; Khaleel, Mohammad A.
We study the temperature dependent Young’s modulus for the glass/ceramic seal material used in Solid Oxide Fuel Cells (SOFCs). With longer heat treatment or aging time during operation, further devitrification may reduce the residual glass content in the seal material while boosting the ceramic crystalline content. In the meantime, micro-voids induced by the cooling process from the high operating temperature to room temperature can potentially degrade the mechanical properties of the glass/ceramic sealant. Upon reheating to the SOFC operating temperature, possible self-healing phenomenon may occur in the glass/ceramic sealant which can potentially restore some of its mechanical properties. A phenomenologicalmore » model is developed to model the temperature dependent Young’s modulus of glass/ceramic seal considering the combined effects of aging, micro-voids, and possible self-healing. An aging-time-dependent crystalline content model is first developed to describe the increase of the crystalline content due to the continuing devitrification under high operating temperature. A continuum damage mechanics (CDM) model is then adapted to model the effects of both cooling induced micro-voids and reheating induced self-healing. This model is applied to model the glass-ceramic G18, a candidate SOFC seal material previously developed at PNNL. Experimentally determined temperature dependent Young’s modulus is used to validate the model predictions« less