4 CFR 201.17 - How to track a FOIA request.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 4 Accounts 1 2010-01-01 2010-01-01 false How to track a FOIA request. 201.17 Section 201.17 Accounts RECOVERY ACCOUNTABILITY AND TRANSPARENCY BOARD PUBLIC INFORMATION AND REQUESTS § 201.17 How to track a FOIA request. (a) Tracking number. The Board will issue a tracking number to all FOIA requesters...
32 CFR 701.8 - Processing FOIA requests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... queues as they wish, however, at a minimum three processing tracks shall be established, all based on a... simple requests, one track for complex requests, and one track for expedited processing. Determinations as to whether a request is simple or complex shall be made by each DON activity. (2) DON activities...
Maintaining clinical tissue archives and supporting human research: challenges and solutions.
Giannini, Caterina; Oelkers, Michael M; Edwards, William D; Aubry, Marie Christine; Muncil, Maureen M; Mohamud, Koshin H; Sandleback, Sara G; Nowak, John M; Bridgeman, Andrew; Brown, Marie E; Cheville, John C
2011-03-01
The increasing number of requests for use of clinically archived tissue in translational research poses unique challenges. Conflicts may arise between pathologists who are responsible for overseeing and preserving the tissues and investigators who need these materials for research purposes. To evaluate the status of our institution's Tissue Registry Archive and to develop updated written policies and procedures to support a new modern and robust tracking system with features of a library loan system. An observational study was performed. We found the existing process for managing loans of tissue (slides and paraffin blocks) to be insufficient for the complexity and volume of this task. After extensive customization, a new tracking system was implemented in January 2008. Analysis of the first year of the system's use (2008) showed that of the 206,330 slides and 51,416 blocks loaned out in 2008, 92% and 94%, respectively, were returned by the due date. These rates were markedly improved from those before the new system: 61% and 47%, respectively, in 2005. Material permanently "lost" in 2008 represented only 0.02% of slides and 0.05% of blocks, none of which was the only diagnostic material for the case. With expanding needs for archived tissues for clinical care and growing demands for translational research, it is essential that pathology departments at institutions with large tissue-based research endeavors have a tracking and management system in place to meet clinical, educational, and research needs, as well as legal requirements.
39 CFR 3004.42 - Tracking of requests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 39 Postal Service 1 2011-07-01 2011-07-01 false Tracking of requests. 3004.42 Section 3004.42 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL PUBLIC RECORDS AND FREEDOM OF INFORMATION ACT... that number to the person making the request. (b) Any person with a tracking number may call or e-mail...
39 CFR 3004.42 - Tracking of requests.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Tracking of requests. 3004.42 Section 3004.42 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL PUBLIC RECORDS AND FREEDOM OF INFORMATION ACT... that number to the person making the request. (b) Any person with a tracking number may call or e-mail...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
12 CFR 261.13 - Processing requests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Information Office and that have already been cleared for public release may qualify for fast-track processing... will make the determination whether a request qualifies for fast-track processing. A requester may contact the Freedom of Information Office to learn whether a particular request has been assigned to fast...
6 CFR 5.5 - Timing of responses to requests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the number of pages involved. If a component does so, it shall advise requesters in its slower track(s...) Requests and appeals will be taken out of order and given expedited treatment whenever it is determined...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2012 CFR
2012-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2010 CFR
2010-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2013 CFR
2013-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2014 CFR
2014-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
12 CFR 792.10 - What will NCUA do with my request?
Code of Federal Regulations, 2011 CFR
2011-01-01
... identifiable by the Information Center and have already been cleared for public release may qualify for fast... received. (c) The Information Center will make the determination whether a request qualifies for fast track... request has been assigned. If your request has not qualified for fast track processing, you will have an...
29 CFR 70.25 - Time limits and order in which requests must be processed.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pages involved. If a component does so, it will advise requesters in its slower track(s) of the limits... unrelated matters will not be aggregated. (d) Expedited processing. (1) Requests and appeals will be taken...
29 CFR 70.25 - Time limits and order in which requests must be processed.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pages involved. If a component does so, it will advise requesters in its slower track(s) of the limits... unrelated matters will not be aggregated. (d) Expedited processing. (1) Requests and appeals will be taken...
29 CFR 70.25 - Time limits and order in which requests must be processed.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pages involved. If a component does so, it will advise requesters in its slower track(s) of the limits... unrelated matters will not be aggregated. (d) Expedited processing. (1) Requests and appeals will be taken...
Structural requirements of research tissue banks derived from standardized project surveillance.
Herpel, E; Koleganova, N; Schreiber, B; Walter, B; Kalle, C V; Schirmacher, P
2012-07-01
Tissue banks constitute decisive and rate-limiting resource and technology platforms for basic and translational biomedical research, notably in the area of cancer. Thus, it is essential to plan and structure tissue banking and allocate resources according to research needs, but essential requirements are still incompletely defined. The tissue bank of the National Center of Tumor Diseases Heidelberg (NCT) was founded with the intention to provide tissues of optimal quality and to prioritize the realization of research projects. We analysed its structure and prospective project management registration as well as tracking records for all projects of the NCT tissue bank as of its start in 2005 in order to obtain information that may be relevant for tissue bank planning. All project proposals submitted to the NCT tissue bank (n = 681) were included in the study. For a detailed evaluation of provided services, only projects that were completed until July 2011 (n = 605) were analysed. For these 605 projects, NCT tissue bank provided 769 specific services. In all projects/services, we recorded project leader, type and amount of material provided, type of research (basic/translational), work load of project and project completion. Furthermore, all completed projects were tracked after 90 days according to a standard protocol to determine principal investigators' (PI) satisfaction and quality of the provided material. Until July 2011, 605 projects had been successfully completed as documented by material transfer agreement. Of the projects, 72.7 % addressed basic research, 22.3 % were translational research projects and 3 % concerned epidemiological research; 91 % (n = 546) concerned a single PI and the NTC tissue bank. For these projects, 769 specific services were provided. Of these services, 288 concerned providing formalin-fixed and paraffin-embedded (FFPE) tissue (extracts, full size sections), 126 providing fresh frozen materials (including fresh frozen sections), 137 providing tissue micro-array (TMA)-based sections and 199 providing immunohistochemical services. Project tracking demonstrated that all projects had started within 90 days after reception of the material by the PIs, and PI satisfaction with provided material exceeded 97 %. Standardized registration and tracking provides valuable structural information for planning and financing of tissue banks and allocation of resources. The high number of completed projects as well as high user satisfaction demonstrates that structuring of tissue banks should be preferably research-oriented and highly efficient. The comparable number of requests for FFPE and fresh frozen tissue as well as TMA-based services underpins the need for a broad approach in terms of methods and material types in order to fulfil research needs.
40 CFR 270.42 - Permit modification at the request of the permittee.
Code of Federal Regulations, 2014 CFR
2014-07-01
... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...
40 CFR 270.42 - Permit modification at the request of the permittee.
Code of Federal Regulations, 2011 CFR
2011-07-01
... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...
40 CFR 270.42 - Permit modification at the request of the permittee.
Code of Federal Regulations, 2013 CFR
2013-07-01
... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...
40 CFR 270.42 - Permit modification at the request of the permittee.
Code of Federal Regulations, 2012 CFR
2012-07-01
... storage in tanks or containers, or in containment buildings in accordance with 40 CFR part 268; (C) To...) Performance Track member facilities. The following procedures apply to Performance Track member facilities... Track member facilities must have complied with the requirements of § 264.15(b)(5) in order to request a...
Unbiased and unnoticed verbal conditioning: the double agent robot procedure1
Rosenfeld, Howard M.; Baer, Donald M.
1970-01-01
Subjects who were told they were “experimenters” attempted to reinforce fluent speech in a supposed subject with whom they spoke via intercom. The supposed subject was to say nouns, one at a time, on request by the “experimenter”, who reinforced fluent pronunciation with points. Actually, the “experimenter” was talking to a multi-track tape recording, one track of which contained fluently spoken nouns, the other track containing disfluently spoken nouns. If the “experimenter's” request for the next noun was in a specified form a word from the fluent track was played to him as reinforcement; requests in any other form produced the word from the disfluent track. Repeated conditioning of specific forms of requests was accomplished with two subject-“experimenters,” who were unable to describe changes in their own behavior, or the contingencies applied. This technique improved upon an earlier method that had yielded similar results, but was less thoroughly controlled against possible human bias. PMID:16811461
Evaluating OpenSHMEM Explicit Remote Memory Access Operations and Merged Requests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boehm, Swen; Pophale, Swaroop S; Gorentla Venkata, Manjunath
The OpenSHMEM Library Specification has evolved consid- erably since version 1.0. Recently, non-blocking implicit Remote Memory Access (RMA) operations were introduced in OpenSHMEM 1.3. These provide a way to achieve better overlap between communication and computation. However, the implicit non-blocking operations do not pro- vide a separate handle to track and complete the individual RMA opera- tions. They are guaranteed to be completed after either a shmem quiet(), shmem barrier() or a shmem barrier all() is called. These are global com- pletion and synchronization operations. Though this semantic is expected to achieve a higher message rate for the applications, themore » drawback is that it does not allow fine-grained control over the completion of RMA operations. In this paper, first, we introduce non-blocking RMA operations with requests, where each operation has an explicit request to track and com- plete the operation. Second, we introduce interfaces to merge multiple requests into a single request handle. The merged request tracks multiple user-selected RMA operations, which provides the flexibility of tracking related communication operations with one request handle. Lastly, we explore the implications in terms of performance, productivity, usability and the possibility of defining different patterns of communication via merging of requests. Our experimental results show that a well designed and implemented OpenSHMEM stack can hide the overhead of allocating and managing the requests. The latency of RMA operations with requests is similar to blocking and implicit non-blocking RMA operations. We test our implementation with the Scalable Synthetic Compact Applications (SSCA #1) benchmark and observe that using RMA operations with requests and merging of these requests outperform the implementation using blocking RMA operations and implicit non-blocking operations by 49% and 74% respectively.« less
The interpersonal process in tissue donation requests with “undecided” next of kin
Dorflinger, Lindsey; Auerbach, Stephen M.; Siminoff, Laura A.
2012-01-01
Context Although recent studies have demonstrated that tissue requesters’ behavior during conversations about tissue donation affects consent rates, the link between requesters’ behavior and consent rates remains unclear. Objective To examine whether positive/collaborative requester behaviors elicit complementary behaviors from next of kin who were initially undecided about their willingness to donate their deceased family member’s tissues. Design Audio recordings of requests were coded to assess for interpersonal behavior of each interactant. Setting Audio recordings were gathered from a national sample of tissue banks. Participants One hundred and two requester–next-of-kin dyads, consisting of 102 relatives and 53 requesters. Main Outcome Measures Tissue requester and next-of-kin affiliation and interpersonal control were assessed. Tissue requesters’ persuasion, confirmation (eg, approval, empathy, reassurance) and disapproval, as well as next-of-kin approval and disapproval, were examined. Results Tissue requesters and next of kin tended to match one another on affiliation and complement one another on interpersonal control. “Key topics,” which may affect the next of kin’s decision, are discussed in only about one-third of requests. Next of kin were less affiliative and more disapproving when requesters were also more disapproving. Interpersonal behavior of the tissue requester, such as affiliation, statements of disapproval, and persuasion, as well as discussion of key topics, was a significant predictor of the interpersonal behavior of the next of kin. Conclusions Positive requester behaviors elicited a positive response from undecided next of kin. Because many next of kin have limited knowledge about tissue donation before the request, the communication process may affect the next of kin’s perceptions of donation and thus affect the likelihood of consent. Findings could potentially inform communication skills training for tissue requesters; future research could examine effects of such training on consent rates. PMID:23187062
NASA Technical Reports Server (NTRS)
Clement, Bradley; Johnston, Mark; Wax, Allan; Chouinard, Caroline
2008-01-01
The DSN (Deep Space Network) Scheduling Engine targets all space missions that use DSN services. It allows clients to issue scheduling, conflict identification, conflict resolution, and status requests in XML over a Java Message Service interface. The scheduling requests may include new requirements that represent a set of tracks to be scheduled under some constraints. This program uses a heuristic local search to schedule a variety of schedule requirements, and is being infused into the Service Scheduling Assembly, a mixed-initiative scheduling application. The engine resolves conflicting schedules of resource allocation according to a range of existing and possible requirement specifications, including optional antennas; start of track and track duration ranges; periodic tracks; locks on track start, duration, and allocated antenna; MSPA (multiple spacecraft per aperture); arraying/VLBI (very long baseline interferometry)/delta DOR (differential one-way ranging); continuous tracks; segmented tracks; gap-to-track ratio; and override or block-out of requirements. The scheduling models now include conflict identification for SOA(start of activity), BOT (beginning of track), RFI (radio frequency interference), and equipment constraints. This software will search through all possible allocations while providing a best-effort solution at any time. The engine reschedules to accommodate individual emergency tracks in 0.2 second, and emergency antenna downtime in 0.2 second. The software handles doubling of one mission's track requests over one week (to 42 total) in 2.7 seconds. Further tests will be performed in the context of actual schedules.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-18
... request is entered into the appropriate tracking databases. Use of the information in the Agency's tracking databases enables the appropriate Agency official to monitor progress on the evaluation of the... collection of information on respondents, including through the use of automated collection techniques, when...
75 FR 47029 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-04
... currently approved information collection used by customers/researchers for ordering reproductions of NARA's... bodies of records. NARA uses the Item Approval Request List form to track reproduction requests and to...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... questioned whether the processing fee was required only if early publication was requested. Response: Both... fee for requesting early publication. Comment 5: A few comments indicated that the fee for prioritized... applicant being unable to amend the claims to place them in independent form after a final rejection where...
A Biocompatible Near-Infrared 3D Tracking System*
Decker, Ryan S.; Shademan, Azad; Opfermann, Justin D.; Leonard, Simon; Kim, Peter C. W.; Krieger, Axel
2017-01-01
A fundamental challenge in soft-tissue surgery is that target tissue moves and deforms, becomes occluded by blood or other tissue, and is difficult to differentiate from surrounding tissue. We developed small biocompatible near-infrared fluorescent (NIRF) markers with a novel fused plenoptic and NIR camera tracking system, enabling 3D tracking of tools and target tissue while overcoming blood and tissue occlusion in the uncontrolled, rapidly changing surgical environment. In this work, we present the tracking system and marker design and compare tracking accuracies to standard optical tracking methods using robotic experiments. At speeds of 1 mm/s, we observe tracking accuracies of 1.61 mm, degrading only to 1.71 mm when the markers are covered in blood and tissue. PMID:28129145
Biocompatible Near-Infrared Three-Dimensional Tracking System.
Decker, Ryan S; Shademan, Azad; Opfermann, Justin D; Leonard, Simon; Kim, Peter C W; Krieger, Axel
2017-03-01
A fundamental challenge in soft-tissue surgery is that target tissue moves and deforms, becomes occluded by blood or other tissue, and is difficult to differentiate from surrounding tissue. We developed small biocompatible near-infrared fluorescent (NIRF) markers with a novel fused plenoptic and NIR camera tracking system, enabling three-dimensional tracking of tools and target tissue while overcoming blood and tissue occlusion in the uncontrolled, rapidly changing surgical environment. In this work, we present the tracking system and marker design and compare tracking accuracies to standard optical tracking methods using robotic experiments. At speeds of 1 mm/s, we observe tracking accuracies of 1.61 mm, degrading only to 1.71 mm when the markers are covered in blood and tissue.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... Submitted to OMB for Review and Approval: Comment Request; Great Lakes Accountability System (Reinstatement... Agency has submitted an information collection request (ICR), Great Lakes Accountability System... legislation called for increased accountability for the GLRI and directed EPA to implement a process to track...
32 CFR 701.8 - Processing FOIA requests.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Control FOIA Request. Each FOIA request should be date stamped upon receipt; given a case number; and entered into a formal control system to track the request from receipt to response. Coordinators may wish... in mind a test for reasonableness (i.e., file disposition requirements set forth in SECNAVINST 5212...
32 CFR 701.8 - Processing FOIA requests.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Control FOIA Request. Each FOIA request should be date stamped upon receipt; given a case number; and entered into a formal control system to track the request from receipt to response. Coordinators may wish... in mind a test for reasonableness (i.e., file disposition requirements set forth in SECNAVINST 5212...
32 CFR 701.8 - Processing FOIA requests.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Control FOIA Request. Each FOIA request should be date stamped upon receipt; given a case number; and entered into a formal control system to track the request from receipt to response. Coordinators may wish... in mind a test for reasonableness (i.e., file disposition requirements set forth in SECNAVINST 5212...
32 CFR 1700.7 - Processing of requests for records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of Information Act Request.” (b) Electronic Reading Room. ODNI maintains an online FOIA Reading Room... limit the scope of their requests in order to qualify for faster processing within the specified limits of its faster track. ...
32 CFR 1700.7 - Processing of requests for records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of Information Act Request.” (b) Electronic Reading Room. ODNI maintains an online FOIA Reading Room... limit the scope of their requests in order to qualify for faster processing within the specified limits of its faster track. ...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2012 CFR
2012-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2011 CFR
2011-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2010 CFR
2010-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires expeditious resolution. Fast Track procedures may include expedited...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
... Procedures for Grant Payment Request Submission. OMB Control Number: XXXX-XXXX. Type of Request: New... Administrations (OAs).\\1\\ DOT is updating systems that support grant payments and there will be changes to the way... requesting payment electronically through the National Highway Traffic Safety Administration's Grant Tracking...
McDonald, Sandra A; Ryan, Benjamin J; Brink, Amy; Holtschlag, Victoria L
2012-02-01
Informatics systems, particularly those that provide capabilities for data storage, specimen tracking, retrieval, and order fulfillment, are critical to the success of biorepositories and other laboratories engaged in translational medical research. A crucial item-one easily overlooked-is an efficient way to receive and process investigator-initiated requests. A successful electronic ordering system should allow request processing in a maximally efficient manner, while also allowing streamlined tracking and mining of request data such as turnaround times and numerical categorizations (user groups, funding sources, protocols, and so on). Ideally, an electronic ordering system also facilitates the initial contact between the laboratory and customers, while still allowing for downstream communications and other steps toward scientific partnerships. We describe here the recently established Web-based ordering system for the biorepository at Washington University Medical Center, along with its benefits for workflow, tracking, and customer service. Because of the system's numerous value-added impacts, we think our experience can serve as a good model for other customer-focused biorepositories, especially those currently using manual or non-Web-based request systems. Our lessons learned also apply to the informatics developers who serve such biobanks.
Ryan, Benjamin J.; Brink, Amy; Holtschlag, Victoria L.
2012-01-01
Informatics systems, particularly those that provide capabilities for data storage, specimen tracking, retrieval, and order fulfillment, are critical to the success of biorepositories and other laboratories engaged in translational medical research. A crucial item—one easily overlooked—is an efficient way to receive and process investigator-initiated requests. A successful electronic ordering system should allow request processing in a maximally efficient manner, while also allowing streamlined tracking and mining of request data such as turnaround times and numerical categorizations (user groups, funding sources, protocols, and so on). Ideally, an electronic ordering system also facilitates the initial contact between the laboratory and customers, while still allowing for downstream communications and other steps toward scientific partnerships. We describe here the recently established Web-based ordering system for the biorepository at Washington University Medical Center, along with its benefits for workflow, tracking, and customer service. Because of the system's numerous value-added impacts, we think our experience can serve as a good model for other customer-focused biorepositories, especially those currently using manual or non-Web–based request systems. Our lessons learned also apply to the informatics developers who serve such biobanks. PMID:23386921
43 CFR 2.26 - Does the bureau provide multitrack processing of FOIA requests?
Code of Federal Regulations, 2010 CFR
2010-10-01
... process the request. FOIA requests will be placed in one of the following tracks: (1) Simple: 1-5 workdays... the Department's FOIA home page at http://www.doi.gov/foia/policy.html for details. [74 FR 17092, Apr...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-13
...: Fast Track Drug Development Programs: Designation, Development, and Application Review AGENCY: Food and... licenses for fast track designation as provided in the guidance for industry on fast track drug development... appropriate, and other forms of information technology. Guidance for Industry: Fast Track Drug Development...
Reasonable Accommodation Information Tracking System
The Reasonable Accommodation Information Tracking System (RAITS) is a case management system that allows the National Reasonable Accommodation Coordinator (NRAC) and the Local Reasonable Accommodation Coordinators (LORAC) to manage information related to Reasonable Accommodation (RA) requests. It provides a data base system in compliance with Executive Order 13164 and required by the Equal Employment Opportunity Commission (EEOC) Regulations and American Federation of Government Employees (AFGE) Bargaining Unit as described in the AFGE National Reasonable Accommodation Procedures. It is a tool that was internally developed in Lotus Notes to track requests for reasonable accommodation and was custom-configured to meet EPA's specific needs and infrastructure.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-22
... Collection; Comments Requested: Drug Endangered Children Tracking System User Survey ACTION: 60-day notice... technological collection techniques or other forms of information technology, e.g., permitting electronic... new collection; comments requested. (2) Title of the Form/Collection: Drug Endangered Children...
75 FR 7268 - Agency Information Collection Request; 60-Day Public Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-18
... information collection request for public comment. Interested persons are invited to send comments regarding... plans, employers, and health care providers. We know very little about why consumers, and specifically... the newer, more robust Internet-based tools for tracking their health and health care services. This...
7 CFR 510.4 - Multitrack processing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AGRICULTURE PUBLIC INFORMATION § 510.4 Multitrack processing. (a) When ARS has a significant number of... involved in processing the request, and whether the request qualifies for expedited processing. (b) ARS may... possible. (d) ARS shall process requests in each track on a “first-in, first-out” basis, unless there are...
7 CFR 510.4 - Multitrack processing.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AGRICULTURE PUBLIC INFORMATION § 510.4 Multitrack processing. (a) When ARS has a significant number of... involved in processing the request, and whether the request qualifies for expedited processing. (b) ARS may... possible. (d) ARS shall process requests in each track on a “first-in, first-out” basis, unless there are...
7 CFR 510.4 - Multitrack processing.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AGRICULTURE PUBLIC INFORMATION § 510.4 Multitrack processing. (a) When ARS has a significant number of... involved in processing the request, and whether the request qualifies for expedited processing. (b) ARS may... possible. (d) ARS shall process requests in each track on a “first-in, first-out” basis, unless there are...
7 CFR 510.4 - Multitrack processing.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AGRICULTURE PUBLIC INFORMATION § 510.4 Multitrack processing. (a) When ARS has a significant number of... involved in processing the request, and whether the request qualifies for expedited processing. (b) ARS may... possible. (d) ARS shall process requests in each track on a “first-in, first-out” basis, unless there are...
7 CFR 510.4 - Multitrack processing.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AGRICULTURE PUBLIC INFORMATION § 510.4 Multitrack processing. (a) When ARS has a significant number of... involved in processing the request, and whether the request qualifies for expedited processing. (b) ARS may... possible. (d) ARS shall process requests in each track on a “first-in, first-out” basis, unless there are...
40 CFR 1068.501 - How do I report emission-related defects?
Code of Federal Regulations, 2010 CFR
2010-07-01
... methods for tracking, investigating, reporting, and correcting emission-related defects. In your request... aggregate in tracking, identifying, investigating, evaluating, reporting, and correcting potential and... it is actually defective. Note that this paragraph (b)(2) does not require data-tracking or recording...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-03
... Collection; Comment Request; Protocol for Access to Tissue Specimen Samples From the National Marine Mammal Tissue Bank AGENCY: National Oceanic and Atmospheric Administration (NOAA), Commerce. ACTION: Notice... National Marine Mammal Tissue Bank (NMMTB) was established by the National Marine Fisheries Service (NMFS...
ERIC Educational Resources Information Center
Megaridis, Crystal S.
Work request statistics have been tracked at the Praxair Information Resource Center (IRC) for nearly a decade. After a gradual and steady increase of work requests over the years, the work requested of the IRC reached a plateau in 1999 that lasted approximately 1 year. Work request statistics during the winter of 2000, however, indicated a shift…
15 CFR 4.6 - Time limits and expedited processing.
Code of Federal Regulations, 2014 CFR
2014-01-01
... tracks by distinguishing between simple and more complex requests based on the number of pages involved...) Expedited processing. (1) Requests and appeals shall be taken out of order and given expedited treatment...
32 CFR 1701.7 - Requests for notification of and access to records.
Code of Federal Regulations, 2011 CFR
2011-07-01
... THE DIRECTOR OF NATIONAL INTELLIGENCE ADMINISTRATION OF RECORDS UNDER THE PRIVACY ACT OF 1974 Protection of Privacy and Access to Individual Records Under the Privacy Act of 1974 § 1701.7 Requests for... the specific Privacy Act System of Records Notice. To ensure proper routing and tracking, requesters...
77 FR 27151 - Implementing the Freedom of Information Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-09
... e-FOIA Reading Room. OSTP shall make records available on its Web site in accordance with 5 U.S.C... review documents available at the OSTP e-FOIA Reading Room before submitting a request. (c) Definitions... qualify for faster processing. (2) Complex requests. The second track is for requests involving ``unusual...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-20
.... Method of Collection Requests from allocation holders to transfer quota use paper applications or an... submitted on or before December 19, 2011. ADDRESSES: Direct all written comments to Diana Hynek... transferable quota (ITQ) allocation holders in order to process and track requests from the allocation holders...
The role of "rescue saccades" in tracking objects through occlusions.
Zelinsky, Gregory J; Todor, Andrei
2010-12-29
We hypothesize that our ability to track objects through occlusions is mediated by timely assistance from gaze in the form of "rescue saccades"-eye movements to tracked objects that are in danger of being lost due to impending occlusion. Observers tracked 2-4 target sharks (out of 9) for 20 s as they swam through a rendered 3D underwater scene. Targets were either allowed to enter into occlusions (occlusion trials) or not (no occlusion trials). Tracking accuracy with 2-3 targets was ≥ 92% regardless of target occlusion but dropped to 74% on occlusion trials with four targets (no occlusion trials remained accurate; 83%). This pattern was mirrored in the frequency of rescue saccades. Rescue saccades accompanied approximatlely 50% of the Track 2-3 target occlusions, but only 34% of the Track 4 occlusions. Their frequency also decreased with increasing distance between a target and the nearest other object, suggesting that it is the potential for target confusion that summons a rescue saccade, not occlusion itself. These findings provide evidence for a tracking system that monitors for events that might cause track loss (e.g., occlusions) and requests help from the oculomotor system to resolve these momentary crises. As the number of crises increase with the number of targets, some requests for help go unsatisfied, resulting in degraded tracking.
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2014 CFR
2014-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
18 CFR 385.206 - Complaints (Rule 206).
Code of Federal Regulations, 2013 CFR
2013-04-01
... electronic media as specified by the Secretary. (11) Explain with respect to requests for Fast Track... merits based upon the pleadings; (3) The Commission may establish a hearing before an ALJ; (h) Fast Track processing. (1) The Commission may resolve complaints using Fast Track procedures if the complaint requires...
78 FR 12825 - Petition for Extension of Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... the frequency of the required visual track inspections. FRA issued the initial waiver that granted.... SEPTA requests an extension of approval to reduce the frequency of required, visual track inspections... with continuous welded rail. SEPTA proposes to conduct one visual track inspection per week, instead of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-24
... Third-Grade National Collection, Fourth-Grade Recruitment, and Fifth-Grade Tracking AGENCY: Department...-Grade Recruitment, and Fifth-Grade Tracking. OMB Control Number: 1850-0790. Type of Review: Revision of...) recruitment for the spring 2015 fourth-grade data collection, and (3) tracking students for the spring 2016...
77 FR 53164 - Railroad Workplace Safety; Adjacent-Track On-Track Safety for Roadway Workers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-31
...-0059, Notice No. 6] RIN 2130-AC37 Railroad Workplace Safety; Adjacent-Track On-Track Safety for Roadway... complex issues raised in both the petitions for reconsideration of the final rule published November 30... issues. One of the Petitions included a request for a delay in the effective date of the final rule until...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... the appropriate tracking databases. Use of the information in the Agency's tracking databases enables... of information on respondents, including through the use of automated collection techniques, when...
40 CFR 1601.24 - Timing of responses to requests.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of pages involved. If the agency does so, it shall advise requesters assigned to its slower track of... appeals will be taken out of order and given expedited treatment whenever it is determined that they...
40 CFR 1601.24 - Timing of responses to requests.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of pages involved. If the agency does so, it shall advise requesters assigned to its slower track of... appeals will be taken out of order and given expedited treatment whenever it is determined that they...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-13
... entered into the appropriate tracking databases. Use of the information in the agency's tracking databases... respondents, including through the use of automated collection techniques, when appropriate, and other forms...
77 FR 13978 - Railroad Workplace Safety; Adjacent-Track On-Track Safety for Roadway Workers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-08
... rule; delay of effective date and request for comments. SUMMARY: This document delays the effective date of the final rule published November 30, 2011, and scheduled to take effect on May 1, 2012. The final rule mandates that roadway workers comply with specified on-track safety procedures that railroads...
75 FR 21250 - Privacy Act of 1974; Systems of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-23
... information of the current tenants of NSA/CSS facilities; to create and track the status of visit requests and... facility; to track inside the NSA/CSS facility authorized NSA/CSS employee and visitor badges as they are used to pass through automated turnstile system, access office suites and other work areas; to track...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-28
... Request; Guidance for Industry: Fast Track Drug Development Programs: Designation, Development, and... information to OMB for review and clearance. Guidance for Industry: Fast Track Drug Development Programs... to industry on fast track policies and procedures outlined in section 506 of the FD&C Act. The...
12 CFR 1202.7 - How will FHFA respond to my FOIA request?
Code of Federal Regulations, 2010 CFR
2010-01-01
... order in which they are received. If FHFA determines while processing your Standard Track request, that... expedited delivery service fees or to pick up records at our office. (f) Extensions of Time. In unusual...
12 CFR 1202.7 - How will FHFA respond to my FOIA request?
Code of Federal Regulations, 2011 CFR
2011-01-01
... order in which they are received. If FHFA determines while processing your Standard Track request, that... expedited delivery service fees or to pick up records at our office. (f) Extensions of Time. In unusual...
Robust cell tracking in epithelial tissues through identification of maximum common subgraphs.
Kursawe, Jochen; Bardenet, Rémi; Zartman, Jeremiah J; Baker, Ruth E; Fletcher, Alexander G
2016-11-01
Tracking of cells in live-imaging microscopy videos of epithelial sheets is a powerful tool for investigating fundamental processes in embryonic development. Characterizing cell growth, proliferation, intercalation and apoptosis in epithelia helps us to understand how morphogenetic processes such as tissue invagination and extension are locally regulated and controlled. Accurate cell tracking requires correctly resolving cells entering or leaving the field of view between frames, cell neighbour exchanges, cell removals and cell divisions. However, current tracking methods for epithelial sheets are not robust to large morphogenetic deformations and require significant manual interventions. Here, we present a novel algorithm for epithelial cell tracking, exploiting the graph-theoretic concept of a 'maximum common subgraph' to track cells between frames of a video. Our algorithm does not require the adjustment of tissue-specific parameters, and scales in sub-quadratic time with tissue size. It does not rely on precise positional information, permitting large cell movements between frames and enabling tracking in datasets acquired at low temporal resolution due to experimental constraints such as phototoxicity. To demonstrate the method, we perform tracking on the Drosophila embryonic epidermis and compare cell-cell rearrangements to previous studies in other tissues. Our implementation is open source and generally applicable to epithelial tissues. © 2016 The Authors.
Robust cell tracking in epithelial tissues through identification of maximum common subgraphs
Bardenet, Rémi; Zartman, Jeremiah J.; Baker, Ruth E.
2016-01-01
Tracking of cells in live-imaging microscopy videos of epithelial sheets is a powerful tool for investigating fundamental processes in embryonic development. Characterizing cell growth, proliferation, intercalation and apoptosis in epithelia helps us to understand how morphogenetic processes such as tissue invagination and extension are locally regulated and controlled. Accurate cell tracking requires correctly resolving cells entering or leaving the field of view between frames, cell neighbour exchanges, cell removals and cell divisions. However, current tracking methods for epithelial sheets are not robust to large morphogenetic deformations and require significant manual interventions. Here, we present a novel algorithm for epithelial cell tracking, exploiting the graph-theoretic concept of a ‘maximum common subgraph’ to track cells between frames of a video. Our algorithm does not require the adjustment of tissue-specific parameters, and scales in sub-quadratic time with tissue size. It does not rely on precise positional information, permitting large cell movements between frames and enabling tracking in datasets acquired at low temporal resolution due to experimental constraints such as phototoxicity. To demonstrate the method, we perform tracking on the Drosophila embryonic epidermis and compare cell–cell rearrangements to previous studies in other tissues. Our implementation is open source and generally applicable to epithelial tissues. PMID:28334699
NASA Technical Reports Server (NTRS)
Wang, Yeou-Fang; Baldwin, John
2007-01-01
TIGRAS is client-side software, which provides tracking-station equipment planning, allocation, and scheduling services to the DSMS (Deep Space Mission System). TIGRAS provides functions for schedulers to coordinate the DSN (Deep Space Network) antenna usage time and to resolve the resource usage conflicts among tracking passes, antenna calibrations, maintenance, and system testing activities. TIGRAS provides a fully integrated multi-pane graphical user interface for all scheduling operations. This is a great improvement over the legacy VAX VMS command line user interface. TIGRAS has the capability to handle all DSN resource scheduling aspects from long-range to real time. TIGRAS assists NASA mission operations for DSN tracking of station equipment resource request processes from long-range load forecasts (ten years or longer), to midrange, short-range, and real-time (less than one week) emergency tracking plan changes. TIGRAS can be operated by NASA mission operations worldwide to make schedule requests for the DSN station equipment.
Acquire: an open-source comprehensive cancer biobanking system.
Dowst, Heidi; Pew, Benjamin; Watkins, Chris; McOwiti, Apollo; Barney, Jonathan; Qu, Shijing; Becnel, Lauren B
2015-05-15
The probability of effective treatment of cancer with a targeted therapeutic can be improved for patients with defined genotypes containing actionable mutations. To this end, many human cancer biobanks are integrating more tightly with genomic sequencing facilities and with those creating and maintaining patient-derived xenografts (PDX) and cell lines to provide renewable resources for translational research. To support the complex data management needs and workflows of several such biobanks, we developed Acquire. It is a robust, secure, web-based, database-backed open-source system that supports all major needs of a modern cancer biobank. Its modules allow for i) up-to-the-minute 'scoreboard' and graphical reporting of collections; ii) end user roles and permissions; iii) specimen inventory through caTissue Suite; iv) shipping forms for distribution of specimens to pathology, genomic analysis and PDX/cell line creation facilities; v) robust ad hoc querying; vi) molecular and cellular quality control metrics to track specimens' progress and quality; vii) public researcher request; viii) resource allocation committee distribution request review and oversight and ix) linkage to available derivatives of specimen. © The Author 2015. Published by Oxford University Press.
An expert system for scheduling requests for communications Links between TDRSS and ERBS
NASA Technical Reports Server (NTRS)
Mclean, David R.; Littlefield, Ronald G.; Beyer, David S.
1987-01-01
An ERBS-TDRSS Contact Planning System (ERBS-TDRSS CPS) is described which uses a graphics interface and the NASA Transportable Interference Engine. The procedure involves transfer of the ERBS-TDRSS Ground Track Orbit Prediction data to the ERBS flight operations area, where the ERBS-TDRSS CPS automatically generates requests for TDRSS service. As requested events are rejected, alternative context sensitive strategies are employed to generate new requested events until a schedule is completed. A report generator builds schedule requests for separate ERBS-TDRSS contacts.
Tissue-Point Motion Tracking in the Tongue from Cine MRI and Tagged MRI
ERIC Educational Resources Information Center
Woo, Jonghye; Stone, Maureen; Suo, Yuanming; Murano, Emi Z.; Prince, Jerry L.
2014-01-01
Purpose: Accurate tissue motion tracking within the tongue can help professionals diagnose and treat vocal tract--related disorders, evaluate speech quality before and after surgery, and conduct various scientific studies. The authors compared tissue tracking results from 4 widely used deformable registration (DR) methods applied to cine magnetic…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
... information about the request is entered into the appropriate tracking databases. Use of the information in the Agency's tracking databases enables the Agency to monitor progress on the activities attendant to...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benbennick, M.E.; Broton, M.S.; Fuoto, J.S.
This report describes a model tracking system for a low-level radioactive waste (LLW) disposal facility license application. In particular, the model tracks interrogatories (questions, requests for information, comments) and responses. A set of requirements and desired features for the model tracking system was developed, including required structure and computer screens. Nine tracking systems were then reviewed against the model system requirements and only two were found to meet all requirements. Using Kepner-Tregoe decision analysis, a model tracking system was selected.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-27
... Activities; Continued Collection; Comment Request: Vocational Rehabilitation and Employment Tracking Report... on five (5) separate collections of information: (1) VETS 201 entitled ``Vocational Rehabilitation... particularly interested in comments on these topics: (1) Whether the continued collection of information is...
PROTICdb: a web-based application to store, track, query, and compare plant proteome data.
Ferry-Dumazet, Hélène; Houel, Gwenn; Montalent, Pierre; Moreau, Luc; Langella, Olivier; Negroni, Luc; Vincent, Delphine; Lalanne, Céline; de Daruvar, Antoine; Plomion, Christophe; Zivy, Michel; Joets, Johann
2005-05-01
PROTICdb is a web-based application, mainly designed to store and analyze plant proteome data obtained by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and mass spectrometry (MS). The purposes of PROTICdb are (i) to store, track, and query information related to proteomic experiments, i.e., from tissue sampling to protein identification and quantitative measurements, and (ii) to integrate information from the user's own expertise and other sources into a knowledge base, used to support data interpretation (e.g., for the determination of allelic variants or products of post-translational modifications). Data insertion into the relational database of PROTICdb is achieved either by uploading outputs of image analysis and MS identification software, or by filling web forms. 2-D PAGE annotated maps can be displayed, queried, and compared through a graphical interface. Links to external databases are also available. Quantitative data can be easily exported in a tabulated format for statistical analyses. PROTICdb is based on the Oracle or the PostgreSQL Database Management System and is freely available upon request at the following URL: http://moulon.inra.fr/ bioinfo/PROTICdb.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-23
.... 1660-NEW; FEMA Form 089-4, TSGP Investment Justification; FEMA Form 089-27, Fast Track Cost Training...-27, Fast Track Cost Training Matrix. Abstract: The TSGP is an important component of the Department...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-22
... Information Collection: Comment Request OSHC Financial Reporting Form AGENCY: Office of Sustainable Housing... Challenge Planning Grant Program, require the financial reporting by grantees. This tracking of grantee... also lists the following information: Title of Proposal: OSHC Financial Reporting Form. OMB Control...
78 FR 12066 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-21
... OMB Review; Comment Request Title: Tracking of the Early Head Start Research and Evaluation Project (EHSRET) Sample. OMB No.: 0970-0388. Description: The EHSREP is a longitudinal study originally designed.../families who participated in the Early Head Start Research and Evaluation Project (EHSREP) until the...
78 FR 41116 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
... Agreement State regulations. All generators, collectors, and processors of low-level waste intended for... which facilitates tracking the identity of the waste generator. That tracking becomes more complicated... waste shipped from a waste processor may contain waste from several different generators. The...
21 CFR 20.43 - Multitrack processing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PUBLIC... maintained by that component. A multitrack system provides two or more tracks for processing requests, based... single track, ordinarily on a first-in, first-out basis. (c) If a multitrack processing system is...
21 CFR 20.43 - Multitrack processing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PUBLIC... maintained by that component. A multitrack system provides two or more tracks for processing requests, based... single track, ordinarily on a first-in, first-out basis. (c) If a multitrack processing system is...
Automation and quality assurance of the production cycle
NASA Astrophysics Data System (ADS)
Hajdu, L.; Didenko, L.; Lauret, J.
2010-04-01
Processing datasets on the order of tens of terabytes is an onerous task, faced by production coordinators everywhere. Users solicit data productions and, especially for simulation data, the vast amount of parameters (and sometime incomplete requests) point at the need for a tracking, control and archiving all requests made so a coordinated handling could be made by the production team. With the advent of grid computing the parallel processing power has increased but traceability has also become increasing problematic due to the heterogeneous nature of Grids. Any one of a number of components may fail invalidating the job or execution flow in various stages of completion and re-submission of a few of the multitude of jobs (keeping the entire dataset production consistency) a difficult and tedious process. From the definition of the workflow to its execution, there is a strong need for validation, tracking, monitoring and reporting of problems. To ease the process of requesting production workflow, STAR has implemented several components addressing the full workflow consistency. A Web based online submission request module, implemented using Drupal's Content Management System API, enforces ahead that all parameters are described in advance in a uniform fashion. Upon submission, all jobs are independently tracked and (sometime experiment-specific) discrepancies are detected and recorded providing detailed information on where/how/when the job failed. Aggregate information on success and failure are also provided in near real-time.
Siminoff, Laura A; Traino, Heather M; Gordon, Nahida H
2011-10-01
This study explores the effects of tissue requesters' relational, persuasive, and nonverbal communication on families' final donation decisions. One thousand sixteen (N = 1,016) requests for tissue donation were audiotaped and analyzed using the Siminoff Communication Content and Affect Program, a computer application specifically designed to code and assist with the quantitative analysis of communication data. This study supports the important role of communication strategies in health-related decision making. Families were more likely to consent to tissue donation when confirmational messages (e.g., messages that expressed validation or acceptance) or persuasive tactics such as credibility, altruism, or esteem were used during donation discussions. Consent was also more likely when family members exhibited nonverbal immediacy or disclosed private information about themselves or the patient. The results of a hierarchical log-linear regression revealed that the use of relational communication during requests directly predicted family consent. The results provide information about surrogate decision making in end-of-life situations and may be used to guide future practice in obtaining family consent to tissue donation.
77 FR 73453 - Proposed Information Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... ensure that requested data can be provided in the desired format, reporting burden (time and financial... resulting data is used by grantees and the CNCS to track performance, as well as to identify trends and to...: Evaluate whether the proposed collection of information is necessary for the proper performance of the...
75 FR 27346 - Agency Information Collection Request. 30-Day Public Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... of a proposed collection for public comment. Interested persons are invited to send comments... plans, employers, and health care providers. We know very little about why consumers, and specifically... the newer, more robust Internet-based tools for tracking their health and health care services. This...
76 FR 18223 - Proposed Information Collection Activity; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-01
... Information Collection Activity; Comment Request Title: Descriptive Study of Early Head Start (Early Head... tracking for the peri-natal cohort of the Descriptive Study of Early Head Start (Early Head Start Family... Families, Office of Planning, Research and Evaluation, 370 L'Enfant Promenade, SW., Washington, DC 20447...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
... containers, and track the serial numbers to their certificates of conformity. Any information submitted for... Gasoline Containers (Renewal) AGENCY: Environmental Protection Agency (EPA). ACTION: Notice. [[Page 41059...), ``Control of Evaporative Emissions from Portable Gasoline Containers (Renewal) (EPA ICR No. 2213.04, OMB...
Kelliher, Clare; Engler, Christoph; Speck, Caroline; Ward, Don; Farazdaghi, Sameera; Jun, Albert S
2009-10-01
The purpose of this study was to assess eye bank-prepared corneal tissue with regards to the accuracy of postcut tissue thickness, endothelial cell loss, and rate of successful processing. Details of all 913 corneal tissues processed with an automated microkeratome for use in posterior lamellar transplantation, over a 1-year period, were obtained from a large eye bank. The number and success rate of all attempted cutting procedures were analyzed. The thickness of the corneal button obtained after cutting was compared with the graft thickness requested by the operating surgeon. Changes in endothelial cell density (ECD) during tissue processing were evaluated. The rate of successful tissue preparation increased over the time period examined, from 95% in the first quarter to 99.5% in the fourth quarter. Graft material was frequently slightly thicker than requested by the operating surgeon with 28.3% of tissues cut thicker than requested. Postcut ECD over the entire period increased by an average of 4.7% and was closely related to the starting ECD. There was a very high rate of successful tissue preparation (98.5%), and early failed attempts at tissue cutting were likely the result of the initial learning curve of the involved technicians. Practical considerations resulted in tissue being cut marginally thicker than requested; this is an issue about which the operating surgeon should be aware, because it may possibly influence tissue handling. The quality of the obtained material, as measured by ECD, was excellent, although the calculated ECD may be prone to measurement artifact.
75 FR 66379 - Agency Information Collection Activities: Proposed Collection: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-28
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Health Resources and Services Administration Agency... Health Resources and Services Administration's (HRSA) HIV/AIDS Bureau to track spending requirements for... collected. However, the first report would track the allocation of the award at the beginning of the grant...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-20
... is entered into the appropriate tracking databases. Use of the information in the Agency's tracking databases enables the Agency to monitor progress on the activities attendant to scheduling and holding a... collection of information on respondents, including through the use of automated collection techniques, when...
49 CFR 7.32 - Final determinations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... component using multitrack processing may provide persons making appeals in its slower track(s) with an... Transportation Office of the Secretary of Transportation PUBLIC AVAILABILITY OF INFORMATION Time Limits § 7.32... extended by up to ten Federal working days in accordance with § 7.33. The person making the request will be...
76 FR 73770 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-29
.... GWWL requests a waiver for TrackMobile 4650 used for in-plant switching confined to the tracks and..., as well as any written communications concerning the petition, is available for review online at http... communications concerning these proceedings should identify the appropriate docket number and may be submitted by...
75 FR 82032 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-29
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Health Resources and Services Administration Agency... Administration's HIV/AIDS Bureau to track spending requirements for each program as outlined in the legislation... the types of information that are collected. However, the first report would track the allocation of...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-15
... also help improve questionnaire design. Different respondents may pay differing degrees of attention to... and strategies for improving the design (Refs. 5 and 6). Finally, eye tracking data can provide... design elements (e.g., prominence, text vs. graphics) will cause variations in information seeking. To...
21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.
Code of Federal Regulations, 2011 CFR
2011-04-01
... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...
21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.
Code of Federal Regulations, 2012 CFR
2012-04-01
... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...
21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.
Code of Federal Regulations, 2010 CFR
2010-04-01
... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...
21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.
Code of Federal Regulations, 2013 CFR
2013-04-01
... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...
77 FR 37912 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
.... Project: Enhancing Substance Abuse Treatment Services To Address Hepatitis Infection Among Intravenous Drug Users Hepatitis Testing and Vaccine Tracking Form (OMB No. 0930-0300)--Reinstatement and Extension... Treatment (CSAT), is responsible for the Hepatitis Testing and Vaccine Tracking Form for the prevention of...
Code of Federal Regulations, 2010 CFR
2010-04-01
... name, address, telephone number, and social security number (if available) of the patient receiving the...; (ii) The name, address, telephone number, and social security number (if available) of the patient... the manufacturer of the tracked device for audit upon written request by an authorized representative...
Code of Federal Regulations, 2011 CFR
2011-04-01
... name, address, telephone number, and social security number (if available) of the patient receiving the...; (ii) The name, address, telephone number, and social security number (if available) of the patient... the manufacturer of the tracked device for audit upon written request by an authorized representative...
Code of Federal Regulations, 2010 CFR
2010-04-01
... TISSUE-BASED PRODUCTS Current Good Tissue Practice § 1271.290 Tracking. (a) General. If you perform any... designed to facilitate effective tracking, using the distinct identification code, from the donor to the... for recording the distinct identification code and type of each HCT/P distributed to a consignee to...
Automated Computer Access Request System
NASA Technical Reports Server (NTRS)
Snook, Bryan E.
2010-01-01
The Automated Computer Access Request (AutoCAR) system is a Web-based account provisioning application that replaces the time-consuming paper-based computer-access request process at Johnson Space Center (JSC). Auto- CAR combines rules-based and role-based functionality in one application to provide a centralized system that is easily and widely accessible. The system features a work-flow engine that facilitates request routing, a user registration directory containing contact information and user metadata, an access request submission and tracking process, and a system administrator account management component. This provides full, end-to-end disposition approval chain accountability from the moment a request is submitted. By blending both rules-based and rolebased functionality, AutoCAR has the flexibility to route requests based on a user s nationality, JSC affiliation status, and other export-control requirements, while ensuring a user s request is addressed by either a primary or backup approver. All user accounts that are tracked in AutoCAR are recorded and mapped to the native operating system schema on the target platform where user accounts reside. This allows for future extensibility for supporting creation, deletion, and account management directly on the target platforms by way of AutoCAR. The system s directory-based lookup and day-today change analysis of directory information determines personnel moves, deletions, and additions, and automatically notifies a user via e-mail to revalidate his/her account access as a result of such changes. AutoCAR is a Microsoft classic active server page (ASP) application hosted on a Microsoft Internet Information Server (IIS).
77 FR 32433 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-01
... front spar of the wing through the slat track housing. This action revises that NPRM by adding...-on actions. Requests To Clarify Reporting Results Boeing, Delta Air Lines (Delta), and FedEx... request is not shown in paragraph (h) of the NPRM (75 FR 31327, June 3, 2010). Delta stated that reporting...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-13
... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health Submission for OMB Review... Office of Management and Budget (OMB) a request to review and approve the information collection listed... measurement error structure of the diet and physical activity assessment instruments and the heterogeneity of...
32 CFR 1701.7 - Requests for notification of and access to records.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the specific Privacy Act System of Records Notice. To ensure proper routing and tracking, requesters... are not subject to review by subject individuals: (1) Records in ODNI systems of records that ODNI has... existence or nonexistence of responsive records (see § 1701.10(c)(iii)). (2) Records in ODNI systems of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-29
... Request: Extension. Abstract: This information collection is to ensure that Canadian wheat imported into... importers, subsequent buyers, and end-users that assists in tracking the Canadian wheat within the U.S... to average 0.175 hours per response. Respondents: Wheat importers, traders, and end-users. Estimated...
An analysis of particle track effects on solid mammalian tissues
NASA Technical Reports Server (NTRS)
Todd, P.; Clarkson, T. W. (Principal Investigator)
1992-01-01
Relative biological effectiveness (RBE) and quality factor (Q) at extreme values of linear energy transfer (LET) have been determined on the basis of experiments with single-cell systems and specific tissue responses. In typical single-cell systems, each heavy particle (Ar or Fe) passes through a single cell or no cell. In experiments on animal tissues, however, each heavy particle passes through several cells, and the LET can exceed 200 keV micrometers-1 in every cell. In most laboratory animal tissue systems, however, only a small portion of the hit cells are capable of expressing the end-point being measured, such as cell killing, mutation or carcinogenesis. The following question was therefore addressed: do RBEs and Q factors derived from single-cell experiments properly account for the damage at high LET when multiple cells are hit by HZE tracks? A review is offered in which measured radiation effects and known tissue properties are combined to estimate on the one hand, the number of cells at risk, p3n, per track, where n is the number of cells per track based on tissue and organ geometry, and p3 is the probability that a cell in the track is capable of expressing the experimental end-point. On the other hand, the tissue and single-cell responses are compared by determining the ratio RBE in tissue/RBE in corresponding single cells. Experimental data from the literature indicate that tissue RBEs at very high LET (Fe and Ar ions) are higher than corresponding single-cell RBEs, especially in tissues in which p3n is high.
40 CFR 78.3 - Petition for administrative review and request for evidentiary hearing.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Ozone Season NOX Allowance Tracking System account, covered by the decision; or (ii) Any interested... for any CAIR Ozone Season NOX Allowance Tracking System account, covered by the decision; or (ii) Any... concise brief in support of the petition, explaining why the factual or legal issues are material and, if...
Conflict-Aware Scheduling Algorithm
NASA Technical Reports Server (NTRS)
Wang, Yeou-Fang; Borden, Chester
2006-01-01
conflict-aware scheduling algorithm is being developed to help automate the allocation of NASA s Deep Space Network (DSN) antennas and equipment that are used to communicate with interplanetary scientific spacecraft. The current approach for scheduling DSN ground resources seeks to provide an equitable distribution of tracking services among the multiple scientific missions and is very labor intensive. Due to the large (and increasing) number of mission requests for DSN services, combined with technical and geometric constraints, the DSN is highly oversubscribed. To help automate the process, and reduce the DSN and spaceflight project labor effort required for initiating, maintaining, and negotiating schedules, a new scheduling algorithm is being developed. The scheduling algorithm generates a "conflict-aware" schedule, where all requests are scheduled based on a dynamic priority scheme. The conflict-aware scheduling algorithm allocates all requests for DSN tracking services while identifying and maintaining the conflicts to facilitate collaboration and negotiation between spaceflight missions. These contrast with traditional "conflict-free" scheduling algorithms that assign tracks that are not in conflict and mark the remainder as unscheduled. In the case where full schedule automation is desired (based on mission/event priorities, fairness, allocation rules, geometric constraints, and ground system capabilities/ constraints), a conflict-free schedule can easily be created from the conflict-aware schedule by removing lower priority items that are in conflict.
Selka, F; Nicolau, S; Agnus, V; Bessaid, A; Marescaux, J; Soler, L
2015-03-01
In minimally invasive surgery, the tracking of deformable tissue is a critical component for image-guided applications. Deformation of the tissue can be recovered by tracking features using tissue surface information (texture, color,...). Recent work in this field has shown success in acquiring tissue motion. However, the performance evaluation of detection and tracking algorithms on such images are still difficult and are not standardized. This is mainly due to the lack of ground truth data on real data. Moreover, in order to avoid supplementary techniques to remove outliers, no quantitative work has been undertaken to evaluate the benefit of a pre-process based on image filtering, which can improve feature tracking robustness. In this paper, we propose a methodology to validate detection and feature tracking algorithms, using a trick based on forward-backward tracking that provides an artificial ground truth data. We describe a clear and complete methodology to evaluate and compare different detection and tracking algorithms. In addition, we extend our framework to propose a strategy to identify the best combinations from a set of detector, tracker and pre-process algorithms, according to the live intra-operative data. Experimental results have been performed on in vivo datasets and show that pre-process can have a strong influence on tracking performance and that our strategy to find the best combinations is relevant for a reasonable computation cost. Copyright © 2014 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
.... DATES: Comments Due Date: February 8, 2013. ADDRESSES: Interested persons are invited to submit comments... model is needed because participant self-selection into FSS limits the ability to know whether program.... Tracking survey sample 3,000 1 Maximum of 1 hour over 3,000 hours. the tracking period, mainly to update...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-29
... notice. This notice solicits comments on research entitled, ``Eye Tracking Study of Direct-to-Consumer... the FDA to conduct research relating to health information. Section 1003(d)(2)(C) of the Federal Food, Drug, and Cosmetic Act (the FD&C Act) (21 U.S.C. 393(b)(2)(c)) authorizes FDA to conduct research...
Work-family balance and academic advancement in medical schools.
Fox, Geri; Schwartz, Alan; Hart, Katherine M
2006-01-01
This study examines various options that a faculty member might exercise to achieve work-family balance in academic medicine and their consequences for academic advancement. Three data sets were analyzed: an anonymous web-administered survey of part-time tenure track-eligible University of Illinois College of Medicine (UI-COM) faculty members conducted in 2003; exogenous data regarding the entire UI-COM faculty; and tenure rollback ("stop-the-clock") usage by all tenure track-eligible UI-COM faculty from 1994 to 2003. The data reveal a gender split in career-family balance priorities that affect academic advancement among part-time faculty. Women select part-time status for child care; men choose part-time to moonlight. Similarly, among all faculty members seeking tenure rollbacks, women request rollback for child care; men request rollback for other reasons. Among all faculty members, full-time men were more likely to be on the tenure track than any other group. Needs identified by the part-time faculty survey include improved mentoring in track selection, heightened awareness of options, such as tenure rollback, and provision of equitable benefits and opportunities. Policy changes, such as a prorated tenure track, are needed to support a family-friendly culture with flexibility throughout the career lifespan for both men and women medical faculty.
ERIC Educational Resources Information Center
Sandgren, Olof; Andersson, Richard; van de Weijer, Joost; Hansson, Kristina; Sahlen, Birgitta
2012-01-01
Background: This study investigates gaze behaviour in child dialogues. In earlier studies the authors have investigated the use of requests for clarification and responses in order to study the co-creation of understanding in a referential communication task. By adding eye tracking, this line of research is now expanded to include non-verbal…
75 FR 27383 - CSX Transportation, Inc.-Abandonment Exemption-in Marion County, IN.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-14
... Running Track, in Indianapolis, Marion County, Ind. The line traverses United States Postal Service Zip... interim trail use. Any request for a public use condition under 49 CFR 1152.28 or for trail use/rail banking under 49 CFR 1152.29 will be due no later than June 3, 2010. Each trail use request must be...
Cancer Data Access System (CDAS) | Division of Cancer Prevention
The Cancer Data Access System (CDAS) is a submission and tracking system for the use of data from the National Lung Screening Trial (NLST) and the Prostate, Lung, Colorectal and Ovarian (PLCO) Cancer Screening Trial.Interested investigators can register with CDAS and request access to data from either screening trial. All requests are reviewed by NCI trial leadership. Upon
Implementation and evaluation of a web based system for pharmacy stock management in rural Haiti.
Berger, Elisabeth J; Jazayeri, Darius; Sauveur, Marcel; Manasse, Jean Joel; Plancher, Inel; Fiefe, Marquise; Laurat, Guerline; Joseph, Samahel; Kempton, Kathryn; Fraser, Hamish S F
2007-10-11
Managing the stock and supply of medication is essential for the provision of health care, especially in resource poor areas of the world. We have developed an innovative, web-based stock management system to support nine clinics in rural Haiti. Building on our experience with a web-based EMR system for our HIV patients, we developed a comprehensive stock tracking system that is modeled on the appearance of standardized WHO stock cards. The system allows pharmacy staff at all clinics to enter stock levels and also to request drugs and track shipments. Use of the system over the last 2 years has increased rapidly and we now track 450 products supporting care for 1.78 million patient visits annually. Over the last year drug stockouts have fallen from 2.6% to 1.1% and 97% of stock requests delivered were shipped within 1 day. We are now setting up this system in our clinics in rural Rwanda.
Mercado, Karla P; Langdon, Jonathan; Helguera, María; McAleavey, Stephen A; Hocking, Denise C; Dalecki, Diane
2015-08-01
The physical environment of engineered tissues can influence cellular functions that are important for tissue regeneration. Thus, there is a critical need for noninvasive technologies capable of monitoring mechanical properties of engineered tissues during fabrication and development. This work investigates the feasibility of using single tracking location shear wave elasticity imaging (STL-SWEI) for quantifying the shear moduli of tissue-mimicking phantoms and engineered tissues in tissue engineering environments. Scholte surface waves were observed when STL-SWEI was performed through a fluid standoff, and confounded shear moduli estimates leading to an underestimation of moduli in regions near the fluid-tissue interface.
SIMINOFF, LAURA A.; TRAINO, HEATHER M.; GORDON, NAHIDA H.
2011-01-01
This study explores the effects of tissue requesters’ relational, persuasive, and nonverbal communication on families’ final donation decisions. One thousand sixteen (N=1,016) requests for tissue donation were audiotaped and analyzed using the Siminoff Communication Content and Affect Program, a computer application specifically designed to code and assist with the quantitative analysis of communication data. This study supports the important role of communication strategies in health-related decision making. Families were more likely to consent to tissue donation when confirmational messages (e.g., messages that expressed validation or acceptance) or persuasive tactics such as credibility, altruism, or esteem were used during donation discussions. Consent was also more likely when family members exhibited nonverbal immediacy or disclosed private information about themselves or the patient. The results of a hierarchical log-linear regression revealed that the use of relational communication during requests directly predicted family consent. The results provide information about surrogate decision making in end-of-life situations and may be used to guide future practice in obtaining family consent to tissue donation. PMID:21512935
Cell Membrane Tracking in Living Brain Tissue Using Differential Interference Contrast Microscopy.
Lee, John; Kolb, Ilya; Forest, Craig R; Rozell, Christopher J
2018-04-01
Differential interference contrast (DIC) microscopy is widely used for observing unstained biological samples that are otherwise optically transparent. Combining this optical technique with machine vision could enable the automation of many life science experiments; however, identifying relevant features under DIC is challenging. In particular, precise tracking of cell boundaries in a thick ( ) slice of tissue has not previously been accomplished. We present a novel deconvolution algorithm that achieves the state-of-the-art performance at identifying and tracking these membrane locations. Our proposed algorithm is formulated as a regularized least squares optimization that incorporates a filtering mechanism to handle organic tissue interference and a robust edge-sparsity regularizer that integrates dynamic edge tracking capabilities. As a secondary contribution, this paper also describes new community infrastructure in the form of a MATLAB toolbox for accurately simulating DIC microscopy images of in vitro brain slices. Building on existing DIC optics modeling, our simulation framework additionally contributes an accurate representation of interference from organic tissue, neuronal cell-shapes, and tissue motion due to the action of the pipette. This simulator allows us to better understand the image statistics (to improve algorithms), as well as quantitatively test cell segmentation and tracking algorithms in scenarios, where ground truth data is fully known.
2016-03-01
At the request of the authors, the following article has been retracted by the Editor and publishers of Psychological Science:Fisher, C. I., Hahn, A. C., DeBruine, L. M., & Jones, B. C. (2015). Women's preference for attractive makeup tracks changes in their salivary testosterone. Psychological Science, 26, 1958-1964. doi:10.1177/0956797615609900. © The Author(s) 2016.
77 FR 72335 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-05
... computer networks, systems, or databases. The records contain the individual's name; social security number... control and track access to DLA-controlled networks, computer systems, and databases. The records may also...
76 FR 34138 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
... safety manual; a clear delineation of employers' responsibilities, as well as employees' rights and responsibilities thereto; well-defined procedures for communication and protection; and annual on-track safety...
Menor Almagro, Raúl; Rodríguez Gutiérrez, Juan Francisco; Martín-Martínez, María Auxiliadora; Rodríguez Valls, María José; Aranda Valera, Concepción; de la Iglesia Salgado, José Luís
To determine the dilution titles at antinuclear antibodies (ANA) by indirect immunofluorescence observed in cell substrate HEp-2 and its association with the diagnosis of systemic connective tissue disease in ANA test requested by a Rheumatology Unit. Samples of patients attended for the first time in the rheumatology unit, without prior ANA test, between January 2010 and December 2012 were selected. The dilution titers, immunofluorescence patterns and antigen specificity were recorded. In January 2015 the diagnosis of the patients were evaluated and classified in systemic disease connective tissue (systemic lupus erythematosus, Sjögren's syndrome, systemic sclerosis, undifferentiated connective, antiphospholipid syndrome, mixed connective tissue and inflammatory myophaty) or not systemic disease connective tissue. A total of 1282 ANA tests requested by the Rheumatology Unit in subjects without previous study, 293 were positive, predominance of women (81.9%). Patients with systemic connective tissue disease were recorded 105, and 188 without systemic connective tissue disease. For 1/640 dilutions the positive predictive value in the connective was 73.3% compared to 26.6% of non-connective, and for values ≥1/1,280 85% versus 15% respectively. When performing the multivariate analysis we observed a positive association between 1/320 dilution OR 3.069 (95% CI: 1.237-7.614; P=.016), 1/640 OR 12.570 (95% CI: 3.659-43.187; P=.000) and ≥1/1,280 OR 42.136 (95% CI: 8.604-206.345; P=.000). These results show association titles dilution ≥1/320 in ANA's first test requested by a Rheumatology Unit with patients with systemic connective tissue disease. The VPP in these patients was higher than previous studies requested by other medical specialties. This may indicate the importance of application of the test in a targeted way. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-01
... establishments of which 145 are conventional tissue banks and 112 are eye tissue banks. Based on information...,115 donors of eye tissue each year. Accredited members of the American Association of Tissue Banks... system, 90 percent of the conventional tissue banks are members of AATB (145 x 90% = 130), and 77 percent...
NASA Astrophysics Data System (ADS)
Ilina, Olga; Bakker, Gert-Jan; Vasaturo, Angela; Hoffman, Robert M.; Friedl, Peter
2011-02-01
Cancer invasion into an extracellular matrix (ECM) results from a biophysical reciprocal interplay between the expanding cancer lesion and tissue barriers imposed by the adjacent microenvironment. In vivo, connective tissue provides both densely packed ECM barriers adjacent to channel/track-like spaces and loosely organized zones, both of which may impact cancer invasion mode and efficiency; however little is known about how three-dimensional (3D) spaces and aligned tracks present in interstitial tissue guide cell invasion. We here describe a two-photon laser ablation procedure to generate 3D microtracks in dense 3D collagen matrices that support and guide collective cancer cell invasion. Whereas collective invasion of mammary tumor (MMT) breast cancer cells into randomly organized collagen networks required matrix metalloproteinase (MMP) activity for cell-derived collagen breakdown, re-alignment and track generation, preformed tracks supported MMP-independent collective invasion down to a track caliber of 3 µm. Besides contact guidance along the track of least resistance and initial cell deformation (squeezing), MMP-independent collective cell strands led to secondary track expansion by a pushing mechanism. Thus, two-photon laser ablation is useful to generate barrier-free microtracks in a 3D ECM which guide collective invasion independently of pericellular proteolysis.
Pre-installation customer satisfaction survey
DOT National Transportation Integrated Search
1996-10-01
The National Center for Statistics and Analysis (NCSA) Information Services Branch (ISB) required a more effective method of receiving, tracking, and completing requests for data, statistics, and information. To enhance ISBs services, a new cus...
NASA Astrophysics Data System (ADS)
Dhutia, Niti M.; Zolgharni, Massoud; Willson, Keith; Cole, Graham; Nowbar, Alexandra N.; Manisty, Charlotte H.; Francis, Darrel P.
2014-03-01
Some of the challenges with tissue Doppler measurement include: apparent inconsistency between manufacturers, uncertainty over which part of the trace to make measurements and a lack of calibration of measurements. We develop and test tools to solve these problems in echocardiography laboratories. We designed and constructed an actuator and phantom setup to produce automatic reproducible motion, and used it to compare velocities measured using 3 echocardiographic modalities: M-mode, speckle tracking, and tissue Doppler, against a non-ultrasound, optical gold standard. In the clinical phase, 25 patients underwent M-mode, speckle tracking and tissue Doppler measurements of tissue velocities. In-vitro, the M-mode and speckle tracking velocities were concordant with optical assessment. Of the three possible tissue Doppler measurement conventions (outer, middle and inner line) only the middle line agreed with the optical assessment (discrepancy -0.20 (95% confidence interval -0.44 to 0.03)cm/s, p=0.11, outer +5.19(4.65 to 5.73)cm/s, p<0.0001, inner -6.26(-6.87 to -5.65)cm/s, p<0.0001). All 4 studied manufacturers showed a similar pattern. M-mode was therefore chosen as the in-vivo gold standard. Clinical measurements of tissue velocities by speckle tracking and the middle line of the tissue Doppler were concordant with M-mode, while the outer line significantly overestimated (+1.27(0.96 to 1.59)cm/s, p<0.0001) and the inner line underestimated (-1.81(-2.11 to -1.52)cm/s, p<0.0001). Echocardiographic velocity measurements can be calibrated by simple, inexpensive tools. We found that the middle of the tissue Doppler trace represents velocity correctly. Echocardiographers requiring velocities to match between different equipment, settings or modalities should use the middle line as the "guideline".
Nutrition in Children with Chronic Kidney Disease
... How can understanding and keeping track of lab reports help a child with CKD make healthy food ... Caretakers can request copies of their child’s lab reports and ask to have them explained, noting any ...
Results of interlaboratory comparison of fission track ages for 1992 fission track workshop
Miller, D.S.; Crowley, K.D.; Dokka, R.K.; Galbraith, R.F.; Kowallis, B.J.; Naeser, C.W.
1993-01-01
Two apatites and one sphene were made available to the fission track research community for analysis prior to the 1992 Fission Track Workshop held in Philadelphia, U.S.A., 13-17 July. Eighteen laboratories throughout the world received aliquots of apatite and sphene. To date, analyses by 33 different scientists have been representing 15 different laboratories. With respect to the previous two interlaboratory comparisons, there is a noticeable improvement in the accuracy of the age results (Naeser and Cebula, 1978; Naeser et al., 1981; Miller et al., 1985;Miller et al.1990). Ninety-four percent of the analysis used the external detector method (EDM) combined with the zeta technique while the remaining individuals used the population method (POP). Track length measurements (requested for the first time in the interlaboratory comparison studies) were in relatively good agreement. ?? 1993.
77 FR 61004 - Request for Nominations for Voting Members on Public Advisory Committees
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-05
...--individuals knowledgeable in tissue engineering/regenerative medicine, orthopedic oncology. [[Page 61005... Committee, Cellular, Tissue and Gene Therapies Advisory Committee, and Transmissible Spongiform and... . Advisory Committee. Gail Dapolito, Center for Biologics Cellular, Tissue and Gene Evaluation and Research...
Uhlmann, Wendy R; Schwalm, Katie; Raymond, Victoria M
2017-08-01
Obtaining genetic testing insurance authorizations for patients is a complex, time-involved process often requiring genetic counselor (GC) and physician involvement. In an effort to mitigate this complexity and meet the increasing number of genetic testing insurance authorization requests, GCs formed a novel partnership with an industrial engineer (IE) and a patient services associate (PSA) to develop a streamlined work flow. Eight genetics clinics and five specialty clinics at the University of Michigan were surveyed to obtain benchmarking data. Tasks needed for genetic testing insurance authorization were outlined and time-saving work flow changes were introduced including 1) creation of an Excel password-protected shared database between GCs and PSAs, used for initiating insurance authorization requests, tracking and follow-up 2) instituting the PSAs sending GCs a pre-clinic email noting each patients' genetic testing insurance coverage 3) inclusion of test medical necessity documentation in the clinic visit summary note instead of writing a separate insurance letter and 4) PSAs development of a manual with insurance providers and genetic testing laboratories information. These work flow changes made it more efficient to request and track genetic testing insurance authorizations for patients, enhanced GCs and PSAs communication, and reduced tasks done by clinicians.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-20
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-894] Certain Tissue Paper... on certain tissue paper products from the People's Republic of China (PRC) for the period of review... of opportunity to request an administrative review of the antidumping duty order on certain tissue...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-14
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-894] Certain Tissue Paper... antidumping duty order on certain tissue paper products from the People's Republic of China (PRC) for the... opportunity to request an administrative review of the antidumping duty order on certain tissue paper products...
Overview of the TREC 2009 Legal Track
2009-11-01
on the IIT CDIP 1.0 collection [9]), we turned, in 2009, to a collection of emails that had been produced by Enron in response to requests from the...collection as the 2006–2008 Legal Tracks, the IIT Complex Document Information Processing ( CDIP ) Test Collection, version 1.0 (referred to here as “IIT... CDIP 1.0”) which is based on scanned documents released under the tobacco “Master Settlement Agreement” (MSA). The University of California San
76 FR 66683 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-27
...: National Oceanic and Atmospheric Administration (NOAA). Title: Protocol for Access to Tissue Specimen Samples from the National Marine Mammal Tissue Bank. OMB Control Number: 0648-0468. Form Number(s): NA..., the National Marine Mammal Tissue Bank (NMMTB) was established by the National Marine Fisheries...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... (NI) grantees. The agency has used the application, semi-annual reports and close-out reports to track... Neighborhood Initiative (NI) grantees. The agency has used the application, semi-annual reports and close-out...
Code of Federal Regulations, 2013 CFR
2013-01-01
... available for the purchase of a new hurricane tracking device. The budget officer does not have official... an issue concerning a request from a news organization for information concerning past agency...
Code of Federal Regulations, 2014 CFR
2014-01-01
... available for the purchase of a new hurricane tracking device. The budget officer does not have official... an issue concerning a request from a news organization for information concerning past agency...
Code of Federal Regulations, 2012 CFR
2012-01-01
... available for the purchase of a new hurricane tracking device. The budget officer does not have official... an issue concerning a request from a news organization for information concerning past agency...
DOT National Transportation Integrated Search
2010-02-01
Washington State Department of Transportation Local Programs Division requested the creation of a : Resource Planning Index (or Index) for use in benchmarking and tracking the stewardship : performance of investments associated with Washington...
Faculty career tracks at U.S. medical schools.
Coleman, Michelle M; Richard, George V
2011-08-01
To describe faculty career tracks at U.S. MD-granting schools and explore which institutional characteristics are associated with the career tracks. Between 2008 and 2009, the authors sought the faculty policies of 129 accredited MD-granting U.S. medical schools, through online searching and requests to faculty affairs representatives. An inventory of tenured and nontenured career tracks was conducted in the areas of teaching, research, and clinical care. Career track data were analyzed according to institutional characteristics. Complete data were collected from 98 schools (76%). On average, schools offered 3.6 career tracks to all faculty (range 1-8). Of the 353 career tracks identified, 210 were nontenured. Overall, schools offered more research tracks than education or clinical tracks. Of the 79 schools with clearly defined career tracks, 78 offered at least one clinical track; 34 offered at least one education track. Approximately 25% of the clinical tracks were tenured; 41% of the education tracks were tenured. Of the 98 schools, 61% used modified titles for faculty pursuing nontenure tracks. Schools that offered more career tracks were more likely to use modified titles for their nontenured clinical and research faculty. Schools with a smaller faculty size offered a greater number of clinical tracks, whereas community-based schools offered fewer clinical tracks. Research-intensive schools provided significantly more tenured clinical tracks. There is great variation in faculty tracks and policies across institutions. This research may help institutions craft their own faculty policies and help students, residents, and faculty in making career decisions.
Estimating soft tissue thickness from light-tissue interactions––a simulation study
Wissel, Tobias; Bruder, Ralf; Schweikard, Achim; Ernst, Floris
2013-01-01
Immobilization and marker-based motion tracking in radiation therapy often cause decreased patient comfort. However, the more comfortable alternative of optical surface tracking is highly inaccurate due to missing point-to-point correspondences between subsequent point clouds as well as elastic deformation of soft tissue. In this study, we present a proof of concept for measuring subcutaneous features with a laser scanner setup focusing on the skin thickness as additional input for high accuracy optical surface tracking. Using Monte-Carlo simulations for multi-layered tissue, we show that informative features can be extracted from the simulated tissue reflection by integrating intensities within concentric ROIs around the laser spot center. Training a regression model with a simulated data set identifies patterns that allow for predicting skin thickness with a root mean square error of down to 18 µm. Different approaches to compensate for varying observation angles were shown to yield errors still below 90 µm. Finally, this initial study provides a very promising proof of concept and encourages research towards a practical prototype. PMID:23847741
An AI Approach to Ground Station Autonomy for Deep Space Communications
NASA Technical Reports Server (NTRS)
Fisher, Forest; Estlin, Tara; Mutz, Darren; Paal, Leslie; Law, Emily; Stockett, Mike; Golshan, Nasser; Chien, Steve
1998-01-01
This paper describes an architecture for an autonomous deep space tracking station (DS-T). The architecture targets fully automated routine operations encompassing scheduling and resource allocation, antenna and receiver predict generation. track procedure generation from service requests, and closed loop control and error recovery for the station subsystems. This architecture has been validated by the construction of a prototype DS-T station, which has performed a series of demonstrations of autonomous ground station control for downlink services with NASA's Mars Global Surveyor (MGS).
Cancer cell motility: lessons from migration in confined spaces
Paul, Colin D.; Mistriotis, Panagiotis; Konstantopoulos, Konstantinos
2017-01-01
Time-lapse, deep-tissue imaging made possible by advances in intravital microscopy has demonstrated the importance of tumour cell migration through confining tracks in vivo. These tracks may either be endogenous features of tissues or be created by tumour or tumour-associated cells. Importantly, migration mechanisms through confining microenvironments are not predicted by 2D migration assays. Engineered in vitro models have been used to delineate the mechanisms of cell motility through confining spaces encountered in vivo. Understanding cancer cell locomotion through physiologically relevant confining tracks could be useful in developing therapeutic strategies to combat metastasis. PMID:27909339
Software Assists in Extensive Environmental Auditing
NASA Technical Reports Server (NTRS)
Callac, Christopher; Matherne, Charlie
2002-01-01
The Base Enivronmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists on an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign manditory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: It helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.
Software Assists in Extensive Environmental Auditing
NASA Technical Reports Server (NTRS)
Callac, Christopher; Matherne, Charlie
2003-01-01
The Base Environmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists of an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign mandatory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: it helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.
Software Assists in Extensive Environmental Auditing
NASA Technical Reports Server (NTRS)
Callac, Christopher; Matherne, Charlie; Selinsky, T.
2002-01-01
The Base Environmental Management System (BEMS) is a Web-based application program for managing and tracking audits by the Environmental Office of Stennis Space Center in conformity with standard 14001 of the International Organization for Standardization (ISO 14001). (This standard specifies requirements for an environmental-management system.) BEMS saves time by partly automating what were previously manual processes for creating audit checklists; recording and tracking audit results; issuing, tracking, and implementing corrective-action requests (CARs); tracking continuous improvements (CIs); and tracking audit results and statistics. BEMS consists of an administration module and an auditor module. As its name suggests, the administration module is used to administer the audit. It helps administrators to edit the list of audit questions; edit the list of audit locations; assign mandatory questions to locations; track, approve, and edit CARs; and edit completed audits. The auditor module is used by auditors to perform audits and record audit results: it helps the auditors to create audit checklists, complete audits, view completed audits, create CARs, record and acknowledge CIs, and generate reports from audit results.
NASA Astrophysics Data System (ADS)
Adams, Matthew; Salgaonkar, Vasant; Jones, Peter; Plata, Juan; Chen, Henry; Pauly, Kim Butts; Sommer, Graham; Diederich, Chris
2017-03-01
An MR-guided endoluminal ultrasound applicator has been proposed for palliative and potential curative thermal therapy of pancreatic tumors. Minimally invasive ablation or hyperthermia treatment of pancreatic tumor tissue would be performed with the applicator positioned in the gastrointestinal (GI) lumen, and sparing of the luminal tissue would be achieved with a water-cooled balloon surrounding the ultrasound transducers. This approach offers the capability of conformal volumetric therapy for fast treatment times, with control over the 3D spatial deposition of energy. Prototype endoluminal ultrasound applicators have been fabricated using 3D printed fixtures that seat two 3.2 or 5.6 MHz planar or curvilinear transducers and contain channels for wiring and water flow. Spiral surface coils have been integrated onto the applicator body to allow for device localization and tracking for therapies performed under MR guidance. Heating experiments with a tissue-mimicking phantom in a 3T MR scanner were performed and demonstrated capability of the prototype to perform volumetric heating through duodenal luminal tissue under real-time PRF-based MR temperature imaging (MRTI). Additional experiments were performed in ex vivo pig carcasses with the applicator inserted into the esophagus and aimed towards liver or soft tissue surrounding the spine under MR guidance. These experiments verified the capacity of heating targets up to 20-25 mm from the GI tract. Active device tracking and automated prescription of imaging and temperature monitoring planes through the applicator were made possible by using Hadamard encoded tracking sequences to obtain the coordinates of the applicator tracking coils. The prototype applicators have been integrated with an MR software suite that performs real-time device tracking and temperature monitoring.
Murphy, Sean V.; Hale, Austin; Reid, Tanya; Olson, John; Kidiyoor, Amritha; Tan, Josh; Zhou, Zhiguo; Jackson, John; Atala, Anthony
2016-01-01
Magnetic Resonance Imaging (MRI) is a commonly used, non-invasive imaging technique that provides visualization of soft tissues with high spatial resolution. In both a research and clinical setting, the major challenge has been identifying a non-invasive and safe method for longitudinal tracking of delivered cells in vivo. The labeling and tracking of contrast agent labeled cells using MRI has the potential to fulfill this need. Contrast agents are often used to enhance the image contrast between the tissue of interest and surrounding tissues with MRI. The most commonly used MRI contrast agents contain Gd(III) ions. However, Gd(III) ions are highly toxic in their ionic form, as they tend to accumulate in the liver, spleen, kidney and bones and block calcium channels. Endohedral metallofullerenes such as trimetallic nitride endohedral metallofullerenes (Trimetasphere®) are one unique class of fullerene molecules where a Gd3N cluster is encapsulated inside a C80 carbon cage referred to as Gd3N@C80. These endohedral metallofullerenes have several advantages over small chelated Gd(III) complexes such as increased stability of the Gd(III) ion, minimal toxic effects, high solubility in water and high proton relativity. In this study, we describe the evaluation of gadolinium-based Trimetasphere® positive contrast agent for the in vitro labeling and in vivo tracking of human amniotic fluid-derived stem cells within lung tissue. In addition, we conducted a ‘proof-of-concept’ experiment demonstrating that this methodology can be used to track the homing of stem cells to injured lung tissue and provide longitudinal analysis of cell localization over an extended time course. PMID:26546729
Murphy, Sean V; Hale, Austin; Reid, Tanya; Olson, John; Kidiyoor, Amritha; Tan, Josh; Zhou, Zhiguo; Jackson, John; Atala, Anthony
2016-04-15
Magnetic Resonance Imaging (MRI) is a commonly used, non-invasive imaging technique that provides visualization of soft tissues with high spatial resolution. In both a research and clinical setting, the major challenge has been identifying a non-invasive and safe method for longitudinal tracking of delivered cells in vivo. The labeling and tracking of contrast agent labeled cells using MRI has the potential to fulfill this need. Contrast agents are often used to enhance the image contrast between the tissue of interest and surrounding tissues with MRI. The most commonly used MRI contrast agents contain Gd(III) ions. However, Gd(III) ions are highly toxic in their ionic form, as they tend to accumulate in the liver, spleen, kidney and bones and block calcium channels. Endohedral metallofullerenes such as trimetallic nitride endohedral metallofullerenes (Trimetasphere®) are one unique class of fullerene molecules where a Gd3N cluster is encapsulated inside a C80 carbon cage referred to as Gd3N@C80. These endohedral metallofullerenes have several advantages over small chelated Gd(III) complexes such as increased stability of the Gd(III) ion, minimal toxic effects, high solubility in water and high proton relativity. In this study, we describe the evaluation of gadolinium-based Trimetasphere® positive contrast agent for the in vitro labeling and in vivo tracking of human amniotic fluid-derived stem cells within lung tissue. In addition, we conducted a 'proof-of-concept' experiment demonstrating that this methodology can be used to track the homing of stem cells to injured lung tissue and provide longitudinal analysis of cell localization over an extended time course. Copyright © 2015 Elsevier Inc. All rights reserved.
The Establishment of a Formal Midwest Renewable Energy Tracking System (M-RETS) Organization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maria Redmond; Chela Bordas O'Connor
2010-06-30
The objectives identified in requesting and utilizing this funding has been met. The goal was to establish a formal, multi-jurisdictional organization to: (1) ensure the policy objectives of the participating jurisdictions are addressed through increased tradability of the Renewable Energy Credits (RECs) from M-RETS and to eliminate the possibility that a single jurisdiction will be the sole arbiter of the operation of the system; (2) facilitate the establishment of REC standards including the attributes related to, the creation, trading, and interaction with other trading and tracking systems; and (3) have a centralized and established organization that will be responsible formore » the contracting and governance responsibilities of a multi-jurisdictional tracking system. The M-RETS Inc. Board ensures that the system remains policy neutral; that the attributes of generation are tracked in a way that allows the system users to easily identify and trade relevant RECs; that the system can add jurisdictions as needed or desired; and that the tracking system operate in such a way to allow for the greatest access possible for those participating in other tracking or trading systems by allowing those systems to negotiate with a single M-RETS entity for the import and export of RECs. M-RETS as an organizational body participates and often leads the discussions related to the standardization of RECs and increasing the tradability of M-RETS RECs. M-RETS is a founding member of the Environmental Trading Network of North America (ETNNA) and continues to take a leadership role in the development of processes to facilitate trading among tracking systems and to standardize REC definitions. The Board of Directors of M-RETS, Inc., the non-profit corporation, continues to hold telephone/internet Board meetings. Legal counsel continues working with the board and APX management on a new agreement with APX. The board expects to have an agreement and corresponding fee structure in place by January 2011. The Board has recently approved exports to three other tracking systems and is in discussions about imports to the system. Below are the tasks outlined in the request and attached you will find the relevant documentation.« less
75 FR 11864 - Proposed Information Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-12
... Corporation is soliciting comments concerning its proposed renewal of its Senior Corps Project Progress Report... (e.g., permitting electronic submissions of responses). Background The Progress Report (PPR) was... grant requirements; track and measure progress to benefit the local project and its contributions to...
Safety belt and motorcycle helmet use in Virginia : the Summer 2008 update.
DOT National Transportation Integrated Search
2008-01-01
This survey was conducted at the request of the Virginia Department of Motor Vehicles to track the effectiveness of programmatic efforts carried out to increase safety belt usage in Virginia. The official Virginia safety belt use survey is conducted ...
Gaze-contingent control for minimally invasive robotic surgery.
Mylonas, George P; Darzi, Ara; Yang, Guang Zhong
2006-09-01
Recovering tissue depth and deformation during robotically assisted minimally invasive procedures is an important step towards motion compensation, stabilization and co-registration with preoperative data. This work demonstrates that eye gaze derived from binocular eye tracking can be effectively used to recover 3D motion and deformation of the soft tissue. A binocular eye-tracking device was integrated into the stereoscopic surgical console. After calibration, the 3D fixation point of the participating subjects could be accurately resolved in real time. A CT-scanned phantom heart model was used to demonstrate the accuracy of gaze-contingent depth extraction and motion stabilization of the soft tissue. The dynamic response of the oculomotor system was assessed with the proposed framework by using autoregressive modeling techniques. In vivo data were also used to perform gaze-contingent decoupling of cardiac and respiratory motion. Depth reconstruction, deformation tracking, and motion stabilization of the soft tissue were possible with binocular eye tracking. The dynamic response of the oculomotor system was able to cope with frequencies likely to occur under most routine minimally invasive surgical operations. The proposed framework presents a novel approach towards the tight integration of a human and a surgical robot where interaction in response to sensing is required to be under the control of the operating surgeon.
Debate: Should Abortion Be Available on Request?
ERIC Educational Resources Information Center
Nathanson, Bernard; Lawrence, George
1971-01-01
Two physicians debate whether abortions should be available on request regardless of medical indications. The crux of the issue is whether the fetus should be considered body tissue over which the woman has complete control or whether society has an interest in the embryo and should protect it. (Author/BY)
A novel method for quantification of beam's-eye-view tumor tracking performance.
Hu, Yue-Houng; Myronakis, Marios; Rottmann, Joerg; Wang, Adam; Morf, Daniel; Shedlock, Daniel; Baturin, Paul; Star-Lack, Josh; Berbeco, Ross
2017-11-01
In-treatment imaging using an electronic portal imaging device (EPID) can be used to confirm patient and tumor positioning. Real-time tumor tracking performance using current digital megavolt (MV) imagers is hindered by poor image quality. Novel EPID designs may help to improve quantum noise response, while also preserving the high spatial resolution of the current clinical detector. Recently investigated EPID design improvements include but are not limited to multi-layer imager (MLI) architecture, thick crystalline and amorphous scintillators, and phosphor pixilation and focusing. The goal of the present study was to provide a method of quantitating improvement in tracking performance as well as to reveal the physical underpinnings of detector design that impact tracking quality. The study employs a generalizable ideal observer methodology for the quantification of tumor tracking performance. The analysis is applied to study both the effect of increasing scintillator thickness on a standard, single-layer imager (SLI) design as well as the effect of MLI architecture on tracking performance. The present study uses the ideal observer signal-to-noise ratio (d') as a surrogate for tracking performance. We employ functions which model clinically relevant tasks and generalized frequency-domain imaging metrics to connect image quality with tumor tracking. A detection task for relevant Cartesian shapes (i.e., spheres and cylinders) was used to quantitate trackability of cases employing fiducial markers. Automated lung tumor tracking algorithms often leverage the differences in benign and malignant lung tissue textures. These types of algorithms (e.g., soft-tissue localization - STiL) were simulated by designing a discrimination task, which quantifies the differentiation of tissue textures, measured experimentally and fit as a power-law in trend (with exponent β) using a cohort of MV images of patient lungs. The modeled MTF and NPS were used to investigate the effect of scintillator thickness and MLI architecture on tumor tracking performance. Quantification of MV images of lung tissue as an inverse power-law with respect to frequency yields exponent values of β = 3.11 and 3.29 for benign and malignant tissues, respectively. Tracking performance with and without fiducials was found to be generally limited by quantum noise, a factor dominated by quantum detective efficiency (QDE). For generic SLI construction, increasing the scintillator thickness (gadolinium oxysulfide - GOS) from a standard 290 μm to 1720 μm reduces noise to about 10%. However, 81% of this reduction is appreciated between 290 and 1000 μm. In comparing MLI and SLI detectors of equivalent individual GOS layer thickness, the improvement in noise is equal to the number of layers in the detector (i.e., 4) with almost no difference in MTF. Further, improvement in tracking performance was slightly less than the square-root of the reduction in noise, approximately 84-90%. In comparing an MLI detector with an SLI with a GOS scintillator of equivalent total thickness, improvement in object detectability is approximately 34-39%. We have presented a novel method for quantification of tumor tracking quality and have applied this model to evaluate the performance of SLI and MLI EPID designs. We showed that improved tracking quality is primarily limited by improvements in NPS. When compared to very thick scintillator SLI, employing MLI architecture exhibits the same gains in QDE, but by mitigating the effect of optical Swank noise, results in more dramatic improvements in tracking performance. © 2017 American Association of Physicists in Medicine.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... has stated on the records of past segments of the PRC tissue paper proceeding that it is affiliated... DEPARTMENT OF COMMERCE International Trade Administration [A-570-894] Certain Tissue Paper... to a request from Seaman Paper Company of Massachusetts, Inc. (the petitioner), the Department of...
Dedicated ultrasound speckle tracking to study tendon displacement
NASA Astrophysics Data System (ADS)
Korstanje, Jan-Wiebe H.; Selles, Ruud W.; Stam, Henk J.; Hovius, Steven E. R.; Bosch, Johan G.
2009-02-01
Ultrasound can be used to study tendon and muscle movement. However, quantization is mostly based on manual tracking of anatomical landmarks such as the musculotendinous junction, limiting the applicability to a small number of muscle-tendon units. The aim of this study is to quantify tendon displacement without employing anatomical landmarks, using dedicated speckle tracking in long B-mode image sequences. We devised a dedicated two-dimensional multikernel block-matching scheme with subpixel accuracy to handle large displacements over long sequences. Images were acquired with a Philips iE33 with a 7 MHz linear array and a VisualSonics Vevo 770 using a 40 MHz mechanical probe. We displaced the flexor digitorum superficialis of two pig cadaver forelegs with three different velocities (4,10 and 16 mm/s) over 3 distances (5, 10, 15 mm). As a reference, we manually determined the total displacement of an injected hyperechogenic bullet in the tendons. We automatically tracked tendon parts with and without markers and compared results to the true displacement. Using the iE33, mean tissue displacement underestimations for the three different velocities were 2.5 +/- 1.0%, 1.7 +/- 1.1% and 0.7 +/- 0.4%. Using the Vevo770, mean tissue displacement underestimations were 0.8 +/- 1.3%, 0.6 +/- 0.3% and 0.6 +/- 0.3%. Marker tracking displacement underestimations were only slightly smaller, showing limited tracking drift for non-marker tendon tissue as well as for markers. This study showed that our dedicated speckle tracking can quantify extensive tendon displacement with physiological velocities without anatomical landmarks with good accuracy for different types of ultrasound configurations. This technique allows tracking of a much larger range of muscle-tendon units than by using anatomical landmarks.
Localized strain measurements of the intervertebral disc annulus during biaxial tensile testing.
Karakolis, Thomas; Callaghan, Jack P
2015-01-01
Both inter-lamellar and intra-lamellar failures of the annulus have been described as potential modes of disc herniation. Attempts to characterize initial lamellar failure of the annulus have involved tensile testing of small tissue samples. The purpose of this study was to evaluate a method of measuring local surface strains through image analysis of a tensile test conducted on an isolated sample of annular tissue in order to enhance future studies of intervertebral disc failure. An annulus tissue sample was biaxial strained to 10%. High-resolution images captured the tissue surface throughout testing. Three test conditions were evaluated: submerged, non-submerged and marker. Surface strains were calculated for the two non-marker conditions based on motion of virtual tracking points. Tracking algorithm parameters (grid resolution and template size) were varied to determine the effect on estimated strains. Accuracy of point tracking was assessed through a comparison of the non-marker conditions to a condition involving markers placed on tissue surface. Grid resolution had a larger effect on local strain than template size. Average local strain error ranged from 3% to 9.25% and 0.1% to 2.0%, for the non-submerged and submerged conditions, respectively. Local strain estimation has a relatively high potential for error. Submerging the tissue provided superior strain estimates.
Ito, Takahiro; Anzai, Daisuke; Jianqing Wang
2014-01-01
This paper proposes a novel joint time of arrival (TOA)/received signal strength indicator (RSSI)-based wireless capsule endoscope (WCE) location tracking method without prior knowledge of biological human tissues. Generally, TOA-based localization can achieve much higher localization accuracy than other radio frequency-based localization techniques, whereas wireless signals transmitted from a WCE pass through various kinds of human body tissues, as a result, the propagation velocity inside a human body should be different from one in free space. Because the variation of propagation velocity is mainly affected by the relative permittivity of human body tissues, instead of pre-measurement for the relative permittivity in advance, we simultaneously estimate not only the WCE location but also the relative permittivity information. For this purpose, this paper first derives the relative permittivity estimation model with measured RSSI information. Then, we pay attention to a particle filter algorithm with the TOA-based localization and the RSSI-based relative permittivity estimation. Our computer simulation results demonstrates that the proposed tracking methods with the particle filter can accomplish an excellent localization accuracy of around 2 mm without prior information of the relative permittivity of the human body tissues.
Patel, Ashokkumar A; Gilbertson, John R; Parwani, Anil V; Dhir, Rajiv; Datta, Milton W; Gupta, Rajnish; Berman, Jules J; Melamed, Jonathan; Kajdacsy-Balla, Andre; Orenstein, Jan; Becich, Michael J
2006-05-05
Advances in molecular biology and growing requirements from biomarker validation studies have generated a need for tissue banks to provide quality-controlled tissue samples with standardized clinical annotation. The NCI Cooperative Prostate Cancer Tissue Resource (CPCTR) is a distributed tissue bank that comprises four academic centers and provides thousands of clinically annotated prostate cancer specimens to researchers. Here we describe the CPCTR information management system architecture, common data element (CDE) development, query interfaces, data curation, and quality control. Data managers review the medical records to collect and continuously update information for the 145 clinical, pathological and inventorial CDEs that the Resource maintains for each case. An Access-based data entry tool provides de-identification and a standard communication mechanism between each group and a central CPCTR database. Standardized automated quality control audits have been implemented. Centrally, an Oracle database has web interfaces allowing multiple user-types, including the general public, to mine de-identified information from all of the sites with three levels of specificity and granularity as well as to request tissues through a formal letter of intent. Since July 2003, CPCTR has offered over 6,000 cases (38,000 blocks) of highly characterized prostate cancer biospecimens, including several tissue microarrays (TMA). The Resource developed a website with interfaces for the general public as well as researchers and internal members. These user groups have utilized the web-tools for public query of summary data on the cases that were available, to prepare requests, and to receive tissues. As of December 2005, the Resource received over 130 tissue requests, of which 45 have been reviewed, approved and filled. Additionally, the Resource implemented the TMA Data Exchange Specification in its TMA program and created a computer program for calculating PSA recurrence. Building a biorepository infrastructure that meets today's research needs involves time and input of many individuals from diverse disciplines. The CPCTR can provide large volumes of carefully annotated prostate tissue for research initiatives such as Specialized Programs of Research Excellence (SPOREs) and for biomarker validation studies and its experience can help development of collaborative, large scale, virtual tissue banks in other organ systems.
DOT National Transportation Integrated Search
2000-05-01
This report responds to the request to review Amtrak's costs and capital investment needs. In particular, this report discusses changes since 1995 in Amtrak's operating costs, including labor costs, payments to freight railroads to access their track...
DOT National Transportation Integrated Search
2003-09-01
In January 2001, the Federal Highway Administration (FHWA) released a solicitation requesting "Cost Sharing Cooperative Agreements" to conduct operational tests to improve efficiencies in the intermodal freight operations and to establish the foundat...
NASA Astrophysics Data System (ADS)
Tavakoli, Vahid; Stoddard, Marcus F.; Amini, Amir A.
2013-03-01
Quantitative motion analysis of echocardiographic images helps clinicians with the diagnosis and therapy of patients suffering from cardiac disease. Quantitative analysis is usually based on TDI (Tissue Doppler Imaging) or speckle tracking. These methods are based on two independent techniques - the Doppler Effect and image registration, respectively. In order to increase the accuracy of the speckle tracking technique and cope with the angle dependency of TDI, herein, a combined approach dubbed TDIOF (Tissue Doppler Imaging Optical Flow) is proposed. TDIOF is formulated based on the combination of B-mode and Doppler energy terms in an optical flow framework and minimized using algebraic equations. In this paper, we report on validations with simulated, physical cardiac phantom, and in-vivo patient data. It is shown that the additional Doppler term is able to increase the accuracy of speckle tracking, the basis for several commercially available echocardiography analysis techniques.
Optical tracking of acoustic radiation force impulse-induced dynamics in a tissue-mimicking phantom
Bouchard, Richard R.; Palmeri, Mark L.; Pinton, Gianmarco F.; Trahey, Gregg E.; Streeter, Jason E.; Dayton, Paul A.
2009-01-01
Optical tracking was utilized to investigate the acoustic radiation force impulse (ARFI)-induced response, generated by a 5-MHz piston transducer, in a translucent tissue-mimicking phantom. Suspended 10-μm microspheres were tracked axially and laterally at multiple locations throughout the field of view of an optical microscope with 0.5-μm displacement resolution, in both dimensions, and at frame rates of up to 36 kHz. Induced dynamics were successfully captured before, during, and after the ARFI excitation at depths of up to 4.8 mm from the phantom’s proximal boundary. Results are presented for tracked axial and lateral displacements resulting from on-axis and off-axis (i.e., shear wave) acquisitions; these results are compared to matched finite element method modeling and independent ultrasonically based empirical results and yielded reasonable agreement in most cases. A shear wave reflection, generated by the proximal boundary, consistently produced an artifact in tracked displacement data later in time (i.e., after the initial ARFI-induced displacement peak). This tracking method provides high-frame-rate, two-dimensional tracking data and thus could prove useful in the investigation of complex ARFI-induced dynamics in controlled experimental settings. PMID:19894849
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
...The DOT invites the public and other Federal agencies to comment on a revision to a previously approved information collection concerning new requirements and procedures for grant payment request submission. DOT will submit the proposed renewal of information collection request to the Office of Management and Budget (OMB) for review, as required by the Paperwork Reduction Act of 1995 (PRA) (44 U.S.C. 3506 (c)(2)(A)). This notice sets forth new requirements and procedures for grantees that submit and receive payments from DOT Operating Administrations (OAs).\\1\\ DOT is updating systems that support grant payments and there will be changes to the way grantees complete and submit payment requests. Simplifying the DOT grant payment process will save both the grantee and the Federal Government time and expense that come with paper-based grant application and payment administration. Note: At this time, this requirement is not applicable to DOT grant recipients requesting payment electronically through the National Highway Traffic Safety Administration's Grant Tracking System (GTS), the Federal Highway Administration's Rapid Approval State Payment System (RASPS), or Federal Transit Administration (FTA) grant recipients requesting payment through the Electronic Clearing House Operation System (ECHO-Web). ---------------------------------------------------------------------------
CUDA-Accelerated Geodesic Ray-Tracing for Fiber Tracking
van Aart, Evert; Sepasian, Neda; Jalba, Andrei; Vilanova, Anna
2011-01-01
Diffusion Tensor Imaging (DTI) allows to noninvasively measure the diffusion of water in fibrous tissue. By reconstructing the fibers from DTI data using a fiber-tracking algorithm, we can deduce the structure of the tissue. In this paper, we outline an approach to accelerating such a fiber-tracking algorithm using a Graphics Processing Unit (GPU). This algorithm, which is based on the calculation of geodesics, has shown promising results for both synthetic and real data, but is limited in its applicability by its high computational requirements. We present a solution which uses the parallelism offered by modern GPUs, in combination with the CUDA platform by NVIDIA, to significantly reduce the execution time of the fiber-tracking algorithm. Compared to a multithreaded CPU implementation of the same algorithm, our GPU mapping achieves a speedup factor of up to 40 times. PMID:21941525
Glassy dynamics in three-dimensional embryonic tissues
Schötz, Eva-Maria; Lanio, Marcos; Talbot, Jared A.; Manning, M. Lisa
2013-01-01
Many biological tissues are viscoelastic, behaving as elastic solids on short timescales and fluids on long timescales. This collective mechanical behaviour enables and helps to guide pattern formation and tissue layering. Here, we investigate the mechanical properties of three-dimensional tissue explants from zebrafish embryos by analysing individual cell tracks and macroscopic mechanical response. We find that the cell dynamics inside the tissue exhibit features of supercooled fluids, including subdiffusive trajectories and signatures of caging behaviour. We develop a minimal, three-parameter mechanical model for these dynamics, which we calibrate using only information about cell tracks. This model generates predictions about the macroscopic bulk response of the tissue (with no fit parameters) that are verified experimentally, providing a strong validation of the model. The best-fit model parameters indicate that although the tissue is fluid-like, it is close to a glass transition, suggesting that small changes to single-cell parameters could generate a significant change in the viscoelastic properties of the tissue. These results provide a robust framework for quantifying and modelling mechanically driven pattern formation in tissues. PMID:24068179
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nowik, P; Bujila, R; Merzan, D
2015-06-15
Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CTmore » dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.« less
10 CFR 603.1100 - Contracting officer's post-award responsibilities.
Code of Federal Regulations, 2011 CFR
2011-01-01
... technical progress, financial status, and future program plans. (b) Tracking and processing of reports... progress reports, and patent reports. (c) Handling payment requests and related matters. For a TIA using advance payments, that includes reviews of progress to verify that there is continued justification for...
76 FR 18294 - Proposed Agency Information Collection Activities; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-01
... learns the condition of operating rules and practices with respect to trains and instructions provided by... Existing On-Track Roadway Maintenance Machines Conforming with Paragraph (a) of This Section. 214.507... stencils. Maintenance Machine (RMM). 214.511--Clearly Identifiable 644 railroads...... 3,700 identified 5...
Instructional Time Trends. Education Trends
ERIC Educational Resources Information Center
Woods, Julie Rowland
2015-01-01
For more than 30 years, Education Commission of the States has tracked instructional time and frequently receives requests for information about policies and trends. In this Education Trends report, Education Commission of the States addresses some of the more frequent questions, including the impact of instructional time on achievement, variation…
77 FR 19704 - Agency Information Collection Activities: Proposed Collection, Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-02
... relative to the disposition of the leased minerals. The ONRR financial accounting system is an integrated... royalty is appropriately paid, based on accurate production accounting on oil, gas, and geothermal... federally approved unit or communitization agreement. The ONRR financial accounting system tracks minerals...
75 FR 52993 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-30
... information system used to track case files involving internal agency investigations. 13. Department of... Inspection Service (N1-463-09-10, 1 item, 1 temporary item). Master files of an electronic information system... an electronic information system containing data that supports financial management and accounting...
76 FR 56002 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-09
... being requested, and the petitioner's arguments in favor of relief. Henry G. Peterson, a private..., 49 CFR 223.15, Requirements for existing passenger cars. Specifically, Mr. Peterson has petitioned... RPCX 8322. Mr. Peterson operates this car on approximately 130 miles of track owned by the Genesee...
77 FR 49817 - Proposed Information Collection Activity; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
... and Resources for Emotion and Social skill promotion (CARES) project: Tracking Participants. OMB No... skill promotion (CARES) project is an evaluation of three social emotional program enhancements within... providers will need if they are to increase Head Start's capacity to improve the social and emotional skills...
78 FR 28222 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... Approaches and Resources for Emotion and Social skill promotion (CARES) project: Tracking Participants... skill promotion (CARES) project is an evaluation of three social emotional program enhancements within... providers will need if they are to increase Head Start's capacity to improve the social and emotional skills...
NASA Technical Reports Server (NTRS)
1972-01-01
A Tracking and Data Relay Satellite System (TDRSS) concept for service of low and medium data rate user spacecraft has been defined. The TDRS system uses two geosynchronous dual spin satellites compatible with Delta 2914 to provide command, tracking, and telemetry service between multiple low earth orbiting users and a centrally located ground station. The low data rate user service capability via each TDRS is as follows: (1) forward link at UHF: voice to one user, commands to 20 users (sequential), range and range rate service, and (2) return link at VHF: voice from one user, data from 20 users (simultaneous), range and range rate return signals. The medium data rate user service via each TDRS is as follows: (1) forward link at S band: voice or command and tracking signals to one user, and (2) return link at S band: voice, data and tracking signals from one user "order wire" for high priority service requests (implemented with an earth coverage antenna).
Automated Planning for a Deep Space Communications Station
NASA Technical Reports Server (NTRS)
Estlin, Tara; Fisher, Forest; Mutz, Darren; Chien, Steve
1999-01-01
This paper describes the application of Artificial Intelligence planning techniques to the problem of antenna track plan generation for a NASA Deep Space Communications Station. Me described system enables an antenna communications station to automatically respond to a set of tracking goals by correctly configuring the appropriate hardware and software to provide the requested communication services. To perform this task, the Automated Scheduling and Planning Environment (ASPEN) has been applied to automatically produce antenna trucking plans that are tailored to support a set of input goals. In this paper, we describe the antenna automation problem, the ASPEN planning and scheduling system, how ASPEN is used to generate antenna track plans, the results of several technology demonstrations, and future work utilizing dynamic planning technology.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-28
.... Knowledgeable in the areas of dental implants, dental materials, periodontology, tissue engineering, and dental... and tissue based products, regenerative medicine and combination products. Blood Products..., immunology, blood banking, surgery, internal medicine, biochemistry, engineering, biological and physical...
78 FR 45490 - Department of State Acquisition Regulation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-29
... being added due to the need to obtain current data to support the Department of State (DOS) financial statements. From a financial accounting perspective, DOS must have a way of keeping track of its capital... DOSAR 652.245- 71, Accounting for Government Property, requests quarterly reporting of U.S. Department...
75 FR 14630 - Agency Information Collection Activities: Proposed Collection; Comments Requested
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... on a recurring basis. In the SCPS data collection program, felony defendants are tracked for up to 1 year with data collected on a variety of felony case processing characteristics. These include the... convicted, sentencing data are collected. The SCPS 2009 project also involves collecting aggregate...
75 FR 6641 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-10
... from members of the public is to make these submissions available for public viewing on the Internet at... is stored in the VRS database. It is used by the installation police in traffic and parking enforcement. The DESC Parking Administrator uses the information to track parking infractions, and to identify...
75 FR 12575 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-16
... licensed pursuant to 10 CFR Part 61 or equivalent Agreement State regulations. All generators, collectors... processors, contains information which facilitates tracking the identity of the waste generator. That... generators. The information provided on NRC Form 542 permits the States and Compacts to know the original...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... DEPARTMENT OF HOMELAND SECURITY Federal Emergency Management Agency [Docket ID: FEMA-2013-0014... Preparedness and Participation Survey used to identify progress and gaps in citizen and community preparedness... direction in Executive Order 13254 to study and track the progress of public service programs. Citizen Corps...
28 CFR 0.111B - Witness Security Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... tracking of such persons; and (8) Exempt procurement for services, materials, and supplies, and the... the Director knows or the request indicates that the person is under investigation for or has been... Marshals Service designated by the Director may: (1) Provide suitable documents to enable the person to...
77 FR 34004 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-08
... incidence rates, annual injury frequencies, and descriptive injury information for children under the age of... and descriptive injury information for farm operators and their employees 20 years of age or older... information is not collected, NIOSH's ability to track and evaluate the impact of its injury prevention...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-14
... be submitted to the Office of Management and Budget (OMB) for review and approval. Proposed... size to evaluate the measurement error structure of the diet and physical activity assessment... on cancer research, diagnosis, prevention and treatment. Dietary and physical activity data will be...
76 FR 13415 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-11
...) approval to conduct survey research to monitor the health care industry's awareness of, and preparation for, the transition to Version 5010 and ICD-10. The aggregated data obtained through the survey will help... tracking survey of populations charged with implementing Version 5010 and ICD-10 electronic transaction...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... National Veterans Sports Programs and Special Event Surveys Data Collection) Activity: Comment Request... needed to evaluate the National Veterans Sports Programs and Special Event Surveys Data Collection is... treatments are being offered, and tangible, quantitative results are being measured and tracked for continual...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... form in support of the scholarship application by academic professors/advisors. NOAA OEd student... grantees are required to update the student tracker database with the required student information. In... Tracking System database form, 17 hours; undergraduate application form, 8 hours; reference forms, 1 hour...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-22
... completion of a NOAA student scholar reference form in support of the scholarship application by academic... internal tracking purposes. NOAA OEd grantees are required to update the student tracker database with the... tracker database form, 16 hours; graduate application form, 8 hours; undergraduate application form, 8...
77 FR 31429 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-25
... request for a waiver of compliance from certain requirements of its safety standards. The South Carolina... from certain provisions of the Federal railroad safety regulations contained at 49 CFR Part 213. FRA... day interval between inspections if the track carries passenger trains or more than 10 million gross...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
... through primary processing; (2) to analyze the economic performance effects of current management measures; and (3) to analyze the economic performance effects of alternative management measures. The measures... used to track economic performance and to evaluate the economic effects of alternative management...
77 FR 39519 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-03
... compiled from various sources to track and monitor the effects of past nuclear tests on Armed Forces personnel. 3. Department of Energy, Federal Energy Regulatory Commission (N1- 138-12-2, 1 temporary item... temporary item). Project files, including working papers relating to product reports. 7. Department of Labor...
76 FR 38457 - Petition for Waiver of Compliance
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-30
...) conducts freight operations on 23 miles of this 33-mile rail line; and presently the only common track use... modifications requested above would follow the existing protocols such as good communication between HVRM and... is under Yard Limit Rules with good visibility conditions. The new petition states that HVRM operates...
75 FR 12329 - Proposed Information Collections; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-15
... Burden Hours: One (1). Title: Marks on Equipment and Structures, and Marks and Labels on Containers of... containers of beer are necessary to inform consumers of container contents and to identify the brewer and... these questionnaires to keep track of its customer service quality and progress, as well as to identify...
78 FR 6141 - Paperwork Reduction Act; Notice of Intent To Collect; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-29
...-Drug Media Campaign. Type and Title of Collections: Qualitative Research, OMB 3201-0011, uses focus...-0010, consists of 15-minute online interviews. Frequency: Qualitative Research and Copy Testing... teenagers. Estimated Burden: Qualitative Research, $19,800; Copy Testing, $16,500; Tracking Study, $37,700...
78 FR 57179 - Records Schedules; Availability and Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-17
... temporary items). Records of printing services. 7. Department of Labor, Bureau of Labor Statistics (DAA-0257... used to track the costs of highway construction. 12. Office of the Director of National Intelligence, Office of the Deputy Director of National Intelligence for Intelligence Integration (N1-576-11-12), 13...
Eye bank tissue utilization between endothelial keratoplasty and penetrating keratoplasty.
Croasdale, Christopher R; Barney, Erin; Warner, Evan J
2013-03-01
To determine rates of tissue use for corneal transplants via endothelial keratoplasty (EK) relative to penetrating keratoplasty (PK). Retrospective chart review of all cornea tissues (n = 3669) distributed from the Lions Eye Bank of Wisconsin for EK or PK from August 1, 2004 through July 31, 2009 (60 months). Rates of tissue use for EK relative to PK were determined both on a yearly basis and for the overall study period. Replacement frequency and time to subsequent surgery were established for each group. Donor tissue and recipient characteristics were compared between groups. Donor characteristics did not differ between the 2 groups; 11.9% of EK tissues failed and were replaced during the study period compared with 5.1% of PK tissues (P < 0.0001). Additional tissue for the same eye came at a mean of 174 days after an EK surgery compared with 558 days after a PK (P < 0.0001). Surgeons requesting tissue for EK increased each year, whereas the number of repeat tissue requests decreased over time. Additional tissues were required for recipients of EK more than twice as often as for recipients of PK, and replacement of EK grafts occurred at a mean of more than 1 year before replacement of PK grafts. This pattern of tissue utilization during the first 5 years of distribution for EK did not negatively affect the Lions Eye Bank of Wisconsin from meeting the surgeon demand for tissue in its service area. Eye banks may wish to monitor tissue utilization as part of their quality assurance program.
Murase, Tomohiko; Iwase, Akira; Komatsu, Kouji; Bayasula; Nakamura, Tomoko; Osuka, Satoko; Takikawa, Sachiko; Goto, Maki; Kotani, Tomomi; Kikkawa, Fumitaka
2018-02-01
To visualize and analyze follicle development in ovarian tissue culture using physiological concentrations of follicle-stimulating hormone (FSH) and luteinizing hormone (LH) in order to establish an ovarian tissue culture system that enables efficient in vitro growth of follicles. Ovarian tissues from 4-week-old female ICR mice were sliced and cultured. Images of ovarian tissues in culture were obtained at 24-h or 30-min intervals by using a microscope. The area of each follicle observed in the ovarian tissue slices was tracked and analyzed in association with oocyte maturation. We were able to track the development of each follicle using this culture system. Follicle growth was associated with oocyte maturation. Meiotically matured oocytes (MII) were obtained from 33% of all follicles investigated. Approximately, a quarter of follicles (24%) did not grow and resulted in atresia. Follicle dynamics were successfully visualized and analyzed in murine ovarian tissue culture. We were able to obtain mature oocytes from the fully grown follicles in vitro. This culture system would be helpful for efficient in vitro culturing of ovarian tissues.
Prakash, Gaurav; Agarwal, Amar; Kumar, Dhivya Ashok; Jacob, Soosan; Agarwal, Athiya; Maity, Amrita
2011-03-01
To evaluate the visual and refractive outcomes and expected benefits of Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking. This prospective, interventional case series comprised 122 eyes (70 patients). Pre- and postoperative assessment included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, and higher order aberrations. All patients underwent Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking using the Technolas 217z 100-Hz excimer platform (Technolas Perfect Vision GmbH). Follow-up was performed up to 6 months postoperatively. Theoretical benefit analysis was performed to evaluate the algorithm's outcomes compared to others. Preoperative spherocylindrical power was sphere -3.62 ± 1.60 diopters (D) (range: 0 to -6.75 D), cylinder -1.15 ± 1.00 D (range: 0 to -3.50 D), and spherical equivalent -4.19 ± 1.60 D (range: -7.75 to -2.00 D). At 6 months, 91% (111/122) of eyes were within ± 0.50 D of attempted correction. Postoperative UDVA was comparable to preoperative CDVA at 1 month (P=.47) and progressively improved at 6 months (P=.004). Two eyes lost one line of CDVA at 6 months. Theoretical benefit analysis revealed that of 101 eyes with astigmatism, 29 would have had cyclotorsion-induced astigmatism of ≥ 10% if iris recognition and dynamic rotational eye tracking were not used. Furthermore, the mean percentage decrease in maximum depth of ablation by using the Tissue Saving Treatment was 11.8 ± 2.9% over Aspheric, 17.8 ± 6.2% over Personalized, and 18.2 ± 2.8% over Planoscan algorithms. Tissue saving surface ablation with iris recognition and dynamic rotational eye tracking was safe and effective in this series of eyes. Copyright 2011, SLACK Incorporated.
A Finite-Element Method Model of Soft Tissue Response to Impulsive Acoustic Radiation Force
Palmeri, Mark L.; Sharma, Amy C.; Bouchard, Richard R.; Nightingale, Roger W.; Nightingale, Kathryn R
2010-01-01
Several groups are studying acoustic radiation force and its ability to image the mechanical properties of tissue. Acoustic radiation force impulse (ARFI) imaging is one modality using standard diagnostic ultrasound scanners to generate localized, impulsive, acoustic radiation forces in tissue. The dynamic response of tissue is measured via conventional ultrasonic speckle-tracking methods and provides information about the mechanical properties of tissue. A finite-element method (FEM) model has been developed that simulates the dynamic response of tissues, with and without spherical inclusions, to an impulsive acoustic radiation force excitation from a linear array transducer. These FEM models were validated with calibrated phantoms. Shear wave speed, and therefore elasticity, dictates tissue relaxation following ARFI excitation, but Poisson’s ratio and density do not significantly alter tissue relaxation rates. Increased acoustic attenuation in tissue increases the relative amount of tissue displacement in the near field compared with the focal depth, but relaxation rates are not altered. Applications of this model include improving image quality, and distilling material and structural information from tissue’s dynamic response to ARFI excitation. Future work on these models includes incorporation of viscous material properties and modeling the ultrasonic tracking of displaced scatterers. PMID:16382621
Cell Migration in Tissues: Explant Culture and Live Imaging.
Staneva, Ralitza; Barbazan, Jorge; Simon, Anthony; Vignjevic, Danijela Matic; Krndija, Denis
2018-01-01
Cell migration is a process that ensures correct cell localization and function in development and homeostasis. In disease such as cancer, cells acquire an upregulated migratory capacity that leads to their dissemination throughout the body. Live imaging of cell migration allows for better understanding of cell behaviors in development, adult tissue homeostasis and disease. We have optimized live imaging procedures to track cell migration in adult murine tissue explants derived from: (1) healthy gut; (2) primary intestinal carcinoma; and (3) the liver, a common metastatic site. To track epithelial cell migration in the gut, we generated an inducible fluorescent reporter mouse, enabling us to visualize and track individual cells in unperturbed gut epithelium. To image intratumoral cancer cells, we use a spontaneous intestinal cancer model based on the activation of Notch1 and deletion of p53 in the mouse intestinal epithelium, which gives rise to aggressive carcinoma. Interaction of cancer cells with a metastatic niche, the mouse liver, is addressed using a liver colonization model. In summary, we describe a method for long-term 3D imaging of tissue explants by two-photon excitation microscopy. Explant culturing and imaging can help understand dynamic behavior of cells in homeostasis and disease, and would be applicable to various tissues.
Coding and traceability: cells and tissues in North America.
Brubaker, Scott A; Wilson, Diane
2010-11-01
Cell and tissue banking professionals in North America have long understood the value of labeling their allografts with descriptive names that make them easily recognized. They have also understood that advantages exist in possessing the capability to track them internally and externally to better understand tissue handling from donation through distribution. An added insight that can assist with strategic planning is to know who uses them, how many, and for what purpose or application. Uniquely coding allografts naturally aids tracking in event of recall or the rare need to link them if implicated in an adverse outcome report. These values relate to an ability or inability to sufficiently track specific cell/tissue types throughout the allograft's lifetime. These concepts easily fit into the functions of a Quality Program and promote recipient safety. It is management oversight that drives the direction taken and either optimizes this knowledge or limits it. How concepts related to coding and tracing human cells and tissues for transplantation have evolved in North America, and where they may be headed, are described in this manuscript. Many protocols are in place but they exist in numerous operational silos. Quality Management System concepts should drive decision-making and include considerations for future planning beyond our own professional lifetimes.
Casanova, Fernando; Carney, Paul R; Sarntinoranont, Malisa
2014-11-30
Convection enhanced delivery (CED) infuses drugs directly into brain tissue. Needle insertion is required and results in tissue damage which can promote flowback along the needle track and improper targeting. The goal of this study was to evaluate friction stress (calculated from needle insertion force) as a measure of tissue contact and damage during needle insertion for varying insertion speeds. Forces and surface dimpling during needle insertion were measured in rat brain in vivo. Needle retraction forces were used to calculate friction stresses. These measures were compared to track damage from a previous study. Differences between brain tissues and soft hydrogels were evaluated for varying insertion speeds: 0.2, 2, and 10mm/s. In brain tissue, average insertion force and surface dimpling increased with increasing insertion speed. Average friction stress along the needle-tissue interface decreased with insertion speed (from 0.58 ± 0.27 to 0.16 ± 0.08 kPa). Friction stress varied between brain regions: cortex (0.227 ± 0.27 kPa), external capsule (0.222 ± 0.19 kPa), and CPu (0.383 ± 0.30 kPa). Hydrogels exhibited opposite trends for dimpling and friction stress with insertion speed. Previously, increasing needle damage with insertion speed has been measured with histological methods. Friction stress appears to decrease with increasing tissue damage and decreasing tissue contact, providing the potential for in vivo and real time evaluation along the needle track. Force derived friction stress decreased with increasing insertion speed and was smaller within white matter regions. Hydrogels exhibited opposite trends to brain tissue. Copyright © 2014 Elsevier B.V. All rights reserved.
Skornitzke, Stephan; Fritz, Franziska; Mayer, Philipp; Koell, Marco; Hansen, Jens; Pahn, Gregor; Hackert, Thilo; Kauczor, Hans-Ulrich; Stiller, Wolfram
2018-05-01
Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion. Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kV p with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kV p image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time. Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min -1 , respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (r max = 0.89; p < 0.05). Differences in iodine concentrations between healthy pancreatic tissue and carcinoma were statistically significant for DECT acquisitions corresponding to trigger delays of 15-21 s (p < 0.05). An acquisition window between 15 and 21 s after exceeding bolus tracking threshold shows promising results for acquisition of DECT iodine maps as an alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.
Scheduling the future NASA Space Network: Experiences with a flexible scheduling prototype
NASA Technical Reports Server (NTRS)
Happell, Nadine; Moe, Karen L.; Minnix, Jay
1993-01-01
NASA's Space Network (SN) provides telecommunications and tracking services to low earth orbiting spacecraft. One proposal for improving resource allocation and automating conflict resolution for the SN is the concept of flexible scheduling. In this concept, each Payload Operations Control Center (POCC) will possess a Space Network User POCC Interface (SNUPI) to support the development and management of flexible requests. Flexible requests express the flexibility, constraints, and repetitious nature of the user's communications requirements. Flexible scheduling is expected to improve SN resource utilization and user satisfaction, as well as reduce the effort to produce and maintain a schedule. A prototype testbed has been developed to better understand flexible scheduling as it applies to the SN. This testbed consists of a SNUPI workstation, an SN scheduler, and a flexible request language that conveys information between the two systems. All three are being evaluated by operations personnel. Benchmark testing is being conducted on the scheduler to quantify the productivity improvements achieved with flexible requests.
Distributed cluster management techniques for unattended ground sensor networks
NASA Astrophysics Data System (ADS)
Essawy, Magdi A.; Stelzig, Chad A.; Bevington, James E.; Minor, Sharon
2005-05-01
Smart Sensor Networks are becoming important target detection and tracking tools. The challenging problems in such networks include the sensor fusion, data management and communication schemes. This work discusses techniques used to distribute sensor management and multi-target tracking responsibilities across an ad hoc, self-healing cluster of sensor nodes. Although miniaturized computing resources possess the ability to host complex tracking and data fusion algorithms, there still exist inherent bandwidth constraints on the RF channel. Therefore, special attention is placed on the reduction of node-to-node communications within the cluster by minimizing unsolicited messaging, and distributing the sensor fusion and tracking tasks onto local portions of the network. Several challenging problems are addressed in this work including track initialization and conflict resolution, track ownership handling, and communication control optimization. Emphasis is also placed on increasing the overall robustness of the sensor cluster through independent decision capabilities on all sensor nodes. Track initiation is performed using collaborative sensing within a neighborhood of sensor nodes, allowing each node to independently determine if initial track ownership should be assumed. This autonomous track initiation prevents the formation of duplicate tracks while eliminating the need for a central "management" node to assign tracking responsibilities. Track update is performed as an ownership node requests sensor reports from neighboring nodes based on track error covariance and the neighboring nodes geo-positional location. Track ownership is periodically recomputed using propagated track states to determine which sensing node provides the desired coverage characteristics. High fidelity multi-target simulation results are presented, indicating the distribution of sensor management and tracking capabilities to not only reduce communication bandwidth consumption, but to also simplify multi-target tracking within the cluster.
Design of a tracking device for on-line dose monitoring in hadrontherapy
NASA Astrophysics Data System (ADS)
Battistoni, G.; Collamati, F.; De Lucia, E.; Faccini, R.; Marafini, M.; Mattei, I.; Muraro, S.; Paramatti, R.; Patera, V.; Pinci, D.; Rucinski, A.; Russomando, A.; Sarti, A.; Sciubba, A.; Solfaroli Camillocci, E.; Toppi, M.; Traini, G.; Voena, C.
2017-02-01
Hadrontherapy is a technique for cancer treatment that exploits ion beams (mostly protons and carbons). A critical issue is the accuracy that is achievable when monitoring the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a tracking device, developed in the framework of the INSIDE project [1], capable of monitoring in real time the longitudinal profile of the dose delivered in the patient. This is possible by detecting the secondary particles produced by the interaction of the beam in the tissues. The position of the Bragg peak can be correlated to the charged particles emission point distribution measurement. The tracking device will be able to provide a fast response on the dose pattern by tracking the secondary charged fragments. The tracks are detected using 6 planes of scintillating fibers, providing the 3D coordinates of the track intersection with each plane. The fibers planes are followed by a plastic scintillator and by a small calorimeter built with a pixelated Lutetium Fine Silicate (LFS) crystal. A complete detector simulation, followed by the event reconstruction, has been performed to determine the achievable monitoring spatial resolution.
Viscoelastic Property Measurement in Thin Tissue Constructs Using Ultrasound
Liu, Dalong; Ebbini, Emad S.
2010-01-01
We present a dual-element concave ultrasound transducer system for generating and tracking of localized tissue displacements in thin tissue constructs on rigid substrates. The system is comprised of a highly focused PZT-4 5-MHz acoustic radiation force (ARF) transducer and a confocal 25-MHz polyvinylidene fluoride imaging transducer. This allows for the generation of measurable displacements in tissue samples on rigid substrates with thickness values down to 500 µm. Impulse-like and longer duration sine-modulated ARF pulses are possible with intermittent M-mode data acquisition for displacement tracking. The operations of the ARF and imaging transducers are strictly synchronized using an integrated system for arbitrary waveform generation and data capture with a shared timebase. This allows for virtually jitter-free pulse-echo data well suited for correlation-based speckle tracking. With this technique we could faithfully capture the entire dynamics of the tissue axial deformation at pulse-repetition frequency values up to 10 kHz. Spatio-temporal maps of tissue displacements in response to a variety of modulated ARF beams were produced in tissue-mimicking elastography phantoms on rigid substrates. The frequency response was measured for phantoms with different modulus and thickness values. The frequency response exhibited resonant behavior with the resonance frequency being inversely proportional to the sample thickness. This resonant behavior can be used in obtaining high-contrast imaging using magnitude and phase response to sinusoidally modulated ARF beams. Furthermore, a second order forced harmonic oscillator (FHO) model was shown to capture this resonant behavior. Based on the FHO model, we used the extended Kalman filter (EKF) for tracking the apparent modulus and viscosity of samples subjected to dc and sinusoidally modulated ARF. The results show that the stiffness (apparent modulus) term in the FHO is largely time-invariant and can be estimated robustly using the EKF. On the other hand, the damping (apparent viscosity) is time varying. These findings were confirmed by comparing the magnitude response of the FHO (with parameters obtained using the EKF) with the measured ones for different thin tissue constructs. PMID:18334343
Lightning Tracking Tool for Assessment of Total Cloud Lightning within AWIPS II
NASA Technical Reports Server (NTRS)
Burks, Jason E.; Stano, Geoffrey T.; Sperow, Ken
2014-01-01
Total lightning (intra-cloud and cloud-to-ground) has been widely researched and shown to be a valuable tool to aid real-time warning forecasters in the assessment of severe weather potential of convective storms. The trend of total lightning has been related to the strength of a storm's updraft. Therefore a rapid increase in total lightning signifies the strengthening of the parent thunderstorm. The assessment of severe weather potential occurs in a time limited environment and therefore constrains the use of total lightning. A tool has been developed at NASA's Short-term Prediction Research and Transition (SPoRT) Center to assist in quickly analyzing the total lightning signature of multiple storms. The development of this tool comes as a direct result of forecaster feedback from numerous assessments requesting a real-time display of the time series of total lightning. This tool also takes advantage of the new architecture available within the AWIPS II environment. SPoRT's lightning tracking tool has been tested in the Hazardous Weather Testbed (HWT) Spring Program and significant changes have been made based on the feedback. In addition to the updates in response to the HWT assessment, the lightning tracking tool may also be extended to incorporate other requested displays, such as the intra-cloud to cloud-to-ground ratio as well as incorporate the lightning jump algorithm.
NASA Astrophysics Data System (ADS)
Wu, Tsai-Jung; Tzeng, Yan-Kai; Chang, Wei-Wei; Cheng, Chi-An; Kuo, Yung; Chien, Chin-Hsiang; Chang, Huan-Cheng; Yu, John
2013-09-01
Lung stem/progenitor cells are potentially useful for regenerative therapy, for example in repairing damaged or lost lung tissue in patients. Several optical imaging methods and probes have been used to track how stem cells incorporate and regenerate themselves in vivo over time. However, these approaches are limited by photobleaching, toxicity and interference from background tissue autofluorescence. Here we show that fluorescent nanodiamonds, in combination with fluorescence-activated cell sorting, fluorescence lifetime imaging microscopy and immunostaining, can identify transplanted CD45-CD54+CD157+ lung stem/progenitor cells in vivo, and track their engraftment and regenerative capabilities with single-cell resolution. Fluorescent nanodiamond labelling did not eliminate the cells' properties of self-renewal and differentiation into type I and type II pneumocytes. Time-gated fluorescence imaging of tissue sections of naphthalene-injured mice indicates that the fluorescent nanodiamond-labelled lung stem/progenitor cells preferentially reside at terminal bronchioles of the lungs for 7 days after intravenous transplantation.
Bromelain ameliorates the wound microenvironment and improves the healing of firearm wounds.
Wu, Si-Yu; Hu, Wei; Zhang, Bo; Liu, Shuai; Wang, Jian-Min; Wang, Ai-Min
2012-08-01
In a previous study, we proposed a new therapy using topical bromelain as a supplement to simple wound-track incision for the debridement of firearm wounds. This enzymatic debridement greatly simplified the management of high-velocity gunshot wounds in a pig model, and bromelain was confirmed to improve wound healing. The purpose of the present study was to investigate the effect of bromelain on the microenvironment of firearm wounds. Sixteen Chinese landrace pigs wounded by high-velocity projectiles were divided randomly into four groups: wound incision (group I), incision + bromelain (group IB), wound excision (group E), and control. Blood perfusion, oxygen partial pressure (pO(2)), and the content of tumor necrosis factor (TNF)-α and transforming growth factor (TGF)-β in wound-track tissue were measured. Wound healing was also noted. The recovery of blood perfusion in tissue and pO(2) in wound tracks was significantly more rapid in group IB and group E than in group I and control. The tissue level of TNF-α was significantly lower in group IB than in group I and control 48 h and 72 h post-wounding, and was lower than in group E 48 h post-wounding. The tissue level of TGF-β in group IB was sustained at a significantly higher level than in the other three groups. Wound healing time was also shorter in group IB. Enzymatic debridement using topical bromelain in incised wound tracks accelerates the recovery of blood perfusion, pO(2) in wound tissue, controls the expression of TNF-α and raises the expression of TGF-β. Copyright © 2012 Elsevier Inc. All rights reserved.
76 FR 31968 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
.... Proposed Project: SAMHSA SOAR Web-Based Data Form--NEW In 2009 the Substance Abuse and Mental Health... in all states. SOAR's primary objective is to improve the allowance rate for Social Security... Center under SAMHSA's direction developed a web-based data form that case managers can use to track the...
76 FR 51044 - Agency Information Collection Activities: Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
.... Project: SAMHSA SOAR Web-Based Data Form--NEW In 2009 the Substance Abuse and Mental Health Services... states. SOAR's primary objective is to improve the allowance rate for Social Security Administration (SSA... SAMHSA's direction developed a web-based data form that case managers can use to track the progress of...
Brocato, Lori; Hirschl, Nancy; Padfield, Stanley
2010-01-01
To meet the challenges presented by recovery audit contractors (RACs), hospitals should perform six tasks that require appropriate investments in staff: conduct a financial risk assessment of the impact of RAC reviews on the organization; establish a RAC team and assign a coordinator; receive and fill RAC requests; track RAC activity; manage RAC appeals; analyze RAC audit outcomes.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-13
... carriers, including each carrier operating light rail or heavy rail transit service on track that is part of the general railroad system of transportation and rail transit systems. Also, these persons are... any threat information. In addition, freight railroad carriers and the affected shippers and receivers...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-15
... affected agencies concerning the proposed collection of information to: 1. Evaluate whether the proposed... technology, e.g., permitting electronic submission of responses. This Notice also lists the following... residents and Attendance at or planning of community events, and H. Adding a new section to track aging in...
Framework for Sustaining Innovation at Baker Library, Harvard Business School
ERIC Educational Resources Information Center
Dolan, Meghan; Hemment, Michael; Oliver, Stephanie
2017-01-01
Baker Library at Harvard Business School is increasingly asked by the school's faculty to create custom digital information products to enhance course assignments and to find novel ways of electronically disseminating faculty research. In order to prioritize these requests, as well as facilitate, manage, and track the resulting projects, the…
77 FR 34400 - Agency Information Collection Activities: Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-11
... warnings and notification to the public of volcanic activity in the U.S. in order to reduce the loss of... eruptions will be directed towards a web form allowing them to fill in ash fall information and submit the... track eruption clouds and associated fallout downwind. These reports from the public will also give...
77 FR 48123 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-13
...) Whether the collection of information is necessary for the proper performance of the functions of the...: Food Safety Education Campaign Post-Wave Tracking Survey. OMB Control Number: 0583-New. Summary of... functions of the Secretary as provided in the Federal Meat Inspection Act (FMIA) (21 U.S.C. 601 et. seq...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-23
... pet food, and that FDA conducts inspections of pet food manufacturing establishments. However, USDA is... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0368... Request; Pet Event Tracking Network--State, Federal Cooperation To Prevent Spread of Pet Food Related...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
...-reported prevention behaviors. The survey will be fielded once prior to launch of materials, and then again... audit of existing research and statistics surrounding the issue and prevention behaviors. Following this... illness and safe food handling behaviors held by the target audience. These research sessions were...
Adult stem cell lineage tracing and deep tissue imaging
Fink, Juergen; Andersson-Rolf, Amanda; Koo, Bon-Kyoung
2015-01-01
Lineage tracing is a widely used method for understanding cellular dynamics in multicellular organisms during processes such as development, adult tissue maintenance, injury repair and tumorigenesis. Advances in tracing or tracking methods, from light microscopy-based live cell tracking to fluorescent label-tracing with two-photon microscopy, together with emerging tissue clearing strategies and intravital imaging approaches have enabled scientists to decipher adult stem and progenitor cell properties in various tissues and in a wide variety of biological processes. Although technical advances have enabled time-controlled genetic labeling and simultaneous live imaging, a number of obstacles still need to be overcome. In this review, we aim to provide an in-depth description of the traditional use of lineage tracing as well as current strategies and upcoming new methods of labeling and imaging. [BMB Reports 2015; 48(12): 655-667] PMID:26634741
ProteinTracker: an application for managing protein production and purification
2012-01-01
Background Laboratories that produce protein reagents for research and development face the challenge of deciding whether to track batch-related data using simple file based storage mechanisms (e.g. spreadsheets and notebooks), or commit the time and effort to install, configure and maintain a more complex laboratory information management system (LIMS). Managing reagent data stored in files is challenging because files are often copied, moved, and reformatted. Furthermore, there is no simple way to query the data if/when questions arise. Commercial LIMS often include additional modules that may be paid for but not actually used, and often require software expertise to truly customize them for a given environment. Findings This web-application allows small to medium-sized protein production groups to track data related to plasmid DNA, conditioned media samples (supes), cell lines used for expression, and purified protein information, including method of purification and quality control results. In addition, a request system was added that includes a means of prioritizing requests to help manage the high demand of protein production resources at most organizations. ProteinTracker makes extensive use of existing open-source libraries and is designed to track essential data related to the production and purification of proteins. Conclusions ProteinTracker is an open-source web-based application that provides organizations with the ability to track key data involved in the production and purification of proteins and may be modified to meet the specific needs of an organization. The source code and database setup script can be downloaded from http://sourceforge.net/projects/proteintracker. This site also contains installation instructions and a user guide. A demonstration version of the application can be viewed at http://www.proteintracker.org. PMID:22574679
Liao, Naishun; Wu, Ming; Pan, Fan; Lin, Jiumao; Li, Zuanfang; Zhang, Da; Wang, Yingchao; Zheng, Youshi; Peng, Jun; Liu, Xiaolong; Liu, Jingfeng
2016-01-05
Tracking and monitoring of cells in vivo after transplantation can provide crucial information for stem cell therapy. Magnetic resonance imaging (MRI) combined with contrast agents is believed to be an effective and non-invasive technique for cell tracking in living bodies. However, commercial superparamagnetic iron oxide nanoparticles (SPIONs) applied to label cells suffer from shortages such as potential toxicity, low labeling efficiency, and low contrast enhancing. Herein, the adipose tissue-derived stem cells (ADSCs) were efficiently labeled with SPIONs coated with poly (dopamine) (SPIONs cluster@PDA), without affecting their viability, proliferation, apoptosis, surface marker expression, as well as their self-renew ability and multi-differentiation potential. The labeled cells transplanted into the mice through tail intravenous injection exhibited a negative enhancement of the MRI signal in the damaged liver-induced by carbon tetrachloride, and subsequently these homed ADSCs with SPIONs cluster@PDA labeling exhibited excellent repair effects to the damaged liver. Moreover, the enhanced target-homing to tissue of interest and repair effects of SPIONs cluster@PDA-labeled ADSCs could be achieved by use of external magnetic field in the excisional skin wound mice model. Therefore, we provide a facile, safe, noninvasive and sensitive method for external magnetic field targeted delivery and MRI based tracking of transplanted cells in vivo.
Use of fluorescent ANTS to examine the BBB-permeability of polysaccharide
Christopher, Kevin; Makani, Vishruti; Judy, Wesley; Lee, Erica; Chiaia, Nicolas; Kim, Dong Shik; Park, Joshua
2015-01-01
Recently, some polysaccharides showed therapeutic potentials for the treatment of neurodegenerative diseases while the most important property, their permeability to the blood brain barrier (BBB) that sheathes the brain and spinal cord, is not yet determined. The determination has been delayed by the difficulty in tracking a target polysaccharide among endogenous polysaccharides in animal. We developed an easy way to examine the BBB-permeability and, possibly, tissue distribution of a target polysaccharide in animal. We tagged a polysaccharide with fluorescent 8-aminonaphthalene-1,3,6-trisulfonic acid disodium salt (ANTS) for tracking. We also developed a simple method to separate ANTS-tagged polysaccharide from unconjugated free ANTS using 75% ethanol. After ANTS-polysaccharide was intra-nasally administered into animals, we could quantify the amounts of ANTS-polysaccharide in the brain and the serum by fluorocytometry. We could also separate free ANTS-polysaccharide from serum proteins using trichloroacetic acid (TCA) and 75% ethanol. Our method will help to track a polysaccharide in animal easily. • ANTS-labeling is less tedious than but as powerful as radiolabeling for tracking a target polysaccharide in animal. • Our simple method can separate structurally intact ANTS-polysaccharide from animal serum and tissues. • This method is good for the fluorometry-based measurement of ANTS-conjugated macromolecules in tissues. PMID:25914873
NASA Astrophysics Data System (ADS)
Liao, Naishun; Wu, Ming; Pan, Fan; Lin, Jiumao; Li, Zuanfang; Zhang, Da; Wang, Yingchao; Zheng, Youshi; Peng, Jun; Liu, Xiaolong; Liu, Jingfeng
2016-01-01
Tracking and monitoring of cells in vivo after transplantation can provide crucial information for stem cell therapy. Magnetic resonance imaging (MRI) combined with contrast agents is believed to be an effective and non-invasive technique for cell tracking in living bodies. However, commercial superparamagnetic iron oxide nanoparticles (SPIONs) applied to label cells suffer from shortages such as potential toxicity, low labeling efficiency, and low contrast enhancing. Herein, the adipose tissue-derived stem cells (ADSCs) were efficiently labeled with SPIONs coated with poly (dopamine) (SPIONs cluster@PDA), without affecting their viability, proliferation, apoptosis, surface marker expression, as well as their self-renew ability and multi-differentiation potential. The labeled cells transplanted into the mice through tail intravenous injection exhibited a negative enhancement of the MRI signal in the damaged liver-induced by carbon tetrachloride, and subsequently these homed ADSCs with SPIONs cluster@PDA labeling exhibited excellent repair effects to the damaged liver. Moreover, the enhanced target-homing to tissue of interest and repair effects of SPIONs cluster@PDA-labeled ADSCs could be achieved by use of external magnetic field in the excisional skin wound mice model. Therefore, we provide a facile, safe, noninvasive and sensitive method for external magnetic field targeted delivery and MRI based tracking of transplanted cells in vivo.
9 CFR 54.11 - Approval of laboratories to run official scrapie tests and official genotype tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... request approval to conduct one or more types of scrapie test or genotype test on one or more types of... type of test and for each type of tissue for which they request approval. (c) The Administrator may... the laboratory and shall give the director an opportunity to respond. If there are conflicts as to any...
Propofol Induction's Effect on Cardiac Function
2015-03-31
This Study Was Focused to Evaluate Feasibility of Doppler Tissue Monitoring During the Induction Anesthesia,; and Evaluate Routine Propofol Induction's Effect on Myocardial Tissue Motion, Using Non-invasive Doppler Tissue and 2D Speckle Tracking Imaging.; This is the First Study, to Our Knowledge, Which Has Evaluated the Possible Impact of Propofol Induction on LV Function.
77 FR 75169 - Silver Nanoparticles (AgNPs); Information and Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-19
... control measures (e.g., engineering controls, work practices, PPE) that are being used in workplaces where... and tissues, (2) decrements in lung function and induction of inflammatory responses, and (3... and tissues when administered via gavage to Sprague-Dawley and F344 rats for 28 and 90 days [Kim et al...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-23
... international biobanks. The survey will collect a combination of structured, quantitative, and free-text descriptive data that characterize the type and maturity of respondent biobanks, their sources of funding, and... survey is to collect information regarding the challenges that human tissue biobanks encounter in...
Xu, Najia; Lei, Xi; Liu, Lixin
2011-09-24
The recruitment of circulating leukocytes from blood stream to the inflamed tissue is a crucial and complex process of inflammation(1,2). In the postcapillary venules of inflamed tissue, leukocytes initially tether and roll on the luminal surface of venular wall. Rolling leukocytes arrest on endothelium and undergo firm adhesion in response to chemokine or other chemoattractants on the venular surface. Many adherent leukocytes relocate from the initial site of adhesion to the junctional extravasation site in endothelium, a process termed intraluminal crawling(3). Following crawling, leukocytes move across endothelium (transmigration) and migrate in extravascular tissue toward the source of chemoattractant (chemotaxis)(4). Intravital microscopy is a powerful tool for visualizing leukocyte-endothelial cell interactions in vivo and revealing cellular and molecular mechanisms of leukocyte recruitment(2,5). In this report, we provide a comprehensive description of using brightfield intravital microscopy to visualize and determine the detailed processes of neutrophil recruitment in mouse cremaster muscle in response to the gradient of a neutrophil chemoattractant. To induce neutrophil recruitment, a small piece of agarose gel (~1-mm(3) size) containing neutrophil chemoattractant MIP-2 (CXCL2, a CXC chemokine) or WKYMVm (Trp-Lys-Tyr-Val-D-Met, a synthetic analog of bacterial peptide) is placed on the muscle tissue adjacent to the observed postcapillary venule. With time-lapsed video photography and computer software ImageJ, neutrophil intraluminal crawling on endothelium, neutrophil transendothelial migration and the migration and chemotaxis in tissue are visualized and tracked. This protocol allows reliable and quantitative analysis of many neutrophil recruitment parameters such as intraluminal crawling velocity, transmigration time, detachment time, migration velocity, chemotaxis velocity and chemotaxis index in tissue. We demonstrate that using this protocol, these neutrophil recruitment parameters can be stably determined and the single cell locomotion conveniently tracked in vivo.
Robust intravascular optical coherence elastography driven by acoustic radiation pressure
NASA Astrophysics Data System (ADS)
van Soest, Gijs; Bouchard, Richard R.; Mastik, Frits; de Jong, Nico; van der Steen, Anton F. W.
2007-07-01
High strain spots in the vessel wall indicate the presence of vulnerable plaques. The majority of acute cardiovascular events are preceded by rupture of such a plaque in a coronary artery. Intracoronary optical coherence tomography (OCT) can be extended, in principle, to an elastography technique, mapping the strain in the vascular wall. However, the susceptibility of OCT to frame-to-frame decorrelation, caused by tissue and catheter motion, inhibits reliable tissue displacement tracking and has to date obstructed the development of OCT-based intravascular elastography. We introduce a new technique for intravascular optical coherence elastography, which is robust against motion artifacts. Using acoustic radiation force, we apply a pressure to deform the tissue synchronously with the line scan rate of the OCT instrument. Radial tissue displacement can be tracked based on the correlation between adjacent lines, instead of subsequent frames in conventional elastography. The viability of the method is demonstrated with a simulation study. The root mean square (rms) error of the displacement estimate is 0.55 μm, and the rms error of the strain is 0.6%. It is shown that high-strain spots in the vessel wall, such as observed at the sites of vulnerable atherosclerotic lesions, can be detected with the technique. Experiments to realize this new elastographic method are presented. Simultaneous optical and ultrasonic pulse-echo tracking demonstrate that the material can be put in a high-frequency oscillatory motion with an amplitude of several micrometers, more than sufficient for accurate tracking with OCT. The resulting data are used to optimize the acoustic pushing sequence and geometry.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-04
... Development Center in Massachusetts so that it can be correctly identified through DNA analysis. (Since the... distinguished from each other. DNA analysis is the only way to accurately identify these insects.) The PPQ or... regulatory officials to identify and track specific specimens through the DNA identification tests that we...
78 FR 35610 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-13
... Defense. NM05720-1 System name: FOIA Request/Appeal Files and Tracking System (April 2, 2008, 73 FR 17961...: Delete entry and replace with ``Records are accessed by custodian of the record system and by persons... cabinets or rooms, which are not viewable by individuals who do not have a need to know. Computerized...
76 FR 31008 - CSX Transportation, Inc.-Abandonment Exemption-in Erie County, NY
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-27
... Running Track, between milepost QCQ 5.02 near E. Ferry Street and milepost QCQ 5.58 near E. Delavan Avenue....27(c)(2),\\2\\ and trail use/rail banking requests under 49 CFR 1152.29 must be filed by June 6, 2011... the public. Environmental, historic preservation, public use, or trail use/rail banking conditions...
Don't Settle: Leslie Monsalve-Jones--New Mexico State Library
ERIC Educational Resources Information Center
Library Journal, 2005
2005-01-01
Leslie Monsalve-Jones is a library technician with the New Mexico State Library, responsible for claiming documents that state agencies don't submit. She also maintains the collection and can immediately track down any requested document. In short, she is the kind of worker whose price is above rubies but whose pay is slightly above pebbles. And…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-10
... of Innovation and Improvement (OII). ACTION: Notice. SUMMARY: In accordance with the Paperwork... reporting mechanism for grantee budgets, the G5 team developed a new electronic budget form for grantees to... developed in G5 serves as the mechanism for grantees to report expenditures and track their spending in...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-23
... deemed to be the most appropriate method at this stage of research on LSPs. A total of 10 states will be... is in need of filling. A qualitative study that involves a brief pre-interview questionnaire followed... LSPs, and types of management information systems and provider tracking systems at the AAA level. A...
Tracking of adipose tissue-derived progenitor cells using two magnetic nanoparticle types
NASA Astrophysics Data System (ADS)
Kasten, Annika; Siegmund, Birte J.; Grüttner, Cordula; Kühn, Jens-Peter; Frerich, Bernhard
2015-04-01
Magnetic resonance imaging (MRI) is to be considered as an emerging detection technique for cell tracking experiments to evaluate the fate of transplanted progenitor cells and develop successful cell therapies for tissue engineering. Adipose tissue engineering using adipose tissue-derived progenitor cells has been advocated for the cure of soft tissue defects or for persistent soft tissue augmentation. Adipose tissue-derived progenitor cells were differentiated into the adipogenic lineage and labeled with two different types of magnetic iron oxide nanoparticles in varying concentrations which resulted in a concentration-dependent reduction of gene expression of adipogenic differentiation markers, adiponectin and fatty acid-binding protein 4 (FABP4), whereas the metabolic activity was not altered. As a result, only low nanoparticle concentrations for labeling were used for in vivo experiments. Cells were seeded onto collagen scaffolds and subcutaneously implanted into severe combined immunodeficient (SCID) mice. At 24 h as well as 28 days after implantation, MRI analyses were performed visualizing nanoparticle-labeled cells using T2-weighted sequences. The quantification of absolute volume of the scaffolds revealed a decrease of volume over time in all experimental groups. The distribution of nanoparticle-labeled cells within the scaffolds varied likewise over time.
Noninvasive metabolic imaging of engineered 3D human adipose tissue in a perfusion bioreactor.
Ward, Andrew; Quinn, Kyle P; Bellas, Evangelia; Georgakoudi, Irene; Kaplan, David L
2013-01-01
The efficacy and economy of most in vitro human models used in research is limited by the lack of a physiologically-relevant three-dimensional perfused environment and the inability to noninvasively quantify the structural and biochemical characteristics of the tissue. The goal of this project was to develop a perfusion bioreactor system compatible with two-photon imaging to noninvasively assess tissue engineered human adipose tissue structure and function in vitro. Three-dimensional (3D) vascularized human adipose tissues were engineered in vitro, before being introduced to a perfusion environment and tracked over time by automated quantification of endogenous markers of metabolism using two-photon excited fluorescence (TPEF). Depth-resolved image stacks were analyzed for redox ratio metabolic profiling and compared to prior analyses performed on 3D engineered adipose tissue in static culture. Traditional assessments with H&E staining were used to qualitatively measure extracellular matrix generation and cell density with respect to location within the tissue. The distribution of cells within the tissue and average cellular redox ratios were different between static and perfusion cultures, while the trends of decreased redox ratio and increased cellular proliferation with time in both static and perfusion cultures were similar. These results establish a basis for noninvasive optical tracking of tissue structure and function in vitro, which can be applied to future studies to assess tissue development or drug toxicity screening and disease progression.
Diffusing-wave polarimetry for tissue diagnostics
NASA Astrophysics Data System (ADS)
Macdonald, Callum; Doronin, Alexander; Peña, Adrian F.; Eccles, Michael; Meglinski, Igor
2014-03-01
We exploit the directional awareness of circularly and/or elliptically polarized light propagating within media which exhibit high numbers of scattering events. By tracking the Stokes vector of the detected light on the Poincaŕe sphere, we demonstrate its applicability for characterization of anisotropy of scattering. A phenomenological model is shown to have an excellent agreement with the experimental data and with the results obtained by the polarization tracking Monte Carlo model, developed in house. By analogy to diffusing-wave spectroscopy we call this approach diffusing-wave polarimetry, and illustrate its utility in probing cancerous and non-cancerous tissue samplesin vitro for diagnostic purposes.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-01
... Create-Bio Engineering Co. Ltd. Ningbo Generic Chemical Co. Qingdao Samin Chemical Co., Ltd. Paras... CHINA: Certain Tissue Paper 3/1/12-2/28/13 Products,\\8\\ A-570-894 AR Printing & Packaging (India) Pvt... does not qualify for a separate rate, all other exporters of Tissue Paper Products from the PRC who...
Liao, Naishun; Wu, Ming; Pan, Fan; Lin, Jiumao; Li, Zuanfang; Zhang, Da; Wang, Yingchao; Zheng, Youshi; Peng, Jun; Liu, Xiaolong; Liu, Jingfeng
2016-01-01
Tracking and monitoring of cells in vivo after transplantation can provide crucial information for stem cell therapy. Magnetic resonance imaging (MRI) combined with contrast agents is believed to be an effective and non-invasive technique for cell tracking in living bodies. However, commercial superparamagnetic iron oxide nanoparticles (SPIONs) applied to label cells suffer from shortages such as potential toxicity, low labeling efficiency, and low contrast enhancing. Herein, the adipose tissue-derived stem cells (ADSCs) were efficiently labeled with SPIONs coated with poly (dopamine) (SPIONs cluster@PDA), without affecting their viability, proliferation, apoptosis, surface marker expression, as well as their self-renew ability and multi-differentiation potential. The labeled cells transplanted into the mice through tail intravenous injection exhibited a negative enhancement of the MRI signal in the damaged liver-induced by carbon tetrachloride, and subsequently these homed ADSCs with SPIONs cluster@PDA labeling exhibited excellent repair effects to the damaged liver. Moreover, the enhanced target-homing to tissue of interest and repair effects of SPIONs cluster@PDA-labeled ADSCs could be achieved by use of external magnetic field in the excisional skin wound mice model. Therefore, we provide a facile, safe, noninvasive and sensitive method for external magnetic field targeted delivery and MRI based tracking of transplanted cells in vivo. PMID:26728448
SU-E-J-112: The Impact of Cine EPID Image Acquisition Frame Rate On Markerless Soft-Tissue Tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, S; Rottmann, J; Berbeco, R
2014-06-01
Purpose: Although reduction of the cine EPID acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor auto-tracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87Hz on an AS1000 portal imager. Low frame rate images were obtained by continuous frame averaging. A previously validated tracking algorithm was employed for auto-tracking. The difference between the programmed and auto-tracked positions of a Las Vegas phantommore » moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at eleven field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise were correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the auto-tracking errors increased at frame rates lower than 4.29Hz. Above 4.29Hz, changes in errors were negligible with δ<1.60mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R=0.94) and patient studies (R=0.72). Moderate to poor correlation was found between image noise and tracking error with R -0.58 and -0.19 for both studies, respectively. Conclusion: An image acquisition frame rate of at least 4.29Hz is recommended for cine EPID tracking. Motion blurring in images with frame rates below 4.39Hz can substantially reduce the accuracy of auto-tracking. This work is supported in part by the Varian Medical Systems, Inc.« less
2015-10-01
with Cancer in Non-Neoplastic Prostate Tissue PRINCIPAL INVESTIGATOR: Farhad Kosari, Ph.D. CONTRACTING ORGANIZATION: Mayo Clinic Rochester, MN...E-Mail: kosari.farhad@mayo.edu 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Mayo Clinic Rochester, MN 55905-0002 8...with the Tissue Request Acquisition Group (TRAG) at the Mayo Clinic , a process was implemented for the collection of resected prostates from
A secure mobile crowdsensing (MCS) location tracker for elderly in smart city
NASA Astrophysics Data System (ADS)
Shien, Lau Khai; Singh, Manmeet Mahinderjit
2017-10-01
According to the UN's (United Nations) projection, Malaysia will achieve ageing population status by 2030. The challenge of the growing ageing population is health and social care services. As the population lives longer, the costs of institutional care rises and elderly who not able live independently in their own homes without caregivers. Moreover, it restricted their activity area, safety and freedom in their daily life. Hence, a tracking system is worthy for their caregivers to track their real-time location with efficient. Currently tracking and monitoring systems are unable to satisfy the needs of the community. Hence, Indoor-Outdoor Elderly Secure and Tracking care system (IOET) proposed to track and monitor elderly. This Mobile Crowdsensing type of system is using indoor and outdoor positioning system to locate elder which utilizes the RFID, NFC, biometric system and GPS aim to secure the safety of elderly within indoors and outdoors environment. A mobile application and web-based application to be designed for this system. This system able to real-time tracking by combining GPS and NFC for outdoor coverage where ideally in smart city. In indoor coverage, the system utilizes active RFID tracking elderly movement. The system will prompt caregiver wherever elderly movement or request by using the notification service which provided the real-time notify. Caregiver also can review the place that visited by elderly and trace back elderly movement.
LENMODEL: A forward model for calculating length distributions and fission-track ages in apatite
NASA Astrophysics Data System (ADS)
Crowley, Kevin D.
1993-05-01
The program LENMODEL is a forward model for annealing of fission tracks in apatite. It provides estimates of the track-length distribution, fission-track age, and areal track density for any user-supplied thermal history. The program approximates the thermal history, in which temperature is represented as a continuous function of time, by a series of isothermal steps of various durations. Equations describing the production of tracks as a function of time and annealing of tracks as a function of time and temperature are solved for each step. The step calculations are summed to obtain estimates for the entire thermal history. Computational efficiency is maximized by performing the step calculations backwards in model time. The program incorporates an intuitive and easy-to-use graphical interface. Thermal history is input to the program using a mouse. Model options are specified by selecting context-sensitive commands from a bar menu. The program allows for considerable selection of equations and parameters used in the calculations. The program was written for PC-compatible computers running DOS TM 3.0 and above (and Windows TM 3.0 or above) with VGA or SVGA graphics and a Microsoft TM-compatible mouse. Single copies of a runtime version of the program are available from the author by written request as explained in the last section of this paper.
The PROTICdb database for 2-DE proteomics.
Langella, Olivier; Zivy, Michel; Joets, Johann
2007-01-01
PROTICdb is a web-based database mainly designed to store and analyze plant proteome data obtained by 2D polyacrylamide gel electrophoresis (2D PAGE) and mass spectrometry (MS). The goals of PROTICdb are (1) to store, track, and query information related to proteomic experiments, i.e., from tissue sampling to protein identification and quantitative measurements; and (2) to integrate information from the user's own expertise and other sources into a knowledge base, used to support data interpretation (e.g., for the determination of allelic variants or products of posttranslational modifications). Data insertion into the relational database of PROTICdb is achieved either by uploading outputs from Mélanie, PDQuest, IM2d, ImageMaster(tm) 2D Platinum v5.0, Progenesis, Sequest, MS-Fit, and Mascot software, or by filling in web forms (experimental design and methods). 2D PAGE-annotated maps can be displayed, queried, and compared through the GelBrowser. Quantitative data can be easily exported in a tabulated format for statistical analyses with any third-party software. PROTICdb is based on the Oracle or the PostgreSQLDataBase Management System (DBMS) and is freely available upon request at http://cms.moulon.inra.fr/content/view/14/44/.
Siminoff, Laura A; Wilson-Genderson, Maureen; Mosavel, Maghboeba; Barker, Laura; Trgina, Jennifer; Traino, Heather M; Nathan, Howard M; Hasz, Richard D; Walters, Gary
2018-01-01
Genomic research projects that collect tissues from deceased organ and tissue donors must obtain the authorization of family decision makers under difficult circumstances that may affect the authorization process. Using a quasi-experimental design, the Ethical, Legal, and Social Issues (ELSI) substudy of the Genotype-Tissue Expression (GTEx) project compared the recall and understanding of the donation authorization process of two groups: family members who had authorized donation of tissues to the GTEx project (the comparison group) and family members who had authorized organ and tissue donations in years previous, who subsequently participated in two different mock-authorization processes that mimicked the GTEx authorization process (the intervention groups). Participants in the comparison and intervention groups were matched on key demographic characteristics. We found that participants in the intervention groups who experienced a mock-authorization process demonstrated better recall of the tissue donation request than members of the comparison group. Our data indicate that the stress associated with the loss of a loved one limited the ability of family members to recall details about the GTEx project. However, we found a similar lack of knowledge in both the comparison and the intervention group participants, suggesting lack of knowledge may be due to the complexity and unfamiliarity of the information presented to them during the authorization process. We discuss these findings in the context of everyday clinical decision making in cognitively challenging conditions. Copyright 2018 The Journal of Clinical Ethics. All rights reserved.
Paperless Contract Folder’s (PCF) DoD 5015.2 Certification
2010-06-01
Draft Version Controls ...........................................................11 i. Electronic Routing of Purchase Request (Funding) Documents...of electronic records, version control , robust search and retrieval, and automated disposition that is compliant with legal requirements. As shown...h. Draft Version Controls Draft and versioning controls track the changes to the documents once they are saved. Draft numbers (0.1, 0.2, 0.3
Strategies for Automatic Track Initiation
1979-06-01
research and development; - Providing scientific and technical advice and assistancc to the North Atlantic Military Committee in the field of aerospace... research and development; - Rendering scientil and technical assistance, as requested, to other NATO bodies and to member nations in connection with rcý...tcchnical potential; - Recommending effective ways for the member nations to use their research and development capabilities for the common benefit of
GW170817: Tracking the X-ray light curve to study the origin of the emission
NASA Astrophysics Data System (ADS)
Wilkes, Belinda
2016-09-01
This proposal is a merger of several DDT requests to follow-up the NS-NS merger: GW170817 as it comes out of sunblock. We will include the proposing DDT teams as co-Is on this proposal. They will all have access to the data, but this proposal does not require that they work together.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-31
... Baseline Questionnaire for CLGs 250 .59 148 Annual Achievements Report for CLGs 900 2.20 1,980 State Inventory Maintenance 26,904 .46 12,376 State Review and Compliance Task Tracking 25,370 .17 4,313 State... regulations at 43 CFR part 12. This information collection also produces performance data that we use to...
The Kinect as an interventional tracking system
NASA Astrophysics Data System (ADS)
Wang, Xiang L.; Stolka, Philipp J.; Boctor, Emad; Hager, Gregory; Choti, Michael
2012-02-01
This work explores the suitability of low-cost sensors for "serious" medical applications, such as tracking of interventional tools in the OR, for simulation, and for education. Although such tracking - i.e. the acquisition of pose data e.g. for ultrasound probes, tissue manipulation tools, needles, but also tissue, bone etc. - is well established, it relies mostly on external devices such as optical or electromagnetic trackers, both of which mandate the use of special markers or sensors attached to each single entity whose pose is to be recorded, and also require their calibration to the tracked entity, i.e. the determination of the geometric relationship between the marker's and the object's intrinsic coordinate frames. The Microsoft Kinect sensor is a recently introduced device for full-body tracking in the gaming market, but it was quickly hacked - due to its wide range of tightly integrated sensors (RGB camera, IR depth and greyscale camera, microphones, accelerometers, and basic actuation) - and used beyond this area. As its field of view and its accuracy are within reasonable usability limits, we describe a medical needle-tracking system for interventional applications based on the Kinect sensor, standard biopsy needles, and no necessary attachments, thus saving both cost and time. Its twin cameras are used as a stereo pair to detect needle-shaped objects, reconstruct their pose in four degrees of freedom, and provide information about the most likely candidate.
Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju
2014-03-21
A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated.
The new millennium program: Fast-track procurements
NASA Astrophysics Data System (ADS)
Metzger, Robert M.
1996-11-01
The National Aeronautics and Space Administration's (NASA's) New Millennium Program (NMP) has embarked on a technology flight-validation demonstration program to enable the kinds of missions that NASA envisions for the 21st century. Embedded in this program is the concept of rapid mission development supported by a fast-track procurement process. This process begins with the decision to initiate a procurement very early in the program along with the formation of a technical acquisition team. A close working relationship among the team members is essential to avoiding delays and developing a clear acquisition plan. The request for proposal (RFP) that is subsequently issued seeks a company with proven capabilities, so that the time allotted for responses from proposers and the length of proposals they submit can be shortened. The fast-track procurement process has been demonstrated during selection of NMP's industrial partners and has been proven to work.
Track-structure simulations for charged particles.
Dingfelder, Michael
2012-11-01
Monte Carlo track-structure simulations provide a detailed and accurate picture of radiation transport of charged particles through condensed matter of biological interest. Liquid water serves as a surrogate for soft tissue and is used in most Monte Carlo track-structure codes. Basic theories of radiation transport and track-structure simulations are discussed and differences compared to condensed history codes highlighted. Interaction cross sections for electrons, protons, alpha particles, and light and heavy ions are required input data for track-structure simulations. Different calculation methods, including the plane-wave Born approximation, the dielectric theory, and semi-empirical approaches are presented using liquid water as a target. Low-energy electron transport and light ion transport are discussed as areas of special interest.
Imaging free zinc levels in vivo - what can be learned?
De Leon-Rodriguez, Luis; Lubag, Angelo Josue M; Sherry, A Dean
2012-12-01
Our ever-expanding knowledge about the role of zinc in biology includes its role in redox modulation, immune response, neurotransmission, reproduction, diabetes, cancer, and Alzheimers disease is galvanizing interest in detecting and monitoring the various forms of Zn(II) in biological systems. This paper reviews reported strategies for detecting and tracking of labile or "free" unchelated Zn(II) in tissues. While different bound structural forms of Zn(II) have been identified and studied in vitro by multiple techniques, very few molecular imaging methods have successfully tracked the ion in vivo. A number of MRI and optical strategies have now been reported for detection of free Zn(II) in cells and tissues but only a few have been applied successfully in vivo. A recent report of a MRI sensor for in vivo tracking of Zn(II) released from pancreatic β-cells during insulin secretion exemplifies the promise of rational design of new Zn(II) sensors for tracking this biologically important ion in vivo. Such studies promise to provide new insights into zinc trafficking in vivo and the critical role of this ion in many human diseases.
Langdon, Jonathan H; Elegbe, Etana; McAleavey, Stephen A
2015-01-01
Single Tracking Location (STL) Shear wave Elasticity Imaging (SWEI) is a method for detecting elastic differences between tissues. It has the advantage of intrinsic speckle bias suppression compared to Multiple Tracking Location (MTL) variants of SWEI. However, the assumption of a linear model leads to an overestimation of the shear modulus in viscoelastic media. A new reconstruction technique denoted Single Tracking Location Viscosity Estimation (STL-VE) is introduced to correct for this overestimation. This technique utilizes the same raw data generated in STL-SWEI imaging. Here, the STL-VE technique is developed by way of a Maximum Likelihood Estimation (MLE) for general viscoelastic materials. The method is then implemented for the particular case of the Kelvin-Voigt Model. Using simulation data, the STL-VE technique is demonstrated and the performance of the estimator is characterized. Finally, the STL-VE method is used to estimate the viscoelastic parameters of ex-vivo bovine liver. We find good agreement between the STL-VE results and the simulation parameters as well as between the liver shear wave data and the modeled data fit. PMID:26168170
Oxygen Nanobubble Tracking by Light Scattering in Single Cells and Tissues.
Bhandari, Pushpak; Wang, Xiaolei; Irudayaraj, Joseph
2017-03-28
Oxygen nanobubbles (ONBs) have significant potential in targeted imaging and treatment in cancer diagnosis and therapy. Precise localization and tracking of single ONBs is demonstrated based on hyperspectral dark-field microscope (HSDFM) to image and track single oxygen nanobubbles in single cells. ONBs were proposed as promising contrast-generating imaging agents due to their strong light scattering generated from nonuniformity of refractive index at the interface. With this powerful platform, we have revealed the trajectories and quantities of ONBs in cells, and demonstrated the relation between the size and diffusion coefficient. We have also evaluated the presence of ONBs in the nucleus with respect to an increase in incubation time and have quantified the uptake in single cells in ex vivo tumor tissues. Our results demonstrate that HSDFM can be a versatile platform to detect and measure cellulosic nanoparticles at the single-cell level and to assess the dynamics and trajectories of this delivery system.
Lyon, Jennifer A; Garcia-Milian, Rolando; Norton, Hannah F; Tennant, Michele R
2014-01-01
Expert-mediated literature searching, a keystone service in biomedical librarianship, would benefit significantly from regular methodical review. This article describes the novel use of Research Electronic Data Capture (REDCap) software to create a database of literature searches conducted at a large academic health sciences library. An archive of paper search requests was entered into REDCap, and librarians now prospectively enter records for current searches. Having search data readily available allows librarians to reuse search strategies and track their workload. In aggregate, this data can help guide practice and determine priorities by identifying users' needs, tracking librarian effort, and focusing librarians' continuing education.
Non-invasive pH determination adjacent to degradable biomaterials in vivo.
Bartsch, Ivonne; Willbold, Elmar; Rosenhahn, Bodo; Witte, Frank
2014-01-01
An appropriate pH level is an important prerequisite for the physiologal functioning of cells and tissues. Changes in the extracellular pH often lead to specific cellular reactions and an altered metabolism of cells and tissues influences the extracellular pH range. Thus a method to monitor the extracellular pH is a valuable tool to track specific tissue reactions. In this article we describe a method for the determination of the pH range adjacent to degradable biomaterials using wireless in vivo imaging. Using hairless but immunocompetent mice the fluorophor 5-(6)-carboxy SNARF-1 and the in vivo fluorescence and multispectral acquisition and analysis system Maestro it is possible to track shifts in pH in small living animals over a longer period of time. This method is especially suitable for studies which focus on the interaction of degrading biomaterials with their adjacent tissues. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Ma, Chi; Varghese, Tomy
2012-04-01
Accurate cardiac deformation analysis for cardiac displacement and strain imaging over time requires Lagrangian description of deformation of myocardial tissue structures. Failure to couple the estimated displacement and strain information with the correct myocardial tissue structures will lead to erroneous result in the displacement and strain distribution over time. Lagrangian based tracking in this paper divides the tissue structure into a fixed number of pixels whose deformation is tracked over the cardiac cycle. An algorithm that utilizes a polar-grid generated between the estimated endocardial and epicardial contours for cardiac short axis images is proposed to ensure Lagrangian description of the pixels. Displacement estimates from consecutive radiofrequency frames were then mapped onto the polar grid to obtain a distribution of the actual displacement that is mapped to the polar grid over time. A finite element based canine heart model coupled with an ultrasound simulation program was used to verify this approach. Segmental analysis of the accumulated displacement and strain over a cardiac cycle demonstrate excellent agreement between the ideal result obtained directly from the finite element model and our Lagrangian approach to strain estimation. Traditional Eulerian based estimation results, on the other hand, show significant deviation from the ideal result. An in vivo comparison of the displacement and strain estimated using parasternal short axis views is also presented. Lagrangian displacement tracking using a polar grid provides accurate tracking of myocardial deformation demonstrated using both finite element and in vivo radiofrequency data acquired on a volunteer. In addition to the cardiac application, this approach can also be utilized for transverse scans of arteries, where a polar grid can be generated between the contours delineating the outer and inner wall of the vessels from the blood flowing though the vessel.
Aghayee, Samira; Winkowski, Daniel E; Bowen, Zachary; Marshall, Erin E; Harrington, Matt J; Kanold, Patrick O; Losert, Wolfgang
2017-01-01
The application of 2-photon laser scanning microscopy (TPLSM) techniques to measure the dynamics of cellular calcium signals in populations of neurons is an extremely powerful technique for characterizing neural activity within the central nervous system. The use of TPLSM on awake and behaving subjects promises new insights into how neural circuit elements cooperatively interact to form sensory perceptions and generate behavior. A major challenge in imaging such preparations is unavoidable animal and tissue movement, which leads to shifts in the imaging location (jitter). The presence of image motion can lead to artifacts, especially since quantification of TPLSM images involves analysis of fluctuations in fluorescence intensities for each neuron, determined from small regions of interest (ROIs). Here, we validate a new motion correction approach to compensate for motion of TPLSM images in the superficial layers of auditory cortex of awake mice. We use a nominally uniform fluorescent signal as a secondary signal to complement the dynamic signals from genetically encoded calcium indicators. We tested motion correction for single plane time lapse imaging as well as multiplane (i.e., volume) time lapse imaging of cortical tissue. Our procedure of motion correction relies on locating the brightest neurons and tracking their positions over time using established techniques of particle finding and tracking. We show that our tracking based approach provides subpixel resolution without compromising speed. Unlike most established methods, our algorithm also captures deformations of the field of view and thus can compensate e.g., for rotations. Object tracking based motion correction thus offers an alternative approach for motion correction, one that is well suited for real time spike inference analysis and feedback control, and for correcting for tissue distortions.
Aghayee, Samira; Winkowski, Daniel E.; Bowen, Zachary; Marshall, Erin E.; Harrington, Matt J.; Kanold, Patrick O.; Losert, Wolfgang
2017-01-01
The application of 2-photon laser scanning microscopy (TPLSM) techniques to measure the dynamics of cellular calcium signals in populations of neurons is an extremely powerful technique for characterizing neural activity within the central nervous system. The use of TPLSM on awake and behaving subjects promises new insights into how neural circuit elements cooperatively interact to form sensory perceptions and generate behavior. A major challenge in imaging such preparations is unavoidable animal and tissue movement, which leads to shifts in the imaging location (jitter). The presence of image motion can lead to artifacts, especially since quantification of TPLSM images involves analysis of fluctuations in fluorescence intensities for each neuron, determined from small regions of interest (ROIs). Here, we validate a new motion correction approach to compensate for motion of TPLSM images in the superficial layers of auditory cortex of awake mice. We use a nominally uniform fluorescent signal as a secondary signal to complement the dynamic signals from genetically encoded calcium indicators. We tested motion correction for single plane time lapse imaging as well as multiplane (i.e., volume) time lapse imaging of cortical tissue. Our procedure of motion correction relies on locating the brightest neurons and tracking their positions over time using established techniques of particle finding and tracking. We show that our tracking based approach provides subpixel resolution without compromising speed. Unlike most established methods, our algorithm also captures deformations of the field of view and thus can compensate e.g., for rotations. Object tracking based motion correction thus offers an alternative approach for motion correction, one that is well suited for real time spike inference analysis and feedback control, and for correcting for tissue distortions. PMID:28860973
Fernández-de-Manúel, Laura; Díaz-Díaz, Covadonga; Jiménez-Carretero, Daniel; Torres, Miguel; Montoya, María C
2017-05-01
Embryonic stem cells (ESCs) can be established as permanent cell lines, and their potential to differentiate into adult tissues has led to widespread use for studying the mechanisms and dynamics of stem cell differentiation and exploring strategies for tissue repair. Imaging live ESCs during development is now feasible due to advances in optical imaging and engineering of genetically encoded fluorescent reporters; however, a major limitation is the low spatio-temporal resolution of long-term 3-D imaging required for generational and neighboring reconstructions. Here, we present the ESC-Track (ESC-T) workflow, which includes an automated cell and nuclear segmentation and tracking tool for 4-D (3-D + time) confocal image data sets as well as a manual editing tool for visual inspection and error correction. ESC-T automatically identifies cell divisions and membrane contacts for lineage tree and neighborhood reconstruction and computes quantitative features from individual cell entities, enabling analysis of fluorescence signal dynamics and tracking of cell morphology and motion. We use ESC-T to examine Myc intensity fluctuations in the context of mouse ESC (mESC) lineage and neighborhood relationships. ESC-T is a powerful tool for evaluation of the genealogical and microenvironmental cues that maintain ESC fitness.
Conformal needle-based ultrasound ablation using EM-tracked conebeam CT image guidance
NASA Astrophysics Data System (ADS)
Burdette, E. Clif; Banovac, Filip; Diederich, Chris J.; Cheng, Patrick; Wilson, Emmanuel; Cleary, Kevin R.
2011-03-01
Numerous studies have demonstrated the efficacy of interstitial ablative approaches for the treatment of renal and hepatic tumors. Despite these promising results, current systems remain highly dependent on operator skill, and cannot treat many tumors because there is little control of the size and shape of the zone of necrosis, and no control over ablator trajectory within tissue once insertion has taken place. Additionally, tissue deformation and target motion make it extremely difficult to accurately place the ablator device into the target. Irregularly shaped target volumes typically require multiple insertions and several sequential thermal ablation procedures. This study demonstrated feasibility of spatially tracked image-guided conformal ultrasound (US) ablation for percutaneous directional ablation of diseased tissue. Tissue was prepared by suturing the liver within a pig belly and 1mm BBs placed to serve as needle targets. The image guided system used integrated electromagnetic tracking and cone-beam CT (CBCT) with conformable needlebased high-intensity US ablation in the interventional suite. Tomographic images from cone beam CT were transferred electronically to the image-guided tracking system (IGSTK). Paired-point registration was used to register the target specimen to CT images and enable navigation. Path planning is done by selecting the target BB on the GUI of the realtime tracking system and determining skin entry location until an optimal path is selected. Power was applied to create the desired ablation extent within 7-10 minutes at a thermal dose (>300eqm43). The system was successfully used to place the US ablator in planned target locations within ex-vivo kidney and liver through percutaneous access. Targeting accuracy was 3-4 mm. Sectioned specimens demonstrated uniform ablation within the planned target zone. Subsequent experiments were conducted for multiple ablator positions based upon treatment planning simulations. Ablation zones in liver were 73cc, 84cc, and 140cc for 3, 4, and 5 placements, respectively. These experiments demonstrate the feasibility of combining real-time spatially tracked image guidance with directional interstitial ultrasound ablation. Interstitial ultrasound ablation delivered on multiple needles permit the size and shape of the ablation zone to be "sculpted" by modifying the angle and intensity of the active US elements in the array. This paper summarizes the design and development of the first system incorporating thermal treatment planning and integration of a novel interstitial acoustic ablation device with integrated 3D electromagnetic tracking and guidance strategy.
Tracking stem cells in tissue-engineered organs using magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Hachani, Roxanne; Lowdell, Mark; Birchall, Martin; Thanh, NguyêN. Thi Kim
2013-11-01
The use of human stem cells (SCs) in tissue engineering holds promise in revolutionising the treatment of numerous diseases. There is a pressing need to comprehend the distribution, movement and role of SCs once implanted onto scaffolds. Nanotechnology has provided a platform to investigate this through the development of inorganic magnetic nanoparticles (MNPs). MNPs can be used to label and track SCs by magnetic resonance imaging (MRI) since this clinically available imaging modality has high spatial resolution. In this review, we highlight recent applications of iron oxide and gadolinium based MNPs in SC labelling and MRI; and offer novel considerations for their future development.
[U.S. renewable fuel standard implementation mechanism and market tracking].
Kang, Liping; Earley, Robert; An, Feng; Zhang, Yu
2013-03-01
U.S. Renewable Fuel Standard (RFS) is a mandatory policy for promoting the utilization of biofuels in road transpiration sector in order to reduce the country's dependency on foreign oil and greenhouse gas emissions. U.S. Environmental Protection Agency (EPA) defines the proportion of renewable fuels according to RFS annual target, and requests obligated parties such like fossil fuel refiner, blenders and importer in the U.S. to complete Renewable Volume Obligation (RVO) every year. Obligated parties prove they have achieved their RVO through a renewable fuels certification system, which generates Renewable Identification Numbers (RINs) for every gallon of qualified renewable fuels produced or imported into U.S., RINs is a key for tracking renewable fuel consumption, which in turn is a key for implementing the RFS in the U.S., separated RINs can be freely traded in market and obligated parties could fulfill their RVO through buying RINs from other stakeholders. This briefing paper highlights RFS policy implementing mechanism and marketing tracking, mainly describes importance of RINs, and the method for generating and tracking RINs by both government and fuels industry participants.
Design of a new tracking device for on-line beam range monitor in carbon therapy.
Traini, Giacomo; Battistoni, Giuseppe; Bollella, Angela; Collamati, Francesco; De Lucia, Erika; Faccini, Riccardo; Ferroni, Fernando; Frallicciardi, Paola Maria; Mancini-Terracciano, Carlo; Marafini, Michela; Mattei, Ilaria; Miraglia, Federico; Muraro, Silvia; Paramatti, Riccardo; Piersanti, Luca; Pinci, Davide; Rucinski, Antoni; Russomando, Andrea; Sarti, Alessio; Sciubba, Adalberto; Senzacqua, Martina; Solfaroli-Camillocci, Elena; Toppi, Marco; Voena, Cecilia; Patera, Vincenzo
2017-02-01
Charged particle therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbon ions. A critical issue is the monitoring of the beam range so to check the correct dose deposition to the tumor and surrounding tissues. The design of a new tracking device for beam range real-time monitoring in pencil beam carbon ion therapy is presented. The proposed device tracks secondary charged particles produced by beam interactions in the patient tissue and exploits the correlation of the charged particle emission profile with the spatial dose deposition and the Bragg peak position. The detector, currently under construction, uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a pixelated Lutetium Fine Silicate (LFS) crystal calorimeter. An algorithm to account and correct for emission profile distortion due to charged secondaries absorption inside the patient tissue is also proposed. Finally detector reconstruction efficiency for charged particle emission profile is evaluated using a Monte Carlo simulation considering a quasi-realistic case of a non-homogenous phantom. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Chamma, Emilie; Qiu, Jimmy; Lindvere-Teene, Liis; Blackmore, Kristina M.; Majeed, Safa; Weersink, Robert; Dickie, Colleen I.; Griffin, Anthony M.; Wunder, Jay S.; Ferguson, Peter C.; DaCosta, Ralph S.
2015-07-01
Standard clinical management of extremity soft tissue sarcomas includes surgery with radiation therapy. Wound complications (WCs) arising from treatment may occur due to bacterial infection and tissue breakdown. The ability to detect changes in these parameters during treatment may lead to earlier interventions that mitigate WCs. We describe the use of a new system composed of an autofluorescence imaging device and an optical three-dimensional tracking system to detect and coregister the presence of bacteria with radiation doses. The imaging device visualized erythema using white light and detected bacterial autofluorescence using 405-nm excitation light. Its position was tracked relative to the patient using IR reflective spheres and registration to the computed tomography coordinates. Image coregistration software was developed to spatially overlay radiation treatment plans and dose distributions on the white light and autofluorescence images of the surgical site. We describe the technology, its use in the operating room, and standard operating procedures, as well as demonstrate technical feasibility and safety intraoperatively. This new clinical tool may help identify patients at greater risk of developing WCs and investigate correlations between radiation dose, skin response, and changes in bacterial load as biomarkers associated with WCs.
75 FR 63145 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-14
... information on other life history and reference level data, including marine mammal tissue analyses, [email protected] . Dated: October 7, 2010. Gwellnar Banks, Management Analyst, Office of the Chief...
Harris, Paul A; Kirby, Jacqueline; Swafford, Jonathan A; Edwards, Terri L; Zhang, Minhua; Yarbrough, Tonya R; Lane, Lynda D; Helmer, Tara; Bernard, Gordon R; Pulley, Jill M
2015-08-01
Peer-reviewed publications are one measure of scientific productivity. From a project, program, or institutional perspective, publication tracking provides the quantitative data necessary to guide the prudent stewardship of federal, foundation, and institutional investments by identifying the scientific return for the types of support provided. In this article, the authors describe the Vanderbilt Institute for Clinical and Translational Research's (VICTR's) development and implementation of a semiautomated process through which publications are automatically detected in PubMed and adjudicated using a "just-in-time" workflow by a known pool of researchers (from Vanderbilt University School of Medicine and Meharry Medical College) who receive support from Vanderbilt's Clinical and Translational Science Award. Since implementation, the authors have (1) seen a marked increase in the number of publications citing VICTR support, (2) captured at a more granular level the relationship between specific resources/services and scientific output, (3) increased awareness of VICTR's scientific portfolio, and (4) increased efficiency in complying with annual National Institutes of Health progress reports. They present the methodological framework and workflow, measures of impact for the first 30 months, and a set of practical lessons learned to inform others considering a systems-based approach for resource and publication tracking. They learned that contacting multiple authors from a single publication can increase the accuracy of the resource attribution process in the case of multidisciplinary scientific projects. They also found that combining positive (e.g., congratulatory e-mails) and negative (e.g., not allowing future resource requests until adjudication is complete) triggers can increase compliance with publication attribution requests.
The AIDS and Cancer Specimen Resource: Role in HIV/AIDS scientific discovery
Ayers, Leona W; Silver, Sylvia; McGrath, Michael S; Orenstein, Jan M
2007-01-01
The AIDS Cancer and Specimen Resource (ACSR) supports scientific discovery in the area of HIV/AIDS-associated malignancies. The ACSR was established as a cooperative agreement between the NCI (Office of the Director, Division of Cancer Treatment and Diagnosis) and regional consortia, University of California, San Francisco (West Coast), George Washington University (East Coast) and Ohio State University (Mid-Region) to collect, preserve and disperse HIV-related tissues and biologic fluids and controls along with clinical data to qualified investigators. The available biological samples with clinical data and the application process are described on the ACSR web site. The ACSR tissue bank has more than 100,000 human HIV positive specimens that represent different processing (43), specimen (15), and anatomical site (50) types. The ACSR provides special biospecimen collections and prepares speciality items, e.g., tissue microarrays (TMA), DNA libraries. Requests have been greatest for Kaposi's sarcoma (32%) and non-Hodgkin's lymphoma (26%). Dispersed requests include 83% tissue (frozen and paraffin embedded), 18% plasma/serum and 9% other. ACSR also provides tissue microarrays of, e.g., Kaposi's sarcoma and non-Hodgkin's lymphoma, for biomarker assays and has developed collaborations with other groups that provide access to additional AIDS-related malignancy specimens. ACSR members and associates have completed 63 podium and poster presentations. Investigators have submitted 125 letters of intent requests. Discoveries using ACSR have been reported in 61 scientific publications in notable journals with an average impact factor of 7. The ACSR promotes the scientific exploration of the relationship between HIV/AIDS and malignancy by participation at national and international scientific meetings, contact with investigators who have productive research in this area and identifying, collecting, preserving, enhancing, and dispersing HIV/AIDS-related malignancy specimens to funded, approved researchers at no fee. Scientific discovery has been advanced by this unique biorepository. Investigators are encouraged to browse the ACSR Internet site for materials to enhance their own scientific initiatives. PMID:17335575
[To improve the quality of requisitions for radiologic examinations].
Roussel, P; Lelièvre, N
2002-05-01
This article presents the different steps implemented in order to improve the quality of requisitions for radiologic examinations in a hospital. and methods. The radiology requests sent from clinical units are periodically analyzed using criteria about tracking, prescription and security required for a good examination. Results are discussed with the clinical units in order to achieve improvements. The periodical analysis of nonconformities shows a gradual improvement of practices. This action contributes to the realization of a single document for every request of examination or analysis in the hospital. The described action is in the context of French regulations, first about the practice of radiology, second about the obligation of quality improvement that health care facilities now have to implement for their accreditation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... December 31, 2015. In the case of future cessation of local service, the expectation may be documented by... anticipate future requests for service not in keeping with prior service patterns.(See § 236.1005(b)(3)). (2... procedures and using the same methodology as required for safety and security route analysis under 49 CFR 172...
ERIC Educational Resources Information Center
General Accounting Office, Washington, DC.
The U.S. Congress asked the Government Accounting Office (GAO) to determine the following: (1) to what extent states were spending their Workforce Investment Act (WIA) funds and whether the Department of Labor's (Labor's) data accurately reflected available funds; (2) what Labor did to assess how states were managing their WIA spending; and (3)…
2018-04-11
iss055e018653 (April 11, 2018) --- NASA astronaut Scott Tingle performs research operations with the Microgravity Sciences Glovebox inside the U.S. Destiny laboratory module. Tingle was working on the Metabolic Tracking experiment that looks at a particular type of medicine and how it interacts with human tissue cultures. Results could improve therapies in space and lead to better, cheaper drugs on Earth.
2018-04-13
iss055e035338 (April 13, 2018) --- NASA astronaut Scott Tingle performs research operations with the Microgravity Sciences Glovebox inside the U.S. Destiny laboratory module. Tingle was working on the Metabolic Tracking experiment that looks at a particular type of medicine and how it interacts with human tissue cultures. Results could improve therapies in space and lead to better, cheaper drugs on Earth.
Extending neutron autoradiography technique for boron concentration measurements in hard tissues.
Provenzano, Lucas; Olivera, María Silvina; Saint Martin, Gisela; Rodríguez, Luis Miguel; Fregenal, Daniel; Thorp, Silvia I; Pozzi, Emiliano C C; Curotto, Paula; Postuma, Ian; Altieri, Saverio; González, Sara J; Bortolussi, Silva; Portu, Agustina
2018-07-01
The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10 B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 10 12 cm -2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10 B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis. Copyright © 2018 Elsevier Ltd. All rights reserved.
Lee, Annisa Lai
2009-06-01
This study tracks the changes of the effects of 4 information sources for direct-to-consumer drug advertising on patients' requests for prescription drugs from physicians since the inception of the "Guidance for Industry about Consumer-directed Broadcast Advertisements." The Guidance advises pharmaceuticals to use four information sources for consumers to seek further information to supplement broadcast drug advertisements: small-print information, the Internet, a toll-free number, and health-care providers (nurses, doctors, and pharmacists). Logistic models were created by using survey data collected by the Food and Drug Administration in 1999 and 2002. Results show that throughout the years, health-care providers remain the most used and strongest means associated with patients' direct requests for nonspecific and specific prescription drugs from doctors. The small-print information source gains power and changes from an indirect means associated with patients' discussing drugs with health-care providers to a direct means associated with patients' asking about nonspecific and specific drugs from their doctors. The Internet is not directly related to drug requests, but the effect of its association with patients seeking information from health-care providers grew 11-fold over the course of the study. The toll-free number lost its power altogether for both direct request for a prescription drug and further discussion with health-care providers. Patient demographics will be considered for specific policy implications.
78 FR 20352 - Endangered and Threatened Species Permit Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-04
... Applicant: Burns and McDonnell Engineering, Kansas City, Missouri. Applicant requests an amendment to a..., identify, and release using mist nets and harp traps; collect tissue samples using wing punches, hair...
Gordon, S; Holdsworth, R; Müller, C; Tiedemann, K
2007-04-01
Good communication between the bone marrow registries, the donor centres, tissue typing laboratories and clinical units is paramount to ensure timely identification, testing and selection of donors for unrelated bone marrow transplants. This panel session focussed on how to improve communication so that there was a clear understanding of prioritization of requests from clinicians, typing strategies in the laboratories and requests for donors to the registries. This paper outlined some of the strategies discussed in this session.
Lee, Kenneth; Boimer, Corey; Hershenfeld, Samantha; Sharpen, Linda; Slomovic, Allan R
2011-10-01
To assess whether provinces with Routine Notification and Request (RNR) legislation have sustained increases in corneal tissue supply and decreases in wait times for corneal transplantation surgery. Cross-sectional survey of Canadian corneal transplant (CT) surgeons and eye banks. Canadian CT surgeons and representatives from the 10 Canadian eye banks. Voluntary and anonymous surveys were distributed between July and October 2009. Eligible CT surgeons were defined as ophthalmologists who practice in Canada; currently perform Penetrating keratoplasty (PKP), Deep anterior lamellar keratoplasty (DALK), Deep lamellar endothelial keratoplasty (DLEK), Descemet stripping endothelial keratoplasty (DSEK), or Descemet membrane endothelial keratoplasty (DMEK); and have obtained tissues from a Canadian eye bank. From 2006 to 2009, for provinces with RNR legislation and where data are available, mean wait times from date of diagnosis to date of CT surgery have increased: in Ontario, from 31 ± 34 weeks to 36 ± 27 weeks; in British Columbia, from 39 ± 20 weeks to 42 ± 35 weeks; in Manitoba, from 32 ± 23 weeks to 49 ± 36 weeks. In addition, the amount of corneal tissue in RNR provinces suitable for transplant, with the exception of British Columbia, has declined between 2006 and 2008: in Ontario, 1186 tissues to 999 tissues (16% decline); in Manitoba, 92 tissues to 83 tissues (10% decline); in New Brunswick, 129 tissues to 98 tissues (24% decline). Although initially effective, RNR legislation has not sustained an increase in corneal tissue availability nor has it shortened wait times in most provinces. Incorporation of community hospitals into the RNR catchment, improved enforcement, and continued education of hospital staff regarding the RNR process may be effective in making this legislation more sustainable in the long term. Copyright © 2011 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Gaze-contingent soft tissue deformation tracking for minimally invasive robotic surgery.
Mylonas, George P; Stoyanov, Danail; Deligianni, Fani; Darzi, Ara; Yang, Guang-Zhong
2005-01-01
The introduction of surgical robots in Minimally Invasive Surgery (MIS) has allowed enhanced manual dexterity through the use of microprocessor controlled mechanical wrists. Although fully autonomous robots are attractive, both ethical and legal barriers can prohibit their practical use in surgery. The purpose of this paper is to demonstrate that it is possible to use real-time binocular eye tracking for empowering robots with human vision by using knowledge acquired in situ. By utilizing the close relationship between the horizontal disparity and the depth perception varying with the viewing distance, it is possible to use ocular vergence for recovering 3D motion and deformation of the soft tissue during MIS procedures. Both phantom and in vivo experiments were carried out to assess the potential frequency limit of the system and its intrinsic depth recovery accuracy. The potential applications of the technique include motion stabilization and intra-operative planning in the presence of large tissue deformation.
Co:MgF2 laser ablation of tissue: effect of wavelength on ablation threshold and thermal damage.
Schomacker, K T; Domankevitz, Y; Flotte, T J; Deutsch, T F
1991-01-01
The wavelength dependence of the ablation threshold of a variety of tissues has been studied by using a tunable pulsed Co:MgF2 laser to determine how closely it tracks the optical absorption length of water. The Co:MgF2 laser was tuned between 1.81 and 2.14 microns, a wavelength region in which the absorption length varies by a decade. For soft tissues the ablation threshold tracks the optical absorption length; for bone there is little wavelength dependence, consistent with the low water content of bone. Thermal damage vs. wavelength was also studied for cornea and bone. Thermal damage to cornea has a weak wavelength dependence, while that to bone shows little wavelength dependence. Framing-camera pictures of the ablation of both cornea and liver show explosive removal of material, but differ as to the nature of the explosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ge, Y; Keall, P; Poulsen, P
Purpose: Multiple targets with large intrafraction independent motion are often involved in advanced prostate, lung, abdominal, and head and neck cancer radiotherapy. Current standard of care treats these with the originally planned fields, jeopardizing the treatment outcomes. A real-time multi-leaf collimator (MLC) tracking method has been developed to address this problem for the first time. This study evaluates the geometric uncertainty of the multi-target tracking method. Methods: Four treatment scenarios are simulated based on a prostate IMAT plan to treat a moving prostate target and static pelvic node target: 1) real-time multi-target MLC tracking; 2) real-time prostate-only MLC tracking; 3)more » correcting for prostate interfraction motion at setup only; and 4) no motion correction. The geometric uncertainty of the treatment is assessed by the sum of the erroneously underexposed target area and overexposed healthy tissue areas for each individual target. Two patient-measured prostate trajectories of average 2 and 5 mm motion magnitude are used for simulations. Results: Real-time multi-target tracking accumulates the least uncertainty overall. As expected, it covers the static nodes similarly well as no motion correction treatment and covers the moving prostate similarly well as the real-time prostate-only tracking. Multi-target tracking reduces >90% of uncertainty for the static nodal target compared to the real-time prostate-only tracking or interfraction motion correction. For prostate target, depending on the motion trajectory which affects the uncertainty due to leaf-fitting, multi-target tracking may or may not perform better than correcting for interfraction prostate motion by shifting patient at setup, but it reduces ∼50% of uncertainty compared to no motion correction. Conclusion: The developed real-time multi-target MLC tracking can adapt for the independently moving targets better than other available treatment adaptations. This will enable PTV margin reduction to minimize health tissue toxicity while remain tumor coverage when treating advanced disease with independently moving targets involved. The authors acknowledge funding support from the Australian NHMRC Australia Fellowship and NHMRC Project Grant No. APP1042375.« less
Jeong, Seol Young; Jo, Hyeong Gon; Kang, Soon Ju
2014-01-01
A tracking service like asset management is essential in a dynamic hospital environment consisting of numerous mobile assets (e.g., wheelchairs or infusion pumps) that are continuously relocated throughout a hospital. The tracking service is accomplished based on the key technologies of an indoor location-based service (LBS), such as locating and monitoring multiple mobile targets inside a building in real time. An indoor LBS such as a tracking service entails numerous resource lookups being requested concurrently and frequently from several locations, as well as a network infrastructure requiring support for high scalability in indoor environments. A traditional centralized architecture needs to maintain a geographic map of the entire building or complex in its central server, which can cause low scalability and traffic congestion. This paper presents a self-organizing and fully distributed indoor mobile asset management (MAM) platform, and proposes an architecture for multiple trackees (such as mobile assets) and trackers based on the proposed distributed platform in real time. In order to verify the suggested platform, scalability performance according to increases in the number of concurrent lookups was evaluated in a real test bed. Tracking latency and traffic load ratio in the proposed tracking architecture was also evaluated. PMID:24662407
TAGGING, TRACKING AND LOCATING WITHOUT GPS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cordaro, J.; Coleman, T.; Shull, D.
The Savannah River National Laboratory (SRNL) was requested to lead a Law Enforcement Working Group that was formed to collaborate on common operational needs. All agencies represented on the working group ranked their need to tag, track, and locate a witting or unwitting target as their highest priority. Specifically, they were looking for technologies more robust than Global Positioning Satellite (GPS), could communicate back to the owner, and worked where normal cell phone communications did not work or were unreliable. SRNL brought together multiple technologies in a demonstration that was held in in various Alaska venues, including metropolitan, wilderness, andmore » at-sea that met the working group's requirements. Using prototypical technologies from Boeing, On Ramp, and Fortress, SRNL was able to demonstrate the ability to track personnel and material in all scenarios including indoors, in heavily wooden areas, canyons, and in parking garages. In all cases GPS signals were too weak to measure. Bi-directional communication was achieved in areas that Wi-Fi, cell towers, or traditional radios would not perform. The results of the exercise will be presented. These technologies are considered ideal for tracking high value material such has nuclear material with a platform that allows seamless tracking anywhere in the world, indoors or outdoors.« less
NASA Astrophysics Data System (ADS)
Lee, Hannah J.; Choi, Gye Won; Alqathami, Mamdooh; Kadbi, Mo; Ibbott, Geoffrey
2017-05-01
Image-guided radiation therapy (IGRT) using computed tomography (CT), cone-beam CT, MV on-board imager (OBI), and kV OBI systems have allowed for more accurate patient positioning prior to each treatment fraction. While these imaging modalities provide excellent bony anatomy image quality, MRI surpasses them in soft tissue image contrast for better visualization and tracking of soft tissue tumors with no additional radiation dose to the patient. A pre-clinical integrated 1.5 T magnetic resonance imaging and 7 MV linear accelerator system (MR-linac) allows for real-time tracking of soft tissues and adaptive treatment planning prior to each treatment fraction. However, due to the presence of a strong magnetic field from the MR component, there is a three dimensional (3D) change in dose deposited by the secondary electrons. Especially at nonhomogeneous anatomical sites with tissues of very different densities, dose enhancements and reductions can occur due to the Lorentz force influencing the trajectories of secondary electrons. These dose changes at tissue interfaces are called the electron return effect or ERE. This study investigated the ERE using 3D dosimeters.
Jia, Rui; Monk, Paul; Murray, David; Noble, J Alison; Mellon, Stephen
2017-09-06
Optoelectronic motion capture systems are widely employed to measure the movement of human joints. However, there can be a significant discrepancy between the data obtained by a motion capture system (MCS) and the actual movement of underlying bony structures, which is attributed to soft tissue artefact. In this paper, a computer-aided tracking and motion analysis with ultrasound (CAT & MAUS) system with an augmented globally optimal registration algorithm is presented to dynamically track the underlying bony structure during movement. The augmented registration part of CAT & MAUS was validated with a high system accuracy of 80%. The Euclidean distance between the marker-based bony landmark and the bony landmark tracked by CAT & MAUS was calculated to quantify the measurement error of an MCS caused by soft tissue artefact during movement. The average Euclidean distance between the target bony landmark measured by each of the CAT & MAUS system and the MCS alone varied from 8.32mm to 16.87mm in gait. This indicates the discrepancy between the MCS measured bony landmark and the actual underlying bony landmark. Moreover, Procrustes analysis was applied to demonstrate that CAT & MAUS reduces the deformation of the body segment shape modeled by markers during motion. The augmented CAT & MAUS system shows its potential to dynamically detect and locate actual underlying bony landmarks, which reduces the MCS measurement error caused by soft tissue artefact during movement. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tsuda, Shuichi; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Sasaki, Shinichi
Lineal energy (y) distributions were measured for various types of charged particles such as protons and iron, with kinetic energies of up to 500 MeV/u, via the use of a wall-less tissue-equivalent proportional counter (TEPC). Radial dependencies of y distributions were also experimentally evaluated to investigate the track structures of protons, carbon, and iron beams. This paper reviews a series of measured data using the aforementioned TEPC as well as assesses the systematic verification of a microdosimetric calculation model of a y distribution incorporated into the particle and heavy ion transport code system (PHITS) and associated track structure models.
1989-08-01
Include in this plan the role of the Defense Technical Information Center (DTIC), the Defense Technology Security Administration ( DTSA ), and ODDR&E’s...DTIC = Defense Technical Information Center DTSA = Defense Technology Security Administration DUSD = Deputy Under Secretary of Defense Gloss. 2 DUSD...technologically sensitive requests. The Defense Technology Security Administi ation ( DTSA ) is developing a large system to track foreign military sales
NASA Hitchhiker Program Customer Payload Requirements (CPR)
NASA Technical Reports Server (NTRS)
Horan, Stephen
1998-01-01
The mission objective is to demonstrate each of the three types of technology intended for future small-satellite communications system design. Each experiment in the overall package is designed to exercise a different technology objective that may be found in the overall satellite communications and telemetry system design. The data communications through TORSS portion is designed to demonstrate that low-power communications systems with non-gimbaled antenna systems can transport significant quantities of data through TDRSS to the ground based on only transmitting through a TDRS when the experiment is near the TDRS subsatellite point. The remaining time. the payload communications system is not active. The demand access experiment is to demonstrate that the request for a demand access service can be transmitted through TDRS and received and decoded at the ground station. In this mode, the TDRS does not track the experiment but signal processing components at the White Sands Complex are used to detect and track the transmitted request. The laser communications experiment is designed to demonstrate passive transmission of telemetry data from the experiment. This mode uses a ground-based laser source to illuminate the experiment and modulate the beam with the data. Ground-based reception recovers the data from the reflected beam back to the ground station.
Mishra, Sushanta Kumar; Khushu, Subash; Singh, Ajay K; Gangenahalli, Gurudutta
2018-06-17
Stem cells transplantation has emerged as a promising alternative therapeutic due to its potency at injury site. The need to monitor and non-invasively track the infused stem cells is a significant challenge in the development of regenerative medicine. Thus, in vivo tracking to monitor infused stem cells is especially vital. In this manuscript, we have described an effective in vitro labelling method of MSCs, a serial in vivo tracking of implanted stem cells at traumatic brain injury (TBI) site through 7 T magnetic resonance imaging (MRI). Proper homing of infused MSCs was carried out at different time points using histological analysis and Prussian blue staining. Longitudinal in vivo tracking of infused MSCs were performed up to 21 days in different groups through MRI using relaxometry technique. Results demonstrated that MSCs incubated with iron oxide-poly-L-lysine complex (IO-PLL) at a ratio of 50:1.5 μg/ml and a time period of 6 h was optimised to increase labelling efficiency. T2*-weighted images and relaxation study demonstrated a significant signal loss and effective decrease in transverse relaxation time on day-3 at injury site after systemic transplantation, revealed maximum number of stem cells homing to the lesion area. MRI results further correlate with histological and Prussian blue staining in different time periods. Decrease in negative signal and increase in relaxation times were observed after day-14, may indicate damage tissue replacement with healthy tissue. MSCs tracking with synthesized negative contrast agent represent a great advantage during both in vitro and in vivo analysis. The proposed absolute bias correction based relaxometry analysis could be extrapolated for stem cell tracking and therapies in various neurodegenerative diseases.
Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking.
Fadnes, Solveig; Nyrnes, Siri Ann; Torp, Hans; Lovstakken, Lasse
2014-10-01
High-frame-rate ultrasound speckle tracking was used for quantification of peak velocity in shunt flows resulting from septal defects in congenital heart disease. In a duplex acquisition scheme implemented on a research scanner, unfocused transmit beams and full parallel receive beamforming were used to achieve a frame rate of 107 frames/s for full field-of-view flow images with high accuracy, while also ensuring high-quality focused B-mode tissue imaging. The setup was evaluated in vivo for neonates with atrial and ventricular septal defects. The shunt position was automatically tracked in B-mode images and further used in blood speckle tracking to obtain calibrated shunt flow velocities throughout the cardiac cycle. Validation toward color flow imaging and pulsed wave Doppler with manual angle correction indicated that blood speckle tracking could provide accurate estimates of shunt flow velocities. The approach was less biased by clutter filtering compared with color flow imaging and was able to provide velocity estimates beyond the Nyquist range. Possible placements of sample volumes (and angle corrections) for conventional Doppler resulted in a peak shunt velocity variations of 0.49-0.56 m/s for the ventricular septal defect of patient 1 and 0.38-0.58 m/s for the atrial septal defect of patient 2. In comparison, the peak velocities found from speckle tracking were 0.77 and 0.33 m/s for patients 1 and 2, respectively. Results indicated that complex intraventricular flow velocity patterns could be quantified using high-frame-rate speckle tracking of both blood and tissue movement. This could potentially help increase diagnostic accuracy and decrease inter-observer variability when measuring peak velocity in shunt flows. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fahimian, B.
2015-06-15
Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Low, D.
2015-06-15
Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berbeco, R.
2015-06-15
Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keall, P.
2015-06-15
Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less
Characterization of the Reproductive Toxicity of Depleted Uranium
2005-06-01
thymus, kidney, liver, skeletal muscle, uterus, ovaries, testes, bone marrow. Requested tissues were identified, embedded in paraffin and trimmed...located (all but 2-females), a cross section of the uterus was processed for evaluation. Each sample of skeletal muscle was bread-loafed in an attempt...correlation with the formation of soft tissue sarcomas . In contrast, none of these three animal’s implant sites showed evidence of a proliferative or
Motion compensation for in vivo subcellular optical microscopy.
Lucotte, B; Balaban, R S
2014-04-01
In this review, we focus on the impact of tissue motion on attempting to conduct subcellular resolution optical microscopy, in vivo. Our position is that tissue motion is one of the major barriers in conducting these studies along with light induced damage, optical probe loading as well as absorbing and scattering effects on the excitation point spread function and collection of emitted light. Recent developments in the speed of image acquisition have reached the limit, in most cases, where the signal from a subcellular voxel limits the speed and not the scanning rate of the microscope. Different schemes for compensating for tissue displacements due to rigid body and deformation are presented from tissue restriction, gating, adaptive gating and active tissue tracking. We argue that methods that minimally impact the natural physiological motion of the tissue are desirable because the major reason to perform in vivo studies is to evaluate normal physiological functions. Towards this goal, active tracking using the optical imaging data itself to monitor tissue displacement and either prospectively or retrospectively correct for the motion without affecting physiological processes is desirable. Critical for this development was the implementation of near real time image processing in conjunction with the control of the microscope imaging parameters. Clearly, the continuing development of methods of motion compensation as well as significant technological solutions to the other barriers to tissue subcellular optical imaging in vivo, including optical aberrations and overall signal-to-noise ratio, will make major contributions to the understanding of cell biology within the body.
Page, Michael J.; Lourenço, André L.; David, Tovo; LeBeau, Aaron M.; Cattaruzza, Fiore; Castro, Helena C.; VanBrocklin, Henry F.; Coughlin, Shaun R.; Craik, Charles S.
2015-01-01
Functional imaging of proteolytic activity is an emerging strategy to quantify disease and response to therapy at the molecular level. We present a new peptide-based imaging probe technology that advances these goals by exploiting enzymatic activity to deposit probes labelled with near-infrared (NIR) fluorophores or radioisotopes in cell membranes of disease-associated proteolysis. This strategy allows for non-invasive detection of protease activity in vivo and ex vivo by tracking deposited probes in tissues. We demonstrate non-invasive detection of thrombin generation in a murine model of pulmonary embolism using our protease-activated peptide probes in microscopic clots within the lungs with NIR fluorescence optical imaging and positron-emission tomography. Thrombin activity is imaged deep in tissue and tracked predominantly to platelets within the lumen of blood vessels. The modular design of our probes allows for facile investigation of other proteases, and their contributions to disease by tailoring the protease activation and cell-binding elements. PMID:26423607
NASA Technical Reports Server (NTRS)
Savin, Stephen C.
2005-01-01
The MER project includes two rovers working simultaneously on opposite sides of Mars each receiving commands only once a day. Creating this uplink is critical, since a failed uplink means a lost day and a waste of money. Examining the process of creating this uplink, I tracked the use of the system developed for requesting observations as well as the development, from stage to stage, in forming an activity plan. I found the system for requesting observations was commonly misused, if used at all. There are half a dozen reports to document the creation of the uplink plan and often there are discrepancies among them. Despite this, the uplink process worked very well and MER has been one of the most successful missions for NASA in recent memory. Still it is clear there is room for improvement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rottmann, J; Berbeco, R; Keall, P
Purpose: To maximize normal tissue sparing for treatments requiring motion encompassing margins. Motion mitigation techniques including DMLC or couch tracking can freeze tumor motion within the treatment aperture potentially allowing for smaller treatment margins and thus better sparing of normal tissue. To enable for a safe application of this concept in the clinic we propose adapting margins dynamically in real-time during radiotherapy delivery based on personalized tumor localization confidence. To demonstrate technical feasibility we present a phantom study. Methods: We utilize a realistic anthropomorphic dynamic thorax phantom with a lung tumor model embedded close to the spine. The tumor, amore » 3D-printout of a patient's GTV, is moved 15mm peak-to-peak by diaphragm compression and monitored by continuous EPID imaging in real-time. Two treatment apertures are created for each beam, one representing ITV -based and the other GTV-based margin expansion. A soft tissue localization (STiL) algorithm utilizing the continuous EPID images is employed to freeze tumor motion within the treatment aperture by means of DMLC tracking. Depending on a tracking confidence measure (TCM), the treatment aperture is adjusted between the ITV and the GTV leaf. Results: We successfully demonstrate real-time personalized margin adjustment in a phantom study. We measured a system latency of about 250 ms which we compensated by utilizing a respiratory motion prediction algorithm (ridge regression). With prediction in place we observe tracking accuracies better than 1mm. For TCM=0 (as during startup) an ITV-based treatment aperture is chosen, for TCM=1 a GTV-based aperture and for 0« less
NASA Astrophysics Data System (ADS)
Xie, Yaoqin; Xing, Lei; Gu, Jia; Liu, Wu
2013-06-01
Real-time knowledge of tumor position during radiation therapy is essential to overcome the adverse effect of intra-fractional organ motion. The goal of this work is to develop a tumor tracking strategy by effectively utilizing the inherent image features of stereoscopic x-ray images acquired during dose delivery. In stereoscopic x-ray image guided radiation delivery, two orthogonal x-ray images are acquired either simultaneously or sequentially. The essence of markerless tumor tracking is the reliable identification of inherent points with distinct tissue features on each projection image and their association between two images. The identification of the feature points on a planar x-ray image is realized by searching for points with high intensity gradient. The feature points are associated by using the scale invariance features transform descriptor. The performance of the proposed technique is evaluated by using images of a motion phantom and four archived clinical cases acquired using either a CyberKnife equipped with a stereoscopic x-ray imaging system, or a LINAC equipped with an onboard kV imager and an electronic portal imaging device. In the phantom study, the results obtained using the proposed method agree with the measurements to within 2 mm in all three directions. In the clinical study, the mean error is 0.48 ± 0.46 mm for four patient data with 144 sequential images. In this work, a tissue feature-based tracking method for stereoscopic x-ray image guided radiation therapy is developed. The technique avoids the invasive procedure of fiducial implantation and may greatly facilitate the clinical workflow.
Fröberg, Åsa; Mårtensson, Mattias; Larsson, Matilda; Janerot-Sjöberg, Birgitta; D'Hooge, Jan; Arndt, Anton
2016-10-01
Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 ± 0.08%). The absolute error in peak strain varied between 0.72 ± 0.65% and 10.64 ± 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4 Hz had lower errors than 78.6 Hz as was the case with a 22 mm compared to an 11 mm ROI. Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon. © The Foundation Acta Radiologica 2016.
NASA Astrophysics Data System (ADS)
Clements, Logan W.; Collins, Jarrod A.; Wu, Yifei; Simpson, Amber L.; Jarnagin, William R.; Miga, Michael I.
2015-03-01
Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been performed via phantom experiments. Tracked intraoperative ultrasound (iUS) provides a means to digitize sub-surface anatomical landmarks during clinical procedures. The proposed method involves the validation of a deformation correction algorithm for open hepatic image-guided surgery systems via sub-surface targets digitized with tracked iUS. Intraoperative surface digitizations were acquired via a laser range scanner and an optically tracked stylus for the purposes of computing the physical-to-image space registration within the guidance system and for use in retrospective deformation correction. Upon completion of surface digitization, the organ was interrogated with a tracked iUS transducer where the iUS images and corresponding tracked locations were recorded. After the procedure, the clinician reviewed the iUS images to delineate contours of anatomical target features for use in the validation procedure. Mean closest point distances between the feature contours delineated in the iUS images and corresponding 3-D anatomical model generated from the preoperative tomograms were computed to quantify the extent to which the deformation correction algorithm improved registration accuracy. The preliminary results for two patients indicate that the deformation correction method resulted in a reduction in target error of approximately 50%.
Harris, Paul A.; Kirby, Jacqueline; Swafford, Jonathan A.; Edwards, Terri L.; Zhang, Minhua; Yarbrough, Tonya R.; Lane, Lynda D.; Helmer, Tara; Bernard, Gordon R.; Pulley, Jill M.
2015-01-01
Peer-reviewed publications are one measure of scientific productivity. From a project, program, or institutional perspective, publication tracking provides the quantitative data necessary to guide the prudent stewardship of federal, foundation, and institutional investments by identifying the scientific return for the types of support provided. In this article, the authors describe the Vanderbilt Institute for Clinical and Translational Research’s (VICTR’s) development and implementation of a semi-automated process through which publications are automatically detected in PubMed and adjudicated using a “just-in-time” workflow by a known pool of researchers (from Vanderbilt University School of Medicine and Meharry Medical College) who receive support from Vanderbilt’s Clinical and Translational Science Award. Since implementation, the authors have: (1) seen a marked increase in the number of publications citing VICTR support; (2) captured at a more granular level the relationship between specific resources/services and scientific output; (3) increased awareness of VICTR’s scientific portfolio; and (4) increased efficiency in complying with annual National Institutes of Health progress reports. They present the methodological framework and workflow, measures of impact for the first 30 months, and a set of practical lessons learned to inform others considering a systems-based approach for resource and publication tracking. They learned that contacting multiple authors from a single publication can increase the accuracy of the resource attribution process in the case of multidisciplinary scientific projects. They also found that combining positive (e.g., congratulatory e-mails) and negative (e.g., not allowing future resource requests until adjudication is complete) triggers can increase compliance with publication attribution requests. PMID:25901872
MO-FG-BRD-00: Real-Time Imaging and Tracking Techniques for Intrafractional Motion Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
Intrafraction target motion is a prominent complicating factor in the accurate targeting of radiation within the body. Methods compensating for target motion during treatment, such as gating and dynamic tumor tracking, depend on the delineation of target location as a function of time during delivery. A variety of techniques for target localization have been explored and are under active development; these include beam-level imaging of radio-opaque fiducials, fiducial-less tracking of anatomical landmarks, tracking of electromagnetic transponders, optical imaging of correlated surrogates, and volumetric imaging within treatment delivery. The Joint Imaging and Therapy Symposium will provide an overview of the techniquesmore » for real-time imaging and tracking, with special focus on emerging modes of implementation across different modalities. In particular, the symposium will explore developments in 1) Beam-level kilovoltage X-ray imaging techniques, 2) EPID-based megavoltage X-ray tracking, 3) Dynamic tracking using electromagnetic transponders, and 4) MRI-based soft-tissue tracking during radiation delivery. Learning Objectives: Understand the fundamentals of real-time imaging and tracking techniques Learn about emerging techniques in the field of real-time tracking Distinguish between the advantages and disadvantages of different tracking modalities Understand the role of real-time tracking techniques within the clinical delivery work-flow.« less
Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes
NASA Astrophysics Data System (ADS)
Pettersen, H. E. S.; Alme, J.; Biegun, A.; van den Brink, A.; Chaar, M.; Fehlker, D.; Meric, I.; Odland, O. H.; Peitzmann, T.; Rocco, E.; Ullaland, K.; Wang, H.; Yang, S.; Zhang, C.; Röhrich, D.
2017-07-01
Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the target volume in a patient. Imaging methods and modalities, such as Dual Energy CT and proton CT, have come into consideration in the pursuit of obtaining an as good as possible estimate of the proton stopping power. In this study, a Digital Tracking Calorimeter is benchmarked for proof-of-concept for proton CT purposes. The Digital Tracking Calorimeter was originally designed for the reconstruction of high-energy electromagnetic showers for the ALICE-FoCal project. The presented prototype forms the basis for a proton CT system using a single technology for tracking and calorimetry. This advantage simplifies the setup and reduces the cost of a proton CT system assembly, and it is a unique feature of the Digital Tracking Calorimeter concept. Data from the AGORFIRM beamline at KVI-CART in Groningen in the Netherlands and Monte Carlo simulation results are used to in order to develop a tracking algorithm for the estimation of the residual ranges of a high number of concurrent proton tracks. High energy protons traversing the detector leave a track through the sensor layers. These tracks are spread out through charge diffusion processes. A charge diffusion model is applied for acquisition of estimates of the deposited energy of the protons in each sensor layer by using the size of the charge diffused area. A model fit of the Bragg Curve is applied to each reconstructed track and through this, estimating the residual range of each proton. The range of the individual protons can at present be estimated with a resolution of 4%. The readout system for this prototype is able to handle an effective proton frequency of 1 MHz by using 500 concurrent proton tracks in each readout frame, which is at the high end range of present similar prototypes. A future further optimized prototype will enable a high-speed and more accurate determination of the ranges of individual protons in a therapeutic beam.
Sandgren, Olof; Andersson, Richard; van de Weijer, Joost; Hansson, Kristina; Sahlén, Birgitta
2012-01-01
This study investigates gaze behaviour in child dialogues. In earlier studies the authors have investigated the use of requests for clarification and responses in order to study the co-creation of understanding in a referential communication task. By adding eye tracking, this line of research is now expanded to include non-verbal contributions in conversation. To investigate the timing of gazes in face-to-face interaction and to relate the gaze behaviour to the use of requests for clarification. Eight conversational pairs of typically developing 10-15 year olds participated. The pairs (director and executor) performed a referential communication task requiring the description of faces. During the dialogues both participants wore head-mounted eye trackers. All gazes were recorded and categorized according to the area fixated (Task, Face, Off). The verbal context for all instances of gaze at the partner's face was identified and categorized using time-course analysis. The results showed that the executor spends almost 90% of the time fixating the gaze on the task, 10% on the director's face and less than 0.5% elsewhere. Turn shift, primarily requests for clarification, and back channelling significantly predicted the executors' gaze to the face of the task director. The distribution of types of requests showed that requests for previously unmentioned information were significantly more likely to be associated with gaze at the director. The study shows that the executors' gaze at the director accompanies important dynamic shifts in the dialogue. The association with requests for clarification indicates that gaze at the director can be used to monitor the response with two modalities. Furthermore, the significantly higher association with requests for previously unmentioned information indicates that gaze may be used to emphasize the verbal content. The results will be used as a reference for studies of gaze behaviour in clinical populations with hearing and language impairments. © 2012 Royal College of Speech and Language Therapists.
Accuracy analysis for triangulation and tracking based on time-multiplexed structured light.
Wagner, Benjamin; Stüber, Patrick; Wissel, Tobias; Bruder, Ralf; Schweikard, Achim; Ernst, Floris
2014-08-01
The authors' research group is currently developing a new optical head tracking system for intracranial radiosurgery. This tracking system utilizes infrared laser light to measure features of the soft tissue on the patient's forehead. These features are intended to offer highly accurate registration with respect to the rigid skull structure by means of compensating for the soft tissue. In this context, the system also has to be able to quickly generate accurate reconstructions of the skin surface. For this purpose, the authors have developed a laser scanning device which uses time-multiplexed structured light to triangulate surface points. The accuracy of the authors' laser scanning device is analyzed and compared for different triangulation methods. These methods are given by the Linear-Eigen method and a nonlinear least squares method. Since Microsoft's Kinect camera represents an alternative for fast surface reconstruction, the authors' results are also compared to the triangulation accuracy of the Kinect device. Moreover, the authors' laser scanning device was used for tracking of a rigid object to determine how this process is influenced by the remaining triangulation errors. For this experiment, the scanning device was mounted to the end-effector of a robot to be able to calculate a ground truth for the tracking. The analysis of the triangulation accuracy of the authors' laser scanning device revealed a root mean square (RMS) error of 0.16 mm. In comparison, the analysis of the triangulation accuracy of the Kinect device revealed a RMS error of 0.89 mm. It turned out that the remaining triangulation errors only cause small inaccuracies for the tracking of a rigid object. Here, the tracking accuracy was given by a RMS translational error of 0.33 mm and a RMS rotational error of 0.12°. This paper shows that time-multiplexed structured light can be used to generate highly accurate reconstructions of surfaces. Furthermore, the reconstructed point sets can be used for high-accuracy tracking of objects, meeting the strict requirements of intracranial radiosurgery.
Tracking Emotional Valence: The Role of the Orbitofrontal Cortex
Goodkind, Madeleine S.; Sollberger, Marc; Gyurak, Anett; Rosen, Howard J.; Rankin, Katherine; Miller, Bruce; Levenson, Robert
2011-01-01
Successful navigation of the social world requires the ability to recognize and track emotions as they unfold and change dynamically. Neuroimaging and neurological studies of emotion recognition have primarily focused on the ability to identify the emotion shown in static photographs of facial expressions, showing correlations with the amygdala as well as temporal and frontal brain regions. In the current study we examined the neural correlates of continuously tracking dynamically-changing emotions. Fifty-nine patients with diverse neurodegenerative diseases used a rating dial to track continuously how positive or how negative the character in a film clip felt. Tracking accuracy was determined by comparing participants’ ratings with the ratings of 10 normal control participants. The relationship between tracking accuracy and regional brain tissue content was examined using voxel-based morphometry. Low tracking accuracy was primarily associated with gray matter loss in the right lateral orbitofrontal cortex (OFC). Our finding that the right OFC is critical to the ability to track dynamically-changing emotions is consistent with previous research showing right OFC involvement in both socioemotional understanding and modifying responding in changing situations. PMID:21425397
Improvements Needed With Tracking and Configuring Army Commercial Mobile Devices
2013-03-26
and Windows mobile operating systems. In addition, we excluded BlackBerry devices because the DoD OIG issued a report on September 25, 2009...Controls Over Information Contained in BlackBerry Devices Used Within DoD” (DoD IG Report No. D-2009-111). Furthermore, our review focused on the use...enterprise. CMDs Used by Army Activities Visited We conducted a datacall requesting a list of all smartphones (excluding BlackBerry devices) and
2004-09-01
agency response letters are included in Appendix B. Mr. Robert W. GoUedge, Jr. Commissioner, MADEP: No Comment Mr. Garry C. Waldeck MADEP...Headquarters: -Requested copy of Environmental Assessment ( No comment ). Mr. David Shakespeare MADEP - BWSC: No Comment Mr. James Sprague , ·. MADEP, NERO...Division of Watershed Management - Wetlands Program: No Comment · Mr. John Zajac MADEP, NERO Division ofWatershed Management: No Comment Mr. Todd
An FPGA-Based System for Tracking Digital Information Transmitted Via Peer-to-Peer Protocols
2009-03-01
Sullivan. ISPs are Pressed to Become Child Porn Cops, October 2008. http://www.msnbc.msn.com/id/27198621. DVR07. Hamza Dahmouni, Sandrine Vaton, and David...of child pornography. The Federal Bureau of Investigation’s (FBI) Re- gional Computer Forensics Laboratory states in its 2007 annual report that...cyber- crime, which includes crimes against children and child pornography, is the offense for which law enforcement requested assistance most often
77 FR 37426 - Agency Information Collection Activities: Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-21
... collection of information; (c) ways to enhance the quality, utility, and clarity of the information to be... History 13 50 650 0.17 110.5 15 1,658 Sub Total 52 8,450 452 6,780 FY 2008, FY 2009, and FY 2010 Grantees... Person Tracking 7 50 350 0.1 36 15 540 Service Use 7 50 350 0.17 59.5 15 893 Arrest History 7 50 350 0.17...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moran, James J.; Doll, Charles G.; Bernstein, Hans C.
2014-08-25
This is a manuscript we would like to submit for publication in Environmental Microbiology Reports. This manuscript contains a description of a laser ablation isotope ratio mass spectrometry methodology developed at PNNL and applied to a microbial system at a PNNL project location – Hot Lake, Washington. I will submit a word document containing the entire manuscript with this Erica input request form.
Greenland 1979 microwave remote sensing data catalog report, 14-15 October 1979
NASA Technical Reports Server (NTRS)
Hennigar, H. F.; Hirstein, W. S.; Schaffner, S. K.; Delnore, V. E.; Grantham, W. L.
1983-01-01
Microwave remote sensing measurements were cataloged for active and passive instruments in support of the 1979 Greenland Remote Sensing Experiment. Instruments used in this field experiment include the stepped frequency microwave radiometer (4 to 8 GHz) and the airborne microwave scatterometer (14.6 GHz). The microwave signature data are inventoried and cataloged in a user friendly format and are available on 9 track computer compatible tapes upon request.
Data to Action: Using Environmental Public Health Tracking to Inform Decision Making
Qualters, Judith R; Strosnider, Heather M; Bell, Rosalyn
2017-01-01
Context Public health surveillance includes dissemination of data and information to those who need it to take action to prevent or control disease. The concept of data to action is explicit in the mission of the Centers for Disease Control and Prevention’s (CDC) National Environmental Public Health Tracking Program (Tracking Program). CDC has built a National Environmental Public Health Tracking Network (Tracking Network) to integrate health and environmental data to drive public health action (PHA) to improve communities’ health. Objective To assess the utility of the Tracking Program and its Network in environmental public health practice and policy-making. Design We analyzed information on how Tracking has been used to drive PHAs within funded states and cities (grantees). Two case studies illustrate such use. Setting Analyses included all grantees funded between 2005 and 2013. Participants The number of grantees varied from 17 for 2006–2008 to 24 for 2010–2013. Main Outcome Measures We categorized each PHA reported to determine how grantees became involved, their role, the problems addressed, and the overall action. Results Tracking grantees reported 178 PHAs from 2006–2013. The most common overall action was “provided information in response to concern” (n=42) followed by “improved a public health program, intervention, or response plan” (n=35). Tracking’s role was most often to enhance surveillance (24%) or to analyze data (23%). In 47% of PHAs, the underlying problem was a concern about possible elevated rates of a health outcome, a potential exposure, or a potential association between a hazard and health. PHAs were started by a request for assistance (48%), in response to an emergency (8%), and though routine work by Tracking programs (43%). Conclusion Our review shows that the data, expertise, technical infrastructure, and other resources of the Tracking Program and its Network are driving state and local PHAs. PMID:25621441
Converting from DDOR SASF to APF
NASA Technical Reports Server (NTRS)
Gladden, Roy E.; Khanampompan, Teerapat; Fisher, Forest W.
2008-01-01
A computer program called ddor_sasf2apf converts delta-door (delta differential one-way range) request from an SASF (spacecraft activity sequence file) format to an APF (apgen plan file) format for use in the Mars Reconnaissance Orbiter (MRO) missionplanning- and-sequencing process. The APF is used as an input to APGEN/AUTOGEN in the MRO activity- planning and command-sequencegenerating process to sequence the delta-door (DDOR) activity. The DDOR activity is a spacecraft tracking technique for determining spacecraft location. The input to ddor_sasf2apf is an input request SASF provided by an observation team that utilizes DDOR. ddor_sasf2apf parses this DDOR SASF input, rearranging parameters and reformatting the request to produce an APF file for use in AUTOGEN and/or APGEN. The benefit afforded by ddor_sasf2apf is to enable the use of the DDOR SASF file earlier in the planning stage of the command-sequence-generating process and to produce sequences, optimized for DDOR operations, that are more accurate and more robust than would otherwise be possible.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... blood or tissues can result in obstruction of blood flow or pressure effects. Clinical manifestations of... Tables,(3) Information on related control measures (e.g., engineering controls, work practices, personal...
Xie, Hao-ran; Li, Fang-chun; Zhang, Wei-bo
2009-06-01
In the present paper the authors analyze the anatomical structure of the meridian running track by using the dialectical thought and comprehensive analysis of the integrated Chinese and western medicine. It has been observed that the "Qi-passages" of the 14 meridians of Chinese medicine are located in the connective tissue among the interspace of the muscles, etc. distributing longitudinally. The "Qi-passages" of the 15 Luomai (collaterals of the meridians) are located in the connective tissue among the interspace of the muscles, etc. distributing transversally, while those of the small branches of the meridian collaterals are located in the interspace mesenchyme of the muscle bundles distributing in the whole body. The "Qi-passages" of the tiny branches of the meridian collaterals are located in the mesenchyme of the intracellular space, such as the muscle fibers in the whole body. The authors hold that the so-called "Mai Qi" of the meridian-collaterals is the liquid-Qi flowing in the vertical and horizontal tissue interspaces. The "Qi-passage" of the meridian-collaterals of Chinese medicine is the pathway of the liquid-Qi of the tissue interspaces. The structure of the meridian-collaterals is the tissue interspace. The meridian-collateral system is a regulation-control system in the human body where the Qi-passages communicate with each other, and is, in fact, the protoplasm, the liquid-Qi circulating in the tissue interspaces.
Debriding effect of bromelain on firearm wounds in pigs.
Hu, Wei; Wang, Ai-Min; Wu, Si-Yu; Zhang, Bo; Liu, Shuai; Gou, Yuan-Bin; Wang, Jian-Min
2011-10-01
Wound excision is the standard treatment for firearm wounds. However, achieving a satisfactory curative effect is difficult because of the traumatic mechanism of high-velocity projectiles. We propose a new therapy by using topical bromelain as a supplement to wound incision for the debridement of firearm wounds. We clarified the debriding effect of bromelain on firearm wounds in pigs. In vitro, muscle tissues around the wound track and normal muscle were incubated in bromelain solutions of different concentrations. Tissue hydrolization was estimated by measuring tissue weight and the release of total amino acids. In vivo, the hind limbs of 15 pigs were wounded with high-velocity projectiles. Five groups were classified as follows: wound excision (E), wound incision (I), bromelain (B), incision + bromelain (IB), and control (C). Debriding effectiveness was estimated using bacterial content, histopathologic examination, and wound healing time. In vitro, hydrolization of wound tissue was significantly more intensive than that of normal tissue. Bromelain solution (10 mg/mL) hydrolyzed wound tissue rapidly with minimal proteolysis of normal tissue. In vivo, the wound-track bacterial content of group IB was similar to that of group E and was significantly lower than that of groups I, B, and C. The wound healing time of group IB was also shorter. Bromelain is effective in the debridement of uncomplicated firearm wounds if used as a supplement to simple wound incision. This new therapy shows notable advantages over conventional surgical debridement as it greatly simplifies the procedures.
Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures
NASA Astrophysics Data System (ADS)
Xia, Wenfeng; Mosse, Charles A.; Colchester, Richard J.; Mari, Jean Martial; Nikitichev, Daniil I.; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2015-07-01
In a wide range of clinical procedures, accurate placement of medical devices such as needles and catheters is critical to optimize patient outcomes. Ultrasound imaging is often used to guide minimally invasive procedures, as it can provide real-time visualization of patient anatomy and medical devices. However, this modality can provide low image contrast for soft tissues, and poor visualization of medical devices that are steeply angled with respect to the incoming ultrasound beams. Photoacoustic sensors can provide information about the spatial distributions of tissue chromophores that could be valuable for guiding minimally invasive procedures. In this study, a system for guiding minimally invasive procedures using photoacoustic sensing was developed. This system included a miniature photoacoustic probe with three optical fibers: one with a bare end for photoacoustic excitation of tissue, a second for photoacoustic excitation of an optically absorbing coating at the distal end to transmit ultrasound, and a third with a Fabry-Perot cavity at the distal end for receiving ultrasound. The position of the photoacoustic probe was determined with ultrasonic tracking, which involved transmitting pulses from a linear-array ultrasound imaging probe at the tissue surface, and receiving them with the fiber-optic ultrasound receiver in the photoacoustic probe. The axial resolution of photoacoustic sensing was better than 70 μm, and the tracking accuracy was better than 1 mm in both axial and lateral dimensions. By translating the photoacoustic probe, depth scans were obtained from different spatial positions, and two-dimensional images were reconstructed using a frequency-domain algorithm.
Potential benefits of dosimetric VMAT tracking verified with 3D film measurements.
Crijns, Wouter; Defraene, Gilles; Van Herck, Hans; Depuydt, Tom; Haustermans, Karin; Maes, Frederik; Van den Heuvel, Frank
2016-05-01
To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution's position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.
Li, Qiang; Liu, Hao-Li; Chen, Wen-Shiang
2013-01-01
Previous studies developed ultrasound temperature-imaging methods based on changes in backscattered energy (CBE) to monitor variations in temperature during hyperthermia. In conventional CBE imaging, tracking and compensation of the echo shift due to temperature increase need to be done. Moreover, the CBE image does not enable visualization of the temperature distribution in tissues during nonuniform heating, which limits its clinical application in guidance of tissue ablation treatment. In this study, we investigated a CBE imaging method based on the sliding window technique and the polynomial approximation of the integrated CBE (ICBEpa image) to overcome the difficulties of conventional CBE imaging. We conducted experiments with tissue samples of pork tenderloin ablated by microwave irradiation to validate the feasibility of the proposed method. During ablation, the raw backscattered signals were acquired using an ultrasound scanner for B-mode and ICBEpa imaging. The experimental results showed that the proposed ICBEpa image can visualize the temperature distribution in a tissue with a very good contrast. Moreover, tracking and compensation of the echo shift were not necessary when using the ICBEpa image to visualize the temperature profile. The experimental findings suggested that the ICBEpa image, a new CBE imaging method, has a great potential in CBE-based imaging of hyperthermia and other thermal therapies. PMID:24260041
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I.; Letts, Robyn F. R.; Pantanowitz, Adam; Rubin, David M.; Thomsen, Jesper S.; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron. PMID:26170896
Towards Automated Three-Dimensional Tracking of Nephrons through Stacked Histological Image Sets.
Bhikha, Charita; Andreasen, Arne; Christensen, Erik I; Letts, Robyn F R; Pantanowitz, Adam; Rubin, David M; Thomsen, Jesper S; Zhai, Xiao-Yue
2015-01-01
An automated approach for tracking individual nephrons through three-dimensional histological image sets of mouse and rat kidneys is presented. In a previous study, the available images were tracked manually through the image sets in order to explore renal microarchitecture. The purpose of the current research is to reduce the time and effort required to manually trace nephrons by creating an automated, intelligent system as a standard tool for such datasets. The algorithm is robust enough to isolate closely packed nephrons and track their convoluted paths despite a number of nonideal, interfering conditions such as local image distortions, artefacts, and interstitial tissue interference. The system comprises image preprocessing, feature extraction, and a custom graph-based tracking algorithm, which is validated by a rule base and a machine learning algorithm. A study of a selection of automatically tracked nephrons, when compared with manual tracking, yields a 95% tracking accuracy for structures in the cortex, while those in the medulla have lower accuracy due to narrower diameter and higher density. Limited manual intervention is introduced to improve tracking, enabling full nephron paths to be obtained with an average of 17 manual corrections per mouse nephron and 58 manual corrections per rat nephron.
Evaporation process in histological tissue sections for neutron autoradiography.
Espector, Natalia M; Portu, Agustina; Santa Cruz, Gustavo A; Saint Martin, Gisela
2018-05-01
The analysis of the distribution and density of nuclear tracks forming an autoradiography in a nuclear track detector (NTD) allows the determination of 10 B atoms concentration and location in tissue samples from Boron Neutron Capture Therapy (BNCT) protocols. This knowledge is of great importance for BNCT dosimetry and treatment planning. Tissue sections studied with this technique are obtained by cryosectioning frozen tissue specimens. After the slicing procedure, the tissue section is put on the NTD and the sample starts drying. The thickness varies from its original value allowing more particles to reach the detector and, as the mass of the sample decreases, the boron concentration in the sample increases. So in order to determine the concentration present in the hydrated tissue, the application of corrective coefficients is required. Evaporation mechanisms as well as various factors that could affect the process of mass variation are outlined in this work. Mass evolution for tissue samples coming from BDIX rats was registered with a semimicro analytical scale and measurements were analyzed with software developed to that end. Ambient conditions were simultaneously recorded, obtaining reproducible evaporation curves. Mathematical models found in the literature were applied for the first time to this type of samples and the best fit of the experimental data was determined. The correlation coefficients and the variability of the parameters were evaluated, pointing to Page's model as the one that best represented the evaporation curves. These studies will contribute to a more precise assessment of boron concentration in tissue samples by the Neutron Autoradiography technique.
NASA Astrophysics Data System (ADS)
Gray, Robert H. R.; Leslie, Thomas A.; Civale, John; Kennedy, James E.; ter Haar, Gail
2007-05-01
Real time ultrasound monitoring of tissue ablation in clinical HIFU treatments currently depends on the observation of the appearance of new hyperechoic regions within the target volume, allowing visually directed treatment. These grey-scale changes are attributed to the formation of gas or vapour bubbles. In this study, scanned track lesions have been formed in ex vivo bovine liver samples at a range of ablative intensities (free field spatial peak intensities 7 - 47 kW cm-2), and tracking speeds (1-2 mms-1). Their appearance on conventional B-mode ultrasound images has been assessed using digital imaging techniques over the first 60 seconds following HIFU exposure. The size of the lesion as seen on the ultrasound scan is compared to the macroscopic size of the lesion at dissection. It is seen that the lesion size is highly dependent on the intensity and scanning speed of the transducer. Reliable lesions can be created using scanned tracks at the lowest powers, with increased numbers of cycles, and grey-scale changes correlated strongly with the histological findings. Although not a highly sensitive indication of ablated area, ultrasound monitoring of treatment is highly specific thus confirming its clinical utility.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hu, Y; Rottmann, J; Myronakis, M
2016-06-15
Purpose: The purpose of this study was to quantify the improvement in tumor tracking, with and without fiducial markers, afforded by employing a multi-layer (MLI) electronic portal imaging device (EPID) over the current state-of-the-art, single-layer, digital megavolt imager (DMI) architecture. Methods: An ideal observer signal-to-noise ratio (d’) approach was used to quantify the ability of an MLI EPID and a current, state-of-the-art DMI EPID to track lung tumors from the treatment beam’s-eye-view. Using each detector modulation transfer function (MTF) and noise power spectrum (NPS) as inputs, a detection task was employed with object functions describing simple three-dimensional Cartesian shapes (spheresmore » and cylinders). Marker-less tumor tracking algorithms often use texture discrimination to differentiate benign and malignant tissue. The performance of such algorithms is simulated by employing a discrimination task for the ideal observer, which measures the ability of a system to differentiate two image quantities. These were defined as the measured textures for benign and malignant lung tissue. Results: The NNPS of the MLI ∼25% of that of the DMI at the expense of decreased MTF at intermediate frequencies (0.25≤« less
Geometric reconstruction using tracked ultrasound strain imaging
NASA Astrophysics Data System (ADS)
Pheiffer, Thomas S.; Simpson, Amber L.; Ondrake, Janet E.; Miga, Michael I.
2013-03-01
The accurate identification of tumor margins during neurosurgery is a primary concern for the surgeon in order to maximize resection of malignant tissue while preserving normal function. The use of preoperative imaging for guidance is standard of care, but tumor margins are not always clear even when contrast agents are used, and so margins are often determined intraoperatively by visual and tactile feedback. Ultrasound strain imaging creates a quantitative representation of tissue stiffness which can be used in real-time. The information offered by strain imaging can be placed within a conventional image-guidance workflow by tracking the ultrasound probe and calibrating the image plane, which facilitates interpretation of the data by placing it within a common coordinate space with preoperative imaging. Tumor geometry in strain imaging is then directly comparable to the geometry in preoperative imaging. This paper presents a tracked ultrasound strain imaging system capable of co-registering with preoperative tomograms and also of reconstructing a 3D surface using the border of the strain lesion. In a preliminary study using four phantoms with subsurface tumors, tracked strain imaging was registered to preoperative image volumes and then tumor surfaces were reconstructed using contours extracted from strain image slices. The volumes of the phantom tumors reconstructed from tracked strain imaging were approximately between 1.5 to 2.4 cm3, which was similar to the CT volumes of 1.0 to 2.3 cm3. Future work will be done to robustly characterize the reconstruction accuracy of the system.
Brama, Elisabeth; Peddie, Christopher J; Wilkes, Gary; Gu, Yan; Collinson, Lucy M; Jones, Martin L
2016-12-13
In-resin fluorescence (IRF) protocols preserve fluorescent proteins in resin-embedded cells and tissues for correlative light and electron microscopy, aiding interpretation of macromolecular function within the complex cellular landscape. Dual-contrast IRF samples can be imaged in separate fluorescence and electron microscopes, or in dual-modality integrated microscopes for high resolution correlation of fluorophore to organelle. IRF samples also offer a unique opportunity to automate correlative imaging workflows. Here we present two new locator tools for finding and following fluorescent cells in IRF blocks, enabling future automation of correlative imaging. The ultraLM is a fluorescence microscope that integrates with an ultramicrotome, which enables 'smart collection' of ultrathin sections containing fluorescent cells or tissues for subsequent transmission electron microscopy or array tomography. The miniLM is a fluorescence microscope that integrates with serial block face scanning electron microscopes, which enables 'smart tracking' of fluorescent structures during automated serial electron image acquisition from large cell and tissue volumes.
Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service
NASA Technical Reports Server (NTRS)
Allard, Daniel A.; Wallick, Michael N.; Gladden, Roy E.; Wang, Paul; Hy, Franklin H.
2013-01-01
This software provides a new set of capabilities for the Mars Relay Operations Service (MaROS) in support of Strategic and Tactical relay, including a highly interactive relay request Web user interface, mission control over relay planning time periods, and mission management of allowed strategic vs. tactical request parameters. Together, these new capabilities expand the scope of the system to include all elements critical for Tactical relay operations. Planning of replay activities spans a time period that is split into two distinct phases. The first phase is called Strategic, which begins at the time that relay opportunities are identified, and concludes at the point that the orbiter generates the flight sequences for on board execution. Any relay request changes from this point on are called Tactical. Tactical requests, otherwise called Orbit - er Relay State Changes (ORSC), are highly restricted in terms of what types of changes can be made, and the types of parameters that can be changed may differ from one orbiter to the next. For example, one orbiter may be able to delay the start of a relay request, while another may not. The legacy approach to ORSC management involves exchanges of e-mail with "requests for change" and "acknowledgement of approval," with no other tracking of changes outside of e-mail folders. MaROS Phases 1 and 2 provided the infrastructure for strategic relay for all supported missions. This new version, 3.0, introduces several capabilities that fully expand the scope of the system to include tactical relay. One new feature allows orbiter users to manage and "lock" Planning Periods, which allows the orbiter team to formalize the changeover from Strategic to Tactical operations. Another major feature allows users to interactively submit tactical request changes via a Web user interface. A third new feature allows orbiter missions to specify allowed tactical updates, which are automatically incorporated into the tactical change process. This software update is significant in that it provides the only centralized service for tactical request management available for relay missions.
MR techniques for guiding high-intensity focused ultrasound (HIFU) treatments.
Kuroda, Kagayaki
2018-02-01
To make full use of the ability of magnetic resonance (MR) to guide high-intensity focused ultrasound (HIFU) treatment, effort has been made to improve techniques for thermometry, motion tracking, and sound beam visualization. For monitoring rapid temperature elevation with proton resonance frequency (PRF) shift, data acquisition and processing can be accelerated with parallel imaging and/or sparse sampling in conjunction with appropriate signal processing methods. Thermometry should be robust against tissue motion, motion-induced magnetic field variation, and susceptibility change. Thus, multibaseline, referenceless, or hybrid techniques have become important. In cases with adipose or bony tissues, for which PRF shift cannot be used, thermometry with relaxation times or signal intensity may be utilized. Motion tracking is crucial not only for thermometry but also for targeting the focus of an ultrasound in moving organs such as the liver, kidney, or heart. Various techniques for motion tracking, such as those based on an anatomical image atlas with optical-flow displacement detection, a navigator echo to seize the diaphragm position, and/or rapid imaging to track vessel positions, have been proposed. Techniques for avoiding the ribcage and near-field heating have also been examined. MR acoustic radiation force imaging (MR-ARFI) is an alternative to thermometry that can identify the location and shape of the focal spot and sound beam path. This technique could be useful for treating heterogeneous tissue regions or performing transcranial therapy. All of these developments, which will be discussed further in this review, expand the applicability of HIFU treatments to a variety of clinical targets while maintaining safety and precision. 2 Technical Efficacy: Stage 4 J. Magn. Reson. Imaging 2018;47:316-331. © 2017 International Society for Magnetic Resonance in Medicine.
Inoue, S
1995-02-01
The ultrastructural organization of connective tissue microfibrils was studied in the mouse eye and also by means of in vitro experiments for reconstituting microfibrils. In the posterior chamber of the eye of the C57BL/6J mouse, 3 nm-wide ribbon-like double-tracked structures were present and were periodically associated on either side with 3.5 nm-wide particulate structures identified as pentosomes, the subunits of amyloid P component (AP). At certain sites, such composite structures were observed in various stages of helical winding, and in these helices, pentosomes were preferentially localized internally. In helices in the final stages of winding, the resulting rods appeared increasingly similar to those of microfibrils. In experiments in vitro, incubation of chondroitin sulfate proteoglycan (CSPG) in TRIS buffer, pH 7.4, at 35 degrees C for 1 h produced random aggregates of 3 nm-wide double-tracked structures similar to those observed in the eye. Co-incubation of CSPG and AP resulted in the formation of rod-like structures arranged parallel to one another in approximately 50 nm-thick sheet-like layers. These rods were ultrastructurally similar to microfibrils and were made up of helically wound, 3 nm-wide double-tracked structures containing pentosomes within their core. The results of in vivo as well as in vitro experiments suggest the possibility that the connective tissue microfibril is composed of helically wound, CSPG-containing, 3 nm-wide double-tracked structures periodically associated with pentosomes which, as the helix becomes progressively tighter, fit with one another at the core of the helix to form successive 8.5 nm-wide disks of AP segments.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-10
.... supply of blood and blood components, tissues, cells, and organs. The original RFI was published in the... the Secretary, U.S. Department of Health and Human Services, 1101 Wootton Parkway, Tower Building...
PROJECT GREENSHORES HABITAT RESTORATION AND MONITORING PROJECT MX974850
The requested funding will support this Tissue Culture Laboratory and the Coastal and Wetland Plant nursery and provide plant propagation materials (potting soil, fertilizer, growth hormones, pots, trays, test tubes, racks, etc.) for 12 months. Plants propagated by this funding...
The electronic, 'paperless' medical office; has it arrived?
Gates, P; Urquhart, J
2007-02-01
Modern information technology offers efficiencies in medical practice, with a reduction in secretarial time in maintaining, filing and retrieving the paper medical record. Electronic requesting of investigations allows tracking of outstanding results. Less storage space is required and telephone calls from pharmacies, pathology and medical imaging service providers to clarify the hand-written request are abolished. Voice recognition software reduces secretarial typing time per letter. These combined benefits can lead to significantly reduced costs and improved patient care. The paperless office is possible, but requires commitment and training of all staff; it is preferable but not absolutely essential that at least one member of the practice has an interest and some expertise in computers. More importantly, back-up from information technology providers and back-up of the electronic data are absolutely crucial and a paperless environment should not be considered without them.
Real-time ultrasound-tagging to track the 2D motion of the common carotid artery wall in vivo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zahnd, Guillaume, E-mail: g.zahnd@erasmusmc.nl; Salles, Sébastien; Liebgott, Hervé
2015-02-15
Purpose: Tracking the motion of biological tissues represents an important issue in the field of medical ultrasound imaging. However, the longitudinal component of the motion (i.e., perpendicular to the beam axis) remains more challenging to extract due to the rather coarse resolution cell of ultrasound scanners along this direction. The aim of this study is to introduce a real-time beamforming strategy dedicated to acquire tagged images featuring a distinct pattern in the objective to ease the tracking. Methods: Under the conditions of the Fraunhofer approximation, a specific apodization function was applied to the received raw channel data, in real-time duringmore » image acquisition, in order to introduce a periodic oscillations pattern along the longitudinal direction of the radio frequency signal. Analytic signals were then extracted from the tagged images, and subpixel motion tracking of the intima–media complex was subsequently performed offline, by means of a previously introduced bidimensional analytic phase-based estimator. Results: The authors’ framework was applied in vivo on the common carotid artery from 20 young healthy volunteers and 6 elderly patients with high atherosclerosis risk. Cine-loops of tagged images were acquired during three cardiac cycles. Evaluated against reference trajectories manually generated by three experienced analysts, the mean absolute tracking error was 98 ± 84 μm and 55 ± 44 μm in the longitudinal and axial directions, respectively. These errors corresponded to 28% ± 23% and 13% ± 9% of the longitudinal and axial amplitude of the assessed motion, respectively. Conclusions: The proposed framework enables tagged ultrasound images of in vivo tissues to be acquired in real-time. Such unconventional beamforming strategy contributes to improve tracking accuracy and could potentially benefit to the interpretation and diagnosis of biomedical images.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crijns, Wouter, E-mail: wouter.crijns@uzleuven.be; Depuydt, Tom; Haustermans, Karin
Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3more » films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.« less
Comprehensive approach to image-guided surgery
NASA Astrophysics Data System (ADS)
Peters, Terence M.; Comeau, Roch M.; Kasrai, Reza; St. Jean, Philippe; Clonda, Diego; Sinasac, M.; Audette, Michel A.; Fenster, Aaron
1998-06-01
Image-guided surgery has evolved over the past 15 years from stereotactic planning, where the surgeon planned approaches to intracranial targets on the basis of 2D images presented on a simple workstation, to the use of sophisticated multi- modality 3D image integration in the operating room, with guidance being provided by mechanically, optically or electro-magnetically tracked probes or microscopes. In addition, sophisticated procedures such as thalamotomies and pallidotomies to relieve the symptoms of Parkinson's disease, are performed with the aid of volumetric atlases integrated with the 3D image data. Operations that are performed stereotactically, that is to say via a small burr- hole in the skull, are able to assume that the information contained in the pre-operative imaging study, accurately represents the brain morphology during the surgical procedure. On the other hand, preforming a procedure via an open craniotomy presents a problem. Not only does tissue shift when the operation begins, even the act of opening the skull can cause significant shift of the brain tissue due to the relief of intra-cranial pressure, or the effect of drugs. Means of tracking and correcting such shifts from an important part of the work in the field of image-guided surgery today. One approach has ben through the development of intra-operative MRI imaging systems. We describe an alternative approach which integrates intra-operative ultrasound with pre-operative MRI to track such changes in tissue morphology.
A systematic review on ricochet gunshot injuries.
Yong, Yuw-Er
2017-05-01
Ricocheted bullets may still retain sufficient kinetic energy to cause gunshot injuries. Accordingly, this paper reviews the literature surrounding gunshot injuries caused by ricocheted bullets. In doing so, it discusses the characteristics of ricochet entrance wounds and wound tracks, noting several important considerations for assessment of a possible ricochet incident. The shapes of ricochet entrance wounds vary, ranging from round holes to elliptical, large and irregular shapes. Pseudo-stippling or pseudo-gunpowder tattooing, pseudo-soot blackening and tumbling abrasions seen on the skin surrounding the bullet hole are particularly associated with ricochet incidents. Ricocheted bullets have a reduced capability for tissue penetration. Most of the resulting wound tracks are short, of large diameter and irregular-all artefacts of the instability of a bullet that has ricocheted. A ricocheted hollow-point bullet, in particular, may overpenetrate the tissue when the bullet nose is deformed or fails to enter the body in a nose-forward orientation. Similarly, internal ricochet may occur when a bullet strikes hard tissue. Postmortem computed tomographic imaging is useful for localising a bullet and its fragments in the body and characterising the wound track. Ricochet cannot be ruled out in normal-appearing entrance wounds unless that finding is supported by other evidence, including the geometrical constraints of the shooting scene and the absence of ricochet marks and a ricocheted bullet. Copyright © 2017 Elsevier B.V. All rights reserved.
Accurate tumor localization and tracking in radiation therapy using wireless body sensor networks.
Pourhomayoun, Mohammad; Jin, Zhanpeng; Fowler, Mark
2014-07-01
Radiation therapy is an effective method to combat cancerous tumors by killing the malignant cells or controlling their growth. Knowing the exact position of the tumor is a very critical prerequisite in radiation therapy. Since the position of the tumor changes during the process of radiation therapy due to the patient׳s movements and respiration, a real-time tumor tracking method is highly desirable in order to deliver a sufficient dose of radiation to the tumor region without damaging the surrounding healthy tissues. In this paper, we develop a novel tumor positioning method based on spatial sparsity. We estimate the position by processing the received signals from only one implantable RF transmitter. The proposed method uses less number of sensors compared to common magnetic transponder based approaches. The performance of the proposed method is evaluated in two different cases: (1) when the tissue configuration is perfectly determined (acquired beforehand by MRI or CT) and (2) when there are some uncertainties about the tissue boundaries. The results demonstrate the high accuracy and performance of the proposed method, even when the tissue boundaries are imperfectly known. Copyright © 2014 Elsevier Ltd. All rights reserved.
Geospatial Information is the Cornerstone of Effective Hazards Response
Newell, Mark
2008-01-01
Every day there are hundreds of natural disasters world-wide. Some are dramatic, whereas others are barely noticeable. A natural disaster is commonly defined as a natural event with catastrophic consequences for living things in the vicinity. Those events include earthquakes, floods, hurricanes, landslides, tsunami, volcanoes, and wildfires. Man-made disasters are events that are caused by man either intentionally or by accident, and that directly or indirectly threaten public health and well-being. These occurrences span the spectrum from terrorist attacks to accidental oil spills. To assist in responding to natural and potential man-made disasters, the U.S. Geological Survey (USGS) has established the Geospatial Information Response Team (GIRT) (http://www.usgs.gov/emergency/). The primary purpose of the GIRT is to ensure rapid coordination and availability of geospatial information for effective response by emergency responders, and land and resource managers, and for scientific analysis. The GIRT is responsible for establishing monitoring procedures for geospatial data acquisition, processing, and archiving; discovery, access, and delivery of data; anticipating geospatial needs; and providing relevant geospatial products and services. The GIRT is focused on supporting programs, offices, other agencies, and the public in mission response to hazards. The GIRT will leverage the USGS Geospatial Liaison Network and partnerships with the Department of Homeland Security (DHS), National Geospatial-Intelligence Agency (NGA), and Northern Command (NORTHCOM) to coordinate the provisioning and deployment of USGS geospatial data, products, services, and equipment. The USGS geospatial liaisons will coordinate geospatial information sharing with State, local, and tribal governments, and ensure geospatial liaison back-up support procedures are in place. The GIRT will coordinate disposition of USGS staff in support of DHS response center activities as requested by DHS. The GIRT is a standing team that is available during all hazard events and is on high alert during the hurricane season from June through November each year. To track all of the requirements and data acquisitions processed through the team, the GIRT will use the new Emergency Request Track (ER Track) tool. Currently, the ER Track is only available to USGS personnel.
Enhancing Brigade Combat Team Adaptability
2010-06-11
S3 DUTIES AND RESPONSIBILITIES S3 SGM S3 Operations Fires and EffectsS3 Training S3 Plans CYCLIC TNG GUIDANCE UNIT ASSESSMENT APPROVE DTU TOC/TAC SET...UP TEAM LEADER COURSE BOC MTT Requests/Tracking MTT OVERSIGHT TMPs RECLAMAS LOE OVERSIGHT MONITOR DIV O&I DTU /Task Management TOP 5 CALENDAR...referenced in Chapter 5 to this thesis. SLIDE: 1FOR OFFICIAL USE ONLY OPERATIONAL TASKS/SYSTEMS BOC Shift Change MONITOR DIV O&I DTU SDO BRIEFING
Chronology: From the Cambridge Field Station to the Air Force Geophysics Laboratory, 1945-1985
1985-09-06
Massachusetts. Early in the year the Air Research and Development Command approved AFCRC’s request for a new site at Plum Island, Newburyport...contained several new de- vices developed at AFCRC, including the light gun and an analog tracking computer (ANTRAC). Sep Establishment of the Upper Air...solar Lyman Alpha radiation from an Aerobee rocket using a new biaxial pointing control developed under contract by the University of Colorado. 29 Dec
ERIC Educational Resources Information Center
Moore, Colleen; Grubb, Brock; Esch, Camille
2016-01-01
Conventional wisdom suggests that local educators tend to be wary of efforts by the state to gather more information from their institutions, due to the burdens that such requests often entail. But California's current education landscape, with its shift from state to local control of funding and accountability in the K-12 system, its massive…
Intracellular pH in Gastric and Rectal Tissue Post Cardiac Arrest
NASA Astrophysics Data System (ADS)
Fisher, Elaine M.; Steiner, Richard P.; LaManna, Joseph C.
We directly measured pHi using the pH sensitive dye, neutral red. We defined pHi for rectal and gastric tissue in whole tissue and by layer under control and arrest conditions. Fifteen minutes of arrest was not sufficient time to alter the pHi at the rectal or gastric site. On initial inspection, the stomach may be more sensitive to ischemic changes than the rectum. Understanding the mechanism by which PCO2 generation is used to track clinical changes is vital to the early detection of tissue dysoxia in order to effectively treat and manage critically ill patients.
Giurumescu, Claudiu A; Kang, Sukryool; Planchon, Thomas A; Betzig, Eric; Bloomekatz, Joshua; Yelon, Deborah; Cosman, Pamela; Chisholm, Andrew D
2012-11-01
A quantitative understanding of tissue morphogenesis requires description of the movements of individual cells in space and over time. In transparent embryos, such as C. elegans, fluorescently labeled nuclei can be imaged in three-dimensional time-lapse (4D) movies and automatically tracked through early cleavage divisions up to ~350 nuclei. A similar analysis of later stages of C. elegans development has been challenging owing to the increased error rates of automated tracking of large numbers of densely packed nuclei. We present Nucleitracker4D, a freely available software solution for tracking nuclei in complex embryos that integrates automated tracking of nuclei in local searches with manual curation. Using these methods, we have been able to track >99% of all nuclei generated in the C. elegans embryo. Our analysis reveals that ventral enclosure of the epidermis is accompanied by complex coordinated migration of the neuronal substrate. We can efficiently track large numbers of migrating nuclei in 4D movies of zebrafish cardiac morphogenesis, suggesting that this approach is generally useful in situations in which the number, packing or dynamics of nuclei present challenges for automated tracking.
Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes
NASA Astrophysics Data System (ADS)
Bjerre, Troels; Crijns, Sjoerd; Rosenschöld, Per Munck af; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul
2013-07-01
The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.
Malide, Daniela; Métais, Jean-Yves; Dunbar, Cynthia E.
2014-01-01
We developed and validated a fluorescent marking methodology for clonal tracking of hematopoietic stem and progenitor cells (HSPCs) with high spatial and temporal resolution to study in vivo hematopoiesis using the murine bone marrow transplant experimental model. Genetic combinatorial marking using lentiviral vectors encoding fluorescent proteins (FPs) enabled cell fate mapping through advanced microscopy imaging. Vectors encoding five different FPs: Cerulean, EGFP, Venus, tdTomato, and mCherry were used to concurrently transduce HSPCs, creating a diverse palette of color marked cells. Imaging using confocal/two-photon hybrid microscopy enables simultaneous high resolution assessment of uniquely marked cells and their progeny in conjunction with structural components of the tissues. Volumetric analyses over large areas reveal that spectrally coded HSPC-derived cells can be detected non-invasively in various intact tissues, including the bone marrow (BM), for extensive periods of time following transplantation. Live studies combining video-rate multiphoton and confocal time-lapse imaging in 4D demonstrate the possibility of dynamic cellular and clonal tracking in a quantitative manner. PMID:25145579
Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir
2015-06-01
The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.
Three-dimensional MRI-linac intra-fraction guidance using multiple orthogonal cine-MRI planes.
Bjerre, Troels; Crijns, Sjoerd; af Rosenschöld, Per Munck; Aznar, Marianne; Specht, Lena; Larsen, Rasmus; Keall, Paul
2013-07-21
The introduction of integrated MRI-radiation therapy systems will offer live intra-fraction imaging. We propose a feasible low-latency multi-plane MRI-linac guidance strategy. In this work we demonstrate how interleaved acquired, orthogonal cine-MRI planes can be used for low-latency tracking of the 3D trajectory of a soft-tissue target structure. The proposed strategy relies on acquiring a pre-treatment 3D breath-hold scan, extracting a 3D target template and performing template matching between this 3D template and pairs of orthogonal 2D cine-MRI planes intersecting the target motion path. For a 60 s free-breathing series of orthogonal cine-MRI planes, we demonstrate that the method was capable of accurately tracking the respiration related 3D motion of the left kidney. Quantitative evaluation of the method using a dataset designed for this purpose revealed a translational error of 1.15 mm for a translation of 39.9 mm. We have demonstrated how interleaved acquired, orthogonal cine-MRI planes can be used for online tracking of soft-tissue target volumes.
Speckle tracking evaluation of right ventricular functions in children with sickle cell disease.
Tolba, Osama Abd Rab Elrasol; El-Shanshory, Mohamed Ramadan; El-Gamasy, Mohamed Abd Elaziz; El-Shehaby, Walid Ahmed
2017-01-01
Cardiac dysfunction is a risk factor for death in patients with sickle cell disease (SCD). Aim of the work is to evaluate the right ventricular systolic and diastolic functions by tissue Doppler and speckling tracking imaging in children with SCD. Thirty children with SCD and thirty controls were subjected to clinical, laboratory evaluations, and echocardiographic study using GE Vivid 7 (GE Medical System, Horten, Norway with a 3.5-MHz multifrequency transducer) including; Two-dimensional and tissue Doppler echocardiographic study (lateral tricuspid valve annulus peak E' velocity, lateral tricuspid valve annulus peak A' velocity, E'/A' ratio, isovolumetric relaxation time, lateral tricuspid valve annulus S' and septal S' waves and peak longitudinal systolic strain [PLSS] and time to PLSS) were done in six right ventricular segments. There was a significant decrease in right ventricular systolic and diastolic function in patients group when compared to controls. Children with SCD have impaired right ventricular systolic and diastolic functions when compared to healthy children with early evaluation of the systolic dysfunction by speckle tracking imaging technique.
Zhou, Xinyi Y; Tay, Zhi Wei; Chandrasekharan, Prashant; Yu, Elaine Y; Hensley, Daniel W; Orendorff, Ryan; Jeffris, Kenneth E; Mai, David; Zheng, Bo; Goodwill, Patrick W; Conolly, Steven M
2018-05-10
Magnetic particle imaging (MPI) is an emerging ionizing radiation-free biomedical tracer imaging technique that directly images the intense magnetization of superparamagnetic iron oxide nanoparticles (SPIOs). MPI offers ideal image contrast because MPI shows zero signal from background tissues. Moreover, there is zero attenuation of the signal with depth in tissue, allowing for imaging deep inside the body quantitatively at any location. Recent work has demonstrated the potential of MPI for robust, sensitive vascular imaging and cell tracking with high contrast and dose-limited sensitivity comparable to nuclear medicine. To foster future applications in MPI, this new biomedical imaging field is welcoming researchers with expertise in imaging physics, magnetic nanoparticle synthesis and functionalization, nanoscale physics, and small animal imaging applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
76 FR 43266 - Marine Mammals; File No. 16472
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-20
... (Lobodon carcinophagus), leopard seals (Hydrurga leptonyx), Ross seals (Ommatophoca rossii), and Weddell... monitoring program established in 1986. The applicant also requests permission to import tissue samples... seals, 100 crabeater seals, 100 leopard seals, 200 Weddell seals, and 5 Ross seals would be taken...
Cancer Genome Anatomy Project | Office of Cancer Genomics
The National Cancer Institute (NCI) Cancer Genome Anatomy Project (CGAP) is an online resource designed to provide the research community access to biological tissue characterization data. Request a free copy of the CGAP Website Virtual Tour CD from ocg@mail.nih.gov.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-16
... summaries of proposed projects to be submitted to the Office of Management and Budget (OMB) for review and... obtain the personal histories to compare to the life styles and exposures and the biospecimens will serve...
An MRI-Compatible Robotic System With Hybrid Tracking for MRI-Guided Prostate Intervention
Krieger, Axel; Iordachita, Iulian I.; Guion, Peter; Singh, Anurag K.; Kaushal, Aradhana; Ménard, Cynthia; Pinto, Peter A.; Camphausen, Kevin; Fichtinger, Gabor
2012-01-01
This paper reports the development, evaluation, and first clinical trials of the access to the prostate tissue (APT) II system—a scanner independent system for magnetic resonance imaging (MRI)-guided transrectal prostate interventions. The system utilizes novel manipulator mechanics employing a steerable needle channel and a novel six degree-of-freedom hybrid tracking method, comprising passive fiducial tracking for initial registration and subsequent incremental motion measurements. Targeting accuracy of the system in prostate phantom experiments and two clinical human-subject procedures is shown to compare favorably with existing systems using passive and active tracking methods. The portable design of the APT II system, using only standard MRI image sequences and minimal custom scanner interfacing, allows the system to be easily used on different MRI scanners. PMID:22009867
Acute Traumatic Tear of Latissimus Dorsi Muscle in an Elite Track Athlete
Çelebi, Mehmet Mesut; Ergen, Emin; Üstüner, Evren
2013-01-01
Soft tissue injuries constitute 30-50% of all sports related injuries; however, injury to the latissimus dorsi muscle is quite rare with only a few cases reported in the literature. Herein, we describe an acute traumatic tear of the latissimus dorsi muscle in an elite track athlete, which has not been reported in the track and field sports before. The injury was caused by forceful resisted arm adduction that took place at hurdling and starting from the block. A pseudotumor appearance in the axillary region was misdiagnosed as a mass. The diagnosis was made by ultrasound alone and the patient was managed conservatively. PMID:24765503
The yield of colorectal cancer among fast track patients with normocytic and microcytic anaemia.
Panagiotopoulou, I G; Fitzrol, D; Parker, R A; Kuzhively, J; Luscombe, N; Wells, A D; Menon, M; Bajwa, F M; Watson, M A
2014-05-01
We receive fast track referrals on the basis of iron deficiency anaemia (IDA) for patients with normocytic anaemia or for patients with no iron studies. This study examined the yield of colorectal cancer (CRC) among fast track patients to ascertain whether awaiting confirmation of IDA is necessary prior to performing bowel investigations. A review was undertaken of 321 and 930 consecutive fast track referrals from Centre A and Centre B respectively. Contingency tables were analysed using Fisher's exact test. Logistic regression analyses were performed to investigate significant predictors of CRC. Overall, 229 patients were included from Centre A and 689 from Centre B. The odds ratio for microcytic anaemia versus normocytic anaemia in the outcome of CRC was 1.3 (95% confidence interval [CI]: 0.5-3.9) for Centre A and 1.6 (95% CI: 0.8-3.3) for Centre B. In a logistic regression analysis (Centre B only), no significant difference in CRC rates was seen between microcytic and normocytic anaemia (adjusted odds ratio: 1.9, 95% CI: 0.9-3.9). There was no statistically significant difference in the yield of CRC between microcytic and normocytic anaemia (p=0.515, Fisher's exact test) in patients with anaemia only and no colorectal symptoms. Finally, CRC cases were seen in both microcytic and normocytic groups with or without low ferritin. There is no significant difference in the yield of CRC between fast track patients with microcytic and normocytic anaemia. This study provides insufficient evidence to support awaiting confirmation of IDA in fast track patients with normocytic anaemia prior to requesting bowel investigations.
An Evaluation Methodology for Longitudinal Studies of Short Term Cancer Research Training Programs
Padilla, Luz A.; Venkatesh, Raam; Daniel, Casey L.; Desmond, Renee A.; Brooks, C. Michael; Waterbor, John W.
2014-01-01
The need to familiarize medical students and graduate health professional students with research training opportunities that cultivate the appeal of research careers is vital to the future of research. Comprehensive evaluation of a cancer research training program can be achieved through longitudinal tracking of program alumni to assess the program’s impact on each participant’s career path and professional achievements. With advances in technology and smarter means of communication, effective ways to track alumni have changed. In order to collect data on the career outcomes and achievements of nearly 500 short-term cancer research training program alumni from 1999–2013, we sought to contact each alumnus to request completion of a survey instrument online, or by means of a telephone interview. The effectiveness of each contact method that we used was quantified according to ease of use and time required. The most reliable source of contact information for tracking alumni from the early years of the program was previous tracking results; and for alumni from the later years, the most important source of contact information was university alumni records that provided email addresses and telephone numbers. Personal contacts with former preceptors were sometimes helpful, as were generic search engines and people search engines. Social networking was of little value for most searches. Using information from two or more sources in combination was most effective in tracking alumni. These results provide insights and tools for other research training programs that wish to track their alumni for long-term program evaluation. PMID:25412722
Frequency of brain tissue donation for research after suicide.
Longaray, Vanessa K; Padoan, Carolina S; Goi, Pedro D; da Fonseca, Rodrigo C; Vieira, Daniel C; Oliveira, Francine H de; Kapczinski, Flávio; Magalhães, Pedro V
2017-01-01
To describe the frequency of brain tissue donation for research purposes by families of individuals that committed suicide. All requests for brain tissue donation to a brain biorepository made to the families of individuals aged 18-60 years who had committed suicide between March 2014 and February 2016 were included. Cases presenting with brain damage due to acute trauma were excluded. Fifty-six cases of suicide were reported. Of these, 24 fulfilled the exclusion criteria, and 11 others were excluded because no next of kin was found to provide informed consent. Of the 21 remaining cases, brain tissue donation was authorized in nine (tissue fragments in seven and the entire organ in two). Donation of brain tissue from suicide cases for research purposes is feasible. The acceptance rate of 42.8% in our sample is in accordance with international data on such donations, and similar to rates reported for neurodegenerative diseases.
Look--but also listen! ReQuest: A new dimension-oriented GERD symptom scale.
Bardhan, Karna Dev
2004-03-01
The symptom spectrum of gastroesophageal reflux disease (GERD) is much wider than is commonly believed, and in about half the patients endoscopic examination is negative. The role of endoscopy to assess response to treatment is therefore much reduced in GERD. Assessment of symptoms is becoming increasingly important, so different outcome measures are required. The Reflux Questionnaire ReQuest was thus designed as a brief, effective and robust method of tracking and quantifying GERD symptoms during treatment. It comprises seven dimensions: general well-being, acid complaints, upper abdominal/stomach complaints, lower abdominal/digestive complaints, nausea, sleep disturbances and other complaints. In the short version of ReQuest the symptom burden of each dimension is measured by its frequency and intensity (except general well-being, for which only the intensity was determined). The long version also includes 67 symptom descriptions that constitute the dimensions (except general well-being). The rigorous validation process included clinical trial evaluation and statistical assessment of the findings. Important measures of the instrument, such as internal consistency, test/ retest reliability, construct validity and the responsiveness to changes during treatment, among others, all fulfilled or exceeded requirements, thereby demonstrating the accuracy of the instrument. ReQuest meets the criteria set by regulatory authorities and serves as the primary outcome measure for symptom assessment in future clinical trials of current and new treatments. (c) 2004 Prous Science
NASA Astrophysics Data System (ADS)
Kubelick, Kelsey; Snider, Eric; Yoon, Heechul; Ethier, C. Ross; Emelianov, Stanislav Y.
2017-03-01
Glaucoma is associated with dysfunction of the trabecular meshwork (TM), a fluid drainage tissue in the anterior eye. A promising treatment involves delivery of stem cells to the TM to restore tissue function. Currently histology is the gold standard for tracking stem cell delivery and differentiation. To expedite clinical translation, non-invasive longitudinal monitoring in vivo is desired. Our current research explores a technique combining ultrasound (US) and photoacoustic (PA) imaging to track mesenchymal stem cells (MSCs) after intraocular injection. Adipose-derived MSCs were incubated with gold nanospheres to label cells (AuNS-MSCs) for PA imaging. Successful labeling was first verified with in vitro phantom studies. Next, MSC delivery was imaged ex vivo in porcine eyes, while intraocular pressure was hydrostatically clamped to maintain a physiological flow rate through the TM. US/PA imaging was performed before, during, and after AuNS-MSC delivery. Additionally, spectroscopic PA imaging was implemented to isolate PA signals from AuNS-MSCs. In vitro cell imaging showed AuNS-MSCs produce strong PA signals, suggesting that MSCs can be tracked using PA imaging. While the cornea, sclera, iris, and TM region can be visualized with US imaging, pigmented tissues also produce PA signals. Both modalities provide valuable anatomical landmarks for MSC localization. During delivery, PA imaging can visualize AuNS-MSC motion and location, creating a unique opportunity to guide ocular cell delivery. Lastly, distinct spectral signatures of AuNS-MSCs allow unmixing, with potential for quantitative PA imaging. In conclusion, results show proof-of-concept for monitoring MSC ocular delivery, raising opportunities for in vivo image-guided cell delivery.
NASA Astrophysics Data System (ADS)
Sadhasivam, Jayakumar; Alamelu, M.; Radhika, R.; Ramya, S.; Dharani, K.; Jayavel, Senthil
2017-11-01
Now a days the people's attraction towards Automated Teller Machine(ATM) has been increasing even in rural areas. As of now the security provided by all the bank is ATM pin number. Hackers know the way to easily identify the pin number and withdraw money if they haven stolen the ATM card. Also, the Automated Teller Machine is broken and the money is stolen. To overcome these disadvantages, we propose an approach “Automated Secure Tracking System” to secure and tracking the changes in ATM. In this approach, while creating the bank account, the bank should scan the iris known (a part or movement of our eye) and fingerprint of the customer. The scanning can be done with the position of the eye movements and fingerprints identified with the shortest measurements. When the card is swiped then ATM should request the pin, scan the iris and recognize the fingerprint and then allow the customer to withdraw money. If somebody tries to break the ATM an alert message is given to the nearby police station and the ATM shutter is automatically closed. This helps in avoiding the hackers who withdraw money by stealing the ATM card and also helps the government in identifying the criminals easily.
Michel, Audrey M; Kiniry, Stephen J; O’Connor, Patrick B F; Mullan, James P
2018-01-01
Abstract The GWIPS-viz browser (http://gwips.ucc.ie/) is an on-line genome browser which is tailored for exploring ribosome profiling (Ribo-seq) data. Since its publication in 2014, GWIPS-viz provides Ribo-seq data for an additional 14 genomes bringing the current total to 23. The integration of new Ribo-seq data has been automated thereby increasing the number of available tracks to 1792, a 10-fold increase in the last three years. The increase is particularly substantial for data derived from human sources. Following user requests, we added the functionality to download these tracks in bigWig format. We also incorporated new types of data (e.g. TCP-seq) as well as auxiliary tracks from other sources that help with the interpretation of Ribo-seq data. Improvements in the visualization of the data have been carried out particularly for bacterial genomes where the Ribo-seq data are now shown in a strand specific manner. For higher eukaryotic datasets, we provide characteristics of individual datasets using the RUST program which includes the triplet periodicity, sequencing biases and relative inferred A-site dwell times. This information can be used for assessing the quality of Ribo-seq datasets. To improve the power of the signal, we aggregate Ribo-seq data from several studies into Global aggregate tracks for each genome. PMID:28977460
Fine spatiotemporal activity in contracting myometrium revealed by motion-corrected calcium imaging.
Loftus, Fiona C; Shmygol, Anatoly; Richardson, Magnus J E
2014-10-15
Successful childbirth depends on the occurrence of precisely coordinated uterine contractions during labour. Calcium indicator fluorescence imaging is one of the main techniques for investigating the mechanisms governing this physiological process and its pathologies. The effective spatiotemporal resolution of calcium signals is, however, limited by the motion of contracting tissue: structures of interest in the order of microns can move over a hundred times their width during a contraction. The simultaneous changes in local intensity and tissue configuration make motion tracking a non-trivial problem in image analysis and confound many of the standard techniques. This paper presents a method that tracks local motion throughout the tissue and allows for the almost complete removal of motion artefacts. This provides a stabilized calcium signal down to a pixel resolution, which, for the data examined, is in the order of a few microns. As a byproduct of image stabilization, a complete kinematic description of the contraction-relaxation cycle is also obtained. This contains novel information about the mechanical response of the tissue, such as the identification of a characteristic length scale, in the order of 40-50 μm, below which tissue motion is homogeneous. Applied to our data, we illustrate that the method allows for analyses of calcium dynamics in contracting myometrium in unprecedented spatiotemporal detail. Additionally, we use the kinematics of tissue motion to compare calcium signals at the subcellular level and local contractile motion. The computer code used is provided in a freely modifiable form and has potential applicability to in vivo calcium imaging of neural tissue, as well as other smooth muscle tissue. © 2014 The Authors. The Journal of Physiology published by John Wiley & Sons Ltd on behalf of The Physiological Society.
Fine spatiotemporal activity in contracting myometrium revealed by motion-corrected calcium imaging
Loftus, Fiona C; Shmygol, Anatoly; Richardson, Magnus J E
2014-01-01
Successful childbirth depends on the occurrence of precisely coordinated uterine contractions during labour. Calcium indicator fluorescence imaging is one of the main techniques for investigating the mechanisms governing this physiological process and its pathologies. The effective spatiotemporal resolution of calcium signals is, however, limited by the motion of contracting tissue: structures of interest in the order of microns can move over a hundred times their width during a contraction. The simultaneous changes in local intensity and tissue configuration make motion tracking a non-trivial problem in image analysis and confound many of the standard techniques. This paper presents a method that tracks local motion throughout the tissue and allows for the almost complete removal of motion artefacts. This provides a stabilized calcium signal down to a pixel resolution, which, for the data examined, is in the order of a few microns. As a byproduct of image stabilization, a complete kinematic description of the contraction–relaxation cycle is also obtained. This contains novel information about the mechanical response of the tissue, such as the identification of a characteristic length scale, in the order of 40–50 μm, below which tissue motion is homogeneous. Applied to our data, we illustrate that the method allows for analyses of calcium dynamics in contracting myometrium in unprecedented spatiotemporal detail. Additionally, we use the kinematics of tissue motion to compare calcium signals at the subcellular level and local contractile motion. The computer code used is provided in a freely modifiable form and has potential applicability to in vivo calcium imaging of neural tissue, as well as other smooth muscle tissue. PMID:25085893
Action at the Horizon: Chandra/EHT Observations of Sgr A*
NASA Astrophysics Data System (ADS)
Neilsen, Joseph
2017-09-01
In April 2017, the Event Horizon Telescope will observe Sgr A* with imaging quality sufficient to resolve the shadow of the black hole, while providing a close-up view of accretion at the horizon. As Sgr A* is a well-known source of X-ray flares, coordinated Chandra/EHT observations offer an incredible opportunity: a chance to observe structures (e.g., hotspots) near the event horizon while tracking their high-energy variability. In anticipation of a follow-up campaign in 2018, we are requesting 4x33 ks Chandra observations of Sgr A* to be coordinated with EHT. This campaign will double our chances of simultaneous flares. We will search for flares and hotspots, provide priors for EHT image reconstruction, and track any activity associated with the closest approach of the massive star S0-2.
Locational Sensitivity Investigation on PV Hosting Capacity and Fast Track PV Screening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Fei; Mather, Barry; Ainsworth, Nathan
A 15% PV penetration threshold is commonly used by utilities to define photovoltaic (PV) screening methods where PV penetration is defined as the ratio of total solar PV capacity on a line section to peak load. However, this method doesn't take into account PV locational impact or feeder characteristics that could strongly change the feeder's capability to host PVs. This paper investigates the impact of PV location and phase connection type on PV hosting capacity, and then proposes a fast-track PV screening approach that leverages various PV hosting capacity metric responding to different PV locations and types. The proposed studymore » could help utilities to evaluate PV interconnection requests and also help increase the PV hosting capacity of distribution feeders without adverse impacts on system voltages.« less
Big differences in primary care celiac disease serological markers request in Spain.
Salinas, Maria; López-Garrigós, Maite; Flores, Emilio; Leiva-Salinas, Carlos
2017-02-15
Celiac disease (CD) prevalence is increasing but the disorder remains undiagnosed. The study compares CD serology markers requested by General Practitioners (GPs) over time and geographical areas. The aim of the current research is to assess the inter-practice and temporal variability in the request of CD serology markers by GPs in Spain, and the differences between regions. A cross-sectional study was conducted enrolling Spanish clinical laboratories. Primary care CD serology markers request in 2010, 2012 and 2014 from 15 autonomous communities (AACC), with more participants was reported. Test-utilization rates were calculated (tissue transglutaminase IgA antibodies (tTG-IgA) and deaminated peptide gliadine IgA antibodies (DGP-IgA) per 1000 inhabitants), and also the ratio of both tests request (DGP-IgA /tTG-IgA). The request of tTG-IgA per 1000 inhabitants increased significantly along years (from 3.99 to 5.90 (P < 0.001)). The demand of DGP-IgA per 1000 inhabitants was maintained in 2010 and 2012 (0.68 and 0.6), and decreased in 2014 (0.35) (P = 0.927). DGP-IgA /tTG-IgA diminished over time (from 0.16 to 0.06 (P = 0.548)), and in the 2014 edition, there was a significant regional difference, ranging from 0.01 to 0.57 (P < 0.001). The variability in the request in CD serology markers emphasizes the need of inter-regional cooperation to develop strategies to optimize the use of laboratory tests.
Shear wave elasticity imaging based on acoustic radiation force and optical detection.
Cheng, Yi; Li, Rui; Li, Sinan; Dunsby, Christopher; Eckersley, Robert J; Elson, Daniel S; Tang, Meng-Xing
2012-09-01
Tissue elasticity is closely related to the velocity of shear waves within biologic tissue. Shear waves can be generated by an acoustic radiation force and tracked by, e.g., ultrasound or magnetic resonance imaging (MRI) measurements. This has been shown to be able to noninvasively map tissue elasticity in depth and has great potential in a wide range of clinical applications including cancer and cardiovascular diseases. In this study, a highly sensitive optical measurement technique is proposed as an alternative way to track shear waves generated by the acoustic radiation force. A charge coupled device (CCD) camera was used to capture diffuse photons from tissue mimicking phantoms illuminated by a laser source at 532 nm. CCD images were recorded at different delays after the transmission of an ultrasound burst and were processed to obtain the time of flight for the shear wave. A differential measurement scheme involving generation of shear waves at two different positions was used to improve the accuracy and spatial resolution of the system. The results from measurements on both homogeneous and heterogeneous phantoms were compared with measurements from other instruments and demonstrate the feasibility and accuracy of the technique for imaging and quantifying elasticity. The relative error in estimation of shear wave velocity can be as low as 3.3% with a spatial resolution of 2 mm, and increases to 8.8% with a spatial resolution of 1 mm for the medium stiffness phantom. The system is shown to be highly sensitive and is able to track shear waves propagating over several centimetres given the ultrasound excitation amplitude and the phantom material used in this study. It was also found that the reflection of shear waves from boundaries between regions with different elastic properties can cause significant bias in the estimation of elasticity, which also applies to other shear wave tracking techniques. This bias can be reduced at the expense of reduced spatial resolution. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
76 FR 10558 - Notice of Scope Rulings
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-25
... People's Republic of China. Requestor: Blackstone OTR LLC and OTR Wheel Engineering, Inc.; whether...-601: Tapered Roller Bearings from the People's Republic of China. Requestor: New Trend Engineering... antidumping duty order; requested February 17, 2010; initiated April 16, 2010. A-570-894: Certain Tissue Paper...
Accuracy of lesion boundary tracking in navigated breast tumor excision
NASA Astrophysics Data System (ADS)
Heffernan, Emily; Ungi, Tamas; Vaughan, Thomas; Pezeshki, Padina; Lasso, Andras; Gauvin, Gabrielle; Rudan, John; Engel, C. Jay; Morin, Evelyn; Fichtinger, Gabor
2016-03-01
PURPOSE: An electromagnetic navigation system for tumor excision in breast conserving surgery has recently been developed. Preoperatively, a hooked needle is positioned in the tumor and the tumor boundaries are defined in the needle coordinate system. The needle is tracked electromagnetically throughout the procedure to localize the tumor. However, the needle may move and the tissue may deform, leading to errors in maintaining a correct excision boundary. It is imperative to quantify these errors so the surgeon can choose an appropriate resection margin. METHODS: A commercial breast biopsy phantom with several inclusions was used. Location and shape of a lesion before and after mechanical deformation were determined using 3D ultrasound volumes. Tumor location and shape were estimated from initial contours and tracking data. The difference in estimated and actual location and shape of the lesion after deformation was quantified using the Hausdorff distance. Data collection and analysis were done using our 3D Slicer software application and PLUS toolkit. RESULTS: The deformation of the breast resulted in 3.72 mm (STD 0.67 mm) average boundary displacement for an isoelastic lesion and 3.88 mm (STD 0.43 mm) for a hyperelastic lesion. The difference between the actual and estimated tracked tumor boundary was 0.88 mm (STD 0.20 mm) for the isoelastic and 1.78 mm (STD 0.18 mm) for the hyperelastic lesion. CONCLUSION: The average lesion boundary tracking error was below 2mm, which is clinically acceptable. We suspect that stiffness of the phantom tissue affected the error measurements. Results will be validated in patient studies.
The impact of cine EPID image acquisition frame rate on markerless soft-tissue tracking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yip, Stephen, E-mail: syip@lroc.harvard.edu; Rottmann, Joerg; Berbeco, Ross
2014-06-15
Purpose: Although reduction of the cine electronic portal imaging device (EPID) acquisition frame rate through multiple frame averaging may reduce hardware memory burden and decrease image noise, it can hinder the continuity of soft-tissue motion leading to poor autotracking results. The impact of motion blurring and image noise on the tracking performance was investigated. Methods: Phantom and patient images were acquired at a frame rate of 12.87 Hz with an amorphous silicon portal imager (AS1000, Varian Medical Systems, Palo Alto, CA). The maximum frame rate of 12.87 Hz is imposed by the EPID. Low frame rate images were obtained bymore » continuous frame averaging. A previously validated tracking algorithm was employed for autotracking. The difference between the programmed and autotracked positions of a Las Vegas phantom moving in the superior-inferior direction defined the tracking error (δ). Motion blurring was assessed by measuring the area change of the circle with the greatest depth. Additionally, lung tumors on 1747 frames acquired at 11 field angles from four radiotherapy patients are manually and automatically tracked with varying frame averaging. δ was defined by the position difference of the two tracking methods. Image noise was defined as the standard deviation of the background intensity. Motion blurring and image noise are correlated with δ using Pearson correlation coefficient (R). Results: For both phantom and patient studies, the autotracking errors increased at frame rates lower than 4.29 Hz. Above 4.29 Hz, changes in errors were negligible withδ < 1.60 mm. Motion blurring and image noise were observed to increase and decrease with frame averaging, respectively. Motion blurring and tracking errors were significantly correlated for the phantom (R = 0.94) and patient studies (R = 0.72). Moderate to poor correlation was found between image noise and tracking error with R −0.58 and −0.19 for both studies, respectively. Conclusions: Cine EPID image acquisition at the frame rate of at least 4.29 Hz is recommended. Motion blurring in the images with frame rates below 4.29 Hz can significantly reduce the accuracy of autotracking.« less
Non-invasive Assessments of Adipose Tissue Metabolism In Vitro.
Abbott, Rosalyn D; Borowsky, Francis E; Quinn, Kyle P; Bernstein, David L; Georgakoudi, Irene; Kaplan, David L
2016-03-01
Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with non-invasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored.
Non-invasive assessments of adipose tissue metabolism in vitro
Abbott, Rosalyn D.; Borowsky, Francis E.; Quinn, Kyle P.; Bernstein, David L.; Georgakoudi, Irene; Kaplan, David L.
2015-01-01
Adipose tissue engineering is a diverse area of research where the developed tissues can be used to study normal adipose tissue functions, create disease models in vitro, and replace soft tissue defects in vivo. Increasing attention has been focused on the highly specialized metabolic pathways that regulate energy storage and release in adipose tissues which affect local and systemic outcomes. Non-invasive, dynamic measurement systems are useful to track these metabolic pathways in the same tissue model over time to evaluate long term cell growth, differentiation, and development within tissue engineering constructs. This approach reduces costs and time in comparison to more traditional destructive methods such as biochemical and immunochemistry assays and proteomics assessments. Towards this goal, this review will focus on important metabolic functions of adipose tissues and strategies to evaluate them with noninvasive in vitro methods. Current non-invasive methods, such as measuring key metabolic markers and endogenous contrast imaging will be explored. PMID:26399988
HCE Research Coordination Directorate (ReCoorD Database)
2016-04-27
portfolio management is often hidden within broader mission scopes and visibility into those portfolio is often limited at best. Current specialty...specific tracking databases do not exist. Current broad-sweeping portfolio management tools do not exist (not true--define terms?). The HCE receives...requests from a variety of oversight bodies for reports on the current state of project-through- portfolio efforts. Tools such as NIH’s Reporter, while still in development, do not yet appear to meet HCE element requirements.
When do doctors follow patients' orders? Organizational mechanisms of physician influence.
Menchik, Daniel A; Jin, Lei
2014-11-01
Physicians, like other professionals, are expected to draw from specialized knowledge while remaining receptive to clients' requests. Using nationally representative U.S. survey data from the Community Tracking Study, this paper examines the degree to which physicians are influenced by patients' requests, and how physicians' workplaces may mediate acquiescence rates through three mechanisms: constraints, protection, and incentives. We find that, based on physicians' reports of their responses to patients' suggestions, patient influence is rare. This influence is least likely to be felt in large workplaces, such as large private practices, hospitals, and medical schools. We find that the protection and incentives mechanisms mediate the relationship between workplace types and physician acquiescence but more prescriptive measures such as guidelines and formularies do not affect acquiescence. We discuss these findings in light of the ongoing changes in the structure of medicine. Copyright © 2014 Elsevier Inc. All rights reserved.
The social-cognitive basis of infants' reference to absent entities.
Bohn, Manuel; Zimmermann, Luise; Call, Josep; Tomasello, Michael
2018-04-06
Recent evidence suggests that infants as young as 12 month of age use pointing to communicate about absent entities. The tacit assumption underlying these studies is that infants do so based on tracking what their interlocutor experienced in a previous shared interaction. The present study addresses this assumption empirically. In three experiments, 12-month-old infants could request additional desired objects by pointing to the location in which these objects were previously located. We systematically varied whether the adult from whom infants were requesting had previously experienced the former content of the location with the infant. Infants systematically adjusted their pointing to the now empty location to what they experienced with the adult previously. These results suggest that infants' ability to communicate about absent referents is based on an incipient form of common ground. Copyright © 2018 Elsevier B.V. All rights reserved.
Feature tracking for automated volume of interest stabilization on 4D-OCT images
NASA Astrophysics Data System (ADS)
Laves, Max-Heinrich; Schoob, Andreas; Kahrs, Lüder A.; Pfeiffer, Tom; Huber, Robert; Ortmaier, Tobias
2017-03-01
A common representation of volumetric medical image data is the triplanar view (TV), in which the surgeon manually selects slices showing the anatomical structure of interest. In addition to common medical imaging such as MRI or computed tomography, recent advances in the field of optical coherence tomography (OCT) have enabled live processing and volumetric rendering of four-dimensional images of the human body. Due to the region of interest undergoing motion, it is challenging for the surgeon to simultaneously keep track of an object by continuously adjusting the TV to desired slices. To select these slices in subsequent frames automatically, it is necessary to track movements of the volume of interest (VOI). This has not been addressed with respect to 4DOCT images yet. Therefore, this paper evaluates motion tracking by applying state-of-the-art tracking schemes on maximum intensity projections (MIP) of 4D-OCT images. Estimated VOI location is used to conveniently show corresponding slices and to improve the MIPs by calculating thin-slab MIPs. Tracking performances are evaluated on an in-vivo sequence of human skin, captured at 26 volumes per second. Among investigated tracking schemes, our recently presented tracking scheme for soft tissue motion provides highest accuracy with an error of under 2.2 voxels for the first 80 volumes. Object tracking on 4D-OCT images enables its use for sub-epithelial tracking of microvessels for image-guidance.
Stable microwave radiometry system for long term monitoring of deep tissue temperature
NASA Astrophysics Data System (ADS)
Stauffer, Paul R.; Rodriques, Dario B.; Salahi, Sara; Topsakal, Erdem; Oliveira, Tiago R.; Prakash, Aniruddh; D'Isidoro, Fabio; Reudink, Douglas; Snow, Brent W.; Maccarini, Paolo F.
2013-02-01
Background: There are numerous clinical applications for non-invasive monitoring of deep tissue temperature. We present the design and experimental performance of a miniature radiometric thermometry system for measuring volume average temperature of tissue regions located up to 5cm deep in the body. Methods: We constructed a miniature sensor consisting of EMI-shielded log spiral microstrip antenna with high gain onaxis and integrated high-sensitivity 1.35GHz total power radiometer with 500 MHz bandwidth. We tested performance of the radiometry system in both simulated and experimental multilayer phantom models of several intended clinical measurement sites: i) brown adipose tissue (BAT) depots within 2cm of the skin surface, ii) 3-5cm deep kidney, and iii) human brain underlying intact scalp and skull. The physical models included layers of circulating tissue-mimicking liquids controlled at different temperatures to characterize our ability to quantify small changes in target temperature at depth under normothermic surface tissues. Results: We report SAR patterns that characterize the sense region of a 2.6cm diameter receive antenna, and radiometric power measurements as a function of deep tissue temperature that quantify radiometer sensitivity. The data demonstrate: i) our ability to accurately track temperature rise in realistic tissue targets such as urine refluxed from prewarmed bladder into kidney, and 10°C drop in brain temperature underlying normothermic scalp and skull, and ii) long term accuracy and stability of +0.4°C over 4.5 hours as needed for monitoring core body temperature over extended surgery or monitoring effects of brown fat metabolism over an extended sleep/wake cycle. Conclusions: A non-invasive sensor consisting of 2.6cm diameter receive antenna and integral 1.35GHz total power radiometer has demonstrated sufficient sensitivity to track clinically significant changes in temperature of deep tissue targets underlying normothermic surface tissues for clinical applications like the detection of vesicoureteral reflux, and long term monitoring of brown fat metabolism or brain core temperature during extended surgery.
Stable Microwave Radiometry System for Long Term Monitoring of Deep Tissue Temperature.
Stauffer, Paul R; Rodriques, Dario B; Salahi, Sara; Topsakal, Erdem; Oliveira, Tiago R; Prakash, Aniruddh; D'Isidoro, Fabio; Reudink, Douglas; Snow, Brent W; Maccarini, Paolo F
2013-02-26
There are numerous clinical applications for non-invasive monitoring of deep tissue temperature. We present the design and experimental performance of a miniature radiometric thermometry system for measuring volume average temperature of tissue regions located up to 5cm deep in the body. We constructed a miniature sensor consisting of EMI-shielded log spiral microstrip antenna with high gain on-axis and integrated high-sensitivity 1.35GHz total power radiometer with 500 MHz bandwidth. We tested performance of the radiometry system in both simulated and experimental multilayer phantom models of several intended clinical measurement sites: i) brown adipose tissue (BAT) depots within 2cm of the skin surface, ii) 3-5cm deep kidney, and iii) human brain underlying intact scalp and skull. The physical models included layers of circulating tissue-mimicking liquids controlled at different temperatures to characterize our ability to quantify small changes in target temperature at depth under normothermic surface tissues. We report SAR patterns that characterize the sense region of a 2.6cm diameter receive antenna, and radiometric power measurements as a function of deep tissue temperature that quantify radiometer sensitivity. The data demonstrate: i) our ability to accurately track temperature rise in realistic tissue targets such as urine refluxed from prewarmed bladder into kidney, and 10°C drop in brain temperature underlying normothermic scalp and skull, and ii) long term accuracy and stability of ∓0.4°C over 4.5 hours as needed for monitoring core body temperature over extended surgery or monitoring effects of brown fat metabolism over an extended sleep/wake cycle. A non-invasive sensor consisting of 2.6cm diameter receive antenna and integral 1.35GHz total power radiometer has demonstrated sufficient sensitivity to track clinically significant changes in temperature of deep tissue targets underlying normothermic surface tissues for clinical applications like the detection of vesicoureteral reflux, and long term monitoring of brown fat metabolism or brain core temperature during extended surgery.
Features and impacts of five multidisciplinary community-university research partnerships.
King, Gillian; Servais, Michelle; Forchuk, Cheryl; Chalmers, Heather; Currie, Melissa; Law, Mary; Specht, Jacqueline; Rosenbaum, Peter; Willoughby, Teena; Kertoy, Marilyn
2010-01-01
Despite the increasing number of multidisciplinary community-university research partnerships designed to address real-world issues, little is known about their nature. This article describes the features and impacts of five research partnerships addressing health or social service issues, which constituted a convenience sample from the province of Ontario, Canada. The article describes their characteristics, ways of operating, outputs, types of requests received from community members and mid-term impacts. Requests directed to partnerships were tracked over a 10-month period in 2003 to 2004, using a research contact checklist, and 174 community members later completed an impact questionnaire capturing perceptions of the impacts of the partnerships on personal knowledge and research skill development, organisational/group access to and use of information, and community and organisational development. The data indicated that partnerships had similar priorities and magnitudes of mid-term impacts, yet differed in the scope of their partnering, realm of intended influence and the number of mechanisms used to engage and communicate with target audiences. The partnerships produced different types of outputs and received different types of requests from community members. The findings inform researchers about partnership diversity and help to establish more realistic expectations about the magnitude of partnerships' impacts.
75 FR 52311 - Notice of Scope Rulings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-25
... Republic of China. Requestor: New Trend Engineering Ltd.; whether its certain wheel hub assemblies are... Bearings from the People's Republic of China. Requestor: Blackstone OTR LLC and OTR Wheel Engineering, Inc... duty order; requested February 17, 2010. A-570-894: Certain Tissue Paper Products from the People's...
A parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging.
Jiang, J; Hall, T J
2007-07-07
Ultrasound-based mechanical strain imaging systems utilize signals from conventional diagnostic ultrasound systems to image tissue elasticity contrast that provides new diagnostically valuable information. Previous works (Hall et al 2003 Ultrasound Med. Biol. 29 427, Zhu and Hall 2002 Ultrason. Imaging 24 161) demonstrated that uniaxial deformation with minimal elevation motion is preferred for breast strain imaging and real-time strain image feedback to operators is important to accomplish this goal. The work reported here enhances the real-time speckle tracking algorithm with two significant modifications. One fundamental change is that the proposed algorithm is a column-based algorithm (a column is defined by a line of data parallel to the ultrasound beam direction, i.e. an A-line), as opposed to a row-based algorithm (a row is defined by a line of data perpendicular to the ultrasound beam direction). Then, displacement estimates from its adjacent columns provide good guidance for motion tracking in a significantly reduced search region to reduce computational cost. Consequently, the process of displacement estimation can be naturally split into at least two separated tasks, computed in parallel, propagating outward from the center of the region of interest (ROI). The proposed algorithm has been implemented and optimized in a Windows system as a stand-alone ANSI C++ program. Results of preliminary tests, using numerical and tissue-mimicking phantoms, and in vivo tissue data, suggest that high contrast strain images can be consistently obtained with frame rates (10 frames s(-1)) that exceed our previous methods.
Dempsey, William P.; Fraser, Scott E.; Pantazis, Periklis
2012-01-01
Background Elucidating the complex cell dynamics (divisions, movement, morphological changes, etc.) underlying embryonic development and adult tissue regeneration requires an efficient means to track cells with high fidelity in space and time. To satisfy this criterion, we developed a transgenic zebrafish line, called PhOTO, that allows photoconvertible optical tracking of nuclear and membrane dynamics in vivo. Methodology PhOTO zebrafish ubiquitously express targeted blue fluorescent protein (FP) Cerulean and photoconvertible FP Dendra2 fusions, allowing for instantaneous, precise targeting and tracking of any number of cells using Dendra2 photoconversion while simultaneously monitoring global cell behavior and morphology. Expression persists through adulthood, making the PhOTO zebrafish an excellent tool for studying tissue regeneration: after tail fin amputation and photoconversion of a ∼100µm stripe along the cut area, marked differences seen in how cells contribute to the new tissue give detailed insight into the dynamic process of regeneration. Photoconverted cells that contributed to the regenerate were separated into three distinct populations corresponding to the extent of cell division 7 days after amputation, and a subset of cells that divided the least were organized into an evenly spaced, linear orientation along the length of the newly regenerating fin. Conclusions/Significance PhOTO zebrafish have wide applicability for lineage tracing at the systems-level in the early embryo as well as in the adult, making them ideal candidate tools for future research in development, traumatic injury and regeneration, cancer progression, and stem cell behavior. PMID:22431986
NASA Astrophysics Data System (ADS)
Szegedi, M.; Rassiah-Szegedi, P.; Fullerton, G.; Wang, B.; Salter, B.
2010-07-01
The purpose of this study is to design a real-tissue phantom for use in the validation of deformation algorithms. A phantom motion controller that runs sinusoidal and non-regular patient-based breathing pattern, via a piston, was applied to porcine liver tissue. It was regulated to simulate movement ranges similar to recorded implanted liver markers from patients. 4D CT was applied to analyze deformation. The suitability of various markers in the liver and the position reproducibility of markers and of reference points were studied. The similarity of marker motion pattern in the liver phantom and in real patients was evaluated. The viability of the phantom over time and its use with electro-magnetic tracking devices were also assessed. High contrast markers, such as carbon markers, implanted in the porcine liver produced less image artifacts on CT and were well visualized compared to metallic ones. The repositionability of markers was within a measurement accuracy of ±2 mm. Similar anatomical patient motions were reproducible up to elongations of 3 cm for a time period of at least 90 min. The phantom is compatible with electro-magnetic tracking devices and 4D CT. The phantom motion is reproducible and simulates realistic patient motion and deformation. The ability to carry out voxel-based tracking allows for the evaluation of deformation algorithms in a controlled environment with recorded patient traces. The phantom is compatible with all therapy devices clinically encountered in our department.
Space Radiation Program Element Tissue Sharing Forum
NASA Technical Reports Server (NTRS)
Wu, H.; Mayeaux, B M.; Huff, J. L.; Simonsen, L. C.
2016-01-01
Over the years, a large number of animal experiments have been conducted at the NASA Space Radiation Laboratory and other facilities under the support of the NASA Space Radiation Program Element (SRPE). Studies using rodents and other animal species to address the space radiation risks will remain a significant portion of the research portfolio of the Element. In order to maximize scientific return of the animal studies, the SRPE has recently released the Space Radiation Tissue Sharing Forum. The Forum provides access to an inventory of investigator-stored tissue samples and enables both NASA SRPE members and NASA-funded investigators to exchange information regarding stored and future radiobiological tissues available for sharing. Registered users may review online data of available tissues, inquire about tissues posted, or request tissues for an upcoming study using an online form. Investigators who have upcoming sacrifices are also encouraged to post the availability of samples using the discussion forum. A brief demo of the forum will be given during the presentation
Harmonic motion detection in a vibrating scattering medium.
Urban, Matthew W; Chen, Shigao; Greenleaf, James
2008-09-01
Elasticity imaging is an emerging medical imaging modality that seeks to map the spatial distribution of tissue stiffness. Ultrasound radiation force excitation and motion tracking using pulse-echo ultrasound have been used in numerous methods. Dynamic radiation force is used in vibrometry to cause an object or tissue to vibrate, and the vibration amplitude and phase can be measured with exceptional accuracy. This paper presents a model that simulates harmonic motion detection in a vibrating scattering medium incorporating 3-D beam shapes for radiation force excitation and motion tracking. A parameterized analysis using this model provides a platform to optimize motion detection for vibrometry applications in tissue. An experimental method that produces a multifrequency radiation force is also presented. Experimental harmonic motion detection of simultaneous multifrequency vibration is demonstrated using a single transducer. This method can accurately detect motion with displacement amplitude as low as 100 to 200 nm in bovine muscle. Vibration phase can be measured within 10 degrees or less. The experimental results validate the conclusions observed from the model and show multifrequency vibration induction and measurements can be performed simultaneously.
Yoshihara, Kazuki; Takagi, Kohei; Son, Aoi; Kurihara, Ryohsuke; Tanabe, Kazuhito
2017-08-17
The use of DNA aggregates could be a promising strategy for the molecular imaging of biological functions. Herein, phosphorescent oligodeoxynucleotides were designed with the aim of visualizing oxygen fluctuation in tumor cells. DNA-ruthenium conjugates (DRCs) that consisted of oligodeoxynucleotides, a phosphorescent ruthenium complex, a pyrene unit for high oxygen responsiveness, and a nitroimidazole unit as a tumor-targeting unit were prepared. In general, oligonucleotides have low cell permeability because of their own negative charges; however, the DRC formed aggregates in aqueous solution due to the hydrophobic pyrene and nitroimidazole groups, and smoothly penetrated the cellular membrane to accumulate in tumor cells in a hypoxia-selective manner. The oxygen-dependent phosphorescence of DRC in cells was also observed. In vivo experiments revealed that aggregates of DRC accumulated in hypoxic tumor tissue that was transplanted into the left leg of mice, and showed that oxygen fluctuations in tumor tissue could be monitored by tracking of the phosphorescence emission of DRC. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Harmonic Motion Detection in a Vibrating Scattering Medium
Urban, Matthew W.; Chen, Shigao; Greenleaf, James F.
2008-01-01
Elasticity imaging is an emerging medical imaging modality that seeks to map the spatial distribution of tissue stiffness. Ultrasound radiation force excitation and motion tracking using pulse-echo ultrasound have been used in numerous methods. Dynamic radiation force is used in vibrometry to cause an object or tissue to vibrate, and the vibration amplitude and phase can be measured with exceptional accuracy. This paper presents a model that simulates harmonic motion detection in a vibrating scattering medium incorporating 3-D beam shapes for radiation force excitation and motion tracking. A parameterized analysis using this model provides a platform to optimize motion detection for vibrometry applications in tissue. An experimental method that produces a multifrequency radiation force is also presented. Experimental harmonic motion detection of simultaneous multifrequency vibration is demonstrated using a single transducer. This method can accurately detect motion with displacement amplitude as low as 100 to 200 nm in bovine muscle. Vibration phase can be measured within 10° or less. The experimental results validate the conclusions observed from the model and show multifrequency vibration induction and measurements can be performed simultaneously. PMID:18986892
Track structure in biological models.
Curtis, S B
1986-01-01
High-energy heavy ions in the galactic cosmic radiation (HZE particles) may pose a special risk during long term manned space flights outside the sheltering confines of the earth's geomagnetic field. These particles are highly ionizing, and they and their nuclear secondaries can penetrate many centimeters of body tissue. The three dimensional patterns of ionizations they create as they lose energy are referred to as their track structure. Several models of biological action on mammalian cells attempt to treat track structure or related quantities in their formulation. The methods by which they do this are reviewed. The proximity function is introduced in connection with the theory of Dual Radiation Action (DRA). The ion-gamma kill (IGK) model introduces the radial energy-density distribution, which is a smooth function characterizing both the magnitude and extension of a charged particle track. The lethal, potentially lethal (LPL) model introduces lambda, the mean distance between relevant ion clusters or biochemical species along the track. Since very localized energy depositions (within approximately 10 nm) are emphasized, the proximity function as defined in the DRA model is not of utility in characterizing track structure in the LPL formulation.
Quantitative semi-automated analysis of morphogenesis with single-cell resolution in complex embryos
Giurumescu, Claudiu A.; Kang, Sukryool; Planchon, Thomas A.; Betzig, Eric; Bloomekatz, Joshua; Yelon, Deborah; Cosman, Pamela; Chisholm, Andrew D.
2012-01-01
A quantitative understanding of tissue morphogenesis requires description of the movements of individual cells in space and over time. In transparent embryos, such as C. elegans, fluorescently labeled nuclei can be imaged in three-dimensional time-lapse (4D) movies and automatically tracked through early cleavage divisions up to ~350 nuclei. A similar analysis of later stages of C. elegans development has been challenging owing to the increased error rates of automated tracking of large numbers of densely packed nuclei. We present Nucleitracker4D, a freely available software solution for tracking nuclei in complex embryos that integrates automated tracking of nuclei in local searches with manual curation. Using these methods, we have been able to track >99% of all nuclei generated in the C. elegans embryo. Our analysis reveals that ventral enclosure of the epidermis is accompanied by complex coordinated migration of the neuronal substrate. We can efficiently track large numbers of migrating nuclei in 4D movies of zebrafish cardiac morphogenesis, suggesting that this approach is generally useful in situations in which the number, packing or dynamics of nuclei present challenges for automated tracking. PMID:23052905
Menten, Martin J; Fast, Martin F; Nill, Simeon; Oelfke, Uwe
2015-12-01
Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Regular dual-energy imaging was able to increase tracking accuracy in left-right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menten, Martin J., E-mail: martin.menten@icr.ac.uk; Fast, Martin F.; Nill, Simeon
2015-12-15
Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated bymore » weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.« less
Proton Radiography With Timepix Based Time Projection Chambers.
Biegun, Aleksandra K; Visser, Jan; Klaver, Tom; Ghazanfari, Nafiseh; van Goethem, Marc-Jan; Koffeman, Els; van Beuzekom, Martin; Brandenburg, Sytze
2016-04-01
The development of a proton radiography system to improve the imaging of patients in proton beam therapy is described. The system comprises gridpix based time projection chambers, which are based on the Timepix chip designed by the Medipix collaboration, for tracking the protons. This type of detector was chosen to have minimal impact on the actual determination of the proton tracks by the tracking detectors. To determine the residual energy of the protons, a BaF 2 crystal with a photomultiplier tube is used. We present data taken in a feasibility experiment with phantoms that represent tissue equivalent materials found in the human body. The obtained experimental results show a good agreement with the performed simulations.
Enhancing regenerative approaches with nanoparticles
Habibovic, Pamela
2017-01-01
In this review, we discuss recent developments in the field of nanoparticles and their use in tissue regeneration approaches. Owing to their unique chemical properties and flexibility in design, nanoparticles can be used as drug delivery systems, to create novel features within materials or as bioimaging agents, or indeed these properties can be combined to create smart multifunctional structures. This review aims to provide an overview of this research field where the focus will be on nanoparticle-based strategies to stimulate bone regeneration; however, the same principles can be applied for other tissue and organ regeneration strategies. In the first section, nanoparticle-based methods for the delivery of drugs, growth factors and genetic material to promote tissue regeneration are discussed. The second section deals with the addition of nanoparticles to materials to create nanocomposites. Such materials can improve several material properties, including mechanical stability, biocompatibility and biological activity. The third section will deal with the emergence of a relatively new field of research using nanoparticles in advanced cell imaging and stem cell tracking approaches. As the development of nanoparticles continues, incorporation of this technology in the field of regenerative medicine will ultimately lead to new tools that can diagnose, track and stimulate the growth of new tissues and organs. PMID:28404870
Enhancing regenerative approaches with nanoparticles.
van Rijt, Sabine; Habibovic, Pamela
2017-04-01
In this review, we discuss recent developments in the field of nanoparticles and their use in tissue regeneration approaches. Owing to their unique chemical properties and flexibility in design, nanoparticles can be used as drug delivery systems, to create novel features within materials or as bioimaging agents, or indeed these properties can be combined to create smart multifunctional structures. This review aims to provide an overview of this research field where the focus will be on nanoparticle-based strategies to stimulate bone regeneration; however, the same principles can be applied for other tissue and organ regeneration strategies. In the first section, nanoparticle-based methods for the delivery of drugs, growth factors and genetic material to promote tissue regeneration are discussed. The second section deals with the addition of nanoparticles to materials to create nanocomposites. Such materials can improve several material properties, including mechanical stability, biocompatibility and biological activity. The third section will deal with the emergence of a relatively new field of research using nanoparticles in advanced cell imaging and stem cell tracking approaches. As the development of nanoparticles continues, incorporation of this technology in the field of regenerative medicine will ultimately lead to new tools that can diagnose, track and stimulate the growth of new tissues and organs. © 2017 The Author(s).
Grizzle, William E; Bell, Walter C; Sexton, Katherine C
2010-01-01
The availability of human tissues to support biomedical research is critical to advance translational research focused on identifying and characterizing approaches to individualized (personalized) medical care. Providing such tissues relies on three acceptable models - a tissue banking model, a prospective collection model and a combination of these two models. An unacceptable model is the "catch as catch can" model in which tissues are collected, processed and stored without goals or a plan or without standard operating procedures, i.e., portions of tissues are collected as available and processed and stored when time permits. In the tissue banking model, aliquots of tissues are collected according to SOPs. Usually specific sizes and types of tissues are collected and processed (e.g., 0.1 gm of breast cancer frozen in OCT). Using the banking model, tissues may be collected that may not be used and/or do not meet specific needs of investigators; however, at the time of an investigator request, tissues are readily available as is clinical information including clinical outcomes. In the model of prospective collection, tissues are collected based upon investigator requests including specific requirements of investigators. For example, the investigator may request that two 0.15 gm matching aliquots of breast cancer be minced while fresh, put in RPMI media with and without fetal calf serum, cooled to 4°C and shipped to the investigator on wet ice. Thus, the tissues collected prospectively meet investigator needs, all collected specimens are utilized and storage of specimens is minimized; however, investigators must wait until specimens are collected, and if needed, for clinical outcome. The operation of any tissue repository requires well trained and dedicated personnel. A quality assurance program is required which provides quality control information on the diagnosis of a specimen that is matched specifically to the specimen provided to an investigator instead of an overall diagnosis of the specimen via a surgical pathology report. This is necessary because a specific specimen may not match the diagnosis of the case due to many factors such as necrosis, unsuspected tumor invasion of apparently normal tissue, and areas of fibrosis which are mistaken grossly for tumor. Aliquots for quality control (QC) may or may not be collected at the time of collection and in some cases, QC may not occur until specimens are distributed to investigators. In establishing a tumor repository, multiple issues need to be considered. These include the available resources, long term support, space and equipment. The needs of the potential users need to be identified as to the types of tissues and services needed and the annotation expected. Other specific issues to be considered include collection of specimens potentially infected with blood borne pathogens (e.g., hepatitis B), charge back mechanisms, informatics needs and support, and investigator requirements (e.g., recognition of repository contributions in publications). In general, the repository should not perform the research of the investigators, but should provide the infrastructure necessary to support the research of the investigator. Thus, the goals of the repository must be established. Similarly, ethical and regulatory issues must be evaluated. In general, tissue repositories need ethical (e.g., IRB) and privacy (e.g., HIPAA) review. Also, safety issues need to be considered as well as how biohazards will be addressed by investigator-users. Considerations involving the transfer of specimens to other organization usually require a material transfer agreement (MTA). A MTA should address biohazards as well as indemnification. Thus, many issues must be considered and addressed in order to establish and operate successfully a biorepository.
The use of donor scleral patch in ophthalmic surgery.
Hodge, Christopher; Sutton, Gerard; Devasahayam, Raj; Georges, Pierre; Treloggen, Jane; Cooper, Simon; Petsoglou, Con
2017-03-01
Scleral tissue has been in use in ophthalmology for many years although indications for use have varied. We retrospectively reviewed scleral transplant tissue requests over a 12 month period at a local eye bank and confirmed a small but significant demand for the use of scleral tissue. Iatrogenic surgical complications are the primary indication for use. Our understanding of the indications and outcomes of scleral graft procedures is derived from case reports and small cohort series. We reviewed the current literature on existing indications for its use and discuss the relative outcomes. To our knowledge this represents the first review of scleral transplant indications and further summarises usage rates in the Lions NSW Eye Bank which may provide practical information for those surgeons who use scleral tissue and Eye Banks who supply it.
NASA Astrophysics Data System (ADS)
Perillo, Evan P.; Liu, Yen-Liang; Huynh, Khang; Liu, Cong; Chou, Chao-Kai; Hung, Mien-Chie; Yeh, Hsin-Chih; Dunn, Andrew K.
2015-07-01
Molecular trafficking within cells, tissues and engineered three-dimensional multicellular models is critical to the understanding of the development and treatment of various diseases including cancer. However, current tracking methods are either confined to two dimensions or limited to an interrogation depth of ~15 μm. Here we present a three-dimensional tracking method capable of quantifying rapid molecular transport dynamics in highly scattering environments at depths up to 200 μm. The system has a response time of 1 ms with a temporal resolution down to 50 μs in high signal-to-noise conditions, and a spatial localization precision as good as 35 nm. Built on spatiotemporally multiplexed two-photon excitation, this approach requires only one detector for three-dimensional particle tracking and allows for two-photon, multicolour imaging. Here we demonstrate three-dimensional tracking of epidermal growth factor receptor complexes at a depth of ~100 μm in tumour spheroids.
Implementation of a Shared Resource Financial Management System
Caldwell, T.; Gerlach, R.; Israel, M.; Bobin, S.
2010-01-01
CF-6 Norris Cotton Cancer Center (NCCC), an NCI-designated Comprehensive Cancer Center at Dartmouth Medical School, administers 12 Life Sciences Shared Resources. These resources are diverse and offer multiple products and services. Previous methods for tracking resource use, billing, and financial management were time consuming, error prone and lacked appropriate financial management tools. To address these problems, we developed and implemented a web-based application with a built-in authorization system that uses Perl, ModPerl, Apache2, and Oracle as the software infrastructure. The application uses a role-based system to differentiate administrative users with those requesting services and includes many features requested by users and administrators. To begin development, we chose a resource that had an uncomplicated service, a large number of users, and required the use of all of the applications features. The Molecular Biology Core Facility at NCCC fit these requirements and was used as a model for developing and testing the application. After model development, institution wide deployment followed a three-stage process. The first stage was to interview the resource manager and staff to understand day-to-day operations. At the second stage, we generated and tested customized forms defining resource services. During the third stage, we added new resource users and administrators to the system before final deployment. Twelve months after deployment, resource administrators reported that the new system performed well for internal and external billing and tracking resource utilization. Users preferred the application's web-based system for distribution of DNA sequencing and other data. The sample tracking features have enhanced day-to-day resource operations, and an on-line scheduling module for shared instruments has proven a much-needed utility. Principal investigators now are able to restrict user spending to specific accounts and have final approval of the invoices before the billing, which has significantly reduced the number of unpaid invoices.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-04
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0797... Request; Human Tissue Intended for Transplantation AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing that a proposed collection of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0797... Transplantation AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug... on the collection of information to the Division of Dockets Management (HFA- 305), Food and Drug...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-02
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0066... Request; Human Tissue Intended for Transplantation AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing that a proposed collection of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-12
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0731... Determination for Donors; and Current Good Tissue Practice AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing an opportunity for public comment...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-11
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0101... Determination for Donors; and Current Good Tissue Practice AGENCY: Food and Drug Administration, HHS. ACTION: Notice. SUMMARY: The Food and Drug Administration (FDA) is announcing an opportunity for public comment...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
... Communication--Knowledgeable in 1-Voting 5/31/12 risk communication, risk management, drug safety, medical..., sociology/ ethics, and other related professions. Cellular Tissue and Gene Therapies--Knowledgeable in 1... physical sciences, sociology/ethics, and other related professions. Vaccines and Related Biological...
76 FR 17135 - Clarifying Edits to Existing Special Controls Guidance Documents; Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-28
... Virus, 29. Endotoxin Assay, 30. Dental Sonography and Jaw Tracking Devices, 31. Human Dura Mater... for the Topical Approximation of Skin, 78. Bone Sonometers, 79. Tissue Expander, 80. Cord Blood...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wissel, Tobias, E-mail: wissel@rob.uni-luebeck.de; Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck; Stüber, Patrick
2016-06-01
Purpose: To support surface registration in cranial radiation therapy by structural information. The risk for spatial ambiguities is minimized by using tissue thickness variations predicted from backscattered near-infrared (NIR) light from the forehead. Methods and Materials: In a pilot study we recorded NIR surface scans by laser triangulation from 30 volunteers of different skin type. A ground truth for the soft-tissue thickness was segmented from MR scans. After initially matching the NIR scans to the MR reference, Gaussian processes were trained to predict tissue thicknesses from NIR backscatter. Moreover, motion starting from this initial registration was simulated by 5000 randommore » transformations of the NIR scan away from the MR reference. Re-registration to the MR scan was compared with and without tissue thickness support. Results: By adding prior knowledge to the backscatter features, such as incident angle and neighborhood information in the scanning grid, we showed that tissue thickness can be predicted with mean errors of <0.2 mm, irrespective of the skin type. With this additional information, the average registration error improved from 3.4 mm to 0.48 mm by a factor of 7. Misalignments of more than 1 mm were almost thoroughly (98.9%) pushed below 1 mm. Conclusions: For almost all cases tissue-enhanced matching achieved better results than purely spatial registration. Ambiguities can be minimized if the cutaneous structures do not agree. This valuable support for surface registration increases tracking robustness and avoids misalignment of tumor targets far from the registration site.« less
Dictionary learning-based spatiotemporal regularization for 3D dense speckle tracking
NASA Astrophysics Data System (ADS)
Lu, Allen; Zontak, Maria; Parajuli, Nripesh; Stendahl, John C.; Boutagy, Nabil; Eberle, Melissa; O'Donnell, Matthew; Sinusas, Albert J.; Duncan, James S.
2017-03-01
Speckle tracking is a common method for non-rigid tissue motion analysis in 3D echocardiography, where unique texture patterns are tracked through the cardiac cycle. However, poor tracking often occurs due to inherent ultrasound issues, such as image artifacts and speckle decorrelation; thus regularization is required. Various methods, such as optical flow, elastic registration, and block matching techniques have been proposed to track speckle motion. Such methods typically apply spatial and temporal regularization in a separate manner. In this paper, we propose a joint spatiotemporal regularization method based on an adaptive dictionary representation of the dense 3D+time Lagrangian motion field. Sparse dictionaries have good signal adaptive and noise-reduction properties; however, they are prone to quantization errors. Our method takes advantage of the desirable noise suppression, while avoiding the undesirable quantization error. The idea is to enforce regularization only on the poorly tracked trajectories. Specifically, our method 1.) builds data-driven 4-dimensional dictionary of Lagrangian displacements using sparse learning, 2.) automatically identifies poorly tracked trajectories (outliers) based on sparse reconstruction errors, and 3.) performs sparse reconstruction of the outliers only. Our approach can be applied on dense Lagrangian motion fields calculated by any method. We demonstrate the effectiveness of our approach on a baseline block matching speckle tracking and evaluate performance of the proposed algorithm using tracking and strain accuracy analysis.
Cruise Ship Plume Tracking Survey Report
NASA Astrophysics Data System (ADS)
2002-09-01
The U. S. Environmental Protection Agency (EPA) is developing a Cruise Ship Discharge Assessment Report in response to a petition the agency received in March 2000. The petition requested that EPA assess and where necessary control discharges from cruise ships. Comments received during public hearings, in 2000, resulted in the EPA agreeing to conduct a survey to assess the discharge plumes resulting from cruise ships, operating in ocean waters off the Florida coast and to compare the results to the Alaska dispersion models. This survey report describes the daily activities of August 2001 Cruise Ship Plume Tracking Survey, and provides a synopsis of the observations from the survey. It also provides data that can be used to assess dispersion of cruise ship wastewater discharges, while in transit. A description of the survey methods is provided in Section 2. Survey results are presented in Section 3. Findings and conclusions are discussed in Section 4.
FY02 CBNP Annual Report Input: Bioinformatics Support for CBNP Research and Deployments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slezak, T; Wolinsky, M
2002-10-31
The events of FY01 dynamically reprogrammed the objectives of the CBNP bioinformatics support team, to meet rapidly-changing Homeland Defense needs and requests from other agencies for assistance: Use computational techniques to determine potential unique DNA signature candidates for microbial and viral pathogens of interest to CBNP researcher and to our collaborating partner agencies such as the Centers for Disease Control and Prevention (CDC), U.S. Department of Agriculture (USDA), Department of Defense (DOD), and Food and Drug Administration (FDA). Develop effective electronic screening measures for DNA signatures to reduce the cost and time of wet-bench screening. Build a comprehensive system formore » tracking the development and testing of DNA signatures. Build a chain-of-custody sample tracking system for field deployment of the DNA signatures as part of the BASIS project. Provide computational tools for use by CBNP Biological Foundations researchers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hossain, S; Keeling, V; Ali, I
2015-06-15
Purpose: To determine the dosimetric impact of jaw tracking and beam energies on dose conformity and normal-brain-tissue doses for intracranial tumors using VMAT (RapidArc). Methods: Seven patients with 1–2 and three patients with 4–6 intracranial tumors were planned using RapidArc for Varian TrueBeam STx machine with beam energies 6MV-FFF (Flattening-Filter-Free), 8MV, 10MV, and 10MV-FFF. The prescription dose ranged from 14–23Gy. Between 2 and 8 arcs were used with the following geometries: 2 full coplanar arcs and the non-coplanar half arcs. Plans were optimized (jaw tracking ON) with a high priority to Normal-Tissue-Objective and normal-brain-tissue. Plans were calculated on 1mm gridmore » size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plans for the 6MV-FFF were also optimized without jaw tracking (No-JT) for comparison. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4Gy, V8Gy and V12Gy, and integral dose. Results: The average PCI ± standard deviation was 0.76±0.21 and 0.76±0.22 for 6MV-FFF and 10 MV-FFF, respectively. The average ratio in normal brain tissue volume (reported as follows V4,V8,V12) were (1.12±0.07,1.12±0.07,1.14±0.04), (1.12±0.08,1.12±0.09,1.13±0.06), (1.19±0.10,1.18±0.10,1.20±0.04), and (1.04±0.03,1.03±0.03,1.03±0.04) for 8MV/6MV-FFF, 10MV-FFF/6MV-FFF, 10MV/6MV-FFF, 6MV-FFF No-JT/6MV-FFF, respectively. Statistically significant differences in normal-brain-tissue for V4, V8, and V12 were observed in all cases for the different energies (p-values <0.05). V4 data shows significant differences in JT vs. No-JT (p=0.04), however no difference was found for V8 and V12. Brain tissue sparing from best to worst occurred in this order 6MV-FFF, 6MV-FFF no-JT, 10MV-FFF, 8MV, and 10MV. The average ratio of integral brain dose was 1.05±0.04 (p=0.21), 1.04±0.05 (p=0.33), 1.09±0.06 (p=0.04), and 1.02±0.06 (p=0.61) for 8MV/6MV-FFF, 10MV-FFF/6MV-FFF, 10MV/6MV-FFF, and 6MV-FFF No-JT/6MV-FFF, respectively. Conclusion: Normal brain tissue and integral dose improved using the lower energy and FFF beams, though plan conformity showed energy independence.« less
Operating a wide-area remote observing system for the W. M. Keck Observatory
NASA Astrophysics Data System (ADS)
Wirth, Gregory D.; Kibrick, Robert I.; Goodrich, Robert W.; Lyke, James E.
2008-07-01
For over a decade, the W. M. Keck Observatory's two 10-meter telescopes have been operated remotely from its Waimea headquarters. Over the last 6 years, WMKO remote observing has expanded to allow teams at dedicated sites in California to observe either in collaboration with colleagues in Waimea or entirely from the U.S. mainland. Once an experimental effort, the Observatory's mainland observing capability is now fully operational, supported on all science instruments (except the interferometer) and regularly used by astronomers at eight mainland sites. Establishing a convenient and secure observing capability from those sites required careful planning to ensure that they are properly equipped and configured. It also entailed a significant investment in hardware and software, including both custom scripts to simplify launching the instrument interface at remote sites and automated routers employing ISDN backup lines to ensure continuation of observing during Internet outages. Observers often wait until shortly before their runs to request use of the mainland facilities. Scheduling these requests and ensuring proper system operation prior to observing requires close coordination between personnel at WMKO and the mainland sites. An established protocol for approving requests and carrying out pre-run checkout has proven useful in ensuring success. The Observatory anticipates enhancing and expanding its remote observing system. Future plans include deploying dedicated summit computers for running VNC server software, implementing a web-based tracking system for mainland-based observing requests, expanding the system to additional mainland sites, and converting to full-time VNC operation for all instruments.
NASA Technical Reports Server (NTRS)
Shavers, M. R.; Atwell, W.; Cucinotta, F. A.; Badhwar, G. D. (Technical Monitor)
1999-01-01
Radiation shield design is driven by the need to limit radiation risks while optimizing risk reduction with launch mass/expense penalties. Both limitation and optimization objectives require the development of accurate and complete means for evaluating the effectiveness of various shield materials and body-self shielding. For galactic cosmic rays (GCR), biophysical response models indicate that track structure effects lead to substantially different assessments of shielding effectiveness relative to assessments based on LET-dependent quality factors. Methods for assessing risk to the central nervous system (CNS) from heavy ions are poorly understood at this time. High-energy and charge (HZE) ion can produce tissue events resulting in damage to clusters of cells in a columnar fashion, especially for stopping heavy ions. Grahn (1973) and Todd (1986) have discussed a microlesion concept or model of stochastic tissue events in analyzing damage from HZE's. Some tissues, including the CNS, maybe sensitive to microlesion's or stochastic tissue events in a manner not illuminated by either conventional dosimetry or fluence-based risk factors. HZE ions may also produce important lateral damage to adjacent cells. Fluences of high-energy proton and alpha particles in the GCR are many times higher than HZE ions. Behind spacecraft and body self-shielding the ratio of protons, alpha particles, and neutrons to HZE ions increases several-fold from free-space values. Models of GCR damage behind shielding have placed large concern on the role of target fragments produced from tissue atoms. The self-shielding of the brain reduces the number of heavy ions reaching the interior regions by a large amount and the remaining light particle environment (protons, neutrons, deuterons. and alpha particles) may be the greatest concern. Tracks of high-energy proton produce nuclear reactions in tissue, which can deposit doses of more than 1 Gv within 5 - 10 cell layers. Information on rates of cell killing from GCR, including patterns of cell killing from single particle tracks. can provide useful information on expected differences between proton and HZE tracks and clinical experiences with photon irradiation. To model effects on cells in the brain, it is important that transport models accurately describe changes in the GCR due to interactions in the cranium and proximate tissues. We describe calculations of the attenuated GCR particle fluxes at three dose-points in the brain and associated patterns of cell killing using biophysical models. The effects of the brain self-shielding and bone-tissue interface of the skull in modulating the GCR environment are considered. For each brain dose-point, the mass distribution in the surrounding 4(pi) solid angle is characterized using the CAM model to trace 512 rays. The CAM model describes the self-shielding by converting the tissue distribution to mass-equivalent aluminum, and nominal values of spacecraft shielding is considered. Particle transport is performed with the proton, neutron, and heavy-ion transport code HZETRN with the nuclear fragmentation model QMSFRG. The distribution of cells killed along the path of individual GCR ions is modeled using in vitro cell inactivation data for cells with varying sensitivity. Monte Carlo simulations of arrays of inactivated cells are considered for protons and heavy ions and used to describe the absolute number of cell killing events of various magnitude in the brain from the GCR. Included are simulations of positions of inactivated cells from stopping heavy ions and nuclear stars produced by high-energy ions most importantly, protons and neutrons.
Intravital third harmonic generation microscopy of collective melanoma cell invasion
Weigelin, Bettina; Bakker, Gert-Jan; Friedl, Peter
2012-01-01
Cancer cell invasion is an adaptive process based on cell-intrinsic properties to migrate individually or collectively, and their adaptation to encountered tissue structure acting as barrier or providing guidance. Whereas molecular and physical mechanisms of cancer invasion are well-studied in 3D in vitro models, their topographic relevance, classification and validation toward interstitial tissue organization in vivo remain incomplete. Using combined intravital third and second harmonic generation (THG, SHG), and three-channel fluorescence microscopy in live tumors, we here map B16F10 melanoma invasion into the dermis with up to 600 µm penetration depth and reconstruct both invasion mode and tissue tracks to establish invasion routes and outcome. B16F10 cells preferentially develop adaptive invasion patterns along preformed tracks of complex, multi-interface topography, combining single-cell and collective migration modes, without immediate anatomic tissue remodeling or destruction. The data suggest that the dimensionality (1D, 2D, 3D) of tissue interfaces determines the microanatomy exploited by invading tumor cells, emphasizing non-destructive migration along microchannels coupled to contact guidance as key invasion mechanisms. THG imaging further detected the presence and interstitial dynamics of tumor-associated microparticles with submicron resolution, revealing tumor-imposed conditioning of the microenvironment. These topographic findings establish combined THG, SHG and fluorescence microscopy in intravital tumor biology and provide a template for rational in vitro model development and context-dependent molecular classification of invasion modes and routes. PMID:29607252
Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph
2017-06-01
Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.
Houot, Benjamin; Gigot, Vincent; Robichon, Alain; Ferveur, Jean-François
2017-01-01
The evolution of powered flight in insects had major consequences for global biodiversity and involved the acquisition of adaptive processes allowing individuals to disperse to new ecological niches. Flies use both vision and olfactory input from their antennae to guide their flight; chemosensors on fly wings have been described, but their function remains mysterious. We studied Drosophila flight in a wind tunnel. By genetically manipulating wing chemosensors, we show that these structures play an essential role in flight performance with a sex-specific effect. Pheromonal systems are also involved in Drosophila flight guidance: transgenic expression of the pheromone production and detection gene, desat1, produced low, rapid flight that was absent in control flies. Our study suggests that the sex-specific modulation of free-flight odor tracking depends on gene expression in various fly tissues including wings and pheromonal-related tissues. PMID:28067325
The cellular basis for animal regeneration
Tanaka, Elly; Reddien, Peter W.
2011-01-01
The ability of animals to regenerate missing parts is a dramatic and poorly understood aspect of biology. The sources of new cells for these regenerative phenomena have been sought for decades. Recent advances involving cell fate tracking in complex tissues have shed new light on the cellular underpinnings of regeneration in Hydra, planarians, zebrafish, Xenopus, and Axolotl. Planarians accomplish regeneration with use of adult pluripotent stem cells, whereas several vertebrates utilize a collection of lineage-restricted progenitors from different tissues. Together, an array of cellular strategies—from pluripotent stem cells to tissue-specific stem cells and dedifferentiation—are utilized for regeneration. PMID:21763617
A contribution to the discussion on the safety of air weapons.
Wightman, G; Cochrane, R; Gray, R A; Linton, M
2013-09-01
Firearms legislation in the UK stems from the Firearms Act 1968 with its definition of a firearm as a lethal barrelled weapon of any description. The Act allows certain exceptions to be held without licence, most notably air weapons although these are limited by The Firearms (Dangerous Air Weapons) Rules 1969 and related regulations to below 12ft lb (16.3J) for air rifles and below 6ft lb (8.1J) for air pistols. Despite this there are occasional fatalities, typically 1 or 2 each year in the UK, from legally owned air weapons. In the USA there are over 20,000 visits each year to emergency departments due to injuries from air weapons and paintball guns. Despite this, limited research appears to have been carried out into the safety of air weapons and the present study tries to address this. Fresh samples of animal tissue were obtained from an abattoir or butcher and were embedded in ballistic gelatin. Pig heart, lung, liver and shoulder were used. By firing pellets into gelatin alone and into the combination of the gelatin and animal tissue it was possible to compare gelatin as a model for these tissues. The depth of penetration was similar but the residual track appeared to remain more open in the animal tissue. Pellets penetrated completely through the organ, with total penetration of gelatin and organ being typically around 10-15cm. Samples of pig, cow and chicken skin were placed in contact with the gelatin or embedded in the gelatin to simulate the effect of skin on penetration into a body. Chicken skin had no effect, pig skin stopped the pellet and cow skin was perforated by the pellet. If cow skin was embedded in the gelatin there was little effect on the total amount of penetration, but cow skin on the front surface of the gelatin reduced penetration by about 30%. Computed tomography was used to examine the pellet track and to calculate the volume of damage produced. However, due to the similar densities of gelatin and organ a technique had to be developed to differentiate phases. A barium salt paste was applied to outer surfaces and iodine solution or barium nitrate solution containing red food colouring was injected into the pellet track to enhance the contrast of the track. The track through the gelatin tended to enclose itself whereas the track through the organ remained more open, presumably due to the inhomogeneity of the fibrous nature of the tissue. Pellets were also fired at construction materials (wood, plasterboard and brick) and computed tomography used to determine the volume of damage created. Pellets perforated single layers of wood and plasterboard and would embed in a second layer. However, if the two layers were in contact the pellet did not penetrate the first layer. An air rifle pellet could therefore perforate house construction materials, although the resultant kinetic energy would be low and further damage would be limited. Some of the possible physical parameters are discussed that might help predict the degree of damage caused, but from this study it is not possible to define a limit which could be proposed as safe. Copyright © 2012 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Yunnan-III models for evolutionary population synthesis
NASA Astrophysics Data System (ADS)
Zhang, F.; Li, L.; Han, Z.; Zhuang, Y.; Kang, X.
2013-02-01
We build the Yunnan-III evolutionary population synthesis (EPS) models by using the mesa stellar evolution code, BaSeL stellar spectra library and the initial mass functions (IMFs) of Kroupa and Salpeter, and present colours and integrated spectral energy distributions (ISEDs) of solar-metallicity stellar populations (SPs) in the range of 1 Myr to 15 Gyr. The main characteristic of the Yunnan-III EPS models is the usage of a set of self-consistent solar-metallicity stellar evolutionary tracks (the masses of stars are from 0.1 to 100 M⊙). This set of tracks is obtained by using the state-of-the-art mesa code. mesa code can evolve stellar models through thermally pulsing asymptotic giant branch (TP-AGB) phase for low- and intermediate-mass stars. By comparisons, we confirm that the inclusion of TP-AGB stars makes the V - K, V - J and V - R colours of SPs redder and the infrared flux larger at ages log(t/yr) ≳ 7.6 [the differences reach the maximum at log(t/yr) ˜ 8.6, ˜0.5-0.2 mag for colours, approximately two times for K-band flux]. We also find that the colour-evolution trends of Model with-TPAGB at intermediate and large ages are similar to those from the starburst99 code, which employs the Padova-AGB stellar library, BaSeL spectral library and the Kroupa IMF. At last, we compare the colours with the other EPS models comprising TP-AGB stars (such as CB07, M05, V10 and POPSTAR), and find that the B - V colour agrees with each other but the V-K colour shows a larger discrepancy among these EPS models [˜1 mag when 8 ≲ log(t/yr) ≲ 9]. The stellar evolutionary tracks, isochrones, colours and ISEDs can be obtained on request from the first author or from our website (http://www1.ynao.ac.cn/~zhangfh/). Using the isochrones, you can build your EPS models. Now the format of stellar evolutionary tracks is the same as that in the starburst99 code; you can put them into the starburst99 code and get the SP's results. Moreover, the colours involving other passbands or on other systems (e.g. HST F439W - F555W colour on AB system) can also be obtained on request.
Human Spaceflight Recent Conjunctions of Interest
NASA Technical Reports Server (NTRS)
Browns, Ansley C.
2010-01-01
I. During each nine-hour shift (or upon request), the Orbital Safety Analyst (OSA) at JSpOC updates the entire tracked catalog with the latest tracking data from the SSN and screens this catalog against NASA s assets. a) For ISS operations, a 72-hour advance screening is performed. b) For Shuttle orbit operations, a 36-hour advance screening is performed. c) If a vehicle is performing a maneuver during the screening period, OSA uses post-reboost-trajectory data supplied by Mission Control Center-Houston (MCC-H) for screening. II. An automated process is used to detect any conjunctions within 10 x 40 x 40 km box (centered on the vehicle) using Special Perturbation (SP) processing: a) Box dimensions are Radial x Downtrack x Crosstrack. b) Any object found within this box has the tracking tasking level increased to improve (hopefully) its uncertainty in its current and predicted orbital trajectory. c) OSA informs NASA if any object is found inside a 2 x 25 x 25 km box then creates and sends an Orbital Conjunction Message (OCM) to NASA which contains detailed information about the conjunction. d) For Shuttle, the box size used for screening and reporting is altered for special operations (day of rendezvous, launch screening, etc.).
Trajectory Specification for High-Capacity Air Traffic Control
NASA Technical Reports Server (NTRS)
Paielli, Russell A.
2004-01-01
In the current air traffic management system, the fundamental limitation on airspace capacity is the cognitive ability of human air traffic controllers to maintain safe separation with high reliability. The doubling or tripling of airspace capacity that will be needed over the next couple of decades will require that tactical separation be at least partially automated. Standardized conflict-free four-dimensional trajectory assignment will be needed to accomplish that objective. A trajectory specification format based on the Extensible Markup Language is proposed for that purpose. This format can be used to downlink a trajectory request, which can then be checked on the ground for conflicts and approved or modified, if necessary, then uplinked as the assigned trajectory. The horizontal path is specified as a series of geodetic waypoints connected by great circles, and the great-circle segments are connected by turns of specified radius. Vertical profiles for climb and descent are specified as low-order polynomial functions of along-track position, which is itself specified as a function of time. Flight technical error tolerances in the along-track, cross-track, and vertical axes define a bounding space around the reference trajectory, and conformance will guarantee the required separation for a period of time known as the conflict time horizon. An important safety benefit of this regimen is that the traffic will be able to fly free of conflicts for at least several minutes even if all ground systems and the entire communication infrastructure fail. Periodic updates in the along-track axis will adjust for errors in the predicted along-track winds.
Yeo, Boon Y.; McLaughlin, Robert A.; Kirk, Rodney W.; Sampson, David D.
2012-01-01
We present a high-resolution three-dimensional position tracking method that allows an optical coherence tomography (OCT) needle probe to be scanned laterally by hand, providing the high degree of flexibility and freedom required in clinical usage. The method is based on a magnetic tracking system, which is augmented by cross-correlation-based resampling and a two-stage moving window average algorithm to improve upon the tracker's limited intrinsic spatial resolution, achieving 18 µm RMS position accuracy. A proof-of-principle system was developed, with successful image reconstruction demonstrated on phantoms and on ex vivo human breast tissue validated against histology. This freehand scanning method could contribute toward clinical implementation of OCT needle imaging. PMID:22808429
Xu, Tong; Ducote, Justin L.; Wong, Jerry T.; Molloi, Sabee
2011-01-01
Dual-energy chest radiography has the potential to provide better diagnosis of lung disease by removing the bone signal from the image. Dynamic dual-energy radiography is now possible with the introduction of digital flat panel detectors. The purpose of this study is to evaluate the feasibility of using dynamic dual-energy chest radiography for functional lung imaging and tumor motion assessment. The dual energy system used in this study can acquire up to 15 frame of dual-energy images per second. A swine animal model was mechanically ventilated and imaged using the dual-energy system. Sequences of soft-tissue images were obtained using dual-energy subtraction. Time subtracted soft-tissue images were shown to be able to provide information on regional ventilation. Motion tracking of a lung anatomic feature (a branch of pulmonary artery) was performed based on an image cross-correlation algorithm. The tracking precision was found to be better than 1 mm. An adaptive correlation model was established between the above tracked motion and an external surrogate signal (temperature within the tracheal tube). This model is used to predict lung feature motion using the continuous surrogate signal and low frame rate dual-energy images (0.1 to 3.0 frames /sec). The average RMS error of the prediction was (1.1 ± 0.3) mm. The dynamic dual-energy was shown to be potentially useful for lung functional imaging such as regional ventilation and kinetic studies. It can also be used for lung tumor motion assessment and prediction during radiation therapy. PMID:21285477
A parallelizable real-time motion tracking algorithm with applications to ultrasonic strain imaging
NASA Astrophysics Data System (ADS)
Jiang, J.; Hall, T. J.
2007-07-01
Ultrasound-based mechanical strain imaging systems utilize signals from conventional diagnostic ultrasound systems to image tissue elasticity contrast that provides new diagnostically valuable information. Previous works (Hall et al 2003 Ultrasound Med. Biol. 29 427, Zhu and Hall 2002 Ultrason. Imaging 24 161) demonstrated that uniaxial deformation with minimal elevation motion is preferred for breast strain imaging and real-time strain image feedback to operators is important to accomplish this goal. The work reported here enhances the real-time speckle tracking algorithm with two significant modifications. One fundamental change is that the proposed algorithm is a column-based algorithm (a column is defined by a line of data parallel to the ultrasound beam direction, i.e. an A-line), as opposed to a row-based algorithm (a row is defined by a line of data perpendicular to the ultrasound beam direction). Then, displacement estimates from its adjacent columns provide good guidance for motion tracking in a significantly reduced search region to reduce computational cost. Consequently, the process of displacement estimation can be naturally split into at least two separated tasks, computed in parallel, propagating outward from the center of the region of interest (ROI). The proposed algorithm has been implemented and optimized in a Windows® system as a stand-alone ANSI C++ program. Results of preliminary tests, using numerical and tissue-mimicking phantoms, and in vivo tissue data, suggest that high contrast strain images can be consistently obtained with frame rates (10 frames s-1) that exceed our previous methods.
Real-time soft tissue motion estimation for lung tumors during radiotherapy delivery.
Rottmann, Joerg; Keall, Paul; Berbeco, Ross
2013-09-01
To provide real-time lung tumor motion estimation during radiotherapy treatment delivery without the need for implanted fiducial markers or additional imaging dose to the patient. 2D radiographs from the therapy beam's-eye-view (BEV) perspective are captured at a frame rate of 12.8 Hz with a frame grabber allowing direct RAM access to the image buffer. An in-house developed real-time soft tissue localization algorithm is utilized to calculate soft tissue displacement from these images in real-time. The system is tested with a Varian TX linear accelerator and an AS-1000 amorphous silicon electronic portal imaging device operating at a resolution of 512 × 384 pixels. The accuracy of the motion estimation is verified with a dynamic motion phantom. Clinical accuracy was tested on lung SBRT images acquired at 2 fps. Real-time lung tumor motion estimation from BEV images without fiducial markers is successfully demonstrated. For the phantom study, a mean tracking error <1.0 mm [root mean square (rms) error of 0.3 mm] was observed. The tracking rms accuracy on BEV images from a lung SBRT patient (≈20 mm tumor motion range) is 1.0 mm. The authors demonstrate for the first time real-time markerless lung tumor motion estimation from BEV images alone. The described system can operate at a frame rate of 12.8 Hz and does not require prior knowledge to establish traceable landmarks for tracking on the fly. The authors show that the geometric accuracy is similar to (or better than) previously published markerless algorithms not operating in real-time.
Xu, Tong; Ducote, Justin L; Wong, Jerry T; Molloi, Sabee
2011-02-21
Dual-energy chest radiography has the potential to provide better diagnosis of lung disease by removing the bone signal from the image. Dynamic dual-energy radiography is now possible with the introduction of digital flat-panel detectors. The purpose of this study is to evaluate the feasibility of using dynamic dual-energy chest radiography for functional lung imaging and tumor motion assessment. The dual-energy system used in this study can acquire up to 15 frames of dual-energy images per second. A swine animal model was mechanically ventilated and imaged using the dual-energy system. Sequences of soft-tissue images were obtained using dual-energy subtraction. Time subtracted soft-tissue images were shown to be able to provide information on regional ventilation. Motion tracking of a lung anatomic feature (a branch of pulmonary artery) was performed based on an image cross-correlation algorithm. The tracking precision was found to be better than 1 mm. An adaptive correlation model was established between the above tracked motion and an external surrogate signal (temperature within the tracheal tube). This model is used to predict lung feature motion using the continuous surrogate signal and low frame rate dual-energy images (0.1-3.0 frames per second). The average RMS error of the prediction was (1.1 ± 0.3) mm. The dynamic dual energy was shown to be potentially useful for lung functional imaging such as regional ventilation and kinetic studies. It can also be used for lung tumor motion assessment and prediction during radiation therapy.
Ultrasound elastography: principles, techniques, and clinical applications.
Dewall, Ryan J
2013-01-01
Ultrasound elastography is an emerging set of imaging modalities used to image tissue elasticity and are often referred to as virtual palpation. These techniques have proven effective in detecting and assessing many different pathologies, because tissue mechanical changes often correlate with tissue pathological changes. This article reviews the principles of ultrasound elastography, many of the ultrasound-based techniques, and popular clinical applications. Originally, elastography was a technique that imaged tissue strain by comparing pre- and postcompression ultrasound images. However, new techniques have been developed that use different excitation methods such as external vibration or acoustic radiation force. Some techniques track transient phenomena such as shear waves to quantitatively measure tissue elasticity. Clinical use of elastography is increasing, with applications including lesion detection and classification, fibrosis staging, treatment monitoring, vascular imaging, and musculoskeletal applications.
Bharat, Shyam; Varghese, Tomy
2010-10-01
Quasi-static electrode displacement elastography, used for in-vivo imaging of radiofrequency ablation-induced lesions in abdominal organs such as the liver and kidney, is extended in this paper to dynamic vibrational perturbations of the ablation electrode. Propagation of the resulting shear waves into adjoining regions of tissue can be tracked and the shear wave velocity used to quantify the shear (and thereby Young's) modulus of tissue. The algorithm used utilizes the time-to-peak displacement data (obtained from finite element analyses) to calculate the speed of shear wave propagation in the material. The simulation results presented illustrate the feasibility of estimating the Young's modulus of tissue and is promising for characterizing the stiffness of radiofrequency-ablated thermal lesions and surrounding normal tissue.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-24
... Paperwork Reduction Act of 1995, this notice announces the Animal and Plant Health Inspection Service's... establishments, contact Dr. Debra Cox, Senior Staff Veterinarian, Surveillance and Identification Programs, NCAHP... information collection. Abstract: Under the Animal Health Protection Act (7 U.S.C. 8301 et seq.), the Animal...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
... regarding the use of edible tissues from investigational animals. Part 511 also requires that records be... Request; New Animal Drugs for Investigational Uses AGENCY: Food and Drug Administration, HHS. [[Page 59140.... New Animal Drugs for Investigational Uses--21 CFR Part 511 (OMB Control Number 0910-0117)--Extension...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-07
... and tailored support for national and international biobanks. The survey will collect a combination of structured, quantitative, and free-text descriptive data that characterize the type and maturity of... Collection: The purpose of this web- based survey is to collect information regarding the challenges that...
The U.S. Rosetta Project : eighteen months in flight
NASA Technical Reports Server (NTRS)
Alexander, Claudia J.; Gulkis, Samuel; Frerking, Margaret A.; Holmes, Dwight P.; Weissman, Paul A.; Burch, J.; Stern, A.; Goldstein, R.; Parker, J.; Cravens, T.;
2006-01-01
In this paper we will update the status of the instruments following the commissioning exercise, an exercise that was only partially complete when a report was prepared for the 2005 IEEE conference.We will present an overview of the 2005 Earth/Moon activities, and the Deep Impact set of observations. The paper will also provide an update of the role of NASA's Deep Space Network in supporting an ESA request for Delta Difference One-way Ranging to provide improved tracking and navigation capability in preparation for the Mars flyby in 2007.
Configuration management issues and objectives for a real-time research flight test support facility
NASA Technical Reports Server (NTRS)
Yergensen, Stephen; Rhea, Donald C.
1988-01-01
An account is given of configuration management activities for the Western Aeronautical Test Range (WATR) at NASA-Ames, whose primary function is the conduct of aeronautical research flight testing through real-time processing and display, tracking, and communications systems. The processing of WATR configuration change requests for specific research flight test projects must be conducted in such a way as to refrain from compromising the reliability of WATR support to all project users. Configuration management's scope ranges from mission planning to operations monitoring and performance trend analysis.
Automating the Processing of Earth Observation Data
NASA Technical Reports Server (NTRS)
Golden, Keith; Pang, Wan-Lin; Nemani, Ramakrishna; Votava, Petr
2003-01-01
NASA s vision for Earth science is to build a "sensor web": an adaptive array of heterogeneous satellites and other sensors that will track important events, such as storms, and provide real-time information about the state of the Earth to a wide variety of customers. Achieving this vision will require automation not only in the scheduling of the observations but also in the processing of the resulting data. To address this need, we are developing a planner-based agent to automatically generate and execute data-flow programs to produce the requested data products.
1984-02-01
1,813,700 2,184,600 1,835,000 Direct Obligation Section 1 - PURPOSE AND SCOPE Provides for procurement and manufacture of airplates, helicopters, and...installation unless the item is furnished to a manufacturer , who provides parts and labor under a single contract (excluding normal GFE). This...of $17.0 milion is requested in FY 1985 to fund long leand items associated with the JOINT STABS ground stations, These ground stations will provide
Electronic Derivative Classifier/Reviewing Official
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Joshua C; McDuffie, Gregory P; Light, Ken L
2017-02-17
The electronic Derivative Classifier, Reviewing Official (eDC/RO) is a web based document management and routing system that reduces security risks and increases workflow efficiencies. The system automates the upload, notification review request, and document status tracking of documents for classification review on a secure server. It supports a variety of document formats (i.e., pdf, doc, docx, xls, xlsx, xlsm, ppt, pptx, vsd, vsdx and txt), and allows for the dynamic placement of classification markings such as the classification level, category and caveats on the document, in addition to a document footer and digital signature.
Yang, Xiaochen; Clements, Logan W; Luo, Ma; Narasimhan, Saramati; Thompson, Reid C; Dawant, Benoit M; Miga, Michael I
2017-07-01
Intraoperative soft tissue deformation, referred to as brain shift, compromises the application of current image-guided surgery navigation systems in neurosurgery. A computational model driven by sparse data has been proposed as a cost-effective method to compensate for cortical surface and volumetric displacements. We present a mock environment developed to acquire stereoimages from a tracked operating microscope and to reconstruct three-dimensional point clouds from these images. A reconstruction error of 1 mm is estimated by using a phantom with a known geometry and independently measured deformation extent. The microscope is tracked via an attached tracking rigid body that facilitates the recording of the position of the microscope via a commercial optical tracking system as it moves during the procedure. Point clouds, reconstructed under different microscope positions, are registered into the same space to compute the feature displacements. Using our mock craniotomy device, realistic cortical deformations are generated. When comparing our tracked microscope stereo-pair measure of mock vessel displacements to that of the measurement determined by the independent optically tracked stylus marking, the displacement error was [Formula: see text] on average. These results demonstrate the practicality of using tracked stereoscopic microscope as an alternative to laser range scanners to collect sufficient intraoperative information for brain shift correction.
3D Visualization of Monte-Carlo Simulation's of HZE Track Structure and Initial Chemical Species
NASA Technical Reports Server (NTRS)
Plante, Ianik; Cucinotta, Francis A.
2009-01-01
Heavy ions biophysics is important for space radiation risk assessment [1] and hadron-therapy [2]. The characteristic of heavy ions tracks include a very high energy deposition region close to the track (<20 nm) denoted as the track core, and an outer penumbra region consisting of individual secondary electrons (6-rays). A still open question is the radiobiological effects of 6- rays relative to the track core. Of importance is the induction of double-strand breaks (DSB) [3] and oxidative damage to the biomolecules and the tissue matrix, considered the most important lesions for acute and long term effects of radiation. In this work, we have simulated a 56Fe26+ ion track of 1 GeV/amu with our Monte-Carlo code RITRACKS [4]. The simulation results have been used to calculate the energy depiction and initial chemical species in a "voxelized" space, which is then visualized in 3D. Several voxels with dose >1000 Gy are found in the penumbra, some located 0.1 mm from the track core. In computational models, the DSB induction probability is calculated with radial dose [6], which may not take into account the higher RBE of electron track ends for DSB induction. Therefore, these simulations should help improve models of DSB induction and our understanding of heavy ions biophysics.
A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.
Mung, Jay; Vignon, Francois; Jain, Ameet
2011-01-01
In the past decade ultrasound (US) has become the preferred modality for a number of interventional procedures, offering excellent soft tissue visualization. The main limitation however is limited visualization of surgical tools. A new method is proposed for robust 3D tracking and US image enhancement of surgical tools under US guidance. Small US sensors are mounted on existing surgical tools. As the imager emits acoustic energy, the electrical signal from the sensor is analyzed to reconstruct its 3D coordinates. These coordinates can then be used for 3D surgical navigation, similar to current day tracking systems. A system with real-time 3D tool tracking and image enhancement was implemented on a commercial ultrasound scanner and 3D probe. Extensive water tank experiments with a tracked 0.2mm sensor show robust performance in a wide range of imaging conditions and tool position/orientations. The 3D tracking accuracy was 0.36 +/- 0.16mm throughout the imaging volume of 55 degrees x 27 degrees x 150mm. Additionally, the tool was successfully tracked inside a beating heart phantom. This paper proposes an image enhancement and tool tracking technology with sub-mm accuracy for US-guided interventions. The technology is non-disruptive, both in terms of existing clinical workflow and commercial considerations, showing promise for large scale clinical impact.
Experimental Validation of Displacement Underestimation in ARFI Ultrasound
Czernuszewicz, Tomasz J.; Streeter, Jason E.; Dayton, Paul A.; Gallippi, Caterina M.
2014-01-01
Acoustic radiation force impulse (ARFI) imaging is an elastography technique that uses ultrasonic pulses to both displace and track tissue motion. Previous modeling studies have shown that ARFI displacements are susceptible to underestimation due to lateral and elevational shearing that occurs within the tracking resolution cell. In this study, optical tracking was utilized to experimentally measure the displacement underestimation achieved by acoustic tracking using a clinical ultrasound system. Three optically translucent phantoms of varying stiffness were created, embedded with sub-wavelength diameter microspheres, and ARFI excitation pulses with F/1.5 or F/3 lateral focal configurations were transmitted from a standard linear array to induce phantom motion. Displacements were tracked using confocal optical and acoustic methods. As predicted by earlier FEM studies, significant acoustic displacement underestimation was observed for both excitation focal configurations; the maximum underestimation error was 35% of the optically measured displacement for the F/1.5 excitation pulse in the softest phantom. Using higher F/#, less tightly focused beams in the lateral dimension improved accuracy of displacements by approximately 10 percentage points. This work experimentally demonstrates limitations of ARFI implemented on a clinical scanner using a standard linear array and sets up a framework for future displacement tracking validation studies. PMID:23858054
Shchory, Tal; Schifter, Dan; Lichtman, Rinat; Neustadter, David; Corn, Benjamin W
2010-11-15
In radiation therapy there is a need to accurately know the location of the target in real time. A novel radioactive tracking technology has been developed to answer this need. The technology consists of a radioactive implanted fiducial marker designed to minimize migration and a linac mounted tracking device. This study measured the static and dynamic accuracy of the new tracking technology in a clinical radiation therapy environment. The tracking device was installed on the linac gantry. The radioactive marker was located in a tissue equivalent phantom. Marker location was measured simultaneously by the radioactive tracking system and by a Microscribe G2 coordinate measuring machine (certified spatial accuracy of 0.38 mm). Localization consistency throughout a volume and absolute accuracy in the Fixed coordinate system were measured at multiple gantry angles over volumes of at least 10 cm in diameter centered at isocenter. Dynamic accuracy was measured with the marker located inside a breathing phantom. The mean consistency for the static source was 0.58 mm throughout the tested region at all measured gantry angles. The mean absolute position error in the Fixed coordinate system for all gantry angles was 0.97 mm. The mean real-time tracking error for the dynamic source within the breathing phantom was less than 1 mm. This novel radioactive tracking technology has the potential to be useful in accurate target localization and real-time monitoring for radiation therapy. Copyright © 2010 Elsevier Inc. All rights reserved.
Validating Ultrasound-based HIFU Lesion-size Monitoring Technique with MR Thermometry and Histology
NASA Astrophysics Data System (ADS)
Zhou, Shiwei; Petruzzello, John; Anand, Ajay; Sethuraman, Shriram; Azevedo, Jose
2010-03-01
In order to control and monitor HIFU lesions accurately and cost-effectively in real-time, we have developed an ultrasound-based therapy monitoring technique using acoustic radiation force to track the change in tissue mechanical properties. We validate our method with concurrent MR thermometry and histology. Comparison studies have been completed on in-vitro bovine liver samples. A single-element 1.1 MHz focused transducer was used to deliver HIFU and produce acoustic radiation force (ARF). A 5 MHz single-element transducer was placed co-axially with the HIFU transducer to acquire the RF data, and track the tissue displacement induced by ARF. During therapy, the monitoring procedure was interleaved with HIFU. MR thermometry (Philips Panorama 1T system) and ultrasound monitoring were performed simultaneously. The tissue temperature and thermal dose (CEM43 = 240 mins) were computed from the MR thermometry data. The tissue displacement induced by the acoustic radiation force was calculated from the ultrasound RF data in real-time using a cross-correlation based method. A normalized displacement difference (NDD) parameter was developed and calibrated to estimate the lesion size. The lesion size estimated by the NDD was compared with both MR thermometry prediction and the histology analysis. For lesions smaller than 8mm, the NDD-based lesion monitoring technique showed very similar performance as MR thermometry. The standard deviation of lesion size error is 0.66 mm, which is comparable to MR thermal dose contour prediction (0.42 mm). A phased array is needed for tracking displacement in 2D and monitoring lesion larger than 8 mm. The study demonstrates the potential of our ultrasound based technique to achieve precise HIFU lesion control through real-time monitoring. The results compare well with histology and an established technique like MR Thermometry. This approach provides feedback control in real-time to terminate therapy when a pre-determined lesion size is achieved, and can be extended to 2D and implemented on commercial ultrasound scanner systems.
Track structure model for damage to mammalian cell cultures during solar proton events
NASA Technical Reports Server (NTRS)
Cucinotta, F. A.; Wilson, J. W.; Townsend, L. W.; Shinn, J. L.; Katz, R.
1992-01-01
Solar proton events (SPEs) occur infrequently and unpredictably, thus representing a potential hazard to interplanetary space missions. Biological damage from SPEs will be produced principally through secondary electron production in tissue, including important contributions due to delta rays from nuclear reaction products. We review methods for estimating the biological effectiveness of SPEs using a high energy proton model and the parametric cellular track model. Results of the model are presented for several of the historically largest flares using typical levels and body shielding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kathy Held; Kevin Prise; Barry Michael
The management of the risks of exposure of people to ionizing radiation is important in relation to its uses in industry and medicine, also to natural and man-made radiation in the environment. The vase majority of exposures are at a very low level of radiation dose. The risks are of inducing cancer in the exposed individuals and a smaller risk of inducing genetic damage that can be indicate that they are low. As a result, the risks are impossible to detect in population studies with any accuracy above the normal levels of cancer and genetic defects unless the dose levelsmore » are high. In practice, this means that our knowledge depends very largely on the information gained from the follow-up of the survivors of the atomic bombs dropped on Japanese cities. The risks calculated from these high-dose short-duration exposures then have to be projected down to the low-dose long-term exposures that apply generally. Recent research using cells in culture has revealed that the relationship between high- and low-dose biological damage may be much more complex than had previously been thought. The aims of this and other projects in the DOE's Low-Dose Program are to gain an understanding of the biological actions of low-dose radiation, ultimately to provide information that will lead to more accurate quantification of low-dose risk. Our project is based on the concept that the processes by which radiation induces cancer start where the individual tracks of radiation impact on cells and tissues. At the dose levels of most low-dose exposures, these events are rare and any individual cells only ''sees'' radiation tracks at intervals averaging from weeks to years apart. This contrasts with the atomic bomb exposures where, on average, each cell was hit by hundreds of tracks instantaneously. We have therefore developed microbeam techniques that enable us to target cells in culture with any numbers of tracks, from one upwards. This approach enables us to study the biological ha sis of the relationship between high- and low-dose exposures. The targeting approach also allows us to study very clearly a newly recognized effect of radiation, the ''bystander effect'', which appears to dominate some low-dose responses and therefore may have a significant role in low-dose risk mechanisms. Our project also addresses the concept that the background of naturally occurring oxidative damage that takes place continually in cells due to byproducts of metabolism may play a role in low-dose radiation risk. This project therefore also examines how cells are damaged by treatments that modify the levels of oxidative damage, either alone or in combination with low-dose irradiation. In this project, we have used human and rodent cell lines and each set of experiments has been carried out on a single cell type. However, low-dose research has to extend into tissues because signaling between cells of different types is likely to influence the responses. Our studies have therefore also included microbeam experiments using a model tissue system that consists of an explant of a small piece of pig ureter grown in culture. The structure of this tissue is similar to that of epithelium and therefore it relates to the tissues in which carcinoma arises. Our studies have been able to measure bystander-induced changes in the cells growing out from the tissue fragment after it has been targeted with a few radiation tracks to mimic a low-dose exposure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barry D. Michael; Kathryn Held; Kevin Prise
The management of the risks of exposure of people to ionizing radiation is important in relation to its uses in industry and medicine, also to natural and man-made radiation in the environment. The vase majority of exposures are at a very low level of radiation dose. The risks are of inducing cancer in the exposed individuals and a smaller risk of inducing genetic damage that can be transmitted to children conceived after exposure. Studies of these risks in exposed population studies with any accuracy above the normal levels of cancer and genetic defects unless the dose levels are high. Inmore » practice, this means that our knowledge depends very largely on the information gained from the follow-up of the survivors of the atomic bombs dropped on Japanese cities. The risks calculated from these high-dose short-duration exposures then have to be projected down to the low-dose long-term exposures that apply generally. Recent research using cells in culture has revealed that the relations hi between high- and low-dose biological damage may be much more complex than had previously been thought. The aims of this and other projects in the DOE's Low-Dose Program are to gain an understanding of the biological actions of low-dose radiation, ultimately to provide information that will lead to more accurate quantification of low-dose risk. Our project is based on the concept that the processes by which radiation induces cancer start where the individual tracks of radiation impact on cells and tissues. At the dose levels of most low-dose exposures, these events are rare and any individual cells only ''sees'' radiation tracks at intervals averaging from weeks to years apart. This contracts with the atomic bomb exposures where, on average, each cell was hit by hundreds of tracks instantaneously. We have therefore developed microbeam techniques that enable us to target cells in culture with any number of tracks, from one upwards. This approach enables us to study the biological basis of the relationship between high- and low-dose exposures. The targeting approach also allows us to study very clearly a newly recognized effect of radiation, the ''bystander effect'', which appears to dominate some low-dose responses and therefore may have a significant role in low-dose risk mechanisms. Our project also addresses the concept that the background of naturally occurring oxidative damage that takes place continually in cells due to byproducts of metabolism may play a role in treatments that modify the levels of oxidative damage, either alone or in combination with low-dose irradiation. In this project, we have used human and rodent cell lines and each set of experiments has been carried out on a single cell type. However, low-dose research has to extend into tissues because signaling between cells of different types is likely to influence the responses. Our studies have therefore also included microbeam experiments using a model tissue system that consists of an explant of a small piece of pig ureter grown in culture. The structure of this tissue is similar to that of epithelium and there it relates to the tissues in which carcinoma arises. Our studies have been able to measure bystander-induced changes in the cells growing out from the tissue fragment after it has been targeted with a few radiation tracks to mimic a low-dose exposure.« less
Near-Infrared Monitoring of Model Chronic Compartment Syndrome In Exercising Skeletal Muscle
NASA Technical Reports Server (NTRS)
Hargens, Alan R.; Breit, G. A.; Gross, J. H.; Watenpaugh, D. E.; Chance, B.
1995-01-01
Chronic compartment syndrome (CCS) is characterized by muscle ischemia, usually in the anterior oompartment of the leg, caused by high intramuscular pressure during exercise. Dual-wave near-infrared (NIR) spectroscopy is an optical technique that allows noninvasive tracking of variations in muscle tissue oxygenation (Chance et al., 1988). We hypothesized that with a model CCS, muscle tissue oxygenation will show a greater decline during exercise and a slower recovery post-exercise than under normal conditions.
Schadow, Gunther; Dhaval, Rakesh; McDonald, Clement J; Ragg, Susanne
2006-01-01
We present the architecture and approach of an evolving campus-wide information service for tissues with clinical and data annotations to be used and contributed to by clinical researchers across the campus. The services provided include specimen tracking, long term data storage, and computational analysis services. The project is conceived and sustained by collaboration among researchers on the campus as well as participation in standards organizations and national collaboratives.
QUANTITATIVE PLUTONIUM MICRODISTRIBUTION IN BONE TISSUE OF VERTEBRA FROM A MAYAK WORKER
Lyovkina, Yekaterina V.; Miller, Scott C.; Romanov, Sergey A.; Krahenbuhl, Melinda P.; Belosokhov, Maxim V.
2010-01-01
The purpose was to obtain quantitative data on plutonium microdistribution in different structural elements of human bone tissue for local dose assessment and dosimetric models validation. A sample of the thoracic vertebra was obtained from a former Mayak worker with a rather high plutonium burden. Additional information was obtained on occupational and exposure history, medical history, and measured plutonium content in organs. Plutonium was detected in bone sections from its fission tracks in polycarbonate film using neutron-induced autoradiography. Quantitative analysis of randomly selected microscopic fields on one of the autoradiographs was performed. Data included fission fragment tracks in different bone tissue and surface areas. Quantitative information on plutonium microdistribution in human bone tissue was obtained for the first time. From these data, quantitative relationship of plutonium decays in bone volume to decays on bone surface in cortical and trabecular fractions were defined as 2.0 and 0.4, correspondingly. The measured quantitative relationship of decays in bone volume to decays on bone surface does not coincide with recommended models for the cortical bone fraction by the International Commission on Radiological Protection. Biokinetic model parameters of extrapulmonary compartments might need to be adjusted after expansion of the data set on quantitative plutonium microdistribution in other bone types in human as well as other cases with different exposure patterns and types of plutonium. PMID:20838087
Boyle, John J.; Kume, Maiko; Wyczalkowski, Matthew A.; Taber, Larry A.; Pless, Robert B.; Xia, Younan; Genin, Guy M.; Thomopoulos, Stavros
2014-01-01
When mechanical factors underlie growth, development, disease or healing, they often function through local regions of tissue where deformation is highly concentrated. Current optical techniques to estimate deformation can lack precision and accuracy in such regions due to challenges in distinguishing a region of concentrated deformation from an error in displacement tracking. Here, we present a simple and general technique for improving the accuracy and precision of strain estimation and an associated technique for distinguishing a concentrated deformation from a tracking error. The strain estimation technique improves accuracy relative to other state-of-the-art algorithms by directly estimating strain fields without first estimating displacements, resulting in a very simple method and low computational cost. The technique for identifying local elevation of strain enables for the first time the successful identification of the onset and consequences of local strain concentrating features such as cracks and tears in a highly strained tissue. We apply these new techniques to demonstrate a novel hypothesis in prenatal wound healing. More generally, the analytical methods we have developed provide a simple tool for quantifying the appearance and magnitude of localized deformation from a series of digital images across a broad range of disciplines. PMID:25165601
Ultrasound Imaging in Radiation Therapy: From Interfractional to Intrafractional Guidance
Western, Craig; Hristov, Dimitre
2015-01-01
External beam radiation therapy (EBRT) is included in the treatment regimen of the majority of cancer patients. With the proliferation of hypofractionated radiotherapy treatment regimens, such as stereotactic body radiation therapy (SBRT), interfractional and intrafractional imaging technologies are becoming increasingly critical to ensure safe and effective treatment delivery. Ultrasound (US)-based image guidance systems offer real-time, markerless, volumetric imaging with excellent soft tissue contrast, overcoming the limitations of traditional X-ray or computed tomography (CT)-based guidance for abdominal and pelvic cancer sites, such as the liver and prostate. Interfractional US guidance systems have been commercially adopted for patient positioning but suffer from systematic positioning errors induced by probe pressure. More recently, several research groups have introduced concepts for intrafractional US guidance systems leveraging robotic probe placement technology and real-time soft tissue tracking software. This paper reviews various commercial and research-level US guidance systems used in radiation therapy, with an emphasis on hardware and software technologies that enable the deployment of US imaging within the radiotherapy environment and workflow. Previously unpublished material on tissue tracking systems and robotic probe manipulators under development by our group is also included. PMID:26180704
High-resolution nitrogen stable isotope sclerochronology of bivalve shell carbonate-bound organics
NASA Astrophysics Data System (ADS)
Gillikin, David P.; Lorrain, Anne; Jolivet, Aurélie; Kelemen, Zita; Chauvaud, Laurent; Bouillon, Steven
2017-03-01
Nitrogen stable isotope ratios (δ15N) of organic material have successfully been used to track food-web dynamics, nitrogen baselines, pollution, and nitrogen cycling. Extending the δ15N record back in time has not been straightforward due to a lack of suitable substrates in which δ15N records are faithfully preserved, thus sparking interest in utilizing skeletal carbonate-bound organic matter (CBOM) in mollusks, corals, and foraminifera. Here we test if calcite Pecten maximus shells from the Bay of Brest and the French continental shelf can be used as an archive of δ15N values over a large environmental gradient and at a high temporal resolution (approximately weekly). Bulk CBOM δ15N values from the growing tip of shells collected over a large nitrogen isotope gradient were strongly correlated with adductor muscle tissue δ15N values (R2 = 0.99, n = 6, p < 0.0001). We were able to achieve weekly resolution (on average) over the growing season from sclerochronological profiles of three shells, which showed large seasonal variations up to 3.4‰. However, there were also large inter-specimen differences (up to 2.5‰) between shells growing at the same time and location. Generally, high-resolution shell δ15N values follow soft-tissue δ15N values, but soft-tissues integrate more time, hence soft-tissue data are more time-averaged and smoothed. Museum-archived shells from the 1950s, 1965, and 1970s do not show a large difference in δ15N values through time despite expected increasing N loading to the Bay over this time, which could be due to anthropogenic N sources with contrasting values. Compiling shell CBOM δ15N data from several studies suggests that the offset between soft-tissue and shell δ15N values (Δtissue-shell) differs between calcite and aragonite shells. We hypothesize that this difference is caused by differences in amino acids used in constructing the different minerals, which should be specific to the CaCO3 polymorph being constructed. Future work should use compound specific isotope analyses (CSIA) to test this hypothesis, and to determine whether certain amino acids could specifically track N sources or possibly identify amino acids that are more resistant to diagenesis in fossil shells. In conclusion, bivalve shell CBOM δ15N values can be used in a similar manner to soft-tissue δ15N values, and can track various biogeochemical events at a very high-resolution.
Gwosch, K; Hartmann, B; Jakubek, J; Granja, C; Soukup, P; Jäkel, O; Martišíková, M
2013-06-07
Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient's geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations in the beam width could be measured with a precision of 0.9 mm. Furthermore, shifts of the lateral beam position could be monitored with a sub-millimetre precision. The presented investigations demonstrate experimentally that the non-invasive measurement and analysis of secondary ion distributions around head-sized homogeneous objects provide information on the actual beam delivery. Beam range, width and position could be monitored with a precision attractive for therapeutic situations.
NASA Technical Reports Server (NTRS)
Cruty, M. R.; Benton, E. V.; Turnbill, C. E.; Philpott, D. E.
1975-01-01
Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.
Bellaïche, Yohanns; Bosveld, Floris; Graner, François; Mikula, Karol; Remesíková, Mariana; Smísek, Michal
2011-01-01
In this paper, we present a novel algorithm for tracking cells in time lapse confocal microscopy movie of a Drosophila epithelial tissue during pupal morphogenesis. We consider a 2D + time video as a 3D static image, where frames are stacked atop each other, and using a spatio-temporal segmentation algorithm we obtain information about spatio-temporal 3D tubes representing evolutions of cells. The main idea for tracking is the usage of two distance functions--first one from the cells in the initial frame and second one from segmented boundaries. We track the cells backwards in time. The first distance function attracts the subsequently constructed cell trajectories to the cells in the initial frame and the second one forces them to be close to centerlines of the segmented tubular structures. This makes our tracking algorithm robust against noise and missing spatio-temporal boundaries. This approach can be generalized to a 3D + time video analysis, where spatio-temporal tubes are 4D objects.
Alfano, Robert R.; Tang, Jing; Evans, Jonathan M.; Ho, Peng Pei
2006-04-25
Laser tissue welding can be achieved using tunable Cr.sup.4+ lasers, semiconductor lasers and fiber lasers, where the weld strength follows the absorption spectrum of water. The use of gelatin and esterified gelatin as solders in conjunction with laser inducted tissue welding impart much stronger tensile and torque strengths than albumin solders. Selected NIR wavelength from the above lasers can improve welding and avoid thermal injury to tissue when used alone or with gelatin and esterified gelatin solders. These discoveries can be used to enhance laser tissue welding of tissues such as skin, mucous, bone, blood vessel, nerve, brain, liver, pancreas, spleen, kidney, lung, bronchus, respiratory track, urinary tract, gastrointestinal tract, or gynecologic tract and as a sealant for pulmonary air leaks and fistulas such as intestinal, rectal and urinary fistulas.
Affinity-based strategies to fast track development of colon cancer biomarkers — EDRN Public Portal
Our goal is to discover plasma and tissue-based tumor biomarkers that work well enough together to identity colon cancer at early stages, lead to accurate diagnosis and could ultimately allow for individualized treatment.
Remote ultrasound palpation for robotic interventions using absolute elastography.
Schneider, Caitlin; Baghani, Ali; Rohling, Robert; Salcudean, Septimiu
2012-01-01
Although robotic surgery has addressed many of the challenges presented by minimally invasive surgery, haptic feedback and the lack of knowledge of tissue stiffness is an unsolved problem. This paper presents a system for finding the absolute elastic properties of tissue using a freehand ultrasound scanning technique, which utilizes the da Vinci Surgical robot and a custom 2D ultrasound transducer for intraoperative use. An external exciter creates shear waves in the tissue, and a local frequency estimation method computes the shear modulus. Results are reported for both phantom and in vivo models. This system can be extended to any 6 degree-of-freedom tracking method and any 2D transducer to provide real-time absolute elastic properties of tissue.
Stefanopoulos, P K; Filippakis, K; Soupiou, O T; Pazarakiotis, V C
2014-12-01
Firearm-related injuries are caused by a wide variety of weapons and projectiles. The kinetic energy of the penetrating projectile defines its ability to disrupt and displace tissue, whereas the actual tissue damage is determined by the mode of energy release during the projectile-tissue interaction and the particular characteristics of the tissues and organs involved. Certain projectile factors, namely shape, construction, and stability, greatly influence the rate of energy transfer to the tissues along the wound track. Two zones of tissue damage can be identified, the permanent cavity created by the passage of the bullet and a potential area of contused tissue surrounding it, produced mainly by temporary cavitation which is a manifestation of effective high-energy transfer to tissue. Due to the complex nature of these injuries, wound assessment and the type and extent of treatment required should be based on an understanding of the various mechanisms contributing to tissue damage. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Furdella, Kenneth J.; Witte, Russell S.; Vande Geest, Jonathan P.
2017-04-01
Although the drug-eluting stent (DES) has dramatically reduced the rate of coronary restenosis, it still occurs in up to 20% of patients with a DES. Monitoring drug delivery could be one way to decrease restenosis rates. We demonstrate real-time photoacoustic imaging and spectroscopy (PAIS) using a wavelength-tunable visible laser and clinical ultrasound scanner to track cardiac drug delivery. The photoacoustic signal was initially calibrated using porcine myocardial samples soaked with a known concentration of a drug surrogate (DiI). Next, an in situ coronary artery was perfused with DiI for 20 min and imaged to monitor dye transport in the tissue. Finally, a partially DiI-coated stent was inserted into the porcine brachiocephalic trunk for imaging. The photoacoustic signal was proportional to the DiI concentration between 2.4 and 120 μg/ml, and the dye was detected over 1.5 mm from the targeted coronary vessel. Photoacoustic imaging was also able to differentiate the DiI-coated portion of the stent from the uncoated region. These results suggest that PAIS can track drug delivery to cardiac tissue and detect drugs loaded onto a stent with sub-mm precision. Future work using PAIS may help improve DES design and reduce the probability of restenosis.
Poludniowski, Gavin; Webb, Steve; Evans, Philip M
2012-03-01
Artifacts in treatment-room cone-beam reconstructions have been observed at the authors' center when cone-beam acquisition is simultaneous with radio frequency (RF) transponder tracking using the Calypso 4D system (Calypso Medical, Seattle, WA). These artifacts manifest as CT-number modulations and increased CT-noise. The authors present a method for the suppression of the artifacts. The authors propose a three-stage postprocessing technique that can be applied to image volumes previously reconstructed by a cone-beam system. The stages are (1) segmentation of voxels into air, soft-tissue, and bone; (2) application of a 2D spatial-filter in the axial plane to the soft-tissue voxels; and (3) normalization to remove streaking along the axial-direction. The algorithm was tested on patient data acquired with Synergy XVI cone-beam CT systems (Elekta, Crawley, United Kingdom). The computational demands of the suggested correction are small, taking less than 15 s per cone-beam reconstruction on a desktop PC. For a moderate loss of spatial-resolution, the artifacts are strongly suppressed and low-contrast visibility is improved. The correction technique proposed is fast and effective in removing the artifacts caused by simultaneous cone-beam imaging and RF-transponder tracking.
Control of a HexaPOD treatment couch for robot-assisted radiotherapy.
Hermann, Christian; Ma, Lei; Wilbert, Jürgen; Baier, Kurt; Schilling, Klaus
2012-10-01
Moving tumors, for example in the vicinity of the lungs, pose a challenging problem in radiotherapy, as healthy tissue should not be irradiated. Apart from gating approaches, one standard method is to irradiate the complete volume within which a tumor moves plus a safety margin containing a considerable volume of healthy tissue. This work deals with a system for tumor motion compensation using the HexaPOD® robotic treatment couch (Medical Intelligence GmbH, Schwabmünchen, Germany). The HexaPOD, carrying the patient during treatment, is instructed to perform translational movements such that the tumor motion, from the beams-eye view of the linear accelerator, is eliminated. The dynamics of the HexaPOD are characterized by time delays, saturations, and other non-linearities that make the design of control a challenging task. The focus of this work lies on two control methods for the HexaPOD that can be used for reference tracking. The first method uses a model predictive controller based on a model gained through system identification methods, and the second method uses a position control scheme useful for reference tracking. We compared the tracking performance of both methods in various experiments with real hardware using ideal reference trajectories, prerecorded patient trajectories, and human volunteers whose breathing motion was compensated by the system.
Noar, Joe; Woods, Eva; Hodgson, Tim
2015-03-01
Whilst transient effects of orthodontic appliances on the oral mucosa are well recognized, chronic lesions, persisting post therapy are unusual. We describe a persistent lingual mucosal defect related to a transpalatal arch (TPA) in a healthy 19-year-old female. The asymptomatic lesion is presently being monitored, however, surgical revision in the future may be requested by the patient if the area fails to remodel. Clinical Relevance: Soft tissue trauma to the tongue by anchorage reinforcing appliances may result in long-term effects that could require surgical management.
2010-01-01
Background Managing change has not only been recognized as an important topic in medical informatics, but it has become increasingly important in translational informatics. The move to share data, together with the increasing complexity and volume of the data, has precipitated a transition from locally stored worksheet and flat files to relational data bases with object oriented interfaces for data storage and retrieval. While the transition from simple to complex data structures, mirroring the transition from simple to complex experimental technologies, seems natural, the human factor often fails to be adequately addressed leading to failures in managing change. Methods We describe here a case study in change management applied to an application in translational informatics that touches upon changes in hardware, software, data models, procedures, and terminology standards. We use the classic paper by Riley and Lorenzi to dissect the problems that arose, the solutions that were implemented, and the lessons learned. Results The entire project from requirements gathering through completion of migration of the system took three years. Double data entry into the old and new systems persisted for six months. Contributing factors hindering progress and solutions to facilitate managing the change were identified in seven of the areas identified by Riley and Lorenzi: communications, cultural changes in work practice, scope creep, leadership and organizational issues, and training. Conclusions Detailed documentation of the agreed upon requirements for the new system along with ongoing review of the sources of resistance to change as defined by Riley and Lorenzi were the most important steps taken that contributed to the success of the project. Cultural changes in tissue collection mandated by standards requirements introduced by the Cancer Bioinformatics Grid (CaBIG®) and excessive reliance on the outgoing system during a lengthy period of dual data entry were the primary sources of resistance to change. PMID:20525187
Edgerton, Mary E; Grizzle, William E; Washington, M Kay
2010-06-02
Managing change has not only been recognized as an important topic in medical informatics, but it has become increasingly important in translational informatics. The move to share data, together with the increasing complexity and volume of the data, has precipitated a transition from locally stored worksheet and flat files to relational data bases with object oriented interfaces for data storage and retrieval. While the transition from simple to complex data structures, mirroring the transition from simple to complex experimental technologies, seems natural, the human factor often fails to be adequately addressed leading to failures in managing change. We describe here a case study in change management applied to an application in translational informatics that touches upon changes in hardware, software, data models, procedures, and terminology standards. We use the classic paper by Riley and Lorenzi to dissect the problems that arose, the solutions that were implemented, and the lessons learned. The entire project from requirements gathering through completion of migration of the system took three years. Double data entry into the old and new systems persisted for six months. Contributing factors hindering progress and solutions to facilitate managing the change were identified in seven of the areas identified by Riley and Lorenzi: communications, cultural changes in work practice, scope creep, leadership and organizational issues, and training. Detailed documentation of the agreed upon requirements for the new system along with ongoing review of the sources of resistance to change as defined by Riley and Lorenzi were the most important steps taken that contributed to the success of the project. Cultural changes in tissue collection mandated by standards requirements introduced by the Cancer Bioinformatics Grid (CaBIG) and excessive reliance on the outgoing system during a lengthy period of dual data entry were the primary sources of resistance to change.
Hascup, Erin R.; Bjerkén, Sara af; Hascup, Kevin N.; Pomerleau, Francois; Huettl, Peter; Strömberg, Ingrid; Gerhardt, Greg A.
2010-01-01
Chronic implantation of neurotransmitter measuring devices is essential for awake, behavioral studies occurring over multiple days. Little is known regarding the effects of long term implantation on surrounding brain parenchyma and the resulting alterations in the functional properties of this tissue. We examined the extent of tissue damage produced by chronic implantation of either ceramic microelectrode arrays (MEAs) or microdialysis probes. Histological studies were carried out on fixed tissues using stains for neurons (cresyl violet), astrocytes (GFAP), microglia (Iba-1), glutamatergic nerve fibers (VGLUT1), and the blood-brain barrier (SMI-71). Nissl staining showed pronounced tissue body loss with microdialysis implants compared to MEAs. The MEAs produced mild gliosis extending 50–100 µm from the tracks, with a significant change in the affected areas starting at 3 days. By contrast, the microdialysis probes produced gliosis extending 200–300 µm from the track, which was significant at 3 and 7 days. Markers for microglia and glutamatergic fibers supported that the MEAs produce minimal damage with significant changes occurring only at 3 and 7 days that return to control levels by one month. SMI-71 staining supported integrity of the blood brain barrier out to 1 week for both the microdialysis probes and the MEAs. This data support that the ceramic MEAs small size and biocompatibility are necessary to accurately measure neurotransmitter levels in the intact brain. The minimal invasiveness of the MEAs reduce tissue loss, allowing for long term (>6 month) electrochemical and electrophysiological monitoring of brain activity. PMID:19577548
Ricci, Joseph A; Vargas, Christina R; Ho, Olivia A; Lin, Samuel J; Tobias, Adam M; Lee, Bernard T
2017-07-01
Postoperative free flap care has historically required intensive monitoring for 24 hours in an intensive care unit. Continuous monitoring with tissue oximetry has allowed earlier detection of vascular compromise, decreasing flap loss and improving salvage. This study aims to identify whether a fast-track postoperative paradigm can be safely used with tissue oximetry to decrease intensive monitoring and costs. All consecutive microsurgical breast reconstructions performed at a single institution were reviewed (2008-2014) and cases requiring return to the operating room were identified. Data evaluated included patient demographics, the take back time course, and complications of flap loss and salvage. A cost-benefit analysis was performed to analyse the utility of a postoperative intensive monitoring setting. There were 900 flaps performed and 32 required an unplanned return to the operating room. There were 16 flaps that required a reexploration within the first 24 hours; the standard length of intensive unit monitoring. After 4 hours, there were 7 flaps (44%) detected by tissue oximetry for reexploration. After 15 hours of intensive monitoring postoperatively, cost analysis revealed that the majority (15/16; 94%) of failing flaps had been identified and the cost of identifying each subsequent failing flap exceeded the cost of another hour of intensive monitoring. The postoperative paradigm for microsurgical flaps has historically required intensive unit monitoring. Using tissue oximetry, a fast-track pathway can reduce time spent in an intensive monitoring setting from 24 to 15 hours with significant cost savings and minimal risk of missing a failing free flap.
DeRose, Yoko S.; Gligorich, Keith M.; Wang, Guoying; Georgelas, Ann; Bowman, Paulette; Courdy, Samir J.; Welm, Alana L.; Welm, Bryan E.
2013-01-01
Research models that replicate the diverse genetic and molecular landscape of breast cancer are critical for developing the next generation therapeutic entities that can target specific cancer subtypes. Patient-derived tumorgrafts, generated by transplanting primary human tumor samples into immune-compromised mice, are a valuable method to model the clinical diversity of breast cancer in mice, and are a potential resource in personalized medicine. Primary tumorgrafts also enable in vivo testing of therapeutics and make possible the use of patient cancer tissue for in vitro screens. Described in this unit are a variety of protocols including tissue collection, biospecimen tracking, tissue processing, transplantation, and 3-dimensional culturing of xenografted tissue, that enable use of bona fide uncultured human tissue in designing and validating cancer therapies. PMID:23456611
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
... March 31, 2011. Period to be reviewed Antidumping Duty Proceedings Brazil: Certain Hot-Rolled Carbon... People's Republic of China: Certain Tissue Paper Products \\3\\ A-570-894...... 3/1/09-2/28/10 Fujian Provincial Shaowu City Huaguang Special Craft Co., Ltd. Max Fortune Industrial Limited Max Fortune (FZ) Paper...
An Introduction to The Royan Human Ovarian Tissue Bank.
Abtahi, Naeimeh Sadat; Ebrahimi, Bita; Fathi, Rouhollah; Khodaverdi, Sepideh; Mehdizadeh Kashi, Abolfazl; Valojerdi, Mojtaba Rezazadeh
2016-01-01
From December 2000 until 2010, the researchers at Royan Institute conducted a wide range of investigations on ovarian tissue cryopreservation with the intent to provide fertility pres- ervation to cancer patients that were considered to be candidates for these services. In 2010, Royan Institute established the Royan Human Ovarian Tissue Bank as a subgroup of the Embryology Department. Since its inception, approximately 180 patients between the ages of 747 years have undergone consultations. Ovarian samples were cryopreserved from 47 patients (age: 7-35 years) diagnosed with cervical adenocarcinoma (n=9); breast carcinoma (n=7), Ewing's sarcoma (n=7), opposite side ovarian tumor (n=7), endometrial adenocarci- noma (n=4), malignant colon tumors (n=3), as well as Hodgkin's lymphoma, major thalas- semia and acute lymphoblastic leukemia (n=1-2 patients for each disease). Additionally, two patients requested ovarian tissue transplantation after completion of their treatments.
Baumann, Michael; Mozer, Pierre; Daanen, Vincent; Troccaz, Jocelyne
2007-01-01
The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make post-interventional quality controls possible. Since the patient is not immobilized, since the prostate is mobile and due to the fact that probe movements are only constrained by the rectum during biopsy acquisition, the tracking system must be able to estimate rigid transformations that are beyond the capture range of common image similarity measures. We propose a fast and robust multi-resolution attribute-vector registration approach that combines global and local optimization methods to solve this problem. Global optimization is performed on a probe movement model that reduces the dimensionality of the search space and thus renders optimization efficient. The method was tested on 237 prostate volumes acquired from 14 different patients for 3D to 3D and 3D to orthogonal 2D slices registration. The 3D-3D version of the algorithm converged correctly in 96.7% of all cases in 6.5s with an accuracy of 1.41mm (r.m.s.) and 3.84mm (max). The 3D to slices method yielded a success rate of 88.9% in 2.3s with an accuracy of 1.37mm (r.m.s.) and 4.3mm (max).
Jaeger, Audrey; Lecomte, Vincent J; Weimerskirch, Henri; Richard, Pierre; Cherel, Yves
2010-12-15
Stable isotopes are increasingly being used to trace wildlife movements. A fundamental prerequisite of animal isotopic tracking is a good knowledge of spatial isotopic variations in the environment. Few accessible reference maps of the isotopic landscape ("isoscapes") are available for marine predators. Here, we validate for the first time an isotopic gradient for higher trophic levels by using a unique combination of a large number of satellite-tracks and subsequent blood plasma isotopic signatures from a wide-ranging oceanic predator. The plasma δ(13)C and δ(15)N values of wandering albatrosses (n = 45) were highly and positively correlated to the Southern Ocean latitudes at which the satellite-tracked individuals foraged. The well-defined latitudinal baseline carbon isoscapes in the Southern Ocean is thus reflected in the tissue of consumers, but with a positive shift due to the cumulative effect of a slight (13)C-enrichment at each trophic level. The data allowed us to estimate the carbon isotopic position of the main oceanic fronts in the area, and thus to delineate robust isoscapes of the main foraging zones for top predators. The plasma δ(13)C and δ(15)N values were positively and linearly correlated, thus suggesting that latitudinal isoscapes also occur for δ(15)N at the base of the food web in oceanic waters of the Southern Ocean. The combination of device deployments with sampling of relevant tissues for isotopic analysis appears to be a powerful tool for investigating consumers' isoscapes at various spatio-temporal scales. Copyright © 2010 John Wiley & Sons, Ltd.
Telomere tracking from birth to adulthood and residential traffic exposure.
Bijnens, Esmée M; Zeegers, Maurice P; Derom, Catherine; Martens, Dries S; Gielen, Marij; Hageman, Geja J; Plusquin, Michelle; Thiery, Evert; Vlietinck, Robert; Nawrot, Tim S
2017-11-21
Telomere attrition is extremely rapid during the first years of life, while lifestyle during adulthood exerts a minor impact. This suggests that early life is an important period in the determination of telomere length. We investigated the importance of the early-life environment on both telomere tracking and adult telomere length. Among 184 twins of the East Flanders Prospective Twin Survey, telomere length in placental tissue and in buccal cells in young adulthood was measured. Residential addresses at birth and in young adulthood were geocoded and residential traffic and greenness exposure was determined. We investigated individual telomere tracking from birth over a 20 year period (mean age (SD), 22.6 (3.1) years) in association with residential exposure to traffic and greenness. Telomere length in placental tissue and in buccal cells in young adulthood correlated positively (r = 0.31, P < 0.0001). Persons with higher placental telomere length at birth were more likely to have a stronger downward shift in telomere ranking over life (P < 0.0001). Maternal residential traffic exposure correlated inversely with telomere length at birth. Independent of birth placental telomere length, telomere ranking between birth and young adulthood was negatively and significantly associated with residential traffic exposure at the birth address, while traffic exposure at the residential address at adult age was not associated with telomere length. Longitudinal evidence of telomere length tracking from birth to adulthood shows inverse associations of residential traffic exposure in association with telomere length at birth as well as accelerated telomere shortening in the first two decades of life.
Improvements in multimedia data buffering using master/slave architecture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheikh, S.; Ganesan, R.
1996-12-31
Advances in the networking technology and multimedia technology has necessitated a need for multimedia servers to be robust and reliable. Existing solutions have direct limitations such as I/O bottleneck and reliability of data retrieval. The system can store the stream of incoming data if enough buffer space is available or the mass storage is clearing the buffer data faster than queue input. A single buffer queue is not sufficient to handle the large frames. Queue sizes are normally several megabytes in length and thus in turn will introduce a state of overflow. The system should also keep track of themore » rewind, fast forwarding, and pause requests, otherwise queue management will become intricate. In this paper, we present a master/slave (server that is designated to monitor the workflow of the complete system. This server holds every other information of slaves by maintaining a dynamic table. It also controls the workload on each of the systems by redistributing request to others or handles the request by itself) approach which will overcome the limitations of today`s storage and also satisfy tomorrow`s storage needs. This approach will maintain the system reliability and yield faster response by using more storage units in parallel. A network of master/slave can handle many requests and synchronize them at all times. Using dedicated CPU and a common pool of queues we explain how queues can be controlled and buffer overflow can be avoided. We propose a layered approach to the buffering problem and provide a read-ahead solution to ensure continuous storage and retrieval of multimedia data.« less
Spatially coordinated dynamic gene transcription in living pituitary tissue
Featherstone, Karen; Hey, Kirsty; Momiji, Hiroshi; McNamara, Anne V; Patist, Amanda L; Woodburn, Joanna; Spiller, David G; Christian, Helen C; McNeilly, Alan S; Mullins, John J; Finkenstädt, Bärbel F; Rand, David A; White, Michael RH; Davis, Julian RE
2016-01-01
Transcription at individual genes in single cells is often pulsatile and stochastic. A key question emerges regarding how this behaviour contributes to tissue phenotype, but it has been a challenge to quantitatively analyse this in living cells over time, as opposed to studying snap-shots of gene expression state. We have used imaging of reporter gene expression to track transcription in living pituitary tissue. We integrated live-cell imaging data with statistical modelling for quantitative real-time estimation of the timing of switching between transcriptional states across a whole tissue. Multiple levels of transcription rate were identified, indicating that gene expression is not a simple binary ‘on-off’ process. Immature tissue displayed shorter durations of high-expressing states than the adult. In adult pituitary tissue, direct cell contacts involving gap junctions allowed local spatial coordination of prolactin gene expression. Our findings identify how heterogeneous transcriptional dynamics of single cells may contribute to overall tissue behaviour. DOI: http://dx.doi.org/10.7554/eLife.08494.001 PMID:26828110
Chung, Eunna; Nam, Seung Yun; Ricles, Laura M; Emelianov, Stanislav Y; Suggs, Laura J
2013-01-01
Evaluating the regenerative capacity of a tissue-engineered device in a noninvasive and synchronous manner is critical to determining the mechanisms for success in clinical applications. In particular, directly tracking implanted cells in a three-dimensional (3D) scaffold is desirable in that it enables the monitoring of cellular activity in a specific and localized manner. The authors’ group has previously demonstrated that the PEGylation of fibrin results in a 3D scaffold that supports morphologic and phenotypic changes in mesenchymal stem cells that may be advantageous in wound healing applications. Recently, the authors have evaluated adipose-derived stem cells (ASCs) as a mesenchymal cell source to regenerate skin and blood vessels due to their potential for proliferation, differentiation, and production of growth factors. However, tracking and monitoring ASCs in a 3D scaffold, such as a PEGylated fibrin gel, have not yet been fully investigated. In the current paper, nanoscale gold spheres (20 nm) as cell tracers for ASCs cultured in a PEGylated fibrin gel were evaluated. An advanced dual-imaging modality combining ultrasound and photoacoustic imaging was utilized to monitor rat ASCs over time. The ASCs took up gold nanotracers and could be detected up to day 16 with high sensitivity using photoacoustic imaging. There were no detrimental effects on ASC morphology, network formation, proliferation, and protein expression/secretion (ie, smooth muscle α-actin, vascular endothelial growth factor, matrix metalloproteinase-2, and matrix metalloproteinase-9) associated with gold nanotracers. Therefore, utilization of gold nanotracers can be an effective strategy to monitor the regenerative process of a stem cell source in a 3D gel for vascular and dermal tissue engineering applications. PMID:23345978