Chung, Yun Won; Hwang, Ho Young
2010-01-01
In sensor network, energy conservation is one of the most critical issues since sensor nodes should perform a sensing task for a long time (e.g., lasting a few years) but the battery of them cannot be replaced in most practical situations. For this purpose, numerous energy conservation schemes have been proposed and duty cycling scheme is considered the most suitable power conservation technique, where sensor nodes alternate between states having different levels of power consumption. In order to analyze the energy consumption of energy conservation scheme based on duty cycling, it is essential to obtain the probability of each state. In this paper, we analytically derive steady state probability of sensor node states, i.e., sleep, listen, and active states, based on traffic characteristics and timer values, i.e., sleep timer, listen timer, and active timer. The effect of traffic characteristics and timer values on the steady state probability and energy consumption is analyzed in detail. Our work can provide sensor network operators guideline for selecting appropriate timer values for efficient energy conservation. The analytical methodology developed in this paper can be extended to other energy conservation schemes based on duty cycling with different sensor node states, without much difficulty. PMID:22219676
Experimental setups for FEL-based four-wave mixing experiments at FERMI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bencivenga, Filippo; Zangrando, Marco; Svetina, Cristian
2016-01-01
The recent advent of free-electron laser (FEL) sources is driving the scientific community to extend table-top laser research to shorter wavelengths adding elemental selectivity and chemical state specificity. Both a compact setup (mini-TIMER) and a separate instrument (EIS-TIMER) dedicated to four-wave-mixing (FWM) experiments has been designed and constructed, to be operated as a branch of the Elastic and Inelastic Scattering beamline: EIS. The FWM experiments that are planned at EIS-TIMER are based on the transient grating approach, where two crossed FEL pulses create a controlled modulation of the sample excitations while a third time-delayed pulse is used to monitor themore » dynamics of the excited state. This manuscript describes such experimental facilities, showing the preliminary results of the commissioning of the EIS-TIMER beamline, and discusses original experimental strategies being developed to study the dynamics of matter at the fs–nm time–length scales. In the near future such experimental tools will allow more sophisticated FEL-based FWM applications, that also include the use of multiple and multi-color FEL pulses.« less
Experimental setups for FEL-based four-wave mixing experiments at FERMI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bencivenga, Filippo; Zangrando, Marco; Svetina, Cristian
The recent advent of free-electron laser (FEL) sources is driving the scientific community to extend table-top laser research to shorter wavelengths adding elemental selectivity and chemical state specificity. Both a compact setup (mini-TIMER) and a separate instrument (EIS-TIMER) dedicated to four-wave-mixing (FWM) experiments has been designed and constructed, to be operated as a branch of the Elastic and Inelastic Scattering beamline: EIS. The FWM experiments that are planned at EIS-TIMER are based on the transient grating approach, where two crossed FEL pulses create a controlled modulation of the sample excitations while a third time-delayed pulse is used to monitor themore » dynamics of the excited state. This manuscript describes such experimental facilities, showing the preliminary results of the commissioning of the EIS-TIMER beamline, and discusses original experimental strategies being developed to study the dynamics of matter at the fs–nm time–length scales. In the near future such experimental tools will allow more sophisticated FEL-based FWM applications, that also include the use of multiple and multi-color FEL pulses.« less
Submillimeter Schottky Diodes with Electron Beam Lithography.
1979-12-01
Timer 2: external clock, oneshot , 0’ sixteen bit counting modes are .,selected, no data is entered; interrupts are disabled. Timer 3: external clock and...CLOCK, ONESHOT MODE, NO INTERRUPTS, 00031* 16 BIT COUNTING MODE, OUTPUT IS EN- 00032 * ABLED; NO DATA IS ENTERED, 00033 00034 * TIMER3: EXT CLOCK
Effects of digital countdown timer on intersection safety and efficiency: A systematic review.
Fu, Chuanyun; Zhang, Yaping; Qi, Weiwei; Cheng, Shaowu
2016-01-01
To investigate the available evidence referring to the effectiveness of digital countdown timers (DCTs) in improving the safety and operational efficiency of signalized intersection. A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) statement guidelines. Relevant literature was searched from electronic databases using key terms. Based on study selection and methodological quality assessment, 14 studies were included in the review. Findings of the studies were synthesized in a narrative analysis. Three types of DCT had different effects on intersection safety and operational efficiency. Green signal countdown timers (GSCTs) reduced red light violations, type I dilemma zone distributions, and rear-end collision likelihood but increased crossing after yellow onset and had mixed impacts on type II dilemma zone distributions and intersection capacity. In contrast, red signal countdown timers (RSCTs) increased intersection capacity, although their effectiveness in reducing red light violations dissipated over time. Likewise, continuous countdown timers (CCTs) significantly enhanced intersection capacity but had mixed influences on red light violations and crossing after yellow onset. Due to the limited and inconsistent evidence regarding DCTs' effects on intersection safety and efficiency, it is not sufficient to recommend any type of DCT to be installed at signalized intersections to improve safety and operational efficiency. Nevertheless, it is apparent that both RSCTs and CCTs enhance intersection capacity, though their impacts on intersection safety are unclear. Future studies need to further verify those anticipated safe and operational benefits of DCTs with enriched field observation data.
Simulation evaluation of TIMER, a time-based, terminal air traffic, flow-management concept
NASA Technical Reports Server (NTRS)
Credeur, Leonard; Capron, William R.
1989-01-01
A description of a time-based, extended terminal area ATC concept called Traffic Intelligence for the Management of Efficient Runway scheduling (TIMER) and the results of a fast-time evaluation are presented. The TIMER concept is intended to bridge the gap between today's ATC system and a future automated time-based ATC system. The TIMER concept integrates en route metering, fuel-efficient cruise and profile descents, terminal time-based sequencing and spacing together with computer-generated controller aids, to improve delivery precision for fuller use of runway capacity. Simulation results identify and show the effects and interactions of such key variables as horizon of control location, delivery time error at both the metering fix and runway threshold, aircraft separation requirements, delay discounting, wind, aircraft heading and speed errors, and knowledge of final approach speed.
Methods for synchronizing a countdown routine of a timer key and electronic device
Condit, Reston A.; Daniels, Michael A.; Clemens, Gregory P.; Tomberlin, Eric S.; Johnson, Joel A.
2015-06-02
A timer key relating to monitoring a countdown time of a countdown routine of an electronic device is disclosed. The timer key comprises a processor configured to respond to a countdown time associated with operation of the electronic device, a display operably coupled with the processor, and a housing configured to house at least the processor. The housing has an associated structure configured to engage with the electronic device to share the countdown time between the electronic device and the timer key. The processor is configured to begin a countdown routine based at least in part on the countdown time, wherein the countdown routine is at least substantially synchronized with a countdown routine of the electronic device when the timer key is removed from the electronic device. A system and method for synchronizing countdown routines of a timer key and an electronic device are also disclosed.
Apparatus, system, and method for synchronizing a timer key
Condit, Reston A; Daniels, Michael A; Clemens, Gregory P; Tomberlin, Eric S; Johnson, Joel A
2014-04-22
A timer key relating to monitoring a countdown time of a countdown routine of an electronic device is disclosed. The timer key comprises a processor configured to respond to a countdown time associated with operation of the electronic device, a display operably coupled with the processor, and a housing configured to house at least the processor. The housing has an associated structure configured to engage with the electronic device to share the countdown time between the electronic device and the timer key. The processor is configured to begin a countdown routine based at least in part on the countdown time, wherein the countdown routine is at least substantially synchronized with a countdown routine of the electronic device when the timer key is removed from the electronic device. A system and method for synchronizing countdown routines of a timer key and an electronic device are also disclosed.
Precise Interval Timer for Software Defined Radio
NASA Technical Reports Server (NTRS)
Pozhidaev, Aleksey (Inventor)
2014-01-01
A precise digital fractional interval timer for software defined radios which vary their waveform on a packet-by-packet basis. The timer allows for variable length in the preamble of the RF packet and allows to adjust boundaries of the TDMA (Time Division Multiple Access) Slots of the receiver of an SDR based on the reception of the RF packet of interest.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-19
... ``sleep timer'') and then reactivate the re-COA feature.\\7\\ All timers will be reset if a new complex.... Assume the sleep timer is set at 60 minutes. Assume the current market calculated based on the derived... the resting order has been subject to COA 2 times since it was booked in COB, the 60 minute sleep...
Simple Interval Timers for Microcomputers.
ERIC Educational Resources Information Center
McInerney, M.; Burgess, G.
1985-01-01
Discusses simple interval timers for microcomputers, including (1) the Jiffy clock; (2) CPU count timers; (3) screen count timers; (4) light pen timers; and (5) chip timers. Also examines some of the general characteristics of all types of timers. (JN)
Kang, Junsu; Lee, Donghyeon; Heo, Young Jin; Chung, Wan Kyun
2017-11-07
For highly-integrated microfluidic systems, an actuation system is necessary to control the flow; however, the bulk of actuation devices including pumps or valves has impeded the broad application of integrated microfluidic systems. Here, we suggest a microfluidic process control method based on built-in microfluidic circuits. The circuit is composed of a fluidic timer circuit and a pneumatic logic circuit. The fluidic timer circuit is a serial connection of modularized timer units, which sequentially pass high pressure to the pneumatic logic circuit. The pneumatic logic circuit is a NOR gate array designed to control the liquid-controlling process. By using the timer circuit as a built-in signal generator, multi-step processes could be done totally inside the microchip without any external controller. The timer circuit uses only two valves per unit, and the number of process steps can be extended without limitation by adding timer units. As a demonstration, an automation chip has been designed for a six-step droplet treatment, which entails 1) loading, 2) separation, 3) reagent injection, 4) incubation, 5) clearing and 6) unloading. Each process was successfully performed for a pre-defined step-time without any external control device.
Micro-controller based air pressure monitoring instrumentation system using optical fibers as sensor
NASA Astrophysics Data System (ADS)
Hazarika, D.; Pegu, D. S.
2013-03-01
This paper describes a micro-controller based instrumentation system to monitor air pressure using optical fiber sensors. The principle of macrobending is used to develop the sensor system. The instrumentation system consists of a laser source, a beam splitter, two multi mode optical fibers, two Light Dependent Resistance (LDR) based timer circuits and a AT89S8252 micro-controller. The beam splitter is used to divide the laser beam into two parts and then these two beams are launched into two multi mode fibers. One of the multi mode fibers is used as the sensor fiber and the other one is used as the reference fiber. The use of the reference fiber is to eliminate the environmental effects while measuring the air pressure magnitude. The laser beams from the sensor and reference fibers are applied to two identical LDR based timer circuits. The LDR based timer circuits are interfaced to a micro-controller through its counter pins. The micro-controller samples the frequencies of the timer circuits using its counter-0 and counter-1 and the counter values are then processed to provide the measure of air pressure magnitude.
A Temperature Sensor using a Silicon-on-Insulator (SOI) Timer for Very Wide Temperature Measurement
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Hammoud, Ahmad; Elbuluk, Malik; Culley, Dennis E.
2008-01-01
A temperature sensor based on a commercial-off-the-shelf (COTS) Silicon-on-Insulator (SOI) Timer was designed for extreme temperature applications. The sensor can operate under a wide temperature range from hot jet engine compartments to cryogenic space exploration missions. For example, in Jet Engine Distributed Control Architecture, the sensor must be able to operate at temperatures exceeding 150 C. For space missions, extremely low cryogenic temperatures need to be measured. The output of the sensor, which consisted of a stream of digitized pulses whose period was proportional to the sensed temperature, can be interfaced with a controller or a computer. The data acquisition system would then give a direct readout of the temperature through the use of a look-up table, a built-in algorithm, or a mathematical model. Because of the wide range of temperature measurement and because the sensor is made of carefully selected COTS parts, this work is directly applicable to the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program--Jet Engine Distributed Engine Control Task and to the NASA Electronic Parts and Packaging (NEPP) Program. In the past, a temperature sensor was designed and built using an SOI operational amplifier, and a report was issued. This work used an SOI 555 timer as its core and is completely new work.
Networked Workstations and Parallel Processing Utilizing Functional Languages
1993-03-01
program . This frees the programmer to concentrate on what the program is to do, not how the program is...traditional ’von Neumann’ architecture uses a timer based (e.g., the program counter), sequentially pro- grammed, single processor approach to problem...traditional ’von Neumann’ architecture uses a timer based (e.g., the program counter), sequentially programmed , single processor approach to
ERIC Educational Resources Information Center
Adhitama, Egy; Fauzi, Ahmad
2018-01-01
In this study, a pendulum experimental tool with a light-based timer has been developed to measure the period of a simple pendulum. The obtained data was automatically recorded in an Excel spreadsheet. The intensity of monochromatic light, sensed by a 3DU5C phototransistor, dynamically changes as the pendulum swings. The changed intensity varies…
Achieving High Resolution Timer Events in Virtualized Environment.
Adamczyk, Blazej; Chydzinski, Andrzej
2015-01-01
Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events.
Does It Work? 555-Timer Checker Leaves No Doubt
ERIC Educational Resources Information Center
Harman, Charles
2009-01-01
This article details the construction and use of the 555-timer checker. The 555-timer checker allows the user to dynamically check a 555-timer, an integrated circuit device. Of its many applications, it provides timing applications that unijunction transistors once performed. (Contains 4 figures and 3 photos.)
Hardware support for software controlled fast reconfiguration of performance counters
Salapura, Valentina; Wisniewski, Robert W.
2013-06-18
Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.
Hardware support for software controlled fast reconfiguration of performance counters
Salapura, Valentina; Wisniewski, Robert W
2013-09-24
Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.
Achieving High Resolution Timer Events in Virtualized Environment
Adamczyk, Blazej; Chydzinski, Andrzej
2015-01-01
Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs—Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events. PMID:26177366
NASA Technical Reports Server (NTRS)
Hall, William A.; Gilbert, John
1990-01-01
Electronic metronome paces users through wide range of exercise routines. Conceptual programmable cadence timer provides rhythmic aural and visual cues. Timer automatically changes cadence according to program entered by the user. It also functions as clock, stopwatch, or alarm. Modular pacer operated as single unit or as two units. With audiovisual module moved away from base module, user concentrates on exercise cues without distraction from information appearing on the liquid-crystal display. Variety of uses in rehabilitative medicine, experimental medicine, sports, and gymnastics. Used in intermittent positive-pressure breathing treatment, in which patient must rhythmically inhale and retain medication delivered under positive pressure; and in incentive spirometer treatment, in which patient must inhale maximally at regular intervals.
Effects of countdown timers on driver behavior after the yellow onset at Chinese intersections.
Long, Kejun; Han, Lee D; Yang, Qiang
2011-10-01
Few studies have focused on the effect of countdown timers at signalized intersections in China, where such timers are widely deployed for their perceived benefits of increased safety and capacity. This study examines the effect of countdown timers on driver behavior during the yellow interval. Signal phasing and traffic operations were videotaped at 4 comparable signalized intersections under normal conditions. Microscopic details were extracted manually at 25 Hz to yield 24 h of data on onset time of the yellow, onset time of the red, driver location and actions after the onset of the yellow, red light-running violations, etc. For comparable intersections with and without countdown timers, driver behavior measured by driver decision (stop or go) and vehicle entry time (when the vehicle crosses the stop line) were analyzed using binary logistical regression (BLR) and a nonparametric test, respectively. The results suggest that countdown timers can indeed influence driver behaviors, in terms of decisions to stop or cross the intersection as well as the distribution of vehicle entry times. There was a strong correlation between the presence of countdown timers and an increase in red light violations. Countdown timers may lead to increased entrance into the intersection during the later portions of the yellow and even the red. This alarming finding calls for further research as well as for serious consideration before the field deployment of countdown timers.
Evaluation of Plastic Media Blasting Equipment
1987-04-01
the differential pressure across the filter element or by a timer with a differential pressure switch override. The timer and the differential pressure ...automatic. The mechanism should be activated by the differential pressure across the filter element or by a timer with a differential pressure switch override...The timer and the differential pressure switch settings should be adjustable. The dust then falls to the bottom of the baghouse for
Complex contagions with timers
NASA Astrophysics Data System (ADS)
Oh, Se-Wook; Porter, Mason A.
2018-03-01
There has been a great deal of effort to try to model social influence—including the spread of behavior, norms, and ideas—on networks. Most models of social influence tend to assume that individuals react to changes in the states of their neighbors without any time delay, but this is often not true in social contexts, where (for various reasons) different agents can have different response times. To examine such situations, we introduce the idea of a timer into threshold models of social influence. The presence of timers on nodes delays adoptions—i.e., changes of state—by the agents, which in turn delays the adoptions of their neighbors. With a homogeneously-distributed timer, in which all nodes have the same amount of delay, the adoption order of nodes remains the same. However, heterogeneously-distributed timers can change the adoption order of nodes and hence the "adoption paths" through which state changes spread in a network. Using a threshold model of social contagions, we illustrate that heterogeneous timers can either accelerate or decelerate the spread of adoptions compared to an analogous situation with homogeneous timers, and we investigate the relationship of such acceleration or deceleration with respect to the timer distribution and network structure. We derive an analytical approximation for the temporal evolution of the fraction of adopters by modifying a pair approximation for the Watts threshold model, and we find good agreement with numerical simulations. We also examine our new timer model on networks constructed from empirical data.
The provision of stove timers to individuals with cognitive impairment.
Nygård, Louise; Starkhammar, Sofia; Lilja, Margareta
2008-03-01
The aim of this study was to identify the characteristics of persons who were provided with timing devices on stoves, and to investigate the application procedure and recommendations for timer options. The case files at an Agency for Home Modifications in an urban community in Sweden during 2002 (n = 945) were audited. The sample was divided into two groups: those diagnosed or suspected of dementia or age-related memory deficits (n = 788), and those with other diagnoses (n = 151). Overall, the applicants for stove timers were elderly females, living alone. Assistance with the application forms by health professionals was common in both groups. However, the options available for tailoring the use of the device were not used consistently and the opportunity for professional follow-up appeared limited. The device seemed to be used as a safety precaution rather than as a device to support independent activity performance based on individual users' needs. The results indicate that improvements in the implementation and provision of stove timers could be achieved through education and collaboration between different stakeholders.
New Concept Firefighting Agent Delivery System
1992-05-01
timer circuit . The time to rupture could be determined by the interactive computer associated with the kazincher system based on range-to-target and...windage effects. The timer circuit considered was a simple resistance capacitance (RC) timing network wi:h a set rate of discharge. The capacito, would...circut -to the canister timing circuit would be separated at launch and could initir.te the timing sequence. A "g" switch could aiso be used to
NASA Astrophysics Data System (ADS)
Eliazar, Iddo
2017-12-01
Search processes play key roles in various scientific fields. A widespread and effective search-process scheme, which we term Restart Search, is based on the following restart algorithm: i) set a timer and initiate a search task; ii) if the task was completed before the timer expired, then stop; iii) if the timer expired before the task was completed, then go back to the first step and restart the search process anew. In this paper a branching feature is added to the restart algorithm: at every transition from the algorithm's third step to its first step branching takes place, thus multiplying the search effort. This branching feature yields a search-process scheme which we term Branching Search. The running time of Branching Search is analyzed, closed-form results are established, and these results are compared to the coresponding running-time results of Restart Search.
DOT National Transportation Integrated Search
2011-12-01
Pedestrian countdown timers are becoming common at urban and suburban intersections. The added information that : pedestrian countdown timers provide to pedestrians can also be used by approaching drivers. A before-and-after case study : on the effec...
Breen, Michael; Nogales, Aitor; Baker, Steven F; Perez, Daniel R; Martínez-Sobrido, Luis
2016-01-01
Influenza A and B viruses (IAV and IBV, respectively) cause annual seasonal human respiratory disease epidemics. In addition, IAVs have been implicated in occasional pandemics with inordinate health and economic consequences. Studying influenza viruses in vitro or in vivo requires the use of laborious secondary methodologies to identify infected cells. To circumvent this requirement, replication-competent infectious influenza viruses expressing an easily traceable fluorescent reporter protein can be used. Timer is a fluorescent protein that undergoes a time-dependent color emission conversion from green to red. The rate of spectral change is independent of Timer protein concentration and can be used to chronologically measure the duration of its expression. Here, we describe the generation of replication-competent IAV and IBV where the viral non-structural protein 1 (NS1) was fused to the fluorescent dynamic Timer protein. Timer-expressing IAV and IBV displayed similar plaque phenotypes and growth kinetics to wild-type viruses in tissue culture. Within infected cells, Timer's spectral shift can be used to measure the rate and cell-to-cell spread of infection using fluorescent microscopy, plate readers, or flow cytometry. The progression of Timer-expressing IAV infection was also evaluated in a mouse model, demonstrating the feasibility to characterize IAV cell-to-cell infections in vivo. By providing the ability to chronologically track viral spread, Timer-expressing influenza viruses are an excellent option to evaluate the in vitro and in vivo dynamics of viral infection.
Professional Development and National Science Week.
ERIC Educational Resources Information Center
Jones, Alison
1999-01-01
Summarizes the events that took place at the Primary Science Seminar held by the Science Teachers' Association of Western Australia (STAWA). Features instructions for seven time-related activities taught at the seminar including Sundials, Water Clock, Sand Timer, Pendulum, Tornado Timer, Marble Timer, and A Matter of Timing. (WRM)
Strategy for Developing Expert-System-Based Internet Protocols (TCP/IP)
NASA Technical Reports Server (NTRS)
Ivancic, William D.
1997-01-01
The Satellite Networks and Architectures Branch of NASA's Lewis Research is addressing the issue of seamless interoperability of satellite networks with terrestrial networks. One of the major issues is improving reliable transmission protocols such as TCP over long latency and error-prone links. Many tuning parameters are available to enhance the performance of TCP including segment size, timers and window sizes. There are also numerous congestion avoidance algorithms such as slow start, selective retransmission and selective acknowledgment that are utilized to improve performance. This paper provides a strategy to characterize the performance of TCP relative to various parameter settings in a variety of network environments (i.e. LAN, WAN, wireless, satellite, and IP over ATM). This information can then be utilized to develop expert-system-based Internet protocols.
Object-oriented millisecond timers for the PC.
Hamm, J P
2001-11-01
Object-oriented programming provides a useful structure for designing reusable code. Accurate millisecond timing is essential for many areas of research. With this in mind, this paper provides a Turbo Pascal unit containing an object-oriented millisecond timer. This approach allows for multiple timers to be running independently. The timers may also be set at different levels of temporal precision, such as 10(-3) (milliseconds) or 10(-5) sec. The object also is able to store the time of a flagged event for later examination without interrupting the ongoing timing operation.
Polosky, Marc A.; Garcia, Ernest J.; Plummer, David W.
2001-01-01
A microminiature timer having an optical readout is disclosed. The timer can be formed by surface micromachining or LIGA processes on a silicon substrate. The timer includes an integral motor (e.g. an electrostatic motor) that can intermittently wind a mainspring to store mechanical energy for driving a train of meshed timing gears at a rate that is regulated by a verge escapement. Each timing gear contains an optical encoder that can be read out with one or more light beams (e.g. from a laser or light-emitting diode) to recover timing information. In the event that electrical power to the timer is temporarily interrupted, the mechanical clock formed by the meshed timing gears and verge escapement can continue to operate, generating accurate timing information that can be read out when the power is restored.
A microfluidic timer for timed valving and pumping in centrifugal microfluidics.
Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N
2015-03-21
Accurate timing of microfluidic operations is essential for the automation of complex laboratory workflows, in particular for the supply of sample and reagents. Here we present a new unit operation for timed valving and pumping in centrifugal microfluidics. It is based on temporary storage of pneumatic energy and time delayed sudden release of said energy. The timer is loaded at a relatively higher spinning frequency. The countdown is started by reducing to a relatively lower release frequency, at which the timer is released after a pre-defined delay time. We demonstrate timing for 1) the sequential release of 4 liquids at times of 2.7 s ± 0.2 s, 14.0 s ± 0.5 s, 43.4 s ± 1.0 s and 133.8 s ± 2.3 s, 2) timed valving of typical assay reagents (contact angles 36-78°, viscosities 0.9-5.6 mPa s) and 3) on demand valving of liquids from 4 inlet chambers in any user defined sequence controlled by the spinning protocol. The microfluidic timer is compatible to all wetting properties and viscosities of common assay reagents and does neither require assistive equipment, nor coatings. It can be monolithically integrated into a microfluidic test carrier and is compatible to scalable fabrication technologies such as thermoforming or injection molding.
Instantaneous Velocity Using Photogate Timers
ERIC Educational Resources Information Center
Wolbeck, John
2010-01-01
Photogate timers are commonly used in physics laboratories to determine the velocity of a passing object. In this application a card attached to a moving object breaks the beam of the photogate timer providing the time for the card to pass. The length L of the passing card can then be divided by this time to yield the average velocity (or speed)…
Baker, Steven F.; Perez, Daniel R.; Martínez-Sobrido, Luis
2016-01-01
Influenza A and B viruses (IAV and IBV, respectively) cause annual seasonal human respiratory disease epidemics. In addition, IAVs have been implicated in occasional pandemics with inordinate health and economic consequences. Studying influenza viruses in vitro or in vivo requires the use of laborious secondary methodologies to identify infected cells. To circumvent this requirement, replication-competent infectious influenza viruses expressing an easily traceable fluorescent reporter protein can be used. Timer is a fluorescent protein that undergoes a time-dependent color emission conversion from green to red. The rate of spectral change is independent of Timer protein concentration and can be used to chronologically measure the duration of its expression. Here, we describe the generation of replication-competent IAV and IBV where the viral non-structural protein 1 (NS1) was fused to the fluorescent dynamic Timer protein. Timer-expressing IAV and IBV displayed similar plaque phenotypes and growth kinetics to wild-type viruses in tissue culture. Within infected cells, Timer’s spectral shift can be used to measure the rate and cell-to-cell spread of infection using fluorescent microscopy, plate readers, or flow cytometry. The progression of Timer-expressing IAV infection was also evaluated in a mouse model, demonstrating the feasibility to characterize IAV cell-to-cell infections in vivo. By providing the ability to chronologically track viral spread, Timer-expressing influenza viruses are an excellent option to evaluate the in vitro and in vivo dynamics of viral infection. PMID:26809059
NASA Astrophysics Data System (ADS)
Adhitama, Egy; Fauzi, Ahmad
2018-05-01
In this study, a pendulum experimental tool with a light-based timer has been developed to measure the period of a simple pendulum. The obtained data was automatically recorded in an Excel spreadsheet. The intensity of monochromatic light, sensed by a 3DU5C phototransistor, dynamically changes as the pendulum swings. The changed intensity varies the resistance value and was processed by the microcontroller, ATMega328, to obtain a signal period as a function of time and brightness when the pendulum crosses the light. Through the experiment, using calculated average periods, the gravitational acceleration value has been accurately and precisely determined.
Low-Cost Timer to Measure the Terminal Velocity of a Magnet Falling through a Conducting Pipe
ERIC Educational Resources Information Center
Pathare, Shirish R.; Huli, Saurabhee; Lahane, Rohan; Sawant, Sumedh
2014-01-01
Dropping a magnet into a conductive pipe (made up of copper or brass or aluminum) is a very popular demonstration in many physics classrooms and laboratories. In this paper we present an inexpensive timer that can be used to measure the terminal velocity of the magnet falling through a conducting pipe. The timer assembly consists of Hall effect…
Decentralized cooperative TOA/AOA target tracking for hierarchical wireless sensor networks.
Chen, Ying-Chih; Wen, Chih-Yu
2012-11-08
This paper proposes a distributed method for cooperative target tracking in hierarchical wireless sensor networks. The concept of leader-based information processing is conducted to achieve object positioning, considering a cluster-based network topology. Random timers and local information are applied to adaptively select a sub-cluster for the localization task. The proposed energy-efficient tracking algorithm allows each sub-cluster member to locally estimate the target position with a Bayesian filtering framework and a neural networking model, and further performs estimation fusion in the leader node with the covariance intersection algorithm. This paper evaluates the merits and trade-offs of the protocol design towards developing more efficient and practical algorithms for object position estimation.
Improved Timing Scheme for Spaceborne Precipitation Radar
NASA Technical Reports Server (NTRS)
Berkun, Andrew; Fischman, Mark
2004-01-01
An improved timing scheme has been conceived for operation of a scanning satellite-borne rain-measuring radar system. The scheme allows a real-time-generated solution, which is required for auto targeting. The current timing scheme used in radar satellites involves pre-computing a solution that allows the instrument to catch all transmitted pulses without transmitting and receiving at the same time. Satellite altitude requires many pulses in flight at any time, and the timing solution to prevent transmit and receive operations from colliding is usually found iteratively. The proposed satellite has a large number of scanning beams each with a different range to target and few pulses per beam. Furthermore, the satellite will be self-targeting, so the selection of which beams are used will change from sweep to sweep. The proposed timing solution guarantees no echo collisions, can be generated using simple FPGA-based hardware in real time, and can be mathematically shown to deliver the maximum number of pulses per second, given the timing constraints. The timing solution is computed every sweep, and consists of three phases: (1) a build-up phase, (2) a feedback phase, and (3) a build-down phase. Before the build-up phase can begin, the beams to be transmitted are sorted in numerical order. The numerical order of the beams is also the order from shortest range to longest range. Sorting the list guarantees no pulse collisions. The build-up phase begins by transmitting the first pulse from the first beam on the list. Transmission of this pulse starts a delay counter, which stores the beam number and the time delay to the beginning of the receive window for that beam. The timing generator waits just long enough to complete the transmit pulse plus one receive window, then sends out the second pulse. The second pulse starts a second delay counter, which stores its beam number and time delay. This process continues until an output from the first timer indicates there is less than one transmit pulse width until the start of the next receive event. This blocks future transmit pulses in the build-up phase. The feedback phase begins with the first timer paying off and starting the first receive window. When the first receive window is complete, the timing generator transmits the next beam from the list. When the second timer pays off, the second receive event is started. Following the second receive event, the timing generator will transmit the next beam on the list and start an additional timer. The timers work in a circular buffer fashion so there only need to be enough to cover the maximum number of echoes in flight.
Bradshaw, W E; Emerson, K J; Holzapfel, C M
2012-01-01
The genetic relationship between the daily circadian clock and the seasonal photoperiodic timer remains a subject of intense controversy. In Wyeomyia smithii, the critical photoperiod (an overt expression of the photoperiodic timer) evolves independently of the rhythmic response to the Nanda–Hamner protocol (an overt expression of the daily circadian clock) over a wide geographical range in North America. Herein, we focus on these two processes within a single local population in which there is a negative genetic correlation between them. We show that antagonistic selection against this genetic correlation rapidly breaks it down and, in fact, reverses its sign, showing that the genetic correlation is due primarily to linkage and not to pleiotropy. This rapid reversal of the genetic correlation within a small, single population means that it is difficult to argue that circadian rhythmicity forms the necessary, causal basis for the adaptive divergence of photoperiodic time measurement within populations or for the evolution of photoperiodic time measurement among populations over a broad geographical gradient of seasonal selection. PMID:22072069
Apparatus for Teaching Physics
ERIC Educational Resources Information Center
Gottlieb, Herbert H., Ed.
1977-01-01
Describes physics laboratory equipment including: circuit improvements for an electronic counter-timer, a commercial counter-timer-frequency meter, and a device for demonstrating resonating air columns. (SL)
Reminder card helps patients remember OCs.
1999-11-01
Organon has developed the Reminder Card to help women patients remember their regular intake of oral contraceptive (OC) pills. About 50% of women take birth control pills as prescribed, 25% miss a pill per month, and 25% miss two or more pills in the same time frame. The plastic card, about the size and shape of a credit card, contains a microchip timer. Reminder cards are available to providers who use the Starter Kits issued by the company for new-start patients on the Mircette OC. When patients begin their first pack of pills, they select the time of day they prefer to have the Reminder Card emit its tiny beep. The time is set into the microchip timer and the card is programmed to sound automatically at the pre-set time each day for the next three months. The direction for using the Reminder Card is outlined.
Prototype Automated Equipment to Perform Poising and Beat Rate Operations on the M577 MTSQ Fuze.
1978-09-30
Regulation Machine which sets the M577 Fuze Timer beat rate and the Automatic Poising Machine which J dynamically balances the Timer balance wheel...in trouble shooting., The Automatic Poising Machine Figure 3 which inspects and corrects the dynamic I balance of the Balance Wheel Assembly was...machine is intimately related to the fastening method of the wire to the Timer at one end and the Balance Wheel at the other, a review of the history
Architecture and mechanism of the central gear in an ancient molecular timer.
Egli, Martin
2017-03-01
Molecular clocks are the product of natural selection in organisms from bacteria to human and their appearance early in evolution such as in the prokaryotic cyanobacterium Synechococcus elongatus suggests that these timers served a crucial role in genetic fitness. Thus, a clock allows cyanobacteria relying on photosynthesis and nitrogen fixation to temporally space the two processes and avoid exposure of nitrogenase carrying out fixation to high levels of oxygen produced during photosynthesis. Fascinating properties of molecular clocks are the long time constant, their precision and temperature compensation. Although these are hallmarks of all circadian oscillators, the actual cogs and gears that control clocks vary widely between organisms, indicating that circadian timers evolved convergently multiple times, owing to the selective pressure of an environment with a daily light/dark cycle. In S. elongatus , the three proteins KaiA, KaiB and KaiC in the presence of ATP constitute a so-called post-translational oscillator (PTO). The KaiABC PTO can be reconstituted in an Eppendorf tube and keeps time in a temperature-compensated manner. The ease by which the KaiABC clock can be studied in vitro has made it the best-investigated molecular clock system. Over the last decade, structures of all three Kai proteins and some of their complexes have emerged and mechanistic aspects have been analysed in considerable detail. This review focuses on the central gear of the S. elongatus clock and only enzyme among the three proteins: KaiC. Our determination of the three-dimensional structure of KaiC early in the quest for a better understanding of the inner workings of the cyanobacterial timer revealed its unusual architecture and conformational differences and unique features of the two RecA-like domains constituting KaiC. The structure also pinpointed phosphorylation sites and differential interactions with ATP molecules at subunit interfaces, and helped guide experiments to ferret out mechanistic aspects of the ATPase, auto-phosphorylation and auto-dephosphorylation reactions catalysed by the homo-hexamer. Comparisons between the structure of KaiC and those of nanomachines such as F1-ATPase and CaMKII also exposed shared architectural features (KaiC/ATPase), mechanistic principles (KaiC/CaMKII) and phenomena, such as subunit exchange between hexameric particles critical for function (clock synchronization, KaiABC; memory-storage, CaMKII). © 2017 The Author(s).
Analysis of Noise Mechanisms in Cell-Size Control.
Modi, Saurabh; Vargas-Garcia, Cesar Augusto; Ghusinga, Khem Raj; Singh, Abhyudai
2017-06-06
At the single-cell level, noise arises from multiple sources, such as inherent stochasticity of biomolecular processes, random partitioning of resources at division, and fluctuations in cellular growth rates. How these diverse noise mechanisms combine to drive variations in cell size within an isoclonal population is not well understood. Here, we investigate the contributions of different noise sources in well-known paradigms of cell-size control, such as adder (division occurs after adding a fixed size from birth), sizer (division occurs after reaching a size threshold), and timer (division occurs after a fixed time from birth). Analysis reveals that variation in cell size is most sensitive to errors in partitioning of volume among daughter cells, and not surprisingly, this process is well regulated among microbes. Moreover, depending on the dominant noise mechanism, different size-control strategies (or a combination of them) provide efficient buffering of size variations. We further explore mixer models of size control, where a timer phase precedes/follows an adder, as has been proposed in Caulobacter crescentus. Although mixing a timer and an adder can sometimes attenuate size variations, it invariably leads to higher-order moments growing unboundedly over time. This results in a power-law distribution for the cell size, with an exponent that depends inversely on the noise in the timer phase. Consistent with theory, we find evidence of power-law statistics in the tail of C. crescentus cell-size distribution, although there is a discrepancy between the observed power-law exponent and that predicted from the noise parameters. The discrepancy, however, is removed after data reveal that the size added by individual newborns in the adder phase itself exhibits power-law statistics. Taken together, this study provides key insights into the role of noise mechanisms in size homeostasis, and suggests an inextricable link between timer-based models of size control and heavy-tailed cell-size distributions. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Kezar, Adrianna; Maxey, Daniel
2012-01-01
It is important to understand existing research on the connections between non-tenure-track faculty and student learning and to continue to research these issues. Although working conditions vary across the academy and even within a single institution, many faculty--particularly part-timers--are not permitted to contribute to curriculum planning…
Novel multipurpose timer for laboratories
NASA Technical Reports Server (NTRS)
Eisler, W. J.; Klein, P. D.
1969-01-01
Multipurpose digital delay timer simultaneously controls both a buffer pump and a fraction-collector. Timing and control may be in 30-second increments for up to 15 hours. Use of glassware and scintillation vials make it economical.
Stotland, Aleksandr; Gottlieb, Roberta A.
2016-01-01
In order to maintain an efficient, energy-producing network in the heart, dysfunctional mitochondria are cleared through the mechanism of autophagy, which is closely linked with mitochondrial biogenesis; these, together with fusion and fission comprise a crucial process known as mitochondrial turnover. Until recently, the lack of molecular tools and methods available to researchers has impeded in vivo investigations of turnover. To investigate the process at the level of a single mitochondrion, our laboratory has developed the MitoTimer protein. Timer is a mutant of DsRed fluorescent protein characterized by transition from green fluorescence to a more stable red conformation over 48 h, and its rate of maturation is stable under physiological conditions. We fused the Timer cDNA with the inner mitochondrial membrane signal sequence and placed it under the control of a cardiac-restricted promoter. This construct was used to create the alpha-MHC-MitoTimer mice. Surprisingly, initial analysis of the hearts from these mice demonstrated a high degree of heterogeneity in the ratio of red-to-green fluorescence of MitoTimer in cardiac tissue. Further, scattered solitary mitochondria within cardiomyocytes display a much higher red-to-green fluorescence (red-shifted) relative to other mitochondria in the cell, implying a block in import of newly synthesized MitoTimer likely due to lower membrane potential. These red-shifted mitochondria may represent older, senescent mitochondria. Concurrently, the cardiomyocytes also contain a subpopulation of mitochondria that display a lower red-to-green fluorescence (green-shifted) relative to other mitochondria, indicative of germinal mitochondria that are actively engaged in import of newly-synthesized mito-targeted proteins. These mitochondria can be isolated and sorted from the heart by flow cytometry for further analysis. Initial studies suggest that these mice represent an elegant tool for the investigation of mitochondrial turnover in the heart. PMID:26654779
A COMPARISON OF THE EFFECTS OF BRIEF RULES, A TIMER, AND PREFERRED TOYS ON SELF-CONTROL
Newquist, Matthew H; Dozier, Claudia L; Neidert, Pamela L
2012-01-01
Some children make impulsive choices (i.e., choose a small but immediate reinforcer over a large but delayed reinforcer). Previous research has shown that delay fading, providing an alternative activity during the delay, teaching participants to repeat a rule during the delay, combining delay fading with an alternative activity, and combining delay fading with a countdown timer are effective for increasing self-control (i.e., choosing the large but delayed reinforcer over the small but immediate reinforcer). The purpose of the current study was to compare the effects of various interventions in the absence of delay fading (i.e., providing brief rules, providing a countdown timer during the delay, or providing preferred toys during the delay) on self-control. Results suggested that providing brief rules or a countdown timer during the delay was ineffective for enhancing self-control. However, providing preferred toys during the delay effectively enhanced self-control. PMID:23060664
A comparison of the effects of brief rules, a timer, and preferred toys on self-control.
Newquist, Matthew H; Dozier, Claudia L; Neidert, Pamela L
2012-01-01
Some children make impulsive choices (i.e., choose a small but immediate reinforcer over a large but delayed reinforcer). Previous research has shown that delay fading, providing an alternative activity during the delay, teaching participants to repeat a rule during the delay, combining delay fading with an alternative activity, and combining delay fading with a countdown timer are effective for increasing self-control (i.e., choosing the large but delayed reinforcer over the small but immediate reinforcer). The purpose of the current study was to compare the effects of various interventions in the absence of delay fading (i.e., providing brief rules, providing a countdown timer during the delay, or providing preferred toys during the delay) on self-control. Results suggested that providing brief rules or a countdown timer during the delay was ineffective for enhancing self-control. However, providing preferred toys during the delay effectively enhanced self-control.
Time-series intervention analysis of pedestrian countdown timer effects.
Huitema, Bradley E; Van Houten, Ron; Manal, Hana
2014-11-01
Pedestrians account for 40-50% of traffic fatalities in large cities. Several previous studies based on relatively small samples have concluded that Pedestrian Countdown Timers (PCT) may reduce pedestrian crashes at signalized intersections, but other studies report no reduction. The purposes of the present article are to (1) describe a new methodology to evaluate the effectiveness of introducing PCT signals and (2) to present results of applying this methodology to pedestrian crash data collected in a large study carried out in Detroit, Michigan. The study design incorporated within-unit as well as between-unit components. The main focus was on dynamic effects that occurred within the PCT unit of 362 treated sites during the 120 months of the study. An interrupted time-series analysis was developed to evaluate whether change in crash frequency depended upon of the degree to which the countdown timers penetrated the treatment unit. The between-unit component involved comparisons between the treatment unit and a control unit. The overall conclusion is that the introduction of PCT signals in Detroit reduced pedestrian crashes to approximately one-third of the preintervention level. The evidence for this reductionis strong and the change over time was shown to be a function of the extent to which the timers were introduced during the intervention period. There was no general drop-off in crash frequency throughout the baseline interval of over five years; only when the PCT signals were introduced in large numbers was consistent and convincing crash reduction observed. Correspondingly, there was little evidence of change in the control unit. Copyright © 2014. Published by Elsevier Ltd.
A SPICE2 Model for the M732 Analog Timer Integrated Circuit.
1982-06-01
I AD-All? 019 ARMY ARMAMENT RESEARCH AND DEVELOPMENT C01MAND DOVER-ETC F/ S 1/ I A SPICES MODEL FOR THE M739 ANALOG TIMER INTEGRATED CIRCUIT. (U) I...JUN $I .J P TOBAK UNCLASSIFIED AR ID-20Di S I-AD-E06 3 NL ADI- A SPICE2 MODEL FOR THE M3 ANALOG TIMR INTERNATED CIRCIT, JOHN P. TOMA DTIC JUNE 1992 13...ARrIID-TR-82001 -;AZ/ 4 " 4. TITLE (and Subtitle) S . TYPE OF REPORT & PERIOD COVERED A SPICE2 MODEL FOR THE M732 ANALOG TIMER Final INTEGRATED CIRCUIT
Cumulative Timers for Microprocessors
NASA Technical Reports Server (NTRS)
Battle, John O.
2007-01-01
It has been proposed to equip future microprocessors with electronic cumulative timers, for essentially the same reasons for which land vehicles are equipped with odometers (total-distance-traveled meters) and aircraft are equipped with Hobbs meters (total-engine-operating time meters). Heretofore, there has been no way to determine the amount of use to which a microprocessor (or a product containing a microprocessor) has been subjected. The proposed timers would count all microprocessor clock cycles and could only be read by means of microprocessor instructions but, like odometers and Hobbs meters, could never be reset to zero without physically damaging the chip.
A Cell Programmable Assay (CPA) chip.
Ju, Jongil; Warrick, Jay; Beebe, David J
2010-08-21
This article describes two kinds of "Cell Programmable Assay" (CPA) chips that utilize passive pumping for the culture and autonomous staining of cells to simply common protocols. One is a single timer channel CPA (sCPA) chip that has one timer channel and one main channel containing a cell culture chamber. The sCPA is used to culture and stain cells using Hoechst nuclear staining dye (a 2 step staining process). The other is a dual timer channel CPA (dCPA) chip that has two timer channels and one main channel with a chamber for cell culture. The dCPA is used here to culture, fix, permeablize, and stain cells using DAPI. The additional timer channel of the dCPA chip allows for automation of 3 steps. The CPA chips were successfully evaluated using HEK 293 cells. In addition, we provide a simplified equation for tuning or redesigning CPA chips to meet the needs of a variety of protocols that may require different timings. The equation is easy to use as it only depends upon the dimensions of microchannel and the volume of the reagent drops. The sCPA and dCPA chips can be readily modified to apply to a wide variety of common cell culture methods and procedures.
Ti, Xiaonan; Tani, Naoki; Isobe, Minoru; Kai, Hidenori
2006-05-01
The TIME (Time Interval Measuring Enzyme) ATPase measures time intervals in accordance with diapause development, which indispensably requires cold for resumption of embryonic development in the silkworm (Bombyx mori). The PIN (Peptidyl Inhibitory Needle) peptide regulates the time measurement function of TIME. In the present study we investigated the interaction between TIME and PIN in order to address the mechanism of diapause development. When TIME was isolated from eggs later than 12 days after oviposition, transient bursts of ATPase activity occurred 18h after isolation of TIME, and the younger the eggs and pupal ovaries from which TIME was isolated, the earlier the bursts of ATPase activity appeared. However, no interval-timer activation of ATPase occurred in ovaries earlier than 6 days after pupation. Similar patterns of ATPase activity occurred in test tubes after mixing TIME with PIN. The shorter the time PIN was mixed with TIME, the earlier the ATPase activity appeared. The timer may be built into the protein conformation of TIME, and PIN (which is present in ovaries beginning 6 days after pupation) appears able to alter this timer conformation through pupal stages to laid eggs. We discuss the possible mechanism of diapause development in relation to the timer mechanism of TIME.
Reliability of a Shuttle reaction timer
NASA Technical Reports Server (NTRS)
Hays, Russell D.; Mazzocca, Augustus D.; Rashid, Michael; Siconolfi, Steven F.
1992-01-01
Reaction, movement, and task times refer to the times needed to initially respond to a stimulus, make the specific movement, and complete the entire task. This study evaluated the reliability of a simple reaction timer designed to mimic a Space Shuttle task (turning on an overhead switch).
Review and Evaluation of Mindfulness-Based iPhone Apps
Kavanagh, David J; Hides, Leanne; Stoyanov, Stoyan R
2015-01-01
Background There is growing evidence for the positive impact of mindfulness on wellbeing. Mindfulness-based mobile apps may have potential as an alternative delivery medium for training. While there are hundreds of such apps, there is little information on their quality. Objective This study aimed to conduct a systematic review of mindfulness-based iPhone mobile apps and to evaluate their quality using a recently-developed expert rating scale, the Mobile Application Rating Scale (MARS). It also aimed to describe features of selected high-quality mindfulness apps. Methods A search for “mindfulness” was conducted in iTunes and Google Apps Marketplace. Apps that provided mindfulness training and education were included. Those containing only reminders, timers or guided meditation tracks were excluded. An expert rater reviewed and rated app quality using the MARS engagement, functionality, visual aesthetics, information quality and subjective quality subscales. A second rater provided MARS ratings on 30% of the apps for inter-rater reliability purposes. Results The “mindfulness” search identified 700 apps. However, 94 were duplicates, 6 were not accessible and 40 were not in English. Of the remaining 560, 23 apps met inclusion criteria and were reviewed. The median MARS score was 3.2 (out of 5.0), which exceeded the minimum acceptable score (3.0). The Headspace app had the highest average score (4.0), followed by Smiling Mind (3.7), iMindfulness (3.5) and Mindfulness Daily (3.5). There was a high level of inter-rater reliability between the two MARS raters. Conclusions Though many apps claim to be mindfulness-related, most were guided meditation apps, timers, or reminders. Very few had high ratings on the MARS subscales of visual aesthetics, engagement, functionality or information quality. Little evidence is available on the efficacy of the apps in developing mindfulness. PMID:26290327
Review and Evaluation of Mindfulness-Based iPhone Apps.
Mani, Madhavan; Kavanagh, David J; Hides, Leanne; Stoyanov, Stoyan R
2015-08-19
There is growing evidence for the positive impact of mindfulness on wellbeing. Mindfulness-based mobile apps may have potential as an alternative delivery medium for training. While there are hundreds of such apps, there is little information on their quality. This study aimed to conduct a systematic review of mindfulness-based iPhone mobile apps and to evaluate their quality using a recently-developed expert rating scale, the Mobile Application Rating Scale (MARS). It also aimed to describe features of selected high-quality mindfulness apps. A search for "mindfulness" was conducted in iTunes and Google Apps Marketplace. Apps that provided mindfulness training and education were included. Those containing only reminders, timers or guided meditation tracks were excluded. An expert rater reviewed and rated app quality using the MARS engagement, functionality, visual aesthetics, information quality and subjective quality subscales. A second rater provided MARS ratings on 30% of the apps for inter-rater reliability purposes. The "mindfulness" search identified 700 apps. However, 94 were duplicates, 6 were not accessible and 40 were not in English. Of the remaining 560, 23 apps met inclusion criteria and were reviewed. The median MARS score was 3.2 (out of 5.0), which exceeded the minimum acceptable score (3.0). The Headspace app had the highest average score (4.0), followed by Smiling Mind (3.7), iMindfulness (3.5) and Mindfulness Daily (3.5). There was a high level of inter-rater reliability between the two MARS raters. Though many apps claim to be mindfulness-related, most were guided meditation apps, timers, or reminders. Very few had high ratings on the MARS subscales of visual aesthetics, engagement, functionality or information quality. Little evidence is available on the efficacy of the apps in developing mindfulness.
Rand E. Eads; Mark R. Boolootian; Steven C. [Inventors] Hankin
1987-01-01
Abstract - A programmable calculator is connected to a pumping sampler by an interface circuit board. The calculator has a sediment sampling program stored therein and includes a timer to periodically wake up the calculator. Sediment collection is controlled by a Selection At List Time (SALT) scheme in which the probability of taking a sample is proportional to its...
LASSO experiment: Intercalibrations of the LASSO ranging stations
NASA Technical Reports Server (NTRS)
Gaignebet, J.; Hatat, J.-L.; Mangin, J. F.; Torre, J. M.; Klepczynski, William J.; Mccubin, L.; Wiant, J.; Rickefs, R.
1994-01-01
Presented are equations for time synchronization of laser ranging stations. The system consists of a satellite fitted with laser retroreflectors associated to a light detector and an event timer and two laser ranging stations with their own event timers. Methods of determining the Lasso intercalibration constant are given.
Timing and Trajectory in Rhythm Production
ERIC Educational Resources Information Center
Doumas, Michail; Wing, Alan M.
2007-01-01
The Wing-Kristofferson movement timing model (A. M. Wing & A. B. Kristofferson, 1973a, 1973b) distinguishes central timer and motor implementation processes. Previous studies have shown that increases in interresponse interval (IRI) variability with mean IRI are due to central timer processes, not motor implementation. The authors examine whether…
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Timers; elapsed time indicators; remaining service life indicators; minimum requirements. 84.83 Section 84.83 Public Health PUBLIC HEALTH SERVICE... indicators; remaining service life indicators; minimum requirements. (a) Elapsed time indicators shall be...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Timers; elapsed time indicators; remaining service life indicators; minimum requirements. 84.83 Section 84.83 Public Health PUBLIC HEALTH SERVICE... indicators; remaining service life indicators; minimum requirements. (a) Elapsed time indicators shall be...
Some Thermophysical Properties of Blood Components and Coolants for Frozen Blood Shipping Containers
1989-09-01
SP number by sending a DP reading. Subroutine : AutoControl Automatic control to set temperature. : Autodisplay Get ilL Thermocouple readings and...RETURN 133 AutoControl : Auto control Mode ON TIMER(ReportTime) GOSUB Autodisplay Update Screen in constant interval TIMER ON WHILE Success a 0 Turn off
Eight-Channel Continuous Timer
NASA Technical Reports Server (NTRS)
Cole, Steven
2004-01-01
A custom laboratory electronic timer circuit measures the durations of successive cycles of nominally highly stable input clock signals in as many as eight channels, for the purpose of statistically quantifying the small instabilities of these signals. The measurement data generated by this timer are sent to a personal computer running software that integrates the measurements to form a phase residual for each channel and uses the phase residuals to compute Allan variances for each channel. (The Allan variance is a standard statistical measure of instability of a clock signal.) Like other laboratory clock-cycle-measuring circuits, this timer utilizes an externally generated reference clock signal having a known frequency (100 MHz) much higher than the frequencies of the input clock signals (between 100 and 120 Hz). It counts the number of reference-clock cycles that occur between successive rising edges of each input clock signal of interest, thereby affording a measurement of the input clock-signal period to within the duration (10 ns) of one reference clock cycle. Unlike typical prior laboratory clock-cycle-measuring circuits, this timer does not skip some cycles of the input clock signals. The non-cycle-skipping feature is an important advantage because in applications that involve integration of measurements over long times for characterizing nominally highly stable clock signals, skipping cycles can degrade accuracy. The timer includes a field-programmable gate array that functions as a 20-bit counter running at the reference clock rate of 100 MHz. The timer also includes eight 20-bit latching circuits - one for each channel - at the output terminals of the counter. Each transition of an input signal from low to high causes the corresponding latching circuit to latch the count at that instant. Each such transition also sets a status flip-flop circuit to indicate the presence of the latched count. A microcontroller reads the values of all eight status flipflops and then reads the latched count for each channel for which the flip-flop indicates the presence of a count. Reading the count for each channel automatically causes the flipflop of that channel to be reset. The microcontroller places the counts in time order, identifies the channel number for each count, and transmits these data to the personal computer.
A cycle timer for testing electric vehicles
NASA Technical Reports Server (NTRS)
Soltis, R. F.
1978-01-01
A cycle timer was developed to assist the driver of an electric vehicle in more accurately following and repeating SAE driving schedules. These schedules require operating an electric vehicle in a selected stop-and-go driving cycle and repeating this cycle pattern until the vehicle ceases to meet the requirements of the cycle. The heart of the system is a programmable read-only memory (PROM) that has the required test profiles permanently recorded on plug-in cards, one card for each different driving schedule. The PROM generates a direct current analog signal that drives a speedometer displayed on one scale of a dual movement meter. The second scale of the dual movement meter displays the actual speed of the vehicle as recorded by the fifth wheel. The vehicle operator controls vehicle speed to match the desired profile speed. The PROM controls the recycle start time as well as the buzzer activation. The cycle programmer is powered by the test vehicle's 12-volt accessory battery, through a 5-volt regulator and a 12-volt dc-to-dc converter.
Measurement of "g" Using a Flashing LED
ERIC Educational Resources Information Center
Terzella, T.; Sundermier, J.; Sinacore, J.; Owen, C.; Takai, H.
2008-01-01
In one of the classic free-fall experiments, a small mass is attached to a strip of paper tape and both are allowed to fall through a spark timer, where sparks are generated at regular time intervals. Students analyze marks (dots) left on the tape by the timer, thereby generating distance-versus-time data, which they analyze to extract the…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-06
..., with aggregate size and last sale information, subscribers to ToM will also receive: Opening imbalance... information. \\3\\ Where there is an imbalance at the price at which the maximum number of contracts can trade... Timer or Imbalance Timer expires if material conditions of the market (imbalance size, ABBO price or...
Reflections on the Status of Women Faculty: Part-Timers in Baccalaureate Nursing Programs.
ERIC Educational Resources Information Center
Hawkins, Joellen W.; And Others
The use of part-time faculty in baccalaureate nursing programs and the views of part-timers about part-time employment were studies in two phases. The first phase was a descriptive exploration of the use of part-time faculty conducted in 1979 using questionnaires completed by administrative officers. Responses from administrators of 91…
NASA Technical Reports Server (NTRS)
Credeur, Leonard; Houck, Jacob A.; Capron, William R.; Lohr, Gary W.
1990-01-01
A description and results are presented of a study to measure the performance and reaction of airline flight crews, in a full workload DC-9 cockpit, flying in a real-time simulation of an air traffic control (ATC) concept called Traffic Intelligence for the Management of Efficient Runway-scheduling (TIMER). Experimental objectives were to verify earlier fast-time TIMER time-delivery precision results and obtain data for the validation or refinement of existing computer models of pilot/airborne performance. Experimental data indicated a runway threshold, interarrival-time-error standard deviation in the range of 10.4 to 14.1 seconds. Other real-time system performance parameters measured include approach speeds, response time to controller turn instructions, bank angles employed, and ATC controller message delivery-time errors.
Temporal Accuracy and Modern High Performance Processors: A Case Study Using Pentium Pro
1998-10-15
conducted. We discuss the results of our experiments and how these results will be usedfor implementing the next release of Maruti hard real - time operating system in...Even though the resolution of the APIC timer is not as good as the TSCcounter, an interruptible timer may be used in several ways in a real - time operating system . Theobjective
Two Effective Ways to Implement Wait Time. A Symposium on Wait Time.
ERIC Educational Resources Information Center
Swift, J. Nathan; And Others
The effects of instructional guides and a wait time feedback device (called a "Wait Timer") on the classroom interaction of middle school science teachers are examined. The Wait Timer, an unobtrusive indicator of wait time, is an automatic device that activates a light when a person speaks. The duration of the light at the end of a…
Research and Simulation in Support of Near Real Time/Real Time Reconnaissance RPV Systems
1977-06-01
Image 4,5.2 Raster Lines Across Image 4.5.3 Angle Projected by Displayed Image 4.6 Optical Defocusing SIMULATION CONSIDERATIONS PAGE 162 162 162...television and infrared, there are a finite number of resolution elements across the format. As a consequence, selection of a shorter optical focal...light that is scanned across and down the CRT to form a raster similar to that seen in a standard television tube. The light is optically projected
Skylab indicators (event timer) (secondary display) (four-digit metabolic display)
NASA Technical Reports Server (NTRS)
Tiberg, W.
1971-01-01
The effort expended in developing the following indicators is summarized: (1) event timer; (2) secondary display; and (3) 4 digit display (metabolic). The mechanical design, vibration analysis, and thermal analysis of all these units are identical, and descriptions pertain to all three units. All problems incurred during the program are discussed along with the recommendations, conclusions, and actions taken to rectify the situations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... filters used are specified to have a minimum collection efficiency of 99 percent for 0.3 µm (DOP... electronic timers have much better set-point resolution than mechanical timers, but require a battery backup... Collection efficiency: 99 percent minimum as measured by the DOP test (ASTM-2986) for particles of 0.3 µm...
Code of Federal Regulations, 2014 CFR
2014-07-01
... filters used are specified to have a minimum collection efficiency of 99 percent for 0.3 µm (DOP... electronic timers have much better set-point resolution than mechanical timers, but require a battery backup... Collection efficiency: 99 percent minimum as measured by the DOP test (ASTM-2986) for particles of 0.3 µm...
2004-03-01
turned off. SLEEP Set the timer for 30 seconds before scheduled transmit time, then sleep the processor. WAKE When timer trips, power up the processor...slots where none of its neighbors are schedule to transmit. This allows the sensor nodes to perform a simple power man- agement scheme that puts the...routing This simple case study highlights the following crucial observation: optimal traffic scheduling in energy constrained networks requires future
77 FR 35107 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-12
... devices. CSX requests relief from 49 CFR 236.109 as it applies to variable timers within the program logic... program logic of the operating software. However, CSX notes that some microprocessor-based equipment have.../check sum/universal control number of the existing location specific application logic to the previously...
NASA Astrophysics Data System (ADS)
Saint-Jalmes, Hervé; Barjhoux, Yves
1982-01-01
We present a 10 line-7 MHz timing generator built on a single board around two LSI timer chips interfaced to a 16-bit microcomputer. Once programmed from the host computer, this device is able to generate elaborate logic sequences on its 10 output lines without further interventions from the CPU. Powerful architecture introduces new possibilities over conventional memory-based timing simulators and word generators. Loop control on a given sequence of events, loop nesting, and various logic combinations can easily be implemented through a software interface, using a symbolic command language. Typical applications of such a device range from development, emulation, and test of integrated circuits, circuit boards, and communication systems to pulse-controlled instrumentation (radar, ultrasonic systems). A particular application to a pulsed Nuclear Magnetic Resonance (NMR) spectrometer is presented, along with customization of the device for generating four-channel radio-frequency pulses and the necessary sequence for subsequent data acquisition.
ERIC Educational Resources Information Center
Riegelman, Elizabeth D.; And Others
The effects of an oven timer as an antecedent stimulus on study behavior and concurrent completion and accuracy of reading and writing assignments were investigated for an 8-year-old first grade repeater who lacked motivation. Following baseline observations during which the teacher recorded study behavior and collected assignments with no…
ERIC Educational Resources Information Center
Pollington, Mary
A study compared the working conditions of part-time English teachers at Brigham Young University (BYU) and Utah Valley Community College (UVCC). At BYU more than half of the advanced writing classes are taught by part-timers, who make up 27% of the English department, and women part-timers outnumber men four to one. At UVCC there are about as…
Choi, Tayoung; Ganapathy, Sriram; Jung, Jaehak; Savage, David R.; Lakshmanan, Balasubramanian; Vecasey, Pamela M.
2013-04-16
A system and method for detecting a low performing cell in a fuel cell stack using measured cell voltages. The method includes determining that the fuel cell stack is running, the stack coolant temperature is above a certain temperature and the stack current density is within a relatively low power range. The method further includes calculating the average cell voltage, and determining whether the difference between the average cell voltage and the minimum cell voltage is greater than a predetermined threshold. If the difference between the average cell voltage and the minimum cell voltage is greater than the predetermined threshold and the minimum cell voltage is less than another predetermined threshold, then the method increments a low performing cell timer. A ratio of the low performing cell timer and a system run timer is calculated to identify a low performing cell.
Unusual way of suicide by carbon monoxide. Case Report.
Zelený, Michal; Pivnička, Jan; Šindler, Martin; Kukleta, Pavel
2015-01-01
Authors discuss the case of a suicide of a 29-year-old man caused by carbon monoxide (CO) intoxication. What the authors found interesting was the unusual way of committing suicide that required good technical skills and expert knowledge. The level of carboxyhemoglobin (COHb) in the blood of the deceased man was routinely determined by the modified method by Blackmoore (1970), using gas chromatography/thermal conductivity detection. The level of saturation of the hemoglobin by CO in the collected blood sample is determined relatively to the same sample saturated to 100%. In the blood sample of the deceased man the lethal concentration of COHb of 76.5% was determined. Within the following examinations the blood alcohol concentration of 0.05 g.kg(-1) was determined. Further analysis revealed traces of sertraline, its metabolite N-desmethylsertraline, omeprazole and caffeine in the liver tissue, traces of N-desmethylsertraline, ibuprofen and caffeine in urine sample, and only traces of caffeine in the stomach content and blood samples were proved. To commit suicide the man used a sophisticated double container-system equipped with a timer for controlled generation of CO based on the chemical reaction of concentrated sulphuric acid and formic acid. The used timer was set by an electromechanical timer switch that triggered the fatal reaction of the acids while the man was sleeping. The authors discuss an unusual case of suicide by CO intoxication rarely seen in the area of forensic medicine and toxicology that is specific due to its sophisticated way of execution.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 4.0 with pH 4.0 buffer and pH 7 with pH 7.0 buffer. 3.350-mL burette for 1.0 N sodium hydroxide. 3.... 3.8Timer. 4. Reagents 4.1Standardized 1.0 N sodium hydroxide solution. 4.2Hydroxylamine.... Start the timer. 5.6Stir for 5 minutes. Titrate to pH 4.0 with standardized 1.0 N sodium hydroxide...
Rangefinder, Laser AN/GVS-5( )
1977-06-01
capacitor, which is proportional to optical energy, is compared to two reference voltages. One comparison is made in the LO power comparator (U1-A...and the other in the NORMAL power comparator (U1-B). 108 OSC. FREQ. RANGE S1A ADJ. ADJ.SB O OSCILLATOR RANGE TIMER MLII:T 2 ELECTRON ICS BOARD PULSE (2...RCVR 1 PULSE and RCVR 2 PULSE modes an oscillator (U4A) is turned on by removal of a short across an integrator. This oscillator triggers the range timer
NASA Astrophysics Data System (ADS)
Badruzaman; Rusdiana, A.; Gilang, M. R.; Martini, T.
2017-03-01
This study is purposed to make a software and hardware instrument in controlling the velocity of 50 meters free style swimming speed measurement based on microcontroller Arduino Uno. The writer uses 6 participants of advanced 2015 college students of sport education. The materials he uses are electronical series of microcontroller Arduino Uno base, laser sensors shone on light dependent resistor, laser receiver functions as a detector of laser cutting block, cables as connector transfering the data. This device consist of 4 installable censors in every 10 meters with the result of swimming speed showed on the monitors using visual basic 6.0 software. This instrument automatically works when the buzzer is pushed and also runs the timer on the application. For the procedure, the writer asks the participants to swim in free style along 50 meters. When the athlete swims, they will cut the laser of every censors so that it gives a signal to stop the running timer on the monitoring application. The output result the writer gets from this used instrument is to know how fast a swimmer swim in maximum speed, to know the time and distance of acceleration and decelaration that happens. The result of validity instrument shows 0,605 (high), while the reliability is 0,833 (very high).
Time Series Data Visualization in World Wide Telescope
NASA Astrophysics Data System (ADS)
Fay, J.
WorldWide Telescope provides a rich set of timer series visualization for both archival and real time data. WWT consists of both interactive desktop tools for interactive immersive visualization and HTML5 web based controls that can be utilized in customized web pages. WWT supports a range of display options including full dome, power walls, stereo and virtual reality headsets.
Survey of Part-Time Faculty at Ferris State College.
ERIC Educational Resources Information Center
Snyder, Chryl A.; Terzin, Margaret A.
The status of part-time faculty at Ferris State College during the 1984 fall quarter was investigated. A total of 53 part-timers completed the survey, which was based on the concerns of members of the Ferris Professional Women's organization. It was found that part-time faculty members were likely to be female, 36-50 years old, married, with a…
Binary processing and display concepts for low-cost Omega receivers. [airborne systems simulation
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1974-01-01
A description is given of concepts related to plans for developing a low-cost, all-digital Omega receiver capable of offering to the small-aircraft pilot a reliable and accurate navigation aid. The receiver base considered includes a receiver front-end module, a receiver control module, a memory-aided phase-locked loop module, a housekeeping timer module, and a synthesizer module.
A dynamic-based measurement of a spring constant with a smartphone light sensor
NASA Astrophysics Data System (ADS)
Pili, Unofre
2018-05-01
An accessible smartphone-based experimental set-up for measuring a spring constant is presented. Using the smartphone ambient light sensor as the motion timer that allows for the measurement of the period of oscillations of a vertical spring-mass oscillator we found the spring constant to be 27.3 +/- 0.2 N m-1. This measurement is in a satisfactory agreement with another experimental value, 26.7 +/- 0.1 N m-1, obtained via the traditional static method.
Variable Delay Testing Using ONE
NASA Technical Reports Server (NTRS)
Ishac, Joseph
2002-01-01
This paper investigates the effect of long and changing propagation delays on the performance of TCP file transfers. Tests are performed with machines that emulate communication from a low/medium-earth satellite to Earth by way of a geosynchronous satellite. As a result of these tests, we find that TCP is fairly robust to varying delays given a high enough TCP timer granularity. However, performance degrades noticeably for larger file transfers when a finer timer granularity is used. Such results have also been observed in previous simulations by other researchers, and thus, this work serves as an extension of those results.
2013-03-21
and timers use a time-based estimate to predict how many people are in a facility at a given point in the day. CO2-based DCV systems measure CO2...energy and latent energy from the outside air when the coils’ surface temperature is below the dew point of the air passing over the coils (ASHRAE...model assumes that the dew point water saturation pressure is the same as the dry-bulb water vapor pressure, consistent with a typical ASHRAE
Development and testing of a portable wind sensitive directional air sampler
NASA Technical Reports Server (NTRS)
Deyo, J.; Toma, J.; King, R. B.
1975-01-01
A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.
Monomeric fluorescent timers that change color from blue to red report on cellular trafficking.
Subach, Fedor V; Subach, Oksana M; Gundorov, Illia S; Morozova, Kateryna S; Piatkevich, Kiryl D; Cuervo, Ana Maria; Verkhusha, Vladislav V
2009-02-01
Based on the mechanism for chromophore formation in red fluorescent proteins, we developed three mCherry-derived monomeric variants, called fluorescent timers (FTs), that change their fluorescence from the blue to red over time. These variants exhibit distinctive fast, medium and slow blue-to-red chromophore maturation rates that depend on the temperature. At 37 degrees C, the maxima of the blue fluorescence are observed at 0.25, 1.2 and 9.8 h for the purified fast-FT, medium-FT and slow-FT, respectively. The half-maxima of the red fluorescence are reached at 7.1, 3.9 and 28 h, respectively. The FTs show similar timing behavior in bacteria, insect and mammalian cells. Medium-FT allowed for tracking of the intracellular dynamics of the lysosome-associated membrane protein type 2A (LAMP-2A) and determination of its age in the targeted compartments. The results indicate that LAMP-2A transport through the plasma membrane and early or recycling endosomes to lysosomes is a major pathway for LAMP-2A trafficking.
NASA Astrophysics Data System (ADS)
Crimp, Steven; Jin, Huidong; Kokic, Philip; Bakar, Shuvo; Nicholls, Neville
2018-04-01
Anthropogenic climate change has already been shown to effect the frequency, intensity, spatial extent, duration and seasonality of extreme climate events. Understanding these changes is an important step in determining exposure, vulnerability and focus for adaptation. In an attempt to support adaptation decision-making we have examined statistical modelling techniques to improve the representation of global climate model (GCM) derived projections of minimum temperature extremes (frosts) in Australia. We examine the spatial changes in minimum temperature extreme metrics (e.g. monthly and seasonal frost frequency etc.), for a region exhibiting the strongest station trends in Australia, and compare these changes with minimum temperature extreme metrics derived from 10 GCMs, from the Coupled Model Inter-comparison Project Phase 5 (CMIP 5) datasets, and via statistical downscaling. We compare the observed trends with those derived from the "raw" GCM minimum temperature data as well as examine whether quantile matching (QM) or spatio-temporal (spTimerQM) modelling with Quantile Matching can be used to improve the correlation between observed and simulated extreme minimum temperatures. We demonstrate, that the spTimerQM modelling approach provides correlations with observed daily minimum temperatures for the period August to November of 0.22. This represents an almost fourfold improvement over either the "raw" GCM or QM results. The spTimerQM modelling approach also improves correlations with observed monthly frost frequency statistics to 0.84 as opposed to 0.37 and 0.81 for the "raw" GCM and QM results respectively. We apply the spatio-temporal model to examine future extreme minimum temperature projections for the period 2016 to 2048. The spTimerQM modelling results suggest the persistence of current levels of frost risk out to 2030, with the evidence of continuing decadal variation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grier, H.E.
1985-09-01
An automatic remote-control system armed and fired the bomb and sent out a sequence of time signals to experimental equipment on the atoll. A central station at Parry Island sent signals via submarine cables to a timer station on a shot island. The timer station controlled signals to the zero station and to experiments on the island, and through auxiliary stations, it also controlled signal distribution on adjacent islands. Light-sensitive triggering units for apparatus and for accurate standard zero-time reference were provided in the form of Blue Boxes, or fiducial markers.
Measurand transient signal suppressor
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr. (Inventor)
1994-01-01
A transient signal suppressor for use in a controls system which is adapted to respond to a change in a physical parameter whenever it crosses a predetermined threshold value in a selected direction of increasing or decreasing values with respect to the threshold value and is sustained for a selected discrete time interval is presented. The suppressor includes a sensor transducer for sensing the physical parameter and generating an electrical input signal whenever the sensed physical parameter crosses the threshold level in the selected direction. A manually operated switch is provided for adapting the suppressor to produce an output drive signal whenever the physical parameter crosses the threshold value in the selected direction of increasing or decreasing values. A time delay circuit is selectively adjustable for suppressing the transducer input signal for a preselected one of a plurality of available discrete suppression time and producing an output signal only if the input signal is sustained for a time greater than the selected suppression time. An electronic gate is coupled to receive the transducer input signal and the timer output signal and produce an output drive signal for energizing a control relay whenever the transducer input is a non-transient signal which is sustained beyond the selected time interval.
The System Power Control Unit Based on the On-Chip Wireless Communication System
Li, Tiefeng; Ma, Caiwen; Li, WenHua
2013-01-01
Currently, the on-chip wireless communication system (OWCS) includes 2nd-generation (2G), 3rd-generation (3G), and long-term evolution (LTE) communication subsystems. To improve the power consumption of OWCS, a typical architecture design of system power control unit (SPCU) is given in this paper, which can not only make a 2G, a 3G, and an LTE subsystems enter sleep mode, but it can also wake them up from sleep mode via the interrupt. During the sleep mode period, either the real-time sleep timer or the global system for mobile (GSM) communication sleep timer can be used individually to arouse the corresponding subsystem. Compared to previous sole voltage supplies on the OWCS, a 2G, a 3G, or an LTE subsystem can be independently configured with three different voltages and frequencies in normal work mode. In the meantime, the voltage supply monitor, which is an important part in the SPCU, can significantly guard the voltage of OWCS in real time. Finally, the SPCU may implement dynamic voltage and frequency scaling (DVFS) for a 2G, a 3G, or an LTE subsystem, which is automatically accomplished by the hardware. PMID:23818835
The system power control unit based on the on-chip wireless communication system.
Li, Tiefeng; Ma, Caiwen; Li, WenHua
2013-01-01
Currently, the on-chip wireless communication system (OWCS) includes 2nd-generation (2G), 3rd-generation (3G), and long-term evolution (LTE) communication subsystems. To improve the power consumption of OWCS, a typical architecture design of system power control unit (SPCU) is given in this paper, which can not only make a 2G, a 3G, and an LTE subsystems enter sleep mode, but it can also wake them up from sleep mode via the interrupt. During the sleep mode period, either the real-time sleep timer or the global system for mobile (GSM) communication sleep timer can be used individually to arouse the corresponding subsystem. Compared to previous sole voltage supplies on the OWCS, a 2G, a 3G, or an LTE subsystem can be independently configured with three different voltages and frequencies in normal work mode. In the meantime, the voltage supply monitor, which is an important part in the SPCU, can significantly guard the voltage of OWCS in real time. Finally, the SPCU may implement dynamic voltage and frequency scaling (DVFS) for a 2G, a 3G, or an LTE subsystem, which is automatically accomplished by the hardware.
On Estimating End-to-End Network Path Properties
NASA Technical Reports Server (NTRS)
Allman, Mark; Paxson, Vern
1999-01-01
The more information about current network conditions available to a transport protocol, the more efficiently it can use the network to transfer its data. In networks such as the Internet, the transport protocol must often form its own estimates of network properties based on measurements per-formed by the connection endpoints. We consider two basic transport estimation problems: determining the setting of the retransmission timer (RTO) for are reliable protocol, and estimating the bandwidth available to a connection as it begins. We look at both of these problems in the context of TCP, using a large TCP measurement set [Pax97b] for trace-driven simulations. For RTO estimation, we evaluate a number of different algorithms, finding that the performance of the estimators is dominated by their minimum values, and to a lesser extent, the timer granularity, while being virtually unaffected by how often round-trip time measurements are made or the settings of the parameters in the exponentially-weighted moving average estimators commonly used. For bandwidth estimation, we explore techniques previously sketched in the literature [Hoe96, AD98] and find that in practice they perform less well than anticipated. We then develop a receiver-side algorithm that performs significantly better.
Measuring In-Situ Mdf Velocity Of Detonation
Horine, Frank M.; James, Jr., Forrest B.
2005-10-25
A system for determining the velocity of detonation of a mild detonation fuse mounted on the surface of a device includes placing the device in a predetermined position with respect to an apparatus that carries a couple of sensors that sense the passage of a detonation wave at first and second spaced locations along the fuse. The sensors operate a timer and the time and distance between the locations is used to determine the velocity of detonation. The sensors are preferably electrical contacts that are held spaced from but close to the fuse such that expansion of the fuse caused by detonation causes the fuse to touch the contact, causing an electrical signal to actuate the timer.
An Experimental Investigation of Acoustic Cavitation in Gaseous Liquids
1990-11-08
a time-to-amplitude converter and an analog-to- digital data acquisition system based on a microcomputer. IL B. Acoustic Levitation Apparatus L...reading the RMS -ioltage from a Fluke 8600A digital multimeter to which the pill transducer was connected. This voltage was read via a GPIB interface by...micrometer microscope model M110A was used. The rise-time was measured with a digital timer which was activated by the same push-button switch used to turn
A simple pendulum-based measurement of g with a smartphone light sensor
NASA Astrophysics Data System (ADS)
Pili, Unofre; Violanda, Renante
2018-07-01
A quick and very accessible method for the measurement of acceleration due to gravity is presented. The experimental set-up employs a smartphone ambient light sensor as the motion timer for measuring the period of a simple pendulum. This allowed us to obtain an experimental value, 9.72 + 0.05 m s‑2, for the gravitational acceleration which is in good agreement with the local theoretical value of 9.78 m s‑2.
Astable Oscillator Circuits using Silicon-on-Insulator Timer Chip for Wide Range Temperature Sensing
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Culley, Dennis; Hammoud, Ahmad; Elbuluk, Malik
2008-01-01
Two astable oscillator circuits were constructed using a new silicon-on-insulator (SOI) 555 timer chip for potential use as a temperature sensor in harsh environments encompassing jet engine and space mission applications. The two circuits, which differed slightly in configuration, were evaluated between -190 and 200 C. The output of each circuit was made to produce a stream of rectangular pulses whose frequency was proportional to the sensed temperature. The preliminary results indicated that both circuits performed relatively well over the entire test temperature range. In addition, after the circuits were subjected to limited thermal cycling over the temperature range of -190 to 200 C, the performance of either circuit did not experience any significant change.
With proper installation, programming, and maintenance, homeowners and businesses can use WaterSense labeled controllers instead of standard clock-timer controllers on their existing systems, and no longer worry about wasted water.
Khmelinskii, Anton; Meurer, Matthias; Ho, Chi-Ting; Besenbeck, Birgit; Füller, Julia; Lemberg, Marius K.; Bukau, Bernd; Mogk, Axel; Knop, Michael
2016-01-01
Tandem fluorescent protein timers (tFTs) report on protein age through time-dependent change in color, which can be exploited to study protein turnover and trafficking. Each tFT, composed of two fluorescent proteins (FPs) that differ in maturation kinetics, is suited to follow protein dynamics within a specific time range determined by the maturation rates of both FPs. So far, tFTs have been constructed by combining slower-maturing red fluorescent proteins (redFPs) with the faster-maturing superfolder green fluorescent protein (sfGFP). Toward a comprehensive characterization of tFTs, we compare here tFTs composed of different faster-maturing green fluorescent proteins (greenFPs) while keeping the slower-maturing redFP constant (mCherry). Our results indicate that the greenFP maturation kinetics influences the time range of a tFT. Moreover, we observe that commonly used greenFPs can partially withstand proteasomal degradation due to the stability of the FP fold, which results in accumulation of tFT fragments in the cell. Depending on the order of FPs in the timer, incomplete proteasomal degradation either shifts the time range of the tFT toward slower time scales or precludes its use for measurements of protein turnover. We identify greenFPs that are efficiently degraded by the proteasome and provide simple guidelines for the design of new tFTs. PMID:26609072
Isobe, Minoru; Kai, Hidenori; Kurahashi, Takuya; Suwan, Sathorn; Pitchayawasin-Thapphasaraphong, Suthasinee; Franz, Thomas; Tani, Naoki; Higashi, Kenichiro; Nishida, Hideo
2006-10-01
TIME-EA4 is an ATPase that measures time intervals, functioning as a diapause duration clock in diapause eggs of the silkworm, Bombyx mori. Characterization of the primary and higher structures of the TIME-EA4 would be desirable to clarify the mechanism by which the protein measures the time intervals. In our current studies, the whole sequence of TIME-EA4 has been established as that of a metallo-glycoprotein by combinational means involving peptide sequence analysis, nano-HPLC-ESI-Q-TOF-MS and MS/MS, and cDNA dictation. The amino acid sequence of TIME-EA4 showed 46-55 % homology with the reported proteins of the Cu,Zn-SOD (superoxide dismutase) family; in particular, the SOD active site (core domain) includes metal-binding amino acid ligands and a disulfide bond, and these structures are completely identical in Bombyx SOD, bovine SOD, and TIME-EA4 proteins. We found, however, that TIME-EA4 contains one more copper ion than other SODs, as was proven under neutral nondenaturing conditions. ESI mass spectrometry revealed that the timer function was not in the SOD core domain. In addition, TIME-EA4 has an attached sugar chain, which is indispensable to its functioning as a timer protein.
Impact of worktime arrangements on work-home interference among Dutch employees.
Jansen, Nicole W H; Kant, Ijmert; Nijhuis, Frans J N; Swaen, Gerard M H; Kristensen, Tage S
2004-04-01
This study examined the effects of different worktime arrangements on work-home interference while taking into account other work-related factors, private situation and health status, explored gender differences in this relation, and examined reciprocal effects between workhours and work-home interference. Data from the Maastricht cohort study on fatigue at work were used with 8 months of follow-up (N=6947 at baseline). Worktime arrangements were related to work-home interference among the men and women, even after control for confounding. As compared with daywork, baseline shiftwork was associated with higher work-home interference over time. Within daywork, full-time work was prospectively related to higher work-home interference than part-time work was. For full-timers, baseline overtime work, hours of overtime work, change in number of workhours, and commuting time were related to higher work-home interference over time, whereas compensation for overtime work, familiarity with work roster, ability to take a day off, and a decrease in workhours at own request were associated with less work-home interference. For the part-timers, baseline overtime work and commuting time were related to higher work-home interference over time, whereas compensation for overtime, flexible workhours, and ability to take a day off were protective against work-home interference. Reciprocal relations between work-home interference and workhours were also found. Worktime arrangements are clearly related to work-home interference. Because reciprocal effects exist as well, important selection processes may exist. Nevertheless, specific characteristics of worktime arrangements could constitute useful tools for reducing work-home interference.
Independent Orbiter Assessment (IOA): Analysis of the displays and controls subsystem
NASA Technical Reports Server (NTRS)
Trahan, W. H.; Prust, E. E.
1987-01-01
The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Displays and Controls (D and C) subsystem hardware. The function of the D and C hardware is to provide the crew with the monitor, command, and control capabilities required for management of all normal and contingency mission and flight operations. The D and C hardware for which failure modes analysis was performed consists of the following: Acceleration Indicator (G-METER); Head Up Display (HUD); Display Driver Unit (DDU); Alpha/Mach Indicator (AMI); Horizontal Situation Indicator (HSI); Attitude Director Indicator (ADI); Propellant Quantity Indicator (PQI); Surface Position Indicator (SPI); Altitude/Vertical Velocity Indicator (AVVI); Caution and Warning Assembly (CWA); Annunciator Control Assembly (ACA); Event Timer (ET); Mission Timer (MT); Interior Lighting; and Exterior Lighting. Each hardware item was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.
Method and apparatus for measuring response time
Johanson, Edward W.; August, Charles
1985-01-01
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Method and apparatus for measuring response time
Johanson, E.W.; August, C.
1983-08-11
A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.
Advances in engineering of fluorescent proteins and photoactivatable proteins with red emission.
Piatkevich, Kiryl D; Verkhusha, Vladislav V
2010-02-01
Monomeric fluorescent proteins of different colors are widely used to study behavior and targeting of proteins in living cells. Fluorescent proteins that irreversibly change their spectral properties in response to light irradiation of a specific wavelength, or photoactivate, have become increasingly popular to image intracellular dynamics and superresolution protein localization. Until recently, however, no optimized monomeric red fluorescent proteins and red photoactivatable proteins have been available. Furthermore, monomeric fluorescent proteins, which change emission from blue to red simply with time, so-called fluorescent timers, were developed to study protein age and turnover. Understanding of chemical mechanisms of the chromophore maturation or photoactivation into a red form will further advance engineering of fluorescent timers and photoactivatable proteins with enhanced and novel properties. 2009 Elsevier Ltd. All rights reserved.
Grahn, A.R.
1993-05-11
A force sensor and related method for determining force components is described. The force sensor includes a deformable medium having a contact surface against which a force can be applied, a signal generator for generating signals that travel through the deformable medium to the contact surface, a signal receptor for receiving the signal reflected from the contact surface, a generation controller, a reception controller, and a force determination apparatus. The signal generator has one or more signal generation regions for generating the signals. The generation controller selects and activates the signal generation regions. The signal receptor has one or more signal reception regions for receiving signals and for generating detections signals in response thereto. The reception controller selects signal reception regions and detects the detection signals. The force determination apparatus measures signal transit time by timing activation and detection and, optionally, determines force components for selected cross-field intersections. The timer which times by activation and detection can be any means for measuring signal transit time. A cross-field intersection is defined by the overlap of a signal generation region and a signal reception region.
Grahn, Allen R.
1993-01-01
A force sensor and related method for determining force components. The force sensor includes a deformable medium having a contact surface against which a force can be applied, a signal generator for generating signals that travel through the deformable medium to the contact surface, a signal receptor for receiving the signal reflected from the contact surface, a generation controller, a reception controller, and a force determination apparatus. The signal generator has one or more signal generation regions for generating the signals. The generation controller selects and activates the signal generation regions. The signal receptor has one or more signal reception regions for receiving signals and for generating detections signals in response thereto. The reception controller selects signal reception regions and detects the detection signals. The force determination apparatus measures signal transit time by timing activation and detection and, optionally, determines force components for selected cross-field intersections. The timer which times by activation and detection can be any means for measuring signal transit time. A cross-field intersection is defined by the overlap of a signal generation region and a signal reception region.
ERIC Educational Resources Information Center
Poitras, Adrian W., Ed.
1979-01-01
Reviews new science equipment and products for the laboratory. Includes hand-held calculators, fiberglass fume hoods, motorized microtomy, disposable mouse cages, and electric timers. Describes 11 products total. Provides manufacturer name, address, and price. (MA)
Why have relative rates of class mobility become more equal among women in Britain?
Bukodi, Erzsébet; Goldthorpe, John H; Joshi, Heather; Waller, Lorraine
2017-09-01
In a previous paper it has been shown that across three cohorts of men and women born in Britain in 1946, 1958 and 1970 a gender difference exists in regard to relative rates of class mobility. For men these rates display an essential stability but for women they become more equal. The aim of the present paper is to shed light on the causes of this trend-or, that is, of increasing social fluidity-among women. We begin by considering a refined version of the perverse fluidity hypothesis: that is, one that proposes that part-time work leads to increasing downward worklife mobility among women that also entails downward intergenerational mobility and thus promotes greater fluidity. We do in fact find that the increase in fluidity is very largely, if not entirely, confined to women who have had at least one period of part-time work. However, a more direct test of the hypothesis is not supportive. We are then led to investigate whether it is not that part-time working itself is the crucial factor but rather that women who subsequently work part-time already differ from those who do not at entry into employment. We find that eventual full- and part-timers do not differ in their class origins nor, in any systematic way, in their educational qualifications. But there is a marked and increasing difference in the levels of employment at which they make their labour market entry. Eventual part-timers are more likely than eventual full-timers to enter in working-class positions, regardless of their class origins and qualifications. Insofar as these women are from more advantaged origins, they would appear not to seek to exploit their advantages to the same extent as do full-timers in order to advance their own work careers. And it is, then, in the downward mobility accepted by these women-who increase in number across the cohorts-that we would locate the main source of the weakening association between class origins and destinations that is revealed among women at large. © London School of Economics and Political Science 2017.
The Timer-Logger-Communicator for Continuous, Mobile Measurement of Wheelchair Pressure Reliefs
Grip, Jeffrey C.; Merbitz, Charles T.
1985-01-01
A recently developed device which provides continuous, direct monitoring of the pressure-relief performance of persons confined to wheelchairs is reported. A custom portable computer records the data, which is transferred for analysis to an Apple IIe. The mobile computer can also signal the patient to relieve pressure based on preset criteria and the patient's performance. Teaching lift-offs to prevent ischial pressure sores is the object. Data collected with the device are used clinically and for research. Examples of such data are presented. The benefits of the device are reviewed.
21 CFR 880.2930 - Apgar timer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Monitoring Devices § 880.2930... requirements concerning records, and § 820.198 of this chapter, with respect to complaint files. [63 FR 59718...
21 CFR 880.2930 - Apgar timer.
Code of Federal Regulations, 2010 CFR
2010-04-01
... GENERAL HOSPITAL AND PERSONAL USE DEVICES General Hospital and Personal Use Monitoring Devices § 880.2930... requirements concerning records, and § 820.198 of this chapter, with respect to complaint files. [63 FR 59718...
Instrumentation for Examining Microbial Response to Changes In Environmental Pressures
NASA Technical Reports Server (NTRS)
Blaich, Justin; Storrs, Aaron; Wang, Jonathan; Ouandji, Cynthia; Arismendi, Dillon; Hernandez, Juliana; Sardesh, Nina; Ibanez, Cory; Owyang, Stephanie; Gentry, Diana
2016-01-01
The Automated Adaptive Directed Evolution Chamber (AADEC) is a device that allows operators to generate a micro-scale analog of real world systems that can be used to model the local-scale effects of climate change on microbial ecosystems. The AADEC uses an artificial environment to expose cultures of micro-organisms to environmental pressures, such as UV-C radiation, chemical toxins, and temperature. The AADEC autonomously exposes micro-organisms to selection pressures. This improves upon standard manual laboratory techniques: the process can take place over a longer period of time, involve more stressors, implement real-time adjustments based on the state of the population, and minimize the risk of contamination. We currently use UV-C radiation as the main selection pressure, UV-C is well studied both for its cell and DNA damaging effects as a type of selection pressure and for its related effectiveness as a mutagen; having these functions united makes it a good choice for a proof of concept. The AADEC roadmap includes expansion to different selection pressures, including heavy metal toxicity, temperature, and other forms of radiation.The AADEC uses closed-loop control to feedback the current state of the culture to the AADEC controller that modifies selection pressure intensity during experimentation, in this case culture density and growth rate. Culture density and growth rate are determined by measuring the optical density of the culture using 600 nm light. An array of 600 nm LEDs illuminate the culture and photodiodes are used to measure the shadow on the opposite side of the chamber.Previous experiments showed that we can produce a million fold increase to UV-C radiation over seven iterations. The most recent implements a microfluidic system that can expose cultures to multiple different selection pressures, perform non-survival based selection, and autonomously perform hundreds of exposure cycles. A scalable pump system gives the ability to pump in various different growth media to individual cultures and introduce chemical toxins during experimentation; AADEC can perform freeze and thaw cycles. We improved our baseline characterization by building a custom UV-C exposure hood, a shutter operates on a preset timer allowing the user to set exposure intensity consistently for multiple iterations.
Another place, another timer: Marine species and the rhythms of life
Tessmar-Raible, Kristin; Raible, Florian; Arboleda, Enrique
2011-01-01
The marine ecosystem is governed by a multitude of environmental cycles, all of which are linked to the periodical recurrence of the sun or the moon. In accordance with these cycles, marine species exhibit a variety of biological rhythms, ranging from circadian and circatidal rhythms to circalunar and seasonal rhythms. However, our current molecular understanding of biological rhythms and clocks is largely restricted to solar-controlled circadian and seasonal rhythms in land model species. Here, we discuss the first molecular data emerging for circalunar and circatidal rhythms and present selected species suitable for further molecular analyses. We argue that a re-focus on marine species will be crucial to understand the principles, interactions and evolution of rhythms that govern a broad range of eukaryotes, including ourselves. PMID:21254149
Flywheel-Powered Mobile X-Ray Generator.
1983-03-18
38 Circuit Description .. . . . . . . . .. 40 0. Digital Tachometer Purpose . . . . . . . . . . . . . . . 47 Operation...47 Circuit Description . . . . . . . . o 47 E. High Tension Transfoner Purpose . . . . . . . . . . . . . . . 51 Operation... Circuit Purpose . . . . . . . . . . . . . . . 54 Operation . . . . . . . . . . . . . . 54 G. Tube Rotor Control Purpose ........ . 57 Operation of Timer
Kobayashi, Atsuki; Ikeda, Kei; Ogawa, Yudai; Kai, Hiroyuki; Nishizawa, Matsuhiko; Nakazato, Kazuo; Niitsu, Kiichi
2017-12-01
In this paper, we present a self-powered bio-sensing system with the capability of proximity inductive-coupling communication for supply sensing and temperature monitoring. The proposed bio-sensing system includes a biofuel cell as a power source and a sensing frontend that is associated with the CMOS integrated supply-sensing sensor. The sensor consists of a digital-based gate leakage timer, a supply-insensitive time-domain temperature sensor, and a current-driven inductive-coupling transmitter and achieves low-voltage operation. The timer converts the output voltage from a biofuel cell to frequency. The temperature sensor provides a pulse width modulation (PWM) output that is not dependent on the supply voltage, and the associated inductive-coupling transmitter enables proximity communication. A test chip was fabricated in 65 nm CMOS technology and consumed 53 μW with a supply voltage of 190 mV. The low-voltage-friendly design satisfied the performance targets of each integrated sensor without any trimming. The chips allowed us to successfully demonstrate proximity communication with an asynchronous receiver, and the measurement results show the potential for self-powered operation using biofuel cells. The analysis and experimental verification of the system confirmed their robustness.
Biggs, Peter J
2003-04-01
The calibration and monthly QA of an electron-only linear accelerator dedicated to intra-operative radiation therapy has been reviewed. Since this machine is calibrated prior to every procedure, there was no necessity to adjust the output calibration at any time except, perhaps, when the magnetron is changed, provided the machine output is reasonably stable. This gives a unique opportunity to study the dose output of the machine per monitor unit, variation in the timer error, flatness and symmetry of the beam and the energy check as a function of time. The results show that, although the dose per monitor unit varied within +/- 2%, the timer error within +/- 0.005 MU and the asymmetry within 1-2%, none of these parameters showed any systematic change with time. On the other hand, the energy check showed a linear drift with time for 6, 9, and 12 MeV (2.1, 3.5, and 2.5%, respectively, over 5 years), while at 15 and 18 MeV, the energy check was relatively constant. It is further shown that based on annual calibrations and RPC TLD checks, the energy of each beam is constant and that therefore the energy check is an exquisitely sensitive one. The consistency of the independent checks is demonstrated.
26 CFR 48.4062(a)-1 - Specific parts or accessories.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., and Taxable Fuel Automotive and Related Items § 48.4062(a)-1 Specific parts or accessories. Spark plugs, storage batteries, leaf springs, coils, timers, and tire chains, which are suitable for use on or...
Alternative Fuel News, Vol. 4, No. 4
DOT National Transportation Integrated Search
2001-02-22
The Clean Cities network is growing, and more fleets are considering alternative fuels. : Industry old-timers that have been using alternative fuels since the passage of Energy Policy : Act of 1992 are beginning to replace their used alternativ...
ERIC Educational Resources Information Center
School Science Review, 1983
1983-01-01
Provided are reviews of science equipment/apparatus. Items reviewed include: Harris Micro-ecology tubes; Harris chromosome investigation kit; Harris trycult slides; a pressure cooker with thermometer; digital pH meter; digital scaler timer; electrical compensation calorimeter; and Mains alternating current ammeter. (JN)
Impact of Machine Virtualization on Timing Precision for Performance-critical Tasks
NASA Astrophysics Data System (ADS)
Karpov, Kirill; Fedotova, Irina; Siemens, Eduard
2017-07-01
In this paper we present a measurement study to characterize the impact of hardware virtualization on basic software timing, as well as on precise sleep operations of an operating system. We investigated how timer hardware is shared among heavily CPU-, I/O- and Network-bound tasks on a virtual machine as well as on the host machine. VMware ESXi and QEMU/KVM have been chosen as commonly used examples of hypervisor- and host-based models. Based on statistical parameters of retrieved distributions, our results provide a very good estimation of timing behavior. It is essential for real-time and performance-critical applications such as image processing or real-time control.
Turning Oscillations Into Opportunities: Lessons from a Bacterial Decision Gate
NASA Astrophysics Data System (ADS)
Schultz, Daniel; Lu, Mingyang; Stavropoulos, Trevor; Onuchic, Jose'; Ben-Jacob, Eshel
2013-04-01
Sporulation vs. competence provides a prototypic example of collective cell fate determination. The decision is performed by the action of three modules: 1) A stochastic competence switch whose transition probability is regulated by population density, population stress and cell stress. 2) A sporulation timer whose clock rate is regulated by cell stress and population stress. 3) A decision gate that is coupled to the timer via a special repressilator-like loop. We show that the distinct circuit architecture of this gate leads to special dynamics and noise management characteristics: The gate opens a time-window of opportunity for competence transitions during which it generates oscillations that are turned into a chain of transition opportunities - each oscillation opens a short interval with high transition probability. The special architecture of the gate also leads to filtering of external noise and robustness against internal noise and variations in the circuit parameters.
Condition sensor system and method
NASA Technical Reports Server (NTRS)
Polhemus, J. T.; Morgan, J. E.; Mandell, A. (Inventor)
1978-01-01
The condition sensor system comprises a condition detector which produces a pulse when a parameter of the monitored condition exceeds a desired threshold. A resettable condition counter counts each pulse. A resettable timer is preset to produce a particular time frame. The counter produces a condition signal when the accumulated number of pulses within the time frame is equal to or greater than a preset count. Control means responsive to the incoming pulses and to the condition signal produce control signals that control utilization devices. After a suitable delay, the last detected pulse simultaneously resets the pulse counter and the timer, and prepares them for sensing another condition occurrence within the time frame. The invention has particular utility in the process of detecting rocking motions of blind people. A controlled, audible, bio-feedback signal is provided which constitutes a warning to the blind person that he is rocking.
Turning Oscillations Into Opportunities: Lessons from a Bacterial Decision Gate
Schultz, Daniel; Lu, Mingyang; Stavropoulos, Trevor; Onuchic, Jose'; Ben-Jacob, Eshel
2013-01-01
Sporulation vs. competence provides a prototypic example of collective cell fate determination. The decision is performed by the action of three modules: 1) A stochastic competence switch whose transition probability is regulated by population density, population stress and cell stress. 2) A sporulation timer whose clock rate is regulated by cell stress and population stress. 3) A decision gate that is coupled to the timer via a special repressilator-like loop. We show that the distinct circuit architecture of this gate leads to special dynamics and noise management characteristics: The gate opens a time-window of opportunity for competence transitions during which it generates oscillations that are turned into a chain of transition opportunities – each oscillation opens a short interval with high transition probability. The special architecture of the gate also leads to filtering of external noise and robustness against internal noise and variations in the circuit parameters. PMID:23591544
Robust Design of Biological Circuits: Evolutionary Systems Biology Approach
Chen, Bor-Sen; Hsu, Chih-Yuan; Liou, Jing-Jia
2011-01-01
Artificial gene circuits have been proposed to be embedded into microbial cells that function as switches, timers, oscillators, and the Boolean logic gates. Building more complex systems from these basic gene circuit components is one key advance for biologic circuit design and synthetic biology. However, the behavior of bioengineered gene circuits remains unstable and uncertain. In this study, a nonlinear stochastic system is proposed to model the biological systems with intrinsic parameter fluctuations and environmental molecular noise from the cellular context in the host cell. Based on evolutionary systems biology algorithm, the design parameters of target gene circuits can evolve to specific values in order to robustly track a desired biologic function in spite of intrinsic and environmental noise. The fitness function is selected to be inversely proportional to the tracking error so that the evolutionary biological circuit can achieve the optimal tracking mimicking the evolutionary process of a gene circuit. Finally, several design examples are given in silico with the Monte Carlo simulation to illustrate the design procedure and to confirm the robust performance of the proposed design method. The result shows that the designed gene circuits can robustly track desired behaviors with minimal errors even with nontrivial intrinsic and external noise. PMID:22187523
Guide to red fluorescent proteins and biosensors for flow cytometry.
Piatkevich, Kiryl D; Verkhusha, Vladislav V
2011-01-01
Since the discovery of the first red fluorescent protein (RFP), named DsRed, 12 years ago, a wide pallet of red-shifted fluorescent proteins has been cloned and biotechnologically developed into monomeric fluorescent probes for optical microscopy. Several new types of monomeric RFPs that change the emission wavelength either with time, called fluorescent timers, or after a brief irradiation with violet light, known as photoactivatable proteins, have been also engineered. Moreover, RFPs with a large Stokes shift of fluorescence emission have been recently designed. Because of their distinctive excitation and fluorescence detection conditions developed specifically for microscopy, these fluorescent probes can be suboptimal for flow cytometry. Here, we have selected and summarized the advanced orange, red, and far-red fluorescent proteins with the properties specifically required for the flow cytometry applications. Their effective brightness was calculated for the laser sources available for the commercial flow cytometers and sorters. Compatibility of the fluorescent proteins of different colors in a multiparameter flow cytometry was determined. Novel FRET pairs, utilizing RFPs, RFP-based intracellular biosensors, and their application to a high-throughput screening, are also discussed. Copyright © 2011 Elsevier Inc. All rights reserved.
Robust design of biological circuits: evolutionary systems biology approach.
Chen, Bor-Sen; Hsu, Chih-Yuan; Liou, Jing-Jia
2011-01-01
Artificial gene circuits have been proposed to be embedded into microbial cells that function as switches, timers, oscillators, and the Boolean logic gates. Building more complex systems from these basic gene circuit components is one key advance for biologic circuit design and synthetic biology. However, the behavior of bioengineered gene circuits remains unstable and uncertain. In this study, a nonlinear stochastic system is proposed to model the biological systems with intrinsic parameter fluctuations and environmental molecular noise from the cellular context in the host cell. Based on evolutionary systems biology algorithm, the design parameters of target gene circuits can evolve to specific values in order to robustly track a desired biologic function in spite of intrinsic and environmental noise. The fitness function is selected to be inversely proportional to the tracking error so that the evolutionary biological circuit can achieve the optimal tracking mimicking the evolutionary process of a gene circuit. Finally, several design examples are given in silico with the Monte Carlo simulation to illustrate the design procedure and to confirm the robust performance of the proposed design method. The result shows that the designed gene circuits can robustly track desired behaviors with minimal errors even with nontrivial intrinsic and external noise.
A Synthetic Quadrature Phase Detector/Demodulator for Fourier Transform Transform Spectrometers
NASA Technical Reports Server (NTRS)
Campbell, Joel
2008-01-01
A method is developed to demodulate (velocity correct) Fourier transform spectrometer (FTS) data that is taken with an analog to digital converter that digitizes equally spaced in time. This method makes it possible to use simple low cost, high resolution audio digitizers to record high quality data without the need for an event timer or quadrature laser hardware, and makes it possible to use a metrology laser of any wavelength. The reduced parts count and simplicity implementation makes it an attractive alternative in space based applications when compared to previous methods such as the Brault algorithm.
Validation of an ambient measurement system (AMS) for walking speed.
Varsanik, Jonathan S; Kimmel, Zebadiah M; de Moor, Carl; Gabel, Wendy; Phillips, Glenn A
2017-07-01
Walking speed is an important indicator of worsening in a variety of neurological and neuromuscular diseases, yet typically is measured only infrequently and in a clinical setting. Passive measurement of walking speed at home could provide valuable information to track the progression of many neuromuscular conditions. The purpose of this study was to validate the measurement of walking speed by a shelf-top ambient measurement system (AMS) that can be placed in a patient's home. Twenty-eight healthy adults (16 male, 12 female) were asked to walk three pre-defined routes two times each (total of 168 traversals). For each traversal, walking speed was measured simultaneously by five sources: two independent AMSs and three human timers with stopwatches. Measurements across the five sources were compared by generalised estimating equations (GEE). Correlation coefficients compared pairwise for walking speeds across the two AMSs, three human timers, and three routes all exceeded 0.86 (p < .0001), and for AMS-to-AMS exceeded 0.92 (p < .0001). Aggregated across all routes, there was no significant difference in measured walking speeds between the two AMSs (p = .596). There was a statistically significant difference between the AMSs and human timers of 8.5 cm/s (p < .0001), which is comparable to differences reported for other non-worn sensors. The tested AMS demonstrated the ability to automatically measure walking speeds comparable to manual observation and recording, which is the current standard for assessing walking speed in a clinical setting. The AMS may be used to detect changes in walking speed in community settings.
Foam-Mixing-And-Dispensing Machine
NASA Technical Reports Server (NTRS)
Chong, Keith Y.; Toombs, Gordon R.; Jackson, Richard J.
1996-01-01
Time-and-money-saving machine produces consistent, homogeneously mixed foam, enhancing production efficiency. Automatically mixes and dispenses polyurethane foam in quantities specified by weight. Consists of cart-mounted, air-driven proportioning unit; air-activated mechanical mixing gun; programmable timer/counter, and controller.
The Political Economy of Part-Time Academic Work in Canada.
ERIC Educational Resources Information Center
Rajagopal, Indhu; Farr, William D.
1989-01-01
Under continuing financial stringency, the university administration negotiates concessions with full-time faculty to satisfy their interests and maintain the stability of the system. Part-timers, excluded from the collegium, remain peripheral to these arrangements. (Author/MLW)
Heitner, Tara; Satozawa, Noboru; McLean, Kirk; Vogel, David; Cobb, Ronald R; Liu, Bing; Mahmoudi, Mithra; Finster, Silke; Larsen, Brent; Zhu, Ying; Zhou, Hongxing; Müller-Tiemann, Beate; Monteclaro, Felipe; Zhao, Xiao-Yan; Light, David R
2006-12-01
A therapeutic antibody candidate (AT-19) isolated using multivalent phage display binds native tomoregulin (TR) as a mul-timer not as a monomer. This report raises the importance of screening and selecting phage antibodies on native antigen and reemphasizes the possibility that potentially valuable antibodies are discarded when a monomeric phage display system is used for screening. A detailed live cell panning selection and screening method to isolate multivalently active antibodies is described. AT-19 is a fully human antibody recognizing the cell surface protein TR, a proposed prostate cancer target for therapeutic antibody internalization. AT-19 was isolated from a multivalent single-chain variable fragment (scFv) antibody library rescued with hyperphage. The required multivalency for isolation of AT-19 is supported by fluorescence activated cell sorting data demonstrating binding of the multivalent AT-19 phage particles at high phage concentrations and failure of monovalent particles to bind. Pure monomeric scFv AT-19 does not bind native receptor on cells, whereas dimeric scFv or immunoglobulin G binds with nanomolar affinity. The isolation of AT-19 antibody with obligate bivalent binding activity to native TR is attributed to the use of a multivalent display of scFv on phage and the method for selecting and screening by alternate use of 2 recombinant cell lines.
Learning and the Part-Time Worker.
ERIC Educational Resources Information Center
Tisdall, Caroline
1999-01-01
Part-time workers, who are primarily female, are not well served by staff development and training models that reflect values and assumptions of traditional working patterns. Part-timers face such training barriers as management attitudes, lack of time and resources, and inflexibility. (SK)
Yamada, Takahiro; Miyamoto, Naoki; Matsuura, Taeko; Takao, Seishin; Fujii, Yusuke; Matsuzaki, Yuka; Koyano, Hidenori; Umezawa, Masumi; Nihongi, Hideaki; Shimizu, Shinichi; Shirato, Hiroki; Umegaki, Kikuo
2016-07-01
To find the optimum parameter of a new beam control function installed in a synchrotron-based proton therapy system. A function enabling multiple gated irradiation in the flat top phase has been installed in a real-time-image gated proton beam therapy (RGPT) system. This function is realized by a waiting timer that monitors the elapsed time from the last gate-off signal in the flat top phase. The gated irradiation efficiency depends on the timer value, Tw. To find the optimum Tw value, gated irradiation efficiency was evaluated for each configurable Tw value. 271 gate signal data sets from 58 patients were used for the simulation. The highest mean efficiency 0.52 was obtained in TW=0.2s. The irradiation efficiency was approximately 21% higher than at TW=0s, which corresponds to ordinary synchrotron operation. The irradiation efficiency was improved in 154 (57%) of the 271 cases. The irradiation efficiency was reduced in 117 cases because the TW value was insufficient or the function introduced an unutilized wait time for the next gate-on signal in the flat top phase. In the actual treatment of a patient with a hepatic tumor at Tw=0.2s, 4.48GyE irradiation was completed within 250s. In contrast, the treatment time of ordinary synchrotron operation was estimated to be 420s. The results suggest that the multiple gated-irradiation function has potential to improve the gated irradiation efficiency and to reduce the treatment time. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Minnesota's forest statistics, 1987: an inventory update.
Jerold T. Hahn; W. Brad Smith
1987-01-01
The Minnesota 1987 inventory update, derived by using tree growth models, reports 13.5 million acres of timberland, a decline of less than 1% since 1977. This bulletin presents findings from the inventory update in tables detailing timer land area, volume, and biomass.
Primary Care Sports Medicine: A Part-Timer's Perspective.
ERIC Educational Resources Information Center
Howe, Warren B.
1988-01-01
A family practice physician describes his part-time sports medicine experience, including the multiple roles he plays as team physician, the way sports medicine is integrated into his family practice, and how it affects his professional life and peer relationships. (Author/MT)
Apparatus for Teaching Physics.
ERIC Educational Resources Information Center
Gottlieb, Herbert H., Ed.
1979-01-01
Six different pieces of physics apparatus are described: Telsa Coil for instant ignition of sodium arc lamps, Timekube, Magnetic Maps of the United States, a slinky with vertical mounting, a wave generator power supply, and a long-period timer power switch. Price and supplier are included. (BT)
A sophisticated programmable miniaturised pump for insulin delivery.
Klein, J C; Slama, G
1980-09-01
We have conceived a truly pre-programmable infusion system usable for intravenous administration of insulin in diabetic subjects. The original system has been built into a small, commercially available, syringe-pump of which only the case and the mechanical parts have been kept. The computing until has a timer, a programmable memory of 512 words by 8 bits and a digital-to-frequency converter to run the motor which drives the syringe. The memory contains 8 profiles of insulin injections stored in digital form over 64 words. Each profile is selected by the patient before eating according to the carbohydrate content of the planned meal and last about two hours, starting from and returning to the basal rate of insulin, at which it remains until next profile selection. Amount, profiles and duration of insulin injection are either mean values deduced from previous studies with a closed-loop artificial pancreas or personally fitted values; they are stored in an instantly replaceable memory cell. This device allows the patient to choose the time, nature and amount of his food intake.
Dowdy, John C; Czako, Eugene A; Stepp, Michael E; Schlitt, Steven C; Bender, Gregory R; Khan, Lateef U; Shinneman, Kenneth D; Karos, Manuel G; Shepherd, James G; Sayre, Robert M
2011-09-01
The authors compared calculations of sunlamp maximum exposure times following current USFDA Guidance Policy on the Maximum Timer Interval and Exposure Schedule, with USFDA/CDRH proposals revising these to equivalent erythemal exposures of ISO/CIE Standard Erythema Dose (SED). In 2003, [USFDA/CDRH proposed replacing their unique CDRH/Lytle] erythema action spectrum with the ISO/CIE erythema action spectrum and revising the sunlamp maximum exposure timer to 600 J m(-2) ISO/CIE effective dose, presented as being biologically equivalent. Preliminary analysis failed to confirm said equivalence, indicating instead ∼38% increased exposure when applying these proposed revisions. To confirm and refine this finding, a collaboration of tanning bed and UV lamp manufacturers compiled 89 UV spectra representing a broad sampling of U.S. indoor tanning equipment. USFDA maximum recommended exposure time (Te) per current sunlamp guidance and CIE erythemal effectiveness per ISO/CIE standard were calculated. The CIE effective dose delivered per Te averaged 456 J(CIE) m(-2) (SD = 0.17) or ∼4.5 SED. The authors found that CDRH's proposed 600 J(CIE) m(-2) recommended maximum sunlamp exposure exceeds current Te erythemal dose by ∼33%. The current USFDA 0.75 MED initial exposure was ∼0.9 SED, consistent with 1.0 SED initial dose in existing international sunlamp standards. As no sunlamps analyzed exceeded 5 SED, a revised maximum exposure of 500 J(CIE) m(-2) (∼80% of CDRH's proposal) should be compatible with existing tanning equipment. A tanning acclimatization schedule is proposed beginning at 1 SED thrice-weekly, increasing uniformly stepwise over 4 wk to a 5 SED maximum exposure in conjunction with a tan maintenance schedule of twice-weekly 5 SED sessions, as biologically equivalent to current USFDA sunlamp policy.
Lugtenberg, Marjolein; Heiligers, Phil JM; de Jong, Judith D; Hingstman, Lammert
2006-01-01
Background Although medical specialists traditionally hold negative views towards working part-time, the practice of medicine has evolved. Given the trend towards more part-time work and that there is no evidence that it compromises the quality of care, attitudes towards part-time work may have changed as well in recent years. The aim of this paper was to examine the possible changes in attitudes towards part-time work among specialists in internal medicine between 1996 and 2004. Moreover, we wanted to determine whether these attitudes were associated with individual characteristics (age, gender, investments in work) and whether attitudes of specialists within a partnership showed more resemblance than specialists' attitudes from different partnerships. Methods Two samples were used in this study: data of a survey conducted in 1996 and in 2004. After selecting internal medicine specialists working in general hospitals in The Netherlands, the sample consisted of 219 specialists in 1996 and 363 specialists in 2004. They were sent a questionnaire, including topics on the attitudes towards part-time work. Results Internal medicine specialists' attitudes towards working part-time became slightly more positive between 1996 and 2004. Full-time working specialists in 2004 still expressed concerns regarding the investments of part-timers in overhead tasks, the flexibility of task division, efficiency, communication and continuity of care. In 1996 gender was the only predictor of the attitude, in 2004 being a full- or a part-timer, age and the time invested in work were associated with this attitude. Furthermore, specialists' attitudes were not found to cluster much within partnerships. Conclusion In spite of the increasing number of specialists working or preferring to work part-time, part-time practice among internal medicine specialists seems not to be fully accepted. The results indicate that the attitudes are no longer gender based, but are associated with age and work aspects such as the number of hours worked. Though there is little evidence to support them, negative ideas about the consequences of part-time work for the quality of care still exist. Policy should be aimed at removing the organisational difficulties related to part-time work and create a system in which part-time practice is fully integrated and accepted. PMID:17026741
High-Rate Data-Capture for an Airborne Lidar System
NASA Technical Reports Server (NTRS)
Valett, Susan; Hicks, Edward; Dabney, Philip; Harding, David
2012-01-01
A high-rate data system was required to capture the data for an airborne lidar system. A data system was developed that achieved up to 22 million (64-bit) events per second sustained data rate (1408 million bits per second), as well as short bursts (less than 4 s) at higher rates. All hardware used for the system was off the shelf, but carefully selected to achieve these rates. The system was used to capture laser fire, single-photon detection, and GPS data for the Slope Imaging Multi-polarization Photo-counting Lidar (SIMPL). However, the system has applications for other laser altimeter systems (waveform-recording), mass spectroscopy, xray radiometry imaging, high-background- rate ranging lidar, and other similar areas where very high-speed data capture is needed. The data capture software was used for the SIMPL instrument that employs a micropulse, single-photon ranging measurement approach and has 16 data channels. The detected single photons are from two sources those reflected from the target and solar background photons. The instrument is non-gated, so background photons are acquired for a range window of 13 km and can comprise many times the number of target photons. The highest background rate occurs when the atmosphere is clear, the Sun is high, and the target is a highly reflective surface such as snow. Under these conditions, the total data rate for the 16 channels combined is expected to be approximately 22 million events per second. For each photon detection event, the data capture software reads the relative time of receipt, with respect to a one-per-second absolute time pulse from a GPS receiver, from an event timer card with 0.1-ns precision, and records that information to a RAID (Redundant Array of Independent Disks) storage device. The relative time of laser pulse firings must also be read and recorded with the same precision. Each of the four event timer cards handles the throughput from four of the channels. For each detection event, a flag is recorded that indicates the source channel. To accommodate the expected maximum count rate and also handle the other extreme of very low rates occurring during nighttime operations, the software requests a set amount of data from each of the event timer cards and buffers the data. The software notes if any of the cards did not return all the data requested and then accommodates that lower rate. The data is buffered to minimize the I/O overhead of writing the data to storage. Care was taken to optimize the reads from the cards, the speed of the I/O bus, and RAID configuration.
Microbalance accurately measures extremely small masses
NASA Technical Reports Server (NTRS)
Patashnick, H.
1970-01-01
Oscillating fiber microbalance has a vibrating quartz fiber as balance arm to hold the mass to be weighed. Increasing fiber weight decreases its resonant frequency. Scaler and timer measure magnitude of the shift. This instrument withstands considerable physical abuse and has calibration stability at normal room temperatures.
ERIC Educational Resources Information Center
Science Teacher, 1989
1989-01-01
Describes classroom activities and models for migration, mutation, and isolation; a diffusion model; Bernoulli's principle; sound in a vacuum; time regression mystery of DNA; seating chart lesson plan; algae mystery laboratory; water as mass; science fair; flipped book; making a cloud; wet mount slide; timer adaptation; thread slide model; and…
Solar-Powered Water Distillation
NASA Technical Reports Server (NTRS)
Menninger, F. J.; Elder, R. J.
1985-01-01
Solar-powered still produces pure water at rate of 6,000 gallons per year. Still fully automatic and gravity-fed. Only outside electric power is timer clock and solenoid-operated valve. Still saves $5,000 yearly in energy costs and pays for itself in 3 1/2 years.
The "saying is repeating" effect: dyadic communication can generate cultural stereotypes.
Bratanova, Boyka; Kashima, Yoshi
2014-01-01
It has been long established that interpersonal communication underpins the existence of cultural stereotypes. However, research has either examined the formation of new or the maintenance of existing stereotypes. In a series of three studies, the present research bridges the gap between these phases by showing that newly formed stereotypes can spread through repeated dyadic communication with others. The stereotypic representation arose due to the audience tuning in to communication to a first audience. Further transmission to two types of subsequent audiences was simulated: a newcomer and an old-timer with an unknown attitude towards the target. A "saying-is-repeating" effect was obtained: the stereotypic representation was invariably transmitted to the newcomer, regardless of whether communicators personally believed in the bias; perceived group-level consensus moderated its transmission to the old-timer. These findings demonstrate that once a stereotypic representation is formed, it is likely to spread in a community and potentially become a cultural stereotype.
A comparison of procedures for unpairing conditioned reflexive motivating operations.
Kettering, Tracy L; Neef, Nancy A; Kelley, Michael E; Heward, William L
2018-03-01
This study compared the effectiveness of two procedures to reduce behavior evoked by a reflexive conditioned motivating operation (CMO-R). Task demands were shown to evoke escape-maintained problem behavior for 4 students with disabilities. Alternative communication responses were taught as an appropriate method to request escape and this treatment combined with extinction for problem behavior led to decreases in problem behavior for all students. A beeping timer was then arranged to temporally precede the task demand to create a CMO-R that evoked communication responses. When data showed that the sound of the timer was functioning as a CMO-R, two methods to reduce behavior evoked by a CMO-R-extinction unpairing and noncontingent unpairing-were evaluated. Results indicated that noncontingent unpairing was an effective method to reduce the evocative effects of the CMO-R. Extinction produced unsystematic effects across participants. Results are discussed in terms of abolishing CMOs and the implications of CMOs. © 2018 Society for the Experimental Analysis of Behavior.
Caunedo-Álvarez, Ángel; Romero-Vazquez, Javier; Herrerias-Gutierrez, Juan M
2008-01-01
Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency© capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency© capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile© capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture. PMID:18785278
Processing circuitry for single channel radiation detector
NASA Technical Reports Server (NTRS)
Holland, Samuel D. (Inventor); Delaune, Paul B. (Inventor); Turner, Kathryn M. (Inventor)
2009-01-01
Processing circuitry is provided for a high voltage operated radiation detector. An event detector utilizes a comparator configured to produce an event signal based on a leading edge threshold value. A preferred event detector does not produce another event signal until a trailing edge threshold value is satisfied. The event signal can be utilized for counting the number of particle hits and also for controlling data collection operation for a peak detect circuit and timer. The leading edge threshold value is programmable such that it can be reprogrammed by a remote computer. A digital high voltage control is preferably operable to monitor and adjust high voltage for the detector.
Asquith, William H.; Cleveland, Theodore G.; Roussel, Meghan C.
2011-01-01
Estimates of peak and time of peak streamflow for small watersheds (less than about 640 acres) in a suburban to urban, low-slope setting are needed for drainage design that is cost-effective and risk-mitigated. During 2007-10, the U.S. Geological Survey (USGS), in cooperation with the Harris County Flood Control District and the Texas Department of Transportation, developed a method to estimate peak and time of peak streamflow from excess rainfall for 10- to 640-acre watersheds in the Houston, Texas, metropolitan area. To develop the method, 24 watersheds in the study area with drainage areas less than about 3.5 square miles (2,240 acres) and with concomitant rainfall and runoff data were selected. The method is based on conjunctive analysis of rainfall and runoff data in the context of the unit hydrograph method and the rational method. For the unit hydrograph analysis, a gamma distribution model of unit hydrograph shape (a gamma unit hydrograph) was chosen and parameters estimated through matching of modeled peak and time of peak streamflow to observed values on a storm-by-storm basis. Watershed mean or watershed-specific values of peak and time to peak ("time to peak" is a parameter of the gamma unit hydrograph and is distinct from "time of peak") of the gamma unit hydrograph were computed. Two regression equations to estimate peak and time to peak of the gamma unit hydrograph that are based on watershed characteristics of drainage area and basin-development factor (BDF) were developed. For the rational method analysis, a lag time (time-R), volumetric runoff coefficient, and runoff coefficient were computed on a storm-by-storm basis. Watershed-specific values of these three metrics were computed. A regression equation to estimate time-R based on drainage area and BDF was developed. Overall arithmetic means of volumetric runoff coefficient (0.41 dimensionless) and runoff coefficient (0.25 dimensionless) for the 24 watersheds were used to express the rational method in terms of excess rainfall (the excess rational method). Both the unit hydrograph method and excess rational method are shown to provide similar estimates of peak and time of peak streamflow. The results from the two methods can be combined by using arithmetic means. A nomograph is provided that shows the respective relations between the arithmetic-mean peak and time of peak streamflow to drainage areas ranging from 10 to 640 acres. The nomograph also shows the respective relations for selected BDF ranging from undeveloped to fully developed conditions. The nomograph represents the peak streamflow for 1 inch of excess rainfall based on drainage area and BDF; the peak streamflow for design storms from the nomograph can be multiplied by the excess rainfall to estimate peak streamflow. Time of peak streamflow is readily obtained from the nomograph. Therefore, given excess rainfall values derived from watershed-loss models, which are beyond the scope of this report, the nomograph represents a method for estimating peak and time of peak streamflow for applicable watersheds in the Houston metropolitan area. Lastly, analysis of the relative influence of BDF on peak streamflow is provided, and the results indicate a 0:04log10 cubic feet per second change of peak streamflow per positive unit of change in BDF. This relative change can be used to adjust peak streamflow from the method or other hydrologic methods for a given BDF to other BDF values; example computations are provided.
Johnson, S M; Christensen, A; Bellamy, G T
1976-01-01
Five children referred to a child-family intervention program wore a radio transmitter in the home during pre-intervention and termination assessments. The transmitter broadcast to a receiver-recording apparatus in the home (either activated by an interval timer at predetermined "random" times or by parents at predetermined "picked" times). "Picked" times were parent-selected situations during which problems typically occurred (e.g., bedtime). Parents activated the recorder regularly whether or not problems occurred. Child-deviant, parent-negative, and parent-commanding behaviors were significantly higher at the picked times during pretest than at random times. At posttest, behaviors in all three classes were substantially reduced at picked times, but not at random times. For individual subject data, reductions occurred in at least two of the three dependent variables for three of the five cases during random time assessments. In general, the behavioral outcome data corresponded to parent-attitude reports and parent-collected observation data.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the site-specific application programs, run timers, read inputs, drive outputs, perform self... validation process is to determine “whether the correct product was built.” Verification means the process of... established at the start of that phase. The goal of the verification process is to determine “whether the...
76 FR 19772 - Environmental Impacts Statements; Notice of Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-08
... Barker 208-735-2072. EIS No. 20110101, Final EIS, USFS, CO, Big Moose Vegetation Management Project... Salvage Project, Proposal to Treat Timer Harvest, Prescribe Fire, and Mechanical Thinning, Uinta-Wasatch... No. 20110107, Final EIS, FHWA, IL, Illinois 336 Corridor Project, (Federal Aid Primary Route 315...
Neurobehavioral Mechanisms of Temporal Processing Deficits In Parkinson’s Disease
2011-01-01
Foam padding was used to limit head motion. Auditory stimuli were delivered binaurally through a headphone that together with earplugs attenuated...core timer.’ Specifically, by the striatal beat frequency (SBF) model, Figure 5. Percent signal change in regions showing abnormal activation OFF
Profiling Participative Residents in Western Communities
ERIC Educational Resources Information Center
Matarrita-Cascante, David; Luloff, A. E.
2008-01-01
Differences between old-timers and newcomers and their effects on community social dimensions have been the object of much research. These studies have shown how extensive in-migration of people with different socioeconomic backgrounds, values, and perspectives contribute to heightened social conflict in some communities. Popular media accounts…
Unionizing in Chicago: Big Gains for Part-Timers.
ERIC Educational Resources Information Center
Laiacona, Joseph
2000-01-01
Recounts how the part-time faculty at Chicago's Columbia College (Illinois) dramatically improved salaries and gained a strong voice in college decision making through unionization. Emphasis is on the negotiation process which worked to obtain the group's goals without undermining the "rather friendly college environment." (DB)
Orion MPCV Touchdown Detection Threshold Development and Testing
NASA Technical Reports Server (NTRS)
Daum, Jared; Gay, Robert
2013-01-01
A robust method of detecting Orion Multi ]Purpose Crew Vehicle (MPCV) splashdown is necessary to ensure crew and hardware safety during descent and after touchdown. The proposed method uses a triple redundant system to inhibit Reaction Control System (RCS) thruster firings, detach parachute risers from the vehicle, and transition to the post ]landing segment of the Flight Software (FSW). The vehicle crew is the prime input for touchdown detection, followed by an autonomous FSW algorithm, and finally a strictly time based backup timer. RCS thrusters must be inhibited before submersion in water to protect against possible damage due to firing these jets under water. In addition, neglecting to declare touchdown will not allow the vehicle to transition to post ]landing activities such as activating the Crew Module Up ]righting System (CMUS), resulting in possible loss of communication and difficult recovery. A previous AIAA paper gAssessment of an Automated Touchdown Detection Algorithm for the Orion Crew Module h concluded that a strictly Inertial Measurement Unit (IMU) based detection method using an acceleration spike algorithm had the highest safety margins and shortest detection times of other methods considered. That study utilized finite element simulations of vehicle splashdown, generated by LS ]DYNA, which were expanded to a larger set of results using a Kriging surface fit. The study also used the Decelerator Systems Simulation (DSS) to generate flight dynamics during vehicle descent under parachutes. Proto ]type IMU and FSW MATLAB models provided the basis for initial algorithm development and testing. This paper documents an in ]depth trade study, using the same dynamics data and MATLAB simulations as the earlier work, to further develop the acceleration detection method. By studying the combined effects of data rate, filtering on the rotational acceleration correction, data persistence limits and values of acceleration thresholds, an optimal configuration was determined. The lever arm calculation, which removes the centripetal acceleration caused by vehicle rotation, requires that the vehicle angular acceleration be derived from vehicle body rates, necessitating the addition of a 2nd order filter to smooth the data. It was determined that using 200 Hz data directly from the vehicle IMU outperforms the 40 Hz FSW data rate. Data persistence counter values and acceleration thresholds were balanced in order to meet desired safety and performance. The algorithm proved to exhibit ample safety margin against early detection while under parachutes, and adequate performance upon vehicle splashdown. Fall times from algorithm initiation were also studied, and a backup timer length was chosen to provide a large safety margin, yet still trigger detection before CMUS inflation. This timer serves as a backup to the primary acceleration detection method. Additionally, these parameters were tested for safety on actual flight test data, demonstrating expected safety margins.
Opportunities and challenges in industrial plantation mapping in big data era
NASA Astrophysics Data System (ADS)
Dong, J.; Xiao, X.; Qin, Y.; Chen, B.; Wang, J.; Kou, W.; Zhai, D.
2017-12-01
With the increasing demand in timer, rubber, palm oil in the world market, industrial plantations have dramatically expanded, especially in Southeast Asia; which have been affecting ecosystem services and human wellbeing. However, existing efforts on plantation mapping are still limited and blocked our understanding about the magnitude of plantation expansion and their potential environmental effects. Here we would present a literature review about the existing efforts on plantation mapping based on one or multiple remote sensing sources, including rubber, oil palm, and eucalyptus plantations. The biophysical features and spectral characteristics of plantations will be introduced first, a comparison on existing algorithms in terms of different plantation types. Based on that, we proposed potential improvements in large scale plantation mapping based on the virtual constellation of multiple sensors, citizen science tools, and cloud computing technology. Based on the literature review, we discussed a series of issues for future scale operational paddy rice mapping.
Fixed-rate layered multicast congestion control
NASA Astrophysics Data System (ADS)
Bing, Zhang; Bing, Yuan; Zengji, Liu
2006-10-01
A new fixed-rate layered multicast congestion control algorithm called FLMCC is proposed. The sender of a multicast session transmits data packets at a fixed rate on each layer, while receivers each obtain different throughput by cumulatively subscribing to deferent number of layers based on their expected rates. In order to provide TCP-friendliness and estimate the expected rate accurately, a window-based mechanism implemented at receivers is presented. To achieve this, each receiver maintains a congestion window, adjusts it based on the GAIMD algorithm, and from the congestion window an expected rate is calculated. To measure RTT, a new method is presented which combines an accurate measurement with a rough estimation. A feedback suppression based on a random timer mechanism is given to avoid feedback implosion in the accurate measurement. The protocol is simple in its implementation. Simulations indicate that FLMCC shows good TCP-friendliness, responsiveness as well as intra-protocol fairness, and provides high link utilization.
Performance analysis and kernel size study of the Lynx real-time operating system
NASA Technical Reports Server (NTRS)
Liu, Yuan-Kwei; Gibson, James S.; Fernquist, Alan R.
1993-01-01
This paper analyzes the Lynx real-time operating system (LynxOS), which has been selected as the operating system for the Space Station Freedom Data Management System (DMS). The features of LynxOS are compared to other Unix-based operating system (OS). The tools for measuring the performance of LynxOS, which include a high-speed digital timer/counter board, a device driver program, and an application program, are analyzed. The timings for interrupt response, process creation and deletion, threads, semaphores, shared memory, and signals are measured. The memory size of the DMS Embedded Data Processor (EDP) is limited. Besides, virtual memory is not suitable for real-time applications because page swap timing may not be deterministic. Therefore, the DMS software, including LynxOS, has to fit in the main memory of an EDP. To reduce the LynxOS kernel size, the following steps are taken: analyzing the factors that influence the kernel size; identifying the modules of LynxOS that may not be needed in an EDP; adjusting the system parameters of LynxOS; reconfiguring the device drivers used in the LynxOS; and analyzing the symbol table. The reductions in kernel disk size, kernel memory size and total kernel size reduction from each step mentioned above are listed and analyzed.
An Electronic Timer for Measuring Spread Rates of Wildland Fires
Richard W. Blank; Albert J. Simard
1983-01-01
There are many disadvantages to current techniques for measuring the spread rate of wildland fires. This paper describes the design and use of an electronic timber that resolves most of the problems. The unit is small, lightweight, inexpensive, easy-to-assemble, self-contained, and long-running.
NASA Astrophysics Data System (ADS)
Horowitz, Paul; Hill, Winfield
2015-04-01
1. Foundations; 2. Bipolar transistors; 3. Field effect transistors; 4. Operational amplifiers; 5. Precision circuits; 6. Filters; 7. Oscillators and timers; 8. Low noise techniques and transimpedance; 9. Power regulation; 10. Digital electronics; 11. Programmable logic devices; 12. Logical interfacing; 13. Digital meets analog; 14. Computers, controllers, and data links; 15. Microcontrollers.
Instructor's Field Manual: North Carolina Outward Bound School.
ERIC Educational Resources Information Center
Outward Bound, Morganton, NC.
A supplement to the North Carolina Outward Bound School's Instructor's Handbook, this field manual presents useful, but not required, information gleaned from old timers and resource books which may enable the instructor to conduct a better course. Section one considers advantages and disadvantages and provides directions and topographical maps…
Terminal Velocity of a Shuttlecock in Vertical Fall.
ERIC Educational Resources Information Center
Peastrel, Mark; And Others
1980-01-01
Describes a straightforward vertical fall experiment using a badminton shuttlecock, a tape measure, and a millisecond timer. The effects of air resistance are important and directly measurable. The experimental data best fit a predictive model which assumes a resistive force quadratic in the instantaneous speed of the falling object. (GS)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-05
... choose the duty rates during customs entry procedures that apply to gas and electric kitchen ranges (duty... injet assemblies, vent caps, blowers, valves, gas valves, motors, fans, control boards, light indicator assemblies, timers, light indicators, capacitors, thermistors, sensors, lamps, encoder assemblies, lenses...
Programmable Logic Controllers. Teacher Edition.
ERIC Educational Resources Information Center
Rauh, Bob; Kaltwasser, Stan
These materials were developed for a seven-unit secondary or postsecondary education course on programmable logic controllers (PLCs) that treats most of the skills needed to work effectively with PLCs as programming skills. The seven units of the course cover the following topics: fundamentals of programmable logic controllers; contracts, timers,…
Measuring Time on the PET and Other Microcomputers
ERIC Educational Resources Information Center
Tesler, Larry
1978-01-01
The operation of the microcomputer requires one or more clocks or timers to measure intervals of different magnitudes. Methods are discussed for measuring time intervals on PET in hours, minutes, seconds, microseconds, miscellaneous units, and timing events on external devices. Directions are added for BASIC program applications of timing…
ERIC Educational Resources Information Center
Gramlich, Stephen Peter
2010-01-01
Open door admissions at community colleges bring returning adults, first timers, low achievers, disabled persons, and immigrants. Passing and retention rates for remedial and non-developmental math courses can be comparatively inadequate (LAVC, 2005; CCPRDC, 2000; SBCC, 2004; Seybert & Soltz, 1992; Waycaster, 2002). Mathematics achievement…
Employment in the Broadcasting Industry: 1974.
ERIC Educational Resources Information Center
Federal Communications Commission, Washington, DC. Broadcast Bureau.
Arranged alphabetically by State and by communities within each State, the 1974 report contains employment information on all braodcast units licensed by the Federal Communications Commission with more than 10 full-time employees. The report includes separate entries for the number of full-time and part-time employees, with full-timers being…
Into the Sunset: Reflections of an Interim Administrator.
ERIC Educational Resources Information Center
Marlowe, John
2000-01-01
One advantage to an interim administrative position is that the public cuts short-timers a little slack. Temporary administrators can learn on the job and become experts on specialized subjects. Personnel issues demand more time than interims possess. Such positions usually do not turn into long-term contracts. (MLH)
16 CFR 1610.5 - Test apparatus and materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
... electronic circuits, in addition to miscellaneous custom made cams and rods, shock absorbing linkages, and... burn time to 0.1 second. An electronic or mechanical timer can be used to record the burn time, and electro-mechanical devices (i.e., servo-motors, solenoids, micro-switches, and electronic circuits, in...
16 CFR 1610.5 - Test apparatus and materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
... electronic circuits, in addition to miscellaneous custom made cams and rods, shock absorbing linkages, and... burn time to 0.1 second. An electronic or mechanical timer can be used to record the burn time, and electro-mechanical devices (i.e., servo-motors, solenoids, micro-switches, and electronic circuits, in...
16 CFR § 1610.5 - Test apparatus and materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
... electronic circuits, in addition to miscellaneous custom made cams and rods, shock absorbing linkages, and... burn time to 0.1 second. An electronic or mechanical timer can be used to record the burn time, and electro-mechanical devices (i.e., servo-motors, solenoids, micro-switches, and electronic circuits, in...
Automation of extrusion of porous cable products based on a digital controller
NASA Astrophysics Data System (ADS)
Chostkovskii, B. K.; Mitroshin, V. N.
2017-07-01
This paper presents a new approach to designing an automated system for monitoring and controlling the process of applying porous insulation material on a conductive cable core, which is based on using structurally and parametrically optimized digital controllers of an arbitrary order instead of calculating typical PID controllers using known methods. The digital controller is clocked by signals from the clock length sensor of a measuring wheel, instead of a timer signal, and this provides the robust properties of the system with respect to the changing insulation speed. Digital controller parameters are tuned to provide the operating parameters of the manufactured cable using a simulation model of stochastic extrusion and are minimized by moving a regular simplex in the parameter space of the tuned controller.
Nutrient-driven O-GlcNAc in proteostasis and neurodegeneration.
Akan, Ilhan; Olivier-Van Stichelen, Stephanie; Bond, Michelle R; Hanover, John A
2018-01-01
Proteostasis is essential in the mammalian brain where post-mitotic cells must function for decades to maintain synaptic contacts and memory. The brain is dependent on glucose and other metabolites for proper function and is spared from metabolic deficits even during starvation. In this review, we outline how the nutrient-sensitive nucleocytoplasmic post-translational modification O-linked N-acetylglucosamine (O-GlcNAc) regulates protein homeostasis. The O-GlcNAc modification is highly abundant in the mammalian brain and has been linked to proteopathies, including neurodegenerative diseases such as Alzheimer's, Parkinson's, and Huntington's. C. elegans, Drosophila, and mouse models harboring O-GlcNAc transferase- and O-GlcNAcase-knockout alleles have helped define the role O-GlcNAc plays in development as well as age-associated neurodegenerative disease. These enzymes add and remove the single monosaccharide from protein serine and threonine residues, respectively. Blocking O-GlcNAc cycling is detrimental to mammalian brain development and interferes with neurogenesis, neural migration, and proteostasis. Findings in C. elegans and Drosophila model systems indicate that the dynamic turnover of O-GlcNAc is critical for maintaining levels of key transcriptional regulators responsible for neurodevelopment cell fate decisions. In addition, pathways of autophagy and proteasomal degradation depend on a transcriptional network that is also reliant on O-GlcNAc cycling. Like the quality control system in the endoplasmic reticulum which uses a 'mannose timer' to monitor protein folding, we propose that cytoplasmic proteostasis relies on an 'O-GlcNAc timer' to help regulate the lifetime and fate of nuclear and cytoplasmic proteins. O-GlcNAc-dependent developmental alterations impact metabolism and growth of the developing mouse embryo and persist into adulthood. Brain-selective knockout mouse models will be an important tool for understanding the role of O-GlcNAc in the physiology of the brain and its susceptibility to neurodegenerative injury. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Instrumentation for Examining Microbial Response to Changes In Environmental Pressures
NASA Astrophysics Data System (ADS)
Blaich, J.; Storrs, A.; Wang, J.; Ouandji, C.; Arismendi, D.; Hernandez, J.; Sardesh, N.; Ibanez, C. R.; Owyang, S.; Gentry, D.
2016-12-01
The Automated Adaptive Directed Evolution Chamber (AADEC) is a device that allows operators to generate a micro-scale analog of real world systems that can be used to model the local-scale effects of climate change on microbial ecosystems. The AADEC uses an artificial environment to expose cultures of micro-organisms to environmental pressures, such as UV-C radiation, chemical toxins, and temperature. The AADEC autonomously exposes micro-organisms to slection pressures. This improves upon standard manual laboratory techniques: the process can take place over a longer period of time, involve more stressors, implement real-time adjustments based on the state of the population, and minimize the risk of contamination. We currently use UV-C radiation as the main selection pressure, UV-C is well studied both for its cell and DNA damaging effects as a type of selection pressure and for its related effectiveness as a mutagen; having these functions united makes it a good choice for a proof of concept. The AADEC roadmap includes expansion to different selection pressures, including heavy metal toxicity, temperature, and other forms of radiation. The AADEC uses closed-loop control to feedback the current state of the culture to the AADEC controller that modifies selection pressure intensity during experimentation, in this case culture density and growth rate. Culture density and growth rate are determined by measuring the optical density of the culture using 600 nm light. An array of 600 nm LEDs illuminate the culture and photodiodes are used to measure the shadow on the opposite side of the chamber. Previous experiments showed that we can produce a million fold increase to UV-C radiation over seven iterations. The most recent implements a microfluidic system that can expose cultures to multiple different selection pressures, perform non-survival based selection, and autonomously perform hundreds of exposure cycles. A scalable pump system gives the ability to pump in various different growth media to individual cultures and introduce chemical toxins during experimentation; AADEC can perform freeze and thaw cycles. We improved our baseline characterization by building a custom UV-C exposure hood, a shutter operates on a preset timer allowing the user to set exposure intensity consistently for multiple iterations.
Moisture content measurement in paddy
NASA Astrophysics Data System (ADS)
Klomklao, P.; Kuntinugunetanon, S.; Wongkokua, W.
2017-09-01
Moisture content is an important quantity for agriculture product, especially in paddy. In principle, the moisture content can be measured by a gravimetric method which is a direct method. However, the gravimetric method is time-consuming. There are indirect methods such as resistance and capacitance methods. In this work, we developed an indirect method based on a 555 integrated circuit timer. The moisture content sensor was capacitive parallel plates using the dielectric constant property of the moisture. The instrument generated the output frequency that depended on the capacitance of the sensor. We fitted a linear relation between periods and moisture contents. The measurement results have a standard uncertainty of 1.23 % of the moisture content in the range of 14 % to 20 %.
Magnesium Object Manager Sandbox, A More Effective Sandbox Method for Windows 7
2012-03-01
keys, synchronization primitives , etc.). The object body is specific to, and the same for, each object type; it contains information common to each...the Object Directory Specific Rights Synchronization Object (Event, Mutex, Semaphore , Timer) Synchronization objects allow multiple threads to... Synchronization Object Specific Rights . . . . . . . . . . . . . . . . . . . . . 19 2.5 File Object Specific Rights
Integrating Speaking Skills into the Curriculum.
ERIC Educational Resources Information Center
Nugent, Susan Monroe, Ed.
1986-01-01
Stressing the importance of incorporating speech skills throughout the curriculum, the articles in this journal provide ideas for developing speaking skills in all subjects and at all levels. The titles of the articles and their authors include the following: (1) "Speaking Skills: A Few Tips from an Old Timer" (Geoffrey R. Butler); (2)…
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
10 CFR 35.2645 - Records of periodic spot-checks for gamma stereotactic radiosurgery units.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Records of periodic spot-checks for gamma stereotactic... MATERIAL Records § 35.2645 Records of periodic spot-checks for gamma stereotactic radiosurgery units. (a) A... and intercom systems, timer termination, treatment table retraction mechanism, and stereotactic frames...
36. VIEW EAST OF WASTE HEAT RECOVERY SYSTEM IN BUILDING ...
36. VIEW EAST OF WASTE HEAT RECOVERY SYSTEM IN BUILDING 43A; THIS WAS PART OF A SYSTEM WHICH PROVIDED HOT WATER FOR OFFICE AND FACTORY BUILDING HEATING IN THE WEST PLANT; NOTE FACTORY WHISTLE TIMER ON TOP OF HEAT EXCHANGER - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
Characterization of Toxicologically Relevant Compounds From Diesel Emissions: Phase II
2004-03-01
eight-channel timer board that synchronizes with the engine crankshaft and camshaft pulses for activation of the fuel injectors. Each cylinder of the...Musculus M. P., Dec J. E., Tree D. R. SAE Paper 2002-01-0889. 57 11. Flame Lift-Off on Direct-Injection Diesel Fuel Jets: Oxygen Concentration Effects
30 CFR 18.65 - Flame test of hose.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Inspections and Tests § 18.65 Flame... variable-speed electric fan and an ASME flow nozzle (16-81/2 inches reduction) to attain constant air velocities at any speed between 50-500 feet a minute. (4) An electric timer or stopwatch to measure the...
Numerical Integration with Graphical Processing Unit for QKD Simulation
2014-03-27
Windows system application programming interface (API) timer. The problem sizes studied produce speedups greater than 60x on the NVIDIA Tesla C2075...13 2.3.3 CUDA API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.3.4 CUDA and NVIDIA GPU Hardware...Theoretical Floating-Point Operations per Second for Intel CPUs and NVIDIA GPUs [3
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-08
... Proposal Regarding Quote Mitigation November 2, 2012. Pursuant to Section 19(b)(1) under the Securities... (Quote Mitigation) and refine the current quote mitigation strategy for its options trading facility, BOX Market LLC (``BOX'') by replacing the current quote mitigation rule with a ``holdback timer'' mechanism...
The Use of Opto-Electronics in Viscometry.
ERIC Educational Resources Information Center
Mazza, R. J.; Washbourn, D. H.
1982-01-01
Describes a semi-automatic viscometer which incorporates a microprocessor system and uses optoelectronics to detect flow of liquid through the capillary, flow time being displayed on a timer with accuracy of 0.01 second. The system could be made fully automatic with an additional microprocessor circuit and inclusion of a pump. (Author/JN)
FIRST FLOOR, A view looking north at the controls for ...
FIRST FLOOR, A view looking north at the controls for the Stokes Press along the wall outside Room 136. These controls include a thermometer, timer and pressure switches, and a buss bar used for static electricity control - Department of Energy, Mound Facility, Isolated Building (I Building), One Mound Road, Miamisburg, Montgomery County, OH
Norman G. Hicks; Michael A. Menzel; Joshua Laerm
1998-01-01
We compared inferred activity patterns of two syntopic rodents, Peromyscus Zeucopus and P. maniculatus, in western North Carolina. Activity patterns were derived from capture-frequency data obtained from Sherman live-traps equipped with digital timers following different trapping protocols. We tested the hypothesis that no...
ERIC Educational Resources Information Center
Oguntoyinbo, Lekan
2011-01-01
For eight decades, students at Southeast Missouri State University, a mid-sized college located on the banks of the Mississippi River in rural, conservative Cape Girardeau, had proudly rooted for its sports teams, the Indians. The old-timers said the name was adopted in the mid-1920s to honor the legacy of American Indians and their warrior…
30 CFR 35.20 - Autogenous-ignition temperature test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... timer shall be stopped. The test flask shall then be flushed well with clean dry air and, after a lapse... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Autogenous-ignition temperature test. 35.20..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20...
Timber resource of Missouri's Northwestern Ozarks, 1972.
Alexander Vasilevsky; Burton L. Essex
1974-01-01
The third timber inventory of Missouri's Northwestern Ozarks Forest Survey Unit shows substantial gains in both growing-stock and sawtimber volumes between 1959 and 1972. The area of commercial forests declined during the same period. Presented are highlights and statistics on forest area and timer volume, growth, mortality, ownership and use in 1972.
NASA Astrophysics Data System (ADS)
Bigu, J.; Elliott, J.
1994-05-01
An instrument has been developed for continuous monitoring of 220Rn. The method of data analysis is based on delayed coincidences between 220Rn and 216Po. The instrument basically consists of a scaler equipped with a photomultiplier tube (PMT) to which a scintillation cell (SC) of the flow through type is optically coupled. The scaler is equipped with a pulse output (P/O) port which provides a TTL pulse, +5 V in amplitude and 5 to 10 μs duration for each nuclear event recorded by the SC and its associated electronic circuitry. The P/O port is connected to a 32 bit counter/timer unit operating at 1 MHz which records and stores the time of arrival of pulses. For laboratory use, the counter/timer is connected to the serial port of a laptop PC. However, for field applications, where space and weight pose severe practical limitations, the PC is substituted by an expanded counter/timer unit which incorporates a muprocessor for data analysis, a LCD for data display, and a keypad to key in function instructions. Furthermore, some additional hardware permits the measurement of 220Rn flux density, J( 220Rn) , from soils and other materials. Because total α-particle count, as well as delayed (α - α) coincidence rates are recorded in two separate channels, the method permits the measurement of 222Rn in addition to 220Rn. The method is particularly useful for low concentration levels. The sensitivity of the method primarily depends on the volume of the SC. For a low volume SC (˜0.16 l), a sensitivity of 0.2 h -1/Bq m -3 for 220Rn and 1.4 h -1/Bq m -3 for 222Rn are readily attainable. For a large volume (1.5 l) SC (external PMT used), the sensitivity for 220Rn is ≥ 1.5 h -1/Bq m -3, depending on the SC design and the operating sampling flowrate. (Note: h -1 stands for counts per hour). The above instrument has been used extensively at the National Radon/Thoron Test Facility (NRTTF) of the Elliot Lake Laboratory for routine monitoring of 220Rn levels since 1992. It has also been used for outdoor and indoor 220Rn measurements, as well as for the determination of J( 220Rn) from earthen materials and the like.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pletnev, Sergei; Subach, Fedor V.; Dauter, Zbigniew
2010-03-12
Fast-FT is a fluorescent timer (FT) engineered from DsRed-like fluorescent protein mCherry. Crystal structures of Fast-FT (chromophore Met66-Tyr67-Gly68) and its precursor with blocked blue-to-red conversion Blue102 (chromophore Leu66-Tyr67-Gly68) have been determined at the resolution of 1.15 {angstrom} and 1.81 {angstrom}, respectively. Structural data suggest that blue-to-red conversion, taking place in Fast-FT and in related FTs, is associated with the oxidation of C{alpha}2-C{beta}2 bond of Tyr67. Site directed mutagenesis revealed a crucial role of Arg70 and Tyr83 in the delayed oxidation of C{alpha}2-C{beta}2 bond, introducing the timing factor in maturation of the timer. Substitutions Ser217Ala and Ser217Cys in Fast-FT substantially slowmore » down formation of an intermediate blue chromophore but do not affect much blue-to-red conversion, whereas mutations Arg70Lys or Trp83Leu, having little effect on the blue chromophore formation rate, markedly accelerates formation of the red chromophore. The chromophore of FTs adopts a cis-conformation stabilized by a hydrogen bond between its phenolate oxygen and the side chain hydroxyl of Ser146. In Blue102, a bulky side chain of Ile146 precludes the chromophore from adopting a 'cis-like' conformation, blocking its blue-to-red conversion. Both Fast-FT and Blue102 structures revealed hydrolytic degradation of the chromophores. In Fast-FT, chromophore-forming Met66 residue is eliminated from the polypeptide chain, whereas Leu66 in Blue102 is cleaved out from the chromophore, decarboxylated and remains attached to the preceding Phe65. Hydrolysis of the chromophore competes with chromophore maturation and is driven by the same residues that participate in chromophore maturation.« less
The fast and the slow of skilled bimanual rhythm production: parallel versus integrated timing.
Krampe, R T; Kliegl, R; Mayr, U; Engbert, R; Vorberg, D
2000-02-01
Professional pianists performed 2 bimanual rhythms at a wide range of different tempos. The polyrhythmic task required the combination of 2 isochronous sequences (3 against 4) between the hands; in the syncopated rhythm task successive keystrokes formed intervals of identical (isochronous) durations. At slower tempos, pianists relied on integrated timing control merging successive intervals between the hands into a common reference frame. A timer-motor model is proposed based on the concepts of rate fluctuation and the distinction between target specification and timekeeper execution processes as a quantitative account of performance at slow tempos. At rapid rates expert pianists used hand-independent, parallel timing control. In alternative to a model based on a single central clock, findings support a model of flexible control structures with multiple timekeepers that can work in parallel to accommodate specific task constraints.
NASA Technical Reports Server (NTRS)
Nichols, J. D.; Gialdini, M.; Jaakkola, S.
1974-01-01
A quasi-operational study demonstrating that a timber inventory based on manual and automated analysis of ERTS-1, supporting aircraft data and ground data was made using multistage sampling techniques. The inventory proved to be a timely, cost effective alternative to conventional timber inventory techniques. The timber volume on the Quincy Ranger District of the Plumas National Forest was estimated to be 2.44 billion board feet with a sampling error of 8.2 percent. Costs per acre for the inventory procedure at 1.1 cent/acre compared favorably with the costs of a conventional inventory at 25 cents/acre. A point-by-point comparison of CALSCAN-classified ERTS data with human-interpreted low altitude photo plots indicated no significant differences in the overall classification accuracies.
Time-Lapse Motion Picture Technique Applied to the Study of Geological Processes.
Miller, R D; Crandell, D R
1959-09-25
Light-weight, battery-operated timers were built and coupled to 16-mm motion-picture cameras having apertures controlled by photoelectric cells. The cameras were placed adjacent to Emmons Glacier on Mount Rainier. The film obtained confirms the view that exterior time-lapse photography can be applied to the study of slow-acting geologic processes.
Sundown Town to "Little Mexico": Old-Timers and Newcomers in an American Small Town
ERIC Educational Resources Information Center
McConnell, Eileen Diaz; Miraftab, Faranak
2009-01-01
For more than a century, communities across the United States legally employed strategies to create and maintain racial divides. One particularly widespread and effective practice was that of "sundown towns," which signaled to African Americans and others that they were not welcome within the city limits after dark. Though nearly 1,000…
Effects of Scheduling Perceptions on Attitudes and Mobility in Different Part-Time Employee Types
ERIC Educational Resources Information Center
Wittmer, Jenell L. S.; Martin, James E.
2011-01-01
Recent research supports the existence of a typology of part-time employees with demographic and behavioral differences. This research suggests that part-timers should not be viewed as one homogenous group and that certain part-time employee groups have fixed external role attachments, while others have more flexible attachments. Applying the…
A timed solenoid injector for flow analysis.
Rothwell, S D; Woolf, A A
1985-05-01
Samples can be reproducibly injected into flow-streams by timed switching of a sample stream with a miniature solenoid valve and timer circuit. The device is simpler to assemble and use than the standard rotary valve and a direct comparison under the same operating conditions shows that the solenoid valve is an adequate replacement for the rotary valve.
Time's Up, Turkey--Pop-Up Thermometers
ERIC Educational Resources Information Center
Moyer, Richard; Everett, Susan
2009-01-01
Meat thermometers can be awkward to use in terms of placement and avoidance of bones. Because of these problems, each year 30 million Thanksgiving turkeys have a built-in thermometer that pops up when the turkey is properly cooked. Turkey timers are an example of how engineering solved a common, everyday problem. The following 5E learning cycle…
A Comparison of the Effects of Brief Rules, a Timer, and Preferred Toys on Self-Control
ERIC Educational Resources Information Center
Newquist, Matthew H.; Dozier, Claudia L.; Neidert, Pamela L.
2012-01-01
Some children make impulsive choices (i.e., choose a small but immediate reinforcer over a large but delayed reinforcer). Previous research has shown that delay fading, providing an alternative activity during the delay, teaching participants to repeat a rule during the delay, combining delay fading with an alternative activity, and combining…
ROMPS critical design review data package
NASA Technical Reports Server (NTRS)
Dobbs, M. E.
1992-01-01
The design elements of the Robot-Operated Material Processing in Space (ROMPS) system are described in outline and graphical form. The following subsystems/topics are addressed: servo system, testbed and simulation results, System V Controller, robot module, furnace module, SCL experiment supervisor and script sample processing control, battery system, watchdog timers, mechanical/thermal considerations, and fault conditions and recovery.
Sonawane, A U; Singh, Meghraj; Sunil Kumar, J V K; Kulkarni, Arti; Shirva, V K; Pradhan, A S
2010-10-01
We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements stipulated by the national regulatory body. The audit mainly covered accuracy check of accelerating potential (kVp), linearity of tube current (mA station) and timer, congruence of radiation and optical field, and total filtration; in addition, we also reviewed medical X-ray diagnostic installations with reference to room layout of X-ray machines and conduct of radiological protection survey. A QA kit consisting of a kVp Test-O-Meter (ToM) (Model RAD/FLU-9001), dose Test-O-Meter (ToM) (Model 6001), ionization chamber-based radiation survey meter model Gun Monitor and other standard accessories were used for the required measurements. The important areas where there was noncompliance with the national safety code were: inaccuracy of kVp calibration (23%), lack of congruence of radiation and optical field (23%), nonlinearity of mA station (16%) and timer (9%), improper collimator/diaphragm (19.6%), faulty adjustor knob for alignment of field size (4%), nonavailability of warning light (red light) at the entrance of the X-ray room (29%), and use of mobile protective barriers without lead glass viewing window (14%). The present study on the radiological safety status of diagnostic X-ray installations may be a reasonably good representation of the situation in the country as a whole. The study contributes significantly to the improvement of radiological safety by the way of the steps already taken and by providing a vital feed back to the national regulatory body.
Automatic fixation facility for plant seedlings in the TEXUS Sounding Rocket Programme.
Tewinkel, M; Burfeindt, J; Rank, P; Volkmann, D
1991-10-01
Automatic chemical fixation of plant seedlings within a 6 min period of reduced gravity (10(-4)g) was performed on three ballistic rocket flights provided by the German Sounding Rocket Programme TEXUS (Technologische Experimente unter Schwerelosigkeit = Technological Experiments in Microgravity). The described TEXUS experiment module consists of a standard experiment housing with batteries, cooling and heating systems, timer, and a data recording unit. Typically, 60 min before launch an experiment plug-in unit containing chambers with the plant material, the fixation system, and the temperature sensors is installed into the module which is already integrated in the payload section of the sounding rocket (late access). During the ballistic flight plant chambers are rapidly filled at pre-selected instants to preserve the cell structure of gravity sensing cells. After landing the plant material is processed for transmission electron microscopy. Up to now three experiments were successfully performed with cress roots (Lepidium sativum L.). Detailed improvements resulted in an automatic fixation facility which in principle can be used in unmanned missions.
Ferrin, Michael A; Subramaniam, Arvind R
2017-01-01
Ribosome stalling on mRNAs can decrease protein expression. To decipher ribosome kinetics at stall sites, we induced ribosome stalling at specific codons by starving the bacterium Escherichia coli for the cognate amino acid. We measured protein synthesis rates from a reporter library of over 100 variants that encoded systematic perturbations of translation initiation rate, the number of stall sites, and the distance between stall sites. Our measurements are quantitatively inconsistent with two widely-used kinetic models for stalled ribosomes: ribosome traffic jams that block initiation, and abortive (premature) termination of stalled ribosomes. Rather, our measurements support a model in which collision with a trailing ribosome causes abortive termination of the stalled ribosome. In our computational analysis, ribosome collisions selectively stimulate abortive termination without fine-tuning of kinetic rate parameters at ribosome stall sites. We propose that ribosome collisions serve as a robust timer for translational quality control pathways to recognize stalled ribosomes. DOI: http://dx.doi.org/10.7554/eLife.23629.001 PMID:28498106
Arduino based radiation survey meter
NASA Astrophysics Data System (ADS)
Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Muzakkir, Amir; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee
2016-01-01
This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr-1). Conversion factor (CF) value for conversion of CPM to μSvhr-1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.
Longevity and survival curves of Rhinella icterica (Anura, Bufonidae) under laboratory conditions.
Lima, M S C S; Pederassi, J; Souza, C A S
2014-05-01
Life tables and survival curves of tadpoles from Rhinella icterica species were studied in the laboratory, under abiotic conditions controlled by a purification filter, a timer and a chiller. The survival curve for larval stage confirms a great mortality trend in the initial stages, which decreases when reaching the mature morphological condition (r = -0.94). Stages 37, 38, 39, 40 and 41 showed gradual values for their age structures, while stages 42, 43 and 44 presented high variations. Based on the results under laboratory conditions, it can be concluded that the maturity of R. icterica tadpoles development between 37 and 44 stages has a negative correlation and their predicted life expectancy is a logarithmic growth curve (y=-761.96Ln(x)+5298.5).
Rapid and precise determination of ATP using a modified photometer
Shultz, David J.; Stephens, Doyle W.
1980-01-01
An inexpensive delay timer was designed to modify a commercially available ATP photometer which allows a disposable tip pipette to be used for injecting either enzyme or sample into the reaction cuvette. The disposable tip pipette is as precise and accurate as a fixed-needle syringe but eliminates the problem of sample contamination and decreases analytical time. (USGS)
The Light-Emitting Diode as a Light Detector
ERIC Educational Resources Information Center
Baird, William H.; Hack, W. Nathan; Tran, Kiet; Vira, Zeeshan; Pickett, Matthew
2011-01-01
A light-emitting diode (LED) and operational amplifier can be used as an affordable method to provide a digital output indicating detection of an intense light source such as a laser beam or high-output LED. When coupled with a microcontroller, the combination can be used as a multiple photogate and timer for under $50. A similar circuit is used…
A Practical Example Aiding Understanding Momentum in 1D: The Water Gun Experiment
ERIC Educational Resources Information Center
MacLeod, Katarin
2007-01-01
The law of conservation of momentum is one that students often have difficulties understanding. This experiment allows students to use childhood toys to examine and calculate the muzzle velocity of their favourite water gun by using an air track, a spark timer or data logger and the law of conservation of momentum in a one-dimensional case, a…
Primary Care Sports Medicine: A Full-Timer's Perspective.
ERIC Educational Resources Information Center
Moats, William E.
1988-01-01
This article describes the history and structure of a sports medicine facility, the patient care services it offers, and the types of injuries treated at the center. Opportunities and potentials for physicians who wish to enter the field of sports medicine on a full-time basis are described, as are steps to take to prepare to do so. (Author/JL)
The south's timer export potential
James E. Granskog
1986-01-01
Exports of southern wood products have bccil dcclirling since 1980, following a dramatic rise during the 1970s. The value of these exports rose from near the $50 million level in the early 1970s to almost $500 million in 1980, but has dropped by more than a third since then. Now, however, changing monetary conditions appear to be turning the trend upward again....
Relationship between stress wave velocities of green and dry veneer
Brian K. Brashaw; Xiping Wang; Robert J. Ross; Roy F. Pellerin
2004-01-01
This paper evaluates the relationship between the stress wave velocities of green and dry southern pine and Douglas-fir veneers. A commercial stress wave timer and a laboratory signal analysis system were used to measure the transit time required for an induced stress wave to travel the longitudinal length of each veneer. Stress wave transit times were measured in the...
Impact of Inclusion or Exclusion of Repeaters on Test Equating
ERIC Educational Resources Information Center
Puhan, Gautam
2011-01-01
This study examined the effect of including or excluding repeaters on the equating process and results. New forms of two tests were equated to their respective old forms using either all examinees or only the first timer examinees in the new form sample. Results showed that for both tests used in this study, including or excluding repeaters in the…
ERIC Educational Resources Information Center
Casini, Laurence; Burle, Boris; Nguyen, Noel
2009-01-01
Time is essential to speech. The duration of speech segments plays a critical role in the perceptual identification of these segments, and therefore in that of spoken words. Here, using a French word identification task, we show that vowels are perceived as shorter when attention is divided between two tasks, as compared to a single task control…
The Soviet Union: Yesterday, Today, Tomorrow. A Colloquy of American Long-Timers in Moscow
1975-04-01
the Third World in its confrontations with the United States. KOTLER : Much of the discussion that we’ve been having relates to a Phrase that I...Then what do we do? SCOTT: We: had a meeting last week with a guy named Philip Handler. He is the President of the National Academy of Sciences
The Richness of Language and the Poverty of Part-Timers: Impact and Invisibility.
ERIC Educational Resources Information Center
Wallace, M. Elizabeth
The difficulties experienced by part-time faculty members are discussed, and some benefits of part-time teaching are identified. Among the problems faced by part-time staff are per-course salaries, lack of college-paid benefits, job insecurity, and invisibility on campus. If the part-time teaching position is a primary source of income and career…
Working with Lecturers and Part-Time Faculty: A Case Study of Russian in the National Capital Area.
ERIC Educational Resources Information Center
Robin, Richard
This chapter examines the specific issues and problems of hiring part-time instructors for foreign language courses. Specifically, it discusses the part-time situation for teaching Russian in the Washington, DC area. It looks first at the major factors involved in hiring part-timers, particularly compared to graduate teaching assistants, commonly…
Becoming "Local" in ESL: Racism as Resource in a Hawai'i Public High School
ERIC Educational Resources Information Center
Talmy, Steven
2010-01-01
Drawn from a 2.5 year critical ethnography in the ESL program of a Hawai'i public high school (Tradewinds High), this article examines racializing and racist conduct directed at Micronesian students by a group of old-timer ESL students, primarily of East/Southeast Asian inheritance. Racialization and racism directed at Micronesians positioned them…
NASA Technical Reports Server (NTRS)
Williams, James P.; Martin, Keith D.; Thomas, Justin R.; Caro, Samuel
2010-01-01
The International Space Station (ISS) Solar Array Management (SAM) software toolset provides the capabilities necessary to operate a spacecraft with complex solar array constraints. It monitors spacecraft telemetry and provides interpretations of solar array constraint data in an intuitive manner. The toolset provides extensive situational awareness to ensure mission success by analyzing power generation needs, array motion constraints, and structural loading situations. The software suite consists of several components including samCS (constraint set selector), samShadyTimers (array shadowing timers), samWin (visualization GUI), samLock (array motion constraint computation), and samJet (attitude control system configuration selector). It provides high availability and uptime for extended and continuous mission support. It is able to support two-degrees-of-freedom (DOF) array positioning and supports up to ten simultaneous constraints with intuitive 1D and 2D decision support visualizations of constraint data. Display synchronization is enabled across a networked control center and multiple methods for constraint data interpolation are supported. Use of this software toolset increases flight safety, reduces mission support effort, optimizes solar array operation for achieving mission goals, and has run for weeks at a time without issues. The SAM toolset is currently used in ISS real-time mission operations.
NASA Astrophysics Data System (ADS)
2013-03-01
WE RECOMMEND Locktronics Electronics, Magnestism and Materials Unit Robust, reliable and proven classroom kit The Million Death Quake: the Science of Predicting the Earth's Deadliest Natural Disaster Accessible and well-written book covers everything you might (and perhaps should) want to know about earthquakes WORTH A LOOK Time Trial R/C Race Track Timer Fun kit for use with toy cars but little flexibility for other uses A Universe From Nothing: Why There is Something Rather Than Nothing Up-to-date account of cosmology explains very well but becomes polemical and loses focus Nuclear physics and technology—inside the atom IOP report useful for students considering a career in physics Particle Physics: A Very Short Introduction Passages of good writing undermined by editing as the structure and illustrations disappoint Radiation and You Report is an interesting insight into radiation information from 25 years back, but some errors and a slow start let it down WEB WATCH App that aids star identification is highly recommended and videos for students and teachers also make the grade
Zheng, Wendong; Zeng, Pingping
2016-01-01
ABSTRACT Most of the empirical studies on stochastic volatility dynamics favour the 3/2 specification over the square-root (CIR) process in the Heston model. In the context of option pricing, the 3/2 stochastic volatility model (SVM) is reported to be able to capture the volatility skew evolution better than the Heston model. In this article, we make a thorough investigation on the analytic tractability of the 3/2 SVM by proposing a closed-form formula for the partial transform of the triple joint transition density which stand for the log asset price, the quadratic variation (continuous realized variance) and the instantaneous variance, respectively. Two distinct formulations are provided for deriving the main result. The closed-form partial transform enables us to deduce a variety of marginal partial transforms and characteristic functions and plays a crucial role in pricing discretely sampled variance derivatives and exotic options that depend on both the asset price and quadratic variation. Various applications and numerical examples on pricing moment swaps and timer options with discrete monitoring feature are given to demonstrate the versatility of the partial transform under the 3/2 model. PMID:28706460
Robert H. McAlister
1980-01-01
Dry volume yields and standard grades of veneer are given for yellow-poplar, sweetgum, and white oak by tree diameter and location within the stem. Results show that the typical stands of mixed southern pine and hardwood timer yield enough veneer to utilize almost 90 percent of the stand volume in the production of COM-PLY lumber and panels
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-64724; File No. SR-NASDAQ-2011-085] Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate Effectiveness of Proposed Rule Change To Adopt a Market Order Timer June 22, 2011. Pursuant to Section 19(b)(1) of the Securities Exchange Act of 1934 (``Act''),\\1\\ and...
ROMPS critical design review. Volume 1: Hardware
NASA Technical Reports Server (NTRS)
Dobbs, M. E.
1992-01-01
Topics concerning the Robot-Operated Material Processing in Space (ROMPS) Program are presented in viewgraph form and include the following: a systems overview; servocontrol and servomechanisms; testbed and simulation results; system V controller; robot module; furnace module; SCL experiment supervisor; SCL script sample processing control; SCL experiment supervisor fault handling; block diagrams; hitchhiker interfaces; battery systems; watchdog timers; mechanical/thermal systems; and fault conditions and recovery.
Effective Leadership: Perceptions of Newcomers and Old Timers in the Navy
1974-10-01
and subordinate performance and satisfaction as the dependent variable criteria. Korman divides his results according to the source of the criteria...generalization. Several theorists have postulated that leaders and sub- ordinates should have shared expectations if performance and satisfaction ...Technical Report • PERFORMING ORG. REPORT NUMBER 7. AUTHORr«; Stanley M. Nealey George C. Thornton, III I. CONTRACT OR GRANT NUMBERC«) N00014-73
1985-09-01
Amonium Nitrate 301 Alkaline rust 104 Cold rinse remover 105...LABORATORY IAFESC/RDVW I IDTIC SLECTE DECO 3 WE SEPTEMBER 1985 D FINAL REPORT JANUARY 1985 -JUNE 1985 J APPROVED FOR PUBLIC RELEASE: DISTRIBUTION UNLIMITED...VIRGINIA 22314 .4" -5 . • " - ’ -. "." . . ."" L. . " -’ ’- ", "" -" " ". . . * V . . .," S " , ." ,. a V ’ *" " UNCLASSIFIEDA D ScURITY
NASA Astrophysics Data System (ADS)
Nowakowski, C.; Friedman, D.; Green, P.
2001-10-01
The purpose of the current experiment is to provide a preliminary driving simulator assessment of several hands-free design solutions with regard to the task of answering the phone while driving. Specifically, the following questions were examined: (1) Does the location of a caller ID display and the phone buttons (two HUD (Head Up Display) locations vs. phone cradle) affect either the time to answer the phone or driving performance; (2) Does the presence or absence of a ring affect either the time to answer the phone or driving performance; (3) Does increased driving workload (visual demand) affect either the time to answer the phone or driving performance; (4) What were the initial driver reactions to a HUD-based call timer.
Remote platform power conserving system
NASA Technical Reports Server (NTRS)
Kurvin, C. W. (Inventor)
1974-01-01
A system is described where an unattended receiver and transmitter equipped data collection platform is interrogated by a substantially polar orbiting satellite. The method and apparatus involve physically representing the orbit of the satellite and the spin of the planetary body with timers, and using these representations to turn on the platform's receiver only when the satellite should be in radio range of the platform, whereby battery power at the platform is conserved.
Recent changes in the size of southern forest enterprises: A survivor analysis
James E. Granskog
1989-01-01
Over the decade from 1976 to 1986, the trend among southern enterprises that process softwood timer has been to build larger operations to reduce unit cots. Minimum efficient plant size, as determined by survivor analysis, has increased from 1,000 to 1,500 tons per day from pulpmills, 100 to 250 million square feeet per year for softwood plywood plants, and 20 to 50...
Landslide: Systematic Dynamic Race Detection in Kernel Space
2012-05-01
schedule_in_flight← true; CAUSE_TIMER_INTERRUPT(); end if end function Thread Scheduling Finally, the Landslide scheduler is responsible for managing ...child process vanish() simultaneously. • double_wait: Tests interactions of multiple waiters on a single child. • double_thread_fork: Tests for...conditions using Landslide. We describe them here. • Too many waiters allowed. Using the double_wait test case, Group 1 found a bug in which more threads
Synthesis and Reactivity of 1-Methyl-e-Ethynylpyridinium Triflate
1992-05-15
Approved for public release, distribution unlimited 13. ABSTRACT (Maximum 200 words) 1- Methyl -4-ethynylpyridiniurn triflate has been prepared by treatment of... treatment of 4-ethynylpyrdine with methyl tinflase in methylene chloride. I his new native acetylenic monomer timerized to tris. 1.3.5-( I...described their conversion to polymers with regular structure.8.9 Using the analogy to vinylpyridine, we examined reactions of 1 with triflic acid and methyl
Experimental investigation of stress wave propagation in standing trees
Houjiang Zhang; Xiping Wang; Juan Su
2011-01-01
The objective of this study was to investigate how a stress wave travels in a standing tree as it is introduced into the tree trunk through a mechanical impact. A series of stress wave time-of-flight (TOF) data were obtained from three freshly-cut red pine (Pinus resinosa Ait.) logs by means of a two-probe stress wave timer. Two-dimensional (2D) and three-dimensional (...
Heyd, J.W.
1959-07-14
An electronic circuit is described for precisely controlling the power delivered to a load from an a-c source, and is particularly useful as a welder timer. The power is delivered in uniform pulses, produced by a thyratron, the number of pulses being controlled by a one-shot multivibrator. The starting pulse is synchronized with the a-c line frequency so that each multivlbrator cycle begins at about the same point in the a-c cycle.
ERIC Educational Resources Information Center
Jacoby, Dan
2005-01-01
According to data derived from a community-college survey in the state of Washington, the majority of part-time faculty prefer full-time work. Using a logit regression analysis, the study reported in this paper suggests that typical part-timers enter their part-time teaching situations with the intent of becoming full-time, but gradually become…
An adaptive molecular timer in p53-meidated cell fate decision
NASA Astrophysics Data System (ADS)
Zhang, Xiao-Peng; Wang, Ping; Liu, Feng; Wang, Wei
The tumor suppressor p53 decides cellular outcomes in the DNA damage response. It is intriguing to explore the link between p53 dynamics and cell fates. We developed a theoretical model of p53 signaling network to clarify the mechanism of cell fate decision mediated by its dynamics. We found that the interplay between p53-Mdm2 negative feedback loop and p53-PTEN-Mdm2 positive feedback loop shapes p53 dynamics. Depending on the intensity of DNA damage, p53 shows three modes of dynamics: persistent pulses, two-phase dynamics with pulses followed by sustained high levels and straightforward high levels. Especially, p53 shows two-phase dynamics upon moderated damage and the required number of p53 pulses before apoptosis induction decreases with increasing DNA damage. Our results suggested there exists an adaptive molecular timer that determines whether and when the apoptosis switch should be triggered. We clarified the mechanism behind the switching of p53 dynamical modes by bifurcation analysis. Moreover, we reproduced the experimental results that drug additions alter p53 pulses to sustained p53 activation and leads to senescence. Our work may advance the understanding the significance of p53 dynamics in tumor suppression. This work was supported by National Natural Science Foundation of China (Nos. 11175084, 11204126 and 31361163003).
Software for Acquiring Image Data for PIV
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Cheung, H. M.; Kressler, Brian
2003-01-01
PIV Acquisition (PIVACQ) is a computer program for acquisition of data for particle-image velocimetry (PIV). In the PIV system for which PIVACQ was developed, small particles entrained in a flow are illuminated with a sheet of light from a pulsed laser. The illuminated region is monitored by a charge-coupled-device camera that operates in conjunction with a data-acquisition system that includes a frame grabber and a counter-timer board, both installed in a single computer. The camera operates in "frame-straddle" mode where a pair of images can be obtained closely spaced in time (on the order of microseconds). The frame grabber acquires image data from the camera and stores the data in the computer memory. The counter/timer board triggers the camera and synchronizes the pulsing of the laser with acquisition of data from the camera. PIVPROC coordinates all of these functions and provides a graphical user interface, through which the user can control the PIV data-acquisition system. PIVACQ enables the user to acquire a sequence of single-exposure images, display the images, process the images, and then save the images to the computer hard drive. PIVACQ works in conjunction with the PIVPROC program which processes the images of particles into the velocity field in the illuminated plane.
Coubard, Olivier A
2016-01-01
Since the seminal report by Shapiro that bilateral stimulation induces cognitive and emotional changes, 26 years of basic and clinical research have examined the effects of Eye Movement Desensitization and Reprocessing (EMDR) in anxiety disorders, particularly in post-traumatic stress disorder (PTSD). The present article aims at better understanding EMDR neural mechanism. I first review procedural aspects of EMDR protocol and theoretical hypothesis about EMDR effects, and develop the reasons why the scientific community is still divided about EMDR. I then slide from psychology to physiology describing eye movements/emotion interaction from the physiological viewpoint, and introduce theoretical and technical tools used in movement research to re-examine EMDR neural mechanism. Using a recent physiological model for the neuropsychological architecture of motor and cognitive control, the Threshold Interval Modulation with Early Release-Rate of rIse Deviation with Early Release (TIMER-RIDER)-model, I explore how attentional control and bilateral stimulation may participate to EMDR effects. These effects may be obtained by two processes acting in parallel: (i) activity level enhancement of attentional control component; and (ii) bilateral stimulation in any sensorimotor modality, both resulting in lower inhibition enabling dysfunctional information to be processed and anxiety to be reduced. The TIMER-RIDER model offers quantitative predictions about EMDR effects for future research about its underlying physiological mechanisms.
Emotional trait and memory associates of sleep timing and quality.
Pace-Schott, Edward F; Rubin, Zoe S; Tracy, Lauren E; Spencer, Rebecca M C; Orr, Scott P; Verga, Patrick W
2015-10-30
Poor ability to remember the extinction of conditioned fear, elevated trait anxiety, and delayed or disrupted nocturnal sleep are reported in anxiety disorders. The current study examines the interrelationship of these factors in healthy young-adult males. Skin-conductance response was conditioned to two differently colored lamps. One color but not the other was then extinguished. After varying delays, both colors were presented to determine extinction recall and generalization. Questionnaires measured sleep quality, morningness-eveningness, neuroticism and trait anxiety. A subset produced a mean 7.0 nights of actigraphy and sleep diaries. Median split of mean sleep midpoint defined early- and late-"sleep timers". Extinction was more rapidly learned in the morning than evening only in early timers who also better generalized extinction recall. Extinction recall was greater with higher sleep efficiency. Sleep efficiency and morningness were negatively associated with neuroticism and anxiety. However, neuroticism and anxiety did not predict extinction learning, recall or generalization. Therefore, neuroticism/anxiety and deficient fear extinction, although both associated with poor quality and late timing of sleep, are not directly associated with each other. Elevated trait anxiety, in addition to predisposing directly to anxiety disorders, may thus also indirectly promote such disorders by impairing sleep and, consequently, extinction memory. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Akagi, Kazutaka; Sarhan, Moustafa; Sultan, Abdel-Rahman S; Nishida, Haruka; Koie, Azusa; Nakayama, Takumi; Ueda, Hitoshi
2016-07-01
During the development of multicellular organisms, many events occur with precise timing. In Drosophila melanogaster, pupation occurs about 12 h after puparium formation and its timing is believed to be determined by the release of a steroid hormone, ecdysone (E), from the prothoracic gland. Here, we demonstrate that the ecdysone-20-monooxygenase Shade determines pupation timing by converting E to 20-hydroxyecdysone (20E) in the fat body, which is the organ that senses nutritional status. The timing of shade expression is determined by its transcriptional activator βFtz-f1. The βftz-f1 gene is activated after a decline in the expression of its transcriptional repressor Blimp-1, which is temporally expressed around puparium formation in response to a high titer of 20E. The expression level and stability of Blimp-1 is critical for the precise timing of pupation. Thus, we propose that Blimp-1 molecules function like sand in an hourglass in this precise developmental timer system. Furthermore, our data suggest that a biological advantage results from both the use of a transcriptional repressor for time determination and the association of developmental timing with nutritional status of the organism. © 2016. Published by The Company of Biologists Ltd.
Increasing life expectancy of water resources literature
NASA Astrophysics Data System (ADS)
Heistermann, M.; Francke, T.; Georgi, C.; Bronstert, A.
2014-06-01
In a study from 2008, Larivière and colleagues showed, for the field of natural sciences and engineering, that the median age of cited references is increasing over time. This result was considered counterintuitive: with the advent of electronic search engines, online journal issues and open access publications, one could have expected that cited literature is becoming younger. That study has motivated us to take a closer look at the changes in the age distribution of references that have been cited in water resources journals since 1965. Not only could we confirm the findings of Larivière and colleagues. We were also able to show that the aging is mainly happening in the oldest 10-25% of an average reference list. This is consistent with our analysis of top-cited papers in the field of water resources. Rankings based on total citations since 1965 consistently show the dominance of old literature, including text books and research papers in equal shares. For most top-cited old-timers, citations are still growing exponentially. There is strong evidence that most citations are attracted by publications that introduced methods which meanwhile belong to the standard toolset of researchers and practitioners in the field of water resources. Although we think that this trend should not be overinterpreted as a sign of stagnancy, there might be cause for concern regarding how authors select their references. We question the increasing citation of textbook knowledge as it holds the risk that reference lists become overcrowded, and that the readability of papers deteriorates.
Defrost Temperature Termination in Supermarket Refrigeration Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fricke, Brian A; Sharma, Vishaldeep
2011-11-01
The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy,more » a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.« less
Assessment of SOI Devices and Circuits at Extreme Temperatures
NASA Technical Reports Server (NTRS)
Elbuluk, Malik; Hammoud, Ahmad; Patterson, Richard L.
2007-01-01
Electronics designed for use in future NASA space exploration missions are expected to encounter extreme temperatures and wide thermal swings. Such missions include planetary surface exploration, bases, rovers, landers, orbiters, and satellites. Electronics designed for such applications must, therefore, be able to withstand exposure to extreme temperatures and to perform properly for the duration of mission. The Low Temperature Electronics Program at the NASA Glenn Research Center focuses on research and development of electrical devices, circuits, and systems suitable for applications in deep space exploration missions and aerospace environment. Silicon-On-Insulator (SOI) technology has been under active consideration in the electronics industry for many years due to the advantages that it can provide in integrated circuit (IC) chips and computer processors. Faster switching, less power, radiationtolerance, reduced leakage, and high temp-erature capability are some of the benefits that are offered by using SOI-based devices. A few SOI circuits are available commercially. However, there is a noticeable interest in SOI technology for different applications. Very little data, however, exist on the performance of such circuits under cryogenic temperatures. In this work, the performance of SOI integrated circuits, evaluated under low temperature and thermal cycling, are reported. In particular, three examples of SOI circuits that have been tested for operation at low at temperatures are given. These circuits are SOI operational amplifiers, timers and power MOSFET drivers. The investigations were carried out to establish a baseline on the functionality and to determine suitability of these circuits for use in space exploration missions at cryogenic temperatures. The findings are useful to mission planners and circuit designers so that proper selection of electronic parts can be made, and risk assessment can be established for such circuits for use in space missions.
An updated rate-of-spread clock
Kolaks, Jeremy; Grabner, Keith W.; Hartman, George; Cutter, Bruce E.; Loewenstein, Edward F.
2005-01-01
Several years ago, Blank and Simard (1983) described an electronic timer, frequently referred to as a rate-of-spread (ROS) clock—a relatively simple instrument used in measuring fire spread. Although other techniques for measuring rate of spread are available (such as data loggers), the basic ROS clock remains a valuable and relatively inexpensive tool. However, several items described in the original article have changed. Therefore, we are describing an updated version of the ROS clock.
26. Photocopy of photograph. (Original is No. PI23488 in the ...
26. Photocopy of photograph. (Original is No. PI-23488 in the Seattle Post-Intelligencer Collection at the Museum of History and Industry (MOHAI), Seattle, WA. A print from the original negative can be ordered from MOHAI.) A 1937 view of the finish line viewed from the grandstand. Note original timer's stand (infield steward stand), original 'tote' board, and picket fencing. - Longacres, 1621 Southwest Sixteenth Street, Renton, King County, WA
NASA Technical Reports Server (NTRS)
Joerns, J. C.
1986-01-01
Pressure regulated and flow timed to control amount dispensed. Dispenser provides measured amount of water for reconstituting dehydrated foods and beverages. Dispenser holds food or beverage package while being filled with either cold or room-temperature water. Other uses might include dispensing of fluids or medicine. Pressure regulator in dispenser reduces varying pressure of water supply to constant pressure. Electronic timer stops flow after predetermined length of time. Timed flow at regulated pressure ensures controlled volume of water dispensed.
A Study of Underwater Sound Ray Tracing Methodology
1990-09-01
SRER ,LB,SV,SVU2,SVU,SU2,SU4,GI,G PIE = 3.14159265359D0 77 lEST = 0 MI = M C DISTRIBUTE THE K SOURCES EQUALLY AROUND THE CIRCLE COUNTER C CLOCKWISE...C(I) - TI-R(I TIMER(I = TIMCO) - T(5) HER(IW HC(I - Hl ZER(IW ZC(I - ZI SR = DSQRT(HI**2 + WA - Zl)**2) SRER = DSQRT(HC(I)**2 + (A2 - Zl)**2) - SR 50
ERIC Educational Resources Information Center
Spektor-Precel, Karen; Mioduser, David
2015-01-01
Nowadays, we are surrounded by artifacts that are capable of adaptive behavior, such as electric pots, boiler timers, automatic doors, and robots. The literature concerning human beings' conceptions of "traditional" artifacts is vast, however, little is known about our conceptions of behaving artifacts, nor of the influence of the…
Simulation of an Air Cushion Vehicle
1977-03-01
Massachusetts 02139 ! DDC Niov 219T March 1977 Final Report for Period January 1975 - December 1976 DOD DISTRIBUTION STATEMENT Approved for public...or in ,art is permitted for any purpose of the United States Government. II II JI UNCLASSI FIED SECURITY CLASSIFICATiON OF TIlS PAGE flWhen Dato...overflow Floating point fault Decimal arithmetic fault Watch Dog timer runout 186 NAVTRAEQUIPCEN 75-C-0057- 1 PROGRAM ENi\\TRY Initial Program - LOAD Inhibit
1992-06-01
Vi th this sampling schedule the data logger has enough (data. storage capacity for, a five yea r deploymeneit-. SYsteim specifica tionis are shown...sit [I t ille check is pwrformed as a virttial device. called -Ilinei check". which is scheduled in the task tabhe aid(] executed by the systsenm cot...PCI as FSK carrier detect input- add function (5) to do timer/counter control - stop counter when defaults set I 6. Instrument scheduler software
Solid State pH Sensor Based on Light Emitting Diodes (LED) As Detector Platform
Lau, King Tong; Shepherd, R.; Diamond, Danny; Diamond, Dermot
2006-01-01
A low-power, high sensitivity, very low-cost light emitting diode (LED)-based device developed for low-cost sensor networks was modified with bromocresol green membrane to work as a solid-state pH sensor. In this approach, a reverse-biased LED functioning as a photodiode is coupled with a second LED configured in conventional emission mode. A simple timer circuit measures how long (in microsecond) it takes for the photocurrent generated on the detector LED to discharge its capacitance from logic 1 (+5 V) to logic 0 (+1.7 V). The entire instrument provides an inherently digital output of light intensity measurements for a few cents. A light dependent resistor (LDR) modified with similar sensor membrane was also used as a comparison method. Both the LED sensor and the LDR sensor responded to various pH buffer solutions in a similar way to obtain sigmoidal curves expected of the dye. The pKa value obtained for the sensors was found to agree with the literature value.
Arrival Metering Precision Study
NASA Technical Reports Server (NTRS)
Prevot, Thomas; Mercer, Joey; Homola, Jeffrey; Hunt, Sarah; Gomez, Ashley; Bienert, Nancy; Omar, Faisal; Kraut, Joshua; Brasil, Connie; Wu, Minghong, G.
2015-01-01
This paper describes the background, method and results of the Arrival Metering Precision Study (AMPS) conducted in the Airspace Operations Laboratory at NASA Ames Research Center in May 2014. The simulation study measured delivery accuracy, flight efficiency, controller workload, and acceptability of time-based metering operations to a meter fix at the terminal area boundary for different resolution levels of metering delay times displayed to the air traffic controllers and different levels of airspeed information made available to the Time-Based Flow Management (TBFM) system computing the delay. The results show that the resolution of the delay countdown timer (DCT) on the controllers display has a significant impact on the delivery accuracy at the meter fix. Using the 10 seconds rounded and 1 minute rounded DCT resolutions resulted in more accurate delivery than 1 minute truncated and were preferred by the controllers. Using the speeds the controllers entered into the fourth line of the data tag to update the delay computation in TBFM in high and low altitude sectors increased air traffic control efficiency and reduced fuel burn for arriving aircraft during time based metering.
Tsang, V C; Wyatt, C R; Damian, R T
1979-06-01
The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.
Using WYSIWYG GUI Tools with UML
2009-06-01
diagram that shows the ports through which it sends and receives messages to and from other active classes. The behavior is described using a state...software that talks to its environment through ports (specified in the structure diagram), and performs actions as it transitions through a sequence of...used to trigger actions on the state diagram. As a result, the stimulus to these events is pro- vided by the system itself in the case of the timer port
A User Oriented Microcomputer and Monitor System.
1981-02-15
inhibit signal is generated by the Monitor to (1) prevent microcomputer bus timeout, and (2) suspend the micro- computer interval timers while the...PDPll is prevented until the user sets the BIT flag for the associated buffer memory. Completion of a buffer memory transfer generates monitor source...1553 NUX PIOU PRGRAMMED 10 IRECT MEMORY MONITOR 0I INTERAC JI LMEMOR COR POWER I J SUPPLIES 4 FIGURE 15. MICROCOMPUTER MAJOR AREAS 64 a uIu 1 ta 0 W o
Computer-controlled attenuator.
Mitov, D; Grozev, Z
1991-01-01
Various possibilities for applying electronic computer-controlled attenuators for the automation of physiological experiments are considered. A detailed description is given of the design of a 4-channel computer-controlled attenuator, in two of the channels of which the output signal can change by a linear step, in the other two channels--by a logarithmic step. This, together with the existence of additional programmable timers, allows to automate a wide range of studies in different spheres of physiology and psychophysics, including vision and hearing.
Bracing the Infantry’s Backbone for 21st Century Operations
2010-04-27
TERMS Strategic Corporal, NCO Training and Education, Enlisted Retention. 16 . SECURITY CLASSIFICATION OF: 17. LIMITATION OF 18. NUMBER ABSTRACT OF...Demographics and Why We Must Change .......... 9 Building the Backbone One Vertebrae at a Time: Fixing NCO Training and Education .. 16 Don’t Let a Good Thing...scorn of nearly everything on earth. .... They were the Leathernecks, the Old Timers: collected from ship’s guards and shore stations all over the
MEANS FOR VISUALIZING FLUID FLOW PATTERNS
Lynch, F.E.; Palmer, L.D.; Poppendick, H.F.; Winn, G.M.
1961-05-16
An apparatus is given for determining both the absolute and relative velocities of a phosphorescent fluid flowing through a transparent conduit. The apparatus includes a source for exciting a narrow trsnsverse band of the fluid to phosphorescence, detecting means such as a camera located downstream from the exciting source to record the shape of the phosphorescent band as it passes, and a timer to measure the time elapsed between operation of the exciting source and operation of the camera.
Coubard, Olivier A.
2016-01-01
Since the seminal report by Shapiro that bilateral stimulation induces cognitive and emotional changes, 26 years of basic and clinical research have examined the effects of Eye Movement Desensitization and Reprocessing (EMDR) in anxiety disorders, particularly in post-traumatic stress disorder (PTSD). The present article aims at better understanding EMDR neural mechanism. I first review procedural aspects of EMDR protocol and theoretical hypothesis about EMDR effects, and develop the reasons why the scientific community is still divided about EMDR. I then slide from psychology to physiology describing eye movements/emotion interaction from the physiological viewpoint, and introduce theoretical and technical tools used in movement research to re-examine EMDR neural mechanism. Using a recent physiological model for the neuropsychological architecture of motor and cognitive control, the Threshold Interval Modulation with Early Release-Rate of rIse Deviation with Early Release (TIMER-RIDER)—model, I explore how attentional control and bilateral stimulation may participate to EMDR effects. These effects may be obtained by two processes acting in parallel: (i) activity level enhancement of attentional control component; and (ii) bilateral stimulation in any sensorimotor modality, both resulting in lower inhibition enabling dysfunctional information to be processed and anxiety to be reduced. The TIMER-RIDER model offers quantitative predictions about EMDR effects for future research about its underlying physiological mechanisms. PMID:27092064
Faculty workload and collegial support related to proportion of part-time faculty composition.
Adams, D A
1995-10-01
Part-time faculty use has become more prevalent in higher education in response to enrollment shifts and budgetary constraints. This descriptive, exploratory study used a mailed survey to investigate whether full-time nursing faculty perceptions of workload and collegial support differ with changes in the proportion of part-time faculty in Comprehensive I baccalaureate nursing programs. Workload was measured by Dick's Workload Instrument. Collegial support was measured by the Survey of Collegial Communication, adapted by Beyer, which was based on Likert's organizational model. Schools were partitioned into three strata based on the proportion of part-time faculty employed (low, medium, and high). A 30% sample of schools were randomly selected from each stratum (10 schools from each). Within each selected school, six full-time undergraduate faculty were chosen by their respective deans to participate. The total response rate was 89.4%. The results of this study did not support assertions about part-time faculty use in the literature and existing accreditation standards. Findings indicated that there were significant differences in reported total faculty workload when varying proportions of part-time faculty are employed. Faculty in nursing programs with medium proportions of part-time faculty reported higher average total workloads per week than faculty in programs with low and high proportions of part-timers. Another finding demonstrated that full-time faculty in nursing programs with high proportions of part-time faculty spend fewer hours in direct clinical supervision of their students when compared with faculty in the other two strata. There were, however, no differences in perceived collegial support among full-time faculty participants. It was recommended that further research be conducted to investigate specific workload differences found in this study using more precise quantitative measures. Communication and collegiality between part-time and full-time faculty should be further developed and researched under more controlled conditions. Case studies of arrangements that make part-time faculty use beneficial are needed. Other variables such as leadership style, scholarly productivity, and morale and their relationship to the proportion of part-time faculty employed in the nursing program should be investigated.
NASA Technical Reports Server (NTRS)
Burleigh, Scott C.
2011-01-01
Contact Graph Routing (CGR) is a dynamic routing system that computes routes through a time-varying topology of scheduled communication contacts in a network based on the DTN (Delay-Tolerant Networking) architecture. It is designed to enable dynamic selection of data transmission routes in a space network based on DTN. This dynamic responsiveness in route computation should be significantly more effective and less expensive than static routing, increasing total data return while at the same time reducing mission operations cost and risk. The basic strategy of CGR is to take advantage of the fact that, since flight mission communication operations are planned in detail, the communication routes between any pair of bundle agents in a population of nodes that have all been informed of one another's plans can be inferred from those plans rather than discovered via dialogue (which is impractical over long one-way-light-time space links). Messages that convey this planning information are used to construct contact graphs (time-varying models of network connectivity) from which CGR automatically computes efficient routes for bundles. Automatic route selection increases the flexibility and resilience of the space network, simplifying cross-support and reducing mission management costs. Note that there are no routing tables in Contact Graph Routing. The best route for a bundle destined for a given node may routinely be different from the best route for a different bundle destined for the same node, depending on bundle priority, bundle expiration time, and changes in the current lengths of transmission queues for neighboring nodes; routes must be computed individually for each bundle, from the Bundle Protocol agent's current network connectivity model for the bundle s destination node (the contact graph). Clearly this places a premium on optimizing the implementation of the route computation algorithm. The scalability of CGR to very large networks remains a research topic. The information carried by CGR contact plan messages is useful not only for dynamic route computation, but also for the implementation of rate control, congestion forecasting, transmission episode initiation and termination, timeout interval computation, and retransmission timer suspension and resumption.
Nordstrom, M A; Mapletoft, E A; Miles, T S
1995-11-01
A solution is described for the acquisition on a personal computer of standard pulses derived from neuronal discharge, measurement of neuronal discharge times, real-time control of stimulus delivery based on specified inter-pulse interval conditions in the neuronal spike train, and on-line display and analysis of the experimental data. The hardware consisted of an Apple Macintosh IIci computer and a plug-in card (National Instruments NB-MIO16) that supports A/D, D/A, digital I/O and timer functions. The software was written in the object-oriented graphical programming language LabView. Essential elements of the source code of the LabView program are presented and explained. The use of the system is demonstrated in an experiment in which the reflex responses to muscle stretch are assessed for a single motor unit in the human masseter muscle.
Implementing finite state machines in a computer-based teaching system
NASA Astrophysics Data System (ADS)
Hacker, Charles H.; Sitte, Renate
1999-09-01
Finite State Machines (FSM) are models for functions commonly implemented in digital circuits such as timers, remote controls, and vending machines. Teaching FSM is core in the curriculum of many university digital electronic or discrete mathematics subjects. Students often have difficulties grasping the theoretical concepts in the design and analysis of FSM. This has prompted the author to develop an MS-WindowsTM compatible software, WinState, that provides a tutorial style teaching aid for understanding the mechanisms of FSM. The animated computer screen is ideal for visually conveying the required design and analysis procedures. WinState complements other software for combinatorial logic previously developed by the author, and enhances the existing teaching package by adding sequential logic circuits. WinState enables the construction of a students own FSM, which can be simulated, to test the design for functionality and possible errors.
LED instrument approach instruction display
NASA Technical Reports Server (NTRS)
Meredith, B. D.; Kelly, W. L., IV; Crouch, R. K.
1979-01-01
A display employing light emitting diodes (LED's) was developed to demonstrate the feasibility of such displays for presenting landing and navigation information to reduce the workload of general aviation pilots during IFR flight. The display consists of a paper tape reader, digital memory, control electronics, digital latches, and LED alphanumeric displays. A presentable digital countdown clock-timer is included as part of the system to provide a convenient means of monitoring time intervals for precise flight navigation. The system is a limited capability prototype assembled to test pilot reaction to such a device under simulated IFR operation. Pilot opinion indicates that the display is helpful in reducing the IFR pilots workload when used with a runway approach plate. However, the development of a compact, low power second generation display was recommended which could present several instructions simultaneously and provide information update capability. A microprocessor-based display could fulfill these requirements.
Measuring average angular velocity with a smartphone magnetic field sensor
NASA Astrophysics Data System (ADS)
Pili, Unofre; Violanda, Renante
2018-02-01
The angular velocity of a spinning object is, by standard, measured using a device called a tachometer. However, by directly using it in a classroom setting, the activity is likely to appear as less instructive and less engaging. Indeed, some alternative classroom-suitable methods for measuring angular velocity have been presented. In this paper, we present a further alternative that is smartphone-based, making use of the real-time magnetic field (simply called B-field in what follows) data gathering capability of the B-field sensor of the smartphone device as the timer for measuring average rotational period and average angular velocity. The in-built B-field sensor in smartphones has already found a number of uses in undergraduate experimental physics. For instance, in elementary electrodynamics, it has been used to explore the well-known Bio-Savart law and in a measurement of the permeability of air.
Electrical Textile Valves for Paper Microfluidics.
Ainla, Alar; Hamedi, Mahiar M; Güder, Firat; Whitesides, George M
2017-10-01
This paper describes electrically-activated fluidic valves that operate based on electrowetting through textiles. The valves are fabricated from electrically conductive, insulated, hydrophobic textiles, but the concept can be extended to other porous materials. When the valve is closed, the liquid cannot pass through the hydrophobic textile. Upon application of a potential (in the range of 100-1000 V) between the textile and the liquid, the valve opens and the liquid penetrates the textile. These valves actuate in less than 1 s, require low energy (≈27 µJ per actuation), and work with a variety of aqueous solutions, including those with low surface tension and those containing bioanalytes. They are bistable in function, and are, in a sense, the electrofluidic analog of thyristors. They can be integrated into paper microfluidic devices to make circuits that are capable of controlling liquid, including autonomous fluidic timers and fluidic logic. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Backup control airstart performance on a digital electronic engine control-equipped F100-engine
NASA Technical Reports Server (NTRS)
Johnson, J. B.
1984-01-01
The air start capability of a backup control (BUC) was tested for a digital electronic engine control (DEEC) equipped F100 engine, which was installed in an F-15 aircraft. Two air start schedules were tested. Using the group 1 start schedule, based on a 40 sec timer, an air speed of 300 knots was required to ensure successful 40 and 25% BUC mode spooldown airstarts. If core rotor speed (N2) was less than 40% a stall would occur when the start bleed closed, 40 sec after initiation of the air start. All jet fuel starter (JFS) assisted air starts were successful with the group 1 start schedule. For the group 2 schedule, the time between pressurization and start bleed closure ranged between 50 sec and 72 sec. Idle rps was lower than the desired 65% for air starts at higher altitudes and lower air speeds.
A fast embedded readout system for large-area Medipix and Timepix systems
NASA Astrophysics Data System (ADS)
Brogna, A. S.; Balzer, M.; Smale, S.; Hartmann, J.; Bormann, D.; Hamann, E.; Cecilia, A.; Zuber, M.; Koenig, T.; Zwerger, A.; Weber, M.; Fiederle, M.; Baumbach, T.
2014-05-01
In this work we present a novel readout electronics for an X-ray sensor based on a Si crystal bump-bonded to an array of 3 × 2 Medipix ASICs. The pixel size is 55 μm × 55 μm with a total number of ~ 400k pixels and a sensitive area of 42 mm × 28 mm. The readout electronics operate Medipix-2 MXR or Timepix ASICs with a clock speed of 125 MHz. The data acquisition system is centered around an FPGA and each of the six ASICs has a dedicated I/O port for simultaneous data acquisition. The settings of the auxiliary devices (ADCs and DACs) are also processed in the FPGA. Moreover, a high-resolution timer operates the electronic shutter to select the exposure time from 8 ns to several milliseconds. A sophisticated trigger is available in hardware and software to synchronize the acquisition with external electro-mechanical motors. The system includes a diagnostic subsystem to check the sensor temperature and to control the cooling Peltier cells and a programmable high-voltage generator to bias the crystal. A network cable transfers the data, encapsulated into the UDP protocol and streamed at 1 Gb/s. Therefore most notebooks or personal computers are able to process the data and to program the system without a dedicated interface. The data readout software is compatible with the well-known Pixelman 2.x running both on Windows and GNU/Linux. Furthermore the open architecture encourages users to write their own applications. With a low-level interface library which implements all the basic features, a MATLAB or Python script can be implemented for special manipulations of the raw data. In this paper we present selected images taken with a microfocus X-ray tube to demonstrate the capability to collect the data at rates up to 120 fps corresponding to 0.76 Gb/s.
Electromechanical Actuator Performance of Carbon Nanotube Fibers
NASA Astrophysics Data System (ADS)
Munoz, Edgar; Kozlov, Mikhail; Collins, Steve; Dalton, Alan B.; Razal, Joselito; Zakhidov, Anvar A.; Baughman, Ray H.
2003-03-01
Single-walled carbon nanotube (SWNT) assemblies (sheets and fibers) have been investigated as electromechanical actuators. SWNT fibers provide maximum isometric actuator stress values of 20-26 MPa, which is about 5-10 times larger that those corresponding to SWNT sheets. This actuation performance is about 100 timer larger than the stress generation capability of natural muscle. The effect of employing different electrolytes as well as SWNTs produced by different routes, and the potential applications of these actuators will be also discussed.
Balancing Work Responsibilities and Family Needs: The Federal Civil Service Response
1991-11-01
Since better part-time benefits package than some other our analysis unco’ ered no substantive drawbacks employers . Federal part-timers are typically...Government can improve its status as a/model employer in the work and family benefits area. ( o/ I hope you will find this report useful as you develop plans...Xiii OVERVIEW "Cafeteria" Benefits : Conclusions: The Government does not offer a "cafeteria" As an employer , the Federal Government has a benefits
2008-09-01
thermostats, or materials such as carbon layers, which vary in thickness with location and are self - healing and self - regulating. Ships commonly use heating...aircraft today. Pneumatic deicing systems consist of rubber or other elastomeric boots placed on the leading edge of an aircraft wing or on any surface...by Kenney, two as- semblies consisting of neoprene rubber and urethane-coated Dacron fabric were hung from bulkheads where icing would occur. A timer
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. House Committee on Education and Labor.
Hearins on reauthorization of the Higher Education Act of 1965 consider the needs of the nontraditional student in higher education. Consideration is given to ways that student financial aid programs could better serve this student population (i.e., students may be over ages 18 to 22, may be minority group members or immigrants, part-timers, out…
ERIC Educational Resources Information Center
Connecticut State Board of Higher Education, Hartford.
The collective bargaining agreement between Connecticut State University Board of Trustees and the Connecticut State University chapter of the American Association of University Professors covering the period April 10, 1984 to April 10, 1987 is presented. The chapter has 1,980 members, including part-timers. Items covered in the agreement include:…
Analysis of Display Latency for 3D Perceptual Experiments
2016-11-01
the 3D mode on and recorded the experiment using only one of the two images on the display in 2D mode. Within our experimental code, a “tic- toc ...timer was added. A tic time was recorded when the command for fixation offset executed, and the toc was recorded when the command for stimulus onset...executed. The difference between toc and tic gives us the machine ISI time which we can compare to the recorded display ISI. This value should be
Automated single-slide staining device. [in clinical bacteriology
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Mills, S. M.
1975-01-01
An automatic single-slide Gram staining device is described. A timer-actuated solenoid controls the dispensing of gentian violet, Gram iodine solution, decolorizer, and 1% aqueous safranin in proper sequence and for the time required for optimum staining. The amount of stain or reagent delivered is controlled by means of stopcocks below each solenoid. Used stains and reagents can be flushed automatically or manually. Smears Gram stained automatically are equal in quality to those prepared manually. The time to complete one Gram cycle is 4.80 min.
A practical example aiding understanding momentum in 1D: the water gun experiment
NASA Astrophysics Data System (ADS)
MacLeod, Katarin
2007-09-01
The law of conservation of momentum is one that students often have difficulties understanding. This experiment allows students to use childhood toys to examine and calculate the muzzle velocity of their favourite water gun by using an air track, a spark timer or data logger and the law of conservation of momentum in a one-dimensional case, a modification of the standard ballistic pendulum laboratory experiment (1990 Physics 100 Lab Manual St Francis Xavier University).
Nuclear electric power sources
NASA Technical Reports Server (NTRS)
Singh, J. J.
1978-01-01
Measurements on radioactive commercial p-n junction silicon cells show that these units are capable of delivering several hundred microwatts per curie of Am-241 alpha source, indicating their usefulness in such electronic devices as hearing aids, heart pacemakers, electronic watches, delay timers and nuclear dosimeter chargers. It is concluded that the Am-241 sources are superior to the beta sources used previously, because of higher alpha specific ionization and simultaneous production of low energy photons which are easily converted into photoelectrons for additional power.
Predicting threshold and location of laser damage on optical surfaces
Siekhaus, Wigbert
1987-01-01
An apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities comprising, a focused and pulsed laser, an photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.
Er, Buket; Demirhan, Burak; Onurdag, Fatma Kaynak; Ozgacar, Selda Özgen; Oktem, Aysel Bayhan
2014-03-01
Salmonella spp. are widespread foodborne pathogens that contaminate egg and poultry meats. Attachment, colonization, as well as biofilm formation capacity of Salmonella spp. on food and contact surfaces of food may cause continuous contamination. Biofilm may play a crucial role in the survival of salmonellae under unfavorable environmental conditions, such as in animal slaughterhouses and processing plants. This could serve as a reservoir compromising food safety and human health. Addition of antimicrobial preservatives extends shelf lives of food products, but even when products are supplemented with adequate amounts of preservatives, it is not always possible to inhibit the microorganisms in a biofilm community. In this study, our aims were i) to determine the minimum inhibitory concentrations (MIC) and minimum biofilm inhibitory concentrations (MBIC) of selected preservatives against planktonic and biofilm forms of Salmonella spp. isolated from chicken samples and Salmonella Typhimurium SL1344 standard strain, ii) to show the differences in the susceptibility patterns of same strains versus the planktonic and biofilm forms to the same preservative agent, and iii) to determine and compare antimicrobial and antibiofilm effects of selected food preservatives against Salmonella spp. For this purpose, Salmonella Typhimurium SL1344 standard strain and 4 Salmonella spp. strains isolated from chicken samples were used. Investigation of antimicrobial and antibiofilm effects of selected food preservatives against Salmonella spp. was done according to Clinical and Laboratory Standards Institute M100-S18 guidelines and BioTimer assay, respectively. As preservative agents, pure ciprofloxacin, sodium nitrite, potassium sorbate, sodium benzoate, methyl paraben, and propyl paraben were selected. As a result, it was determined that MBIC values are greater than the MIC values of the preservatives. This result verified the resistance seen in a biofilm community to food preservatives and highlighted this subject, not to be ignored in food applications.
The physics of bacterial decision making.
Ben-Jacob, Eshel; Lu, Mingyang; Schultz, Daniel; Onuchic, Jose' N
2014-01-01
The choice that bacteria make between sporulation and competence when subjected to stress provides a prototypical example of collective cell fate determination that is stochastic on the individual cell level, yet predictable (deterministic) on the population level. This collective decision is performed by an elaborated gene network. Considerable effort has been devoted to simplify its complexity by taking physics approaches to untangle the basic functional modules that are integrated to form the complete network: (1) A stochastic switch whose transition probability is controlled by two order parameters-population density and internal/external stress. (2) An adaptable timer whose clock rate is normalized by the same two previous order parameters. (3) Sensing units which measure population density and external stress. (4) A communication module that exchanges information about the cells' internal stress levels. (5) An oscillating gate of the stochastic switch which is regulated by the timer. The unique circuit architecture of the gate allows special dynamics and noise management features. The gate opens a window of opportunity in time for competence transitions, during which the circuit generates oscillations that are translated into a chain of short intervals with high transition probability. In addition, the unique architecture of the gate allows filtering of external noise and robustness against variations in circuit parameters and internal noise. We illustrate that a physics approach can be very valuable in investigating the decision process and in identifying its general principles. We also show that both cell-cell variability and noise have important functional roles in the collectively controlled individual decisions.
Accurate Sample Time Reconstruction of Inertial FIFO Data.
Stieber, Sebastian; Dorsch, Rainer; Haubelt, Christian
2017-12-13
In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO) interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts-introduced by fabrication inaccuracies, temperature changes and wear-out effects-onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS) technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.
The physics of bacterial decision making
Ben-Jacob, Eshel; Lu, Mingyang; Schultz, Daniel; Onuchic, Jose' N.
2014-01-01
The choice that bacteria make between sporulation and competence when subjected to stress provides a prototypical example of collective cell fate determination that is stochastic on the individual cell level, yet predictable (deterministic) on the population level. This collective decision is performed by an elaborated gene network. Considerable effort has been devoted to simplify its complexity by taking physics approaches to untangle the basic functional modules that are integrated to form the complete network: (1) A stochastic switch whose transition probability is controlled by two order parameters—population density and internal/external stress. (2) An adaptable timer whose clock rate is normalized by the same two previous order parameters. (3) Sensing units which measure population density and external stress. (4) A communication module that exchanges information about the cells' internal stress levels. (5) An oscillating gate of the stochastic switch which is regulated by the timer. The unique circuit architecture of the gate allows special dynamics and noise management features. The gate opens a window of opportunity in time for competence transitions, during which the circuit generates oscillations that are translated into a chain of short intervals with high transition probability. In addition, the unique architecture of the gate allows filtering of external noise and robustness against variations in circuit parameters and internal noise. We illustrate that a physics approach can be very valuable in investigating the decision process and in identifying its general principles. We also show that both cell-cell variability and noise have important functional roles in the collectively controlled individual decisions. PMID:25401094
NASA Astrophysics Data System (ADS)
Baskoro, F.; Reynaldo, B. R.
2018-04-01
The development of electronics technology especially in the field of microcontroller occurs very rapidly. There have been many applications and useful use of microcontroller in everyday life as well as in laboratory research. In this study used Arduino Uno R3 as microcontroller-based platform ATMega328 as a sensor distance meter to know the distance of an object with high accuracy. The method used is to utilize the function Timer / Counter in Arduino UNO R3. On the Arduino Uno R3 platform, there is ATMEL ATmega328 microcontroller which has a frequency generating speed up to 20 MHz, 16-bit enumeration capability and using C language as its programming. With the Arduino Uno R3 platform, the ATmega328 microcontroller can be programmed with Arduino IDE software that is simpler and easier because it has been supported by libraries and many support programs. The result of this research is distance measurement to know the location of an object using US ultrasonic wave sensor US 100 with Arduino Uno R3 based on ATMega328 microcontroller which then the result will be displayed using Image Processing.
pFlogger: The Parallel Fortran Logging Utility
NASA Technical Reports Server (NTRS)
Clune, Tom; Cruz, Carlos A.
2017-01-01
In the context of high performance computing (HPC), software investments in support of text-based diagnostics, which monitor a running application, are typically limited compared to those for other types of IO. Examples of such diagnostics include reiteration of configuration parameters, progress indicators, simple metrics (e.g., mass conservation, convergence of solvers, etc.), and timers. To some degree, this difference in priority is justifiable as other forms of output are the primary products of a scientific model and, due to their large data volume, much more likely to be a significant performance concern. In contrast, text-based diagnostic content is generally not shared beyond the individual or group running an application and is most often used to troubleshoot when something goes wrong. We suggest that a more systematic approach enabled by a logging facility (or 'logger)' similar to those routinely used by many communities would provide significant value to complex scientific applications. In the context of high-performance computing, an appropriate logger would provide specialized support for distributed and shared-memory parallelism and have low performance overhead. In this paper, we present our prototype implementation of pFlogger - a parallel Fortran-based logging framework, and assess its suitability for use in a complex scientific application.
SU-E-T-459: Impact of Source Position and Traveling Time On HDR Skin Surface Applicator Dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeong, J; Barker, C; Zaider, M
Purpose: Observed dosimetric discrepancy between measured and treatment planning system (TPS) predicted values, during applicator commissioning, were traced to source position uncertainty in the applicator. We quantify the dosimetric impact of this geometric uncertainty, and of the source traveling time inside the applicator, and propose corrections for clinical use. Methods: We measured the dose profiles from the Varian Leipzig-style (horizontal) HDR skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter (OSLD) and three different GammaMed HDR afterloders. The dose profiles and depth dose of each aperture were measured at several depths (up to about 10 mm, dependingmore » on the dosimeter). The measured dose profiles were compared with Acuros calculated profiles in BrachyVision TPS. For the impact of the source position, EBT3 film measurements were performed with applicator, facing-down and facing-up orientations. The dose with and without source traveling was measured with diode detector using HDR timer and electrometer timer, respectively. Results: Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator facing-up were significantly lower than those in the facing-down position with maximum difference of about 18% at the surface, due to source sag inside the applicator. Based on the inverse-square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose from the source traveling was about 2.8% for 30 seconds with 10 Ci source, decreasing with increased dwelling time and decreased source activity. Conclusion: Due to the short source-to-surface distance of the applicator, the small source sag inside the applicator has significant dosimetric impact, which should be considered before the clinical use of the applicator. Investigation of the effect for other applicators that have relatively large source lumen inner diameter may be warranted. Christopher Barker and Gil’ad Cohen are receiving research support for a study of skin surface brachytherapy from Elekta.« less
NASA Technical Reports Server (NTRS)
Nolt, Gary D.
1988-01-01
Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.
Genesis Sample Return Capsule Overview
NASA Technical Reports Server (NTRS)
Willcockson, Bill
2005-01-01
I. Simple Entry Capsule Concept: a) Spin-Stabilized/No Active Control Systems; b) Ballistic Entry for 11.04 km/sec Velocity; c) No Heatshield Separation During Entry; d) Parachute Deploy via g-Switch + Timer. II. Stardust Design Inheritance a) Forebody Shape; b) Seal Concepts; c) Parachute Deploy Control; d) Utah Landing Site (UTTR). III. TPS Systems a) Heatshield - Carbon-Carbon - First Planetary Entry; b) Backshell - SLA-561V - Flight Heritage from Pathfinder, MER; d) Forebody Structural Penetrations Aerothermal and TPS Design Process has the Same Methodology as Used for Pathfinder, MER Flight Vehicles.
A device for recording automatic audio tape recording1
Bernal, Martha E.; Gibson, Dennis M.; Williams, Donald E.; Pesses, Danny I.
1971-01-01
Adaptation of a commercially available timer for use as a means of operating an audio tape recorder several times during the day is described. Data on a mother's rates of commanding her children were collected via both physically present observer and recorder methods in order to compare the usefulness of the recordings with direct observation. There was a high positive relationship between observer-recorder command rates, with the observer rates being consistently higher, when data were collected via both methods simultaneously as well as at different points in time. ImagesFig. 1 PMID:16795287
A device for recording automatic audio tape recording.
Bernal, M E; Gibson, D M; Williams, D E; Pesses, D I
1971-01-01
Adaptation of a commercially available timer for use as a means of operating an audio tape recorder several times during the day is described. Data on a mother's rates of commanding her children were collected via both physically present observer and recorder methods in order to compare the usefulness of the recordings with direct observation. There was a high positive relationship between observer-recorder command rates, with the observer rates being consistently higher, when data were collected via both methods simultaneously as well as at different points in time.
Magnetic Field Sensing with Nitrogen-Vacancy Color Centers in Diamond
2013-05-01
8217d from r.haracteristic time of the der.ay enwlop<’. as shown in Figm<’ 1.7(b). For an ensemble of NV centers , inhomogeneities stemming from the...Backgnmnd a initialization detection optical _.J:.D ____. __________ __._n....__ b 350 "E 300 ~ 250 (jj §, 200 Cll Ŕ 150 l!l ~ 100 ~ 50 0...Free Precession Time-r (J.IS) II) ---(ij c .2’ (/) Cll (J c :!l e 0 ::J u: 0 0.5 15 2 Static Magnetic Field B (G) Figurr A. 2
1955-04-01
counterweights to adjust the blade static moment about the quarter chord, and the blade centrifugal forces are transferred to the hub by means of two...directly on a series of dials. The one-per-revolution rotor-speed timer consisted of a spring-loaded brush- contactor arrangement which effected a...moment which results when centrifugal forces act on the blade-retention straps. 8 NACA TN 3376 The results shown in figure 11, however, should be
University of Hawaii Lure Observatory. [lunar laser ranging system construction
NASA Technical Reports Server (NTRS)
Carter, W. E.; Williams, J. D.
1973-01-01
The University of Hawaii's Institute for Astronomy is currently constructing a lunar laser ranging observatory at the 3050-meter summit of Mt. Haleakala, Hawaii. The Nd YAG laser system to be employed provides three pulses per second, each pulse being approximately 200 picoseconds in duration. The energy contained in one pulse at 5320 A lies in the range from 250 to 350 millijoules. Details of observatory construction are provided together with transmitter design data and information concerning the lunastat, the feed telescope, the relative pointing system, the receiver, and the event timer system.
Payload specialists Millie Hughes-Fulford in Body Mass Measurement Device
1985-02-01
S85-26553 (Feb 1985) --- STS-40/SLS-1 payload specialist Millie Hughes-Fulford sits strapped in the special device scientists have developed for determining mass on orbit. As the chair swings back and forth, a timer records how much the crewmember's mass retards the chair's movement. Dr. Hughes-Fulford will be joined by three mission specialists, the mission commander, the pilot and a second payload specialist for the scheduled 10-day Spacelab Life Sciences-1 (SLS-1) mission. The flight is totally dedicated to biological and medical experimentation.
Predicting threshold and location of laser damage on optical surfaces
Siekhaus, W.
1985-02-04
Disclosed is an apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities. The apparatus comprises a focused and pulsed laser, a photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrini, Fabrizio; Nieplocha, Jarek; Tipparaju, Vinod
2006-04-15
In this paper we will present a new technology that we are currently developing within the SFT: Scalable Fault Tolerance FastOS project which seeks to implement fault tolerance at the operating system level. Major design goals include dynamic reallocation of resources to allow continuing execution in the presence of hardware failures, very high scalability, high efficiency (low overhead), and transparency—requiring no changes to user applications. Our technology is based on a global coordination mechanism, that enforces transparent recovery lines in the system, and TICK, a lightweight, incremental checkpointing software architecture implemented as a Linux kernel module. TICK is completely user-transparentmore » and does not require any changes to user code or system libraries; it is highly responsive: an interrupt, such as a timer interrupt, can trigger a checkpoint in as little as 2.5μs; and it supports incremental and full checkpoints with minimal overhead—less than 6% with full checkpointing to disk performed as frequently as once per minute.« less
Radiation characterization report for the GPS Receiver microcontroller chip. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-06-20
The overall objective of this characterization test was to determine the sensitivity of the Motorola 68332 32-bit microcontroller to radiation induced single event upset and latch-up (SEU/SEL). The microcontroller is a key component of the GPS Receiver which will be a subsystem of the satellite required for the {open_quotes}FORTE{close_quotes} experiment. Testing was conducted at the Single Event Effects Laboratory at Brookhaven National Laboratory. The results obtained included a latch-up (SEL) threshold LET (Linear Energy Transfer) of 20 MeV-CM{sub 2}/mg and an upset (SEU) threshold LET of 5 MeV-CM{sup 2}/mg. The SEU threshold is typical of this technology, commercial 0.8{mu}m HCMOS.more » Some flow errors were observed that were not reset by the internal watchdog timer of the 68332. It is important that the Receiver design include a monitor of the device, such as an external watch-dog timer, that would initiate a reset of the program when this type of upset occurs. The SEL threshold is lower than would be expected for this 12{mu}m epi layer process and suggests the need for a strategy that would allow for a hard reset of the controller when a latch-up event occurs. Analysis of the galactic cosmic ray spectrum for the FORTE orbit was done and the results indicate a worst case latch-up rate for this device of 6.3 {times} 10{sup {minus}5} latch-ups per device day or roughly one latch-up per 43.5 device years.« less
Chronology of Islet Differentiation Revealed By Temporal Cell Labeling
Miyatsuka, Takeshi; Li, Zhongmei; German, Michael S.
2009-01-01
OBJECTIVE Neurogenin 3 plays a pivotal role in pancreatic endocrine differentiation. Whereas mouse models expressing reporters such as eGFP or LacZ under the control of the Neurog3 gene enable us to label cells in the pancreatic endocrine lineage, the long half-life of most reporter proteins makes it difficult to distinguish cells actively expressing neurogenin 3 from differentiated cells that have stopped transcribing the gene. RESEARCH DESIGN AND METHODS In order to separate the transient neurogenin 3 –expressing endocrine progenitor cells from the differentiating endocrine cells, we developed a mouse model (Ngn3-Timer) in which DsRed-E5, a fluorescent protein that shifts its emission spectrum from green to red over time, was expressed transgenically from the NEUROG3 locus. RESULTS In the Ngn3-Timer embryos, green-dominant cells could be readily detected by microscopy or flow cytometry and distinguished from green/red double-positive cells. When fluorescent cells were sorted into three different populations by a fluorescence-activated cell sorter, placed in culture, and then reanalyzed by flow cytometry, green-dominant cells converted to green/red double-positive cells within 6 h. The sorted cell populations were then used to determine the temporal patterns of expression for 145 transcriptional regulators in the developing pancreas. CONCLUSIONS The precise temporal resolution of this model defines the narrow window of neurogenin 3 expression in islet progenitor cells and permits sequential analyses of sorted cells as well as the testing of gene regulatory models for the differentiation of pancreatic islet cells. PMID:19478145
Measurement of g Using a Flashing LED
NASA Astrophysics Data System (ADS)
Terzella, T.; Sundermier, J.; Sinacore, J.; Owen, C.; Takai, H.
2008-10-01
In one of the classic free-fall experiments, a small mass is attached to a strip of paper tape and both are allowed to fall through a spark timer, where sparks are generated at regular time intervals. Students analyze marks (dots) left on the tape by the timer, thereby generating distance-versus-time data, which they analyze to extract the acceleration due to gravity g with good results. The apparatus, however, is cumbersome and often frustrating for students. High-tech versions of this experiment are done with an object dropped and followed by a motion sensor connected to a computer. The sensor relies on ultrasonic ranging to record distance and time data, which may then be displayed graphically. Students inspect the graphs to determine the value of g. Although the results are excellent, the emphasis on the computer's ability to collect and analyze data leaves little analysis for the students to perform.2 Furthermore, neither technique gives an intuitive display of what is happening. The motivation for our work was to overcome these issues by developing an innovative method for measuring g. In our version of the experiment, students drop a flashing LED at a known frequency and record its trajectory using long exposure photography with a digital camera. Proper choice of flashing LED timing parameters produces an image that allows for an accurate measurement of g and at the same time helps to explain what happens during free fall. The experiment remains high-tech in the sense that students learn to use updated equipment to record data and to carry out the analysis.
An implementation of the SNR high speed network communication protocol (Receiver part)
NASA Astrophysics Data System (ADS)
Wan, Wen-Jyh
1995-03-01
This thesis work is to implement the receiver pan of the SNR high speed network transport protocol. The approach was to use the Systems of Communicating Machines (SCM) as the formal definition of the protocol. Programs were developed on top of the Unix system using C programming language. The Unix system features that were adopted for this implementation were multitasking, signals, shared memory, semaphores, sockets, timers and process control. The problems encountered, and solved, were signal loss, shared memory conflicts, process synchronization, scheduling, data alignment and errors in the SCM specification itself. The result was a correctly functioning program which implemented the SNR protocol. The system was tested using different connection modes, lost packets, duplicate packets and large data transfers. The contributions of this thesis are: (1) implementation of the receiver part of the SNR high speed transport protocol; (2) testing and integration with the transmitter part of the SNR transport protocol on an FDDI data link layered network; (3) demonstration of the functions of the SNR transport protocol such as connection management, sequenced delivery, flow control and error recovery using selective repeat methods of retransmission; and (4) modifications to the SNR transport protocol specification such as corrections for incorrect predicate conditions, defining of additional packet types formats, solutions for signal lost and processes contention problems etc.
Biomechanics of Single Cortical Neurons
Bernick, Kristin B.; Prevost, Thibault P.; Suresh, Subra; Socrate, Simona
2011-01-01
This study presents experimental results and computational analysis of the large strain dynamic behavior of single neurons in vitro with the objective of formulating a novel quantitative framework for the biomechanics of cortical neurons. Relying on the atomic force microscopy (AFM) technique, novel testing protocols are developed to enable the characterization of neural soma deformability over a range of indentation rates spanning three orders of magnitude – 10, 1, and 0.1 μm/s. Modified spherical AFM probes were utilized to compress the cell bodies of neonatal rat cortical neurons in load, unload, reload and relaxation conditions. The cell response showed marked hysteretic features, strong non-linearities, and substantial time/rate dependencies. The rheological data were complemented with geometrical measurements of cell body morphology, i.e. cross-diameter and height estimates. A constitutive model, validated by the present experiments, is proposed to quantify the mechanical behavior of cortical neurons. The model aimed to correlate empirical findings with measurable degrees of (hyper-) elastic resilience and viscosity at the cell level. The proposed formulation, predicated upon previous constitutive model developments undertaken at the cortical tissue level, was implemented into a three-dimensional finite element framework. The simulated cell response was calibrated to the experimental measurements under the selected test conditions, providing a novel single cell model that could form the basis for further refinements. PMID:20971217
Launching Payloads Into Orbit at Relatively Low Cost
NASA Technical Reports Server (NTRS)
Wilcox, Brian
2007-01-01
A report proposes the development of a system for launching payloads into orbit at about one-fifth the cost per unit payload weight of current systems. The PILOT system was a solid-fuel, aerodynamically spun and spin-stabilized, five-stage rocket with onboard controls including little more than an optoelectronic horizon sensor and a timer for triggering the second and fifth stages, respectively. The proposal calls for four improvements over the PILOT system to enable control of orbital parameters: (1) the aerodynamic tipover of the rocket at the top of the atmosphere could be modeled as a nonuniform gyroscopic precession and could be controlled by selection of the initial rocket configuration and launch conditions; (2) the attitude of the rocket at the top of the first-stage trajectory could be measured by use of radar tracking or differential Global Positioning System receivers to determine when to trigger the second stage; (3) the final-stage engines could be configured around the payload to enhance spin stabilization during a half-orbit coast up to apoapsis where the final stage would be triggered; and (4) the final payload stage could be equipped with a "beltline" of small thrusters for correcting small errors in the trajectory as measured by an off-board tracking subsystem.
Black, James; Gerdtz, Marie; Nicholson, Pat; Crellin, Dianne; Browning, Laura; Simpson, Julie; Bell, Lauren; Santamaria, Nick
2015-05-01
Respiratory rate is an important sign that is commonly either not recorded or recorded incorrectly. Mobile phone ownership is increasing even in resource-poor settings. Phone applications may improve the accuracy and ease of counting of respiratory rates. The study assessed the reliability and initial users' impressions of four mobile phone respiratory timer approaches, compared to a 60-second count by the same participants. Three mobile applications (applying four different counting approaches plus a standard 60-second count) were created using the Java Mobile Edition and tested on Nokia C1-01 phones. Apart from the 60-second timer application, the others included a counter based on the time for ten breaths, and three based on the time interval between breaths ('Once-per-Breath', in which the user presses for each breath and the application calculates the rate after 10 or 20 breaths, or after 60s). Nursing and physiotherapy students used the applications to count respiratory rates in a set of brief video recordings of children with different respiratory illnesses. Limits of agreement (compared to the same participant's standard 60-second count), intra-class correlation coefficients and standard errors of measurement were calculated to compare the reliability of the four approaches, and a usability questionnaire was completed by the participants. There was considerable variation in the counts, with large components of the variation related to the participants and the videos, as well as the methods. None of the methods was entirely reliable, with no limits of agreement better than -10 to +9 breaths/min. Some of the methods were superior to the others, with ICCs from 0.24 to 0.92. By ICC the Once-per-Breath 60-second count and the Once-per-Breath 20-breath count were the most consistent, better even than the 60-second count by the participants. The 10-breath approaches performed least well. Users' initial impressions were positive, with little difference between the applications found. This study provides evidence that applications running on simple phones can be used to count respiratory rates in children. The Once-per-Breath methods are the most reliable, outperforming the 60-second count. For children with raised respiratory rates the 20-breath version of the Once-per-Breath method is faster, so it is a more suitable option where health workers are under time pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chamberlain, Joseph W.
I wish Marcia Neugebauer the best of luck as she assumes the job of Editor in Chief of Reviews of Geophysics. I hope she recovers her stolen word “data” (Eos, February 28, p. 129), but I don't hold much hope. She is doomed at the start by using as her authority, Webster's Third New International Dictionary of the English Language, Unabridged, which often seems to have been written by Humpty Dumpty, who insisted that a word could mean whatever the master chooses it to mean.Old-timers will recall the ruckus raised by purists when the Third first appeared in 1961. Take the word “data” (but not in Henny Youngman's “please” sense that Neugebauer finds deplorable): The Third already acknowledged that “data” is often used as a singular noun, and the recently issued Ninth Webster's Collegiate, which is the most recent version still based on the Third, goes the remaining distance and accepts this wide current usage as being correct. As far as Neugebauer's complaint is concerned, namely that “computer modelers … have started using ‘data’ for their products,” the Third gives as definition b(2), “detailed information of any kind.” You can't fight Humpty Dumpty.I wish Marcia Neugebauer the best of luck as she assumes the job of Editor in Chief of Reviews of Geophysics. I hope she recovers her stolen word “data” (Eos, February 28, p. 129), but I don't hold much hope. She is doomed at the start by using as her authority, Webster's Third New International Dictionary of the English Language, Unabridged, which often seems to have been written by Humpty Dumpty, who insisted that a word could mean whatever the master chooses it to mean.Old-timers will recall the ruckus raised by purists when the Third first appeared in 1961. Take the word “data” (but not in Henny Youngman's “please” sense that Neugebauer finds deplorable): The Third already acknowledged that “data” is often used as a singular noun, and the recently issued Ninth Webster's Collegiate, which is the most recent version still based on the Third, goes the remaining distance and accepts this wide current usage as being correct. As far as Neugebauer's complaint is concerned, namely that “computer modelers … have started using ‘data’ for their products,” the Third gives as definition b(2), “detailed information of any kind.” You can't fight Humpty Dumpty.
Status Report for the Hypervelocity Free-Flight Aerodynamic Facility
NASA Technical Reports Server (NTRS)
Cornelison, Charles J.; Arnold, James O. (Technical Monitor)
1997-01-01
The Hypervelocity Free-Flight Aerodynamic Facility, located at Ames Research Center, is NASA's only aeroballistic facility. During 1997, its model imaging and time history recording systems were the focus of a major refurbishment effort. Specifically the model detection, spark gap (light source); Kerr cell (high speed shuttering); and interval timer sub-systems were inspected, repaired, modified or replaced as required. These refurbishment efforts have fully restored the HFFAF's capabilities to a much better condition, comparable to what it was 15 years ago. Details of this refurbishment effort along with a brief discussion of future upgrade plans are presented.
Communication Facility EMP Assessment. Sanitized
1979-03-30
IMP Conisequently, omlw the sensitive teiipoots awst dirtittly ipterfacirg witp. the Penetristmiq ies pave been trest*4. I n pa rti cula r the iq,; 1...tramsfermer secedary to the p r filter ifpvt terminals. 16 -_ J a SW * p * A~b. .0 -1 p C c. 17S S 0, c) C 0 E ) ’ 0 t - I *N 0 ( >.> - - Cm7...Overhead Prson "tr cetalSt p 2ec Pamosr 5.0 cam FiueAI2 In5pwrbidn ie r .0 Ia oun s r - ~ -- ----- The timer room contains a 4ml lete equiPmelt
Evaluation of Swift Start TCP in Long-Delay Environment
NASA Technical Reports Server (NTRS)
Lawas-Grodek, Frances J.; Tran, Diepchi T.
2004-01-01
This report presents the test results of the Swift Start algorithm in single-flow and multiple-flow testbeds under the effects of high propagation delays, various slow bottlenecks, and small queue sizes. Although this algorithm estimates capacity and implements packet pacing, the findings were that in a heavily congested link, the Swift Start algorithm will not be applicable. The reason is that the bottleneck estimation is falsely influenced by timeouts induced by retransmissions and the expiration of delayed acknowledgment (ACK) timers, thus causing the modified Swift Start code to fall back to regular transmission control protocol (TCP).
Using the Wiimote in Introductory Physics Experiments
NASA Astrophysics Data System (ADS)
Ochoa, Romulo; Rooney, Frank G.; Somers, William J.
2011-01-01
The Wii is a very popular gaming console. An important component of its appeal is the ease of use of its remote controller, popularly known as a Wiimote. This simple-looking but powerful device has a three-axis accelerometer and communicates with the console via Bluetooth protocol. We present two experiments that demonstrate the feasibility of using the Wiimote in introductory physics experiments. The linear dependence of centripetal acceleration on the radial distance at constant angular velocity is verified and compared with data obtained using photogate timers. A second application to simple harmonic oscillators tests the capabilities of the Wiimote to measure variable accelerations.
NASA Technical Reports Server (NTRS)
2004-01-01
Topics include: Embedded Heaters for Joining or Separating Plastic Parts; Curing Composite Materials Using Lower-Energy Electron Beams; Aluminum-Alloy-Matrix/Alumina-Reinforcement Composites; Fibrous-Ceramic/Aerogel Composite Insulating Tiles; Urethane/Silicone Adhesives for Bonding Flexing Metal Parts; Scalable Architecture for Multihop Wireless ad Hoc Networks; Improved Thermoplastic/Iron-Particle Transformer Cores; Cooperative Lander-Surface/Aerial Microflyer Missions for Mars Exploration Dual-Frequency Airborne Scanning Rain Radar Antenna System Eight-Channel Continuous Timer Reduction of Phase Ambiguity in an Offset-QPSK Receiver Ambient-Light-Canceling Camera Using Subtraction of Frames Lightweight, Flexible, Thin, Integrated Solar-Power Packs Windows(Registered Trademark)-Based Software Models Cyclic Oxidation Behavior Software for Analyzing Sequences of Flow-Related Images Improved Ball-and-Socket Docking Mechanism Two-Stage Solenoid Ordered Nanostructures Made Using Chaperonin Polypeptides Low-Temperature Plasma Functionalization of Carbon Nanotubes Improved Cryostat for Cooling a Wide Panel Current Pulses Momentarily Enhance Thermoelectric Cooling Hand-Held Color Meters Based on Interference Filters Calculating Mass Diffusion in High-Pressure Binary Fluids Fresnel Lenses for Wide-Aperture Optical Receivers Increasing Accuracy in Computed Inviscid Boundary Conditions Higher-Order Finite Elements for Computing Thermal Radiation Radar for Monitoring Hurricanes from Geostationary Orbit Time-Transfer System for Two Orbiting Spacecraft
An Electronic Worker Service System of the Pig House Based on ATmega16
NASA Astrophysics Data System (ADS)
Li, Liu-An; Jin, Tian-Ming; Yu, Ya-Ping; Zhang, Guo-Qiang; Hong, Tao
Pork is very important for people in daily life. Quality of livestock environment is closely related to the growth of animals. To improve environmental quality, the paper designed an electronic worker service system of the pig house based on ATmega16, which consisted of 6 detection modules, wireless data collecting, GSM, time circuit, display, anti-th alarm and music player, etc. A small LAN was constructed by wireless transceiver module to test and collect data of temperature, humidity and harmful gas concentration in the pig house. If one detection point exists that harmful pollutant gases concentration exceeds the standard value, GSM module took a message for livestock farmers, so that farmers can promptly arrive at the pig house to ventilate or deal with manure in the pig house, which can effectively prevent from bad things. Time of pyroelectric detector deployment can be freely set, and intrusion information was timely sent to the users. The anti-th alarm function was achieved by the auxiliary light. The music playing module is open by timer module in order to soothing pigs' life state. All are suitable for small farms and can save human resources.
Position Paper - pFLogger: The Parallel Fortran Logging framework for HPC Applications
NASA Technical Reports Server (NTRS)
Clune, Thomas L.; Cruz, Carlos A.
2017-01-01
In the context of high performance computing (HPC), software investments in support of text-based diagnostics, which monitor a running application, are typically limited compared to those for other types of IO. Examples of such diagnostics include reiteration of configuration parameters, progress indicators, simple metrics (e.g., mass conservation, convergence of solvers, etc.), and timers. To some degree, this difference in priority is justifiable as other forms of output are the primary products of a scientific model and, due to their large data volume, much more likely to be a significant performance concern. In contrast, text-based diagnostic content is generally not shared beyond the individual or group running an application and is most often used to troubleshoot when something goes wrong. We suggest that a more systematic approach enabled by a logging facility (or logger) similar to those routinely used by many communities would provide significant value to complex scientific applications. In the context of high-performance computing, an appropriate logger would provide specialized support for distributed and shared-memory parallelism and have low performance overhead. In this paper, we present our prototype implementation of pFlogger a parallel Fortran-based logging framework, and assess its suitability for use in a complex scientific application.
POSITION PAPER - pFLogger: The Parallel Fortran Logging Framework for HPC Applications
NASA Technical Reports Server (NTRS)
Clune, Thomas L.; Cruz, Carlos A.
2017-01-01
In the context of high performance computing (HPC), software investments in support of text-based diagnostics, which monitor a running application, are typically limited compared to those for other types of IO. Examples of such diagnostics include reiteration of configuration parameters, progress indicators, simple metrics (e.g., mass conservation, convergence of solvers, etc.), and timers. To some degree, this difference in priority is justifiable as other forms of output are the primary products of a scientific model and, due to their large data volume, much more likely to be a significant performance concern. In contrast, text-based diagnostic content is generally not shared beyond the individual or group running an application and is most often used to troubleshoot when something goes wrong. We suggest that a more systematic approach enabled by a logging facility (or 'logger') similar to those routinely used by many communities would provide significant value to complex scientific applications. In the context of high-performance computing, an appropriate logger would provide specialized support for distributed and shared-memory parallelism and have low performance overhead. In this paper, we present our prototype implementation of pFlogger - a parallel Fortran-based logging framework, and assess its suitability for use in a complex scientific application.
Rendigs, Richard R.; Anderson, Roger Y.; Xu, Jingping; Davis, Raymond E.; Bergeron, Emile M.
2009-01-01
This manual illustrates the development of a programmable instrument designed to deploy a series of wafer-shaped discs (partitions) into the collection tube of a sediment trap in various aquatic environments. These hydrodynamically shaped discs are deployed at discrete time intervals from the Intervalometer and provide markers that delineate time intervals within the sediments that accumulate in the collection tube. The timer and mechanical system are lodged in an air-filled, water-tight pressure housing that is vertically hung within the confines of a cone-shaped sediment trap. The instrumentation has been operationally pressure tested to an equivalent water depth of approximately 1 km. Flaws discovered during extensive laboratory and pressure testing resulted in the implementation of several mechanical modifications (such as a redesign of the rotor and the discs) that improved the operation of the rotor assembly as well as the release of discs through the end cap. These results also identified a preferred azimuth placement of the rotor disc relative to the drop hole of the end cap. In the initial field trial, five sediment traps and coupled Intervalometers were attached to moored arrays and deployed at two sites off the coast of Southern California for approximately 8 months. Each of the instruments released 18 discs at the programmed 10 day intervals, except one unit, which experienced a malfunction after approximately 4 months. Most of the discs oriented in a near-horizontal position upon the surface of the sediment in the collection tubes. Sampling of the sediments for geochemical analyses was improved by these clearly defined markers, which indicated the changes in the flux and nature of sediments accumulated during the deployment period of each sediment trap.
Social processes explaining the benefits of Al-Anon participation.
Timko, Christine; Halvorson, Max; Kong, Calvin; Moos, Rudolf H
2015-12-01
This study examined social processes of support, goal direction, provision of role models, and involvement in rewarding activities to explain benefits of participating in Al-Anon, a 12-step mutual-help program for people concerned about another person's substance use. Newcomers to Al-Anon were studied at baseline and 6 months later, at which time they were identified as having either sustained attendance or dropped out. Among both newcomers and established Al-Anon members ("old-timers"), we also used number of Al-Anon meetings attended during follow-up to indicate extent of participation. Social processes significantly mediated newcomers' sustained attendance status versus dropped out and outcomes of Al-Anon in the areas of life context (e.g., better quality of life, better able to handle problems due to the drinker), improved positive symptoms (e.g., higher self-esteem, more hopeful), and decreased negative symptoms (e.g., less abuse, less depressed). Social processes also significantly mediated newcomers' number of meetings attended and outcomes. However, among old-timers, Al-Anon attendance was not associated with outcomes, so the potential mediating role of social processes could not be examined, but social processes were associated with outcomes. Findings add to the growing body of work identifying mechanisms by which 12-step groups are effective, by showing that bonding, goal direction, and access to peers in recovery and rewarding pursuits help to explain associations between sustained Al-Anon participation among newcomers and improvements on key concerns of Al-Anon attendees. Al-Anon is free of charge and widely available, making it a potentially cost-effective public health resource for help alleviating negative consequences of concern about another's addiction. (c) 2016 APA, all rights reserved).
Shahrill, Masitah; Mundia, Lawrence
2014-01-01
Using the Adolescent Coping Scale, ACS (Frydenberg & Lewis, 1993) we surveyed 45 randomly selected foreign adolescents in Australian schools. The coping strategies used most by the participants were: focus on solving the problem; seeking relaxing diversions; focusing on the positive; seeking social support; worry; seeking to belong; investing in close friends; wishful thinking; and keep to self (Table 4). With regard to coping styles, the most widely used was the productive coping followed by non-productive coping while the least used style was reference to others (Table 4). In terms of both genders the four coping strategies used most often were: work hard to achieve; seeking relaxing diversions; focus on solving the problem; and focus on the positive (Table 5). The most noticeable gender difference was the use of the physical recreation coping strategy in which male students engaged more (Fig 1). The usage of four coping strategies (solving problem; work hard; focus on positive; and social support) was higher for students who have been away from family more than once as compared to those who have been away once only while the usage of seeking relaxing diversions was higher for the first timers (Table 6). No significant differences were obtained on the sample’s performance on the ACS subscales by gender (Table 7), frequency of leaving own country (Table 8), country of origin (Table 9), and length of stay in Australia (Table 11). However, foundation students scored significantly higher on the reference to others variable than their secondary school peers (Table 10). We recommended counseling for students with high support needs and further large-scale mixed-methods research to gain additional insights. PMID:24373267
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, Benjamin S.
The Futility package contains the following: 1) Definition of the size of integers and real numbers; 2) A generic Unit test harness; 3) Definitions for some basic extensions to the Fortran language: arbitrary length strings, a parameter list construct, exception handlers, command line processor, timers; 4) Geometry definitions: point, line, plane, box, cylinder, polyhedron; 5) File wrapper functions: standard Fortran input/output files, Fortran binary files, HDF5 files; 6) Parallel wrapper functions: MPI, and Open MP abstraction layers, partitioning algorithms; 7) Math utilities: BLAS, Matrix and Vector definitions, Linear Solver methods and wrappers for other TPLs (PETSC, MKL, etc), preconditioner classes;more » 8) Misc: random number generator, water saturation properties, sorting algorithms.« less
Hu, Wenfeng; Liu, Lu; Feng, Gang
2016-09-02
This paper addresses the output consensus problem of heterogeneous linear multi-agent systems. We first propose a novel distributed event-triggered control scheme. It is shown that, with the proposed control scheme, the output consensus problem can be solved if two matrix equations are satisfied. Then, we further propose a novel self-triggered control scheme, with which continuous monitoring is avoided. By introducing a fixed timer into both event- and self-triggered control schemes, Zeno behavior can be ruled out for each agent. The effectiveness of the event- and self-triggered control schemes is illustrated by an example.
A temperature controller board for the ARC controller
NASA Astrophysics Data System (ADS)
Tulloch, Simon
2016-07-01
A high-performance temperature controller board has been produced for the ARC Generation-3 CCD controller. It contains two 9W temperature servo loops and four temperature input channels and is fully programmable via the ARC API and OWL data acquisition program. PI-loop control is implemented in an on-board micro. Both diode and RTD sensors can be used. Control and telemetry data is sent via the ARC backplane although a USB-2 interface is also available. Further functionality includes hardware timers and high current drivers for external shutters and calibration LEDs, an LCD display, a parallel i/o port, a pressure sensor interface and an uncommitted analogue telemetry input.
A Timer for Synchronous Digital Systems
NASA Technical Reports Server (NTRS)
McKenney, Elizabeth; Irwin, Philip
2003-01-01
The Real-Time Interferometer Control Systems Testbed (RICST) timing board is a VersaModule Eurocard (VME)-based board that can generate up to 16 simultaneous, phase-locked timing signals at a rate defined by the user. It can also generate all seven VME interrupt requests (IRQs). The RICST timing board is suitable mainly for robotic, aerospace, and real-time applications. Several circuit boards on the market are capable of generating periodic IRQs. Most are associated with Global Positioning System (GPS) receivers and Inter Range Instrumentation Group (IRIG) time-code generators, whereas this board uses either an internal VME clock or an externally generated clock signal to synchronize multiple components of the system. The primary advantage of this board is that there is no discernible jitter in the output clock waveforms because the signals are divided down from a high-frequency clock signal instead of being phase-locked from a lower frequency. The primary disadvantage to this board, relative to other periodic-IRQ-generating boards, is that it is more difficult to synchronize the system to wall clock time.
Gut microbiota modulation of chemotherapy efficacy and toxicity.
Alexander, James L; Wilson, Ian D; Teare, Julian; Marchesi, Julian R; Nicholson, Jeremy K; Kinross, James M
2017-06-01
Evidence is growing that the gut microbiota modulates the host response to chemotherapeutic drugs, with three main clinical outcomes: facilitation of drug efficacy; abrogation and compromise of anticancer effects; and mediation of toxicity. The implication is that gut microbiota are critical to the development of personalized cancer treatment strategies and, therefore, a greater insight into prokaryotic co-metabolism of chemotherapeutic drugs is now required. This thinking is based on evidence from human, animal and in vitro studies that gut bacteria are intimately linked to the pharmacological effects of chemotherapies (5-fluorouracil, cyclophosphamide, irinotecan, oxaliplatin, gemcitabine, methotrexate) and novel targeted immunotherapies such as anti-PD-L1 and anti-CLTA-4 therapies. The gut microbiota modulate these agents through key mechanisms, structured as the 'TIMER' mechanistic framework: Translocation, Immunomodulation, Metabolism, Enzymatic degradation, and Reduced diversity and ecological variation. The gut microbiota can now, therefore, be targeted to improve efficacy and reduce the toxicity of current chemotherapy agents. In this Review, we outline the implications of pharmacomicrobiomics in cancer therapeutics and define how the microbiota might be modified in clinical practice to improve efficacy and reduce the toxic burden of these compounds.
Autonomous locomotion of capsule endoscope in gastrointestinal tract.
Yang, Sungwook; Park, Kitae; Kim, Jinseok; Kim, Tae Song; Cho, Il-Joo; Yoon, Eui-Sung
2011-01-01
Autonomous locomotion in gastrointestinal (GI) tracts is achieved with a paddling-based capsule endoscope. For this, a miniaturized encoder module was developed utilizing a MEMS fabrication technology to monitor the position of paddles. The integrated encoder module yielded the high resolution of 0.0025 mm in the linear motion of the paddles. In addition, a PID control method was implemented on a DSP to control the stroke of the paddles accurately. As a result, the average accuracy and the standard deviation were measured to be 0.037 mm and 0.025 mm by a laser position sensor for the repetitive measurements. The locomotive performance was evaluated via ex-vivo tests according to various strokes in paddling. In an in-vivo experiment with a living pig, the locomotion speed was improved by 58% compared with the previous control method relying on a given timer value for reciprocation of the paddles. Finally, the integrated encoder module and the control system allow consistent paddling during locomotion even under loads in GI tract. It provides the autonomous locomotion without intervention in monitoring and controlling the capsule endoscope.
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
Recent Developments in Balloon Support Instrumentation at TIFR Balloon Facility, Hyderabad.
NASA Astrophysics Data System (ADS)
Vasudevan, Rajagopalan
2012-07-01
The Balloon Facility of Tata Institute of Fundamental Research has been conducting stratospheric balloon flights regularly for various experiments in Space Astronomy and Atmospheric Sciences. A continuous improvement in Balloon flight Support instrumentation by the Control Instrumentation Group to keep in space with the growing complexities of the scientific payloads have contributed to the total success of balloon flights conducted recently. Recent improvements in display of Balloon position during balloon flight by showing on real time the balloon GPS position against Google TM maps is of immense help in selecting the right spot for payload landing and safe recovery . For further speeding up the payload recovery process, a new GPS-GSM payload system has been developed which gives SMS of the payload position information to the recovery team on their cell phones. On parallel footing, a new GPS- VHF system has been developed using GPS and Radio Modems for Balloon Tracking and also for obtaining the payload impact point. On the Telecommand side, a single board Telecommand/ Timer weighing less than 2 Kg has been specially developed for use in the mesosphere balloon test flight. The interference on the existing Short Range Telemetry System has been eliminated by introducing a Band Pass Filter and LNA in the Receiving system of the modules, thereby enhancing its reliability. In this paper , we present the details of the above mentioned developments.
An Evaluation of the Performance Diagnostic Checklist-Human Services (PDC-HS) Across Domains.
Wilder, David A; Lipschultz, Joshua; Gehrman, Chana
2018-06-01
The Performance Diagnostic Checklist-Human Services (PDC-HS) is an informant-based tool designed to assess the environmental variables that contribute to poor employee performance in human service settings. Although the PDC-HS has been shown to effectively identify variables contributing to problematic performance, interventions based on only two of the four PDC-HS domains have been evaluated to date. In addition, the extent to which PDC-HS-indicated interventions are more effective than nonindicated interventions for two domains remains unclear. In the current study, we administered the PDC-HS to supervisors to assess the variables contributing to infrequent teaching of verbal operants and use of a timer by therapists at a center-based autism treatment program. Each of the four PDC-HS domains was identified as contributing to poor performance for at least one therapist. We then evaluated PDC-HS-indicated interventions for each domain. In addition, to assess the predictive validity of the tool, we evaluated various nonindicated interventions prior to implementing a PDC-HS-indicated intervention for two of the four domains. Results suggest that the PDC-HS-indicated interventions were effective across all four domains and were more effective than the nonindicated interventions for the two domains for which they were evaluated. Results are discussed in terms of the utility of the PDC-HS to identify appropriate interventions to manage therapist performance in human service settings.
Ground-based demonstration of the European Laser Timing (ELT) experiment.
Schreiber, Karl Ulrich; Prochazka, Ivan; Lauber, Pierre; Hugentobler, Urs; Schäfer, Wolfgang; Cacciapuoti, Luigi; Nasca, Rosario
2010-03-01
The development of techniques for the comparison of distant clocks and for the distribution of stable and accurate time scales has important applications in metrology and fundamental physics research. Additionally, the rapid progress of frequency standards in the optical domain is presently demanding additional efforts for improving the performances of existing time and frequency transfer links. Present clock comparison systems in the microwave domain are based on GPS and two-way satellite time and frequency transfer (TWSTFT). European Laser Timing (ELT) is an optical link presently under study in the frame of the ESA mission Atomic Clock Ensemble in Space (ACES). The on-board hardware for ELT consists of a corner cube retro-reflector (CCR), a single-photon avalanche diode (SPAD), and an event timer board connected to the ACES time scale. Light pulses fired toward ACES by a laser ranging station will be detected by the SPAD diode and time tagged in the ACES time scale. At the same time, the CCR will re-direct the laser pulse toward the ground station providing precise ranging information. We have carried out a ground-based feasibility study at the Geodetic Observatory Wettzell. By using ordinary satellites with laser reflectors and providing a second independent detection port and laser pulse timing unit with an independent time scale, it is possible to evaluate many aspects of the proposed time transfer link before the ACES launch.
Fall prevention modulates decisional saccadic behavior in aging.
Coubard, Olivier A
2012-01-01
As society ages and frequency of falls increases in older adults, counteracting motor decline is a challenging issue for developed countries. Physical activity based on aerobic and strength training as well as motor activity based on skill learning both help benefit balance and reduce the risk of falls, as assessed by clinical or laboratory measures. However, how such programs influence motor control is a neglected issue. This study examined the effects of fall prevention (FP) training on saccadic control in older adults. Saccades were recorded in 12 participants aged 64-91 years before and after 2.5 months training in FP. Traditional analysis of saccade timing and dynamics was performed together with a quantitative analysis using the LATER model, enabling us to examine the underlying motor control processes. Results indicated that FP reduced the rate of anticipatory and express saccades in inappropriate directions and enhanced that of express saccades in the appropriate direction, resulting in decreased latency and higher left-right symmetry of motor responses. FP reduced within-participant variability of saccade duration, amplitude, and peak velocity. LATER analysis suggested that FP modulates decisional thresholds, extending our knowledge of motor training influence on central motor control. We introduce the Threshold Interval Modulation with Early Release-Rate of rIse Deviation with Early Release (TIMER-RIDER) model to account for the results.
An on-time power-aware scheduling scheme for medical sensor SoC-based WBAN systems.
Hwang, Tae-Ho; Kim, Dong-Sun; Kim, Jung-Guk
2012-12-27
The focus of many leading technologies in the field of medical sensor systems is on low power consumption and robust data transmission. For example, the implantable cardioverter-defibrillator (ICD), which is used to maintain the heart in a healthy state, requires a reliable wireless communication scheme with an extremely low duty-cycle, high bit rate, and energy-efficient media access protocols. Because such devices must be sustained for over 5 years without access to battery replacement, they must be designed to have extremely low power consumption in sleep mode. Here, an on-time, energy-efficient scheduling scheme is proposed that performs power adjustments to minimize the sleep-mode current. The novelty of this scheduler is that it increases the determinacy of power adjustment and the predictability of scheduling by employing non-pre-emptible dual priority scheduling. This predictable scheduling also guarantees the punctuality of important periodic tasks based on their serialization, by using their worst case execution time) and the power consumption optimization. The scheduler was embedded into a system on chip (SoC) developed to support the wireless body area network-a wakeup-radio and wakeup-timer for implantable medical devices. This scheduling system is validated by the experimental results of its performance when used with life-time extensions of ICD devices.
An On-Time Power-Aware Scheduling Scheme for Medical Sensor SoC-Based WBAN Systems
Hwang, Tae-Ho; Kim, Dong-Sun; Kim, Jung-Guk
2013-01-01
The focus of many leading technologies in the field of medical sensor systems is on low power consumption and robust data transmission. For example, the implantable cardioverter-defibrillator (ICD), which is used to maintain the heart in a healthy state, requires a reliable wireless communication scheme with an extremely low duty-cycle, high bit rate, and energy-efficient media access protocols. Because such devices must be sustained for over 5 years without access to battery replacement, they must be designed to have extremely low power consumption in sleep mode. Here, an on-time, energy-efficient scheduling scheme is proposed that performs power adjustments to minimize the sleep-mode current. The novelty of this scheduler is that it increases the determinacy of power adjustment and the predictability of scheduling by employing non-pre-emptible dual priority scheduling. This predictable scheduling also guarantees the punctuality of important periodic tasks based on their serialization, by using their worst case execution time) and the power consumption optimization. The scheduler was embedded into a system on chip (SoC) developed to support the wireless body area network—a wakeup-radio and wakeup-timer for implantable medical devices. This scheduling system is validated by the experimental results of its performance when used with life-time extensions of ICD devices. PMID:23271602
Using hacked point and shoot cameras for time-lapse snow cover monitoring in an Alpine valley
NASA Astrophysics Data System (ADS)
Weijs, S. V.; Diebold, M.; Mutzner, R.; Golay, J. R.; Parlange, M. B.
2012-04-01
In Alpine environments, monitoring snow cover is essential get insight in the hydrological processes and water balance. Although measurement techniques based on LIDAR are available, their cost is often a restricting factor. In this research, an experiment was done using a distributed array of cheap consumer cameras to get insight in the spatio-temporal evolution of snowpack. Two experiments are planned. The first involves the measurement of eolic snow transport around a hill, to validate a snow saltation model. The second monitors the snowmelt during the melting season, which can then be combined with data from a wireless network of meteorological stations and discharge measurements at the outlet of the catchment. The poster describes the hardware and software setup, based on an external timer circuit and CHDK, the Canon Hack Development Kit. This latter is a flexible and developing software package, released under a GPL license. It was developed by hackers that reverse engineered the firmware of the camera and added extra functionality such as raw image output, more full control of the camera, external trigger and motion detection, and scripting. These features make it a great tool for geosciences. Possible other applications involve aerial stereo photography, monitoring vegetation response. We are interested in sharing experiences and brainstorming about new applications. Bring your camera!
A Wide Range Temperature Sensor Using SOI Technology
NASA Technical Reports Server (NTRS)
Patterson, Richard L.; Elbuluk, Malik E.; Hammoud, Ahmad
2009-01-01
Silicon-on-insulator (SOI) technology is becoming widely used in integrated circuit chips for its advantages over the conventional silicon counterpart. The decrease in leakage current combined with lower power consumption allows electronics to operate in a broader temperature range. This paper describes the performance of an SOIbased temperature sensor under extreme temperatures and thermal cycling. The sensor comprised of a temperature-to-frequency relaxation oscillator circuit utilizing an SOI precision timer chip. The circuit was evaluated under extreme temperature exposure and thermal cycling between -190 C and +210 C. The results indicate that the sensor performed well over the entire test temperature range and it was able to re-start at extreme temperatures.
A closed-loop automatic control system for high-intensity acoustic test systems.
NASA Technical Reports Server (NTRS)
Slusser, R. A.
1973-01-01
Description of an automatic control system for high-intensity acoustic tests in reverberation chambers. Working in 14 one-third-octave bands from 50 to 1000 Hz, the desired sound pressure levels are set into the memory in the control system before the test. The control system then increases the sound pressure level in the reverberation chamber gradually in each of the one-third-octave bands until the level set in the memory is reached. This level is then maintained for the duration of the test. Additional features of the system are overtest protection, the capability of 'holding' the spectrum at any time, and the presence of a total test timer.
Miarka, Bianca; Brito, Ciro José; Bello, Fábio Dal; Amtmann, John
2017-10-01
This study compared motor actions and spatiotemporal changes between weight divisions from Ultimate Fighting Championship (UFC™), conducting a practical application for mixed martial arts (MMA) training. For this, we analyzed 2814 rounds of all weight divisions by motor actions and spatiotemporal changes according actions and time of the Keeping distance, Clinch and Groundwork combat phases. We observed differences between weight divisions in the keeping distance on stand-up combat (p≤0.001; with lower time in Featherweight 131.4s and bantamweight 127.9s) clinch without attack (p≤0.001; with higher timer in Flyweight 11.4s and Half-middleweight 12.6s) and groundwork without attack (p≤0.001; with higher timer in Half-middleweight 0.9s). During keeping distance, half-middleweight presented a higher frequency of Head Strikes Landed (p=0.026; 7±8 times) and attempted (p=0.003; 24±22 times). In clinch actions heavyweight present a higher frequency (p≤0.023) of head strike landed (3±7 times) and attempted (4±9 times) and half-middleweight for body strikes (p≤0.023) landed (2±5 times) and attempted (3±5 times). At the last, during groundwork, Bantamweight present a higher frequency (p≤0.036) of head strikes landed (8±10 times) and attempted (10±13 times) body strikes landed (p≤0.044; 3±5 times) and attempted (3±6 times). This study reveals important point to training and provide a challenge applied referential to the conditioning plains. From the weight divisions differences should be aware of the increase in the frequency of distance actions, especially in light and middleweights. On the Ground, bantamweight can focus on striking and grappling actions than others. Copyright © 2017 Elsevier B.V. All rights reserved.
Brinkhus, H B; Klinkenborg, H; Estorf, R; Weber, R
1983-01-01
A new programming language SORCA has been defined and a compiler has been written for Z80-based microcomputer systems with CP/M operating system. The language was developed to control behavioral experiments by external stimuli and by time schedule in real-time. Eight binary hardware input lines are sampled cyclically by the computer and can be used to sense switches, level detectors and other binary information, while 8 binary hardware output lines, that are cyclically updated, can be used to control relays, lamps, generate tones or for other purposes. The typical reaction time (cycle time) of a SORCA-program is 500 microseconds to 1 ms. All functions can be programmed as often as necessary. Included are the basic logic functions, counters, timers, majority gates and other complex functions. Parameters can be given as constants or as a result of a step function or of a random process (with Gaussian or equal distribution). Several tasks can be performed simultaneously. In addition, results of an experiment (e.g., number of reactions or latencies) can be measured and printed out on request or automatically. The language is easy to learn and can also be used for many other control purposes.
Programs to optimize adherence in glaucoma.
Kowing, Dianne; Messer, Dawn; Slagle, Scott; Wasik, Alyon
2010-07-01
This study was designed to raise awareness of the materials, devices, and Internet resources available to improve adherence to use of medications for the treatment of glaucoma and to review new devices under development. A review of current indexed literature and Internet resources was conducted. A variety of educational brochures, pamphlets, and fact sheets promoting adherence to ocular hypotensive medications are available through multiple organizations and are easily accessed and ordered on the Internet. Video and Web-based patient educational tools have been designed to support patient adherence to glaucoma management plans and promote open dialogue between patients and providers. Reminder and recall systems that integrate with office software can be sent to cell phones as well as e-mails and personal digital assistant (PDAs), alerting patients to upcoming appointments and reminding them to instill their drops. Bottle devices with dosing support (timers with audible and visual signals and dispensing aids) and electronic monitoring have been shown to promote adherence. New products currently under development to improve the delivery of medications include nanoparticles, punctal plugs, and contact lenses that release glaucoma medications. Many educational materials, services, Internet resources, and devices are available to optometrists to encourage patient adherence to glaucoma treatment and management. Published by Elsevier Inc.
Redundancy, Self-Motion, and Motor Control
Martin, V.; Scholz, J. P.; Schöner, G.
2011-01-01
Outside the laboratory, human movement typically involves redundant effector systems. How the nervous system selects among the task-equivalent solutions may provide insights into how movement is controlled. We propose a process model of movement generation that accounts for the kinematics of goal-directed pointing movements performed with a redundant arm. The key element is a neuronal dynamics that generates a virtual joint trajectory. This dynamics receives input from a neuronal timer that paces end-effector motion along its path. Within this dynamics, virtual joint velocity vectors that move the end effector are dynamically decoupled from velocity vectors that do not. Moreover, the sensed real joint configuration is coupled back into this neuronal dynamics, updating the virtual trajectory so that it yields to task-equivalent deviations from the dynamic movement plan. Experimental data from participants who perform in the same task setting as the model are compared in detail to the model predictions. We discover that joint velocities contain a substantial amount of self-motion that does not move the end effector. This is caused by the low impedance of muscle joint systems and by coupling among muscle joint systems due to multiarticulatory muscles. Back-coupling amplifies the induced control errors. We establish a link between the amount of self-motion and how curved the end-effector path is. We show that models in which an inverse dynamics cancels interaction torques predict too little self-motion and too straight end-effector paths. PMID:19718817
High resolution digital delay timer
Martin, Albert D.
1988-01-01
Method and apparatus are provided for generating an output pulse following a trigger pulse at a time delay interval preset with a resolution which is high relative to a low resolution available from supplied clock pulses. A first lumped constant delay (20) provides a first output signal (24) at predetermined interpolation intervals corresponding to the desired high resolution time interval. Latching circuits (26, 28) latch the high resolution data (24) to form a first synchronizing data set (60). A selected time interval has been preset to internal counters (142, 146, 154) and corrected for circuit propagation delay times having the same order of magnitude as the desired high resolution. Internal system clock pulses (32, 34) count down the counters to generate an internal pulse delayed by an interval which is functionally related to the preset time interval. A second LCD (184) corrects the internal signal with the high resolution time delay. A second internal pulse is then applied to a third LCD (74) to generate a second set of synchronizing data (76) which is complementary with the first set of synchronizing data (60) for presentation to logic circuits (64). The logic circuits (64) further delay the internal output signal (72) to obtain a proper phase relationship of an output signal (80) with the internal pulses (32, 34). The final delayed output signal (80) thereafter enables the output pulse generator (82) to produce the desired output pulse (84) at the preset time delay interval following input of the trigger pulse (10, 12).
Design and performance of a respiratory amplitude gating device for PET/CT imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang Guoping; Chang Tingting; Clark, John W. Jr.
2010-04-15
Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order tomore » monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.« less
Boiso, Irene; Veiga, Anna; Edwards, Robert G
2002-01-01
Knowledge of the nature of embryo growth, and the handling and scoring of quality in human embryos are significant aspects for embryologists in IVF clinics. This review describes the formation, growth and maturation of human oocytes, many aspects of fertilization in vitro, embryonic transcription during preimplantation stages, and the formation of polarities, timing controls, role of mitochondria and functions of endocrine and paracrine systems. Modern concepts are fully discussed, together with their significance in the practice of IVF. This knowledge is essential for the correct clinical care of human embryos growing in vitro, especially in view of their uncharacteristic tendency to vary widely in implantation potential. Underlying causes of such variation have not been identified. Stringent tests must be enforced to ensure human embryos develop under optimal conditions, and are scored for quality using the most advanced techniques. Optimal methods of culture are described, including methods such as co-culture introduced to improve embryo quality but less important today. Detailed attention is given to quality as assessed from embryonic characteristics determined by timers, polarities, disturbed embryo growth and anomalous cell cycles. Methods for classification are described. Approaches to single embryo transfers are described, including the use of sequential media to produce high-quality blastocysts. These approaches, and others involved in surgical methods to remove fragments, transfer ooplasm or utilize newer approaches such as preimplantation diagnosis of chromosomal complements in embryos are covered. New outlooks in this field are summarized.
Circadian Timing in the Lung; A Specific Role for Bronchiolar Epithelial Cells
Gibbs, J. E.; Beesley, S.; Plumb, J.; Singh, D.; Farrow, S.; Ray, D. W.; Loudon, A. S. I.
2015-01-01
In addition to the core circadian oscillator, located within the suprachiasmatic nucleus, numerous peripheral tissues possess self-sustaining circadian timers. In vivo these are entrained and temporally synchronized by signals conveyed from the core oscillator. In the present study, we examine circadian timing in the lung, determine the cellular localization of core clock proteins in both mouse and human lung tissue, and establish the effects of glucocorticoids (widely used in the treatment of asthma) on the pulmonary clock. Using organotypic lung slices prepared from transgenic mPER2::Luc mice, luciferase levels, which report PER2 expression, were measured over a number of days. We demonstrate a robust circadian rhythm in the mouse lung that is responsive to glucocorticoids. Immunohistochemical techniques were used to localize specific expression of core clock proteins, and the glucocorticoid receptor, to the epithelial cells lining the bronchioles in both mouse and human lung. In the mouse, these were established to be Clara cells. Murine Clara cells retained circadian rhythmicity when grown as a pure population in culture. Furthermore, selective ablation of Clara cells resulted in the loss of circadian rhythm in lung slices, demonstrating the importance of this cell type in maintaining overall pulmonary circadian rhythmicity. In summary, we demonstrate that Clara cells are critical for maintaining coherent circadian oscillations in lung tissue. Their coexpression of the glucocorticoid receptor and core clock components establishes them as a likely interface between humoral suprachiasmatic nucleus output and circadian lung physiology. PMID:18787022
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krieger, G L
1976-06-01
W (the average energy to form an ion pair) for 5.4 MeV /sup 241/Am alpha particles in a Rossi-type tissue equivalent (T.E.) gas, argon and methane was determined to an accuracy better than 0.2% using a new automated data handling system. A vibrating reed electrometer and current digitizer were used to measure the current produced by completely stopping the alpha particles in a large cylindrical ionization chamber. A multichannel analyzer, operating in a slow multiscalar mode, was used to store pulses from the current digitizer. The dwell time, on the order of 60 minutes per channel, was selected with anmore » external timer gate. Current measurements were made at reduced pressures (approximately 200 torr) to reduce ion-recombination. The average current, over many repeated measurements, was compared to the current produced in nitrogen and its previously published W-value of 36.39 +- 0.04 eV/ion pair. The resulting W-values were (in eV/ion pair): 26.29 +- 0.05 for argon, 29.08 +- 0.03 for methane and 30.72 +- 0.04 for T.E. gas, which had an analyzed composition of 64.6% methane, 32.4% CO/sub 2/, and 2.7% nitrogen. Although the methane and argon values agree within 0.1% with previously published values, the value for T.E. is 1.2% lower than the single previously reported value.« less
Clinical assessment of infant colour at delivery
O'Donnell, Colm P F; Kamlin, C Omar F; Davis, Peter G; Carlin, John B; Morley, Colin J
2007-01-01
Objective Use of video recordings of newborn infants to determine: (1) if clinicians agreed whether infants were pink; and (2) the pulse oximeter oxygen saturation (Spo2) at which infants first looked pink. Methods Selected clips from video recordings of infants taken immediately after delivery were shown to medical and nursing staff. The infants received varying degrees of resuscitation (including none) and were monitored with pulse oximetry. The oximeter readings were obscured to observers but known to the investigators. A timer was visible and the sound was inaudible. The observers were asked to indicate whether each infant was pink at the beginning, became pink during the clip, or was never pink. If adjudged to turn pink during the clip, observers recorded the time this occurred and the corresponding Spo2 was determined. Results 27 clinicians assessed videos of 20 infants (mean (SD) gestation 31(4) weeks). One infant (5%) was perceived to be pink by all observers. The number of clinicians who thought each of the remaining 19 infants were never pink varied from 1 (4%) to 22 (81%). Observers determined the 10 infants with a maximum Spo2 ⩾95% never pink on 17% (46/270) of occasions. The Spo2 at which individual infants were perceived to turn pink varied from 10% to 100%. Conclusion Among clinicians observing the same videos there was disagreement about whether newborn infants looked pink with wide variation in the Spo2 when they were considered to become pink. PMID:17613535
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati
This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The surveymore » meter measurement results are found to be linear for dose rates below 3500 µSv/hr.« less
Dwarfs and Giants in the local flows of galaxies.
NASA Astrophysics Data System (ADS)
Chernin, A. D.; Emelyanov, N. V.; Karachentsev, I. D.
We use recent Hubble Space Telescope data on nearby dwarf and giant galaxies to study the dynamical structure and evolutionary trends of the local expansion flows of galaxies. It is found that antigravity of dark energy dominates the force field of the flows and makes them expand with acceleration. It also cools the flows and introduces to them the nearly linear velocity-distance relation with the time-rate close to the global Hubble's factor. There are grounds to expect that this is the universal physical regularity that is common not only for the nearby flows we studied here, but also for all the expansion flows of various spatial scales from the 1 Mpc scale and up to the scale of the global cosmological expansion.
Measurement of sound absorption in the air. [data procesing
NASA Technical Reports Server (NTRS)
Meredith, R.; Badavi, F.; Becher, J.
1981-01-01
The large temperature gradient in each section of the resonance tube resulting from the liquid nitrogen coolant necessitated a design modification to the cooling system. A timer and four solenoid valves were installed so that the coolant flow can be reversed periodically. The hardware and software for controlling the analog to digital converter and conversion rate were completed, and the system is operational. A duty cycle control circit was implemented so that on the sixteenth conversion a relay shuts off the vibration exciter used to generate the sound wave. Thus the starting point of each decay curve is exactly known. This information is necessary for evaluating the g digital decay information. The data acquisition and digital decay evaluation programs are described.
Inflight Evaluation of an Acoustic Orientation Instrument
1992-12-01
othoienwma noted. mu wwTI DATA OUT DATA VAUID Figure 11-9. Porn Write or Timor Output Compare E:WU READ DATA M* PORTS A. C. 0 DAT VLI DATA Ill PORT fDATA...9* 9* WATCH DOG TIMER x x X x X X X X X X RS-232 CONVERSION X X x X X X X X RS-232 DB25 CONN. X X X X X X X RESET BUTTON X X X X X X X RS-422/485...calanOs. Tfle b.A.1t-in skivmter and us~ dog timrm, rrnm it the natural dmie fo real tire g’~ t~man and sacung also ca benit fr= it’s feture. frv F68MC is
The role of musical training in emergent and event-based timing.
Baer, L H; Thibodeau, J L N; Gralnick, T M; Li, K Z H; Penhune, V B
2013-01-01
Musical performance is thought to rely predominantly on event-based timing involving a clock-like neural process and an explicit internal representation of the time interval. Some aspects of musical performance may rely on emergent timing, which is established through the optimization of movement kinematics, and can be maintained without reference to any explicit representation of the time interval. We predicted that musical training would have its largest effect on event-based timing, supporting the dissociability of these timing processes and the dominance of event-based timing in musical performance. We compared 22 musicians and 17 non-musicians on the prototypical event-based timing task of finger tapping and on the typically emergently timed task of circle drawing. For each task, participants first responded in synchrony with a metronome (Paced) and then responded at the same rate without the metronome (Unpaced). Analyses of the Unpaced phase revealed that non-musicians were more variable in their inter-response intervals for finger tapping compared to circle drawing. Musicians did not differ between the two tasks. Between groups, non-musicians were more variable than musicians for tapping but not for drawing. We were able to show that the differences were due to less timer variability in musicians on the tapping task. Correlational analyses of movement jerk and inter-response interval variability revealed a negative association for tapping and a positive association for drawing in non-musicians only. These results suggest that musical training affects temporal variability in tapping but not drawing. Additionally, musicians and non-musicians may be employing different movement strategies to maintain accurate timing in the two tasks. These findings add to our understanding of how musical training affects timing and support the dissociability of event-based and emergent timing modes.
NASA Technical Reports Server (NTRS)
2007-01-01
Topics include: Program Merges SAR Data on Terrain and Vegetation Heights; Using G(exp 4)FETs as a Data Router for In-Plane Crossing of Signal Paths; Two Algorithms for Processing Electronic Nose Data; Radiation-Tolerant Dual Data Bus; General-Purpose Front End for Real-Time Data Processing; Nanocomposite Photoelectrochemical Cells; Ultracapacitor-Powered Cordless Drill, Cumulative Timers for Microprocessors; Photocatalytic/Magnetic Composite Particles; Separation and Sealing of a Sample Container Using Brazing; Automated Aerial Refueling Hitches a Ride on AFF; Cobra Probes Containing Replaceable Thermocouples; High-Speed Noninvasive Eye-Tracking System; Detergent-Specific Membrane Protein Crystallization Screens; Evaporation-Cooled Protective Suits for Firefighters; Plasmonic Antenna Coupling for QWIPs; Electronic Tongue Containing Redox and Conductivity Sensors; Improved Heat-Stress Algorithm; A Method of Partly Automated Testing of Software; Rover Wheel-Actuated Tool Interface; and Second-Generation Electronic Nose.
T2L2/Jason-2, first year of processing activities
NASA Astrophysics Data System (ADS)
Exertier, P.
2009-11-01
The T2L2 (Time Transfer by Laser Link) project, developed by CNES and OCA will permit the synchronization of remote ultra stable clocks and the determination of their performances over intercontinental distances. The principle is derived from laser telemetry technology with a dedicated space equipment designed to record arrival time of laser pulses at the satellite. T2L2 was accepted in 2005 to be on board the Jason-2 altimetry satellite. It has been successfully launched from Vandenberg (CA, US) in June 2008. T2L2 acquired the first laser pulses a few days after the launch. First analysis permitted to validate some important characteristics of the instrument such as sensitivity, noise, dynamic, event timer precision and ground to space time stability.
Red fluorescent proteins: advanced imaging applications and future design.
Shcherbakova, Daria M; Subach, Oksana M; Verkhusha, Vladislav V
2012-10-22
In the past few years a large series of the advanced red-shifted fluorescent proteins (RFPs) has been developed. These enhanced RFPs provide new possibilities to study biological processes at the levels ranging from single molecules to whole organisms. Herein the relationship between the properties of the RFPs of different phenotypes and their applications to various imaging techniques are described. Existing and emerging imaging approaches are discussed for conventional RFPs, far-red FPs, RFPs with a large Stokes shift, fluorescent timers, irreversibly photoactivatable and reversibly photoswitchable RFPs. Advantages and limitations of specific RFPs for each technique are presented. Recent progress in understanding the chemical transformations of red chromophores allows the future RFP phenotypes and their respective novel imaging applications to be foreseen. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dale Reed with model in front of M2-F1
1967-03-06
Dale Reed with a model of the M2-F1 in front of the actual lifting body. Reed used the model to show the potential of the lifting bodies. He first flew it into tall grass to test stability and trim, then hand-launched it from buildings for longer flights. Finally, he towed the lifting-body model aloft using a powered model airplane known as the "Mothership." A timer released the model and it glided to a landing. Dale's wife Donna used a 9 mm. camera to film the flights of the model. Its stability as it glided--despite its lack of wings--convinced Milt Thompson and some Flight Research Center engineers including the center director, Paul Bikle, that a piloted lifting body was possible.
Microgravity experiment system utilizing a balloon
NASA Astrophysics Data System (ADS)
Namiki, M.; Ohta, S.; Yamagami, T.; Koma, Y.; Akiyama, H.; Hirosawa, H.; Nishimura, J.
A system for microgravity experiments by using a stratospheric balloon has been planned and developed in ISAS since 1978. A rocket-shaped chamber mounting the experiment apparatus is released from the balloon around 30 km altitude. The microgravity duration is from the release to opening of parachute, controlled by an on-board sequential timer. Test flights were performed in 1980 and in 1981. In September 1983 the first scientific experiment, observing behaviors and brain activities of fishes in the microgravity circumstance, have been successfully carried out. The chamber is specially equipped with movie cameras and subtransmitters, and its release altitude is about 32 km. The microgravity observed inside the chamber is less than 2.9 × 10-3 G during 10 sec. Engineering aspects of the system used in the 1983 experiment are presented.
The simplest chronoscope II: reaction time measured by meterstick versus machine.
Montare, Alberto
2010-12-01
Visual simple reaction time (SRT) scores measured in 31 college students of both sexes by use of the simplest chronoscope methodology (meterstick SRT) were compared to scores obtained by use of an electromechanical multi-choice reaction timer (machine SRT). Four hypotheses were tested. Results indicated that the previous mean value of meterstick SRT was replicated; meterstick SRT was significantly faster than long-standing population estimates of mean SRT; and machine SRT was significantly slower than the same long-standing mean SRT estimates for the population. Also, the mean meterstick SRT of 181 msec. was significantly faster than the mean machine SRT of 294 msec. It was theorized that differential visual information processing occurred such that the dorsal visual stream subserved meterstick SRT; whereas the ventral visual stream subserved machine SRT.
Montare, Alberto
2013-06-01
The three classical Donders' reaction time (RT) tasks (simple, choice, and discriminative RTs) were employed to compare reaction time scores from college students obtained by use of Montare's simplest chronoscope (meterstick) methodology to scores obtained by use of a digital-readout multi-choice reaction timer (machine). Five hypotheses were tested. Simple RT, choice RT, and discriminative RT were faster when obtained by meterstick than by machine. The meterstick method showed higher reliability than the machine method and was less variable. The meterstick method of the simplest chronoscope may help to alleviate the longstanding problems of low reliability and high variability of reaction time performances; while at the same time producing faster performance on Donders' simple, choice and discriminative RT tasks than the machine method.
Change in muzzle velocity due to freezing and water immersion of .22, long rifle, K.F. cartridges.
Jauhari, M; Chatterjee, S M; Ghosh, P K
1975-01-01
A study of change in muzzle velocity due to freezing and water immersion of .22, long rifle, K. F. cartridges has been presented. A statistical criterion has been formulated to ascertain whether or not a cartridge undergoes a change in muzzle velocity due to a particular treatment. The muzzle velocity data of .22, long rifle, K. F. cartridges, obtained by an electronic timer before and after the various treatments, have been analyzed in the light of this criterion. These cartridges have generally been found to suffer considerable loss in muzzle velocity when immersed in water for three weeks and also when immersed in water for three days and simultaneously cooled to 0 degrees C. The forensic significance of this loss in muzzle velocity has been discussed.
Parallel-aware, dedicated job co-scheduling within/across symmetric multiprocessing nodes
Jones, Terry R.; Watson, Pythagoras C.; Tuel, William; Brenner, Larry; ,Caffrey, Patrick; Fier, Jeffrey
2010-10-05
In a parallel computing environment comprising a network of SMP nodes each having at least one processor, a parallel-aware co-scheduling method and system for improving the performance and scalability of a dedicated parallel job having synchronizing collective operations. The method and system uses a global co-scheduler and an operating system kernel dispatcher adapted to coordinate interfering system and daemon activities on a node and across nodes to promote intra-node and inter-node overlap of said interfering system and daemon activities as well as intra-node and inter-node overlap of said synchronizing collective operations. In this manner, the impact of random short-lived interruptions, such as timer-decrement processing and periodic daemon activity, on synchronizing collective operations is minimized on large processor-count SPMD bulk-synchronous programming styles.
The SERTS-97 Rocket Experiment on Study Activity on the Sun: Flight 36.167-GS on 1997 November 18
NASA Technical Reports Server (NTRS)
Swartz, Marvin; Condor, Charles E.; Davila, Joseph M.; Haas, J. Patrick; Jordan, Stuart D.; Linard, David L.; Miko, Joseph J.; Nash, I. Carol; Novello, Joseph; Payne, Leslie J.;
1999-01-01
This paper describes mainly the 1997 version of the Solar EUV Rocket Telescope and Spectrograph (SERTS-97), a scientific experiment that operated on NASA's suborbital rocket flight 36.167-GS. Its function was to study activity on the Sun and to provide a cross calibration for the CDS instrument on the SOHO satellite. The experiment was designed, built, and tested by the Solar Physics Branch of the Laboratory for Astronomy and Solar Physics at the Goddard Space Flight Center (GSFC). Other essential sections of the rocket were built under the management of the Sounding Rockets Program Office. These sections include the electronics, timers, IGN despin, the SPARCS pointing controls, the S-19 flight course correction section, the rocket motors, the telemetry, ORSA, and OGIVE.
Zhao, Shenlong; Li, Yuchen; Yin, Huajie; Liu, Zhouzhou; Luan, Enxiao; Zhao, Feng; Tang, Zhiyong; Liu, Shaoqin
2015-01-01
Microbial fuel cells (MFCs) are able to directly convert about 50 to 90% of energy from oxidation of organic matters in waste to electricity and have great potential application in broad fields such as wastewater treatment. Unfortunately, the power density of the MFCs at present is significantly lower than the theoretical value because of technical limitations including low bacteria loading capacity and difficult electron transfer between the bacteria and the electrode. We reported a three-dimensional (3D) graphene aerogel (GA) decorated with platinum nanoparticles (Pt NPs) as an efficient freestanding anode for MFCs. The 3D GA/Pt–based anode has a continuous 3D macroporous structure that is favorable for microorganism immobilization and efficient electrolyte transport. Moreover, GA scaffold is homogenously decorated with Pt NPs to further enhance extracellular charge transfer between the bacteria and the anode. The MFCs constructed with 3D GA/Pt–based anode generate a remarkable maximum power density of 1460 mW/m2, 5.3 times higher than that based on carbon cloth (273 mW/m2). It deserves to be stressed that 1460 mW/m2 obtained from the GA/Pt anode shows the superior performance among all the reported MFCs inoculated with Shewanella oneidensis MR-1. Moreover, as a demonstration of the real application, the MFC equipped with the freestanding GA/Pt anode has been successfully applied in driving timer for the first time, which opens the avenue toward the real application of the MFCs. PMID:26702430
Weaver, Abigail A; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-07-02
Reports of low-quality pharmaceuticals have been on the rise in the past decade, with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide and also screen for substitute pharmaceuticals, such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers such as chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain 12 lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a "color bar code" which can be analyzed visually by comparison with standard outcomes. Although quantification of the APIs is poor compared with conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API as well as formulations containing APIs that have been "cut" with inactive ingredients.
Weaver, Abigail A.; Reiser, Hannah; Barstis, Toni; Benvenuti, Michael; Ghosh, Debarati; Hunckler, Michael; Joy, Brittney; Koenig, Leah; Raddell, Kellie; Lieberman, Marya
2013-01-01
Reports of low quality pharmaceuticals have been on the rise in the last decade with the greatest prevalence of substandard medicines in developing countries, where lapses in manufacturing quality control or breaches in the supply chain allow substandard medicines to reach the marketplace. Here, we describe inexpensive test cards for fast field screening of pharmaceutical dosage forms containing beta lactam antibiotics or combinations of the four first-line antituberculosis (TB) drugs. The devices detect the active pharmaceutical ingredients (APIs) ampicillin, amoxicillin, rifampicin, isoniazid, ethambutol, and pyrazinamide, and also screen for substitute pharmaceuticals such as acetaminophen and chloroquine that may be found in counterfeit pharmaceuticals. The tests can detect binders and fillers like chalk, talc, and starch not revealed by traditional chromatographic methods. These paper devices contain twelve lanes, separated by hydrophobic barriers, with different reagents deposited in the lanes. The user rubs some of the solid pharmaceutical across the lanes and dips the edge of the paper into water. As water climbs up the lanes by capillary action, it triggers a library of different chemical tests and a timer to indicate when the tests are completed. The reactions in each lane generate colors to form a “color bar code” which can be analyzed visually by comparison to standard outcomes. While quantification of the APIs is poor compared to conventional analytical methods, the sensitivity and selectivity for the analytes is high enough to pick out suspicious formulations containing no API or a substitute API, as well as formulations containing APIs that have been “cut” with inactive ingredients. PMID:23725012
The high accuracy data processing system of laser interferometry signals based on MSP430
NASA Astrophysics Data System (ADS)
Qi, Yong-yue; Lin, Yu-chi; Zhao, Mei-rong
2009-07-01
Generally speaking there are two orthogonal signals used in single-frequency laser interferometer for differentiating direction and electronic subdivision. However there usually exist three errors with the interferential signals: zero offsets error, unequal amplitude error and quadrature phase shift error. These three errors have a serious impact on subdivision precision. Based on Heydemann error compensation algorithm, it is proposed to achieve compensation of the three errors. Due to complicated operation of the Heydemann mode, a improved arithmetic is advanced to decrease the calculating time effectively in accordance with the special characteristic that only one item of data will be changed in each fitting algorithm operation. Then a real-time and dynamic compensatory circuit is designed. Taking microchip MSP430 as the core of hardware system, two input signals with the three errors are turned into digital quantity by the AD7862. After data processing in line with improved arithmetic, two ideal signals without errors are output by the AD7225. At the same time two original signals are turned into relevant square wave and imported to the differentiating direction circuit. The impulse exported from the distinguishing direction circuit is counted by the timer of the microchip. According to the number of the pulse and the soft subdivision the final result is showed by LED. The arithmetic and the circuit are adopted to test the capability of a laser interferometer with 8 times optical path difference and the measuring accuracy of 12-14nm is achieved.
Revenu, Céline; Streichan, Sebastian; Donà, Erika; Lecaudey, Virginie; Hufnagel, Lars; Gilmour, Darren
2014-03-01
The directed migration of cell collectives drives the formation of complex organ systems. A characteristic feature of many migrating collectives is a 'tissue-scale' polarity, whereby 'leader' cells at the edge of the tissue guide trailing 'followers' that become assembled into polarised epithelial tissues en route. Here, we combine quantitative imaging and perturbation approaches to investigate epithelial cell state transitions during collective migration and organogenesis, using the zebrafish lateral line primordium as an in vivo model. A readout of three-dimensional cell polarity, based on centrosomal-nucleus axes, allows the transition from migrating leaders to assembled followers to be quantitatively resolved for the first time in vivo. Using live reporters and a novel fluorescent protein timer approach, we investigate changes in cell-cell adhesion underlying this transition by monitoring cadherin receptor localisation and stability. This reveals that while cadherin 2 is expressed across the entire tissue, functional apical junctions are first assembled in the transition zone and become progressively more stable across the leader-follower axis of the tissue. Perturbation experiments demonstrate that the formation of these apical adherens junctions requires dynamic microtubules. However, once stabilised, adherens junction maintenance is microtubule independent. Combined, these data identify a mechanism for regulating leader-to-follower transitions within migrating collectives, based on the relocation and stabilisation of cadherins, and reveal a key role for dynamic microtubules in this process.
Informal learning in postgraduate medical education: from cognitivism to 'culturism'.
Swanwick, Tim
2005-08-01
Work-based learning occupies a central role in the training and ongoing development of the medical workforce. With this arises the need to understand the processes involved, particularly those relating to informal learning. Approaches to informal learning in postgraduate medical education have tended to consider the mind as an independent processor of information. In this paper, such cognitive approaches are critiqued and an alternative socio-cultural view on informal learning described. Recent and imminent changes in postgraduate medical education are identified, namely the reduction in patient experience, the fragmentation of teaching, and the development of competency frameworks and structured curricula. It is argued that although the latter may be useful in the construction of formal learning programmes, they will do little to enhance the progression of the individual from newcomer to old-timer or the cultural assimilation of the learner into a profession. Strategies for enhancing informal learning in the workplace are recommended in which increased attention is paid to the development of the medical apprentice within a community of social practice. These include the establishment of strong goals, the use of improvised learning practices, attention to levels of individual engagement and workplace affordances, immersion in professional discourse and behaviours, support in relation to the development of a professional identity and the provision of opportunities to transform social practice.
Self-reported occupational health problems among Libyan dentists.
Arheiam, Arheiam; Ingafou, Mohamed
2015-01-01
To investigate the prevalence of the most common occupation-related health problems as well as factors associated with their incidence among dental practitioners. A cross-sectional, questionnaire-based survey of Libyan dental practitioners. Participants provided information regarding their experience of occupationally related problems they encountered over the past 12 months which included inquiries about musculoskeletal pain, percutaneous injuries, allergy, eye and sight problems, and hearing problems. Musculoskeletal problems were the most frequently reported (48.2%), followed by percutaneous injuries (35%), eye problems (22%), allergy (11%) and hearing problems (7.6%). Musculoskeletal problems were significantly higher among dentists who work in private sector, full timer as well as those who prefer to work in a sitting position (p=0.021, 0.027 and 0.008, respectively). Practitioners with less than 5 years in service reported significantly higher percentage of percutaneous injuries (p=0.027) than their senior counterparts, whereas practitioners who spent more than 10 years in service were more likely to suffer from visual disturbances (p=0.033). The findings of this study indicate that musculoskeletal problems and percutaneous injuries are the most commonly reported occupational health problems among dentists, whereas allergic reactions and hearing problems are the least reported ones. Dentists should use alternate working positions to minimise musculoskeletal problems and adopt more effective strategies to prevent percutaneous injuries particularly among novices.
The research of laser marking control technology
NASA Astrophysics Data System (ADS)
Zhang, Qiue; Zhang, Rong
2009-08-01
In the area of Laser marking, the general control method is insert control card to computer's mother board, it can not support hot swap, it is difficult to assemble or it. Moreover, the one marking system must to equip one computer. In the system marking, the computer can not to do the other things except to transmit marking digital information. Otherwise it can affect marking precision. Based on traditional control methods existed some problems, introduced marking graphic editing and digital processing by the computer finish, high-speed digital signal processor (DSP) control marking the whole process. The laser marking controller is mainly contain DSP2812, digital memorizer, DAC (digital analog converting) transform unit circuit, USB interface control circuit, man-machine interface circuit, and other logic control circuit. Download the marking information which is processed by computer to U disk, DSP read the information by USB interface on time, then processing it, adopt the DSP inter timer control the marking time sequence, output the scanner control signal by D/A parts. Apply the technology can realize marking offline, thereby reduce the product cost, increase the product efficiency. The system have good effect in actual unit markings, the marking speed is more quickly than PCI control card to 20 percent. It has application value in practicality.
Migratory resonances and Wigner timers in the photoionization of fullerene class of molecules
NASA Astrophysics Data System (ADS)
Chakraborty, Himadri
2017-04-01
Empty fullerenes and atom-encaging endofullerenes are quintessential symmetric molecules exhibiting near stability in the room temperature. This property endows them with the quality to be tested for spectroscopic information otherwise inaccessible with regular atoms and molecules. Probing the response of fullerenes and endofullerenes to electromagnetic radiations is one classic way to accomplish this. Conventional spectroscopy of determining the photoelectron count and kinetic energy, as the frequency of the incoming photons varies, predicts varieties of resonances for such molecules. These resonances fundamentally originate from either the correlated electronic motions leading to plasmons or from the molecule's structural symmetry inducing diffractions or even from the mixing of both these effects in tandem. A particularly exotic class of these resonances, which will be emphasized in the talk, includes photoexcitation at one site of the molecule but its subsequent decay at a different location, as well as a coherent admixture of this mechanism with localized Auger processes. The other part of the talk will be devoted to connect to a more contemporary form of spectroscopy by evaluating the time-of-flight of the photoelectron, starting from its production at the molecule to the detector. This utilizes a Wigner clock based on the knowledge of energy-dependent photoelectron quantum phase. It will be shown that the information that can be obtained from the knowledge of this time is often consistent with the underlying electron correlative dynamics, both at the energy region of the giant plasmon resonance and at the generic Cooper-type minima (or anti-resonances). A selection of the results will be presented which are computed by the density functional approximation. The ground state of the molecule is described in a local density approximation (LDA) framework with accurate exchange correlation potential. And a linear-response variant of LDA (TDLDA) is utilized to describe the interaction with the photon. Future research questions will be posed. Besides two postdocs, a PhD student, and the external collaborators, the program involved a large number of undergraduate students. The research is being funded by the US National Science Foundation.
Hart, George W.; Kern, Jr., Edward C.
1987-06-09
An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer.
Note: Low phase noise programmable phase-locked loop with high temperature stability.
Michálek, Vojtěch; Procházka, Ivan
2017-03-01
The design and construction of low jitter programmable phase-locked loop with low temperature coefficient of phase are presented. It has been designed for demanding high precision timing applications, especially as a clock source for event timer with subpicosecond precision. The phase-locked loop itself has a jitter of few hundreds of femtoseconds. It produces square wave with programmable output frequency from 100 MHz to 500 MHz and programmable amplitude of 0.25 V to 1.2 V peak-to-peak, which is locked to 5 MHz or 10 MHz reference frequency common for disciplined oscillators and highly stable clocks such as hydrogen maser. Moreover, it comprises an on-board temperature compensated crystal oscillator for stand-alone usage. The device provides temperature coefficient of the phase lock of 0.9 ps/K near room temperature.
NASA Astrophysics Data System (ADS)
Bucher, François-Xavier; Cao, Frédéric; Viard, Clément; Guichard, Frédéric
2014-03-01
We present in this paper a novel capacitive device that stimulates the touchscreen interface of a smartphone (or of any imaging device equipped with a capacitive touchscreen) and synchronizes triggering with the DxO LED Universal Timer to measure shooting time lag and shutter lag according to ISO 15781:2013. The device and protocol extend the time lag measurement beyond the standard by including negative shutter lag, a phenomenon that is more and more commonly found in smartphones. The device is computer-controlled, and this feature, combined with measurement algorithms, makes it possible to automatize a large series of captures so as to provide more refined statistical analyses when, for example, the shutter lag of "zero shutter lag" devices is limited by the frame time as our measurements confirm.
GEMINI-TITAN (GT)-XI - MISC. EXPERIMENTS - MSC
1966-03-22
S66-05515 (2 June 1966) --- Gemini-11 Experiment S-9 Nuclear Emulsion. This experiment will be used to study the cosmic radiation incident on Earth's atmosphere, to obtain detailed chemical composition of the heavy primary nuclei and to search for rare particles. Equipment is a rectangular package eight and a half by six by three inches weighing 15 pounds and including the nuclear emulsion film stack, motor to advance the emulsion and a timer to regulate the motor. The package is mounted atop the spacecraft retro adapter section prior to launch, is activated at insertion, and is retrieved by the EVA pilot. The experiment is conducted with the spacecraft in plus or minus 15 degrees of Earth's average magnetic field vector. Sponsors are NASA's Office of Space Science and Applications and the U.S. Naval Research Laboratories. Photo credit: NASA
Hart, G.W.; Kern, E.C. Jr.
1987-06-09
An apparatus and method is provided for monitoring a plurality of analog ac circuits by sampling the voltage and current waveform in each circuit at predetermined intervals, converting the analog current and voltage samples to digital format, storing the digitized current and voltage samples and using the stored digitized current and voltage samples to calculate a variety of electrical parameters; some of which are derived from the stored samples. The non-derived quantities are repeatedly calculated and stored over many separate cycles then averaged. The derived quantities are then calculated at the end of an averaging period. This produces a more accurate reading, especially when averaging over a period in which the power varies over a wide dynamic range. Frequency is measured by timing three cycles of the voltage waveform using the upward zero crossover point as a starting point for a digital timer. 24 figs.
xLuna - D emonstrator on ESA Mars Rover
NASA Astrophysics Data System (ADS)
Braga, P.; Henriques, L.; Carvalho, B.; Chevalley, P.; Zulianello, M.
2008-08-01
There is a significant gap between the services offered by existing space qualified Real-Time Operating Systems (RTOS) and those required by the most demanding future space applications. New requirements for autonomy, terrain mapping and navigation, Simultaneous Location and Mapping (SLAM), improvement of the throughput of science tasks, all demand high level services such as file systems or POSIX compliant interfaces. xLuna is an operating system that aims fulfilling these new requirements. Besides providing the typical services that of an RTOS (tasks and interrupts management, timers, message queues, etc), it also includes most of the features available in modern general-purpose operating systems, such as Linux. This paper describes a case study that proposes to demonstrate the usage of xLuna on board a rover currently in use for the development of algorithms in preparation of a mission to Mars.
Performance Analysis of GYRO: A Tool Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Worley, P.; Roth, P.; Candy, J.
2005-06-26
The performance of the Eulerian gyrokinetic-Maxwell solver code GYRO is analyzed on five high performance computing systems. First, a manual approach is taken, using custom scripts to analyze the output of embedded wall clock timers, floating point operation counts collected using hardware performance counters, and traces of user and communication events collected using the profiling interface to Message Passing Interface (MPI) libraries. Parts of the analysis are then repeated or extended using a number of sophisticated performance analysis tools: IPM, KOJAK, SvPablo, TAU, and the PMaC modeling tool suite. The paper briefly discusses what has been discovered via this manualmore » analysis process, what performance analyses are inconvenient or infeasible to attempt manually, and to what extent the tools show promise in accelerating or significantly extending the manual performance analyses.« less
NASA Technical Reports Server (NTRS)
Lala, J. H.; Smith, T. B., III
1983-01-01
The software developed for the Fault-Tolerant Multiprocessor (FTMP) is described. The FTMP executive is a timer-interrupt driven dispatcher that schedules iterative tasks which run at 3.125, 12.5, and 25 Hz. Major tasks which run under the executive include system configuration control, flight control, and display. The flight control task includes autopilot and autoland functions for a jet transport aircraft. System Displays include status displays of all hardware elements (processors, memories, I/O ports, buses), failure log displays showing transient and hard faults, and an autopilot display. All software is in a higher order language (AED, an ALGOL derivative). The executive is a fully distributed general purpose executive which automatically balances the load among available processor triads. Provisions for graceful performance degradation under processing overload are an integral part of the scheduling algorithms.
Radiation hardened microprocessor for small payloads
NASA Technical Reports Server (NTRS)
Shah, Ravi
1993-01-01
The RH-3000 program is developing a rad-hard space qualified 32-bit MIPS R-3000 RISC processor under the Naval Research Lab sponsorship. In addition, under IR&D Harris is developing RHC-3000 for embedded control applications where low cost and radiation tolerance are primary concerns. The development program leverages heavily from commercial development of the MIPS R-3000. The commercial R-3000 has a large installed user base and several foundry partners are currently producing a wide variety of R-3000 derivative products. One of the MIPS derivative products, the LR33000 from LSI Logic, was used as the basis for the design of the RH-3000 chipset. The RH-3000 chipset consists of three core chips and two support chips. The core chips include the CPU, which is the R-3000 integer unit and the FPA/MD chip pair, which performs the R-3010 floating point functions. The two support whips contain all the support functions required for fault tolerance support, real-time support, memory management, timers, and other functions. The Harris development effort had first passed silicon success in June, 1992 with the first rad-hard 32-bit RH-3000 CPU chip. The CPU device is 30 kgates, has a 508 mil by 503 mil die size and is fabricated at Harris Semiconductor on the rad-hard CMOS Silicon on Sapphire (SOS) process. The CPU device successfully passed tesing against 600,000 test vectors derived directly on the LSI/MIPS test suite and has been operational as a single board computer running C code for the past year. In addition, the RH-3000 program has developed the methodology for converting commercially developed designs utilizing logic synthesis techniques based on a combination of VHDK and schematic data bases.
Vegetation of Southwestern watersheds in the nineteenth century
Leopold, Luna Bergere
1951-01-01
The recollections of many old-timers who tell of grass “stirrup high” have given rise to the idea that vegetation in the Southwest was uniformly better in the middle of the last century than it is at present. The change is usually attributed to overgrazing, which timed if it did not cause extensive gullying of the alluvial valleys,I lowering the water table and decreasing the availability of water for plant use. This idea of an originally verdant vegetation, deteriorated as a result of man’s activities, has led to overoptimism concerning the possible results of reduced grazing. Obviously, any decrease in grazing pressure is a step in the right direction, but it is no exaggeration to say that recovery fo vegetation density on depleted ranges, even after protection for years, has been spotty and, in many places, disappointing. We may have allowed ourselves to be deluded by hopes of ‘restoring’ over large areas a level of vegetation density that was originally attained only in selected localities.This conclusion is supported by the published diaries and field notes of members of early American exploring parties. They show that in certain places, particularly in south-central Arizona where grass is now meager, the alluvial valleys formerly supported large expanses of grassland. However, there were also many areas, even alluvial valleys, where grass was so poor that forage for a string of horses could hardly be obtained. Other areas, such as the Rio Puerco Valley, supported good grass in some places but only scattered shrubs, furnishing poor forage, in others, though until well past the middle of the nineteenth century extensive grazing had been prevented by frequent raids of hostile Indians.
Bagonza, James; Rutebemberwa, Elizeus; Eckmanns, Tim; Ekirapa-Kiracho, Elizabeth
2015-11-25
The integrated Community Case Management (iCCM) of childhood illnesses strategy has been adopted world over to reduce child related ill health and mortality. Community Health workers (CHWs) who implement this strategy need a regular supply of drugs to effectively treat children under 5 years with malaria, pneumonia and diarrhea. In this paper, we report the prevalence and factors influencing availability of medicines for managing malaria, pneumonia and diarrhea in communities in central Uganda. A cross sectional study was conducted among 303 CHWs in Wakiso district in central Uganda. Eligible CHWs from two randomly selected Health Sub Districts (HSDs) were interviewed. Questionnaires, check lists, record reviews were used to collect information on CHW background characteristics, CHW's prescription behaviors, health system support factors and availability of iCCM drugs. Multivariable logistic regression analysis was done to assess factors associated with availability of iCCM drugs. Out of 300 CHWs, 239 (79.9%) were females and mean age was 42.1 (standard deviation =11.1 years). The prevalence of iCCM drug availability was 8.3% and 33 respondents (11%) had no drugs at all. Factors associated with iCCM drug availability were; being supervised within the last month (adjusted OR = 3.70, 95% CI 1.22-11.24), appropriate drug prescriptions (adjusted OR = 3.71, 95% CI 1.38-9.96), regular submission of drug reports (adjusted OR = 4.02, 95% CI 1.62-10.10) and having a respiratory timer as a diagnostic tool (adjusted OR =3.11, 95% CI 1.08-9.00). The low medicine stocks for the community management of childhood illnesses calls for strengthening of CHW supervision, medicine prescription and reporting, and increasing availability of functional diagnostic tools.
Metabolic regulation of oocyte cell death through the CaMKII-mediated phosphorylation of caspase-2.
Nutt, Leta K; Margolis, Seth S; Jensen, Mette; Herman, Catherine E; Dunphy, William G; Rathmell, Jeffrey C; Kornbluth, Sally
2005-10-07
Vertebrate female reproduction is limited by the oocyte stockpiles acquired during embryonic development. These are gradually depleted over the organism's lifetime through the process of apoptosis. The timer that triggers this cell death is yet to be identified. We used the Xenopus egg/oocyte system to examine the hypothesis that nutrient stores can regulate oocyte viability. We show that pentose-phosphate-pathway generation of NADPH is critical for oocyte survival and that the target of this regulation is caspase-2, previously shown to be required for oocyte death in mice. Pentose-phosphate-pathway-mediated inhibition of cell death was due to the inhibitory phosphorylation of caspase-2 by calcium/calmodulin-dependent protein kinase II (CaMKII). These data suggest that exhaustion of oocyte nutrients, resulting in an inability to generate NADPH, may contribute to ooctye apoptosis. These data also provide unexpected links between oocyte metabolism, CaMKII, and caspase-2.
Solid state control system for oil well bailer pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Senghaas, K. A.; Senghaas, P.
1985-05-14
A solid state switching controller for use with various types of oil well bailer pumps. Individually programmable steps with lockouts provide multiple mutual exclusivity between various circuit operations. A trickle charge battery system powers the control circuits. A tank overflow float protects against oil spillage. An automatic production rate adjustment circuit is provided which increases cycle time in proportion to the rate of production. The circuit includes a low power voltage detector for disabling the control circuits until the line voltage is acceptable. A three-phase power and control system with an isolation transformer for the controls avoids unreliable ground connections.more » The timers include a dividing circuit with an RC circuit. All power actuated apparatus are actuated by triac switches which are controlled by an opto driver. The bailer brake is pulse actuated for allowing the bailer to sink into crude oil without excess cable looseness.« less
Development Module (Lab Report) As a Media of Learning in Vocational Education Viewed by Gender
NASA Astrophysics Data System (ADS)
Muslim, Supari; Suprianto, Bambang; Putra Gitama, Nahindi
2018-04-01
Module as a media of learning and training, which especially the students studying in institutions offering education at undergraduate and associate levels can employ as a PLC (Programmable Logic Controller) controlled simulator of the logic gate, timer and counter. During industrial manufacturing processes, has been actualized through this work, for the purpose of training qualified technical personnel needed by companies, who are specialized in control and electro mechanics. It was found that, students are very happy learning to use the module so with very significant contributes to a large extent to the training process in favor of faculty members, who are to train personnel for the sector, and in favor of students, who should be able to acquire proper education. Working on the training tool allows students to acquire knowledge and practical skills and then make use of those skills for troubleshooting and control of machinery.
Fast time-correlated multi-element photon detector and method
Hayden, Carl C.; Chandler, David W.; Luong, A. Khai
2007-12-18
Photons emitted from a sample responsive to being excited by laser pulses are directed through a prism onto a photomultiplier tube having several spaced-apart anodes. The prism alters the path of each photon as a function of its wavelength so that the wavelength determines the anode to which the photon is directed. Taps of first and second delay lines that are coupled to respective alternating anodes. When an anode receives the photon, it generates a pulse that propagates through the delay line in opposite directions from its associated tap. A timer determines first and second times from the laser pulse to the pulse reaching the first and second ends of the delay line. The difference between the first and second times corresponds to the wavelength of the emitted photon and the sum of the first and second times corresponds to the emission delay of the emitted photon.
Single-chip pulse programmer for magnetic resonance imaging using a 32-bit microcontroller.
Handa, Shinya; Domalain, Thierry; Kose, Katsumi
2007-08-01
A magnetic resonance imaging (MRI) pulse programmer has been developed using a single-chip microcontroller (ADmicroC7026). The microcontroller includes all the components required for the MRI pulse programmer: a 32-bit RISC CPU core, 62 kbytes of flash memory, 8 kbytes of SRAM, two 32-bit timers, four 12-bit DA converters, and 40 bits of general purpose I/O. An evaluation board for the microcontroller was connected to a host personal computer (PC), an MRI transceiver, and a gradient driver using interface circuitry. Target (embedded) and host PC programs were developed to enable MRI pulse sequence generation by the microcontroller. The pulse programmer achieved a (nominal) time resolution of approximately 100 ns and a minimum time delay between successive events of approximately 9 micros. Imaging experiments using the pulse programmer demonstrated the effectiveness of our approach.
The Simplest Chronoscope V: A Theory of Dual Primary and Secondary Reaction Time Systems.
Montare, Alberto
2016-12-01
Extending work by Montare, visual simple reaction time, choice reaction time, discriminative reaction time, and overall reaction time scores obtained from college students by the simplest chronoscope (a falling meterstick) method were significantly faster as well as significantly less variable than scores of the same individuals from electromechanical reaction timers (machine method). Results supported the existence of dual reaction time systems: an ancient primary reaction time system theoretically activating the V5 parietal area of the dorsal visual stream that evolved to process significantly faster sensory-motor reactions to sudden stimulations arising from environmental objects in motion, and a secondary reaction time system theoretically activating the V4 temporal area of the ventral visual stream that subsequently evolved to process significantly slower sensory-perceptual-motor reactions to sudden stimulations arising from motionless colored objects. © The Author(s) 2016.
STS-93 Flight Day 1 Highlights and Crew Activities
NASA Technical Reports Server (NTRS)
1999-01-01
On this first day of the STS-93 Columbia mission, the flight crew, Commander Eileen Collins, Pilot Jeff Ashby and Mission Specialists Cady Coleman, Steve Hawley and Michael Tognini deployed the Chandra X-Ray Observatory into space. This was done after a full night of work and preparation. Chandra will study the invisible, and often violent mysteries of x-ray astronomy. Commander Collins maneuvered Columbia to a safe distance away from the telescope as an internal timer counted down to the first of a two-phase ignition of the Inertial Upper Stage. After switching to internal battery power until its solar rays are deployed, the telescope reaches an oval orbit one-third the distance to the Moon to conduct its astronomical observations. Since Chandra is safely on its way and the major objective of their mission is successfully completed, the astronauts end their long day and begin an eight hour sleep period.
Development of a large low-cost double-chamber vacuum laminator
NASA Technical Reports Server (NTRS)
Burger, D. R.
1983-01-01
A double-chamber vacuum laminator was required to investigate the processing and control of the fabrication of large terrestrial photovoltaic modules, and economic problems arising therefrom. Major design considerations were low cost, process flexibility and the exploration of novel equipment approaches. Spherical end caps for industrial tanks were used for the vacuum chambers. A stepping programmer and adjustable timers were used for process flexibility. New processing options were obtained by use of vacuum sensors. The upper vacuum chamber was provided with a diaphragm support to reduce diaphragm stress. A counterweight was used for handling ease and safety. Heat was supplied by a large electrical strip heater. Thermal isolation and mechanical support were provided inexpensively by a bed of industrial marbles. Operational testing disclosed the need for a differential vacuum gauge and proportional valve. Reprogramming of the process control system was simple and quick.
Development of strand burner for solid propellant burning rate studies
NASA Astrophysics Data System (ADS)
Aziz, A.; Mamat, R.; Ali, W. K. Wan
2013-12-01
It is well-known that a strand burner is an apparatus that provides burning rate measurements of a solid propellant at an elevated pressure in order to obtain the burning characteristics of a propellant. This paper describes the facilities developed by author that was used in his studies. The burning rate characteristics of solid propellant have be evaluated over five different chamber pressures ranging from 1 atm to 31 atm using a strand burner. The strand burner has a mounting stand that allows the propellant strand to be mounted vertically. The strand was ignited electrically using hot wire, and the burning time was recorded by electronic timer. Wire technique was used to measure the burning rate. Preliminary results from these techniques are presented. This study shows that the strand burner can be used on propellant strands to obtain accurate low pressure burning rate data.
Single-chip pulse programmer for magnetic resonance imaging using a 32-bit microcontroller
NASA Astrophysics Data System (ADS)
Handa, Shinya; Domalain, Thierry; Kose, Katsumi
2007-08-01
A magnetic resonance imaging (MRI) pulse programmer has been developed using a single-chip microcontroller (ADμC7026). The microcontroller includes all the components required for the MRI pulse programmer: a 32-bit RISC CPU core, 62kbytes of flash memory, 8kbytes of SRAM, two 32-bit timers, four 12-bit DA converters, and 40bits of general purpose I/O. An evaluation board for the microcontroller was connected to a host personal computer (PC), an MRI transceiver, and a gradient driver using interface circuitry. Target (embedded) and host PC programs were developed to enable MRI pulse sequence generation by the microcontroller. The pulse programmer achieved a (nominal) time resolution of approximately 100ns and a minimum time delay between successive events of approximately 9μs. Imaging experiments using the pulse programmer demonstrated the effectiveness of our approach.
To catch a comet: Technical overview of CAN DO G-324
NASA Technical Reports Server (NTRS)
Obrien, T. J. (Editor)
1986-01-01
The primary objective of the C. E. Williams Middle School Get Away Special CAN DO is the photographing of Comet Halley. The project will involve middle school students, grades 6 through 8, in the study and interpretation of astronomical photographs and techniques. G-324 is contained in a 5 cubic foot GAS Canister with an opening door and pyrex window for photography. It will be pressurized with one atmosphere of dry nitrogen. Three 35mm still cameras with 250 exposure film backs and different focal length lenses will be fired by a combination of automatic timer and an active comet detector. A lightweight 35mm movie camera will shoot single exposures at about 1/2 minute intervals to give an overlapping skymap of the mission. The fifth camera is a solid state television camera specially constructed for detection of the comet by microprocessor.
Multichannel electrochemical microbial detection unit
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Young, R. N.; Boykin, E. H.
1978-01-01
The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.
Poor ultrafiltration during nighttime dialysis in CAPD patients and its effects on fluid balance.
Pagé, D E; Levine, D Z
1993-01-01
To evaluate fluid retention during the long nighttime peritoneal dwell in continuous ambulatory peritoneal dialysis (CAPD) patients, we measured remaining volumes in 70 patients. In only 50% of these patients were more than 2 L of fluid recovered; in 30% between 1.5 and 2 L were recovered; and in 17% of patients we retrieved less than 1.5 L of peritoneal fluid. In 3 of these patients, who were edematous and had marked pitting edema, we shortened the nighttime dwell by having the patients awaken after 4 hours and drain the dwell. This resulted in 3-5 kg of weight loss in each patient, when compared with each patient's previous use of long nighttime dwells. Finally, we propose in this report two automated methods whereby the period of nighttime dialysis can be controlled, while patients sleep, using a system of timer clamps.
Process for Administering Distributed Academic Competitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feibush, Eliot
2010-02-04
Currently, academic-type competitions are scored using a combination of timer clocks, entries on paper, and individual computers to consolidate individual entries. Such a system is unwieldy, time-consuming, and depends on the individual computer skills that might be present amount the competition administrators. The new Academic Competition Software combines digital clocks, along with a scoring system that permits different point values for different types of questions. Bonus or Âtoss-up questions can be monitored during the competition, using a subtimer system. All data is consolidated on the fly and the system can be operated by a single person. Results from different sitesmore » (rooms) can be added in as well. As such, the software is extremely flexible. It is anticipated that this new software will be useful forScience or Science Olympiad type competitions held in many high schools and colleges, as well as for preparation and training for such competitions.« less
LBNP as useful tool for pilot candidates selection to the Polish Air Force: a preliminary study.
Romuald, M; Mariusz, Z; Artur, D; Krzysztof, R
2001-07-01
Candidates to the Polish Air Force are to fulfill strict medical conditions. Every candidate, wanting to become a fighter pilot or not, has to pass a rigorous centrifuge examination. This is a costly and especially stressful process for the candidates, as first-timers. This article explores possibility for different approach to candidates fitness to fly assessment. 14 candidates (21-22 yrs old) were subjected to a regular GOR centrifuge profile (0.1 G/s; up to +7.0 Gz; unprotected) and to lower body negative pressure (LBNP) examination (2 min. rest period followed by 3 min. at -40 mm Hg; supine position). Both, centrifuge and LBNP examinations were carried out the same day, with about 1 hour gap between them. ECG and impedance cardiography (ICG) were being recorded during both tests. The following parameters were calculated: HR and QZ (time between ventricular depolarization [beginning of the Q wave in ECG] and local maximum of the first derivative [dZ/dt] in ICG). QZ was considered to be an effective measure of dynamic heart function. +Gz tolerance for the group was +5.94 +/- 0.98 Gz. Correlation between +Gz tolerance and QZ values during LBNP test (-40 mm Hg) for all subjects was equal to r=0.6. Correlation between sets of parameters (canonical analysis) for LBNP and centrifuge was equal to r=0.78. Both results were statistically insignificant (p<0.09). Baseline HR values were 121 +/- 19 bpm and 75 +/- 12 bpm, and maximal HR values were 172 +/- 21 bpm and 81 +/- 13 bpm, respectively for centrifuge and LBNP. For both, baseline and maximal HR during LBNP and G exposure canonical correlation was equal to r=0.72. The results were statistically not significant, however. Centrifuge examination is much more stressful than LBNP test. This could have implication on the objective results of centrifuge test. The results may suggest that LBNP test could be a used in pilot candidates selection, especially those presenting high baseline HR values.
NASA Technical Reports Server (NTRS)
Nelson, R. A.; Alley, C. O.; Rayner, J. D.; Shih, Y. H.; Steggerda, C. A.; Wang, B. C.; Agnew, B. W.
1993-01-01
An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.
How do repeat suicide attempters differ from first timers? An exploratory record based analysis
Menon, Vikas; Kattimani, Shivanand; Sarkar, Siddharth; Mathan, Kaliaperumal
2016-01-01
Background: Evidence indicates that repeat suicide attempters, as a group, may differ from 1st time attempters. The identification of repeat attempters is a powerful but underutilized clinical variable. Aims: In this research, we aimed to compare individuals with lifetime histories of multiple attempts with 1st time attempters to identify factors predictive of repeat attempts. Setting and Design: This was a retrospective record based study carried out at a teaching cum Tertiary Care Hospital in South India. Methods: Relevant data was extracted from the clinical records of 1st time attempters (n = 362) and repeat attempters (n = 61) presenting to a single Tertiary Care Center over a 4½ year period. They were compared on various sociodemographic and clinical parameters. The clinical measures included Presumptive Stressful Life Events Scale, Beck Hopelessness Scale, Coping Strategies Inventory – Short Form, and the Global Assessment of Functioning Scale. Statistical Analysis Used: First time attempters and repeaters were compared using appropriate inferential statistics. Logistic regression was used to identify independent predictors of repeat attempts. Results: The two groups did not significantly differ on sociodemographic characteristics. Repeat attempters were more likely to have given prior hints about their act (χ2 = 4.500, P = 0.034). In the final regression model, beck hopelessness score emerged as a significant predictor of repeat suicide attempts (odds ratio = 1.064, P = 0.020). Conclusion: Among suicide attempters presenting to the hospital, the presence of hopelessness is a predictor of repeat suicide attempts, independent of clinical depression. This highlights the importance of considering hopelessness in the assessment of suicidality with a view to minimize the risk of future attempts. PMID:26933353
Gilinsky, A; Swanson, V; Merrett, M; Power, K; Marley, L
2012-03-01
Investigate the effect of a theory-based intervention on oral-health knowledge, attitudes and behaviours of early years staff (EYS), parents and nursery children. Qualitative research with staff and parents from eight nurseries through interviews/focus groups. An intervention was developed and piloted using pre-posttest design. Nurseries in deprived communities in Dundee, Scotland. 111 children aged 3-5 years attending nursery, including 79 parents and 8 nursery staff. Staff session targeted outcome expectancies, subjective norms and self-efficacy for tooth-brushing in nursery using information provision, modelling and goal-setting, followed by a three-week intervention. Parent-child dyads received a leaflet with instructions for goal-setting, planning and monitoring home brushing. Tooth-brushing self-monitoring materials (e.g. two-minute timer, diaries) were used and certificates provided in the nursery as rewards. EYS knowledge, attitudes and behaviours were assessed before and after the intervention using self-report questionnaires. Parents completed interviews assessing beliefs about tooth-brushing and their children's tooth-brushing behaviour at baseline and post-intervention follow-up. Significant improvements in staff knowledge, but not attitudes, self-efficacy, or nursery tooth-brushing were reported. Parent-child dyads completing the intervention were not more likely to report their child carried out twice-daily tooth-brushing at home. The intervention did not improve parents' intentions to brush their child's teeth twice a day or beliefs about the ease of twice-daily tooth-brushing. Only past behaviour significantly predicted posttest brushing. Parents who found brushing easier at baseline were more likely to complete the intervention. Recommendations are made regarding implementing psychological theory and methods into oral-health interventions.
A SIEPON based transmitter sleep mode energy-efficient mechanism in EPON
NASA Astrophysics Data System (ADS)
Nikoukar, AliAkbar; Hwang, I.-Shyan; Wang, Chien-Jung; Ab-Rahman, Mohammad Syuhaimi; Liem, Andrew Tanny
2015-06-01
The main energy consumption in computer networks is the access networks. The passive optical network (PON) has the least energy consumption among access network technologies. In addition, the time division multiplexing (TDM) Ethernet PON (EPON) is one of the best candidates to improve energy consumption by time utilization. The optical network unit (ONU) can utilize the time and save the energy in the EPON by turning off its transmitter/receiver when there is no upstream/downstream traffic. The ITU-T and IEEE organizations are published standards for energy-saving in the TDM-PON. Although their standards provide the framework to accomplish the energy-saving, the algorithms/criteria to generate events to accommodate various operational policies, time to wake up, parameter values for timers are out of scope of the standards. Many studies have proposed schemes for energy-saving in TDM-PON to achieve maximum energy saving. Even so, these schemes increase the mean packet delay and consequently, reduce the quality of service (QoS). In this paper, first we take a look to the state of the art for PON energy-saving. Additionally, a mechanism based on SIEPON standard in EPON with new components in the ONUs and optical line terminal (OLT) is proposed to save the transmitter energy and guarantee QoS. The proposed mechanism follows the SIEPON standard, considers the QoS first, and then saves the energy as far as possible. The ONU sleep controller unit (OSC) and green dynamic bandwidth allocation (GDBA) are used to calculate the ONU transmitter sleep (Tx) duration and grant the proper time to the ONUs. Simulation results show that the proposed energy-saving mechanism not only promises the QoS performance in terms of mean packet delay, packet loss, throughput, and jitter, but also saves energy in different maximum cycle times.
An Arduino-Controlled Photogate
NASA Astrophysics Data System (ADS)
Galeriu, Calin
2013-03-01
It is hard to imagine teaching physics without doing experimental measurements of position as a function of time. These measurements, needed for the determination of velocity and acceleration, are most easily performed with the help of photogates.1,2 Unfortunately, commercial photogates are rather expensive. Many require the purchase of an additional matching timer or other electronic device. Sometimes special software is also needed. The total bill can easily become prohibitive. For this reason physics teachers have shown considerable interest for cheaper, in-house designed and manufactured photogates.3-6 The photogate systems described in the literature have their limitations. Some rely on a digital stopwatch and therefore cannot measure time with a precision higher than 0.01 seconds. Some use photoresistors that have a slower response than phototransistors. Some are based on the computer microphone port and therefore cannot handle more than two photogates (two audio channels) at the same time. Extracting the time information from an audio file can also be a challenge for some students. We describe here a photogate system that matches the performance of a commercial one but at a fraction of the cost. The key to this success is the use of an Arduino microcontroller for data collection. The Arduino platform, initially developed for electronics and robotics educational projects, has recently been incorporated in physics labs.7 The Arduino microcontroller, because of its low cost and because it provides a broad exposure to electronics and computer programming, is an ideal tool for integrated STEM projects.
Wide-Range Temperature Sensors with High-Level Pulse Train Output
NASA Technical Reports Server (NTRS)
Hammoud, Ahmad; Patterson, Richard L.
2009-01-01
Two types of temperature sensors have been developed for wide-range temperature applications. The two sensors measure temperature in the range of -190 to +200 C and utilize a thin-film platinum RTD (resistance temperature detector) as the temperature-sensing element. Other parts used in the fabrication of these sensors include NPO (negative-positive- zero) type ceramic capacitors for timing, thermally-stable film or wirewound resistors, and high-temperature circuit boards and solder. The first type of temperature sensor is a relaxation oscillator circuit using an SOI (silicon-on-insulator) operational amplifier as a comparator. The output is a pulse train with a period that is roughly proportional to the temperature being measured. The voltage level of the pulse train is high-level, for example 10 V. The high-level output makes the sensor less sensitive to noise or electromagnetic interference. The output can be read by a frequency or period meter and then converted into a temperature reading. The second type of temperature sensor is made up of various types of multivibrator circuits using an SOI type 555 timer and the passive components mentioned above. Three configurations have been developed that were based on the technique of charging and discharging a capacitor through a resistive element to create a train of pulses governed by the capacitor-resistor time constant. Both types of sensors, which operated successfully over the wide temperature range, have potential use in extreme temperature environments including jet engines and space exploration missions.
Cinquin, Olivier
2009-01-01
Stem cells are expected to play a key role in the development and maintenance of organisms, and hold great therapeutic promises. However, a number of questions must be answered to achieve an understanding of stem cells and put them to use. Here I review some of these questions, and how they relate to the model system provided by the Caenorhabditis elegans germ line, which is exceptional in its thorough genetic characterization and experimental accessibility under in vivo conditions. A fundamental question is how to define a stem cell; different definitions can be adopted that capture different features of interest. In the C. elegans germ line, stem cells can be defined by cell lineage or by cell commitment ('commitment' must itself be carefully defined). These definitions are associated with two other important questions about stem cells: their functions (which must be addressed following a systems approach, based on an evolutionary perspective) and their regulation. I review possible functions and their evolutionary groundings, including genome maintenance and powerful regulation of cell proliferation and differentiation, and possible regulatory mechanisms, including asymmetrical division and control of transit amplification by a developmental timer. I draw parallels between Drosophila and C. elegans germline stem cells; such parallels raise intriguing questions about Drosophila stem cells. I conclude by showing that the C. elegans germ line bears similarities with a number of other stem cell systems, which underscores its relevance to the understanding of stem cells.
Flexible Peripheral Component Interconnect Input/Output Card
NASA Technical Reports Server (NTRS)
Bigelow, Kirk K.; Jerry, Albert L.; Baricio, Alisha G.; Cummings, Jon K.
2010-01-01
The Flexible Peripheral Component Interconnect (PCI) Input/Output (I/O) Card is an innovative circuit board that provides functionality to interface between a variety of devices. It supports user-defined interrupts for interface synchronization, tracks system faults and failures, and includes checksum and parity evaluation of interface data. The card supports up to 16 channels of high-speed, half-duplex, low-voltage digital signaling (LVDS) serial data, and can interface combinations of serial and parallel devices. Placement of a processor within the field programmable gate array (FPGA) controls an embedded application with links to host memory over its PCI bus. The FPGA also provides protocol stacking and quick digital signal processor (DSP) functions to improve host performance. Hardware timers, counters, state machines, and other glue logic support interface communications. The Flexible PCI I/O Card provides an interface for a variety of dissimilar computer systems, featuring direct memory access functionality. The card has the following attributes: 8/16/32-bit, 33-MHz PCI r2.2 compliance, Configurable for universal 3.3V/5V interface slots, PCI interface based on PLX Technology's PCI9056 ASIC, General-use 512K 16 SDRAM memory, General-use 1M 16 Flash memory, FPGA with 3K to 56K logical cells with embedded 27K to 198K bits RAM, I/O interface: 32-channel LVDS differential transceivers configured in eight, 4-bit banks; signaling rates to 200 MHz per channel, Common SCSI-3, 68-pin interface connector.
Protein quality control at the inner nuclear membrane
Khmelinskii, Anton; Blaszczak, Ewa; Pantazopoulou, Marina; Fischer, Bernd; Omnus, Deike J.; Le Dez, Gaëlle; Brossard, Audrey; Gunnarsson, Alexander; Barry, Joseph D.; Meurer, Matthias; Kirrmaier, Daniel; Boone, Charles; Huber, Wolfgang; Rabut, Gwenaël; Ljungdahl, Per O.; Knop, Michael
2015-01-01
The nuclear envelope is a double membrane that separates the nucleus from the cytoplasm. The inner nuclear membrane (INM) functions in essential nuclear processes including chromatin organization and regulation of gene expression1. The outer nuclear membrane is continuous with the endoplasmic reticulum (ER) and is the site of membrane protein synthesis. Protein homeostasis in this compartment is ensured by ER-associated protein degradation (ERAD) pathways that in yeast involve the integral membrane E3 ubiquitin ligases Hrd1 and Doa10 operating with the E2 ubiquitin-conjugating enzymes Ubc6 and Ubc72,3. However, little is known regarding protein quality control at the INM. Here we describe a protein degradation pathway at the INM mediated by the Asi complex consisting of the RING domain proteins Asi1 and Asi34. We report that the As complex functions together with the ubiquitin conjugating enzymes Ubc6andUbc7to degrade soluble and integral membrane proteins. Genetic evidence suggest that the Asi ubiquitin ligase defines a pathway distinct from but complementary to ERAD. Using unbiased screening with a novel genome-wide yeast library based on a tandem fluorescent protein timer (tFT)5, we identify more than 50 substrates of the Asi, Hrd1 and Doa10 E3 ubiquity ligases. We show that the Asi ubiquitin ligase is involved in degradation of mislocalised integral membrane proteins, thus acting to maintain and safeguard the identity of the INM. PMID:25519137
Test Waveform Applications for JPL STRS Operating Environment
NASA Technical Reports Server (NTRS)
Lux, James P.; Peters, Kenneth J.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.; Duncan, Courtney B.
2013-01-01
This software demonstrates use of the JPL Space Telecommunications Radio System (STRS) Operating Environment (OE), tests APIs (application programming interfaces) presented by JPL STRS OE, and allows for basic testing of the underlying hardware platform. This software uses the JPL STRS Operating Environment ["JPL Space Tele com - munications Rad io System Operating Environment,"(NPO-4776) NASA Tech Briefs, commercial edition, Vol. 37, No. 1 (January 2013), p. 47] to interact with the JPL-SDR Software Defined Radio developed for the CoNNeCT (COmmunications, Navigation, and Networking rEconfigurable Testbed) Project as part of the SCaN Testbed installed on the International Space Station (ISS). These are the first applications that are compliant with the new NASA STRS Architecture Standard. Several example waveform applications are provided to demonstrate use of the JPL STRS OE for the JPL-SDR platform used for the CoNNeCT Project. The waveforms provide a simple digitizer and playback capability for the SBand RF slice, and a simple digitizer for the GPS slice [CoNNeCT Global Positioning System RF Module, (NPO-47764) NASA Tech Briefs, commercial edition, Vol. 36, No. 3 (March 2012), p. 36]. These waveforms may be used for hardware test, as well as for on-orbit or laboratory checkout. Additional example waveforms implement SpaceWire and timer modules, which can be used for time transfer and demonstration of communication between the two Xilinx FPGAs in the JPLSDR. The waveforms are also compatible with ground-based use of the JPL STRS OE on radio breadboards and Linux.
Achieving Fair Throughput among TCP Flows in Multi-Hop Wireless Mesh Networks
NASA Astrophysics Data System (ADS)
Hou, Ting-Chao; Hsu, Chih-Wei
Previous research shows that the IEEE 802.11 DCF channel contention mechanism is not capable of providing throughput fairness among nodes in different locations of the wireless mesh network. The node nearest the gateway will always strive for the chance to transmit data, causing fewer transmission opportunities for the nodes farther from the gateway, resulting in starvation. Prior studies modify the DCF mechanism to address the fairness problem. This paper focuses on the fairness study when TCP flows are carried over wireless mesh networks. By not modifying lower layer protocols, the current work identifies TCP parameters that impact throughput fairness and proposes adjusting those parameters to reduce frame collisions and improve throughput fairness. With the aid of mathematical formulation and ns2 simulations, this study finds that frame transmission from each node can be effectively controlled by properly controlling the delayed ACK timer and using a suitable advertised window. The proposed method reduces frame collisions and greatly improves TCP throughput fairness.
ULK3 regulates cytokinetic abscission by phosphorylating ESCRT-III proteins
Caballe, Anna; Wenzel, Dawn M.; Agromayor, Monica; ...
2015-05-26
The endosomal sorting complexes required for transport (ESCRT) machinery mediates the physical separation between daughter cells during cytokinetic abscission. This process is regulated by the abscission checkpoint, a genome protection mechanism that relies on Aurora B and the ESCRT-III subunit CHMP4C to delay abscission in response to chromosome missegregation. In this study, we show that Unc-51-like kinase 3 (ULK3) phosphorylates and binds ESCRT-III subunits via tandem MIT domains, and thereby, delays abscission in response to lagging chromosomes, nuclear pore defects, and tension forces at the midbody. Our structural and biochemical studies reveal an unusually tight interaction between ULK3 and IST1,more » an ESCRT-III subunit required for abscission. We also demonstrate that IST1 phosphorylation by ULK3 is an essential signal required to sustain the abscission checkpoint and that ULK3 and CHMP4C are functionally linked components of the timer that controls abscission in multiple physiological situations.« less
Davies, B R; Leung, A N; Dunne, S M
2013-05-01
Dental schools in the United Kingdom are becoming increasingly reliant on the services of part-time teachers to deliver the clinical educational component of the dental course. Their background is predominantly from general dental practice but the opportunities to progress in the system are limited. The aim of this study was to ascertain the views and perceptions of such teachers at a dental school. An anonymous, non-incentivised online survey was used to obtain both qualitative and quantitative views of the part timers. The department has n = 40 part-time teachers and there was a response rate of 78%. Overall 73% were satisfied with their current teaching position, whereas the remaining 27% of teachers were seeking higher rewards both in terms of recognition and status. This study demonstrated the need for formal teaching skills and training to be made available to part-time clinical teachers. Allied to this is the requirement for a clearly defined and achievable career pathway.
Complementary system for long term measurements of radon exhalation rate from soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mazur, J.; Kozak, K., E-mail: Krzysztof.Kozak@ifj.edu.pl
A special set-up for continuous measurements of radon exhalation rate from soil is presented. It was constructed at Laboratory of Radiometric Expertise, Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN), Krakow, Poland. Radon exhalation rate was determined using the AlphaGUARD PQ2000 PRO (Genitron) radon monitor together with a special accumulation container which was put on the soil surface during the measurement. A special automatic device was built and used to raise and lower back onto the ground the accumulation container. The time of raising and putting down the container was controlled by an electronic timer. This set-up mademore » it possible to perform 4–6 automatic measurements a day. Besides, some additional soil and meteorological parameters were continuously monitored. In this way, the diurnal and seasonal variability of radon exhalation rate from soil can be studied as well as its dependence on soil properties and meteorological conditions.« less
Climate Science Performance, Data and Productivity on Titan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayer, Benjamin W; Worley, Patrick H; Gaddis, Abigail L
2015-01-01
Climate Science models are flagship codes for the largest of high performance computing (HPC) resources, both in visibility, with the newly launched Department of Energy (DOE) Accelerated Climate Model for Energy (ACME) effort, and in terms of significant fractions of system usage. The performance of the DOE ACME model is captured with application level timers and examined through a sizeable run archive. Performance and variability of compute, queue time and ancillary services are examined. As Climate Science advances in the use of HPC resources there has been an increase in the required human and data systems to achieve programs goals.more » A description of current workflow processes (hardware, software, human) and planned automation of the workflow, along with historical and projected data in motion and at rest data usage, are detailed. The combination of these two topics motivates a description of future systems requirements for DOE Climate Modeling efforts, focusing on the growth of data storage and network and disk bandwidth required to handle data at an acceptable rate.« less
ATimer-Actuated, Immunoassay Cassette for Detecting Molecular Markers in Oral Fluids
Liu, Changchun; Qiu, Xianbo; Ongagna, Serge; Chen, Dafeng; Chen, Zongyuan; Abrams, William R.; Malamud, Daniel; Corstjens, Paul L.A.M.; Bau, Haim H.
2009-01-01
An inexpensive, hand-held, point-of-care, disposable, self-contained, immunoassay cassette comprised of air pouches for pumping, a metering chamber, reagents storage chambers, a mixer, and a lateral flow strip was designed, constructed, and tested. The assay was carried out in a consecutive flow format. The detection was facilitated with up-converting, phosphor (UCP) reporter particles. The automated, timely pumping of the various reagents was driven by a spring-loaded timer. The utility of the cassette was demonstrated by detecting antibodies to HIV in saliva samples and further evaluated with a non-contagious, haptenized DNA assay. The cassette has several advantages over dip sticks such as sample preprocessing, integrated storage of reagents, and automated operation that reduces operator errors and training. The cassette and actuator described herein can readily be extended to detect biomarkers of other diseases in body fluids and other fluids at the point of care. The system is particularly suitable for resource poor countries, where funds and trained personnel are in short supply. PMID:19255658
Terminal velocity of a shuttlecock in vertical fall
NASA Astrophysics Data System (ADS)
Peastrel, Mark; Lynch, Rosemary; Armenti, Angelo
1980-07-01
We have performed a straightforward vertical fall experiment for a case where the effects of air resistance are important and directly measurable. Using a commonly available badminton shuttlecock, a tape measure, and a millisecond timer, the times required for the shuttlecock to fall given distances (up to almost ten meters) were accurately measured. The experiment was performed in an open stairwell. The experimental data was compared to the predictions of several models. The best fit was obtained with the model which assumes a resistive force quadratic in the instantaneous speed of the falling object. This model was fitted to the experimental data enabling us to predict the terminal velocity of the shuttlecock (6.80 m/sec). The results indicate that, starting from rest, the vertically falling shuttlecock achieves 99% of its terminal velocity in 1.84 sec, after falling 9.2 m. The relative ease in collecting the data, as well as the excellent agreement with theory, make this an ideal experiment for use in physics courses at a variety of levels.
[Development of an electronic device to organize medications and promote treatment adherence].
Vieira, Liliana Batista; Ramos, Celso de Ávila; Castello, Matheus de Barros; Nascimento, Lorenzo Couto do
2016-04-01
This article describes the development of an electronic prototype to organize medications - the Electronic System for Personal and Controlled Use of Medications (Sistema Eletrônico de Uso Personalizado e Controlado de Medicamentos, SUPERMED). The prototype includes a drawer containing 1 month's supply of medicines, sound and visual medication timers, and a memory card for recording the times when the box was opened/closed (scheduled and unscheduled). This information is later transferred to a computer. Evolutionary prototyping was used to develop SUPERMED with the Arduino platform and C programming. To read alarm and box opening/closing data, software was developed in Java. Once the alarms are programmed (ideally by a health care professional), no additional adjustments are required by the patient. The prototype was tested during 31 days by the developers, with satisfactory functioning. The system seems adequate to organize medications and facilitate adherence to treatment. New studies will be carried out to validate and improve the prototype.
NASA Technical Reports Server (NTRS)
Estes, Joseph C., Jr.; Arca. Jeremy M.; Ko, Michael A.; Oks, Boris
2012-01-01
The Office of the CIO at JPL has developed an iPhone application for the Aquarius/SAC-D mission. The application includes specific information about the science and purpose of the Aquarius satellite and also features daily mission news updates pulled from sources at Goddard Space Flight Center as well as Twitter. The application includes a media and data tab section. The media section displays images from the observatory, viewing construction up to the launch and also includes various videos and recorded diaries from the Aquarius Project Manager. The data tab highlights many of the factors that affect the Earth s ocean and the water cycle. The application leverages the iPhone s accelerometer to move the Aquarius Satellite over the Earth, revealing these factors. Lastly, this application features a countdown timer to the satellite s launch, which is currently counting the days since launch. This application was highly successful in promoting the Aquarius Mission and educating the public about how ocean salinity is paramount to understanding the Earth.
Internet Teleoperation of a Robot with Streaming Buffer System under Varying Time Delays
NASA Astrophysics Data System (ADS)
Park, Jahng-Hyon; Shin, Wanjae
It is known that existence of irregular transmission time delay is a major bottleneck for application of advanced robot control schemes to internet telerobotic systems. In the internet teleoperation system, the irregular transmission time delay causes a critical problem, which includes instability and inaccuracy. This paper suggests a practical internet teleoperation system with streaming buffer system, which consists of a buffer, a buffer manager, and a control timer. The proposed system converts the irregular transmission time delay to a constant. So, the system effectively transmits the control input to a remote site to operate a robot stably and accurately. This feature enables short control input intervals. That means the entire system has a large control bandwidth. The validity of the proposed method is demonstrated by experiments of teleoperation from USC (University of Southern California in U. S.A.) to HYU (Hanyang Univ. in Korea) through the Internet. The proposed method is also demonstrated by experiments of teleoperation through the wireless internet.
O'Callaghan, Patrick M; Allen, Keith D; Powell, Shawn; Salama, Fouad
2006-01-01
We evaluated the effectiveness of a dentist-implemented behavioral intervention in which brief escape from dental treatment was provided on a regular basis, independent of the child's behavior. Within a multiple baseline design across subjects, 5 children, ages 4 to 7 years, were provided with temporary escape from dental treatment on a fixed-time schedule. The intervals were signaled by an electronic timer worn by the dentist. Clinically significant reductions were observed in physically disruptive behavior across all 5 children with the introduction of noncontingent escape, and verbally disruptive behavior was markedly reduced in 4 of the 5 children. In addition, the dental staff's use of physical restraint was reduced to near zero across all 5 children. The research extends the literature in both clinical dentistry and in applied behavior analysis by demonstrating that a dentist can easily and effectively implement noncontingent reinforcement to produce clinically significant and socially important changes in children's health behavior. PMID:16813038
Eyler, E E
2011-01-01
A 16-bit digital event sequencer with 50 ns resolution and 50 ns trigger jitter is implemented by using an internal 32-bit timer on a dsPIC30F4013 microcontroller, controlled by an easily modified program written in standard C. It can accommodate hundreds of output events, and adjacent events can be spaced as closely as 1.5 μs. The microcontroller has robust 5 V inputs and outputs, allowing a direct interface to common laboratory equipment and other electronics. A USB computer interface and a pair of analog ramp outputs can be added with just two additional chips. An optional display/keypad unit allows direct interaction with the sequencer without requiring an external computer. Minor additions also allow simple realizations of other complex instruments, including a precision high-voltage ramp generator for driving spectrum analyzers or piezoelectric positioners, and a low-cost proportional integral differential controller and lock-in amplifier for laser frequency stabilization with about 100 kHz bandwidth.
Progress on a Multichannel, Dual-Mixer Stability Analyzer
NASA Technical Reports Server (NTRS)
Kirk, Albert; Cole, Steven; Stevens, Gary; Tucker, Blake; Greenhall, Charles
2005-01-01
Several documents describe aspects of the continuing development of a multichannel, dual-mixer system for simultaneous characterization of the instabilities of multiple precise, low-noise oscillators. One of the oscillators would be deemed to be a reference oscillator, its frequency would be offset by an amount (100 Hz) much greater than the desired data rate, and each of the other oscillators would be compared with the frequency-offset signal by operation of a combination of hardware and software. A high-rate time-tag counter would collect zero-crossing times of the approximately equal 100-Hz beat notes. The system would effect a combination of interpolation and averaging to process the time tags into low-rate phase residuals at the desired grid times. Circuitry that has been developed since the cited prior article includes an eight-channel timer board to replace an obsolete commercial time-tag counter, plus a custom offset generator, cleanup loop, distribution amplifier, zero-crossing detector, and frequency divider.
An Intrinsic MicroRNA Timer Regulates Progressive Decline in Shoot Regenerative Capacity in Plants
Zhang, Tian-Qi; Lian, Heng; Tang, Hongbo; Dolezal, Karel; Zhou, Chuan-Miao; Yu, Sha; Chen, Juan-Hua; Chen, Qi; Liu, Hongtao; Ljung, Karin
2015-01-01
Plant cells are totipotent and competent to regenerate from differentiated organs. It has been shown that two phytohormones, auxin and cytokinin, play critical roles within this process. As in animals, the regenerative capacity declines with age in plants, but the molecular basis for this phenomenon remains elusive. Here, we demonstrate that an age-regulated microRNA, miR156, regulates shoot regenerative capacity. As a plant ages, the gradual increase in miR156-targeted SQUAMOSA PROMOTER BINDING PROTEIN-LIKE (SPL) transcription factors leads to the progressive decline in shoot regenerative capacity. In old plants, SPL reduces shoot regenerative capacity by attenuating the cytokinin response through binding with the B-type ARABIDOPSIS RESPONSE REGULATORs, which encode the transcriptional activators in the cytokinin signaling pathway. Consistently, the increased amount of exogenous cytokinin complements the reduced shoot regenerative capacity in old plants. Therefore, the recruitment of age cues in response to cytokinin contributes to shoot regenerative competence. PMID:25649435
Safety analysis of urban signalized intersections under mixed traffic.
S, Anjana; M V L R, Anjaneyulu
2015-02-01
This study examined the crash causative factors of signalized intersections under mixed traffic using advanced statistical models. Hierarchical Poisson regression and logistic regression models were developed to predict the crash frequency and severity of signalized intersection approaches. The prediction models helped to develop general safety countermeasures for signalized intersections. The study shows that exclusive left turn lanes and countdown timers are beneficial for improving the safety of signalized intersections. Safety is also influenced by the presence of a surveillance camera, green time, median width, traffic volume, and proportion of two wheelers in the traffic stream. The factors that influence the severity of crashes were also identified in this study. As a practical application, the safe values of deviation of green time provided from design green time, with varying traffic volume, is presented in this study. This is a useful tool for setting the appropriate green time for a signalized intersection approach with variations in the traffic volume. Copyright © 2014 Elsevier Ltd. All rights reserved.
Payload specialist station study: Volume 2, part 3: Program analysis and planning for phase C/D
NASA Technical Reports Server (NTRS)
1976-01-01
The controls and displays (C&D) required at the Orbiter aft-flight deck (AFD) and the core C&D required at the Payload Specialist Station (PSS) are identified in this document. The AFD C&D Concept consists of a multifunction display system (MFDS) and elements of multiuse mission support equipment (MMSE). The MFDS consists of two CRTs, a display electronics unit (DEU), and a keyboard. The MMSE consists of a manual pointing controller (MPC), five digit numeric displays, 10 character alphanumeric legends, event timers, analog meters, rotary and toggle switches. The MMSE may be hardwired to the experiment, or interface with a data bus at the PSS for signal processing. The MFDS has video capability, with alphanumeric and graphic overlay features, on one CRT and alphanumeric and graphic (tricolor) capability on a second CRT. The DEU will have the capability to communicate, via redundant data buses, with both the spacelab experiment and subsystem computers.
Influence of physical parameters on radiation protection and image quality in intra-oral radiology
NASA Astrophysics Data System (ADS)
Belinato, W.; Souza, D. N.
2011-10-01
In the world of diagnostic imaging, radiography is an important supplementary method for dental diagnosis. In radiology, special attention must be paid to the radiological protection of patients and health professionals, and also to image quality for correct diagnosis. In Brazil, the national rules governing the operation of medical and dental radiology were specified in 1998 by the National Sanitary Surveillance Agency, complemented in 2005 by the guide "Medical radiology: security and performance of equipment." In this study, quality control tests were performed in public clinics with dental X-ray equipment in the State of Sergipe, Brazil, with consideration of the physical parameters that influence radiological protection and also the quality of images taken in intra-oral radiography. The accuracy of the exposure time was considered acceptable for equipment with digital timers. Exposure times and focal-spot size variations can lead to increased entrance dose. Increased dose has also been associated with visual processing of radiographic film, which often requires repeating the radiographic examination.
Blood-Pressure Measuring System Gives Accurate Graphic Output
NASA Technical Reports Server (NTRS)
1965-01-01
The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.
The Creation of a CPU Timer for High Fidelity Programs
NASA Technical Reports Server (NTRS)
Dick, Aidan A.
2011-01-01
Using C and C++ programming languages, a tool was developed that measures the efficiency of a program by recording the amount of CPU time that various functions consume. By inserting the tool between lines of code in the program, one can receive a detailed report of the absolute and relative time consumption associated with each section. After adapting the generic tool for a high-fidelity launch vehicle simulation program called MAVERIC, the components of a frequently used function called "derivatives ( )" were measured. Out of the 34 sub-functions in "derivatives ( )", it was found that the top 8 sub-functions made up 83.1% of the total time spent. In order to decrease the overall run time of MAVERIC, a launch vehicle simulation program, a change was implemented in the sub-function "Event_Controller ( )". Reformatting "Event_Controller ( )" led to a 36.9% decrease in the total CPU time spent by that sub-function, and a 3.2% decrease in the total CPU time spent by the overarching function "derivatives ( )".
Di Martino, Giovanni Paolo; Masetti, Matteo; Cavalli, Andrea; Recanatini, Maurizio
2014-11-01
The peptidyl-proyl isomerase Pin1 plays a key role in the regulation of phospho(p)-Ser/Thr-Pro proteins, acting as a molecular timer of the cell cycle. After recognition of these motifs, Pin1 catalyzes the rapid cis-trans isomerization of proline amide bonds of substrates, contributing to maintain the equilibrium between the two conformations. Although a great interest has arisen on this enzyme, its catalytic mechanism has long been debated. Here, the cis-trans isomerization of a model peptide system was investigated by means of umbrella sampling simulations in the Pin1-bound and unbound states. We obtained free energy barriers consistent with experimental data, and identified several enzymatic features directly linked to the acceleration of the prolyl bond isomerization. In particular, an enhanced autocatalysis, the stabilization of perturbed ground state conformations, and the substrate binding in a procatalytic conformation were found as main contributions to explain the lowering of the isomerization free energy barrier. © 2014 Wiley Periodicals, Inc.
Initiation of Phage Infection by Partial Unfolding and Prolyl Isomerization*♦
Hoffmann-Thoms, Stephanie; Weininger, Ulrich; Eckert, Barbara; Jakob, Roman P.; Koch, Johanna R.; Balbach, Jochen; Schmid, Franz X.
2013-01-01
Infection of Escherichia coli by the filamentous phage fd starts with the binding of the N2 domain of the phage gene-3-protein to an F pilus. This interaction triggers partial unfolding of the gene-3-protein, cis → trans isomerization at Pro-213, and domain disassembly, thereby exposing its binding site for the ultimate receptor TolA. The trans-proline sets a molecular timer to maintain the binding-active state long enough for the phage to interact with TolA. We elucidated the changes in structure and local stability that lead to partial unfolding and thus to the activation of the gene-3-protein for phage infection. Protein folding and TolA binding experiments were combined with real-time NMR spectroscopy, amide hydrogen exchange measurements, and phage infectivity assays. In combination, the results provide a molecular picture of how a local unfolding reaction couples with prolyl isomerization not only to generate the activated state of a protein but also to maintain it for an extended time. PMID:23486474
A Verification Method of Inter-Task Cooperation in Embedded Real-time Systems and its Evaluation
NASA Astrophysics Data System (ADS)
Yoshida, Toshio
In software development process of embedded real-time systems, the design of the task cooperation process is very important. The cooperating process of such tasks is specified by task cooperation patterns. Adoption of unsuitable task cooperation patterns has fatal influence on system performance, quality, and extendibility. In order to prevent repetitive work caused by the shortage of task cooperation performance, it is necessary to verify task cooperation patterns in an early software development stage. However, it is very difficult to verify task cooperation patterns in an early software developing stage where task program codes are not completed yet. Therefore, we propose a verification method using task skeleton program codes and a real-time kernel that has a function of recording all events during software execution such as system calls issued by task program codes, external interrupts, and timer interrupt. In order to evaluate the proposed verification method, we applied it to the software development process of a mechatronics control system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levin, J.
A case is reported of a 39-yr-old dentist who realized that his dental x- ray machine had been on for about 90 min. During this time he was near the machine constantly, with his back usually toward the source of radiation. The estimated dose to the back of his head and upper torso was 180 r. The dentist saffered some anxiety, but no acute symptoms of radiation sickness. Physical examination gave negative results. There was no evidence of acute radiation damage. Study of temporal scalp hair revealed an estimated maximum dose received by the hair follicles of approximates 50 tomore » 75 r. The direct technical cause of the accident was a loose washer in the timer mechanism, making contact and completing the switching circuit, thereby causing the unit to go on. It is suggested that dentists and their assistants should wear radiation exposure badges at all times. In addition, equipment shouid be systcmatically and regularly checked so that maximum operating efficiency can be combined with minimum exposure. (P.C.H.)« less
The double LHPR system, a high speed micro- and macroplankton sampler
NASA Astrophysics Data System (ADS)
Williams, R.; Collins, N. R.; Conway, D. V. P.
1983-03-01
A double-net sampling system, consisting of two separate Longhurst-Hardy Plankton Recorders, capable of being towed at speeds up to 3 m s -1 and capturing plankton organisms such as copepod nauplii, with the minimum of damage is described. The systems are mounted in a Lowestoft sampler and connected to 53 and 280-μm mesh nets; both nets are fitted with doors opened by a variable timer unit. The system is suitable for neritic and oceanic deployment. The ratio of the area of the net mouth to the net open area ( R) for the 280-μm net is 9 and for the 53-μm net it is 14 to 121 depending on the nose cone used. The R values are considerably better than those of previous described systems. Examples are given showing how the instrument has been used to resolve spatially the vertical distribution of the nauplii and copepodite stages of Calanus helgolandicus.
NASA Astrophysics Data System (ADS)
Brickman, Jon; Tanchez, Erin; Thomas, Jeanette
2005-09-01
Diel patterns in underwater sounds from five beluga whales (Delphinapterus leucas) and five Pacific white-sided dolphins (Lagenorhynchus obliquidens) housed at John G. Shedd Aquarium in Chicago, IL were studied. Underwater sounds were sampled systematically over 24-h periods by using a battery-operated cassette recorder and an Ithaco 605C hydrophone controlled by a digital timer, which activated every hour and then shut off after 2.5 min. Belugas had 14 sounds and Pacific white-sided dolphins produced 5 sounds. For each species, the use of some sounds was correlated with other sounds. The diel pattern for both species was similar and mostly affected by the presence of humans. Sounds gradually increased after the staff and visitors arrived, peaked during the midday, gradually decreased as closing of the aquarium approached, and was minimal overnight. These data can help identify the best time of day to make recordings and perhaps could be used to examine social, reproductive, or health changes in these captive cetaceans.
Robust and tunable circadian rhythms from differentially sensitive catalytic domains
Phong, Connie; Markson, Joseph S.; Wilhoite, Crystal M.; Rust, Michael J.
2013-01-01
Circadian clocks are ubiquitous biological oscillators that coordinate an organism’s behavior with the daily cycling of the external environment. To ensure synchronization with the environment, the period of the clock must be maintained near 24 h even as amplitude and phase are altered by input signaling. We show that, in a reconstituted circadian system from cyanobacteria, these conflicting requirements are satisfied by distinct functions for two domains of the central clock protein KaiC: the C-terminal autokinase domain integrates input signals through the ATP/ADP ratio, and the slow N-terminal ATPase acts as an input-independent timer. We find that phosphorylation in the C-terminal domain followed by an ATPase cycle in the N-terminal domain is required to form the inhibitory KaiB•KaiC complexes that drive the dynamics of the clock. We present a mathematical model in which this ATPase-mediated delay in negative feedback gives rise to a compensatory mechanism that allows a tunable phase and amplitude while ensuring a robust circadian period. PMID:23277568
ULK3 regulates cytokinetic abscission by phosphorylating ESCRT-III proteins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caballe, Anna; Wenzel, Dawn M.; Agromayor, Monica
The endosomal sorting complexes required for transport (ESCRT) machinery mediates the physical separation between daughter cells during cytokinetic abscission. This process is regulated by the abscission checkpoint, a genome protection mechanism that relies on Aurora B and the ESCRT-III subunit CHMP4C to delay abscission in response to chromosome missegregation. In this study, we show that Unc-51-like kinase 3 (ULK3) phosphorylates and binds ESCRT-III subunits via tandem MIT domains, and thereby, delays abscission in response to lagging chromosomes, nuclear pore defects, and tension forces at the midbody. Our structural and biochemical studies reveal an unusually tight interaction between ULK3 and IST1,more » an ESCRT-III subunit required for abscission. We also demonstrate that IST1 phosphorylation by ULK3 is an essential signal required to sustain the abscission checkpoint and that ULK3 and CHMP4C are functionally linked components of the timer that controls abscission in multiple physiological situations.« less
Kheifets, Aaron; Freestone, David; Gallistel, C R
2017-07-01
In three experiments with mice ( Mus musculus ) and rats (Rattus norvigicus), we used a switch paradigm to measure quantitative properties of the interval-timing mechanism. We found that: 1) Rodents adjusted the precision of their timed switches in response to changes in the interval between the short and long feed latencies (the temporal goalposts). 2) The variability in the timing of the switch response was reduced or unchanged in the face of large trial-to-trial random variability in the short and long feed latencies. 3) The adjustment in the distribution of switch latencies in response to changes in the relative frequency of short and long trials was sensitive to the asymmetry in the Kullback-Leibler divergence. The three results suggest that durations are represented with adjustable precision, that they are timed by multiple timers, and that there is a trial-by-trial (episodic) record of feed latencies in memory. © 2017 Society for the Experimental Analysis of Behavior.
ULK3 regulates cytokinetic abscission by phosphorylating ESCRT-III proteins
Caballe, Anna; Wenzel, Dawn M; Agromayor, Monica; Alam, Steven L; Skalicky, Jack J; Kloc, Magdalena; Carlton, Jeremy G; Labrador, Leticia; Sundquist, Wesley I; Martin-Serrano, Juan
2015-01-01
The endosomal sorting complexes required for transport (ESCRT) machinery mediates the physical separation between daughter cells during cytokinetic abscission. This process is regulated by the abscission checkpoint, a genome protection mechanism that relies on Aurora B and the ESCRT-III subunit CHMP4C to delay abscission in response to chromosome missegregation. In this study, we show that Unc-51-like kinase 3 (ULK3) phosphorylates and binds ESCRT-III subunits via tandem MIT domains, and thereby, delays abscission in response to lagging chromosomes, nuclear pore defects, and tension forces at the midbody. Our structural and biochemical studies reveal an unusually tight interaction between ULK3 and IST1, an ESCRT-III subunit required for abscission. We also demonstrate that IST1 phosphorylation by ULK3 is an essential signal required to sustain the abscission checkpoint and that ULK3 and CHMP4C are functionally linked components of the timer that controls abscission in multiple physiological situations. DOI: http://dx.doi.org/10.7554/eLife.06547.001 PMID:26011858
PHOTOSENSITIVE RELAY CONTROL CIRCUIT
Martin, C.F.
1958-01-14
adapted for the measurement of the time required for an oscillating member to pass through a preselected number of oscillations, after being damped to a certain maximum amplitude of oscillation. A mirror is attached to the moving member and directs light successively to a photocell which is part of a trigger unit and to first and second photocells which are part of a starter unit, as the member swings to its maximum amplitude. The starter and trigger units comprise thyratrons and relays so interconnected that the trigger circuit, although generating a counter pulse, does not register a count in the counter when the light traverses both photocells of the starter unit. When the amplitude of oscillation of the member decreases to where the second photocell is not transversed, the triggei pulse is received by the counter. The counter taen operates to register the desired number of oscillations and initiates and terminates a timer for measuring the time irterval for the preselected number of oscillations.
Caffaro, Federica; Roccato, Michele; Micheletti Cremasco, Margherita; Cavallo, Eugenio
2018-01-25
We aimed at testing a model of the direct and indirect effects of being a part-time farmer on the probability of being involved in an agricultural machinery-related accident, considering the role played by unsafe beliefs and the frequency of use of machinery. Two-hundred and fifty-two Italian men, regular users of agricultural machinery (age: Mean = 45.1 years, standard Deviation = 17.5), were administered a paper-and-pencil questionnaire addressing their relation with work, unsafe beliefs, and previous experience of machinery-related accidents. Being a part-time farmer showed a positive association with unsafe beliefs only among occasional machinery users. Unsafe beliefs in turn showed a positive association with accidents. The study gave a novel contribution to the knowledge of the chain of events connecting part-time farmers with machinery-related accidents. Preventive training interventions targeting part-timer farmers using agricultural machinery just occasionally should be developed.
Caffaro, Federica; Roccato, Michele; Micheletti Cremasco, Margherita; Cavallo, Eugenio
2017-01-01
Objectives: We aimed at testing a model of the direct and indirect effects of being a part-time farmer on the probability of being involved in an agricultural machinery-related accident, considering the role played by unsafe beliefs and the frequency of use of machinery. Methods: Two-hundred and fifty-two Italian men, regular users of agricultural machinery (age: Mean = 45.1 years, standard Deviation = 17.5), were administered a paper-and-pencil questionnaire addressing their relation with work, unsafe beliefs, and previous experience of machinery-related accidents. Results: Being a part-time farmer showed a positive association with unsafe beliefs only among occasional machinery users. Unsafe beliefs in turn showed a positive association with accidents. Conclusions: The study gave a novel contribution to the knowledge of the chain of events connecting part-time farmers with machinery-related accidents. Preventive training interventions targeting part-timer farmers using agricultural machinery just occasionally should be developed. PMID:29093365
Universal sensor interface module (USIM)
NASA Astrophysics Data System (ADS)
King, Don; Torres, A.; Wynn, John
1999-01-01
A universal sensor interface model (USIM) is being developed by the Raytheon-TI Systems Company for use with fields of unattended distributed sensors. In its production configuration, the USIM will be a multichip module consisting of a set of common modules. The common module USIM set consists of (1) a sensor adapter interface (SAI) module, (2) digital signal processor (DSP) and associated memory module, and (3) a RF transceiver model. The multispectral sensor interface is designed around a low-power A/D converted, whose input/output interface consists of: -8 buffered, sampled inputs from various devices including environmental, acoustic seismic and magnetic sensors. The eight sensor inputs are each high-impedance, low- capacitance, differential amplifiers. The inputs are ideally suited for interface with discrete or MEMS sensors, since the differential input will allow direct connection with high-impedance bridge sensors and capacitance voltage sources. Each amplifier is connected to a 22-bit (Delta) (Sigma) A/D converter to enable simultaneous samples. The low power (Delta) (Sigma) converter provides 22-bit resolution at sample frequencies up to 142 hertz (used for magnetic sensors) and 16-bit resolution at frequencies up to 1168 hertz (used for acoustic and seismic sensors). The video interface module is based around the TMS320C5410 DSP. It can provide sensor array addressing, video data input, data calibration and correction. The processor module is based upon a MPC555. It will be used for mode control, synchronization of complex sensors, sensor signal processing, array processing, target classification and tracking. Many functions of the A/D, DSP and transceiver can be powered down by using variable clock speeds under software command or chip power switches. They can be returned to intermediate or full operation by DSP command. Power management may be based on the USIM's internal timer, command from the USIM transceiver, or by sleep mode processing management. The low power detection mode is implemented by monitoring any of the sensor analog outputs at lower sample rates for detection over a software controllable threshold.
Barkin, Shari L.; Finch, Stacia A.; Ip, Edward H.; Scheindlin, Benjamin; Craig, Joseph A.; Steffes, Jennifer; Weiley, Victoria; Slora, Eric; Altman, David; Wasserman, Richard C.
2015-01-01
Objective The objective of this study was to determine whether patients' families' violence-prevention behaviors would be affected by their primary care practitioner's use of a violence-prevention clinical intervention during the routine well-child examination. Methods In this cluster-randomized, controlled trial (2002–2006), 137 Pediatric Research in Office Settings practices were randomly assigned and initiated patient recruitment for either an office-based violence-prevention intervention or a control group (educational handout on literacy promotion provided). Primary caregivers of children who were aged 2 to 11 years and presented for a well-child visit were surveyed at baseline and 1 and 6 months. Practitioners were trained to (1) review a parent previsit summary regarding patient-family behavior and parental concern about media use, discipline strategies, and children's exposure to firearms, (2) counsel using brief principles of motivational interviewing, (3) identify and provide local agency resources for anger and behavior management when indicated, and (4) instruct patient-families on use of tangible tools (minute timers to monitor media time/timeouts and firearm cable locks to store firearms more safely where children live or play). Main outcomes were change over time in self-reported media use < 120 minutes per day, use of timeouts, and use of firearm cable locks. Results Generalized estimating equation analysis revealed a significant effect at 6 months for decreased media use and safer firearm storage. The intervention group compared with the control group showed an increase in limiting media use to < 120 minutes per day. There was no significant effect for timeout use. There was a substantial increase in storing firearms with cable locks for the intervention group versus a decrease for the control group. Conclusions This randomized, controlled trial demonstrated decreased media exposure and increased safe firearm storage as a result of a brief office-based violence-prevention approach. PMID:18595960
Barkin, Shari L; Finch, Stacia A; Ip, Edward H; Scheindlin, Benjamin; Craig, Joseph A; Steffes, Jennifer; Weiley, Victoria; Slora, Eric; Altman, David; Wasserman, Richard C
2008-07-01
The objective of this study was to determine whether patients' families' violence-prevention behaviors would be affected by their primary care practitioner's use of a violence-prevention clinical intervention during the routine well-child examination. In this cluster-randomized, controlled trial (2002-2006), 137 Pediatric Research in Office Settings practices were randomly assigned and initiated patient recruitment for either an office-based violence-prevention intervention or a control group (educational handout on literacy promotion provided). Primary caregivers of children who were aged 2 to 11 years and presented for a well-child visit were surveyed at baseline and 1 and 6 months. Practitioners were trained to (1) review a parent previsit summary regarding patient-family behavior and parental concern about media use, discipline strategies, and children's exposure to firearms, (2) counsel using brief principles of motivational interviewing, (3) identify and provide local agency resources for anger and behavior management when indicated, and (4) instruct patient-families on use of tangible tools (minute timers to monitor media time/timeouts and firearm cable locks to store firearms more safely where children live or play). Main outcomes were change over time in self-reported media use <120 minutes per day, use of timeouts, and use of firearm cable locks. Generalized estimating equation analysis revealed a significant effect at 6 months for decreased media use and safer firearm storage. The intervention group compared with the control group showed an increase in limiting media use to <120 minutes per day. There was no significant effect for timeout use. There was a substantial increase in storing firearms with cable locks for the intervention group versus a decrease for the control group. This randomized, controlled trial demonstrated decreased media exposure and increased safe firearm storage as a result of a brief office-based violence-prevention approach.
Spence, Hollie; Baker, Kevin; Wharton-Smith, Alexandra; Mucunguzi, Akasiima; Matata, Lena; Habte, Tedila; Nanyumba, Diana; Sebsibe, Anteneh; Thany, Thol; Källander, Karin
2017-01-01
Pneumonia heavily contributes to global under-five mortality. Many countries use community case management to detect and treat childhood pneumonia. Community health workers (CHWs) have limited tools to help them assess signs of pneumonia. New respiratory rate (RR) counting devices and pulse oximeters are being considered for this purpose. To explore perspectives of CHWs and national stakeholders regarding the potential usability and scalability of seven devices to aid community assessment of pneumonia signs. Pile sorting was conducted to rate the usability and scalability of 7 different RR counting aids and pulse oximeters amongst 16 groups of participants. Following each pile-sorting session, a focus group discussion (FGD) explored participants' sorting rationale. Purposive sampling was used to select CHWs and national stakeholders with experience in childhood pneumonia and integrated community case management (iCCM) in Cambodia, Ethiopia, Uganda and South Sudan. Pile-sorting data were aggregated for countries and participant groups. FGDs were audio recorded and transcribed verbatim. Translated FGDs transcripts were coded in NVivo 10 and analysed using thematic content analysis. Comparative analysis was performed between countries and groups to identify thematic patterns. CHWs and national stakeholders across the four countries perceived the acute respiratory infection (ARI) timer and fingertip pulse oximeter as highly scalable and easy for CHWs to use. National stakeholders were less receptive to new technologies. CHWs placed greater priority on device acceptability to caregivers and children. Both groups felt that heavy reliance on electricity reduced potential scalability and usability in rural areas. Device simplicity, affordability and sustainability were universally valued. CHWs and national stakeholders prioritise different device characteristics according to their specific focus of work. The views of all relevant stakeholders, including health workers, policy makers, children and parents, should be considered in future policy decisions, research and development regarding suitable pneumonia diagnostic aids for community use.
Drosophila embryogenesis scales uniformly across temperature in developmentally diverse species.
Kuntz, Steven G; Eisen, Michael B
2014-04-01
Temperature affects both the timing and outcome of animal development, but the detailed effects of temperature on the progress of early development have been poorly characterized. To determine the impact of temperature on the order and timing of events during Drosophila melanogaster embryogenesis, we used time-lapse imaging to track the progress of embryos from shortly after egg laying through hatching at seven precisely maintained temperatures between 17.5 °C and 32.5 °C. We employed a combination of automated and manual annotation to determine when 36 milestones occurred in each embryo. D. melanogaster embryogenesis takes [Formula: see text]33 hours at 17.5 °C, and accelerates with increasing temperature to a low of 16 hours at 27.5 °C, above which embryogenesis slows slightly. Remarkably, while the total time of embryogenesis varies over two fold, the relative timing of events from cellularization through hatching is constant across temperatures. To further explore the relationship between temperature and embryogenesis, we expanded our analysis to cover ten additional Drosophila species of varying climatic origins. Six of these species, like D. melanogaster, are of tropical origin, and embryogenesis time at different temperatures was similar for them all. D. mojavensis, a sub-tropical fly, develops slower than the tropical species at lower temperatures, while D. virilis, a temperate fly, exhibits slower development at all temperatures. The alpine sister species D. persimilis and D. pseudoobscura develop as rapidly as tropical flies at cooler temperatures, but exhibit diminished acceleration above 22.5 °C and have drastically slowed development by 30 °C. Despite ranging from 13 hours for D. erecta at 30 °C to 46 hours for D. virilis at 17.5 °C, the relative timing of events from cellularization through hatching is constant across all species and temperatures examined here, suggesting the existence of a previously unrecognized timer controlling the progress of embryogenesis that has been tuned by natural selection as each species diverges.
FPGA-based Upgrade to RITS-6 Control System, Designed with EMP Considerations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harold D. Anderson, John T. Williams
2009-07-01
The existing control system for the RITS-6, a 20-MA 3-MV pulsed-power accelerator located at Sandia National Laboratories, was built as a system of analog switches because the operators needed to be close enough to the machine to hear pulsed-power breakdowns, yet the electromagnetic pulse (EMP) emitted would disable any processor-based solutions. The resulting system requires operators to activate and deactivate a series of 110-V relays manually in a complex order. The machine is sensitive to both the order of operation and the time taken between steps. A mistake in either case would cause a misfire and possible machine damage. Basedmore » on these constraints, a field-programmable gate array (FPGA) was chosen as the core of a proposed upgrade to the control system. An FPGA is a series of logic elements connected during programming. Based on their connections, the elements can mimic primitive logic elements, a process called synthesis. The circuit is static; all paths exist simultaneously and do not depend on a processor. This should make it less sensitive to EMP. By shielding it and using good electromagnetic interference-reduction practices, it should continue to operate well in the electrically noisy environment. The FPGA has two advantages over the existing system. In manual operation mode, the synthesized logic gates keep the operators in sequence. In addition, a clock signal and synthesized countdown circuit provides an automated sequence, with adjustable delays, for quickly executing the time-critical portions of charging and firing. The FPGA is modeled as a set of states, each state being a unique set of values for the output signals. The state is determined by the input signals, and in the automated segment by the value of the synthesized countdown timer, with the default mode placing the system in a safe configuration. Unlike a processor-based system, any system stimulus that results in an abort situation immediately executes a shutdown, with only a tens-of-nanoseconds delay to propagate across the FPGA. This paper discusses the design, installation, and testing of the proposed system upgrade, including failure statistics and modifications to the original design.« less
Asl, Leila Kheibarshekan; Dhondt, Stijn; Boudolf, Véronique; Beemster, Gerrit T S; Beeckman, Tom; Inzé, Dirk; Govaerts, Willy; De Veylder, Lieven
2011-08-01
To efficiently capture sunlight for photosynthesis, leaves typically develop into a flat and thin structure. This development is driven by cell division and expansion, but the individual contribution of these processes is currently unknown, mainly because of the experimental difficulties to disentangle them in a developing organ, due to their tight interconnection. To circumvent this problem, we built a mathematic model that describes the possible division patterns and expansion rates for individual epidermal cells. This model was used to fit experimental data on cell numbers and sizes obtained over time intervals of 1 d throughout the development of the first leaf pair of Arabidopsis (Arabidopsis thaliana). The parameters were obtained by a derivative-free optimization method that minimizes the differences between the predicted and experimentally observed cell size distributions. The model allowed us to calculate probabilities for a cell to divide into guard or pavement cells, the maximum size at which it can divide, and its average cell division and expansion rates at each point during the leaf developmental process. Surprisingly, average cell cycle duration remained constant throughout leaf development, whereas no evidence for a maximum cell size threshold for cell division of pavement cells was found. Furthermore, the model predicted that neighboring cells of different sizes within the epidermis expand at distinctly different relative rates, which could be verified by direct observations. We conclude that cell division seems to occur independently from the status of cell expansion, whereas the cell cycle might act as a timer rather than as a size-regulated machinery.
Molteni, Matteo; Ferri, Fabio
2016-11-01
A 10 ns time resolution, multi-tau software correlator, capable of computing simultaneous autocorrelation (A-A, B-B) and cross (A-B) correlation functions at count rates up to ∼10 MHz, with no data loss, has been developed in LabVIEW and C++ by using the National Instrument timer/counterboard (NI PCIe-6612) and a fast Personal Computer (PC) (Intel Core i7-4790 Processor 3.60 GHz ). The correlator works by using two algorithms: for large lag times (τ ≳ 1 μs), a classical time-mode scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ ≲ 1 μs a photon-mode (PM) scheme is adopted and the correlation function is retrieved from the sequence of the photon arrival times. Single auto- and cross-correlation functions can be processed online in full real time up to count rates of ∼1.8 MHz and ∼1.2 MHz, respectively. Two autocorrelation (A-A, B-B) and a cross correlation (A-B) functions can be simultaneously processed in full real time only up to count rates of ∼750 kHz. At higher count rates, the online processing takes place in a delayed modality, but with no data loss. When tested with simulated correlation data and latex spheres solutions, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.
NASA Tech Briefs, November 2003
NASA Technical Reports Server (NTRS)
2003-01-01
Topics covered include: Computer Program Recognizes Patterns in Time-Series Data; Program for User-Friendly Management of Input and Output Data Sets; Noncoherent Tracking of a Source of a Data-Modulated Signal; Software for Acquiring Image Data for PIV; Detecting Edges in Images by Use of Fuzzy Reasoning; A Timer for Synchronous Digital Systems; Prototype Parts of a Digital Beam-Forming Wide-Band Receiver; High-Voltage Droplet Dispenser; Network Extender for MIL-STD-1553 Bus; MMIC HEMT Power Amplifier for 140 to 170 GHz; Piezoelectric Diffraction-Based Optical Switches; Numerical Modeling of Nanoelectronic Devices; Organizing Diverse, Distributed Project Information; Eigensolver for a Sparse, Large Hermitian Matrix; Modified Polar-Format Software for Processing SAR Data; e-Stars Template Builder; Software for Acoustic Rendering; Functionally Graded Nanophase Beryllium/Carbon Composites; Thin Thermal-Insulation Blankets for Very High Temperatures; Prolonging Microgravity on Parabolic Airplane Flights; Device for Locking a Control Knob; Cable-Dispensing Cart; Foam Sensor Structures Would be Self-Deployable and Survive Hard Landings; Real-Gas Effects on Binary Mixing Layers; Earth-Space Link Attenuation Estimation via Ground Radar Kdp; Wedge Heat-Flux Indicators for Flash Thermography; Measuring Diffusion of Liquids by Common-Path Interferometry; Zero-Shear, Low-Disturbance Optical Delay Line; Whispering-Gallery Mode-Locked Lasers; Spatial Light Modulators as Optical Crossbar Switches; Update on EMD and Hilbert-Spectra Analysis of Time Series; Quad-Tree Visual-Calculus Analysis of Satellite Coverage; Dyakonov-Perel Effect on Spin Dephasing in n-Type GaAs; Update on Area Production in Mixing of Supercritical Fluids; and Quasi-Sun-Pointing of Spacecraft Using Radiation Pressure.
NASA Astrophysics Data System (ADS)
Molteni, Matteo; Ferri, Fabio
2016-11-01
A 10 ns time resolution, multi-tau software correlator, capable of computing simultaneous autocorrelation (A-A, B-B) and cross (A-B) correlation functions at count rates up to ˜10 MHz, with no data loss, has been developed in LabVIEW and C++ by using the National Instrument timer/counterboard (NI PCIe-6612) and a fast Personal Computer (PC) (Intel Core i7-4790 Processor 3.60 GHz ). The correlator works by using two algorithms: for large lag times (τ ≳ 1 μs), a classical time-mode scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ ≲ 1 μs a photon-mode (PM) scheme is adopted and the correlation function is retrieved from the sequence of the photon arrival times. Single auto- and cross-correlation functions can be processed online in full real time up to count rates of ˜1.8 MHz and ˜1.2 MHz, respectively. Two autocorrelation (A-A, B-B) and a cross correlation (A-B) functions can be simultaneously processed in full real time only up to count rates of ˜750 kHz. At higher count rates, the online processing takes place in a delayed modality, but with no data loss. When tested with simulated correlation data and latex spheres solutions, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.
NASA Astrophysics Data System (ADS)
Weng, M. H.; Clark, D. T.; Wright, S. N.; Gordon, D. L.; Duncan, M. A.; Kirkham, S. J.; Idris, M. I.; Chan, H. K.; Young, R. A. R.; Ramsay, E. P.; Wright, N. G.; Horsfall, A. B.
2017-05-01
A high manufacturing readiness level silicon carbide (SiC) CMOS technology is presented. The unique process flow enables the monolithic integration of pMOS and nMOS transistors with passive circuit elements capable of operation at temperatures of 300 °C and beyond. Critical to this functionality is the behaviour of the gate dielectric and data for high temperature capacitance-voltage measurements are reported for SiO2/4H-SiC (n and p type) MOS structures. In addition, a summary of the long term reliability for a range of structures including contact chains to both n-type and p-type SiC, as well as simple logic circuits is presented, showing function after 2000 h at 300 °C. Circuit data is also presented for the performance of digital logic devices, a 4 to 1 analogue multiplexer and a configurable timer operating over a wide temperature range. A high temperature micro-oven system has been utilised to enable the high temperature testing and stressing of units assembled in ceramic dual in line packages, including a high temperature small form-factor SiC based bridge leg power module prototype, operated for over 1000 h at 300 °C. The data presented show that SiC CMOS is a key enabling technology in high temperature integrated circuit design. In particular it provides the ability to realise sensor interface circuits capable of operating above 300 °C, accommodate shifts in key parameters enabling deployment in applications including automotive, aerospace and deep well drilling.
Asl, Leila Kheibarshekan; Dhondt, Stijn; Boudolf, Véronique; Beemster, Gerrit T.S.; Beeckman, Tom; Inzé, Dirk; Govaerts, Willy; De Veylder, Lieven
2011-01-01
To efficiently capture sunlight for photosynthesis, leaves typically develop into a flat and thin structure. This development is driven by cell division and expansion, but the individual contribution of these processes is currently unknown, mainly because of the experimental difficulties to disentangle them in a developing organ, due to their tight interconnection. To circumvent this problem, we built a mathematic model that describes the possible division patterns and expansion rates for individual epidermal cells. This model was used to fit experimental data on cell numbers and sizes obtained over time intervals of 1 d throughout the development of the first leaf pair of Arabidopsis (Arabidopsis thaliana). The parameters were obtained by a derivative-free optimization method that minimizes the differences between the predicted and experimentally observed cell size distributions. The model allowed us to calculate probabilities for a cell to divide into guard or pavement cells, the maximum size at which it can divide, and its average cell division and expansion rates at each point during the leaf developmental process. Surprisingly, average cell cycle duration remained constant throughout leaf development, whereas no evidence for a maximum cell size threshold for cell division of pavement cells was found. Furthermore, the model predicted that neighboring cells of different sizes within the epidermis expand at distinctly different relative rates, which could be verified by direct observations. We conclude that cell division seems to occur independently from the status of cell expansion, whereas the cell cycle might act as a timer rather than as a size-regulated machinery. PMID:21693673
Hewett, Donnel Foster; Knopf, Adolph; Calkins, Frank C.; Pratt, Walden P.
1997-01-01
In December, 1962, 81-year-old Donnel Foster Hewett hosted a dinner party for what was then the “younger crop”of U.S. Geological Survey geologists in Menlo Park, California. His aim was to give them the benefit of some collective wisdom about what life in the Survey was like in the “good old days,” with particular attention paid to the personalities of some of the men who had played prominent roles in the Survey's development. To this end he recruited two other Survey old-timers: Adolph Knopf (80), a Visiting Professor at nearby Stanford University, and Frank Calkins (84), a USGS Annuitant in the Menlo Park headquarters. Following a convivial dinner, these three distinguished gentlemen delivered their remarks to an appreciative and responsive audience. In an act of great foresight, someone, perhaps Hewett himself, had arranged to have the proceedings tape-recorded. Walden P. Pratt, of the USGS in Denver, Colo., obtained a copy of the tape and transcribed it.
Dynamic resource allocation scheme for distributed heterogeneous computer systems
NASA Technical Reports Server (NTRS)
Liu, Howard T. (Inventor); Silvester, John A. (Inventor)
1991-01-01
This invention relates to a resource allocation in computer systems, and more particularly, to a method and associated apparatus for shortening response time and improving efficiency of a heterogeneous distributed networked computer system by reallocating the jobs queued up for busy nodes to idle, or less-busy nodes. In accordance with the algorithm (SIDA for short), the load-sharing is initiated by the server device in a manner such that extra overhead in not imposed on the system during heavily-loaded conditions. The algorithm employed in the present invention uses a dual-mode, server-initiated approach. Jobs are transferred from heavily burdened nodes (i.e., over a high threshold limit) to low burdened nodes at the initiation of the receiving node when: (1) a job finishes at a node which is burdened below a pre-established threshold level, or (2) a node is idle for a period of time as established by a wakeup timer at the node. The invention uses a combination of the local queue length and the local service rate ratio at each node as the workload indicator.
Chemical vapor deposition growth
NASA Technical Reports Server (NTRS)
Ruth, R. P.; Manasevit, H. M.; Johnson, R. E.; Kenty, J. L.; Moudy, L. A.; Simpson, W. I.; Yang, J. J.
1976-01-01
A laboratory type CVD reactor system with a vertical deposition chamber and sample pedestal heated by an external RF coil has been extensively modified by installation of mass flow controllers, automatic process sequence timers, and special bellows-sealed air-operated valves for overall improved performance. Various film characterization procedures, including classical metallography, SEM analyses, X ray diffraction analyses, surface profilometry, and electrical measurements (resistivity, carrier concentration, mobility, spreading resistance profiles, and minority-carrier lifetime by the C-V-t method) area used to correlate Si sheet properties with CVD parameters and substrate properties. Evaluation procedures and measurements are given. Experimental solar cell structures were made both in epitaxial Si sheet (on sapphire substrates) and in polycrystalline material on alumina substrates, the former to provide an indication of what might be an upper limit on performance of the latter. Preliminary results are given, as obtained in cell structures not specially designed to allow for the unique properties of the sheet material, and fabricated in material known to be far from optimum for photovoltaic performance. Low power conversion efficiencies have been obtained in the epitaxial as well as the polycrystalline Si sheet.
Somerson, Jeremy S; Rowley, David; Kennedy, Chad; Buttacavoli, Frank; Agarwal, Animesh
2014-07-01
To compare the time required for proximal locking screw placement between a standard freehand technique and the navigated technique, and to quantify the reduction in ionizing radiation exposure. A fresh frozen cadaver model was used for 48 proximal interlocking screw procedures. Each procedure consisted of insertion of 2 anteroposterior locking screws. Standard fluoroscopic technique was used for 24 procedures, and an electromagnetic navigation system was used for the remaining 24 procedures. Procedure duration was recorded using an electronic timer and radiation doses were documented. Mean total insertion time for both proximal interlocking screws was 405 ± 165.7 seconds with the freehand technique and 311 ± 78.3 seconds in the navigation group (P = 0.002). All procedures resulted in successful locking screw placement. Mean ionizing radiation exposure time for proximal locking was 29.5 ± 12.8 seconds. Proximal locking screw insertion using the navigation technique evaluated in this work was significantly faster than the standard fluoroscopic method. The navigated technique is effective and has the potential to prevent ionizing radiation exposure.
NASA Astrophysics Data System (ADS)
Leifer, R.; Sommers, K. G.; Guggenheim, S. F.; Fisenne, I.
1981-02-01
An ultra-clean, low volume gas sampling system (CLASS), flown aboard a high altitude aircraft (WB-57F), and providing information on stratospheric trace gases is presented. Attention is given to the instrument design and the electronic control design. Since remote operation is mandatory on the WB-57F, a servo pressure transducer, electrical pressure switch for automatic shutdown, and a mechanical safety relief valve were installed on the sampling manifold, indicated on the CLASS flow chart. The electronic control system consists of hermetically sealed solid state timers, relays, and a stepping switch, for controlling the compressor pump and solenoid valves. In designing the automatic control system, vibration, shock, acceleration, extreme low temperature, and aircraft safety were important considerations. CLASS was tested on three separate occasions, and tables of analytical data from these flights are presented. Readiness capability was demonstrated when the Mount St. Helens eruption plume of May 18, 1980, was intercepted, and it was concluded that no large injection of Rn-222 entered the stratosphere or troposphere from the eruption.
Motor actuated vacuum door. [for photography from sounding rockets
NASA Technical Reports Server (NTRS)
Hanagud, A. V.
1986-01-01
Doors that allow scientific instruments to record and retrieve the observed data are often required to be designed and installed as a part of sounding rocket hardware. The motor-actuated vacuum door was designed to maintain a medium vacuum of the order of 0.0001 torr or better while closed, and to provide an opening 15 inches long x 8.5 inches wide while open for cameras to image Halley's comet. When the electric motor receives the instruction to open the door through the payload battery, timer, and relay circuit, the first operation is to unlock the door. After unlatching, the torque transmitted by the motor to the main shaft through the links opens the door. A microswitch actuator, which rides on the linear motion conversion mechanism, is adjusted to trip the limit switch at the end of the travel. The process is repeated in the reverse order to close the door. 'O' rings are designed to maintain the seal. Door mechanisms similar to the one described have flown on Aerobee 17.018 and Black Brant 27.047 payloads.
Observations of environmental change in Grand Canyon, Arizona
Webb, Robert H.; Melis, Theodore S.; Valdez, Richard A.
2002-01-01
Few scientific data have been collected on pre-dam conditions of the Colorado River corridor through Grand Canyon National Park. Using historical diaries, interviews with pre-dam river runners (referred to as the ?Old Timers?), and historical scientific data and observations, we compiled anecdotal information on environmental change in Grand Canyon. The most significant changes are the: lowering of water temperature in the river, near-elimination of heavily sediment-laden flows, erosion of sand bars, invasion of non-native tamarisk trees, reduction in driftwood, development of marshes, increase in non-native fish at the expense of native fishes, and increase in water bird populations. In addition, few debris flows were observed before closure of Glen Canyon Dam, which might suggests that the frequency of debris flows in Grand Canyon has increased. Other possible changes include decreases in bat populations and increases in swallow and bighorn sheep populations, although the evidence is anecdotal and inconclusive. These results provide a perspective on managing the Colorado River that may allow differentiation of the effects of Glen Canyon Dam from other processes of change.
NASA Astrophysics Data System (ADS)
Forbes, Anne; Skamp, Keith
2016-02-01
MyScience is a primary science education initiative in which being in a community of practice is integral to the learning process. In this initiative, stakeholder groups—primary teachers, primary students and mentors—interact around the `domain' of `investigating scientifically'. This paper builds on three earlier publications and interprets the findings of the views of four secondary science teachers and five year 9 secondary science students who were first-timer participants—as mentors—in MyScience. Perceptions of these mentors' interactions with primary students were analysed using attributes associated with both `communities of practice' and the `nature of science'. Findings reveal that participation in MyScience changed secondary science teachers' views and practices about how to approach the teaching of science in secondary school and fostered primary-secondary links. Year 9 students positively changed their views about secondary school science and confidence in science through participation as mentors. Implications for secondary science teaching and learning through participation in primary school community of science practice settings are discussed.
Jiang, Feng; Bai, Jingfeng; Chen, Yazhu
2005-08-01
Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.
Foresight beyond the very next event: four-year-olds can link past and deferred future episodes
Redshaw, Jonathan; Suddendorf, Thomas
2013-01-01
Previous experiments have demonstrated that by 4 years of age children can use information from a past episode to solve a problem for the very next future episode. However, it remained unclear whether 4-year-olds can similarly use such information to solve a problem for a more removed future episode that is not of immediate concern. In the current study we introduced 4-year-olds to problems in one room before taking them to another room and distracting them for 15 min. The children were then offered a choice of items to place into a bucket that was to be taken back to the first room when a 5-min sand-timer had completed a cycle. Across two conceptually distinct domains, the children placed the item that could solve the deferred future problem above chance level. This result demonstrates that by 48 months many children can recall a problem from the past and act in the present to solve that problem for a deferred future episode. We discuss implications for theories about the nature of episodic foresight. PMID:23847575
Biorhythms on cellular and organismic level (introduction).
Mergenhagen, D
1989-01-01
The regular change of day and night, of light and darkness during millions of years has strongly affected the development of life on earth. Many organisms adapted themselves to this environmental condition and, finally, evolved an endogenous timer which usually is in phase with the earth's rotation and causes many functions to perform one oscillation per day. Such circadian rhythms (derived from circa dies i.e. about 1 day) were found in almost all classes of plants and animals, and even in protozoans. They persist in a constant environment and, therefore, are independent of any known external trigger signals. Since even unicells perform circadian rhythms which are similar to those observed in highly developed multicellular organisms many scientists favor the existence of a basic mechanism common to all kinds of biological clocks that is located somewhere in the single cell and probably comprises many different biochemical reactions. One purpose of this topical meeting was to discuss how organisms respond to the absence of gravity and terrestrial zeitgeber and how they may react to the imposing of hypergravity fields. Another aim was to develop model-mechanisms appropriate to describe these responses.
2018-01-01
ABSTRACT Long-germ insects, such as the fruit fly Drosophila melanogaster, pattern their segments simultaneously, whereas short-germ insects, such as the beetle Tribolium castaneum, pattern their segments sequentially, from anterior to posterior. Although the two modes of segmentation at first appear quite distinct, much of this difference might simply reflect developmental heterochrony. We now show here that, in both Drosophila and Tribolium, segment patterning occurs within a common framework of sequential Caudal, Dichaete and Odd-paired expression. In Drosophila, these transcription factors are expressed like simple timers within the blastoderm, whereas in Tribolium they form wavefronts that sweep from anterior to posterior across the germband. In Drosophila, all three are known to regulate pair-rule gene expression and influence the temporal progression of segmentation. We propose that these regulatory roles are conserved in short-germ embryos, and that therefore the changing expression profiles of these genes across insects provide a mechanistic explanation for observed differences in the timing of segmentation. In support of this hypothesis, we demonstrate that Odd-paired is essential for segmentation in Tribolium, contrary to previous reports. PMID:29724758
Apparatus and method for biological purification of waste
Lucido, John A.; Keenan, Daniel; Premuzic, Eugene T.; Lin, Mow S.; Shelenkova, Ludmila
1998-11-24
An apparatus is disclosed for containing a microorganism culture in an active exponential growth and delivering a supply of microorganisms to an environment containing wastes for bio-augmenting the biodegradation of the wastes. The apparatus comprises a bioreactor and an operably connected controller. The bioreactor has a bioreactor chamber for containing a supply of microorganisms, a second chamber for containing a supply of water and inorganic nutrients, and a third chamber for containing a supply of organic nutrients. The bioreactor is operably connected to the controller in which a first pump is operably connected in fluid communication between the bioreactor chamber and the second chamber and third chamber, and a second pump is operably connected in fluid communication between the bioreactor chamber and the environment containing wastes to be biodegraded. The controller further includes a timer and regulator operably connected to the first and second pumps to effectively maintain the microorganisms in exponential growth in the bioreactor chamber and to deliver microorganisms to an environment to be treated. Also, disclosed is a method for bio-augmenting the biodegradation of wastes.
Apparatus and method for biological purification of waste
Lucido, J.A.; Keenan, D.; Premuzic, E.T.; Lin, M.S.; Shelenkova, L.
1998-11-24
An apparatus is disclosed for containing a microorganism culture in an active exponential growth and delivering a supply of microorganisms to an environment containing wastes for bio-augmenting the biodegradation of the wastes. The apparatus comprises a bioreactor and an operably connected controller. The bioreactor has a bioreactor chamber for containing a supply of microorganisms, a second chamber for containing a supply of water and inorganic nutrients, and a third chamber for containing a supply of organic nutrients. The bioreactor is operably connected to the controller in which a first pump is operably connected in fluid communication between the bioreactor chamber and the second chamber and third chamber, and a second pump is operably connected in fluid communication between the bioreactor chamber and the environment containing wastes to be biodegraded. The controller further includes a timer and regulator operably connected to the first and second pumps to effectively maintain the microorganisms in exponential growth in the bioreactor chamber and to deliver microorganisms to an environment to be treated. Also, disclosed is a method for bio-augmenting the biodegradation of wastes. 7 figs.
Method for biological purification
Lucido, John A.; Keenan, Daniel; Premuzic, Eugene T.; Lin, Mow S.; Shelenkova, Ludmila
2001-03-27
An apparatus is disclosed for containing a microorganism culture in an active exponential growth and delivering a supply of microorganisms to an environment containing wastes for bio-augmenting the biodegradation of the wastes. The apparatus comprises a bioreactor and an operably connected controller. The bioreactor has a bioreactor chamber for containing a supply of microorganisms, a second chamber for containing a supply of water and inorganic nutrients, and a third chamber for containing a supply of organic nutrients. The bioreactor is operably connected to the controller in which a first pump is operably connected in fluid communication between the bioreactor chamber and the second chamber and third chamber, and a second pump is operably connected in fluid communication between the bioreactor chamber and the environment containing wastes to be biodegraded. The controller further includes a timer and regulator operably connected to the first and second pumps to effectively maintain the microorganisms in exponential growth in the bioreactor chamber and to deliver microorganisms to an environment to be treated. Also, disclosed is a method for bio-augmenting the biodegradation of wastes.
Support for Diagnosis of Custom Computer Hardware
NASA Technical Reports Server (NTRS)
Molock, Dwaine S.
2008-01-01
The Coldfire SDN Diagnostics software is a flexible means of exercising, testing, and debugging custom computer hardware. The software is a set of routines that, collectively, serve as a common software interface through which one can gain access to various parts of the hardware under test and/or cause the hardware to perform various functions. The routines can be used to construct tests to exercise, and verify the operation of, various processors and hardware interfaces. More specifically, the software can be used to gain access to memory, to execute timer delays, to configure interrupts, and configure processor cache, floating-point, and direct-memory-access units. The software is designed to be used on diverse NASA projects, and can be customized for use with different processors and interfaces. The routines are supported, regardless of the architecture of a processor that one seeks to diagnose. The present version of the software is configured for Coldfire processors on the Subsystem Data Node processor boards of the Solar Dynamics Observatory. There is also support for the software with respect to Mongoose V, RAD750, and PPC405 processors or their equivalents.
Gram staining with an automatic machine.
Felek, S; Arslan, A
1999-01-01
This study was undertaken to develop a new Gram-staining machine controlled by a micro-controller and to investigate the quality of slides that were stained in the machine. The machine was designed and produced by the authors. It uses standard 220 V AC. Staining, washing, and drying periods are controlled by a timer built in the micro-controller. A software was made that contains a certain algorithm and time intervals for the staining mode. One-hundred and forty smears were prepared from Escherichia coli, Staphylococcus aureus, Neisseria sp., blood culture, trypticase soy broth, direct pus and sputum smears for comparison studies. Half of the slides in each group were stained with the machine, the other half by hand and then examined by four different microbiologists. Machine-stained slides had a higher clarity and less debris than the hand-stained slides (p < 0.05). In hand-stained slides, some Gram-positive organisms showed poor Gram-positive staining features (p < 0.05). In conclusion, we suggest that Gram staining with the automatic machine increases the staining quality and helps to decrease the work load in a busy diagnostic laboratory.
Ode, Koji L; Ukai, Hideki; Susaki, Etsuo A; Narumi, Ryohei; Matsumoto, Katsuhiko; Hara, Junko; Koide, Naoshi; Abe, Takaya; Kanemaki, Masato T; Kiyonari, Hiroshi; Ueda, Hiroki R
2017-01-05
To conduct comprehensive characterization of molecular properties in organisms, we established an efficient method to produce knockout (KO)-rescue mice within a single generation. We applied this method to produce 20 strains of almost completely embryonic stem cell (ESC)-derived mice ("ES mice") rescued with wild-type and mutant Cry1 gene under a Cry1 -/- :Cry2 -/- background. A series of both phosphorylation-mimetic and non-phosphorylation-mimetic CRY1 mutants revealed that multisite phosphorylation of CRY1 can serve as a cumulative timer in the mammalian circadian clock. KO-rescue ES mice also revealed that CRY1-PER2 interaction confers a robust circadian rhythmicity in mice. Surprisingly, in contrast to theoretical predictions from canonical transcription/translation feedback loops, the residues surrounding the flexible P loop and C-lid domains of CRY1 determine circadian period without changing the degradation rate of CRY1. These results suggest that CRY1 determines circadian period through both its degradation-dependent and -independent pathways. Copyright © 2017 Elsevier Inc. All rights reserved.
The potential impact of hydrogen energy use on the atmosphere
NASA Astrophysics Data System (ADS)
van Ruijven, B. J.; Lamarque, J. F.; van Vuuren, D. P.; Kram, T.; Eerens, H.
2009-04-01
Energy models show very different trajectories for future energy systems (partly as function of future climate policy). One possible option is a transition towards a hydrogen-based energy system. The potential impact of such hydrogen economy on atmospheric emissions is highly uncertain. On the one hand, application of hydrogen in clean fuel cells reduces emissions of local air pollutants, like SOx and NOx. On the other hand, emissions of hydrogen from system leakages are expected to change the atmospheric concentrations and behaviour (see also Price et al., 2007; Sanderson et al., 2003; Schultz et al., 2003; Tromp et al., 2003). The uncertainty arises from several sources: the expected use of hydrogen, the intensity of leakages and emissions, and the atmospheric chemical behaviour of hydrogen. Existing studies to the potential impacts of a hydrogen economy on the atmosphere mostly use hydrogen emission scenarios that are based on simple assumptions. This research combines two different modelling efforts to explore the range of impacts of hydrogen on atmospheric chemistry. First, the potential role of hydrogen in the global energy system and the related emissions of hydrogen and other air pollutants are derived from the global energy system simulation model TIMER (van Vuuren, 2007). A set of dedicated scenarios on hydrogen technology development explores the most pessimistic and optimistic cases for hydrogen deployment (van Ruijven et al., 2008; van Ruijven et al., 2007). These scenarios are combined with different assumptions on hydrogen emission factors. Second, the emissions from the TIMER model are linked to the NCAR atmospheric model (Lamarque et al., 2005; Lamarque et al., 2008), in order to determine the impacts on atmospheric chemistry. By combining an energy system model and an atmospheric model, we are able to consistently explore the boundaries of both hydrogen use, emissions and impacts on atmospheric chemistry. References: Lamarque, J.-F., Kiehl, J. T., Hess, P. G., Collins, W. D., Emmons, L. K., Ginoux, P., Luo, C. and Tie, X. X. (2005). "Response of a coupled chemistry-climate model to changes in aerosol emissions: Global impact on the hydrological cycle and the tropospheric burdens of OH, ozone and NOx." Geophysical Research Letters 32(16). Lamarque, J.-F., Kinnison, D. E., Hess, P. G. and Vitt, F. (2008). "Simulated lower stratospheric trends between 1970 and 2005: identifying the role of climate and composition changes." Journal of Geophysical Research 113(D12301). Price, H., Jaegle, L., Rice, A., Quay, P., Novelli, P. C. and Gammon, R. (2007). "Global budget of molecular hydrogen and its deuterium content: constraints from ground station, cruise, and aircraft observations." Journal of Geophysical Research 112(D22108). Sanderson, M. G., Collins, W. J., Derwent, R. G. and Johnson, C. E. (2003). "Simulation of Global Hydrogen Levels Using a Lagrangian Three-Dimensional Model." Journal of Atmospheric Chemistry 46(1): 15-28. Schultz, M. G., Diehl, T., Brasseur, G. P. and Zittel, W. (2003). "Air Pollution and Climate-Forcing Impacts of a Global Hydrogen Economy." Science 302(5645): 624-627. Tromp, T. K., Shia, R. L., Allen, M., Eiler, J. M. and Yung, Y. L. (2003). "Potential environmental impact of a hydrogen economy on the stratosphere." Science 300(5626): 1740-1742. van Ruijven, B., Hari, L., van Vuuren, D. P. and de Vries, B. (2008). "The potential role of hydrogen in India and Western Europe." Energy Policy 36(5): 1649-1665. van Ruijven, B., van Vuuren, D. P. and de Vries, B. (2007). "The potential role of hydrogen in energy systems with and without climate policy." International Journal of Hydrogen Energy 32(12): 1655-1672. van Vuuren, D. P. (2007). Energy systems and climate policy. Dept. of Science, Technology and Society, Faculty of Science. Utrecht, Utrecht University: 326.
New controller for functional electrical stimulation systems.
Fisekovic, N; Popovic, D B
2001-07-01
A novel, self-contained controller for functional electrical stimulation systems has been designed. The development was motivated by the need to have a general purpose, easy to use controller capable of stimulating many muscle groups, thus restoring complex motor functions (e.g. standing, walking, reaching, and grasping). The designed controller can regulate the frequency, pulse duration, and charge balance on up to 16 channels, and execute pre-programmed and sensory-driven control operations. The controller supports up to eight analog and six digital sensors, and comprises a memory block for including history of the sensory data (time series). Five independent timers provide the basis for the multi-modal and multi-level control of movement. The PC compatible interface is realised via an IR serial communication channel. The PC based software is user friendly and fully menu driven. This paper also presents a case study where the controller was implemented to restore walking in a paraplegic subject. The assistive system comprised the novel controller, the power and output stages of an eight-channel FES system (IEEE Trans Rehabil Eng, TRE-2 (1994) 234), ankle-foot orthoses, and a rolling walker. Stimulation was applied with surface electrodes positioned over the motoneurons that innervate muscles responsible for the hip and knee flexion and extension. The sensory system included goniometers at knee and hip joints, force-sensing resistors built in the shoe insoles, and digital accelerometers at the hips. A rule-based control algorithm was generated following a two-step procedure: (1) simulation and (2) machine learning as described in earlier studies (IEEE Trans Rehab Eng, TRE-7 (1999) 69). The paraplegic subject walked faster, and with less physiological effort, when automatic control was applied as compared to hand-control. This case study, as well as a previous one for assisting grasping (The design and testing of a new programmable electronic stimulator. N. Fisekovic, MS thesis. University of Belgrade, Belgrade, 2000) indicate that the novel control unit is effectively applicable to FES systems.
25 ns software correlator for photon and fluorescence correlation spectroscopy
NASA Astrophysics Data System (ADS)
Magatti, Davide; Ferri, Fabio
2003-02-01
A 25 ns time resolution, multi-tau software correlator developed in LABVIEW based on the use of a standard photon counting unit, a fast timer/counter board (6602-PCI National Instrument) and a personal computer (PC) (1.5 GHz Pentium 4) is presented and quantitatively discussed. The correlator works by processing the stream of incoming data in parallel according to two different algorithms: For large lag times (τ⩾100 μs), a classical time-mode (TM) scheme, based on the measure of the number of pulses per time interval, is used; differently, for τ⩽100 μs a photon-mode (PM) scheme is adopted and the time sequence of the arrival times of the photon pulses is measured. By combining the two methods, we developed a system capable of working out correlation functions on line, in full real time for the TM correlator and partially in batch processing for the PM correlator. For the latter one, the duty cycle depends on the count rate of the incoming pulses, being ˜100% for count rates ⩽3×104 Hz, ˜15% at 105 Hz, and ˜1% at 106 Hz. For limitations imposed by the fairly small first-in, first-out (FIFO) buffer available on the counter board, the maximum count rate permissible for a proper functioning of the PM correlator is limited to ˜105 Hz. However, this limit can be removed by using a board with a deeper FIFO. Similarly, the 25 ns time resolution is only limited by maximum clock frequency available on the 6602-PCI and can be easily improved by using a faster clock. When tested on dilute solutions of calibrated latex spheres, the overall performances of the correlator appear to be comparable with those of commercial hardware correlators, but with several nontrivial advantages related to its flexibility, low cost, and easy adaptability to future developments of PC and data acquisition technology.
Educating adult females for leadership roles in an informal science program for girls
NASA Astrophysics Data System (ADS)
McCreedy, Dale
The purpose of this study is to gain an understanding of and an evidentiary warrant for, how a community of practice focused on informal science learning, can engage and promote active participation that offers adult female members and the community opportunities for legitimacy and transformation. This study is a qualitative, ethnographic research study that documents how adult female volunteers, historically inexperienced and/or excluded from traditional practices of science, come to engage in science activities through an informal, community-based context that helps them to appreciate science connections in their lives that are ultimately empowering and agentic. I begin to understand the ways in which such informal contexts, often thought to be marginal to dominant educational beliefs and practices, can offer adults outside of the field of science, education, or both, an entree into science learning and teaching that facilitate female's participation in legitimate and empowering ways. Using descriptive analyses, I first identify the characteristics of peripheral and active program participants. Through phenomenological analyses, I then develop an understanding of participation in an informal science program by focusing on three adult female members' unique trajectories of participation leading to core member status. Each draws on different aspects of the program that they find most salient, illustrating how different elements can serve as motivators for participation, and support continuation along the trajectory of participation reflecting personal and political agency. Through a purposeful ethnographic case-study analysis, I then explore one core member's transformation, evidenced by her developing identities as someone who enjoys science, engages in science activities, and, enacts a role as community old timer and door opener to science learning. This study: (1) contributes to the limited knowledge base in fields of informal learning, science education, and feminist research; (2) provides data that lead to assertions about the impact of NSP participation; and (3) takes advantage of a unique context in which to study adults and the interaction of gender, science, and informal learning.
A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi
2010-04-01
The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.
Putting Theory to the Test: Which Regulatory Mechanisms Can Drive Realistic Growth of a Root?
De Vos, Dirk; Vissenberg, Kris; Broeckhove, Jan; Beemster, Gerrit T. S.
2014-01-01
In recent years there has been a strong development of computational approaches to mechanistically understand organ growth regulation in plants. In this study, simulation methods were used to explore which regulatory mechanisms can lead to realistic output at the cell and whole organ scale and which other possibilities must be discarded as they result in cellular patterns and kinematic characteristics that are not consistent with experimental observations for the Arabidopsis thaliana primary root. To aid in this analysis, a ‘Uniform Longitudinal Strain Rule’ (ULSR) was formulated as a necessary condition for stable, unidirectional, symplastic growth. Our simulations indicate that symplastic structures are robust to differences in longitudinal strain rates along the growth axis only if these differences are small and short-lived. Whereas simple cell-autonomous regulatory rules based on counters and timers can produce stable growth, it was found that steady developmental zones and smooth transitions in cell lengths are not feasible. By introducing spatial cues into growth regulation, those inadequacies could be avoided and experimental data could be faithfully reproduced. Nevertheless, a root growth model based on previous polar auxin-transport mechanisms violates the proposed ULSR due to the presence of lateral gradients. Models with layer-specific regulation or layer-driven growth offer potential solutions. Alternatively, a model representing the known cross-talk between auxin, as the cell proliferation promoting factor, and cytokinin, as the cell differentiation promoting factor, predicts the effect of hormone-perturbations on meristem size. By down-regulating PIN-mediated transport through the transcription factor SHY2, cytokinin effectively flattens the lateral auxin gradient, at the basal boundary of the division zone, (thereby imposing the ULSR) to signal the exit of proliferation and start of elongation. This model exploration underlines the value of generating virtual root growth kinematics to dissect and understand the mechanisms controlling this biological system. PMID:25358093
Putting theory to the test: which regulatory mechanisms can drive realistic growth of a root?
De Vos, Dirk; Vissenberg, Kris; Broeckhove, Jan; Beemster, Gerrit T S
2014-10-01
In recent years there has been a strong development of computational approaches to mechanistically understand organ growth regulation in plants. In this study, simulation methods were used to explore which regulatory mechanisms can lead to realistic output at the cell and whole organ scale and which other possibilities must be discarded as they result in cellular patterns and kinematic characteristics that are not consistent with experimental observations for the Arabidopsis thaliana primary root. To aid in this analysis, a 'Uniform Longitudinal Strain Rule' (ULSR) was formulated as a necessary condition for stable, unidirectional, symplastic growth. Our simulations indicate that symplastic structures are robust to differences in longitudinal strain rates along the growth axis only if these differences are small and short-lived. Whereas simple cell-autonomous regulatory rules based on counters and timers can produce stable growth, it was found that steady developmental zones and smooth transitions in cell lengths are not feasible. By introducing spatial cues into growth regulation, those inadequacies could be avoided and experimental data could be faithfully reproduced. Nevertheless, a root growth model based on previous polar auxin-transport mechanisms violates the proposed ULSR due to the presence of lateral gradients. Models with layer-specific regulation or layer-driven growth offer potential solutions. Alternatively, a model representing the known cross-talk between auxin, as the cell proliferation promoting factor, and cytokinin, as the cell differentiation promoting factor, predicts the effect of hormone-perturbations on meristem size. By down-regulating PIN-mediated transport through the transcription factor SHY2, cytokinin effectively flattens the lateral auxin gradient, at the basal boundary of the division zone, (thereby imposing the ULSR) to signal the exit of proliferation and start of elongation. This model exploration underlines the value of generating virtual root growth kinematics to dissect and understand the mechanisms controlling this biological system.
NASA Astrophysics Data System (ADS)
Weigand, R.
Two new processor devices have been developed for the use on board of spacecrafts. An 8-bit 8032-microcontroller targets typical controlling applications in instruments and sub-systems, or could be used as a main processor on small satellites, whereas the LEON 32-bit SPARC processor can be used for high performance controlling and data processing tasks. The ADV80S32 is fully compliant to the Intel 80x1 architecture and instruction set, extended by additional peripherals, 512 bytes on-chip RAM and a bootstrap PROM, which allows downloading the application software using the CCSDS PacketWire pro- tocol. The memory controller provides a de-multiplexed address/data bus, and allows to access up to 16 MB data and 8 MB program RAM. The peripherals have been de- signed for the specific needs of a spacecraft, such as serial interfaces compatible to RS232, PacketWire and TTC-B-01, counters/timers for extended duration and a CRC calculation unit accelerating the CCSDS TM/TC protocol. The 0.5 um Atmel manu- facturing technology (MG2RT) provides latch-up and total dose immunity; SEU fault immunity is implemented by using SEU hardened Flip-Flops and EDAC protection of internal and external memories. The maximum clock frequency of 20 MHz allows a processing power of 3 MIPS. Engineering samples are available. For SW develop- ment, various SW packages for the 8051 architecture are on the market. The LEON processor implements a 32-bit SPARC V8 architecture, including all the multiply and divide instructions, complemented by a floating-point unit (FPU). It includes several standard peripherals, such as timers/watchdog, interrupt controller, UARTs, parallel I/Os and a memory controller, allowing to use 8, 16 and 32 bit PROM, SRAM or memory mapped I/O. With on-chip separate instruction and data caches, almost one instruction per clock cycle can be reached in some applications. A 33-MHz 32-bit PCI master/target interface and a PCI arbiter allow operating the device in a plug-in card (for SW development on PC etc.), or to consider using it as a PCI master controller in an on-board system. Advanced SEU fault tolerance is in- troduced by design, using triple modular redundancy (TMR) flip-flops for all registers and EDAC protection for all memories. The device will be manufactured in a radia- tion hard Atmel 0.25 um technology, targeting 100 MHz processor clock frequency. The non fault-tolerant LEON processor VHDL model is available as free source code, and the SPARC architecture is a well-known industry standard. Therefore, know-how, software tools and operating systems are widely available.
Real Time Linux - The RTOS for Astronomy?
NASA Astrophysics Data System (ADS)
Daly, P. N.
The BoF was attended by about 30 participants and a free CD of real time Linux-based upon RedHat 5.2-was available. There was a detailed presentation on the nature of real time Linux and the variants for hard real time: New Mexico Tech's RTL and DIAPM's RTAI. Comparison tables between standard Linux and real time Linux responses to time interval generation and interrupt response latency were presented (see elsewhere in these proceedings). The present recommendations are to use RTL for UP machines running the 2.0.x kernels and RTAI for SMP machines running the 2.2.x kernel. Support, both academically and commercially, is available. Some known limitations were presented and the solutions reported e.g., debugging and hardware support. The features of RTAI (scheduler, fifos, shared memory, semaphores, message queues and RPCs) were described. Typical performance statistics were presented: Pentium-based oneshot tasks running > 30kHz, 486-based oneshot tasks running at ~ 10 kHz, periodic timer tasks running in excess of 90 kHz with average zero jitter peaking to ~ 13 mus (UP) and ~ 30 mus (SMP). Some detail on kernel module programming, including coding examples, were presented showing a typical data acquisition system generating simulated (random) data writing to a shared memory buffer and a fifo buffer to communicate between real time Linux and user space. All coding examples were complete and tested under RTAI v0.6 and the 2.2.12 kernel. Finally, arguments were raised in support of real time Linux: it's open source, free under GPL, enables rapid prototyping, has good support and the ability to have a fully functioning workstation capable of co-existing hard real time performance. The counter weight-the negatives-of lack of platforms (x86 and PowerPC only at present), lack of board support, promiscuous root access and the danger of ignorance of real time programming issues were also discussed. See ftp://orion.tuc.noao.edu/pub/pnd/rtlbof.tgz for the StarOffice overheads for this presentation.
2012-01-01
Background Use of diagnostics in integrated community case management (iCCM) of fever is recognized as an important step in improving rational use of drugs and quality of care for febrile under-five children. This study assessed household access, acceptability and utilization of community health workers (CHWs) trained and provided with malaria rapid diagnostic tests (RDTs) and respiratory rate timers (RRTs) to practice iCCM. Methods A total of 423 households with under-five children were enrolled into the study in Iganga district, Uganda. Households were selected from seven villages in Namungalwe sub-county using probability proportionate to size sampling. A semi-structured questionnaire was administered to caregivers in selected households. Data were entered into Epidata statistical software, and analysed using SPSS Statistics 17.0, and STATA version 10. Results Most (86%, 365/423) households resided within a kilometre of a CHW’s home, compared to 26% (111/423) residing within 1 km of a health facility (p < 0.001). The median walking time by caregivers to a CHW was 10 minutes (IQR 5–20). The first option for care for febrile children in the month preceding the survey was CHWs (40%, 242/601), followed by drug shops (33%, 196/601). Fifty-seven percent (243/423) of caregivers took their febrile children to a CHW at least once in the three month period preceding the survey. Households located 1–3 km from a health facility were 72% (AOR 1.72; 95% CI 1.11–2.68) more likely to utilize CHW services compared to households within 1 km of a health facility. Households located 1–3 km from a CHW were 81% (AOR 0.19; 95% CI 0.10–0.36) less likely to utilize CHW services compared to those households residing within 1 km of a CHW. A majority (79%, 336/423) of respondents thought CHWs services were better with RDTs, and 89% (375/423) approved CHWs’ continued use of RDTs. Eighty-six percent (209/243) of respondents who visited a CHW thought RRTs were useful. Conclusion ICCM with diagnostics is acceptable, increases access, and is the first choice for caregivers of febrile children. More than half of caregivers of febrile children utilized CHW services over a three-month period. However, one-third of caregivers used drug shops in spite of the presence of CHWs. PMID:22521034
Improving Abnormality Detection on Chest Radiography Using Game-Like Reinforcement Mechanics.
Chen, Po-Hao; Roth, Howard; Galperin-Aizenberg, Maya; Ruutiainen, Alexander T; Gefter, Warren; Cook, Tessa S
2017-11-01
Despite their increasing prevalence, online textbooks, question banks, and digital references focus primarily on explicit knowledge. Implicit skills such as abnormality detection require repeated practice on clinical service and have few digital substitutes. Using mechanics traditionally deployed in video games such as clearly defined goals, rapid-fire levels, and narrow time constraints may be an effective way to teach implicit skills. We created a freely available, online module to evaluate the ability of individuals to differentiate between normal and abnormal chest radiographs by implementing mechanics, including instantaneous feedback, rapid-fire cases, and 15-second timers. Volunteer subjects completed the modules and were separated based on formal experience with chest radiography. Performance between training and testing sets were measured for each group, and a survey was administered after each session. The module contained 74 cases and took approximately 20 minutes to complete. Thirty-two cases were normal radiographs and 56 cases were abnormal. Of the 60 volunteers recruited, 25 were "never trained" and 35 were "previously trained." "Never trained" users scored 21.9 out of 37 during training and 24.0 out of 37 during testing (59.1% vs 64.9%, P value <.001). "Previously trained" users scored 28.0 out of 37 during training and 28.3 out of 37 during testing phases (75.6% vs 76.4%, P value = .56). Survey results showed that 87% of all subjects agreed the module is an efficient way of learning, and 83% agreed the rapid-fire module is valuable for medical students. A gamified online module may improve the abnormality detection rates of novice interpreters of chest radiography, although experienced interpreters are less likely to derive similar benefits. Users reviewed the educational module favorably. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
C2-Related Incidents Reported by UAS Pilots
NASA Technical Reports Server (NTRS)
Hobbs, Alan; Cardoza, Colleen; Null, Cynthia
2016-01-01
It has been estimated that aviation accidents are typically preceded by numerous minor incidents arising from the same causal factors that ultimately produced the accident. Accident databases provide in-depth information on a relatively small number of occurrences, however incident databases have the potential to provide insights into the human factors of Remotely Piloted Aircraft System (RPAS) operations based on a larger volume of less-detailed reports. Currently, there is a lack of incident data dealing with the human factors of unmanned aircraft systems. An exploratory study is being conducted to examine the feasibility of collecting voluntary critical incident reports from RPAS pilots. Twenty-three experienced RPAS pilots volunteered to participate in focus groups in which they described critical incidents from their own experience. Participants were asked to recall (1) incidents that revealed a system flaw, or (2) highlighted a case where the human operator contributed to system resilience or mission success. Participants were asked to only report incidents that could be included in a public document. During each focus group session, a note taker produced a de-identified written record of the incident narratives. At the end of the session, participants reviewed each written incident report, and made edits and corrections as necessary. The incidents were later analyzed to identify contributing factors, with a focus on design issues that either hindered or assisted the pilot during the events. A total of 90 incidents were reported. This presentation focuses on incidents that involved the management of the command and control (C2) link. The identified issues include loss of link, interference from undesired transmissions, voice latency, accidental control transfer, and the use of the lost link timer, or lost link OK features.
275 C Downhole Microcomputer System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chris Hutchens; Hooi Miin Soo
2008-08-31
An HC11 controller IC and along with serial SRAM and ROM support ICs chip set were developed to support a data acquisition and control for extreme temperature/harsh environment conditions greater than 275 C. The 68HC11 microprocessor is widely used in well logging tools for control, data acquisition, and signal processing applications and was the logical choice for a downhole controller. This extreme temperature version of the 68HC11 enables new high temperature designs and additionally allows 68HC11-based well logging tools and MWD tools to be upgraded for high temperature operation in deep gas reservoirs, The microcomputer chip consists of the microprocessormore » ALU, a small boot ROM, 4 kbyte data RAM, counter/timer unit, serial peripheral interface (SPI), asynchronous serial interface (SCI), and the A, B, C, and D parallel ports. The chip is code compatible with the single chip mode commercial 68HC11 except for the absence of the analog to digital converter system. To avoid mask programmed internal ROM, a boot program is used to load the microcomputer program from an external mask SPI ROM. A SPI RAM IC completes the chip set and allows data RAM to be added in 4 kbyte increments. The HC11 controller IC chip set is implemented in the Peregrine Semiconductor 0.5 micron Silicon-on-Sapphire (SOS) process using a custom high temperature cell library developed at Oklahoma State University. Yield data is presented for all, the HC11, SPI-RAM and ROM. The lessons learned in this project were extended to the successful development of two high temperature versions of the LEON3 and a companion 8 Kbyte SRAM, a 200 C version for the Navy and a 275 C version for the gas industry.« less
A dynamic kernel modifier for linux
DOE Office of Scientific and Technical Information (OSTI.GOV)
Minnich, R. G.
2002-09-03
Dynamic Kernel Modifier, or DKM, is a kernel module for Linux that allows user-mode programs to modify the execution of functions in the kernel without recompiling or modifying the kernel source in any way. Functions may be traced, either function entry only or function entry and exit; nullified; or replaced with some other function. For the tracing case, function execution results in the activation of a watchpoint. When the watchpoint is activated, the address of the function is logged in a FIFO buffer that is readable by external applications. The watchpoints are time-stamped with the resolution of the processor highmore » resolution timers, which on most modem processors are accurate to a single processor tick. DKM is very similar to earlier systems such as the SunOS trace device or Linux TT. Unlike these two systems, and other similar systems, DKM requires no kernel modifications. DKM allows users to do initial probing of the kernel to look for performance problems, or even to resolve potential problems by turning functions off or replacing them. DKM watchpoints are not without cost: it takes about 200 nanoseconds to make a log entry on an 800 Mhz Pentium-Ill. The overhead numbers are actually competitive with other hardware-based trace systems, although it has less 'Los Alamos National Laboratory is operated by the University of California for the National Nuclear Security Administration of the United States Department of Energy under contract W-7405-ENG-36. accuracy than an In-Circuit Emulator such as the American Arium. Once the user has zeroed in on a problem, other mechanisms with a higher degree of accuracy can be used.« less
My personal experiences at the BEST Medical Center: A day in the clinic-the morning.
Cohen, Philip R; Kurzrock, Razelle
2016-01-01
Dr. Ida Lystic is a gastroenterologist who trained at the OTHER (Owen T. Henry and Eugene Rutherford) Medical Center, after having completed her MD degree at the prestigious Harvey Medical School (recently renamed the Harvey Provider School). She accepted a faculty position at the BEST (Byron Edwards and Samuel Thompson) Medical Center. Dr. Lystic shares her experiences on a typical morning in gastroenterology clinic. Although her clinic start date was delayed by 2 months after becoming sick following a mandatory flu shot and having to complete more than 70 hours of compliance training modules, she is now familiar with the BEST system. Clinic scheduling priorities include ensuring that the staff can eat lunch together and depart at 5:00 pm. It is a continual challenge to find time to complete the electronic medical record after BEST changed from the SIMPLE (Succinct Input Making Patients Lives Electronic) system to LEGEND (referred to as Lengthy and Excessively Graded Evaluation and Nomenclature for Diagnosis by her colleagues). To maintain clinic punctuality, a compliance spreadsheet is e-mailed monthly to the Wait Time Committee. Their most recent corrective action plan for tardy physicians included placing egg timers on the doors and having nurses interrupt visits that exceed the allotted time. Administrative decisions have resulted in downsizing personnel. Patients are required to schedule their own tests and procedures and follow-up appointments-causing low patient satisfaction scores; however, the money saved lead to a large year-end bonus for the vice president of BEST Efficiency, who holds "providers" accountable for the poor patient experience. Although Dr. Ida Lystic and the gastroenterology clinic at "the BEST Medical Center" are creations of the authors' imagination, the majority of the anecdotes are based on actual events. Copyright © 2016 Elsevier Inc. All rights reserved.
Regenerable biocide delivery unit
NASA Technical Reports Server (NTRS)
Sauer, Richard L. (Inventor); Colombo, Gerald V. (Inventor); Jolly, Clifford D. (Inventor)
1993-01-01
A method and apparatus are disclosed for maintaining continuous, long-term microbial control in the water supply for potable, hygiene, and experimental water for space activities, as well as treatment of water supplies on Earth. The water purification is accomplished by introduction of molecular iodine into the water supply to impart a desired iodine residual. The water is passed through an iodinated anion exchange resin bed. The iodine is bound as I-(sub n) at the anion exchange sites and releases I(sub 2) into the water stream flowing through the bed. The concentration of I(sub 2) in the flowing water gradually decreases and, in the prior art, the ion-exchange bed has had to be replaced. In a preferred embodiment, a bed of iodine crystals is provided with connections for flowing water therethrough to produce a concentrated (substantially saturated) aqueous iodine solution which is passed through the iodinated resin bed to recharge the bed with bound iodine. The bed of iodine crystals is connected in parallel with the iodinated resin bed and is activated periodically (e.g., by timer, by measured flow of water, or by iodine residual level) to recharge the bed. Novelty resides in the capability of inexpensively and repeatedly regenerating the ion-exchange bed in situ.
Fernandes, Ana Clara; Uytterhoeven, Valerie; Kuenen, Sabine; Wang, Yu-Chun; Slabbaert, Jan R; Swerts, Jef; Kasprowicz, Jaroslaw; Aerts, Stein; Verstreken, Patrik
2014-11-24
Synaptic demise and accumulation of dysfunctional proteins are thought of as common features in neurodegeneration. However, the mechanisms by which synaptic proteins turn over remain elusive. In this paper, we study Drosophila melanogaster lacking active TBC1D24/Skywalker (Sky), a protein that in humans causes severe neurodegeneration, epilepsy, and DOOR (deafness, onychdystrophy, osteodystrophy, and mental retardation) syndrome, and identify endosome-to-lysosome trafficking as a mechanism for degradation of synaptic vesicle-associated proteins. In fly sky mutants, synaptic vesicles traveled excessively to endosomes. Using chimeric fluorescent timers, we show that synaptic vesicle-associated proteins were younger on average, suggesting that older proteins are more efficiently degraded. Using a genetic screen, we find that reducing endosomal-to-lysosomal trafficking, controlled by the homotypic fusion and vacuole protein sorting (HOPS) complex, rescued the neurotransmission and neurodegeneration defects in sky mutants. Consistently, synaptic vesicle proteins were older in HOPS complex mutants, and these mutants also showed reduced neurotransmission. Our findings define a mechanism in which synaptic transmission is facilitated by efficient protein turnover at lysosomes and identify a potential strategy to suppress defects arising from TBC1D24 mutations in humans. © 2014 Fernandes et al.
George, Asha; Young, Mark; Nefdt, Rory; Basu, Roshni; Sylla, Mariame; Clarysse, Guy; Bannicq, Marika Yip; de Sousa, Alexandra; Binkin, Nancy; Diaz, Theresa
2012-11-01
We describe community health workers (CHWs) in government community case management (CCM) programs for child survival across sub-Saharan Africa. In sub-Saharan Africa, 91% of 44 United Nations Children's Fund (UNICEF) offices responded to a cross-sectional survey in 2010. Frequencies describe CHW profiles and activities in government CCM programs (N = 29). Although a few programs paid CHWs a salary or conversely, rewarded CHWs purely on a non-financial basis, most programs combined financial and non-financial incentives and had training for 1 week. Not all programs allowed CHWs to provide zinc, use timers, dispense antibiotics, or use rapid diagnostic tests. Many CHWs undertake health promotion, but fewer CHWs provide soap, water treatment products, indoor residual spraying, or ready-to-use therapeutic foods. For newborn care, very few promote kangaroo care, and they do not provide antibiotics or resuscitation. Even if CHWs are as varied as the health systems in which they work, more work must be done in terms of the design and implementation of the CHW programs for them to realize their potential.
Automatic calibration and control system for a combined oxygen and combustibles analyzer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woolbert, G.D.; Jewett, S.Y.; Robertson, J.W. Jr.
1989-08-01
This patent describes an automatic, periodically calibrating system for continuous output of calibrated signals from a combined oxygen and combustibles analyzer. It comprises: a combined oxygen and combustibles analyzer for sensing a level of oxygen and a level of combustibles in a volatile atmosphere and for producing a first sample signal indicative of the oxygen level and a second sample signal indicative of the combustibles level; means for introducing zero and span calibration test gases into the analyzer; means for periodically calibrating the analyzer. This including: a data control unit; a timer unit; a mechanical unit, means for calculating zeromore » and span values for oxygen and combustibles, means for comparing the calculated zero and span values for oxygen and combustibles to the preset alarm limits for oxygen and combustibles, means for activating an operator alarm, means for calculating oxygen and combustibles drift adjustments, a memory unit; and means for applying the oxygen and combustibles drift adjustments concurrently to the first and second sample signals, according to predetermined mathematical relationship, to obtain calibrated output signals indicative of the oxygen and combustibles level in the volatile atmosphere.« less
Metronome LKM: An open source virtual keyboard driver to measure experiment software latencies.
Garaizar, Pablo; Vadillo, Miguel A
2017-10-01
Experiment software is often used to measure reaction times gathered with keyboards or other input devices. In previous studies, the accuracy and precision of time stamps has been assessed through several means: (a) generating accurate square wave signals from an external device connected to the parallel port of the computer running the experiment software, (b) triggering the typematic repeat feature of some keyboards to get an evenly separated series of keypress events, or (c) using a solenoid handled by a microcontroller to press the input device (keyboard, mouse button, touch screen) that will be used in the experimental setup. Despite the advantages of these approaches in some contexts, none of them can isolate the measurement error caused by the experiment software itself. Metronome LKM provides a virtual keyboard to assess an experiment's software. Using this open source driver, researchers can generate keypress events using high-resolution timers and compare the time stamps collected by the experiment software with those gathered by Metronome LKM (with nanosecond resolution). Our software is highly configurable (in terms of keys pressed, intervals, SysRq activation) and runs on 2.6-4.8 Linux kernels.
Application Reuse Library for Software, Requirements, and Guidelines
NASA Technical Reports Server (NTRS)
Malin, Jane T.; Thronesbery, Carroll
1994-01-01
Better designs are needed for expert systems and other operations automation software, for more reliable, usable and effective human support. A prototype computer-aided Application Reuse Library shows feasibility of supporting concurrent development and improvement of advanced software by users, analysts, software developers, and human-computer interaction experts. Such a library expedites development of quality software, by providing working, documented examples, which support understanding, modification and reuse of requirements as well as code. It explicitly documents and implicitly embodies design guidelines, standards and conventions. The Application Reuse Library provides application modules with Demo-and-Tester elements. Developers and users can evaluate applicability of a library module and test modifications, by running it interactively. Sub-modules provide application code and displays and controls. The library supports software modification and reuse, by providing alternative versions of application and display functionality. Information about human support and display requirements is provided, so that modifications will conform to guidelines. The library supports entry of new application modules from developers throughout an organization. Example library modules include a timer, some buttons and special fonts, and a real-time data interface program. The library prototype is implemented in the object-oriented G2 environment for developing real-time expert systems.
Marine chronometry in the Neuchatel mountains (Switzerland)
NASA Astrophysics Data System (ADS)
Fallet, Estelle
The history and evolution of the Swiss marine chronometer industry are summarized. From the 18th century onwards, Neuchatel watchmakers strove to develop precision horology. First J. F. Houriet and later S. Mairet, L. Richard, W. Dubois and H. Grandjean introduced the marine chronometer in the Neuchatel mountains. Precision having become a necessity for the industry, they helped achive this by means of a complex system for the distribution and maintenance of exact time, which allowed optimal adjustment. These men of vision called for the building of a cantonal observatory and strove to have their art practiced in modern watchmaking schools. Under the guidance first of Ulysse and then of Paul David Nardin, the manufacture of marine chronometers began in Le Locle in 1876. In La Chaux-de-Fonds at the beginning of the 20th century, Paul Ditisheim built a number of improved marine, ship and pocket chronometers. Together with scientists and watchmakers, the chronometer makers perfected the regulating parts of the timekeepers and solved the problems of adjustment caused by the various external influences. The manufacturers, the watchmakers at their branches, the timers and the Neuchatel business all contributed to strengthening the position of the products of their region in the world market.
NASA Technical Reports Server (NTRS)
Ludwig, Kimberly; Mackin, Michael; Wright, Theodore
1991-01-01
The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.
Shiozaki, Arihiro; Yoneda, Satoshi; Nakabayashi, Masao; Takeda, Yoshiharu; Takeda, Satoru; Sugimura, Motoi; Yoshida, Koyo; Tajima, Atsushi; Manabe, Mami; Akagi, Kozo; Nakagawa, Shoko; Tada, Katsuhiko; Imafuku, Noriaki; Ogawa, Masanobu; Mizunoe, Tomoya; Kanayama, Naohiro; Itoh, Hiroaki; Minoura, Shigeki; Ogino, Mitsuharu; Saito, Shigeru
2014-01-01
To examine the relationship between preterm birth and socioeconomic factors, past history, cervical length, cervical interleukin-8, bacterial vaginosis, underlying diseases, use of medication, employment status, sex of the fetus and multiple pregnancy. In a multicenter, prospective, observational study, 1810 Japanese women registering their future delivery were enrolled at 8⁺⁰ to 12⁺⁶ weeks of gestation. Data on cervical length and delivery were obtained from 1365 pregnant women. Multivariate logistic regression analysis was performed. Short cervical length, steroid use, multiple pregnancy and male fetus were risk factors for preterm birth before 34 weeks of gestation. Multiple pregnancy, low educational level, short cervical length and part-timer were risk factors for preterm birth before 37 weeks of gestation. Multiple pregnancy and cervical shortening at 20-24 weeks of gestation was a stronger risk factor for preterm birth. Any pregnant woman being part-time employee or low educational level, having a male fetus and requiring steroid treatment should be watched for the development of preterm birth. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Evidence for an alternation strategy in time-place learning.
Pizzo, Matthew J; Crystal, Jonathon D
2004-11-30
Many different conclusions concerning what type of mechanism rats use to solve a daily time-place task have emerged in the literature. The purpose of this study was to test three competing explanations of time-place discrimination. Rats (n = 10) were tested twice daily in a T-maze, separated by approximately 7 h. Food was available at one location in the morning and another location in the afternoon. After the rats learned to visit each location at the appropriate time, tests were omitted to evaluate whether the rats were utilizing time-of-day (i.e., a circadian oscillator) or an alternation strategy (i.e., visiting a correct location is a cue to visit the next location). Performance on this test was significantly lower than chance, ruling out the use of time-of-day. A phase advance of the light cycle was conducted to test the alternation strategy and timing with respect to the light cycle (i.e., an interval timer). There was no difference between probe and baseline performance. These results suggest that the rats used an alternation strategy to meet the temporal and spatial contingencies in the time-place task.
A microcomputer system for on-line study of atrioventricular node accommodation.
Jenkins, J R; Clemo, H F; Belardinelli, L
1987-11-01
An automated on-line programmable stimulator and interval measurement system was developed to study atrioventricular node (AVN) accommodation. This dedicated microcomputer system measures and stores the stimulus-to-His bundle (S-H) interval from His bundle electrogram (HBE) recordings. Interval measurements for each beat are accurate to within 500 microsecond. This user-controlled system has been used to stimulate at any rate up to 6.5 Hz and to measure intervals up to 125 ms in isolated perfused guinea pig hearts. A built-in timer-reset mechanism prevents failure of the system in the absence of a His potential (i.e., 2:1 AV block). It may be modified for use in clinical studies or other experimental systems and has the ability to measure other physiological intervals. The system provides the precision in pacing and accuracy in the measurement of AVN conduction time that is necessary for meaningful analysis of AVN accommodation and has the simplicity of design and use that is not available in previously described systems. Furthermore, this computer system can be used not only in studies involving AV conduction, but also in any setting where programmed stimulation and interval measurement and recording need to be performed simultaneously.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menczer, L.F.
A study of 41 x-ray machines in 31 private dental offices in the Greater Hartford area showed that every x-ray unit permitted gonadal radiation exposure, ranging from 8 to 88 Mr. With few exceptions, the timing devices on all units were inaccurate by as much as 1/2 sec. About 20% of the units needed some mechanical repair, and 7 units demonstrated excessive lealcage radiation. In 50% of the dental offices, x-ray film was purchased on a cost basis rather than on a quality basis. The average length of exposure per film ranged from 3/4 to 4 sec; the usual exposuremore » was from 12/4 to 21/4 sec. No x-ray unit was on an independent electrical supply. Timer cords were usually no more than 5 ft long and did not permit the operator to get into a more protected position when exposing dental roentgenograms. In several instances the x-ray unit was close to business offices or to treatment rooms. The attitude of the average dentist in the study toward the potential hazards of x-ray radiation to his office personnel and patients was poor or showed lack of concern. Recommendations for reduction of gonadal radiation exposure are given. (TCO)« less
Wu, Lai Man Natalie; Wang, Jincheng; Conidi, Andrea; Zhao, Chuntao; Wang, Haibo; Ford, Zachary; Zhang, Liguo; Zweier, Christiane; Ayee, Brian G; Maurel, Patrice; Zwijsen, An; Chan, Jonah R; Jankowski, Michael P; Huylebroeck, Danny; Lu, Q Richard
2016-08-01
The mechanisms that coordinate and balance a complex network of opposing regulators to control Schwann cell (SC) differentiation remain elusive. Here we demonstrate that zinc-finger E-box-binding homeobox 2 (Zeb2, also called Sip1) transcription factor is a critical intrinsic timer that controls the onset of SC differentiation by recruiting histone deacetylases HDAC 1 and 2 (HDAC1/2) and nucleosome remodeling and deacetylase complex (NuRD) co-repressor complexes in mice. Zeb2 deletion arrests SCs at an undifferentiated state during peripheral nerve development and inhibits remyelination after injury. Zeb2 antagonizes inhibitory effectors including Notch and Sox2. Importantly, genome-wide transcriptome analysis reveals a Zeb2 target gene encoding the Notch effector Hey2 as a potent inhibitor for Schwann cell differentiation. Strikingly, a genetic Zeb2 variant associated with Mowat-Wilson syndrome disrupts the interaction with HDAC1/2-NuRD and abolishes Zeb2 activity for SC differentiation. Therefore, Zeb2 controls SC maturation by recruiting HDAC1/2-NuRD complexes and inhibiting a Notch-Hey2 signaling axis, pointing to the critical role of HDAC1/2-NuRD activity in peripheral neuropathies caused by ZEB2 mutations.