Abtahi-Naeini, Bahareh; Faghihi, Gita; Shahmoradi, Zabihollah; Saffaei, Ali
2018-01-07
Polydimethylsiloxane (PDMS), also called liquid silicone, belongs to a group of polymeric compounds that are commonly referred to as silicones. These filling agents have been used as injectable filler for soft tissue augmentation. There are limited experiences about management of the severe complications related to filler migration associated with PDMS injection. We present a 35-year-old female with severe erythema, edema over her cheeks and neck, and multiple irregularities following cosmetic lip augmentation with PDMS. Further studies are required for management of this complicated case of PDMS injection. © 2018 Wiley Periodicals, Inc.
Ultrasound detection and identification of cosmetic fillers in the skin.
Wortsman, X; Wortsman, J; Orlandi, C; Cardenas, G; Sazunic, I; Jemec, G B E
2012-03-01
While the incidence of cosmetic filler injections is rising world-wide, neither exact details of the procedure nor the agent used are always reported or remembered by the patients. Thus, although complications are reportedly rare, availability of a precise diagnostic tool to detect cutaneous filler deposits could help clarify the association between the procedure and the underlying pathology. The aim of this study was to evaluate cutaneous sonography in the detection and identification of cosmetic fillers deposits and, describe dermatological abnormalities found associated with the presence of those agents. We used ultrasound in a porcine skin model to determine the sonographic characteristics of commonly available filler agents, and subsequently applied the analysis to detect and identify cosmetic fillers among patients referred for skin disorders. Fillers are recognizable on ultrasound and generate different patterns of echogenicity and posterior acoustic artefacts. Cosmetic fillers were identified in 118 dermatological patients; most commonly hyaluronic acid among degradable agents and silicone oil among non-degradable. Fillers deposits were loosely scattered throughout the subcutaneous tissue, with occasional infiltration of local muscles and loco-regional lymph nodes. Accompanying dermatopathies were represented by highly localized inflammatory processes unresponsive to conventional treatment, morphea-like reactions, necrosis of fatty tissue and epidermal cysts; in the case of non-degradable agents, the associated dermatopathies were transient, resolving upon disappearance of the filler. Cosmetic filler agents may be detected and identified during routine ultrasound of dermatological lesions; the latter appear to be pathologically related to the cosmetic procedure. © 2011 The Authors. Journal of the European Academy of Dermatology and Venereology © 2011 European Academy of Dermatology and Venereology.
Zerbinati, Nicola; D'Este, Edoardo; Parodi, Pier Camillo; Calligaro, Alberto
2017-07-01
This study uses light and electron microscopes to gain a better knowledge of the interactions of calcium hydroxylapatite filler with the connective tissue of the skin and the modifications of the human deep dermis, after 2 months of treatment. Some morphological evidences of this observational study of filler treated tissue support-specific mechanism involved in the structural modifications of both filler microspherules and cells of the connective tissue. They demonstrate the absence of any immunological reaction and show that the used filler is modified very slowly over time by the action of cells of the connective tissue closely related to the filler without any activity of phagocytosis. Furthermore, associated with the modifications of the filler, evidences of stimulatory effects on dermal fibroblasts are reported.
The Hyaluronic Acid Fillers: Current Understanding of the Tissue Device Interface.
Greene, Jacqueline J; Sidle, Douglas M
2015-11-01
The article is a detailed update regarding cosmetic injectable fillers, specifically focusing on hyaluronic acid fillers. Hyaluronic acid-injectable fillers are used extensively for soft tissue volumizing and contouring. Many different hyaluronic acid-injectable fillers are available on the market and differ in terms of hyaluronic acid concentration, particle size, cross-linking density, requisite needle size, duration, stiffness, hydration, presence of lidocaine, type of cross-linking technology, and cost. Hyaluronic acid is a natural component of many soft tissues, is identical across species minimizing immunogenicity has been linked to wound healing and skin regeneration, and is currently actively being studied for tissue engineering purposes. The biomechanical and biochemical effects of HA on the local microenvironment of the injected site are key to its success as a soft tissue filler. Knowledge of the tissue-device interface will help guide the facial practitioner and lead to optimal outcomes for patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Microvascular complications associated with injection of cosmetic facelift dermal fillers
NASA Astrophysics Data System (ADS)
Yousefi, Siavash; Prendes, Mark; Chang, Shu-Hong; Wang, Ruikang K.
2015-02-01
Minimally-invasive cosmetic surgeries such as injection of subdermal fillers have become very popular in the past decade. Although rare, some complications may follow injections such as tissue necrosis and even blindness. There exist two hypothesis regarding source of these complications both of which include microvasculature. The first hypothesis is that fillers in between the tissue structures and compress microvasculature that causes blockage of tissue neutrition and oxygen exchange in the tissue. In another theory, it is hypothesized that fillers move inside major arteries and block the arteries/veins. In this paper, we study these hypotheses using optical coherence tomography and optical microangiography technologies with different hyaluronic-acid fillers in a mouse ear model. Based on our observations, the fillers eventually block arteries/veins if injected directly into them that eventually causes tissue necrosis.
Injectable fillers: review of material and properties.
Attenello, Natalie Huang; Maas, Corey S
2015-02-01
With an increasing understanding of the aging process and the rapidly growing interest in minimally invasive treatments, injectable facial fillers have changed the perspective for the treatment and rejuvenation of the aging face. Other than autologous fat and certain preformed implants, the collagen family products were the only Food and Drug Administration approved soft tissue fillers. But the overwhelming interest in soft tissue fillers had led to the increase in research and development of other products including bioengineered nonpermanent implants and permanent alloplastic implants. As multiple injectable soft tissue fillers and biostimulators are continuously becoming available, it is important to understand the biophysical properties inherent in each, as these constitute the clinical characteristics of the product. This article will review the materials and properties of the currently available soft tissue fillers: hyaluronic acid, calcium hydroxylapatite, poly-l-lactic acid, polymethylmethacrylate, and autologous fat (and aspirated tissue including stem cells). Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Facial soft-tissue fillers conference: assessing the state of the science.
Rohrich, Rod J; Hanke, C William; Busso, Mariano; Carruthers, Alastair; Carruthers, Jean; Fagien, Steven; Fitzgerald, Rebecca; Glogau, Richard; Greenberger, Phyllis E; Lorenc, Z Paul; Marmur, Ellen S; Monheit, Gary D; Pusic, Andrea; Rubin, Mark G; Rzany, Berthold; Sclafani, Anthony; Taylor, Susan; Weinkle, Susan; McGuire, Michael F; Pariser, David M; Casas, Laurie A; Collishaw, Karen J; Dailey, Roger A; Duffy, Stephen C; Edgar, Elizabeth Jan; Greenan, Barbara L; Haenlein, Kelly; Henrichs, Ronald A; Hume, Keith M; Lum, Flora; Nielsen, David R; Poulsen, Lisle; Shoaf, Lori; Schoaf, Lori; Seward, William; Begolka, Wendy Smith; Stanton, Robert G; Svedman, Katherine J; Thomas, J Regan; Sykes, Jonathan M; Wargo, Carol; Weiss, Robert A
2011-04-01
: The American Society of Plastic Surgeons and the American Academy of Dermatology, with the support of other sister societies, conducted the Facial Soft-Tissue Fillers: Assessing the State of the Science conference in December of 2009. The American Society of Plastic Surgeons and the American Academy of Dermatology established a panel of leading experts in the field of soft-tissue fillers-from researchers to clinicians-and other stakeholders for the conference to examine and discuss issues of patient safety, efficacy, and effectiveness in relation to the approved and off-label use of soft-tissue fillers, and other factors, including the training and level of experience of individuals administering fillers. This report represents the systematic literature review that examines comprehensively the available evidence and gaps in the evidence related to soft-tissue fillers, to inform and support the work of the state-of-the-science conference panel. This evidence-based medicine review will serve as the foundation for future evidence-based medicine reports in this growing field.
Shimazu, Kisaki; Ogata, Kiyokazu; Karibe, Hiroyuki
2012-01-01
We aimed to evaluate the caries-preventive effect of a fissure sealant containing surface reaction-type pre-reacted glass ionomer (S-PRG) filler and bonded by self-etching primer versus those of 2 conventional resin-based sealants bonded by acid etching in terms of its impact on enamel demineralization and remineralization, enamel bond strength, and integrity of debonded enamel surfaces. Demineralization, remineralization, and bond strength on untreated enamel and enamel subsurface lesions of bovine incisors were assessed among the sealants by polarizing microscopy and microradiography; debonded enamel surfaces were examined by scanning electron microscopy. The conventional resin-based sealants bonded by acid etching caused surface defects on the enamel subsurface lesions and significantly increased the lesion depth (p = 0.014), indicative of enamel demineralization. However the S-PRG filler-containing sealant bonded by self-etching primer maintained the enamel surface integrity and inhibited enamel demineralization. No difference in bond strength on both untreated enamel and enamel subsurface lesions was noted among the sealants. An S-PRG filler-containing fissure sealant bonded by self-etching primer can prevent enamel demineralization, microleakage, and gaps without the tags created by acid etching regardless of the enamel condition. Such sealants are suitable for protecting the pits and fissures of immature permanent teeth.
Effect of the coating material on root dentin remineralization in vitro.
Shiiya, Toru; Tomiyama, Kiyoshi; Iizuka, Junko; Hasegawa, Haruhiko; Kuramochi, Erika; Fujino, Fukue; Ohashi, Katsura; Nihei, Tomotaro; Teranaka, Toshio; Mukai, Yoshiharu
2014-10-01
A fluoride-releasing coating material containing surface pre-reacted glass-ionomer (S-PRG) filler has become commercially available. However, there has been no detailed investigation of its remineralization effects at various tooth surface regions. The remineralization effects of S-PRG filler-containing coating material at different sites of demineralized dentin surfaces in vitro were evaluated. Baseline lesions were prepared on bovine root dentin surfaces by immersion in demineralization buffer and divided into four groups: (B)--baseline lesion; (P)--S-PRG filler-containing material; (V)--S-PRG filler-free coating material as negative control; and (X)--resin-modified glass- ionomer as positive control. Material was applied to half the lesion surface, then P, V and X were remineralized in a gel system. Mineral profiles, integrated mineral loss (IML) and lesion depth (LD) at four regions, i.e. 1--exposed dentin surface adjacent to the material; 2--at a distance from the material; 3--beneath the material near to the edge; and 4--at a distance from the edge, were analyzed by transversal microradiography. Data were analyzed using ANOVA and Games-Howell test with α = 0.05. B showed typical artificial demineralized lesion. The IMLs of V, P and X at regions 1 and 2, and P and X at region 3 were significantly lower than that of B, however, those of V at region 3 and the other three groups at region 4 were not significantly different from that of B. At region 1, P and X showed significantly lower IMLs than V. At region 2, the IML of X showed significantly lower IML than V. There was no significant difference between P and X. The LD values of V, P and X at all regions were not significantly different from that of B. Fluoride, strontium and silicate ions released from the S-PRG filler would provide a favorable environment for remineralization of the demineralized dentin in P.
Hyaluronic acid gel distribution pattern in periocular area with high-resolution ultrasound imaging.
Goh, Alice S; Kohn, Jocelyne C; Rootman, Daniel B; Lin, Joseph L; Goldberg, Robert A
2014-05-01
High-resolution ultrasound (HRUS) is a useful tool in defining anatomic and dynamic soft tissue relationships in the periocular area. It also allows visualization of hyaluronic acid (HA) gel within the soft tissue. The authors investigate the difference in the distribution pattern between 2 HA fillers in the periocular tissue using HRUS. The charts of 10 patients who underwent periocular injection using HA gel filler and were subsequently examined with HRUS were reviewed. Half of the patients (n = 5) were treated with Restylane-L (Medicis Aesthetics, Inc, Scottsdale, Arizona) and the remaining 5 with Belotero Balance (Merz Aesthetics, Inc, San Mateo, California). Ultrasonographic evaluation (Logiq p6; GE Healthcare, Waukesha, Washington) was performed before and immediately after HA filler injection. The HA appears as a hypoechoic image within the soft tissue plane on HRUS. Restylane-L filler formed a localized hypoechoic image within the tissue, with some spread into bubbles or pearl-like configuration. Belotero Balance spread more widely into the tissue plane and diffused into an elongated or spindle-shaped hypoechoic image. Our preliminary data suggest that HA gel fillers with differing production technologies show distinct spread and distribution patterns in the periocular tissues on HRUS examination.
Jeong, Ki Heon; Gwak, Min Jae; Moon, Sung Kyung; Lee, Sang Jun; Shin, Min Kyung
2018-06-01
Various hyaluronic acid fillers can be used for facial attenuation and rejuvenation. The efficacy and durability of hyaluronic acid fillers are of major concern to dermatologists and patients. This study aimed to evaluate three-dimensional morphology, tissue distribution, and changes in volume after injection of two different hyaluronic acid fillers. Ten Korean women were enrolled in this study. Each subject was injected with monophasic hyaluronic acid filler in one malar area and biphasic filler in the other. Clinical outcome was measured before and after injection, and after 2, 4, 6, 8, 12, and 24 weeks, using the Global Aesthetic Improvement Scale, photographs and Moire's topography. Facial magnetic resonance imaging (MRI) was performed twice over six months. Both products showed good results after injection and demonstrated good durability over time. MRI was a useful modality for assessing tissue distribution and volume changes. The effects and durability after injection of monophasic hyaluronic acid filler and biphasic hyaluronic acid filler are generally comparable.
Sclafani, Anthony P; Pizzi, Laura; Jutkowitz, Eric; Mueller, Nancy; Jung, Matthew
2010-08-01
Patient-reported outcomes data are limited after injectable soft tissue filler treatment. Patient-reported outcome measures (PROMs) are becoming integral to medical practices in other specialties and will become so as well in facial plastic surgery. The obvious differences in types of disorders treated and the outcomes of primary importance seen between general medical/surgical and facial plastic surgery practices make institution of standard outcomes studies difficult in facial plastic surgery. However, understanding the patient's experience and satisfaction with treatment is essential to continue to provide excellent care to facial aesthetic patients. This article describes use of a new survey instrument, Facial Injectables: Longevity, Late and Early Reactions and Satisfaction Questionnaire (FILLERS-Q), in assessing patient response to facial injections of soft tissue fillers. FILLERS-Q is a 43-item questionnaire that captures patient demographics (4 items), patient satisfaction with treatment (10 items), procedure-related events (3 to 7 items), impact on relationships (9 to 15 items), and economic considerations related to dermal filler treatment (3 to 7 items). The results provide a "snapshot" of patients treated in an individual surgeon's practice. (c) Thieme Medical Publishers.
Fillers in dermatology: from past to present.
Chacon, Anna H
2015-11-01
Injectable fillers were introduced in dermatology as a method for reconstructing facial deformities and restoring the aging face. Although fillers have become a popular option among cosmetic patients, clinical experience has shown that fillers must be used with caution, as complications can occur. This article provides a brief review of the history of filler agents currently available for soft tissue augmentation. Although no single filler is ideal for all patients, indications, and situations, residents should be aware of the properties and characteristics that make each product unique.
Franchi, G; Neiva-Vaz, C; Picard, A; Vazquez, M-P
2018-06-01
Cross-linked hyaluronic acid-based fillers have gained rapid acceptance for treating facial wrinkles, deep tissue folds and sunken areas due to aging. This study evaluates, in addition to space-filling properties, their effects on softness and elasticity as a secondary effect, following injection of 3 commercially available cross-linked hyaluronic acid-based fillers (15mg/mL, 17,5mg/mL and 20mg/mL) in patients presenting with congenital or acquired facial malformations. We started injecting gels of cross-linked hyaluronic acid-based fillers in those cases in 2013; we performed 46 sessions of injections in 32 patients, aged from 13-32. Clinical assessment was performed by the patient himself and by a plastic surgeon, 15 days after injections and 6-18 months later. Cross-linked hyaluronic acid-based fillers offered very subtle cosmetic results and supplemented surgery with a very high level of satisfaction of the patients. When injected in fibrosis, the first session enhanced softness and elasticity; the second session enhanced the volume. Cross-linked hyaluronic acid-based fillers fill sunken areas and better softness and elasticity of scar tissues. In addition to their well-understood space-filling function, as a secondary effect, the authors demonstrate that cross-linked hyaluronic acid-based fillers improve softness and elasticity of scarring tissues. Many experimental studies support our observations, showing that cross-linked hyaluronic acid stimulates the production of several extra-cellular matrix components, including dermal collagen and elastin. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Fakhari, Amir; Berkland, Cory
2013-01-01
Hyaluronic acid (HA) is a naturally occurring biodegradable polymer with a variety of applications in medicine including scaffolding for tissue engineering, dermatological fillers, and viscosupplementation for osteoarthritis treatment. HA is available in most connective tissues in body fluids such as synovial fluid and the vitreous humor of the eye. HA is responsible for several structural properties of tissues as a component of extracellular matrix (ECM) and is involved in cellular signaling. Degradation of HA is a step-wise process that can occur via enzymatic or non-enzymatic reactions. A reduction in HA mass or molecular weight via degradation or slowing of synthesis affects physical and chemical properties such as tissue volume, viscosity, and elasticity. This review addresses the distribution, turnover, and tissue-specific properties of HA. This information is used as context for considering recent products and strategies for modifying the viscoelastic properties of HA in tissue engineering, as a dermal filler, and in osteoarthritis treatment. PMID:23507088
Effects of Ion-Releasing Tooth-Coating Material on Demineralization of Bovine Tooth Enamel
Kawasaki, Koji; Kambara, Masaki
2014-01-01
We compared the effect of a novel ion-releasing tooth-coating material that contained S-PRG (surface-reaction type prereacted glass-ionomer) filler to that of non-S-PRG filler and nail varnish on the demineralization of bovine enamel subsurface lesions. The demineralization process of bovine enamel was examined using quantitative light-induced fluorescence (QLF) and electron probe microanalyzer (EPMA) measurement. Ion concentrations in demineralizing solution were measured using inductively coupled plasma atomic (ICP) emission spectrometry and an ion electrode. The nail varnish group and the non-S-PRG filler group showed linear demineralization. Although the nail varnish group and the non-S-PRG filler group showed linear demineralization, the S-PRG filler group did not. Further, plane-scanning by EPMA analysis in the S-PRG filler group showed no changes in Ca ion distribution, and F ions showed peak levels on the surface of enamel specimens. Most ions in the demineralizing solution were present at higher concentrations in the S-PRG filler group than in the other two groups. In conclusion, only the S-PRG filler-containing tooth-coating material released ions and inhibited demineralization around the coating. PMID:24578706
Effect of monopolar radiofrequency treatment over soft-tissue fillers in an animal model: part 2.
Shumaker, Peter R; England, Laura J; Dover, Jeffrey S; Ross, E Victor; Harford, Robert; Derienzo, Damian; Bogle, Melissa; Uebelhoer, Nathan; Jacoby, Mark; Pope, Karl
2006-03-01
Monopolar radiofrequency (RF) treatment is used by physicians to heat skin and promote tissue tightening and contouring. Cosmetic fillers are used to soften deep facial lines and wrinkles. Patients who have had dermal fillers implanted may also benefit from or are candidates for monopolar RF skin tightening. This study examined the effect of RF treatment on various dermal filler substances. This is the second part of a two-part study. A juvenile farm pig was injected with dermal fillers including cross-linked human collagen (Cosmoplast), polylactic acid (PLA) (Sculptra), liquid injectable silicone (Silikon 1000), calcium hydroxylapatite (CaHA) (Radiesse), and hyaluronic acid (Restylane). Skin injected with dermal fillers was RF-treated using a 1.5-cm2 treatment tip and treatment levels typically used in the clinical setting. Fillers were examined histologically 5 days, 2 weeks, or 1 month after treatment. Histological specimens were scored for inflammatory response, foreign body response, and fibrosis in order to assess the effect of treatment on early filler processes, such as inflammation and encapsulation. Each filler substance produced a characteristic inflammatory response. No immediate thermal effect of RF treatment was observed histologically. RF treatment resulted in statistically significant increases in the inflammatory, foreign body, and fibrotic responses associated with the filler substances. Monopolar RF treatment levels that are typically used in the clinical setting were employed in this animal study. RF treatment resulted in measurable and statistically significant histological changes associated with the various filler materials. Additional clinical and histological studies are required to determine the optimal timing of monopolar RF treatment and filler placement for maximal potential aesthetic outcome. 2006 Wiley-Liss, Inc.
Ledon, Jennifer A; Savas, Jessica A; Yang, Steven; Franca, Katlein; Camacho, Ivan; Nouri, Keyvan
2013-10-01
Nodule development is a common complication following the use of fillers for soft tissue augmentation and is commonly categorized as inflammatory or non-inflammatory in nature. Inflammatory nodules may appear anywhere from days to years after treatment, whereas non-inflammatory nodules are typically seen immediately following implantation and are usually secondary to improper placement of the filler. Although inflammatory nodules are more common with permanent fillers such as silicone, inflammatory nodule development following administration of temporary fillers such as hyaluronic acid and collagen has also been reported. Treated many times with corticosteroids due to their anti-inflammatory properties, inflammatory nodules may be secondary to infection or biofilm formation, warranting the use of alternative agents. Appropriate and prompt diagnosis is important in avoiding delay of treatment or long-term complications for the patient. This paper addresses the etiology, development, and studied treatment options available for inflammatory nodules secondary to each of the major classes of fillers. With this knowledge, practitioners may expeditiously recognize and manage this common side effect and thus maximize functional and aesthetic benefit.
... A sore at the injection site Allergic reaction Necrosis (tissue death) The following rare side effects have ... injection, and do not inject dermal fillers into blood vessels in the face. Before injection, thoroughly inform the ...
What Are Your Patients Reading Online About Soft-tissue Fillers? An Analysis of Internet Information
Al Youha, Sarah A.; Bull, Courtney E.; Butler, Michael B.; Williams, Jason G.
2016-01-01
Background: Soft-tissue fillers are increasingly being used for noninvasive facial rejuvenation. They generally offer minimal downtime and reliable results. However, significant complications are reported and patients need to be aware of these as part of informed consent. The Internet serves as a vital resource to inform patients of the risks and benefits of this procedure. Methods: Three independent reviewers performed a structured analysis of 65 Websites providing information on soft-tissue fillers. Validated instruments were used to analyze each site across multiple domains, including readability, accessibility, reliability, usability, quality, and accuracy. Associations between the endpoints and Website characteristics were assessed using linear regression and proportional odds modeling. Results: The majority of Websites were physician private practice sites (36.9%) and authored by board-certified plastic surgeons or dermatologists (35.4%) or nonphysicians (27.7%). Sites had a mean Flesch-Kincaid grade level of 11.9 ± 2.6, which is well above the recommended average of 6 to 7 grade level. Physician private practice sites had the lowest scores across all domains with a notable lack of information on complications. Conversely, Websites of professional societies focused in plastic surgery and dermatology, as well as academic centers scored highest overall. Conclusions: As the use of soft-tissue fillers is rising, patients should be guided toward appropriate sources of information such as Websites sponsored by professional societies. Medical professionals should be aware that patients may be accessing poor information online and strive to improve the overall quality of information available on soft-tissue fillers. PMID:27536503
Kim, H J; Kwon, S B; Whang, K U; Lee, J S; Park, Y L; Lee, S Y
2018-02-01
Hyaluronidase injection is a commonly performed treatment for overcorrection or misplacement of hyaluronic acid (HA) filler. Many patients often wants the HA filler reinjection after the use of hyaluronidase, though the optimal timing of reinjection of HA filler still remains unknown. To provide the optimal time interval between hyaluronidase injections and HA filler reinjections. 6 Sprague-Dawley rats were injected with single monophasic HA filler. 1 week after injection, the injected sites were treated with hyaluronidase. Then, HA fillers were reinjected sequentially with differing time intervals from 30 minutes to 14 days. 1 hour after the reinjection of the last HA filler, all injection sites were excised for histologic evaluation. 3 hours after reinjection of HA filler, the appearance of filler material became evident again, retaining its shape and volume. 6 hours after reinjection, the filler materials restored almost its original volume and there were no significant differences from the positive control. Our data suggest that the hyaluronidase loses its effect in dermis and subcutaneous tissue within 3-6 hours after the injection and successful engraftment of reinjected HA filler can be accomplished 6 hours after the injection.
Hwang, Catherine J; Morgan, Payam V; Pimentel, Aline; Sayre, James W; Goldberg, Robert A; Duckwiler, Gary
2016-01-01
Soft tissue dermal fillers, both temporary and permanent, are used frequently in facial rejuvenation. As the use of fillers increases, ischemic complications including skin necrosis are becoming more prevalent. In the literature, topical nitroglycerin paste has been recommended in the early treatment of patients presenting with ischemia. The purpose of this study was to evaluate the vascular perfusion effects of topical nitroglycerin paste in an animal model using indocyanine green (ICG) imaging. After Animal Research Committee approval, a rabbit ear model was used to create filler-associated skin ischemia. Ischemia was confirmed to occur after intra-arterial occlusion. Four commonly used soft tissue fillers were injected intra-arterially: Radiesse (Merz USA, Greensboro NC), Restylane (Galderma, Ft. Worth, TX), Juvederm Ultra (Allergan, Irvine CA), Belotero (Merz USA, Greensboro NC) (0.1 ml). A total of 15 ears were used, 1 control and 4 experimental per product. Thirty minutes after occlusion, nitroglycerin ointment USP, 2%(Nitro-Bid) was applied topically to the experimental ears. Vascular perfusion was evaluated with the SPY System (Novadaq Inc.) using ICG imaging. Perfusion images were obtained at baseline, immediately after, and 30 minutes after intra-arterial filler injection, and at 30, 60, 90, and 120 minutes after application of topical nitroglycerin ointment. In this rabbit ear model, no statistically significant improvement in perfusion was noted after topical application of nitroglycerin paste with ICG imaging. In addition, the skin of the rabbit ear post-nitroglycerin ointment appeared to have more of a congested appearance than the controls. Ischemic filler complications are becoming increasingly prevalent. Practitioners often treat these complications with topical nitroglycerin paste based on the knowledge that topical nitroglycerin causes vasodilation. In filler-induced tissue ischemia, however, filler product is present within arterioles. Theoretically, applying nitroglycerin paste, at least early, may not improve perfusion and could worsen ischemia with dilation of vessels and further propagation of product into the smaller arterioles and capillaries. In addition, nitroglycerin paste has systemic effects, including hypotension and dizziness, which may not be tolerated by some patients. Therefore, the authors caution the use of topical nitroglycerin paste in patients presenting with filler-associated ischemia. Further studies in the best treatment algorithms for patients presenting with ischemic complications need to be performed.
Fillers: from the past to the future.
Glogau, Richard G
2012-06-01
Modern medical use of injectable soft-tissue augmentation fillers has evolved from the introduction of bovine collage implants to an array of synthesized materials in the current domestic and foreign markets. The concept of augmentation has moved from simple lines, scars, and wrinkles to revolumizing the aging face. A brief overview of the past, present, and future injectable fillers is presented. Copyright © 2012 Elsevier Inc. All rights reserved.
Natural Rubber Nanocomposite with Human-Tissue-Like Mechanical Characteristic
NASA Astrophysics Data System (ADS)
Murniati, Riri; Novita, Nanda; Sutisna; Wibowo, Edy; Iskandar, Ferry; Abdullah, Mikrajuddin
2017-07-01
The blends of synthetic rubber and natural rubber with nanosilica were prepared using a blending technique in presence of different filler volume fraction. The effect of filler on morphological and mechanical characteristics was studied. Utilization of human cadaver in means of medical study has been commonly used primarily as tools of medical teaching and training such as surgery. Nonetheless, human cadaver brought inevitable problems. So it is necessary to find a substitute material that can be used to replace cadavers. In orthopaedics, the materials that resemble in mechanical properties to biological tissues are elastomers such as natural rubber (latex) and synthetic rubber (polyurethanes, silicones). This substitution material needs to consider the potential of Indonesia to help the development of the nation. Indonesia is the second largest country producer of natural rubber in the world. This paper aims to contribute to adjusting the mechanical properties of tissue-mimicking materials (TMMs) to the recommended range of biological tissue value and thus allow the development of phantoms with greater stability and similarity to human tissues. Repeatability for the phantom fabrication process was also explored. Characteristics were then compared to the control and mechanical characteristics of different human body part tissue. Nanosilica is the best filler to produce the best nanocomposite similarities with human tissue. We produced composites that approaching the properties of human internal tissues.
Scleroderma en coup de sabre treated with polymethylmethacrylate - Case report.
Franco, Joanna Pimenta de Araujo; Serra, Márcio Soares; Lima, Ricardo Barbosa; D'Acri, Antônio Macedo; Martins, Carlos José
2016-04-01
The scleroderma en coup de sabre is a variant of localized scleroderma that occurs preferentially in children. The disease progresses with a proliferative and inflammatory phase and later atrophy and residual deformity, which are treated with surgical techniques such as injectable fillers, transplanted or autologous fat grafting and resection of the lesion. Among the most widely used fillers is hyaluronic acid. However, there are limitations that motivate the search for alternatives, such as polymethylmethacrylate, a permanent filler that is biocompatible, non-toxic, non-mutagenic and immunologically inert. In order to illustrate its application, a case of scleroderma en coup de sabre in a 17-year-old patient, who was treated with polymethylmethacrylate with excellent aesthetic results, is reported.
Ju, Dandan; Han, Lijing; Li, Zonglin; Chen, Yunjing; Wang, Qingjiang; Bian, Junjia; Dong, Lisong
2016-05-20
Porous poly(L-lactic acid) (PLLA) sheets were prepared by uniaxial stretching PLLA sheets containing starch filler. Here, the starch filler content, stretching ratio, stretching rate and stretching temperature are important factors to influence the structure of the porous PLLA sheets, therefore, they have been investigated in detail. The pore size distribution and tortuosity were characterized by Mercury Intrusion Porosimetry. The results revealed that the porosity and pore size enlarged with the increase of the starch filler content and stretching ratio, while shrank with the rise of stretching temperature. On the other hand, the pore structure almost had no changes with the stretching rate ranging between 5 and 40 mm/min. In order to test and verify that the porous PLLA sheet was suitable for the tissue engineering, the starch particles were removed by selective enzymatic degradation and its in vitro biocompatibility to osteoblast-like MC3T3-E1 cells was investigated. Copyright © 2016 Elsevier Ltd. All rights reserved.
Before and After Photos: Treatment of Hypertrophic Scars
... Injectable Poly-l-lactic Acid Injectable Polymethylmethacrylate + Bovine Collagen Filler Injectable Calcium Hydroxylapatite Back Laser/light Therapy ... attempts to repair these lesions by forming new collagen fibers. These repairs usually aren't as smooth ...
Wollina, Uwe
2016-03-01
Facial aging is a major indication for minimal invasive esthetic procedures. Dermal fillers are a cornerstone in the approach for facial sculpturing. But where to start? Our concept is midfacial volume restoration in first place. This will result in a healthy and youthful appearance creating a facial V-shape. But midfacial filler injection does not only improve the malar area. It has also beneficial effects on neighboring esthetic units. We report on such improvements in periocular and nasolabial region, upper lips and perioral tissue, and the jaw line and discuss anatomical background. We hypothesize that midfacial deep filler injections also may activate subdermal white adipose tissue stem cells contributing to longer lasting rejuvenation. © 2015 Wiley Periodicals, Inc.
Technical Considerations for Filler and Neuromodulator Refinements
Wilson, Anthony J.; Chang, Brian L.; Percec, Ivona
2016-01-01
Background: The toolbox for cosmetic practitioners is growing at an unprecedented rate. There are novel products every year and expanding off-label indications for neurotoxin and soft-tissue filler applications. Consequently, aesthetic physicians are increasingly challenged by the task of selecting the most appropriate products and techniques to achieve optimal patient outcomes. Methods: We employed a PubMed literature search of facial injectables from the past 10 years (2005–2015), with emphasis on those articles embracing evidence-based medicine. We evaluated the scientific background of every product and the physicochemical properties that make each one ideal for specific indications. The 2 senior authors provide commentary regarding their clinical experience with specific technical refinements of neuromodulators and soft-tissue fillers. Results: Neurotoxins and fillers are characterized by unique physical characteristics that distinguish each product. This results in subtle but important differences in their clinical applications. Specific indications and recommendations for the use of the various neurotoxins and soft-tissue fillers are reviewed. The discussion highlights refinements in combination treatments and product physical modifications, according to specific treatment zones. Conclusions: The field of facial aesthetics has evolved dramatically, mostly secondary to our increased understanding of 3-dimensional structural volume restoration. Our work reviews Food and Drug Administration–approved injectables. In addition, we describe how to modify products to fulfill specific indications such as treatment of the mid face, décolletage, hands, and periorbital regions. Although we cannot directly evaluate the duration or exact physical properties of blended products, we argue that “product customization” is safe and provides natural results with excellent patient outcomes. PMID:28018778
Inbal, Amir; Lemelman, Benjamin T; Millet, Eran; Greensmith, Andrew
2017-10-16
Auricular reconstruction is one of the most challenging procedures in plastic surgery. An adequate skin envelope is essential for cartilage framework coverage, yet few good options exist without additional surgery. We propose a novel method for minimally invasive tissue expansion, using hyaluronic acid (HA) filler to allow for single-stage ear reconstruction. To introduce the novel concept of HA filler for tissue expansion in ear reconstruction, and as an alternative to traditional expansion techniques. Macrolane is a large particle HA gel developed for large volume restoration. Expansion of the non-hair-bearing mastoid skin was performed in our clinic weekly or every other week. Final expansion was completed one week prior to reconstructive surgery. Tissue from one patient's expanded pocket was sent for histological analysis. Ten patients underwent single-stage auricular reconstruction with preoperative expansion. Injection sessions ranged from 7 to 13 (mean, 9.7). Mean injected volume per session was 2.03 mL per patient, for an average total of 19.8 mL (range, 14.5-30 mL). There were no major complications. One minor complication required removal of exposed wire from the antihelix in the office. Hematoxylin and eosin stain revealed similar histology to that seen with traditional expanders. This novel expansion technique using serial HA injections allowed for optimized skin coverage in single-stage ear reconstruction. The concept of tissue expansion using HA filler is a new frontier for research that may be applicable to other arenas of reconstruction. 4. © 2017 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Autologous fat transplantation for the treatment of linear scleroderma en coup de sabre.
Ibler, Kristina S; Gramkow, Christina; Siemssen, Peter A
2015-01-01
Scleroderma en coup de sabre is a disfiguring disease for which only limited therapeutic options exist. Three cases of facial linear scleroderma treated with autologous fat transplantation with acceptable results are presented. Autologous fat transplantation was preferred to corrective surgery because of the extent of the lesions and absence of any associated facial distortion. Fat as a filler was chosen to reduce the risk of adverse effects. Adipocytes are suggested to have wider biological effects than other fillers and may offer more durable results. At least two transplantations were needed to evoke a significant effect.
Lemperle, Gottfried; Morhenn, Vera; Charrier, Ulrich
2003-01-01
An increasing number of soft tissue filler substances have been introduced to the beauty market outside the U.S. which lack experimental and clinical data in support of their claim. Ten commercially available filler substances were examined for biocompatibility and durability: 0.1 cc of each substance was injected deep intradermally into the volar forearm of one of the authors and observed for clinical reaction and permanence. At 1, 3, 6, and 9 months the test sites were excised, histologically examined, and graded according to foreign body reactions classification. Collagen (Zyplast) was phagocytosed at 6 months and hyaluronic acid (Restylane) at 9 months. PMMA microspheres (Artecoll) had encapsulated with connective tissue, macrophages, and sporadic giant cells. Silicone oil (PMS 350) was clinically inconspicuous but dissipated into the tissue, causing a chronic foreign body reaction. Polylactic acid microspheres (New-Fill) induced a mild inflammatory response and had disappeared clinically at 4 months. Dextran microspheres (Reviderm intra) induced a pronounced foreign body reaction and had disappeared at 6 months. Polymethylacrylate particles (Dermalive) induced the lowest cellular reaction but had disappeared clinically at 6 months. Polyacrylamide (Aquamid) was well tolerated and remained palpable to a lessening degree over the entire testing period. Histologically, it dissipated more slowly and was kept in place through fine fibrous capsules. Polyvinylhydroxide microspheres suspended in acrylamide (Evolution) were well tolerated, slowly diminishing over 9 months. Calcium hydroxylapatite microspheres (Radiance FN) induced almost no foreign body reaction but were absorbed by the skin at 12 months. Host defense mechanisms react differently to the various filler materials, but all substances-resorbable or nonresorbable-appeared to be clinically and histologically safe, although all exhibit undesirable side effects. Since the mechanism of late inflammation or granuloma formation is still unknown, early histological findings are not useful in predicting possible late reactions to filler substances.
Prasetyo, Adri D; Prager, Welf; Rubin, Mark G; Moretti, Ernesto A; Nikolis, Andreas
2016-01-01
Background Cohesive monophasic polydensified fillers show unique viscoelastic properties and variable density of hyaluronic acid, allowing for a homogeneous tissue integration and distribution of the material. Objective The aim of this paper was to review the clinical data regarding the performance, tolerability, and safety of the Belotero® fillers for soft-tissue augmentation and rejuvenation. Methods A literature search was performed up until May 31, 2015 to identify all relevant articles on Belotero® fillers (Basic/Balance, Hydro, Soft, Intense, Volume) and equivalent products (Esthélis®, Mesolis®, Fortélis®, Modélis®). Results This comprehensive review included 26 papers. Findings from three randomized controlled trials showed a greater reduction in nasolabial fold severity with Belotero® Basic/Balance than with collagen (at 8, 12, 16, and 24 weeks, n=118) and Restylane® (at 4 weeks, n=40), and higher patient satisfaction with Belotero® Intense than with Perlane® (at 2 weeks, n=20). With Belotero® Basic/Balance, an improvement of at least 1 point on the severity scale can be expected in ~80% of patients 1–6 months after injection, with an effect still visible at 8–12 months. Positive findings were also reported with Belotero® Volume (no reduction in hyaluronic acid volume at 12 months, as demonstrated by magnetic resonance imaging), Soft (improvement in the esthetic outcomes when used in a sequential approach), and Hydro (improvement in skin appearance in all patients). The most common adverse effects were mild-to-moderate erythema, edema, and hematoma, most of which were temporary. There were no reports of Tyndall effect, nodules, granulomas, or tissue necrosis. Conclusion Clinical evidence indicates sustainable esthetic effects, good safety profile, and long-term tolerability of the Belotero® fillers, particularly Belotero® Basic/Balance and Intense. PMID:27660479
Sridhar, Jayanth; Shahlaee, Abtin; Shieh, Wen-Shi; Rahimy, Ehsan
2017-01-01
To report a single case of paracentral acute middle maculopathy in association with retinal artery occlusion in the setting of ipsilateral facial cosmetic filler injection. Case report. A 35-year-old woman presenting with sudden vision loss to finger count vision immediately after left nasal fat pad cosmetic filler injection. Dilated funduscopic examination revealed a swollen optic disc with multiple branch arterial occlusions with visible embolic material. Fluorescein angiography confirmed multiple branch arterial occlusions in addition to a focal choroidal infarction in the macula. Spectral-domain optical coherence tomography revealed middle retinal hyperreflectivity in the superotemporal macula consistent with paracentral acute middle maculopathy. En face optical coherence tomography demonstrated a superotemporal area of whitening at the level of the deep capillary plexus corresponding to the paracentral acute middle maculopathy lesion seen on spectral-domain optical coherence tomography. On twelve-month follow-up, final visual acuity was 20/100 due to optic neuropathy. Emboli from cosmetic facial filler injections may rarely result in ipsilateral arterial occlusions and now have a novel association with paracentral acute middle maculopathy likely due to deep capillary plexus feeder vessel occlusion.
Kleydman, Kate; Cohen, Joel L; Marmur, Ellen
2012-12-01
Skin necrosis after soft tissue augmentation with dermal fillers is a rare but potentially severe complication. Nitroglycerin paste may be an important treatment option for dermal and epidermal ischemia in cosmetic surgery. To summarize the knowledge about nitroglycerin paste in cosmetic surgery and to understand its current use in the treatment of vascular compromise after soft tissue augmentation. To review the mechanism of action of nitroglycerin, examine its utility in the dermal vasculature in the setting of dermal filler-induced ischemia, and describe the facial anatomy danger zones in order to avoid vascular injury. A literature review was conducted to examine the mechanism of action of nitroglycerin, and a treatment algorithm was proposed from clinical observations to define strategies for impending facial necrosis after filler injection. Our experience with nitroglycerin paste and our review of the medical literature supports the use of nitroglycerin paste on the skin to help improve flow in the dermal vasculature because of its vasodilatory effect on small-caliber arterioles. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.
Hybrid Hydroxyapatite Nanoparticle Colloidal Gels are Injectable Fillers for Bone Tissue Engineering
Gu, Zhen; Jamal, Syed; Detamore, Michael S.
2013-01-01
Injectable bone fillers have emerged as an alternative to the invasive surgery often required to treat bone defects. Current bone fillers may benefit from improvements in dynamic properties such as shear thinning during injection and recovery of material stiffness after placement. Negatively charged inorganic hydroxyapatite (HAp) nanoparticles (NPs) were assembled with positively charged organic poly(d,l-lactic-co-glycolic acid) (PLGA) NPs to create a cohesive colloidal gel. This material is held together by electrostatic forces that may be disrupted by shear to facilitate extrusion, molding, or injection. Scanning electron micrographs of the dried colloidal gels showed a well-organized, three-dimensional porous structure. Rheology tests revealed that certain colloidal gels could recover after being sheared. Human umbilical cord mesenchymal stem cells were also highly viable when seeded on the colloidal gels. HAp/PLGA NP colloidal gels offer an attractive scheme for injectable filling and regeneration of bone tissue. PMID:23815275
Avoiding and Treating Blindness From Fillers: A Review of the World Literature.
Beleznay, Katie; Carruthers, Jean D A; Humphrey, Shannon; Jones, Derek
2015-10-01
As the popularity of soft tissue fillers increases, so do the reports of adverse events. The most serious complications are vascular in nature and include blindness. To review the cases of blindness after filler injection, to highlight key aspects of the vascular anatomy, and to discuss prevention and management strategies. A literature review was performed to identify all the cases of vision changes from filler in the world literature. Ninety-eight cases of vision changes from filler were identified. The sites that were high risk for complications were the glabella (38.8%), nasal region (25.5%), nasolabial fold (13.3%), and forehead (12.2%). Autologous fat (47.9%) was the most common filler type to cause this complication, followed by hyaluronic acid (23.5%). The most common symptoms were immediate vision loss and pain. Most cases of vision loss did not recover. Central nervous system complications were seen in 23.5% of the cases. No treatments were found to be consistently successful in treating blindness. Although the risk of blindness from fillers is rare, it is critical for injecting physicians to have a firm knowledge of the vascular anatomy and to understand key prevention and management strategies.
Coronado-Malagón, Martín; Visoso-Palacios, Porfirio; Arce-Salinas, C Alejandro
2010-01-01
There are no reports in the literature of an association between soft tissue filler (STF) injection and fat embolism syndrome (FES). The authors present the case of a 26-year-old woman who was injected in the gluteal area with approximately 200 cc of STF on each side for aesthetic purposes. After this procedure, she presented with the triad of hypoxemia, neurological impairment, and petechiae consistent with the diagnosis of FES. After advanced support measures, she recovered completely. This article reviews the presence of FES after a cosmetic procedure with STF.
Thomas L. Eberhardt; Karen G. Reed
2006-01-01
Southern yellow pine bark was obtained from an industrial source and subjected to grinding and classification operations to ultimately afford finely ground bark fractions for evaluation as plywood adhesive mix fillers. Specifically, by grinding in a laboratory blender, we were able to generate a bark fraction rich in periderm tissue with its interlocking spiculate...
Kim, Hyuk; Park, Kui Young; Choi, Sun Young; Koh, Hyun-Ju; Park, Sun-Young; Park, Won-Seok; Bae, Il-Hong
2014-01-01
Background Recent advances in hyaluronic acid (HA) fillers and radiofrequency (RF) devices have been made in the context of skin rejuvenation and cosmetic surgery. Moreover, combination regimens with both techniques are currently being developed. Objective The present study was designed to examine the clinical and histologic effects of a new needle that incorporates an RF device for HA injections. Methods A new intradermal needle RF device (INNOfill; Pacific Pharma, Korea) was assessed in the present study. In the animal arm, procollagen production was measured by using enzyme-linked immunosorbent assay, the filler volume was quantified by incorporating a dye with filler, and the filler distribution was assessed through the changes in tissue structure. In the human arm, the efficacy of the combination regimen was assessed by using the wrinkle severity rating scale (WSRS). Results In the animal study, RF treatment increased procollagen production in a time-dependent fashion. The total volume was significantly increased with the RF treatment when compared with the filler injections alone, and lasted for up to 7 weeks after treatment. Additionally, the filler distribution was reduced in animals treated with RF when compared with the untreated group. In the human study, the nasolabial folds of subjects treated with RF before filler injections exhibited a significantly greater change in the WSRS score from baseline when compared with the nasolabial folds treated with filler injections alone. Conclusion A new device incorporating RF treatment before HA filler injection may represent a biocompatible and long-lasting advance in skin rejuvenation. PMID:25143672
Tissue response to silicone rubber when used as a root canal filling.
Kasman, F G; Goldman, M
1977-04-01
To test the tissue compatibility of silicone rubber when it is used as a root canal filler, excess material was intentionally forced into the apical tissues in primates. The tissue response was one of general acceptance, with the usual response being fibrotic encapsulation. A low degree of inflammation was noted. Further studies are in progress.
Van Nieuwenhove, I; Tytgat, L; Ryx, M; Blondeel, P; Stillaert, F; Thienpont, H; Ottevaere, H; Dubruel, P; Van Vlierberghe, S
2017-11-01
There is a clear and urgent clinical need to develop soft tissue fillers that outperform the materials currently used for adipose tissue reconstruction. Recently, extensive research has been performed within this field of adipose tissue engineering as the commercially available products and the currently existing techniques are concomitant with several disadvantages. Commercial products are highly expensive and associated with an imposing need for repeated injections. Lipofilling or free fat transfer has an unpredictable outcome with respect to cell survival and potential resorption of the fat grafts. Therefore, researchers are predominantly investigating two challenging adipose tissue engineering strategies: in situ injectable materials and porous 3D printed scaffolds. The present work provides an overview of current research encompassing synthetic, biopolymer-based and extracellular matrix-derived materials with a clear focus on emerging fabrication technologies and developments realized throughout the last decade. Moreover, clinical relevance of the most promising materials will be discussed, together with potential concerns associated with their application in the clinic. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Aydemir Sezer, Umran; Ozturk, Kevser; Aru, Basak; Yanıkkaya Demirel, Gulderen; Sezer, Serdar; Bozkurt, Mehmet Recep
2017-01-01
Regeneration of nerve, which has limited ability to undergo self-healing, is one of the most challenging areas in the field of tissue engineering. Regarding materials used in neuroregeneration, there is a recent trend toward electrically conductive materials. It has been emphasized that the capacity of conductive materials to regenerate such tissue having limited self-healing ability improves their clinical utility. However, there have been concerns about the safety of materials or fillers used for conductance due to their lack of degradability. Here, we attempt to use poly(Ɛ-caprolactone) (PCL) matrix consisting of varying proportions of zero valent zinc nanoparticles (Zn NPs) via electrospinning. These conductive, biodegradable, and bioactive materials efficiently promoted neuroglial cell proliferation depending on the amount of Zn NPs present in the PCL matrix. Chemical characterizations indicated that the incorporated Zn NPs do not interact with the PCL matrix chemically and that the Zn NPs improved the tensile properties of the PCL matrix. All composites exhibited linear conductivity under in vitro conditions. In vitro cell culture studies were performed to determine the cytotoxicity and proliferative efficiency of materials containing different proportions of Zn NPs. The results were obtained to explore new conductive fillers that can promote tissue regeneration.
Chan, Ka Man Carmen; Li, Randolph H.; Chapman, Joseph W.; Trac, Eric M.; Kobler, James B.; Zeitels, Steven M.; Langer, Robert; Karajanagi, Sandeep S.
2014-01-01
Particle size, stiffness and surface functionality are important in determining the injection site, safety and efficacy of injectable soft-tissue fillers. Methods to produce soft injectable biomaterials with controlled particle characteristics are therefore desirable. Here we report a method based on suspension photopolymerization and semi-interpenetrating network (semi-IPN) to synthesize soft, functionalizable, spherical hydrogel microparticles (MP) of independently tunable size and stiffness. MP were prepared using acrylated forms of polyethylene glycol (PEG), gelatin and hyaluronic acid. Semi-IPN MP of PEG-diacrylate and PEG were used to study the effect of process parameters on particle characteristics. The process parameters were systematically varied to produce MP with size ranging from 115 to 515 μm and stiffness ranging from 190 to 1600 Pa. In vitro studies showed that the MP thus prepared were cytocompatible. The ratio and identity of the polymers used to make the semi-IPN MP were varied to control their stiffness and to introduce amine groups for potential functionalization. Slow-release polymeric particles loaded with Rhodamine or dexamethasone were incorporated in the MP as a proof-of-principle of drug incorporation and release from the MP. This work has implications in preparing injectable biomaterials of natural or synthetic polymers for applications as soft-tissue fillers. PMID:24561708
Desire for penile girth enhancement and the effects of the self-injection of hyaluronic Acid gel.
Coskuner, Enis Rauf; Canter, Halil Ibrahim
2012-07-01
Penile girth enhancement is a controversial subject but demands for enhancement are increasing steadily. Although various fillers have been widely used for soft tissue augmentation, there is no reliable material for this particular situation. Here we report a case of an acute hypersensitivity reaction in a man after his first self-injection of a filler material, which, he claimed, was hyaluronic acid gel for penile girth enhancement and glans penis augmentation.
Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.
van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina
2017-12-13
Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com
Chitosan nanocomposites based on distinct inorganic fillers for biomedical applications
Moura, Duarte; Mano, João F.; Paiva, Maria C.; Alves, Natália M.
2016-01-01
Abstract Chitosan (CHI), a biocompatible and biodegradable polysaccharide with the ability to provide a non-protein matrix for tissue growth, is considered to be an ideal material in the biomedical field. However, the lack of good mechanical properties limits its applications. In order to overcome this drawback, CHI has been combined with different polymers and fillers, leading to a variety of chitosan-based nanocomposites. The extensive research on CHI nanocomposites as well as their main biomedical applications are reviewed in this paper. An overview of the different fillers and assembly techniques available to produce CHI nanocomposites is presented. Finally, the properties of such nanocomposites are discussed with particular focus on bone regeneration, drug delivery, wound healing and biosensing applications. PMID:27877909
Trends in the design of nerve guidance channels in peripheral nerve tissue engineering.
Chiono, Valeria; Tonda-Turo, Chiara
2015-08-01
The current trend of peripheral nerve tissue engineering is the design of advanced nerve guidance channels (NGCs) acting as physical guidance for regeneration of nerves across lesions. NGCs should present multifunctional properties aiming to direct the sprouting of axons from the proximal nerve end, to concentrate growth factors secreted by the injured nerve ends, and to reduce the ingrowth of scar tissue into the injury site. A critical aspect in the design of NGCs is conferring them the ability to provide topographic, chemotactic and haptotactic cues that lead to functional nerve regeneration thus increasing the axon growth rate and avoiding or minimizing end-organ (e.g. muscle) atrophy. The present work reviews the recent state of the art in NGCs engineering and defines the external guide and internal fillers structural and compositional requirements that should be satisfied to improve nerve regeneration, especially in the case of large gaps (>2 cm). Techniques for NGCs fabrication were described highlighting the innovative approaches direct to enhance the regeneration of axon stumps compared to current clinical treatments. Furthermore, the possibility to apply stem cells as internal cues to the NGCs was discussed focusing on scaffold properties necessary to ensure cell survival. Finally, the optimized features for NGCs design were summarized showing as multifunctional cues are needed to produce NGCs having improved results in clinics. Copyright © 2015 Elsevier Ltd. All rights reserved.
... options include laser treatments, high-tech light devices, chemical peels, dermabrasion, liposuction, lifts, vein treatments, soft-tissue fillers, neuromodulators (Botox) and hair restoration among others. The first thing to remember ...
Desire for Penile Girth Enhancement and the Effects of the Self-Injection of Hyaluronic Acid Gel
Coskuner, Enis Rauf; Canter, Halil Ibrahim
2012-01-01
Penile girth enhancement is a controversial subject but demands for enhancement are increasing steadily. Although various fillers have been widely used for soft tissue augmentation, there is no reliable material for this particular situation. Here we report a case of an acute hypersensitivity reaction in a man after his first self-injection of a filler material, which, he claimed, was hyaluronic acid gel for penile girth enhancement and glans penis augmentation. PMID:23112518
Borgquist, Ola; Gustafsson, Lotta; Ingemansson, Richard; Malmsjö, Malin
2010-06-01
Negative pressure wound therapy (NPWT) results in 2 types of tissue deformation, macrodeformation (ie, wound contraction) and microdeformation (ie, the interaction of tissue and dressing on a microscopic level). These effects have been delineated for one type of wound filler, foam, but not for gauze. The mechanical deformation initiates a signaling cascade which ultimately leads to wound healing. The aim of the present study was to examine the effect of gauze and foam on macro- and microdeformation during treatment with negative pressure. An in vivo porcine peripheral wound model was used. NPWT was applied for 72 hours at 0, -75, and -125 mm Hg, using either foam or gauze as wound filler. The mechanical effects of NPWT were examined by measuring the wound surface area reduction and by histologic analysis of the wound bed tissue. Similar degrees of wound contraction (macrodeformation) were seen during NPWT regardless if foam or gauze was used. After negative pressure had been discontinued, the wound stayed contracted. There was no difference in wound contraction between -75 and -125 mm Hg. Biopsies of the wound bed revealed a repeating pattern of wound surface undulations and small tissue blebs ("tissue mushrooms") were pulled into the pores of the foam dressing and the spaces between the threads in the gauze dressing (microdeformation). This pattern was obvious in wounds treated both with foam and gauze, at atmospheric pressure (0 mm Hg) as well as at subatmospheric pressures (-75 and -125 mm Hg). The degrees of micro- and macrodeformation of the wound bed are similar after NPWT regardless if foam or gauze is used as wound filler.
Complications of Minimally Invasive Cosmetic Procedures: Prevention and Management
Levy, Lauren L; Emer, Jason J
2012-01-01
Over the past decade, facial rejuvenation procedures to circumvent traditional surgery have become increasingly popular. Office-based, minimally invasive procedures can promote a youthful appearance with minimal downtime and low risk of complications. Injectable botulinum toxin (BoNT), soft-tissue fillers, and chemical peels are among the most popular non-invasive rejuvenation procedures, and each has unique applications for improving facial aesthetics. Despite the simplicity and reliability of office-based procedures, complications can occur even with an astute and experienced injector. The goal of any procedure is to perform it properly and safely; thus, early recognition of complications when they do occur is paramount in dictating prevention of long-term sequelae. The most common complications from BoNT and soft-tissue filler injection are bruising, erythema and pain. With chemical peels, it is not uncommon to have erythema, irritation and burning. Fortunately, these side effects are normally transient and have simple remedies. More serious complications include muscle paralysis from BoNT, granuloma formation from soft-tissue filler placement and scarring from chemical peels. Thankfully, these complications are rare and can be avoided with excellent procedure technique, knowledge of facial anatomy, proper patient selection, and appropriate pre- and post-skin care. This article reviews complications of office-based, minimally invasive procedures, with emphasis on prevention and management. Practitioners providing these treatments should be well versed in this subject matter in order to deliver the highest quality care. PMID:23060707
Treatment of Soft Tissue Filler Complications: Expert Consensus Recommendations.
Urdiales-Gálvez, Fernando; Delgado, Nuria Escoda; Figueiredo, Vitor; Lajo-Plaza, José V; Mira, Mar; Moreno, Antonio; Ortíz-Martí, Francisco; Del Rio-Reyes, Rosa; Romero-Álvarez, Nazaret; Del Cueto, Sofía Ruiz; Segurado, María A; Rebenaque, Cristina Villanueva
2018-04-01
Dermal fillers have been increasingly used in minimally invasive facial esthetic procedures. This widespread use has led to a rise in reports of associated complications. The aim of this expert consensus report is to describe potential adverse events associated with dermal fillers and to provide guidance on their treatment and avoidance. A multidisciplinary group of experts in esthetic treatments convened to discuss the management of the complications associated with dermal fillers use. A search was performed for English, French, and Spanish language articles in MEDLINE, the Cochrane Database, and Google Scholar using the search terms "complications" OR "soft filler complications" OR "injectable complications" AND "dermal fillers" AND "Therapy". An initial document was drafted by the Coordinating Committee, and it was reviewed and modified by the experts, until a final text was agreed upon and validated. The panel addressed consensus recommendations about the classification of filler complications according to the time of onset and about the clinical management of different complications including bruising, swelling, edema, infections, lumps and bumps, skin discoloration, and biofilm formation. Special attention was paid to vascular compromise and retinal artery occlusion. Clinicians should be fully aware of the signs and symptoms related to complications and be prepared to confidently treat them. Establishing action protocols for emergencies, with agents readily available in the office, would reduce the severity of adverse outcomes associated with injection of hyaluronic acid fillers in the cosmetic setting. This document seeks to lay down a set of recommendations and to identify key issues that may be useful for clinicians who are starting to use dermal fillers. Additionally, this document provides a better understanding about the diagnoses and management of complications if they do occur. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Laser fluorescence of dentin caries covered with a novel nano-filled sealant.
Braun, Andreas; Beisel, Christian; Brede, Olivier; Krause, Felix
2013-01-01
The aim of the present study was to assess the possibility to measure caries-induced laser fluorescence underneath a novel nano-filled fissure sealant. Sixty freshly extracted human teeth with occlusal dentine carious lesions were horizontally divided, exposing the respective lesion. Teeth were randomly assigned to three groups: (I) white fissure sealant with filler particles (Fissurit F, Voco), (II) clear fissure sealant without filler particles (Fissurit, Voco) and (III) novel experimental fissure sealant with nano-filler particles (Voco). Starting with a sealant thickness of 3 mm, laser fluorescence measurements (DIAGNOdent, KaVo) were performed after finishing the sealant surfaces with polishing papers, reducing the material at intervals of 0.5 mm until the sealant was removed completely. Evaluating a thickness of 0.5 mm, both the clear (83 % of the baseline fluorescence after fine grit polishing) and the white sealant (25 %) did not allow to measure baseline fluorescence (p < 0.05) with no fluorescence reduction in the experimental sealant group (p > 0.05). With increasing sealer thickness, fluorescence was influenced even by the experimental material (89 % of the baseline value at 1 mm). However, by using the experimental material, statistically significant higher fluorescence values than those for the other materials under study (p < 0.05) were obtained. Thicker sealant layers and coarse grit polishing caused a decrease of laser fluorescence in all groups (p < 0.05). Employing the experimental nano-filled sealant, laser fluorescence measurements for caries detection can be performed through thicker sealant layers compared to conventional sealant materials. Thus, it might be possible to use this material to assess a caries progression underneath the sealant and administer an appropriate therapy in due time.
Kohn-Polster, Caroline; Bhatnagar, Divya; Woloszyn, Derek J.; Richtmyer, Matthew; Starke, Annett; Springwald, Alexandra H.; Franz, Sandra; Schulz-Siegmund, Michaela; Kaplan, Hilton M.; Kohn, Joachim; Hacker, Michael C.
2017-01-01
Toward the next generation of nerve guidance conduits (NGCs), novel biomaterials and functionalization concepts are required to address clinical demands in peripheral nerve regeneration (PNR). As a biological polymer with bioactive motifs, gelatinous peptides are promising building blocks. In combination with an anhydride-containing oligomer, a dual-component hydrogel system (cGEL) was established. First, hollow cGEL tubes were fabricated by a continuous dosing and templating process. Conduits were characterized concerning their mechanical strength, in vitro and in vivo degradation and biocompatibility. Second, cGEL was reformulated as injectable shear thinning filler for established NGCs, here tyrosine-derived polycarbonate-based braided conduits. Thereby, the formulation contained the small molecule LM11A-31. The biofunctionalized cGEL filler was assessed regarding building block integration, mechanical properties, in vitro cytotoxicity, and growth permissive effects on human adipose tissue-derived stem cells. A positive in vitro evaluation motivated further application of the filler material in a sciatic nerve defect. Compared to the empty conduit and pristine cGEL, the functionalization performed superior, though the autologous nerve graft remains the gold standard. In conclusion, LM11A-31 functionalized cGEL filler with extracellular matrix (ECM)-like characteristics and specific biochemical cues holds great potential to support PNR. PMID:28531139
Kohn-Polster, Caroline; Bhatnagar, Divya; Woloszyn, Derek J; Richtmyer, Matthew; Starke, Annett; Springwald, Alexandra H; Franz, Sandra; Schulz-Siegmund, Michaela; Kaplan, Hilton M; Kohn, Joachim; Hacker, Michael C
2017-05-21
Toward the next generation of nerve guidance conduits (NGCs), novel biomaterials and functionalization concepts are required to address clinical demands in peripheral nerve regeneration (PNR). As a biological polymer with bioactive motifs, gelatinous peptides are promising building blocks. In combination with an anhydride-containing oligomer, a dual-component hydrogel system (cGEL) was established. First, hollow cGEL tubes were fabricated by a continuous dosing and templating process. Conduits were characterized concerning their mechanical strength, in vitro and in vivo degradation and biocompatibility. Second, cGEL was reformulated as injectable shear thinning filler for established NGCs, here tyrosine-derived polycarbonate-based braided conduits. Thereby, the formulation contained the small molecule LM11A-31. The biofunctionalized cGEL filler was assessed regarding building block integration, mechanical properties, in vitro cytotoxicity, and growth permissive effects on human adipose tissue-derived stem cells. A positive in vitro evaluation motivated further application of the filler material in a sciatic nerve defect. Compared to the empty conduit and pristine cGEL, the functionalization performed superior, though the autologous nerve graft remains the gold standard. In conclusion, LM11A-31 functionalized cGEL filler with extracellular matrix (ECM)-like characteristics and specific biochemical cues holds great potential to support PNR.
Studies on crosslinked hydroxyapatite-polyethylene composite as a bone-analogue material
NASA Astrophysics Data System (ADS)
Smolko, E.; Romero, G.
2007-08-01
The paper examines the use of different types of polymeric matrix composites in hard-tissue replacement applications. The composite samples were prepared with hydroxyapatite (HA) powder and polyethylenes of different densities. The raw material was first compounded in the extruder and the resulting composite pre-forms were compression molded into desired plates and irradiated with different doses. Modulus of elasticity in tension, tensile strength, tensile fracture strain, elongation at break and gel content were obtained for all composites. Ceramic filler distribution was investigated under scanning electron microscopy (SEM). With HA incorporated in the samples an increase in the values of Young's Modulus, (stiffness) was observed, while elongation at break decreased with the amount of filler, showing increase of brittleness. Tensile strengths at yield and at break decreased with the filler content for LD and MDPE and stayed constant for HDPE.
Alam, Murad; Levy, Ross; Pajvani, Urvi; Pavjani, Urvi; Ramierez, James A; Guitart, Joan; Veen, Heather; Gladstone, Hayes B
2006-03-01
Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings. 2006 Wiley-Liss, Inc.
Dermal Filler Injection: A Novel Approach for Limiting Infarct Expansion
Ryan, Liam P.; Matsuzaki, Kanji; Noma, Mio; Jackson, Benjamin M.; Eperjesi, Thomas J.; Plappert, Theodore J.; St. John-Sutton, Martin G.; Gorman, Joseph H.; Gorman, Robert C.
2011-01-01
Background Early infarct expansion after coronary occlusion compromises contractile function in perfused myocardial regions and promotes adverse long-term left ventricular (LV) remodeling. We hypothesized that injection of a tissue-expanding dermal filler material into a myocardial infarction (MI) would attenuate infarct expansion and limit LV remodeling. Methods Fifteen sheep were subjected to an anteroapical MI involving approximately 20% of the LV followed by the injection of 1.3 mL of a calcium hydroxyapatite–based dermal filler into the infarct. Real-time three-dimensional echocardiography was performed at baseline, 30 minutes after MI, and 15 minutes after injection to assess infarct expansion. Sixteen additional sheep were subjected to the same infarction and followed echocardiographically and hemodynamically for 4 weeks after MI to assess chronic remodeling. Eight animals had injection with dermal filler as described above immediately after MI, and 8 animals were injected with an equal amount of saline solution. Results All animals exhibited infarct expansion soon after coronary occlusion. The regional ejection fraction of the apex became negative after infarction, consistent with systolic dyskinesia. Injection of the dermal filler converted the apical wall motion from dyskinetic to akinetic and resulted immediately in significant decreases in global, regional, and segmental LV volumes. Chronically, relative to saline control, dermal filler injection significantly reduced LV end-systolic volume (62.2 ± 3.6 mL versus 44.5 ± 3.9 mL; p < 0.05) and improved global ejection fraction (0.295 ± 0.016 versus 0.373 ± 0.017; p < 0.05) at 4 weeks after infarction. Conclusions Injection of an acellular dermal filler into an MI immediately after coronary occlusion reduces early infarct expansion and limits chronic LV remodeling. PMID:19101288
Polyacrylamide hydrogel injection for breast augmentation: Another injectable failure
Wang, Zhenxiang; Li, Shirong; Wang, Lingli; Zhang, Shu; Jiang, Yan; Chen, Jinping; Luo, Donglin
2012-01-01
Summary Background Increasing complications of polyacrylamide hydrogel (PAAG) augmentation mammoplasty, such as chronic persistent infection, have recently caught the attention of both the medical field and the general public. Material/Methods A total of 96 patients with severe chronic infection following PAAG augmentation mammoplasty were treated in the present study including 63 cases with infection confined to the breast and 33 with systemic infection. Endoscopy and surgery were performed to completely remove the materials and clear the infected tissues followed by drug-irrigation and vacuum-assisted closure for several days. Results In patients with severe infection there were large amounts of PAAG, fibers and infiltration of numerous neutrophils and macrophages. The infection-inducing materials were extensively dispersed in the mammary and subcutaneous tissues, pectoral fascia and intermuscular space. In addition, there was scattered distribution of PAAG materials in the armpit, chest wall and abdominal wall, which were mixed with necrotic tissues and surrounded by lymphocytes, giant cells, macrophages and other inflammatory cells, forming chronic granulomatous and fibrous lesions. Infection was controlled following surgical intervention. No residual infectious foci or recurrent infections were noted among these patients. Although the severe infection did not result in mastectomy, patients had breast atrophy and various degrees of deformation. Conclusions Chronic infection following PAAG augmentation mammaplasty usually causes systemic infection and other devastating adverse reactions. This study confirms PAAG augmentation mammaplasty is another failed attempt. More attention should be paid to the injection of large doses of liquid filler. PMID:22648256
NASA Astrophysics Data System (ADS)
Damodaran, Vani; Rao, Suresh Ranga; Vasa, Nilesh J.
2016-08-01
In this paper, a study of in-house built optical coherence tomography (OCT) system with a wavelength of 840 nm for imaging of dental caries, progress in demineralisation and cavity restoration is presented. The caries when imaged with the 840 nm OCT system showed minute demineralisation in the order of 5 μm. The OCT system was also proposed to study the growth of lesion and this was demonstrated by artificially inducing caries with a demineralisation solution of pH 4.8. The progress of carious lesion to a depth of about 50-60 μm after 60 hours of demineralisation was clearly observed with the 840 nm OCT system. The tooth samples were subjected to accelerated demineralisation condition at pH of approximately 2.3 to study the adverse effects and the onset of cavity formation was clearly observed. The restoration of cavity was also studied by employing different restorative materials (filled and unfilled). In the case of restoration without filler material (unfilled), the restoration boundaries were clearly observed. Overall, results were comparable with that of the widely used 1310 nm OCT system. In the case of restoration with filler material, the 1310 nm OCT imaging displayed better imaging capacity due to lower scattering than 840 nm imaging.
Imaging review of lipomatous musculoskeletal lesions
Burt, Ashley M.; Huang, Brady K.
2017-01-01
Lipomatous lesions are common musculoskeletal lesions that can arise within the soft tissues, bone, neurovascular structures, and synovium. The majority of these lesions are benign, and many of the benign lesions can be diagnosed by radiologic evaluation. However, radiologic differences between benign and malignant lipomatous lesions may be subtle and pathologic correlation is often needed. The use of sonography, computed tomography (CT), and magnetic resonance imaging (MRI) is useful not only in portraying fat within the lesion, but also for evaluating the presence and extent of soft tissue components. Lipomas make up most soft tissue lipomatous lesions, but careful evaluation must be performed to distinguish these lesions from a low-grade liposarcoma. In addition to the imaging appearance, the location of the lesion and the patient demographics can be utilized to help diagnose other soft tissue lipomatous lesions, such as elastofibroma dorsi, angiolipoma, lipoblastoma, and hibernoma. Osseous lipomatous lesions such as a parosteal lipoma and intraosseous lipoma occur less commonly as their soft tissue counterpart, but are also benign. Neurovascular and synovial lipomatous lesions are much rarer lesions but demonstrate more classic radiologic findings, particularly on MRI. A review of the clinical, radiologic, and pathologic characteristics of these lesions is presented. PMID:28474576
Successful Management of Infected Facial Filler with Brucella.
Alshaer, Zahra; Alsaadi, Yazeed; Mrad, Mohamed Amir
2018-06-11
The widespread desire to maintain youth and beauty with minimally invasive procedures made the use of soft tissue fillers an attractive option to correct numerous aesthetic problems. However, many complications have emerged recently especially with the use of non-FDA-approved permanent materials. In this case report, we are demonstrating the effective management of a patient with Brucella isolated from a facial abscess at the site of prior permanent filler injection done 17 years ago. A 56-year-old woman presented complaining of painful swelling of the right cheek after a failed trial of filler evacuation and intralesional corticosteroid injection. The patient was interviewed carefully, and physical examination was performed, followed by culture and imaging. The patient had a facial abscess that was complicated by parotid infiltration by Brucella. Eventually she was managed successfully by anti-Brucella antibiotics for 6 months with no further complaints. A review of causative organisms in the literature along with recommendations for management is discussed. Permanent fillers have shown many complications that can occur even years after injection. Therefore, physicians should be careful when using permanent fillers and should restrict their use to certain situations. Moreover, rare infections must be kept in mind and careful history, including travel history and animal contact, needs to be considered particularly in the unusual scenarios. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Soft tissue augmentation with artecoll: 10-year history, indications, techniques, and complications.
Lemperle, Gottfried; Romano, James J; Busso, Mariano
2003-06-01
Most of the biologic filler materials that increase the thickness of the corium in a wrinkle line are phagocytosed within a certain time. Therefore, a lasting effect can only be achieved with nonresorbable synthetic substances. Artefill consists of 20 volume percent microspheres of polymethyl-methacrylate and 80 volume percent of bovine collagen. Beneath the crease, the microspheres with their exceptional surface smoothness stimulate fibroblasts to encapsulate each individual one of the 6-million microspheres contained in 1 mL of Artefill. Collagen is merely a carrier substance that prevents the microspheres from agglomerating during tissue ingrowth. The 20 volume percent of microspheres in Artefill provides the scaffold for the 80% volume of connective tissue deposition, a complete replacement of the injected collagen. The filler material beneath a crease acts like a splint and prevents the possibility of its further folding, thereby allowing the diminished thickness of the corium in a crease to recover. This recovery process is well known even in older patients with facial paralysis or after a stroke, whose facial wrinkles and furrows on the paralyzed side disappear over time.
Tissue-Simulating Gel For Medical Research
NASA Technical Reports Server (NTRS)
Companion, John A.
1992-01-01
Nonhardening, translucent gel more nearly simulates soft human or animal tissue. Modified to be softer or harder by altering proportions of ingredients. Fillers added to change electrical, mechanical, heat-conducting, or sound-conducting/scattering properties. Molded to any desired shape and has sufficient mechanical strength to maintain shape without supporting shell. Because of its thermal stability, gel especially useful for investigation of hyperthermia as treatment for cancer.
Tozaki, Mitsuhiro; Isobe, Sachiko; Sakamoto, Masaaki
2012-10-01
We evaluated the diagnostic performance of elastography and tissue quantification using acoustic radiation force impulse (ARFI) technology for differential diagnosis of breast masses. There were 161 mass lesions. First, lesion correspondence on ARFI elastographic images to those on the B-mode images was evaluated: no findings on ARFI images (pattern 1), lesions that were bright inside (pattern 2), lesions that were dark inside (pattern 4), lesions that contained both bright and dark areas (pattern 3). In addition, pattern 4 was subdivided into 4a (dark area same as B-mode lesion) and 4b (dark area larger than lesion). Next, shear wave velocity (SWV) was measured using virtual touch tissue quantification. There were 13 pattern 1 lesions and five pattern 2 lesions; all of these lesions were benign, whereas all pattern 4b lesions (n = 43) were malignant. When the value of 3.59 m/s was chosen as the cutoff value, the combination of elastography and tissue quantification showed 91 % (83-91) sensitivity, 93 % (65-70) specificity, and 92 % (148-161) accuracy. The combination of elastography and tissue quantification is thought to be a promising ultrasound technique for differential diagnosis of breast-mass lesions.
Häcker, Axel; Peters, Kristina; Knoll, Thomas; Marlinghaus, Ernst; Alken, Peter; Jenne, Jürgen W; Michel, Maurice Stephan
2006-11-01
To investigate strategies to achieve confluent kidney-tissue ablation by high-intensity focused ultrasound (HIFU). Our model of the perfused ex-vivo porcine kidney was used. Tissue ablation was performed with an experimental HIFU device (Storz Medical, Kreuzlingen, Switzerland). Lesion-to-lesion interaction was investigated by varying the lesion distance (5 to 2.5 mm), generator power (300, 280, and 260 W), cooling time (10, 20, and 30 seconds), and exposure time (4, 3, and 2 seconds). The lesion rows were analyzed grossly and by histologic examination (hematoxylin-eosin and nicotinamide adenine dinucleotide staining). It was possible to achieve complete homogeneous ablation of a clinically relevant tissue volume but only by meticulous adjustment of the exposure parameters. Minimal changes in these parameters caused changes in lesion formation with holes within the lesions and lesion-to-lesion interaction. Our preliminary results show that when using this new device, HIFU can ablate a large tissue volume homogeneously in perfused ex-vivo porcine tissue under standardized conditions with meticulous adjustment of exposure parameters. Further investigations in vivo are necessary to test whether large tissue volumes can be ablated completely and reliably despite the influence of physiologic tissue and organ movement.
Detection and three-dimensional visualization of lesion models using sonoelastography
NASA Astrophysics Data System (ADS)
Taylor, Lawrence S.; Gaborski, Thomas R.; Strang, John G.; Rubens, Deborah; Parker, Kevin J.
2002-04-01
Sonoelastography is a vibration Doppler technique for imaging the relative elasticity of tissues. Detectability of hard lesions of various sizes has previously been demonstrated in tissue phantoms by our group. Because real tissue differs from phantom material, the injection of formaldehyde in fresh liver tissue is being used as an in-vitro lesion model. Pieces of fresh calf liver were embedded in an agar gel then injected with a bolus of 37% formaldehyde to create a stiff lesion. Two and three-dimensional sonoelastography and b-mode images were acquired. The lesions were visible in each sonoelastography image as a region of reduced vibration. After imaging, lesions were dissected and measured for size and volume. One 0.4 cc bolus injection of formaldehyde created a lesion with a volume of 10.3 cc in the sonoelastography image compared to 9.3 cc using fluid displacement of the dissected lesion. A 0.33 cc injection of formaldehyde lesion created a volume of 5 cc in the sonoelastography image compared to 4.4 cc using fluid displacement. Sonoelastography imaging techniques for imaging hard lesions in phantoms can be successfully extended to imaging formaldehyde induced lesions in real tissue.
Current Concepts in the Use of Small-Particle Hyaluronic Acid.
Bertucci, Vince; Lynde, Carrie B
2015-11-01
Soft-tissue augmentation with hyaluronic acid (HA) fillers has become one of the most popular cosmetic procedures performed. HA fillers represent safe and commonly used fillers. Several different HA fillers are available. The differences lie in the manufacturing process, allowing for tailored uses. A small-particle HA with lidocaine (SP-HAL; Restylane Silk; Galderma, Uppsala, Sweden) was approved by the US Food and Drug Administration in June 2014 but has been available for many years in Canada as Restylane Fine Lines and in Europe as Restylane Vital. Relevant articles were reviewed relating to the composition, effectiveness, and safety of SP-HAL. We also discuss the author's extensive clinical experience in the use of this product in Canada. SP-HAL has demonstrated proven benefits for lip fullness, augmentation, and treatment of perioral rhytides. Although off-label in the United States, SP-HAL is also well suited for the treatment of superficial fine lines, including periorbital, forehead, marionette, and smile lines. In addition, it has also been used in the tear trough region. A novel application for SP-HAL includes use as a skinbooster with intradermal micropuncture. In this technique, small aliquots of product are injected so as to gradually rejuvenate the skin in areas such as the face and hands. Side effects of SP-HAL were generally transient and mild. The most common side effects were swelling, tenderness, bruising, pain, and redness. SP-HAL is an effective and safe HA filler with varied clinical uses.
Managing Carious Lesions: Consensus Recommendations on Carious Tissue Removal.
Schwendicke, F; Frencken, J E; Bjørndal, L; Maltz, M; Manton, D J; Ricketts, D; Van Landuyt, K; Banerjee, A; Campus, G; Doméjean, S; Fontana, M; Leal, S; Lo, E; Machiulskiene, V; Schulte, A; Splieth, C; Zandona, A F; Innes, N P T
2016-05-01
The International Caries Consensus Collaboration undertook a consensus process and here presents clinical recommendations for carious tissue removal and managing cavitated carious lesions, including restoration, based on texture of demineralized dentine. Dentists should manage the disease dental caries and control activity of existing cavitated lesions to preserve hard tissues and retain teeth long-term. Entering the restorative cycle should be avoided as far as possible. Controlling the disease in cavitated carious lesions should be attempted using methods which are aimed at biofilm removal or control first. Only when cavitated carious lesions either are noncleansable or can no longer be sealed are restorative interventions indicated. When a restoration is indicated, the priorities are as follows: preserving healthy and remineralizable tissue, achieving a restorative seal, maintaining pulpal health, and maximizing restoration success. Carious tissue is removed purely to create conditions for long-lasting restorations. Bacterially contaminated or demineralized tissues close to the pulp do not need to be removed. In deeper lesions in teeth with sensible (vital) pulps, preserving pulpal health should be prioritized, while in shallow or moderately deep lesions, restoration longevity becomes more important. For teeth with shallow or moderately deep cavitated lesions, carious tissue removal is performed according toselective removal to firm dentine.In deep cavitated lesions in primary or permanent teeth,selective removal to soft dentineshould be performed, although in permanent teeth,stepwise removalis an option. The evidence and, therefore, these recommendations support less invasive carious lesion management, delaying entry to, and slowing down, the restorative cycle by preserving tooth tissue and retaining teeth long-term. © International & American Associations for Dental Research 2016.
Shen, Shan; Szameitat, André J; Sterr, Annette
2008-07-01
Detection of infarct lesions using traditional segmentation methods is always problematic due to intensity similarity between lesions and normal tissues, so that multispectral MRI modalities were often employed for this purpose. However, the high costs of MRI scan and the severity of patient conditions restrict the collection of multiple images. Therefore, in this paper, a new 3-D automatic lesion detection approach was proposed, which required only a single type of anatomical MRI scan. It was developed on a theory that, when lesions were present, the voxel-intensity-based segmentation and the spatial-location-based tissue distribution should be inconsistent in the regions of lesions. The degree of this inconsistency was calculated, which indicated the likelihood of tissue abnormality. Lesions were identified when the inconsistency exceeded a defined threshold. In this approach, the intensity-based segmentation was implemented by the conventional fuzzy c-mean (FCM) algorithm, while the spatial location of tissues was provided by prior tissue probability maps. The use of simulated MRI lesions allowed us to quantitatively evaluate the performance of the proposed method, as the size and location of lesions were prespecified. The results showed that our method effectively detected lesions with 40-80% signal reduction compared to normal tissues (similarity index > 0.7). The capability of the proposed method in practice was also demonstrated on real infarct lesions from 15 stroke patients, where the lesions detected were in broad agreement with true lesions. Furthermore, a comparison to a statistical segmentation approach presented in the literature suggested that our 3-D lesion detection approach was more reliable. Future work will focus on adapting the current method to multiple sclerosis lesion detection.
Thermal modeling of lesion growth with radiofrequency ablation devices
Chang, Isaac A; Nguyen, Uyen D
2004-01-01
Background Temperature is a frequently used parameter to describe the predicted size of lesions computed by computational models. In many cases, however, temperature correlates poorly with lesion size. Although many studies have been conducted to characterize the relationship between time-temperature exposure of tissue heating to cell damage, to date these relationships have not been employed in a finite element model. Methods We present an axisymmetric two-dimensional finite element model that calculates cell damage in tissues and compare lesion sizes using common tissue damage and iso-temperature contour definitions. The model accounts for both temperature-dependent changes in the electrical conductivity of tissue as well as tissue damage-dependent changes in local tissue perfusion. The data is validated using excised porcine liver tissues. Results The data demonstrate the size of thermal lesions is grossly overestimated when calculated using traditional temperature isocontours of 42°C and 47°C. The computational model results predicted lesion dimensions that were within 5% of the experimental measurements. Conclusion When modeling radiofrequency ablation problems, temperature isotherms may not be representative of actual tissue damage patterns. PMID:15298708
Brandy, Dominic A
2003-03-01
As the human face ages, there is a depletion of fat that occurs in the submalar region. Various techniques such as fat transfers, fillers, alloplastic implants, and composite rhytidectomies have been used to augment this area in the past. To describe a technique that augments the submalar areas during facelift surgery without the use of fat transfer, fillers, alloplastic implants, or a risky composite technique. An oval is scribed over the depressed submalar areas preoperatively. During facelift surgery, a fusiform area is scribed over the SMAS. This fusiform is scribed so that the medial end is directed at the center of the submalar depression, and the lateral end is toward the posterior earlobe. A defect is created within the lateral aspect of the fusiform, but not the medial portion. The fusiform is subsequently closed with a 2-0 Ethibond suture using three horizontal mattress sutures and two interrupted sutures. Upon closure of this defect, SMAS, subSMAS, and subcutaneous tissue overlying the SMAS are recruited into the submalar defect by the simple phenomenon of dog-ear formation. Additionally, there is a component of frank elevation of the tissues inferior to the medial aspect of the fusiform and submalar space. The aforementioned technique has been performed on 123 patients over 7 years and has resulted in consistently good improvement in the submalar space. The procedure is not difficult to learn, and good results can be achieved with initial cases. The learning curve was not found to be steep, with good results being achieved quickly. Depression of the submalar space plays a significant role in creating an aged face. In the past, various fillers and/or alloplastic implants have been used to augment this region. A low-risk method is described that mobilizes SMAS, subSMAS, and subcutaneous tissues into the submalar space through the phenomenon of dog-ear formation after fusiform closure.
Non Lipomatous Benign Lesions Mimicking Soft-tissue Sarcomas: A Pictorial Essay
CORAN, ALESSANDRO; ORSATTI, GIOVANNA; CRIMÌ, FILIPPO; RASTRELLI, MARCO; DI MAGGIO, ANTONIO; PONZONI, ALBERTO; ATTAR, SHADY; STRAMARE, ROBERTO
2018-01-01
The incidental finding of soft tissue masses is a challenge for the radiologist. Benign and malignant lesions can be differentiated relying on patient history, symptoms and mostly with the help of imaging. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) become fundamental in order to distinguish these lesions but the radiologist needs to know the main characteristics of benign soft tissue masses and sarcomas. Herein, we present a pictorial review of lesions mimicking soft tissue sarcomas features. PMID:29475903
Adipose‑derived stem cells and hyaluronic acid based gel compatibility, studied in vitro.
Guo, Jiayan; Guo, Shu; Wang, Yuxin; Yu, Yanqiu
2017-10-01
Minimally invasive aesthetic and cosmetic procedures have increased in popularity. Injectable dermal fillers provide soft tissue augmentation, improve facial rejuvenation and wrinkles, and correct tissue defects. To investigate the use of adipose‑derived stem cells integrated with a hyaluronic acid based gel as a dermal filler, the present study used cytotoxicity studies, proliferation studies, adipogenic and osteogenic differentiation, apoptosis assays and scanning electron microscopy. Although hyaluronic acid induced low levels of apoptosis in adipose‑derived stem cells, its significantly promoted proliferation of adipose‑derived stem cells. Hyaluronic acid demonstrates little toxicity against adipose‑derived stem cells. Adipose‑derived stem cells were able to differentiate into adipocytes and osteoblasts. Furthermore, scanning electron microscopy revealed that adipose‑derived stem cells maintained intact structures on the surface of hyaluronic acid as well as in it, and demonstrated abundant cell attachments. The present study demonstrated the compatibility of adipose‑derived stem cells and hyaluronic acid based gels in vitro.
Maietta, Saverio; Russo, Teresa; De Santis, Roberto; Ronca, Dante; Riccardi, Filomena; Martorelli, Massimo; Gloria, Antonio
2018-01-01
Experimental/theoretical analyses have already been performed on poly(ε-caprolactone) (PCL) loaded with organic–inorganic fillers (PCL/TiO2 and PCL/ZrO2) to find a correlation between the results from the small punch test and Young’s modulus of the materials. PCL loaded with Ti2 (PCL = 12, TiO2 = 88 wt %) and Zr2 (PCL = 12, ZrO2 = 88 wt %) hybrid fillers showed better performances than those obtained for the other particle composition. In this context, the aim of current research is to provide further insight into the mechanical properties of PCL loaded with sol–gel-synthesized organic–inorganic hybrid fillers for bone tissue engineering. For this reason, theoretical analyses were performed by the finite element method. The results from the small punch test and Young’s modulus of the materials were newly correlated. The obtained values of Young’s modulus (193 MPa for PCL, 378 MPa for PCL/Ti2 and 415 MPa for PCL/Zr2) were higher than those obtained from a previous theoretical modelling (144 MPa for PCL, 282 MPa for PCL/Ti2 and 310 MPa for PCL/Zr2). This correlation will be an important step for the evaluation of Young’s modulus, starting from the small punch test data. PMID:29466299
Maietta, Saverio; Russo, Teresa; Santis, Roberto De; Ronca, Dante; Riccardi, Filomena; Catauro, Michelina; Martorelli, Massimo; Gloria, Antonio
2018-02-21
Experimental/theoretical analyses have already been performed on poly(ε-caprolactone) (PCL) loaded with organic-inorganic fillers (PCL/TiO₂ and PCL/ZrO₂) to find a correlation between the results from the small punch test and Young's modulus of the materials. PCL loaded with Ti2 (PCL = 12, TiO₂ = 88 wt %) and Zr2 (PCL = 12, ZrO₂ = 88 wt %) hybrid fillers showed better performances than those obtained for the other particle composition. In this context, the aim of current research is to provide further insight into the mechanical properties of PCL loaded with sol-gel-synthesized organic-inorganic hybrid fillers for bone tissue engineering. For this reason, theoretical analyses were performed by the finite element method. The results from the small punch test and Young's modulus of the materials were newly correlated. The obtained values of Young's modulus (193 MPa for PCL, 378 MPa for PCL/Ti2 and 415 MPa for PCL/Zr2) were higher than those obtained from a previous theoretical modelling (144 MPa for PCL, 282 MPa for PCL/Ti2 and 310 MPa for PCL/Zr2). This correlation will be an important step for the evaluation of Young's modulus, starting from the small punch test data.
de Jesus, Luciano Henrique; de Campos Hildebrand, Laura; Martins, Manoela Domingues; da Rosa, Francinne Miranda; Danilevicz, Chris Krebs; Sant’Ana Filho, Manoel
2015-01-01
Polymethylmethacrylate (PMMA) has been widely used in the correction of wrinkles because of its long-lasting cosmetic improvements. However, side effects and complications may occur, and its clinical appearance on the oral mucosa can be similar to that of inflammatory or neoplastic disease. The aim of this research was to compare the clinical and histopathologic responses to PMMA injected by two different methods. Twenty-two rats received an injection of PMMA using the tunneling technique (gold standard), with subcutaneous deposition of the filler in the face, or a variation of the technique with transcutaneous submucosal deposition of the filler in the cheek. The tissue reaction was analyzed clinically every 24 hours during the first week, then once a week for the following 3 months. Histologic evaluation was based on the local inflammatory response to the filler. No clinical changes were observed during the initial evaluation period (0–14 days). After 14 days, only the submucosal group showed extra-oral enlargement (n=4, 18.2%). Histopathologic analysis revealed nodule formation in four animals (18.2%) in the submucosal group, with no nodules observed in the subcutaneous group. The data obtained in this study demonstrate that the technique used to deliver the filler may influence the risk of adverse reactions. PMID:26346665
Amrita; Arora, Aditya; Sharma, Poonam; Katti, Dhirendra S
2015-06-05
Porous hydrogels have been explored for bone tissue engineering; however their poor mechanical properties make them less suitable as bone graft substitutes. Since incorporation of fillers is a well-accepted method for improving mechanical properties of hydrogels, in this work pullulan hydrogels were reinforced with nano-crystalline hydroxyapatite (nHAp) (5 wt% nHAp in hydrogel) and poly(3-hydroxybutyrate) (PHB) fibers (3 wt% fibers in hydrogel) containing nHAp (3 wt% nHAp in fibers). Addition of these fillers to pullulan hydrogel improved compressive modulus of the scaffold by 10 fold. However, the hydrophilicity of pullulan did not support adhesion and spreading of cells. To overcome this limitation, porous composite scaffolds were modified using a double diffusion method that enabled deposition of hydroxyapatite on pore walls. This method resulted in rapid and uniform coating of HAp throughout the three-dimensional scaffolds which not only rendered them osteoconductive in vitro but also led to an improvement in their compressive modulus. These results demonstrate the potential of mineralized pullulan-based composite scaffolds in non-load bearing bone tissue engineering. Copyright © 2015 Elsevier Ltd. All rights reserved.
Optical probe with light fluctuation protection
Da Silva, Luiz B.; Chase, Charles L.
2003-11-11
An optical probe for tissue identification includes an elongated body. Optical fibers are located within the elongated body for transmitting light to and from the tissue. Light fluctuation protection is associated with the optical fibers. In one embodiment the light fluctuation protection includes a reflective coating on the optical fibers to reduce stray light. In another embodiment the light fluctuation protection includes a filler with very high absorption located within the elongated body between the optical fibers.
Are midsagittal tissue bridges predictive of outcome after cervical spinal cord injury?
Huber, Eveline; Lachappelle, Patrice; Sutter, Reto; Curt, Armin; Freund, Patrick
2017-05-01
T 2 -weighted scans provided data on the extent and dynamics of neuronal tissue damage and midsagittal tissue bridges at the epicenter of traumatic cervical spinal cord lesions in 24 subacute tetraplegic patients. At 1 month postinjury, smaller lesion area and midsagittal tissue bridges identified those patients with lower extremity evoked potentials and better clinical recovery. Wider midsagittal tissue bridges and smaller lesions at 1 month post-injury were associated with neurological and functional recovery at 1-year follow-up. Neuroimaging biomarkers of lesion size and midsagittal tissue bridges are potential outcome predictors and patient stratifiers in both subacute and chronic clinical trials. Ann Neurol 2017;81:740-748. © 2017 American Neurological Association.
Eranki, Avinash; Farr, Navid; Partanen, Ari; V. Sharma, Karun; Chen, Hong; Rossi, Christopher T.; Kothapalli, Satya V. V. N.; Oetgen, Matthew; Kim, AeRang; H. Negussie, Ayele; Woods, David; J. Wood, Bradford; C. W. Kim, Peter; S. Yarmolenko, Pavel
2017-01-01
Purpose High intensity focused ultrasound (HIFU) is a non-invasive therapeutic technique that can thermally ablate tumors. Boiling histotripsy (BH) is a HIFU approach that can emulsify tissue in a few milliseconds. Lesion volume and temperature effects for different BH sonication parameters are currently not well characterized. In this work, lesion volume, temperature distribution, and area of lethal thermal dose were characterized for varying BH sonication parameters in tissue-mimicking phantoms (TMP) and demonstrated in ex vivo tissues. Methods The following BH sonication parameters were varied using a clinical MR-HIFU system (Sonalleve V2, Philips, Vantaa, Finland): acoustic power, number of cycles/pulse, total sonication time, and pulse repetition frequency (PRF). A 3×3×3 pattern was sonicated inside TMP’s and ex vivo tissues. Post sonication, lesion volumes were quantified using 3D ultrasonography and temperature and thermal dose distributions were analyzed offline. Ex vivo tissues were sectioned and stained with H&E post sonication to assess tissue damage. Results Significant increase in lesion volume was observed while increasing the number of cycles/pulse and PRF. Other sonication parameters had no significant effect on lesion volume. Temperature full width at half maximum at the end of sonication increased significantly with all parameters except total sonication time. Positive correlation was also found between lethal thermal dose and lesion volume for all parameters except number of cycles/pulse. Gross pathology of ex vivo tissues post sonication displayed either completely or partially damaged tissue at the focal region. Surrounding tissues presented sharp boundaries, with little or no structural damage to adjacent critical structures such as bile duct and nerves. Conclusion Our characterization of effects of HIFU sonication parameters on the resulting lesion demonstrates the ability to control lesion morphologic and thermal characteristics with a clinical MR-HIFU system in TMP’s and ex vivo tissues. We demonstrate that this system can produce spatially precise lesions in both phantoms and ex vivo tissues. The results provide guidance on a preliminary set of BH sonication parameters for this system, with a potential to facilitate BH translation to the clinic. PMID:28301597
Image-based modeling and characterization of RF ablation lesions in cardiac arrhythmia therapy
NASA Astrophysics Data System (ADS)
Linte, Cristian A.; Camp, Jon J.; Rettmann, Maryam E.; Holmes, David R.; Robb, Richard A.
2013-03-01
In spite of significant efforts to enhance guidance for catheter navigation, limited research has been conducted to consider the changes that occur in the tissue during ablation as means to provide useful feedback on the progression of therapy delivery. We propose a technique to visualize lesion progression and monitor the effects of the RF energy delivery using a surrogate thermal ablation model. The model incorporates both physical and physiological tissue parameters, and uses heat transfer principles to estimate temperature distribution in the tissue and geometry of the generated lesion in near real time. The ablation model has been calibrated and evaluated using ex vivo beef muscle tissue in a clinically relevant ablation protocol. To validate the model, the predicted temperature distribution was assessed against that measured directly using fiberoptic temperature probes inserted in the tissue. Moreover, the model-predicted lesions were compared to the lesions observed in the post-ablation digital images. Results showed an agreement within 5°C between the model-predicted and experimentally measured tissue temperatures, as well as comparable predicted and observed lesion characteristics and geometry. These results suggest that the proposed technique is capable of providing reasonably accurate and sufficiently fast representations of the created RF ablation lesions, to generate lesion maps in near real time. These maps can be used to guide the placement of successive lesions to ensure continuous and enduring suppression of the arrhythmic pathway.
Hydroxyapatite/collagen bone-like nanocomposite.
Kikuchi, Masanori
2013-01-01
Our group has succeeded to synthesize material with bone-like nanostructure and bone-like inorganic and organic composition via self-organization mechanism between them using simultaneous titration method under controlled pH and temperature. The hydroxyapatite/collagen (HAp/Col) bone-like nanocomposite completely incorporated into bone remodeling process to be substituted by new bone. Cells cultured on the HAp/Col revealed very interesting reactions. Osteoblast-like MG63 cells showed upregulation of alkaline phosphatase >3 times greater than MG63 cells cultured on tissue culture polystyrene (TCPS). MG63 cells 3-dimensionally cultured in a "HAp/Col sponge," a porous HAp/Col having sponge-like viscoelasticity, accumulated calcium phosphate nodules on extracellular matrices they secreted. Bone marrow cells co-cultured with osteoblasts on HAp/Col differentiated to osteoclasts without differentiation supplements. This phenomenon is not found in cells cultured on hydroxyapatite ceramics and TCPS, and rarely in cells cultured on dentin. These results suggest that HAp/Col is a good candidate for tissue engineering of bone as well as bone filler. In a clinical test as a bone filler, the HAp/Col sponge was significantly better than porous β-tricalcium phosphate. The HAp/Col sponge has been approved by the Japanese government and will be used as greatly needed bone filler in patients. In addition to the above, HAp/Col coating on titanium revealed higher osteo-conductivity than HAp-coated titanium and bare titanium and improved direct bonding between titanium and newly formed bone. The HAp/Col coating may be used for metal devices requiring osseointegration.
Urdiales-Gálvez, Fernando; Delgado, Nuria Escoda; Figueiredo, Vitor; Lajo-Plaza, José V; Mira, Mar; Ortíz-Martí, Francisco; Del Rio-Reyes, Rosa; Romero-Álvarez, Nazaret; Del Cueto, Sofía Ruiz; Segurado, María A; Rebenaque, Cristina Villanueva
2017-06-01
The use of dermal fillers in minimally invasive facial aesthetic procedures has become increasingly popular of late, yet as the indications and the number of procedures performed increase, the number of complications is also likely to increase. Paying special attention to specific patient characteristics and to the technique used can do much to avoid these complications. Indeed, a well-trained physician can also minimize the impact of such problems when they do occur. A multidisciplinary group of experts in aesthetic treatments reviewed the main factors associated with the complications that arise when using dermal fillers. A search of English, French and Spanish language articles in PubMed was performed using the terms "complications" OR "soft filler complications" OR "injectable complications" AND "dermal fillers". An initial document was drafted that reflected the complications identified and recommendations as to how they should be handled. This document was then reviewed and modified by the expert panel, until a final text was agreed upon and validated. The panel addressed consensus recommendations about the preparation, the procedure and the post-procedural care. The panel considered it crucial to obtain an accurate medical history to prevent potential complications. An additional clinical assessment, including standardized photography, is also crucial to evaluate the outcomes and prevent potential complications. Furthermore, the state of the operating theatre, the patient's health status and the preparation of the skin are critical to prevent superficial soft tissue infections. Finally, selecting the appropriate technique, based on the physician's experience, as well as the characteristics of the patient and filler, helps to ensure successful outcomes and limits the complications. This consensus document provides key elements to help clinicians who are starting to use dermal fillers to employ standard procedures and to understand how best to prevent potential complications of the treatment. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Meyer, Julie L.; Rodgers, John M.; Dillard, Brian A.; Paul, Valerie J.; Teplitski, Max
2016-01-01
Dark Spot Syndrome (DSS) is one of the most common diseases of boulder corals in the Caribbean. It presents as sunken brown lesions in coral tissue, which can spread quickly over coral colonies. With this study, we tested the hypothesis that similar to other coral diseases, DSS is a dysbiosis characterized by global shifts in the coral microbiome. Because Black Band Disease (BBD) was sometimes found following DSS lesions, we also tested the hypothesis that DSS is a precursor of BBD. To track disease initiation and progression 24 coral colonies were tagged. Of them five Orbicella annularis corals and three O. faveolata corals exhibited DSS lesions at tagging. Microbiota of lesions and apparently healthy tissues from DSS-affected corals over the course of 18 months were collected. Final visual assessment showed that five of eight corals incurred substantial tissue loss while two corals remained stable and one appeared to recover from DSS lesions. Illumina sequencing of the V6 region of bacterial 16S rRNA genes demonstrated no significant differences in bacterial community composition associated with healthy tissue or DSS lesions. The epimicrobiomes of both healthy tissue and DSS lesions contained high relative abundances of Operational Taxonomic Units assigned to Halomonas, an unclassified gammaproteobacterial genus, Moritella, an unclassified Rhodobacteraceae genus, Renibacterium, Pseudomonas, and Acinetobacter. The relative abundance of bacterial taxa was not significantly different between samples when grouped by tissue type (healthy tissue vs. DSS lesion), coral species, collection month, or the overall outcome of DSS-affected corals (substantial tissue loss vs. stable/recovered). Two of the tagged corals with substantial tissue loss also developed BBD during the 18-month sampling period. The bacterial community of the BBD layer was distinct from both healthy tissue and DSS lesions, with high relative abundances of the presumed BBD pathogen Roseofilum reptotaenium and an unclassified Bacteroidales genus, similar to previous results. Roseofilum was detected in all samples from this study, with the highest relative abundance in healthy tissue from DSS-affected corals sampled in August, suggesting that while DSS is not a precursor to BBD, DSS-affected corals are in a weakened state and therefore more susceptible to additional infections. PMID:27375605
Photothermal lesions in soft tissue induced by optical fiber microheaters.
Pimentel-Domínguez, Reinher; Moreno-Álvarez, Paola; Hautefeuille, Mathieu; Chavarría, Anahí; Hernández-Cordero, Juan
2016-04-01
Photothermal therapy has shown to be a promising technique for local treatment of tumors. However, the main challenge for this technique is the availability of localized heat sources to minimize thermal damage in the surrounding healthy tissue. In this work, we demonstrate the use of optical fiber microheaters for inducing thermal lesions in soft tissue. The proposed devices incorporate carbon nanotubes or gold nanolayers on the tips of optical fibers for enhanced photothermal effects and heating of ex vivo biological tissues. We report preliminary results of small size photothermal lesions induced on mice liver tissues. The morphology of the resulting lesions shows that optical fiber microheaters may render useful for delivering highly localized heat for photothermal therapy.
Non Lipomatous Benign Lesions Mimicking Soft-tissue Sarcomas: A Pictorial Essay.
Coran, Alessandro; Orsatti, Giovanna; Crimì, Filippo; Rastrelli, Marco; DI Maggio, Antonio; Ponzoni, Alberto; Attar, Shady; Stramare, Roberto
2018-01-01
The incidental finding of soft tissue masses is a challenge for the radiologist. Benign and malignant lesions can be differentiated relying on patient history, symptoms and mostly with the help of imaging. Ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI) become fundamental in order to distinguish these lesions but the radiologist needs to know the main characteristics of benign soft tissue masses and sarcomas. Herein, we present a pictorial review of lesions mimicking soft tissue sarcomas features. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
NASA Astrophysics Data System (ADS)
Freidank, Sebastian; Vogel, Alfred; Anderson, Richard R.; Birngruber, Reginald; Linz, Norbert
2017-02-01
For ametropic eyes, LASIK is a common surgical procedure to correct the refractive error. However, the correction of hyperopia is more difficult than that of myopia because the increase of the central corneal curvature by excimer ablation is only possible by intrastromal tissue removal within a ring-like zone in the corneal periphery. For high hyperopia, the ring-shaped indentation leads to problems with the stability and reproducibility of the correction due to epithelial regrowth. Recently, it was shown that the correction of hyperopia can be achieved by implanting intracorneal inlays into a laser-dissected intrastromal pocket. In this paper we demonstrate the feasibility of a new approach in which a transparent, and biocompatible liquid filler material is injected into a laser-dissected corneal pocket, and the refractive change is monitored via OCT. This technique allows for a precise and adjustable change of the corneal curvature. Precise cutting of the intrastromal pocket was achieved by focusing UV laser picosecond pulses from a microchip laser system into the cornea. After laser dissection, the transparent filler material was injected into the pocket. The increase of the refractive power by filler injection was evaluated by taking OCT images from the cornea. With this novel technique, it is possible to precisely correct hyperopia of up to 10 diopters. An astigmatism correction is also possible by using ellipsoidal intrastromal pockets.
de Maio, Maurício; Wu, Woffles T L; Goodman, Greg J; Monheit, Gary
2017-09-01
This third article of a three-part series addresses techniques and recommendations for aesthetic treatment of the lower face. The lower face is considered an advanced area for facial aesthetic treatment. In this region, soft-tissue fillers play a more important role than neuromodulators and should be used first to provide structure and support before neuromodulators are considered for treatment of dynamic lines. Treatment of the lip, perioral region, and chin, in addition to maintaining balance of the lower face with the face overall, is challenging. Procedures on the lip should avoid overcorrection while respecting the projection of the lips on the profile view and the ratio of lip size to chin. The chin is often neglected, but reshaping the jawline can provide dramatic improvement in facial aesthetics. Both profile and anterior views are critical in assessment and treatment of the lower face. Finally, rejuvenation of the neck region requires fillers for structural support of the chin and jawline and neuromodulators for treatment of the masseter and platysma.
Sacroplasty for symptomatic sacral hemangioma: a novel treatment approach. A case report.
Agarwal, V; Sreedher, G; Weiss, K R; Hughes, M A
2013-06-01
Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications.
Sacroplasty for Symptomatic Sacral Hemangioma: A Novel Treatment Approach
Agarwal, V.; Sreedher, G.; Weiss, K.R.; Hughes, M.A.
2013-01-01
Summary Painful vertebral body hemangiomas have been successfully treated with vertebroplasty and kyphoplasty. Sacral hemangiomas are uncommon and as such painful sacral hemangiomas are rare entities. We report what we believe is only the second successful treatment of a painful sacral hemangioma with CT-guided sacroplasty. A 56-year-old woman with a history of right-sided total hip arthroplasty and lipoma excision presented to her orthopedic surgeon with persistent right-sided low back pain which radiated into her buttock and right groin and hindered her ability to walk and perform her activities of daily living. MRIs of the thoracic spine, lumbar spine and pelvis showed numerous lesions with imaging characteristics consistent with multiple hemangiomas including a 2.2×2.1 cm lesion involving the right sacrum adjacent to the right S1 neural foramen. Conservative measures including rest, physical therapy, oral analgesics and right-sided sacroiliac joint steroid injection did not provide significant relief. Given her lack of improvement and the fact that her pain localized to the right sacrum, the patient underwent CT-guided sacroplasty for treatment of a painful right sacral hemangioma. Under CT fluoroscopic guidance, a 10 gauge introducer needle was advanced through the soft tissues of the back to the margin of the lesion. Biopsy was then performed and after appropriate preparation, cement was then introduced through the needle using a separate cement filler cannula. Appropriate filling of the right sacral hemangioma was visualized using intermittent CT fluoroscopy. After injection of approximately 2.5 cc of cement, it was felt that there was near complete filling of the right sacral hemangioma. With satisfactory achievement of cement filling, the procedure was terminated. Pathology from biopsy taken at the time of the procedure was consistent with hemangioma. Image-guided sacroplasty with well-defined endpoints is an effective, minimally invasive and safe procedure. Patients with painful sacral hemangiomas can be treated with this technique with no significant complications. PMID:23693051
Peñarrocha, María; Carrillo, Celia; Peñarrocha, Miguel; Peñarrocha, David; von Arx, Thomas; Vera, Francisco
2011-06-01
To compare the preoperative signs and symptoms with the histologic diagnosis and postoperative healing at 12 months for 178 periapical lesions. A total of 152 patients who had undergone periapical surgery from 2005 to 2008 were studied. The study included patients presenting with signs and symptoms before periapical surgery with a sufficient tissue sample (periapical lesion) for histologic analysis and a minimal follow-up of 12 months. The signs and symptoms present in the soft tissues at the initial examination were recorded. The histologic analysis established the diagnosis as granuloma, cyst, or scar tissue. The postoperative healing at 12 months was evaluated according to the criteria of von Arx and Kurt. Of the 152 patients, 147, with 178 periapical lesions, were included in the present study. No significant relationship was found between the preoperative signs and symptoms, lesion type, and evolution. However, scar tissues were asymptomatic in 78.1%, and 36.4% of granulomas were painful. Of the 8 cysts, 50% were asymptomatic and 50% caused pain. Fibrous scars created no soft tissue alterations in 68.7%. Granulomas had fistulized in 31.7%, and 75% of cysts had produced no alterations. The lesions with swelling had worse healing, and those with no soft tissue alterations had better postoperative healing. Chronic periapical lesions (granuloma, cyst, and scar tissue) are usually asymptomatic and do not create soft tissue alterations. However, they can deteriorate, producing pain and fistulization. Worse postoperative healing was observed for lesions with swelling, although the difference was not significant. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Automated tissue segmentation of MR brain images in the presence of white matter lesions.
Valverde, Sergi; Oliver, Arnau; Roura, Eloy; González-Villà, Sandra; Pareto, Deborah; Vilanova, Joan C; Ramió-Torrentà, Lluís; Rovira, Àlex; Lladó, Xavier
2017-01-01
Over the last few years, the increasing interest in brain tissue volume measurements on clinical settings has led to the development of a wide number of automated tissue segmentation methods. However, white matter lesions are known to reduce the performance of automated tissue segmentation methods, which requires manual annotation of the lesions and refilling them before segmentation, which is tedious and time-consuming. Here, we propose a new, fully automated T1-w/FLAIR tissue segmentation approach designed to deal with images in the presence of WM lesions. This approach integrates a robust partial volume tissue segmentation with WM outlier rejection and filling, combining intensity and probabilistic and morphological prior maps. We evaluate the performance of this method on the MRBrainS13 tissue segmentation challenge database, which contains images with vascular WM lesions, and also on a set of Multiple Sclerosis (MS) patient images. On both databases, we validate the performance of our method with other state-of-the-art techniques. On the MRBrainS13 data, the presented approach was at the time of submission the best ranked unsupervised intensity model method of the challenge (7th position) and clearly outperformed the other unsupervised pipelines such as FAST and SPM12. On MS data, the differences in tissue segmentation between the images segmented with our method and the same images where manual expert annotations were used to refill lesions on T1-w images before segmentation were lower or similar to the best state-of-the-art pipeline incorporating automated lesion segmentation and filling. Our results show that the proposed pipeline achieved very competitive results on both vascular and MS lesions. A public version of this approach is available to download for the neuro-imaging community. Copyright © 2016 Elsevier B.V. All rights reserved.
Chen, Chen; Weir, Michael D.; Cheng, Lei; Lin, Nancy; Lin-Gibson, Sheng; Chow, Laurence C.; Zhou, Xuedong; Xu, Hockin H. K.
2015-01-01
Objectives Recurrent caries at the margins is a primary reason for restoration failure. The objectives of this study were to develop bonding agent with the double benefits of antibacterial and remineralizing capabilities, to investigate the effects of NACP filler level and solution pH on Ca and P ion release from adhesive, and to examine the antibacterial and dentin bond properties. Methods Nanoparticles of amorphous calcium phosphate (NACP) and a quaternary ammonium monomer (dimethylaminododecyl methacrylate, DMADDM) were synthesized. Scotchbond Multi-Purpose (SBMP) primer and adhesive served as control. DMADDM was incorporated into primer and adhesive at 5% by mass. NACP was incorporated into adhesive at filler mass fractions of 10%, 20%, 30% and 40%. A dental plaque microcosm biofilm model was used to test the antibacterial bonding agents. Calcium (Ca) and phosphate (P) ion releases from the cured adhesive samples were measured vs. filler level and solution pH of 7, 5.5 and 4. Results Adding 5% DMADDM and 10–40% NACP into bonding agent, and water-aging for 28 days, did not affect dentin bond strength, compared to SBMP control at 1 day (p > 0.1). Adding DMADDM into bonding agent substantially decreased the biofilm metabolic activity and lactic acid production. Total microorganisms, total streptococci, and mutans streptococci were greatly reduced for bonding agents containing DMADDM. Increasing NACP filler level from 10% to 40% in adhesive increased the Ca and P ion release by an order of magnitude. Decreasing solution pH from 7 to 4 increased the ion release from adhesive by 6–10 folds. Significance Bonding agents containing antibacterial DMADDM and remineralizer NACP were formulated to have Ca and P ion release, which increased with NACP filler level from 10% to 40% in adhesive. NACP adhesive was “smart” and dramatically increased the ion release at cariogenic pH 4, when these ions would be most-needed to inhibit caries. Therefore, bonding agent containing DMADDM and NACP may be promising to inhibit biofilms and remineralize tooth lesions thereby increasing the restoration longevity. PMID:24954647
Chen, Chen; Weir, Michael D; Cheng, Lei; Lin, Nancy J; Lin-Gibson, Sheng; Chow, Laurence C; Zhou, Xuedong; Xu, Hockin H K
2014-08-01
Recurrent caries at the margins is a primary reason for restoration failure. The objectives of this study were to develop bonding agent with the double benefits of antibacterial and remineralizing capabilities, to investigate the effects of NACP filler level and solution pH on Ca and P ion release from adhesive, and to examine the antibacterial and dentin bond properties. Nanoparticles of amorphous calcium phosphate (NACP) and a quaternary ammonium monomer (dimethylaminododecyl methacrylate, DMADDM) were synthesized. Scotchbond Multi-Purpose (SBMP) primer and adhesive served as control. DMADDM was incorporated into primer and adhesive at 5% by mass. NACP was incorporated into adhesive at filler mass fractions of 10%, 20%, 30% and 40%. A dental plaque microcosm biofilm model was used to test the antibacterial bonding agents. Calcium (Ca) and phosphate (P) ion releases from the cured adhesive samples were measured vs. filler level and solution pH of 7, 5.5 and 4. Adding 5% DMADDM and 10-40% NACP into bonding agent, and water-aging for 28 days, did not affect dentin bond strength, compared to SBMP control at 1 day (p>0.1). Adding DMADDM into bonding agent substantially decreased the biofilm metabolic activity and lactic acid production. Total microorganisms, total streptococci, and mutans streptococci were greatly reduced for bonding agents containing DMADDM. Increasing NACP filler level from 10% to 40% in adhesive increased the Ca and P ion release by an order of magnitude. Decreasing solution pH from 7 to 4 increased the ion release from adhesive by 6-10 folds. Bonding agents containing antibacterial DMADDM and remineralizer NACP were formulated to have Ca and P ion release, which increased with NACP filler level from 10% to 40% in adhesive. NACP adhesive was "smart" and dramatically increased the ion release at cariogenic pH 4, when these ions would be most-needed to inhibit caries. Therefore, bonding agent containing DMADDM and NACP may be promising to inhibit biofilms and remineralize tooth lesions thereby increasing the restoration longevity. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Johansson, Johannes D; Eriksson, Ola; Wren, Joakim; Loyd, Dan; Wårdell, Karin
2006-09-01
Radio-frequency brain lesioning is a method for reducing e.g. symptoms of movement disorders. A small electrode is used to thermally coagulate malfunctioning tissue. Influence on lesion size from thermal and electric conductivity of the tissue, microvascular perfusion and preset electrode temperature was investigated using a finite-element model. Perfusion was modelled as an increased thermal conductivity in non-coagulated tissue. The parameters were analysed using a 2(4)-factorial design (n=16) and quadratic regression analysis (n=47). Increased thermal conductivity of the tissue increased lesion volume, while increased perfusion decreased it since coagulation creates a thermally insulating layer due to the cessation of blood perfusion. These effects were strengthened with increased preset temperature. The electric conductivity had negligible effect. Simulations were found realistic compared to in vivo experimental lesions.
Noninvasive Assessment of Early Dental Lesion Using a Dual-Contrast Photoacoustic Tomography
Cheng, Renxiang; Shao, Jiaojiao; Gao, Xiaoxiang; Tao, Chao; Ge, Jiuyu; Liu, Xiaojun
2016-01-01
Dental hard tissue lesions, including caries, cracked-tooth, etc., are the most prevalent diseases of people worldwide. Dental lesions and correlative diseases greatly decrease the life quality of patients throughout their lifetime. It is still hard to noninvasively detect these dental lesions in their early stages. Photoacoustic imaging is an emerging hybrid technology combining the high spatial resolution of ultrasound in deep tissue with the rich optical contrasts. In this study, a dual-contrast photoacoustic tomography is applied to detect the early dental lesions. One contrast, named B-mode, is related to the optical absorption. It is good at providing the sharp image about the morphological and macro-structural features of the teeth. Another contrast, named S-mode, is associated with the micro-structural and mechanical properties of the hard tissue. It is sensitive to the change of tissue properties induced by the early dental lesions. Experiments show that the comprehensive analysis of dual-contrast information can provide reliable information of the early dental lesions. Moreover, the imaging parameter of S-mode is device-independent and it could measure tissue properties quantitatively. We expect that the proposed scheme could be beneficial for improving safety, accuracy and sensitivity of the clinical diagnosis of the dental lesion. PMID:26902394
Noninvasive Assessment of Early Dental Lesion Using a Dual-Contrast Photoacoustic Tomography
NASA Astrophysics Data System (ADS)
Cheng, Renxiang; Shao, Jiaojiao; Gao, Xiaoxiang; Tao, Chao; Ge, Jiuyu; Liu, Xiaojun
2016-02-01
Dental hard tissue lesions, including caries, cracked-tooth, etc., are the most prevalent diseases of people worldwide. Dental lesions and correlative diseases greatly decrease the life quality of patients throughout their lifetime. It is still hard to noninvasively detect these dental lesions in their early stages. Photoacoustic imaging is an emerging hybrid technology combining the high spatial resolution of ultrasound in deep tissue with the rich optical contrasts. In this study, a dual-contrast photoacoustic tomography is applied to detect the early dental lesions. One contrast, named B-mode, is related to the optical absorption. It is good at providing the sharp image about the morphological and macro-structural features of the teeth. Another contrast, named S-mode, is associated with the micro-structural and mechanical properties of the hard tissue. It is sensitive to the change of tissue properties induced by the early dental lesions. Experiments show that the comprehensive analysis of dual-contrast information can provide reliable information of the early dental lesions. Moreover, the imaging parameter of S-mode is device-independent and it could measure tissue properties quantitatively. We expect that the proposed scheme could be beneficial for improving safety, accuracy and sensitivity of the clinical diagnosis of the dental lesion.
The role of tissue damage in whiplash associated disorders: Discussion paper 1
Bogduk, Nikolai; Ivancic, Paul C.; McLean, Samuel A.; Siegmund, Gunter P.; Winkelstein, Beth
2011-01-01
STUDY DESIGN Non-systematic review of cervical spine lesions in whiplash-associated disorders (WAD). OBJECTIVE To describe whiplash injury models in terms of basic and clinical science, to summarize what can and cannot be explained by injury models, and to highlight future research areas to better understand the role of tissue damage in WAD. SUMMARY OF BACKGROUND DATA The frequent lack of detectable tissue damage has raised questions about whether tissue damage is necessary for WAD and what role it plays in the clinical context of WAD. METHODS Non-systematic review. RESULTS Lesions of various tissues have been documented by numerous investigations conducted in animals, cadavers, healthy volunteers and patients. Most lesions are undetected by imaging techniques. For zygapophysial (facet) joints, lesions have been predicted by bioengineering studies and validated through animal studies; for zygapophysial joint pain, a valid diagnostic test and a proven treatment are available. Lesions of dorsal root ganglia, discs, ligaments, muscles and vertebral artery have been documented in biomechanical and autopsy studies, but no valid diagnostic test is available to assess their clinical relevance. The proportion of WAD patients in whom a persistent lesion is the major determinant of ongoing symptoms is unknown. Psychosocial factors, stress reactions and generalized hyperalgesia have also been shown to predict WAD outcomes. CONCLUSION There is evidence supporting a lesion-based model in WAD. Lack of macroscopically identifiable tissue damage does not rule out the presence of painful lesions. The best available evidence concerns zygapophysial joint pain. The clinical relevance of other lesions needs to be addressed by future research. PMID:22020601
Impact of radiofrequency ablation geometry on electrical conduction
NASA Astrophysics Data System (ADS)
Rivas, Rhiana N.; Lye, Theresa H.; Hendon, Christine P.
2018-02-01
The gold standard of current treatment for atrial fibrillation is radiofrequency ablation (RFA). Single RFA procedures have low long-term, single-procedure success rates, which can be attributed to factors including inability to measure and visualize lesion depth in real time and incomplete knowledge of how atrial fibrillation manifests and persists. One way to address this problem is to develop a heart model that accurately fits lesion dimensions and depth using OCT to extract structural information. Twenty-three lesions of varying transmurality in left and right swine atrial tissue have been imaged with a Thorlabs OCT system with 6.5-micron axial resolution and a custom Ultra High Resolution system with 2.5-micron axial resolution. The boundaries of the ablation lesions were identified by the appearance of the birefringence artifact to identify areas of un-ablated tissue, as well as by changes to depth penetration and structural features, including decreased contrast between the endocardium and myocardium and disappearance of collagen fibers within the ablation lesion. Using these features, the lateral positions of the lesion boundaries were identified. An algorithm that fit ellipses to the lesion contours modeled the ablation geometry in depth. Lesion dimensions and shape were confirmed by comparison with trichrome histological processing. Finite-element models were fitted with these parameters and electrophysiological simulations were run with the Continuity 6 package. Next steps include correlating lesion geometry to conduction velocity, and including further tissue complexity such as varying tissue composition and fiber orientation. Additional models of linear lesions with gaps and adjacent lesions created with non-perpendicular contact will be created. This work will provide insight into how lesion geometry, tissue composition, and fiber organization impact electrophysiological propagation.
Pathology of tissue loss (white syndrome) in Acropora sp. corals from the Central Pacific.
Work, Thierry M; Aeby, Greta S
2011-06-01
We performed histological examination of 69 samples of Acropora sp. manifesting different types of tissue loss (Acropora White Syndrome-AWS) from Hawaii, Johnston Atoll and American Samoa between 2002 and 2006. Gross lesions of tissue loss were observed and classified as diffuse acute, diffuse subacute, and focal to multifocal acute to subacute. Corals with acute tissue loss manifested microscopic evidence of necrosis sometimes associated with ciliates, helminths, fungi, algae, sponges, or cyanobacteria whereas those with subacute tissue loss manifested mainly wound repair. Gross lesions of AWS have multiple different changes at the microscopic level some of which involve various microorganisms and metazoa. Elucidating this disease will require, among other things, monitoring lesions over time to determine the pathogenesis of AWS and the potential role of tissue-associated microorganisms in the genesis of tissue loss. Attempts to experimentally induce AWS should include microscopic examination of tissues to ensure that potentially causative microorganisms associated with gross lesion are not overlooked. Published by Elsevier Inc.
Pathology of tissue loss (white syndrome) in Acropora sp. corals from the Central Pacific
Work, Thierry M.; Aeby, Greta S.
2011-01-01
We performed histological examination of 69 samples of Acropora sp. manifesting different types of tissue loss (Acropora White Syndrome-AWS) from Hawaii, Johnston Atoll and American Samoa between 2002 and 2006. Gross lesions of tissue loss were observed and classified as diffuse acute, diffuse subacute, and focal to multifocal acute to subacute. Corals with acute tissue loss manifested microscopic evidence of necrosis sometimes associated with ciliates, helminths, fungi, algae, sponges, or cyanobacteria whereas those with subacute tissue loss manifested mainly wound repair. Gross lesions of AWS have multiple different changes at the microscopic level some of which involve various microorganisms and metazoa. Elucidating this disease will require, among other things, monitoring lesions over time to determine the pathogenesis of AWS and the potential role of tissue-associated microorganisms in the genesis of tissue loss. Attempts to experimentally induce AWS should include microscopic examination of tissues to ensure that potentially causative microorganisms associated with gross lesion are not overlooked.
Huang, Ji-yan; Zhao, Hou-ming; Zhou, Hai-wen
2014-04-01
To construct a database and a tissue bank of oral mucosa precancerous lesions and to estimate the application values. Patients in the Yangtze delta suffering oral mucosa precancerous lesions were enrolled into this study. The patients' clinical data and samples of oral precancerous mucosa, salivary and blood were collected to create a tissue bank, based on which a database was constructed using Microsoft Access software, Brower/Server structure and ASP language. The tissue bank and database of oral mucosa precancerous lesions were successfully built. The procedure to harvest, store and transport the samples had been standardized. The database showed good interactive interface, convenient for data collection, query and share in the internet. We constructed the tissue bank and database of oral mucosa precancerous lesions for the first time, which not only help preserve the biological resource of oral mucosa precancerous lesions, but also provide enormous convenience in clinical work, researching and teaching. Supported by Research Fund of Science and Technology Committee of Shanghai Municipality (08ZR1416700).
NASA Astrophysics Data System (ADS)
Chang, Chun-Hung; Fried, Nathaniel M.
2016-02-01
Infrared lasers have been used in combination with applied cooling methods to preserve superficial skin layers during cosmetic surgery. Similarly, combined laser irradiation and tissue cooling may also allow development of minimally invasive laser therapies beyond dermatology. This study compares diffusing, side-firing, and radial delivery laser balloon catheter designs for creation of subsurface lesions in tissue, ex vivo, using a near-IR laser and applied contact cooling. An Ytterbium fiber laser with 1075 nm wavelength delivered energy through custom built 18 Fr (6-mm-OD) balloon catheters incorporating either 10-mm-long diffusing fiber tip, 90 degree side-firing fiber, or radial delivery cone mirror, through a central lumen. A chilled solution was flowed through a separate lumen into 9-mm-diameter balloon to keep probe cooled at 7°C. Porcine liver tissue samples were used as preliminary tissue model for immediate observation of thermal lesion creation. The diffusing fiber produced subsurface thermal lesions measuring 49.3 +/- 10.0 mm2 and preserved 0.8 +/- 0.1 mm of surface tissue. The side-firing fiber produced subsurface thermal lesions of 2.4 +/- 0.9 mm2 diameter and preserved 0.5 +/- 0.1 mm of surface tissue. The radial delivery probe assembly failed to produce subsurface thermal lesions, presumably due to the small effective spot diameter at the tissue surface, which limited optical penetration depth. Optimal laser power and irradiation time measured 15 W and 100 s for diffusing fiber and 1.4 W and 20 s, for side-firing fiber, respectively. Diffusing and side-firing laser balloon catheter designs provided subsurface thermal lesions in tissue. However, the divergent laser beam in both designs limited the ability to preserve a thicker layer of tissue surface. Further optimization of laser and cooling parameters may be necessary to preserve thicker surface tissue layers.
Samarawickrama, Chameen; Samanta, Ayan; Liszka, Aneta; Fagerholm, Per; Buznyk, Oleksiy; Griffith, May; Allan, Bruce
2018-05-01
To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations. A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect. Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases. An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.
Ocular Pain and Impending Blindness During Facial Cosmetic Injections: Is Your Office Prepared?
Prado, Giselle; Rodríguez-Feliz, Jose
2017-02-01
Soft tissue filler injections are the second most common non-surgical procedure performed by the plastic surgeon. Embolization of intravascular material after facial injection is a rare but terrifying outcome due to the high likelihood of long-term sequela such as blindness and cerebrovascular accident. The literature is replete with examples of permanent blindness caused by injection with autologous fat, soft tissue fillers such as hyaluronic acid, PLLA, calcium hydroxyl-apatite, and even corticosteroid suspensions. However, missing from the discussion is an effective treatment algorithm that can be quickly and safely followed by injecting physicians in the case of an intravascular injection with impending blindness. In this report, we present the case of a 64-year-old woman who suffered from blindness and hemiparesis after facial cosmetic injections performed by a family physician. We use this case to create awareness that this complication has become more common as the number of injectors and patients seeking these treatments have increased exponentially over the past few years. We share in this study our experience with the incorporation of a "blindness safety kit" in each of our offices to promptly initiate treatment in someone with embolization and impending blindness. The kit contains a step-by-step protocol to follow in the event of arterial embolization of filler material associated with ocular pain and impending loss of vision. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Coral disease physiology: the impact of Acroporid white syndrome on Symbiodinium
NASA Astrophysics Data System (ADS)
Roff, G.; Kvennefors, E. C. E.; Ulstrup, K. E.; Fine, M.; Hoegh-Guldberg, O.
2008-06-01
Acroporid white syndrome, a disease-like syndrome from the Great Barrier Reef, results from degenerative host tissue at lesion borders. Tissue preceding lesion borders appears visually healthy, but it is currently unclear whether the endosymbiotic zooxanthellae ( Symbiodinium) are physiologically impacted. Compared to healthy colonies, this study found no significant differences in symbiont density, mitotic index or chlorophyll a content in tissue bordering (0 cm), and 8 cm away from white syndrome lesions. Using chlorophyll a fluorescence techniques, the border tissue did not appear to be photosynthetically compromised, and Symbiodinium extracted from this area were photosynthetically competent. Transmission electron microscopy revealed extensive degeneration of host tissues surrounding symbionts in affected areas, however, Symbiodinium cells were structurally intact with no sign of in situ degradation. Collectively, these results suggest that Symbiodinium at white syndrome lesion borders exist in a dynamic intra-cellular state during active host tissue loss, yet remain physiologically uncompromised.
Kirov, Ivan I; Liu, Shu; Tal, Assaf; Wu, William E; Davitz, Matthew S; Babb, James S; Rusinek, Henry; Herbert, Joseph; Gonen, Oded
2017-08-01
Although MRI assessment of white matter lesions is essential for the clinical management of multiple sclerosis, the processes leading to the formation of lesions and underlying their subsequent MRI appearance are incompletely understood. We used proton MR spectroscopy to study the evolution of N-acetyl-aspartate (NAA), creatine (Cr), choline (Cho), and myo-inositol (mI) in pre-lesional tissue, persistent and transient new lesions, as well as in chronic lesions, and related the results to quantitative MRI measures of T1-hypointensity and T2-volume. Within 10 patients with relapsing-remitting course, there were 180 regions-of-interest consisting of up to seven semi-annual follow-ups of normal-appearing white matter (NAWM, n = 10), pre-lesional tissue giving rise to acute lesions which resolved (n = 3) or persisted (n = 3), and of moderately (n = 9) and severely hypointense (n = 6) chronic lesions. Compared with NAWM, pre-lesional tissue had higher Cr and Cho, while compared with lesions, pre-lesional tissue had higher NAA. Resolving acute lesions showed similar NAA levels pre- and post-formation, suggesting no long-term axonal damage. In chronic lesions, there was an increase in mI, suggesting accumulating astrogliosis. Lesion volume was a better predictor of axonal health than T1-hypointensity, with lesions larger than 1.5 cm 3 uniformly exhibiting very low (<4.5 millimolar) NAA concentrations. A positive correlation between longitudinal changes in Cho and in lesion volume in moderately hypointense lesions implied that lesion size is mediated by chronic inflammation. These and other results are integrated in a discussion on the steady-state metabolism of lesion evolution in multiple sclerosis, viewed in the context of conventional MRI measures. Hum Brain Mapp 38:4047-4063, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Li, S C; Liebling, M S; Haines, K A; Weiss, J E; Prann, A
2011-05-01
To evaluate the construct validity of 2 proposed measures (the Ultrasound Disease Activity [U-DA] and the Tissue Thickness Score [TTS]) for evaluating sonographic differences in juvenile localized scleroderma skin lesions. We conducted a retrospective review of juvenile localized scleroderma patients who had ultrasound scans of their skin lesions between October 2005 and February 2009. Imaged lesions were classified as active or inactive based upon clinical assessment. Lesions had to have been imaged within 1 month of a clinic visit or have the same clinical assessment during both the visit before and the visit after the scan. Two physicians scored the scans using the U-DA, which scores for differences in lesion echogenicity and vascularity compared with normal tissue. Tissue thickness differences were evaluated by percent differences and by using the TTS. Wilcoxon's rank sum test was performed to assess differences. We studied 52 scans from 21 patients, 32 scans of active skin lesions and 20 scans of inactive skin lesions. Features reported by clinicians as indicative of active disease included erythema, warmth, violaceous color, new lesion, expansion of lesion, and induration. The U-DA was significantly different between active and inactive skin lesions (P = 0.0010) with significant differences found for the parameters of total echogenicity, hypodermis echogenicity, and deep tissue layer vascularity (P = 0.0014, P = 0.0023, and P = 0.0374, respectively). No significant differences were found for tissue layer thickness or TTS. The U-DA may be a useful tool in the identification of localized scleroderma activity. Further study is needed to prospectively evaluate the validity, reliability, and sensitivity of this potential monitoring tool. Copyright © 2011 by the American College of Rheumatology.
Błochowiak, Katarzyna; Andrysiak, Piotr; Sidorowicz, Krzysztof; Witmanowski, Henryk; Hędzelek, Wiesław; Sokalski, Jerzy
2015-10-01
Benign neoplasms and hyperplastic tumorous lesions are common oral pathologies. These lesions require to be surgically removed by conventional surgery, laser, or electrosurgery. Surgical treatment aims at complete removal of pathological lesions and ensuring proper healing of the tissues to minimize the risk of lesion recurrence. To present possible applications of Er:YAG and CO2 lasers in removal of benign neoplasms and tumorous lesions developing on oral mucosa as well as to specify indications and limitations of these two methods. Temperature-induced injuries due to laser light application, possibility of post-operative histopathological evaluation of the removed tissue, efficacy of the cut and coagulation, healing process and completeness of laser surgeries give rise to our special concern. The main asset of the CO2 laser comparing to Er:YAG laser is an effective coagulation while thermal injury to the tissues is its limitation, especially with multiple passage of the beam and too high power applied. Er:YAG laser application does not exclude histopathological examination of the removed lesion tissue which is its advantage over CO2 laser. Still, insufficient coagulation is a limitation ofits use in the case of richly vascularized lesions.
Diffusion-weighted MR imaging: role in the differential diagnosis of breast lesions.
Altay, C; Balci, P; Altay, S; Karasu, S; Saydam, S; Canda, T; Dicle, O
2014-01-01
To evaluate the diagnostic value of magnetic resonance diffusion-weighted imaging (DWI) using apparent diffusion coefficient (ADC) values to the characterization of breast lesions and differentiation of benign and malignant lesions. Thirty-seven women (mean age, 38 years) with 37 enrolled in the study. DWI and ADC maps in the axial plane were obtained using a 1.5 Tesla MRI device. Mean ADC measurements were calculated among cysts, normal fibroglandular tissue, benign lesions and malignant lesions were evaluated. Out of 37 women, 4 had normally breast MRI findings. The diagnosis of remaining 33 patients with 37 breast lesions were as follows; malign lesions (n = 23), benign lesions (n = 10) and simple breast cyst (n = 4). The ADC values were as follows (in units of 10(-3) mm2/s): Normal fibroglandular tissue (range: 1.39-2.06; mean: 1.61 ± 0.23), benign breast lesions (range: 1.09-1.76; mean: 1.47 ± 0.25), cyts (range: 2.27-2.46, mean: 2.37 ± 0.07) and malignant breast lesions (range: 0.78-1.26, mean: 0.96 ± 0.25). The mean ADC obtained from malignant breast lesions was statistically different from that observed in benign solid lesions (p < < 0.01) and normal fibroglandular breast tissue (p < 0.01). Furthermore, the mean ADC values of benign breast lesions was not statistically different from cyst (p ≥ 0.01) and normal fibroglandular breast tissue (p ≥ 0.01). A ADC value of 1.1 x 10(-3) mm'/s as a treshold value provided differantiation for malign and benign lesions, with a sensitivity of 91.3% and a specificity of 85.7% compared with conventional breast MRI values. DWI with quantitative ADC measurements is a reliable tool for differentiation of benign and malignant breast lesions.
Detection of blunt, sharp force and gunshot lesions on burnt remains: a cautionary note.
Poppa, Pasquale; Porta, Davide; Gibelli, Daniele; Mazzucchi, Alessandra; Brandone, Alberto; Grandi, Marco; Cattaneo, Cristina
2011-09-01
The study of skin and bone lesions may give information concerning type and manner of production, but in burnt material modification of tissues by the high temperatures may considerably change the morphological characteristics of the lesions. This study aims at pointing out the effects of burning head of pigs with several types of lesions (blunt trauma, sharp force, and gunshot lesions) on soft tissues and bones, both from a morphological and chemical point of view. Results show that the charring process does not completely destroy signs of lesions on bones, which can often be recovered by cleaning bone surface from charred soft-tissue residues. Furthermore, neutron activation analysis test proved that antimony may be detectable also on gunshot entry wounds at the final stages of charring process.
New long-wavelength Nd:YAG laser at 1.44 micron: effect on brain.
Martiniuk, R; Bauer, J A; McKean, J D; Tulip, J; Mielke, B W
1989-02-01
A wavelength-shifted Nd:YAG laser, tuned to coincide with the infrared absorption peak of water at 1.44 microns, was used to make lesions in normal rabbit brain. A total of 48 lesions were made with power up to 20 W, with energy up to 40 joules, and with two different spot sizes. These lesions were compared to lesions made with 1.06 microns radiation from an Nd:YAG laser under identical operating conditions. Measurements of blood-brain barrier damage and width, depth, and volume of tissue affected were obtained 30 minutes after placement of the lesions. It was found that 1.44-microns lesions produced photoevaporative tissue loss at the highest intensities used. The layer of coagulated tissue remaining after photovaporization had a mean thickness of 0.6 mm irrespective of the volume of tissue removed. There was no photovaporization in the 1.06-microns lesions. In addition, the amount of peripheral edema per unit volume of tissue coagulated was approximately half at the 1.44-microns wavelength. These findings suggest that the 1.44-microns Nd:YAG laser may be a useful surgical instrument since it combines the photoevaporative effect of the CO2 laser while maintaining the advantages of the conventional Nd:YAG laser (quartz fiber delivery and effective hemostasis).
Rho, Nark Kyoung; Park, Je Young; Youn, Choon Shik; Lee, Soo-Keun; Kim, Hei Sung
2017-02-01
Quantitative measurements are important for objective evaluation of postprocedural outcomes. Three-dimensional (3D) imaging is known as an objective, accurate, and reliable system for quantifying the soft tissue dimensions of the face. To compare the preprocedural and acute postprocedural nasofrontal, nasofacial, nasolabial, and nasomental angles, early changes in the height and length of the nose, and nasal volume using a 3D surface imaging with a light-emitting diode. The 3D imaging analysis of 40 Korean women who underwent structured nonsurgical rhinoplasty was conducted. The 3D assessment was performed before, immediately after, 1 day, and 2 weeks after filler rhinoplasty with a Morpheus 3D scanner (Morpheus Co., Seoul, Korea). There were significant early changes in facial profile following nonsurgical rhinoplasty with a hyaluronic acid filler. An average increase of 6.03° in the nasofrontal angle, an increase of 3.79° in the nasolabial angle, increase of 0.88° in the nasomental angle, and a reduction of 0.83° in the nasofacial angle was observed at 2 weeks of follow-up. Increment in nasal volume and nose height was also found after 2 weeks. Side effects, such as hematoma, nodules, and skin necrosis, were not observed. The 3D surface imaging quantitatively demonstrated the early changes in facial profile after structured filler rhinoplasty. The study results describe significant acute spatial changes in nose shape following treatment.
Efficacy of a new filler-containing root coating material for dentin remineralization.
Okuyama, Katsushi; Kadowaki, Yoshitaka; Matsuda, Yasuhiro; Hashimoto, Naoki; Oki, Saiko; Yamamoto, Hiroko; Tamaki, Yukimichi; Sano, Hidehiko
2016-08-01
To evaluate a new root coating material containing surface pre-reacted glass-ionomer (S-PRG) filler for remineralization of demineralized dentin. The dentin was exposed on root surfaces of human third molars and demineralized by immersion in demineralization solution for 4 days. The demineralized dentin surface was divided into three areas. The center area was left untreated. The area on one side of the center area was coated with protective wax. The area on the other side was coated with one of four test materials: fluoride-containing S-PRG filler (PRG Barrier Coat: PR), fluoride-containing bonding agent (Bond Force: BF), fluoride-containing glass-ionomer cement as a positive control (Fuji IX EXTRA: EX), or non-fluoride-containing bonding agent as a negative control (Clearfil MegaBond: MB). The samples were stored in remineralization solution for 7 days, and then cut into two slices. The mineral changes, defined as variation in mineral loss between wax-coated area and the central untreated area, were measured in one slice by transversal microradiography. The fluoride concentration was measured in the other slice by µ-particle-induced gamma/X-ray emission. Seven thin specimens (0.25-mm thickness) of each test material were used to determine fluoride ion release from the materials over 21 days. The mineral changes were greatest for EX, followed by PR, with no difference between BF and MB (P> 0.05). Regarding the fluoride concentrations in dentin, there was no difference between EX and PR (P> 0.05). MB had the lowest value (P< 0.01). Fluoride release from EX was largest, followed by PR, with BF showing low fluoride release (P< 0.05). MB had no fluoride release. A new coating material with S-PRG filler can be applied in a thin layer on root dentin, which could be especially useful for hard-to-access lesions. This material remineralized demineralized root dentin and had fluoride diffusion characteristics similar to those of glass-ionomer cement in vitro.
Gross and microscopic pathology of lesions in Pocillopora spp. from the subtropical eastern Pacific.
Rodríguez-Villalobos, Jenny Carolina; Rocha-Olivares, Axayácatl; Work, Thierry Martin; Calderon-Aguilera, Luis Eduardo; Cáceres-Martínez, Jorge Abelardo
2014-07-01
Coral reefs are threatened by a variety of factors including diseases that have caused significant damage in some regions such as in the Caribbean. At present, no data are available on coral diseases in the Mexican Pacific where Pocillopora spp. is a dominant component of coral communities. Here, we describe gross and microscopic morphology of lesions found in pocilloporids at four sites in the Mexican Pacific. Corals were identified and their lesions photographed and quantified in the field. Tissue samples were collected from healthy and affected colonies for histopathology. We recorded seven species of pocilloporids at the study sites with Isla Isabel being the location with the highest coral diversity (H'=1.27). Lesions were present in 42% of the colonies and included discoloration (32%), predation-induced tissue loss (30%), unexplained tissue loss (3%) and overgrowth by sponges or algae (35%). The most affected species, P. damicornis (50%), was also one of the most common in the region. No species was more prone to a particular lesion, but there was a significant association between location and the presence of lesions. Northern Islas Marietas (61%) and Isla Isabel (41%) had the highest prevalence of lesions, followed by Manzanillo (37%) and Bahías de Huatulco (23%). Histological changes included atrophy of the surface body wall with depletion of zooxanthellae (91%) in corals with discoloration (bleaching). Ablation of tissue from mesoglea (18%) was also observed. Colonies with unexplained tissue loss showed atrophy and thinning of the epidermis (89%), characterized by cuboidal instead of pseudocolumnar cells normally found in healthy pseudocolumnar ciliated epithelium. Bacterial aggregates between the mesoglea and gastrodermis (11%) were very conspicuous in healthy and diseased corals. Lesions produced by fish bites and gastropods were associated with tissue atrophy (40%) and, in some cases, algal overgrowth near the lesion (20%). No infectious agents associated with cell pathology were detected microscopically. Bleaching and overgrowth by algae and sponges, as well as unexplained tissue loss, are common in Pocillopora. These lesions and anatomical changes warrant further study since their incidence is potentially indicative of reef degradation. Copyright © 2014 Elsevier Inc. All rights reserved.
Gross and microscopic pathology of lesions in Pocillopora spp. from the subtropical eastern Pacific
Rodríguez-Villalobos, Jenny Carolina; Rocha-Olivares, Axayácatl; Work, Thierry M.; Calderon-Aguilera, Luis Eduardo; Cáceres-Martínez, Jorge Abelardo
2014-01-01
Coral reefs are threatened by a variety of factors including diseases that have caused significant damage in some regions such as in the Caribbean. At present, no data are available on coral diseases in the Mexican Pacific where Pocillopora spp. is a dominant component of coral communities. Here, we describe gross and microscopic morphology of lesions found in pocilloporids at four sites in the Mexican Pacific. Corals were identified and their lesions photographed and quantified in the field. Tissue samples were collected from healthy and affected colonies for histopathology. We recorded seven species of pocilloporids at the study sites with Isla Isabel being the location with the highest coral diversity (H′ = 1.27). Lesions were present in 42% of the colonies and included discoloration (32%), predation-induced tissue loss (30%), unexplained tissue loss (3%) and overgrowth by sponges or algae (35%). The most affected species, P. damicornis (50%), was also one of the most common in the region. No species was more prone to a particular lesion, but there was a significant association between location and the presence of lesions. Northern Islas Marietas (61%) and Isla Isabel (41%) had the highest prevalence of lesions, followed by Manzanillo (37%) and Bahías de Huatulco (23%). Histological changes included atrophy of the surface body wall with depletion of zooxanthellae (91%) in corals with discoloration (bleaching). Ablation of tissue from mesoglea (18%) was also observed. Colonies with unexplained tissue loss showed atrophy and thinning of the epidermis (89%), characterized by cuboidal instead of pseudocolumnar cells normally found in healthy pseudocolumnar ciliated epithelium. Bacterial aggregates between the mesoglea and gastrodermis (11%) were very conspicuous in healthy and diseased corals. Lesions produced by fish bites and gastropods were associated with tissue atrophy (40%) and, in some cases, algal overgrowth near the lesion (20%). No infectious agents associated with cell pathology were detected microscopically. Bleaching and overgrowth by algae and sponges, as well as unexplained tissue loss, are common in Pocillopora. These lesions and anatomical changes warrant further study since their incidence is potentially indicative of reef degradation.
An Investigation into the Use of Spatially-Filtered Fourier Transforms to Classify Mammary Lesions.
difference in Fourier space between lesioned breast tissue which would enable accurate computer classification of benign and malignant lesions. Low...separate benign and malignant breast tissue. However, no success was achieved when using two-dimensional Fourier transform and power spectrum analysis. (Author)
Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins.
Olabisi Arigbede, Abiodun; Folasade Adeyemi, Bukola; Femi-Akinlosotu, Omowumi
2017-01-01
Background. In vitro studies have revealed a direct association between resin content and cytotoxicity of composite resins; however, implantation studies in this regard are sparse. This study investigates the relationship between filler content of composite resins and biocompatibility. Methods. This research employed twelve 180‒200-gr male Wistar rats, 1 nano-hybrid (Prime-Dent Inc.) and 1 micro-hybrid (Medental Inc.) composite resins containing 74% and 80‒90% filler content, respectively. The samples were assessed on the 2nd, 14th and 90th day of implantation. Four rats were allocated to each day in this experimental study. A section of 1.5mm long cured nano-hybrid and micro-hybrid materials were implanted into the right and left upper and lower limbs of the rats, respectively. Eight samples were generated on each day of observation. Inflammation was graded according to the criteria suggested by Orstavik and Major. Pearson's chi-squared test was employed to determine the relationship between the tissue responses of the two materials. Statistical significance was set at P < 0.05. Results . The average grade of inflammation for the nano-hybrid on the 2nd day of implantation was 3.3. The micro-hybrid resin had a score of 3.0 for cellular inflammation. On the 14th day, the micro-hybrid resin also exhibited a lower average grade for cellular inflammation. On the 90th day, the micro-hybrid resin had a higher grade of inflammation (0.9) compared to 0.3 recorded for nano-hybrid. The composite resins with higher filler content elicited a significantly lower grade of inflammation irrespective of the duration (χ=20.000, df=8, P=0.010) while the composite resins with lower filler content elicited a significantly lower inflammatory response on the 90th day (χ=4.000, df=1, P=0.046). Conclusion. The composite resins with higher filler content generally elicited significantly lower grades of inflammation, and the composite resins with lower filler content exhibited significantly lower inflammatory response on the 90th day of implantation.
Relative biocompatibility of micro-hybrid and nano-hybrid light-activated composite resins
Olabisi Arigbede, Abiodun; Folasade Adeyemi, Bukola; Femi-Akinlosotu, Omowumi
2017-01-01
Background. In vitro studies have revealed a direct association between resin content and cytotoxicity of composite resins; however, implantation studies in this regard are sparse. This study investigates the relationship between filler content of composite resins and biocompatibility. Methods. This research employed twelve 180‒200-gr male Wistar rats, 1 nano-hybrid (Prime-Dent Inc.) and 1 micro-hybrid (Medental Inc.) composite resins containing 74% and 80‒90% filler content, respectively. The samples were assessed on the 2nd, 14th and 90th day of implantation. Four rats were allocated to each day in this experimental study. A section of 1.5mm long cured nano-hybrid and micro-hybrid materials were implanted into the right and left upper and lower limbs of the rats, respectively. Eight samples were generated on each day of observation. Inflammation was graded according to the criteria suggested by Orstavik and Major. Pearson’s chi-squared test was employed to determine the relationship between the tissue responses of the two materials. Statistical significance was set at P < 0.05. Results. The average grade of inflammation for the nano-hybrid on the 2nd day of implantation was 3.3. The micro-hybrid resin had a score of 3.0 for cellular inflammation. On the 14th day, the micro-hybrid resin also exhibited a lower average grade for cellular inflammation. On the 90th day, the micro-hybrid resin had a higher grade of inflammation (0.9) compared to 0.3 recorded for nano-hybrid. The composite resins with higher filler content elicited a significantly lower grade of inflammation irrespective of the duration (χ=20.000, df=8, P=0.010) while the composite resins with lower filler content elicited a significantly lower inflammatory response on the 90th day (χ=4.000, df=1, P=0.046). Conclusion. The composite resins with higher filler content generally elicited significantly lower grades of inflammation, and the composite resins with lower filler content exhibited significantly lower inflammatory response on the 90th day of implantation. PMID:28413588
NASA Astrophysics Data System (ADS)
Leproux, Anaïs; Kim, You Me; Min, Jun Won; McLaren, Christine E.; Chen, Wen-Pin; O'Sullivan, Thomas D.; Lee, Seung-ha; Chung, Phil-Sang; Tromberg, Bruce J.
2016-07-01
Young patients with dense breasts have a relatively low-positive biopsy rate for breast cancer (˜1 in 7). South Korean women have higher breast density than Westerners. We investigated the benefit of using a functional and metabolic imaging technique, diffuse optical spectroscopic imaging (DOSI), to help the standard of care imaging tools to distinguish benign from malignant lesions in premenopausal Korean women. DOSI uses near-infrared light to measure breast tissue composition by quantifying tissue concentrations of water (ctH2O), bulk lipid (ctLipid), deoxygenated (ctHHb), and oxygenated (ctHbO2) hemoglobin. DOSI spectral signatures specific to abnormal tissue and absent in healthy tissue were also used to form a malignancy index. This study included 19 premenopausal subjects (average age 41±9), corresponding to 11 benign and 10 malignant lesions. Elevated lesion to normal ratio of ctH2O, ctHHb, ctHbO2, total hemoglobin (THb=ctHHb+ctHbO2), and tissue optical index (ctHHb×ctH2O/ctLipid) were observed in the malignant lesions compared to the benign lesions (p<0.02). THb and malignancy index were the two best single predictors of malignancy, with >90% sensitivity and specificity. Malignant lesions showed significantly higher metabolism and perfusion than benign lesions. DOSI spectral features showed high discriminatory power for distinguishing malignant and benign lesions in dense breasts of the Korean population.
Enhanced Radiofrequency Ablation With Magnetically Directed Metallic Nanoparticles.
Nguyen, Duy T; Tzou, Wendy S; Zheng, Lijun; Barham, Waseem; Schuller, Joseph L; Shillinglaw, Benjamin; Quaife, Robert A; Sauer, William H
2016-05-01
Remote heating of metal located near a radiofrequency ablation source has been previously demonstrated. Therefore, ablation of cardiac tissue treated with metallic nanoparticles may improve local radiofrequency heating and lead to larger ablation lesions. We sought to evaluate the effect of magnetic nanoparticles on tissue sensitivity to radiofrequency energy. Ablation was performed using an ablation catheter positioned with 10 g of force over prepared ex vivo specimens. Tissue temperatures were measured and lesion volumes were acquired. An in vivo porcine thigh model was used to study systemically delivered magnetically guided iron oxide (FeO) nanoparticles during radiofrequency application. Magnetic resonance imaging and histological staining of ablated tissue were subsequently performed as a part of ablation lesion analysis. Ablation of ex vivo myocardial tissue treated with metallic nanoparticles resulted in significantly larger lesions with greater impedance changes and evidence of increased thermal conductivity within the tissue. Magnet-guided localization of FeO nanoparticles within porcine thigh preps was demonstrated by magnetic resonance imaging and iron staining. Irrigated ablation in the regions with greater FeO, after FeO infusion and magnetic guidance, created larger lesions without a greater incidence of steam pops. Metal nanoparticle infiltration resulted in significantly larger ablation lesions with altered electric and thermal conductivity. In vivo magnetic guidance of FeO nanoparticles allowed for facilitated radiofrequency ablation without direct infiltration into the targeted tissue. Further research is needed to assess the clinical applicability of this ablation strategy using metallic nanoparticles for the treatment of cardiac arrhythmias. © 2016 American Heart Association, Inc.
TSENG, HOW; LIN, SEY-EN; CHANG, YEN-LIANG; CHEN, MING-HSU; HUNG, SHIH-HAN
2016-01-01
The radiofrequency ablation (RFA) lesion size is posited to be disproportionate to the total delivered energy, and temperature-time integration (TTI) may have a more critical effect on lesion size. The present study aimed to evaluate this hypothesis by determining the temperature threshold and temperature distribution over tissues during the RFA lesioning process. Using an ex vivo chicken tissue model and an in vivo rabbit model with RFA applied for 2 min under various target temperature settings, the resultant lesions were evaluated histologically using Masson's trichrome stain. The temperature distribution over the tissue during the RFA lesioning process was also determined using a VT02 Visual IR Thermometer. It was revealed that the thermal injury threshold for RFA in the chicken tissues was ~65°C, but that it ranged from 55–65°C in mammals. Using infra-red thermal imaging, the temperature gradient (from the center to the periphery) during the RFA lesioning process demonstrated a uniform heat diffusion pattern. This data supports the proposed hypothesis that TTI is a critical parameter in determining RFA lesion size and can be applied clinically using the following equation: [Target temperature − 55 (°C)] × time (sec) is proportional to RFA lesion size. PMID:26997990
Bhowmik, Abhijit; Mallick Sinha, Mamata Guha; Barman, Dilip Chandra
2015-01-01
Diseases of the skin and superficial subcutaneous soft tissues present with a wide array of lesions ranging from nonspecific dermatoses and inflammatory lesions to frank neoplasms. Though cytopathology is an excellent diagnostic tool in routine dermatologic practice, studies relating to histopathological and cytological correlation are sparse. The aim of this study was to analyze the concordance rate between cytological and histopathological diagnosis of skin and superficial soft tissue lesions. We retrospectively studied 510 consecutive fine needle aspiration cytology findings of cases from North Bengal Medical College and Hospital and correlated their diagnoses based upon cytological and histopathological grounds. Out of the 510 cases studied, 253 were non neoplastic lesions and 257 were neoplastic. A high degree of concordance was observed (100% for malignant and 96.15% for benign lesions) when these two diagnostic modalities were compared. Histopathological correlation was possible in all malignant, 52/189 (27.51%) of benign and 27/253 (10.67%) of non-neoplastic lesions. Sensitivity and specificity of diagnoses were 95.31% and 97.6%, respectively. It can be safely concluded that fine needle aspiration cytology is a rapid, reliable and fairly accurate tool for initial triage and treatment of skin and superficial soft tissue lesions.
The effect of filler loading and morphology on the mechanical properties of contemporary composites.
Kim, Kyo-Han; Ong, Joo L; Okuno, Osamu
2002-06-01
Little information exists regarding the filler morphology and loading of composites with respect to their effects on selected mechanical properties and fracture toughness. The objectives of this study were to: (1) classify commercial composites according to filler morphology, (2) evaluate the influence of filler morphology on filler loading, and (3) evaluate the effect of filler morphology and loading on the hardness, flexural strength, flexural modulus, and fracture toughness of contemporary composites. Field emission scanning electron microscopy/energy dispersive spectroscopy was used to classify 3 specimens from each of 14 commercial composites into 4 groups according to filler morphology. The specimens (each 5 x 2.5 x 15 mm) were derived from the fractured remnants after the fracture toughness test. Filler weight content was determined by the standard ash method, and the volume content was calculated using the weight percentage and density of the filler and matrix components. Microhardness was measured with a Vickers hardness tester, and flexural strength and modulus were measured with a universal testing machine. A 3-point bending test (ASTM E-399) was used to determine the fracture toughness of each composite. Data were compared with analysis of variance followed by Duncan's multiple range test, both at the P<.05 level of significance. The composites were classified into 4 categories according to filler morphology: prepolymerized, irregular-shaped, both prepolymerized and irregular-shaped, and round particles. Filler loading was influenced by filler morphology. Composites containing prepolymerized filler particles had the lowest filler content (25% to 51% of filler volume), whereas composites containing round particles had the highest filler content (59% to 60% of filler volume). The mechanical properties of the composites were related to their filler content. Composites with the highest filler by volume exhibited the highest flexural strength (120 to 129 MPa), flexural modulus (12 to 15 GPa), and hardness (101 to 117 VHN). Fracture toughness was also affected by filler volume, but maximum toughness was found at a threshold level of approximately 55% filler volume. Within the limitations of this study, the commercial composites tested could be classified by their filler morphology. This property influenced filler loading. Both filler morphology and filler loading influenced flexural strength, flexural modulus, hardness, and fracture toughness.
Bai, Jing; Yang, Wei; Wang, Song; Guan, Rui-Hong; Zhang, Hui; Fu, Jing-Jing; Wu, Wei; Yan, Kun
2016-07-01
The purpose of this study was to explore the diagnostic value of the arrival time difference between lesions and surrounding lung tissue on contrast-enhanced sonography of subpleural pulmonary lesions. A total of 110 patients with subpleural pulmonary lesions who underwent both conventional and contrast-enhanced sonography and had a definite diagnosis were enrolled. After contrast agent injection, the arrival times in the lesion, lung, and chest wall were recorded. The arrival time differences between various tissues were also calculated. Statistical analysis showed a significant difference in the lesion arrival time, the arrival time difference between the lesion and lung, and the arrival time difference between the chest wall and lesion (all P < .001) for benign and malignant lesions. Receiver operating characteristic curve analysis revealed that the optimal diagnostic criterion was the arrival time difference between the lesion and lung, and that the best cutoff point was 2.5 seconds (later arrival signified malignancy). This new diagnostic criterion showed superior diagnostic accuracy (97.1%) compared to conventional diagnostic criteria. The individualized diagnostic method based on an arrival time comparison using contrast-enhanced sonography had high diagnostic accuracy (97.1%) with good feasibility and could provide useful diagnostic information for subpleural pulmonary lesions.
Evaluation of mast cell counts and microvessel density in reactive lesions of the oral cavity.
Kouhsoltani, Maryam; Moradzadeh Khiavi, Monir; Tahamtan, Shabnam
2016-01-01
Background. Reliable immunohistochemical assays to assess the definitive role of mast cells (MCs) and angiogenesis in the pathogenesis of oral reactive lesions are generally not available. The aim of the present study was to evaluate mast cell counts (MCC) and microvessel density (MVD) in oral reactive lesions and determine the correlation between MCC and MVD. Methods. Seventy-five cases of reactive lesions of the oral cavity, including pyogenic granuloma, fibroma, peripheral giant cell granuloma, inflammatory fibrous hyperplasia, peripheral ossifying fibroma (15 for each category) were immunohisto-chemically stained with MC tryptase and CD31. Fifteen cases of normal gingival tissue were considered as the control group. The mean MCC and MVD in superficial and deep connective tissues were assessed and total MCC and MVD was computed for each lesion. Results . Statistically significant differences were observed in MCC and MVD between the study groups (P < 0.001). MC tryptase and CD31 expression increased in the superficial connective tissue of each lesion in comparison to the deep con-nective tissue. A significant negative correlation was not found between MCC and MVD in oral reactive lesions (P < 0.001, r = -0.458). Conclusion. Although MCs were present in the reactive lesions of the oral cavity, a direct correlation between MCC and MVD was not found in these lesions. Therefore, a significant interaction between MCs and endothelial cells and an active role for MCs in the growth of oral reactive lesions was not found in this study.
di Lauro, A E; Abbate, D; Dell'Angelo, B; Iannaccone, G A; Scotto, F; Sammartino, G
2015-11-02
Leukocyte-platelet rich fibrin belongs to a second generation of platelet concentrates that does not need biochemical blood manipulation. It is used for tissue healing and regeneration in periodontal and oral-maxillofacial surgery. We report two cases of hyperplastic gingival lesions treated by exeresis and application of leukocyte-platelet rich fibrin membranes in order to improve and accelerate tissue healing. Two patients (a 78-year-old Caucasian woman and a 30-year-old Caucasian man) were treated for hyperplastic gingival lesions. They underwent to exeresis of lesions and application of leukocyte-platelet rich fibrin membranes. Tissue healing was clinically evaluated after 1, 3, 7, 14 and 30 postoperative days. No recurrences were observed after 2 years of semi-annual follow up. We obtained rapid and good healing of soft tissues probably due to the elevated content of leukocytes, platelets and growth factors in the leukocyte-platelet rich fibrin. Based on our results we suggest the use of leukocyte-platelet rich fibrin to cover wounds after exeresis of oral neoformations such as hyperplastic gingival lesions.
Explained and unexplained tissue loss in corals from the Tropical Eastern Pacific
Rodriguez-Villalobos, Jenny Carolina; Work, Thierry M.; Calderon-Aguilera, Luis Eduardo; Reyes-Bonilla, Hector; Hernández, Luis
2015-01-01
Coral reefs rival rainforest in biodiversity, but are declining in part because of disease. Tissue loss lesions, a manifestation of disease, are present in dominant Pocillopora along the Pacific coast of Mexico. We characterized tissue loss in 7 species of Pocillopora from 9 locations (44 sites) spanning southern to northern Mexico. Corals were identified to species, and tissue loss lesions were photographed and classified as those explainable by predation and those that were unexplained. A focal predation study was done concurrently at 3 locations to confirm origin of explained lesions. Of 1054 cases of tissue loss in 7 species of corals, 84% were associated with predation (fish, snails, or seastar) and the remainder were unexplained. Types of tissue loss were not related to coral density; however there was significant geographic heterogeneity in type of lesion; one site in particular (Cabo Pulmo) had the highest prevalence of predator-induced tissue loss (mainly pufferfish predation). Crown-of-thorns starfish, pufferfish, and snails were the most common predators and preferred P. verrucosa, P. meandrina, and P. capitata, respectively. Of the 9 locations, 4 had unexplained tissue loss with prevalence ranging from 1 to 3% with no species predilection. Unexplained tissue loss was similar to white syndrome (WS) in morphology, indicating additional study is necessary to clarify the cause(s) of the lesions and the potential impacts to dominant corals along the Pacific coast of Mexico.
Biocompatibility and tissue interactions of a new filler material for medical use.
Zarini, Elena; Supino, Rosanna; Pratesi, Graziella; Laccabue, Diletta; Tortoreto, Monica; Scanziani, Eugenio; Ghisleni, Gabriele; Paltrinieri, Saverio; Tunesi, Gianfranco; Nava, Maurizio
2004-09-15
Filler materials for medical use present limits, such as the induction of chronic inflammation and fibrosis. In the search for synthetic materials with improved biocompatible properties, a new polyacrylamide hydrogel, Aquamid (Contura SA, Montreux, Switzerland), has been investigated in preclinical systems. In cell cultures (endothelial cells and fibroblast), no or only transient biological effects were associated with 10% Aquamid exposure. The Aquamid-host interactions were examined in mice (10 mice per group) implanted subcutaneously or in the mammary fat pad with a very large volume (1.5 ml) of the material. Blood analysis, performed after 15 and 94 days (five mice per time for each group) to detect acute or late manifestations of toxicity, did not reveal relevant abnormalities in either group of Aquamid-bearing mice compared with control mice, except for a transient thrombocytopenia and a mild leukocytosis. Histological analysis of the pellet showed the presence of a thin, poorly vascularized cyst wall in implants. Only mild mesenchymal reparative and inflammatory processes were observed, even at longer observation times (more than 400 days). No alterations in any organ were detected. Despite the large volume implanted (approximately 5 percent of mouse body weight), the Aquamid pellet maintained its original size and shape without spreading or sticking to surrounding tissues. In conclusion, the study indicated a good tolerability of the new biopolymer in preclinical systems. The clinical utility of this new compound, if confirmed by clinical randomized trials showing its atoxic properties, could be in the field of aesthetic plastic surgery as a filler material for body contouring and in reconstructive surgery and above all in cancer patients to restore surgical defects.
Raj, Indu; Mozetic, Miran; Jayachandran, V P; Jose, Jiya; Thomas, Sabu; Kalarikkal, Nandakumar
2018-07-27
Antimicrobial, antibiofilm adherent, fracture resistant nano zinc oxide (ZnO NP) formulations based on poly methyl methacrylate (PMMA) matrix were developed using a facile ex situ compression moulding technique. These formulations demonstrated potent, long-term biofilm-resisting effects against Candida albicans (9000 CFU to 1000 CFU) and Streptococcus mutans. Proposed mechanism of biofilm resistance was the release of metallic ions/metal oxide by 'particle-corrosion'. MTT and cellular proliferation assays confirmed both qualitatively and quantitatively equal human skin fibroblast cell line proliferations (approximately 75%) on both PMMA/ZnO formulation and neat PMMA. Mechanical performance was evaluated over a range of filler loading, and theoretical models derived from Einstein, Guth, Thomas and Quemade were chosen to predict the modulus of the nanoformulations. All the models gave better fitting at lower filler content, which could be due to restricted mobility of the polymer chains by the constrained zone/interfacial rigid amorphous zone and also due to stress absorption by the highly energized NPs. Fracture mechanics were clearly described based on substantial experimental evidence surrounding crack prevention in the initial zones of fracture. Filler-polymer interactions at the morphological and structural levels were elucidated through FTIR, XRD, SEM, TEM and AFM analyses. Major clinical challenges in cancer patient rehabilitation and routine denture therapy are frequent breakage of the prostheses and microbial colonization on the prostheses/tissues. In the present study, we succeeded in developing an antimicrobial, mechanically improved fracture resistant, biocompatible nanoformulation in a facile manner without the bio-toxic effects of surface modifiers/functionalization. This PMMA/ZnO nanoformulation could serve as a cost effective breakthrough biomaterial in the field of prosthetic rehabilitation and local drug delivery scaffolds for abused tissues.
Melorheostosis of the axial skeleton with associated fibrolipomatous lesions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garver, P.; Resnick, D.; Haghighi, P.
1982-11-01
Two patients with melorheostotic-like lesions of the axial skeleton are described. In each case adjacent soft tissue masses containing both fatty and fibrous tissues were evident. The presence of such soft tissue tumors as well as other soft tissue abnormalities in melorheostosis emphasizes that the diesease should not be regarded as one confined to bone. The precise pathogenesis of the osseous and soft tissue abnormalities in melorheostosis remains obscure.
Alopecia with foreign body granulomas induced by Radiesse injection: A case report.
Liu, Ren-Feng; Kuo, Tseng-Tong; Chao, Yen-Yu; Huang, Yu-Huei
2018-02-26
Radiesse is a soft tissue filler which has been widely used for cosmetic enhancement. The safety of Radiesse has been thoroughly investigated via numerous studies. A late-onset complication of Radiesse injection consists of foreign body granulomas, with only three case reports in over 10 years of clinical use. Herein, we describe the case of a patient who experienced alopecia with foreign body granulomas at the injection region one month after receiving a Radiesse injection. To our knowledge, this is the first report in the English literature of alopecia as an adverse event associated with Radiesse injection. The present case reminded physicians to evaluate more cautiously the necessity of injecting filler into hair-bearing area for lifting purpose. This procedure may cause foreign body granulomatous reaction, which may result in hair loss at the injection region.
Nguyen, Huy Bang; Thai, Truc Quynh; Saitoh, Sei; Wu, Bao; Saitoh, Yurika; Shimo, Satoshi; Fujitani, Hiroshi; Otobe, Hirohide; Ohno, Nobuhiko
2016-01-01
Recent advances in serial block-face imaging using scanning electron microscopy (SEM) have enabled the rapid and efficient acquisition of 3-dimensional (3D) ultrastructural information from a large volume of biological specimens including brain tissues. However, volume imaging under SEM is often hampered by sample charging, and typically requires specific sample preparation to reduce charging and increase image contrast. In the present study, we introduced carbon-based conductive resins for 3D analyses of subcellular ultrastructures, using serial block-face SEM (SBF-SEM) to image samples. Conductive resins were produced by adding the carbon black filler, Ketjen black, to resins commonly used for electron microscopic observations of biological specimens. Carbon black mostly localized around tissues and did not penetrate cells, whereas the conductive resins significantly reduced the charging of samples during SBF-SEM imaging. When serial images were acquired, embedding into the conductive resins improved the resolution of images by facilitating the successful cutting of samples in SBF-SEM. These results suggest that improving the conductivities of resins with a carbon black filler is a simple and useful option for reducing charging and enhancing the resolution of images obtained for volume imaging with SEM. PMID:27020327
Endoscopic treatment of Morel-Lavallee lesion.
Kim, Sunghoon
2016-05-01
Morel-Lavallee lesion is a closed degloving soft tissue injury in which subcutaneous tissue is torn from the underlying muscular fascia. The tear leads to venolymphatic leak, and concomitant adipose tissue necrosis from the force of the trauma causes swelling and possible infection at the site of injury. The traditional treatment for the lesion is surgical drainage and debridement. In this report, an endoscopic method is described, which achieves the goal of an open surgical debridement but minimizes surgical morbidity. Copyright © 2016 Elsevier Ltd. All rights reserved.
Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods
Tadic, Mario; Stoos-Veic, Tajana; Kusec, Rajko
2014-01-01
The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy. PMID:25339816
Detecting skin malignancy using elastic light scattering spectroscopy
NASA Astrophysics Data System (ADS)
Canpolat, Murat; Akman, Ayşe; Çiftçioğlu, M. Akif; Alpsoy, Erkan
2007-07-01
We have used elastic light scattering spectroscopy to differentiate between malign and benign skin lesions. The system consists of a UV spectrometer, a single optical fiber probe and a laptop. The single optical fiber probe was used for both delivery and detection of white light to tissue and from the tissue. The single optical fiber probe received singly scattered photons rather than diffused photons in tissue. Therefore, the spectra are correlated with morphological differences of the cells. It has been shown that spectra of malign skin lesions are different than spectra of benign skin lesions. While slopes of the spectra taken on benign lesions or normal skin tissues were positive, slopes of the spectra taken on malign skin lesions tissues were negative. In vivo experiments were conducted on 20 lesions from 18 patients (11 men with mean age of 68 +/- 9 years and 7 women with mean age of 52 +/- 20 years) applied to the Department of Dermatology and Venerology. Before the biopsy, spectra were taken on the lesion and adjacent (approximately 1 cm distant) normal-appearing skin. Spectra of the normal skin were used as a control group. The spectra were correlated to the pathology results with sensitivity and specificity of 82% and 89%, respectively. Due to small diameter of fiber probe and limited number of sampling (15), some positive cases are missed, which is lowered the sensitivity of the system. The results are promising and could suggest that the system may be able to detect malignant skin lesion non-invasively and in real time.
Adaptive lesion formation using dual mode ultrasound array system
NASA Astrophysics Data System (ADS)
Liu, Dalong; Casper, Andrew; Haritonova, Alyona; Ebbini, Emad S.
2017-03-01
We present the results from an ultrasound-guided focused ultrasound platform designed to perform real-time monitoring and control of lesion formation. Real-time signal processing of echogenicity changes during lesion formation allows for identification of signature events indicative of tissue damage. The detection of these events triggers the cessation or the reduction of the exposure (intensity and/or time) to prevent overexposure. A dual mode ultrasound array (DMUA) is used for forming single- and multiple-focus patterns in a variety of tissues. The DMUA approach allows for inherent registration between the therapeutic and imaging coordinate systems providing instantaneous, spatially-accurate feedback on lesion formation dynamics. The beamformed RF data has been shown to have high sensitivity and specificity to tissue changes during lesion formation, including in vivo. In particular, the beamformed echo data from the DMUA is very sensitive to cavitation activity in response to HIFU in a variety of modes, e.g. boiling cavitation. This form of feedback is characterized by sudden increase in echogenicity that could occur within milliseconds of the application of HIFU (see http://youtu.be/No2wh-ceTLs for an example). The real-time beamforming and signal processing allowing the adaptive control of lesion formation is enabled by a high performance GPU platform (response time within 10 msec). We present results from a series of experiments in bovine cardiac tissue demonstrating the robustness and increased speed of volumetric lesion formation for a range of clinically-relevant exposures. Gross histology demonstrate clearly that adaptive lesion formation results in tissue damage consistent with the size of the focal spot and the raster scan in 3 dimensions. In contrast, uncontrolled volumetric lesions exhibit significant pre-focal buildup due to excessive exposure from multiple full-exposure HIFU shots. Stopping or reducing the HIFU exposure upon the detection of such an events has been shown to produce precisely controlled lesions with no evidence of overexposure even when fast raster scan of volumetric HIFU lesion is attempted. We also show that the DMUA beamformed echo data is capable of detecting underexposure condition at the target location, e.g. due to the obstruction of the HIFU beam resulting from cavitation activity in the path of the beam. The results clearly demonstrate the advantage of adaptive lesion formation in reducing the treatment time while confining the tissue damage to the target volume.
NASA Astrophysics Data System (ADS)
Iskander-Rizk, Sophinese; Kruizinga, Pieter; van der Steen, Antonius F. W.; van Soest, Gijs
2017-03-01
Radio-frequency ablation (RFA) creates a thermal lesion in the atrial wall, with clearly recognizable optical and structural changes to the tissue. This can be detected by photoacoustic (PA) imaging, and used for monitoring of lesion depth, lesion functionality, and limiting excessive ablation. Porcine left atrium tissue can be split into three visually distinguishable regions, a thick white endocardium, pinkish myocardium and a thin gelatinous epicardium. In this study, we characterize the layered left atrium tissue in terms of the relevant photoacoustic parameters (wavelength, frequency content, imaging depth, lesion contrast). Previous studies in the literature targeted the photoacoustic characterization of fresh and ablated ventricular myocardium in the range of 650nm to 900nm. In this study we target the characterization of fresh and ablated left atrial tissue from 410nm to 1000nm, including the endocardium and epicardium. We generate the photoacoustic signals using a tunable pulsed laser source, and record those signals using either a broadband 1 mm hydrophone or a L12-3v transducer connected to the Verasonics machine for more realistic conditions. Initial experiments on fresh porcine tissue show that the presence of the endocardium and epicardium layers do affect the photoacoustic signal received. The signal recorded is representative of the difference in optical and mechanical properties between the layers. Ablated and non-ablated tissue also present differences in spectra. The determined optical contrast could be used in the PA monitoring of RFA lesion to monitor the extension of the lesion to the edge of the myocardium-epicardium border avoiding complications related to over ablation.
Characteristic Asphalt Concrete Wearing Course (ACWC) Using Variation Lime Filler
NASA Astrophysics Data System (ADS)
Permana, R. A.; Pramesti, F. P.; Setyawan, A.
2018-03-01
This research use of lime filler Sukaraja expected add durability layers of concrete pavement is asphalt damage caused by the weather and load traffic. This study attempts to know how much value characteristic Marshall on a mixture of concrete asphalt using lime filler. This research uses experimental methods that is with a pilot to get results, thus will look filler utilization lime on construction concrete asphalt variation in filler levels 2 %, 3 %, 4 %.The results showed that the use of lime filler will affect characteristic a mixture of concrete asphalt. The more filler chalk used to increase the value of stability. On the cretaceous filler 2 % value of stability is 1067,04 kg. When lime filler levels added to the levels of filler 4 %, the value of stability increased to 1213,92 kg. The flexibility increased the number of filler as levels lime 2 % to 4 % suggests that are conducted more stiff mix.
Nemoto, Akira; Chosa, Naoyuki; Kyakumoto, Seiko; Yokota, Seiji; Kamo, Masaharu; Noda, Mamoru; Ishisaki, Akira
2018-01-01
Surface pre-reacted glass-ionomer (S-PRG)-containing dental materials, including composite and coating resins have been used for the restoration and/or prevention of dental cavities. S-PRG is known to have the ability to release aluminum, boron, fluorine, silicon, and strontium ions. Aluminum ions are known to be inhibitors whereas boron, fluorine, silicon, and strontium ions are known to be promoters of mineralization, via osteoblasts. However, it remains to be clarified how an aqueous eluate obtained from S-PRG containing these ions affects the ability of mesenchymal stem cells (MSCs), which are known to be present in dental pulp and bone marrow, to differentiate into osteogenic cell types. The present study demonstrated that 200- to 1,000-fold-diluted aqueous eluates obtained from S-PRG significantly upregulated the mRNA expression level of the osteogenic differentiation marker alkaline phosphatase in human MSCs (hMSCs) without exhibiting the cytotoxic effect. In addition, the 500- to 1,000-fold-diluted aqueous eluates obtained from S-PRG significantly and clearly promoted mineralization of the extracellular matrix of hMSCs. It was additionally demonstrated that hMSCs cultured on the cured resin composites containing S-PRG fillers exhibited osteogenic differentiation in direct correlation with the weight percent of S-PRG fillers. These results strongly suggested that aqueous eluates of S-PRG fillers promoted hard tissue formation by hMSCs, implicating that resins containing S-PRG may act as a useful biomaterial to cover accidental exposure of dental pulp. PMID:29257332
Oppelt, Peter; Renner, Stefan P; Strick, Reiner; Valletta, Daniela; Mehlhorn, Grit; Fasching, Peter A; Beckmann, Matthias W; Strissel, Pamela L
2010-04-01
To investigate whether sexually transmitted viruses or prokaryotes, like human papilloma viruses (HPV), herpes viruses, and Chlamydia trachomatis, are associated with endometriosis lesions. Sixty-six endometriosis lesions from 56 patients, including 49 peritoneum, 16 ovarian, and one endometrium, were analyzed using polymerase chain reaction-based ELISA and Invader technology. Thirty control tissues including endometrium and peritoneum from patient-matched (n = 13) and patients without endometriosis (n = 13) and one cervical carcinoma were tested for HPV DNA. University hospital. Seventy individual patients with and without endometriosis. Laparoscopy or laparotomy was performed, and endometriotic lesions were isolated. Herpes viruses and Chlamydia trachomatis were not detected in endometriosis lesions. High-risk and medium-risk HPV were detected in 11.3% of lesions, corresponding to 13.2% of patients. In addition, 27.5% of control tissues were positive for HPV high and medium risk. One HPV18-positive ovarian endometriosis also associated with an ovarian carcinoma. Associating clinical history with HPV-positive endometriosis and control tissues, all patients had a prior HPV cervical infection. HPV infection in endometriosis lesions including control tissues supports spreading of the virus or HPV-infected endometrial cells via retrograde menstruation. Owing to an association of HPV in carcinomas, we propose that persistent HPV infection of endometriosis lesions could contribute to malignant progression. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Okuni, Julius Boniface; Reinacher, Manfred; Loukopoulos, Panayiotis; Ojok, Lonzy
2013-06-01
This study was conducted to determine the prevalence and characteristics of Johne's disease (JD) lesions in Ugandan cattle slaughtered at two of the main abattoirs in Kampala. Ileocaecal junction and the associated lymph nodes of 1,022 cattle were examined for gross and microscopic lesions, followed by Ziehl Neelsen staining of the tissues bearing lesions. Confirmation of Mycobacterium avium subsp. paratuberculosis infection was done in some of the tissues using culture and IS900 PCR. The lesions were then described, characterised and tabulated. Characteristic Johne's disease granulomas were found in 4.7% of the samples examined, derived from Zebu, Ankole longhorn, Friesian breeds of cattle and their crosses. Lesions were found both in the lymph nodes and ileocaecal junction mucosa. The lesions tended to be more severe in the lymph node than in the mucosa. There were also some unique and atypical lesions found in association with Johne's disease granulomas. The diagnostic values of various gross lesions and criteria of lesion classifications and diagnosis are revisited and discussed based on the findings of this study. The prevalence of Johne's disease lesions among slaughtered cattle in Kampala's two abattoirs indicates that the disease is well established in the cattle population in the country. The diverse manifestations in lesions of JD need to be considered when making histological diagnosis in tissues where the disease is suspected.
Ding, Huanjun; Sennung, David; Cho, Hyo-Min; Molloi, Sabee
2016-01-01
Purpose: The positive predictive power for malignancy can potentially be improved, if the chemical compositions of suspicious breast lesions can be reliably measured in screening mammography. The purpose of this study is to investigate the feasibility of quantifying breast lesion composition, in terms of water and lipid contents, with spectral mammography. Methods: Phantom and tissue samples were imaged with a spectral mammography system based on silicon-strip photon-counting detectors. Dual-energy calibration was performed for material decomposition, using plastic water and adipose-equivalent phantoms as the basis materials. The step wedge calibration phantom consisted of 20 calibration configurations, which ranged from 2 to 8 cm in thickness and from 0% to 100% in plastic water density. A nonlinear rational fitting function was used in dual-energy calibration of the imaging system. Breast lesion phantoms, made from various combinations of plastic water and adipose-equivalent disks, were embedded in a breast mammography phantom with a heterogeneous background pattern. Lesion phantoms with water densities ranging from 0% to 100% were placed at different locations of the heterogeneous background phantom. The water density in the lesion phantoms was measured using dual-energy material decomposition. The thickness and density of the background phantom were varied to test the accuracy of the decomposition technique in different configurations. In addition, an in vitro study was also performed using mixtures of lean and fat bovine tissue of 25%, 50%, and 80% lean weight percentages as the background. Lesions were simulated by using breast lesion phantoms, as well as small bovine tissue samples, composed of carefully weighed lean and fat bovine tissues. The water densities in tissue samples were measured using spectral mammography and compared to measurement using chemical decomposition of the tissue. Results: The thickness of measured and known water contents was compared for various lesion configurations. There was a good linear correlation between the measured and the known values. The root-mean-square errors in water thickness measurements were 0.3 and 0.2 mm for the plastic phantom and bovine tissue backgrounds, respectively. Conclusions: The results indicate that spectral mammography can be used to accurately characterize breast lesion composition in terms of their equivalent water and lipid contents. PMID:27782705
Miyaki, Rie; Yoshida, Shigeto; Tanaka, Shinji; Kominami, Yoko; Sanomura, Yoji; Matsuo, Taiji; Oka, Shiro; Raytchev, Bisser; Tamaki, Toru; Koide, Tetsushi; Kaneda, Kazufumi; Yoshihara, Masaharu; Chayama, Kazuaki
2015-02-01
To evaluate the usefulness of a newly devised computer system for use with laser-based endoscopy in differentiating between early gastric cancer, reddened lesions, and surrounding tissue. Narrow-band imaging based on laser light illumination has come into recent use. We devised a support vector machine (SVM)-based analysis system to be used with the newly devised endoscopy system to quantitatively identify gastric cancer on images obtained by magnifying endoscopy with blue-laser imaging (BLI). We evaluated the usefulness of the computer system in combination with the new endoscopy system. We evaluated the system as applied to 100 consecutive early gastric cancers in 95 patients examined by BLI magnification at Hiroshima University Hospital. We produced a set of images from the 100 early gastric cancers; 40 flat or slightly depressed, small, reddened lesions; and surrounding tissues, and we attempted to identify gastric cancer, reddened lesions, and surrounding tissue quantitatively. The average SVM output value was 0.846 ± 0.220 for cancerous lesions, 0.381 ± 0.349 for reddened lesions, and 0.219 ± 0.277 for surrounding tissue, with the SVM output value for cancerous lesions being significantly greater than that for reddened lesions or surrounding tissue. The average SVM output value for differentiated-type cancer was 0.840 ± 0.207 and for undifferentiated-type cancer was 0.865 ± 0.259. Although further development is needed, we conclude that our computer-based analysis system used with BLI will identify gastric cancers quantitatively.
Fluorescence lifetime of normal, benign, and malignant thyroid tissues
NASA Astrophysics Data System (ADS)
Brandao, Mariana; Iwakura, Ricardo; Basilio, Fagne; Haleplian, Kaique; Ito, Amando; de Freitas, Luiz Carlos Conti; Bachmann, Luciano
2015-06-01
Fine-needle aspiration cytology is the standard technique to diagnose thyroid pathologies. However, this method results in a high percentage of inconclusive and false negatives. The use of time-resolved fluorescence techniques to detect biochemical composition and tissue structure alterations could help to develop a portable, minimally invasive, and nondestructive method to assist during surgical procedures. This study aimed to use fluorescence lifetimes to differentiate healthy and benign tissues from malignant thyroid tissue. The thyroid tissue was excited at 298-300 nm and the fluorescence decay registered at 340 and 450 nm. We observed fluorescence lifetimes at 340 nm emission of 0.80±0.26 and 3.94±0.47 ns for healthy tissue; 0.90±0.24 and 4.05±0.46 ns for benign lesions; and 1.21±0.14 and 4.63±0.25 ns for malignant lesions. For 450 nm emissions, we obtain lifetimes of 0.25±0.18 and 3.99±0.39 ns for healthy tissue, 0.24±0.17 and 4.20±0.48 ns for benign lesions, 0.33±0.32 and 4.55±0.55 ns for malignant lesions. Employing analysis of variance, we differentiate malignant lesions from benign and healthy tissues. In addition, we use quadratic discriminant analysis to distinguish malignant from benign and healthy tissues with an accuracy of 76.1%, sensitivity of 74.7%, and specificity of 83.3%. These results indicate that time-resolved fluorescence can assist medical evaluation of thyroid pathologies during surgeries.
Dubey, Jitender P; Ferreira, Leandra R; Alsaad, Mohammad; Verma, Shiv K; Alves, Derron A; Holland, Gary N; McConkey, Glenn A
2016-01-01
The protozoan parasite Toxoplasma gondii is one of the most widely distributed and successful parasites. Toxoplasma gondii alters rodent behavior such that infected rodents reverse their fear of cat odor, and indeed are attracted rather than repelled by feline urine. The location of the parasite encysted in the brain may influence this behavior. However, most studies are based on the highly susceptible rodent, the mouse. Latent toxoplasmosis was induced in rats (10 rats per T. gondii strains) of the same age, strain, and sex, after oral inoculation with oocysts (natural route and natural stage of infection) of 11 T. gondii strains of seven genotypes. Rats were euthanized at two months post inoculation (p.i.) to investigate whether the parasite genotype affects the distribution, location, tissue cyst size, or lesions. Tissue cysts were enumerated in different regions of the brains, both in histological sections as well in saline homogenates. Tissue cysts were found in all regions of the brain. The tissue cyst density in different brain regions varied extensively between rats with many regions highly infected in some animals. Overall, the colliculus was most highly infected although there was a large amount of variability. The cerebral cortex, thalamus, and cerebellum had higher tissue cyst densities and two strains exhibited tropism for the colliculus and olfactory bulb. Histologically, lesions were confined to the brain and eyes. Tissue cyst rupture was frequent with no clear evidence for reactivation of tachyzoites. Ocular lesions were found in 23 (25%) of 92 rat eyes at two months p.i. The predominant lesion was focal inflammation in the retina. Tissue cysts were seen in the sclera of one and in the optic nerve of two rats. The choroid was not affected. Only tissue cysts, not active tachyzoite infections, were detected. Tissue cysts were seen in histological sections of tongue of 20 rats but not in myocardium and leg muscle. This study reevaluated in depth the rat model of toxoplasmosis visualizing cyst rupture and clarified many aspects of the biology of the parasite useful for future investigations.
Location- and lesion-dependent estimation of mammographic background tissue complexity.
Avanaki, Ali; Espig, Kathryn; Kimpe, Tom
2017-01-01
We specify a notion of perceived background tissue complexity (BTC) that varies with lesion shape, lesion size, and lesion location in the image. We propose four unsupervised BTC estimators based on: perceived pre and postlesion similarity of images, lesion border analysis (LBA; conspicuous lesion should be brighter than its surround), tissue anomaly detection, and local energy. The latter two are existing methods adapted for location- and lesion-dependent BTC estimation. For evaluation, we ask human observers to measure BTC (threshold visibility amplitude of a given lesion inserted) at specified locations in a mammogram. As expected, both human measured and computationally estimated BTC vary with lesion shape, size, and location. BTCs measured by different human observers are correlated ([Formula: see text]). BTC estimators are correlated to each other ([Formula: see text]) and less so to human observers ([Formula: see text]). With change in lesion shape or size, LBA estimated BTC changes in the same direction as human measured BTC. Proposed estimators can be generalized to other modalities (e.g., breast tomosynthesis) and used as-is or customized to a specific human observer, to construct BTC-aware model observers with applications, such as optimization of contrast-enhanced medical imaging systems and creation of a diversified image dataset with characteristics of a desired population.
Location- and lesion-dependent estimation of mammographic background tissue complexity
Avanaki, Ali; Espig, Kathryn; Kimpe, Tom
2017-01-01
Abstract. We specify a notion of perceived background tissue complexity (BTC) that varies with lesion shape, lesion size, and lesion location in the image. We propose four unsupervised BTC estimators based on: perceived pre and postlesion similarity of images, lesion border analysis (LBA; conspicuous lesion should be brighter than its surround), tissue anomaly detection, and local energy. The latter two are existing methods adapted for location- and lesion-dependent BTC estimation. For evaluation, we ask human observers to measure BTC (threshold visibility amplitude of a given lesion inserted) at specified locations in a mammogram. As expected, both human measured and computationally estimated BTC vary with lesion shape, size, and location. BTCs measured by different human observers are correlated (ρ=0.67). BTC estimators are correlated to each other (0.84<ρ<0.95) and less so to human observers (ρ≤0.81). With change in lesion shape or size, LBA estimated BTC changes in the same direction as human measured BTC. Proposed estimators can be generalized to other modalities (e.g., breast tomosynthesis) and used as-is or customized to a specific human observer, to construct BTC-aware model observers with applications, such as optimization of contrast-enhanced medical imaging systems and creation of a diversified image dataset with characteristics of a desired population. PMID:28097214
Ertas, Gokhan; Onaygil, Can; Akin, Yasin; Kaya, Handan; Aribal, Erkin
2016-12-01
To investigate the accuracy of diffusion coefficients and diffusion coefficient ratios of breast lesions and of glandular breast tissue from mono- and stretched-exponential models for quantitative diagnosis in diffusion-weighted magnetic resonance imaging (MRI). We analyzed pathologically confirmed 170 lesions (85 benign and 85 malignant) imaged using a 3.0T MR scanner. Small regions of interest (ROIs) focusing on the highest signal intensity for lesions and also for glandular tissue of contralateral breast were obtained. Apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were estimated by performing nonlinear fittings using mono- and stretched-exponential models, respectively. Coefficient ratios were calculated by dividing the lesion coefficient by the glandular tissue coefficient. A stretched exponential model provides significantly better fits then the monoexponential model (P < 0.001): 65% of the better fits for glandular tissue and 71% of the better fits for lesion. High correlation was found in diffusion coefficients (0.99-0.81 and coefficient ratios (0.94) between the models. The highest diagnostic accuracy was found by the DDC ratio (area under the curve [AUC] = 0.93) when compared with lesion DDC, ADC ratio, and lesion ADC (AUC = 0.91, 0.90, 0.90) but with no statistically significant difference (P > 0.05). At optimal thresholds, the DDC ratio achieves 93% sensitivity, 80% specificity, and 87% overall diagnostic accuracy, while ADC ratio leads to 89% sensitivity, 78% specificity, and 83% overall diagnostic accuracy. The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641. © 2016 International Society for Magnetic Resonance in Medicine.
Gold nanoshell thermal confinement of conformal laser thermal therapy in liver metastasis
NASA Astrophysics Data System (ADS)
Elliott, Andrew M.; Wang, James; Shetty, Anil M.; Schwartz, Jon; Hazle, John D.; Stafford, R. Jason
2008-02-01
Cooled fiber tip technology has significantly improved the volume coverage of laser induced thermal therapy (LITT), making LITT an attractive technology for the minimally invasive treatment of cancer. Gold coated nanoshells can be tuned to experience a plasmon resonance at a desired laser frequency, there introduction into the treatment region can greatly amplify the effectiveness of the thermal treatment. The goal is to conformaly heat the target, while sparing surrounding healthy tissue. To this end a treatment option that is self-confining to the target lesion is highly desirable. This can be achieved in the liver by allowing nanoshells to be taken up by the healthy tissue of the liver as part of their natural removal from the blood stream. The lesion is then incased inside the nanoshell laden tissue of the surrounding healthy tissue. When an interstitial laser probe is introduced into the center of the lesion the thermal radiation scatters outward until it interacts with and is absorbed by the nanoshells located around the lesion periphery. As the periphery heats it acts as secondary source of thermal radiation, sending heat back into lesion and giving rise to ablative temperatures within the lesion while sparing the surrounding tissue. In order to better monitor therapy and know when the target volume has been ablated, or exceeded, accurate knowledge is needed of both the spatial distribution of heating and the maximum temperature achieved. Magnetic resonance temperature imaging (MRTI) is capable of monitoring the spatiotemporal distribution of temperature in vivo[1]. Experiments have been performed in vitro using a dog liver containing nanoshells (concentration 860ppm) and a tissue like lesion phantom designed to have the optical properties of liver metastasis [2].
Häcker, Axel; Köhrmann, Kai Uwe; Knoll, Thomas; Langbein, Sigrun; Steidler, Annette; Kraut, Oliver; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan
2004-11-01
The therapeutic application of noninvasive tissue ablation by high-intensity focused ultrasound (HIFU) requires precise physical definition of the focal size and determination of control parameters. The objective of this study was to measure the extent of ex-vivo porcine kidney tissue ablation at variable generator parameters and to identify parameters to control lesion size. The ultrasound waves generated by a cylindrical piezoceramic element (1.04 MHz) were focused at a depth of 100 mm using a parabolic reflector (diameter 100 mm). A needle hydrophone was used to measure the field distribution of the sound pressure. The morphology and extent of tissue necrosis were examined at generator powers of up to 400 W (P(el)) and single pulse durations of as long as 8 seconds. The two-dimensional field distribution resulted in an approximately ellipsoidal focus of 32 x 4 mm (-6 dB). A sharp demarcation between coagulation necrosis and intact tissue was observed. Lesion size was controlled by both the variation of generator power and the pulse duration. At a constant pulse duration of 2 seconds, a generator power of 100 W remained below the threshold doses for inducing a reproducible lesion. An increase in power to as high as 400 W induced lesions with average dimensions of as much as 11.2 x 3 mm. At constant total energy (generator power x pulse duration), lesion size increased at higher generator power. This ultrasound generator can induce defined and reproducible necrosis in ex-vivo kidney tissue. Lesion size can be controlled by adjusting the generator power and pulse duration. Generator power, in particular, turned out to be a suitable control parameter for obtaining a lesion of a defined size.
Connective Tissue Nevi: A Review of the Literature.
Arora, Harleen; Falto-Aizpurua, Leyre; Cortés-Fernandez, Andrea; Choudhary, Sonal; Romanelli, Paolo
2017-05-01
Connective tissue nevi (CTN) are hamartomas of the dermis, with the 3 main components being collagen, elastin, and proteoglycans. Each subtype can present as a solitary lesion or multiple lesions. They could present as part of systemic diseases or inherited disorders. This article provides a comprehensive literature review of the different types of CTN, their clinical presentations, associations, and treatment options. Treatment options for 56 lesions were reviewed. Fifty-two percent of lesions were present in males, and the age range at the time of presentation was wide (1.6-80 years). Management varied according to CTN subtypes. Most lesions (14) received topical or intralesional treatment with corticosteroids, followed by surgical removal of lesions (12), whereas the remaining lesions were clinically monitored.
NASA Astrophysics Data System (ADS)
Weiersbye-Witkowski, I. M.; Przybylowicz, W. J.; Straker, C. J.; Mesjasz-Przybylowicz, J.
1997-07-01
Genotypes of the Southern African cucurbit, Lagenaria sphaerica, that are resistant to powdery-mildew ( Sphaerotheca fuliginea) exhibit foliar hypersensitive (HS) lesions on inoculation with this fungal pathogen. Elemental distributions across radially symmetrical HS lesions, surrounding unlesioned leaf tissue and uninoculated leaf tissue, were obtained using the true elemental imaging system (Dynamic Analysis) of the NAC Van de Graaff nuclear microprobe. Raster scans of 3 MeV protons were complemented by simultaneous PIXE and BS point analyses. The composition of cellulose (C 6H 10O 5) was used as constant matrix composition for scans, and the sample thickness was found from BS spectra. Si and elements heavier than Ca contributed to matrix composition within HS lesions and the locally elevated Ca raised the limits of detection for some trace metals of interest. In comparison to uninoculated tissue, inoculated tissue was characterised by higher overall concentrations of all measured elements except Cu. Fully developed, 6 day-old HS lesions and the surrounding tissue could be divided into five zones, centred on the fungal infection site. Each zone was characterized by distinct local elemental distributions (either depletion, or accumulation to potentially phytotoxic levels).
Primary Cystic Lesions of the Retrorectal Space: MRI Evaluation and Clinical Assessment.
Dwarkasing, Roy S; Verschuuren, Sylvia I; van Leenders, Geert J L H; Braun, Loes M M; Krestin, Gabriel P; Schouten, W Rudolph
2017-10-01
The purpose of this study was to assess the a priori chance that primary cystic lesions of the retrorectal space are malignant and to investigate MRI characteristics that indicate malignancy. Patients referred to a center for colorectal surgery were recruited from 2000 to 2014. Lesions were proven by clinical assessment and histopathology. MRI was performed at 1.5 T with examinations evaluated by two radiologists. Interobserver agreement was assessed (Cohen kappa) and differences between malignant and benign lesions calculated (Fisher exact test). Twenty-eight patients (22 women, six men; age range, 18-70 years) with 31 lesions were included. Lesions were categorized as tailgut cysts (n = 16, 52%), teratomas (n = 9, 29%), lesions of colorectal origin (n = 4, 13%), or neurogenic lesions (n = 2, 6%). Five patients (18%) had malignant lesions. Colorectal lesions had the highest percentage of malignancy (3/4, 75%). A solid tissue component was found in all five (100%) malignant lesions and two (8%) of the benign lesions, which were both teratomas (p < 0.05). Sensitivity and specificity for malignancy according to the presence of a solid tissue component was 100% (5/5) and 92% (24/26). For unilocularity, multilocularity, debris, septa, and wall thickening, differences were not significant. Interobserver agreement was excellent (κ = 1) for all characteristics except debris (κ = 0.795). The majority of retrorectal cystic lesions are benign. The presence of a solid tissue component should raise suspicion for malignancy.
Bongiorno, Michelle A; Nathan, Neera; Oyerinde, Oyetewa; Wang, Ji-An; Lee, Chyi-Chia Richard; Brown, G Thomas; Moss, Joel; Darling, Thomas N
2017-07-01
Patients with tuberous sclerosis complex (TSC) frequently develop collagenous connective tissue nevi. The prototypical lesion is a large shagreen patch located on the lower back, but some patients only manifest small collagenomas or have lesions elsewhere on the body. The ability to recognize these variable presentations can be important for the diagnosis of TSC. To describe the clinical characteristics of connective tissue nevi on the trunk and extremities of patients with tuberous sclerosis complex. A retrospective analysis of patient medical records and skin photography was performed; 104 adult patients with TSC were enrolled in an observational cohort study that was enriched for those with pulmonary lymphangioleiomyomatosis, and was therefore composed mostly of women (99 women, 5 men). All patients included were examined at the National Institutes of Health (NIH) in Bethesda, Maryland, from 1998 to 2013. Connective tissue nevi were categorized per anatomic location and size. Lesions less than 1 cm in diameter were termed collagenomas. Shagreen patches were characterized as small (1 to <4 cm), medium (4 to <8 cm), and large (≥8 cm). Frequency, anatomic location, size, and histological appearance of connective tissue nevi in patients with TSC. Overall, 58 of 104 patients (median [range] age, 42 [19-70] years) with TSC (56%) had at least 1 connective tissue nevus on the trunk or thighs; of these, 28 of 58 patients (48%) had a solitary lesion, and 30 of 58 patients (52%) had 2 or more lesions. Overall, 120 lesions from 55 patients were classified by size; 46 lesions (38%) were collagenomas; 39 lesions (32%) were small shagreen patches; 21 lesions (18%), medium shagreen patches; and 14 lesions (12%), large shagreen patches. The distribution of lesions was 9% (n = 11), upper back; 29% (n = 35), middle back; 51% (n = 61), lower back; and 11% (n = 13), other locations. All 26 shagreen patches that were analyzed histopathologically had coarse collagen fibers and 24 of 26 stained with Miller elastic stain had decreased elastic fibers. On immunoblot analysis, fibroblasts grown from shagreen patches expressed higher levels of phosphorylated ribosomal protein S6 than paired fibroblasts from normal-appearing skin. Tuberous sclerosis complex-related connective tissue nevi are not limited to the lower back, and occasionally present on the central or upper back, buttocks, or thighs. Elastic fibers are typically decreased. Recognition of these variable presentations can be important for TSC diagnosis.
Periosteal ganglion: a cause of cortical bone erosion.
McCarthy, E F; Matz, S; Steiner, G C; Dorfman, H D
1983-01-01
Three cases of periosteal ganglia of long bones are presented. These lesions are produced by mucoid degeneration and cyst formation of the periosteum to produce external cortical erosion and reactive periosteal new bone. They are not associated with a soft tissue ganglion or an intraosseous lesion. They may radiologically mimic other periosteal lesions or soft tissue neoplasms which erode bone.
Chaturvedi, Abhishek; Gange, Chris; Sahin, Hakan; Chaturvedi, Apeksha
2018-01-01
Mediastinal and paracardiac lesions are usually first diagnosed on a chest radiograph or echocardiogram. Often, a computed tomography is obtained to further delineate these lesions. CT may be suboptimal for evaluation of enhancement characteristics and direct extension into the adjacent mediastinal structures. With its intrinsic superior soft-tissue characterization, magnetic resonance imaging (MRI) can better delineate these lesions, their internal tissue characteristics, and identify adhesion/invasion into adjacent structures. This pictorial essay provides a brief synopsis of the key MRI sequences and their utility in further characterizing mediastinal and paracardiac lesions. PMID:29619281
Paradigms and progress in vocal fold restoration.
Ford, Charles N
2008-09-01
Science advances occur through orderly steps, puzzle-solving leaps, or divergences from the accepted disciplinary matrix that occasionally result in a revolutionary paradigm shift. Key advances must overcome bias, criticism, and rejection. Examples in biological science include use of embryonic stem cells, recognition of Helicobacter pylori in the etiology of ulcer disease, and the evolution of species. Our work in vocal fold restoration reflects these patterns. We progressed through phases of tissue replacement with fillers and biological implants, to current efforts at vocal fold regeneration through tissue engineering, and face challenges of a new "systems biology" paradigm embracing genomics and proteomics.
Nap, Annemiek W; Groothuis, Patrick G; Demir, Ayse Y; Maas, Jacques W M; Dunselman, Gerard A J; de Goeij, Anton F P M; Evers, Johannes L H
2003-01-01
Not all women with patent tubes develop clinically manifest endometriosis. Quality and quantity of endometrium in retrograde menstruation may be the determining factor in the development of the disease. We hypothesize that retrograde shedding of endometrial fragments with preserved integrity facilitates implantation of endometrium in ectopic locations, resulting in endometriotic lesion development. We evaluate the impact of tissue integrity on the success of endometriosis-like lesion development in the chicken embryo chorioallantoic membrane (CAM) model. Menstrual and non-menstrual (cyclic) endometrium were collected by biopsy, and either minced or enzymatically dispersed. Spontaneously shed menstrual effluent was collected by a menstrual cup, and cells and tissue were isolated. We evaluated whether infiltration or lesion formation in the CAM occurred after transplantation of endometrium onto the CAM. Transplantation of biopsied menstrual and cyclic endometrium fragments, and of endometrium fragments >1 mm(3) isolated from menstrual effluent, resulted in lesion formation. Transplantation of endometrial cells isolated from menstrual effluent did not lead to lesion formation. After transplantation of digested biopsied cyclic endometrium, infiltration in the CAM but no lesions were observed. In the CAM assay, integrity of tissue architecture determines success of implantation of human endometrium in ectopic locations.
NASA Astrophysics Data System (ADS)
Charanya, Tauseef; York, Timothy; Bloch, Sharon; Sudlow, Gail; Liang, Kexian; Garcia, Missael; Akers, Walter J.; Rubin, Deborah; Gruev, Viktor; Achilefu, Samuel
2014-12-01
Colitis-associated cancer (CAC) arises from premalignant flat lesions of the colon, which are difficult to detect with current endoscopic screening approaches. We have developed a complementary fluorescence and polarization reporting strategy that combines the unique biochemical and physical properties of dysplasia and cancer for real-time detection of these lesions. Using azoxymethane-dextran sodium sulfate (AOM-DSS) treated mice, which recapitulates human CAC and dysplasia, we show that an octapeptide labeled with a near-infrared (NIR) fluorescent dye selectively identified all precancerous and cancerous lesions. A new thermoresponsive sol-gel formulation allowed topical application of the molecular probe during endoscopy. This method yielded high contrast-to-noise ratios (CNR) between adenomatous tumors (20.6±1.65) and flat lesions (12.1±1.03) and surrounding uninvolved colon tissue versus CNR of inflamed tissues (1.62±0.41). Incorporation of nanowire-filtered polarization imaging into NIR fluorescence endoscopy shows a high depolarization contrast in both adenomatous tumors and flat lesions in CAC, reflecting compromised structural integrity of these tissues. Together, the real-time polarization imaging provides real-time validation of suspicious colon tissue highlighted by molecular fluorescence endoscopy.
NASA Astrophysics Data System (ADS)
Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.
2017-02-01
Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.
Wang, Yearnchee Curtis; Chan, Terence Chee-Hung; Sahakian, Alan Varteres
2018-01-04
Radiofrequency ablation (RFA), a method of inducing thermal ablation (cell death), is often used to destroy tumours or potentially cancerous tissue. Current techniques for RFA estimation (electrical impedance tomography, Nakagami ultrasound, etc.) require long compute times (≥ 2 s) and measurement devices other than the RFA device. This study aims to determine if a neural network (NN) can estimate ablation lesion depth for control of bipolar RFA using complex electrical impedance - since tissue electrical conductivity varies as a function of tissue temperature - in real time using only the RFA therapy device's electrodes. Three-dimensional, cubic models comprised of beef liver, pork loin or pork belly represented target tissue. Temperature and complex electrical impedance from 72 data generation ablations in pork loin and belly were used for training the NN (403 s on Xeon processor). NN inputs were inquiry depth, starting complex impedance and current complex impedance. Training-validation-test splits were 70%-0%-30% and 80%-10%-10% (overfit test). Once the NN-estimated lesion depth for a margin reached the target lesion depth, RFA was stopped for that margin of tissue. The NN trained to 93% accuracy and an NN-integrated control ablated tissue to within 1.0 mm of the target lesion depth on average. Full 15-mm depth maps were calculated in 0.2 s on a single-core ARMv7 processor. The results show that a NN could make lesion depth estimations in real-time using less in situ devices than current techniques. With the NN-based technique, physicians could deliver quicker and more precise ablation therapy.
Jakovljevic, Aleksandar; Knezevic, Aleksandra; Karalic, Danijela; Soldatovic, Ivan; Popovic, Branka; Milasin, Jelena; Andric, Miroslav
2015-08-01
This study aimed to compare the levels of tumour necrosis factor-alpha (TNF-α), interleukin-1 beta (IL-1β) and interleukin-6 (IL-6) between apical periodontitis lesions with different clinical and histological features. Based on clinical data and history of disease, 100 human apical periodontitis lesions were categorised as either asymptomatic or symptomatic lesions. According to histological examination, lesions were divided into periapical granulomas and radicular cysts. Pulp tissues of 25 impacted wisdom teeth were used as controls. Homogenised tissue samples were centrifuged and supernatants were used for the determination of cytokine levels by enzyme-linked immunosorbent assay. Significantly higher levels of IL-1β and IL-6 were found in symptomatic lesions compared with asymptomatic lesions and control tissues (P < 0.001, P < 0.001, respectively). The concentration of IL-1β was significantly higher in radicular cysts compared with periapical granulomas (P = 0.003). Symptomatic lesions, as judged by high local production of IL-1β and IL-6, represent an immunologically active stage of the disease. © 2014 Australian Society of Endodontology.
Carrillo, Celia; Peñarrocha, Miguel; Bagán, José Vicente; Vera, Francisco
2008-08-01
To relate the histologic diagnosis and radiographic size with the prognosis of 70 biopsies obtained via periapical surgery. Seventy biopsies obtained during periapical surgery were histologically analyzed following curettage of the tissue, establishing the diagnosis as either apical granuloma, radicular cyst, or scar tissue. The radiographic size of the lesion (area in mm(2)) before surgery and after 1 year of follow-up was measured. The evolution at 12 months after surgery was evaluated according to the criteria of von Arx and Kurt. A statistical study was made, the inter-variable relationships were studied using analysis of variance with subsequent Tukey testing and calculation of Pearson correlation coefficient. Results indicated that 65.7% of lesions were granulomas, 25.7% scar tissue, and 8.6% cysts. The larger lesions had the worst prognosis. Cysts had the worst evolution at 12 months after surgery, this result being statistically significant. The prognosis for the periapical lesion depended on the type of lesion and its radiographic size, with cysts and larger lesions having the worst evolution.
Ductility dip cracking susceptibility of Inconel Filler Metal 52 and Inconel Alloy 690
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kikel, J.M.; Parker, D.M.
1998-06-01
Alloy 690 and Filler Metal 52 have become the materials of choice for commercial nuclear steam generator applications in recent years. Filler Metal 52 exhibits improved resistance to weld solidification and weld-metal liquation cracking as compared to other nickel-based filler metals. However, recently published work indicates that Filler Metal 52 is susceptible to ductility dip cracking (DDC) in highly restrained applications. Susceptibility to fusion zone DDC was evaluated using the transverse varestraint test method, while heat affected zone (HAZ) DDC susceptibility was evaluated using a newly developed spot-on-spot varestraint test method. Alloy 690 and Filler Metal 52 cracking susceptibility wasmore » compared to the DDC susceptibility of Alloy 600, Filler Metal 52, and Filler Metal 625. In addition, the effect of grain size and orientation on cracking susceptibility was also included in this study. Alloy 690, Filler Metal 82, Filler Metal 52, and Filler Metal 625 were found more susceptible to fusion zone DDC than Alloy 600. Filler Metal 52 and Alloy 690 were found more susceptible to HAZ DDC when compared to wrought Alloy 600, Filler Metal 82 and Filler Metal 625. Filler Metal 52 exhibited the greatest susceptibility to HAZ DDC of all the weld metals evaluated. The base materials were found much more resistant to HAZ DDC in the wrought condition than when autogenously welded. A smaller grain size was found to offer greater resistance to DDC. For weld metal where grain size is difficult to control, a change in grain orientation was found to improve resistance to DDC.« less
Sharma, Rakesh; Kapusetti, Govinda; Bhong, Sayali Yashwant; Roy, Partha; Singh, Santosh Kumar; Singh, Shikha; Balavigneswaran, Chelladurai Karthikeyan; Mahato, Kaushal Kumar; Ray, Biswajit; Maiti, Pralay; Misra, Nira
2017-09-20
Bone cement has found extensive usage in joint arthroplasty over the last 50 years; still, the development of bone cement with essential properties such as high fatigue resistance, lower exothermic temperature, and bioactivity has been an unsolved problem. In our present work, we have addressed all of the mentioned shortcomings of bone cement by reinforcing it with graphene (GR), graphene oxide (GO), and surface-modified amino graphene (AG) fillers. These nanocomposites have shown hypsochromic shifts, suggesting strong interactions between the filler material and the polymer matrix. AG-based nanohybrids have shown greater osteointegration and lower cytotoxicity compared to other nanohybrids as well as pristine bone cement. They have also reduced oxidative stress on cells, resulting in calcification within 20 days of the implantation of nanohybrids into the rabbits. They have significantly reduced the exothermic curing temperature to body temperature and increased the setting time to facilitate practitioners, suggesting that reaction temperature and settling time can be dynamically controlled by varying the concentration of the filler. Thermal stability and enhanced mechanical properties have been achieved in nanohybrids vis-à-vis pure bone cement. Thus, this newly developed nanocomposite can create natural bonding with bone tissues for improved bioactivity, longer sustainability, and better strength in the prosthesis.
Oral and non oral diseases and conditions associated with bad breath.
Migliario, M; Rimondini, L
2011-03-01
The causes of bad breath are numerous and related to conditions dependent or not on oral and general health. The aim of our observational study is the assessment of the simultaneous relationships between halitosis, oral and/or nonoral diseases, and lifestyles using the principal components analysis of categorical data (CATPCA) to identify the main components involved in the detection of the symptom. A sample of 192 patients, who requested general dental examination at the Dental Clinic, participated at the study. Alimentary and voluptuary habits, general health information, drugs assumption, the status of teeth and intraoral medical devices including fillers, lesions of the oral mucosa, tongue coating score (TCS), plaque index (PI), probing bleeding index (PBI) and organoleptic tests were all evaluated. Data were analysed using CATPCA model. A strong relationship between halitosis and plaque, probing bleeding and tongue coating indexes was observed, whereas incongruous fillers, prostheses, systemic pathologies or diet were not clearly associated with halitosis probably because their effects on breath were clinically sheltered by the periodontal condition. The data of our observational study confirm that halitosis is more indicative of tongue coating and periodontal disease, rather than other oral and non oral associated conditions, like systemic pathologies or specific habits of life.
Karunakaran, J. V.; Abraham, Chris Susan; Karthik, A. Kaneesh; Jayaprakash, N.
2017-01-01
Periapical lesions of endodontic origin are common pathological conditions affecting periradicular tissues. Microbial infection of pulpal tissues is primarily responsible for initiation and progression of apical periodontitis. The primary objective of endodontic therapy should be to restore involved teeth to a state of normalcy nonsurgically. Different nonsurgical management techniques, namely, conservative root canal therapy, decompression technique, method using calcium hydroxide, aspiration-irrigation technique, lesion sterilization and tissue repair therapy, active nonsurgical decompression technique, and the apexum procedure have been advocated. New techniques which use drug-loaded injectable scaffolds, simvastatin, and epigallocatechin-3-gallate have been tried. Surgical option should be considered when intra- or extra-radicular infections are persistent. Incidence of nonendodontic periapical lesions has also been reported. An accurate diagnosis of the periapical lesion whether it is of endodontic or nonendodontic origin has to be made. Surgical methods have many disadvantages, and hence should be considered as an option only in the case of failure of nonsurgical techniques. Assessment of healing of periapical lesions has to be done periodically which necessitates a long-term follow-up. Even large periapical lesions and retreatment cases where the lesion is of endodontic origin have been successfully managed nonsurgically with orthograde endodontic therapy. PMID:29284973
NASA Astrophysics Data System (ADS)
Svenson, Robert H.; Marroum, Marie-Claire; Frank, Frank; Selle, Jay G.; Gallagher, John J.; Bou-Saba, George; Seifert, Kathleen T.; Linder, Kathy; Tatsis, George P.
1987-04-01
Canine myocardial lesions of predictable dimensions can be achieved with Nd:YAG laser photocoagulation. These lesions are well demarcated from surrounding normal tissue and heal with homogeneous scar formation. Intraoperative Nd:YAG laser photocoagulation successfully ablated 52 of 55 ventricular tachycardias in 17 patients. Histologic examination of tissues from these arrhythmogenic areas showed differences from lesions produced on canine epicardium. Lesions from the human cases were less predictable and not well circumscribed. These differences are felt to be due to optical inhomogeneities present in diseased, scarred human myocardium, geometric irregularities of the endocardial surface, anatomical constraints on tissue-fiber distance, and the angle of incidence of the beam with the tissue. Modifications of current delivery systems may overcome some of these limitations. Ablation of ventricular tachycardia arising deeper than 4.0 to 6.0 mm. from the irradiated surface may require interstitial probes coupled to the fiberoptic.
Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed
2017-06-01
Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Schmocker, Andreas M.; Khoushabi, Azadeh; Bourban, Pierre-Etienne; Schizas, Constantin; Pioletti, Dominique; Moser, Christophe
2015-03-01
Photopolymerization is a common tool to harden materials initially in a liquid state. A surgeon can directly trigger the solidification of a dental implant or a bone or tissue filler simply by illumination. Traditionally, photopolymerization has been used mainly in dentistry. Over the last decade advances in material development including a wide range of biocompatible gel- and cement-systems open up a new avenue for in-situ photopolymerization. However, at the device level, surgical endoscopic probes are required. We present a miniaturized light probe where a photoactive material can be 1) mixed, pressurized and injected 2) photopolymerized or photoactivated and 3) monitored during the chemical reaction. The device enables surgeries to be conducted through a hole smaller than 1 mm in diameter. Beside basic injection mechanics, the tool consists of an optical fiber guiding the light required for photopolymerization and for chemical analysis. Combining photorheology and fluorescence spectroscopy, the current state of the photopolymerization is inferred and monitored in real time. Biocompatible and highly tuneable Poly-Ethylene-Glycol (PEG) hydrogels were used as the injection material. The device was tested on a model for intervertebral disc replacement. Gels were successfully implanted into a bovine caudal model and mechanically tested in-vitro during two weeks. The photopolymerized gel was evaluated at the tissue level (adherence and mechanical properties of the implant), at the cellular level (biocompatibility and cytotoxicity) and ergonomic level (sterilization procedure and feasibility study). This paper covers the monitoring aspect of the device.
Tirumani, Sree Harsha; Wagner, Andrew J; Tirumani, Harika; Shinagare, Atul B; Jagannathan, Jyothi P; Hornick, Jason L; George, Suzanne; Ramaiya, Nikhil H
2015-06-01
To define the various CT densities of nonlipomatous component of dedifferentiated liposarcoma (DDLPS) and to determine if the rate of growth varies with density. This study identified 60 patients with DDPLS (38 men, 22 women; mean age at diagnosis 59 years, range, 35-82 years) who had one or more resections. CT scan immediately before the surgical resection (presurgery) and up to a maximum of one year before the surgery (baseline) was reviewed by two radiologists to note the density of the nonlipomatous elements and rate of growth during that period. Clinical and histopathological data were extracted from electronic medical records. Rate of growth of various densities was compared using Kruskal-Wallis test. Three distinct densities of the nonlipomatous component were noted: soft tissue density (SD), fluid density (FD), and mixed density (MD). Of 109 lesions on the presurgery scan (SD = 78; MD = 22; FD = 9), scans at baseline were available for 72/109 lesions (SD = 49; MD = 14; FD = 9). Median growth rate/month without treatment, with chemotherapy, and with radiotherapy were 40%, 24%, and 62%, respectively, for SD lesions and 28%, 61%, and 52% for MD lesions. For FD lesions, it was 72% and 35%, respectively, without treatment and with chemotherapy. There was no statistical difference in the rate of growth of various densities. Density changed over time in 8/72 (11%) lesions, including 2/49 SD lesions (to MD), 1/14 MD lesions (to SD), and 5/9 FD lesions (to SD). DDLPS has three distinct CT densities of which soft tissue density is the most common. Despite not being statistically significant, fluid density lesions had rapid growth rate and often converted to soft tissue density in our study.
He, Ming; Cho, Byoung-Uk; Won, Jong Myoung
2016-01-20
A new concept of composite filler was developed by using cellulose nanofibrils (CNF), precipitated calcium carbonate (PCC) and cationic starch (C-starch). In this study, cellulose nanofibrils were utilized in two different ways: a PCC-CNF composite filler and a papermaking additive in sheet forming. The aim was to elucidate their effects on flocculation, filler retention and the strength and optical properties of handsheets. The highest filler retention was obtained by using the PCC-CNF composite filler in paper sheets. The paper filled with the composite fillers had much higher bursting and tensile strengths than conventional PCC loading. It was also found that the paper prepared with PCC-CNF composite fillers became denser with increasing the filler content of paper. Copyright © 2015 Elsevier Ltd. All rights reserved.
Peris-Celda, M; Giannini, C; Diehn, F E; Eckel, L J; Neff, B A; Van Gompel, J J
2018-04-03
Vestibular schwannomas and meningiomas account for the great majority of lesions arising in the cerebellopontine angle (CPA). In this report, we present a case of glioneuronal heterotopia, also known as glioneuronal hamartoma, arising from the VIII cranial nerve, which is an extremely uncommon lesion. Important radiologic and surgical aspects are reviewed, which may help in early recognition and intraoperative decision making when these lesions are encountered. A healthy 29-year-old female presented with intermittent right facial numbness. Magnetic resonance imaging (MRI) showed an incidental minimally enhancing cerebellopontine angle lesion on the right VII-VIII cranial nerve complex. The patient declined serial observation and opted for operative intervention for resection. Intraoperatively, the lesion resembled neural tissue and was continuous with the VIII cranial nerve. Pathological analysis demonstrated mature glioneuronal tissue consistent with hamartomatous brain tissue. The patient maintained normal hearing and facial nerve function after surgery. Radiologic, surgical and pathological characteristics are described. Ectopic glioneuronal tissue of the VIII cranial nerve is a rare non-neoplastic lesion, and should be considered in the differential diagnosis of unusual appearing intracanalicular and cerebellopontine angle lesions. The congenital and benign nature of this entity makes observation a valid option for these cases, although they are so infrequent that they are often presumptively managed as vestibular schwannomas. Attempts to radically resect these lesions may result in higher rates of hearing loss or facial palsy due to their continuity with the cranial nerves. Copyright © 2018 Elsevier Inc. All rights reserved.
Nightingale, K R; Nightingale, R W; Palmeri, M L; Trahey, G E
2000-01-01
The early detection of breast cancer reduces patient mortality. The most common method of breast cancer detection is palpation. However, lesions that lie deep within the breast are difficult to palpate when they are small. Thus, a method of remote palpation, which may allow the detection of small lesions lying deep within the breast, is currently under investigation. In this method, acoustic radiation force is used to apply localized forces within tissue (to tissue volumes on the order of 2 mm3) and the resulting tissue displacements are mapped using ultrasonic correlation based methods. A volume of tissue that is stiffer than the surrounding medium (i.e., a lesion) distributes the force throughout the tissue beneath it, resulting in larger regions of displacement, and smaller maximum displacements. The resulting displacement maps may be used to image tissue stiffness. A finite-element-model (FEM) of acoustic remote palpation is presented in this paper. Using this model, a parametric analysis of the affect of varying tissue and acoustic beam characteristics on radiation force induced tissue displacements is performed. The results are used to evaluate the potential of acoustic remote palpation to provide useful diagnostic information in a clinical setting. The potential for using a single diagnostic transducer to both generate radiation force and track the resulting displacements is investigated.
NASA Astrophysics Data System (ADS)
Taroni, Paola; Paganoni, Anna Maria; Ieva, Francesca; Pifferi, Antonio; Quarto, Giovanna; Abbate, Francesca; Cassano, Enrico; Cubeddu, Rinaldo
2017-01-01
Several techniques are being investigated as a complement to screening mammography, to reduce its false-positive rate, but results are still insufficient to draw conclusions. This initial study explores time domain diffuse optical imaging as an adjunct method to classify non-invasively malignant vs benign breast lesions. We estimated differences in tissue composition (oxy- and deoxyhemoglobin, lipid, water, collagen) and absorption properties between lesion and average healthy tissue in the same breast applying a perturbative approach to optical images collected at 7 red-near infrared wavelengths (635-1060 nm) from subjects bearing breast lesions. The Discrete AdaBoost procedure, a machine-learning algorithm, was then exploited to classify lesions based on optically derived information (either tissue composition or absorption) and risk factors obtained from patient’s anamnesis (age, body mass index, familiarity, parity, use of oral contraceptives, and use of Tamoxifen). Collagen content, in particular, turned out to be the most important parameter for discrimination. Based on the initial results of this study the proposed method deserves further investigation.
A case series associated with different kinds of endo-perio lesions.
Aksel, Hacer; Serper, Ahmet
2014-02-01
Pulpal and periodontal problems are responsible for more than half of the tooth mortality. There are some articles published in the literature about this issue. Many of them are quite old. There has been also lack of knowledge about the effect of endodontic treatment on the periodontal tissue healing and suitable treatment interval between endodontic and periodontal treatments. In this case report, different kinds of endo-perio lesion were treated with sequential endodontic and periodontal treatment. The follow-up radiographs showed complete healing of the hard and soft tissue lesions. The tooth with endo-perio lesions should be evaluated thoroughly in terms of any cracks and fracture, especially furcation areas for a long term prognosis. In this case report, it was showed that 3 months treatment intervals between endodontic treatment and periodontal surgery has no harmful effect on periodontal tissue healing. Key words:Endo-perio lesion, furcation, mandibular molar, bone graft, crack line, treatment interval.
NASA Astrophysics Data System (ADS)
Li, Xiao-kang; Liu, Zhen-guo; Hu, Long; Wang, Yi-bo; Lei, Bing; Huang, Xiang
2017-02-01
Numerical studied on T-joints with three-dimensional four directional (3D4D) braided composite fillers was presented in this article. Compared with conventional unidirectional prepreg fillers, the 3D braided composite fillers have excellent ability to prevent crack from penetrating trigone fillers, which constantly occurred in the conventional fillers. Meanwhile, the 3D braided composite fillers had higher fiber volume fraction and eliminated the fiber folding problem in unidirectional prepreg fillers. The braiding technology and mechanical performance of 3D4D braided fillers were studied. The numerical model of carbon fiber T-joints with 3D4D braided composite fillers was built by finite element analysis software. The damage formation, extension and failing process of T-joints with 3D4D braided fillers under tensile load were investigated. Further investigation was extended to the effect of 3D4D braided fillers with different braiding angles on mechanical behavior of the T-joints. The study results revealed that the filling area was the weakest part of the T-joints where the damage first appeared and the crack then rapidly spread to the glue film around the filling area and the interface between over-laminate and soleplate. The 3D4D braided fillers were undamaged and the braiding angle change induced a little effect on the bearing capacity of T-joints.
NASA Astrophysics Data System (ADS)
Sheet, Debdoot; Karamalis, Athanasios; Kraft, Silvan; Noël, Peter B.; Vag, Tibor; Sadhu, Anup; Katouzian, Amin; Navab, Nassir; Chatterjee, Jyotirmoy; Ray, Ajoy K.
2013-03-01
Breast cancer is the most common form of cancer in women. Early diagnosis can significantly improve lifeexpectancy and allow different treatment options. Clinicians favor 2D ultrasonography for breast tissue abnormality screening due to high sensitivity and specificity compared to competing technologies. However, inter- and intra-observer variability in visual assessment and reporting of lesions often handicaps its performance. Existing Computer Assisted Diagnosis (CAD) systems though being able to detect solid lesions are often restricted in performance. These restrictions are inability to (1) detect lesion of multiple sizes and shapes, and (2) differentiate between hypo-echoic lesions from their posterior acoustic shadowing. In this work we present a completely automatic system for detection and segmentation of breast lesions in 2D ultrasound images. We employ random forests for learning of tissue specific primal to discriminate breast lesions from surrounding normal tissues. This enables it to detect lesions of multiple shapes and sizes, as well as discriminate between hypo-echoic lesion from associated posterior acoustic shadowing. The primal comprises of (i) multiscale estimated ultrasonic statistical physics and (ii) scale-space characteristics. The random forest learns lesion vs. background primal from a database of 2D ultrasound images with labeled lesions. For segmentation, the posterior probabilities of lesion pixels estimated by the learnt random forest are hard thresholded to provide a random walks segmentation stage with starting seeds. Our method achieves detection with 99.19% accuracy and segmentation with mean contour-to-contour error < 3 pixels on a set of 40 images with 49 lesions.
NASA Astrophysics Data System (ADS)
Kumar, Sachin; Raj, Shammy; Sarkar, Kishor; Chatterjee, Kaushik
2016-03-01
Toward preparing strong multi-biofunctional materials, poly(ethylenimine) (PEI) conjugated graphene oxide (GO_PEI) was synthesized using poly(acrylic acid) (PAA) as a spacer and incorporated in poly(ε-caprolactone) (PCL) at different fractions. GO_PEI significantly promoted the proliferation and formation of focal adhesions in human mesenchymal stem cells (hMSCs) on PCL. GO_PEI was highly potent in inducing stem cell osteogenesis leading to near doubling of alkaline phosphatase expression and mineralization over neat PCL with 5% filler content and was ~50% better than GO. Remarkably, 5% GO_PEI was as potent as soluble osteoinductive factors. Increased adsorption of osteogenic factors due to the amine and oxygen containing functional groups on GO_PEI augment stem cell differentiation. GO_PEI was also highly efficient in imparting bactericidal activity with 85% reduction in counts of E. coli colonies compared to neat PCL at 5% filler content and was more than twice as efficient as GO. This may be attributed to the synergistic effect of the sharp edges of the particles along with the presence of the different chemical moieties. Thus, GO_PEI based polymer composites can be utilized to prepare bioactive resorbable biomaterials as an alternative to using labile biomolecules for fabricating orthopedic devices for fracture fixation and tissue engineering.Toward preparing strong multi-biofunctional materials, poly(ethylenimine) (PEI) conjugated graphene oxide (GO_PEI) was synthesized using poly(acrylic acid) (PAA) as a spacer and incorporated in poly(ε-caprolactone) (PCL) at different fractions. GO_PEI significantly promoted the proliferation and formation of focal adhesions in human mesenchymal stem cells (hMSCs) on PCL. GO_PEI was highly potent in inducing stem cell osteogenesis leading to near doubling of alkaline phosphatase expression and mineralization over neat PCL with 5% filler content and was ~50% better than GO. Remarkably, 5% GO_PEI was as potent as soluble osteoinductive factors. Increased adsorption of osteogenic factors due to the amine and oxygen containing functional groups on GO_PEI augment stem cell differentiation. GO_PEI was also highly efficient in imparting bactericidal activity with 85% reduction in counts of E. coli colonies compared to neat PCL at 5% filler content and was more than twice as efficient as GO. This may be attributed to the synergistic effect of the sharp edges of the particles along with the presence of the different chemical moieties. Thus, GO_PEI based polymer composites can be utilized to prepare bioactive resorbable biomaterials as an alternative to using labile biomolecules for fabricating orthopedic devices for fracture fixation and tissue engineering. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06906h
Heller, Debra S; Aisner, Seena C; Fitzhugh, Valerie A; Katava, Gordana; Barrett, Theodore
2013-10-01
The study aimed to report the case of a patient with a polypoid vulvar lesion clinically thought to be an aggressive angiomyxoma. On examination, a 4.0 × 2.0 × 1.5-cm polypoid lesion was seen on the right labium majus. Histopathological findings of the excised mass were consistent with pseudoangiomatous stromal hyperplasia of the vulva Pseudoangiomatous stromal hyperplasia is a lesion of breast tissue but can occur in anogenital mammary-like glands. It must be distinguished from low-grade angiosarcoma.
Effect of filler properties in composite resins on light transmittance characteristics and color.
Arikawa, Hiroyuki; Kanie, Takahito; Fujii, Koichi; Takahashi, Hideo; Ban, Seiji
2007-01-01
The purpose of this investigation was to examine the effect of filler particle size and shape as well as filler content on light transmittance characteristics and color of experimental composite resins. A mixture of 30 mol% Bis-GMA and 70 mol% TEGDMA was prepared as a base monomer and to which a photoinitiator (camphorquinone) and a co-initiator (N,N-dimethylaminoethyl methacrylate) were added. Four different irregular- and spherical-shaped filler types with an average particle size of 1.9-11.1 microm were added to the mixture in three different filler contents of 20, 30, and 40 vol%. Light transmittance characteristics including light diffusion characteristics of the materials were evaluated. Color values and color differences among filler contents of the materials were also determined. Materials containing smaller and irregular-shaped fillers showed higher light transmittance and diffusion angle distribution with a sharper peak, as compared with those containing larger and spherical-shape fillers. It was also found that there was a significant correlation between the specific surface area of fillers and the color difference of the materials containing the fillers. Our results indicated that the shape of filler particles, as well as particle size and filler content, significantly affected the light transmittance characteristics--including light diffusion characteristics--and color of composite resins.
Moon, Youngmin; Han, Jung Hyun; Shin, Sungho; Kim, Yong-Chul; Jeong, Sungho
2016-01-01
By laser induced breakdown spectroscopy (LIBS) analysis of epidermal lesion and dermis tissue pellets of hairless mouse, it is shown that Ca intensity in the epidermal lesion is higher than that in dermis, whereas Na and K intensities have an opposite tendency. It is demonstrated that epidermal lesion and normal dermis can be differentiated with high selectivity either by univariate or multivariate analysis of LIBS spectra with an intensity ratio difference by factor of 8 or classification accuracy over 0.995, respectively. PMID:27231610
Liu, Xiaohang; Zhou, Liangping; Peng, Weijun; Qian, Min
2011-06-01
Post-contrast diffusion-weighted imaging (DWI) is occasionally necessary when the results of the pre-contrast DWI differ from that of the dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), however, the effects of contrast material on DWI image and apparent diffusion coefficient (ADC) values have not been fully examined. To assess whether the administration of gadolinium-DTPA (Gd-DTPA) significantly affects the DWI of prostate lesions or normal tissue at the 3.0 Tesla magnetic resonance imaging (3.0 T MRI). Fifty-one patients with 52 prostate lesions, including 32 prostate cancer (25 in the peripheral zone [PZ] and seven that could not be confidently located) and 20 benign lesions (11 in PZ and nine in central grand [CG]), underwent echo-planar imaging (EPI)-DWI with b values of 0, 1000 s/mm(2) before and after administration of Gd-DTPA at 3.0 T MRI. Regions of interest (ROI) were drawn in all lesions, 42 normal PZ, 44 CG tissue and air to calculate the signal-to-noise ratio (SNR) and ADC values of lesions and normal tissue, and contrast-to-noise ratio (CNR) of lesions for pre- and post-contrast images. Statistical differences between pre- and post-contrast data were assessed by use of a paired t test. No significant differences between pre- and post-contrast images were found in the CNR of lesions and SNR of all the tissue except CG, which showed a statistically significant decline (9.6%, p < 0.0001) in SNR after contrast relative to the pre-contrast images. The post-contrast ADC values were statistically significantly lower than pre-contrast for prostate cancer (0.80 ± 0.11 mm(2)/s Vs 0.89 ± 0.12 mm(2)/s, p < 0.0001) and benign lesions (1.14 ± 0.30 mm(2)/s vs. 1.2 ± 0.29 mm(2)/s, p < 0.0001). No significant differences were detected for normal tissue. The administration of Gd-DTPA can slightly affect the DWI image quality of the prostate and reduce the ADC value of lesions at 3.0T MRI. Applications of post-contrast DWI require caution in interpretation.
Histopathological features of Proteus syndrome.
Hoey, S E H; Eastwood, D; Monsell, F; Kangesu, L; Harper, J I; Sebire, N J
2008-05-01
Proteus syndrome is a rare, sporadic overgrowth disorder for which the underlying genetic defect remains unknown. Although the clinical course is well-described there is no systematic histopathological description of the lesional pathology. To describe the histopathological features encountered in a series of patients with Proteus syndrome from a single centre. Patients with Proteus syndrome who had undergone therapeutic surgical resection or biopsy were identified from a database and the histopathological findings were reviewed, with particular regard to descriptive features of the underlying tissue abnormality. There were 18 surgical specimens from nine patients, median age 4 years (range 1-9), classified into four main categories: soft-tissue swellings (lipomatous lesions), vascular anomalies (vascular malformation and haemangioma), macrodactyly (hamartomatous overgrowth) and others (sebaceous naevus and nonspecific features). In all cases, the clinical features of overgrowth were due to increased amounts of disorganized tissue, indicating a hamartomatous-type defect in which normal tissue constituents were present, but with an abnormal distribution and architecture. Vascular malformations represented a prominent category of lesions, accounting for 50% of the specimens, predominantly comprising lymphatic and lymphovascular malformations. No malignancy or cytological atypia was identified in any case. The histopathological features of lesions resected from children with Proteus syndrome predominantly include hamartomatous mixed connective tissue lesions, benign neoplasms such as lipomata, and lymphatic-rich vascular malformations.
Brooks, Benjamin D.; Sinclair, Kristofer D.; Grainger, David W.; Brooks, Amanda E.
2015-01-01
Nearly 1.3 million total joint replacement procedures are performed in the United States annually, with numbers projected to rise exponentially in the coming decades. Although finite infection rates for these procedures remain consistently low, device-related infections represent a significant cause of implant failure, requiring secondary or revision procedures. Revision procedures manifest several-fold higher infection recurrence rates. Importantly, many revision surgeries, infected or not, require bone void fillers to support the host bone and provide a sufficient tissue bed for new hardware placement. Antibiotic-eluting bone void fillers (ABVF), providing both osteoconductive and antimicrobial properties, represent one approach for reducing rates of orthopedic device-related infections. Using a solvent-free, molten-cast process, a polymer-controlled antibiotic-eluting calcium carbonate hydroxyapatite (HAP) ceramic composite BVF (ABVF) was fabricated, characterized, and evaluated in vivo using a bacterial challenge in a rabbit radial defect window model. ABVF loaded with tobramycin eliminated the infectious burden in rabbits challenged with a clinically relevant strain of Staphylococcus aureus (inoculum as high as 107 CFU). Histological, microbiological, and radiographic methods were used to detail the effects of ABVF on microbial challenge to host bone after 8 weeks in vivo. In contrast to the HAP/BVF controls, which provided no antibiotic protection and required euthanasia 3 weeks post-operatively, tobramycin-releasing ABVF animals showed no signs of infection (clinical, microbiological, or radiographic) when euthanized at the 8-week study endpoint. ABVF sites did exhibit fibrous encapsulation around the implant at 8 weeks. Local antibiotic release from ABVF to orthopedic sites requiring bone void fillers eliminated the periprosthetic bacterial challenge in this 8-week in vivo study, confirming previous in vitro results. PMID:25815727
Glass transition temperature of polymer nano-composites with polymer and filler interactions
NASA Astrophysics Data System (ADS)
Hagita, Katsumi; Takano, Hiroshi; Doi, Masao; Morita, Hiroshi
2012-02-01
We systematically studied versatile coarse-grained model (bead spring model) to describe filled polymer nano-composites for coarse-grained (Kremer-Grest model) molecular dynamics simulations. This model consists of long polymers, crosslink, and fillers. We used the hollow structure as the filler to describe rigid spherical fillers with small computing costs. Our filler model consists of surface particles of icosahedra fullerene structure C320 and a repulsive force from the center of the filler is applied to the surface particles in order to make a sphere and rigid. The filler's diameter is 12 times of beads of the polymers. As the first test of our model, we study temperature dependence of volumes of periodic boundary conditions under constant pressures through NPT constant Andersen algorithm. It is found that Glass transition temperature (Tg) decrease with increasing filler's volume fraction for the case of repulsive interaction between polymer and fillers and Tg weakly increase for attractive interaction.
NASA Astrophysics Data System (ADS)
Mastalygina, E. E.; Popov, A. A.; Pantyukhov, P. V.
2017-06-01
The paper is devoted to investigation of deterioration of natural fillers and polyethylene composites on their basis (polyethylene/filler=70/30) due to the action of mold fungi. The fillers chemical composition, dimensional parameters and biodegradability have been analyzed as factors exert a considerable impact on composite materials biodeterioration. It has been found that the principal factor determining the biodeterioration of polyethylene/filler composites by mold fungi is chemical composition of a filler and, in turn, its biodegradability. The excess of holocellulose content over lignin content and high protein content in a filler are able to induce biofouling of the polymeric composite materials. The presence of soluble and easy hydrolysed fraction in a filler increases its availability in a polymeric matrix. According to the study results, most effective natural fillers as additives stimulating polyethylene composites biodegradability are milled straw of seed flax and hydrolyzed keratin of bird’s feather.
Dubey, Jitender P.; Ferreira, Leandra R.; Alsaad, Mohammad; Verma, Shiv K.; Alves, Derron A.; Holland, Gary N.; McConkey, Glenn A.
2016-01-01
Background The protozoan parasite Toxoplasma gondii is one of the most widely distributed and successful parasites. Toxoplasma gondii alters rodent behavior such that infected rodents reverse their fear of cat odor, and indeed are attracted rather than repelled by feline urine. The location of the parasite encysted in the brain may influence this behavior. However, most studies are based on the highly susceptible rodent, the mouse. Methodology/Principal Findings Latent toxoplasmosis was induced in rats (10 rats per T. gondii strains) of the same age, strain, and sex, after oral inoculation with oocysts (natural route and natural stage of infection) of 11 T. gondii strains of seven genotypes. Rats were euthanized at two months post inoculation (p.i.) to investigate whether the parasite genotype affects the distribution, location, tissue cyst size, or lesions. Tissue cysts were enumerated in different regions of the brains, both in histological sections as well in saline homogenates. Tissue cysts were found in all regions of the brain. The tissue cyst density in different brain regions varied extensively between rats with many regions highly infected in some animals. Overall, the colliculus was most highly infected although there was a large amount of variability. The cerebral cortex, thalamus, and cerebellum had higher tissue cyst densities and two strains exhibited tropism for the colliculus and olfactory bulb. Histologically, lesions were confined to the brain and eyes. Tissue cyst rupture was frequent with no clear evidence for reactivation of tachyzoites. Ocular lesions were found in 23 (25%) of 92 rat eyes at two months p.i. The predominant lesion was focal inflammation in the retina. Tissue cysts were seen in the sclera of one and in the optic nerve of two rats. The choroid was not affected. Only tissue cysts, not active tachyzoite infections, were detected. Tissue cysts were seen in histological sections of tongue of 20 rats but not in myocardium and leg muscle. Conclusion/Significance This study reevaluated in depth the rat model of toxoplasmosis visualizing cyst rupture and clarified many aspects of the biology of the parasite useful for future investigations. PMID:27228262
Enayati, Mohammad Saied; Behzad, Tayebeh; Sajkiewicz, Pawel; Rafienia, Mohammad; Bagheri, Rouhollah; Ghasemi-Mobarakeh, Laleh; Kolbuk, Dorota; Pahlevanneshan, Zari; Bonakdar, Shahin H
2018-04-01
The article is focused on the role of nanohydroxy apatite (nHAp) and cellulose nanofibers (CNFs) as fillers in the electrospun poly (vinyl alcohol) (ES-PVA) nanofibers for bone tissue engineering (TE). Fibrous scaffolds of PVA, PVA/nHAp (10 wt.%), and PVA/nHAp(10 wt.%)/CNF(3 wt.%) were successfully fabricated and characterized. Tensile test on electrospun PVA/nHAp10 and PVA/nHAp10/CNF3 revealed a three-fold and seven-fold increase in modulus compared with pure ES-PVA (45.45 ± 4.77). Although, nanofiller loading slightly reduced the porosity percentage, all scaffolds had porosity higher than 70%. In addition, contact angle test proved the great hydrophilicity of scaffolds. The presence of fillers reduced in vitro biodegradation rate in PBS while accelerates biomineralization in simulated body fluid (SBF). Furthermore, cell viability, cell attachment, and functional activity of osteoblast MG-63 cells were studied on scaffolds showing higher cellular activity for scaffolds with nanofillers. Generally, the obtained results confirm that the 3-componemnt fibrous scaffold of PVA/nHAp/CNF has promising potential in hard TE. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1111-1120, 2018. © 2018 Wiley Periodicals, Inc.
Marmur, Ellen S; Al Quran, Hanadi; De Sa Earp, Ana Paula; Yoo, Jane Y
2009-12-01
The process of skin aging is not limited to the face but involves every part of the body, including the hands. A common manifestation of aging of the hands is the loss of volume, which occurs as the skin loses its subcutaneous fat. Injectable dermal fillers have surfaced as a popular method to address such deficiencies. To report the use of calcium hydroxylapatite (CaHA) to address lost volume. Five female subjects with soft tissue deficiency of the dorsa of the hands were enrolled at Mount Sinai Medical Center. A solution of CaHA with 2% lidocaine in amounts of 0.3 to 1.0 mL was injected interdigitally at each of three to five insertion sites; the sites were massaged and molded up to three times to ensure an optimal cosmetic end point. Subjects were seen for a follow-up visit after 1, 4, 16, and 24 weeks. With a single injection, all subjects reached their correction goals without requiring any touch-ups. At the 24-week visit, the subjects retained the filling effect, with no adverse events and high patient satisfaction. CaHA, a new, easily injectable, safe dermal filler, has emerged as an excellent option for soft tissue augmentation in aging hands.
Wound repair in rat urinary bladder following electrocautery or holmium laser incision
NASA Astrophysics Data System (ADS)
Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.
1999-06-01
Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.
Direct measurement of the lethal isotherm for radiofrequency ablation of myocardial tissue.
Wood, Mark; Goldberg, Scott; Lau, Melissa; Goel, Aneesh; Alexander, Daniel; Han, Frederick; Feinstein, Shawn
2011-06-01
The lethal isotherm for radiofrequency catheter ablation of cardiac myocardium is widely accepted to be 50°C, but this has not been directly measured. The purpose of this study was to directly measure the tissue temperature at the edge of radiofrequency lesions in real time using infrared thermal imaging. Fifteen radiofrequency lesions of 6 to 240 seconds in duration were applied to the left ventricular surface of isolated perfused pig hearts. At the end of radiofrequency delivery, a thermal image of the tissue surface was acquired with an infrared camera. The lesion was then stained and an optical image of the lesion was obtained. The thermal and optical images were electronically merged to allow determination of the tissue temperature at the edge of the lesion at the end of radiofrequency delivery. By adjusting the temperature overlay display to conform with the edge of the radiofrequency lesion, the lethal isotherm was measured to be 60.6°C (interquartile ranges, 59.7° to 62.4°C; range, 58.1° to 64.2°C). The areas encompassed by the lesion border in the optical image and the lethal isotherm in the thermal image were statistically similar and highly correlated (Spearman ρ=0.99, P<0.001). The lethal isotherm temperature was not related to the duration of radiofrequency delivery or to lesion size (both P>0.64). The areas circumscribed by 50°C isotherms were significantly larger than the areas of the lesions on optical imaging (P=0.002). By direct measurement, the lethal isotherm for cardiac myocardium is near 61°C for radiofrequency energy deliveries <240 seconds in duration. A 50°C isotherm overestimates lesion size. Accurate knowledge of the lethal isotherm for radiofrequency ablation is important to clinical practice as well as mathematical modeling of radiofrequency lesions.
Multi-depth fractionated aesthetic ultrasound surgery
NASA Astrophysics Data System (ADS)
Slayton, Michael H.; Lyke, Stephanie; Barthe, Peter G.
2017-03-01
Objective: Aesthetic ultrasound surgery provides the ability to treat at precise, clinically relevant depths with varied lesion size. This represents a major advantage compared to cosmetic laser and RF based energy sources. We present results of pre-clinical and clinical research aimed at establishing the feasibility of three-dimensional fractional deposition of focused ultrasound energy in the first 3mm of skin. Conformal thermal lesions were created in ex-vivo porcine muscle and live human skin in a variety of depths and geometries. Gross pathology demonstrating a three-dimensional pattern of non-intersecting lesions was micro- photographed and characterized in porcine tissue, and followed up to thirty days post treatment in human tissue. Methods: Image/treat transducers from 7.5 to 10 MHz, focal depths of 1 to 3 mm, and energies of 160 to 300 mJ were used to lay down a three-dimensional pattern of non-intersecting thermal lesions in freshly excised porcine muscle tissue. Human skin was treated in vivo at 120 to 360 mJ per lesion. Results were photographed immediately post-treatment and followed up to 30 days. Results: Porcine tissue lesion geometry was measured. Average lesion dimensions approximated by a sphere ranged from 360 micron (±19%) to 520 micron (±23%) varying with the energy settings. Measured depth and distance between the thermal lesions were within ±13% of the focal depth and lesion spacing. In human skin all lesions for all energy settings were completely resolved during the follow-up period. At lower energy settings of 120 mJ and 160 mJ lesions were completely resolved by day 2. Mild erythema and localized swelling were the only transient side effects and resolved within 48 hours or less. Conclusions: In conclusion, skin may be successfully treated in a three-dimensional fractionated manner with predictable and precise deposition of thermal damage. In vivo results demonstrate tolerability and fast resolution with minimal side effects.
Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?
Storm, Andrew C; Lee, Linda S
2016-01-01
The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584
Optical coherence tomography for image-guided dermal filler injection and biomechanical evaluation
NASA Astrophysics Data System (ADS)
Singh, Manmohan; Wang, Shang; Yee, Richard W.; Han, Zhaolong; Aglyamov, Salavat R.; Larin, Kirill V.
2017-02-01
Dermal fillers are a very popular anti-ag ing treatment with estimated sales in the billions of dollars and millions of procedures performed. As the aging population continues to grow, these figures are only e xpected to increase. Dermal fillers have various compositions depending on their intended applicati on. Reactions to dermal fillers can be severe, such as ischemic events and filler migration to the eyes. Howe ver, these adverse reactions are rare. Nevertheless, the capability to perform imag e-guided filler injections would minimize th e risk of such reacti ons. In addition, the biomechanical properties of various fillers have been evalua ted, but there has been no investigation on the effects of filler on the biomechanical properties of skin. In this work, we utilize optical cohe rence tomography (OCT) for visualizing dermal filler injections with micrometer-scale sp atial resolution. In addition, we utilize noncontact optical coherence elastography (OCE) to quantify the changes in the biomechan ical properties of pig skin after the dermal filler injections. OCT was successfully able to visualize the dermal filler injecti on process, and OCE showed that the viscoelasticity of the pig skin was increased locally at the filler injection sites. OCT may be able to provide real-time image guidance in 3D, and when combined with functional OCT techniques such as optical microangiography, could be used to avoid blood vessels during the injection.
A regression analysis of filler particle content to predict composite wear.
Jaarda, M J; Wang, R F; Lang, B R
1997-01-01
It has been hypothesized that composite wear is correlated to filler particle content. There is a paucity of research to substantiate this theory despite numerous projects evaluating the correlation. The purpose of this study was to determine whether a linear relationship existed between composite wear and filler particle content of 12 composites. In vivo wear data had been previously collected for the 12 composites and served as basis for this study. Scanning electron microscopy and backscatter electron imaging were combined with digital imaging analysis to develop "profile maps" of the filler particle composition of the composites. These profile maps included eight parameters: (1) total number of filler particles/28742.6 microns2, (2) percent of area occupied by all of the filler particles, (3) mean filler particle size, (4) percent of area occupied by the matrix, (5) percent of area occupied by filler particles, r (radius) 1.0 < or = micron, (6) percent of area occupied by filler particles, r = 1.0 < or = 4.5 microns, (7) percent of area occupied by filler particles, r = 4.5 < or = 10 microns, and (8) percent of area occupied by filler particles, r > 10 microns. Forward stepwise regression analyses were used with composite wear as the dependent variable and the eight parameters as independent variables. The results revealed a linear relationship between composite wear and the filler particle content. A mathematical formula was developed to predict composite wear.
Hardness of model dental composites - the effect of filler volume fraction and silanation.
McCabe, J F; Wassell, R W
1999-05-01
The relationship between structure and mechanical properties for dental composites has often proved difficult to determine due to the use of commercially available materials having a number of differences in composition i.e. different type of resin, different type of filler, etc. This makes a scientific study of any one variable such as filler content difficult if not impossible. In the current study it was the aim to test the hypothesis that hardness measurements of dental composites could be used to monitor the status of the resin-filler interface and to determine the efficacy of any particle silanation process. Ten model composites formulated from a single batch of resin and containing a common type of glass filler were formulated to contain varying amounts of filler. Some materials contained silanated filler, others contained unsilanated filler. Specimens were prepared and stored in water and hardness (Vickers') was determined at 24 h using loads of 50, 100, 200 and 300 g. Composites containing silanated fillers were significantly harder than materials containing unsilanated fillers. For unsilanated products hardness was independent of applied load and in this respect they behaved like homogeneous materials. For composites containing silanated fillers there was a marked increase in measured hardness as applied load was increased. This suggests that the hardness-load profile could be used to monitor the status of the resin-filler interface. Copyright 1999 Kluwer Academic Publishers
Characterizing lesions in corals from American Samoa
NASA Astrophysics Data System (ADS)
Work, T. M.; Rameyer, R. A.
2005-11-01
The study of coral disease has suffered from an absence of systematic approaches that are commonly used to determine causes of diseases in animals. There is a critical need to develop a standardized and portable nomenclature for coral lesions in the field and to incorporate more commonly available biomedical tools in coral disease surveys to determine the potential causes of lesions in corals. We characterized lesions in corals from American Samoa based on gross and microscopic morphology and classified them as discoloration, growth anomalies, or tissue loss. The most common microscopic finding in corals manifesting discoloration was the depletion of zooxanthellae, followed by necrosis, sometimes associated with invasive algae or fungi. The most common microscopic lesion in corals manifesting tissue loss was cell necrosis often associated with algae, fungi, or protozoa. Corals with growth anomaly had microscopic evidence of hyperplasia of gastrovascular canals, followed by necrosis associated with algae or metazoa (polychaete worms). Several species of apparently normal corals also had microscopic changes, including the presence of bacterial aggregates or crustacea in tissues. A single type of gross lesion (e.g., discoloration) could have different microscopic manifestations. This phenomenon underlines the importance of using microscopy to provide a more systematic description of coral lesions and to detect potential pathogens associated with these lesions.
Jo, J A; Fang, Q; Papaioannou, T; Qiao, J H; Fishbein, M C; Dorafshar, A; Reil, T; Baker, D; Freischlag, J; Marcu, L
2004-01-01
This study investigates the ability of new analytical methods of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) data to characterize tissue in-vivo, such as the composition of atherosclerotic vulnerable plaques. A total of 73 TR-LIFS measurements were taken in-vivo from the aorta of 8 rabbits, and subsequently analyzed using the Laguerre deconvolution technique. The investigated spots were classified as normal aorta, thin or thick lesions, and lesions rich in either collagen or macrophages/foam-cells. Different linear and nonlinear classification algorithms (linear discriminant analysis, stepwise linear discriminant analysis, principal component analysis, and feedforward neural networks) were developed using spectral and TR features (ratios of intensity values and Laguerre expansion coefficients, respectively). Normal intima and thin lesions were discriminated from thick lesions (sensitivity >90%, specificity 100%) using only spectral features. However, both spectral and time-resolved features were necessary to discriminate thick lesions rich in collagen from thick lesions rich in foam cells (sensitivity >85%, specificity >93%), and thin lesions rich in foam cells from normal aorta and thin lesions rich in collagen (sensitivity >85%, specificity >94%). Based on these findings, we believe that TR-LIFS information derived from the Laguerre expansion coefficients can provide a valuable additional dimension for in-vivo tissue characterization.
Characterizing lesions in corals from American Samoa
Work, Thierry M.; Rameyer, Robert A.
2005-01-01
The study of coral disease has suffered from an absence of systematic approaches that are commonly used to determine causes of diseases in animals. There is a critical need to develop a standardized and portable nomenclature for coral lesions in the field and to incorporate more commonly available biomedical tools in coral disease surveys to determine the potential causes of lesions in corals. We characterized lesions in corals from American Samoa based on gross and microscopic morphology and classified them as discoloration, growth anomalies, or tissue loss. The most common microscopic finding in corals manifesting discoloration was the depletion of zooxanthellae, followed by necrosis, sometimes associated with invasive algae or fungi. The most common microscopic lesion in corals manifesting tissue loss was cell necrosis often associated with algae, fungi, or protozoa. Corals with growth anomaly had microscopic evidence of hyperplasia of gastrovascular canals, followed by necrosis associated with algae or metazoa (polychaete worms). Several species of apparently normal corals also had microscopic changes, including the presence of bacterial aggregates or crustacea in tissues. A single type of gross lesion (e.g., discoloration) could have different microscopic manifestations. This phenomenon underlines the importance of using microscopy to provide a more systematic description of coral lesions and to detect potential pathogens associated with these lesions.
21 CFR 888.3045 - Resorbable calcium salt bone void filler device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...
21 CFR 888.3045 - Resorbable calcium salt bone void filler device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...
21 CFR 888.3045 - Resorbable calcium salt bone void filler device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...
21 CFR 888.3045 - Resorbable calcium salt bone void filler device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...
21 CFR 888.3045 - Resorbable calcium salt bone void filler device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Resorbable calcium salt bone void filler device... salt bone void filler device. (a) Identification. A resorbable calcium salt bone void filler device is... entitled “Class II Special Controls Guidance: Resorbable Calcium Salt Bone Void Filler Device; Guidance for...
Aluminum Lithium Alloy 2195 Fusion Welding Improvements with New Filler Wire
NASA Technical Reports Server (NTRS)
Russell, Carolyn; Bjorkman, Gerry; McCool, Carolyn (Technical Monitor)
2000-01-01
A viewgraph presentation outlines NASA Marshall Space Flight Center, Lockheed Martin Michoud Space Systems, and McCook Metals' development an aluminum-copper weld filler wire for fusion welding 2195 aluminum lithium. The aluminum-copper based weld filler wire has been identified as B218, which is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The Super Lightweight External Tank for the NASA Space Shuttle Program consists of 2195 welded with 4043 aluminum-silicon weld filler wire. The B218 filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties. An initial characterization of the B218 weld filler wire was performed consisting of initial weld and repair weld evaluation comparing B218 and 4043. The testing involved room temperature and cryogenic tensile testing along with fracture toughness testing. B218 weld filler wire proved to produce enhanced initial and repair weld tensile and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding 2195 and other aluminum lithium alloys over 4043.
The application of diode laser in the treatment of oral soft tissues lesions. A literature review.
Ortega-Concepción, Daniel; Cano-Durán, Jorge A; Peña-Cardelles, Juan-Francisco; Paredes-Rodríguez, Víctor-Manuel; González-Serrano, José; López-Quiles, Juan
2017-07-01
Since its appearance in the dental area, the laser has become a treatment of choice in the removal of lesions in the oral soft tissues, due to the numerous advantages they offer, being one of the most used currently the diode laser. The aim of this review was to determine the efficacy and predictability of diode laser as a treatment of soft tissue injuries compared to other surgical methods. A literature review of articles published in PubMed/MEDLINE, Scopus and the Cochrane Library databases between 2007 and 2017 was performed. "Diode laser", "soft tissue", "oral cavity" and "oral surgery" were employed for the search strategy. Only articles published English or Spanish were selected. The diode laser is a minimally invasive technology that offers great advantages, superior to those of the conventional scalpel, such as reduction of bleeding, inflammation and the lower probability of scars. Its effectiveness is comparable to that of other types of lasers, in addition to being an option of lower cost and greater ease of use. Its application in the soft tissues has been evaluated, being a safe and effective method for the excision of lesions like fibromas, epulis fissuratum and the accomplishment of frenectomies. The diode laser can be used with very good results for the removal of lesions in soft tissues, being used in small exophytic lesions due to their easy application, adequate coagulation, no need to suture and the slightest inflammation and pain. Key words: Diode laser, soft tissues, oral cavity, oral surgery.
NASA Technical Reports Server (NTRS)
Turner, Travis L. (Inventor); Kidd, Reggie T. (Inventor); Lockard, David P (Inventor); Khorrami, Mehdi R. (Inventor); Streett, Craig L. (Inventor); Weber, Douglas Leo (Inventor)
2016-01-01
A slat cove filler is utilized to reduce airframe noise resulting from deployment of a leading edge slat of an aircraft wing. The slat cove filler is preferably made of a super elastic shape memory alloy, and the slat cove filler shifts between stowed and deployed shapes as the slat is deployed. The slat cove filler may be configured such that a separate powered actuator is not required to change the shape of the slat cove filler from its deployed shape to its stowed shape and vice-versa. The outer contour of the slat cove filler preferably follows a profile designed to maintain accelerating flow in the gap between the slat cove filler and wing leading edge to provide for noise reduction.
Multispectral detection of cutaneous lesions using spectroscopy and microscopy approaches
NASA Astrophysics Data System (ADS)
Borisova, E.; Genova-Hristova, Ts.; Troyanova, P.; Pavlova, E.; Terziev, I.; Semyachkina-Glushkovskaya, O.; Lomova, M.; Genina, E.; Stanciu, G.; Tranca, D.; Avramov, L.
2018-02-01
Autofluorescence, diffuse-reflectance and transmission spectral, and microscopic measurements were made on different cutaneous neoplastic lesions, namely basal cell carcinoma, squamous cell carcinoma, malignant melanoma, and dysplastic and benign lesions related. Spectroscopic measurements were made on ex vivo tissue samples, and confocal microscopy investigations were made on thin tissue slices. Fluorescence spectra obtained reveal statistically significant differences between the different benign, dysplastic and malignant lesions by the level of emission intensity, as well by spectral shape, which are fingerprints applicable for differentiation algorithms. In reflectance mode the most significant differences are related to the influence of skin pigments - melanin and hemoglobin. Transmission spectroscopy mode gave complementary optical properties information about the tissue samples investigated to that one of reflectance and absorption spectroscopy. Using autofluorescence detection of skin lesions we obtain very good diagnostic performance for distinguishing of nonmelanoma lesions. Using diffuse reflectance and transmission spectroscopy we obtain significant tool for pigmented pathologies differentiation, but it is a tool with moderate sensitivity for non-melanoma lesions detection. One could rapidly increase the diagnostic accuracy of the received combined "optical biopsy" method when several spectral detection techniques are applied in common algorithm for lesions' differentiation. Specific spectral features observed in each type of lesion investigated on micro and macro level would be presented and discussed. Correlation between the spectral data received and the microscopic features observed would be discussed in the report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jen, M; Johnson, J; Hou, P
Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR,more » 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients with brain tumors.« less
Balian, S C; Ribeiro, P; Vasconcellos, S A; Pinheiro, S R; Ferreira Neto, J S; Guerra, J L; Xavier, J G; Morais, Z M; Telles, M A
1997-08-01
As the occurrence of tuberculosis lymphadenitis in swine constitutes a public health risk, especially in immunosuppressed individuals, the distribution of tuberculoid lesions and the presence of microbacteria in lymph nodes and hepatic and muscular tissue in swine for slaughter, in the State of S. Paulo, SP (Brazil), in the period from 1993 to 1994, were studied. MATERIAL E METHOD: Tuberculous lesions in 60 carcasses of swine, slaughtered at abattoirs during the period 1993-1994, were studied. When macroscopic lesions were observed, a representative sampling of lymph nodes, hepatic and muscular tissues (masseter and diaphragm) were examined using histopathological and microbacterial isolation techniques. The macroscopic lesions were found predominantly in mesenteric lymph nodes. The MAI Complex (M.avium-intracellulare) was isolated mainly in the carcass group that showed lesions and was not found in the control group. Microorganisms of the MAI Complex were not isolated from hepatic and muscular tissues. No clear relationship between the type of mycobacteria isolated and the macroscopic lesions observed during the carcass inspection was found.
Multiple high-intensity focused ultrasound probes for kidney-tissue ablation.
Häcker, Axel; Chauhan, Sunita; Peters, Kristina; Hildenbrand, Ralf; Marlinghaus, Ernst; Alken, Peter; Michel, Maurice Stephan
2005-10-01
To investigate kidney-tissue ablation by high-intensity focused ultrasound (HIFU) using multiple and single probes. Ultrasound beams (1.75 MHz) produced by a piezoceramic element (focal distance 80 mm) were focused at the center of renal parenchyma. One of the three probes (mounted on a jig) could also be used for comparison with a single probe at comparable power ratings. Lesion dimensions were examined in perfused and unperfused ex vivo porcine kidneys at different power levels (40, 60, and 80 W) and treatment times (4, 6, and 8 seconds). At identical power levels, the lesions induced by multiple probes were larger than those induced by a single probe. Lesion size increased with increasing pulse duration and generator power. The sizes and shapes of the lesions were predictably repeatable in all samples. Lesions in perfused kidneys were smaller than those in unperfused kidneys. Ex vivo, kidney-tissue ablation by means of multiple HIFU probes offers significant advantages over single HIFU probes in respect of lesion size and formation. These advantages need to be confirmed by tests in vivo at higher energy levels.
Does filler database size influence identification accuracy?
Bergold, Amanda N; Heaton, Paul
2018-06-01
Police departments increasingly use large photo databases to select lineup fillers using facial recognition software, but this technological shift's implications have been largely unexplored in eyewitness research. Database use, particularly if coupled with facial matching software, could enable lineup constructors to increase filler-suspect similarity and thus enhance eyewitness accuracy (Fitzgerald, Oriet, Price, & Charman, 2013). However, with a large pool of potential fillers, such technologies might theoretically produce lineup fillers too similar to the suspect (Fitzgerald, Oriet, & Price, 2015; Luus & Wells, 1991; Wells, Rydell, & Seelau, 1993). This research proposes a new factor-filler database size-as a lineup feature affecting eyewitness accuracy. In a facial recognition experiment, we select lineup fillers in a legally realistic manner using facial matching software applied to filler databases of 5,000, 25,000, and 125,000 photos, and find that larger databases are associated with a higher objective similarity rating between suspects and fillers and lower overall identification accuracy. In target present lineups, witnesses viewing lineups created from the larger databases were less likely to make correct identifications and more likely to select known innocent fillers. When the target was absent, database size was associated with a lower rate of correct rejections and a higher rate of filler identifications. Higher algorithmic similarity ratings were also associated with decreases in eyewitness identification accuracy. The results suggest that using facial matching software to select fillers from large photograph databases may reduce identification accuracy, and provides support for filler database size as a meaningful system variable. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Summaries of Research - Fiscal Year 1985.
1986-01-01
emergencies, not trauma-related, 2) diagnosis of dental emergencies, trauma-related, 3) differential diagnosis of soft tissue lesions, 4) definitions of terms...on 49 different soft tissue lesions. Preliminary validation was accomplished by a variety of dentists who input over 200 simulated emergencies. The...non-specific opsonin, that promotes adhesion of fibroblasts to collagen, and influences the attachment of bacteria to soft tissues . As a first step
Dill, Alisa; Letra, Ariadne; de Souza, Letıcia Chaves; Yadlapati, Mamatha; Biguetti, Claudia Cristina; Garlet, Gustavo Pompermaier; Vieira, Alexandre R.; Silva, Renato Menezes
2017-01-01
Introduction It has been proposed that individual genetic predisposition may contribute to persistent apical periodontitis. Cytokines are associated with levels of inflammation and are involved in caries, pulpal, and periapical tissue destruction. We hypothesized that polymorphisms in cytokine genes may contribute to an individual’s increased susceptibility to apical tissue destruction in response to deep carious lesions. Methods Subjects with deep carious lesions, with or without periapical lesions (≥ 3 mm) were recruited at the University of Pittsburgh and the University of Texas at Houston. Genomic DNA samples of 316 patients were sorted into 2 groups: 136 cases with deep carious lesions and periapical lesions (cases), and 180 cases with deep carious lesions but no periapical lesions (controls). Nine single nucleotide polymorphisms in IL1B, IL6, TNF, RANK, RANKL and OPG genes were selected for genotyping. Genotypes were generated by endpoint analysis using Taqman chemistry in a real-time polymerase chain reaction instrument. Allele and genotype frequencies were compared among cases and controls using PLINK program. Ninety-three human periapical granulomas and 24 healthy periodontal ligament tissues collected post-operatively were used for mRNA expression analyses of IL1B. Results A SNP in IL1B (rs1143643) showed allelic (P=0.02) and genotypic (P=0.004) association with cases of deep caries and periapical lesions. We also observed altered transmission of IL1B marker haplotypes (P = 0.02) in these individuals. IL1B was highly expressed in granulomas (P<0.001). Conclusions Variations in IL1B may be associated with periapical lesion formation in individuals with untreated deep carious lesions. Future studies could help predict host susceptibility to developing periapical lesions. PMID:25476976
The impact of fillers on lineup performance.
Wetmore, Stacy A; McAdoo, Ryan M; Gronlund, Scott D; Neuschatz, Jeffrey S
2017-01-01
Filler siphoning theory posits that the presence of fillers (known innocents) in a lineup protects an innocent suspect from being chosen by siphoning choices away from that innocent suspect. This mechanism has been proposed as an explanation for why simultaneous lineups (viewing all lineup members at once) induces better performance than showups (one-person identification procedures). We implemented filler siphoning in a computational model (WITNESS, Clark, Applied Cognitive Psychology 17:629-654, 2003), and explored the impact of the number of fillers (lineup size) and filler quality on simultaneous and sequential lineups (viewing lineups members in sequence), and compared both to showups. In limited situations, we found that filler siphoning can produce a simultaneous lineup performance advantage, but one that is insufficient in magnitude to explain empirical data. However, the magnitude of the empirical simultaneous lineup advantage can be approximated once criterial variability is added to the model. But this modification works by negatively impacting showups rather than promoting more filler siphoning. In sequential lineups, fillers were found to harm performance. Filler siphoning fails to clarify the relationship between simultaneous lineups and sequential lineups or showups. By incorporating constructs like filler siphoning and criterial variability into a computational model, and trying to approximate empirical data, we can sort through explanations of eyewitness decision-making, a prerequisite for policy recommendations.
Gollapudi, Prakash Rao; Mohammed, Imran; Pittala, Sandeep R; Kotha, Arjun Reddy; Reddycherla, Naga Raju; Ginjupally, Dhanunjaya Rao
2018-04-01
Fluorescein sodium is one of the fluorophores that is used in the resection of intracranial lesions. It is commonly used along with a customized microscope, which is expensive and not available universally. In this study, we describe a simple, inexpensive method for better visualization of intracranial and spinal cord lesions with fluorescein. After a test dose, 20 mg/kg of fluorescein sodium was administered intravenously at the time of intubation. A blue light source was used before resection for precise localization of the intracranial lesions after durotomy. Most of the resection was done under the white light, while the blue light was used intermittently to delineate the pathologic tissue from the normal tissue and to ensure safe maximal resection. The intensity of fluorescein staining under white light and blue light was noted. The study comprised 40 cases of gliomas, meningiomas, abscesses, spinal cord tumors, and cerebellopontine angle lesions. Thirty-five lesions showed good fluorescence under the blue light, which helped us achieve better resection of the pathologic lesions. Fluorescein sodium is a safe dye; it can be used to aid in precise localization and safe maximal resection of the pathologic tissue with the help of a blue light source at any center with challenged resources. The blue light enhances the fluorescence and visualization of the pathologic tissue, and this technique can be adopted by any surgeon without much difficulty even with a basic neurosurgical setup. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Luo, Shuwen; Chen, Changshui; Mao, Hua; Jin, Shaoqin
2013-06-01
The feasibility of early detection of gastric cancer using near-infrared (NIR) Raman spectroscopy (RS) by distinguishing premalignant lesions (adenomatous polyp, n=27) and cancer tissues (adenocarcinoma, n=33) from normal gastric tissues (n=45) is evaluated. Significant differences in Raman spectra are observed among the normal, adenomatous polyp, and adenocarcinoma gastric tissues at 936, 1003, 1032, 1174, 1208, 1323, 1335, 1450, and 1655 cm-1. Diverse statistical methods are employed to develop effective diagnostic algorithms for classifying the Raman spectra of different types of ex vivo gastric tissues, including principal component analysis (PCA), linear discriminant analysis (LDA), and naive Bayesian classifier (NBC) techniques. Compared with PCA-LDA algorithms, PCA-NBC techniques together with leave-one-out, cross-validation method provide better discriminative results of normal, adenomatous polyp, and adenocarcinoma gastric tissues, resulting in superior sensitivities of 96.3%, 96.9%, and 96.9%, and specificities of 93%, 100%, and 95.2%, respectively. Therefore, NIR RS associated with multivariate statistical algorithms has the potential for early diagnosis of gastric premalignant lesions and cancer tissues in molecular level.
Assessment of spatial information for hyperspectral imaging of lesion
NASA Astrophysics Data System (ADS)
Yang, Xue; Li, Gang; Lin, Ling
2016-10-01
Multiple diseases such as breast tumor poses a great threat to women's health and life, while the traditional detection method is complex, costly and unsuitable for frequently self-examination, therefore, an inexpensive, convenient and efficient method for tumor self-inspection is needed urgently, and lesion localization is an important step. This paper proposes an self-examination method for positioning of a lesion. The method adopts transillumination to acquire the hyperspectral images and to assess the spatial information of lesion. Firstly, multi-wavelength sources are modulated with frequency division, which is advantageous to separate images of different wavelength, meanwhile, the source serves as fill light to each other to improve the sensitivity in the low-lightlevel imaging. Secondly, the signal-to-noise ratio of transmitted images after demodulation are improved by frame accumulation technology. Next, gray distributions of transmitted images are analyzed. The gray-level differences is constituted by the actual transmitted images and fitting transmitted images of tissue without lesion, which is to rule out individual differences. Due to scattering effect, there will be transition zones between tissue and lesion, and the zone changes with wavelength change, which will help to identify the structure details of lesion. Finally, image segmentation is adopted to extract the lesion and the transition zones, and the spatial features of lesion are confirmed according to the transition zones and the differences of transmitted light intensity distributions. Experiment using flat-shaped tissue as an example shows that the proposed method can extract the space information of lesion.
Tibial periosteal ganglion cyst: The ganglion in disguise.
Reghunath, Anjuna; Mittal, Mahesh K; Khanna, Geetika; Anil, V
2017-01-01
Soft tissue ganglions are commonly encountered cystic lesions around the wrist presumed to arise from myxomatous degeneration of periarticular connective tissue. Lesions with similar pathology in subchondral location close to joints, and often simulating a geode, is the less common entity called intraosseous ganglion. Rarer still is a lesion produced by mucoid degeneration and cyst formation of the periostium of long bones, rightly called the periosteal ganglion. They are mostly found in the lower extremities at the region of pes anserinus, typically limited to the periosteum and outer cortex without any intramedullary component. We report the case of a 62 year-old male who presented with a tender swelling on the mid shaft of the left tibia, which radiologically suggested a juxtacortical lesion extending to the soft tissue or a soft tissue neoplasm eroding the bony cortex of tibia. It was later diagnosed definitively as a periosteal ganglion in an atypical location, on further radiologic work-up and histopathological correlation.
Tibial periosteal ganglion cyst: The ganglion in disguise
Reghunath, Anjuna; Mittal, Mahesh K; Khanna, Geetika; Anil, V
2017-01-01
Soft tissue ganglions are commonly encountered cystic lesions around the wrist presumed to arise from myxomatous degeneration of periarticular connective tissue. Lesions with similar pathology in subchondral location close to joints, and often simulating a geode, is the less common entity called intraosseous ganglion. Rarer still is a lesion produced by mucoid degeneration and cyst formation of the periostium of long bones, rightly called the periosteal ganglion. They are mostly found in the lower extremities at the region of pes anserinus, typically limited to the periosteum and outer cortex without any intramedullary component. We report the case of a 62 year-old male who presented with a tender swelling on the mid shaft of the left tibia, which radiologically suggested a juxtacortical lesion extending to the soft tissue or a soft tissue neoplasm eroding the bony cortex of tibia. It was later diagnosed definitively as a periosteal ganglion in an atypical location, on further radiologic work-up and histopathological correlation. PMID:28515597
NASA Astrophysics Data System (ADS)
Zahedi, Sulmaz
This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.
Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging.
McCarthy, C L; Wilson, D J; Coltman, T P
2008-03-01
The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in differentiating soft tissue from osseous impingement. Synovitic lesions in two control patients suggest that abnormal antero-lateral soft tissue does not necessarily imply the presence of symptomatic ALI. Synovitic lesions in excess of 10 mm were associated with symptoms. Ultrasound will not demonstrate osteocartilaginous lesions or stress fractures and may overlook some loose bodies. Ultrasound findings together with clinical correlation can be used to direct arthroscopic examination and surgical debridement.
Afonso, P. Diana; Vinson, Emily N.; Turnbull, James D.; Morris, Karla K.; Foye, Adam; Madden, John F.; Roy Choudhury, Kingshuk; Febbo, Phillip G.; George, Daniel J.
2013-01-01
Purpose To determine the rate at which computed tomographically guided pelvic percutaneous bone biopsy in men with metastatic castration-resistant prostate cancer (mCRPC) yields adequate tissue for genomic profiling and to identify issues likely to affect diagnostic yields. Materials and Methods This study was institutional review board approved, and written informed consent was obtained. In a phase II trial assessing response to everolimus, 31 men with mCRPC underwent 54 biopsy procedures (eight men before and 23 men both before and during treatment). Variables assessed were lesion location (iliac wing adjacent to sacroiliac joint, iliac wing anterior and/or superior to sacroiliac joint, sacrum, and remainder of pelvis), mean lesion attenuation, subjective lesion attenuation (purely sclerotic vs mixed), central versus peripheral lesion sampling, lesion size, core number, and use of zoledronic acid for more than 1 year. Results Of 54 biopsy procedures, 21 (39%) yielded adequate tissue for RNA isolation and genomic profiling. Three of four sacral biopsies were adequate. Biopsies of the ilium adjacent to the sacroiliac joints were more likely adequate than those from elsewhere in the ilium (48% vs 28%, respectively). All five biopsies performed in other pelvic locations yielded inadequate tissue for RNA isolation. Mean attenuation of lesions with inadequate tissue was 172 HU greater than those with adequate tissue (621.1 HU ± 166 vs 449 HU ± 221, respectively; P = .002). Use of zoledronic acid, peripheral sampling, core number, and lesion size affected yields, but the differences were not statistically significant. Histologic examination with hematoxylin-eosin staining showed that results of 36 (67%) biopsies were positive for cancer; only mean attenuation differences were significant (707 HU ± 144 vs 473 HU ± 191, negative vs positive, respectively; P < .001). Conclusion In men with mCRPC, percutaneous sampling of osseous metastases for genomic profiling is possible, but use of zoledronic acid for more than 1 year may reduce the yield of adequate tissue for RNA isolation. Sampling large low-attenuating lesions at their periphery maximizes yield. © RSNA, 2013 PMID:23925271
Flame Retardant Effect of Nano Fillers on Polydimethylsiloxane Composites.
Jagdale, Pravin; Salimpour, Samera; Islam, Md Hujjatul; Cuttica, Fabio; Hernandez, Francisco C Robles; Tagliaferro, Alberto; Frache, Alberto
2018-02-01
Polydimethylsiloxane has exceptional fire retardancy characteristics, which make it a popular polymer in flame retardancy applications. Flame retardancy of polydimethylsiloxane with different nano fillers was studied. Polydimethylsiloxane composite fire property varies because of the shape, size, density, and chemical nature of nano fillers. In house made carbon and bismuth oxide nano fillers were used in polydimethylsiloxane composite. Carbon from biochar (carbonised bamboo) and a carbon by-product (carbon soot) were selected. For comparative study of nano fillers, standard commercial multiwall carbon nano tubes (functionalised, graphitised and pristine) as nano fillers were selected. Nano fillers in polydimethylsiloxane positively affects their fire retardant properties such as total smoke release, peak heat release rate, and time to ignition. Charring and surface ceramization are the main reasons for such improvement. Nano fillers in polydimethylsiloxane may affect the thermal mobility of polymer chains, which can directly affect the time to ignition. The study concludes that the addition of pristine multiwall carbon nano tubes and bismuth oxide nano particles as filler in polydimethylsiloxane composite improves the fire retardant property.
Laser probes for noninvasive coagulation of subsurface tissues
NASA Astrophysics Data System (ADS)
Chung, Chia-Chun; Permpongkosol, Sompol; Varkarakis, Ioannis M.; Lima, Guilherme; Franco, Nicholas; Hayman, Michael H.; Nicol, Theresa; Fried, Nathaniel M.
2006-02-01
Previous ex vivo tissue studies utilizing deep laser heating combined with contact cooling of the tissue surface produced noninvasive thermal destruction of subsurface tissue structures in skin and liver samples. This study describes the design and preliminary in vivo testing of two integrated laser/cooling probes for simultaneous Nd:YAG laser irradiation and sapphire contact cooling of liver and skin tissues in an in vivo, acute porcine model for potential use in laparoscopic and endoscopic surgery. Nd:YAG laser radiation with a wavelength of 1.06 μm, power of 20 W, 7.5-mm-diameter spot, 500-ms pulse length, and repetition rate of 0.625 Hz, was delivered to the tissue with a total irradiation time of 16 s. The tissue surface was continuously cooled with a sapphire plate maintained at -5 °C, and with pre- and post-ablation cooling times measuring 120 s and 30 s, resulting in a total operation time of 166 s per a lesion. Thermal lesions were created in liver and skin at a 1-mm depth below the tissue surface and with a 3-4 mm diameter. The laser parameters and lesion dimensions were comparable to previous ex vivo tissue studies. Preliminary in vivo animal studies demonstrate noninvasive creation of subsurface thermal lesions in tissue using Nd:YAG laser irradiation in conjunction with sapphire contact cooling. Chronic wound healing studies will be necessary to optimize the laser and cooling parameters. Potential clinical applications include endoscopic laser treatment of female stress urinary incontinence and thermal coagulation of early stage bladder tumors.
A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.
Maxwell, Adam D; Wang, Tzu-Yin; Yuan, Lingqian; Duryea, Alexander P; Xu, Zhen; Cain, Charles A
2010-12-01
Many ultrasound studies involve the use of tissue-mimicking materials to research phenomena in vitro and predict in vivo bioeffects. We have developed a tissue phantom to study cavitation-induced damage to tissue. The phantom consists of red blood cells suspended in an agarose hydrogel. The acoustic and mechanical properties of the gel phantom were found to be similar to soft tissue properties. The phantom's response to cavitation was evaluated using histotripsy. Histotripsy causes breakdown of tissue structures by the generation of controlled cavitation using short, focused, high-intensity ultrasound pulses. Histotripsy lesions were generated in the phantom and kidney tissue using a spherically focused 1-MHz transducer generating 15 cycle pulses, at a pulse repetition frequency of 100 Hz with a peak negative pressure of 14 MPa. Damage appeared clearly as increased optical transparency of the phantom due to rupture of individual red blood cells. The morphology of lesions generated in the phantom was very similar to that generated in kidney tissue at both macroscopic and cellular levels. Additionally, lesions in the phantom could be visualized as hypoechoic regions on a B-mode ultrasound image, similar to histotripsy lesions in tissue. High-speed imaging of the optically transparent phantom was used to show that damage coincides with the presence of cavitation. These results indicate that the phantom can accurately mimic the response of soft tissue to cavitation and provide a useful tool for studying damage induced by acoustic cavitation. Copyright © 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Tissue specific MR contrast media role in the differential diagnosis of cirrhotic liver nodules.
Lupescu, Ioana Gabriela; Capsa, Razvan A; Gheorghe, Liana; Herlea, Vlad; Georgescu, Serban A
2008-09-01
State-of-the-art magnetic resonance (MR) imaging using tissue specific contrast media facilitates detection and characterization in most cases of hepatic nodules. According to the currently used nomenclature, in liver cirrhosis there are only two major types of hepatocellular nodular lesions: regenerative lesions and dysplastic or neoplastic lesions. The purpose of this clinical imaging review is to provide information on the properties of tissue-specific MR contrast agents and on their usefulness in the demonstration of the pathologic changes that take place at the level of the hepatobiliary and reticuloendothelial systems during the carcinogenesis in liver cirrhosis.
Determination of lesion size by ultrasound during radiofrequency catheter ablation.
Awad, S; Eick, O
2003-01-01
The catheter tip temperature that is used to control the radiofrequency generator output poorly correlates to lesion size. We, therefore, evaluated lesions created in vitro using a B-mode ultrasound imaging device as a potential means to assess lesion generation during RF applications non-invasively. Porcine ventricular tissue was immersed in saline solution at 37 degrees C. The catheter was fixed in a holder and positioned in a parallel orientation to the tissue with an array transducer (7.5 MHz) app. 3 cm above the tissue. Lesions were produced either in a temperature controlled mode with a 4-mm tip catheter with different target temperatures (50, 60, 70 and 80 degrees C, 80 W maximum output) or in a power controlled mode (25, 50 and 75 W, 20 ml/min irrigation flow) using an irrigated tip catheter. Different contact forces (0.5 N, 1.0 N) were tested, and RF was delivered for 60 s. A total of 138 lesions was produced. Out of these, 128 could be identified on the ultrasound image. The lesion depth and volume was on average 4.1 +/- 1.6 mm and 52 +/- 53 mm3 as determined by ultrasound and 3.9 +/- 1.7 mm and 52 +/- 55 mm3 as measured thereafter, respectively. A linear correlation between the lesion size determined by ultrasound and that measured thereafter was demonstrated with a correlation coefficient of r = 0.87 for lesion depth and r = 0.93 for lesion volume. We conclude that lesions can be assessed by B-mode ultrasound imaging.
21 CFR 882.5500 - Lesion temperature monitor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... temperature at the site where a lesion (tissue destruction) is to be made when a surgeon uses a radiofrequency (RF) lesion generator and probe. (b) Classification. Class II (performance standards). ...
Quantitative morphology in canine cutaneous soft tissue sarcomas.
Simeonov, R; Ananiev, J; Gulubova, M
2015-12-01
Stained cytological specimens from 24 dogs with spontaneous soft tissue sarcomas [fibrosarcoma (n = 8), liposarcoma (n = 8) and haemangiopericytoma (n = 8)], and 24 dogs with reactive connective tissue lesions [granulation tissue (n = 12) and dermal fibrosis (n = 12)] were analysed by computer-assisted nuclear morphometry. The studied morphometric parameters were: mean nuclear area (MNA; µm(2)), mean nuclear perimeter (MNP; µm), mean nuclear diameter (MND mean; µm), minimum nuclear diameter (Dmin; µm) and maximum nuclear diameter (Dmax; µm). The study aimed to evaluate (1) possibility for quantitative differentiation of soft tissue sarcomas from reactive connective tissue lesions and (2) by using cytomorphometry, to differentiate the various histopathological soft tissue sarcomas subtypes in dogs. The mean values of all nuclear cytomorphometric parameters (except for Dmax) were statistically significantly higher in reactive connective tissue processes than in soft tissue sarcomas. At the same time, however, there were no considerable differences among the different sarcoma subtypes. The results demonstrated that the quantitative differentiation of reactive connective tissue processes from soft tissue sarcomas in dogs is possible, but the same was not true for the different canine soft tissue sarcoma subtypes. Further investigations on this topic are necessary for thorough explication of the role of quantitative morphology in the diagnostics of mesenchymal neoplasms and tumour-like fibrous lesions in dogs. © 2014 John Wiley & Sons Ltd.
Diviti, Sreelatha; Gupta, Nishant; Hooda, Kusum; Sharma, Komal; Lo, Lawrence
2017-04-01
Morel-Lavallee lesion is a post-traumatic soft tissue degloving injury. This is commonly associated with sports injury caused by a shearing force resulting in separation of the hypodermis from the deeper fascia. Most common at the greater trochanter, these injuries also occur at flank, buttock, lumbar spine, scapula and the knee. Separation of the tissue planes result in a complex serosanguinous fluid collection with areas of fat within it. The imaging appearance is variable and non specific, potentially mimicking simple soft tissue haematoma, superficial bursitis or necrotic soft tissue neoplasms. If not treated in the acute or early sub acute settings, these collections are at risk for superinfection, overlying tissue necrosis and continued expansion. In this review article, we discuss the clinical presentation, pathophysiology, imaging features and differential diagnostic considerations of Morel-Lavallee lesions. Role of imaging in guiding prompt and appropriate treatment has also been discussed.
White matter lesion extension to automatic brain tissue segmentation on MRI.
de Boer, Renske; Vrooman, Henri A; van der Lijn, Fedde; Vernooij, Meike W; Ikram, M Arfan; van der Lugt, Aad; Breteler, Monique M B; Niessen, Wiro J
2009-05-01
A fully automated brain tissue segmentation method is optimized and extended with white matter lesion segmentation. Cerebrospinal fluid (CSF), gray matter (GM) and white matter (WM) are segmented by an atlas-based k-nearest neighbor classifier on multi-modal magnetic resonance imaging data. This classifier is trained by registering brain atlases to the subject. The resulting GM segmentation is used to automatically find a white matter lesion (WML) threshold in a fluid-attenuated inversion recovery scan. False positive lesions are removed by ensuring that the lesions are within the white matter. The method was visually validated on a set of 209 subjects. No segmentation errors were found in 98% of the brain tissue segmentations and 97% of the WML segmentations. A quantitative evaluation using manual segmentations was performed on a subset of 6 subjects for CSF, GM and WM segmentation and an additional 14 for the WML segmentations. The results indicated that the automatic segmentation accuracy is close to the interobserver variability of manual segmentations.
A case series associated with different kinds of endo-perio lesions
Serper, Ahmet
2014-01-01
Pulpal and periodontal problems are responsible for more than half of the tooth mortality. There are some articles published in the literature about this issue. Many of them are quite old. There has been also lack of knowledge about the effect of endodontic treatment on the periodontal tissue healing and suitable treatment interval between endodontic and periodontal treatments. In this case report, different kinds of endo-perio lesion were treated with sequential endodontic and periodontal treatment. The follow-up radiographs showed complete healing of the hard and soft tissue lesions. The tooth with endo-perio lesions should be evaluated thoroughly in terms of any cracks and fracture, especially furcation areas for a long term prognosis. In this case report, it was showed that 3 months treatment intervals between endodontic treatment and periodontal surgery has no harmful effect on periodontal tissue healing. Key words:Endo-perio lesion, furcation, mandibular molar, bone graft, crack line, treatment interval. PMID:24596642
46 CFR 56.75-5 - Filler metal.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Filler metal. 56.75-5 Section 56.75-5 Shipping COAST... Brazing § 56.75-5 Filler metal. (a) The filler metal used in brazing must be a nonferrous metal or alloy having a melting point above 1,000 °F. and below that of the metal being joined. The filler metal must...
46 CFR 56.75-5 - Filler metal.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Filler metal. 56.75-5 Section 56.75-5 Shipping COAST... Brazing § 56.75-5 Filler metal. (a) The filler metal used in brazing must be a nonferrous metal or alloy having a melting point above 1,000 °F. and below that of the metal being joined. The filler metal must...
The Microstructural Evolution of Vacuum Brazed 1Cr18Ni9Ti Using Various Filler Metals
Chen, Yunxia; Cui, Haichao; Lu, Binfeng; Lu, Fenggui
2017-01-01
The microstructures and weldability of a brazed joint of 1Cr18Ni9Ti austenitic stainless steel with BNi-2, BNi82CrSiBFe and BMn50NiCuCrCo filler metals in vacuum were investigated. It can be observed that an interdiffusion region existed between the filler metal and the base metal for the brazed joint of Ni-based filler metals. The width of the interdiffusion region was about 10 μm, and the microstructure of the brazed joint of BNi-2 filler metal was dense and free of obvious defects. In the case of the brazed joint of BMn50NiCuCrCo filler metal, there were pits, pores and crack defects in the brazing joint due to insufficient wettability of the filler metal. Crack defects can also be observed in the brazed joint of BNi82CrSiBFe filler metal. Compared with BMn50NiCuCrCo and BNi82CrSiBFe filler metals, BNi-2 filler metal is the best material for 1Cr18Ni9Ti austenitic stainless steel vacuum brazing because of its distinct weldability. PMID:28772745
High-frequency sonography of temporary and permanent dermal fillers.
Grippaudo, Francesca Romana; Mattei, Mauro
2010-08-01
Dermal fillers are used widely; some have a permanent effect, whereas others are temporary. The aim of this study is to describe the ultrasonographic features of permanent and temporary fillers injected into patients for cosmetic purposes. Between December 2006 and April 2009, 36 subjects, aged 25-45, who had received lips or nasolabial fold filler augmentation, were enrolled for a high-frequency sonographic examination by a blinded investigator. The criteria for exclusion were a history of autoimmunity, infection, neoplastic diseases or episodes of local reactions to the injected filler. Twenty patients underwent a sonographic exam after the injection of a temporary filler (collagen or hyaluronic acid) by FRG; the rest were enrolled among patients seeking a consultation for further cosmetic reasons, but had been treated with an identifiable filler before. It was always possible to identify the filler at the site of injection. Seldom was it possible to discover a silent inflammatory reaction, otherwise unsuspected. The sonographic images differed according to the temporary or the permanent nature of the filler. Ultrasonography has proved to be a useful, non-invasive tool for the identification of the presence and type of the filler injected.
B218 Weld Filler Wire Characterization for Al-Li Alloy 2195
NASA Technical Reports Server (NTRS)
Bjorkman, Gerry; Russell, Carolyn
2000-01-01
NASA Marshall Space Flight Center, Lockheed Martin Space Systems- Michoud Operations, and McCook Metals have developed an aluminum-copper weld filler wire for fusion welding aluminum lithium alloy 2195. The aluminum-copper based weld filler wire has been identified as B218, a McCook Metals designation. B218 is the result of six years of weld filler wire development funded by NASA, Lockheed Martin, and McCook Metals. The filler wire chemistry was developed to produce enhanced 2195 weld and repair weld mechanical properties over the 4043 aluminum-silicon weld filler wire, which is currently used to weld 2195 on the Super Lightweight External Tank for the NASA Space Shuttle Program. An initial characterization was performed consisting of a repair weld evaluation using B218 and 4043 weld filler wires. The testing involved room temperature and cryogenic repair weld tensile testing along with fracture toughness testing. From the testing, B218 weld filler wire produce enhanced repair weld tensile strength, ductility, and fracture properties over 4043. B218 weld filler wire has proved to be a superior weld filler wire for welding aluminum lithium alloy 2195 over 4043.
Validating Ultrasound-based HIFU Lesion-size Monitoring Technique with MR Thermometry and Histology
NASA Astrophysics Data System (ADS)
Zhou, Shiwei; Petruzzello, John; Anand, Ajay; Sethuraman, Shriram; Azevedo, Jose
2010-03-01
In order to control and monitor HIFU lesions accurately and cost-effectively in real-time, we have developed an ultrasound-based therapy monitoring technique using acoustic radiation force to track the change in tissue mechanical properties. We validate our method with concurrent MR thermometry and histology. Comparison studies have been completed on in-vitro bovine liver samples. A single-element 1.1 MHz focused transducer was used to deliver HIFU and produce acoustic radiation force (ARF). A 5 MHz single-element transducer was placed co-axially with the HIFU transducer to acquire the RF data, and track the tissue displacement induced by ARF. During therapy, the monitoring procedure was interleaved with HIFU. MR thermometry (Philips Panorama 1T system) and ultrasound monitoring were performed simultaneously. The tissue temperature and thermal dose (CEM43 = 240 mins) were computed from the MR thermometry data. The tissue displacement induced by the acoustic radiation force was calculated from the ultrasound RF data in real-time using a cross-correlation based method. A normalized displacement difference (NDD) parameter was developed and calibrated to estimate the lesion size. The lesion size estimated by the NDD was compared with both MR thermometry prediction and the histology analysis. For lesions smaller than 8mm, the NDD-based lesion monitoring technique showed very similar performance as MR thermometry. The standard deviation of lesion size error is 0.66 mm, which is comparable to MR thermal dose contour prediction (0.42 mm). A phased array is needed for tracking displacement in 2D and monitoring lesion larger than 8 mm. The study demonstrates the potential of our ultrasound based technique to achieve precise HIFU lesion control through real-time monitoring. The results compare well with histology and an established technique like MR Thermometry. This approach provides feedback control in real-time to terminate therapy when a pre-determined lesion size is achieved, and can be extended to 2D and implemented on commercial ultrasound scanner systems.
Hancock, Joseph G.
1968-01-01
Initial symptoms and increases in respiration, apparent free space, and rate of leakage of amino acids occurred concomitantly in squash (Cucurbita maxima Dcne) hypocotyls infected by Hypomyces solani f. sp. cucurbitae Snyd. and Hans. Young, rapidly expanding lesions had greater respiratory rates and apparent free space than comparable tissues from healthy plants. Hypocotyl tissues above (1-45 mm) lesions possessed greater endogenous respiratory rates (2-3 times) and lower respiratory quotients than similar tissues from healthy plants. But no differences were found in membrane permeability to nonelectrolytes and water and in apparent free space between cells above lesions and healthy hypocotyls. Host cells contiguous to fungal hyphae at lesion margins were completely permeable to solutes and failed to accumulate neutral red or exhibit cyclosis. Images PMID:16656953
The Study of the Interaction between Silica Filler and Silicone Rubber
NASA Astrophysics Data System (ADS)
Liu, Jiesheng; Gong, Xiaoqiang; Zhang, Rongtang
2018-01-01
The interaction between silica filler and silicone rubber was studied by swelling ratio, Kraus curve and crosslinking density test. The results showed that lower values of Vro/Vrf and swelling ratio in modified filler system suggests good filler-matrix interactions. The composites with silane coupling agents show higher crosslink-density compared that of untreated ones. In the light of the above statement, it can be concluded that modification of filler is the crucial factor in creating a good interaction between the filler and silicone rubber.
Tissue lesion created by HIFU in continuous scanning mode
NASA Astrophysics Data System (ADS)
Fan, Tingbo; Liu, Zhenbo; Zhang, Dong
2012-09-01
The lesion formation was numerically and experimentally investigated by the continuous scanning mode. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetov (KZK) equation and bio-heat equation. Measurements were performed on porcine liver tissues using a 1.01 MHz single-element focused transducer at various acoustic powers, confirmed the predicted results. Controlling of the peak temperature and lesion by the scanning speed may be exploited for improvement of efficiency in HIFU therapy.
de Arriba, Alvaro; Lassaletta, Luis; Pérez-Mora, Rosa María; Gavilán, Javier
2013-01-01
Differential diagnosis of geniculate ganglion tumours includes chiefly schwannomas, haemangiomas and meningiomas. We report the case of a patient whose clinical and imaging findings mimicked the presentation of a facial nerve schwannoma.Pathological studies revealed a lesion with nerve bundles unstructured by intense collagenisation. Consequently, it was called fibrous connective tissue lesion of the facial nerve. Copyright © 2011 Elsevier España, S.L. All rights reserved.
Abrasive Wear of Four Direct Restorative Materials by Standard and Whitening Dentifrices
2013-06-01
after an acidic challenge . Enamel loss was significantly greater when erosive and abrasive effects were combined. They concluded that acid-softened...surrounding soft tissues. Another benefit of restoration is the elimination of a challenging area for the patient and hygienist to clean. These areas...abrasion challenge ; the resin cement with the smallest sized filler particles had the smallest weight loss and maintained the smoothest surface of all the
Greaves, Erin; Cousins, Fiona L.; Murray, Alison; Esnal-Zufiaurre, Arantza; Fassbender, Amelie; Horne, Andrew W.; Saunders, Philippa T.K.
2015-01-01
Endometriosis is an estrogen-dependent inflammatory disorder characterized by the presence of endometrial tissue outside the uterine cavity. Patients experience chronic pelvic pain and infertility, with the most likely origin of the tissue deposits (lesions) being endometrial fragments shed at menses. Menstruation is an inflammatory process associated with a dramatic increase in inflammatory mediators and tissue-resident immune cells. In the present study, we developed and validated a mouse model of endometriosis using syngeneic menstrual endometrial tissue introduced into the peritoneum of immunocompetent mice. We demonstrate the establishment of endometriotic lesions that exhibit similarities to those recovered from patients undergoing laparoscopy. Specifically, in both cases, lesions had epithelial (cytokeratin+) and stromal (vimentin/CD10+) cell compartments with a well-developed vasculature (CD31+ endothelial cells). Expression of estrogen receptor β was increased in lesions compared with the peritoneum or eutopic endometrium. By performing experiments using mice with green fluorescent protein–labeled macrophages (MacGreen) in reciprocal transfers with wild-type mice, we obtained evidence that macrophages present in the peritoneum and in menses endometrium can contribute to the inflammatory microenvironment of the lesions. In summary, we developed a mouse model of endometriosis that exhibits similarities to human peritoneal lesions with respect to estrogen receptor expression, inflammation, and macrophage infiltration, providing an opportunity for further studies and the possible identification of novel therapies for this perplexing disorder. PMID:24910298
Proton MRS of the peritumoral brain.
Chernov, Mikhail F; Kubo, Osami; Hayashi, Motohiro; Izawa, Masahiro; Maruyama, Takashi; Usukura, Masao; Ono, Yuko; Hori, Tomokatsu; Takakura, Kintomo
2005-02-15
Long-echo (TR: 2000 ms, TE: 136 ms) proton MRS of the cerebral tissue in the vicinity to intracranial lesion was done in 15 patients, mainly with parenchymal brain tumors. Significant decrease of N-acetylaspartate (NAA) (P<0.001) and more frequent presence of lactate (P<0.01) comparing with distant normal white matter were found in the perilesional brain tissue. The level of NAA in the perilesional brain tissue had negative associations with presence of lactate in the lesion (P<0.05), excess of lactate in the lesion compared to perilesional brain (P<0.01), grade of the perilesional edema (P<0.01) and patient's age (P<0.05). Multivariate analysis disclosed that identification of lactate in the lesion is associated with lower relative NAA content in the perilesional brain tissue, independently on the presence or absence of any other factor, including brain edema (P<0.001). In patients with lobar lesions who had at least one epileptic seizure during course of their disease the relative NAA content in the perilesional brain was significantly lower, comparing with those who were seizure-free (P<0.05). Therefore, lactate diffused from the tumor, or other metabolites secreted by lactate-producing neoplasm, should be considered as important contributors to the neuronal dysfunction in the surrounding brain. Decrease of NAA in the vicinity to intracranial lesions may reflect neuronal alteration responsible for associated epilepsy.
Lima, Cassio A; Goulart, Viviane P; Correa, Luciana; Zezell, Denise M
2016-07-01
Vibrational spectroscopic methods associated with multivariate statistical techniques have been succeeded in discriminating skin lesions from normal tissues. However, there is no study exploring the potential of these techniques to assess the alterations promoted by photodynamic effect in tissue. The present study aims to demonstrate the ability of Fourier Transform Infrared (FTIR) spectroscopy on Attenuated total reflection (ATR) sampling mode associated with principal component-linear discriminant analysis (PC-LDA) to evaluate the biochemical changes caused by photodynamic therapy (PDT) in skin neoplastic tissue. Cutaneous neoplastic lesions, precursors of squamous cell carcinoma (SCC), were chemically induced in Swiss mice and submitted to a single session of 5-aminolevulinic acid (ALA)-mediated PDT. Tissue sections with 5 μm thickness were obtained from formalin-fixed paraffin-embedded (FFPE) and processed prior to the histopathological analysis and spectroscopic measurements. Spectra were collected in mid-infrared region using a FTIR spectrometer on ATR sampling mode. Principal Component-Linear Discriminant Analysis (PC-LDA) was applied on preprocessed second derivatives spectra. Biochemical changes were assessed using PCA-loadings and accuracy of classification was obtained from PC-LDA . Sub-bands of Amide I (1,624 and 1,650 cm(-1) ) and Amide II (1,517 cm(-1) ) indicated a protein overexpression in non-treated and post-PDT neoplastic tissue compared with healthy skin, as well as a decrease in collagen fibers (1,204, 1,236, 1,282, and 1,338 cm(-1) ) and glycogen (1,028, 1,082, and 1,151 cm(-1) ) content. Photosensitized neoplastic tissue revealed shifted peak position and decreased β-sheet secondary structure of proteins (1,624 cm(-1) ) amount in comparison to non-treated neoplastic lesions. PC-LDA score plots discriminated non-treated neoplastic skin spectra from post-PDT cutaneous lesions with accuracy of 92.8%, whereas non-treated neoplastic skin was discriminated from healthy tissue with 93.5% accuracy and post-PDT cutaneous lesions was discriminated from healthy tissue with 89.7% accuracy. PC-LDA was able to discriminate ATR-FTIR spectra of non-treated and post-PDT neoplastic lesions, as well as from healthy skin. Thus, the method can be used for early diagnosis of premalignant skin lesions, as well as to evaluate the response to photodynamic treatment. Lasers Surg. Med. 48:538-545, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
USDA-ARS?s Scientific Manuscript database
The protozoan parasite Toxoplasma gondii is one of the most widely distributed and most successful microorganism. Of all warm blooded hosts, only cats can excrete the environmentally resistant stage, the oocyst. T. gondii manipulates rodent behavior so that infected rodents are losing fear of the ca...
Blindness following cosmetic injections of the face.
Lazzeri, Davide; Agostini, Tommaso; Figus, Michele; Nardi, Marco; Pantaloni, Marcello; Lazzeri, Stefano
2012-04-01
Complications following facial cosmetic injections have recently heightened awareness of the possibility of iatrogenic blindness. The authors conducted a systematic review of the available literature to provide the best evidence for the prevention and treatment of this serious eye injury. The authors included in the study only the cases in which blindness was a direct consequence of a cosmetic injection procedure of the face. Twenty-nine articles describing 32 patients were identified. In 15 patients, blindness occurred after injections of adipose tissue; in the other 17, it followed injections of various materials, including corticosteroids, paraffin, silicone oil, bovine collagen, polymethylmethacrylate, hyaluronic acid, and calcium hydroxyapatite. Some precautions may minimize the risk of embolization of filler into the ophthalmic artery following facial cosmetic injections. Intravascular placement of the needle or cannula should be demonstrated by aspiration before injection and should be further prevented by application of local vasoconstrictor. Needles, syringes, and cannulas of small size should be preferred to larger ones and be replaced with blunt flexible needles and microcannulas when possible. Low-pressure injections with the release of the least amount of substance possible should be considered safer than bolus injections. The total volume of filler injected during the entire treatment session should be limited, and injections into pretraumatized tissues should be avoided. Actually, no safe, feasible, and reliable treatment exists for iatrogenic retinal embolism. Nonetheless, therapy should theoretically be directed to lowering intraocular pressure to dislodge the embolus into more peripheral vessels of the retinal circulation, increasing retinal perfusion and oxygen delivery to hypoxic tissues. Risk, V.
Soy-based fillers for thermoset composites
NASA Astrophysics Data System (ADS)
Watt, Paula
Considerable work has been done with bio-based fillers in thermoplastics. Wood dust has been used for decades in wood plastic composites in conjunction with recycled high HDPE and PET. In recent years rapidly renewable fillers derived from dried distillery grains and from wood have been introduced commercially for thermoset polymers. These fillers provide bio-content and weight reduction to thermoset molding compounds but issues with moisture absorption and polymerization inhibition have limited their commercial acceptance. The intent of this research was to develop a bio-based filler suitable for thermoset composites. This filler would provide a low density alternative to mined mineral filler, such as CaCO3 or clay. Composites made with these fillers would be lighter in weight, which is desirable for many markets, particularly transportation. Cost parity to the mineral fillers, on a volume basis, was desirable and the use of green chemistry principles was a key objective of the project. This work provides a basis from which further development of modified soy flours as fillers for thermoset composites will continue. Biomass has been evaluated as fillers for thermoset composites since the early 1980s but failed to gain commercial acceptance due to excessive water absorption and inhibition issues with free radical curing. Biomass, with a large percentage of carbohydrates, are very hydrophilic due to their abundance of hydroxyl groups, while biomass, high in lignin, resulted in inhibition of the free radical cure of the unsaturated styrenated polyester matrix systems. Generally protein use as a filler is not desirable due to its food value. Torrefaction has proved to be a good, cost effective, process to reduce hydrophilicity of high cellulose feedstock. Surprising, however, some levels of torrefaction were found to induce the inhibition effect of the filler. Scientific inquiry into this problem proved that aromatics form during the torrefaction process and can become problematic when threshold levels are reached. Studies to determine suitable levels and appropriate processes provided options for manufacture of suitable fillers.
Pace, Lauren A; Plate, Johannes F; Smith, Thomas L; Van Dyke, Mark E
2013-08-01
Peripheral nerve injuries requiring surgery can be repaired by autograft, the clinical "gold standard", allograft, or nerve conduits. Most published clinical studies show the effectiveness of nerve conduits in small size defects in sensory nerves. Many preclinical studies suggest that peripheral nerve regeneration through conduits can be enhanced and repair lengths increased with the use of a biomaterial filler in the conduit lumen. We have previously shown that a luminal hydrogel filler derived from human hair keratin (HHK) can improve electrophysiological and histological outcomes in mouse, rabbit, and non-human primate nerve injury models, but insight into potential mechanisms has been lacking. Based on the premise that a keratin biomaterial (KOS) hydrogel provides an instantaneous structural matrix within the lumen, the current study compares the cellular behavior elicited by KOS hydrogel to Matrigel (MAT) and saline (SAL) conduit fillers in a 1 cm rat sciatic nerve injury model at early stages of regeneration. While there was little difference in initial cellular influx, the KOS group showed earlier migration of dedifferentiated Schwann cells (SC) from the proximal nerve end compared to the other groups. The KOS group also showed faster SC dedifferentiation and myelin debris clearance, and decreased macrophage infiltration during Wallerian degeneration of the distal nerve tissue. Copyright © 2013 Elsevier Ltd. All rights reserved.
Seward, Austin C; Meara, Daniel J
2013-07-01
Silicone and other fillers have become a popular aid to increase soft tissue density, decrease static skin rhytids, and treat muscle wasting, particularly in the face. As a result, injectable silicone has become popular in patients with the human immunodeficiency virus (HIV). It has been postulated that highly active antiretroviral therapy detrimentally induces the physiologic process of fat atrophy of the temporal and buccal fat pads of the face and regional fat wasting of the arms, legs, and buttocks and that HIV protease inhibitors may induce fat atrophy by binding and inhibiting homologous human proteins that are involved in fat metabolism. The classic hollowed-out facial appearance linked to HIV positivity can have detrimental social implications in infected patients who are otherwise very functional. In consequence, facial implantation, fat transplantation, and dermal and subcutaneous fillers have been used to aid in the restoration of facial appearance. This report describes the case of a patient who underwent multiple rounds of silicone injections and complained of intermittent facial swelling and pain long after the injections. The authors report on the safety of specific medical-grade injectable fillers and techniques found to be safely effective, especially in the HIV-positive population. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Carvalho, C R; Wrobel, S; Meyer, C; Brandenberger, C; Cengiz, I F; López-Cebral, R; Silva-Correia, J; Ronchi, G; Reis, R L; Grothe, C; Oliveira, J M; Haastert-Talini, K
2018-05-01
Peripheral nerve injuries (PNI) resulting in a gap to be bridged between the transected nerve ends are commonly reconstructed with autologous nerve tissue, but there is a need for valuable alternatives. This experimental work considers the innovative use of the biomaterial Gellan Gum (GG) as a luminal filler for nerve guidance channels made from chitosan with a 5% degree of acetylation. The engineered constructs should remodel the structural support given to regenerating axons by the so-called bands of Büngner. Four different GG formulations were produced by combining varying amounts of High-Acyl GG (HA-GG) and Methacrylated GG (MA-GG). The effective porosity of the freeze-dried networks was analysed by SEM and micro-CT 3D reconstructions, while the degradation and swelling abilities were characterized in vitro for up to 30 days. The metabolic activity and viability of immortalized Schwann cells seeded onto the freeze-dried networks were also evaluated. Finally, the developed hydrogel formulations were freeze-dried within the chitosan nerve guides and implanted in a 10 mm rat sciatic nerve defect. Functional and histomorphological analyses after 3, 6, and 12 weeks in vivo revealed that although it did not result in improved nerve regeneration, the NGC25:75 formulations could provide a basis for further development of GG scaffolds as luminal fillers for hollow nerve guidance channels.
Dennison, J B
1982-09-01
Microfilled resins generally have physical properties inferior to those of conventional composites. A lower in organic filler content or higher polymer/filled ratio results in a lower modulus of elasticity, greater thermal dimensional change, less resistance to indentation and abrasion, and greater water sorption. The ability to finish and to maintain a smooth surface texture is a major advantage, although it has not been proved clinically that microfilled resin restorations result in less plaque adherence nor do they enhance soft tissue response. Early clinical trials, after two to three years in vivo, indicate a greater wear resistance for these materials than for conventional composites. At this time, current evidence suggests that a decrease in filler particles size to less than 1 micrometer and a lower filler loading of the resin matrix permit the clinical development and maintenance of a smooth surface texture on restoration surfaces. There is no published evidence that the decrease in many of the physical properties leads to early signs of clinical deterioration and failure. In vivo studies extended for longer periods are necessary to make a knowledgeable judgment on the true clinical value of these composites. A classification system for composite restorative resins is being prepared by the Council on Dental Materials, Instruments, and Equipment. It will be published in a future issue of The Journal.
Joint Workplan on Filler Investigations for DPCs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, Ernest; Brady, Patrick Vane
2017-12-01
This workplan addresses filler attributes (i.e., possible requirements), assumptions needed for analysis, selection of filler materials, testing needs, and a long-range perspective on R&D activities leading to filler demonstration and a safety basis for implementation.
NASA Astrophysics Data System (ADS)
Arroyo, Junior; Saavedra, Ana Cecilia; Guerrero, Jorge; Montenegro, Pilar; Aguilar, Jorge; Pinto, Joseph A.; Lobo, Julio; Salcudean, Tim; Lavarello, Roberto; Castañeda, Benjamín.
2018-03-01
Breast cancer is a public health problem with 1.7 million new cases per year worldwide and with several limitations in the state-of-art screening techniques. Ultrasound elastography involves a set of techniques intended to facilitate the noninvasive diagnosis of cancer. Among these, Vibro-elastography is an ultrasound-based technique that employs external mechanical excitation to infer the elastic properties of soft tissue. In this paper, we evaluate the Vibro-elastography performance in the differentiation of benign and malignant breast lesions. For this study, a group of 18 women with clinically confirmed tumors or suspected malignant breast lesions were invited to participate. For each volunteer, an elastogram was obtained, and the mean elasticity of the lesion and the adjacent healthy tissue were calculated. After the acquisition, the volunteers underwent core-needle biopsy. The histopathological results allowed to validate the Vibro-elastography diagnosis, which ranged from benign to malignant lesions. Results indicate that the mean elasticity value of the benign lesions, malignant lesions and healthy breast tissue were 39.4 +/- 12 KPa, 55.4 +/- 7.02 KPa and 23.91 +/- 4.57 kPa, respectively. The classification between benign and malignant breast cancer was performed using Support Vector Machine based on the measured lesion stiffness. A ROC curve permitted to quantify the accuracy of the differentiation and to define a suitable cutoff value of stiffness, obtaining an AUC of 0.90 and a cutoff value of 44.75 KPa. The results obtained suggest that Vibro-elastography allows differentiating between benign and malignant lesions. Furthermore, the elasticity values obtained for benign, malignant and healthy tissue are consistent with previous reports.
NASA Astrophysics Data System (ADS)
Hänscheid, H.; Lassmann, M.; Buck, A. K.; Reiners, C.; Verburg, F. A.
2014-05-01
Radioiodine scintigraphy influences staging and treatment in patients with differentiated thyroid carcinoma. The limit of detection for fractional uptake in an iodine avid focus in a scintigraphic image was determined from the number of lesion net counts and the count density of the tissue background. The count statistics were used to calculate the diagnostic activity required to elevate the signal from a lesion with a given uptake significantly above a homogeneous background with randomly distributed counts per area. The dependences of the minimal uptake and the minimal size of lesions visible in a scan on several parameters of influence were determined by linking the typical biokinetics observed in iodine avid tissue to the lesion mass and to the absorbed dose received in a radioiodine therapy. The detection limits for fractional uptake in a neck lesion of a typical patient are about 0.001% after therapy with 7000 MBq, 0.01% for activities typically administered in diagnostic assessments (74-185 MBq), and 0.1% after the administration of 10 MBq I-131. Lesions at the limit of detection in a diagnostic scan with biokinetics eligible for radioiodine therapy are small with diameters of a few millimeters. Increasing the diagnostic activity by a factor of 4 reduces the diameter of visible lesions by 25% or about 1 mm. Several other determinants have a comparable or higher influence on the limit of detection than the administered activity; most important are the biokinetics in both blood pool and target tissue and the time of measurement. A generally valid recommendation for the timing of the scan is impossible as the time of the highest probability to detect iodine avid tissue depends on the administered activity as well as on the biokinetics in the lesion and background in the individual patient.
Lesion expansion of Sclerotinia minor and S. sclerotiorum on two peanut cultivars
USDA-ARS?s Scientific Manuscript database
Inoculation of peanut stems with Sclerotinia minor (SM) or S. sclerotiorum (SS) causes Sclerotinia blight, which is characterized by the formation of tan, water-soaked lesions on infected plant parts, leading to tissue collapse and necrosis of the affected tissue. Significant losses occur in Oklaho...
Lebelo, Ramokone L; Thys, Sofie; Benoy, Ina; Depuydt, Christophe E; Bogers, John-Paul; Bida, Meshack N; Mphahlele, M Jeffrey
2015-10-01
The aim of the study was to identify specific human papillomavirus (HPV) type responsible for malignancy in penile tissue samples using laser micro-dissection and TaqMan quantitative real-time PCR (qPCR). The study was based on two pre-malignant and seven malignant penile tissue samples and laser micro-dissection was performed on all. Genotyping was performed on whole tissue sections and laser micro-dissection samples using qPCR. Two whole tissue section samples were HPV negative while seven were HPV positive. In four samples that were single HPV infections with whole tissue section PCR, identical HPV types were confirmed with laser micro-dissection PCR. Clearly confirming that the single HPV type detected is responsible for malignancy. In two samples that had multiple HPV infections with whole tissue section PCR, only one HPV type with the highest viral load was detected with laser micro-dissection PCR, suggesting that the HPV type with the highest viral load is most likely the cause of that particular lesion. HPV 11 and/or HPV 16 were the only types detected with laser micro-dissection PCR in these cases, compared to multiple HPV types (HPV 11, HPV 16, HPV 18, HPV 31, HPV 33, HPV 35, and HPV 39) initially detected with whole tissue section PCR. HPV 11 was associated with verrucous lesions while HPV 16 was associated with squamous cell carcinoma and PIN 3 lesions. This study confirms that laser micro-dissection and qPCR are essential tools in identifying the HPV types responsible for malignancy in penile lesions, particularly in samples with multiple infections. © 2015 Wiley Periodicals, Inc.
21 CFR 882.5500 - Lesion temperature monitor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lesion temperature monitor. 882.5500 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5500 Lesion temperature monitor. (a) Identification. A lesion temperature monitor is a device used to monitor the tissue...
21 CFR 882.5500 - Lesion temperature monitor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lesion temperature monitor. 882.5500 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5500 Lesion temperature monitor. (a) Identification. A lesion temperature monitor is a device used to monitor the tissue...
21 CFR 882.5500 - Lesion temperature monitor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lesion temperature monitor. 882.5500 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5500 Lesion temperature monitor. (a) Identification. A lesion temperature monitor is a device used to monitor the tissue...
Concordance between clinical and histopathologic diagnoses of oral mucosal lesions.
Patel, Kush J; De Silva, Harsha L; Tong, Darryl C; Love, Robert M
2011-01-01
To study the epidemiology of oral soft tissue lesions in New Zealand from 2002 to 2006 and to determine the concordance between the clinical diagnosis and the definitive histopathologic diagnosis achieved by general dental practitioners and by specialists. The details from biopsy referrals and the corresponding histopathologic reports of oral soft tissue lesions were recorded into a statistical software package, and the concordance between the clinical diagnosis and histopathologic diagnosis was determined for all the lesions. Most biopsies were benign lesions, and both clinician groups achieved a high diagnostic concordance for these lesions. However, when considering all lesion types, the overall concordance for both groups was a moderate 50.6%, with little difference between specialists and general dental practitioners, although specialists were more accurate in diagnosing a malignant or premalignant lesion. The clinical and histopathologic concordance achieved by oral health practitioners in New Zealand appears to be moderate. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Safety and effectiveness of hyaluronic acid fillers in skin of color.
Grimes, Pearl E; Thomas, Jane A; Murphy, Diane K
2009-09-01
To assess the safety and effectiveness of hyaluronic acid (HA) fillers in skin of color. Two prospective studies followed up subjects with Fitzpatrick skin phototypes of IV, V, or VI for 24 weeks after dermal filler injections. In a double-blind, randomized study, subjects were injected with one of three high concentration (24 mg/mL) HA fillers (Juvéderm Ultra, Ultra Plus, and 30) in one nasolabial fold and Zyplast collagen in the other. In an open-label, randomized study, subjects received one of three low concentration (5.5 mg/mL) HA fillers (Hylaform, Hylaform Plus, and Captique) in both nasolabial folds. A total of 160 subjects (a subset of 439 study subjects) were randomized and treated with one of the three high concentration fillers, and 119 subjects were randomized and treated with one of the three low concentration fillers. For subjects treated with the high concentration fillers there were no occurrences of hypersensitivity or hypertrophic scarring, and no increased incidence of hyperpigmentation or hypopigmentation in non-Caucasian vs. Caucasian subjects. For subjects treated with the low concentration fillers there were no occurrences of keloid formation, hypertrophic scarring, hypopigmentation, hypersensitivity, and three instances of mild hyperpigmentation. For all of the fillers the majority of subjects maintained >/=1 point improvement in nasolabial fold severity scores through 24 weeks. All of the HA fillers were well tolerated in individuals with skin of color and demonstrated effectiveness throughout the 24 week period. Furthermore, the fillers provided smooth, natural-looking wrinkle correction in darker skin types.
Han, Seokmin; Kang, Dong-Goo
2014-01-01
An easily implementable tissue cancellation method for dual energy mammography is proposed to reduce anatomical noise and enhance lesion visibility. For dual energy calibration, the images of an imaging object are directly mapped onto the images of a customized calibration phantom. Each pixel pair of the low and high energy images of the imaging object was compared to pixel pairs of the low and high energy images of the calibration phantom. The correspondence was measured by absolute difference between the pixel values of imaged object and those of the calibration phantom. Then the closest pixel pair of the calibration phantom images is marked and selected. After the calibration using direct mapping, the regions with lesion yielded different thickness from the background tissues. Taking advantage of the different thickness, the visibility of cancerous lesions was enhanced with increased contrast-to-noise ratio, depending on the size of lesion and breast thickness. However, some tissues near the edge of imaged object still remained after tissue cancellation. These remaining residuals seem to occur due to the heel effect, scattering, nonparallel X-ray beam geometry and Poisson distribution of photons. To improve its performance further, scattering and the heel effect should be compensated.
Kriz, Petr; Kaevska, Marija; Slana, Iva; Bartejsova, Iva; Pavlik, Ivo
2014-01-01
This study was performed on 40 finished pigs from one herd naturally infected with Mycobacterium avium subsp. avium. The aim was to investigate the presence and amount of M. a. avium in samples of lymph nodes and diaphragm tissues collected during routine postmortem inspection using the triplex quantitative real time PCR (qPCR) method. We collected, in total, 107 samples: various lymph nodes affected by gross tuberculosis (TB)-like lesions from 17 pig carcasses, as well as samples of head and mesenteric lymph nodes from 23 carcasses without TB-like lesions. Samples of diaphragm tissues were collected from all carcasses. M. a. avium was detected in one or more tissue samples collected from half of the slaughtered pigs tested. Samples of diaphragm tissues of three pigs with detected TB-like lesions contained M. a. avium (10(2) to 10(3) cells per g of sample); the organism was not detected in diaphragm tissues from pigs without TB-like lesions. The qPCR method may be useful for quantification of M. a. avium in pigs for the purposes of foodborne risk assessment.
NASA Astrophysics Data System (ADS)
Winardi, Y.; Triyono; Wijayanta, A. T.
2017-02-01
In this study, the effect of filler and heat treatment on the physical and mechanical properties of the brazed joint carbide tip and steel was investigated. Tip carbide YG6 and low carbon steel (SS400) is joining by torch brazing with two filler metals, silver, and copper filler. Heat treatment was performed in induction furnace. Microstructure and shear strength of the brazed joint have been investigated. Many silver filler layer are formed on the surface of the base metal rather then using copper filler. The highest shear strength is achieved using a silver filler metal at temperatur 725°C. The highest shear load is 18.62 kN.
NASA Astrophysics Data System (ADS)
Shanmugharaj, A. M.; Bhowmick, Anil K.
2004-01-01
The rheological properties of styrene-butadiene rubber (SBR) loaded with dual phase filler were measured using Monsanto Processability Tester (MPT) at three different temperatures (100°C, 110°C and 130°C) and four different shear rates (61.3, 306.3, 613, and 1004.5 s -1). The effect of electron beam modification of dual phase filler in absence and presence of trimethylol propane triacrylate (TMPTA) or triethoxysilylpropyltetrasulphide (Si-69) on melt flow properties of SBR was also studied. The viscosity of all the systems decreases with shear rate indicating their pseudoplastic or shear thinning nature. The higher shear viscosity for the SBR loaded with the electron beam modified filler is explained in terms of variation in structure of the filler upon electron beam irradiation. Die swell of the modified filler loaded SBR is slightly higher than that of the unmodified filler loaded rubber, which is explained by calculating normal stress difference for the systems. Activation energy of the modified filler loaded SBR systems is also slightly higher than that of the control filler loaded SBR system.
Filler particle size and composite resin classification systems.
Lang, B R; Jaarda, M; Wang, R F
1992-11-01
The currently used composite resin classification systems need review if they are to continue to serve as descriptives and quantitative parameters denoting the filler particle content of these materials. Examination of the particles in 12 composite resins using a technique of washing the filler particles from the matrix of the composite resin was presented as yet another method of grouping composites according to filler particle content. Light microscopic examination of the filler particles that remained provided a separation of the 12 materials into four easily distinguished groups based on filler particle sizes. The wear of the 12 composite resins determined in a previous study was examined in relation to the classification of the materials by the currently available systems. The wear values were also examined using the groupings of the materials according to their filler particle sizes as determined by separating the particles from the matrix by the washing technique. Grouping composites on the basis of the filler particle sizes found after washing was easily correlated with wear and supported the suggestion that composites with smaller filler particles wear less.
Bone resorptive activity in symptomatic and asymptomatic apical lesions of endodontic origin.
Salinas-Muñoz, M; Garrido-Flores, M; Baeza, M; Huamán-Chipana, P; García-Sesnich, J; Bologna, R; Vernal, R; Hernández, M
2017-11-01
The aim of this study is to assess the levels and diagnostic accuracy of a set of bone resorption biomarkers, including TRAP-5, RANKL, and OPG in symptomatic and asymptomatic apical lesions and controls. Apical tissues from symptomatic and asymptomatic apical periodontitis patients and periodontal ligaments from healthy teeth extracted for orthodontic reasons were processed for tissue homogenization and the levels of TRAP-5, RANKL, and OPG were determined by multiplex assay. Marker levels were analyzed by Kruskal Wallis test, and diagnostic accuracy was analyzed with ROC curves. Higher levels of RANKL, OPG, and RANKL/OPG ratio were determined in both types of apical lesions compared to healthy periodontal ligament, whereas higher TRAP-5 levels were found only in symptomatic apical lesions (p < 0.05). OPG, RANKL, and RANKL/OPG ratio showed diagnostic potential to identify apical lesions versus healthy controls (AUC = 0.69, p < 0.05); while TRAP-5 showed a potential to discriminate symptomatic versus asymptomatic apical periodontitis (AUC = 0.71, p < 0.05) and healthy controls (AUC = 0.83, p < 0.05). Apical lesions showed higher RANKL and OPG levels than healthy tissues. TRAP-5 levels were the highest in symptomatic apical lesions, suggesting that these represent a progressive state, and showed diagnostic potential. Clinically symptomatic apical periodontitis might represent biologically progressive apical lesions based on TRAP5 levels. TRAP5 has diagnostic potential to identify these lesions, representing a candidate prognostic biomarker.
Czeczuga-Semeniuk, E; Wołczyński, S
2008-01-01
Vitamin A takes part in many physiological and pathological processes in women's reproductive organs. The study objective was to compare the carotenoid content in benign and malignant lesions of the breast, ovary and uterus, and to demonstrate quantitative and qualitative similarities or differences between the study groups. Materials for analysis were physiological and pathological tissues of breast, ovary and uterus. The carotenoid pigments were isolated using column chromatography (CC), thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). Sixteen carotenoids were identified in the study material, including those belonging to the provitamin A group. The most common were: beta-carotene, beta-cryptoxanthin, lutein, mutatoxanthin, violaxanthin, lutein epoxide and zeaxanthin. All the tissues subjected to analysis contained beta-carotene, 98% of the tissues had beta-cryptoxanthin, whereas alpha-carotene was detected in about 50% of breast tissue. No differences in carotenoid concentration were found between benign and malignant lesions in the examined tissues, apart from hydroxyechinenone, canthaxanthin, astaxanthin, lutein epoxide, antheraxanthin and neoxanthin. Similarly, no differences in concentration of the provitamin A carotenoids (alpha-carotene, beta-carotene, beta-cryptoxanthin, and echinenone) were found between benign and malignant lesions except hydroxyechinenone. The highest total content of carotenoids and the biggest spectrum of predominant carotenoids were found in the breast. Only in tissues of malignant lesions of the uterus, we observed statistically higher total content of carotenoids compared to remaining samples from the uterus (p<0.001) and more frequent isolation of some carotenoids (compared to benign lesions). The results of our study confirmed the presence of a high diversity of carotenoids in the physiologic, benign and malignant tissues of the breast and the reproductive tract in women. The differences observed among the frequency of isolation of some carotenoids do not allow to make straightforward conclusions. The frequent isolation of provitamin A carotenoids in the examined material and the lack of their occurrence as major carotenoids may be connected with using them in the cellular biological processes. However, this requires further investigation.
NASA Astrophysics Data System (ADS)
Park, Soo Young; Singh-Moon, Rajinder P.; Hendon, Christine P.
2018-02-01
Pulmonary vein (PV) isolation is a critical procedure for the treatment and termination of atrial fibrillation (AF). The success of such treatment depends on the extent of tissue damage, where partial lesions can allow abnormal electrical conduction and risk relapse of AF. Proper evaluation of lesion delivery and ablation line continuity remains challenging with current techniques and in part limit procedural efficacy. A tool for direct visualization of endo-myocardial lesions in vivo could potentially reduce ambiguity in treatment location and extent and improve the overall fidelity of lesion sets. In this work, we introduce a method for wide-field visualization of myocardial tissue including the discernment of ablated and non-ablated regions using an endoscopic multispectral imaging system (EMIS). The system was designed to fit the working channel of most commercial sheathes (<4 Fr) and supported quadruple-wavelength reflectance imaging through a flexible fiber-bundle. A total of 50 endocardial lesions were created and imaged on nine swine hearts, ex vivo in addition to 15 lesions on human LA samples near PV regions. A pixel-wise linear discriminant analysis algorithm was developed to classify regions of ablation treatment based on calibrated EMI maps. Results show good agreement of treatment severity and spatial extent compared to post-hoc tissue vital staining.
Evaluating coral reef health in American Samoa
Work, Thierry M.; Rameyer, Robert A.
2005-01-01
The study of coral disease has suffered from an absence of systematic approaches that are commonly used to determine causes of diseases in animals. There is a critical need to develop a standardized and portable nomenclature for coral lesions in the field and to incorporate more commonly available biomedical tools in coral disease surveys to determine the potential causes of lesions in corals. We characterized lesions in corals from American Samoa based on gross and microscopic morphology and classified them as discoloration, growth anomalies, or tissue loss. The most common microscopic finding in corals manifesting discoloration was the depletion of zooxanthellae, followed by necrosis, sometimes associated with invasive algae or fungi. The most common microscopic lesion in corals manifesting tissue loss was cell necrosis often associated with algae, fungi, or protozoa. Corals with growth anomaly had microscopic evidence of hyperplasia of gastrovascular canals, followed by necrosis associated with algae or metazoa (polychaete worms). Several species of apparently normal corals also had microscopic changes, including the presence of bacterial aggregates or crustacea in tissues. A single type of gross lesion (e.g., discoloration) could have different microscopic manifestations. This phenomenon underlines the importance of using microscopy to provide a more systematic description of coral lesions and to detect potential pathogens associated with these lesions.
Ariyarathna, Nilshan; Kumar, Saurabh; Thomas, Stuart P; Stevenson, William G; Michaud, Gregory F
2018-06-01
Adequate catheter-tissue contact facilitates efficient heat energy transfer to target tissue. Tissue contact is thus critical to achieving lesion transmurality and success of radiofrequency (RF) ablation procedures, a fact recognized more than 2 decades ago. The availability of real-time contact force (CF)-sensing catheters has reinvigorated the field of ablation biophysics and optimized lesion formation. The ability to measure and display CF came with the promise of dramatic improvement in safety and efficacy; however, CF quality was noted to have just as important an influence on lesion formation as absolute CF quantity. Multiple other factors have emerged as key elements influencing effective lesion formation, including catheter stability, lesion contiguity and continuity, lesion density, contact homogeneity across a line of ablation, spatiotemporal dynamics of contact governed by cardiac and respiratory motion, contact directionality, and anatomic wall thickness, in addition to traditional ablation indices of power and RF duration. There is greater appreciation of surrogate markers as a guide to lesion formation, such as impedance fall, loss of pace capture, and change in unipolar electrogram morphology. In contrast, other surrogates such as tactile feedback, catheter motion, and electrogram amplitude are notably poor predictors of actual contact and lesion formation. This review aims to contextualize the role of CF sensing in lesion formation with respect of the fundamental principles of biophysics of RF ablation and summarize the state-of-the-art evidence behind the role of CF in optimizing lesion formation. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Girod, Marion; Shi, Yunzhou; Cheng, Ji-Xin; Cooks, R. Graham
2010-01-01
Desorption electrospray ionization (DESI) mass spectrometry is used in an imaging mode to interrogate the lipid profiles of 15 µm thin tissues cross sections of injured rat spinal cord and normal healthy tissue. Increased relative intensities of fatty acids, diacylglycerols and lysolipids (between +120% and +240%) as well as a small decrease in intensities of lipids (−30%) were visualized in the lesion epi-center and adjacent areas after spinal cord injury. This indicates the hydrolysis of lipids during the demyelination process due to activation of phospholipase A2 enzyme. In addition, signals corresponding to oxidative degradation products, such as prostaglandin and hydroxyeicosatetraenoic acid, exhibited increased signal intensity by a factor of two in the negative ion mode in lesions relative to the normal healthy tissue. Analysis of malondialdehyde, a product of lipid peroxidation and marker of oxidative stress, was accomplished in the ambient environment using reactive DESI mass spectrometry imaging. This was achieved by electrospraying reagent solution containing dinitrophenylhydrazine as high velocity charged droplets onto the tissue section. The hydrazine reacts selectively and rapidly with the carbonyl groups of malondialdehyde and signal intensity of twice the intensity was detected in the lesions compared to healthy spinal cord. With a small amount of tissue sample, DESI-MS imaging provides information on the composition and distribution of specific compounds (limited by the occurrence of isomeric lipids with very similar fragmentation patterns) in lesions after spinal cord injury in comparison with normal healthy tissue allowing identification of the extent of the lesion and its repair. PMID:21142140
Lee, Jian-Yuan; Wang, Yining; Tang, Chuyang Y; Huo, Fengwei
2015-11-23
The efficiency of forward osmosis (FO) process is generally limited by the internal concentration polarization (ICP) of solutes inside its porous substrate. In this study, mesoporous silica gel (SG) with nominal pore size ranging from 4-30 nm was used as fillers to prepare SG-based mixed matrix substrates. The resulting mixed matrix membranes had significantly reduced structural parameter and enhanced membrane water permeability as a result of the improved surface porosity of the substrates. An optimal filler pore size of ~9 nm was observed. This is in direct contrast to the case of thin film nanocomposite membranes, where microporous nanoparticle fillers are loaded to the membrane rejection layer and are designed in such a way that these fillers are able to retain solutes while allowing water to permeate through them. In the current study, the mesoporous fillers are designed as channels to both water and solute molecules. FO performance was enhanced at increasing filler pore size up to 9 nm due to the lower hydraulic resistance of the fillers. Nevertheless, further increasing filler pore size to 30 nm was accompanied with reduced FO efficiency, which can be attributed to the intrusion of polymer dope into the filler pores.
NASA Astrophysics Data System (ADS)
Feng, Yefeng; Wu, Qin; Hu, Jianbing; Xu, Zhichao; Peng, Cheng; Xia, Zexu
2018-03-01
Interface induced polarization has a significant impact on permittivity of 0–3 type polymer composites with Si based semi-conducting fillers. Polarity of Si based filler, polarity of polymer matrix and grain size of filler are closely connected with induced polarization and permittivity of composites. However, unlike 2–2 type composites, the real permittivity of Si based fillers in 0–3 type composites could be not directly measured. Therefore, achieving the theoretical permittivity of fillers in 0–3 composites through effective medium approximation (EMA) models should be very necessary. In this work, the real permittivity results of Si based semi-conducting fillers in ten different 0–3 polymer composite systems were calculated by linear fitting of simplified EMA models, based on particularity of reported parameters in those composites. The results further confirmed the proposed interface induced polarization. The results further verified significant influences of filler polarity, polymer polarity and filler size on induced polarization and permittivity of composites as well. High self-consistency was gained between present modelling and prior measuring. This work might offer a facile and effective route to achieve the difficultly measured dielectric performances of discrete filler phase in some special polymer based composite systems.
Lee, Jian-Yuan; Wang, Yining; Tang, Chuyang Y.; Huo, Fengwei
2015-01-01
The efficiency of forward osmosis (FO) process is generally limited by the internal concentration polarization (ICP) of solutes inside its porous substrate. In this study, mesoporous silica gel (SG) with nominal pore size ranging from 4–30 nm was used as fillers to prepare SG-based mixed matrix substrates. The resulting mixed matrix membranes had significantly reduced structural parameter and enhanced membrane water permeability as a result of the improved surface porosity of the substrates. An optimal filler pore size of ~9 nm was observed. This is in direct contrast to the case of thin film nanocomposite membranes, where microporous nanoparticle fillers are loaded to the membrane rejection layer and are designed in such a way that these fillers are able to retain solutes while allowing water to permeate through them. In the current study, the mesoporous fillers are designed as channels to both water and solute molecules. FO performance was enhanced at increasing filler pore size up to 9 nm due to the lower hydraulic resistance of the fillers. Nevertheless, further increasing filler pore size to 30 nm was accompanied with reduced FO efficiency, which can be attributed to the intrusion of polymer dope into the filler pores. PMID:26592565
The formation of inflammatory demyelinated lesions in cerebral white matter
Maggi, Pietro; Cummings Macri, Sheila M.; Gaitán, María I.; Leibovitch, Emily; Wholer, Jillian E; Knight, Heather L.; Ellis, Mary; Wu, Tianxia; Silva, Afonso C.; Massacesi, Luca; Jacobson, Steven; Westmoreland, Susan; Reich, Daniel S.
2016-01-01
Objective Vascular permeability and inflammatory demyelination are intimately linked in the brain, but what is their temporal relationship? We aimed to determine the radiological correlates of the earliest tissue changes accompanying demyelination in a primate model of multiple sclerosis (MS), experimental autoimmune encephalomyelitis (EAE) in the common marmoset. Methods At 7 tesla MRI, T1 maps, proton density and T2-weighted images were acquired before and after EAE induction in 5 marmosets (every other week before lesions appeared, weekly thereafter). From scans before and after intravenous injection of contrast material, we measured the evolution of lesional blood-brain-barrier (BBB) permeability, comparing in vivo MRI to postmortem tissue examination. Results On average, BBB permeability increased 3.5 fold (p<0.0001) over the 4 weeks prior to lesion appearance. Permeability gradually decreased after lesion appearance, with attendant changes in the distribution of inflammatory cells (predominantly macrophages and microglia) and demyelination. On tissue analysis, we also identified small perivascular foci of microglia and T cells without blood-derived macrophages or demyelination. These foci had no visible MRI correlates, though permeability within the foci, but not outside, increased in the weeks before the animals died (p<0.0001). Interpretation This study provides compelling evidence that in marmoset EAE, which forms lesions strongly resembling those of MS, early changes in vascular permeability are associated with perivascular inflammatory cuffing and parenchymal microglial activation but precede the arrival of blood-derived monocytes that accompany demyelination. Prospective detection of transient permeability changes could afford an opportunity for early intervention to forestall tissue damage in newly forming lesions. PMID:25088017
The formation of inflammatory demyelinated lesions in cerebral white matter.
Maggi, Pietro; Macri, Sheila M Cummings; Gaitán, María I; Leibovitch, Emily; Wholer, Jillian E; Knight, Heather L; Ellis, Mary; Wu, Tianxia; Silva, Afonso C; Massacesi, Luca; Jacobson, Steven; Westmoreland, Susan; Reich, Daniel S
2014-10-01
Vascular permeability and inflammatory demyelination are intimately linked in the brain, but what is their temporal relationship? We aimed to determine the radiological correlates of the earliest tissue changes accompanying demyelination in a primate model of multiple sclerosis (MS), experimental autoimmune encephalomyelitis (EAE) in the common marmoset. By 7T magnetic resonance imaging (MRI), T1 maps, proton density, and T2-weighted images were acquired before and after EAE induction in 5 marmosets (every other week before lesions appeared, weekly thereafter). From scans before and after intravenous injection of contrast material, we measured the evolution of lesional blood-brain barrier (BBB) permeability, comparing in vivo MRI to postmortem tissue examination. On average, BBB permeability increased 3.5-fold (p < 0.0001) over the 4 weeks prior to lesion appearance. Permeability gradually decreased after lesion appearance, with attendant changes in the distribution of inflammatory cells (predominantly macrophages and microglia) and demyelination. On tissue analysis, we also identified small perivascular foci of microglia and T cells without blood-derived macrophages or demyelination. These foci had no visible MRI correlates, although permeability within the foci, but not outside, increased in the weeks before the animals died (p < 0.0001). This study provides compelling evidence that in marmoset EAE, which forms lesions strongly resembling those of MS, early changes in vascular permeability are associated with perivascular inflammatory cuffing and parenchymal microglial activation but precede the arrival of blood-derived monocytes that accompany demyelination. Prospective detection of transient permeability changes could afford an opportunity for early intervention to forestall tissue damage in newly forming lesions. © 2014 American Neurological Association.
Focal cemento-osseous dysplasia of mandible
Cankaya, Abdülkadir Burak; Erdem, Mehmet Ali; Olgac, Vakur; Firat, Deniz Refia
2012-01-01
Fibro-osseous lesions are disturbances in bone metabolism in which normal bone is replaced by a connective tissue matrix that then gradually develops into cemento-osseous tissue. Typically, the lesion is asymptomatic and is detected on routine radiographic examination. Radiologically, this lesion has three stages of maturation: pure radiolucent, radiopaque/mixed radiolucent, and radiopaque appearance. During these stages the lesion can be misdiagnosed. In this case report a 69-year- old patient with a a complaint of painless swelling of the left mandibular molar and premolar area is presented along with a review of the differential diagnoses considered in order to reach a final diagnosis of focal cemento-osseous dysplasia. PMID:22948991
Focal cemento-osseous dysplasia of mandible.
Cankaya, Abdülkadir Burak; Erdem, Mehmet Ali; Olgac, Vakur; Firat, Deniz Refia
2012-09-03
Fibro-osseous lesions are disturbances in bone metabolism in which normal bone is replaced by a connective tissue matrix that then gradually develops into cemento-osseous tissue. Typically, the lesion is asymptomatic and is detected on routine radiographic examination. Radiologically, this lesion has three stages of maturation: pure radiolucent, radiopaque/mixed radiolucent, and radiopaque appearance. During these stages the lesion can be misdiagnosed. In this case report a 69-year- old patient with a a complaint of painless swelling of the left mandibular molar and premolar area is presented along with a review of the differential diagnoses considered in order to reach a final diagnosis of focal cemento-osseous dysplasia.
Gao, Mingxuan; Li, Hong; Liang, Xiaoyan; Fu, Xiaoyan; Li, Xusheng
2017-07-06
Pigmented villonodular synovitis (PVNS) is an uncommon entity of proliferative lesion of the synovium, presenting with different clinical signs and symptoms. PVNS rarely forms an osteolytic lesion in a bone. Here we report a unique case of PVNS with a nodular lesion in the left patella. A 37-year-old female was referred to our hospital with complaints of ongoing left knee pain and a painful and palpable mass in her left popliteal fossa. MRI demonstrated a nodular lesion in the left patella, diffuse affected synovial tissue in the left knee and an extra-articular mass in the left popliteal fossa. After a primary diagnosis of PVNS had been established, combined arthroscopic synovectomy and open resection were performed. The postoperative pathological diagnoses of the resected mass from the popliteal fossa, the affected synovial tissue and the lesion in the patella were consistent with PVNS. At 1-year follow-up, no evidence of recurrence was noted. Based on brief literature review of PNVS, we presented a very rare case of PVNS with a nodular lesion in the left patella, diffuse affected synovial tissue in the left knee and an extra-articular mass in the left popliteal fossa.
The effect of filler on the protein content and interferences in rubber latices
NASA Astrophysics Data System (ADS)
Ruhida, A. R.; Hassan, Aziz
2017-12-01
It is well known that the application of commercial fillers like calcium carbonate has widely been used in natural rubber latex (NRL) gloves as well as other dipped products such as balloons, condom and catheters. The main reason of adding the fillers into the rubber compound was as cheapening aid and to improve the end-product properties. Due to its functional benefit, many studies have been conducted on the application and beneficial usage of fillers in natural rubber (NR) compounds and natural rubber latex (NRL) dipped goods namely gloves. However most of the studies were basically emphasizing on the effect of fillers on the physical properties and surface morphology of rubber. Not many studies have been conducted to investigate the effect of filler on the protein content in NRL products. Earlier work by other workers has only been concentrating on the effect of nano-sized calcium carbonate fillers in NR latex gloves. Because of the concern on the issue of latex protein allergy; it is thus important to study the effect of filler on protein content and its interferences in the rubber lattices. This paper will seek to elaborate on the effect of filler content on the total protein and extractable protein (EP) content of NR latex films at various filler loadings before and after ageing. The effect of interferences by filler that was mixed into the NR latex on the total nitrogen and EP content were also measured and shown.
A systematic review of dermal fillers for age-related lines and wrinkles.
Sturm, Lana P; Cooter, Rodney D; Mutimer, Keith L; Graham, John C; Maddern, Guy J
2011-01-01
Dermal fillers are gaining popularity for rapid aesthetic improvement. Long-term efficacy and safety have not been well documented. The aim of this systematic review was to assess the safety and efficacy of injectable dermal fillers compared with other facial augmentation techniques for the management of age-related lines and wrinkles. Studies including patients receiving injectable semi-permanent or permanent dermal fillers for age-related lines and wrinkles were included in this review. Efficacy outcomes (including changes in skin thickness and patient satisfaction) and safety outcomes (including mortality, lumps and infections) were examined. Three randomized control trials and six case series were included. Permanent and semi-permanent dermal fillers improved subjective ratings of appearance and resulted in higher patient satisfaction than temporary fillers. Long-term efficacy appeared good in the few studies that reported it. Short-term safety appeared favourable. Lumps were reported in all but one study but received little follow-up. Long-term safety data were limited. The treatment of age-related lines and wrinkles with permanent and semi-permanent dermal fillers is more efficacious compared with temporary fillers in those studies that compared them. Case series evidence suggests that these fillers achieve their objective, which is to decrease the visible effects of age-related changes. These fillers appear at least as safe as temporary fillers in the short term in those studies that compared them. Long-term safety could not be determined. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.
Vergara, Gaston R; Vijayakumar, Sathya; Kholmovski, Eugene G; Blauer, Joshua J E; Guttman, Mike A; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W; Daccarett, Marcos; McGann, Christopher J; Macleod, Rob S; Marrouche, Nassir F
2011-02-01
Magnetic resonance imaging (MRI) allows visualization of location and extent of radiofrequency (RF) ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT -RI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. The purpose of this study was to develop a 3-Tesla RT MRI-based catheter ablation and lesion visualization system. RF energy was delivered to six pigs under RT MRI guidance. A novel MRI-compatible mapping and ablation catheter was used. Under RT MRI, this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bipolar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2W) half Fourier acquisition with single-shot turbo spin echo (HASTE) sequence during ablation. RT visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or the lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement MRI and macroscopic tissue examination. MRI-compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT MRI guidance. Recording electrograms during RT imaging also is feasible. RT visualization of lesion as it forms during RF energy delivery is possible and was demonstrated using T2W HASTE imaging. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
REAL TIME MRI GUIDED RADIOFREQUENCY ATRIAL ABLATION AND VISUALIZATION OF LESION FORMATION AT 3-TESLA
Vergara, Gaston R.; Vijayakumar, Sathya; Kholmovski, Eugene G.; Blauer, Joshua J.E.; Guttman, Mike A.; Gloschat, Christopher; Payne, Gene; Vij, Kamal; Akoum, Nazem W.; Daccarett, Marcos; McGann, Christopher J.; MacLeod, Rob S.; Marrouche, Nassir F.
2011-01-01
Background MRI allows visualization of location and extent of RF ablation lesion, myocardial scar formation, and real-time (RT) assessment of lesion formation. In this study, we report a novel 3-Tesla RT-MRI based porcine RF ablation model and visualization of lesion formation in the atrium during RF energy delivery. Objective To develop of a 3-Tesla RT-MRI based catheter ablation and lesion visualization system. Methods RF energy was delivered to six pigs under RT-MRI guidance. A novel MRI compatible mapping and ablation catheter was used. Under RT-MRI this catheter was safely guided and positioned within either the left or right atrium. Unipolar and bi-polar electrograms were recorded. The catheter tip-tissue interface was visualized with a T1-weighted gradient echo sequence. RF energy was then delivered in a power-controlled fashion. Myocardial changes and lesion formation were visualized with a T2-weighted (T2w) HASTE sequence during ablation. Results Real-time visualization of lesion formation was achieved in 30% of the ablations performed. In the other cases, either the lesion was formed outside the imaged region (25%) or lesion was not created (45%) presumably due to poor tissue-catheter tip contact. The presence of lesions was confirmed by late gadolinium enhancement (LGE) MRI and macroscopic tissue examination. Conclusion MRI compatible catheters can be navigated and RF energy safely delivered under 3-Tesla RT-MRI guidance. It is also feasible to record electrograms during RT imaging. Real-time visualization of lesion as it forms during delivery of RF energy is possible and was demonstrated using T2w HASTE imaging. PMID:21034854
Robson, Holly; Specht, Karsten; Beaumont, Helen; Parkes, Laura M; Sage, Karen; Lambon Ralph, Matthew A; Zahn, Roland
2017-07-01
Behavioural impairment post-stroke is a consequence of structural damage and altered functional network dynamics. Hypoperfusion of intact neural tissue is frequently observed in acute stroke, indicating reduced functional capacity of regions outside the lesion. However, cerebral blood flow (CBF) is rarely investigated in chronic stroke. This study investigated CBF in individuals with chronic Wernicke's aphasia (WA) and examined the relationship between lesion, CBF and neuropsychological impairment. Arterial spin labelling CBF imaging and structural MRIs were collected in 12 individuals with chronic WA and 13 age-matched control participants. Joint independent component analysis (jICA) investigated the relationship between structural lesion and hypoperfusion. Partial correlations explored the relationship between lesion, hypoperfusion and language measures. Joint ICA revealed significant differences between the control and WA groups reflecting a large area of structural lesion in the left posterior hemisphere and an associated area of hypoperfusion extending into grey matter surrounding the lesion. Small regions of remote cortical hypoperfusion were observed, ipsilateral and contralateral to the lesion. Significant correlations were observed between the neuropsychological measures (naming, repetition, reading and semantic association) and the jICA component of interest in the WA group. Additional ROI analyses found a relationship between perfusion surrounding the core lesion and the same neuropsychological measures. This study found that core language impairments in chronic WA are associated with a combination of structural lesion and abnormal perfusion in non-lesioned tissue. This indicates that post-stroke impairments are due to a wider disruption of neural function than observable on structural T1w MRI. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Postanesthetic ulceration of palate: A rare complication.
Gupta, Ramesh; Garg, Meenu; Pawah, Salil; Gupta, Ajay
2016-01-01
The routine dental practice involves various dental procedures which needs the application of local anesthetics. Generally, there are very few complications associated with these procedures. Complications such as tissue necrosis can occur following the rapid injection of local anesthetic solutions. Palate is a favorable site for soft tissue lesions, various factors such as direct effects of the drug, blanching of the tissues during injection, a relatively poor blood supply, and reactivation of the latent forms of herpes can all promote to tissue ischemia and a lesion in the palate.
Postanesthetic ulceration of palate: A rare complication
Gupta, Ramesh; Garg, Meenu; Pawah, Salil; Gupta, Ajay
2016-01-01
The routine dental practice involves various dental procedures which needs the application of local anesthetics. Generally, there are very few complications associated with these procedures. Complications such as tissue necrosis can occur following the rapid injection of local anesthetic solutions. Palate is a favorable site for soft tissue lesions, various factors such as direct effects of the drug, blanching of the tissues during injection, a relatively poor blood supply, and reactivation of the latent forms of herpes can all promote to tissue ischemia and a lesion in the palate. PMID:28163486
Acute fatal toxoplasmosis in squirrels (Sciurus carolensis) with bradyzoites in visceral tissues.
Dubey, J P; Hodgin, E C; Hamir, A N
2006-06-01
Acute toxoplasmosis was diagnosed in 3 gray squirrels (Sciurus carolensis) from Louisiana and Pennsylvania. The predominant lesion was multifocal necrosis in several organs, especially of the lymph nodes. Numerous Toxoplasma gondii tachyzoites were seen in lesions, and the diagnosis was confirmed immunohistochemically by reaction with polyclonal T. gondii-specific antibodies. Tissue cysts were seen in several organs, including lung alveoli. The presence of tissue cysts in alveoli of pet squirrels maybe of public health concern if tissue cysts excreted in nasal secretions are swallowed by children.
Spontaneous melanotic lesions in axillary seabream, Pagellus acarne (Risso).
Ramos, P; Victor, P; Branco, S
2013-09-01
In this article, we describe spontaneous melanotic lesions in the skin of axillary seabream, Pagellus acarne (Risso), from a defined area of the Portuguese Coast, located in Cabo da Roca and Foz do Arelho. The lesions corresponded to the black pigmentation spots on the skin of the head, fins, lips and conjunctiva and, additionally, black nodules on the skin of the head and lips. In some specimens, the nodular formations in the head changed their anatomical conformation. Histologically, there were melanophores scattered along the basement membrane or forming aggregates in the dermis, infiltrating the subcutaneous tissue but not invading the adjacent muscle tissue. The aim of this study was to characterize the macroscopic and microscopic features of the pigmented lesions. These fish show sessile hyperpigmented lesions (spots) that correspond to proliferative lesions of melanophores in the dermis and nodular lesions that correspond to neoplastic lesions, melanophoromas. The melanophores in such lesions showed high concentration of melanin in the cytoplasm, moderate pleomorphism and compact distribution throughout all of the dermis. © 2013 John Wiley & Sons Ltd.
Clinical evaluation of improvised gauze-based negative pressure wound therapy in military wounds.
Mansoor, Junaid; Ellahi, Irfan; Junaid, Zartash; Habib, Adeel; Ilyas, Uzair
2015-10-01
The use of negative pressure wound therapy (NPWT) in civilian and military wounds is found effective in promoting granulation tissue, decreasing exudate and improving patient comfort. The Use of gauze-based NPWT is increasing in civilian trauma cases with availability of proprietary systems using gauze as filler material rather than the traditionally used reticulated open-cell foam. Military trauma wounds differ from civilian trauma wounds in energy of impact, degree and nature of contamination as well as the hostile environments. The Use of gauze as filler material for NPWT in military trauma wounds is less well studied. This study is a retrospective analysis of use of improvised gauze-based NPWT in military trauma wounds. The whole assembly was constructed from commonly available operation theatre supplies and no proprietary system was used. Results were very encouraging and the use of this improvised method can be useful and cheap alternative to costly proprietary systems. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Cerqua, Sandro; Angelucci, Francesco
2013-08-01
In a minority of patients undergoing liposuction, superficial irregularities (or skin depression) in the operated area may occur. Macrolane is a gel composed of hyaluronic acid (HA), used for volume restoration of soft tissues. In this study, the authors investigated the effectiveness, maintenance, and safety of Macrolane as a "non-surgical" treatment to correct skin depression after liposuction. Twelve female patients were included. Macrolane was injected at a subdermal superficial plane using an intramuscular or spinal needle. In all patients, Macrolane was successful in correcting skin depression. No relevant side effects were observed. At 8 months post-injection, a persistence of correction of 60-70% was still present in 90% of the patients. In conclusion, Macrolane filler injections are a predictable, safe, and long-lasting non-surgical procedure to fill contour defects that arise after liposuction, and represent a good option for patients who refuse to undergo an additional surgery to fill the arisen skin depressions.
Nódulos subcutáneos faciales de 3 meses de evolución.
Martinez-Lopez, Antonio; Pérez-Lopez, Israel; Sánchez-Cano, Daniel; Ruiz-Villaverde, Ricardo
2017-02-15
Siliconomas are subcutaneous nodules that usuallyappear as a consequence of the migration of freesilicon implanted in other locations. They are morefrequent in women with abnormal breast implants,such as poly implant prostheses (PIP), but they may alsoappear after illegal injection of free silicone. We reporta 57-year-old woman who attended our Dermatologyclinic complaining of relapsing facial panniculitis ofunknown origin. After a thorough work-up, thesenodules were determined to be the consequence ofdermal filler made with fluid silicone, which had beeninjected 20 years prior. High frequency skin ultrasoundof one of the nodules showed a hyperechoic image,also known as "snowstorm," which was located in thesubcutaneous tissue. The disposition of silicone in thisplane obscures the view of any sonographic structurein the underlying plane. Cutaneous sonographyhas become one of the most useful non-invasivetechniques in diagnosis of filler complications andother inflammatory diseases. Combined treatmentwith prednisone and allopurinol was successful, withno recurrence after 1 year of follow-up.
Wang, Zhengzhi; Chiang, Martin Y M
2016-04-01
The effect of filler content in dental restorative composites on the polymerization shrinkage stress (PS) is not straightforward and has caused much debate in the literature. Our objective in this study was to clarify the PS/filler content relationship based on analytical and experimental approaches, so that guidelines for materials comparison in terms of PS and clinical selection of dental composites with various filler content can be provided. Analytically, a simplified model based on linear elasticity was utilized to predict PS as a function of filler content under various compliances of the testing system, a cantilever beam-based instrument used in this study. The predictions were validated by measuring PS of composites synthesized using 50/50 mixtures of two common dimethacrylate resins with a variety of filler contents. Both experiments and predictions indicated that the influence of filler content on the PS highly depended on the compliance of the testing system. Within the clinic-relevant range of compliances and for the specific sample configuration tested, the PS increased with increasing filler content at low compliance of instrument, while increasing the compliance caused the effect of filler content on the PS to gradually diminish. Eventually, at high compliance, the PS inverted and decreased with increasing filler content. This compliance-dependent effect of filler content on PS suggests: (1) for materials comparison in terms of PS, the specific compliance at which the comparison being done should always be reported and (2) clinically, composites with relatively lower filler content could be selected for such cavities with relatively lower compliance (e.g. a Class-I cavity with thick tooth walls or the basal part in a cavity) and vice versa in order to reduce the final PS. Published by Elsevier Ltd.
Evaluation of Different Mineral Filler Aggregates for Asphalt Mixtures
NASA Astrophysics Data System (ADS)
Wasilewska, Marta; Małaszkiewicz, Dorota; Ignatiuk, Natalia
2017-10-01
Mineral filler aggregates play an important role in asphalt mixtures because they fill voids in paving mix and improve the cohesion of asphalt binder. Limestone powder containing over 90% of CaCO3 is the most frequently used type of filler. Waste material from the production of coarse aggregate can be successfully used as a mineral filler aggregate for hot asphalt concrete mixtures as the limestone powder replacement. This paper presents the experimental results of selected properties of filler aggregates which were obtained from rocks with different mineral composition and origin. Five types of rocks were used as a source of the mineral filler aggregate: granite, gabbro, trachybasalt, quartz sandstone and rocks from postglacial deposits. Limestone filler was used in this study as the reference material. The following tests were performed: grading (air jet sieving), quality of fines according to methylene blue test, water content by drying in a ventilated oven, particle density using pyknometer method, Delta ring and ball test, Bitumen Number, fineness determined as Blaine specific surface area. Mineral filler aggregates showed significant differences when they were mixed with bitumen and stiffening effect in Delta ring and ball test was evaluated. The highest values were achieved when gabbro and granite fillers were used. Additionally, Scanning Electron Microscopy (SEM) analysis of grain shape and size was carried out. Significant differences in grain size and shape were observed. The highest non-homogeneity in size was determined for quartz sandstone, gabbro and granite filler. Their Blaine specific surface area was lower than 2800 cm2/g, while for limestone and postglacial fillers with regular and round grains it exceeded 3000 cm2/g. All examined mineral filler aggregates met requirements of Polish National Specification WT-1: 2014 and could be used in asphalt mixtures.
Halimi, C; Montembault, A; Guerry, A; Delair, T; Viguier, E; Fulchiron, R; David, L
2015-01-01
A new generation of dermal filler for wrinkle filler based on chitosan was compared to current hyaluronic acid-based dermal fillers by using a new rheological performance criterion based on viscosity during injection related to Newtonian viscosity. In addition an in vivo evaluation was performed for preclinical evidence of chitosan use as dermal filler. In this way, biocompatibility and dermis reconstruction was evaluated on a pig model.
Kolandaivelu, Aravindan; Zviman, Menekhem M.; Castro, Valeria; Lardo, Albert C.; Berger, Ronald D.; Halperin, Henry R.
2010-01-01
Background Failure to achieve properly localized, permanent tissue destruction is a common cause of arrhythmia recurrence after cardiac ablation. Current methods of assessing lesion size and location during cardiac radiofrequency ablation are unreliable or not suited for repeated assessment during the procedure. MRI thermography could be used to delineate permanent ablation lesions because tissue heating above 50°C is the cause of permanent tissue destruction during radiofrequency ablation. However, image artifacts caused by cardiac motion, the ablation electrode, and radiofrequency ablation currently pose a challenge to MRI thermography in the heart. In the current study, we sought to demonstrate the feasibility of MRI thermography during cardiac ablation. Methods and Results An MRI-compatible electrophysiology catheter and filtered radiofrequency ablation system was used to perform ablation in the left ventricle of 6 mongrel dogs in a 1.5-T MRI system. Fast gradient-echo imaging was performed before and during radiofrequency ablation, and thermography images were derived from the preheating and postheating images. Lesion extent by thermography was within 20% of the gross pathology lesion. Conclusions MR thermography appears to be a promising technique for monitoring lesion formation and may allow for more accurate placement and titration of ablation, possibly reducing arrhythmia recurrences. PMID:20657028
Linear lesions in heart tissue using diffused laser radiation
NASA Astrophysics Data System (ADS)
Fried, Nathaniel M.; Lardo, Albert C.; Berger, Ronald D.; Calkins, Hugh; Halperin, Henry R.
2000-05-01
Transmural, continuous, and linear lesions may be necessary for successful catheter ablation of cardiac arrythmias such as atrial fibrillation. Laser ablation was studied as an alternative to radiofrequency ablation, which is noted to produce superficial and discontinuous lesions as well as tissue charring and vaporization. Samples of canine myocardium were placed in a saline bath and irradiated with an 1.06- micrometer Nd:YAG laser operated in either pulsed or continuous mode. For pulsed mode, the laser pulse duration was 10 s with 10 s cooling between pulses. Laser radiation was delivered radially through diffusing optical fiber tips oriented parallel to the endocardial surface. In CW mode, transmural (6-mm-deep), linear (16-mm-long), and continuous lesions were produced using a laser power of 30 W and an irradiation time of 180 s. Peak tissue temperatures measured 51 plus or minus 1 degree Celsius at the endocardial surface, 61 plus or minus 6 degrees Celsius in the mid-myocardium, and 55 plus or minus 6 degree Celsius at the epicardial surface. There was no evidence of tissue charring or vaporization. Pulsed laser irradiation produced comparable lesion depths to CW irradiation with more uniform heating of the subsurface myocardium, but at the expense of longer operation times. Further in vivo study of laser ablation is warranted for possible clinical applications.
Xu, Xue-qing; Yu, Le; Liu, Shu-wen
2011-06-01
To examine the protective effects of wasp (Vespa magnifica) honeycomb extract (WCE) against gastric lesions in rats induced by 60% acidified ethanol, and evaluate its capacity to suppress oxidative stress in the gastric tissue. Wistar rats were subjected to intragastric administration of 60% acidified ethanol to induce gastric lesions following an 8-day oral pretreatment with WCE at 0, 25, 100 and 150 mg/kg or with saline. The levels of 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging, myeloperoxidase (MPO) activity and total antioxidant capacity in the gastric tissues were determined. Oral administration of 25, 100 and 150 mg/kg WCE prior to 60% acidified ethanol administration significantly inhibited the formation of gastric lesions (with a reduction by 44.2%-87.1%), decreased the mucosal MPO activity (by 16.4%-56.6%) and increased the total antioxidant capacity of the gastric tissue (by 0.5, 1.47 and 1.83 folds, respectively) in a dose-dependent manner. At a high concentration (above 1 mg/ml), WCE also exhibited a stronger DPPH radical scavenging activity than butylated hydroxytoluene (BHT). The ethanol extract of wasp honeycombs can suppress the formation of acidified ethanol-induced gastric lesions by reducing free radical oxidation and neutrophils infiltration in the gastric tissue in rats.
Wilson, Erin; Rapues, Jenna; Jin, Harry; Raymond, H. Fisher
2014-01-01
Introduction There is a dearth of studies to quantify the use of illicit fillers by transwomen. Case studies of illicit filler injections have pointed to an array of serious health complications, including death. Aim The aim of this study was to determine the population prevalence of filler use among transwomen, and to identify correlations with filler use. Methods An analysis of data collected in 2013 with a population-based sample of 234 transwomen recruited using respondent driven sampling (RDS). We used RDS weights to conduct bivariate and multivariate analyses of correlates of filler use. Main Outcome measures Main outcome measures were an RDS-weighted population prevalence of filler use among transwomen and differences in demographic characteristics, transition-related care factors and self-esteem related to appearance. Results Weighted filler prevalence among transwomen was 16.7%. Being a transwomen between 30–49 years of age, owning/renting or living with a partner/family/friend, having had and planning to have surgery in the future and having used non-prescribed hormones were all associated with filler use. HIV was not associated with filler use. Conclusions This study provides the first known estimate to date of the prevalence of filler use in a population-based sample of transwomen in San Francisco. Accessing illicit fillers may be the only choice available for many transwomen due to the cost of legal surgeries and other procedures to change one’s appearance. An important next step in this research is to determine the overall prevalence and long-term consequences of filler use among transwomen, to explore how the use of fillers is protective to the safety and wellbeing of transwomen, and to find safe and affordable alternatives to this method that meets important gender-related appearance needs. PMID:24810672
Chun, Cheolbyong; Lee, Deuk Yong; Kim, Jin-Tae; Kwon, Mi-Kyung; Kim, Young-Zu; Kim, Seok-Soon
2016-01-01
Hyaluronic acid (HA) dermal biphasic fillers are synthesized for their efficacy in correcting aesthetic defects such as wrinkles, scars and facial contouring defects. The fillers consist of crosslinked HA microspheres suspended in a noncrosslinked HA. To extend the duration of HAs within the dermis and obtain the particle texturing feel, HAs are crosslinked to obtain the suitable mechanical properties. Hyaluronic acid (HA) dermal biphasic fillers are prepared by mixing the crosslinked HA microspheres and the noncrosslinked HAs. The elastic modulus of the fillers increased with raising the volume fraction of the microspheres. The mechanical properties and the particle texturing feel of the fillers made from crosslinked HA (1058 kDa) microspheres suspended in noncrosslinked HA (1368 kDa) are successfully achieved, which are adequate for the fillers. Dermal biphasic HA fillers made from 1058 kDa exhibit suitable elastic moduli (211 to 420 Pa) and particle texturing feel (scale 7 ~ 9).
Orbiter Gap Filler Bending Model for Re-entry
NASA Technical Reports Server (NTRS)
Campbell, Charles H.
2007-01-01
Pressure loads on a protruding gap filler during an Orbiter reentry are investigated to evaluate the likelihood of extraction due to pressure loads, and to ascertain how much bending will be induced by re-entry pressure loads. Oblique shock wave theory is utilized to develop a representation of the pressure loads induced on a gap filler for the ISSHVFW trajectory, representative of a heavy weight ISS return. A free body diagram is utilized to react the forces induced by the pressure forces. Preliminary results developed using these methods demonstrate that pressure loads, alone, are not likely causes of gap filler extraction during reentry. Assessment of the amount a gap filler will bend over is presented. Implications of gap filler bending during re-entry include possible mitigation of early boundary layer transition concerns, uncertainty in ground based measurement of protruding gap fillers from historical Orbiter flight history, and uncertainty in the use of Orbiter gap fillers for boundary layer prediction calibration. Authors will be added to the author list as appropriate.
Morel, O; Monceau, E; Tran, N; Malartic, C; Morel, F; Barranger, E; Côté, J F; Gayat, E; Chavatte-Palmer, P; Cabrol, D; Tsatsaris, V
2009-06-01
To evaluate radiofrequency (RF) efficiency and safety for the ablation of retained placenta in humans, using a pregnant sheep model. Experimental study. Laboratory of Surgery School, Nancy, France. Three pregnant ewes/ten human placentas. Various RF procedures were tested in pregnant ewes on 50 placentomes (individual placental units). Reproducibility of the best procedure was then evaluated in a further 20 placentomes and on ten human term placentas in vitro after delivery. Placental tissues destruction, lesions' size, myometrial lesions. Low power (100 W) and low target temperatures (60 degrees C) lead to homogenous tissue destruction, without myometrial lesion. No significant difference was observed in terms of lesion size and procedure duration for in the placentomes of pregnant ewe in vivo and in human placentas in vitro. The diameter of the ablation could be correlated with the tines deployment. The placental tissue structure is very permissive to RF energy, which suggests that RF could be used for the ablation of retained placenta, providing optimal control of tissue destruction. These results call for further experimental evaluations.
Gurav, Abhijit Ningappa; Shete, Abhijeet Rajendra; Naiktari, Ritam
2015-01-01
Periradicular (PR) bone defects are common sequelae of chronic endodontic lesions. Sometimes, conventional root canal therapy is not adequate for complete resolution of the lesion. PR surgeries may be warranted in such selected cases. PR surgery provides a ready access for the removal of pathologic tissue from the periapical region, assisting in healing. Recently, the regeneration of the destroyed PR tissues has gained more attention rather than repair. In order to promote regeneration after apical surgery, the principle of guided tissue regeneration (GTR) has proved to be useful. This case presents the management of a large PR lesion in a 42-year-old male subject. The PR lesion associated with 21, 11 and 12 was treated using GTR membrane, fixated with titanium minipins. The case was followed up for 2 years radiographically, and a surgical re-entry confirmed the re-establishment of the lost labial plate. Thus, the principle of GTR may immensely improve the clinical outcome and prognosis of an endodontically involved tooth with a large PR defect. PMID:26941526
Gurav, Abhijit Ningappa; Shete, Abhijeet Rajendra; Naiktari, Ritam
2015-01-01
Periradicular (PR) bone defects are common sequelae of chronic endodontic lesions. Sometimes, conventional root canal therapy is not adequate for complete resolution of the lesion. PR surgeries may be warranted in such selected cases. PR surgery provides a ready access for the removal of pathologic tissue from the periapical region, assisting in healing. Recently, the regeneration of the destroyed PR tissues has gained more attention rather than repair. In order to promote regeneration after apical surgery, the principle of guided tissue regeneration (GTR) has proved to be useful. This case presents the management of a large PR lesion in a 42-year-old male subject. The PR lesion associated with 21, 11 and 12 was treated using GTR membrane, fixated with titanium minipins. The case was followed up for 2 years radiographically, and a surgical re-entry confirmed the re-establishment of the lost labial plate. Thus, the principle of GTR may immensely improve the clinical outcome and prognosis of an endodontically involved tooth with a large PR defect.
Cemento-ossifying fibroma in a patient with end-stage renal disease.
Gopinath, Divya; Beena, V T; Sugirtharaj, G; Vidhyadharan, K; Salmanul Faris, K; Kumar, Sajai J
2013-01-01
The presence of chronic renal disease (CRD) is a predisposing factor for the occurrence of soft and hard tissue lesions in the oral cavity. The cemento-ossifying fibroma (COF) is an uncommon benign fibroosseous lesion composed of fibrocellular component and calcified materials like cementum and woven bone. A 37-year-old female patient undergoing chronic haemodialysis reported to our institution with a complaint of slow growing, nontender swelling of mandible of 6-month duration. Computed tomography disclosed an ill-defined lesion showing thinning and expansion of buccal as well as lingual cortical plate with flecks of radiopacity in centre. Incision biopsy revealed histological characteristics consistent with cemento-ossifying fibroma. The lesion was excised under local anesthesia. The histopathological examination revealed irregularly shaped bone and cementum-like hard tissue calcifications contained within hypercellular fibrous tissue stroma, leading to a confirmation of the diagnosis of cemento-ossifying fibroma. This paper aims to provide light to the fact that the soft and hard tissues of the oral region may become susceptible to the development of pathological growths in case of some particular systemic conditions.
Cemento-Ossifying Fibroma in a Patient with End-Stage Renal Disease
Gopinath, Divya; Beena, V. T.; Sugirtharaj, G.; Vidhyadharan, K.; Salmanul Faris, K.; Kumar, Sajai J.
2013-01-01
The presence of chronic renal disease (CRD) is a predisposing factor for the occurrence of soft and hard tissue lesions in the oral cavity. The cemento-ossifying fibroma (COF) is an uncommon benign fibroosseous lesion composed of fibrocellular component and calcified materials like cementum and woven bone. A 37-year-old female patient undergoing chronic haemodialysis reported to our institution with a complaint of slow growing, nontender swelling of mandible of 6-month duration. Computed tomography disclosed an ill-defined lesion showing thinning and expansion of buccal as well as lingual cortical plate with flecks of radiopacity in centre. Incision biopsy revealed histological characteristics consistent with cemento-ossifying fibroma. The lesion was excised under local anesthesia. The histopathological examination revealed irregularly shaped bone and cementum-like hard tissue calcifications contained within hypercellular fibrous tissue stroma, leading to a confirmation of the diagnosis of cemento-ossifying fibroma. This paper aims to provide light to the fact that the soft and hard tissues of the oral region may become susceptible to the development of pathological growths in case of some particular systemic conditions. PMID:23819070
Zhao, Jing; Feng, Lijuan; Dai, Jincheng; Yang, Guangfeng; Mu, Jun
2017-12-01
Each kind of conventional plastic filler (polyurethane filler, SPR-1 suspension filler, TA-II elastic filler and sphere filler) coupled with alkaline pretreated corncob (A.H.corncob) was applied in each bioreactor system for treating polluted water with nitrate and organics. Results demonstrated that addition of A.H.corncob could achieve simultaneous removal of nitrogen and organics, and coupling of SPR-1 suspension filler with A.H.corncob (R 2 ) had the best performance. In coupling system of R 2 , the total nitrogen (TN) removal rate improved from below 10% to 55.92 ± 18.27% with effluent COD Mn concentration maintaining at a low level of 2.67 ± 0.44 mg L -1 . Microbial analysis of combined filler system demonstrated that conventional plastic filler mainly accumulated non-solid-phase denitrifiers for both nitrate and organics removal including genera Salipiger, Enterobacteriaceae etc. while A.H.corncob carrier was stronghold of solid-phase denitrifiers (Runella, etc.) directly using lignocellulosic materials as carbon source and fermentative bacteria (Coprococcus, etc.) for supplementing available carbon sources for denitrifiers in the system, which were integrated to achieve simultaneous removal of nitrate and organics.
Jaarda, M J; Lang, B R; Wang, R F; Edwards, C A
1993-04-01
Composite resins are routinely classified on the basis of filler particle size for purposes of research, clinical applications, and communications. The size and characterizations of filler particles have also been considered a significant factor in the rate of wear of composites. Making valid correlations between the filler particles within a composite and wear requires accuracy of filler particle size and characterization. This study was initiated to examine two methods that would (1) qualify the filler particle content of a composite resin and (2) quantify the number, size, and the area occupied by the filler particles in composite resins. Three composite resins, BIS-FIL I, Visio-Fil, and Ful-Fil, were selected as the materials to be examined, on the basis of their published composite classification type as fine particle. The findings demonstrated that scientific methods are available to examine qualitatively and measure quantitatively the composite resin filler particles in terms of their numbers, sizes, and area occupied by use of a scanning electron microscope and digital imaging. Significant differences in the filler particle numbers, sizes, and the area occupied were found for the three composite resins in this study that were classified as fine particle.
Influence of filler loading on the two-body wear of a dental composite.
Hu, X; Marquis, P M; Shortall, A C
2003-07-01
The purpose of the study was to explore the fundamental wear behaviour of a dental composite with different filler loadings under two-body wear conditions. The parent resin and filler components were mixed according to different weight ratios to produce experimental composites with filler loadings ranging from 20 to 87.5% by weight. A two-body wear test was conducted on the experimental composites using a wear-testing machine. The machine was designed to simulate the impact of the direct cyclic masticatory loading that occurs in the occlusal contact area in vivo. The results showed that there was little increase in the rate of wear with filler loadings below 60 wt%, but a sharp increase between 80 and 87.5 wt% in filler loading. Wide striations and bulk loss of material were apparent on the wear surfaces at higher filler loadings. Coefficients of friction increased with filler loading and followed the increase in rate of wear loss closely. It was concluded that, under two-body wear conditions, addition of high levels of filler particles into the resin matrix could reduce the wear resistance of dental composites. This finding may help when designing future dental composites for use in particular clinical settings.
Mechanical Properties of Epoxy Resin Mortar with Sand Washing Waste as Filler.
Yemam, Dinberu Molla; Kim, Baek-Joong; Moon, Ji-Yeon; Yi, Chongku
2017-02-28
The objective of this study was to investigate the potential use of sand washing waste as filler for epoxy resin mortar. The mechanical properties of four series of mortars containing epoxy binder at 10, 15, 20, and 25 wt. % mixed with sand blended with sand washing waste filler in the range of 0-20 wt. % were examined. The compressive and flexural strength increased with the increase in epoxy and filler content; however, above epoxy 20 wt. %, slight change was seen in strength due to increase in epoxy and filler content. Modulus of elasticity also linearly increased with the increase in filler content, but the use of epoxy content beyond 20 wt. % decreased the modulus of elasticity of the mortar. For epoxy content at 10 wt. %, poor bond strength lower than 0.8 MPa was observed, and adding filler at 20 wt. % adversely affected the bond strength, in contrast to the mortars containing epoxy at 15, 20, 25 wt. %. The results indicate that the sand washing waste can be used as potential filler for epoxy resin mortar to obtain better mechanical properties by adding the optimum level of sand washing waste filler.
Mechanical Properties of Epoxy Resin Mortar with Sand Washing Waste as Filler
Yemam, Dinberu Molla; Kim, Baek-Joong; Moon, Ji-Yeon; Yi, Chongku
2017-01-01
The objective of this study was to investigate the potential use of sand washing waste as filler for epoxy resin mortar. The mechanical properties of four series of mortars containing epoxy binder at 10, 15, 20, and 25 wt. % mixed with sand blended with sand washing waste filler in the range of 0–20 wt. % were examined. The compressive and flexural strength increased with the increase in epoxy and filler content; however, above epoxy 20 wt. %, slight change was seen in strength due to increase in epoxy and filler content. Modulus of elasticity also linearly increased with the increase in filler content, but the use of epoxy content beyond 20 wt. % decreased the modulus of elasticity of the mortar. For epoxy content at 10 wt. %, poor bond strength lower than 0.8 MPa was observed, and adding filler at 20 wt. % adversely affected the bond strength, in contrast to the mortars containing epoxy at 15, 20, 25 wt. %. The results indicate that the sand washing waste can be used as potential filler for epoxy resin mortar to obtain better mechanical properties by adding the optimum level of sand washing waste filler. PMID:28772603
Warren, L M; Halling-Brown, M D; Looney, P T; Dance, D R; Wallis, M G; Given-Wilson, R M; Wilkinson, L; McAvinchey, R; Young, K C
2017-09-01
To investigate the effect of image processing on cancer detection in mammography. An observer study was performed using 349 digital mammography images of women with normal breasts, calcification clusters, or soft-tissue lesions including 191 subtle cancers. Images underwent two types of processing: FlavourA (standard) and FlavourB (added enhancement). Six observers located features in the breast they suspected to be cancerous (4,188 observations). Data were analysed using jackknife alternative free-response receiver operating characteristic (JAFROC) analysis. Characteristics of the cancers detected with each image processing type were investigated. For calcifications, the JAFROC figure of merit (FOM) was equal to 0.86 for both types of image processing. For soft-tissue lesions, the JAFROC FOM were better for FlavourA (0.81) than FlavourB (0.78); this difference was significant (p=0.001). Using FlavourA a greater number of cancers of all grades and sizes were detected than with FlavourB. FlavourA improved soft-tissue lesion detection in denser breasts (p=0.04 when volumetric density was over 7.5%) CONCLUSIONS: The detection of malignant soft-tissue lesions (which were primarily invasive) was significantly better with FlavourA than FlavourB image processing. This is despite FlavourB having a higher contrast appearance often preferred by radiologists. It is important that clinical choice of image processing is based on objective measures. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Regulation of programmed cell death or apoptosis in atherosclerosis.
Geng, Y J
1997-01-01
Intimal thickening caused by accumulation of cells, lipids, and connective tissue characterizes atherosclerosis, an arterial disease that leads to cardiac and cerebral infarction. Apoptosis, or genetically programmed cell death, is important for the development and morphogenesis of organs and tissues. As in other tissues, cells of cardiovascular tissues can undergo apoptosis. Increased apoptosis has been found in both human and animal atherosclerotic lesions, mediating tissue turnover and lesion development. In addition to vascular cells, many activated immune cells, mainly macrophages and T cells, are present in atherosclerotic lesions, where these cells produce biologically active substances such as the proinflammatory cytokines tumor necrosis factor, interleukin-1 (IL-1), and interferon-gamma. Simultaneous exposure to these cytokines may trigger apoptosis of vascular smooth muscle cells. The products of death-regulating genes including Fas/Fas ligand, members of IL-1 beta cysteinyl protease (caspase) family, the tumor suppressive gene p53, and the protooncogene c-myc have been found in vascular cells and may participate in the regulation of vascular apoptosis during the development of atherosclerosis. Abnormal occurrence of apoptosis may take place in atherosclerotic lesions, including attenuation or acceleration of the apoptotic death process. The former may cause an increase in the cellularity of the lesions, and the latter can reduce cellular components important for maintaining the integrity and stability of the plaques. Clarification of the molecular mechanism that regulates apoptosis may help design a new strategy for treatment of patients with atherosclerosis and its major complications, heart attack and stroke.
Applications of biomaterials in plastic surgery.
Kim, Jeff J; Evans, Gregory R D
2012-10-01
The expansion of the application of biomaterials in plastic surgery has led to the increased availability of commercial products in recent years. This overview discusses soft tissue fillers, bioengineered skins, acellular dermal matrices, biomaterials for craniofacial surgery, and peripheral nerve repair. We summarize indications, properties, uses, types, advantages and disadvantages of some of the currently available products from each category. Finally, the current state of development in drug delivery system is also briefly summarized. Published by Elsevier Inc.
Jing, Xin; Mi, Hao-Yang; Turng, Lih-Sheng
2017-03-01
In this work, three-dimensional poly(caprolactone) (PCL) tissue engineering scaffolds were prepared by co-extrusion and gas foaming. Biocompatible hydroxyapatite (HA) and halloysite nanotubes (HNT) were added to the polymer matrix to enhance the mechanical properties and bioactivity of the composite scaffolds. The effects of HA and HNT on the rheological behavior, microstructure, and mechanical properties of the composite scaffolds were systematically compared. It was found that the HNT improved viscosity more significantly than HA, and reduced the pore size of scaffolds, while the mechanical performance of PCL/HNT scaffolds was higher than PCL/HA scaffolds with the same filler content. Human mesenchymal stem cells (hMSCs) were used as the cell model to compare the biological properties of two composite scaffolds. The results demonstrated that cells could survive on all scaffolds, and showed a more flourishing living state on the composite scaffolds. The cell differentiation for 5% HA and 1% HNT scaffolds were significantly higher than other scaffolds, while the differentiation of 5% HNT scaffolds was lower than that of 1% HNT scaffolds mainly because of the reduced pore size and pore interconnectivity. Therefore, this study suggested that, with proper filler content and control of microstructure through processing, HNT could be a suitable substitute for HA for bone tissue engineering to reduce the cost and improve mechanical performance. Copyright © 2016. Published by Elsevier B.V.
Automated geometric optimization for robotic HIFU treatment of liver tumors.
Williamson, Tom; Everitt, Scott; Chauhan, Sunita
2018-05-01
High intensity focused ultrasound (HIFU) represents a non-invasive method for the destruction of cancerous tissue within the body. Heating of targeted tissue by focused ultrasound transducers results in the creation of ellipsoidal lesions at the target site, the locations of which can have a significant impact on treatment outcomes. Towards this end, this work describes a method for the optimization of lesion positions within arbitrary tumors, with specific anatomical constraints. A force-based optimization framework was extended to the case of arbitrary tumor position and constrained orientation. Analysis of the approximate reachable treatment volume for the specific case of treatment of liver tumors was performed based on four transducer configurations and constraint conditions derived. Evaluation was completed utilizing simplified spherical and ellipsoidal tumor models and randomly generated tumor volumes. The total volume treated, lesion overlap and healthy tissue ablated was evaluated. Two evaluation scenarios were defined and optimized treatment plans assessed. The optimization framework resulted in improvements of up to 10% in tumor volume treated, and reductions of up to 20% in healthy tissue ablated as compared to the standard lesion rastering approach. Generation of optimized plans proved feasible for both sub- and intercostally located tumors. This work describes an optimized method for the planning of lesion positions during HIFU treatment of liver tumors. The approach allows the determination of optimal lesion locations and orientations, and can be applied to arbitrary tumor shapes and sizes. Copyright © 2018 Elsevier Ltd. All rights reserved.
Greaves, Erin; Cousins, Fiona L; Murray, Alison; Esnal-Zufiaurre, Arantza; Fassbender, Amelie; Horne, Andrew W; Saunders, Philippa T K
2014-07-01
Endometriosis is an estrogen-dependent inflammatory disorder characterized by the presence of endometrial tissue outside the uterine cavity. Patients experience chronic pelvic pain and infertility, with the most likely origin of the tissue deposits (lesions) being endometrial fragments shed at menses. Menstruation is an inflammatory process associated with a dramatic increase in inflammatory mediators and tissue-resident immune cells. In the present study, we developed and validated a mouse model of endometriosis using syngeneic menstrual endometrial tissue introduced into the peritoneum of immunocompetent mice. We demonstrate the establishment of endometriotic lesions that exhibit similarities to those recovered from patients undergoing laparoscopy. Specifically, in both cases, lesions had epithelial (cytokeratin(+)) and stromal (vimentin/CD10(+)) cell compartments with a well-developed vasculature (CD31(+) endothelial cells). Expression of estrogen receptor β was increased in lesions compared with the peritoneum or eutopic endometrium. By performing experiments using mice with green fluorescent protein-labeled macrophages (MacGreen) in reciprocal transfers with wild-type mice, we obtained evidence that macrophages present in the peritoneum and in menses endometrium can contribute to the inflammatory microenvironment of the lesions. In summary, we developed a mouse model of endometriosis that exhibits similarities to human peritoneal lesions with respect to estrogen receptor expression, inflammation, and macrophage infiltration, providing an opportunity for further studies and the possible identification of novel therapies for this perplexing disorder. Copyright © 2014 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Gross and Microscopic Lesions in Corals from Micronesia.
Work, T M; Aeby, G S; Hughen, K A
2016-01-01
The authors documented gross and microscopic morphology of lesions in corals on 7 islands spanning western, southern, and eastern Micronesia, sampling 76 colonies comprising 30 species of corals among 18 genera, with Acropora, Porites, and Montipora dominating. Tissue loss comprised the majority of gross lesions sampled (41%), followed by discoloration (30%) and growth anomaly (29%). Of 31 cases of tissue loss, most lesions were subacute (48%), followed by acute and chronic (26% each). Of 23 samples with discoloration, most were dark discoloration (40%), with bleaching and other discoloration each constituting 30%. Of 22 growth anomalies, umbonate growth anomalies composed half, with exophytic, nodular, and rugose growth anomalies composing the remainder. On histopathology, for 9 cases of dark discoloration, fungal infections predominated (77%); for 7 bleached corals, depletion of zooxanthellae from the gastrodermis made up a majority of microscopic diagnoses (57%); and for growth anomalies other than umbonate, hyperplasia of the basal body wall was the most common microscopic finding (63%). For the remainder of the gross lesions, no single microscopic finding constituted >50% of the total. Host response varied with the agent present on histology. Fragmentation of tissues was most often associated with algae (60%), whereas necrosis dominated (53%) for fungi. Two newly documented potentially symbiotic tissue-associated metazoans were seen in Porites and Montipora. Findings of multiple potential etiologies for a given gross lesion highlight the importance of incorporating histopathology in coral disease surveys. This study also expands the range of corals infected with cell-associated microbial aggregates. © The Author(s) 2015.
Gross and microscopic lesions in corals from Micronesia
Work, Thierry M.; Aeby, Greta S.; Hughen, Konrad A.
2015-01-01
The authors documented gross and microscopic morphology of lesions in corals on 7 islands spanning western, southern, and eastern Micronesia, sampling 76 colonies comprising 30 species of corals among 18 genera, with Acropora, Porites, and Montipora dominating. Tissue loss comprised the majority of gross lesions sampled (41%), followed by discoloration (30%) and growth anomaly (29%). Of 31 cases of tissue loss, most lesions were subacute (48%), followed by acute and chronic (26% each). Of 23 samples with discoloration, most were dark discoloration (40%), with bleaching and other discoloration each constituting 30%. Of 22 growth anomalies, umbonate growth anomalies composed half, with exophytic, nodular, and rugose growth anomalies composing the remainder. On histopathology, for 9 cases of dark discoloration, fungal infections predominated (77%); for 7 bleached corals, depletion of zooxanthellae from the gastrodermis made up a majority of microscopic diagnoses (57%); and for growth anomalies other than umbonate, hyperplasia of the basal body wall was the most common microscopic finding (63%). For the remainder of the gross lesions, no single microscopic finding constituted >50% of the total. Host response varied with the agent present on histology. Fragmentation of tissues was most often associated with algae (60%), whereas necrosis dominated (53%) for fungi. Two newly documented potentially symbiotic tissue-associated metazoans were seen in Porites and Montipora. Findings of multiple potential etiologies for a given gross lesion highlight the importance of incorporating histopathology in coral disease surveys. This study also expands the range of corals infected with cell-associated microbial aggregates.
NASA Astrophysics Data System (ADS)
Luo, Wenfeng; Zhang, Shuangying; Lan, Yuewei; Huang, Chen; Wang, Chao; Lai, Xuexu; Chen, Hanwei; Ao, Ningjian
2018-04-01
In this work, oyster shell powder (OSP) was used as the bio-filler and combined with polycaprolactone (PCL) through melt blending methodology. The PCL and PCL/OSP scaffolds were prepared using additive manufacturing process. All the 3D printed scaffolds hold a highly porosity and interconnected pore structures. OSP particles are dispersed in the polymer matrix, which helped to improve the degree of crystallinity and mineralization ability of the scaffolds. There was no significant cytotoxicity of the prepared scaffolds towards MG-63 cells, and all the scaffolds showed a well ALP activity. Therefore, PCL/OSP scaffolds had a high potential to be employed in the bone tissue engineering.
Production, characterization, and modeling of mineral filled polypropylene filaments
NASA Astrophysics Data System (ADS)
George, Brian Robert
1999-11-01
This research produced mineral filled polypropylene filaments using a variety of fillers, characterized these filaments, and attempted to model their mechanical properties with current composite models. Also, these filaments were compared with bone to determine if they are suitable for modeling the mechanical properties of bone. Fillers used consist of wollastonite, talc, calcium carbonate, titanium dioxide, and hydroxyapatite. Fillers and polypropylene chips were combined and extruded into rods with the use of a mixer. The rods were chipped up and then formed into filaments through melt extrusion utilizing a piston extruder. Filaments with volume fractions of filler of 0.05, 0.10, 0.15, and 0.20 were produced. Additionally, some methods of trying to improve the properties of these filaments were attempted, but did not result in any significant property improvements. The fillers and filaments were visually characterized with a scanning electron microscope. Cross-sections, filament outer surfaces, fracture surfaces, and longitudinal cut open surfaces were viewed in this manner. Those filaments with anisotropic filler had some oriented filler particles, while all filaments suffered from poor adhesion between the polypropylene and the filler as well as agglomerations of filler particles. Twenty specimens of each filament were tensile tested and the average tenacity, strain, and modulus were calculated. Filaments containing talc, talc and wollastonite, titanium dioxide, or hydroxyapatite suffered from a drastic transition from ductile to brittle with the addition of 0.05 volume fraction of filler. This is evidenced by the sharp decrease in strain at this volume fraction of filler when compared to the strain of the unfilled polypropylene filament. Additionally, these same filaments suffered a sharp decrease in tenacity at the same volume fraction. These instant decreases are attributed to the agglomerations of filler in the filament. Generally, the modulus of the filaments increased with the increase in concentration of filler. The tensile tenacity, strain, and modulus were modeled with current composite models for particulate filled composites. The tenacity and strain models did not accurately predict the properties of the filaments, while the modulus models were more accurate, perhaps because the agglomerations of filler did not affect the modulus as much as it affected the tenacity and strain of the filaments. Production, characterization, and modeling of these filaments indicates that there are many areas for improvements, such as improved mixing of the filler and polypropylene, increased adhesion between matrix and filler, and decreased agglomerations of filler. Mechanically, these filaments can not match the properties of bone. However, they do have many structural similarities at the micro-mechanical level, so with some improvements in properties these filaments may be suitable models for modeling bone behavior.
The Morel-Lavallée Lesion: Diagnosis and Management.
Scolaro, John A; Chao, Tom; Zamorano, David P
2016-10-01
The Morel-Lavallée lesion is a closed soft-tissue degloving injury commonly associated with high-energy trauma. The thigh, hip, and pelvic region are the most commonly affected locations. Timely identification and management of a Morel-Lavallée lesion is crucial because distracting injuries in the polytraumatized patient can result in a missed or delayed diagnosis. Bacterial colonization of these closed soft-tissue injuries has resulted in their association with high rates of perioperative infection. Recently, MRI has been used to characterize and classify these lesions. Definitive management is dictated by the size, location, and age of the injury and ranges from percutaneous drainage to open débridement and irrigation. Chronic lesions may lead to the development of pseudocysts and contour deformities of the extremity.
Fossey, Stacey; Vahle, John; Long, Philip; Schelling, Scott; Ernst, Heinrich; Boyce, Rogely Waite; Jolette, Jacquelin; Bolon, Brad; Bendele, Alison; Rinke, Matthias; Healy, Laura; High, Wanda; Roth, Daniel Robert; Boyle, Michael; Leininger, Joel
2016-01-01
The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions in Rats and Mice) Project (www.toxpath.org/inhand.asp) is an initiative of the Societies of Toxicological Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP) and North America (STP) to develop an internationally accepted nomenclature for proliferative and nonproliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature for classifying microscopic lesions observed in the skeletal tissues and teeth of laboratory rats and mice, with color photomicrographs illustrating examples of many common lesions. The standardized nomenclature presented in this document is also available on the internet (http://www.goreni.org/). Sources of material were databases from government, academic and industrial laboratories throughout the world. PMID:27621538
Dill, Alisa; Letra, Ariadne; Chaves de Souza, Letícia; Yadlapati, Mamatha; Biguetti, Claudia Cristina; Garlet, Gustavo Pompermaier; Vieira, Alexandre R; Silva, Renato Menezes
2015-02-01
It has been proposed that individual genetic predisposition may contribute to persistent apical periodontitis. Cytokines are associated with levels of inflammation and are involved in caries, pulpal, and periapical tissue destruction. We hypothesized that polymorphisms in cytokine genes may contribute to an individual's increased susceptibility to apical tissue destruction in response to deep carious lesions. Subjects with deep carious lesions with or without periapical lesions (≥3 mm) were recruited at the University of Pittsburgh, Pittsburgh, PA, and the University of Texas at Houston, Houston, TX. Genomic DNA samples of 316 patients were sorted into 2 groups: 136 cases with deep carious lesions and periapical lesions (cases) and 180 cases with deep carious lesions but no periapical lesions (controls). Nine single-nucleotide polymorphisms in IL1B, IL6, TNF, RANK, RANKL, and OPG genes were selected for genotyping. Genotypes were generated by end point analysis using TaqMan chemistry (Invitrogen, Carlsbad, CA) in a real-time polymerase chain reaction instrument. Allele and genotype frequencies were compared among cases and controls using the PLINK program (http://pngu.mgh.harvard.edu/purcell/plink/). Ninety-three human periapical granulomas and 24 healthy periodontal ligament tissues collected postoperatively were used for messenger RNA expression analyses of IL1B. A single-nucleotide polymorphism in IL1B (rs1143643) showed allelic (P = .02) and genotypic (P = .004) association with cases of deep caries and periapical lesions. We also observed altered transmission of IL1B marker haplotypes (P = .02) in these individuals. IL1B was highly expressed in granulomas (P < .001). Variations in IL1B may be associated with periapical lesion formation in individuals with untreated deep carious lesions. Future studies could help predict host susceptibility to developing periapical lesions. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Shao, Yue; Shi, Frank G.
2017-07-01
The effective passive radiation cooling that is enabled by silicone-based composites is investigated for its dependence on coating thickness and filler size in the range of nanometers to micrometers. It is established, contrary to prior reports, that the effective passive radiation cooling does not exhibit a filler size dependence, i.e., there is no optimal size at which a maximum cooling would be reached. However, the apparent cooling effect is filler type dependent and among the fillers investigated, Al2O3 exhibits the best apparent cooling effect. In addition, the apparent cooling effect is dependent on coating thickness: the thickness dependence is non-monotonic, and the maximum cooling occurs at an optimal thickness of 70 μm, regardless of filler type. Potential significant implications of the findings are also discussed.
The effect of elastic modulus on ablation catheter contact area.
Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R
2015-02-21
Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.
Wang, Enfeng; Wu, Yin; Cheung, Jerry S; Zhou, Iris Yuwen; Igarashi, Takahiro; Zhang, XiaoAn; Sun, Phillip Zhe
2017-10-01
Diffusion weighted imaging (DWI) has been commonly used in acute stroke examination, yet a portion of DWI lesion may be salvageable. Recently, it has been shown that diffusion kurtosis imaging (DKI) defines the most severely damaged DWI lesion that does not renormalize following early reperfusion. We postulated that the diffusion and kurtosis lesion mismatch experience heterogeneous hemodynamic and/or metabolic injury. We investigated tissue perfusion, pH, diffusion, kurtosis and relaxation from regions of the contralateral normal area, diffusion lesion, kurtosis lesion and their mismatch in an animal model of acute stroke. Our study revealed significant kurtosis and diffusion lesion volume mismatch (19.7 ± 10.7%, P < 0.01). Although there was no significant difference in perfusion and diffusion between the kurtosis lesion and kurtosis/diffusion lesion mismatch, we showed lower pH in the kurtosis lesion (pH = 6.64 ± 0.12) from that of the kurtosis/diffusion lesion mismatch (6.84 ± 0.11, P < 0.05). Moreover, pH in the kurtosis lesion and kurtosis/diffusion mismatch agreed well with literature values for regions of ischemic core and penumbra, respectively. Our work documented initial evidence that DKI may reveal the heterogeneous metabolic derangement within the commonly used DWI lesion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thanan, Raynoo; Department of Environmental and Molecular Medicine, Mie University Graduate School of Medicine, Tsu, Mie 514-8507; Ma, Ning
2012-05-04
Highlights: Black-Right-Pointing-Pointer Inflammation by Barrett's esophagus (BE) is a risk factor of its adenocarcinoma (BEA). Black-Right-Pointing-Pointer 8-Nitroguanine and 8-oxodG are inflammation-related DNA lesions. Black-Right-Pointing-Pointer DNA lesions and iNOS expression were higher in the order, BEA > BE > normal tissues. Black-Right-Pointing-Pointer Proton pump inhibitors suppress DNA damage by increasing Mn-SOD via Nrf2 activation. Black-Right-Pointing-Pointer DNA lesions can be useful biomarkers to predict risk of BEA in BE patients. -- Abstract: Barrett's esophagus (BE), an inflammatory disease, is a risk factor for Barrett's esophageal adenocarcinoma (BEA). Treatment of BE patients with proton pump inhibitors (PPIs) is expected to reduce the riskmore » of BEA. We performed an immunohistochemical study to examine the formation of nitrative and oxidative DNA lesions, 8-nitroguanine and 8-oxo-7,8-dihydro-2 Prime -deoxygaunosine (8-oxodG), in normal esophageal, BE with pre- and post-treatment by PPIs and BEA tissues. We also observed the expression of an oxidant-generating enzyme (iNOS) and its transcription factor NF-{kappa}B, an antioxidant enzyme (Mn-SOD), its transcription factor (Nrf2) and an Nrf2 inhibitor (Keap1). The immunoreactivity of DNA lesions was significantly higher in the order of BEA > BE > normal tissues. iNOS expression was significantly higher in the order of BEA > BE > normal tissues, while Mn-SOD expression was significantly lower in the order of BEA < BE < normal tissues. Interestingly, Mn-SOD expression and the nuclear localization of Nrf2 were significantly increased, and the formation of DNA lesions was significantly decreased in BE tissues after PPIs treatment for 3-6 months. Keap1 and iNOS expression was not significantly changed by the PPIs treatment in BE tissues. These results indicate that 8-nitroguanine and 8-oxodG play a role in BE-derived BEA. Additionally, PPIs treatment may trigger the activation and nuclear translocation of Nrf2 resulting in the expression of antioxidant genes, leading to DNA damage suppression. These DNA lesions can be useful biomarkers to predict both the risk of BEA and the efficacy of PPIs treatment to prevent BEA in BE patients.« less
High-frequency ultrasound M-mode monitoring of HIFU ablation in cardiac tissue
NASA Astrophysics Data System (ADS)
Kumon, R. E.; Gudur, M. S. R.; Zhou, Y.; Deng, C. X.
2012-10-01
Effective real-time HIFU lesion detection is important for expanded use of HIFU in interventional electrophysiology (e.g., epicardial ablation of cardiac arrhythmia). The goal of this study was to investigate rapid, high-frequency M-mode ultrasound imaging for monitoring spatiotemporal changes in tissue during HIFU application. The HIFU application (4.33 MHz, 1000 Hz PRF, 50% duty cycle, 1 s exposure, 6100 W/cm2) was perpendicularly applied to porcine cardiac tissue with a high-frequency imaging system (Visualsonics Vevo 770, 55 MHz, 4.5 mm focal distance) confocally aligned. Radiofrequency (RF) M-mode data (1 kHz PRF, 4 s × 7 mm) was acquired before, during, and after HIFU treatment. Gross lesions were compared with M-mode data to correlate lesion and cavity formation. Integrated backscatter, echo-decorrelation parameters, and their cumulative extrema over time were analyzed for automatically identifying lesion width and bubble formation. Cumulative maximum integrated backscatter showed the best results for identifying the final lesion width, and a criterion based on line-to-line decorrelation was proposed for identification of transient bubble activity.
Elastic and Sorption Characteristics of an Epoxy Binder in a Composite During Its Moistening
NASA Astrophysics Data System (ADS)
Aniskevich, K.; Glaskova, T.; Jansons, J.
2005-07-01
Results of an experimental investigation into the elastic and sorption characteristics of a model composite material (CM) — epoxy resin filled with LiF crystals — during its moistening are presented. Properties of the binder in the CM with different filler contents ( v f = 0, 0.05, 0.11, 0.23, 0.28, 0.33, 0.38, and 0.46) were evaluated indirectly by using known micromechanical models of CMs. It was revealed that, for the CM in a conditionally initial state, the elastic modulus of the binder in it and the filler microstrain (change in the interplanar distance in the crystals, measured by the X-ray method) as functions of filler content had the same character. The elastic modulus of the binder in the CM with a low filler content was equal to that for the binder in a block; the elastic modulus of the binder in the CM decreased with increasing filler content. The maximum (corresponding to water saturation of the CM) stresses in the binder and the filler microstresses as functions of filler content were of the same character. Moreover, the absolute values of maximum stresses in the binder and of filler microstresses coincided for high and low contents of the filler. At v f = 0.2-0. 3, the filler microstrains exceeded the stresses in the binder. The effect of moisture on the epoxy binder in the CM with a high filler content was not entirely reversible: the elastic characteristics of the binder increased, the diffusivity decreased, and the ultimate water content increased after a moistening-drying cycle.
Bezrukov, Ilja; Schmidt, Holger; Mantlik, Frédéric; Schwenzer, Nina; Brendle, Cornelia; Schölkopf, Bernhard; Pichler, Bernd J
2013-10-01
Hybrid PET/MR systems have recently entered clinical practice. Thus, the accuracy of MR-based attenuation correction in simultaneously acquired data can now be investigated. We assessed the accuracy of 4 methods of MR-based attenuation correction in lesions within soft tissue, bone, and MR susceptibility artifacts: 2 segmentation-based methods (SEG1, provided by the manufacturer, and SEG2, a method with atlas-based susceptibility artifact correction); an atlas- and pattern recognition-based method (AT&PR), which also used artifact correction; and a new method combining AT&PR and SEG2 (SEG2wBONE). Attenuation maps were calculated for the PET/MR datasets of 10 patients acquired on a whole-body PET/MR system, allowing for simultaneous acquisition of PET and MR data. Eighty percent iso-contour volumes of interest were placed on lesions in soft tissue (n = 21), in bone (n = 20), near bone (n = 19), and within or near MR susceptibility artifacts (n = 9). Relative mean volume-of-interest differences were calculated with CT-based attenuation correction as a reference. For soft-tissue lesions, none of the methods revealed a significant difference in PET standardized uptake value relative to CT-based attenuation correction (SEG1, -2.6% ± 5.8%; SEG2, -1.6% ± 4.9%; AT&PR, -4.7% ± 6.5%; SEG2wBONE, 0.2% ± 5.3%). For bone lesions, underestimation of PET standardized uptake values was found for all methods, with minimized error for the atlas-based approaches (SEG1, -16.1% ± 9.7%; SEG2, -11.0% ± 6.7%; AT&PR, -6.6% ± 5.0%; SEG2wBONE, -4.7% ± 4.4%). For lesions near bone, underestimations of lower magnitude were observed (SEG1, -12.0% ± 7.4%; SEG2, -9.2% ± 6.5%; AT&PR, -4.6% ± 7.8%; SEG2wBONE, -4.2% ± 6.2%). For lesions affected by MR susceptibility artifacts, quantification errors could be reduced using the atlas-based artifact correction (SEG1, -54.0% ± 38.4%; SEG2, -15.0% ± 12.2%; AT&PR, -4.1% ± 11.2%; SEG2wBONE, 0.6% ± 11.1%). For soft-tissue lesions, none of the evaluated methods showed statistically significant errors. For bone lesions, significant underestimations of -16% and -11% occurred for methods in which bone tissue was ignored (SEG1 and SEG2). In the present attenuation correction schemes, uncorrected MR susceptibility artifacts typically result in reduced attenuation values, potentially leading to highly reduced PET standardized uptake values, rendering lesions indistinguishable from background. While AT&PR and SEG2wBONE show accurate results in both soft tissue and bone, SEG2wBONE uses a two-step approach for tissue classification, which increases the robustness of prediction and can be applied retrospectively if more precision in bone areas is needed.
NASA Astrophysics Data System (ADS)
Avanaki, Ali R. N.; Espig, Kathryn; Knippel, Eddie; Kimpe, Tom R. L.; Xthona, Albert; Maidment, Andrew D. A.
2016-03-01
In this paper, we specify a notion of background tissue complexity (BTC) as perceived by a human observer that is suited for use with model observers. This notion of BTC is a function of image location and lesion shape and size. We propose four unsupervised BTC estimators based on: (i) perceived pre- and post-lesion similarity of images, (ii) lesion border analysis (LBA; conspicuous lesion should be brighter than its surround), (iii) tissue anomaly detection, and (iv) mammogram density measurement. The latter two are existing methods we adapt for location- and lesion-dependent BTC estimation. To validate the BTC estimators, we ask human observers to measure BTC as the visibility threshold amplitude of an inserted lesion at specified locations in a mammogram. Both human-measured and computationally estimated BTC varied with lesion shape (from circular to oval), size (from small circular to larger circular), and location (different points across a mammogram). BTCs measured by different human observers are correlated (ρ=0.67). BTC estimators are highly correlated to each other (0.84
Practical use of imaging technique for management of bone and soft tissue tumors.
Miwa, Shinji; Otsuka, Takanobu
2017-05-01
Imaging modalities including radiography, computed tomography (CT), and magnetic resonance imaging (MRI) are necessary for the diagnosis of bone and soft tissue tumors. The history of imaging began with the discovery of X-rays in the 19th century. The development of CT, MRI, ultrasonography, and positron emission tomography (PET) have improved the management of bone and soft tissue tumors. X-ray imaging and CT scans enable the evaluation of bone destruction, periosteal reaction, sclerotic changes in lesions, condition of cortical bone, and ossification. MRI enables the assessment of tissue characteristics, tumor extent, and the reactive areas. Functional imaging modalities including 201 thallium ( 201 Tl) scintigraphy can be used to differentiate benign lesions from malignant lesions and to assess chemotherapeutic effects. Real-time assessment of soft tissue tumors by ultrasonography enables accurate and safe performance of surgery and biopsy. This article describes useful imaging modalities and characteristic findings in the management of bone and soft tissue tumors. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Improved fiber retention by the use of fillers in graphite fiber/resin matrix composites
NASA Technical Reports Server (NTRS)
Gluyas, R. E.; Bowles, K. J.
1980-01-01
A variety of matrix fillers were tested for their ability to prevent loss of fiber from graphite fiber/PMR polyimide and graphite fiber/epoxy composites in a fire. The fillers tested included powders of boron, boron carbide lime glass, lead glass, and aluminum. Boron was the most effective and prevented any loss of graphite fiber during burning. Mechanical properties of composites containing boron filler were measured and compared to those of composites containing no filler.
Maccarrone, Giuseppina; Nischwitz, Sandra; Deininger, Sören-Oliver; Hornung, Joachim; König, Fatima Barbara; Stadelmann, Christine; Turck, Christoph W; Weber, Frank
2017-03-15
Multiple sclerosis is a disease of the central nervous system characterized by recurrent inflammatory demyelinating lesions in the early disease stage. Lesion formation and mechanisms leading to lesion remyelination are not fully understood. Matrix Assisted Laser Desorption Ionisation Mass Spectrometry imaging (MALDI-IMS) is a technology which analyses proteins and peptides in tissue, preserves their spatial localization, and generates molecular maps within the tissue section. In a pilot study we employed MALDI imaging mass spectrometry to profile and identify peptides and proteins expressed in normal-appearing white matter, grey matter and multiple sclerosis brain lesions with different extents of remyelination. The unsupervised clustering analysis of the mass spectra generated images which reflected the tissue section morphology in luxol fast blue stain and in myelin basic protein immunohistochemistry. Lesions with low remyelination extent were defined by compounds with molecular weight smaller than 5300Da, while more completely remyelinated lesions showed compounds with molecular weights greater than 15,200Da. An in-depth analysis of the mass spectra enabled the detection of cortical lesions which were not seen by routine luxol fast blue histology. An ion mass, mainly distributed at the rim of multiple sclerosis lesions, was identified by liquid chromatography and tandem mass spectrometry as thymosin beta-4, a protein known to be involved in cell migration and in restorative processes. The ion mass of thymosin beta-4 was profiled by MALDI imaging mass spectrometry in brain slides of 12 multiple sclerosis patients and validated by immunohistochemical analysis. In summary, our results demonstrate the ability of the MALDI-IMS technology to map proteins within the brain parenchyma and multiple sclerosis lesions and to identify potential markers involved in multiple sclerosis pathogenesis and/or remyelination. Copyright © 2016 Elsevier B.V. All rights reserved.
Why does starvation make bones fat?
Devlin, Maureen J.
2011-01-01
Body fat, or adipose tissue, is a crucial energetic buffer against starvation in humans and other mammals, and reserves of white adipose tissue (WAT) rise and fall in parallel with food intake. Much less is known about the function of bone marrow adipose tissue (BMAT), which are fat cells found in bone marrow. BMAT mass actually increases during starvation, even as other fat depots are being mobilized for energy. Here I review the possible reasons for this poorly understood phenomenon. Is BMAT a passive filler that occupies spaces left by dying bone cells, a pathological consequence of suppressed bone formation, or potentially an adaptation for surviving starvation? To evaluate these possibilities, here I review what is known about the effects of starvation on the body, particularly the skeleton, and the mechanisms involved in storing and metabolizing BMAT during negative energy balance. PMID:21793093
Why does starvation make bones fat?
Devlin, Maureen J
2011-01-01
Body fat, or adipose tissue, is a crucial energetic buffer against starvation in humans and other mammals, and reserves of white adipose tissue (WAT) rise and fall in parallel with food intake. Much less is known about the function of bone marrow adipose tissue (BMAT), which are fat cells found in bone marrow. BMAT mass actually increases during starvation, even as other fat depots are being mobilized for energy. This review considers several possible reasons for this poorly understood phenomenon. Is BMAT a passive filler that occupies spaces left by dying bone cells, a pathological consequence of suppressed bone formation, or potentially an adaptation for surviving starvation? These possibilities are evaluated in terms of the effects of starvation on the body, particularly the skeleton, and the mechanisms involved in storing and metabolizing BMAT during negative energy balance. Copyright © 2011 Wiley-Liss, Inc.
Zhang, Haipeng; Fu, Tong; Zhang, Zhiru; Fan, Zhimin; Zheng, Chao; Han, Bing
2014-08-01
To explore the value of application of support vector machine-recursive feature elimination (SVM-RFE) method in Raman spectroscopy for differential diagnosis of benign and malignant breast diseases. Fresh breast tissue samples of 168 patients (all female; ages 22-75) were obtained by routine surgical resection from May 2011 to May 2012 at the Department of Breast Surgery, the First Hospital of Jilin University. Among them, there were 51 normal tissues, 66 benign and 51 malignant breast lesions. All the specimens were assessed by Raman spectroscopy, and the SVM-RFE algorithm was used to process the data and build the mathematical model. Mahalanobis distance and spectral residuals were used as discriminating criteria to evaluate this data-processing method. 1 800 Raman spectra were acquired from the fresh samples of human breast tissues. Based on spectral profiles, the presence of 1 078, 1 267, 1 301, 1 437, 1 653, and 1 743 cm(-1) peaks were identified in the normal tissues; and 1 281, 1 341, 1 381, 1 417, 1 465, 1 530, and 1 637 cm(-1) peaks were found in the benign and malignant tissues. The main characteristic peaks differentiating benign and malignant lesions were 1 340 and 1 480 cm(-1). The accuracy of SVM-RFE in discriminating normal and malignant lesions was 100.0%, while that in the assessment of benign lesions was 93.0%. There are distinct differences among the Raman spectra of normal, benign and malignant breast tissues, and SVM-RFE method can be used to build differentiation model of breast lesions.
Detection of FUS induced lesions by MR-elastography
NASA Astrophysics Data System (ADS)
Jenne, Jürgen W.; Divkovic, Gabriela; Siegler, Peter
2005-03-01
MRI (Magnetic Resonance Imaging) has proven to be an exact and safe method to guide FUS (Focused ultrasound surgery) therapy. Besides its excellent soft tissue contrast, important for a precise treatment planning, MRI allows fast and reliable measurement of temperature changes caused by FUS application. In this study we compare standard MR-imaging parameters (relaxation times, spin density) with MR measured tissue elasticity in order to differentiate between FUS induced thermal lesions and normal tissue in vitro. In addition we tried to observe FUS induced shear waves by dynamic MRE. FUS was performed with an MRI compatible 1.7 MHz fixed focus transducer (NA 0.44; f'= 68 mm). With increasing acoustic power (30-70 W) the difference in relaxation times T1, T2 and spin density between normal and lesioned tissue also increased. We measured values in the range 5% to 24%. The difference in tissue strain had a value of 23% at 30 W and was nearly constant (52-61%) at higher FUS power. Compared with standard MRI parameters MRE showed a clearly higher sensitivity to detect FUS induced lesions. With our experimental setup it was possible to image FUS induced shear waves. The measured wave length at 400Hz repetition rate was 7 mm. However, further experiments are necessary to utilize the potential of MRE in practice.
Diagnostic criteria for selenium toxicosis in aquatic birds: histologic lesions
Green, D.E.; Albers, P.H.
1997-01-01
Chronic selenium toxicosis was induced in 1-year-old male mallard ducks (Anas platyrhynchos) by feeding selenium, as seleno-DL-methionine, in amounts of 0, 10, 20, 40, and 80 parts per million (ppm) to five groups of 21 ducks each for 16 wk during March to July 1988. All mallards in the 80 ppm group, three in the 40 ppm group, and one in the 20 ppm group died. Histologic lesions in mallards that died of selenosis were hepatocellular vacuolar degeneration progressing to centrolobular and panlobular necrosis, nephrosis, apoptosis of pancreatic exocrine cells, hypermaturity and avascularity of contour feathers of the head with atrophy of feather follicles, lymphocytic necrosis and atrophy of lymphoid organs (spleen, gut-associated lymphoid tissue, and lumbar lymph nodes), and severe atrophy and degeneration of fat. Histologic lesions in surviving mallards in the 40 ppm group, which had tissue residues of selenium comparable to mallards that died, were fewer and much milder than mallards that died; lesions consisted of atrophy of lymphoid tissue, hyalinogranular swelling of hepatocytes, atrophy of seminiferous tubules, and senescence of feathers. No significant histologic lesions were detected in euthanized mallards in the 0, 10 and 20 ppm groups. Based on tissue residues and histologic findings, primarily in the liver, there was a threshold of selenium accumulation above which pathophysiologic changes were rapid and fatal. Pathognomonic histologic lesions of fatal and nonfatal selenosis were not detected. Criteria for diagnosis of fatal selenosis in aquatic birds include consistent histologic lesions in the liver, kidneys, and organs of the immune system. Although histologic changes were present in cases of chronic non-fatal selenosis, these were inconsistent. Consistent features of fatal and non-fatal chronic selenosis were marked weight loss and elevated concentrations of selenium in organs.
Lee, Chang-Hyung; Derby, Richard; Choi, Hyun-Seok; Lee, Sang-Heon; Kim, Se Hoon; Kang, Yoon Kyu
2010-01-01
One technique in radiofrequency neurotomies uses 2 electrodes that are simultaneously placed to lie parallel to one another. Comparing lesions on cadaveric interspinous ligament tissue and measuring the temperature change in egg white allows us to accurately measure quantitatively the area of the lesion. Fresh cadaver spinal tissue and egg white tissue were used. A series of samples were prepared with the electrodes placed 1 to 7 mm apart. Using radiofrequency, the needle electrodes were heated in sequential or simultaneous order and the distance of the escaped lesion area and temperature were measured. Samples of cadaver interspinous ligament showed sequential heating of the needles limits the placement of the needle electrodes up to 2 mm apart from each other and up to 4 mm apart when heated simultaneously. The temperature at the escaped lesion area decreased according to the distance for egg white. There was a significant difference in temperature at the escaped lesion area up to 6 mm apart and the temperature was above 50 degrees celsius up to 5 mm in simultaneous lesion and 3 mm in the sequential lesion. The limitations of this study include cadaveric experimentation and use of intraspinous ligament rather than medial branch of the dorsal ramus which is difficult to identify. Heating the 2 electrodes simultaneously appears to coagulate a wider area and potentially produce better results in less time.
Morel-Lavallee Lesion (MLL) Mimicking A Soft Tissue Neoplasm.
Kumar, Sandeep; Hasan, Roumina; Kadavigere, Rajagopal; Maddukuri, Satish Babu; Puppala, Radha
2015-04-01
Morel-lavallee lesion (MLL) represents post traumatic subcutaneous cyst generally overlying bony prominences like greater trochanter, lower back, knee and scapula. A 51-year-old man presented with a swelling in left thigh since six years which was insidious in onset, gradually progressive in size and not associated with pain, fever or discharge. There was no history of trauma or any associated constitutional symptoms. Since there was no history of trauma recalled by the patient the clinical dilemma was between soft tissue sarcoma and cold abscess. We report a case of slow growing painless mass lesion of thigh, diagnosed on Magnetic Resonance Imaging (MRI) as morel lavallee lesion and describe its salient imaging features with treatment options.
Visualization of suspicious lesions in breast MRI based on intelligent neural systems
NASA Astrophysics Data System (ADS)
Twellmann, Thorsten; Lange, Oliver; Nattkemper, Tim Wilhelm; Meyer-Bäse, Anke
2006-05-01
Intelligent medical systems based on supervised and unsupervised artificial neural networks are applied to the automatic visualization and classification of suspicious lesions in breast MRI. These systems represent an important component of future sophisticated computer-aided diagnosis systems and enable the extraction of spatial and temporal features of dynamic MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogenity of the cancerous tissue, these techniques reveal the malignant, benign and normal kinetic signals and and provide a regional subclassification of pathological breast tissue. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging.
Singh, Deepa; Chopra, Aditi; Ravina, Mudalsha; Kongara, Srikant; Bhatia, Eesh; Kumar, Narvesh; Gupta, Sushil; Yadav, Subhash; Dabadghao, Preeti; Yadav, Rajnikant; Dube, Veeresh; Kumar, Utham; Dixit, Manish; Gambhir, Sanjay
2017-04-01
The aim of this study was to evaluate the role of 68 Ga-DOTANOC positron emission tomography (PET)/CT scan in localization of culprit lesion for biopsy and required intervention [surgical excision/radiofrequency ablation (RFA)] in patients with long-standing oncogenic osteomalacia (OOM)/tumour-induced osteomalacia. 17 patients (8 males and 9 females) underwent 68 Ga-DOTANOC PET/CT scan. The patients referred with clinical and biochemical evidence of hypophosphatemia and raised fibroblast growth factor-23. Qualitative and semi-quantitative parameters were used to identify culprit lesions. 68 Ga-DOTANOC PET/CT scan revealed 52 lesions in 17 patients, and 37/52 of these lesions were tracer avid. 26/37 lesions were non-specific focal tracer-avid skeletal lesions (fractures or degenerative changes). 11/37 tracer-avid skeletal lesions present in 9 patients (3 lesions in 1 patient and 1 each in rest of the 8 patients) were highly suspicious for culprit lesions in view of high maximum standardized uptake value (SUV max ) (range 1.5-15.4; mean 7.0 ± 4.6), lesion size (0.9-5.0 cm; mean 3.3 ± 1.5) and associated soft-tissue component. During subsequent imaging with CT/MRI, 7/9 patients showed concordant lesions which were excised or biopsied and histopathologically verified as phosphaturic mesenchymal tumours. Surgical excision was resorted to in most of the detected lesions, and RFA was performed in one patient. There is some overlap in SUV max between fracture-/bone-associated lesions and culprit lesions with a tendency of most non-culprit lesions to have lower SUV max and no associated soft-tissue component. In such scenario, intensely tracer-avid, larger non-fracture lesions with soft-tissue component may lead to identification of culprit lesion among multiple lesions. Following detection of culprit lesion, surgical removal is the best treatment. RFA is alternative to surgery in cases where surgery is not possible owing to osteopenia/poor bone health. Advances in knowledge: The main challenge in patients of long-standing OOM is the presence of multiple skeletal lesions (both tumour- or tracer-avid fractures), and it is confusing to identify culprit lesion. This was noted in our study with 68 Ga-DOTANOC and has not been mentioned in studies performed with 68 Ga-DOTATATE/TOC PET/CT. In such scenario, 68 Ga-DOTANOC PET/CT needs to be reviewed and read thoroughly to localize the culprit lesion out of the multiple tracer-avid lesions.
STUDIES OF ARTHRITIS AND OTHER LESIONS INDUCED IN RATS BY INJECTION OF MYCOBACTERIAL ADJUVANT
Pearson, Carl M.; Waksman, Byron H.; Sharp, John T.
1961-01-01
A generalized disease is induced experimentally in the rat by administration of Freund's adjuvant. The primary clinical and pathologic lesions are arthritis, periarthritis, peritendinitis, and periostitis in the joints of the extremities and tail. Accompanying the arthritis in some cases, and never observed in its absence, are other specific tissue lesions including iridocyclitis, nodular lesions in the glabrous skin (ear, genitalia, feet, tail), transient rashes, a chronic skin disease, genitourinary lesions, and diarrhea. These make up a striking and characteristic picture. The arthritis usually precedes the other lesions and, together with the skin disease may show a prolonged and fluctuating course. Visceral lesions do not occur. Histologically, the basic lesion is a lymphocytic and histiocytic infiltration, initially perivascular and subsequently more disseminated. In addition, in the region of the joints and in the corpora cavernosa of the penis, there is extensive proliferation of mesenchymal cells, especially fibroblasts. Foci of fibrinoid necrosis are seen in the articular and nodular lesions, and destructive lesions of the joints are common. Such a combination of tissue lesions has not previously been described in experimental pathology. The experimental disease is shown to have both similarities to and differences from Reiter's syndrome, rheumatoid arthritis, and certain other disorders which occur in man. PMID:13733780
46 CFR 57.02-5 - Filler metals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Filler metals. 57.02-5 Section 57.02-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING General Requirements § 57.02-5 Filler metals. (a) Except as provided for in paragraph (b) of this section, when filler...
USDA-ARS?s Scientific Manuscript database
Reinforcement effect of cryogenically fractured soy Flour composite filler in soft polymer was investigated in this study. Polymer composites were prepared by melt-mixing polymer and soy flour composite fillers in an internal mixer. Soy flour composite fillers were prepared by blending aqueous dis...
46 CFR 57.02-5 - Filler metals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Filler metals. 57.02-5 Section 57.02-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING General Requirements § 57.02-5 Filler metals. (a) Except as provided for in paragraph (b) of this section, when filler...
46 CFR 57.02-5 - Filler metals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Filler metals. 57.02-5 Section 57.02-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING General Requirements § 57.02-5 Filler metals. (a) Except as provided for in paragraph (b) of this section, when filler...
46 CFR 57.02-5 - Filler metals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Filler metals. 57.02-5 Section 57.02-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING General Requirements § 57.02-5 Filler metals. (a) Except as provided for in paragraph (b) of this section, when filler...
46 CFR 57.02-5 - Filler metals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Filler metals. 57.02-5 Section 57.02-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING General Requirements § 57.02-5 Filler metals. (a) Except as provided for in paragraph (b) of this section, when filler...
Comparative study on thermodynamic characteristics of AgCuZnSn brazing alloys
NASA Astrophysics Data System (ADS)
Wang, Xingxing; Li, Shuai; Peng, Jin
2018-01-01
AgCuZnSn brazing alloys were prepared based on the BAg50CuZn filler metal through electroplating diffusion process, and melting alloying method. The thermodynamics of phase transformations of those fillers were analyzed by non-isothermal differentiation and integration methods of thermal analysis kinetics. In this study, it was demonstrated that as the Sn content increased, the reaction fractional integral curves of AgCuZnSn fillers from solid to liquid became straighter at the endothermic peak. Under the same Sn contents, the reaction fractional integral curve of the Sn-plated filler metal was straighter, and the phase transformation activation energy was higher compared to the traditional silver filler metal. At the 7.2 wt% Sn content, the activation energies and pre-exponential factors of the two fillers reached the maximum, then the phase transformation rate equations of the Sn-plated silver filler and the traditional filler were determined as: k = 1.41 × 1032exp(-5.56 × 105/RT), k = 7.29 × 1020exp(-3.64 × 105/RT), respectively.
NASA Astrophysics Data System (ADS)
Kim, Ji Mun; Han, Mi Sun; Kim, Youn Hee; Kim, Woo Nyon
2008-07-01
The polyurethane foams (PUFs) were prepared by polyether polyols, polymeric 4,4'-diphenylmethane diisocyanate (PMDI), silicone surfactants, amine catalysts and cyclopentane as a blowing agent. Solid and liquid type fillers were used as a nucleating agent to decrease a cell size of the PUFs as well as improve the thermal insulating properties of the PUFs. The PUFs were prepared by adding solid and liquid type fillers in the range of 1 to 3 wt%. For the liquid type fillers, the cell size of the PUFs showed minimum and found to decrease compared the PUF without adding fillers. Also, thermal conductivity of the PUFs with adding fillers showed minimum. For the solid type fillers, cell size and thermal conductivity of the PUFs were observed to decrease with the filler content up to 3 wt%. From these results, it is suggested that the thermal insulating property of the PUFs can be improved by adding fillers as a nucleating agent. Also, storage and loss modulus of the PUFs will be presented to study gelling points of the PUFs.
Jin, Xin; Deng, Mao; Kaps, Sören; Zhu, Xinwei; Hölken, Iris; Mess, Kristin; Adelung, Rainer; Mishra, Yogendra Kumar
2014-01-01
ZnO particles of different size and structures were used as fillers to modify the silicone rubber, in order to reveal the effect of the filler shape in the polymer composites. Tetrapodal shaped microparticles, short microfibers/whiskers, and nanosized spherical particles from ZnO have been used as fillers to fabricate the different ZnO-Silicone composites. The detailed microstructures of the fillers as well as synthesized composites using scanning electron microscopy have been presented here. The tensile elastic modulus and water contact angle, which are important parameters for bio-mimetic applications, of fabricated composites with different fillers have been measured and compared. Among all three types of fillers, tetrapodal shaped ZnO microparticles showed the best performance in terms of increase in hydrophobicity of material cross-section as well as the stiffness of the composites. It has been demonstrated that the tetrapodal shaped microparticles gain their advantage due to the special shape, which avoids agglomeration problems as in the case for nanoparticles, and the difficulty of achieving truly random distribution for whisker fillers. PMID:25208080
Jin, Xin; Deng, Mao; Kaps, Sören; Zhu, Xinwei; Hölken, Iris; Mess, Kristin; Adelung, Rainer; Mishra, Yogendra Kumar
2014-01-01
ZnO particles of different size and structures were used as fillers to modify the silicone rubber, in order to reveal the effect of the filler shape in the polymer composites. Tetrapodal shaped microparticles, short microfibers/whiskers, and nanosized spherical particles from ZnO have been used as fillers to fabricate the different ZnO-Silicone composites. The detailed microstructures of the fillers as well as synthesized composites using scanning electron microscopy have been presented here. The tensile elastic modulus and water contact angle, which are important parameters for bio-mimetic applications, of fabricated composites with different fillers have been measured and compared. Among all three types of fillers, tetrapodal shaped ZnO microparticles showed the best performance in terms of increase in hydrophobicity of material cross-section as well as the stiffness of the composites. It has been demonstrated that the tetrapodal shaped microparticles gain their advantage due to the special shape, which avoids agglomeration problems as in the case for nanoparticles, and the difficulty of achieving truly random distribution for whisker fillers.
Agminated Fibroblastic Conective Tissue Nevus: A New Clinical Presentation.
Downey, Camila; Requena, Luis; Bagué, Silvia; Sánchez Martínez, Miquel Ángel; Lloreta, Josep; Baselga, Eulalia
2016-07-01
Connective tissue nevi are benign hamartomatous lesions in which one or several of the components of the dermis (collagen, elastin, glicosaminoglycans) show predominance or depletion. Recently, de Feraudy et al broadened the spectrum of connective tissue nevus, describing fibroblastic connective tissue nevus (FCTN), which is characterized by proliferation of CD34(+) cells of fibroblastic and myofibroblastic lineage. Only solitary papules and nodules have been described. We present the first case of FCTN with multiple agminated lesions on the leg of an infant and the difficulties encountered in the differential diagnosis with dermatofibrosarcoma protuberans. © 2016 Wiley Periodicals, Inc.
Vibration anesthesia for the reduction of pain with facial dermal filler injections.
Mally, Pooja; Czyz, Craig N; Chan, Norman J; Wulc, Allan E
2014-04-01
Vibration anesthesia is an effective pain-reduction technique for facial cosmetic injections. The analgesic effect of this method was tested in this study during facial dermal filler injections. The study aimed to evaluate the safety and efficacy of vibration anesthesia for these facial injections. This prospective study analyzed 41 patients who received dermal filler injections to the nasolabial folds, tear troughs, cheeks, and other facial sites. The injections were administered in a randomly assigned split-face design. One side of the patient's face received vibration together with dermal filler injections, whereas the other side received dermal filler injections alone. The patients completed a posttreatment questionnaire pertaining to injection pain, adverse effects, and preference for vibration with future dermal filler injections. The patients experienced both clinically and statistically significant pain reduction when a vibration stimulus was co-administered with the dermal filler injections. No adverse events were reported. The majority of the patients (95 %) reported a preference for vibration anesthesia with subsequent dermal filler injections. Vibration is a safe and effective method of achieving anesthesia during facial dermal filler injections. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Organic filler from golden apple snails shells to improve the silicone rubber insulator properties
NASA Astrophysics Data System (ADS)
Tepsila, Sujirat; Suksri, Amnart
2018-02-01
This paper investigates the effect of an addition of filler compound using golden apple snail shell as an organic filler to the silicone rubber insulator. The filler obtained from golden apple snail shell is found mostly contained calcium carbonate. The organic calcium carbonate (CaCO3) with particle size of 45, 75, 100 and 300 micron were prepared. Sample of silicone rubber that were filled with fillers were tested under ASTM D638-02a type standard for mechanical test. Also, electrical test such as I-V characteristics (ASTM D257-07) and dry arc test according to ASTM D495-14 have been performed. The results revealed that using larger particle size of organic filler obtained from the golden apple snail shell resulted to higher value of dielectric constant as well as higher dielectric strength. Also, the filler helps slow down the tracking activity at an insulator surface due to its crystals of calcium carbonate. However, when using excessive amount of filler, the sample will have a drawbacks in mechanical properties. By using agriculture waste as a filler compound, one can reduced the usage of commercial CaCO3 as an inorganic materials and to lower the investment cost to a final silicone rubber product.
Are functional fillers improving environmental behavior of plastics? A review on LCA studies.
Civancik-Uslu, Didem; Ferrer, Laura; Puig, Rita; Fullana-I-Palmer, Pere
2018-06-01
The use of functional fillers can be advantageous in terms of cost reduction and improved properties in plastics. There are many types of fillers used in industry, organic and inorganic, with a wide application area. As a response to the growing concerns about environmental damage that plastics cause, recently fillers have started to be considered as a way to reduce it by decreasing the need for petrochemical resources. Life cycle assessment (LCA) is identified as a proper tool to evaluate potential environmental impacts of products or systems. Therefore, in this study, the literature regarding LCA of plastics with functional fillers was reviewed in order to see if the use of fillers in plastics could be environmentally helpful. It was interesting to find out that environmental impacts of functional fillers in plastics had not been studied too often, especially in the case of inorganic fillers. Therefore, a gap in the literature was identified for the future works. Results of the study showed that, although there were not many and some differences exist among the LCA studies, the use of fillers in plastics industry may help to reduce environmental emissions. In addition, how LCA methodology was applied to these materials was also investigated. Copyright © 2018 Elsevier B.V. All rights reserved.
Crosslinked hyaluronic acid dermal fillers: a comparison of rheological properties.
Falcone, Samuel J; Berg, Richard A
2008-10-01
Temporary dermal fillers composed of crosslinked hyaluronic acid (XLHA) are space filling gels that are readily available in the United States and Europe. Several families of dermal fillers based on XLHA are now available and here we compare the physical and rheological properties of these fillers to the clinical effectiveness. The XLHA fillers are prepared with different crosslinkers, using HA isolated from different sources, have different particle sizes, and differ substantially in rheological properties. For these fillers, the magnitude of the complex viscosity, |eta*|, varies by a factor of 20, the magnitude of the complex rigidity modulus, |G*|, and the magnitude of the complex compliance, |J*| vary by a factor of 10, the percent elasticity varies from 58% to 89.9%, and the tan delta varies from 0.11 to 0.70. The available clinical data cannot be correlated with either the oscillatory dynamic or steady flow rotational rheological properties of the various fillers. However, the clinical data appear to correlate strongly with the total concentration of XLHA in the products and to a lesser extent with percent elasticity. Hence, our data suggest the following correlation: dermal filler persistence = [polymer] x [% elasticity] and the clinical persistence of a dermal filler composed of XLHA is dominated by the mass and elasticity of the material implanted. This work predicts that the development of future XLHA dermal filler formulations should focus on increasing the polymer concentration and elasticity to improve the clinical persistence.
Effect of mechanical properties of fillers on the grindability of composite resin adhesives.
Iijima, Masahiro; Muguruma, Takeshi; Brantley, William A; Yuasa, Toshihiro; Uechi, Jun; Mizoguchi, Itaru
2010-10-01
The purpose of this study was to investigate the effect of filler properties on the grindability of composite resin adhesives. Six composite resin products were selected: Transbond XT (3M Unitek, Monrovia, Calif), Transbond Plus (3M Unitek), Enlight (Ormco, Glendora, Calif), Kurasper F (Kuraray Medical, Tokyo, Japan), Beauty Ortho Bond (Shofu, Kyoto, Japan), and Beauty Ortho Bond Salivatect (Shofu). Compositions and weight fractions of fillers were determined by x-ray fluorescence analysis and ash test, respectively. The polished surface of each resin specimen was examined with a scanning electron microscope. Vickers hardness of plate specimens (15 × 10 × 3 mm) was measured, and nano-indentation was performed on large filler particles (>10 μm). Grindability for a low-speed tungsten-carbide bur was estimated. Data were compared with anlaysis of variance (ANOVA) and the Tukey multiple range test. Relationships among grindability, filler content, filler nano-indentation hardness (nano-hardness), filler elastic modulus, and Vickers hardness of the composite resins were investigated with the Pearson correlation coefficient test. Morphology and filler size of these adhesives showed great variations. The products could be divided into 2 groups, based on composition, which affected grindability. Vickers hardness of the adhesives did not correlate (r = 0.140) with filler nano-hardness, which showed a significant negative correlation (r = -0.664) with grindability. Filler nano-hardness greatly influences the grindability of composite resin adhesives. Copyright © 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Suspect filler similarity in eyewitness lineups: a literature review and a novel methodology.
Fitzgerald, Ryan J; Oriet, Chris; Price, Heather L
2015-02-01
Eyewitness lineups typically contain a suspect (guilty or innocent) and fillers (known innocents). The degree to which fillers should resemble the suspect is a complex issue that has yet to be resolved. Previously, researchers have voiced concern that eyewitnesses would be unable to identify their target from a lineup containing highly similar fillers; however, our literature review suggests highly similar fillers have only rarely been shown to have this effect. To further examine the effect of highly similar fillers on lineup responses, we used morphing software to create fillers of moderately high and very high similarity to the suspect. When the culprit was in the lineup, a higher correct identification rate was observed in moderately high similarity lineups than in very high similarity lineups. When the culprit was absent, similarity did not yield a significant effect on innocent suspect misidentification rates. However, the correct rejection rate in the moderately high similarity lineup was 20% higher than in the very high similarity lineup. When choosing rates were controlled by calculating identification probabilities for only those who made a selection from the lineup, culprit identification rates as well as innocent suspect misidentification rates were significantly higher in the moderately high similarity lineup than in the very high similarity lineup. Thus, very high similarity fillers yielded costs and benefits. Although our research suggests that selecting the most similar fillers available may adversely affect correct identification rates, we recommend additional research using fillers obtained from police databases to corroborate our findings.
Fine-needle aspiration cytology of hemangiopericytoma: A report of five cases.
Chhieng, D; Cohen, J M; Waisman, J; Fernandez, G; Cangiarella, J
1999-08-25
Hemangiopericytoma (HPC) is a relatively rare neoplasm, accounting for approximately 2.5% of all soft tissue tumors. Its histopathology has been well documented but to the authors' knowledge reports regarding its fine-needle aspiration (FNA) cytology rarely are encountered. In the current study the authors report the cytologic findings in FNA specimens from nine confirmed cases of HPC and attempt to correlate the cytologic features with the biologic outcomes. FNA was performed with or without radiologic guidance. Corresponding sections of tissue were reviewed in conjunction with the cytologic preparations. Nine FNAs were performed in 5 patients (3 men and 2 women) with an age range of 38-77 years (mean, 56 years). Two lesions were primary soft tissue lesions arising in the lower extremities; seven were recurrent or metastatic lesions from bone (one lesion), kidney (one lesion), pelvic fossa (one lesion), lower extremities (two lesions), trunk (one lesion), and breast (one lesion). All aspirates were cellular and were comprised of single and tightly packed clusters of oval to spindle-shaped cells aggregated around branched capillaries. Basement membrane material was observed in 6 cases (67%). The nuclei were uniform and oval, with finely granular chromatin and inconspicuous nucleoli in all cases except one. No mitotic figures or areas of necrosis were identified. A correct diagnosis of HPC was made on one primary lesion and all recurrent or metastatic lesions. HPCs show a spindle cell pattern in cytologic preparations and must be distinguished from more common spindle cell lesions. The presence of branched capillaries and abundant basement membrane material supports a diagnosis of HPC. Immunohistochemistry and electron microscopy performed on FNA samples may be helpful in the differential diagnosis. FNA is a useful and accurate tool with which to confirm recurrent or metastatic HPC; however, prediction of the biologic behavior of HPC based on cytologic features is not feasible. Cancer (Cancer Cytopathol) Copyright 1999 American Cancer Society.
NASA Astrophysics Data System (ADS)
Techavipoo, Udomchai
Manual palpation to sense variations in tissue stiffness for disease diagnosis has been regularly performed by clinicians for centuries. However, it is generally limited to large and superficial structures and the ability of the physician performing the palpation. Imaging of tissue stiffness or elastic properties via the aid of modern imaging such as ultrasound and magnetic resonance imaging, referred to as elastography, enhances the capability for disease diagnosis. In addition, elastography could be used for monitoring tissue response to minimally invasive ablative therapies, which are performed percutaneously to destruct tumors with minimum damage to surrounding tissue. Monitoring tissue temperature during ablation is another approach to estimate tissue damage. The ultimate goal of this dissertation is to improve the image quality of elastograms and temperature profiles for visualizing thermal lesions during and after ablative therapies. Elastographic imaging of thermal lesions is evaluated by comparison of sizes, shapes, and volumes with the results obtained using gross pathology. Semiautomated segmentation of lesion boundaries on elastograms is also developed. It provides comparable results to those with manual segmentation. Elastograms imaged during radiofrequency ablation in vitro show that the impact of gas bubbles during ablation on the ability to delineate the thermal lesion is small. Two novel methods to reduce noise artifacts in elastograms, and an accurate estimation of displacement vectors are proposed. The first method applies wavelet-denoising algorithms to the displacement estimates. The second method utilizes angular compounding of the elastograms generated using ultrasound signal frames acquired from different insonification angles. These angular frames are also utilized to estimate all tissue displacement vector components in response to a deformation. These enable the generation of normal and shear strain elastograms and Poisson's ratio elastograms, which provide additional valuable information for disease diagnosis. Finally, measurements of temperature dependent variables, including sound speed, attenuation coefficient, and thermal expansion in canine liver tissue, are performed. This information is necessary for the estimation of the temperature profile during ablation. A mapping function between the gradient of timeshifts and tissue temperature is calculated using this information and subsequently applied to estimate temperature profiles.
Okamoto, Takeshi; Matsuda, Shuichi
2017-01-01
Chronic expanding hematoma is characterized by continuous growth of a blood collection. We analyzed the clinical features of 7 patients with chronic expanding hematomas in the extremities, with an average age of 65.6 years. All lesions occurred in the lower extremities, with 4 seen in the thigh and 3 in the knee region. Six patients had subcutaneous hematomas, while 1 was deep-seated in the thigh. The magnetic resonance features of the lesion were compatible with those of a standard hematoma. A low signal intensity on T1- and T2-weighted imaging at the pseudocapsule was also characteristic. Cystic features were seen in 5 of 7 patients. All lesions were resected together with their pseudocapsule. In the subcutaneous lesions, it was necessary to resect adherent fascia, with or without involved skin. In the deep-seated thigh lesion, the common peroneal nerve was completely adherent to the pseudocapsule, a phenomenon from absence of the common peroneal nerve which appeared after resection. Chronic expanding hematomas of the extremities are predominantly located in the subcutaneous tissue of the lower extremity. The surrounding pseudocapsule is adherent to the adjacent tissues, and clinicians must be aware of this, especially when resecting a deep-seated lesion. PMID:28642872
NASA Astrophysics Data System (ADS)
Wu, T. Y.; Lin, S. F.
2013-10-01
Automatic suspected lesion extraction is an important application in computer-aided diagnosis (CAD). In this paper, we propose a method to automatically extract the suspected parotid regions for clinical evaluation in head and neck CT images. The suspected lesion tissues in low contrast tissue regions can be localized with feature-based segmentation (FBS) based on local texture features, and can be delineated with accuracy by modified active contour models (ACM). At first, stationary wavelet transform (SWT) is introduced. The derived wavelet coefficients are applied to derive the local features for FBS, and to generate enhanced energy maps for ACM computation. Geometric shape features (GSFs) are proposed to analyze each soft tissue region segmented by FBS; the regions with higher similarity GSFs with the lesions are extracted and the information is also applied as the initial conditions for fine delineation computation. Consequently, the suspected lesions can be automatically localized and accurately delineated for aiding clinical diagnosis. The performance of the proposed method is evaluated by comparing with the results outlined by clinical experts. The experiments on 20 pathological CT data sets show that the true-positive (TP) rate on recognizing parotid lesions is about 94%, and the dimension accuracy of delineation results can also approach over 93%.
Carrillo, Celia; Penarrocha, Miguel; Ortega, Bárbara; Martí, Eva; Bagán, José Vicente; Vera, Francisco
2008-08-01
This study was conducted to relate the histological diagnosis of chronic inflammatory periapical lesions with the radiographic images of these lesions. A total of 70 biopsy specimens obtained during periapical surgery were stained with hematoxylin and eosin and examined under a microscope. Histological analysis established the diagnosis as granuloma, cyst, or scar tissue. The location of the lesion was recorded, as were the radiographic size (maximum and minimum diameter in mm and area in mm(2)) and the presence of radiopaque lamina around the lesion, using an image analyzing system. The distribution of the biopsy specimens was 65.7% granulomas, 25.7% scar tissue, and 8.6% cysts, 1 of which was a keratocyst. The largest lesions were cysts and epithelialized granulomas, with statistically significant differences. Radiopaque lamina was observed around 9 lesions; of these, only 2 were histologically diagnosed as cysts, with the rest as granulomas. Most of the apical lesions were granulomas. Cysts had the largest radiotransparent images; however, in the 70 cases studied, neither the radiographic size nor the presence of associated radiopaque lamina alone was sufficient to determine the type of lesion. Histological analysis is required.
NASA Technical Reports Server (NTRS)
Bailey, Michael R. (Inventor); Simon, Julianna C. (Inventor); Crum, Lawrence A. (Inventor); Khokhlova, Vera A. (Inventor); Wang, Yak-Nam (Inventor); Sapozhnikov, Oleg A. (Inventor); Khokhlova, Tatiana D. (Inventor)
2016-01-01
The present technology is directed to methods of soft tissue emulsification using a mechanism of ultrasonic atomization inside gas or vapor cavities, and associated systems and devices. In several embodiments, for example, a method of non-invasively treating tissue includes pulsing ultrasound energy from the ultrasound source toward the target site in tissue. The ultrasound source is configured to emit high intensity focused ultrasound (HIFU) waves. The target site comprises a pressure-release interface of a gas or vapor cavity located within the tissue. The method continues by generating shock waves in the tissue to induce a lesion in the tissue at the target site. The method additionally includes characterizing the lesion based on a degree of at least one of a mechanical or thermal ablation of the tissue.
The effects of penile girth enhancement using injectable hyaluronic acid gel, a filler.
Kwak, Tae Il; Oh, MiMi; Kim, Je Jong; Moon, Du Geon
2011-12-01
Despites the debates on penile girth enhancement (PGE), demands for enhancement are increasing. Recently, various fillers have been widely used for soft tissue augmentation with proven efficacy and safety. To identify the feasibility and efficacy of PGE by injection of filler. Fifty patients with subjective small penis who visited Korea University Guro outpatient clinic were enrolled and prospectively followed. Restylane Sub-Q (Q-med, Upssala, Sweden) was injected into the fascial layer of penile body via 21G cannula with "Back & Forth Technique" and homogenized with a roller. From April 2006 to February 2008, 50 patients were enrolled and 41 patients were followed until 18 months after PGE. Changes in penile girth at midshaft were measured by tapeline at 1 and 18 months. Patient's visual estimation of residual volume (Gr 0-4), patient's satisfaction (Gr 0-4), and any adverse reactions were also evaluated. Mean injected volume was 20.56 cc (18-22). Compared with basal girth of 7.48 ± 0.35 cm, maximal circumference was significantly increased to 11.41 ± 0.34 cm at 1 month (P < 0.0001) and maintained as 11.26 ± 0.33 cm until 18 months. In patient's visual estimation, two patients complained the decrease as Gr 3 with focal depression at 1 month. At 18 months, all patients answered as Gr 4 without asymmetry. Patient's and partner's satisfaction score was 3.71 ± 0.46 and 3.65 ± 0.48 at 1 month and 3.34 ± 0.53 and 3.38 ± 0.49 at 18 months. There were no inflammatory signs or serious adverse reactions in all cases. Considering the property of material, methods, and follow-up results of 18 months, PGE using filler is a very effective and safe technique for penile augmentation. © 2010 International Society for Sexual Medicine.
Penile Girth Enhancement With Polymethylmethacrylate-Based Soft Tissue Fillers.
Casavantes, Luis; Lemperle, Gottfried; Morales, Palmira
2016-09-01
An unknown percentage of men will take every risk to develop a larger penis. Thus far, most injectables have caused serious problems. Polymethylmethacrylate (PMMA) microspheres have been injected as a wrinkle filler and volumizer with increasing safety since 1989. To report on a safe and permanently effective method to enhance penile girth and length with an approved dermal filler (ie, PMMA). Since 2007, the senior author has performed penile augmentation in 752 men mainly with Metacrill, a suspension of PMMA microspheres in carboxymethyl-cellulose. The data of 729 patients and 203 completed questionnaires were evaluated statistically. The overall satisfaction rate was 8.7 on a scale of 1 to 10. After one to three injection sessions, average girth increased by 3.5 cm, or 134% (10.2 to 13.7 cm = 134.31%). Penile length also increased by weight and stretching force of the implant from an average of 9.8 to 10.5 cm. Approximately half the patients perceived some irregularities of the implant, which caused no problems. Complications occurred in 0.4%, when PMMA nodules had to be surgically removed in three of the 24% of patients who had a non-circumcised penis. After 5 years of development, penile augmentation with PMMA microspheres appears to be a natural, safe, and permanently effective method. The only complication of nodule formation and other irregularities can be overcome by an improved injection technique and better postimplantation care. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.
Periodontal tissue engineering strategies based on nonoral stem cells.
Requicha, João Filipe; Viegas, Carlos Alberto; Muñoz, Fernando; Reis, Rui Luís; Gomes, Manuela Estima
2014-01-01
Periodontal disease is an inflammatory disease which constitutes an important health problem in humans due to its enormous prevalence and life threatening implications on systemic health. Routine standard periodontal treatments include gingival flaps, root planning, application of growth/differentiation factors or filler materials and guided tissue regeneration. However, these treatments have come short on achieving regeneration ad integrum of the periodontium, mainly due to the presence of tissues from different embryonic origins and their complex interactions along the regenerative process. Tissue engineering (TE) aims to regenerate damaged tissue by providing the repair site with a suitable scaffold seeded with sufficient undifferentiated cells and, thus, constitutes a valuable alternative to current therapies for the treatment of periodontal defects. Stem cells from oral and dental origin are known to have potential to regenerate these tissues. Nevertheless, harvesting cells from these sites implies a significant local tissue morbidity and low cell yield, as compared to other anatomical sources of adult multipotent stem cells. This manuscript reviews studies describing the use of non-oral stem cells in tissue engineering strategies, highlighting the importance and potential of these alternative stem cells sources in the development of advanced therapies for periodontal regeneration. Copyright © 2013 Wiley Periodicals, Inc.
Wang, Yak-Nam; Khokhlova, Tatiana; Bailey, Michael; Hwang, Joo Ha; Khokhlova, Vera
2013-01-01
Recent studies have shown that shock wave heating and millisecond boiling in high intensity focused ultrasound (HIFU) fields can result in mechanical fractionation or emulsification of tissue - named boiling histotripsy. Visual observations of the change in color and contents indicated that the degree of thermal damage in the emulsified lesions can be controlled by varying the parameters of the exposure. The goal of this work was to examine thermal and mechanical effects in boiling histotripsy lesions using histological and biochemical analysis. The lesions were induced in ex vivo bovine heart and liver using a 2-MHz single-element transducer operating at duty factors of 0.005–0.01, pulse durations of 5–500 ms, and in situ shock amplitude of 73 MPa. Mechanical and thermal damage to tissue was evaluated histologically using conventional staining techniques (H&E and NADH-diphorase). Thermal effects were quantified by measuring denaturation of salt soluble proteins in the treated region. According to histology, the lesions that visually appeared as a liquid, contained no cellular structures larger than a cell nucleus and had a very sharp border of 1–2 cells. Both histology and protein analysis showed that lesions obtained with short pulses (< 10 ms) did not contain any thermal damage. Increasing the pulse duration resulted in an increase in thermal damage. However, both protein analysis and NADH-diaphorase staining showed less denaturation than visually observed as whitening of tissue. The number of HIFU pulses delivered per exposure did not change the lesion shape or the degree of thermal denaturation, whereas the size of the lesion showed a saturating behaviour thus suggesting optimal exposure duration. This study confirmed that boiling histotripsy offers an effective, predictable way to non-invasively fractionate tissue into subcellular fragments with or without inducing thermal damage. PMID:23312958
Working Memory in the Processing of Long-Distance Dependencies: Interference and Filler Maintenance
ERIC Educational Resources Information Center
Ness, Tal; Meltzer-Asscher, Aya
2017-01-01
During the temporal delay between the filler and gap sites in long-distance dependencies, the "active filler" strategy can be implemented in two ways: the filler phrase can be actively maintained in working memory ("maintenance account"), or it can be retrieved only when the parser posits a gap ("retrieval account").…
Polyvinyl alcohol battery separator containing inert filler. [alkaline batteries
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Hsu, L. C.; Manzo, M. A. (Inventor)
1981-01-01
A cross-linked polyvinyl alcohol battery separator is disclosed. A particulate filler, inert to alkaline electrolyte of an alkaline battery, is incorporated in the separator in an amount of 1-20% by weight, based on the weight of the polyvinyl alcohol, and is dispersed throughout the product. Incorporation of the filler enhances performance and increases cycle life of alkaline batteries when compared with batteries containing a similar separator not containing filler. Suitable fillers include titanates, silicates, zirconates, aluminates, wood floor, lignin, and titania. Particle size is not greater than about 50 microns.
Biodegradation of natural reinforcing fillers for polymer composites
NASA Astrophysics Data System (ADS)
Mastalygina, E. E.; Pantyukhov, P. V.; Popov, A. A.
2018-05-01
Twelve different natural raw materials were selected as possible fillers for eco-friendly biocomposites. The target was to find the most biodegradable ones. Two mycological tests were held: in the aqueous and agar media. It was found that two tests showed different results. In aqueous media, the fillers with a high content of water-soluble and easy-hydrolysed compounds demostrated the most intensive biofouling. In agar media, the entire filler was exposed to biodigestion by fungi. Therefore, multi-compound fillers with a set of different macro- and microelements were more biodegradable than others.
Recommendations for Filler Material Composition and Delivery Method for Bench-Scale Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, Ernest; Brady, Patrick Vane
This report supplements Joint Workplan on Filler Investigations for DPCs (SNL 2017) providing new and some corrected information for use in planning Phase 1 laboratory testing of slurry cements as possible DPC fillers. The scope description is to "Describe a complete laboratory testing program for filler composition, delivery, emplacement in surrogate canisters, and post-test examination. To the extent possible specify filler material and equipment sources." This report includes results from an independent expert review (Dr. Arun Wagh, retired from Argonne National Laboratory and contracted by Sandia) that helped to narrow the range of cement types for consideration, and to providemore » further guidance on mix variations to optimize injectability, durability, and other aspects of filler performance.« less
Hot cracking susceptibility of fillers 52 and 82 in alloy 690 welding
NASA Astrophysics Data System (ADS)
Wu, Weite; Tsai, C. H.
1999-02-01
The hot cracking susceptibility of fillers 52 and 82 in a alloy 690 weldment is analyzed by the Varestraint test. Weld characteristics, microstructure, hardness distribution, and thermal analysis of the two filler metals are also examined. The weld metal of both fillers develops an extremely dense oxide layer. A stainless steel brush cannot remove the oxide layer, and a grinder may be needed between weld passes to assure a sound weld. Differential temperature analysis (DTA) shows that filler 82 has a lower melting point and a wider melting/solidification temperature differential (Δ T). These characteristics correlate with greater hot cracking susceptibility of filler 82 than 52 in Varestraint tests. The hot cracks are intergranular and are caused by elements segregating in grain boundies.
NASA Astrophysics Data System (ADS)
Sreejith, M. P.; Balan, Aparna K.; Shaniba, V.; Jinitha, T. V.; Subair, N.; Purushothaman, E.
2017-06-01
Biodegradation behavior of styrene butadiene rubber composites reinforced with natural filler, coconut shell powder (CSP), with different filler loadings were carried out under soil burial conditions for three to six months. The extent of biodegradation of the composites was evaluated through weight loss, tensile strength and hardness measurements. It was observed that the permanence of the composites was remarkably dependent on filler modification, size of the filler particle and filler content. Composites containing silane modified filler were found to be more resistant to attack by the microbes present in the soil. Mechanical properties such as tensile strength, Young's modulus and hardness were decreased after soil burial testing due to the microbial attack onto the samples.
2010-11-01
results using human blood samples.14–16 Therefore, this study was performed to analyze the hemostatic efficacy of WS in coagulopathic subjects and to... zeolite ). Smectite is used in industries as filler in paints and rubber products and as a sealer and plasticizer in civil engineering for tunnel...180 minutes or until death. Angiography using the computed tomography method was performed on survivors, and local tissues were collected for
Hypercalcemia in a bodybuilder with cosmetic silicone injections.
Hamadeh, Majdi; Fares, Jawad; Maatouk, Khalil; Darwish, Mohamad
2018-04-13
Granulomatous hypercalcemia due to silicone injections is a rare disease with scarce literature. We present a case of a 35-year-old Caucasian male bodybuilder with multiple silicone injections in his upper extremities who developed hypercalcemia and urinary symptoms. He necessitated two sessions of dialysis. A biopsy of the upper arm showed granulomatous tissue. Corticosteroids were administered to relieve symptoms and reverse laboratory abnormalities. Silicone-induced hypercalcemia should be on high alert because of the increasing trend of body contour enhancements with injections, implants and fillers.
Geburek, Florian; Roggel, Florian; van Schie, Hans T M; Beineke, Andreas; Estrada, Roberto; Weber, Kathrin; Hellige, Maren; Rohn, Karl; Jagodzinski, Michael; Welke, Bastian; Hurschler, Christof; Conrad, Sabine; Skutella, Thomas; van de Lest, Chris; van Weeren, René; Stadler, Peter M
2017-06-05
Adipose tissue is a promising source of mesenchymal stromal cells (MSCs) for the treatment of tendon disease. The goal of this study was to assess the effect of a single intralesional implantation of adipose tissue-derived mesenchymal stromal cells (AT-MSCs) on artificial lesions in equine superficial digital flexor tendons (SDFTs). During this randomized, controlled, blinded experimental study, either autologous cultured AT-MSCs suspended in autologous inactivated serum (AT-MSC-serum) or autologous inactivated serum (serum) were injected intralesionally 2 weeks after surgical creation of centrally located SDFT lesions in both forelimbs of nine horses. Healing was assessed clinically and with ultrasound (standard B-mode and ultrasound tissue characterization) at regular intervals over 24 weeks. After euthanasia of the horses the SDFTs were examined histologically, biochemically and by means of biomechanical testing. AT-MSC implantation did not substantially influence clinical and ultrasonographic parameters. Histology, biochemical and biomechanical characteristics of the repair tissue did not differ significantly between treatment modalities after 24 weeks. Compared with macroscopically normal tendon tissue, the content of the mature collagen crosslink hydroxylysylpyridinoline did not differ after AT-MSC-serum treatment (p = 0.074) while it was significantly lower (p = 0.027) in lesions treated with serum alone. Stress at failure (p = 0.048) and the modulus of elasticity (p = 0.001) were significantly lower after AT-MSC-serum treatment than in normal tendon tissue. The effect of a single intralesional injection of cultured AT-MSCs suspended in autologous inactivated serum was not superior to treatment of surgically created SDFT lesions with autologous inactivated serum alone in a surgical model of tendinopathy over an observation period of 22 weeks. AT-MSC treatment might have a positive influence on collagen crosslinking of remodelling scar tissue. Controlled long-term studies including naturally occurring tendinopathies are necessary to verify the effects of AT-MSCs on tendon disease.
Increased tissue damage and lesion volumes in African Americans with multiple sclerosis.
Weinstock-Guttman, B; Ramanathan, M; Hashmi, K; Abdelrahman, N; Hojnacki, D; Dwyer, M G; Hussein, S; Bergsland, N; Munschauer, F E; Zivadinov, R
2010-02-16
African American (AA) patients with multiple sclerosis (MS) have more rapid disease progression and poorer responses to disease-modifying therapies than white American (WA) patients with MS. To investigate brain MRI characteristics in AA compared to WA in a cohort of consecutive patients with MS. We studied 567 patients with MS (age: 45.1 +/- SD 9.8 years, disease duration: 13.4 +/- 8.6 years), comprised of 488 WA and 79 AA. All patients obtained clinical and quantitative MRI evaluation. The majority of patients, 96% of AA and 94% of WA, were on disease-modifying therapies. The MRI measures included T1-, T2-, and gadolinium contrast-enhancing (CE) lesion volumes (LV) and CE number, global and tissue-specific brain atrophy, and magnetization transfer ratio (MTR) in lesions and normal-appearing gray matter (NAGM) and white matter (NAWM). The associations between race and clinical and MRI measurements were assessed in regression analysis. The MTR values in lesions and in NAGM and NAWM were significantly lower in AA compared to WA. The AA group had 31% greater T2-LV and 101% greater T1-LV compared to WA. The MS Severity Score for AA (mean +/- SD = 4.3 +/- 2.9) was greater than for WA (3.8 +/- 2.5), despite a shorter disease duration in AA, indicating more aggressive clinical disease. African American patients showed increased tissue damage, as measured by magnetization transfer ratio, and presented higher lesion volumes compared to white Americans. The greater tissue damage and faster lesion volume accumulation may explain the rapid clinical progression in African American patients.
An allogenic cell-based implant for meniscal lesions.
Weinand, Christian; Peretti, Giuseppe M; Adams, Samuel B; Bonassar, Lawrence J; Randolph, Mark A; Gill, Thomas J
2006-11-01
Meniscal tears in the avascular zones do not heal. Although tissue-engineering approaches using cells seeded onto scaffolds could expand the indication for meniscal repair, harvesting autologous cells could cause additional trauma to the patient. Allogenic cells, however, could provide an unlimited amount of cells. Allogenic cells from 2 anatomical sources can repair lesions in the avascular region of the meniscus. Controlled laboratory study. Both autologous and allogenic chondrocytes were seeded onto a Vicryl mesh scaffold and sutured into a bucket-handle lesion created in the medial menisci of 17 swine. Controls consisted of 3 swine knees treated with unseeded implants and controls from a previous experiment in which 4 swine were treated with suture only and 4 with no treatment. Menisci were harvested after 12 weeks and evaluated histologically for new tissue and percentage of interface healing surface; they were also evaluated statistically. The lesions were closed in 15 of 17 menisci. None of the control samples demonstrated healing. Histologic analysis of sequential cuts through the lesion showed formation of new scar-like tissue in all experimental samples. One of 8 menisci was completely healed in the allogenic group and 2 of 9 in the autologous group; the remaining samples were partially healed in both groups. No statistically significant differences in the percentage of healing were observed between the autologous and allogenic cell-based implants. Use of autologous and allogenic chondrocytes delivered via a biodegradable mesh enhanced healing of avascular meniscal lesions. This study demonstrates the potential of a tissue-engineered cellular repair of the meniscus using autologous and allogenic chondrocytes.
Micro-anatomical quantitative optical imaging: toward automated assessment of breast tissues.
Dobbs, Jessica L; Mueller, Jenna L; Krishnamurthy, Savitri; Shin, Dongsuk; Kuerer, Henry; Yang, Wei; Ramanujam, Nirmala; Richards-Kortum, Rebecca
2015-08-20
Pathologists currently diagnose breast lesions through histologic assessment, which requires fixation and tissue preparation. The diagnostic criteria used to classify breast lesions are qualitative and subjective, and inter-observer discordance has been shown to be a significant challenge in the diagnosis of selected breast lesions, particularly for borderline proliferative lesions. Thus, there is an opportunity to develop tools to rapidly visualize and quantitatively interpret breast tissue morphology for a variety of clinical applications. Toward this end, we acquired images of freshly excised breast tissue specimens from a total of 34 patients using confocal fluorescence microscopy and proflavine as a topical stain. We developed computerized algorithms to segment and quantify nuclear and ductal parameters that characterize breast architectural features. A total of 33 parameters were evaluated and used as input to develop a decision tree model to classify benign and malignant breast tissue. Benign features were classified in tissue specimens acquired from 30 patients and malignant features were classified in specimens from 22 patients. The decision tree model that achieved the highest accuracy for distinguishing between benign and malignant breast features used the following parameters: standard deviation of inter-nuclear distance and number of duct lumens. The model achieved 81 % sensitivity and 93 % specificity, corresponding to an area under the curve of 0.93 and an overall accuracy of 90 %. The model classified IDC and DCIS with 92 % and 96 % accuracy, respectively. The cross-validated model achieved 75 % sensitivity and 93 % specificity and an overall accuracy of 88 %. These results suggest that proflavine staining and confocal fluorescence microscopy combined with image analysis strategies to segment morphological features could potentially be used to quantitatively diagnose freshly obtained breast tissue at the point of care without the need for tissue preparation.
NASA Astrophysics Data System (ADS)
Singh-Moon, Rajinder P.; Hendon, Christine P.
2016-02-01
Despite considerable advances in guidance of radiofrequency ablation (RFA) therapies for atrial fibrillation, success rates have been hampered by an inability to intraoperatively characterize the extent of permanent injury. Insufficient lesions can elusively create transient conduction blockages that eventually reconduct. Prior studies suggest significantly greater met-myoglobin (Mmb) concentrations in the lesion core than those in the healthy myocardium and may serve as a marker for irreversible tissue damage. In this work, we present real-time monitoring of permanent injury through spectroscopic assessment of Mmb concentrations at the catheter tip. Atrial wedges (n=6) were excised from four fresh swine hearts and submerged under pulsatile flow of warm (37oC) phosphate buffered saline. A commercial RFA catheter inserted into a fiber optic sheath allowed for simultaneous measurement of tissue diffuse reflectance (DR) spectra (500-650nm) during application of RF energy. Optical measurements were continuously acquired before, during, and post-ablation, in addition to healthy neighboring tissue. Met-myoglobin, oxy-myoglobin, and deoxy-myoglobin concentrations were extracted from each spectrum using an inverse Monte Carlo method. Tissue injury was validated with Masson's trichrome and hematoxylin and eosin staining. Time courses revealed a rapid increase in tissue Mmb concentrations at the onset of RFA treatment and a gradual plateauing thereafter. Extracted Mmb concentrations were significantly greater post-ablation (p<0.0001) as compared to healthy tissue and correlated well with histological assessment of severe thermal tissue destruction. On going studies are aimed at integrating these findings with prior work on near infrared spectroscopic lesion depth assessment. These results support the use of spectroscopy-facilitated guidance of RFA therapies for real-time permanent injury estimation.
Dai, Zhenyu; Chen, Fei; Yao, Lizheng; Dong, Congsong; Liu, Yang; Shi, Haicun; Zhang, Zhiping; Yang, Naizhong; Zhang, Mingsheng; Dai, Yinggui
2015-08-18
To evaluate the clinical application value of diffusion tensor imaging (DTI) and diffusion tensor tractography (DTT) in judging infarction time phase of acute ischemic cerebral infarction. To retrospective analysis DTI images of 52 patients with unilateral acute ischemic cerebral infarction (hyper-acute, acute and sub-acute) from the Affiliated Yancheng Hospital of Southeast University Medical College, which diagnosed by clinic and magnetic resonance imaging. Set the regions of interest (ROIs) of infarction lesions, brain tissue close to infarction lesions and corresponding contra (contralateral normal brain tissue) on DTI parameters mapping of fractional anisotropy (FA), volume ratio anisotropy (VRA), average diffusion coefficient (DCavg) and exponential attenuation (Exat), record the parameters values of ROIs and calculate the relative parameters value of infarction lesion to contra. Meanwhile, reconstruct the DTT images based on the seed points (infarction lesion and contra). The study compared each parameter value of infarction lesions, brain tissue close to infarction lesions and corresponding contra, also analysed the differences of relative parameters values in different infarction time phases. The DTT images of acute ischemic cerebral infarction in each time phase could show the manifestation of fasciculi damaged. The DCavg value of cerebral infarction lesions was lower and the Exat value was higher than contra in each infarction time phase (P<0.05). The FA and VRA value of cerebral infarction lesions were reduced than contra only in acute and sub-acute infarction (P<0.05). The FA, VRA and Exat value of brain tissue close to infarction lesions were increased and DCavg value was decreased than contra in hyper-acute infarction (P<0.05). There were no statistic differences of FA, VRA, DCavg and Exat value of brain tissue close to infarction lesions in acute and sub-acute infarction. The relative FA and VRA value of infarction lesion to contra gradually decreased from hyper-acute to sub-acute cerebral infarction (P<0.05), but there were no difference of the relative VRA value between acute and sub-acute cerebral infarction. The relative DCavg value of infarction lesion to contra in hyper-acute infarction than that in acute and sub-acute infarction (P<0.05), however there was also no difference between acute and sub-acute infarction. ROC curve showed the best diagnosis cut off value of relative FA, VRA and DCavg of infarction lesions to contra were 0.852, 0.886 and 0.541 between hyper-acute and acute cerebral infarction, the best diagnosis cut off value of relative FA was 0.595 between acute and sub-acute cerebral infarction, respectively. The FA, VRA, DCavg and Exat value have specific change mode in acute ischemic cerebral infarction of different infarction time phases, which can be combine used in judging infarction time phase of acute ischemic cerebral infarction without clear onset time, thus to help selecting the reasonable treatment protocols.
NASA Astrophysics Data System (ADS)
Bertazzo, Sergio; Gentleman, Eileen; Cloyd, Kristy L.; Chester, Adrian H.; Yacoub, Magdi H.; Stevens, Molly M.
2013-06-01
The accumulation of calcified material in cardiovascular tissue is thought to involve cytochemical, extracellular matrix and systemic signals; however, its precise composition and nanoscale architecture remain largely unexplored. Using nano-analytical electron microscopy techniques, we examined valves, aortae and coronary arteries from patients with and without calcific cardiovascular disease and detected spherical calcium phosphate particles, regardless of the presence of calcific lesions. We also examined lesions after sectioning with a focused ion beam and found that the spherical particles are composed of highly crystalline hydroxyapatite that crystallographically and structurally differs from bone mineral. Taken together, these data suggest that mineralized spherical particles may play a fundamental role in calcific lesion formation. Their ubiquitous presence in varied cardiovascular tissues and from patients with a spectrum of diseases further suggests that lesion formation may follow a common process. Indeed, applying materials science techniques to ectopic and orthotopic calcification has great potential to lend critical insights into pathophysiological processes underlying calcific cardiovascular disease.
NASA Astrophysics Data System (ADS)
Weinberg, Brent D.; Lazebnik, Roee S.; Breen, Michael S.; Lewin, Jonathan S.; Wilson, David L.
2003-05-01
Using magnetic resonance imaging (MRI), real-time guidance is feasible for radiofrequency (RF) current ablation of pathologic tissue. Lesions have a characteristic two-zone appearance: an inner core (Zone I) surrounded by a hyper-intense rim (Zone II). A better understanding of both the immediate (hyper-acute) and delayed (sub-acute) physiological response of the target tissue will aid development of minimally invasive tumor treatment strategies. We performed in vivo RF ablations in a rabbit thigh model and characterized the tissue response to treatment through contrast enhanced (CE) T1 and T2 weighted MR images at two time points. We measured zonal grayscale changes as well as zone volume changes using a 3D computationally fitted globally deformable parametric model. Comparison over time demonstrated an increase in the volume of both the inner necrotic core (mean 56.5% increase) and outer rim (mean 16.8% increase) of the lesion. Additionally, T2 images of the lesion exhibited contrast greater than or equal to CE T1 (mean 35% improvement). This work establishes a foundation for the clinical use of T2 MR images coupled with a geometric model of the ablation for noninvasive lesion monitoring and characterization.
Sullivan, L E; Evans, N J; Blowey, R W; Grove-White, D H; Clegg, S R; Duncan, J S; Carter, S D
2015-07-09
Bovine digital dermatitis (BDD) is an infective foot disease commonly reported in dairy cattle where Treponema are considered as the primary causative infectious agents. There still remains little definitive information on the etiology of BDD in beef cattle suggesting further investigations are warranted. Beef BDD lesions (n=34) and healthy beef foot tissues (n=38) were analysed by PCR for three BDD-associated Treponema phylogroups and also for Dichelobacter nodosus and Fusobacterium necrophorum. Spirochete culture was attempted on all BDD lesion samples. One or more BDD-associated Treponema phylogroups were detected in 100% of beef BDD lesions. "Treponema medium/Treponema vincentii-like", "Treponema phagedenis-like" and Treponema pedis spirochetes were identified in 27/34 (79%), 31/34 (91%) and 24/34 (71%) of BDD lesions, respectively. No BDD-associated treponeme DNA was amplified from beef healthy foot tissues. D. nodosus and F. necrophorum were present in 24/34 (71%) and 15/34 (44%) of lesions and 10/38 (26%) and 12/38 (32%) of healthy foot tissues, respectively. Twenty spirochetes were isolated from beef BDD lesions; 19 were representatives of the three BDD-associated Treponema phylogroups. One spirochete isolate shared less than 97% 16S rRNA gene similarity to the three cultivable BDD-associated Treponema phylogroups and therefore may represent a novel taxa of Treponema. Upon comparison, sheep contagious ovine digital dermatitis (CODD), dairy cattle and beef cattle BDD lesions appear to have extremely similar bacteriological data and therefore provides evidence of a shared etiopathogenesis posing concerns for cross-species transmission. Copyright © 2015 Elsevier B.V. All rights reserved.
Eisenbrey, John R; Dave, Jaydev K; Merton, Daniel A; Palazzo, Juan P; Hall, Anne L; Forsberg, Flemming
2011-01-01
Parametric maps showing perfusion of contrast media can be useful tools for characterizing lesions in breast tissue. In this study we show the feasibility of parametric subharmonic imaging (SHI), which allows imaging of a vascular marker (the ultrasound contrast agent) while providing near complete tissue suppression. Digital SHI clips of 16 breast lesions from 14 women were acquired. Patients were scanned using a modified LOGIQ 9 scanner (GE Healthcare, Waukesha, WI) transmitting/receiving at 4.4/2.2 MHz. Using motion-compensated cumulative maximum intensity (CMI) sequences, parametric maps were generated for each lesion showing the time to peak (TTP), estimated perfusion (EP), and area under the time-intensity curve (AUC). Findings were grouped and compared according to biopsy results as benign lesions (n = 12, including 5 fibroadenomas and 3 cysts) and carcinomas (n = 4). For each lesion CMI, TTP, EP, and AUC parametric images were generated. No significant variations were detected with CMI (P = .80), TTP (P = .35), or AUC (P = .65). A statistically significant variation was detected for the average pixel EP (P = .002). Especially, differences were seen between carcinoma and benign lesions (mean ± SD, 0.10 ± 0.03 versus 0.05 ± 0.02 intensity units [IU]/s; P = .0014) and between carcinoma and fibroadenoma (0.10 ± 0.03 versus 0.04 ± 0.01 IU/s; P = .0044), whereas differences between carcinomas and cysts were found to be nonsignificant. In conclusion, a parametric imaging method for characterization of breast lesions using the high contrast to tissue signal provided by SHI has been developed. While the preliminary sample size was limited, results show potential for breast lesion characterization based on perfusion flow parameters.
Selecting fillers on emotional appearance improves lineup identification accuracy.
Flowe, Heather D; Klatt, Thimna; Colloff, Melissa F
2014-12-01
Mock witnesses sometimes report using criminal stereotypes to identify a face from a lineup, a tendency known as criminal face bias. Faces are perceived as criminal-looking if they appear angry. We tested whether matching the emotional appearance of the fillers to an angry suspect can reduce criminal face bias. In Study 1, mock witnesses (n = 226) viewed lineups in which the suspect had an angry, happy, or neutral expression, and we varied whether the fillers matched the expression. An additional group of participants (n = 59) rated the faces on criminal and emotional appearance. As predicted, mock witnesses tended to identify suspects who appeared angrier and more criminal-looking than the fillers. This tendency was reduced when the lineup fillers matched the emotional appearance of the suspect. Study 2 extended the results, testing whether the emotional appearance of the suspect and fillers affects recognition memory. Participants (n = 1,983) studied faces and took a lineup test in which the emotional appearance of the target and fillers was varied between subjects. Discrimination accuracy was enhanced when the fillers matched an angry target's emotional appearance. We conclude that lineup member emotional appearance plays a critical role in the psychology of lineup identification. The fillers should match an angry suspect's emotional appearance to improve lineup identification accuracy. PsycINFO Database Record (c) 2014 APA, all rights reserved.
NASA Astrophysics Data System (ADS)
Hashim, M. F. Abu; Abdullah, M. M. A.; Ghazali, C. M. R.; Hussin, K.; Binhussain, M.
2017-04-01
This study investigated the use of a novel white clay geopolymer as a filler to produce high strength glass reinforced epoxy pipe. It was found that using white clay geopolymer as filler gives better compressive strength to the glass reinforced epoxy pipe. The disadvantages of current glass reinforced epoxy pipes such low compressive strength which can be replaced by the composite pipes. Geopolymerization is an innovative technology that can transform several aluminosilicate materials into useful products called geopolymers or inorganic polymers. A series of glass reinforced epoxy pipe and glass reinforced epoxy pipe filled with 10 - 40 weight percentages white clay geopolymer filler with 4 Molarity and 8 Molarity were prepared. Morphology of white clay geopolymer filler surface was indicates using scanning electron microscopy. The additions of white clay geopolymer filler for both 4 Molarity and 8 Molarity show higher compressive strength than glass reinforced epoxy pipe without any geopolymer filler. The compressive test of these epoxy geopolymer pipe samples was determined using Instron Universal Testing under compression mode. Nonetheless, the compressive strength of glass reinforced epoxy pipe with white clay geopolymer filler continues to drop when added to 40 wt% of the geopolymer filler loading for both 4 Molarity and 8 Molarity. These outcomes showed that the mixing of geopolymer materials in epoxy system can be attained in this research.
Feng, Dilu; Menger, Michael D; Wang, Hongbo; Laschke, Matthias W
2014-02-01
In endometriosis research, endometriosis-like lesions are usually induced in rodents by transplantation of isolated endometrial tissue fragments to ectopic sites. In the present study, we investigated whether this approach is affected by the cellular composition of the grafts. For this purpose, endometrial tissue fragments covered with luminal epithelium (LE(+)) and without luminal epithelium (LE(-)) were transplanted from transgenic green-fluorescent-protein-positive (GFP(+)) donor mice into the dorsal skinfold chamber of GFP(-) wild-type recipient animals to analyze their vascularization, growth and morphology by means of repetitive intravital fluorescence microscopy, histology and immunohistochemistry during a 14-day observation period. LE(-) fragments developed into typical endometriosis-like lesions with cyst-like dilated endometrial glands and a well-vascularized endometrial stroma. In contrast, LE(+) fragments exhibited a polypoid morphology and a significantly reduced blood perfusion after engraftment, because the luminal epithelium prevented the vascular interconnection with the microvasculature of the surrounding host tissue. This was associated with a markedly decreased growth rate of LE(+) lesions compared with LE(-) lesions. In addition, we found that many GFP(+) microvessels grew outside the LE(-) lesions and developed interconnections to the host microvasculature, indicating that inosculation is an important mechanism in the vascularization process of endometriosis-like lesions. Our findings demonstrate that the luminal epithelium crucially affects the vascularization, growth and morphology of endometriosis-like lesions. Therefore, it is of major importance to standardize the cellular composition of endometrial grafts in order to increase the validity and reliability of pre-clinical rodent studies in endometriosis research.
Differentiation of benign and malignant breast lesions by mechanical imaging
Kearney, Thomas; Pollak, Stanley B.; Rohatgi, Chand; Sarvazyan, Noune; Airapetian, Suren; Browning, Stephanie; Sarvazyan, Armen
2009-01-01
Mechanical imaging yields tissue elasticity map and provides quantitative characterization of a detected pathology. The changes in the surface stress patterns as a function of applied load provide information about the elastic composition and geometry of the underlying tissue structures. The objective of this study is the clinical evaluation of breast mechanical imager for breast lesion characterization and differentiation between benign and malignant lesions. The breast mechanical imager includes a probe with pressure sensor array, an electronic unit providing data acquisition from the pressure sensors and communication with a touch-screen laptop computer. We have developed an examination procedure and algorithms to provide assessment of breast lesion features such as hardness related parameters, mobility, and shape. A statistical Bayesian classifier was constructed to distinguish between benign and malignant lesions by utilizing all the listed features as the input. Clinical results for 179 cases, collected at four different clinical sites, have demonstrated that the breast mechanical imager provides a reliable image formation of breast tissue abnormalities and calculation of lesion features. Malignant breast lesions (histologically confirmed) demonstrated increased hardness and strain hardening as well as decreased mobility and longer boundary length in comparison with benign lesions. Statistical analysis of differentiation capability for 147 benign and 32 malignant lesions revealed an average sensitivity of 91.4% and specificity of 86.8% with a standard deviation of ±6.1%. The area under the receiver operating characteristic curve characterizing benign and malignant lesion discrimination is 86.1% with the confidence interval ranging from 80.3 to 90.9%, with a significance level of P = 0.0001 (area = 50%). The multisite clinical study demonstrated the capability of mechanical imaging for characterization and differentiation of benign and malignant breast lesions. We hypothesize that the breast mechanical imager has the potential to be used as a cost effective device for cancer diagnostics that could reduce the benign biopsy rate, serve as an adjunct to mammography and to be utilized as a screening device for breast cancer detection. PMID:19306059
Design and Evaluation of Complex Moving HIFU Treatment Protocols
NASA Astrophysics Data System (ADS)
Kargl, Steven G.; Andrew, Marilee A.; Kaczkowski, Peter J.; Brayman, Andrew A.; Crum, Lawrence A.
2005-03-01
The use of moving high-intensity focused ultrasound (HIFU) treatment protocols is of interest in achieving efficient formation of large-volume thermal lesions in tissue. Judicious protocol design is critical in order to avoid collateral damage to healthy tissues outside the treatment zone. A KZK-BHTE model, extended to simulate multiple, moving scans in tissue, is used to investigate protocol design considerations. Prediction and experimental observations are presented which 1) validate the model, 2) illustrate how to assess the effects of acoustic nonlinearity, and 3) demonstrate how to assess and control collateral damage such as prefocal lesion formation and lesion formation resulting from thermal conduction without direct HIFU exposure. Experimental data consist of linear and circular scan protocols delivered over a range of exposure regimes in ex vivo bovine liver.
Effect of filler type and polishing on the discoloration of composite resin artificial teeth.
Imamura, Soichiro; Takahashi, Hidekazu; Hayakawa, Iwao; Loyaga-Rendon, Paola G; Minakuchi, Shunsuke
2008-11-01
In this study, the effects of filler type and polishing on the discoloration of composite resin artificial teeth were examined. Four types of experimental resins were prepared: one was a matrix resin, while the others were composite resins containing three different types of fillers (nano-sized silica filler with or without silanization, and prepolymerized filler). Specimens were immersed in distilled water, coffee, red wine, or curry. Color change after immersion was measured using a colorimeter. Color difference values (delta E) and changes in translucency parameter (delta TP) were statistically analyzed using three-way ANOVA and Tukey's comparison. On the influence of the polishing factor, statistically significant differences were neither observed in delta E nor delta TP between polished and non-polished tooth surfaces. On the contrary, the influences of filler type and discoloration medium, and their interaction thereof, were significant. With unsilanized filler, the delta E value of composite resin artificial teeth was significantly increased.
NASA Astrophysics Data System (ADS)
Zykova, A. K.; Pantyukhov, P. V.; Kolesnikova, N. N.; Popov, A. A.; Olkhov, A. A.
2015-10-01
Biocomposites based on low density polyethylene (LDPE) and birch wood flour (WF) were investigated. The mechanical properties and water absorption capacity were examined depending on the particle size of a filler in biocomposites. The aim of the paper is the investigation of composite properties depending on the filler particle size. The filler particle sizes were 0-80 µm, 80-140 µm, 140-200 µm, and 0-200 µm. The tensile strength of composite samples varied within the range 5.7-8.2 MPa. Elongation at break of composites varied within the range 5.1-7.5%. Highest mechanical properties were found in composites with the lowest filler fraction. Highest water absorption was observed in composition with a complex fraction of the filler. The influence of the filler particle size on composite properties was shown. It was found that an increase of the filler particle size decreases mechanical parameters and increases water absorption.
Advanced inorganic separators for alkaline batteries
NASA Technical Reports Server (NTRS)
Sheibley, D. W. (Inventor)
1982-01-01
A flexible, porous battery separator comprising a coating applied to a porous, flexible substrate is described. The coating comprises: (1) a thermoplastic rubber-based resin which is insoluble and unreactive in the alkaline electrolyte; (2) a polar organic plasticizer which is reactive with the alkaline electrolyte to produce a reaction product which contains a hydroxyl group and/or a carboxylic acid group; and (3) a mixture of polar particulate filler materials which are unreactive with the electrolyte, the mixture comprising at least one first filler material having a surface area of greater than 25 meters sq/gram, at least one second filler material having a surface area of 10 to 25 sq meters/gram, wherein the volume of the mixture of filler materials is less than 45% of the total volume of the fillers and the binder, the filler surface area per gram of binder is about 20 to 60 sq meters/gram, and the amount of plasticizer is sufficient to coat each filler particle. A method of forming the battery separator is also described.
Advanced inorganic separators for alkaline batteries and method of making the same
NASA Technical Reports Server (NTRS)
Sheibley, D. W. (Inventor)
1983-01-01
A flexible, porous battery separator includes a coating applied to a porous, flexible substrate. The coating comprises: (1) a thermoplastic rubber-based resin which is insoluble and unreactive in the alkaline electrolyte, (2) a polar organic plasticizer which is reactive with the alkaline electrolyte to produce a reaction product which contains a hydroxyl group and/or a carboxylic acid group, and (3) a mixture of polar particulate filler materials which are unreactive with the electrode. The mixture comprises at least one first filler material having a surface area of greater than 25 sq meters/gram, at last one second filler material having a surface area of 10 to 25 sq meters/gram. The volume of the mixture of filler materials is less than 45% of the total volume of the fillers and the binder. The filler surface area per gram of binder is about 20 to 60 sq meters/gram, and the amount of plasticizer is sufficient to coat each filler particle.
Strzemiecka, Beata; Klapiszewski, Łukasz; Jamrozik, Artur; Szalaty, Tadeusz J.; Matykiewicz, Danuta; Sterzyński, Tomasz; Voelkel, Adam; Jesionowski, Teofil
2016-01-01
Functional lignin–SiO2 hybrid fillers were prepared for potential application in binders for phenolic resins, and their chemical structure was characterized. The properties of these fillers and of composites obtained from them with phenolic resin were compared with those of systems with lignin or silica alone. The chemical structure of the materials was investigated by Fourier transform infrared spectroscopy (FT-IR) and carbon-13 nuclear magnetic resonance spectroscopy (13C CP MAS NMR). The thermal stability of the new functional fillers was examined by thermogravimetric analysis–mass spectrometry (TG-MS). Thermo-mechanical properties of the lignin–silica hybrids and resin systems were investigated by dynamic mechanical thermal analysis (DMTA). The DMTA results showed that abrasive composites with lignin–SiO2 fillers have better thermo-mechanical properties than systems with silica alone. Thus, fillers based on lignin might provide new, promising properties for the abrasive industry, combining the good properties of lignin as a plasticizer and of silica as a filler improving mechanical properties. PMID:28773639
Koc, Baris B; Somorjai, Nicolaas; P M Kiesouw, Egid; Vanderdood, Kurt; Meesters-Caberg, Marleen; Draijer, Frits W; Jansen, Edwin J P
2017-01-01
A Morel-Lavallée lesion is a post-traumatic closed degloving injury of soft tissue. The lesion is due to a shearing trauma with separation of subcutaneous tissue from underlying fascia. When conservative treatment fails, surgical treatment is imperative. Commonly, open drainage and debridement is performed. This case report describes a Morel-Lavallée lesion of the knee in a professional soccer player who was successfully treated with endoscopic debridement and fibrin glue injection after failure of conservative management. This method achieves the goal of an open surgical debridement without exposing patients to an increased morbidity. Copyright © 2016. Published by Elsevier B.V.
Marshall, Ian; Thrippleton, Michael J; Bastin, Mark E; Mollison, Daisy; Dickie, David A; Chappell, Francesca M; Semple, Scott I K; Cooper, Annette; Pavitt, Sue; Giovannoni, Gavin; Wheeler-Kingshott, Claudia A M Gandini; Solanky, Bhavana S; Weir, Christopher J; Stallard, Nigel; Hawkins, Clive; Sharrack, Basil; Chataway, Jeremy; Connick, Peter; Chandran, Siddharthan
2018-05-30
Proton magnetic resonance spectroscopy yields metabolic information and has proved to be a useful addition to structural imaging in neurological diseases. We applied short-echo time Spectroscopic Imaging in a cohort of 42 patients with secondary progressive multiple sclerosis (SPMS). Linear modelling with respect to brain tissue type yielded metabolite levels that were significantly different in white matter lesions compared with normal-appearing white matter, suggestive of higher myelin turnover (higher choline), higher metabolic rate (higher creatine) and increased glial activity (higher myo-inositol) within the lesions. These findings suggest that the lesions have ongoing cellular activity that is not consistent with the usual assumption of 'chronic' lesions in SPMS, and may represent a target for repair therapies.
The connective tissue component of the caprine arthritis-encephalitis syndrome.
Crawford, T. B.; Adams, D. S.; Sande, R. D.; Gorham, J. R.; Henson, J. B.
1980-01-01
The gross and microscopic connective tissue lesions in 12 goats with caprine arthritis-encephalitis (CAE) are described, including those from which a virus (CAEV) was isolated. Lesions were most often associated with synovial-lined structures including joints, tendon sheaths, and bursae, and were typified by synovial cell proliferations, subsynovial mononuclear cell infiltration, the presence of fibrin, fibrinous concretions, necrosis, and mineralization. Extrasynovial lesions were located in kidneys, vessels, and brain. The inflammatory infiltrates in these organs were predominantly mononuclear. Amyloid was also found in liver, spleen, and kidney. Microbiologic techniques failed to demonstrate any bacteria, mycoplasma, or chlamydia in the lesions. Images Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 1 Figure 2 Figure 3 Figure 4 PMID:7406019
Chennoju, Sai Kiran; Pachigolla, Ramaswamy; Govada, Vanya Mahitha; Alapati, Satish; Balla, Smitha
2016-05-01
Bone dysplasias comprise of a condition where the normal bone is replaced with fibrous tissue. Periapical Cemento-Osseous Dysplasia (PCOD) is a benign fibro-osseous condition where bone tissue is supplanted with fibrous tissue and cementum-like material. This condition affects mostly mandibular anterior region and rarely occurs in the maxilla. PCOD is seen above 30 years of age and has slight female predilection. Generally the teeth related to such lesions appear to be vital and are usually asymptomatic. These lesions are mostly seen during routine radiographic examination whose presentation may vary from complete radiolucency to dense radiopacity. The advent of Cone Beam Computed Tomography (CBCT) has brought a massive change in the field of dentistry which has become an important tool for diagnosis. Hence we hereby present an unusual case of cemento-osseous dysplasia in an unfamiliar location with an atypical presentation. The shape of the pathology was completely idiosyncratic and different from an orthodox lesion of COD, as the lesion was observed to grow out of the palatal surface with a prominent palatal expansion. This case highlights the importance of CBCT in radiographic diagnosis and in evaluating the characteristics of such lesion, which present with high diagnostic dilemma.
Vibrational mapping of sinonasal lesions by Fourier transform infrared imaging spectroscopy
NASA Astrophysics Data System (ADS)
Giorgini, Elisabetta; Sabbatini, Simona; Conti, Carla; Rubini, Corrado; Rocchetti, Romina; Re, Massimo; Vaccari, Lisa; Mitri, Elisa; Librando, Vito
2015-12-01
Fourier transform infrared imaging (FTIRI) is a powerful tool for analyzing biochemical changes in tumoral tissues. The head and neck region is characterized by a great variety of lesions, with different degrees of malignancy, which are often difficult to diagnose. Schneiderian papillomas are sinonasal benign neoplasms arising from the Schneiderian mucosa; they can evolve into malignant tumoral lesions (squamous cell carcinoma). In addition, they can sometimes be confused with the more common inflammatory polyps. Therefore, an early and definitive diagnosis of this pathology is mandatory. Progressing in our research on the study of oral cavity lesions, 15 sections consisting of inflammatory sinonasal polyps, benign Schneiderian papillomas, and sinonasal undifferentiated carcinomas were analyzed using FTIRI. To allow a rigorous description of these pathologies and to gain objective diagnosis, the epithelial layer and the adjacent connective tissue of each section were separately investigated by following a multivariate analysis approach. According to the nature of the lesion, interesting modifications were detected in the average spectra of the different tissue components, above all in the lipid and protein patterns. Specific band-area ratios acting as spectral markers of the different pathologies were also highlighted.
Gross and microscopic pathology of hard and soft corals in New Caledonia
Work, Thierry M.; Aeby, Greta S.; Lasne, Gregory; Tribollet, Aline
2014-01-01
We surveyed the reefs of Grande Terre, New Caledonia, for coral diseases in 2010 and 2013. Lesions encountered in hard and soft corals were systematically described at the gross and microscopic level. We sampled paired and normal tissues from 101 and 65 colonies in 2010 and 2013, respectively, comprising 51 species of corals from 27 genera. Tissue loss was the most common gross lesion sampled (40%) followed by discoloration (28%), growth anomalies (13%), bleaching (10%), and flatworm infestation (1%). When grouped by gross lesions, the diversity of microscopic lesions as measured by Shannon–Wiener index was highest for tissue loss, followed by discoloration, bleaching, and growth anomaly. Our findings document an extension of the range of certain diseases such as Porites trematodiasis and endolithic hypermycosis (dark spots) to the Western Pacific as well as the presence of a putative cnidarian endosymbiont. We also expand the range of species infected by cell-associated microbial aggregates, and confirm the trend that these aggregates predominate in dominant genera of corals in the Indo-Pacific. This study highlights the importance of including histopathology as an integral component of baseline coral disease surveys, because a given gross lesion might be associated with multiple potential causative agents.
Quantitative characterization of brazing performance for Sn-plated silver alloy fillers
NASA Astrophysics Data System (ADS)
Wang, Xingxing; Peng, Jin; Cui, Datian
2017-12-01
Two types of AgCuZnSn fillers were prepared based on BAg50CuZn and BAg34CuZnSn alloy through a combinative process of electroplating and thermal diffusion. The models of wetting entropy and joint strength entropy of AgCuZnSn filler metals were established. The wetting entropy of the Sn-plated silver brazing alloys are lower than the traditional fillers, and its joint strength entropy value is slightly higher than the latter. The wetting entropy value of the Sn-plated brazing alloys and traditional filler metal are similar to the change trend of the wetting area. The trend of the joint strength entropy value with those fillers are consisted with the tensile strength of the stainless steel joints with the increase of Sn content.
Hot cracking susceptibility of fillers 52 and 82 in alloy 690 welding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, W.; Tsai, C.H.
1999-02-01
The hot cracking susceptibility of fillers 52 and 82 in a alloy 690 weldment is analyzed by the Varestraint test. Weld characteristics, microstructure, hardness distribution, and thermal analysis of the two filler metals are also examined. The weld metal of both fillers develops an extremely dense oxide layer. A stainless steel brush cannot remove the oxide layer, and a grinder may be needed between weld passes to assure a sound weld. Differential temperature analysis (DTA) shows that filler 82 has a lower melting point and a wider melting/solidification temperature differential ({Delta} T). These characteristics correlate with greater hot cracking susceptibilitymore » of filler 82 than 52 in Varestraint tests. The hot cracks are intergranular and are caused by elements segregating in grain boundaries.« less
Shear wave elastography in medullary thyroid carcinoma diagnostics.
Dobruch-Sobczak, Katarzyna; Gumińska, Anna; Bakuła-Zalewska, Elwira; Mlosek, Krzysztof; Słapa, Rafał Z; Wareluk, Paweł; Krauze, Agnieszka; Ziemiecka, Agnieszka; Migda, Bartosz; Jakubowski, Wiesław; Dedecjus, Marek
2015-12-01
Shear wave elastography (SWE) is a modern method for the assessment of tissue stiffness. There has been a growing interest in the use of this technique for characterizing thyroid focal lesions, including preoperative diagnostics. The aim of the study was to assess the clinical usefulness of SWE in medullary thyroid carcinoma (MTC) diagnostics. A total of 169 focal lesions were identified in the study group (139 patients), including 6 MTCs in 4 patients (mean age: 45 years). B-mode ultrasound and SWE were performed using Aixplorer (SuperSonic, Aix-en-Provence), with a 4-15 MHz linear probe. The ultrasound was performed to assess the echogenicity and echostructure of the lesions, their margin, the halo sign, the height/width ratio (H/W ratio), the presence of calcifications and the vascularization pattern. This was followed by an analysis of maximum and mean Young's (E) modulus values for MTC (EmaxLR, EmeanLR) and the surrounding thyroid tissues (EmaxSR, EmeanSR), as well as mean E-values (EmeanLRz) for 2 mm region of interest in the stiffest zone of the lesion. The lesions were subject to pathological and/or cytological evaluation. The B-mode assessment showed that all MTCs were hypoechogenic, with no halo sign, and they contained micro- and/ or macrocalcifications. Ill-defined lesion margin were found in 4 out of 6 cancers; 4 out of 6 cancers had a H/W ratio > 1. Heterogeneous echostructure and type III vascularity were found in 5 out of 6 lesions. In the SWE, the mean value of EmaxLR for all of the MTCs was 89.5 kPa and (the mean value of EmaxSR for all surrounding tissues was) 39.7 kPa Mean values of EmeanLR and EmeanSR were 34.7 kPa and 24.4 kPa, respectively. The mean value of EmeanLRz was 49.2 kPa. SWE showed MTCs as stiffer lesions compared to the surrounding tissues. The lesions were qualified for fine needle aspiration biopsy based on B-mode assessment. However, the diagnostic algorithm for MTC is based on the measurement of serum calcitonin levels, B-mode ultrasound and FNAB.
NASA Astrophysics Data System (ADS)
Collier, Michael A.; Haugland, L. Mark; Bellamy, Janine; Johnson, Lanny L.; Rohrer, Michael D.; Walls, Robert C.; Bartels, Kenneth E.
1994-09-01
The effects of Ho:YAG laser energy on articular cartilage and subchondral bone adjacent to traumatically created cartilage lesions in a continuous weight-bearing model were investigated. The 2.1 micrometers wavelength was delivered in hand-controlled contact and near-contact hard tissue arthroscopic surgery in a saline medium. Bilateral arthroscopy was performed on normal antebrachiocarpal and intercarpal joints of four adult horses. One-hundred twenty traumatic lesions were created on three weight-bearing articular surfaces with a knife, curette, or a motorized burr. Depths of the lesions were partial and full thickness. Configurations of the lesions were lacerations, scrapes, and craters. Left limbs were used as controls. Right limb lesions were treated with various intensities of laser energy. Animals were sacrificed at intervals of 1, 3, and 8 weeks. Gross microscopic anatomy was documented, and tissue sections were subjected to blind review by a pathologist. Mankin grading for cellularity and proteoglycan content was used to qualitatively evaluate cartilage response. Cartilage adjacent to all lesions exposed to laser energy had better cellularity and proteoglycan content than corresponding controls by Mankin grading.
Investigation of relations between skin cancer lesions' images and their fluorescent spectra
NASA Astrophysics Data System (ADS)
Pavlova, P.; Borisova, E.; Avramov, L.; Petkova, El.; Troyanova, P.
2010-03-01
This investigation is based on images obtained from healthy tissue and skin cancer lesions and their fluorescent spectra of cutaneous lesions derived after optical stimulation. Our analyses show that the lesions’ spectra of are different of those, obtained from normal tissue and the differences depend on the type of cancer. We use a comparison between these “healthy” and “unhealthy” spectra to define forms of variations and corresponding diseases. However, the value of the emitted light varies not only between the patients, but also depending on the position of the tested area inside of one lesion. These variations could be result from two reasons: different degree of damaging and different thickness of the suspicious lesion area. Regarded to the visible image of the lesion, it could be connected with the chroma of colour of the tested area and the lesion homogeneity that corresponds to particular disease. For our investigation, images and spectra of three non-melanoma cutanous malignant tumors are investigated, namely—basal cell carcinoma, squamous cell carcinoma, and keratoacanthoma. The images were processed obtaining the chroma by elimination of the background—healthy tissue, and applying it as a basic signal for transformation from RGB to Lab colorimetric model. The chroma of the areas of emission is compared with the relative value of fluorescence spectra. Specific spectral features are used to develop hybrid diagnostic algorithm (including image and spectral features) for differentiation of these three kinds of malignant cutaneous pathologies.
Weinand, Christian; Peretti, Giuseppe M; Adams, Samuel B; Randolph, Mark A; Savvidis, Estafios; Gill, Thomas J
2006-11-01
Successful treatment of tears to the avascular region of the meniscus remains a challenge. Current repair techniques, such as sutures and anchors, are effective in stabilizing the peripheral, vascularized regions of the meniscus, but are not adequate for promoting healing in the avascular region. The purpose of this study was to demonstrate the healing ability of a tissue-engineered repair technique using allogenic chondrocytes from three different sources for the avascular zone of the meniscus. Articular, auricular, and costal chondrocytes were harvested from 3-month-old Yorkshire swine. A 1-cm bucket-handle lesion was created in the avascular zone of each three swine. A cell-scaffold construct, composed of a single chondrocyte cell type and Vicryl mesh, was implanted into the lesion and secured with two vertical mattress sutures. Controls consisted of each three sutured unseeded mesh implants, suture only, and untreated lesions. The swine were allowed immediate post-operative full weight bearing. Menisci and controls were harvested after 12 weeks. In all experimental samples, lesion closure was observed. Gross mechanical testing with two Adson forceps demonstrated bonding of the lesion. Histological analysis showed formation of new tissue in all three experimental samples. None of the control samples demonstrated closure and formation of new matrix. We present preliminary data that demonstrates the potential of a tissue-engineered, allogenic cellular repair to provide successful healing of lesions in the avascular zone in a large animal model.
Filler metal alloy for welding cast nickel aluminide alloys
Santella, Michael L.; Sikka, Vinod K.
1998-01-01
A filler metal alloy used as a filler for welding east nickel aluminide alloys contains from about 15 to about 17 wt. % chromium, from about 4 to about 5 wt. % aluminum, equal to or less than about 1.5 wt. % molybdenum, from about 1 to about 4.5 wt. % zirconium, equal to or less than about 0.01 wt. % yttrium, equal to or less than about 0.01 wt. % boron and the balance nickel. The filler metal alloy is made by melting and casting techniques such as are melting the components of the filler metal alloy and east in copper chill molds.
Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions
NASA Astrophysics Data System (ADS)
Robbins, Constance M.; Raghavan, Guruprasad; Antaki, James F.; Kainerstorfer, Jana M.
2017-12-01
In breast cancer diagnosis and therapy monitoring, there is a need for frequent, noninvasive disease progression evaluation. Breast tumors differ from healthy tissue in mechanical stiffness as well as optical properties, which allows optical methods to detect and monitor breast lesions noninvasively. Spatial frequency-domain imaging (SFDI) is a reflectance-based diffuse optical method that can yield two-dimensional images of absolute optical properties of tissue with an inexpensive and portable system, although depth penetration is limited. Since the absorption coefficient of breast tissue is relatively low and the tissue is quite flexible, there is an opportunity for compression of tissue to bring stiff, palpable breast lesions within the detection range of SFDI. Sixteen breast tissue-mimicking phantoms were fabricated containing stiffer, more highly absorbing tumor-mimicking inclusions of varying absorption contrast and depth. These phantoms were imaged with an SFDI system at five levels of compression. An increase in absorption contrast was observed with compression, and reliable detection of each inclusion was achieved when compression was sufficient to bring the inclusion center within ˜12 mm of the phantom surface. At highest compression level, contrasts achieved with this system were comparable to those measured with single source-detector near-infrared spectroscopy.
Intraosseous Hibernoma in the Sacrum of an Adult.
Westacott, Lorraine; Collins, Angus; Dickenson, Ian
2016-12-01
Hibernoma is an uncommon lipomatous tumor composed of brown adipose cells that until recently has only ever been described in soft tissue locations. This report describes the histological features of a discrete lesion in the sacrum of an 84-year-old lady. Biopsy of this lesion demonstrated that it consisted predominantly of multivacuolated lipocytes with a morphological and immunohistochemical profile consistent with brown fat cells. The lesion was diagnosed as an intraosseous hibernoma. This is the 16th report in the English literature of a hibernoma occurring outside of a soft tissue location. © The Author(s) 2016.
Clinical Recommendations on Carious Tissue Removal in Cavitated Lesions.
Schwendicke, Falk; Frencken, Jo; Innes, Nicola
2018-01-01
Non-cleansable carious lesions where sealing is no longer an option should be restored in the vast majority of cases. Prior to restoring the cavity, carious tissue removal is performed, mainly to increase the longevity of the restoration. Such removal, however, should not be conducted in a way that the vital pulp is harmed. This means that in teeth with shallow or moderately deep lesions, selective removal to firm dentine is recommended, while in deep lesions (radiographically extending into the pulpal third or quarter of the dentine) selective removal to soft dentine should be performed. In permanent teeth, stepwise removal is a possible alternative, while in primary teeth the Hall Technique can be considered too. To assess carious tissue removal, the hardness of the dentine should be the primary criterion. Moisture, colour, and additional parameters (like fluorescence of bacterial porphyrins, etc.) might be used, but should be critically evaluated towards their validity and patients' benefit. There is insufficient evidence to recommend a specific single carious tissue removal method. However, hand or chemomechanical excavation seem useful, as they reduce pain and discomfort during treatment. Current evidence also does not support any specific restoration material or (bonding) strategy for restoring cavities resulting from different carious tissue removal strategies. Prior to restoring the cavity, cavity disinfection is not recommended any longer. © 2018 S. Karger AG, Basel.
Endothelium Preserving Microwave Treatment for Atherosclerosis
NASA Technical Reports Server (NTRS)
Carl, James R. (Inventor); Arndt, G. Dickey (Inventor); Fink, Patrick W. (Inventor); Beer, N. Reginald (Inventor); Henry, Phillip D. (Inventor); Pacifico, Antonio (Inventor); Raffoul, George W. (Inventor)
2000-01-01
Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial laser and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C., within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable of focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and man be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.
Endothelium Preserving Microwave Treatment for Atherosclerosis
NASA Technical Reports Server (NTRS)
Carl, James R. (Inventor); Arndt, G. Dickey (Inventor); Fink, Patrick W. (Inventor); Beer, N. Reginald (Inventor); Henry, Phillip D. (Inventor); Pacifico, Antonio (Inventor); Raffoul, George W. (Inventor)
2001-01-01
Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.
Endothelium Preserving Microwave Treatment for Atherosclerois
NASA Technical Reports Server (NTRS)
Carl, James R. (Inventor); Arndt, G. Dickey (Inventor); Fink, Patrick W. (Inventor); Beer, N. Reginald (Inventor); Henry, Phillip D. (Inventor); Pacifico, Antonio (Inventor); Raffoul, George W. (Inventor)
2001-01-01
Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount about 20 C, with the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radical sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors of the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed beam. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.
Endothelium Preserving Microwave Treatment for Atherosclerosis
NASA Technical Reports Server (NTRS)
Carl, James R. (Inventor); Arndt, Dickey (Inventor); Fink, Patrick W. (Inventor); Beer, Reginald (Inventor); Henry, Phillip D. (Inventor); Pacifico, Antonio (Inventor); Raffoul, George W. (Inventor)
2002-01-01
Method and apparatus are provided to treat atherosclerosis wherein the artery is partially closed by dilating the artery while preserving the vital and sensitive endothelial layer thereof. Microwave energy having a frequency from 3 GHz to 300 GHz is propagated into the arterial wall to produce a desired temperature profile therein at tissue depths sufficient for thermally necrosing connective tissue and softening fatty and waxy plaque while limiting heating of surrounding tissues including the endothelial layer and/or other healthy tissue, organs, and blood. The heating period for raising the temperature a potentially desired amount, about 20 C. within the atherosclerotic lesion may be less than about one second. In one embodiment of the invention, a radically beveled waveguide antenna is used to deliver microwave energy at frequencies from 25 GHz or 30 GHz to about 300 GHz and is focused towards a particular radial sector of the artery. Because the atherosclerotic lesions are often asymmetrically disposed, directable or focussed heating preserves healthy sectors or the artery and applies energy to the asymmetrically positioned lesion faster than a non-directed bean. A computer simulation predicts isothermic temperature profiles for the given conditions and may be used in selecting power, pulse duration, beam width, and frequency of operation to maximize energy deposition and control heat rise within the atherosclerotic lesion without harming healthy tissues or the sensitive endothelium cells.
Functional remineralization of carious dentin
NASA Astrophysics Data System (ADS)
Pugach, Megan Kardon
A primary goal of dental tissue engineering is the biological reconstruction of tooth substrate destroyed by caries or other diseases affecting tooth mineralization. Traditionally, dentists treat caries by using invasive techniques to remove the diseased dental tissue and restore the lesion, ideally preventing further progression of decay. Success in strategies associated with remineralization of enamel and root caries have contributed to the less invasive prospect of remineralization of dentinal carious lesions. The central hypothesis of this dissertation is that carious dentin lesions can be remineralized if the lesions contain residual mineral. Caries Detector (CD) stained zones (pink, light pink, transparent and normal) of arrested carious dentin lesions were characterized according to microstructure by atomic force microscopy (AFM) imaging, mineral content by digital transverse microradiography, and nanomechanical properties by AFM-based nanoindentation. CD-stained and unstained zones had significantly different microstructure, mineral content and nanomechanical properties. Furthermore, the most demineralized carious zone contained residual mineral. To obtain reproducible, standardized dentin caries lesions, we characterized the lesions from an artificial carious dentin lesion model using a 0.05M acetate demineralization buffer. The artificial caries-like lesions produced by the buffer had similar mineral content and nanomechanical properties in the stained and unstained zones as natural dentin lesions. Both natural and artificial lesions had significant correlations between mineral content and nanomechanical properties. Mineral crystallite size and shape was examined by small angle x-ray scattering. Both natural and artificial carious dentin had different mineral sizes than normal dentin. Collagen in natural and artificial carious dentin lesions was examined by trichrome stain, AFM high-resolution imaging, and UV resonance Raman spectroscopy, to determine if fibrils were intact and mineralization levels. It appeared that the collagen in the most demineralized pink zones of the lesions was intact and contained intrafibrillar mineral. Natural and artificial carious dentin lesions were treated with remineralization solutions containing different amounts of Ca2+ and PO 43-, with and without CO32- and with and without 2 ppm fluoride. The hydrated nanomechanical properties of the lesions were partially restored. This suggests that the most CD-stained zones of arrested dentin caries lesions may be remineralizable. These results suggest that remineralization as an approach of minimally invasive dentistry using non-invasive treatments to restore dental tissues is possible.
Imaging feedback of histotripsy treatments using ultrasound shear wave elastography.
Wang, Tzu-Yin; Hall, Timothy L; Xu, Zhen; Fowlkes, J Brian; Cain, Charles A
2012-06-01
Histotripsy is a cavitation-based ultrasound therapy that mechanically fractionates soft solid tissues into fluid-like homogenates. This paper investigates the feasibility of imaging the tissue elasticity change during the histotripsy process as a tool to provide feedback for the treatments. The treatments were performed on agar tissue phantoms and ex vivo kidneys using 3-cycle ultrasound pulses delivered by a 750-kHz therapeutic array at peak negative/positive pressure of 17/108 MPa and a repetition rate of 50 Hz. Lesions with different degrees of damage were created with increasing numbers of therapy pulses from 0 to 2000 pulses per treatment location. The elasticity of the lesions was measured with ultrasound shear wave elastography, in which a quasi-planar shear wave was induced by acoustic radiation force generated by the therapeutic array, and tracked with ultrasound imaging at 3000 frames per second. Based on the shear wave velocity calculated from the sequentially captured frames, the Young's modulus was reconstructed. Results showed that the lesions were more easily identified on the shear wave velocity images than on B-mode images. As the number of therapy pulses increased from 0 to 2000 pulses/location, the Young's modulus decreased exponentially from 22.1 ± 2.7 to 2.1 ± 1.1 kPa in the tissue phantoms (R2 = 0.99, N = 9 each), and from 33.0 ± 7.1 to 4.0 ± 2.5 kPa in the ex vivo kidneys (R2 = 0.99, N = 8 each). Correspondingly, the tissues transformed from completely intact to completely fractionated as examined via histology. A good correlation existed between the lesions' Young's modulus and the degree of tissue fractionation as examined with the percentage of remaining structurally intact cell nuclei (R2 = 0.91, N = 8 each). These results indicate that lesions produced by histotripsy can be detected with high sensitivity using shear wave elastography. Because the decrease in the tissue elasticity corresponded well with the morphological and histological change, this study provides a basis for predicting the local treatment outcomes from tissue elasticity change.
Inverted papillomas and benign nonneoplastic lesions of the nasal cavity
Casiano, Roy R.
2012-01-01
Background: Benign lesions of the nasal cavity represent a diverse group of pathologies. Furthermore, each of these disorders may present differently in any given patient as pain and discomfort, epistaxis, headaches, vision changes, or nasal obstruction. Although these nasal masses are benign, many of them have a significant capacity for local tissue destruction and symptomatology secondary to this destruction. Advances in office-based endoscopic nasendoscopy have equipped the otolaryngologist with a safe, inexpensive, and rapid means of directly visualizing lesions within the nasal cavity and the initiation of appropriate treatment. Methods: The purpose of this study is to review the diagnosis, management, and controversies of many of the most common benign lesions of the nasal cavity encountered by the primary care physician or otolaryngologist. Results: This includes discussion of inverted papilloma (IP), juvenile angiofibroma, squamous papilloma, pyogenic granuloma, hereditary hemorrhagic telangiectasia, schwannoma, benign fibro-osseous lesions, and other benign lesions of the nasal cavity, with particular emphasis on IP and juvenile angiofibroma. Conclusion: A diverse array of benign lesions occur within the nasal cavity and paranasal cavities. Despite their inability to metastasize, many of these lesions have significant capability for local tissue destruction and recurrence. PMID:22487294
Li, Xing; Zhao, Yayun; Bing, Yue; Li, Yaping; Gan, Ning; Guo, Zhiyong; Peng, Zhaoxiang; Zhu, Yabin
2013-06-26
The macroporous materials were prepared from the transformation of cuttlebone as biotemplates under hydrothermal reactions and characterized by Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), thermogravimetric/differential thermal analyses (TG-DTA), and scanning electron microscopy (SEM). Cell experimental results showed that the prepared materials as bone tissue engineering scaffolds or fillers had fine biocompatibility suitable for adhesion and proliferation of the hMSCs (human marrow mesenchymal stem cells). Histological analyses were carried out by implanting the scaffolds into a rabbit femur, where the bioresorption, degradation, and biological activity of the scaffolds were observed in the animal body. The prepared scaffolds kept the original three-dimensional frameworks with the ordered porous structures, which made for blood circulation, nutrition supply, and the cells implantation. The biotemplated syntheses could provide a new effective approach to prepare the bone tissue engineering scaffold materials.
Injectable Hydrogel Scaffold from Decellularized Human Lipoaspirate
Young, D. Adam; Ibrahim, Dina O.; Hu, Diane; Christman, Karen L.
2010-01-01
Soft tissue fillers are rapidly gaining popularity for aesthetic improvements or repair of adipose tissue deficits. Several injectable biopolymers have been investigated for this purpose but often face rapid resorption or limited adipogenesis, and do not mimic the native adipose extracellular matrix (ECM). We have generated an injectable adipose matrix scaffold by efficiently removing both the cellular and lipid contents of human lipoaspirate. The decellularized material retained a complex composition of peptides and glycosaminoglycans found in native adipose ECM. This matrix can be further processed by solubilizing the extracted ECM to generate a thermally-responsive hydrogel that self-assembles upon subcutaneous injection. This hydrogel also supports the growth and survival of patient matched adipose - derived stem cells in vitro. The development of an injectable hydrogel from human lipoaspirate represents a minimally-invasive option for adipose tissue engineering in terms of both the collection of source material and delivery of the scaffold. PMID:20932943
Machado-Santos, Joana; Saji, Etsuji; Tröscher, Anna R; Paunovic, Manuela; Liblau, Roland; Gabriely, Galina; Bien, Christian G; Bauer, Jan; Lassmann, Hans
2018-06-04
Multiple sclerosis is an inflammatory demyelinating disease in which active demyelination and neurodegeneration are associated with lymphocyte infiltrates in the brain. However, so far little is known regarding the phenotype and function of these infiltrating lymphocyte populations. In this study, we performed an in-depth phenotypic characterization of T and B cell infiltrates in a large set of multiple sclerosis cases with different disease and lesion stages and compared the findings with those seen in inflammatory, non-inflammatory and normal human controls. In multiple sclerosis lesions, we found a dominance of CD8+ T cells and a prominent contribution of CD20+ B cells in all disease courses and lesion stages, including acute multiple sclerosis cases with very short disease duration, while CD4+ T cells were sparse. A dominance of CD8+ T cells was also seen in other inflammatory controls, such as Rasmussen's encephalitis and viral encephalitis, but the contribution of B cells in these diseases was modest. Phenotypic analysis of the CD8+ T cells suggested that part of the infiltrating cells in active lesions proliferate, show an activated cytotoxic phenotype and are in part destroyed by apoptosis. Further characterization of the remaining cells suggest that CD8+ T cells acquire features of tissue-resident memory cells, which may be focally reactivated in active lesions of acute, relapsing and progressive multiple sclerosis, while B cells, at least in part, gradually transform into plasma cells. The loss of surface molecules involved in the egress of leucocytes from inflamed tissue, such as S1P1 or CCR7, and the upregulation of CD103 expression may be responsible for the compartmentalization of the inflammatory response in established lesions. Similar phenotypic changes of tissue-infiltrating CD8+ T cells were also seen in Rasmussen's encephalitis. Our data underline the potential importance of CD8+ T lymphocytes and B cells in the inflammatory response in established multiple sclerosis lesions. Tissue-resident T and B cells may represent guardians of previous inflammatory brain disease, which can be reactivated and sustain the inflammatory response, when they are re-exposed to their specific antigen.
Wetting and spreading behavior of molten brazing filler metallic alloys on metallic substrate
NASA Astrophysics Data System (ADS)
Kogi, Satoshi; Kajiura, Tetsurou; Hanada, Yukiakira; Miyazawa, Yasuyuki
2014-08-01
Wetting and spreading of molten brazing filler material are important factors that influence the brazing ability of a joint to be brazed. Several investigations into the wetting ability of a brazing filler alloy and its surface tension in molten state, in addition to effects of brazing time and temperature on the contact angle, have been carried out. In general, dissimilar-metals brazing technology and high-performance brazed joint are necessities for the manufacturing field in the near future. Therefore, to address this requirement, more such studies on wetting and spreading of filler material are required for a deeper understanding. Generally, surface roughness and surface conditions affect spreading of molten brazing filler material during brazing. Wetting by and interfacial reactions of the molten brazing filler material with the metallic substrate, especially, affect strongly the spreading of the filler material. In this study, the effects of surface roughness and surface conditions on the spreading of molten brazing filler metallic alloys were investigated. Ag-(40-x)Cu-xIn and Ag- (40-x)Cu-xSn (x=5, 10, 15, 20, 25) alloys were used as brazing filler materials. A mild-steel square plate (S45C (JIS); side: 30 mm; thickness: 3mm) was employed as the substrate. A few surfaces with varying roughness were prepared using emery paper. Brazing filler material and metallic base plate were first washed with acetone, and then a flux was applied to them. The filler, 50 mg, was placed on the center of the metallic base with the flux. A spreading test was performed under Ar gas using an electrically heated furnace, after which, the original spreading area, defined as the sessile drop area, and the apparent spreading area, produced by the capillary grooves, were both evaluated. It was observed that the spreading area decreased with increasing In and Sn content.
The pathology of americium 241.
Nilsson, A; Broomé-Karlsson, A
1976-02-01
Male CBA-mice were injected intraperitoneally with different doses of 241Am-citrate (16, 8, 0.4, 0.2, 0.04 muCi/kg). The two highest doses were highly destructive of the haematopoietic tissues, testes and bone tissue. The highest frequency of induced tumours of the skeleton and haematopoietic tissue was found in the 8 muCi group. In the liver, adrenal glands, kidney and heart degenerative lesions were found mainly in the higher dose groups. In the lower dose groups degenerative lesions seemed to appear earlier and at a higher frequency than in the control group.
Curtis, Andrew R; Palin, William M; Fleming, Garry J P; Shortall, Adrian C C; Marquis, Peter M
2009-02-01
To assess the mechanical properties of discrete filler particles representative of several inorganic fillers in modern dental resin-based composites (RBCs) and to assess the validity of a novel micromanipulation technique. RBCs with microhybrid (Filtek Z250), 'nanohybrid' (Grandio) and 'nanofilled' (Filtek Supreme), filler particle morphologies were investigated. Filler particles were provided by the manufacturer or separated from the unpolymerized resin using a dissolution technique. Filler particles (n=30) were subjected to compression using a micromanipulation technique between a descending glass probe and a glass slide. The number of distinct fractures particles underwent was determined from force/displacement and stress/deformation curves and the force at fracture and pseudo-modulus of stress was calculated. Agglomerated fillers ('nanoclusters') exhibited up to four distinct fractures, while spheroidal and irregular particles underwent either a single fracture or did not fracture following micromanipulation. Z-tests highlighted failure of nanoclusters to be significant compared with spheroidal and irregular particles (P<0.05). The mean force at first fracture of the nanoclusters was greater (1702+/-909 microN) than spheroidal and irregular particles (1389+/-1342 and 1356+/-1093 microN, respectively). Likewise, the initial pseudo-modulus of stress of nanoclusters (797+/-555 MPa) was also greater than spheroidal (587+/-439 MPa) or irregular (552+/-275 MPa) fillers. The validity of employing the micromanipulation technique to determine the mechanical properties of filler particulates was established. The 'nanoclusters' exhibited a greater tendency to multiple fractures compared with conventional fillers and possessed a comparatively higher variability of pseudo-modulus and load prior to and at fracture, which may modify the damage tolerance of the overall RBC system.
NASA Astrophysics Data System (ADS)
Mustapa, S. A. S.; Ramli Sulong, N. H.
2017-06-01
This research deals with contribution of hybrid fillers with palm oil clinker (POC) as a novel bio-filler in solvent-borne intumescent fire protective coating for steel. The hybrid fillers with POC were mixed in appropriate amount of additives and acrylic binder to produce the intumescent coatings. The intumescent coatings were characterized by using Bunsen burner test, surface spread of flame, thermogravimetric analysis, field emission scanning electron microscopy, static immersion and Instron micro tester equipment. Specimen with POC as a single filler has significantly enhanced the fire protection performances of the intumescent coating due to the high thermal stability of POC, where less than 10% of temperature different when compared to specimens with hybrid fillers. From the flame spread classification, class 1 is the best classification while Class 4 is the worst and considered high risk. All specimens was classified as class 1 since the final spread of flame was less than 165 mm. For hybrid fillers composition, specimen consist of POC/Al(OH)3/TiO2 has significantly improved the water resistance of the coating due to the low solubility of Al(OH)3 in water, while specimen contain of Mg(OH)2 had higher mechanical strength due to the strong bonding between the metal surface and acrylic binder/Mg(OH)2 filler. It was found that coating with the incorporation of all hybrid fillers gives excellent fire protection performance with good thermal stability, water resistance and mechanical properties. It can be concluded that, the selection of appropriate composition of fillers and binder in intumescent coating was highly influence the intumescent coating performance.
Park, Sunyoung; Park, Kui Young; Yeo, In Kwon; Cho, Sung Yeon; Ah, Young Chang; Koh, Hyun Ju; Park, Won Seok; Kim, Beom Joon
2014-06-01
A variety of hyaluronic acid (HA) fillers demonstrate unique physical characteristics, which affect the quality of the HA filler products. The critical factors that affect the degradation of HA gels have not yet been determined. Our objective was to determine the characteristics of HA gels that affect their resistance to the degradation caused by radicals and enzymes. Three types of HA fillers for repairing deep wrinkles, Juvederm Ultra Plus (J-U), Restylane Perlane (Perlane), and Cleviel, were tested in this study. The resistance of these HA fillers to enzymatic degradation was measured by carbazole and displacement assays using hyaluronidase as the enzyme. The resistance of these fillers to radical degradation was measured by the displacement assay using H2O2. Different tests for evaluating the degradation resistance of HA gels can yield different results. The filler most susceptible to enzymatic degradation was J-U, followed by Perlane and Cleviel. The HA filler showing the highest degree of degradation caused by H2O2 treatment was Perlane, followed by J-U, and then Cleviel. Cleviel showed higher enzymatic and radical resistances than J-U and Perlane did. Furthermore, it exhibited the highest resistance to heat and the lowest swelling ratio among all the fillers that were examined. The main factor determining the degradation of HA particles is the gel swelling ratio, which is related to the particle structure of the gel. Our in vitro assays suggest that the decrease in the swelling ratio will lead to a retarding effect on the degradation of HA fillers.
NASA Astrophysics Data System (ADS)
Tahir, Abdullah Mohd; Lair, Noor Ajian Mohd; Wei, Foo Jun
2018-05-01
The Shielded Metal Arc Welding (SMAW) is (or the Stick welding) defined as a welding process, which melts and joins metals with an arc between a welding filler (electrode rod) and the workpieces. The main objective was to study the mechanical properties of welded metal under different types of welding fillers and current for SMAW. This project utilized the Design of Experiment (DOE) by adopting the Full Factorial Design. The independent variables were the types of welding filler and welding current, whereas the other welding parameters were fixed at the optimum value. The levels for types of welding filler were by the models of welding filler (E6013, E7016 and E7018) used and the levels for welding current were 80A and 90A. The responses were the mechanical properties of welded material, which include tensile strength and hardness. The experiment was analyzed using the two way ANOVA. The results prove that there are significant effects of welding filler types and current levels on the tensile strength and hardness of the welded metal. At the same time, the ANOVA results and interaction plot indicate that there are significant interactions between the welding filler types and the welding current on both the hardness and tensile strength of the welded metals, which has never been reported before. This project found that when the amount of heat input with increase, the mechanical properties such as tensile strength and hardness decrease. The optimum tensile strength for welded metal is produced by the welding filler E7016 and the optimum of hardness of welded metal is produced by the welding filler E7018 at welding current of 80A.
NASA Astrophysics Data System (ADS)
Harahap, Hamidah; Lubis, Yuni Aldriani; Taslim, Iriany, Nasution, Halimatuddahliana; Agustini, Hamda Eka
2018-04-01
A study has been conducted on the effect of filler loading on NRL films filled with NCC from corn cob waste. This study reviews on the filler loading of NRL film characteristics. The process begins with the production of NCC filler and then proceed with the production NRL film which is processed by coagulant dipping method. NRL is filled with NCC and PVP as dispersion agent of 2, 4, 3, 8 grams (filler loading) and 1% PVP by weight. The production of NRL film started with pre-vulcanization process at 70 °C and followed by vulcanization process at 110 °C for 20 minutes. The results showed that higher filler loading improved the higher crosslink density and mechanical properties of NRL film.
NASA Astrophysics Data System (ADS)
Ray, Sudip; Bhowmick, Anil K.; Sarma, K. S. S.; Majali, A. B.; Tikku, V. K.
2002-12-01
A novel process of surface modification of clay filler has been developed by coating this with an acrylate monomer, trimethylol propane triacrylate (TMPTA) or a silane coupling agent, triethoxy vinyl silane (TEVS) followed by electron beam irradiation. Characterization of these surface modified fillers has been carried out by Fourier-transform infrared analysis (FTIR), electron spectroscopy for chemical analysis (ESCA), wettability by dynamic wicking method measuring the rise of a liquid through a filler-packed capillary tube and water flotation test, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). Presence of the acrylate and the silane coupling agent on the modified fillers has been confirmed from FTIR, ESCA, and EDX studies, which has also been supported by TGA studies. The contact angle measurement by dynamic wicking method suggests improvement in hydrophobicity of the treated fillers, which is supported by water flotation test especially in the case of silanized clay. However, XRD studies demonstrate that the entire modification process does not affect the bulk properties of the fillers. Finally, both unmodified and modified clay fillers have been incorporated in styrene butadiene rubber (SBR) and nitrile rubber (NBR). Rheometric and mechanical properties reveal that there is a definite improvement using these modified fillers specially in the case of silanized clay compared to the control sample, probably due to successful enhancement in interaction between the treated clay and the base polymer.
The Morel-Lavallée lesion revisited: management in spinopelvic dissociation.
Dodwad, Shah Nawaz M; Niedermeier, Steven R; Yu, Elizabeth; Ferguson, Tania A; Klineberg, Eric O; Khan, Safdar N
2015-06-01
The Morel-Lavallée lesion occurs from a compression and shear force that usually separates the skin and subcutaneous tissue from the underlying muscular fascia. A dead space is created that becomes filled with blood, liquefied fat, and lymphatic fluid from the shearing of vasculature and lymphatics. If not treated appropriately, these lesions can become infected, cause tissue necrosis, or form chronic seromas. To review appropriate identification and treatment of Morel-Lavallée lesions in spinopelvic dissociation patients. Uncontrolled case series. Retrospective review of medical records. No funding was received in support of this study. The authors report no conflicts of interest. We present four cases of patients with traumatic spinopelvic dissociation. All had concomitant lumbosacral Morel-Lavallée lesions. All four trauma patients suffered traumatic spinopelvic dissociation with concomitant lumbosacral Morel-Lavallée lesions. Appropriate treatment included irrigation and debridement, drainage, antibiotics, and vacuum-assisted wound closure. Our series reflects an association of Morel-Lavallée lesion in spinopelvic dissociation trauma patients. Possibly, the rotatory injury that occurs at the spinopelvic junction creates a shear force to form the Morel-Lavallée lesion. When presented with a spinopelvic dissociation patient, one should be prepared to treat a Morel-Lavallée lesion. Copyright © 2015 Elsevier Inc. All rights reserved.
Nd:YAG and CO2 laser therapy of oral mucosal lesions.
White, J M; Chaudhry, S I; Kudler, J J; Sekandari, N; Schoelch, M L; Silverman, S
1998-12-01
Experiences gained in the management of oral mucosal lesions by CO2 and Nd:YAG laser therapy in an outpatient clinic treated over an 80-year period are described. Lasers have indications for use in dentistry for incision, excision, and coagulation of intraoral soft tissue. Advances in laser technology have provided delivery systems for site-specific delivery of laser energy with short interaction items on tissue to be ablated. This study retrospectively evaluates a series of clinical case studies. Sixty-four patients with a variety of benign oral soft tissue lesions were treated by laser excision. Thirty-five patients were treated by a pulsed fiberoptic delivered Nd:YAG contact laser, and 29 by a continuous free-beam CO2 non-contact laser. The largest group of lesions treated were leukoplakia (39 cases). Other lesions excised and biopsied were lichen planus, squamous papilloma, pyogenic granuloma, focal melanosis, nonhealing traumatic ulceration, hemangioma, and lymphangioma. All patients were followed postoperatively (mean 6.8 months, range 1-36 months). Laser excision was well tolerated by patients with no intraoperative or postoperative adverse effects. All patients healed postsurgically with no loss of function. CO2 and Nd:YAG lasers are successful surgical options when performing excision of benign intraoral lesions. Advantages of laser therapy include minimal postoperative pain, conservative site-specific minimally invasive surgeries, and elimination of need for sutures.
2015-01-01
Endometrial polyps and submucosal fibroids are common causes of abnormal uterine bleeding (AUB) and less commonly infertility. The prevalence of such intrauterine lesions increases with age during the reproductive years, and usually decreases after menopause. The first-line imaging examination in the diagnosis of endometrial polyps as well as submucosal fibroidsis ultrasound, but its accuracy is not obvious. Elastography is an ultrasound-based imaging modality that is used to assess the stiffness of examined tissues. Considering the fact that endometrial polyps derive from soft endometrial tissue and submucosal fibroids are made of hard muscle tissue, elastography seems a perfect tool to differentiate between such lesions. I present two groups of patients with AUB and intrauterine lesions suspected on ultrasound. In the first group of patients, elastography showed that the stiffness of the lesion was similar to the endometrium and softer than the myometrium. During hysteroscopies endometrial polyps were removed. In the second group of patients, elastography showed that the stiffness of the lesion was similar to the myometrium and harder than the endometrium. During hysteroscopies submucosal fibroids were removed. In both groups, the diagnosis was confirmed by the pathological examination in all cases. It was demonstrated that with the use of elastography it is possible to assess the stiffness of intrauterine lesions, which may be useful in differentiating between endometrial polyps and submucosal fibroids. PMID:26327901
Woźniak, Sławomir
2015-06-01
Endometrial polyps and submucosal fibroids are common causes of abnormal uterine bleeding (AUB) and less commonly infertility. The prevalence of such intrauterine lesions increases with age during the reproductive years, and usually decreases after menopause. The first-line imaging examination in the diagnosis of endometrial polyps as well as submucosal fibroidsis ultrasound, but its accuracy is not obvious. Elastography is an ultrasound-based imaging modality that is used to assess the stiffness of examined tissues. Considering the fact that endometrial polyps derive from soft endometrial tissue and submucosal fibroids are made of hard muscle tissue, elastography seems a perfect tool to differentiate between such lesions. I present two groups of patients with AUB and intrauterine lesions suspected on ultrasound. In the first group of patients, elastography showed that the stiffness of the lesion was similar to the endometrium and softer than the myometrium. During hysteroscopies endometrial polyps were removed. In the second group of patients, elastography showed that the stiffness of the lesion was similar to the myometrium and harder than the endometrium. During hysteroscopies submucosal fibroids were removed. In both groups, the diagnosis was confirmed by the pathological examination in all cases. It was demonstrated that with the use of elastography it is possible to assess the stiffness of intrauterine lesions, which may be useful in differentiating between endometrial polyps and submucosal fibroids.
Initial Experience with the Extracorporeal HIFU Knife with 49 Patients: Japanese Experience
NASA Astrophysics Data System (ADS)
Ganaha, F.; Okuno, T.; Lee, C. O.; Shimizu, T.; Osako, K.; Oka, S.; Lee, K. H.; Chen, W. Z.; Zhu, H.; Park, S. H.; Qi, Z.; Shi, D.; Song, H. S.
2005-03-01
Forty nine patients with 63 tumours were treated with the Chongqing Haifu knife, as an adjunct to intra-arterial chemoinfusion. Treatment targets included breast (20 lesions), liver (16), bone (8), lymph-node (6), soft tissue (4), lung and pleura (4), pancreas (2), kidney (2) and adrenal gland (1). Follow-up contrast MRI was performed at 3 weeks to assess the effects of HIFU ablation. All cases completed the planned treatment. Of 25 lesions treated with the intention of complete tumour ablation, complete necrosis was obtained in 19 lesions (76%) including 4 secondary success cases. Among 32 lesions having partial and palliative treatment, tumour size was decreased in 6 lesions (21%), and good pain control was obtained in 6 out of 7 patients (86%). Skin injury was the most common complication after HIFU (16%), and was mostly a superficial dermal burn that did not necessitate any treatment. However, there was one patient with deep skin injury at an operation scar which resulted in skin perforation. Other adverse events included soft tissue swelling, prolonged fever, anorexia, persistent pain, shortness of the breath, sacroiliac joint fracture and prolonged diarrhoea. In our limited experience, superficial lesions (e.g. breast cancer, bone, soft tissue, lymph-node and pleural metastasis) appear to be good candidates for HIFU treatment. There appears to be a role for the HIFU knife in pain control for patients with bone metastasis and pancreatic cancer.
Xing, Xiaohua; Huang, Yao; Wang, Sen; Chi, Minhui; Zeng, Yongyi; Chen, Lihong; Li, Ling; Zeng, Jinhua; Lin, Minjie; Han, Xiao; Liu, Xiaolong; Liu, Jingfeng
2015-10-14
In clinical practices, the therapeutic outcomes and prognosis of hepatocellular carcinoma (HCC) patients with different tumor numbers after surgery are very different; however, the underlying mechanisms of the tumorigenesis and development of HCC with different tumor numbers are still not well understood. Here, we systematically compared the overall proteome profiles between the primary HCC with single and multiple lesions using iTRAQ-based quantitative proteomics approach. We identified that 107 and 330 proteins were dysregulated in HCC tissue with multiple lesions (MC group) and HCC tissue with a single lesion (SC group), compared with their non-cancerous tissue (MN and SN groups) respectively. The dysregulated proteins in MC group are concentrated in UBC signaling pathway and NFκB signaling pathway, but the dysregulated proteins in SC group are more concentrated in ERK signaling pathway and the NFκB signaling pathway. These information revealed that there might be different molecular mechanisms of the tumorigenesis and development of the HCC with single and multiple lesions. Furthermore, HSD17B13 were only down-regulated in MC group while HK2 were only up-regulated in SC group among these dysregulated proteins. Therefore, the protein HSD17B13 and HK2 might be potential biomarkers for the primary HCC with single and multiple lesions. Copyright © 2015 Elsevier B.V. All rights reserved.
Environmental conditions influence tissue regeneration rates in scleractinian corals.
Sabine, Alexis M; Smith, Tyler B; Williams, Dana E; Brandt, Marilyn E
2015-06-15
Natural and anthropogenic factors may influence corals' ability to recover from partial mortality. To examine how environmental conditions affect lesion healing, we assessed several water quality parameters and tissue regeneration rates in corals at six reefs around St. Thomas, US Virgin Islands. We hypothesized that sites closer to developed areas would have poor water quality due to proximity to anthropogenic stresses, which would impede tissue regeneration. We found that water flow and turbidity most strongly influenced lesion recovery rates. The most impacted site, with high turbidity and low flow, recovered almost three times slower than the least impacted site, with low turbidity, high flow, and low levels of anthropogenic disturbance. Our results illustrate that in addition to lesion-specific factors known to affect tissue regeneration, environmental conditions can also control corals' healing rates. Resource managers can use this information to protect low-flow, turbid nearshore reefs by minimizing sources of anthropogenic stress. Copyright © 2015 Elsevier Ltd. All rights reserved.
Walczak, Brian E; Johnson, Christopher N; Howe, B Matthew
2015-10-01
Myositis ossificans is a self-limiting, benign ossifying lesion that can affect any type of soft tissue, including subcutaneous fat, tendons, and nerves. It is most commonly found in muscle as a solitary lesion. Ossifying soft-tissue lesions historically have been inconsistently classified. Fundamentally, myositis ossificans can be categorized into nonhereditary and hereditary types, with the latter being a distinct entity with a separate pathophysiology and treatment approach. The etiology of myositis ossificans is variable; however, clinical presentation generally is characterized by an ossifying soft-tissue mass. Advanced cross-sectional imaging alone can be nonspecific and may appear to be similar to more sinister etiologies. Therefore, the evaluation of a suspicious soft-tissue mass often necessitates multiple imaging modalities for accurate diagnosis. When imaging is indeterminate, biopsy may be required for a histologic diagnosis. However, histopathology varies based on stage of evolution. The treatment of myositis ossificans is complex and is often made in a multidisciplinary fashion because accurate diagnosis is fundamental to a successful outcome. Copyright 2015 by the American Academy of Orthopaedic Surgeons.
Legan, Mateja; Tevžič, Spela; Tolar, Ana; Luzar, Boštjan; Marolt, Vera Ferlan
2011-03-01
GLUT-1 is a transmembrane glucose transport protein that allows the facilitated transport of glucose into cells, normally expressed in tissues which depend mainly on glucose metabolism. Enhanced expression of GLUT-1 can also be found in a large spectrum of carcinomas. This study aimed to investigate GLUT-1 expression in gallbladder tissue: from normal tissue samples, hyperplasias, low-grade and high-grade dysplasias to gallbladder carcinomas. In all, 115 archived samples of gallbladder tissue from 68 patients, presented after cholecystectomy, were immunohistochemically stained for GLUT-1. According to the intensity of GLUT-1 immunoreactivity, samples were divided into negative (stained 0-10% of cells stained), positive with weak to moderate (10-50%) and positive with strong (>50%) GLUT-1 expression. The GLUT-1 immunoreactivity of the samples showed a characteristic increase from premalignant lesions to carcinomas. Normal gallbladder tissue samples did not express GLUT-1 (100%). Weak expression was shown only focally in hyperplasias, but to a greater extent with low-grade dysplasias (20%), high-grade dysplasias (40%) and carcinomas (51.8%). Normal gallbladder tissue is GLUT-1 negative. GLUT-1 expression in carcinoma tissue is significantly higher than in dysplastic lesions. Strong GLUT-1 expression indicates 100% specificity for detecting gallbladder carcinomas. Therefore, GLUT-1 is a candidate as a diagnostic as well as a tissue prognostic marker in gallbladder carcinoma patients.
NASA Astrophysics Data System (ADS)
Zykova, A. K.; Pantyukhov, P. V.; Monakhova, T. V.; Popov, A. A.
2017-06-01
This article is focused on thermal oxidative degradation and biodegradation in soil of biocomposites based on ethylene-octene copolymer (EOC), filled by wood flour (from 30 to 70% wt.), in dependence to the filler content. The study of oxidative degradation of composites was carried out at two temperatures (80 and 130°C respectively). The induction period and the rates of oxidation were determined. It was concluded that as filler content raises, the induction period increases. It can be explained by the higher specific area of composites in comparison with pure EOC. However, high filled composites (60 and 70 % of the filler) are oxidized with a huge induction period because polyphenols in the filler inhibit the oxidation process. Biodegradation test under laboratory conditions was carried out to investigate the biodegradability of the material. Composites with lower filler content have lower weight loss rate. Small particles are capsulated by polymer and are isolated from moisture and microorganisms. On the other hand, at a high filling of the composite small particles stick together and act as large ones. Such filler agglomerates are connected with each other and allow microorganisms to penetrate into the composite. It was concluded as filler content raises the mass loss increases.
NASA Astrophysics Data System (ADS)
Mu, Mulan; Wan, Chaoying; McNally, Tony
2017-12-01
The outstanding thermal conductivity (λ) of graphene and its derivatives offers a potential route to enhance the thermal conductivity of epoxy resins. Key challenges still need to be overcome to ensure effective dispersion and distribution of 2D graphitic fillers throughout the epoxy matrix. 2D filler type, morphology, surface chemistry and dimensions are all important factors in determining filler thermal conductivity and de facto the thermal conductivity of the composite material. To achieve significant enhancement in the thermal conductivity of epoxy composites, different strategies are required to minimise phonon scattering at the interface between the nano-filler and epoxy matrix, including chemical functionalisation of the filler surfaces such that interactions between filler and matrix are promoted and interfacial thermal resistance (ITR) reduced. The combination of graphitic fillers with dimensions on different length scales can potentially form an interconnected multi-dimensional filler network and, thus contribute to enhanced thermal conduction. In this review, we describe the relevant properties of different 2D nano-structured graphitic materials and the factors which determine the translation of the intrinsic thermal conductivity of these 2D materials to epoxy resins. The key challenges and perspectives with regard achieving epoxy composites with significantly enhanced thermal conductivity on addition of 2D graphitic materials are presented.
Zhao, Ru-Jin; Gong, Li-Ying; Zhu, Hai-Dong; Liu, Qiao; Xu, Li-Xia; Lu, Lu; Yang, Qi-Zhi
2018-06-01
The present work investigates the properties of self-made magnetic filler from plastic waste bottle and explores a new technology approach of waste plastic resource utilization. The magnetic filler was prepared by air plasma modification and loading magnetic ferrite on the plastic strip from waste plastic bottle. The surface properties of magnetic filler were characterized by Atomic Force Microscope (AFM), contact angle system and Fourier Transform Infrared (FTIR). AFM images of original and modified plastic strip showed that low-temperature plasma treatment markedly increased the surface roughness of plastic strip. The mean roughness (Ra) of plastic strip rose from 1.116 to 5.024 nm. FTIR spectra indicated that a lot of polar oxygenic groups were introduced onto the surface of plastic by plasma modification. Modification by low-temperature plasma increased the hydrophilicity of plastic strip surface. When treatment time is 40 s, water contact angle of plastic strip surface reduced from 78.2° of original plastic strip to 25.3°. When used in bioreactor, magnetic filler had very favorable microenvironment for microorganism growth. Magnetic filler was more efficient for removing chemical oxygen demand (COD) and [Formula: see text] in sewage than nonmagnetic filler. The resource utilization of plastic wastes will become reality if the magnetic filler is applied widely.
Zhou, Yongcun; Yao, Yagang; Chen, Chia-Yun; Moon, Kyoungsik; Wang, Hong; Wong, Ching-ping
2014-01-01
Polymer modified fillers in composites has attracted the attention of numerous researchers. These fillers are composed of core-shell structures that exhibit enhanced physical and chemical properties that are associated with shell surface control and encapsulated core materials. In this study, we have described an apt method to prepare polyimide (PI)-modified aluminum nitride (AlN) fillers, AlN@PI. These fillers are used for electronic encapsulation in high performance polymer composites. Compared with that of untreated AlN composite, these AlN@PI/epoxy composites exhibit better thermal and dielectric properties. At 40 wt% of filler loading, the highest thermal conductivity of AlN@PI/epoxy composite reached 2.03 W/mK. In this way, the thermal conductivity is approximately enhanced by 10.6 times than that of the used epoxy matrix. The experimental results exhibiting the thermal conductivity of AlN@PI/epoxy composites were in good agreement with the values calculated from the parallel conduction model. This research work describes an effective pathway that modifies the surface of fillers with polymer coating. Furthermore, this novel technique improves the thermal and dielectric properties of fillers and these can be used extensively for electronic packaging applications. PMID:24759082
NASA Technical Reports Server (NTRS)
Mullaly, J. R.; Schmid, T. E.; Hecht, R. J.
1974-01-01
Filler materials proposed for use in the sputter fabrication regeneratively cooled thrust chambers were evaluated. Low melting castable alloys, CERROBEND. CERROCAST, and CERROTRU, slurry applied SERMETEL 481 and flame-sprayed aluminum were investigated as filler materials. Sputter deposition from a cylindrical cathode inverted magnestron was used to apply an OFHC copper closeout layer to filled OFHC copper ribbed-wall cylindrical substrates. The sputtered closeout layer structure was evaluated with respect to filler material contamination, predeposition machining and finishing operations, and deposition parameters. The application of aluminum by flame-spraying resulted in excessiver filler porosity. Though the outgassing from this porosity was found to be detrimental to the closeout layer structure, bond strengths in excess of 10,500 psi were achieved. Removal of the aluminum from the grooves was readily accomplished by leaching in a 7.0 molar solution of sodium hydroxide at 353 K. Of the other filler materials evaluated, CERROTRU was found to be the most suitable material with respect to completely filling the ribbed-wall cylinders and vacuum system compatibility. However, bond contamination resulted in low closeout layer bond strength with the CERROTRU filler. CERROBEND, CERROCAST, and SERMETEL 481 were found to be unacceptable as filler materials.
Laughner, Jacob I; Sulkin, Matthew S; Wu, Ziqi; Deng, Cheri X; Efimov, Igor R
2012-04-01
High intensity focused ultrasound (HIFU) has been introduced for treatment of cardiac arrhythmias because it offers the ability to create rapid tissue modification in confined volumes without directly contacting the myocardium. In spite of the benefits of HIFU, a number of limitations have been reported, which hindered its clinical adoption. In this study, we used a multimodal approach to evaluate thermal and nonthermal effects of HIFU in cardiac ablation. We designed a computer controlled system capable of simultaneous fluorescence mapping and HIFU ablation. Using this system, linear lesions were created in isolated rabbit atria (n=6), and point lesions were created in the ventricles of whole-heart (n=6) preparations by applying HIFU at clinical doses (4-16 W). Additionally, we evaluate the gap size in ablation lines necessary for conduction in atrial preparations (n=4). The voltage sensitive dye di-4-ANEPPS was used to assess functional damage produced by HIFU. Optical coherence tomography and general histology were used to evaluate lesion extent. Conduction block was achieved in 1 (17%) of 6 atrial preparations with a single ablation line. Following 10 minutes of rest, 0 (0%) of 6 atrial preparations demonstrated sustained conduction block from a single ablation line. Tissue displacement of 1 to 3 mm was observed during HIFU application due to acoustic radiation force along the lesion line. Additionally, excessive acoustic pressure and high temperature from HIFU generated cavitation, causing macroscopic tissue damage. A minimum gap size of 1.5 mm was found to conduct electric activity. This study identified 3 potential mechanisms responsible for the failure of HIFU ablation in cardiac tissues. Both acoustic radiation force and acoustic cavitation, in conjunction with inconsistent thermal deposition, can increase the risk of lesion discontinuity and result in gap sizes that promote ablation failure.
Angiero, Francesca; Parma, Luisa; Crippa, Rolando; Benedicenti, Stefano
2012-03-01
The diode laser is today widely used in oral pathology to excise lesions; however, some controversy surrounds laser surgery, specifically the accuracy of pathological diagnosis and the control over thermal tissue damage. This study aimed to establish if physical damage induced by the diode laser could affect the histopathological diagnosis and to evaluate the damage caused to the resection margins. Between 2005 and 2010, at S. Gerardo Hospital, Milan, 608 cases of soft tissue lesions localized in the oral cavity (cheek, gingiva, buccal mucosa, tongue, and lips) were examined. Specimens were excised with an 808-nm diode laser, output 1.6-2.7 W, in continuous-wave mode with fibers of 320 μm. Specimens were fixed in 10% buffered formalin solution and examined separately under an optical microscope by two pathologists. In all of the specimens, changes to the epithelium, connective tissue and blood vessels, shape of incision damage, and overall width of modified tissues were evaluated. The data for specimens larger than 3 mm excised with the diode laser were not significant in terms of stromal changes or vascular stasis, while epithelial and stromal changes were significantly more frequent in specimens with a mean size below 3 mm; the diagnosis was not achievable in 46.15%. Our data show that the diode laser is a valid therapeutic instrument for excising oral lesions larger than 3 mm in diameter, but induces serious thermal effects in small lesions (mean size below 3 mm). However, from a clinical standpoint, it is suggested necessary that the specimens taken have in vivo a diameter of at least 5 mm in order to have a reliable reading of the histological sample.
Vannozzi, Iacopo; Tesi, Matteo; Zangheri, Marta; Innocenti, Viola Maria; Rota, Alessandra; Citi, Simonetta; Poli, Alessandro
2018-06-01
Ultrasonography is a valuable tool for the evaluation of neoplastic lesions in the dog and there is a growing interest in the use of this technique for the stadiation of canine mammary tumours. An accurate assessment of small sized nodules facilitates the stadiation of the mammary lesions and helps the clinician in the choice of the most indicated surgical therapy. The aim of this study was to identify those ultrasound criteria that may be useful in discriminating between benign and malignant lesions of small size (diameter smaller than 2 cm). Sixty-two nodules, < 2 cm in larger diameter, belonging to thirty-five bitches presented between January 2012 and February 2014 were evaluated. Tumours were observed by conventional ultrasound and assessed for: shape (regular-irregular), limit (defined-ill-defined), margins (regular-irregular), echogenicity (hypoechoic-isoechoic-hyperecoic), echotexture (homogeneus-heterogeneus), presence of hyperecoic halo, distal acoustic enhancement or shadowing and surrounding tissue alterations. Among the alterations in surrounding tissues, the disruption of the glandular tissue and the increase in echogenicity of the peritumoral tissues were assessed. Thereafter, bitches were subjected to mastectomy and nodules were evaluated histologically. None of the ultasound criteria considered in the current study showed a statistically significant relation with malignancy, except for the presence of alterations in the tissue surrounding the nodules. According to our results, this characteristic may indicate malignancy, however its subjectivity may affect the applicability in clinical practice. In conclusions, conventional ultrasound in bitches had a limited ability in discriminating benign and malignant mammary gland neoplastic lesions of small size (diameter < 2 cm).
Hazen, S L; Gaut, J P; Crowley, J R; Hsu, F F; Heinecke, J W
2000-01-01
Reactive aldehydes might have a pivotal role in the pathogenesis of atherosclerosis by covalently modifying low-density lipoprotein (LDL). However, the identities of the aldehyde adducts that form on LDL in vivo are not yet clearly established. We previously demonstrated that the haem protein myeloperoxidase oxidizes proteins in the human artery wall. We also have shown that p-hydroxyphenylacetaldehyde (pHA), the aldehyde that forms when myeloperoxidase oxidizes L-tyrosine, covalently modifies the N(epsilon)-lysine residues of proteins. The resulting Schiff base can be quantified as N(epsilon)-[2-(p-hydroxyphenyl)ethyl]lysine (pHA-lysine) after reduction with NaCNBH(3). Here we demonstrate that pHA-lysine is a marker for LDL that has been modified by myeloperoxidase, and that water-soluble, but not lipid-soluble, antioxidants inhibit the modification of LDL protein. To determine whether myeloperoxidase-generated aldehydes might modify LDL in vivo, we used a combination of isotope-dilution GC-MS to quantify pHA-lysine in aortic tissues at various stages of lesion evolution. We also analysed LDL isolated from atherosclerotic aortic tissue. Comparison of normal and atherosclerotic aortic tissue demonstrated a significant elevation (more than 10-fold) of the reduced Schiff base adduct in fatty streaks, intermediate lesions and advanced lesions compared with normal aortic tissue. Moreover, the level of pHA-lysine in LDL recovered from atherosclerotic aortic intima was 200-fold that in plasma LDL of healthy donors. These results indicate that pHA-lysine, a specific covalent modification of LDL, is generated in human atherosclerotic vascular tissue. They also raise the possibility that reactive aldehydes generated by myeloperoxidase have a role in converting LDL into an atherogenic lipoprotein. PMID:11104675
Köhrmann, K U; Michel, M S; Steidler, A; Marlinghaus, E H; Kraut, O; Alken, P
2002-01-01
Therapeutic application of contactless thermoablation by high-intensity focused ultrasound (HIFU) demands precise physical definition of focal size and determination of control parameters. Our objective was to define the focal expansion of a new ultrasound generator and to evaluate the extent of tissue ablation under variable generator parameters in an ex vivo model. Axial and transversal distribution of ultrasound intensity in the area of the focal point was calculated by needle hydrophone. The extent of tissue necrosis after focused ultrasound was assessed in an ex vivo porcine kidney model applying generator power up to 400 Watt and pulse duration up to 8 s. The measurement of field distribution revealed a physical focal size of 32 x 4 mm. Sharp demarcation between coagulation necrosis and intact tissue was observed in our tissue model. Lesion size was kept under control by variation of both generator power and impulse duration. At a constant impulse duration of 2 s, generator power of 100 W remained below the threshold doses for induction of a reproducible lesion. An increase in power up to 200 W and 400 W, respectively, induced lesions with diameters up to 11.2 x 3 mm. Constant total energy (generator power x impulse duration) led to a larger lesion size under higher generator power. It is possible to induce sharply demarcated, reproducible thermonecrosis, which can be regulated by generator power and impulse duration, by means of a cylindrical piezo element with a paraboloid reflector at a focal distance of 10 cm. The variation of generator power was an especially suitable control parameter for the inducement of a defined lesion size.
Bible, Ellen; Dell’Acqua, Flavio; Solanky, Bhavana; Balducci, Anthony; Crapo, Peter; Badylak, Stephen F.; Ahrens, Eric T.; Modo, Michel
2012-01-01
Transplantation of human neural stem cells (hNSCs) is emerging as a viable treatment for stroke related brain injury. However, intraparenchymal grafts do not regenerate lost tissue, but rather integrate into the host parenchyma without significantly affecting the lesion cavity. Providing a structural support for the delivered cells appears important for cell based therapeutic approaches. The non-invasive monitoring of therapeutic methods would provide valuable information regarding therapeutic strategies but remains a challenge. Labeling transplanted cells with metal-based 1H-magnetic resonance imaging (MRI) contrast agents affects the visualization of the lesion cavity. Herein, we demonstrate that a 19F-MRI contrast agent can adequately monitor the distribution of transplanted cells, whilst allowing an evaluation of the lesion cavity and the formation of new tissue on 1H-MRI scans. Twenty percent of cells labeled with the 19F-agent were of host origin, potentially reflecting the re-uptake of label from dead transplanted cells. Both T2- and diffusion-weighted MRI scans indicated that transplantation of hNSCs suspended in a gel form of a xenogeneic extracellular matrix (ECM) bioscaffold resulted in uniformly distributed cells throughout the lesion cavity. However, diffusion MRI indicated that the injected materials did not yet establish diffusion barriers (i.e. cellular network, fiber tracts) normally found within striatal tissue. The ECM bioscaffold therefore provides an important support to hNSCs for the creation of de novo tissue and multi-nuclei MRI represents an adept method for the visualization of some aspects of this process. However, significant developments of both the transplantation paradigm, as well as regenerative imaging, are required to successfully create new tissue in the lesion cavity and to monitor this process non-invasively. PMID:22244696
NASA Astrophysics Data System (ADS)
Vigneswaran, Nadarajah
2011-03-01
Wide-filed autofluorescence examination is currently considered as a standard of care for screening and diagnostic evaluation of early neoplastic changes of the skin, cervix, lung, bladder, gastrointestinal tract and oral cavity. Naturally occurring fluorophores within the tissue absorb UV and visible light and can re-emit some of this light at longer wavelengths in the form of fluorescence. This non-invasive tissue autofluorescence imaging is used in optical diagnostics, especially in the early detection of cancer. Usually, malignant transformation is associated with thickening of the epithelium, enhanced cellular density due to increased nuclear cytoplasmic ratio which may attenuate the excitation leading to a decrease in collagen autofluorescence. Hence, dysplastic and cancerous tissues often exhibit decreased blue-green autofluorescence and appear darker compared to uninvolved mucosa. Currently, there are three commercially available devices to examine tissue autofluorescence in the oral cavity. In this study we used the oral cancer screening device IdentafiTM 3000 to examine the tissue reflectance and autofluorescence of PML and confounding lesions of the oral cavity. Wide-field autofluorescence imaging enables rapid inspection of large mucosal surfaces, to aid in recognition of suspicious lesions and may also help in discriminate the PML (class 1) from some of the confounding lesions (class II). However, the presence of inflammation or pigments is also associated with loss of stromal autofluorescence, and may give rise to false-positive results with widefield fluorescence imaging. Clinicians who use these autofluorescence based oral cancer screening devices should be aware about the benign oral mucosal lesions that may give false positivity so that unnecessary patient's anxiety and the need for scalpel biopsy can be eliminated.
Quantitative Analysis of Immunohistochemistry in Melanoma Tumors
Lilyquist, Jenna; White, Kirsten Anne Meyer; Lee, Rebecca J.; Philips, Genevieve K.; Hughes, Christopher R.; Torres, Salina M.
2017-01-01
Abstract Identification of positive staining is often qualitative and subjective. This is particularly troublesome in pigmented melanoma lesions, because melanin is difficult to distinguish from the brown stain resulting from immunohistochemistry (IHC) using horse radish peroxidase developed with 3,3′-Diaminobenzidine (HRP-DAB). We sought to identify and quantify positive staining, particularly in melanoma lesions. We visualized G-protein coupled estrogen receptor (GPER) expression developed with HRP-DAB and counterstained with Azure B (stains melanin) in melanoma tissue sections (n = 3). Matched sections (n = 3), along with 22 unmatched sections, were stained only with Azure B as a control. Breast tissue (n = 1) was used as a positive HRP-DAB control. Images of the stained tissues were generated using a Nuance Spectral Imaging Camera. Analysis of the images was performed using the Nuance Spectral Imaging software and SlideBook. Data was analyzed using a Kruskal–Wallis one way analysis of variance (ANOVA). We showed that a pigmented melanoma tissue doubly stained with anti-GPER HRP-DAB and Azure B can be unmixed using spectra derived from a matched, Azure B-only section, and an anti-GPER HRP-DAB control. We unmixed each of the melanoma lesions using each of the Azure B spectra, evaluated the mean intensity of positive staining, and examined the distribution of the mean intensities (P = .73; Kruskal–Wallis). These results suggest that this method does not require a matched Azure B-only stained control tissue for every melanoma lesion, allowing precious tissues to be conserved for other studies. Importantly, this quantification method reduces the subjectivity of protein expression analysis, and provides a valuable tool for accurate evaluation, particularly for pigmented tissues. PMID:28403073
Hadziabdic, Naida; Kurtovic-Kozaric, Amina; Pojskic, Naris; Sulejmanagic, Nedim; Todorovic, Ljubomir
2016-03-01
Periapical inflammatory lesions have been investigated previously, but understanding of pathogenesis of these lesions (granulomas and radicular cysts) at the molecular level is still questionable. Matrix metalloproteinases (MMPs) are enzymes involved in the development of periapical pathology, specifically inflammation and tissue destruction. To elucidate pathogenesis of periapical granulomas and radicular cysts, we undertook a detailed analysis of gene expression of MMP-1, MMP-2 and their tissue inhibitors, TIMP-1 and TIMP-2. A total of 149 samples were analyzed using real-time PCR (59 radicular cysts, 50 periapical granulomas and 40 healthy gingiva samples as controls) for expression of MMP-1, MMP-2, TIMP-1 and TIMP-2 genes. The determination of best reference gene for expression analysis of periapical lesions was done using a panel of 12 genes. We have shown that β-actin and GAPDH are not the most stable reference controls for gene expression analysis of inflammatory periapical tissues and healthy gingiva. The most suitable reference gene was determined to be SDHA (a succinate dehydrogenase complex, subunit A, flavoprotein [Fp]). We found that granulomas (n = 50) and radicular cysts (n = 59) exhibited significantly higher expression of all four examined genes, MMP-1, MMP-2, TIMP-1, and TIMP-2, when compared to healthy gingiva (n = 40; P < 0.05). This study has confirmed that the expression of MMP-1, MMP-2, TIMP-1, and TIMP-2 genes is important for the pathogenesis of periapical inflammatory lesions. Since the abovementioned markers were not differentially expressed in periapical granulomas and radicular cysts, the challenge of finding the genetic differences between the two lesions still remains. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Filler metal alloy for welding cast nickel aluminide alloys
Santella, M.L.; Sikka, V.K.
1998-03-10
A filler metal alloy used as a filler for welding cast nickel aluminide alloys contains from about 15 to about 17 wt. % chromium, from about 4 to about 5 wt. % aluminum, equal to or less than about 1.5 wt. % molybdenum, from about 1 to about 4.5 wt. % zirconium, equal to or less than about 0.01 wt. % yttrium, equal to or less than about 0.01 wt. % boron and the balance nickel. The filler metal alloy is made by melting and casting techniques such as are melting the components of the filler metal alloy and cast in copper chill molds. 3 figs.
Improvement of Scratch and Wear Resistance of Polymers by Fillers Including Nanofillers
Brostow, Witold; Lobland, Haley E. Hagg; Hnatchuk, Nathalie; Perez, Jose M.
2017-01-01
Polymers have lower resistance to scratching and wear than metals. Liquid lubricants work well for metals but not for polymers nor for polymer-based composites (PBCs). We review approaches for improvement of tribological properties of polymers based on inclusion of fillers. The fillers can be metallic or ceramic—with obvious consequences for electrical resistivity of the composites. Distinctions between effectiveness of micro- versus nano-particles are analyzed. For example, aluminum nanoparticles as filler are more effective for property improvement than microparticles at the same overall volumetric concentration. Prevention of local agglomeration of filler particles is discussed along with a technique to verify the prevention. PMID:28336900
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2014 CFR
2014-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2012 CFR
2012-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
21 CFR 882.4400 - Radiofrequency lesion generator.
Code of Federal Regulations, 2013 CFR
2013-04-01
... lesions in the nervous system or other tissue by the direct application of radiofrequency currents to... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiofrequency lesion generator. 882.4400 Section 882.4400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Hartomy, Omar A.; Department of Physics, Faculty of Science, University of Tabuk, Tabuk 71491; Al-Ghamdi, Ahmed A.
2015-03-15
Dual phase carbon–silica hybrid fillers obtained by pyrolysis-cum-water vapor of waste green tires have been characterized by energy dispersive X-ray spectroscopy in a scanning transmission electron microscope, silicate analysis, weight analysis, atomic absorption spectroscopy and by inductively coupled plasma–optical emission spectroscopy. The results achieved have shown that the location and distribution of the phases in the carbon silica hybrid fillers as well as their most essential characteristics are influenced by the pyrolysis conditions. The carbon phase of the filler thus obtained is located predominantly in the space among silica aggregates which have already been existing while it has been formedmore » by elastomer destruction in the course of pyrolysis. The presence of ZnS also has been found in the hybrid fillers investigated. - Highlights: • Dual phase fillers obtained by pyrolysis of waste green tires have been characterized. • The STEM–EDX method was used for characterization. • The phase distributions in the fillers are influenced by the pyrolysis conditions.« less
Wide gap active brazing of ceramic-to-metal-joints for high temperature applications
NASA Astrophysics Data System (ADS)
Bobzin, K.; Zhao, L.; Kopp, N.; Samadian Anavar, S.
2014-03-01
Applications like solid oxide fuel cells and sensors increasingly demand the possibility to braze ceramics to metals with a good resistance to high temperatures and oxidative atmospheres. Commonly used silver based active filler metals cannot fulfill these requirements, if application temperatures higher than 600°C occur. Au and Pd based active fillers are too expensive for many fields of use. As one possible solution nickel based active fillers were developed. Due to the high brazing temperatures and the low ductility of nickel based filler metals, the modification of standard nickel based filler metals were necessary to meet the requirements of above mentioned applications. To reduce thermally induced stresses wide brazing gaps and the addition of Al2O3 and WC particles to the filler metal were applied. In this study, the microstructure of the brazed joints and the thermo-chemical reactions between filler metal, active elements and WC particles were analyzed to understand the mechanism of the so called wide gap active brazing process. With regard to the behavior in typical application oxidation and thermal cycle tests were conducted as well as tensile tests.
NASA Astrophysics Data System (ADS)
Sicinski, M.; Gozdek, T.; Bielinski, D. M.; Szymanowski, H.; Kleczewska, J.; Piatkowska, A.
2015-07-01
In modern rubber industry, there still is a room for new fillers, which can improve the mechanical properties of the composites, or introduce a new function to the material. Modern fillers like carbon nanotubes or graphene nanoplatelets (GnP), are increasingly applied in advanced polymer composites technology. However, it might be hard to obtain a well dispersed system for such systems. The polymer matrix often exhibits higher surface free energy (SFE) level with the filler, which can cause problems with polymer-filler interphase adhesion. Filler particles are not wet properly by the polymer, and thus are easier to agglomerate. As a consequence, improvement in the mechanical properties is lower than expected. In this work, multi-walled carbon nanotubes (MWCNT) and GnP surface were modified with low-temperature plasma. Attempts were made to graft some functionalizing species on plasma-activated filler surface. The analysis of virgin and modified fillers’ SFE was carried out. MWCNT and GnP rubber composites were produced, and ultimately, their morphology and mechanical properties were studied.
Bleach, N C; Nazhat, S N; Tanner, K E; Kellomäki, M; Törmälä, P
2002-04-01
A bioabsorbable self-reinforced polylactide/biphasic calcium phosphate (BCP) composite is being developed for fracture fixation plates. One manufacturing route is to produce preimpregnated sheets by pulling polylactide (PLA) fibres through a suspension of BCP filler in a PLA solution and compression moulding the prepreg to the desired shape. To aid understanding of the process, interactions between the matrix and filler were investigated. Composite films containing 0-0.25 volume fraction filler, produced by solvent casting, were analysed using SEM, tensile testing and dynamic mechanical analysis (DMA). Homogeneous films could be made, although some particle agglomeration was seen at higher filler volume fractions. As the filler content increased, the failure strain decreased due to a reduction in the amount of ductile polymer present and the ultimate tensile strength (UTS) decreased because of agglomeration and void formation at higher filler content. The matrix glass transition temperature increased due to polymer chain adsorption and immobilization onto the BCP particles. Complex damping mechanisms, such as particle-particle agglomeration, may exist at the higher BCP volume fractions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glickman, R.D.; Gritz, D.C.; Held, K.S.
the clinical diagnosis of a lesion often requires that a histological analysis be made of a physical specimen of the suspect tissue. In the present work, the authors have utilized an optical biopsy system (OBS) developed at Los Alamos National Laboratory which is safe for patient use and provides a large amount of optical data from the sampled tissue. An earlier version of this system has been used to study age-related changes in the ocular lens (10). The purpose of the present study is to establish the potential clinical utility of the OBS by determining if characteristic features in themore » optical signatures, obtained from a variety of ophthalmic lesions, are correlated with the histological features of tissue biopsies obtained from these patients.« less
Primary Orbital Chondromyxoid Fibroma: A Rare Case.
Mullen, Martin G; Somogyi, Marie; Maxwell, Sean P; Prabhu, Vikram; Yoo, David K
A 56-year-old male with history of chronic sinusitis was found to have a 3 cm left orbital lesion on CT. Subsequent MRI demonstrated a multilobulated enhancing soft tissue lesion at the superotemporal region of the left orbit. Initial biopsy was reported as a low-grade sarcoma. On further evaluation, a consensus was made that the lesion was likely a benign mixed mesenchymal type tumor but should nonetheless be surgically removed. Left lateral orbitotomy was performed which revealed a tumor originating in the lateral orbital bone with segments eroding through the wall of the orbit. Intraoperative frozen sections revealed myoepitheliod tissue with locally aggressive features and the tumor was completely removed. The final histopathologic analysis of the tissue was consistent with a chondromyxoid fibroma. Chondomyxoid fibroma is a rare entity in the orbital bones and is more commonly seen in long bones.
Kempker, Russell R; Heinrichs, M Tobias; Nikolaishvili, Ketino; Sabulua, Irina; Bablishvili, Nino; Gogishvili, Shota; Avaliani, Zaza; Tukvadze, Nestani; Little, Brent; Bernheim, Adam; Read, Timothy D; Guarner, Jeannette; Derendorf, Hartmut; Peloquin, Charles A; Blumberg, Henry M; Vashakidze, Sergo
2017-06-01
Improved knowledge regarding the tissue penetration of antituberculosis drugs may help optimize drug management. Patients with drug-resistant pulmonary tuberculosis undergoing adjunctive surgery were enrolled. Serial serum samples were collected, and microdialysis was performed using ex vivo lung tissue to measure pyrazinamide concentrations. Among 10 patients, the median pyrazinamide dose was 24.7 mg/kg of body weight. Imaging revealed predominant lung lesions as cavitary ( n = 6 patients), mass-like ( n = 3 patients), or consolidative ( n = 1 patient). On histopathology examination, all tissue samples had necrosis; eight had a pH of ≤5.5. Tissue samples from two patients were positive for Mycobacterium tuberculosis by culture (pH 5.5 and 7.2). All 10 patients had maximal serum pyrazinamide concentrations within the recommended range of 20 to 60 μg/ml. The median lung tissue free pyrazinamide concentration was 20.96 μg/ml. The median tissue-to-serum pyrazinamide concentration ratio was 0.77 (range, 0.54 to 0.93). There was a significant inverse correlation between tissue pyrazinamide concentrations and the amounts of necrosis ( R = -0.66, P = 0.04) and acid-fast bacilli ( R = -0.75, P = 0.01) identified by histopathology. We found good penetration of pyrazinamide into lung tissue among patients with pulmonary tuberculosis with a variety of radiological lesion types. Our tissue pH results revealed that most lesions had a pH conducive to pyrazinamide activity. The tissue penetration of pyrazinamide highlights its importance in both drug-susceptible and drug-resistant antituberculosis treatment regimens. Copyright © 2017 American Society for Microbiology.
Lung Tissue Concentrations of Pyrazinamide among Patients with Drug-Resistant Pulmonary Tuberculosis
Heinrichs, M. Tobias; Nikolaishvili, Ketino; Sabulua, Irina; Bablishvili, Nino; Gogishvili, Shota; Avaliani, Zaza; Tukvadze, Nestani; Little, Brent; Bernheim, Adam; Read, Timothy D.; Guarner, Jeannette; Derendorf, Hartmut; Peloquin, Charles A.; Blumberg, Henry M.; Vashakidze, Sergo
2017-01-01
ABSTRACT Improved knowledge regarding the tissue penetration of antituberculosis drugs may help optimize drug management. Patients with drug-resistant pulmonary tuberculosis undergoing adjunctive surgery were enrolled. Serial serum samples were collected, and microdialysis was performed using ex vivo lung tissue to measure pyrazinamide concentrations. Among 10 patients, the median pyrazinamide dose was 24.7 mg/kg of body weight. Imaging revealed predominant lung lesions as cavitary (n = 6 patients), mass-like (n = 3 patients), or consolidative (n = 1 patient). On histopathology examination, all tissue samples had necrosis; eight had a pH of ≤5.5. Tissue samples from two patients were positive for Mycobacterium tuberculosis by culture (pH 5.5 and 7.2). All 10 patients had maximal serum pyrazinamide concentrations within the recommended range of 20 to 60 μg/ml. The median lung tissue free pyrazinamide concentration was 20.96 μg/ml. The median tissue-to-serum pyrazinamide concentration ratio was 0.77 (range, 0.54 to 0.93). There was a significant inverse correlation between tissue pyrazinamide concentrations and the amounts of necrosis (R = −0.66, P = 0.04) and acid-fast bacilli (R = −0.75, P = 0.01) identified by histopathology. We found good penetration of pyrazinamide into lung tissue among patients with pulmonary tuberculosis with a variety of radiological lesion types. Our tissue pH results revealed that most lesions had a pH conducive to pyrazinamide activity. The tissue penetration of pyrazinamide highlights its importance in both drug-susceptible and drug-resistant antituberculosis treatment regimens. PMID:28373198
Ye, Yuan; Yuan, Yi; Lu, Feng; Gao, Jianhua
2015-12-01
In plastic and reconstructive surgery, adipose tissue is widely used as effective filler for tissue defects. Strategies for treating soft tissue deficiency, which include free adipose tissue grafts, use of hyaluronic acid, collagen injections, and implantation of synthetic materials, have several clinical limitations. With the aim of overcoming these limitations, researchers have recently utilized tissue engineering chambers to produce large volumes of engineered vascularized fat tissue. However, the process of growing fat tissue in a chamber is still relatively limited, and can result in unpredictable or dissatisfactory final tissue volumes. Therefore, detailed understanding of the process is both necessary and urgent. Many studies have shown that mechanical force can change the function of cells via mechanotransduction. Here, we hypothesized that, besides the inflammatory response, one of the key factors to control the regeneration of vascularized fat flap inside a tissue engineering chamber might be the balance of mechanical forces. To test our hypothesis, we intend to change the balance of forces by means of measures in order to make the equilibrium point in favor of the direction of regeneration. If those measures proved to be feasible, they could be applied in clinical practice to engineer vascularized adipose tissue of predictable size and shape, which would in turn help in the advancement of tissue engineering. Copyright © 2015 Elsevier Ltd. All rights reserved.
Melorheostosis with recurrent soft-tissue components: a histologically confirmed case.
Hasegawa, Shoichi; Kanda, Shotaro; Imada, Hiroki; Yamaguchi, Takehiko; Akiyama, Toru
2017-03-01
Melorheostosis is a very rare disorder characterized by irregular cortical thickening seen on radiographs. In this paper, we present a case of melorheostosis with microscopically confirmed soft-tissue components. The patient was a 51-year-old man who complained of severe pain in the lateral aspect of his right knee. The excision of an ossified soft-tissue lesion relieved intractable pain that had lasted 20 years. Microscopically, the cortex of the affected fibula was composed of thick compact bone and the soft-tissue component consisted of dense compact bone without endochondral ossification. The presence of soft-tissue osseous nodules around the joints is one of the specific conditions for melorheostosis and should be differentiated from synovial chondromatosis. The ossified soft-tissue lesion in our patient is to our knowledge the first reported case of the histologically confirmed soft-tissue component of melorheostosis, which differs from that of synovial chondromatosis.
Connective tissue responses to some heavy metals. II. Lead: histology and ultrastructure.
Ellender, G.; Ham, K. N.
1987-01-01
Lead loaded ion exchange resin beads implanted into the loose connective tissue of the rat pinna induced local lesions which differed widely from those of the control (sodium loaded) beads (Ellender & Ham 1987). These lesions were characterized by changes in the granulation tissue and the approximating connective tissue. Granulation tissue contained mononuclear phagocytes in various guises, and some cells with intranuclear inclusion bodies. The matrix of the granulation tissue contained collagen fibrils having a wide range of diameters suggestive of altered collagen biosynthesis. Foci of collagen mineralization occurred in zones of combined trauma and lead impregnation. Once mineralized they became enveloped by giant cells and epithelioid cells. Lead in damaged tissues is thought to modify the protective mechanism of calcification inhibition and the biosynthesis of the matrix. Images Fig. 6 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Fig. 12 Fig. 13 PMID:3040063
Nouh, Mohamed Ragab; Amr, Hanan Abd El-Aziz; Ali, Rola H
2018-06-01
Background Soft-tissue chondroma (STC) is a rare benign soft tissue tumor that arises primarily in acral extra-skeletal locations. Occasionally, STCs may arise in more proximal non-acral locations, accompanied by non-classic features that label them as indeterminate lesions and pose diagnostic challenge for both radiologists and pathologists alike. Purpose To explicate the potential of diagnostic imaging in the identification and characterization of appendicular non-acral STCs with emphasis on their morphologic magnetic resonance imaging (MRI) enhancement. Material and Methods Our clinical database records were searched for patients with histologically proven primary soft-tissue chondroid lesions over a five-year period. Two musculoskeletal (MSK) trained radiologists evaluated the imaging studies and an MSK pathologist revised the pathological findings. Results The study included six cases of appendicular non-acral STCs (mean age = 40.5 years). The mean size of the tumors was 5.6 cm, with four localized to the knee region, one in the thigh, and one in the sternoclavicular region. All cases showed high signal intensity matrix with low-signal intensity septa on T2-weighted MRI and post-contrast marginal/septal enhancement. The lesions were lobulated and lacked host tissue reaction except for one showing subjacent mild soft-tissue edema. Histologically, the cases lacked overt features of malignancy although one was originally misdiagnosed as chondrosarcoma. Conclusion Non-acral STCs are benign cartilaginous tumors that may pose a diagnostic challenge, both radiologically and pathologically. Collaborative imaging and pathologic workup is needed for better characterization of non-aggression of these lesions, and to avoid diagnostic pitfalls and unnecessary radical resections.
Iron Is a Sensitive Biomarker for Inflammation in Multiple Sclerosis Lesions
Mehta, Veela; Pei, Wei; Yang, Grant; Li, Suyang; Swamy, Eashwar; Boster, Aaron; Schmalbrock, Petra; Pitt, David
2013-01-01
MRI phase imaging in multiple sclerosis (MS) patients and in autopsy tissue have demonstrated the presence of iron depositions in white matter lesions. The accumulation of iron in some but not all lesions suggests a specific, potentially disease-relevant process, however; its pathophysiological significance remains unknown. Here, we explore the role of lesional iron in multiple sclerosis using multiple approaches: immunohistochemical examination of autoptic MS tissue, an in vitro model of iron-uptake in human cultured macrophages and ultra-highfield phase imaging of highly active and of secondary progressive MS patients. Using Perls' stain and immunohistochemistry, iron was detected in MS tissue sections predominantly in non-phagocytosing macrophages/microglia at the edge of established, demyelinated lesions. Moreover, iron-containing macrophages but not myelin-laden macrophages expressed markers of proinflammatory (M1) polarization. Similarly, in human macrophage cultures, iron was preferentially taken up by non-phagocytosing, M1-polarized macrophages and induced M1 (super) polarization. Iron uptake was minimal in myelin-laden macrophages and active myelin phagocytosis led to depletion of intracellular iron. Finally, we demonstrated in MS patients using GRE phase imaging with ultra-highfield MRI that phase hypointense lesions were significantly more prevalent in patients with active relapsing than with secondary progressive MS. Taken together, our data provide a basis to interpret iron-sensitive GRE phase imaging in MS patients: iron is present in non-phagocytosing, M1-polarized microglia/macrophages at the rim of chronic active white matter demyelinating lesions. Phase imaging may therefore visualize specific, chronic proinflammatory activity in established MS lesions and thus provide important clinical information on disease status and treatment efficacy in MS patients. PMID:23516409
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cho, H; Ding, H; Sennung, D
2015-06-15
Purpose: To investigate the feasibility of measuring breast lesion composition with spectral mammography using physical phantoms and bovine tissue. Methods: Phantom images were acquired with a spectral mammography system with a silicon-strip based photon-counting detector. Plastic water and adipose-equivalent phantoms were used to calibrate the system for dual-energy material decomposition. The calibration phantom was constructed in range of 2–8 cm thickness and water densities in the range of 0% to 100%. A non-linear rational fitting function was used to calibrate the imaging system. The phantom studies were performed with uniform background phantom and non-uniform background phantom. The breast lesion phantomsmore » (2 cm in diameter and 0.5 cm in thickness) were made with water densities ranging from 0 to 100%. The lesion phantoms were placed in different positions and depths on the phantoms to investigate the accuracy of the measurement under various conditions. The plastic water content of the lesion was measured by subtracting the total decomposed plastic water signal from a surrounding 2.5 mm thick border outside the lesion. In addition, bovine tissue samples composed of 80 % lean were imaged as background for the simulated lesion phantoms. Results: The thickness of measured and known water contents was compared. The rootmean-square (RMS) errors in water thickness measurements were 0.01 cm for the uniform background phantom, 0.04 cm for non-uniform background phantom, and 0.03 cm for 80% lean bovine tissue background. Conclusion: The results indicate that the proposed technique using spectral mammography can be used to accurately characterize breast lesion compositions.« less
Harmouche, Rola; Subbanna, Nagesh K; Collins, D Louis; Arnold, Douglas L; Arbel, Tal
2015-05-01
In this paper, a fully automatic probabilistic method for multiple sclerosis (MS) lesion classification is presented, whereby the posterior probability density function over healthy tissues and two types of lesions (T1-hypointense and T2-hyperintense) is generated at every voxel. During training, the system explicitly models the spatial variability of the intensity distributions throughout the brain by first segmenting it into distinct anatomical regions and then building regional likelihood distributions for each tissue class based on multimodal magnetic resonance image (MRI) intensities. Local class smoothness is ensured by incorporating neighboring voxel information in the prior probability through Markov random fields. The system is tested on two datasets from real multisite clinical trials consisting of multimodal MRIs from a total of 100 patients with MS. Lesion classification results based on the framework are compared with and without the regional information, as well as with other state-of-the-art methods against the labels from expert manual raters. The metrics for comparison include Dice overlap, sensitivity, and positive predictive rates for both voxel and lesion classifications. Statistically significant improvements in Dice values ( ), for voxel-based and lesion-based sensitivity values ( ), and positive predictive rates ( and respectively) are shown when the proposed method is compared to the method without regional information, and to a widely used method [1]. This holds particularly true in the posterior fossa, an area where classification is very challenging. The proposed method allows us to provide clinicians with accurate tissue labels for T1-hypointense and T2-hyperintense lesions, two types of lesions that differ in appearance and clinical ramifications, and with a confidence level in the classification, which helps clinicians assess the classification results.
Spontaneous progression of experimentally induced periimplantitis.
Zitzmann, N U; Berglundh, T; Ericsson, I; Lindhe, J
2004-10-01
Periimplantitis represents an inflammatory condition that is associated with the presence of a submarginal biofilm and with advanced breakdown of soft and mineralized tissues surrounding endosseous implants. Animal models have been used to describe mechanisms involved in the pathogenesis and treatment of the soft and hard tissue lesions of periimplantitis. The aim of the present experiment was to study the presence and progression of inflammatory lesions in tissues surrounding implants exposed to "experimental periimplantitis". Five Labrador dogs were used. In each dog, 2 or 3 implants were placed in both the left and right edentulous premolar regions of the mandible. Abutment connection was performed 4 months later and a plaque control regimen was initiated and maintained for 5 months. "Experimental periimplantitis" was subsequently induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. The ligatures were removed, but plaque formation was allowed to continue for an additional 12 months. Radiographs of all implant sites were obtained before and after active "experimental periimplantitis" as well as at the end of the experiment. Biopsies were harvested from the implant sites in 3 of the dogs. The tissue samples were prepared for light microscopy and the sections were used for histometric and morphometric examinations. One implant was lost during the first 2 months of "experimental periimplantitis" and two implants were lost during the 12 months that followed ligature removal. The radiographic examination indicated that varying amounts of additional bone loss occurred in the majority of the implant sites also following ligature removal. The mucosa of all implant sites harbored inflammatory lesions that extended apically of the pocket epithelium. The lesions were separated from the marginal bone by a zone of apparently normal connective tissue. A remission of the destructive inflammatory lesion in the periimplant tissues was seen in some sites following ligature removal, but in the majority of sites additional loss of supporting bone occurred. Copyright Blackwell Munksgaard, 2004
The roles of autophagy and hypoxia in human inflammatory periapical lesions.
Huang, H Y; Wang, W C; Lin, P Y; Huang, C P; Chen, C Y; Chen, Y K
2018-02-01
To determine the expressions of hypoxia-related [hypoxia-inducible transcription factors (HIF)-1α, BCL2/adenovirus E1B 19 kDa protein-interacting protein 3 (BNIP3) and phospho-adenosine monophosphate activated protein kinase (pAMPK)] and autophagy-related [microtubule-associated protein 1 light chain 3 (LC3), beclin-1 (BECN-1), autophagy-related gene (Atg)5-12, and p62] proteins in human inflammatory periapical lesions. Fifteen samples of radicular cysts (RCs) and 21 periapical granulomas (PGs), combined with 17 healthy dental pulp tissues, were examined. Enzyme-linked immunosorbent assay (ELISA) was used to detect interleukin (IL)-1β cytokine; immunohistochemical (IHC) and Western blot (WB) analyses were employed to examine autophagy-related and hypoxia-related proteins. Transmission electron microscopy (TEM) was used to explore the ultrastructural morphology of autophagy in periapical lesions. Nonparametric Kruskal-Wallis tests and Mann-Whitney U-tests were used for statistical analyses. ELISA revealed a significantly higher (P < 0.001) IL-1β expression in periapical lesions than in normal pulp tissue. Immunoscores of IHC expressions of pAMPK, HIF-1α, BNIP3, BECN-1 and Atg5-12 proteins in periapical lesions were significantly higher (P < 0.001) (except BECN-1) than those in normal pulp tissue. The results of IHC studies were largely compatible with those of WB analyses, where significantly higher (P < 0.05) expressions of hypoxia-related and autophagy-related proteins (except BECN-1, p62 and LC3II in WB analyses) in periapical lesions were noted as compared to normal pulp tissue. Upon TEM, ultrastructural double-membrane autophagosomes and autolysosomes were observed in PGs and RCs. Autophagy associated with hypoxia may play a potential causative role in the development and maintenance of inflamed periapical lesions. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Cenić-Milosević, Desanka; Mileusnić, Ivan; Kolak, Veljko; Pejanović, Djordje; Ristić, Tamara; Jakovljević, Ankica; Popović, Milica; Pesić, Dragana; Melih, Irena
2013-08-01
Environmental lead (Pb) pollution is a global problem. Hard dental tissue is capable of accumulating lead and other hard metals from the environment. The aim of this study was to investigate any correlation between the concentration of lead in teeth extracted from inhabitants of Pancevo and Belgrade, Serbia, belonging to different age groups and occurrence of tooth loss, caries and non-carious lesions. A total of 160 volunteers were chosen consecutively from Pancevo (the experimental group) and Belgrade (the control group) and divided into 5 age subgroups of 32 subjects each. Clinical examination consisted of caries and hard dental tissue diagnostics. The Decayed Missing Filled Teeth (DMFT) Index and Significant Caries Index were calculated. Extracted teeth were freed of any organic residue by UV digestion and subjected to voltammetric analysis for the content of lead. The average DMFT scores in Pancevo (20.41) were higher than in Belgrade (16.52); in the patients aged 31-40 and 41-50 years the difference was significant (p < 0.05) and highly significant in the patients aged 51-60 (23.69 vs 18.5, p < 0.01). Non-carious lesions were diagnosed in 71 (44%) patients from Pancevo and 39 (24%) patients from Belgrade. The concentrations of Pb in extracted teeth in all the groups from Pancevo were statistically significantly (p < 0.05) higher than in all the groups from Belgrade. In the patients from Pancevo correlations between Pb concentration in extracted teeth and the number of extracted teeth, the number of carious lesions and the number of non-carious lesions showed a statistical significance (p < 0.001, p < 0.01 andp < 0.001, respectively). According to correlations between lead concentration and the number of extracted teeth, number of carious lesions and non-carious lesions found in the patients living in Pancevo, one possible cause of tooth loss and hard dental tissue damage could be a long-term environmental exposure to lead.
Endometriosis Is Characterized by a Distinct Pattern of Histone 3 and Histone 4 Lysine Modifications
Monteiro, Janice B.; Colón-Díaz, Maricarmen; García, Miosotis; Gutierrez, Sylvia; Colón, Mariano; Seto, Edward; Laboy, Joaquín
2014-01-01
Background: The histone modification patterns in endometriosis have not been fully characterized. This gap in knowledge results in a poor understanding of the epigenetic mechanisms (and potential therapeutic targets) at play. We aimed to (1) assess global acetylation status of histone 3 (H3) and histone 4 (H4), (2) measure levels of H3 and H4 lysine (K) acetylation and methylation, and (3) to identify histone acetylation patterns in promoter regions of candidate genes in tissues from patients and controls. Methods: Global and K-specific acetylation/methylation levels of histones were measured in 24 lesions, 15 endometrium from patients, and 26 endometrium from controls. Chromatin immunoprecipitation (ChIP)–polymerase chain reaction was used to determine the histone acetylation status of the promoter regions of candidate genes in tissues. Results: The lesions were globally hypoacetylated at H3 (but not H4) compared to eutopic endometrium from controls. Lesions had significantly lower levels of H3K9ac and H4K16ac compared to eutopic endometrium from patients and controls. Tissues from patients were hypermethylated at H3K4, H3K9, and H3K27 compared to endometrium from controls. The ChIP analysis showed hypoacetylation of H3/H4 within promoter regions of candidate genes known to be downregulated in endometriosis (e.g., HOXA10, ESR1, CDH1, and p21WAF1/Cip1) in lesions versus control endometrium. The stereoidogenic factor 1 (SF1) promoter region was enriched for acetylated H3 and H4 in lesions versus control tissues, correlating with its reported high expression in lesions. Conclusions: This study describes the histone code of lesions and endometrium from patients with endometriosis and provides support for a possible role of histone modification in modulation of gene expression in endometriosis. PMID:23899551
Torrefied biomass-polypropylene composites
USDA-ARS?s Scientific Manuscript database
Torrefied almond shells and wood chips were incorporated into polypropylene as fillers to produce torrefied biomass-polymer composites. Response surface methodology was used to examine the effects of filler concentration, filler size, and lignin factor (relative lignin to cellulose concentration) on...
Improved TIG weld joint strength in aluminum alloy 2219-T87 by filler metal substitution
NASA Technical Reports Server (NTRS)
Poorman, R. M.; Lovoy, C. V.
1972-01-01
The results of an investigation on weld joint characteristics of aluminum alloy 2219-T87 are given. Five different alloys were utilized as filler material. The mechanical properties of the joints were determined at ambient and cryogenic temperatures for weldments in the as-welded condition and also, for weldments after elevated temperature exposures. Other evaluations included hardness surveys, stress corrosion susceptibility, and to a limited extent, the internal metallurgical weld structures. The overall results indicate that M-943 filler weldments are superior in strength to weldments containing either the standard 2319 filler or fillers 2014, 2020, and a dual wire feed consisting of three parts 2319 and one part 5652. In addition, no deficiencies were evident in M-934 filler weldments with regard to ductility, joint strength after elevated temperature exposure, weld hardness, metallographic structures, or stress corrosion susceptibility.
The disfluent discourse: Effects of filled pauses on recall
Fraundorf, Scott H.; Watson, Duane G.
2011-01-01
We investigated the mechanisms by which fillers, such as uh and um, affect memory for discourse. Participants listened to and attempted to recall recorded passages adapted from Alice’s Adventures in Wonderland. The type and location of interruptions were manipulated through digital splicing. In Experiment 1, we tested a processing time account of fillers’ effects. While fillers facilitated recall, coughs matched in duration to the fillers impaired recall, suggesting that fillers’ benefits cannot be attributed to adding processing time. In Experiment 2, fillers’ locations were manipulated based on norming data to be either predictive or non-predictive of upcoming material. Fillers facilitated recall in both cases, inconsistent with an account in which listeners predict upcoming material using past experience with the distribution of fillers. Instead, these results suggest an attentional orienting account in which fillers direct attention to the speech stream but do not always result in specific predictions about upcoming material. PMID:21765590
Pediatric Benign Soft Tissue Oral and Maxillofacial Pathology.
Glickman, Alexandra; Karlis, Vasiliki
2016-02-01
Despite the many types of oral pathologic lesions found in infants and children, the most commonly encountered are benign soft tissue lesions. The clinical features, diagnostic criteria, and treatment algorithms of pathologies in the age group from birth to 18 years of age are summarized based on their prevalence in each given age distribution. Treatment modalities include both medical and surgical management. Copyright © 2016 Elsevier Inc. All rights reserved.
Yan, Shengjie; Wu, Xiaomei; Wang, Weiqi
2017-09-01
Radiofrequency (RF) energy is often used to create a linear lesion or discrete lesions for blocking the accessory conduction pathways for treating atrial fibrillation. By using finite element analysis, we study the ablation effect of amplitude control ablation mode (AcM) and bipolar ablation mode (BiM) in creating a linear lesion and discrete lesions in a 5-mm-thick atrial wall; particularly, the characteristic of lesion shape has been investigated in amplitude control ablation. Computer models of multipolar catheter were developed to study the lesion dimensions in atrial walls created through AcM, BiM and special electrodes activated ablation methods in AcM and BiM. To validate the theoretical results in this study, an in vitro experiment with porcine cardiac tissue was performed. At 40 V/20 V root mean squared (RMS) of the RF voltage for AcM, the continuous and transmural lesion was created by AcM-15s, AcM-5s and AcM-ad-20V ablation in 5-mm-thick atrial wall. At 20 V RMS for BiM, the continuous but not transmural lesion was created. AcM ablation yielded asymmetrical and discrete lesions shape, whereas the lesion shape turned to more symmetrical and continuous as the electrodes alternative activated period decreased from 15 s to 5 s. Two discrete lesions were created when using AcM, AcM-ad-40V, BiM-ad-20V and BiM-ad-40V. The experimental and computational thermal lesion shapes created in cardiac tissue were in agreement. Amplitude control ablation technology and bipolar ablation technology are feasible methods to create continuous lesion or discrete for pulmonary veins isolation.
Thermal Analysis of Filler Reinforced Polymeric Composites
NASA Astrophysics Data System (ADS)
Ghadge, Mahesh Devidas
Improving heat dissipating property of composite materials is becoming increasingly important in domains ranging from the automotive industry, electronic devices to aeronautical industry. Effective heat dissipation is required especially in aircraft and racing tires to guarantee high performance and good service life [1]. The present study is focused on improving the thermal conductivity of Emulsion-styrene butadiene rubber (ESBR) which is a cheap alternative to other rubber composites. The disadvantages of ESBR are low thermal conductivity and high heat generation. Adding fillers with high thermal conductivity to ESBR is proposed as a technique for improving the thermal conductivity of ESBR. The purpose of the research is to predict the thermal conductivity of ESBR when filled with fillers of much higher thermal conductivity and also to find out to what extent the filler properties affect the heat transfer capabilities of the composite matrix. The influence of different filler shapes i.e. spherical, cylindrical and platelets on the overall thermal capability of composite matrix is studied, the finite element modelings are conducted using Abaqus. Three-dimensional and two-dimensional models are created in Abaqus to simulate the microstructure of the composite matrix filled with fillers. Results indicate that the overall thermal conductivity increases with increasing filler loading i.e. for a filler volume fraction of 0.27, the conductivity increased by around 50%. Filler shapes, orientation angle, and aspect ratio of the fillers significantly influences the thermal conductivity. Conductivity increases with increasing aspect ratio (length/diameter) of the cylindrical fillers since longer conductive chains are able to form at the same volume percentage as compared to spherical fillers. The composite matrix reaches maximum thermal conductivity when the cylindrical fillers are oriented in the direction of heat flow. The heat conductivity predicted by FEM for ESBR is compared with that predicted by mean field theories. At low volume fractions the FEM and mean field theory results are matching. However, at high volume fractions, the results obtained by the two methods are not in agreement. This is due to the fact that mean field theory do not consider the particle interactions happening at higher volume fractions. The present analysis can be used to tailor the thermal properties of ESBR for required thermal conductivity for a wide range of applications such as racing tires, electronic gadgets or aeronautical components. In addition, the proposed FEM models can be used to design and optimize the properties of new composite materials providing more insight into the thermal conductivity of composite polymers and aid in understanding heat transfer mechanism of reinforced polymers.
Diode Laser Excision of Oral Benign Lesions.
Mathur, Ena; Sareen, Mohit; Dhaka, Payal; Baghla, Pallavi
2015-01-01
Lasers have made tremendous progress in the field of dentistry and have turned out to be crucial in oral surgery as collateral approach for soft tissue surgery. This rapid progress can be attributed to the fact that lasers allow efficient execution of soft tissue procedures with excellent hemostasis and field visibility. When matched to scalpel, electrocautery or high frequency devices, lasers offer maximum postoperative patient comfort. Four patients agreed to undergo surgical removal of benign lesions of the oral cavity. 810 nm diode lasers were used in continuous wave mode for excisional biopsy. The specimens were sent for histopathological examination and patients were assessed on intraoperative and postoperative complications. Diode laser surgery was rapid, bloodless and well accepted by patients and led to complete resolution of the lesions. The excised specimen proved adequate for histopathological examination. Hemostasis was achieved immediately after the procedure with minimal postoperative problems, discomfort and scarring. We conclude that diode lasers are rapidly becoming the standard of care in contemporary dental practice and can be employed in procedures requiring excisional biopsy of oral soft tissue lesions with minimal problems in histopathological diagnosis.
Adaptive histogram equalization in digital radiography of destructive skeletal lesions.
Braunstein, E M; Capek, P; Buckwalter, K; Bland, P; Meyer, C R
1988-03-01
Adaptive histogram equalization, an image-processing technique that distributes pixel values of an image uniformly throughout the gray scale, was applied to 28 plain radiographs of bone lesions, after they had been digitized. The non-equalized and equalized digital images were compared by two skeletal radiologists with respect to lesion margins, internal matrix, soft-tissue mass, cortical breakthrough, and periosteal reaction. Receiver operating characteristic (ROC) curves were constructed on the basis of the responses. Equalized images were superior to nonequalized images in determination of cortical breakthrough and presence or absence of periosteal reaction. ROC analysis showed no significant difference in determination of margins, matrix, or soft-tissue masses.
Extraoral sinus tract misdiagnosed as an endodontic lesion.
Cohenca, Nestor; Karni, Sunil; Rotstein, Ilan
2003-12-01
The extraoral sinus tract may occur as a result of an inflammatory process associated with a necrotic pulp. However, several non-odontogenic disorders may also produce an extraoral sinus tract. Thus, the differential diagnosis of this clinical finding is of paramount importance in providing appropriate clinical care because misdiagnosis of this condition may result in healing failure or unnecessary treatment. This case report of a 19-yr-old male patient describes an extraoral cutaneous sinus tract misdiagnosed as an endodontic lesion. Consequently, the patient underwent unnecessary exploratory procedures and antibiotic therapy. Identification of the inflammatory source of the lesion and removal of the affected tissue led to tissue healing.
Glans Penis Augmentation Using Hyaluronic Acid Gel as an Injectable Filler
Kwak, Tae Il; Kim, Je Jong
2015-01-01
Glans penis augmentation (GPA) has received little attention from experts despite the existence of a subset of patients who may be dissatisfied with a small glans or poor tumescence of the glans during erection. Recently, GPA using an injectable filler or implantation of a graft or filler has been developed. Despite a demanding injection technique and inevitable uneven undulation of the glandular surface, GPA using injectable hyaluronic acid (HA) gel is a novel and useful therapy and an effective and safe procedure for soft tissue enhancement. For long-term presence of implants, timed supplementation can be used similar to that for fascial plasty. In complications such as mucosal necrosis of the glans penis, most cases occur from the use of non-HA gel or an unpurified form and misunderstanding of the management protocol for immediate side effects. Currently, GPA using injectable HA gel is not recommended in the International Society for Sexual Medicine guideline due to possible sensory loss. In a 5-year long-term follow-up of GPA by subcutaneous injection of HA gel, the residual volume of implants decreased by 15% of the maximal glandular circumference, but was still effective for alleviating the hypersensitivity of the glans penis in premature ejaculation patients. For efficacy in premature ejaculation, selection of appropriate candidates is the most important factor for success. GPA does not harm erectile function and is less invasive and irreversible compared to dorsal neurectomy. To refine the procedure, more interest and well-designed studies are required for the establishment of the procedure. PMID:26331121
Glans Penis Augmentation Using Hyaluronic Acid Gel as an Injectable Filler.
Moon, Du Geon; Kwak, Tae Il; Kim, Je Jong
2015-08-01
Glans penis augmentation (GPA) has received little attention from experts despite the existence of a subset of patients who may be dissatisfied with a small glans or poor tumescence of the glans during erection. Recently, GPA using an injectable filler or implantation of a graft or filler has been developed. Despite a demanding injection technique and inevitable uneven undulation of the glandular surface, GPA using injectable hyaluronic acid (HA) gel is a novel and useful therapy and an effective and safe procedure for soft tissue enhancement. For long-term presence of implants, timed supplementation can be used similar to that for fascial plasty. In complications such as mucosal necrosis of the glans penis, most cases occur from the use of non-HA gel or an unpurified form and misunderstanding of the management protocol for immediate side effects. Currently, GPA using injectable HA gel is not recommended in the International Society for Sexual Medicine guideline due to possible sensory loss. In a 5-year long-term follow-up of GPA by subcutaneous injection of HA gel, the residual volume of implants decreased by 15% of the maximal glandular circumference, but was still effective for alleviating the hypersensitivity of the glans penis in premature ejaculation patients. For efficacy in premature ejaculation, selection of appropriate candidates is the most important factor for success. GPA does not harm erectile function and is less invasive and irreversible compared to dorsal neurectomy. To refine the procedure, more interest and well-designed studies are required for the establishment of the procedure.
Body Image, Personality Traits, and Quality of Life in Botulinum Toxin A and Dermal Filler Patients.
Scharschmidt, Dagmar; Mirastschijski, Ursula; Preiss, Simone; Brähler, Elmar; Fischer, Tanja; Borkenhagen, A
2018-06-11
The demand for minimally invasive cosmetic procedures has continued to rise, especially in Germany, yet few studies have examined this patient population. The literature in Germany has repeatedly voiced the speculation that users of minimally invasive, skin-rejuvenating procedures displayed a higher tendency toward dysmorphic behavior patterns or, respectively, other abnormal personality traits. The aim of this study was to investigate body image, personality traits, quality of life, and socioeconomic parameters in users of botulinum toxin and/or facial fillers. One hundred forty-five females presented for botulinum toxin and/or soft tissue filler injections completed demographic and standardized psychometric questionnaires such as the World-Health-Organization Quality of Life-Short Form, Big Five Inventory-10, Body Dysmorphic Disorder Questionnaire before treatment. Patients undergoing injectable aesthetic treatments in an urban dermatology practice were women, middle-aged, highly educated, and mostly employed. Furthermore, participants showed higher quality of life, especially health-related quality of life, and a lower body mass index than controls. Concerning personality traits, our participants scored significantly higher on extraversion, agreeableness, openness to experience, and neuroticism. This study helps to better understand the psychosocial factors characterizing this patient population. Patients differ from controls by having a higher level of quality of life. No signs of body dysmorphic patterns or problematic personality traits were found. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .