Nuclear medicine in clinical neurology: an update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oldendorf, W.H.
1981-01-01
Isotope scanning using technetium 99m pertechnetate has fallen into disuse since the advent of x-ray computerized tomography. Regional brain blood flow studies have been pursued on a research basis. Increased regional blood flow during focal seizure activity has been demonstrated and is of use in localizing such foci. Cisternography as a predictive tool in normal pressure hydrocephalus is falling into disuse. Positron tomographic scanning is a potent research tool that can demonstrate both regional glycolysis and blood flow. Unfortunately, it is extremely expensive and complex to apply in a clinical setting. With support from the National Institutes of Health, sevenmore » extramural centers have been funded to develop positron tomographic capabilities, and they will greatly advance our knowledge of stroke pathophysiology, seizure disorders, brain tumors, and various degenerative diseases. Nuclear magnetic resonance imaging is a potentially valuable tool since it creates tomographic images representing the distribution of brain water. No tissue ionization is produced, and images comparable to second-generation computerized tomographic scans are already being produced in humans.« less
ERIC Educational Resources Information Center
Damasio, Antonio R., Damasio, Hanna
1992-01-01
Discusses the advances made in understanding the brain structures responsible for language. Presents findings made using magnetic resonance imaging (MRI) and positron emission tomographic (PET) scans to study brain activity. These findings map the structures in the brain that manipulate concepts and those that turn concepts into words. (MCO)
Murder, insanity, and medical expert witnesses.
Ciccone, J R
1992-06-01
Recent advances in the ability to study brain anatomy and function and attempts to link these findings with human behavior have captured the attention of the legal system. This had led to the increasing use of the "neurological defense" to support a plea of not guilty by reason of insanity. This article explores the history of the insanity defense and explores the role of the medical expert witnesses in integrating clinical and laboratory findings, eg, computed tomographic scans, magnetic resonance scans, and single-photon emission computed tomographic scans. Three cases involving murder and brain dysfunction are discussed: the first case involves a subarachnoid hemorrhage resulting in visual perceptual and memory impairment; the second case, a diagnosis of Alzheimer's disease; and the third case, the controverted diagnosis of complex partial seizures in a serial killer.
2015-05-18
Head computed tomographic scan most commonly found skull fracture (68.9%), subdural hematoma (54.1%), and cerebral contusion (51.4%). Hypertonic saline...were common on presentation. Head computed tomographic scan most commonly found skull fracture (68.9%), subdural hematoma (54.1%), and cerebral con...reported was skull fracture, occurring in 68.9% of patients. The most common type of intracranial hemorrhage was subdural hematoma (54.1%). Multiple
Childhood Psychosis and Computed Tomographic Brain Scan Findings.
ERIC Educational Resources Information Center
Gillberg, Christopher; Svendsen, Pal
1983-01-01
Computerized tomography (CT) of the brain was used to examine 27 infantile autistic children, 9 children with other kinds of childhood psychoses, 23 children with mental retardation, and 16 normal children. Gross abnormalities were seen in 26 percent of the autism cases. (Author/SEW)
Lew, Henry L; Lee, Eun Ha; Miyoshi, Yasushi; Chang, Douglas G; Date, Elaine S; Jerger, James F
2004-03-01
Because of the violent nature of traumatic brain injury, traumatic brain injury patients are susceptible to various types of trauma involving the auditory system. We report a case of a 55-yr-old man who presented with communication problems after traumatic brain injury. Initial results from behavioral audiometry and Weber/Rinne tests were not reliable because of poor cooperation. He was transferred to our service for inpatient rehabilitation, where review of the initial head computed tomographic scan showed only left temporal bone fracture. Brainstem auditory-evoked potential was then performed to evaluate his hearing function. The results showed bilateral absence of auditory-evoked responses, which strongly suggested bilateral deafness. This finding led to a follow-up computed tomographic scan, with focus on bilateral temporal bones. A subtle transverse fracture of the right temporal bone was then detected, in addition to the left temporal bone fracture previously identified. Like children with hearing impairment, traumatic brain injury patients may not be able to verbalize their auditory deficits in a timely manner. If hearing loss is suspected in a patient who is unable to participate in traditional behavioral audiometric testing, brainstem auditory-evoked potential may be an option for evaluating hearing dysfunction.
Rehm, C G; Ross, S E
1995-05-01
This article assessed the value of routine head computerized axial tomographic (CT) scans for diagnosis of unsuspected facial fractures and its clinical implications in the multiply injured patient who is intubated, unconscious, or sedated at the time of initial assessment and requires a head CT scan to assess for brain injury. At a level I trauma center from June 1, 1992 to June 1, 1993 all intubated blunt trauma patients who required routine CT scan evaluation at initial assessment were studied prospectively. Routine scanning started at the foramen magnum and included the maxilla. Patients who died within the first 24 hours were excluded. The study population included 116 patients (85 male, 21 female) aged 12 to 85 years (mean, 28 years) with injury severity scores ranging from 1 to 50 (mean, 23). The mechanism of injury was: motor vehicle accidents (n = 74), motorcycling (n = 5), pedestrians accidents (n = 13), falls (n = 10), bicycling (n = 5), assaults (n = 8), and boating accident (n = 1). There were 19 suspected facial fractures; 18 required surgical repair. There were 27 unsuspected facial fractures; 13 required surgical care. Three suspected fractures were ruled out. Routine head CT scans to assess for brain injury in the multiply injured patient are also very useful in the diagnosis of unsuspected facial fractures, almost half of which will require surgical intervention.
Linear Optimization and Image Reconstruction
1994-06-01
final example is again a novel one. We formulate the problem of computer assisted tomographic ( CAT ) image reconstruction as a linear optimization...possibility that a patient, Fred, suffers from a brain tumor. Further, the physician opts to make use of the CAT (Computer Aided Tomography) scan device...and examine the inside of Fred’s head without exploratory surgery. The CAT scan machine works by projecting a finite number of X-rays of known
Atlas of neuroanatomy with radiologic correlation and pathologic illustration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dublin, A.B.; Dublin, W.B.
1982-01-01
This atlas correlates gross neuroanatomic specimens with radiographs and computed tomographic scans. Pathologic specimens and radiographs are displayed in a similar manner. The first chapter, on embryology, shows the development of the telencephalon, diencephalon, mesencephalon, and metencephalon through a series of overlays. The anatomical section shows the surface of the brain, the ventricles and their adjacent structures, and the vascular system. CT anatomy is demonstrated by correlating CT scans with pathologic brain specimens cut in the axial plane. Pathologic changes associated with congenital malformations, injections, injuries, tumors, and other causes are demonstrated in the last six chapters.
Use of radiologic modalities in coccidioidal meningitis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stadalnik, R.C.; Goldstein, E.; Hoeprich, P.D.
1981-01-01
The diagnostic utility of pentetate indium trisodium CSF studies, technetium Tc 99m brain scans, and computerized tomographic (CT) scans was evaluated in eight patients in whom coccidioidal meningitis developed following a dust storm in the Central Valley of California. The 111In flow studies and the CT scans demonstrated hydrocephalus in five patients with clinical findings suggesting this complication. Ventriculitis has not previously been diagnosed before death in patients with coccidioidal meningitis; however, it was demonstrated in two patients by the technetium Tc 99m brain scan. The finding that communicating hydrocephalus occurs early in meningitis and interferes with CSF flow intomore » infected basilar regions has important therapeutic implications in that antifungal agents injected into the lumbar subarachnoid space may not reach these regions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plets, C.; Baert, A.L.; Nijs, G.L.
1986-01-01
It is of the greatest importance to the radiologist, the neurologist and the neurosurgeon to be able to localize topographically a pathological brain process on the CT scan as precisely as possible. For that purpose, the identification of as many anatomical structures as possible on the CT scan image are necessary and indispensable. In this atlas a great number of detailed anatomical data on frontal horizontal CT scan sections, each being only 2 mm thick, are indicated, e.g. the cortical gyri, the basal ganglia, details of the white matter, extracranial muscles and blood vessels, parts of the base and themore » vault of the skull, etc. The very precise topographical description of the numerous CT scan images was realized by the author by confrontation of these images with the corresponding anatomical sections of the same brain specimen, performed by an original technique.« less
Delayed cerebral development in twins with congenital hyperthyroidism.
Kopelman, A E
1983-09-01
Twins had congenital hyperthyroidism and delayed cerebral development manifested as ventriculomegaly, increased space in the interhemispheric fissure, and an exaggerated gyral pattern on cranial computed tomographic scans. At 3 1/2 years of age, both children had delayed development. Fetal and neonatal hyperthyroidism may interfere with normal brain growth and maturation with both neuranatomic and developmental sequelae.
Zanotti-Fregonara, Paolo; Liow, Jeih-San; Comtat, Claude; Zoghbi, Sami S; Zhang, Yi; Pike, Victor W; Fujita, Masahiro; Innis, Robert B
2012-09-01
Image-derived input function (IDIF) from carotid arteries is an elegant alternative to full arterial blood sampling for brain PET studies. However, a recent study using blood-free IDIFs found that this method is particularly vulnerable to patient motion. The present study used both simulated and clinical [11C](R)-rolipram data to assess the robustness of a blood-based IDIF method (a method that is ultimately normalized with blood samples) with regard to motion artifacts. The impact of motion on the accuracy of IDIF was first assessed with an analytical simulation of a high-resolution research tomograph using a numerical phantom of the human brain, equipped with internal carotids. Different degrees of translational (from 1 to 20 mm) and rotational (from 1 to 15°) motions were tested. The impact of motion was then tested on the high-resolution research tomograph dynamic scans of three healthy volunteers, reconstructed with and without an online motion correction system. IDIFs and Logan-distribution volume (VT) values derived from simulated and clinical scans with motion were compared with those obtained from the scans with motion correction. In the phantom scans, the difference in the area under the curve (AUC) for the carotid time-activity curves was up to 19% for rotations and up to 66% for translations compared with the motionless simulation. However, for the final IDIFs, which were fitted to blood samples, the AUC difference was 11% for rotations and 8% for translations. Logan-VT errors were always less than 10%, except for the maximum translation of 20 mm, in which the error was 18%. Errors in the clinical scans without motion correction appeared to be minor, with differences in AUC and Logan-VT always less than 10% compared with scans with motion correction. When a blood-based IDIF method is used for neurological PET studies, the motion of the patient affects IDIF estimation and kinetic modeling only minimally.
Laplante, L; Everett, J
1992-01-01
Many attempts to isolate a dysfunctional site in the brain of schizophrenic patients have converged in a neuropathological conception of the disease based on frontal lobe hypoactivity. Recent data from studies using cytoarchitectony, computerized tomographic scans, cerebral regional blood flow, smooth pursuit eye movements and neuropsychological assessments are discussed. Current data on the hypofrontality hypothesis in schizophrenia seem to suggest an associationist rather than a localisationist perspective of the disorder. PMID:1489762
Scarmeas, Nikolaos; Zarahn, Eric; Anderson, Karen E.; Honig, Lawrence S.; Park, Aileen; Hilton, John; Flynn, Joseph; Sackeim, Harold A.; Stern, Yaakov
2011-01-01
Background Cognitive reserve (CR) is the ability of an individual to cope with advancing brain pathological abnormalities so that he or she remains free of symptoms. Epidemiological data and evidence from positron emission tomography suggest that it may be mediated through education or IQ. Objective To investigate CR-mediated differential brain activation in Alzheimer disease (AD) subjects compared with healthy elderly persons. Participants Using radioactive water positron emission tomography, we scanned 12 AD patients and 17 healthy elderly persons while performing a serial recognition memory task for nonverbalizable shapes under 2 conditions: low demand, in which one shape was presented in each study trial, and titrated demand, in which the study list length was adjusted so that each subject recognized shapes at approximately 75% accuracy. Positron emission tomographic scan acquisition included the encoding and recognition phases. A CR factor score that summarized years of education, National Adult Reading Test estimated IQ, and Wechsler Adult Intelligence Scale–Revised vocabulary subtest score (explaining 71% of the total variance) was used as an index of CR. Voxel-wise, multiple regression analyses were performed with the “activation” difference (titrated demand–low demand) as the dependent variables and the CR factor score as the independent one. Brain regions where regression slopes differed between the 2 groups were identified. Results The slopes were significantly more positive for the AD patients in the left precentral gyrus and in the left hippocampus and significantly more negative in the right fusiform, right middle occipital, left superior occipital, and left middle temporal gyri. Conclusion Brain regions where systematic relationships (slopes) between subjects’ education-IQ and brain activation differ as a function of disease status may mediate the differential ability to cope with (ie, delay or modify) clinical manifestations of AD. PMID:14732623
Lee, Jun Ho; Choi, Hui-Chul; Kim, Chulho; Sohn, Jong Hee; Kim, Heung Cheol
2014-01-01
Necrotizing fasciitis is a soft tissue infection that is characterized by extensive necrosis of the subcutaneous fat, neurovascular structures, and fascia. Cerebral infarction after facial necrotizing fasciitis has been rarely reported. A 61-year-old woman with diabetes was admitted with painful swelling of her right cheek. One day later, she was stuporous and quadriplegic. A computed tomographic scan of her face revealed right facial infection in the periorbital soft tissue, parotid, buccal muscle, and maxillary sinusitis. A computed tomographic scan of the brain revealed cerebral infarction in the right hemisphere, left frontal area, and both cerebellum. Four days later, she died from cerebral edema and septic shock. Involvement of the cerebral vasculature, such as the carotid or vertebral artery by necrotizing fasciitis, can cause cerebral infarction. Facial necrotizing fasciitis should be treated early with surgical treatment and the appropriate antibiotic therapy. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Intravascular lymphomatosis presenting as acute hemispheric dysfunction.
Hwang, Woo Sub; Jung, Chul Won; Ko, Young Hye; Seo, Sang Won; Na, Duk L
2012-11-01
Intravascular lymphomatosis (IVL) is known to affect both hemispheres of the brain and manifests clinically as seizures or dementia. To our knowledge, there have been no cases in which acute hemispheric dysfunction is manifested in IVL. We present a 54-year-old man who showed steroid responsive acute hemispheric dysfunction. A technetium 99m-ethyl cysteinate dimer single-photon emission computed tomographic scan of the brain revealed hypoperfusion in the right hemisphere. The bone marrow biopsy specimen confirmed malignant lymphoid cells in vessels, which suggested IVL. Our case signifies the diversity of clinical manifestations in IVL. Copyright © 2012. Published by Elsevier Inc.
Majidi, Shahram; Rahim, Basit; Gilani, Sarwat I; Gilani, Waqas I; Adil, Malik M; Qureshi, Adnan I
2016-05-01
The evolution of intracerebral hematoma and perihematoma edema in the ultra-early period on computed tomographic (CT) scans in patients with intracerebral hemorrhage (ICH) is not well understood. We aimed to investigate hematoma and perihematoma changes in "neutral brain" models of ICH. One human and five goat cadaveric heads were used as "neutral brains" to provide physical properties of brain without any biological activity or new bleeding. ICH was induced by slow injection of 4 ml of fresh human blood into the right basal ganglia of the goat brains. Similarly, 20 ml of fresh blood was injected deep into the white matter of the human cadaver head in each hemisphere. Serial CT scans of the heads were obtained immediately after hematoma induction and then 1, 3, and 5 hours afterward. Analyze software (AnalyzeDirect, Overland Park, KS, USA) was used to measure hematoma and perihematoma hypodensity volumes in the baseline and follow-up CT scans. The initial hematoma volumes of 11.6 ml and 10.5 ml in the right and left hemispheres of the cadaver brains gradually decreased to 6.6 ml and 5.4 ml at 5 hours, showing 43% and 48% retraction of hematoma, respectively. The volume of the perihematoma hypodensity in the right and left hemisphere increased from 2.6 ml and 2.2 ml in the 1-hour follow-up CT scans to 4.9 ml and 4.4 ml in the 5-hour CT scan, respectively. Hematoma retraction was also observed in all five goat brains ICH models with the mean ICH volume decreasing from 1.49 ml at baseline scan to 1.01 ml at the 5-hour follow-up CT scan (29.6% hematoma retraction). Perihematoma hypodensity was visualized in 70% of ICH in goat brains, with an increasing mean hypodensity volume of 0.4 ml in the baseline CT scan to 0.8 ml in the 5-hour follow-up CT scan. Our study demonstrated that substantial hematoma retraction and perihematoma hypodensity occurs in ICH in the absence of any new bleeding or biological activity of surrounding brain. Such observations suggest that active bleeding is underestimated in patients with no or small hematoma expansion and our understanding of perihematoma hypodensity needs to be reconsidered. Copyright © 2015 by the American Society of Neuroimaging.
NASA Astrophysics Data System (ADS)
Kandel, Mikhail E.; Kouzehgarani, Ghazal N.; Ngyuen, Tan H.; Gillette, Martha U.; Popescu, Gabriel
2017-02-01
Although the contrast generated in transmitted light microscopy is due to the elastic scattering of light, multiple scattering scrambles the image and reduces overall visibility. To image both thin and thick samples, we turn to gradient light interference microscopy (GLIM) to simultaneously measure morphological parameters such as cell mass, volume, and surfaces as they change through time. Because GLIM combines multiple intensity images corresponding to controlled phase offsets between laterally sheared beams, incoherent contributions from multiple scattering are implicitly cancelled during the phase reconstruction procedure. As the interfering beams traverse near identical paths, they remain comparable in power and interfere with optimal contrast. This key property lets us obtain tomographic parameters from wide field z-scans after simple numerical processing. Here we show our results on reconstructing tomograms of bovine embryos, characterizing the time-lapse growth of HeLa cells in 3D, and preliminary results on imaging much larger specimen such as brain slices.
Medical tomograph system using ultrasonic transmission
NASA Technical Reports Server (NTRS)
Heyser, Richard C. (Inventor); Nathan, Robert (Inventor)
1978-01-01
Ultrasonic energy transmission in rectilinear array scanning patterns of soft tissue provides projection density values of the tissue which are recorded as a function of scanning position and angular relationship, .theta., of the subject with a fixed coordinate system. A plurality of rectilinear scan arrays in the same plane for different angular relationships .theta..sub.1 . . . .theta..sub.n thus recorded are superimposed. The superimposition of intensity values thus yields a tomographic image of an internal section of the tissue in the scanning plane.
Low-dose x-ray tomography through a deep convolutional neural network
Yang, Xiaogang; De Andrade, Vincent; Scullin, William; ...
2018-02-07
Synchrotron-based X-ray tomography offers the potential of rapid large-scale reconstructions of the interiors of materials and biological tissue at fine resolution. However, for radiation sensitive samples, there remain fundamental trade-offs between damaging samples during longer acquisition times and reducing signals with shorter acquisition times. We present a deep convolutional neural network (CNN) method that increases the acquired X-ray tomographic signal by at least a factor of 10 during low-dose fast acquisition by improving the quality of recorded projections. Short exposure time projections enhanced with CNN show similar signal to noise ratios as compared with long exposure time projections and muchmore » lower noise and more structural information than low-dose fats acquisition without CNN. We optimized this approach using simulated samples and further validated on experimental nano-computed tomography data of radiation sensitive mouse brains acquired with a transmission X-ray microscopy. We demonstrate that automated algorithms can reliably trace brain structures in datasets collected with low dose-CNN. As a result, this method can be applied to other tomographic or scanning based X-ray imaging techniques and has great potential for studying faster dynamics in specimens.« less
Low-dose x-ray tomography through a deep convolutional neural network
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Xiaogang; De Andrade, Vincent; Scullin, William
Synchrotron-based X-ray tomography offers the potential of rapid large-scale reconstructions of the interiors of materials and biological tissue at fine resolution. However, for radiation sensitive samples, there remain fundamental trade-offs between damaging samples during longer acquisition times and reducing signals with shorter acquisition times. We present a deep convolutional neural network (CNN) method that increases the acquired X-ray tomographic signal by at least a factor of 10 during low-dose fast acquisition by improving the quality of recorded projections. Short exposure time projections enhanced with CNN show similar signal to noise ratios as compared with long exposure time projections and muchmore » lower noise and more structural information than low-dose fats acquisition without CNN. We optimized this approach using simulated samples and further validated on experimental nano-computed tomography data of radiation sensitive mouse brains acquired with a transmission X-ray microscopy. We demonstrate that automated algorithms can reliably trace brain structures in datasets collected with low dose-CNN. As a result, this method can be applied to other tomographic or scanning based X-ray imaging techniques and has great potential for studying faster dynamics in specimens.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silverman, I.E.; Zeit, R.M.; Von Feldt, J.M.
1994-05-01
Systemic Lupus Erythematosis (SLE) commonly causes significant neuropsychiatric disorders. The purpose of this study was to review the brain SPECT studies of SLE patients with clinical evidence of CNS involvement and determine whether there is a correlation between the findings on SPECT images and the clinical manifestations of this serious phase of the disease. We enrolled 19 SLE patients and 12 normal controls in this study. The level of each patient`s disease activity was determined by the SLE Disease Activity Index (SLEDAI), an established method of scoring disease severity which is heavily weighted toward neuropsychiatric symptomatology, for 15 of themore » 19 SLE patients. The SLEDAI was calculated within a 10 day window of the date when the SPECT scan was obtained. SPECT scans were performed 30 minutes following the intravenous administration of 99mTc-HMPAO. Results are discussed.« less
Hutchinson, P J; Al-Rawi, P G; O'Connell, M T; Gupta, A K; Pickard, J D; Kirkpatrick, P J
2000-01-01
The objective of this study was to monitor brain metabolism on-line during aneurysm surgery, by combining the use of a multiparameter (brain tissue oxygen, brain carbon dioxide, pH, and temperature) sensor with microdialysis (extracellular glucose, lactate, pyruvate, and glutamate). The case illustrates the potential value of these techniques by demonstrating the effects of adverse physiological events on brain metabolism and the ability to assist in both intraoperative and postoperative decision-making. A 41-year-old woman presented with a World Federation of Neurological Surgeons Grade I subarachnoid hemorrhage. Angiography revealed a basilar artery aneurysm that was not amenable to coiling, so the aneurysm was clipped. Before the craniotomy was performed, a multiparameter sensor and a microdialysis catheter were inserted to monitor brain metabolism. During the operation, the brain oxygen level decreased, in relation to biochemical changes, including the reduction of extracellular glucose and pyruvate and the elevation of lactate and glutamate. These changes were reversible. However, when the craniotomy was closed, a second decrease in brain oxygen occurred in association with brain swelling, which immediately prompted a postoperative computed tomographic scan. The scan demonstrated acute hydrocephalus, requiring external ventricular drainage. The patient made a full recovery. The monitoring techniques influenced clinical decision-making in the treatment of this patient. On-line measurement of brain tissue gases and extracellular chemistry has the potential to assist in the perioperative and postoperative management of patients undergoing complex cerebrovascular surgery and to establish the effects of intervention on brain homeostasis.
Changing paradigms in the management of 2184 patients with traumatic brain injury.
Joseph, Bellal; Haider, Ansab A; Pandit, Viraj; Tang, Andrew; Kulvatunyou, Narong; OʼKeeffe, Terence; Rhee, Peter
2015-09-01
The aim of this study was to assess the change in trends in the management of traumatic brain injury (TBI) at a level I trauma center and the utilization of resources as a result of this change in management. The management of TBI has been evolving with trends toward management of minimally injured patients with intracranial hemorrhage exclusively by trauma surgeons. A 5-year (2009-2014) prospective database on all patients with TBI (skull fracture/intracranial hemorrhage on head computed tomography) presenting to a level I trauma center was analyzed for patient demographics, injuries, admission physiology, computed tomographic scan results, and hospital outcomes. These records were matched to the institutional registry and hospital financial database. A total of 2184 patients were included with median (interquartile range) Glasgow Coma Scale score of 15 (12-15), and median (interquartile range) head-abbreviated injury scale score of 3 (2-4). The distribution of types and size of intracranial bleeds remained unchanged throughout the study period. The proportion of TBI managed exclusively by trauma surgeons increased significantly over the years from 6.8% to 40.1% (P < 0.001). Proportion of patients who received neurosurgical consultations (P < 0.001) and repeat head computed tomographic scans (P < 0.001), hospital length of stay (P = 0.028), and costs (P < 0.001) decreased significantly over time. The overall mortality rate (18.5%) and rate of intervention (14.1%) remained unchanged. TBI patients can be selectively managed without initially involving neurosurgeons safely in a cost-effective manner, resulting in more effective use of precious resources.
Glenn, W V; Johnston, R J; Morton, P E; Dwyer, S J
1975-01-01
The various limitations to computerized axial tomographic (CT) interpretation are due in part to the 8-13 mm standard tissue plane thickness and in part to the absence of alternative planes of view, such as coronal or sagittal images. This paper describes a method for gathering multiple overlapped 8 mm transverse sections, subjecting these data to a deconvolution process, and then displaying thin (1 mm) transverse as well as reconstructed coronal and sagittal CT images. Verification of the deconvolution technique with phantom experiments is described. Application of the phantom results to human post mortem CT scan data illustrates this method's faithful reconstruction of coronal and sagittal tissue densities when correlated with actual specimen photographs of a sectioned brain. A special CT procedure, limited basal overlap scanning, is proposed for use on current first generation CT scanners without hardware modification.
Computed tomographic findings of cerebral fat embolism following multiple bone fractures.
Law, Huong Ling; Wong, Siong Lung; Tan, Suzet
2013-02-01
Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.
Single-shot ultrafast tomographic imaging by spectral multiplexing
NASA Astrophysics Data System (ADS)
Matlis, N. H.; Axley, A.; Leemans, W. P.
2012-10-01
Computed tomography has profoundly impacted science, medicine and technology by using projection measurements scanned over multiple angles to permit cross-sectional imaging of an object. The application of computed tomography to moving or dynamically varying objects, however, has been limited by the temporal resolution of the technique, which is set by the time required to complete the scan. For objects that vary on ultrafast timescales, traditional scanning methods are not an option. Here we present a non-scanning method capable of resolving structure on femtosecond timescales by using spectral multiplexing of a single laser beam to perform tomographic imaging over a continuous range of angles simultaneously. We use this technique to demonstrate the first single-shot ultrafast computed tomography reconstructions and obtain previously inaccessible structure and position information for laser-induced plasma filaments. This development enables real-time tomographic imaging for ultrafast science, and offers a potential solution to the challenging problem of imaging through scattering surfaces.
Effect of emergency department CT on neuroimaging case volume and positive scan rates.
Oguz, Kader Karli; Yousem, David M; Deluca, Tom; Herskovits, Edward H; Beauchamp, Norman J
2002-09-01
The authors performed this study to determine the effect a computed tomographic (CT) scanner in the emergency department (ED) has on neuroimaging case volume and positive scan rates. The total numbers of ED visits and neuroradiology CT scans requested from the ED were recorded for 1998 and 2000, the years before and after the installation of a CT unit in the ED. For each examination type (brain, face, cervical spine), studies were graded for major findings (those that affected patient care), minor findings, and normal findings. The CT utilization rates and positive study rates were compared for each type of study performed for both years. There was a statistically significant increase in the utilization rate after installation of the CT unit (P < .001). The fractions of studies with major findings, minor findings, and normal findings changed significantly after installation of the CT unit for facial examinations (P = .002) but not for brain (P = .12) or cervical spine (P = .24) examinations. In all types of studies, the percentage of normal examinations increased. In toto, there was a significant decrease in the positive scan rate after installation of the CT scanner (P = .004). After installation of a CT scanner in the ED, there was increased utilization and a decreased rate of positive neuroradiologic examinations, the latter primarily due to lower positive rates for facial CT scans.
Synthetic Incoherence via Scanned Gaussian Beams
Levine, Zachary H.
2006-01-01
Tomography, in most formulations, requires an incoherent signal. For a conventional transmission electron microscope, the coherence of the beam often results in diffraction effects that limit the ability to perform a 3D reconstruction from a tilt series with conventional tomographic reconstruction algorithms. In this paper, an analytic solution is given to a scanned Gaussian beam, which reduces the beam coherence to be effectively incoherent for medium-size (of order 100 voxels thick) tomographic applications. The scanned Gaussian beam leads to more incoherence than hollow-cone illumination. PMID:27274945
Alterations in L-Glutamate Binding in Alzheimer's and Huntington's Diseases
NASA Astrophysics Data System (ADS)
Greenamyre, J. Timothy; Penney, John B.; Young, Anne B.; D'Amato, Constance J.; Hicks, Samuel P.; Shoulson, Ira
1985-03-01
Brain sections from patients who had died with senile dementia of the Alzheimer's type (SDAT), Huntington's disease (HD), or no neurologic disease were studied by autoradiography to measure sodium-independent L-[3H]glutamate binding. In brain sections from SDAT patients, glutamate binding was normal in the caudate, putamen, and claustrum but was lower than normal in the cortex. The decreased cortical binding represented a reduction in numbers of binding sites, not a change in binding affinity, and appeared to be the result of a specific decrease in numbers of the low-affinity quisqualate binding site. No significant changes in cortical binding of other ligands were observed. In brains from Huntington's disease patients, glutamate binding was lower in the caudate and putamen than in the same regions of brains from control and SDAT patients but was normal in the cortex. It is possible that development of positron-emitting probes for glutamate receptors may permit diagnosis of SDAT in vivo by means of positron emission tomographic scanning.
The evolution of modern human brain shape
Neubauer, Simon; Hublin, Jean-Jacques; Gunz, Philipp
2018-01-01
Modern humans have large and globular brains that distinguish them from their extinct Homo relatives. The characteristic globularity develops during a prenatal and early postnatal period of rapid brain growth critical for neural wiring and cognitive development. However, it remains unknown when and how brain globularity evolved and how it relates to evolutionary brain size increase. On the basis of computed tomographic scans and geometric morphometric analyses, we analyzed endocranial casts of Homo sapiens fossils (N = 20) from different time periods. Our data show that, 300,000 years ago, brain size in early H. sapiens already fell within the range of present-day humans. Brain shape, however, evolved gradually within the H. sapiens lineage, reaching present-day human variation between about 100,000 and 35,000 years ago. This process started only after other key features of craniofacial morphology appeared modern and paralleled the emergence of behavioral modernity as seen from the archeological record. Our findings are consistent with important genetic changes affecting early brain development within the H. sapiens lineage since the origin of the species and before the transition to the Later Stone Age and the Upper Paleolithic that mark full behavioral modernity. PMID:29376123
The evolution of modern human brain shape.
Neubauer, Simon; Hublin, Jean-Jacques; Gunz, Philipp
2018-01-01
Modern humans have large and globular brains that distinguish them from their extinct Homo relatives. The characteristic globularity develops during a prenatal and early postnatal period of rapid brain growth critical for neural wiring and cognitive development. However, it remains unknown when and how brain globularity evolved and how it relates to evolutionary brain size increase. On the basis of computed tomographic scans and geometric morphometric analyses, we analyzed endocranial casts of Homo sapiens fossils ( N = 20) from different time periods. Our data show that, 300,000 years ago, brain size in early H. sapiens already fell within the range of present-day humans. Brain shape, however, evolved gradually within the H. sapiens lineage, reaching present-day human variation between about 100,000 and 35,000 years ago. This process started only after other key features of craniofacial morphology appeared modern and paralleled the emergence of behavioral modernity as seen from the archeological record. Our findings are consistent with important genetic changes affecting early brain development within the H. sapiens lineage since the origin of the species and before the transition to the Later Stone Age and the Upper Paleolithic that mark full behavioral modernity.
Washko, George R; Criner, Gerald J; Mohsenifar, Zab; Sciurba, Frank C; Sharafkhaneh, Amir; Make, Barry J; Hoffman, Eric A; Reilly, John J
2008-06-01
Computed tomographic based indices of emphysematous lung destruction may highlight differences in disease pathogenesis and further enable the classification of subjects with Chronic Obstructive Pulmonary Disease. While there are multiple techniques that can be utilized for such radiographic analysis, there is very little published information comparing the performance of these methods in a clinical case series. Our objective was to examine several quantitative and semi-quantitative methods for the assessment of the burden of emphysema apparent on computed tomographic scans and compare their ability to predict lung mechanics and function. Automated densitometric analysis was performed on 1094 computed tomographic scans collected upon enrollment into the National Emphysema Treatment Trial. Trained radiologists performed an additional visual grading of emphysema on high resolution CT scans. Full pulmonary function test results were available for correlation, with a subset of subjects having additional measurements of lung static recoil. There was a wide range of emphysematous lung destruction apparent on the CT scans and univariate correlations to measures of lung function were of modest strength. No single method of CT scan analysis clearly outperformed the rest of the group. Quantification of the burden of emphysematous lung destruction apparent on CT scan is a weak predictor of lung function and mechanics in severe COPD with no uniformly superior method found to perform this analysis. The CT based quantification of emphysema may augment pulmonary function testing in the characterization of COPD by providing complementary phenotypic information.
Association Between Traumatic Brain Injury-Related Brain Lesions and Long-term Caregiver Burden.
Guevara, Andrea Brioschi; Demonet, Jean-Francois; Polejaeva, Elena; Knutson, Kristine M; Wassermann, Eric M; Grafman, Jordan; Krueger, Frank
2016-01-01
To investigate the association between traumatic brain injury (TBI)-related brain lesions and long-term caregiver burden in relation to dysexecutive syndrome. National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland. A total of 256 participants: 105 combat veterans with TBI, 23 healthy control combat veterans (HCv), and 128 caregivers. Caregiver burden assessed by the Zarit Burden Interview at 40 years postinjury. Participants with penetrating TBI were compared with HCv on perceived caregiver burden and neuropsychological assessment measures. Data of computed tomographic scans (overlay lesion maps of participants with a penetrating TBI whose caregivers have a significantly high burden) and behavioral statistical analyses were combined to identify brain lesions associated with caregiver burden. Burden was greater in caregivers of veterans with TBI than in caregivers of HCv. Caregivers of participants with lesions affecting cognitive and behavioral indicators of dysexecutive syndrome (ie, left dorsolateral prefrontal cortex and dorsal anterior cingulate cortex) showed greater long-term burden than caregivers of participants with lesions elsewhere in the brain. The TBI-related brain lesions have a lasting effect on long-term caregiver burden due to cognitive and behavioral factors associated with dysexecutive syndrome.
Semi-Tomographic Gamma Scanning Technique for Non-Destructive Assay of Radioactive Waste Drums
NASA Astrophysics Data System (ADS)
Gu, Weiguo; Rao, Kaiyuan; Wang, Dezhong; Xiong, Jiemei
2016-12-01
Segmented gamma scanning (SGS) and tomographic gamma scanning (TGS) are two traditional detection techniques for low and intermediate level radioactive waste drum. This paper proposes one detection method named semi-tomographic gamma scanning (STGS) to avoid the poor detection accuracy of SGS and shorten detection time of TGS. This method and its algorithm synthesize the principles of SGS and TGS. In this method, each segment is divided into annual voxels and tomography is used in the radiation reconstruction. The accuracy of STGS is verified by experiments and simulations simultaneously for the 208 liter standard waste drums which contains three types of nuclides. The cases of point source or multi-point sources, uniform or nonuniform materials are employed for comparison. The results show that STGS exhibits a large improvement in the detection performance, and the reconstruction error and statistical bias are reduced by one quarter to one third or less for most cases if compared with SGS.
Malizia, A L; Gunn, R N; Wilson, S J; Waters, S H; Bloomfield, P M; Cunningham, V J; Nutt, D J
1996-01-01
To date, the study of the relationship between drug occupancy and action in the brain has had to rely on the use of either animal models or of indirect kinetic measures in man, e.g. serum concentrations of unbound drug (as a measure of "free" drug in brain). We describe the first set of experiments which directly measure agonist-induced changes in both pharmacodynamic effects and pharmacokinetic parameters simultaneously and which demonstrate the feasibility of these studies in man. Five healthy volunteers each had two PET scans using [11C]flumazenil (a radiolabelled benzodiazepine site antagonist) as part of a study investigating kinetic models and the relationship between occupancy and effect of benzodiazepine site ligands. In both studies the [11C]flumazenil was displaced from the brain by infusion of midazolam administered i.v. 30 min into the scan. In one study a higher dose of midazolam was administered than in the other (range 12.5-50 micrograms/kg). Time-activity curves of the concentration of radioligand were derived in 17 different brain regions using a stereotactic automatic method of region selection. We demonstrated that there are significant differences in an index of occupancy, induced by the two different doses of midazolam, both across brain regions and within subjects. There was a significant correlation between measured occupancy index change and pharmacodynamic effects as measured by the peak change in beta 1 spectral power on EEG. There was no significant correlation between dose administered and EEG changes; plasma concentrations of midazolam were correlated with the occupancy index and with the EEG measures. In addition, we have demonstrated that a non-regional total index of brain occupancy can be obtained by analysing the non-tomographic data obtained with the PET scanner (total radioactivity counts head curve) and that this index shows significant correlations both with the dose administered and with the pharmacodynamic measure. This last finding validates the use of other non-tomographic counting techniques (Malizia et al., 1995a) where an index of displacement can be obtained after the administration of less than 1% of the dose of radiation needed for a PET study. These studies are likely to be useful in human psychopharmacology, in particular in the assessment of tolerance and of putative changes in benzodiazepine sensitivity in anxiety disorders. The same principles can be applied to other ligand studies and will be useful to validate current PK/PD models.
Image processing pipeline for synchrotron-radiation-based tomographic microscopy.
Hintermüller, C; Marone, F; Isenegger, A; Stampanoni, M
2010-07-01
With synchrotron-radiation-based tomographic microscopy, three-dimensional structures down to the micrometer level can be visualized. Tomographic data sets typically consist of 1000 to 1500 projections of 1024 x 1024 to 2048 x 2048 pixels and are acquired in 5-15 min. A processing pipeline has been developed to handle this large amount of data efficiently and to reconstruct the tomographic volume within a few minutes after the end of a scan. Just a few seconds after the raw data have been acquired, a selection of reconstructed slices is accessible through a web interface for preview and to fine tune the reconstruction parameters. The same interface allows initiation and control of the reconstruction process on the computer cluster. By integrating all programs and tools, required for tomographic reconstruction into the pipeline, the necessary user interaction is reduced to a minimum. The modularity of the pipeline allows functionality for new scan protocols to be added, such as an extended field of view, or new physical signals such as phase-contrast or dark-field imaging etc.
Stein, Sherman C; Fabbri, Andrea; Servadei, Franco; Glick, Henry A
2009-02-01
A number of clinical decision aids have been introduced to limit unnecessary computed tomographic scans in patients with mild traumatic brain injury. These aids differ in the risk factors they use to recommend a scan. We compare the instruments according to their sensitivity and specificity and recommend ones based on incremental benefit of correctly classifying patients as having surgical, nonsurgical, or no intracranial lesions. We performed a secondary analysis of prospectively collected database from 7,955 patients aged 10 years or older with mild traumatic brain injury to compare sensitivity and specificity of 6 common clinical decision strategies: the Canadian CT Head Rule, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies, the New Orleans, the National Emergency X-Radiography Utilization Study II (NEXUS-II), the National Institute of Clinical Excellence guideline, and the Scandinavian Neurotrauma Committee guideline. Excluded from the database were patients for whom the history of trauma was unclear, the initial Glasgow Coma Scale score was less than 14, the injury was penetrating, vital signs were unstable, or who refused diagnostic tests. Patients revisiting the emergency department within 7 days were counted only once. The percentage of scans that would have been required by applying each of the 6 aids were Canadian CT head rule (high risk only) 53%, Canadian (medium & high risk) 56%, the Neurotraumatology Committee of the World Federation of Neurosurgical Societies 56%, New Orleans 69%, NEXUS-II 56%, National Institute of Clinical Excellence 71%, and the Scandinavian 50%. The 6 decision aids' sensitivities for surgical hematomas could not be distinguished statistically (P>.05). Sensitivity was 100% (95% confidence interval [CI] 96% to 100%) for NEXUS-II, 98.1% (95% CI 93% to 100%) for National Institute of Clinical Excellence, and 99.1% (95% CI 94% to 100%) for the other 4 clinical decision instruments. Sensitivity for any intracranial lesion ranged from 95.7% (95% CI 93% to 97%) (Scandinavian) to 100% (95% CI 98% to 100%) (National Institute of Clinical Excellence). In contrast, specificities varied between 30.9% (95% CI 30% to 32%) (National Institute of Clinical Excellence) and 52.9% (95% CI 52% to 54) (Scandinavian). NEXUS-II and the Scandinavian clinical decision aids displayed the best combination of sensitivity and specificity in this patient population. However, we cannot demonstrate that the higher sensitivity of NEXUS-II for surgical hematomas is statistically significant. Therefore, choosing which of the 2 clinical decision instruments to use must be based on decisionmakers' attitudes toward risk.
Methods for the correction of vascular artifacts in PET O-15 water brain-mapping studies
NASA Astrophysics Data System (ADS)
Chen, Kewei; Reiman, E. M.; Lawson, M.; Yun, Lang-sheng; Bandy, D.; Palant, A.
1996-12-01
While positron emission tomographic (PET) measurements of regional cerebral blood flow (rCBF) can be used to map brain regions that are involved in normal and pathological human behaviors, measurements in the anteromedial temporal lobe can be confounded by the combined effects of radiotracer activity in neighboring arteries and partial-volume averaging. The authors now describe two simple methods to address this vascular artifact. One method utilizes the early frames of a dynamic PET study, while the other method utilizes a coregistered magnetic resonance image (MRI) to characterize the vascular region of interest (VROI). Both methods subsequently assign a common value to each pixel in the VROI for the control (baseline) scan and the activation scan. To study the vascular artifact and to demonstrate the ability of the proposed methods correcting the vascular artifact, four dynamic PET scans were performed in a single subject during the same behavioral state. For each of the four scans, a vascular scan containing vascular activity was computed as the summation of the images acquired 0-60 s after radiotracer administration, and a control scan containing minimal vascular activity was computed as the summation of the images acquired 20-80 s after radiotracer administration. t-score maps calculated from the four pairs of vascular and control scans were used to characterize regional blood flow differences related to vascular activity before and after the application of each vascular artifact correction method. Both methods eliminated the observed differences in vascular activity, as well as the vascular artifact observed in the anteromedial temporal lobes. Using PET data from a study of normal human emotion, these methods permitted the authors to identify rCBF increases in the anteromedial temporal lobe free from the potentially confounding, combined effects of vascular activity and partial-volume averaging.
Ketoff, Serge; Khonsari, Roman Hossein; Schouman, Thomas; Bertolus, Chloé
2014-11-01
Handling 3-dimensional reconstructions of computed tomographic scans on portable devices is problematic because of the size of the Digital Imaging and Communications in Medicine (DICOM) stacks. The authors provide a user-friendly method allowing the production, transfer, and sharing of good-quality 3-dimensional reconstructions on smartphones and tablets. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Seegobin, Karan; Abdool, Kamille; Ramcharan, Kanterpersad; Dyaanand, Haramnauth; Rampersad, Fidel
2016-09-30
We describe a case of Parry Romberg syndrome/ en coupe de sabre in a woman whose disease started as seizures at age 8 but was diagnosed at the age 39. During these 31 years she got married, completed a first degree at university, had two successful pregnancies and has been gainfully employed. The features of generalized tonic-clonic seizures, autoimmune abnormalities, ocular abnormalities, morphea en coup de sabre and brain imaging abnormalities were present. Areas of parietal lobe cerebral calcification were encountered on the computed tomographic scan and bilateral periventricular white matter changes on the magnetic resonance imaging with frontal, temporal and parietal lobe brain atrophy ipsilateral to the facial hemiatrophy. Clinical, immunologic and neuroradiological abnormalities are discussed. In some cases, this illness can run a benign and stable course.
Acute hydrocephalus caused by intraspinal neurocysticercosis: case report
2014-01-01
Background Intraspinal neurocysticercosis is an uncommon manifestation that may present as an isolated lesion. Furthermore, acute hydrocephalus caused by isolated intraspinal neurocysticercosis without concomitant cerebral involvement is extremely rare. Case presentation A 64-year-old man presented with a history of severe headache, an unsteady gait, and occasional urinary incontinence. Magnetic resonance imaging of the thoraco-lumbar spine revealed multiple, cystic, contrast-enhancing intraspinal lesions. A computed tomographic scan of the brain showed marked ventricular dilatation but no intraparenchymal lesions or intraventricular cysticercal lesions. This case of acute hydrocephalus was found to be caused by isolated intraspinal neurocysticercosis and was treated by ventriculoperitoneal shunt placement and surgical removal of the intraspinal lesions (which were histologically confirmed as neurocysticercosis), followed by administration of dexamethasone and albendazole. Conclusion Isolated spinal neurocysticercosis should be considered in the differential diagnosis of acute hydrocephalus when no explanation is found in the brain, particularly in geographical regions endemic for cysticercosis. PMID:24383427
A new apparatus for electron tomography in the scanning electron microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morandi, V., E-mail: morandi@bo.imm.cnr.it; Maccagnani, P.; Masini, L.
2015-06-23
The three-dimensional reconstruction of a microscopic specimen has been obtained by applying the tomographic algorithm to a set of images acquired in a Scanning Electron Microscope. This result was achieved starting from a series of projections obtained by stepwise rotating the sample under the beam raster. The Scanning Electron Microscope was operated in the scanning-transmission imaging mode, where the intensity of the transmitted electron beam is a monotonic function of the local mass-density and thickness of the specimen. The detection strategy has been implemented and tailored in order to maintain the projection requirement over the large tilt range, as requiredmore » by the tomographic workflow. A Si-based electron detector and an eucentric-rotation specimen holder have been specifically developed for the purpose.« less
Deep Learning MR Imaging-based Attenuation Correction for PET/MR Imaging.
Liu, Fang; Jang, Hyungseok; Kijowski, Richard; Bradshaw, Tyler; McMillan, Alan B
2018-02-01
Purpose To develop and evaluate the feasibility of deep learning approaches for magnetic resonance (MR) imaging-based attenuation correction (AC) (termed deep MRAC) in brain positron emission tomography (PET)/MR imaging. Materials and Methods A PET/MR imaging AC pipeline was built by using a deep learning approach to generate pseudo computed tomographic (CT) scans from MR images. A deep convolutional auto-encoder network was trained to identify air, bone, and soft tissue in volumetric head MR images coregistered to CT data for training. A set of 30 retrospective three-dimensional T1-weighted head images was used to train the model, which was then evaluated in 10 patients by comparing the generated pseudo CT scan to an acquired CT scan. A prospective study was carried out for utilizing simultaneous PET/MR imaging for five subjects by using the proposed approach. Analysis of covariance and paired-sample t tests were used for statistical analysis to compare PET reconstruction error with deep MRAC and two existing MR imaging-based AC approaches with CT-based AC. Results Deep MRAC provides an accurate pseudo CT scan with a mean Dice coefficient of 0.971 ± 0.005 for air, 0.936 ± 0.011 for soft tissue, and 0.803 ± 0.021 for bone. Furthermore, deep MRAC provides good PET results, with average errors of less than 1% in most brain regions. Significantly lower PET reconstruction errors were realized with deep MRAC (-0.7% ± 1.1) compared with Dixon-based soft-tissue and air segmentation (-5.8% ± 3.1) and anatomic CT-based template registration (-4.8% ± 2.2). Conclusion The authors developed an automated approach that allows generation of discrete-valued pseudo CT scans (soft tissue, bone, and air) from a single high-spatial-resolution diagnostic-quality three-dimensional MR image and evaluated it in brain PET/MR imaging. This deep learning approach for MR imaging-based AC provided reduced PET reconstruction error relative to a CT-based standard within the brain compared with current MR imaging-based AC approaches. © RSNA, 2017 Online supplemental material is available for this article.
S-values calculated from a tomographic head/brain model for brain imaging
NASA Astrophysics Data System (ADS)
Chao, Tsi-chian; Xu, X. George
2004-11-01
A tomographic head/brain model was developed from the Visible Human images and used to calculate S-values for brain imaging procedures. This model contains 15 segmented sub-regions including caudate nucleus, cerebellum, cerebral cortex, cerebral white matter, corpus callosum, eyes, lateral ventricles, lenses, lentiform nucleus, optic chiasma, optic nerve, pons and middle cerebellar peduncle, skull CSF, thalamus and thyroid. S-values for C-11, O-15, F-18, Tc-99m and I-123 have been calculated using this model and a Monte Carlo code, EGS4. Comparison of the calculated S-values with those calculated from the MIRD (1999) stylized head/brain model shows significant differences. In many cases, the stylized head/brain model resulted in smaller S-values (as much as 88%), suggesting that the doses to a specific patient similar to the Visible Man could have been underestimated using the existing clinical dosimetry.
Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome.
Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz
2010-01-01
The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. This article throws light on the most serious osseous manifestations of spondylocostal dysostosissyndrome.
Analysis of computer images in the presence of metals
NASA Astrophysics Data System (ADS)
Buzmakov, Alexey; Ingacheva, Anastasia; Prun, Victor; Nikolaev, Dmitry; Chukalina, Marina; Ferrero, Claudio; Asadchikov, Victor
2018-04-01
Artifacts caused by intensely absorbing inclusions are encountered in computed tomography via polychromatic scanning and may obscure or simulate pathologies in medical applications. To improve the quality of reconstruction if high-Z inclusions in presence, previously we proposed and tested with synthetic data an iterative technique with soft penalty mimicking linear inequalities on the photon-starved rays. This note reports a test at the tomographic laboratory set-up at the Institute of Crystallography FSRC "Crystallography and Photonics" RAS in which tomographic scans were successfully made of temporary tooth without inclusion and with Pb inclusion.
Nirula, Ram; Millar, D; Greene, Tom; McFadden, Molly; Shah, Lubdha; Scalea, Thomas M; Stein, Deborah M; Magnotti, Louis J; Jurkovich, Gregory J; Vercruysse, Gary; Demetriades, Demetrios; Scherer, Lynette A; Peitzman, Andrew; Sperry, Jason; Beauchamp, Kathryn; Bell, Scott; Feiz-Erfan, Iman; O'Neill, Patrick; Coimbra, Raul
2014-04-01
Moderate/severe traumatic brain injury (TBI) management involves minimizing cerebral edema to maintain brain oxygen delivery. While medical therapy (MT) consisting of diuresis, hyperosmolar therapy, ventriculostomy, and barbiturate coma is the standard of care, decompressive craniectomy (DC) for refractory intracranial hypertension (ICH) has gained renewed interest. Since TBI treatment guidelines consider DC a second-tier intervention after MT failure, we sought to determine if early DC (<48 hours) was associated with improved survival in patients with refractory ICH. Eleven Level 1 trauma centers provided clinical data and head computed tomographic scans for patients with a Glasgow Coma Scale (GCS) score of 13 or less and radiographic evidence of TBI excluding deaths within 48 hours. Computed tomographic scans were graded according to the Marshall classification. A propensity score to receive DC (regardless of whether DC was performed) was calculated for each patient based on patient characteristics, physiology, injury severity, GCS, severity of intracranial injury, and treatment center. Patients who actually received a DC were matched to patients with similar propensity scores who received MT for analysis. Outcomes were compared between early (<48 hours of injury) primary or secondary DC and matched controls and then between early primary DC only and matched controls. There were 2,602 patients who met the inclusion criteria ,of whom 264 (10.1%) received DC (either primary or secondary to another cranial procedure) and 109 (5%) had a DC that was primary. Variables associated with performing a DC included sex, race, intracranial pressure monitor placement, in-house trauma attending, traumatic subarachnoid hemorrhage, midline shift, and basal cistern compression. There was no survival benefit with early primary DC compared with the controls (relative risk, 1.07; 95% confidence interval, 0.67-1.73; p = 0.77), and resource use was higher. Early DC does not seem to significantly improve mortality in patients with refractory ICH compared with MT. Neurosurgeons should pause before entertaining this resource-demanding form of therapy. Therapeutic care/management, level III.
Mathematical modeling of tomographic scanning of cylindrically shaped test objects
NASA Astrophysics Data System (ADS)
Kapranov, B. I.; Vavilova, G. V.; Volchkova, A. V.; Kuznetsova, I. S.
2018-05-01
The paper formulates mathematical relationships that describe the length of the radiation absorption band in the test object for the first generation tomographic scan scheme. A cylindrically shaped test object containing an arbitrary number of standard circular irregularities is used to perform mathematical modeling. The obtained mathematical relationships are corrected with respect to chemical composition and density of the test object material. The equations are derived to calculate the resulting attenuation radiation from cobalt-60 isotope when passing through the test object. An algorithm to calculate the radiation flux intensity is provided. The presented graphs describe the dependence of the change in the γ-quantum flux intensity on the change in the radiation source position and the scanning angle of the test object.
Vizzeri, Gianmarco; Bowd, Christopher; Medeiros, Felipe A; Weinreb, Robert N; Zangwill, Linda M
2008-08-01
Misalignment of the Stratus optical coherence tomograph scan circle placed by the operator around the optic nerve head (ONH) during each retinal nerve fiber layer (RNFL) examination can affect the instrument reproducibility and its theoretical ability to detect true structural changes in the RNFL thickness over time. We evaluated the effect of scan circle placement on RNFL measurements. Observational clinical study. Sixteen eyes of 8 normal participants were examined using the Stratus optical coherence tomograph Fast RNFL thickness acquisition protocol (software version 4.0.7; Carl Zeiss Meditec, Dublin, CA). Four consecutive images were taken by the same operator with the circular scan centered on the optic nerve head. Four images each with the scan displaced superiorly, inferiorly, temporally, and nasally were also acquired. Differences in average and sectoral RNFL thicknesses were determined. For the centered scans, the coefficients of variation (CV) and the intraclass correlation coefficient for the average RNFL thickness measured were calculated. When the average RNFL thickness of the centered scans was compared with the average RNFL thickness of the displaced scans individually using analysis of variance with post-hoc analysis, no difference was found between the average RNFL thickness of the nasally (105.2 microm), superiorly (106.2 microm), or inferiorly (104.1 microm) displaced scans and the centered scans (106.4 microm). However, a significant difference (analysis of variance with Dunnett's test: F=8.82, P<0.0001) was found between temporally displaced scans (115.8 microm) and centered scans. Significant differences in sectoral RNFL thickness measurements were found between centered and each displaced scan. The coefficient of variation for average RNFL thickness was 1.75% and intraclass correlation coefficient was 0.95. In normal eyes, average RNFL thickness measurements are robust and similar with significant superior, inferior, and nasal scan displacement, but average RNFL thickness is greater when scans are displaced temporally. Parapapillary scan misalignment produces significant changes in RNFL assessment characterized by an increase in measured RNFL thickness in the quadrant in which the scan is closer to the disc, and a significant decrease in RNFL thickness in the quadrant in which the scan is displaced further from the optic disc.
Tomographic assessment of the spine in children with spondylocostal dysotosis syndrome
Kaissi, Ali Al; Klaushofer, Klaus; Grill, Franz
2010-01-01
OBJECTIVE: The aim of this study was to perform a detailed tomographic analysis of the skull base, craniocervical junction, and the entire spine in seven patients with spondylocostal dysostosis syndrome. METHOD: Detailed scanning images have been organized in accordance with the most prominent clinical pathology. The reasons behind plagiocephaly, torticollis, short immobile neck, scoliosis and rigid back have been detected. Radiographic documentation was insufficient modality. RESULTS: Detailed computed tomography scans provided excellent delineation of the osseous abnormality pattern in our patients. CONCLUSION: This article throws light on the most serious osseous manifestations of spondylocostal dysostosis syndrome. PMID:21120293
Lynch, Rod; Pitson, Graham; Ball, David; Claude, Line; Sarrut, David
2013-01-01
To develop a reproducible definition for each mediastinal lymph node station based on the new TNM classification for lung cancer. This paper proposes an atlas using the new international lymph node map used in the seventh edition of the TNM classification for lung cancer. Four radiation oncologists and 1 diagnostic radiologist were involved in the project to put forward a reproducible radiologic description for the lung lymph node stations. The International Association for the Study of Lung Cancer lymph node definitions for stations 1 to 11 have been described and illustrated on axial computed tomographic scan images using a certified radiotherapy planning system. This atlas will assist both diagnostic radiologists and radiation oncologists in accurately defining the lymph node stations on computed tomographic scan in patients diagnosed with lung cancer. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Dudak, J.; Zemlicka, J.; Krejci, F.; Karch, J.; Patzelt, M.; Zach, P.; Sykora, V.; Mrzilkova, J.
2016-03-01
X-ray microradiography and microtomography are imaging techniques with increasing applicability in the field of biomedical and preclinical research. Application of hybrid pixel detector Timepix enables to obtain very high contrast of low attenuating materials such as soft biological tissue. However X-ray imaging of ex-vivo soft tissue samples is a difficult task due to its structural instability. Ex-vivo biological tissue is prone to fast drying-out which is connected with undesired changes of sample size and shape producing later on artefacts within the tomographic reconstruction. In this work we present the optimization of our Timepix equipped micro-CT system aiming to maintain soft tissue sample in stable condition. Thanks to the suggested approach higher contrast of tomographic reconstructions can be achieved while also large samples that require detector scanning can be easily measured.
NASA Astrophysics Data System (ADS)
Bourillot, Eric; Vitry, Pauline; Optasanu, Virgil; Plassard, Cédric; Lacroute, Yvon; Montessin, Tony; Lesniewska, Eric
A general challenge in metallic components is the need for materials research to improve the service lifetime of the structural tanks or tubes subjected to harsh environments or the storage medium for the products. One major problem is the formation of lightest chemical elements bubbles or different chemical association, which can have a significant impact on the mechanical properties and structural stability of materials. The high migration mobility of these light chemical elements in solids presents a challenge for experimental characterization. Here, we present work relating to an original non-destructive, with high spatial resolution, tomographic technique based on Scanning Microwave Microscopy (SMM), which is used to visualize in-depth chemical composition of solid solution of a light chemical element in a metal. The experiments showed the capacity of SMM to detect volume. Measurements realized at different frequencies give access to a tomographic study of the sample.
The neurologic evaluation of patients with low-tension glaucoma.
Corbett, J J; Phelps, C D; Eslinger, P; Montague, P R
1985-08-01
One hypothesized cause of low-tension glaucoma is chronic or intermittent ischemia of the optic nerve. Since the optic nerve and brain are both parts of the central nervous system and share a common blood supply, the authors wondered if patients with low-tension glaucoma might also have clinical or radiographic evidence of cerebral atrophy. In this study, 27 patients with low-tension glaucoma were examined using neurobehavioral testing, electroencephalography, computerized tomographic scan, neurological history, and physical examination. In only a small number of patients were these tests abnormal. However, 12 of the 27 patients gave a history of common or classic migraine. This unexpected finding raises the possibility that migraine-related ischemia might be the pathogenic mechanism in some cases of low-tension glaucoma.
Maxfield, Mark W; Schuster, Kevin M; McGillicuddy, Edward A; Young, Calvin J; Ghita, Monica; Bokhari, S A Jamal; Oliva, Isabel B; Brink, James A; Davis, Kimberly A
2012-12-01
A recent study showed that computed tomographic (CT) scans contributed 93% of radiation exposure of 177 patients admitted to our Level I trauma center. Adaptive statistical iterative reconstruction (ASIR) is an algorithm that reduces the noise level in reconstructed images and therefore allows the use of less ionizing radiation during CT scans without significantly affecting image quality. ASIR was instituted on all CT scans performed on trauma patients in June 2009. Our objective was to determine if implementation of ASIR reduced radiation dose without compromising patient outcomes. We identified 300 patients activating the trauma system before and after the implementation of ASIR imaging. After applying inclusion criteria, 245 charts were reviewed. Baseline demographics, presenting characteristics, number of delayed diagnoses, and missed injuries were recorded. The postexamination volume CT dose index (CTDIvol) and dose-length product (DLP) reported by the scanner for CT scans of the chest, abdomen, and pelvis and CT scans of the brain and cervical spine were recorded. Subjective image quality was compared between the two groups. For CT scans of the chest, abdomen, and pelvis, the mean CTDIvol (17.1 mGy vs. 14.2 mGy; p < 0.001) and DLP (1,165 mGy·cm vs. 1,004 mGy·cm; p < 0.001) was lower for studies performed with ASIR. For CT scans of the brain and cervical spine, the mean CTDIvol (61.7 mGy vs. 49.6 mGy; p < 0.001) and DLP (1,327 mGy·cm vs. 1,067 mGy·cm; p < 0.001) was lower for studies performed with ASIR. There was no subjective difference in image quality between ASIR and non-ASIR scans. All CT scans were deemed of good or excellent image quality. There were no delayed diagnoses or missed injuries related to CT scanning identified in either group. Implementation of ASIR imaging for CT scans performed on trauma patients led to a nearly 20% reduction in ionizing radiation without compromising outcomes or image quality. Therapeutic study, level IV.
Maxfield, Mark W.; Schuster, Kevin M.; McGillicuddy, Edward A.; Young, Calvin J.; Ghita, Monica; Bokhari, S.A. Jamal; Oliva, Isabel B.; Brink, James A.; Davis, Kimberly A.
2013-01-01
BACKGROUND A recent study showed that computed tomographic (CT) scans contributed 93% of radiation exposure of 177 patients admitted to our Level I trauma center. Adaptive statistical iterative reconstruction (ASIR) is an algorithm that reduces the noise level in reconstructed images and therefore allows the use of less ionizing radiation during CT scans without significantly affecting image quality. ASIR was instituted on all CT scans performed on trauma patients in June 2009. Our objective was to determine if implementation of ASIR reduced radiation dose without compromising patient outcomes. METHODS We identified 300 patients activating the trauma system before and after the implementation of ASIR imaging. After applying inclusion criteria, 245 charts were reviewed. Baseline demographics, presenting characteristics, number of delayed diagnoses, and missed injuries were recorded. The postexamination volume CT dose index (CTDIvol) and dose-length product (DLP)reported by the scanner for CT scans of the chest, abdomen, and pelvis and CT scans of the brain and cervical spine were recorded. Subjective image quality was compared between the two groups. RESULTS For CT scans of the chest, abdomen, and pelvis, the mean CTDIvol(17.1 mGy vs. 14.2 mGy; p < 0.001) and DLP (1,165 mGy·cm vs. 1,004 mGy·cm; p < 0.001) was lower for studies performed with ASIR. For CT scans of the brain and cervical spine, the mean CTDIvol(61.7 mGy vs. 49.6 mGy; p < 0.001) and DLP (1,327 mGy·cm vs. 1,067 mGy·cm; p < 0.001) was lower for studies performed with ASIR. There was no subjective difference in image quality between ASIR and non-ASIR scans. All CT scans were deemed of good or excellent image quality. There were no delayed diagnoses or missed injuries related to CT scanning identified in either group. CONCLUSION Implementation of ASIR imaging for CT scans performed on trauma patients led to a nearly 20% reduction in ionizing radiation without compromising outcomes or image quality. PMID:23147183
Accuracy of Computed Tomographic Perfusion in Diagnosis of Brain Death: A Prospective Cohort Study.
Sawicki, Marcin; Sołek-Pastuszka, Joanna; Chamier-Ciemińska, Katarzyna; Walecka, Anna; Bohatyrewicz, Romuald
2018-05-04
BACKGROUND This study was designed to determine diagnostic accuracy of computed tomographic perfusion (CTP) compared to computed tomographic angiography (CTA) for the diagnosis of brain death (BD). MATERIAL AND METHODS Whole-brain CTP was performed in patients diagnosed with BD and in patients with devastating brain injury with preserved brainstem reflexes. CTA was derived from CTP datasets. Cerebral blood flow (CBF) and volume (CBV) were calculated in all brain regions. CTP findings were interpreted as confirming diagnosis of BD (positive) when CBF and CBV in all ROIs were below 10 mL/100 g/min and 1.0 mL/100 g, respectively. CTA findings were interpreted using a 4-point system. RESULTS Fifty brain-dead patients and 5 controls were included. In brain-dead patients, CTP results revealed CBF 0.00-9.98 mL/100 g/min and CBV 0.00-0.99 mL/100 g, and were thus interpreted as positive in all patients. CTA results suggested 7 negative cases, providing 86% sensitivity. In the non-brain-dead group, CTP results revealed CBF 2.37-37.59 mL/100 g/min and CBV 0.73-2.34 mL/100 g. The difference between values of CBF and CBV in the brain-dead and non-brain-dead groups was statistically significant (p=0.002 for CBF and p=0.001 for CBV). CTP findings in all non-brain-dead patients were interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTP in the diagnosis of BD. In all non-brain-dead patients, CTA revealed preserved intracranial filling and was interpreted as negative. This resulted in a specificity of 100% (95% CI, 0.31-1.00) for CTA in diagnosis of BD. CONCLUSIONS Whole-brain CTP seems to be a highly sensitive and specific method in diagnosis of BD.
Ultrafast CT scanning of an oak log for internal defects
Francis G. Wagner; Fred W. Taylor; Douglas S. Ladd; Charles W. McMillin; Fredrick L. Roder
1989-01-01
Detecting internal defects in sawlogs and veneer logs with computerized tomographic (CT) scanning is possible, but has been impractical due to the long scanning time required. This research investigated a new scanner able to acquire 34 cross-sectional log scans per second. This scanning rate translates to a linear log feed rate of 85 feet (25.91 m) per minute at one...
Effect of whole brain radiation on local cerebral glucose utilization in the rat.
d'Avella, D; Cicciarello, R; Albiero, F; Mesiti, M; Gagliardi, M E; Russi, E; d'Aquino, A; Princi, P; d'Aquino, S
1991-04-01
We assessed, by means of the [14C]-2-deoxy-D-glucose autoradiography method, the effect of whole-brain x-radiation on local cerebral glucose utilization in the rat brain. Animals were exposed to conventional fractionation (200 +/- 4 cGy/day, 5 days/week; total dose, 4000 cGy). Metabolic experiments were made 2 to 3 weeks after completion of the radiation exposure. In comparison with control and sham-irradiated animals, cerebral metabolic activity was diffusely decreased after irradiation. Statistically significant decreases in metabolic activity were observed in 13 of 27 brain regions studied. In general, the brain areas with the highest basal metabolic rates showed the greatest percentage of decrease in glucose utilization. The concept that radiation suppresses glucose utilization before any morphological change takes place in the cell structures was the basis of this study. Metabolic alterations after irradiation may explain the syndrome of early delayed deterioration observed in humans after whole-brain radiotherapy. These studies have applications to observations made with the [18F]-fluorodeoxyglucose method in conjunction with positron emission tomographic scans in patients receiving radiation therapy for intracranial malignancies. The data reported here also have potential clinical implications for the evaluation of a risk/benefit ratio for radiotherapy in patients with benign neurosurgical diseases or children undergoing prophylactic treatment of the central nervous system.
Effects of lithium on brain glucose metabolism in healthy men.
Kohno, Tomoya; Shiga, Tohru; Toyomaki, Atsuhito; Kusumi, Ichiro; Matsuyama, Tetsuaki; Inoue, Tetsuya; Katoh, Chietsugu; Koyama, Tsukasa; Tamaki, Nagara
2007-12-01
Lithium is clinically available for the treatment of mood disorders. However, it has remained unclear how lithium acts on the brain to produce its effects. The aim of this study was to evaluate the effects of chronic lithium on human brain activity using positron emission tomography and clarify the correlation between brain activity changes and cognitive functional changes as induced by chronic lithium administration. A total of 20 healthy male subjects (mean age, 32 +/- 6 years) underwent positron emission tomographic scans with F-fluorodeoxyglucose and a battery of neuropsychological tests at baseline condition and after 4 weeks of lithium administration. Brain metabolic data were analyzed using statistical parametric mapping. Lithium increased relative regional cerebral glucose metabolism (rCMRglc) in the bilateral dorsomedial frontal cortices including the anterior cingulate gyrus and decreased rCMRglc in the right cerebellum and left lingual gyrus/cuneus. There was no difference in any of the variables of cognitive functions between the baseline condition and after chronic lithium administration. There was no correlation between rCMRglc changes in any of the brain regions and individual variable changes in any of the neuropsychological tests. The results suggest that the effects of chronic lithium are associated with increased activity in the bilateral dorsomedial frontal cortices including the anterior cingulate gyrus and decreased activity in the right cerebellum and left lingual gyrus/cuneus.
Yin, Ningbei; Wu, Jiajun; Chen, Bo; Song, Tao; Ma, Hengyuan; Zhao, Zhenmin; Wang, Yongqian; Li, Haidong; Wu, Di
2015-03-01
Plastic surgeons have attempted various ways to rebuild the aesthetic subunits of the upper lip in patients with cleft lip with less than perfect results in most cases. We propose that repairing the 3 muscle tension line groups in the nasolabial complex will have improved aesthetic results. Micro-computed tomographic scans were performed on the nasolabial tissues of 5 normal aborted fetuses and used to construct a 3-dimensional model to study the nasolabial muscle complex structure. The micro-computed tomographic (CT) scans showed the close relationship and interaction between the muscle fibers of nasalis, pars peripheralis, levator labii superioris, and pars marginalis. Based on the 2-dimensional images obtained from the micro-computed tomographic scans, we suggest the concept of nasolabial muscle complex and muscle tension line group theory: there is a close relationship among the alar part of the nasalis, depressor septi muscle, orbicularis oris muscle, and levator labii superioris alaeque nasi. The tension line groups are 3 tension line structures in the nasolabial muscle complex that interlock with each other at the intersections and maintain the specific shape and aesthetics of the lip and nose.
Hypothermia is associated with poor outcome in pediatric trauma patients.
Sundberg, Jennifer; Estrada, Cristina; Jenkins, Cathy; Ray, Jacqueline; Abramo, Thomas
2011-11-01
The objective of the study was to determine if hypothermia in pediatric trauma patients is associated with increased mortality. We reviewed the charts of level 1 trauma patients aged 3 months to 17 years who presented between September 2006 and March 2008. We analyzed data for patients with temperatures recorded within 30 minutes of arrival to the pediatric emergency department. Logistic regression models were used to test for associations of hypothermia with death while adjusting for mode of transport, season of year, and presence of intracranial pathology as documented by an abnormal head computed tomographic scan. Of the 226 level 1 trauma patients presenting during the study period, 190 met inclusion criteria. Twenty-one patients (11%) died. The odds ratio (OR) of a hypothermic patient dying was 9.2 times that of a normothermic patient when adjusting for seasonal variation (95% confidence interval [CI], 3.2-26.2; P < 0.0001). The OR of a hypothermic patient dying was 8.7 times that of a normothermic patient when adjusting for mode of transport (ground vs air) (95% CI, 3.1-24.6; P < 0.0001). Although it did not reach statistical significance, there was a trend toward an association between hypothermia and the presence of traumatic brain injury as evidenced by an abnormal head computed tomographic scan (OR = 2.4; 95% CI, 0.9-6.0; P = .07). Hypothermia is a risk factor for increased mortality in pediatric trauma patients. This pilot study warrants a more detailed, multicenter analysis to assess the impact of hypothermia in the pediatric trauma patient. Copyright © 2011 Elsevier Inc. All rights reserved.
McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S
1994-09-01
We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.
Lamb wave tomographic imaging system for aircraft structural health assessment
NASA Astrophysics Data System (ADS)
Schwarz, Willi G.; Read, Michael E.; Kremer, Matthew J.; Hinders, Mark K.; Smith, Barry T.
1999-01-01
A tomographic imaging system using ultrasonic Lamb waves for the nondestructive inspection of aircraft components such as wings and fuselage is being developed. The computer-based system provides large-area inspection capability by electronically scanning an array of transducers that can be easily attached to flat and curved surface without moving parts. Images of the inspected area are produced in near real time employing a tomographic reconstruction method adapted from seismological applications. Changes in material properties caused by structural flaws such as disbonds, corrosion, and fatigue cracks can be effectively detected and characterized utilizing this fast NDE technique.
Automated brain computed tomographic densitometry of early ischemic changes in acute stroke
Stoel, Berend C.; Marquering, Henk A.; Staring, Marius; Beenen, Ludo F.; Slump, Cornelis H.; Roos, Yvo B.; Majoie, Charles B.
2015-01-01
Abstract. The Alberta Stroke Program Early CT score (ASPECTS) scoring method is frequently used for quantifying early ischemic changes (EICs) in patients with acute ischemic stroke in clinical studies. Varying interobserver agreement has been reported, however, with limited agreement. Therefore, our goal was to develop and evaluate an automated brain densitometric method. It divides CT scans of the brain into ASPECTS regions using atlas-based segmentation. EICs are quantified by comparing the brain density between contralateral sides. This method was optimized and validated using CT data from 10 and 63 patients, respectively. The automated method was validated against manual ASPECTS, stroke severity at baseline and clinical outcome after 7 to 10 days (NIH Stroke Scale, NIHSS) and 3 months (modified Rankin Scale). Manual and automated ASPECTS showed similar and statistically significant correlations with baseline NIHSS (R=−0.399 and −0.277, respectively) and with follow-up mRS (R=−0.256 and −0.272), except for the follow-up NIHSS. Agreement between automated and consensus ASPECTS reading was similar to the interobserver agreement of manual ASPECTS (differences <1 point in 73% of cases). The automated ASPECTS method could, therefore, be used as a supplementary tool to assist manual scoring. PMID:26158082
In vivo multiphoton tomography and fluorescence lifetime imaging of human brain tumor tissue.
Kantelhardt, Sven R; Kalasauskas, Darius; König, Karsten; Kim, Ella; Weinigel, Martin; Uchugonova, Aisada; Giese, Alf
2016-05-01
High resolution multiphoton tomography and fluorescence lifetime imaging differentiates glioma from adjacent brain in native tissue samples ex vivo. Presently, multiphoton tomography is applied in clinical dermatology and experimentally. We here present the first application of multiphoton and fluorescence lifetime imaging for in vivo imaging on humans during a neurosurgical procedure. We used a MPTflex™ Multiphoton Laser Tomograph (JenLab, Germany). We examined cultured glioma cells in an orthotopic mouse tumor model and native human tissue samples. Finally the multiphoton tomograph was applied to provide optical biopsies during resection of a clinical case of glioblastoma. All tissues imaged by multiphoton tomography were sampled and processed for conventional histopathology. The multiphoton tomograph allowed fluorescence intensity- and fluorescence lifetime imaging with submicron spatial resolution and 200 picosecond temporal resolution. Morphological fluorescence intensity imaging and fluorescence lifetime imaging of tumor-bearing mouse brains and native human tissue samples clearly differentiated tumor and adjacent brain tissue. Intraoperative imaging was found to be technically feasible. Intraoperative image quality was comparable to ex vivo examinations. To our knowledge we here present the first intraoperative application of high resolution multiphoton tomography and fluorescence lifetime imaging of human brain tumors in situ. It allowed in vivo identification and determination of cell density of tumor tissue on a cellular and subcellular level within seconds. The technology shows the potential of rapid intraoperative identification of native glioma tissue without need for tissue processing or staining.
Locating knots by industrial tomography- A feasibility study
Fred W. Taylor; Francis G. Wagner; Charles W. McMillin; Ira L. Morgan; Forrest F. Hopkins
1984-01-01
Industrial photon tomography was used to scan four southern pine logs and one red oak log. The logs were scanned at 16 cross-sectional slice planes located 1 centimeter apart along their longitudinal axes. Tomographic reconstructions were made from the scan data collected at these slice planes, and a cursory image analysis technique was developed to locate the log...
A scanning PIV method for fine-scale turbulence measurements
NASA Astrophysics Data System (ADS)
Lawson, John M.; Dawson, James R.
2014-12-01
A hybrid technique is presented that combines scanning PIV with tomographic reconstruction to make spatially and temporally resolved measurements of the fine-scale motions in turbulent flows. The technique uses one or two high-speed cameras to record particle images as a laser sheet is rapidly traversed across a measurement volume. This is combined with a fast method for tomographic reconstruction of the particle field for use in conjunction with PIV cross-correlation. The method was tested numerically using DNS data and with experiments in a large mixing tank that produces axisymmetric homogeneous turbulence at . A parametric investigation identifies the important parameters for a scanning PIV set-up and provides guidance to the interested experimentalist in achieving the best accuracy. Optimal sheet spacings and thicknesses are reported, and it was found that accurate results could be obtained at quite low scanning speeds. The two-camera method is the most robust to noise, permitting accurate measurements of the velocity gradients and direct determination of the dissipation rate.
Normal-pressure hydrocephalus and the saga of the treatable dementias
DOE Office of Scientific and Technical Information (OSTI.GOV)
Friedland, R.P.
1989-11-10
A case study of a 74-year-old woman is presented which illustrates the difficulty of understanding dementing illnesses. A diagnosis of normal-pressure hydrocephalus (NPH) was made because of the development of abnormal gait, with urinary incontinence and severe, diffuse, white matter lesions on the MRI scan. Computed tomographic, MRI scans and positron emission tomographic images of glucose use are presented. The treatable dementias are a large, multifaceted group of illnesses, of which NPH is one. The author proposes a new term for this disorder commonly known as NPH because the problem with the term normal-pressure hydrocephalus is that the cerebrospinal fluidmore » pressure is not always normal in the disease.« less
Yudkowsky, Rachel; Luciano, Cristian; Banerjee, Pat; Schwartz, Alan; Alaraj, Ali; Lemole, G Michael; Charbel, Fady; Smith, Kelly; Rizzi, Silvio; Byrne, Richard; Bendok, Bernard; Frim, David
2013-02-01
Ventriculostomy is a neurosurgical procedure for providing therapeutic cerebrospinal fluid drainage. Complications may arise during repeated attempts at placing the catheter in the ventricle. We studied the impact of simulation-based practice with a library of virtual brains on neurosurgery residents' performance in simulated and live surgical ventriculostomies. Using computed tomographic scans of actual patients, we developed a library of 15 virtual brains for the ImmersiveTouch system, a head- and hand-tracked augmented reality and haptic simulator. The virtual brains represent a range of anatomies including normal, shifted, and compressed ventricles. Neurosurgery residents participated in individual simulator practice on the library of brains including visualizing the 3-dimensional location of the catheter within the brain immediately after each insertion. Performance of participants on novel brains in the simulator and during actual surgery before and after intervention was analyzed using generalized linear mixed models. Simulator cannulation success rates increased after intervention, and live procedure outcomes showed improvement in the rate of successful cannulation on the first pass. However, the incidence of deeper, contralateral (simulator) and third-ventricle (live) placements increased after intervention. Residents reported that simulations were realistic and helpful in improving procedural skills such as aiming the probe, sensing the pressure change when entering the ventricle, and estimating how far the catheter should be advanced within the ventricle. Simulator practice with a library of virtual brains representing a range of anatomies and difficulty levels may improve performance, potentially decreasing complications due to inexpert technique.
New Severity Indices for Quantifying Single-suture Metopic Craniosynostosis
Ruiz-Correa, Salvador; Starr, Jacqueline R.; Lin, H. Jill; Kapp-Simon, Kathleen A.; Sze, Raymond W.; Ellenbogen, Richard G.; Speltz, Matthew L.; Cunningham, Michael L.
2012-01-01
OBJECTIVE To describe novel severity indices with which to quantify severity of trigonocephaly malformation in children diagnosed with isolated metopic synostosis. METHODS Computed tomographic scans of the cranium were obtained from 38 infants diagnosed with isolated metopic synostosis and 53 age-matched control patients. Volumetric reformations of the cranium were used to trace two-dimensional planes defined by the cranium-base plane and well-defined brain landmarks. For each patient, novel trigonocephaly severity indices (TSI) were computed from outline cranium shapes on each of these planes. The metopic severity index based on measurements of interlandmark distances was also computed and a receiver operating characteristic analysis used to compare the accuracy of classification based on TSIs versus that based on the metopic severity index. RESULTS The proposed TSIs are a sensitive measure of trigonocephaly malformation that can provide a classification accuracy of 96% with a specificity of 95%, in contrast with 82% of the metopic severity index at the same specificity level. CONCLUSIONS We completed exploratory analysis of outline-based severity measurements computed from computed tomographic image planes of the cranium. These TSIs enable quantitative analysis of cranium features in isolated metopic synostosis that may not be accurately detected by analytic tools derived from a sparse set of traditional interlandmark and semilandmark distances. PMID:18797362
Schmidt, Sergio L; Schmidt, Juliana J; Tolentino, Julio C; Ferreira, Carlos G; de Almeida, Sergio A; Alvarenga, Regina P; Simoes, Eunice N; Schmidt, Guilherme J; Canedo, Nathalie H S; Chimelli, Leila
2016-07-20
Limbic encephalitis was originally described as a rare clinical neuropathological entity involving seizures and neuropsychological disturbances. In this report, we describe cerebral patterns visualized by positron emission tomography in a patient with limbic encephalitis and cholangiocarcinoma. To our knowledge, there is no other description in the literature of cerebral positron emission tomography findings in the setting of limbic encephalitis and subsequent diagnosis of cholangiocarcinoma. We describe a case of a 77-year-old Caucasian man who exhibited persistent cognitive changes 2 years before his death. A cerebral scan obtained at that time by 2-deoxy-2-[fluorine-18]fluoro- D -glucose integrated with computed tomography-positron emission tomography showed low radiotracer uptake in the frontal and temporal lobes. Cerebrospinal fluid analysis indicated the presence of voltage-gated potassium channel antibodies. Three months before the patient's death, a lymph node biopsy indicated a cholangiocarcinoma, and a new cerebral scan obtained by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography showed an increment in the severity of metabolic deficit in the frontal and parietal lobes, as well as hypometabolism involving the temporal lobes. Two months before the patient's death, cerebral metastases were detected on a contrast-enhanced computed tomographic scan. Postmortem examination revealed a cholangiocarcinoma with multiple metastases including the lungs and lymph nodes. The patient's brain weighed 1300 g, and mild cortical atrophy, ex vacuo dilation of the ventricles, and mild focal thickening of the cerebellar leptomeninges, which were infiltrated by neoplastic epithelial cells, were observed. These findings support the need for continued vigilance in malignancy surveillance in patients with limbic encephalitis and early cerebral positron emission tomographic scan abnormalities. The difficulty in early diagnosis of small tumors, such as a cholangiocarcinoma, is discussed in the context of the clinical utility of early cerebral hypometabolism detected by 2-deoxy-2-[fluorine-18]fluoro-D-glucose integrated with computed tomography-positron emission tomography in patients with rapidly progressive dementia.
Intravenous volume tomographic pulmonary angiography imaging
NASA Astrophysics Data System (ADS)
Ning, Ruola; Strang, John G.; Chen, Biao; Conover, David L.; Yu, Rongfeng
1999-05-01
This study presents a new intravenous (IV) tomographic angiography imaging technique, called intravenous volume tomographic digital angiography (VTDA) for cross sectional pulmonary angiography. While the advantages of IV-VTDA over spiral CT in terms of volume scanning time and resolution have been validated and reported in our previous papers for head and neck vascular imaging, the superiority of IV-VTDA over spiral CT for cross sectional pulmonary angiography has not been explored yet. The purpose of this study is to demonstrate the advantage of isotropic resolution of IV-VTDA in the x, y and z directions through phantom and animal studies, and to explore its clinical application for detecting clots in pulmonary angiography. A prototype image intensifier-based VTDA imaging system has been designed and constructed by modifying a GE 8800 CT scanner. This system was used for a series of phantom and dog studies. A pulmonary vascular phantom was designed and constructed. The phantom was scanned using the prototype VTDA system for direct 3D reconstruction. Then the same phantom was scanned using a GE CT/i spiral CT scanner using the routine pulmonary CT angiography protocols. IV contrast injection and volume scanning protocols were developed during the dog studies. Both VTDA reconstructed images and spiral CT images of the specially designed phantom were analyzed and compared. The detectability of simulated vessels and clots was assessed as the function of iodine concentration levels, oriented angles, and diameters of the vessels and clots. A set of 3D VTDA reconstruction images of dog pulmonary arteries was obtained with different IV injection rates and isotropic resolution in the x, y and z directions. The results of clot detection studies in dog pulmonary arteries have also been shown. This study presents a new tomographic IV angiography imaging technique for cross sectional pulmonary angiography. The results of phantom and animal studies indicate that IV-VTDA is superior to spiral CT for cross sectional pulmonary angiography.
Medical ultrasonic tomographic system
NASA Technical Reports Server (NTRS)
Heyser, R. C.; Lecroissette, D. H.; Nathan, R.; Wilson, R. L.
1977-01-01
An electro-mechanical scanning assembly was designed and fabricated for the purpose of generating an ultrasound tomogram. A low cost modality was demonstrated in which analog instrumentation methods formed a tomogram on photographic film. Successful tomogram reconstructions were obtained on in vitro test objects by using the attenuation of the fist path ultrasound signal as it passed through the test object. The nearly half century tomographic methods of X-ray analysis were verified as being useful for ultrasound imaging.
Neuroanatomy of flying reptiles and implications for flight, posture and behaviour.
Witmer, Lawrence M; Chatterjee, Sankar; Franzosa, Jonathan; Rowe, Timothy
2003-10-30
Comparison of birds and pterosaurs, the two archosaurian flyers, sheds light on adaptation to an aerial lifestyle. The neurological basis of control holds particular interest in that flight demands on sensory integration, equilibrium, and muscular coordination are acute. Here we compare the brain and vestibular apparatus in two pterosaurs based on high-resolution computed tomographic (CT) scans from which we constructed digital endocasts. Although general neural organization resembles birds, pterosaurs had smaller brains relative to body mass than do birds. This difference probably has more to do with phylogeny than flight, in that birds evolved from nonavian theropods that had already established trends for greater encephalization. Orientation of the osseous labyrinth relative to the long axis of the skull was different in these two pterosaur species, suggesting very different head postures and reflecting differing behaviours. Their enlarged semicircular canals reflect a highly refined organ of equilibrium, which is concordant with pterosaurs being visually based, aerial predators. Their enormous cerebellar floccular lobes may suggest neural integration of extensive sensory information from the wing, further enhancing eye- and neck-based reflex mechanisms for stabilizing gaze.
Uduma, Uduma Felix; Pius, Fokam; Mathieu, Motah
2012-01-01
Objective: Intracranial calcifications underlie certain brain diseases which may be de novo or systemic. But calclfications un-connected to pathologies are classified physiological. Aim: To evaluate physiological intracranial calcifications in Douala with establishment of earliest age range of detection. Materials and Methods: Prospective study of brain computed tomograms was done from April to October 2009 using Schumadzu CT Scan machine. Axial, reconstructed and bone window images as well Hounsfield unit measurements were used for final evaluations. Results were analysed with SSPS 3. Results: 132 patients with 75 males and 57 females were studied and 163 separate calcifications were identified due to co-existent calcifications. The highest calcification was in choroid plexi, constituiting 56.82% of the studied population. This was followed by pineal gland. Both were commonly co-existent with advancing age. These calcifications were first seen at 10-19years. No type of physiological intracranial calcification was seen below age 10. The least calcification of 0.76% of population was in dentate nucleus. Conclusion: No intra-cranial physiological calcifications started earlier than 9years in Douala, a city in Cameroon, Central Africa. PMID:22980109
Uduma, Felix Uduma; Pius, Fokam; Mathieu, Motah
2011-12-29
Intracranial calcifications underlie certain brain diseases which may be de novo or systemic. But calcifications un-connected to pathologies are classified physiological. To evaluate physiological intracranial calcifications in Douala with establishment of earliest age range of detection. Prospective study of brain computed tomograms was done from April to October 2009 using Schumadzu CT Scan machine. Axial, reconstructed and bone window images as well Hounsfield unit measurements were used for final evaluations. RESULTS were analysed with SSPS 3. 132 patients with 75 males and 57 females were studied and 163 separate calcifications were identified due to co-existent calcifications. The highest calcification was in choroid plexi, constituting 56.82% of the studied population. This was followed by pineal gland. Both were commonly co-existent with advancing age. These calcifications were first seen at 10-19 years. No type of physiological intracranial calcification was seen below age 10. The least calcification of 0.76% of population was in dentate nucleus. No intra-cranial physiological calcifications started earlier than 9 years in Douala, a city in Cameroon, Central Africa.
Occult fractures of the knee: tomographic evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apple, J.S.; Martinez, S.; Allen, N.B.
1983-08-01
Seven adults with painful effusions of the knee were examined for occult fractures using pluridirectional tomograph in the coronal and lateral planes. Six patients (ages 50 to 82 years) were osteopenic and gave histories ranging from none to mild trauma; one 26-year-old man was not osteopenic and had severe trauma. In all cases, routine radiographs were interpreted as negative, but tomography demonstrated a fracture. Five fractures were subchondral. Bone scans in 2 patients were positive. The authors conclude that osteopenic patients with a painful effusion of the knee should be considered to have an occult fracture. While bone scans maymore » be helpful, tomography is recommended as the procedure of choice to define the location and extent of the fracture.« less
Hopper, Richard A; Sandercoe, Gavin; Woo, Albert; Watts, Robyn; Kelley, Patrick; Ettinger, Russell E; Saltzman, Babette
2010-11-01
Le Fort III distraction requires generation of bone in the pterygomaxillary region. The authors performed retrospective digital analysis on temporal fine-cut computed tomographic images to quantify both radiographic evidence of pterygomaxillary region bone formation and relative maxillary stability. Fifteen patients with syndromic midface hypoplasia were included in the study. The average age of the patients was 8.7 years; 11 had either Crouzon or Apert syndrome. The average displacement of the maxilla during distraction was 16.2 mm (range, 7 to 31 mm). Digital analysis was performed on fine-cut computed tomographic scans before surgery, at device removal, and at annual follow-up. Seven patients also had mid-consolidation computed tomographic scans. Relative maxillary stability and density of radiographic bone in the pterygomaxillary region were calculated between each scan. There was no evidence of clinically significant maxillary relapse, rotation, or growth between the end of consolidation and 1-year follow-up, other than a relatively small 2-mm subnasal maxillary vertical growth. There was an average radiographic ossification of 0.5 mm/mm advancement at the time of device removal, with a 25th percentile value of 0.3 mm/mm. The time during consolidation that each patient reached the 25th percentile of pterygomaxillary region bone density observed in this series of clinically stable advancements ranged from 1.3 to 9.8 weeks (average, 3.7 weeks). There was high variability in the amount of bone formed in the pterygomaxillary region associated with clinical stability of the advanced Le Fort III segment. These data suggest that a subsection of patients generate the minimal amount of pterygomaxillary region bone formation associated with advancement stability as early as 4 weeks into consolidation.
Antonopoulos, Markos; Stamatakos, Georgios
2015-01-01
Intensive glioma tumor infiltration into the surrounding normal brain tissues is one of the most critical causes of glioma treatment failure. To quantitatively understand and mathematically simulate this phenomenon, several diffusion-based mathematical models have appeared in the literature. The majority of them ignore the anisotropic character of diffusion of glioma cells since availability of pertinent truly exploitable tomographic imaging data is limited. Aiming at enriching the anisotropy-enhanced glioma model weaponry so as to increase the potential of exploiting available tomographic imaging data, we propose a Brownian motion-based mathematical analysis that could serve as the basis for a simulation model estimating the infiltration of glioblastoma cells into the surrounding brain tissue. The analysis is based on clinical observations and exploits diffusion tensor imaging (DTI) data. Numerical simulations and suggestions for further elaboration are provided.
NASA Astrophysics Data System (ADS)
Staton, Robert J.
Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.
Chemical imaging analysis of the brain with X-ray methods
NASA Astrophysics Data System (ADS)
Collingwood, Joanna F.; Adams, Freddy
2017-04-01
Cells employ various metal and metalloid ions to augment the structure and the function of proteins and to assist with vital biological processes. In the brain they mediate biochemical processes, and disrupted metabolism of metals may be a contributing factor in neurodegenerative disorders. In this tutorial review we will discuss the particular role of X-ray methods for elemental imaging analysis of accumulated metal species and metal-containing compounds in biological materials, in the context of post-mortem brain tissue. X-rays have the advantage that they have a short wavelength and can penetrate through a thick biological sample. Many of the X-ray microscopy techniques that provide the greatest sensitivity and specificity for trace metal concentrations in biological materials are emerging at synchrotron X-ray facilities. Here, the extremely high flux available across a wide range of soft and hard X-rays, combined with state-of-the-art focusing techniques and ultra-sensitive detectors, makes it viable to undertake direct imaging of a number of elements in brain tissue. The different methods for synchrotron imaging of metals in brain tissues at regional, cellular, and sub-cellular spatial resolution are discussed. Methods covered include X-ray fluorescence for elemental imaging, X-ray absorption spectrometry for speciation imaging, X-ray diffraction for structural imaging, phase contrast for enhanced contrast imaging and scanning transmission X-ray microscopy for spectromicroscopy. Two- and three-dimensional (confocal and tomographic) imaging methods are considered as well as the correlation of X-ray microscopy with other imaging tools.
Fisher, Brian M; Cowles, Steven; Matulich, Jennifer R; Evanson, Bradley G; Vega, Diana; Dissanaike, Sharmila
2013-12-01
Guidelines are in place directing the clearance of the cervical spine in patients who are awake, alert, and oriented, but a gold standard has not been recognized for patients who are obtunded. Our study is designed to determine if magnetic resonance imaging (MRI) detects clinically significant injuries not seen on computed tomographic (CT) scans. The trauma registry was used to identify and retrospectively review medical records of blunt trauma patients from January 1, 2005, to March 30, 2012. Only obtunded patients with a CT scan and MRI of the cervical spine were included. The study cohort consisted of 277 patients. In 13 (5%) patients, MRI detected clinically significant cervical spine injuries that were missed by CT scans, and in 7 (3%) these injuries required intervention. The number needed to screen with MRI to prevent 1 missed injury was 21. The findings suggest that the routine use of MRI in clearing the cervical spine in the obtunded blunt trauma patient. Copyright © 2013 Elsevier Inc. All rights reserved.
Hernigou, P; Germany, W
1998-09-01
Within an anatomical and a clinical study, the authors employed computerized tomographic scans to evaluate the risks of anterior surrounding tissues injuries during screw insertion. CT scans of 20 patients suffering from cardiac disease were reviewed retrospectively. Scans through the thoracic and lumbar spine were obtained using 6 mm slice thickness. These examinations were performed with intravenous contrast medium. Measurements of vessel diameters and distance of the soft tissues situated directly anterior to the spine were done. A retrospective study of 61 pedicle screws implanted for spine fractures evaluated the penetration of the anterior vertebral cordex with X rays and CT scans. Computerized tomographic scans of the thoracic and lumbar spine of the 20 patients in the control group confirmed proximity of the posterior mediastinal structures to the anterior vertebral cortex. Many structures of the posterior mediastinum were within five millimeters of the anterior vertebral cortex and thus were at risk: aorta, azygos vein, vena cava, parietal pleura and lungs. The theoretical risk of unrecognized screw penetrations evaluated on geometric shape of the anterior vertebral body is as high as 21 per cent when screw position is only seen with an antero posterior and a lateral X Ray. In the other group, computerized tomographic scans showed that 30 per cent of the implanted screws were outside the boundaries of the anterior thoracic spine. Two orthogonal incidences do not enable determination of whether the extremity of the screw is slightly outside the anterior cortex of the vertebral body. However the geometric shape of the anterior vertebral body enables peroperative definition of a safety zone on two orthogonal incidences. Even if a breach of a few millimeters of the anterior cortical boundaries of the vertebral body may not initially damage the adjacent soft-tissue structures, chronic irritation may result in late damages of these structures. The use of metallic markers and the respect of a safe vertebral zone on X Rays could guide the choice of the appropriate screw length.
Jeng, Toh Charng; Haspani, Mohd Saffari Mohd; Adnan, Johari Siregar; Naing, Nyi Nyi
2008-01-01
A repeat Computer Tomographic (CT) brain after 24–48 hours from the 1st scanning is usually practiced in most hospitals in South East Asia where intracranial pressure monitoring (ICP) is routinely not done. This interval for repeat CT would be shortened if there was a deterioration in Glasgow Coma Scale (GCS). Most of the time the prognosis of any intervention may be too late especially in hospitals with high patient-to-doctor ratio causing high mortality and morbidity. The purpose of this study was to determine the important predictors for early detection of Delayed Traumatic Intracranial Haemorrhage (DTICH) and Progressive Traumatic Brain Injury (PTBI) before deterioration of GCS occurred, as well as the most ideal timing of repeated CT brain for patients admitted in Malaysian hospitals. A total of 81 patients were included in this study over a period of six months. The CT scan brain was studied by comparing the first and second CT brain to diagnose the presence of DTICH/PTBI. The predictors tested were categorised into patient factors, CT brain findings and laboratory investigations. The mean age was 33.1 ± 15.7 years with a male preponderance of 6.36:1. Among them, 81.5% were patients from road traffic accidents with Glasgow Coma Scale ranging from 4 – 15 (median of 12) upon admission. The mean time interval delay between trauma and first CT brain was 179.8 ± 121.3 minutes for the PTBI group. The DTICH group, 9.9% of the patients were found to have new intracranial clots. Significant predictors detected were different referral hospitals (p=0.02), total GCS status (p=0.026), motor component of GCS (p=0.043), haemoglobin level (p<0.001), platelet count (p=0.011) and time interval between trauma and first CT brain (p=0.022). In the PTBI group, 42.0% of the patients were found to have new changes (new clot occurrence, old clot expansion and oedema) in the repeat CT brain. Univariate statistical analysis revealed that age (p=0.03), race (p=0.035), types of admission (p=0.024), GCS status (p=0.02), pupillary changes (p=0.014), number of intracranial lesion (p=0.004), haemoglobin level (p=0.038), prothrombin time (p=0.016) as the best predictors of early detection of changes. Multiple logistics regression analysis indicated that age, severity, GCS status (motor component) and GCS during admission were significantly associated with second CT scan with changes. This study showed that 9.9% of the total patients seen in the period of study had DTICH and 42% had PTBI. In the early period after traumatic head injury, the initial CT brain did not reveal the full extent of haemorrhagic injury and associated cerebral oedema. Different referral hospitals of different trauma level, GCS status, motor component of the GCS, haemoglobin level, platelet count and time interval between trauma and the first CT brain were the significant predictors for DTICH. Whereas the key determinants of PTBI were age, race, types of admission, GCS status, pupillary changes, number of intracranial bleed, haemoglobin level, prothrombin time and of course time interval between trauma and first CT brain. Any patients who had traumatic head injury in hospitals with no protocol of repeat CT scan or intracranial pressure monitoring especially in developing countries are advised to have to repeat CT brain at the appropriate quickest time . PMID:22589639
1987-01-01
BLOOD FLOW CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus Raichle McDonnell Center for Studies of Higher Brain Function...Single Words Using Positron Emission Tomographic Measurements of Cerebral Blood Flow Change *= ’I PERSONAL AUTHOR(S) * Petersen, Steven E. 13a. TYPE OF...CHANGE Steven E. Petersen, Peter T. Fox, Michael I. Posner, Marcus E. Raichle INTRODUCTION Language is an essential characteristic of the human
Optical tomographic memories: algorithms for the efficient information readout
NASA Astrophysics Data System (ADS)
Pantelic, Dejan V.
1990-07-01
Tomographic alogithms are modified in order to reconstruct the inf ormation previously stored by focusing laser radiation in a volume of photosensitive media. Apriori information about the position of bits of inf ormation is used. 1. THE PRINCIPLES OF TOMOGRAPHIC MEMORIES Tomographic principles can be used to store and reconstruct the inf ormation artificially stored in a bulk of a photosensitive media 1 The information is stored by changing some characteristics of a memory material (e. g. refractive index). Radiation from the two independent light sources (e. g. lasers) is f ocused inside the memory material. In this way the intensity of the light is above the threshold only in the localized point where the light rays intersect. By scanning the material the information can be stored in binary or nary format. When the information is stored it can be read by tomographic methods. However the situation is quite different from the classical tomographic problem. Here a lot of apriori information is present regarding the p0- sitions of the bits of information profile representing single bit and a mode of operation (binary or n-ary). 2. ALGORITHMS FOR THE READOUT OF THE TOMOGRAPHIC MEMORIES Apriori information enables efficient reconstruction of the memory contents. In this paper a few methods for the information readout together with the simulation results will be presented. Special attention will be given to the noise considerations. Two different
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tait, Paul; Waheed, Umeer; Bell, Suzanne, E-mail: drsuzy29@hotmail.co
2009-07-15
The insertion of a chest drain catheter for the management of a pneumothorax in an 82-year-old woman resulted in the unusual complication of liver penetration. The position of the drain was assessed by contrast-enhanced computed tomographic scan. Because the patient was hemodynamically stable and no damage to major vessels was seen on computed tomographic scan, the patient was treated in a nonoperative manner. A procedure was performed under controlled conditions using techniques used during transhepatic liver biopsies but with the addition of a balloon catheter. Embolization of the liver track was performed during chest drain removal. The drain was successfullymore » removed without the complication of bleeding in a patient unsuitable for a general anesthetic.« less
NASA Astrophysics Data System (ADS)
Yatsishina, E. B.; Kovalchuk, M. V.; Loshak, M. D.; Vasilyev, S. V.; Vasilieva, O. A.; Dyuzheva, O. P.; Pojidaev, V. M.; Ushakov, V. L.
2018-05-01
Nine ancient Egyptian mummies (dated preliminarily to the period from the 1st mill. BCE to the first centuries CE) from the collection of the State Pushkin Museum of Fine Arts have been studied at the National Research Centre "Kurchatov Institute" (NRC KI) on the base of the complex of NBICS technologies. Tomographic scanning is performed using a magneto-resonance tomograph (3 T) and a hybrid positron emission tomography/computed tomography (PET-CT) scanner. Three-dimensional reconstructions of mummies and their anthropological measurements are carried out. Some medical conclusions are drawn based on the tomographic data. In addition, the embalming composition and tissue of one of the mummies are preliminarily analyzed.
Robust statistical reconstruction for charged particle tomography
Schultz, Larry Joe; Klimenko, Alexei Vasilievich; Fraser, Andrew Mcleod; Morris, Christopher; Orum, John Christopher; Borozdin, Konstantin N; Sossong, Michael James; Hengartner, Nicolas W
2013-10-08
Systems and methods for charged particle detection including statistical reconstruction of object volume scattering density profiles from charged particle tomographic data to determine the probability distribution of charged particle scattering using a statistical multiple scattering model and determine a substantially maximum likelihood estimate of object volume scattering density using expectation maximization (ML/EM) algorithm to reconstruct the object volume scattering density. The presence of and/or type of object occupying the volume of interest can be identified from the reconstructed volume scattering density profile. The charged particle tomographic data can be cosmic ray muon tomographic data from a muon tracker for scanning packages, containers, vehicles or cargo. The method can be implemented using a computer program which is executable on a computer.
NASA Astrophysics Data System (ADS)
Giacometti, Paolo; Diamond, Solomon G.
Diffuse optical tomography (DOT) is a functional brain imaging technique that measures cerebral blood oxygenation and blood volume changes. This technique is particularly useful in human neuroimaging measurements because of the coupling between neural and hemodynamic activity in the brain. DOT is a multichannel imaging extension of near-infrared spectroscopy (NIRS). NIRS uses laser sources and light detectors on the scalp to obtain noninvasive hemodynamic measurements from spectroscopic analysis of the remitted light. This review explains how NIRS data analysis is performed using a combination of the modified Beer-Lambert law (MBLL) and the diffusion approximation to the radiative transport equation (RTE). Laser diodes, photodiode detectors, and optical terminals that contact the scalp are the main components in most NIRS systems. Placing multiple sources and detectors over the surface of the scalp allows for tomographic reconstructions that extend the individual measurements of NIRS into DOT. Mathematically arranging the DOT measurements into a linear system of equations that can be inverted provides a way to obtain tomographic reconstructions of hemodynamics in the brain.
Hintz, S R; Cheong, W F; van Houten, J P; Stevenson, D K; Benaron, D A
1999-01-01
Medical optical imaging (MOI) uses light emitted into opaque tissues to determine the interior structure. Previous reports detailed a portable time-of-flight and absorbance system emitting pulses of near infrared light into tissues and measuring the emerging light. Using this system, optical images of phantoms, whole rats, and pathologic neonatal brain specimens have been tomographically reconstructed. We have now modified the existing instrumentation into a clinically relevant headband-based system to be used for optical imaging of structure in the neonatal brain at the bedside. Eight medical optical imaging studies in the neonatal intensive care unit were performed in a blinded clinical comparison of optical images with ultrasound, computed tomography, and magnetic resonance imaging. Optical images were interpreted as correct in six of eight cases, with one error attributed to the age of the clot, and one small clot not seen. In addition, one disagreement with ultrasound, not reported as an error, was found to be the result of a mislabeled ultrasound report rather than because of an inaccurate optical scan. Optical scan correlated well with computed tomography and magnetic resonance imaging findings in one patient. We conclude that light-based imaging using a portable time-of-flight system is feasible and represents an important new noninvasive diagnostic technique, with potential for continuous monitoring of critically ill neonates at risk for intraventricular hemorrhage or stroke. Further studies are now underway to further investigate the functional imaging capabilities of this new diagnostic tool.
NASA Astrophysics Data System (ADS)
Schäfer, D.; Lin, M.; Rao, P. P.; Loffroy, R.; Liapi, E.; Noordhoek, N.; Eshuis, P.; Radaelli, A.; Grass, M.; Geschwind, J.-F. H.
2012-03-01
C-arm based tomographic 3D imaging is applied in an increasing number of minimal invasive procedures. Due to the limited acquisition speed for a complete projection data set required for tomographic reconstruction, breathing motion is a potential source of artifacts. This is the case for patients who cannot comply breathing commands (e.g. due to anesthesia). Intra-scan motion estimation and compensation is required. Here, a scheme for projection based local breathing motion estimation is combined with an anatomy adapted interpolation strategy and subsequent motion compensated filtered back projection. The breathing motion vector is measured as a displacement vector on the projections of a tomographic short scan acquisition using the diaphragm as a landmark. Scaling of the displacement to the acquisition iso-center and anatomy adapted volumetric motion vector field interpolation delivers a 3D motion vector per voxel. Motion compensated filtered back projection incorporates this motion vector field in the image reconstruction process. This approach is applied in animal experiments on a flat panel C-arm system delivering improved image quality (lower artifact levels, improved tumor delineation) in 3D liver tumor imaging.
Neuwelt, E A; Maravilla, K R; Frenkel, E P; Rapaport, S I; Hill, S A; Barnett, P A
1979-01-01
The present study describes a canine model of transient reversible blood-brain barrier disruption with hyperosmolar mannitol infusion into the internal carotid artery. Studies in this model show that osmotic blood-brain barrier disruption before intracarotid infusion of methotrexate results in markedly elevated (therapeutic) levels of drug in the ipsilateral cerebral hemisphere. Levels in the cerebrospinal fluid correlate poorly and inconsistently with brain levels. Computerized tomograms in this canine model provide a noninvasive monitor of the degree, time-course, and localization of osmotic blood-brain barrier disruption. Images PMID:457877
4D x-ray phase contrast tomography for repeatable motion of biological samples
NASA Astrophysics Data System (ADS)
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm3. A maximum volume size of 13 × 13 × 6 mm3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
4D x-ray phase contrast tomography for repeatable motion of biological samples.
Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto
2016-09-01
X-ray phase contrast tomography based on a grating interferometer was applied to fast and dynamic measurements of biological samples. To achieve this, the scanning procedure in the tomographic scan was improved. A triangle-shaped voltage signal from a waveform generator to a Piezo stage was used for the fast phase stepping in the grating interferometer. In addition, an optical fiber coupled x-ray scientific CMOS camera was used to achieve fast and highly efficient image acquisitions. These optimizations made it possible to perform an x-ray phase contrast tomographic measurement within an 8 min scan with density resolution of 2.4 mg/cm 3 . A maximum volume size of 13 × 13 × 6 mm 3 was obtained with a single tomographic measurement with a voxel size of 6.5 μm. The scanning procedure using the triangle wave was applied to four-dimensional measurements in which highly sensitive three-dimensional x-ray imaging and a time-resolved dynamic measurement of biological samples were combined. A fresh tendon in the tail of a rat was measured under a uniaxial stretching and releasing condition. To maintain the freshness of the sample during four-dimensional phase contrast tomography, the temperature of the bathing liquid of the sample was kept below 10° using a simple cooling system. The time-resolved deformation of the tendon and each fascicle was measured with a temporal resolution of 5.7 Hz. Evaluations of cross-sectional area size, length of the axis, and mass density in the fascicle during a stretching process provided a basis for quantitative analysis of the deformation of tendon fascicle.
Interlaced X-ray diffraction computed tomography
Vamvakeros, Antonios; Jacques, Simon D. M.; Di Michiel, Marco; Senecal, Pierre; Middelkoop, Vesna; Cernik, Robert J.; Beale, Andrew M.
2016-01-01
An X-ray diffraction computed tomography data-collection strategy that allows, post experiment, a choice between temporal and spatial resolution is reported. This strategy enables time-resolved studies on comparatively short timescales, or alternatively allows for improved spatial resolution if the system under study, or components within it, appear to be unchanging. The application of the method for studying an Mn–Na–W/SiO2 fixed-bed reactor in situ is demonstrated. Additionally, the opportunities to improve the data-collection strategy further, enabling post-collection tuning between statistical, temporal and spatial resolutions, are discussed. In principle, the interlaced scanning approach can also be applied to other pencil-beam tomographic techniques, like X-ray fluorescence computed tomography, X-ray absorption fine structure computed tomography, pair distribution function computed tomography and tomographic scanning transmission X-ray microscopy. PMID:27047305
X-ray fluorescence tomographic system design and image reconstruction.
Cong, Wenxiang; Shen, Haiou; Cao, Guohua; Liu, Hong; Wang, Ge
2013-01-01
In this paper, we presented a new design of x-ray fluorescence CT imaging system. For detecting fuorescence signals of gold nanoparticles in-vivo, multiple spectroscopic detectors are arranged and rotated orthogonal to an excited region of interest so that a localized scan can be acquired with a maximized efficiency. Excitation filtration was employed to minimize the effects of low-energy x-rays and background scattering for lowering radiation dose to the object. Numerical simulations showed that the radiation dose is less than 300 mGy/second for a complete 30 views tomographic scan; and the sensitivity of 3D fluorescence signal detection is up to 0.2% contrast concentrations of nanoparticles. The x-ray fluorescence computed tomography is an important molecular imaging tool. It can be used directly in samall animal research. It has great translational potential for future clinical applications.
New developments in multimodal clinical multiphoton tomography
NASA Astrophysics Data System (ADS)
König, Karsten
2011-03-01
80 years ago, the PhD student Maria Goeppert predicted in her thesis in Goettingen, Germany, two-photon effects. It took 30 years to prove her theory, and another three decades to realize the first two-photon microscope. With the beginning of this millennium, first clinical multiphoton tomographs started operation in research institutions, hospitals, and in the cosmetic industry. The multiphoton tomograph MPTflexTM with its miniaturized flexible scan head became the Prism-Award 2010 winner in the category Life Sciences. Multiphoton tomographs with its superior submicron spatial resolution can be upgraded to 5D imaging tools by adding spectral time-correlated single photon counting units. Furthermore, multimodal hybrid tomographs provide chemical fingerprinting and fast wide-field imaging. The world's first clinical CARS studies have been performed with a hybrid multimodal multiphoton tomograph in spring 2010. In particular, nonfluorescent lipids and water as well as mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen have been imaged in patients with dermatological disorders. Further multimodal approaches include the combination of multiphoton tomographs with low-resolution imaging tools such as ultrasound, optoacoustic, OCT, and dermoscopy systems. Multiphoton tomographs are currently employed in Australia, Japan, the US, and in several European countries for early diagnosis of skin cancer (malignant melanoma), optimization of treatment strategies (wound healing, dermatitis), and cosmetic research including long-term biosafety tests of ZnO sunscreen nanoparticles and the measurement of the stimulated biosynthesis of collagen by anti-ageing products.
Rose, Michael; Rubal, Bernard; Hulten, Edward; Slim, Jennifer N; Steel, Kevin; Furgerson, James L; Villines, Todd C
2014-01-01
Background: The correlation between normal cardiac chamber linear dimensions measured during retrospective coronary computed tomographic angiography as compared to transthoracic echocardiography using the American Society of Echocardiography guidelines is not well established. Methods: We performed a review from January 2005 to July 2011 to identify subjects with retrospective electrocardiogram-gated coronary computed tomographic angiography scans for chest pain and transthoracic echocardiography with normal cardiac structures performed within 90 days. Dimensions were manually calculated in both imaging modalities in accordance with the American Society of Echocardiography published guidelines. Left ventricular ejection fraction was calculated on echocardiography manually using the Simpson’s formula and by coronary computed tomographic angiography using the end-systolic and end-diastolic volumes. Results: We reviewed 532 studies, rejected 412 and had 120 cases for review with a median time between studies of 7 days (interquartile range (IQR25,75) = 0–22 days) with no correlation between the measurements made by coronary computed tomographic angiography and transthoracic echocardiography using Bland–Altman analysis. We generated coronary computed tomographic angiography cardiac dimension reference ranges for both genders for our population. Conclusion: Our findings represent a step towards generating cardiac chamber dimensions’ reference ranges for coronary computed tomographic angiography as compared to transthoracic echocardiography in patients with normal cardiac morphology and function using the American Society of Echocardiography guideline measurements that are commonly used by cardiologists. PMID:26770706
Laser microbeam CT scanning of dosimetry gels
NASA Astrophysics Data System (ADS)
Maryanski, Marek J.; Ranade, Manisha K.
2001-06-01
A novel design of an optical tomographic scanner is described that can be used for 3D mapping of optical attenuation coefficient within translucent cylindrical objects with spatial resolution on the order of 100 microns. Our scanner design utilizes the cylindrical geometry of the imaged object to obtain the desired paths of the scanning light rays. A rotating mirror and a photodetector are placed at two opposite foci of the translucent cylinder that acts as a cylindrical lens. A He-Ne laser beam passes first through a focusing lens and then is reflected by the rotating mirror, so as to scan the interior of the cylinder with focused and parallel paraxial rays that are subsequently collected by the photodetector to produce the projection data, as the cylinder rotates in small angle increments between projections. Filtered backprojection is then used to reconstruct planar distributions of optical attenuation coefficient in the cylinder. Multiplanar scans are used to obtain a complete 3D tomographic reconstruction. Among other applications, the scanner can be used in radiation therapy dosimetry and quality assurance for mapping 3D radiation dose distributions in various types of tissue-equivalent gel phantoms that change their optical attenuation coefficients in proportion to the absorbed radiation dose.
Zyluk, Andrzej; Mazur, Agnieszka; Piotuch, Bernard
2015-01-01
The objective of the study was an assessment of the occurrence of traumatic cerebral lesions and skull fractures in patients with mild head trauma. A total of 171 patients' notes, 89 male (52%) and 82 female (48%), mean age 48 years, were subjected to analysis. Of the 171 patients, in 58 (34%) CT scanning of the head was not performed for various reasons, and these patients were discharged home. Of the remaining 113 persons, who had head CT performed, in 99 (88%) no abnormalities were found; in 10 (9%) CT scans revealed pathological findings unrelated to the trauma: most frequently cortical-subcortical atrophy followed by old post-stroke foci, and in 4 patients (3%) post-traumatic pathologies: skull fractures in 2 and facial bone fractures in 2. Diagnosis of these fractures did not change the conservative treatment of these patients, but only prolonged in-patient stay for 2-3 days. All skull and facial bone fractures occurred in patients who were alcohol intoxicated, were lying, could not maintain vertical position, or who had the "racoon eyes" sign. The results of our study show that lack of abnormalities in neurological examination in patients after mild head injury is a reliable indicator for omitting CT scanning, because the risk of overlooking brain injuries in these patients is minimal. However, patients who are intoxicated, have problems with maintaining a vertical position and have the "racoon eyes" sign, are likely to have skull or facial fractures, and CT scanning is therefore justified. Considering these precursors (guidelines) and the use of clinical decision rules described in the article may reduce the number of head CT scans performed "just in a case".
CCD-camera-based diffuse optical tomography to study ischemic stroke in preclinical rat models
NASA Astrophysics Data System (ADS)
Lin, Zi-Jing; Niu, Haijing; Liu, Yueming; Su, Jianzhong; Liu, Hanli
2011-02-01
Stroke, due to ischemia or hemorrhage, is the neurological deficit of cerebrovasculature and is the third leading cause of death in the United States. More than 80 percent of stroke patients are ischemic stroke due to blockage of artery in the brain by thrombosis or arterial embolism. Hence, development of an imaging technique to image or monitor the cerebral ischemia and effect of anti-stoke therapy is more than necessary. Near infrared (NIR) optical tomographic technique has a great potential to be utilized as a non-invasive image tool (due to its low cost and portability) to image the embedded abnormal tissue, such as a dysfunctional area caused by ischemia. Moreover, NIR tomographic techniques have been successively demonstrated in the studies of cerebro-vascular hemodynamics and brain injury. As compared to a fiberbased diffuse optical tomographic system, a CCD-camera-based system is more suitable for pre-clinical animal studies due to its simpler setup and lower cost. In this study, we have utilized the CCD-camera-based technique to image the embedded inclusions based on tissue-phantom experimental data. Then, we are able to obtain good reconstructed images by two recently developed algorithms: (1) depth compensation algorithm (DCA) and (2) globally convergent method (GCM). In this study, we will demonstrate the volumetric tomographic reconstructed results taken from tissuephantom; the latter has a great potential to determine and monitor the effect of anti-stroke therapies.
Coe, Ryan L; Seibel, Eric J
2013-09-01
We present theoretical and experimental results of axial displacement of objects relative to a fixed condenser focal plane (FP) in optical projection tomographic microscopy (OPTM). OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The cell rotates in a microcapillary to acquire projections from different perspectives where the objective FP is scanned through the cell while the condenser FP remains fixed at the center of the microcapillary. This work uses a combination of experimental and theoretical methods to improve the OPTM instrument design.
Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...
Yoon, Seo Yeon; Kim, Je-Kyung; An, Young-Sil; Kim, Yong Wook
2015-01-01
Aphasia is one of the most common neurologic deficits occurring after stroke. Although the speech-language therapy is a mainstream option for poststroke aphasia, pharmacotherapy is recently being tried to modulate different neurotransmitter systems. However, the efficacy of those treatments is still controversial. We present a case of a 53-year-old female patient with Wernicke aphasia, after the old infarction in the territory of left middle cerebral artery for 8 years and the recent infarction in the right middle cerebral artery for 4 months. On the initial evaluation, the Aphasia Quotient in Korean version of the Western Aphasia Battery was 25.6 of 100. Baseline brain F-18 fluorodeoxyglucose positron emission tomographic images demonstrated a decreased cerebral metabolism in the left temporoparietal area and right temporal lobe. Donepezil hydrochloride, a reversible acetylcholinesterase inhibitor, was orally administered 5 mg/d for 6 weeks after the initial evaluation and was increased to 10 mg/d for the following 6 weeks. After the donepezil treatment, the patient showed improvement in language function, scoring 51.0 of 100 on Aphasia Quotient. A subtraction analysis of the brain F-18 fluorodeoxyglucose positron emission tomographic images after donepezil medication demonstrated increased uptake in both middle temporal gyri, extended to the occipital area and the left cerebellum. Thus, we suggest that donepezil can be an effective therapeutic choice for the treatment of Wernicke aphasia.
Gandhi, Rohit; Lewis, Evan Cole; Evans, Jeanette W; Sell, Erick
2015-03-01
Headaches are a common problem in the pediatric population. In 2002, the American Academy of Neurology (AAN) developed guidelines on neuroimaging for patients presenting with headache. Our objective was to determine the frequency of computed tomographic (CT) scanning ordered by a range of medical practitioners for pediatric patients presenting with primary headache. A retrospective chart review was conducted at the Children's Hospital of Eastern Ontario (CHEO), a tertiary care centre in Ontario. One hundred fifty-one records of patients referred to the outpatient neurology clinic at CHEO with ''headache'' or ''migraine'' as the primary complaint from 2004 to 2009 were randomly selected. Ninety-nine patients with normal neurologic examinations were ultimately included. Thirty-four patients (34%; 95% CI 25-45) had undergone CT scanning. None of the 34 CT scans (0%; 95% CI 0-10) showed significant findings, and none changed the headache diagnosis or management. Eleven (32%) of the CT scans were ordered by CHEO neurologists, 15 (44%) by community physicians, and 8 (24%) by CHEO emergency physicians. A high proportion of children presenting with primary headaches and a normal neurologic examination undergo CT scanning, despite well-established AAN guidelines regarding neuroimaging. Most of these CT scans do not appear to alter diagnosis and management. A variety of non-evidencebased factors may be encouraging physicians to overinvestigate this population and, as a result, increasing the risk of adverse events due to radiation exposure. Implementing initiatives at a site-based level that promote the use of established guidelines before performing CT scanning in this population may be beneficial.
TOMOGRAPHIC MORPHOLOGICAL STUDY OF THE CRANIUM AND ITS CORRELATION WITH CRANIAL HALO USE IN ADULTS
ALMEIDA, TIAGO FERREIRA DE; CHARAFEDDINE, HOMAR TOLEDO; ARAÚJO, FERNANDO FLORES DE; CRISTANTE, ALEXANDRE FOGAÇA; MARCON, RAPHAEL MARTUS; LETAIF, OLAVO BIRAGHI
2017-01-01
ABSTRACT Objective: To evaluate using tomographic study the thickness of the cranial board at the insertions points of the cranial halo pins in adults Methods: This is a retrospective, cross-sectional, descriptive analysis of Computed Tomography (CT) scans of adult patients' crania. The study included adults between 20 and 50 years without cranial abnormalities. We excluded any exam with cranial abnormalities Results: We analyzed 50 CT scans, including 27 men and 23 women, at the original insertion points and alternative points (1 and 2 cm above the frontal and parietal bones). The average values were 7.4333 mm in the frontal bone and 6.0290 mm in the parietal bone Conclusion: There was no statistically significant difference between the classical and alternative points, making room for alternative fixings and safer introduction of the pins, if necessary.Level of Evidence II, Retrospective Study. PMID:28642643
NASA Technical Reports Server (NTRS)
Mcdade, Ian C.
1991-01-01
Techniques were developed for recovering two-dimensional distributions of auroral volume emission rates from rocket photometer measurements made in a tomographic spin scan mode. These tomographic inversion procedures are based upon an algebraic reconstruction technique (ART) and utilize two different iterative relaxation techniques for solving the problems associated with noise in the observational data. One of the inversion algorithms is based upon a least squares method and the other on a maximum probability approach. The performance of the inversion algorithms, and the limitations of the rocket tomography technique, were critically assessed using various factors such as (1) statistical and non-statistical noise in the observational data, (2) rocket penetration of the auroral form, (3) background sources of emission, (4) smearing due to the photometer field of view, and (5) temporal variations in the auroral form. These tests show that the inversion procedures may be successfully applied to rocket observations made in medium intensity aurora with standard rocket photometer instruments. The inversion procedures have been used to recover two-dimensional distributions of auroral emission rates and ionization rates from an existing set of N2+3914A rocket photometer measurements which were made in a tomographic spin scan mode during the ARIES auroral campaign. The two-dimensional distributions of the 3914A volume emission rates recoverd from the inversion of the rocket data compare very well with the distributions that were inferred from ground-based measurements using triangulation-tomography techniques and the N2 ionization rates derived from the rocket tomography results are in very good agreement with the in situ particle measurements that were made during the flight. Three pre-prints describing the tomographic inversion techniques and the tomographic analysis of the ARIES rocket data are included as appendices.
Combination of CT scanning and fluoroscopy imaging on a flat-panel CT scanner
NASA Astrophysics Data System (ADS)
Grasruck, M.; Gupta, R.; Reichardt, B.; Suess, Ch.; Schmidt, B.; Stierstorfer, K.; Popescu, S.; Brady, T.; Flohr, T.
2006-03-01
We developed and evaluated a prototype flat-panel detector based Volume CT (fpVCT) scanner. The fpVCT scanner consists of a Varian 4030CB a-Si flat-panel detector mounted in a multi slice CT-gantry (Siemens Medical Solutions). It provides a 25 cm field of view with 18 cm z-coverage at the isocenter. In addition to the standard tomographic scanning, fpVCT allows two new scan modes: (1) fluoroscopic imaging from any arbitrary rotation angle, and (2) continuous, time-resolved tomographic scanning of a dynamically changing viewing volume. Fluoroscopic imaging is feasible by modifying the standard CT gantry so that the imaging chain can be oriented along any user-selected rotation angle. Scanning with a stationary gantry, after it has been oriented, is equivalent to a conventional fluoroscopic examination. This scan mode enables combined use of high-resolution tomography and real-time fluoroscopy with a clinically usable field of view in the z direction. The second scan mode allows continuous observation of a timeevolving process such as perfusion. The gantry can be continuously rotated for up to 80 sec, with the rotation time ranging from 3 to 20 sec, to gather projection images of a dynamic process. The projection data, that provides a temporal log of the viewing volume, is then converted into multiple image stacks that capture the temporal evolution of a dynamic process. Studies using phantoms, ex vivo specimens, and live animals have confirmed that these new scanning modes are clinically usable and offer a unique view of the anatomy and physiology that heretofore has not been feasible using static CT scanning. At the current level of image quality and temporal resolution, several clinical applications such a dynamic angiography, tumor enhancement pattern and vascularity studies, organ perfusion, and interventional applications are in reach.
Colorectal cancer screening with virtual colonoscopy
NASA Astrophysics Data System (ADS)
Ge, Yaorong; Vining, David J.; Ahn, David K.; Stelts, David R.
1999-05-01
Early detection and removal of colorectal polyps have been proven to reduce mortality from colorectal carcinoma (CRC), the second leading cause of cancer deaths in the United States. Unfortunately, traditional techniques for CRC examination (i.e., barium enema, sigmoidoscopy, and colonoscopy) are unsuitable for mass screening because of either low accuracy or poor public acceptance, costs, and risks. Virtual colonoscopy (VC) is a minimally invasive alternative that is based on tomographic scanning of the colon. After a patient's bowel is optimally cleansed and distended with gas, a fast tomographic scan, typically helical computed tomography (CT), of the abdomen is performed during a single breath-hold acquisition. Two-dimensional (2D) slices and three-dimensional (3D) rendered views of the colon lumen generated from the tomographic data are then examined for colorectal polyps. Recent clinical studies conducted at several institutions including ours have shown great potential for this technology to be an effective CRC screening tool. In this paper, we describe new methods to improve bowel preparation, colon lumen visualization, colon segmentation, and polyp detection. Our initial results show that VC with the new bowel preparation and imaging protocol is capable of achieving accuracy comparable to conventional colonoscopy and our new algorithms for image analysis contribute to increased accuracy and efficiency in VC examinations.
Bush, Lisa; Brookshire, Robert; Roche, Breanna; Johnson, Amelia; Cole, Frederic; Karmy-Jones, Riyad; Long, William; Martin, Matthew J
2016-09-01
Current trauma guidelines dictate that the cervical spine should not be cleared in intoxicated patients, resulting in prolonged immobilization or additional imaging. Modern computed tomography (CT) technology may obviate this and allow for immediate clearance. To analyze cervical spine clearance practices and the utility of CT scans of the cervical spine in intoxicated patients with blunt trauma. We performed a prospective observational study of 1668 patients with blunt trauma aged 18 years and older who underwent cervical spine CT scans from March 2014 to March 2015 at an American College of Surgeons-verified Level I trauma center. Intoxication was determined by serum alcohol levels and urine drug screens. Physical examination and CT scan findings were evaluated for cervical spine injuries (CSI) and the incidence of missed injuries. Clinically relevant CSIs requiring cervical stabilization. The hypotheses formed prior to data collection were that cervical CT scans are sensitive and specific enough to diagnose CSIs that require stabilization and that normal CT scans are sufficient to clear CSIs in intoxicated patients. Of 1668 patients, 1103 (66.1%) were male, with a mean (SD) age of 49 (20) years and a mean (SD) Injury Severity Score of 10 (9). Vehicular (734 [44.0%]) and falls (579 [34.7%]) were the most common mechanisms for hospitalization. Intoxication was identified in 632 of 1429 of patients tested (44.2%; 425 [29.7%] by serum alcohol levels and 350 [24.5%] by urine drug screens). Half (316 [50.0%]) were admitted with cervical spine immobilization, and 38 (12%) of these were solely owing to the presence of intoxication. There were 65 abnormal CT scans (10.3%) in the intoxicated group. Among 567 normal CT scans, 4 (0.7%) had central cord syndrome found on initial physical examination, and 1 (0.2%) had a symptomatic unstable ligament injury that was misread as normal on CT scan but was abnormal on magnetic resonance imaging. The 316 patients kept in a cervical collar for intoxication had no missed CSIs but were kept immobilized for a mean (SD) of 12 (19) hours. Computed tomographic scans had an overall negative predictive value of 99.2% for patients with CSIs and a negative predictive value of 99.8% for ruling out CSIs that required immobilization or stabilization. In this study, alcohol or drug intoxication was common and resulted in significant delays to cervical spine clearance. Computed tomographic scans were highly reliable for identifying all clinically significant CSIs. Spine clearance based on a normal CT scan among intoxicated patients with no gross motor deficits appears to be safe and avoids prolonged and unnecessary immobilization.
Optoacoustic imaging in five dimensions
NASA Astrophysics Data System (ADS)
Deán-Ben, X. L.; Gottschalk, Sven; Fehm, Thomas F.; Razansky, Daniel
2015-03-01
We report on an optoacoustic imaging system capable of acquiring volumetric multispectral optoacoustic data in real time. The system is based on simultaneous acquisition of optoacoustic signals from 256 different tomographic projections by means of a spherical matrix array. Thereby, volumetric reconstructions can be done at high frame rate, only limited by the pulse repetition rate of the laser. The developed tomographic approach presents important advantages over previously reported systems that use scanning for attaining volumetric optoacoustic data. First, dynamic processes, such as the biodistribution of optical biomarkers, can be monitored in the entire volume of interest. Second, out-of-plane and motion artifacts that could degrade the image quality when imaging living specimens can be avoided. Finally, real-time 3D performance can obviously save time required for experimental and clinical observations. The feasibility of optoacoustic imaging in five dimensions, i.e. real time acquisition of volumetric datasets at multiple wavelengths, is reported. In this way, volumetric images of spectrally resolved chromophores are rendered in real time, thus offering an unparallel imaging performance among the current bio-imaging modalities. This performance is subsequently showcased by video-rate visualization of in vivo hemodynamic changes in mouse brain and handheld visualization of blood oxygenation in deep human vessels. The newly discovered capacities open new prospects for translating the optoacoustic technology into highly performing imaging modality for biomedical research and clinical practice with multiple applications envisioned, from cardiovascular and cancer diagnostics to neuroimaging and ophthalmology.
What is the best imaging strategy for acute stroke?
Wardlaw, J M; Keir, S L; Seymour, J; Lewis, S; Sandercock, P A G; Dennis, M S; Cairns, J
2004-01-01
To determine the cost-effectiveness of computed tomographic (CT) scanning after acute stroke. To assess the contribution of brain imaging to the diagnosis and management of stroke, and to estimate the costs, benefits and risks of different imaging strategies in order to provide data to inform national and local policy on the use of brain imaging in stroke. A decision-analysis model was developed to represent the pathway of care in acute stroke using 'scan all patients within 48 hours' as the comparator against which to cost 12 alternative scan strategies. Hospitals in Scotland. Subjects were patients admitted to hospital with a first stroke and those managed as outpatients. The effect on functional outcome after ischaemic or haemorrhagic stroke, tumours or infections, of correctly administered antithrombotic or other treatment; of time to scan and stroke severity on diagnosis by CT or MRI; on management, including length of stay, functional outcome, and quality-adjusted life years (QALYs), of the diagnostic information provided by CT scanning; the cost-effectiveness (cost versus QALYs) of different strategies for use of CT after acute stroke. Death and functional outcome at long-term follow-up; accuracy of CT and MRI; cost of CT scanning by time of day and week; effect of CT diagnosis on change in health outcome, length of stay in hospital and QALYs; cost-effectiveness of various scanning strategies. CT is very sensitive and specific for haemorrhage within the first 8 days of stroke only. Suboptimal scanning used in epidemiology studies suggests that the frequency of primary intracerebral haemorrhage (PICH) has been underestimated. Aspirin increases the risk of PICH. There were no reliable data on functional outcome or on the effect of antithrombotic treatment given long term after PICH. In 60% of patients with recurrent stroke after PICH, the cause is another PICH and mortality is high among PICH patients. A specific MR sequence (gradient echo) is required to identify prior PICH reliably. CT scanners were distributed unevenly in Scotland, 65% provided CT scanning within 48 hours of stroke, and 100% within 7 days for hospital-admitted patients, but access out of hours was very variable, and for outpatients was poor. The average cost of a CT brain scan for stroke was pounds 30.23 to pounds 89.56 in normal working hours and pounds 55.05 to pounds 173.46 out of hours. Average length of stay was greatest for severe strokes and those who survived in a dependent state. For a cohort of 1000 patients aged 70-74 years, the policy 'scan all strokes within 48 hours', cost pounds 10,279,728 and achieved 1982.3 QALYS. The most cost-effective strategy was 'scan all immediately' (pounds 9,993,676 and 1982.4 QALYS). The least cost-effective was to 'scan patients on anticoagulants, in a life-threatening condition immediately and the rest within 14 days'. In general, strategies in which most patients were scanned immediately cost least and achieved the most QALYs, as the cost of providing CT (even out of hours) was less than the cost of inpatient care. Increasing independent survival by even a small proportion through early use of aspirin in the majority with ischaemic stroke, avoiding aspirin in those with haemorrhagic stroke, and appropriate early management of those who have not had a stroke, reduced costs and increased QALYs.
Introduction to Seismic Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowe, Charlotte Anne
2017-11-21
Tomography is a method of obtaining an image of a 3d object by observing the behavior of energy transmissions through the object. The image is obtained by Interrogating the object with Energy sources at a variety of Locations and observing the Object’s effects on the energy at a Variety of sensors. Tomography was first Used to build 3-dimensional Scans through Human bodies. These Are called computed Tomographic (ct) scans.
Teymouri, Jessica; Hullar, Timothy E; Holden, Timothy A; Chole, Richard A
2011-08-01
To determine the efficacy of clinical computed tomographic (CT) imaging to verify postoperative electrode array placement in cochlear implant (CI) patients. Nine fresh cadaver heads underwent clinical CT scanning, followed by bilateral CI insertion and postoperative clinical CT scanning. Temporal bones were removed, trimmed, and scanned using micro-CT. Specimens were then dehydrated, embedded in either methyl methacrylate or LR White resin, and sectioned with a diamond wafering saw. Histology sections were examined by 3 blinded observers to determine the position of individual electrodes relative to soft tissue structures within the cochlea. Electrodes were judged to be within the scala tympani, scala vestibuli, or in an intermediate position between scalae. The position of the array could be estimated accurately from clinical CT scans in all specimens using micro-CT and histology as a criterion standard. Verification using micro-CT yielded 97% agreement, and histologic analysis revealed 95% agreement with clinical CT results. A composite, 3-dimensional image derived from a patient's preoperative and postoperative CT images using a clinical scanner accurately estimates the position of the electrode array as determined by micro-CT imaging and histologic analyses. Information obtained using the CT method provides valuable insight into numerous variables of interest to patient performance such as surgical technique, array design, and processor programming and troubleshooting.
Liisanantti, Janne Henrik; Ala-Kokko, Tero Ilmari
2015-12-01
The present study was conducted to explore the impact of computed tomographic (CT) scanning on the diagnostic discrepancy rate. This single-center, retrospective study reviewed postmortem examination results, clinical diagnoses, and radiologic imaging data for patients admitted to the intensive care unit (ICU) in 2008 to 2013. The Goldman criteria were used to classify diagnostic discrepancies. The data of 577 patients who died during their ICU stay were retrieved. The postmortem examination rate was 42.9% (n=248). Significant diagnostic discrepancies (Goldman I and II) were recorded in 24 cases (9.7%). The postmortem examination rate decreased significantly from the first half (n=143; 51.1%) to the second half (n=105; 35.4%) of the study period (P<.0001). Among those with postmortem examinations, the use of antemortem body CT scans increased significantly from the first half (n=59; 41.3%) to the second half (n=64; 51.0%; P=.002) of the study period. The significant diagnostic discrepancy rate did not change with time (8.4% vs 11.4%, respectively; P=.424). The postmortem examination rate has decreased, whereas antemortem CT scans has increased. Copyright © 2015 Elsevier Inc. All rights reserved.
Stoliarova, L G; Varakin, Iu Ia; Vavilov, S B
1981-01-01
Clinical and tomographic examinations of 40 patients with aphasia developed after an ischemic stroke were carried out. In more than half of them no correlation between the aphasia gravity and character on the one hand, and the size and localization of the ischemic focus (or foci) in the brain on the other was noted. With similar character and gravity of the speech disorder the size and localization of the ischemic foci may be different, ad vice versa. It has been shown that the interrelations between the focal pathology of the brain and the character and gravity of speech disorders are very complicated. One should take into consideration the possibility of individual organization of the speech functions, the degree of the speech activity automatism before the disease, and the state of the cerebrovascular system as a whole.
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De; ...
2017-01-28
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
Trace: a high-throughput tomographic reconstruction engine for large-scale datasets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bicer, Tekin; Gursoy, Doga; Andrade, Vincent De
Here, synchrotron light source and detector technologies enable scientists to perform advanced experiments. These scientific instruments and experiments produce data at such scale and complexity that large-scale computation is required to unleash their full power. One of the widely used data acquisition technique at light sources is Computed Tomography, which can generate tens of GB/s depending on x-ray range. A large-scale tomographic dataset, such as mouse brain, may require hours of computation time with a medium size workstation. In this paper, we present Trace, a data-intensive computing middleware we developed for implementation and parallelization of iterative tomographic reconstruction algorithms. Tracemore » provides fine-grained reconstruction of tomography datasets using both (thread level) shared memory and (process level) distributed memory parallelization. Trace utilizes a special data structure called replicated reconstruction object to maximize application performance. We also present the optimizations we have done on the replicated reconstruction objects and evaluate them using a shale and a mouse brain sinogram. Our experimental evaluations show that the applied optimizations and parallelization techniques can provide 158x speedup (using 32 compute nodes) over single core configuration, which decreases the reconstruction time of a sinogram (with 4501 projections and 22400 detector resolution) from 12.5 hours to less than 5 minutes per iteration.« less
Tucker, Melissa D.; Sellon, Rance K.; Tucker, Russell L.; Wills, Tamara B.; Simonsen, Andrea; Maggi, Ricardo G.; Breitschwerdt, Edward B.
2014-01-01
This report describes a 2-year-old collie dog with pulmonary nodules, visualized by computed tomographic (CT) scan, with evidence of Bartonella henselae bacteremia and pyogranulomatous lymphadenitis. Clinical signs resolved with antimicrobial therapy. PMID:25320386
Brain pertechnetate SPECT in perinatal asphyxia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sfakianakis, G.; Curless, R.; Goldberg, R.
1984-01-01
Single photon emission computed tomography of the brain was performed in 6 patients with perinatal asphyxis aged 8-26 days. A single-head (LFOV) commercial SPECT system (Picker) was used and data were acquired 2-3 hr after an IV injection of 1-2 mCi Tc-99m-pertechnetate (360/sup 0/ rotation, 60 views, 64 x 64 matrix, 50K cts/view). Reconstruction in three planes was performed using MDS software (Hanning medium resolution filter, with or without attenuation correction using Sorenson's technique). For each clinical study, a ring type phantom source was used to identify the level of reconstruction noise in the tomographic planes. Abnormalities were found inmore » all patients studied, 3 central (moderate intensity), 2 peripheral (1 severe, 1 moderate) and 1 diffuse (mild intensity). Despite use of oral perchlorate (50 mg) in one patient the choroid plexus was visible. Since attenuation correction tended to amplify noise, the clinical studies were interpreted both with and without this correction. All 3 patients with central lesions were found abnormal on early (1-4 mo) neurologic follow-up examination, whereas the others were normal. No correlation was found between SPECT and 24 hr blood levels of CPK, ammonia, base excess, or the Apgar scores. Ct scans were reported abnormal (3 diffuse, 1 peripheral, 1 central and 1 questionable). Planar scintigrams obtained immediately after SPECT were normal (2), questionable (2) and abnormal (2). Follow-up SPECT brain scintigrams in two of the patients showed partial resolution. SPECT of the brain appears promising in perinatal asphyxia but long-term correlation with patient development is necessary.« less
Akoglu, Haldun; Akoglu, Ebru Unal; Evman, Serdar; Akoglu, Tayfun; Denizbasi, Arzu; Guneysel, Ozlem; Onur, Ozge; Onur, Ender
2012-10-01
Small pneumothoraces (PXs), which are not initially recognized with a chest x-ray film and diagnosed by a thoracic computed tomography (CT), are described as occult PX (OCPX). The objective of this study was to evaluate cervival spine (C-spine) and abdominal CT (ACT) for diagnosing OCPX and overt PX (OVPX). All patients with blunt trauma who presented consecutively to the emergency department during a 26-months period were included. Among all the chest CTs (CCTs) (6,155 patients) conducted during that period, 254 scans were confirmed to have a true PX. The findings in their C-spine CT and ACT were compared with the findings in CCTs. Among these patients, 254 had a diagnosis of PX confirmed with CCT. OCPXs were identified on the chest computed tomographic scan of 128 patients (70.3%), whereas OVPXs were evident in 54 patients (29.7%). Computed tomographic imaging of the C-spine was performed in 74% of patients with OCPX and 66.7% of patients with OVPX trauma. Only 45 (35.2%) cases of OCPX and 42 (77.8%) cases of OVPX were detected by C-spine CT. ACT was performed in almost all patients, and 121 (95.3%) of 127 of these correctly identified an existing OCPX. Sensitivity of C-spine CT and ACT was 35.1% and 96.5%, respectively; specificity was 100% and 100%, respectively. Almost all OCPXs, regardless of intrathoracic location, could be detected by ACT or by combining C-spine and abdominal computed tomographic screening for patients. If the junction of the first and second vertebra is used as the caudad extent, C-spine CT does not have sufficient power to diagnose more than a third of the cases. Diagnostic study, level III.
Assessment of Severity of Ovine Smoke Inhalation Injury by Analysis of Computed Tomographic Scans
2003-09-01
Computerized analysis of three- dimensional reconstructed scans was also performed, based on Hounsfield unit ranges: hyperinflated, 1,000 to 900; normal...the interactive segmentation function of the software. The pulmonary parenchyma was separated into four regions based on the Hounsfield unit (HU...SII) severity. Methods: Twenty anesthetized sheep underwent graded SII: group I, no smoke; group II, 5 smoke units ; group III, 10 units ; and group IV
Computed tomography in cases of coccidioidal meningitis, with clinical correlation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shetter, A.G.; Fischer, D.W.; Flom, R.A.
1985-06-01
Cranial computed tomographic (CT) scans of 22 patients with coccidioidal meningitis were reviewed and their clinical course was analyzed. Abnormalities of the ventricular system or the basilar cisterns or both were present in 16 instances. Although it is not a definitive diagnostic tool, the CT scan is helpful in suggesting a diagnosis of coccidioidal meningitis and in predicting the prognosis of patients affected by the disease. 19 references, 4 figures, 2 tables.
Nael, Kambiz; Khan, Rihan; Choudhary, Gagandeep; Meshksar, Arash; Villablanca, Pablo; Tay, Jennifer; Drake, Kendra; Coull, Bruce M; Kidwell, Chelsea S
2014-07-01
If magnetic resonance imaging (MRI) is to compete with computed tomography for evaluation of patients with acute ischemic stroke, there is a need for further improvements in acquisition speed. Inclusion criteria for this prospective, single institutional study were symptoms of acute ischemic stroke within 24 hours onset, National Institutes of Health Stroke Scale ≥3, and absence of MRI contraindications. A combination of echo-planar imaging (EPI) and a parallel acquisition technique were used on a 3T magnetic resonance (MR) scanner to accelerate the acquisition time. Image analysis was performed independently by 2 neuroradiologists. A total of 62 patients met inclusion criteria. A repeat MRI scan was performed in 22 patients resulting in a total of 84 MRIs available for analysis. Diagnostic image quality was achieved in 100% of diffusion-weighted imaging, 100% EPI-fluid attenuation inversion recovery imaging, 98% EPI-gradient recalled echo, 90% neck MR angiography and 96% of brain MR angiography, and 94% of dynamic susceptibility contrast perfusion scans with interobserver agreements (k) ranging from 0.64 to 0.84. Fifty-nine patients (95%) had acute infarction. There was good interobserver agreement for EPI-fluid attenuation inversion recovery imaging findings (k=0.78; 95% confidence interval, 0.66-0.87) and for detection of mismatch classification using dynamic susceptibility contrast-Tmax (k=0.92; 95% confidence interval, 0.87-0.94). Thirteen acute intracranial hemorrhages were detected on EPI-gradient recalled echo by both observers. A total of 68 and 72 segmental arterial stenoses were detected on contrast-enhanced MR angiography of the neck and brain with k=0.93, 95% confidence interval, 0.84 to 0.96 and 0.87, 95% confidence interval, 0.80 to 0.90, respectively. A 6-minute multimodal MR protocol with good diagnostic quality is feasible for the evaluation of patients with acute ischemic stroke and can result in significant reduction in scan time rivaling that of the multimodal computed tomographic protocol. © 2014 American Heart Association, Inc.
Non-Contact Photoacoustic Imaging Using a Commercial Heterodyne Interferometer
Tian, Chao; Feng, Ting; Wang, Cheng; Liu, Shengchun; Cheng, Qian; Oliver, David E.; Wang, Xueding
2017-01-01
Most current photoacoustic imaging (PAI) systems employ piezoelectric transducers to receive photoacoustic signals, which requires coupling medium to facilitate photoacoustic wave propagation and are not favored in many applications. Here, we report an all-optical non-contact PAI system based on a commercial heterodyne interferometer working at 1550 nm. The interferometer remotely detects ultrasound-induced surface vibration and does not involve any physical contact with the sample. The theoretically predicated and experimentally measured noise equivalent detection limits of the optical sensor are about 4.5 and 810 Pa over 1.2 MHz bandwidth. Using a raster-scan PAI system equipped with the non-contact design, stereotactic boundaries of an artificial tumor in a pig brain were accurately delineated. The non-contact design also enables the tomographic PAI of biological tissue samples in a non-invasive manner. The preliminary results and analyses reveal that the heterodyne interferometer-based non-contact PAI system holds good potential in biomedical imaging. PMID:28210188
Suzuki, Y; Israelski, D M; Dannemann, B R; Stepick-Biek, P; Thulliez, P; Remington, J S
1988-01-01
The present study was performed to develop a serological method for diagnosing toxoplasmic encephalitis in patients with acquired immunodeficiency syndrome (AIDS). The trophozoite form of Toxoplasma gondii, fixed with either Formalin or acetone, was used in a modification of an agglutination method previously shown to differentiate between the acute and the chronic (latent) stages of infection with toxoplasma in immunologically normal persons. By using these antigens in separate tests and evaluating the data for statistical significance, 70% of patients with AIDS with biopsy-proven toxoplasmic encephalitis were distinguished from control, ambulatory patients with AIDS with toxoplasma antibodies but without signs or symptoms of central nervous system involvement. In a separate study, the agglutination tests identified from controls 84% of patients with AIDS with two or more brain lesions detected by computed-tomographic or magnetic-resonance-imaging scans and suspected of having toxoplasmic encephalitis. Thus, these agglutination tests should prove valuable for the noninvasive diagnosis of toxoplasmic encephalitis in patients with AIDS. PMID:3230132
Five cases of neurocysticercosis diagnosed in Sydney.
Walker, J; Chen, S; Packham, D; McIntyre, P
1991-12-01
Cysticercosis, once rare in Australia, is now more frequently diagnosed. This change reflects the countries of origin of new immigrants and the destinations of Australians travelling. Five cases of neurocysticercosis diagnosed at Westmead Hospital in Sydney are described. Two involved Australians, a father and son who had visited eastern and southeastern Asia 10 years before presentation. The other three included immigrants from Chile and India and a visitor from Timor. Ages ranged from 5 to 57 years. Three individuals presented after focal seizures involving the upper limb, one had a long standing history of neurological dysfunction and one suffered from persistent headaches. In all cases computed tomographic scanning (CT) or magnetic resonance imaging (MRI) revealed cystic brain lesions and three of the five were seropositive as well. Four were treated with praziquantel and in one the lesions regressed significantly following treatment. However, the lesion in one case had decreased in size prior to treatment and that in the untreated individual also became smaller.
D'Amato, T; Rochet, T; Dalery, J; Chauchat, J H; Terra, J L; Arteaga, C; Marie-Cardine, M
1992-01-01
Computerized tomography (CT-scan) studies in schizophrenia revealed that some patients have neuromorphological abnormalities. The structural changes consist mainly in lateral and third ventricle enlargement, and in cortical atrophy. The present study evaluates these three changes in 42 schizophrenics aged 18 to 50, compared to 24 healthy controls. Diagnosis were established from information gathered by personal interview with the SADS-LA. Clinical sub-types were evaluated according to the DSM III-R criteria. Moreover, detailed symptoms were rated according to the Positive And Negative Syndrome Scale (PANSS). CT scans were recorded in floppy disks and blindly analyzed. Schizophrenics shown significant higher mean size of lateral and third ventricles, and higher mean anterior cortical atrophy than healthy subjects. Significant differences were also found between subtypes, with more marked abnormalities in the disorganized group. The relationship between brain abnormalities and clinical symptoms recorded with the PANSS, were analysed using Pearson correlates. Positive correlations concerned mainly negative symptoms like blunted affect, emotional withdrawal, difficulties in abstract thinking, passive apathetic social withdrawal and lack of spontaneity of conversation. Positive correlations are also observed with some symptoms classified with the PANSS in the General Psychopathology scale such as mannerism and disorientation. Negative correlation concerned most of PANSS positive symptoms.
Coe, Ryan L; Seibel, Eric J
2012-12-01
We present a method for modeling image formation in optical projection tomographic microscopy (OPTM) using high numerical aperture (NA) condensers and objectives. Similar to techniques used in computed tomography, OPTM produces three-dimensional, reconstructed images of single cells from two-dimensional projections. The model is capable of simulating axial scanning of a microscope objective to produce projections, which are reconstructed using filtered backprojection. Simulation of optical scattering in transmission optical microscopy is designed to analyze all aspects of OPTM image formation, such as degree of specimen staining, refractive-index matching, and objective scanning. In this preliminary work, a set of simulations is performed to examine the effect of changing the condenser NA, objective scan range, and complex refractive index on the final reconstruction of a microshell with an outer radius of 1.5 μm and an inner radius of 0.9 μm. The model lays the groundwork for optimizing OPTM imaging parameters and triaging efforts to further improve the overall system design. As the model is expanded in the future, it will be used to simulate a more realistic cell, which could lead to even greater impact.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Post, M.J.D.; Chan, J.C.; Hensley, G.T.
1983-05-01
The clinical data, histologic findings, and computed tomographic (CT) abnormalities in eight adult Haitians with toxoplasma encephalitis were analyzed retrospectively. Diagnosis was established by identification of Toxoplasma gondii on autopsy in five and brain biopsy in three specimens and subsequently confirmed by the immunoperoxidase method. All these patiens, six of whom had been in the United States for 24 months or less, had severe idiopathic immunodeficiency syndrome. All were lymphopenic and six were on treatment for tuberculosis when the toxoplasma encephalitis developed. All patients were studied with CT when they developed an altered mental status and fever associated with seizuresmore » and/or focal neurologic deficits. Scans before treatment showed multiple intraparenchymal lesions in seven and a single lesion in the thalamus in one. Ring and/or nodular enhancement of the lesions was found in six and hypodense areas in two. Progressions of abnormalities occurred on serial studies. These CT findings that were best shown on axial and coronal thin-section double-dose contrast studies were useful but not diagnostically pathognomonic. In patients with similar clinical presentation CT is recommended to identify focal areas of involvement and to guide brain biopsy or excision so that prompt medical thereapy of this often lethal infection can be instituted.« less
Aging of the midface bony elements: a three-dimensional computed tomographic study.
Shaw, Robert B; Kahn, David M
2007-02-01
The face loses volume as the soft-tissue structures age. In this study, the authors demonstrate how specific bony aspects of the face change with age in both men and women and what impact this may have on the techniques used in facial cosmetic surgery. Facial bone computed tomographic scans were obtained from 60 Caucasian patients (30 women and 30 men). The authors' study population consisted of 10 male and 10 female subjects in each of three age categories. Each computed tomographic scan underwent three-dimensional reconstruction with volume rendering, and the following measurements were obtained: glabellar angle (maximal prominence of glabella to nasofrontal suture), pyriform angle (nasal bone to lateral inferior pyriform aperture), and maxillary angle (superior to inferior maxilla at the articulation of the inferior maxillary wing and alveolar arch). The pyriform aperture area was also obtained. The t test was used to identify any trends between age groups. The glabellar and maxillary angle in both the male and female subjects showed a significant decrease with increasing age. The pyriform angle did not show a significant change between age groups for either sex. There was a significant increase in pyriform aperture area from the young to the middle age group for both sexes. These results suggest that the bony elements of the midface change dramatically with age and, coupled with soft-tissue changes, lead to the appearance of the aged face.
Quantitative evaluation of the memory bias effect in ROC studies with PET/CT
NASA Astrophysics Data System (ADS)
Kallergi, Maria; Pianou, Nicoletta; Georgakopoulos, Alexandros; Kafiri, Georgia; Pavlou, Spiros; Chatziioannou, Sofia
2012-02-01
PURPOSE. The purpose of the study was to evaluate the memory bias effect in ROC experiments with tomographic data and, specifically, in the evaluation of two different PET/CT protocols for the detection and diagnosis of recurrent thyroid cancer. MATERIALS AND METHODS. Two readers participated in an ROC experiment that evaluated tomographic images from 43 patients followed up for thyroid cancer recurrence. Readers evaluated first whole body PET/CT scans of the patients and then a combination of whole body and high-resolution head and neck scans of the same patients. The second set was read twice. Once within 48 hours of the first set and the second time at least a month later. The detection and diagnostic performances of the readers in the three reading sessions were assessed with the DBMMRMC and LABMRMC software using the area under the ROC curve as a performance index. Performances were also evaluated by comparing the number and the size of the detected abnormal foci among the three readings. RESULTS. There was no performance difference between first and second treatments. There were statistically significant differences between first and third, and second and third treatments showing that memory can seriously affect the outcome of ROC studies. CONCLUSION. Despite the fact that tomographic data involve numerous image slices per patient, the memory bias effect is present and substantial and should be carefully eliminated from analogous ROC experiments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakagawa, Motoo, E-mail: lmloltlolol@gmail.com; Ogino, Hiroyuki; Shimohira, Masashi
2009-05-15
A case of acute necrotizing pancreatitis due to Mycoplasma pneumoniae infection was treated in an 8-year-old girl. She experienced acute pancreatitis during treatment for M. pneumoniae. Contrast-enhanced computed tomographic scan revealed necrotizing pancreatitis. The computed tomographic severity index was 8 points (grade E). A protease inhibitor, ulinastatin, was provided via intravenous infusion but was ineffective. Continuous regional arterial infusion therapy was provided with gabexate mesilate (FOY-007, a protease inhibitor) and meropenem trihydrate, and the pancreatitis improved. This case suggests that infusion therapy is safe and useful in treating necrotizing pancreatitis in children.
Monitoring wound healing by multiphoton tomography/endoscopy
NASA Astrophysics Data System (ADS)
König, Karsten; Weinigel, Martin; Bückle, Rainer; Kaatz, Martin; Hipler, Christina; Zens, Katharina; Schneider, Stefan W.; Huck, Volker
2015-02-01
Certified clinical multiphoton tomographs are employed to perform rapid label-free high-resolution in vivo histology. Novel tomographs include a flexible 360° scan head attached to a mechano-optical arm for autofluorescence and SHG imaging as well as rigid two-photon GRIN microendoscope. Mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen can be imaged with submicron resolution in human skin. The system was employed to study the healing of chronic wounds (venous leg ulcer) and acute wounds (curettage of actinic or seborrheic keratosis) on a subcellular level. Furthermore, a flexible sterile foil as interface between wound and focusing optic was tested.
Continuous intrathecal orexin delivery inhibits cataplexy in a murine model of narcolepsy.
Kaushik, Mahesh K; Aritake, Kosuke; Imanishi, Aya; Kanbayashi, Takashi; Ichikawa, Tadashi; Shimizu, Tetsuo; Urade, Yoshihiro; Yanagisawa, Masashi
2018-06-05
Narcolepsy-cataplexy is a chronic neurological disorder caused by loss of orexin (hypocretin)-producing neurons, associated with excessive daytime sleepiness, sleep attacks, cataplexy, sleep paralysis, hypnagogic hallucinations, and fragmentation of nighttime sleep. Currently, human narcolepsy is treated by providing symptomatic therapies, which can be associated with an array of side effects. Although peripherally administered orexin does not efficiently penetrate the blood-brain barrier, centrally delivered orexin can effectively alleviate narcoleptic symptoms in animal models. Chronic intrathecal drug infusion through an implantable pump is a clinically available strategy to treat a number of neurological diseases. Here we demonstrate that the narcoleptic symptoms of orexin knockout mice can be reversed by lumbar-level intrathecal orexin delivery. Orexin was delivered via a chronically implanted intrathecal catheter at the upper lumbar level. The computed tomographic scan confirmed that intrathecally administered contrast agent rapidly moved from the spinal cord to the brain. Intrathecally delivered orexin was detected in the brain by radioimmunoassay at levels comparable to endogenous orexin levels. Cataplexy and sleep-onset REM sleep were significantly decreased in orexin knockout mice during and long after slow infusion of orexin (1 nmol/1 µL/h). Sleep/wake states remained unchanged both quantitatively as well as qualitatively. Intrathecal orexin failed to induce any changes in double orexin receptor-1 and -2 knockout mice. This study supports the concept of intrathecal orexin delivery as a potential therapy for narcolepsy-cataplexy to improve the well-being of patients.
NASA Astrophysics Data System (ADS)
Staton, Robert J.; Lee, Choonik; Lee, Choonsik; Williams, Matt D.; Hintenlang, David E.; Arreola, Manuel M.; Williams, Jonathon L.; Bolch, Wesley E.
2006-10-01
In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52° and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.
NASA Astrophysics Data System (ADS)
Kostencka, Julianna; Kozacki, Tomasz; Hennelly, Bryan; Sheridan, John T.
2017-06-01
Holographic tomography (HT) allows noninvasive, quantitative, 3D imaging of transparent microobjects, such as living biological cells and fiber optics elements. The technique is based on acquisition of multiple scattered fields for various sample perspectives using digital holographic microscopy. Then, the captured data is processed with one of the tomographic reconstruction algorithms, which enables 3D reconstruction of refractive index distribution. In our recent works we addressed the issue of spatially variant accuracy of the HT reconstructions, which results from the insufficient model of diffraction that is applied in the widely-used tomographic reconstruction algorithms basing on the Rytov approximation. In the present study, we continue investigating the spatially variant properties of the HT imaging, however, we are now focusing on the limited spatial size of holograms as a source of this problem. Using the Wigner distribution representation and the Ewald sphere approach, we show that the limited size of the holograms results in a decreased quality of tomographic imaging in off-center regions of the HT reconstructions. This is because the finite detector extent becomes a limiting aperture that prohibits acquisition of full information about diffracted fields coming from the out-of-focus structures of a sample. The incompleteness of the data results in an effective truncation of the tomographic transfer function for the out-of-center regions of the tomographic image. In this paper, the described effect is quantitatively characterized for three types of the tomographic systems: the configuration with 1) object rotation, 2) scanning of the illumination direction, 3) the hybrid HT solution combing both previous approaches.
Lateral resolution testing of a novel developed confocal microscopic imaging system
NASA Astrophysics Data System (ADS)
Zhang, Xin; Zhang, Yunhai; Chang, Jian; Huang, Wei; Xue, Xiaojun; Xiao, Yun
2015-10-01
Laser scanning confocal microscope has been widely used in biology, medicine and material science owing to its advantages of high resolution and tomographic imaging. Based on a set of confirmatory experiments and system design, a novel confocal microscopic imaging system is developed. The system is composed of a conventional fluorescence microscope and a confocal scanning unit. In the scanning unit a laser beam coupling module provides four different wavelengths 405nm 488nm 561nm and 638nm which can excite a variety of dyes. The system works in spot-to-spot scanning mode with a two-dimensional galvanometer. A 50 microns pinhole is used to guarantee that stray light is blocked and only the fluorescence signal from the focal point can be received . The three-channel spectral splitter is used to perform fluorescence imaging at three different working wavelengths simultaneously. The rat kidney tissue slice is imaged using the developed confocal microscopic imaging system. Nucleues labeled by DAPI and kidney spherule curved pipe labeled by Alexa Fluor 488 can be imaged clearly and respectively, realizing the distinction between the different components of mouse kidney tissue. The three-dimensional tomographic imaging of mouse kidney tissue is reconstructed by several two-dimensional images obtained in different depths. At last the resolution of the confocal microscopic imaging system is tested quantitatively. The experimental result shows that the system can achieve lateral resolution priority to 230nm.
Evaluation of Oral Anticoagulant-Associated Intracranial Parenchymal Hematomas Using CT Findings.
Gökçe, E; Beyhan, M; Acu, B
2015-06-01
Intracranial hemorrhage (ICH) is one of the most serious and lethal complications of anticoagulants with a reported incidence of 5-18.5 %. Computed tomographic (CT) findings, should be carefully studied because early diagnosis and treatment of oral anticoagulant use-associated hematomas are vitally important. In the present study, CT findings of intraparenchymal hematomas associated with anticoagulant and antihypertensive use are presented. This study included 45 patients (25 men, 20 women) under anticoagulant (21 patients) or antihypertensive (24 patients) treatment who had brain CT examinations due to complaints and findings suggesting cerebrovascular disease during July 2010-October 2013 period. CT examinations were performed to determine hematoma volumes and presence of swirl sign, hematocrit effect, mid-line shift effect, and intraventricular extension. The patients were 40-89 years of age. In four cases, a total of 51 intraparenchymal hematomas (42 cerebral, 7 cerebellar and 2 brain stem) were detected in multiple foci. Hematoma volumes varied from 0.09 to 284.00 ml. Swirl sign was observed in 87.5 and 63.0 % of OAC-associated ICHs and non-OAC-associated ICHs, respectively. In addition, hematocrit effect was observed in 41.6 % of OAC-associated and in 3.7 % of non-OAC-associated ICHs. Volume increases were observed in all 19 hematomas where swirl sign was detected, and follow-up CT scanning was conducted. Mortality of OAC-associated ICHs was correlated with initial volumes of hematoma, mid-line shift amount, and intraventricular extension. Detection of hematocrit effect by CT scanning of intracranial hematomas should be cautionary in oral anticoagulant use, while detection of swirl sign should be suggestive of active hemorrhage.
Cerebral blood flow tomography with xenon-133
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.
1985-10-01
Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This articlemore » discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.« less
NASA Astrophysics Data System (ADS)
Ryseva, Ekaterina; Zhukova, Ekaterina
2013-05-01
The wide field and spectral methods of optical coherence microscopy were used for extensive studying the photographs printed in the early 20th century. Tomographic images (B-scans) of photo and paper materials are presented and discussed.
Kubo, S; Nakata, H; Sugauchi, Y; Yokota, N; Yoshimine, T
2000-05-01
The preoperative localization of superficial intracranial lesions is often necessary for accurate burr hole placement or craniotomy siting. It is not always easy, however, to localize the lesions over the scalp working only from computed tomographic images. We developed a simple method for such localization using a laser pointer during the preoperative computed tomographic examination. The angle of incidence, extending from a point on the scalp to the center of the computed tomographic image, is measured by the software included with the scanner. In the gantry, at the same angle as on the image, a laser is beamed from a handmade projector onto the patient's scalp toward the center of the gantry. The point illuminated on the patient's head corresponds to that on the image. The device and the method are described in detail herein. We applied this technique to mark the area for the craniotomy before surgery in five patients with superficial brain tumors. At the time of surgery, it was confirmed that the tumors were circumscribed precisely. The technique is easy to perform and useful in the preoperative planning for a craniotomy. In addition, the device is easily constructed and inexpensive.
Lin, Kun-Ju; Hsu, Wen-Chuin; Hsiao, Ing-Tsung; Wey, Shiaw-Pyng; Jin, Lee-Way; Skovronsky, Daniel; Wai, Yau-Yau; Chang, Hsiu-Ping; Lo, Chuan-Wei; Yao, Cheng Hsiang; Yen, Tzu-Chen; Kung, Mei-Ping
2010-05-01
The compound (E)-4-(2-(6-(2-(2-(2-(18)F-fluoroethoxy)ethoxy)ethoxy) pyridin-3-yl)vinyl)-N-methylbenzenamine ([(18)F]AV-45) is a novel radiopharmaceutical capable of selectively binding to beta-amyloid (A beta) plaques. This pilot study reports the safety, biodistribution, and radiation dosimetry of [(18)F]AV-45 in human subjects. In vitro autoradiography and fluorescent staining of postmortem brain tissue from patients with Alzheimer's disease (AD) and cognitively healthy subjects were performed to assess the specificity of the tracer. Biodistribution was assessed in three healthy elderly subjects (mean age: 60.0+/-5.2 years) who underwent 3-h whole-body positron emission tomography (PET)/computed tomographic (CT) scans after a bolus injection of 381.9+/-13.9 MBq of [(18)F]AV-45. Another six subjects (three AD patients and three healthy controls, mean age: 67.7+/-13.6 years) underwent brain PET studies. Source organs were delineated on PET/CT. All subjects underwent magnetic resonance imaging (MRI) for obtaining structural information. In vitro autoradiography revealed exquisitely high specific binding of [(18)F]AV-45 to postmortem AD brain sections, but not to the control sections. There were no serious adverse events throughout the study period. The peak uptake of the tracer in the brain was 5.12+/-0.41% of the injected dose. The highest absorbed organ dose was to the gallbladder wall (184.7+/-78.6 microGy/MBq, 4.8 h voiding interval). The effective dose equivalent and effective dose values for [(18)F]AV-45 were 33.8+/-3.4 microSv/MBq and 19.3+/-1.3 microSv/MBq, respectively. [(18)F]AV-45 binds specifically to A beta in vitro, and is a safe PET tracer for studying A beta distribution in human brain. The dosimetry is suitable for clinical and research application. (c) 2010 Elsevier Inc. All rights reserved.
Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction
Xia, Rongmin; Li, Xu; He, Bin
2008-01-01
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, we have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, we demonstrated 3-dimensional MAT-MI imaging in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue. PMID:19169372
Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction
NASA Astrophysics Data System (ADS)
Xia, Rongmin; Li, Xu; He, Bin
2007-08-01
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, the authors have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, they demonstrated a three-dimensional MAT-MI imaging approach in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue.
Magnetoacoustic tomographic imaging of electrical impedance with magnetic induction.
Xia, Rongmin; Li, Xu; He, Bin
2007-08-22
Magnetoacoustic tomography with magnetic induction (MAT-MI) is a recently introduced method for imaging tissue electrical impedance properties by integrating magnetic induction and ultrasound measurements. In the present study, we have developed a focused cylindrical scanning mode MAT-MI system and the corresponding reconstruction algorithms. Using this system, we demonstrated 3-dimensional MAT-MI imaging in a physical phantom, with cylindrical scanning combined with ultrasound focusing, and the ability of MAT-MI in imaging electrical conductivity properties of biological tissue.
Computed tomographic findings and treatment of a bull with pituitary gland abscess.
Braun, Ueli; Malbon, Alexandra; Kochan, Manon; Riond, Barbara; Janett, Fredi; Iten, Cornelia; Dennler, Matthias
2017-01-13
In cattle, the prognosis of brain abscess is unfavourable and treatment is therefore not recommended. To the knowledge of the authors, there has been no report of successful treatment of a brain abscess in cattle.This report describes the clinical, computed tomographic and postmortem findings in a Holstein-Friesian bull with a hypophyseal abscess. The main clinical findings were generalised ataxia, ptyalism, prolapse of the tongue, dropped jaw, dysphagia, head tilt and unilateral ptosis. Cerebrospinal fluid evaluation revealed 2437 leukocytes/µl and severe pleocytosis. CT examination of the head showed a cavitary lesion consistent with an abscess in the hypophysis. Treatment consisted of gentamicin and flunixin meglumine for 3 days and amoxicillin for 40 days. The neurological signs resolved within 8 days of the start of treatment. The bull was slaughtered 11 months later because of infertility, and a postmortem examination was carried out. Histologically, a mild chronic non suppurative meningoencephalitis restricted to the ventral diencephalon was diagnosed. In addition, there was mild to moderate multifocal chronic lymphoplasmacytic hypophysitis with mild multifocal fibrosis. This case report stresses the significance of CT in confirming the clinical and laboratory diagnosis of central nervous system disorders in cattle and for localising brain lesions. Treatment of the brain abscess resulted, with respect to the central nervous disorder, in a successful outcome and was encouraging considering that most cases have an unfavourable prognosis.
Baskerville, Jerry Ray; Herrick, John
2012-02-01
This study focuses on clinically assigned prospective estimated pretest probability and pretest perception of legal risk as independent variables in the ordering of multidetector computed tomographic (MDCT) head scans. Our primary aim is to measure the association between pretest probability of a significant finding and pretest perception of legal risk. Secondarily, we measure the percentage of MDCT scans that physicians would not order if there was no legal risk. This study is a prospective, cross-sectional, descriptive analysis of patients 18 years and older for whom emergency medicine physicians ordered a head MDCT. We collected a sample of 138 patients subjected to head MDCT scans. The prevalence of a significant finding in our population was 6%, yet the pretest probability expectation of a significant finding was 33%. The legal risk presumed was even more dramatic at 54%. These data support the hypothesis that physicians presume the legal risk to be significantly higher than the risk of a significant finding. A total of 21% or 15% patients (95% confidence interval, ±5.9%) would not have been subjected to MDCT if there was no legal risk. Physicians overestimated the probability that the computed tomographic scan would yield a significant result and indicated an even greater perceived medicolegal risk if the scan was not obtained. Physician test-ordering behavior is complex, and our study queries pertinent aspects of MDCT testing. The magnification of legal risk vs the pretest probability of a significant finding is demonstrated. Physicians significantly overestimated pretest probability of a significant finding on head MDCT scans and presumed legal risk. Copyright © 2012 Elsevier Inc. All rights reserved.
Reversible suprasellar pituitary mass secondary to hypothyroidism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atchison, J.A.; Lee, P.A.; Albright, A.L.
1989-12-08
Sellar enlargement and suprasellar extension of a pituitary mass, demonstrated by magnetic resonance imaging or computed tomographic scanning in three children with primary hypothyroidism, resolved after treatment with levothyroxine sodium. This condition, a logical consequence of the pathogenesis of primary hypothyroidism, must be considered in patients with pituitary and suprasellar masses.
Endoscopic laser range scanner for minimally invasive, image guided kidney surgery
NASA Astrophysics Data System (ADS)
Friets, Eric; Bieszczad, Jerry; Kynor, David; Norris, James; Davis, Brynmor; Allen, Lindsay; Chambers, Robert; Wolf, Jacob; Glisson, Courtenay; Herrell, S. Duke; Galloway, Robert L.
2013-03-01
Image guided surgery (IGS) has led to significant advances in surgical procedures and outcomes. Endoscopic IGS is hindered, however, by the lack of suitable intraoperative scanning technology for registration with preoperative tomographic image data. This paper describes implementation of an endoscopic laser range scanner (eLRS) system for accurate, intraoperative mapping of the kidney surface, registration of the measured kidney surface with preoperative tomographic images, and interactive image-based surgical guidance for subsurface lesion targeting. The eLRS comprises a standard stereo endoscope coupled to a steerable laser, which scans a laser fan beam across the kidney surface, and a high-speed color camera, which records the laser-illuminated pixel locations on the kidney. Through calibrated triangulation, a dense set of 3-D surface coordinates are determined. At maximum resolution, the eLRS acquires over 300,000 surface points in less than 15 seconds. Lower resolution scans of 27,500 points are acquired in one second. Measurement accuracy of the eLRS, determined through scanning of reference planar and spherical phantoms, is estimated to be 0.38 +/- 0.27 mm at a range of 2 to 6 cm. Registration of the scanned kidney surface with preoperative image data is achieved using a modified iterative closest point algorithm. Surgical guidance is provided through graphical overlay of the boundaries of subsurface lesions, vasculature, ducts, and other renal structures labeled in the CT or MR images, onto the eLRS camera image. Depth to these subsurface targets is also displayed. Proof of clinical feasibility has been established in an explanted perfused porcine kidney experiment.
Noninvasive coronary artery angiography using electron beam computed tomography
NASA Astrophysics Data System (ADS)
Rumberger, John A.; Rensing, Benno J.; Reed, Judd E.; Ritman, Erik L.; Sheedy, Patrick F., II
1996-04-01
Electron beam computed tomography (EBCT), also known as ultrafast-CT or cine-CT, uses a unique scanning architecture which allows for multiple high spatial resolution electrocardiographic triggered images of the beating heart. A recent study has demonstrated the feasibility of qualitative comparisons between EBCT derived 3D coronary angiograms and invasive angiography. Stenoses of the proximal portions of the left anterior descending and right coronary arteries were readily identified, but description of atherosclerotic narrowing in the left circumflex artery (and distal epicardial disease) was not possible with any degree of confidence. Although these preliminary studies support the notion that this approach has potential, the images overall were suboptimal for clinical application as an adjunct to invasive angiography. Furthermore, these studies did not examine different methods of EBCT scan acquisition, tomographic slice thicknesses, extent of scan overlap, or other segmentation, thresholding, and interpolation algorithms. Our laboratory has initiated investigation of these aspects and limitations of EBCT coronary angiography. Specific areas of research include defining effects of cardiac orientation; defining the effects of tomographic slice thickness and intensity (gradient) versus positional (shaped based) interpolation; and defining applicability of imaging each of the major epicardial coronary arteries for quantitative definition of vessel size, cross-sectional area, taper, and discrete vessel narrowing.
Jang, Hansol; Lim, Gukbin; Hong, Keum-Shik; Cho, Jaedu; Gulsen, Gultekin; Kim, Chang-Seok
2017-11-28
Diffuse optical tomography (DOT) has been studied for use in the detection of breast cancer, cerebral oxygenation, and cognitive brain signals. As optical imaging studies have increased significantly, acquiring imaging data in real time has become increasingly important. We have developed frequency-division multiplexing (FDM) DOT systems to analyze their performance with respect to acquisition time and imaging quality, in comparison with the conventional time-division multiplexing (TDM) DOT. A large tomographic area of a cylindrical phantom 60 mm in diameter could be successfully reconstructed using both TDM DOT and FDM DOT systems. In our experiment with 6 source-detector (S-D) pairs, the TDM DOT and FDM DOT systems required 6.18 and 1 s, respectively, to obtain a single tomographic data set. While the absorption coefficient of the reconstruction image was underestimated in the case of the FDM DOT, we experimentally confirmed that the abnormal region can be clearly distinguished from the background phantom using both methods.
NASA Astrophysics Data System (ADS)
Zhou, Chao; Yu, Guoqiang; Furuya, Daisuke; Greenberg, Joel; Yodh, Arjun; Durduran, Turgut
2006-02-01
Diffuse optical correlation methods were adapted for three-dimensional (3D) tomography of cerebral blood flow (CBF) in small animal models. The image reconstruction was optimized using a noise model for diffuse correlation tomography which enabled better data selection and regularization. The tomographic approach was demonstrated with simulated data and during in-vivo cortical spreading depression (CSD) in rat brain. Three-dimensional images of CBF were obtained through intact skull in tissues(~4mm) deep below the cortex.
CT Imaging of Hardwood Logs for Lumber Production
Daniel L. Schmoldt; Pei Li; A. Lynn Abbott
1996-01-01
Hardwood sawmill operators need to improve the conversion of raw material (logs) into lumber. Internal log scanning provides detailed information that can aid log processors in improving lumber recovery. However, scanner data (i.e. tomographic images) need to be analyzed prior to presentation to saw operators. Automatic labeling of computer tomography (CT) images is...
Diagnostic cardiology: Noninvasive imaging techniques
DOE Office of Scientific and Technical Information (OSTI.GOV)
Come, P.C.
1985-01-01
This book contains 23 chapters. Some of the chapter titles are: The chest x-ray and cardiac series; Computed tomographic scanning of the heart, coronary arteries, and great vessels; Digital subtraction angiography in the assessment of cardiovascular disease; Magnetic resonance: technique and cardiac applications; Basics of radiation physics and instrumentation; and Nuclear imaging: the assessment of cardiac performance.
[A Case of Pancreatic Neuroendocrine Tumor with Necrolytic Migratory Erythema].
Hijikawa, Takeshi; Kitade, Hiroaki; Yanagida, Hidesuke; Yamada, Masanori; Yoshioka, Kazuhiko; Shijimaya, Takako; Kiyohara, Takahiro; Uemura, Yoshiko; Kon, Masanori
2017-10-01
A 45-year-old man was admitted because of necrolytic migratory erythema. A computed tomographic scan of the abdomen revealed a 4.5cm mass in the tail of the pancreas. We performed distal pancreatectomy and splenectomy, and a definitive diagnosis of pancreatic neuroendocrine tumor(WHO class grade 2)was made histopathologically.
Fujii, Takeshi; Watanabe, Kota; Toyama, Yoshiaki; Matsumoto, Morio
2014-09-01
Case report. To describe a case in which a patient regained pulmonary function, assessed by ventilation-perfusion scans, after undergoing posterior vertebral column resection (VCR) to correct severe adolescent idiopathic scoliosis (AIS) with associated pulmonary dysfunction. Pulmonary improvement after corrective surgery for AIS has been reported. Ventilation-perfusion scans are useful for assessing pulmonary function. However, these scans have not been used to examine the recovery of pulmonary function after VCR for severe AIS with pulmonary dysfunction. A patient was described in whom ventilation-perfusion scans were used to examine improvements in impaired air ventilation and blood perfusion after VCR surgery for severe AIS. The relevant literature was reviewed. An 18-year-old male came to Keio University Hospital with exertional dyspnea associated with severe AIS. Radiographs showed severe scoliosis of 91° at T6-T12, and hypokyphosis of 6° at T5-T12. Computed tomographic scans showed narrowing of the thoracic cage on the convex side of the main thoracic curve, with the vertebral bodies at the apex of the curve obstructing the right main bronchus. Pulmonary function tests revealed a percent vital capacity of 44% and percent forced expiratory volume in 1 second of 76%. A ventilation-perfusion scan showed decreased air ventilation and blood perfusion in the right lung. The patient underwent posterior correction surgery, which used segmental pedicle screws with a VCR at T9. The scoliosis was corrected to 28°, and the kyphosis to 14°. Postoperative computed tomographic scans showed expansion of the right main bronchus. A ventilation-perfusion scan conducted 1 year after surgery showed clear improvement in both ventilation and blood perfusion in the right lung. The patient's forced expiratory volume in 1 second had increased to 91%. This is the first report in which ventilation-perfusion scans were used to examine improvements in impaired air ventilation and blood perfusion after VCR surgery in a patient with severe AIS. N/A.
Misdiagnosis of acute peripheral vestibulopathy in central nervous ischemic infarction.
Braun, Eva Maria; Tomazic, Peter Valentin; Ropposch, Thorsten; Nemetz, Ulrike; Lackner, Andreas; Walch, Christian
2011-12-01
Vertigo is a very common symptom at otorhinolaryngology (ENT), neurological, and emergency units, but often, it is difficult to distinguish between vertigo of peripheral and central origin. We conducted a retrospective analysis of a hospital database, including all patients admitted to the ENT University Hospital Graz after neurological examination, with a diagnosis of peripheral vestibular vertigo and subsequent diagnosis of central nervous infarction as the actual cause for the vertigo. Twelve patients were included in this study. All patients with acute spinning vertigo after a thorough neurological examination and with uneventful computed tomographic scans were referred to our ENT department. Nine of them presented with horizontal nystagmus. Only 1 woman experienced additional hearing loss. The mean diagnostic delay to the definite diagnosis of a central infarction through magnetic resonance imaging was 4 days (SD, 2.3 d). A careful otologic and neurological examination, including the head impulse test and caloric testing, is mandatory. Because ischemic events cannot be diagnosed in computed tomographic scans at an early stage, we strongly recommend to perform cranial magnetic resonance imaging within 48 hours from admission if vertigo has not improved under conservative treatment.
NASA Astrophysics Data System (ADS)
Cha, Don J.; Cha, Soyoung S.
1995-09-01
A computational tomographic technique, termed the variable grid method (VGM), has been developed for improving interferometric reconstruction of flow fields under ill-posed data conditions of restricted scanning and incomplete projection. The technique is based on natural pixel decomposition, that is, division of a field into variable grid elements. The performances of two algorithms, that is, original and revised versions, are compared to investigate the effects of the data redundancy criteria and seed element forming schemes. Tests of the VGMs are conducted through computer simulation of experiments and reconstruction of fields with a limited view angel of 90 degree(s). The temperature fields at two horizontal sections of a thermal plume of two interacting isothermal cubes, produced by a finite numerical code, are analyzed as test fields. The computer simulation demonstrates the superiority of the revised VGM to either the conventional fixed grid method or the original VGM. Both the maximum and average reconstruction errors are reduced appreciably. The reconstruction shows substantial improvement in the regions with dense scanning by probing rays. These regions are usually of interest in engineering applications.
Bendyk-Szeffer, Maja; Łagocka, Ryta; Trusewicz, Matylda; Lipski, Mariusz; Buczkowska-Radlińska, Jadwiga
2015-02-01
An extensive perforating internal root resorption accompanied by apical periodontitis and odontogenic sinus mucositis was detected on preoperative cone-beam computed tomographic scans in a first maxillary molar. After the chemomechanical debridement of the root canals, calcium hydroxide was placed as a temporary dressing for 7 days. Mineral trioxide aggregate was used to fill the perforation site with the aid of a surgical microscope. At the next visit, the root with the resorption defect was filled with warm vertical compaction of gutta-percha. A control cone-beam computed tomographic scan acquired 6 months after the endodontic treatment revealed complete resolution of the sinus retention cyst. Moreover, the patient's frequent otolaryngologic disturbances ceased. The tooth was functional with satisfactory clinical and radiographic results after 12 months. Based on the results of this case, successful repair of an extensive, perforating internal resorption with mineral trioxide aggregate may lead to complete resolution of apical periodontitis and maxillary sinus retention cyst. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, G.S.; Dewey, S.L.; Logan, J.
1994-05-01
Our previous studies have shown that the interaction between serotonin and dopamine can be measured with C-11 raclopride and PET in the baboon brain. A series of studies was undertaken to extend dim findings to the normal human brain. PET studies were conducted in male control subjects (n=8) using the CTI 931 tomograph. Two C-11 raclopride scans were performed, prior to and 180 minutes following administration of the selective serotonin releasing agent, fenfluramine (60mg/PO). The neuroendocrine response to fenfluramine challenge is commonly used in psychiatric research as an index of serotonin activity. The C-11 raclopride data were analyzed with themore » distribution volume method. For the group of subjects, an increase was observed in the striatum to cerebellum ratio (specific to non-specific binding ratio), in excess of the test-retest variability of the ligand. Variability in response was observed across subjects. These results are consistent with our previous findings in the baboon that citalopram administration increased C-11 raclopride binding, consistent with a decrease in endogenous dopamine. In vivo microdialysis studies in freely moving rats confirmed that citalopram produces a time-dependent decrease in extracellular dopamine levels, consistent with the PET results. In vivo PET studies of the serotonin-dopamine interaction are relevant to the evaluation of etiologic and therapeutic mechanisms in schizophrenia and affective disorder.« less
3D quantification of brain microvessels exposed to heavy particle radiation
NASA Astrophysics Data System (ADS)
Hintermüller, C.; Coats, J. S.; Obenaus, A.; Nelson, G.; Krucker, T.; Stampanoni, M.
2009-09-01
Space radiation with high energy particles and cosmic rays presents a significant hazard to spaceflight crews. Recent reviews of the health risk to astronauts from ionizing radiation concluded to establish a level of risk which may indicate the possible performance decrements and decreased latency of late dysfunction syndromes (LDS) of the brain. A hierarchical imaging approach developed at ETH Zürich and PSI, which relies on synchrotron based X-ray Tomographic Microscopy (SRXTM), was used to visualize and analyze 3D vascular structures down to the capillary level in their precise anatomical context. Various morphological parameters, such as overall vessel volume, vessel thickness and spacing, are extracted to characterize the vascular structure within a region of interest. For a first quantification of the effect of high energy particles on the vasculature we scanned a set of 6 animals, all of same age. The animals were irradiated with 1 Gy, 2 Gy and 4 Gy of 600MeV 56Fe heavy particles simulating the space radiation environment. We found that with increasing dose the diameter of vessels and the overall vessel volume are decreased whereas the vessel spacing is increased. As these parameters reflect blood flow in three-dimensional space they can be used as indicators for the degree of vascular efficiency which can have an impact on the function and development of lung tissue or tumors.
Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto
2014-01-01
This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic patients.
Does MRI scan acceleration affect power to track brain change?
Ching, Christopher R K; Hua, Xue; Hibar, Derrek P; Ward, Chadwick P; Gunter, Jeffrey L; Bernstein, Matt A; Jack, Clifford R; Weiner, Michael W; Thompson, Paul M
2015-01-01
The Alzheimer's Disease Neuroimaging Initiative recently implemented accelerated T1-weighted structural imaging to reduce scan times. Faster scans may reduce study costs and patient attrition by accommodating people who cannot tolerate long scan sessions. However, little is known about how scan acceleration affects the power to detect longitudinal brain change. Using tensor-based morphometry, no significant difference was detected in numerical summaries of atrophy rates from accelerated and nonaccelerated scans in subgroups of patients with Alzheimer's disease, early or late mild cognitive impairment, or healthy controls over a 6- and 12-month scan interval. Whole-brain voxelwise mapping analyses revealed some apparent regional differences in 6-month atrophy rates when comparing all subjects irrespective of diagnosis (n = 345). No such whole-brain difference was detected for the 12-month scan interval (n = 156). Effect sizes for structural brain changes were not detectably different in accelerated versus nonaccelerated data. Scan acceleration may influence brain measures but has minimal effects on tensor-based morphometry-derived atrophy measures, at least over the 6- and 12-month intervals examined here. Copyright © 2015 Elsevier Inc. All rights reserved.
Yamatsuji, Tomoki; Ishida, Naomasa; Takaoka, Munenori; Hayashi, Jiro; Yoshida, Kazuhiro; Shigemitsu, Kaori; Urakami, Atsushi; Haisa, Minoru; Naomoto, Yoshio
2017-01-01
Of 129 esophagectomies at our institute from June 2010 to March 2015, we experienced three preoperative positron emission tomography-computed tomographic (PET/CT) false positives. Bone metastasis was originally suspected in 2 cases, but they were later found to be bone metastasis negative after a preoperative bone biopsy and clinical course observation. The other cases suspected of mediastinal lymph node metastasis were diagnosed as inflammatory lymphadenopathy by a pathological examination of the removed lymph nodes. Conducting a PET/CT is useful when diagnosing esophageal cancer metastasis, but we need to be aware of the possibility of false positives. Therapeutic decisions should be made based on appropriate and accurate diagnoses, with pathological diagnosis actively introduced if necessary. PMID:28469502
Advanced Ultrasonic Tomograph of Children's Bones
NASA Astrophysics Data System (ADS)
Lasaygues, Philippe; Lefebvre, Jean-Pierre; Guillermin, Régine; Kaftandjian, Valérie; Berteau, Jean-Philippe; Pithioux, Martine; Petit, Philippe
This study deals with the development of an experimental device for performing ultrasonic computed tomography (UCT) on bone in pediatric degrees. The children's bone tomographs obtained in this study, were based on the use of a multiplexed 2-D ring antenna (1 MHz and 3 MHz) designed for performing electronic and mechanical scanning. Although this approach is known to be a potentially valuable means of imaging objects with similar acoustical impedances, problems arise when quantitative images of more highly contrasted media such as bones are required. Various strategies and various mathematical procedures for modeling the wave propagation based on Born approximations have been developed at our laboratory, which are suitable for use with pediatric cases. Inversions of the experimental data obtained are presented.
Conversion Disorder; an Unusual Etiology of Unilateral Foot Drop.
Ayaz, Saeed Bin; Matee, Sumeera; Malik, Riffat; Ahmad, Khalil
2015-06-01
Foot drop is generally a consequence of common peroneal or sciatic nerve injury or L5 radiculopathy but rarely, it can be a manifestation of conversion disorder. A 24-year-old male presented with a foot drop on left side that developed overnight. He had difficulty walking with a trunk tilt towards right side and numbness in left leg up to mid-thigh. The initial diagnosis by the general practitioner was common peroneal nerve injury, which was not supported by the subsequent detailed examination in the physiatry department. Routine laboratory investigations, computed tomographic scan of brain and electrophysiological evaluation were normal. In a multidisciplinary team evaluation involving a psychiatrist, he was diagnosed to be suffering from conversion disorder and was advised gait retraining, cognitive and behavioral therapy and tablet venlafaxine. By sixth day of treatment, the patient was able to walk independently with a normal gait pattern and reported complete recovery of his symptoms. In the absence of an identifiable organic cause of foot drop in a patient, conversion disorder may be considered necessitating early intervention by a psychiatrist.
Digital holographic tomography based on spectral interferometry.
Yu, Lingfeng; Chen, Zhongping
2007-10-15
A digital holographic tomography system has been developed with the use of an inexpensive broadband light source and a fiber-based spectral interferometer. Multiple synthesized holograms (or object wave fields) of different wavelengths are obtained by transversely scanning a probe beam. The acquisition speed is improved compared with conventional wavelength-scanning digital holographic systems. The optical field of a volume around the object location is calculated by numerical diffraction from each synthesized hologram, and all such field volumes are numerically superposed to create the three-dimensional tomographic image. Experiments were performed to demonstrate the idea.
Brain activation during human male ejaculation revisited.
Georgiadis, Janniko R; Reinders, A A T Simone; Van der Graaf, Ferdinand H C E; Paans, Anne M J; Kortekaas, Rudie
2007-04-16
In a prior [O]-H2O positron emission tomographic study we reported brain regions involved in human male ejaculation. Here, we used another, more recently acquired data set to evaluate the methodological approach of this previous study, and discovered that part of the reported activation pattern was not related to ejaculation. With a new analysis of these ejaculation data, we now demonstrate ejaculation-related activations in the deep cerebellar nuclei (dentate nucleus), anterior vermis, pons, and ventrolateral thalamus, and, most importantly, ejaculation-related deactivations throughout the prefrontal cortex. This revision offers a new and more accurate insight into the brain regions involved in human male ejaculation.
Wilson, J Adam; Shutter, Lori A; Hartings, Jed A
2013-01-01
Neuromonitoring in patients with severe brain trauma and stroke is often limited to intracranial pressure (ICP); advanced neuroscience intensive care units may also monitor brain oxygenation (partial pressure of brain tissue oxygen, P(bt)O(2)), electroencephalogram (EEG), cerebral blood flow (CBF), or neurochemistry. For example, cortical spreading depolarizations (CSDs) recorded by electrocorticography (ECoG) are associated with delayed cerebral ischemia after subarachnoid hemorrhage and are an attractive target for novel therapeutic approaches. However, to better understand pathophysiologic relations and realize the potential of multimodal monitoring, a common platform for data collection and integration is needed. We have developed a multimodal system that integrates clinical, research, and imaging data into a single research and development (R&D) platform. Our system is adapted from the widely used BCI2000, a brain-computer interface tool which is written in the C++ language and supports over 20 data acquisition systems. It is optimized for real-time analysis of multimodal data using advanced time and frequency domain analyses and is extensible for research development using a combination of C++, MATLAB, and Python languages. Continuous streams of raw and processed data, including BP (blood pressure), ICP, PtiO2, CBF, ECoG, EEG, and patient video are stored in an open binary data format. Selected events identified in raw (e.g., ICP) or processed (e.g., CSD) measures are displayed graphically, can trigger alarms, or can be sent to researchers or clinicians via text message. For instance, algorithms for automated detection of CSD have been incorporated, and processed ECoG signals are projected onto three-dimensional (3D) brain models based on patient magnetic resonance imaging (MRI) and computed tomographic (CT) scans, allowing real-time correlation of pathoanatomy and cortical function. This platform will provide clinicians and researchers with an advanced tool to investigate pathophysiologic relationships and novel measures of cerebral status, as well as implement treatment algorithms based on such multimodal measures.
Sakai, Sharleen T; Whitt, Blake; Arsznov, Bradley M; Lundrigan, Barbara L
2018-04-10
The purpose of this study was to examine the pattern of postnatal brain growth in two wild canid species: the coyote (Canis latrans) and gray wolf (Canis lupus). Adult regional and total brain volume differences were also compared between the two species as well as within each species by sex. Three-dimensional virtual endocasts of endocranial airspace were created from computed tomography scans of 52 coyote skulls (28 female, 24 male; 1 day to 13.4 years) and 46 gray wolf skulls (25 female, 21 male; 1 day to 7.9 years). Age was known in coyotes or estimated from dentition patterns in wolves. The 95% asymptotic growth of the endocranium is completed by 21 weeks in male and 17.5 weeks in female coyotes and by 27 weeks in male and 18.5 weeks in female wolves. These ages are well before age at first reproduction (coyote - 40.4 weeks; wolf - 91.25 weeks). Skull growth as measured by centroid size lags behind endocranial growth but is also completed before sexual maturity. Intra- and interspecific comparisons of brain volumes in the adult wolves and coyotes revealed that relative anterior cerebrum (AC) volume was greater in males than females in both species. Relative brain size was greater in the coyote than in the wolf as was relative cerebrum volume. However, relative AC volume and relative cerebellum and brainstem volume was greater in the wolf than coyote. One explanation for the increased AC volume in males compared to females may be related to the role of social information processing. However, additional data are needed to determine the correspondence between regional volumes and functional differences either between or within these species. Nonetheless, these findings provide important baseline data for further studies on wild canid brain variations and development. © 2018 S. Karger AG, Basel.
Analyzing multimodality tomographic images and associated regions of interest with MIDAS
NASA Astrophysics Data System (ADS)
Tsui, Wai-Hon; Rusinek, Henry; Van Gelder, Peter; Lebedev, Sergey
2001-07-01
This paper outlines the design and features incorporated in a software package for analyzing multi-modality tomographic images. The package MIDAS has been evolving for the past 15 years and is in wide use by researchers at New York University School of Medicine and a number of collaborating research sites. It was written in the C language and runs on Sun workstations and Intel PCs under the Solaris operating system. A unique strength of the MIDAS package lies in its ability to generate, manipulate and analyze a practically unlimited number of regions of interest (ROIs). These regions are automatically saved in an efficient data structure and linked to associated images. A wide selection of set theoretical (e.g. union, xor, difference), geometrical (e.g. move, rotate) and morphological (grow, peel) operators can be applied to an arbitrary selection of ROIs. ROIs are constructed as a result of image segmentation algorithms incorporated in MIDAS; they also can be drawn interactively. These ROI editing operations can be applied in either 2D or 3D mode. ROI statistics generated by MIDAS include means, standard deviations, centroids and histograms. Other image manipulation tools incorporated in MIDAS are multimodality and within modality coregistration methods (including landmark matching, surface fitting and Woods' correlation methods) and image reformatting methods (using nearest-neighbor, tri-linear or sinc interpolation). Applications of MIDAS include: (1) neuroanatomy research: marking anatomical structures in one orientation, reformatting marks to another orientation; (2) tissue volume measurements: brain structures (PET, MRI, CT), lung nodules (low dose CT), breast density (MRI); (3) analysis of functional (SPECT, PET) experiments by overlaying corresponding structural scans; (4) longitudinal studies: regional measurement of atrophy.
Clinical applications with the HIDAC positron camera
NASA Astrophysics Data System (ADS)
Frey, P.; Schaller, G.; Christin, A.; Townsend, D.; Tochon-Danguy, H.; Wensveen, M.; Donath, A.
1988-06-01
A high density avalanche chamber (HIDAC) positron camera has been used for positron emission tomographic (PET) imaging in three different human studies, including patients presenting with: (I) thyroid diseases (124 cases); (II) clinically suspected malignant tumours of the pharynx or larynx (ENT) region (23 cases); and (III) clinically suspected primary malignant and metastatic tumours of the liver (9 cases, 19 PET scans). The positron emitting radiopharmaceuticals used for the three studies were Na 124I (4.2 d half-life) for the thyroid, 55Co-bleomycin (17.5 h half-life) for the ENT-region and 68Ga-colloid (68 min half-life) for the liver. Tomographic imaging was performed: (I) 24 h after oral Na 124I administration to the thyroid patients, (II) 18 h after intraveneous administration of 55Co-bleomycin to the ENT patients and (III) 20 min following the intraveneous injection of 68Ga-colloid to the liver tumour patients. Three different imaging protocols were used with the HIDAC positron camera to perform appropriate tomographic imaging in each patient study. Promising results were obtained in all three studies, particularly in tomographic thyroid imaging, where a significant clinical contribution is made possible for diagnosis and therapy planning by the PET technique. In the other two PET studies encouraging results were obtained for the detection and precise localisation of malignant tumour disease including an estimate of the functional liver volume based on the reticulo-endothelial-system (RES) of the liver, obtained in vivo, and the three-dimensional display of liver PET data using shaded graphics techniques. The clinical significance of the overall results obtained in both the ENT and the liver PET study, however, is still uncertain and the respective role of PET as a new imaging modality in these applications is not yet clearly established. To appreciate the clinical impact made by PET in liver and ENT malignant tumour staging needs further investigation, and more detailed data on a larger number of clinical and experimental PET scans will be necessary for definitive evaluation. Nevertheless, the HIDAC positron camera may be used for clinical PET imaging in well-defined patient cases, particularly in situations where both high spatial resolution is desired in the reconstructed image of the examined pathological condition and at the same time "static" PET imaging may be adequate, as is the case in thyroid-, ENT- and liver tomographic imaging using the HIDAC positron camera.
Abu-Judeh, H H; Levine, S; Kumar, M; el-Zeftawy, H; Naddaf, S; Lou, J Q; Abdel-Dayem, H M
1998-11-01
Chronic fatigue syndrome is a clinically defined condition of uncertain aetiology. We compared 99Tcm-HMPAO single photon emission tomography (SPET) brain perfusion with dual-head 18F-FDG brain metabolism in patients with chronic fatigue syndrome. Eighteen patients (14 females, 4 males), who fulfilled the diagnostic criteria of the Centers for Disease Control for chronic fatigue syndrome, were investigated. Thirteen patients had abnormal SPET brain perfusion scans and five had normal scans. Fifteen patients had normal glucose brain metabolism scans and three had abnormal scans. We conclude that, in chronic fatigue syndrome patients, there is discordance between SPET brain perfusion and 18F-FDG brain uptake. It is possible to have brain perfusion abnormalities without corresponding changes in glucose uptake.
Fluorescent scanning x-ray tomography with synchrotron radiation
NASA Astrophysics Data System (ADS)
Takeda, Tohoru; Maeda, Toshikazu; Yuasa, Tetsuya; Akatsuka, Takao; Ito, Tatsuo; Kishi, Kenichi; Wu, Jin; Kazama, Masahiro; Hyodo, Kazuyuki; Itai, Yuji
1995-02-01
Fluorescent scanning (FS) x-ray tomography was developed to detect nonradioactive tracer materials (iodine and gadolinium) in a living object. FS x-ray tomography consists of a silicon (111) channel cut monochromator, an x-ray shutter, an x-ray slit system and a collimator for detection, a scanning table for the target organ, and an x-ray detector with pure germanium. The minimal detectable dose of iodine in this experiment was 100 ng in a volume of 2 mm3 and a linear relationship was shown between the photon counts of a fluorescent x ray and the concentration of iodine contrast material. A FS x-ray tomographic image was clearly obtained with a phantom.
Virtual endoscopic imaging of the spine.
Kotani, Toshiaki; Nagaya, Shigeyuki; Sonoda, Masaru; Akazawa, Tsutomu; Lumawig, Jose Miguel T; Nemoto, Tetsuharu; Koshi, Takana; Kamiya, Koshiro; Hirosawa, Naoya; Minami, Shohei
2012-05-20
Prospective trial of virtual endoscopy in spinal surgery. To investigate the utility of virtual endoscopy of the spine in conjunction with spinal surgery. Several studies have described clinical applications of virtual endoscopy to visualize the inside of the bronchi, paranasal sinus, stomach, small intestine, pancreatic duct, and bile duct, but, to date, no study has described the use of virtual endoscopy in the spine. Virtual endoscopy is a realistic 3-dimensional intraluminal simulation of tubular structures that is generated by postprocessing of computed tomographic data sets. Five patients with spinal disease were selected: 2 patients with degenerative disease, 2 patients with spinal deformity, and 1 patient with spinal injury. Virtual endoscopy software allows an observer to explore the spinal canal with a mouse, using multislice computed tomographic data. Our study found that virtual endoscopy of the spine has advantages compared with standard imaging methods because surgeons can noninvasively explore the spinal canal in all directions. Virtual endoscopy of the spine may be useful to surgeons for diagnosis, preoperative planning, and postoperative assessment by obviating the need to mentally construct a 3-dimensional picture of the spinal canal from 2-dimensional computed tomographic scans.
Soh, Shui-Boon; Pham, Alan; O'Hehir, Robyn E; Cherk, Martin; Topliss, Duncan J
2013-09-01
A 42-year-old woman presented with a rapidly enlarging right-sided thyroid mass and underwent hemithyroidectomy. Riedel's thyroiditis was only diagnosed upon surgical decompression of the right carotid artery 2 years later. She became more symptomatic as Riedel's thyroiditis progressed, and mediastinal fibrosclerosis developed over the next 12 months. Oral prednisolone failed to improve her condition, and she was commenced on tamoxifen. Despite initial improvement, her symptoms recurred 2 years later, mainly arising from compression of the trachea and esophagus at the thoracic inlet. Fluorodeoxyglucose positron emission tomographic scan showed locally advanced active invasive fibrosclerosis in the neck and mediastinum. An elevated activin-A level of 218 pg/mL was consistent with active inflammation. IgG subtypes (including IgG4) were normal. Two courses of iv methylprednisolone were given but only produced transient improvement. Subsequently, the patient received 3 doses of i.v. rituximab at monthly intervals and had prompt sustained symptomatic improvement. Activin-A level decreased to 122 pg/mL 10 months after rituximab therapy. Fluorodeoxyglucose positron emission tomographic scan 6 weeks after therapy showed reduction in inflammation. A further scan at 10 months demonstrated ongoing response to rituximab. This is a case of refractory Riedel's thyroiditis with symptomatic, biochemical, and radiological improvement that has persisted 14 months after rituximab. The likelihood and duration of response to rituximab in Riedel's thyroiditis requires further study.
Planning surgical reconstruction in Treacher-Collins syndrome using virtual simulation.
Nikkhah, Dariush; Ponniah, Allan; Ruff, Cliff; Dunaway, David
2013-11-01
Treacher-Collins syndrome is a rare autosomal dominant condition of varying phenotypic expression. The surgical correction in this syndrome is difficult, and the approach varies between craniofacial departments worldwide. The authors aimed to design standardized tools for planning orbitozygomatic and mandibular reconstruction in Treacher-Collins syndrome using geometric morphometrics. The Great Ormond Street Hospital database was retrospectively identified for patients with Treacher-Collins syndrome. Thirteen children (aged 2 to 15 years) who had suitable preoperative three-dimensional computed tomographic head scans were included. Six Treacher-Collins syndrome three-dimensional computed tomographic head scans were quantitatively compared using a template of 96 anatomically defined landmarks to 26 age-matched normal dry skulls. Thin-plate spline videos illustrated the characteristic deformities of retromicrognathia and maxillary and orbitozygomatic hypoplasia in the Treacher-Collins syndrome population. Geometric morphometrics was used in the virtual reconstruction of the orbitozygomatic and mandibular region in Treacher-Collins syndrome patients. Intrarater and interrater reliability of the landmarks was acceptable and within a standard deviation of less than 1 mm on 97 percent and 100 percent of 10 repeated scans, respectively. Virtual normalization of the Treacher-Collins syndrome skull effectively describes characteristic skeletal deformities and provides a useful guide to surgical reconstruction. Size-matched stereolithographic templates derived from thin-plate spline warps can provide effective intraoperative templates for zygomatic and mandibular reconstruction in the Treacher-Collins syndrome patient. Diagnostic, V.
Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-03-01
We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.
Abdallah, Faraj W; Yu, Eugene; Cholvisudhi, Phantila; Niazi, Ahtsham U; Chin, Ki J; Abbas, Sherif; Chan, Vincent W
2017-01-01
Ultrasound (US) imaging of the airway may be useful in predicting difficulty of airway management (DAM); but its use is limited by lack of proof of its validity and reliability. We sought to validate US imaging of the airway by comparison to CT-scan, and to assess its inter- and intra-observer reliability. We used submandibular sonographic imaging of the mouth and oropharynx to examine how well the ratio of tongue thickness to oral cavity height correlates with the ratio of tongue volume to oral cavity volume, an established tomographic measure of DAM. A cohort of 34 patients undergoing CT-scan was recruited. Study standardized assessments included CT-measured ratios of tongue volume to oropharyngeal cavity volume; tongue thickness to oral cavity height; and US-measured ratio of tongue thickness to oral cavity height. Two sonographers independently performed US imaging of the airway before and after CT-scan. Our findings indicate that the US-measured ratio of tongue thickness to oral cavity height highly correlates with the CT-measured ratio of tongue volume to oral cavity volume. US measurements also demonstrated strong inter- and intra-observer reliability. This study suggests that US is a valid and reliable tool for imaging the oral and oropharyngeal parts of the airway, as well as for measuring the volumetric relationship between the tongue and oral cavity, and may therefore be a useful predictor of DAM. © 2016 by the American Institute of Ultrasound in Medicine.
Vendemia, Nicholas; Chao, Jerry; Ivanidze, Jana; Sanelli, Pina; Spinelli, Henry M
2011-01-01
Medpor (Porex Surgical, Inc, Newnan, GA) is composed of porous polyethylene and is commonly used in craniofacial reconstruction. When complications such as seroma or abscess formation arise, diagnostic modalities are limited because Medpor is radiolucent on conventional radiologic studies. This poses a problem in situations where imaging is necessary to distinguish the implant from surrounding tissues. To present a clinically useful method for imaging Medpor with conventional computed tomographic (CT) scanning. Eleven patients (12 total implants) who have undergone reconstructive surgery with Medpor were included in the study. A retrospective review of CT scans done between 1 and 16 months postoperatively was performed using 3 distinct CT window settings. Measurements of implant dimensions and Hounsfield units were recorded and qualitatively assessed. Of the 3 distinct window settings studied, namely, "bone" (W1100/L450), "soft tissue"; (W500/L50), and "implant" (W800/L200), the implant window proved the most ideal, allowing the investigators to visualize and evaluate Medpor in all cases. Qualitative analysis revealed that Medpor implants were able to be distinguished from surrounding tissue in both the implant and soft tissue windows, with a density falling between that of fat and fluid. In 1 case, Medpor could not be visualized in the soft tissue window, although it could be visualized in the implant window. Quantitative analysis demonstrated a mean (SD) density of -38.7 (7.4) Hounsfield units. Medpor may be optimally visualized on conventional CT scans using the implant window settings W800/L200, which can aid in imaging Medpor and diagnosing implant-related complications.
NASA Astrophysics Data System (ADS)
Kunitsyn, V.; Nesterov, I.; Andreeva, E.; Zelenyi, L.; Veselov, M.; Galperin, Y.; Buchner, J.
A satellite radiotomography method for electron density distributions was recently proposed for closely-space multi-spacecraft group of high-altitude satellites to study the physics of reconnection process. The original idea of the ROY project is to use a constellation of spacecrafts (one main and several sub-satellites) in order to carry out closely-spaced multipoint measurements and 2D tomographic reconstruction of elec- tron density in the space between the main satellite and the subsatellites. The distances between the satellites were chosen to vary from dozens to few hundreds of kilometers. The easiest data interpretation is achieved when the subsatellites are placed along the plasma streamline. Then, whenever a plasma density irregularity moves between the main satellite and the subsatellites it will be scanned in different directions and we can get 2D distribution of plasma using these projections. However in general sub- satellites are not placed exactly along the plasma streamline. The method of plasma velocity determination relative to multi-spacecraft systems is considered. Possibilities of 3D tomographic imaging using multi-spacecraft systems are analyzed. The model- ing has shown that efficient scheme for 3D tomographic imaging would be to place spacecrafts in different planes so that the angle between the planes would make not more then ten degrees. Work is supported by INTAS PROJECT 2000-465.
Initial studies using the RatCAP conscious animal PET tomograph
NASA Astrophysics Data System (ADS)
Woody, C.; Vaska, P.; Schlyer, D.; Pratte, J.-F.; Junnarkar, S.; Park, S.-J.; Stoll, S.; Purschke, M.; Southekal, S.; Kriplani, A.; Krishnamoorthy, S.; Maramraju, S.; Lee, D.; Schiffer, W.; Dewey, S.; Neill, J.; Kandasamy, A.; O'Connor, P.; Radeka, V.; Fontaine, R.; Lecomte, R.
2007-02-01
The RatCAP is a small, head-mounted PET tomograph designed to image the brain of a conscious rat without the use of anesthesia. The detector is a complete, high-performance 3D tomograph consisting of a 3.8 cm inside-diameter ring containing 12 block detectors, each of which is comprised of a 4×8 array of 2.2×2.2×5 mm 3 LSO crystals readout with a matching APD array and custom ASIC, and has a 1.8 cm axial field of view. Construction of the first working prototype detector has been completed and its performance characteristics have been measured. The results show an intrinsic spatial resolution of 2.1 mm, a time resolution of ˜14 ns FWHM, and a sensitivity of 0.7% at an energy threshold of 150 keV. First preliminary images have been obtained using 18F-FDG and 11C-methamphetamine, which show comparable image quality to those obtained from a commercial MicroPET R4 scanner. Initial studies have also been carried out to study stress levels in rats wearing the RatCAP.
NASA Astrophysics Data System (ADS)
Tornai, Martin P.; Bowsher, James E.; Archer, Caryl N.; Peter, Jörg; Jaszczak, Ronald J.; MacDonald, Lawrence R.; Patt, Bradley E.; Iwanczyk, Jan S.
2003-01-01
A novel tomographic gantry was designed, built and initially evaluated for single photon emission imaging of metabolically active lesions in the pendant breast and near chest wall. Initial emission imaging measurements with breast lesions of various uptake ratios are presented. Methods: A prototype tomograph was constructed utilizing a compact gamma camera having a field-of-view of <13×13 cm 2 with arrays of 2×2×6 mm 3 quantized NaI(Tl) scintillators coupled to position sensitive PMTs. The camera was mounted on a radially oriented support with 6 cm variable radius-of-rotation. This unit is further mounted on a goniometric cradle providing polar motion, and in turn mounted on an azimuthal rotation stage capable of indefinite vertical axis-of-rotation about the central rotation axis (RA). Initial measurements with isotopic Tc-99 m (140 keV) to evaluate the system include acquisitions with various polar tilt angles about the RA. Tomographic measurements were made of a frequency and resolution cold-rod phantom filled with aqueous Tc-99 m. Tomographic and planar measurements of 0.6 and 1.0 cm diameter fillable spheres in an available ˜950 ml hemi-ellipsoidal (uncompressed) breast phantom attached to a life-size anthropomorphic torso phantom with lesion:breast-and-body:cardiac-and-liver activity concentration ratios of 11:1:19 were compared. Various photopeak energy windows from 10-30% widths were obtained, along with a 35% scatter window below a 15% photopeak window from the list mode data. Projections with all photopeak window and camera tilt conditions were reconstructed with an ordered subsets expectation maximization (OSEM) algorithm capable of reconstructing arbitrary tomographic orbits. Results: As iteration number increased for the tomographically measured data at all polar angles, contrasts increased while signal-to-noise ratios (SNRs) decreased in the expected way with OSEM reconstruction. The rollover between contrast improvement and SNR degradation of the lesion occurred at two to three iterations. The reconstructed tomographic data yielded SNRs with or without scatter correction that were >9 times better than the planar scans. There was up to a factor of ˜2.5 increase in total primary and scatter contamination in the photopeak window with increasing tilt angle from 15° to 45°, consistent with more direct line-of-sight of myocardial and liver activity with increased camera polar angle. Conclusion: This new, ultra-compact, dedicated tomographic imaging system has the potential of providing valuable, fully 3D functional information about small, otherwise indeterminate breast lesions as an adjunct to diagnostic mammography.
[Non-operation management of 12 cases with brain abscess demonstrated by CT scan].
Long, J
1990-12-01
This paper reported 12 cases with brain abscess demonstrated by CT scan. Using antibiotic management without surgical intervention, in 10 cases the curative effects were satisfactory. The paper indicated that CT scan was very useful in prompt and correct diagnosis of brain abscess and with sequential CT scan medical therapy was feasible. It is significant in treatment of brain abscess especially for the patients who have a poor general condition, have the brain abscess located in important functional area or have multiple abscesses so that the operation is difficult for them.
Synthetic aperture tomographic phase microscopy for 3D imaging of live cells in translational motion
Lue, Niyom; Choi, Wonshik; Popescu, Gabriel; Badizadegan, Kamran; Dasari, Ramachandra R.; Feld, Michael S.
2009-01-01
We present a technique for 3D imaging of live cells in translational motion without need of axial scanning of objective lens. A set of transmitted electric field images of cells at successive points of transverse translation is taken with a focused beam illumination. Based on Hyugens’ principle, angular plane waves are synthesized from E-field images of a focused beam. For a set of synthesized angular plane waves, we apply a filtered back-projection algorithm and obtain 3D maps of refractive index of live cells. This technique, which we refer to as synthetic aperture tomographic phase microscopy, can potentially be combined with flow cytometry or microfluidic devices, and will enable high throughput acquisition of quantitative refractive index data from large numbers of cells. PMID:18825263
NASA Astrophysics Data System (ADS)
Dymond, K.; Nicholas, A. C.; Budzien, S. A.; Stephan, A. W.; Coker, C.; Hei, M. A.; Groves, K. M.
2015-12-01
The Special Sensor Ultraviolet Limb Imager (SSULI) instruments are ultraviolet limb scanning sensors flying on the Defense Meteorological Satellite Program (DMSP) satellites. The SSULIs observe the 80-170 nanometer wavelength range covering emissions at 91 and 136 nm, which are produced by radiative recombination of the ionosphere. We invert these emissions tomographically using newly developed algorithms that include optical depth effects due to pure absorption and resonant scattering. We present the details of our approach including how the optimal altitude and along-track sampling were determined and the newly developed approach we are using for regularizing the SSULI tomographic inversions. Finally, we conclude with validations of the SSULI inversions against ALTAIR incoherent scatter radar measurements and demonstrate excellent agreement between the measurements.
Singular value decomposition for the truncated Hilbert transform
NASA Astrophysics Data System (ADS)
Katsevich, A.
2010-11-01
Starting from a breakthrough result by Gelfand and Graev, inversion of the Hilbert transform became a very important tool for image reconstruction in tomography. In particular, their result is useful when the tomographic data are truncated and one deals with an interior problem. As was established recently, the interior problem admits a stable and unique solution when some a priori information about the object being scanned is available. The most common approach to solving the interior problem is based on converting it to the Hilbert transform and performing analytic continuation. Depending on what type of tomographic data are available, one gets different Hilbert inversion problems. In this paper, we consider two such problems and establish singular value decomposition for the operators involved. We also propose algorithms for performing analytic continuation.
Functional-Lesion Investigation of Developmental Stuttering with Positron Emission Tomography.
ERIC Educational Resources Information Center
Ingham, Roger J.; And Others
1996-01-01
Analysis of use of positron emission tomographic measurements of resting-state regional cerebral blood flow in 29 men, 10 of whom stuttered, did not support the idea that developmental stuttering is associated with abnormalities of blood flow at rest. Findings did suggest an essentially normal functional brain terrain with a small number of minor…
Brain Correlates of Stuttering and Syllable Production: Gender Comparison and Replication.
ERIC Educational Resources Information Center
Ingham, Roger J.; Fox, Peter T.; Ingham, Janis C.; Xiong, Jinhu; Zamarripa, Frank; Hardies, L. Jean; Lancaster, Jack L.
2004-01-01
This article reports a gender replication study of the P. T. Fox et a. (2000) performance correlation analysis of neural systems that distinguish between normal and stuttered speech in adult males. Positron-emission tomographic (PET) images of cerebral blood flow (CBF) were correlated with speech behavior scores obtained during PET imaging for 10…
Concurrent EEG And NIRS Tomographic Imaging Based on Wearable Electro-Optodes
2014-04-13
Interfaces ( BCIs ), and other systems in the same computational framework. Figure 11 below shows...Improving Brain-‐Computer Interfaces Using Independent Component Analysis, In: Towards Future BCIs , 2012
McClure, J T; Browning, R T; Vantrease, C M; Bittle, S T
1994-01-01
Previous research suggests that traumatic brain injury (TBI) results in impairment of iconic memory abilities.We would like to acknowledge the contribution of Jeffrey D. Vantrease, who wrote the software program for the Iconic Memory procedure and measurement. This raises serious implications for brain injury rehabilitation. Most cognitive rehabilitation programs do not include iconic memory training. Instead it is common for cognitive rehabilitation programs to focus on attention and concentration skills, memory skills, and visual scanning skills.This study compared the iconic memory skills of brain-injury survivors and control subjects who all reached criterion levels of visual scanning skills. This involved previous training for the brain-injury survivors using popular visual scanning programs that allowed them to visually scan with response time and accuracy within normal limits. Control subjects required only minimal training to reach normal limits criteria. This comparison allows for the dissociation of visual scanning skills and iconic memory skills.The results are discussed in terms of their implications for cognitive rehabilitation and the relationship between visual scanning training and iconic memory skills.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Potchen, E.J.
Data relating to the determination of the efficacy of radionuclide brain scanning have been analyzed. The data were gathered at a teaching hospital by use of a prospective questionnaire followed by a retrospective study of the result of the brain scan examination. Data analysis was accomplished using a method of pattern discovery which relates selected outcomes such as normal and abnormal brain scans to patient attributes (signs, symptoms, history, and previous test results). The objective of the analysis was the identification of patterns or clusters of patient attributes which have a high probability of acting as predictors of the outcomemore » of the brain scan.« less
ERIC Educational Resources Information Center
Balottin, Umberto; And Others
1989-01-01
The study of computerized tomography brain-scan findings with 45 autistic and 19 control subjects concluded that autism is nonspecifically associated with brain-scan abnormalities, and that other nonorganic, as well as organic, factors should be taken into account. (Author/DB)
Comparison of computed tomography and complex motion tomography in the evaluation of cholesteatoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shaffer, K.A.
1984-08-01
High-resolution axial and coronal computed tomographic (CT) scans were compared with coronal and sagittal complex motion tomograms in patients with suspected middle ear cholesteatomas. Information on CT scans equaled or exceeded that on conventional complex motion tomograms in 16 of 17 patients, and in 11 it provided additional information. Soft-tissue resolution was superior with CT. In 14 patients who underwent surgery, CT provided information that was valuable to the surgeon. On the basis of this study, high-resolution CT is recommended as the preferred method for evaluating most patients with cholesteatomas of the temporal bone.
[Prostatic abscess. Contribution of the x-ray computed tomography. Apropos of a case].
Husain, A; Touzard, D
1988-01-01
We reported a case of prostatic abscess due to staphylococeus aureus developed in a chronic alcoholic patient. The clinical symptoms and signs were largely masked by prior antibiotic therapy. Computed axial tomographic scanning of the pelvis made the diagnosis and demonstrated the resolution of the prostatic abscess following antibiotic therapy and spontaneous rupture to the urethra.
Pseudo tumors of the lung after lung volume reduction surgery.
Oey, Inger F; Jeyapalan, Kanagaratnam; Entwisle, James J; Waller, David A
2004-03-01
We describe 2 patients who underwent lung volume reduction surgery, who postoperatively had computed tomographic scans that showed symptomatic mass lesions suggestive of malignancy and an inhaled foreign body. Investigations excluded these conditions with the remaining likely diagnosis of pseudotumor secondary to buttressing material. These potential sequelae of lung volume reduction surgery should be recognized in follow-up investigations.
Scanning transmission electron microscopy through-focal tilt-series on biological specimens.
Trepout, Sylvain; Messaoudi, Cédric; Perrot, Sylvie; Bastin, Philippe; Marco, Sergio
2015-10-01
Since scanning transmission electron microscopy can produce high signal-to-noise ratio bright-field images of thick (≥500 nm) specimens, this tool is emerging as the method of choice to study thick biological samples via tomographic approaches. However, in a convergent-beam configuration, the depth of field is limited because only a thin portion of the specimen (from a few nanometres to tens of nanometres depending on the convergence angle) can be imaged in focus. A method known as through-focal imaging enables recovery of the full depth of information by combining images acquired at different levels of focus. In this work, we compare tomographic reconstruction with the through-focal tilt-series approach (a multifocal series of images per tilt angle) with reconstruction with the classic tilt-series acquisition scheme (one single-focus image per tilt angle). We visualised the base of the flagellum in the protist Trypanosoma brucei via an acquisition and image-processing method tailored to obtain quantitative and qualitative descriptors of reconstruction volumes. Reconstructions using through-focal imaging contained more contrast and more details for thick (≥500 nm) biological samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Multislice spiral CT simulator for dynamic cardiopulmonary studies
NASA Astrophysics Data System (ADS)
De Francesco, Silvia; Ferreira da Silva, Augusto M.
2002-04-01
We've developed a Multi-slice Spiral CT Simulator modeling the acquisition process of a real tomograph over a 4-dimensional phantom (4D MCAT) of the human thorax. The simulator allows us to visually characterize artifacts due to insufficient temporal sampling and a priori evaluate the quality of the images obtained in cardio-pulmonary studies (both with single-/multi-slice and ECG gated acquisition processes). The simulating environment allows both for conventional and spiral scanning modes and includes a model of noise in the acquisition process. In case of spiral scanning, reconstruction facilities include longitudinal interpolation methods (360LI and 180LI both for single and multi-slice). Then, the reconstruction of the section is performed through FBP. The reconstructed images/volumes are affected by distortion due to insufficient temporal sampling of the moving object. The developed simulating environment allows us to investigate the nature of the distortion characterizing it qualitatively and quantitatively (using, for example, Herman's measures). Much of our work is focused on the determination of adequate temporal sampling and sinogram regularization techniques. At the moment, the simulator model is limited to the case of multi-slice tomograph, being planned as a next step of development the extension to cone beam or area detectors.
Fang, Jing-Jing; Liu, Jia-Kuang; Wu, Tzu-Chieh; Lee, Jing-Wei; Kuo, Tai-Hong
2013-05-01
Computer-aided design has gained increasing popularity in clinical practice, and the advent of rapid prototyping technology has further enhanced the quality and predictability of surgical outcomes. It provides target guides for complex bony reconstruction during surgery. Therefore, surgeons can efficiently and precisely target fracture restorations. Based on three-dimensional models generated from a computed tomographic scan, precise preoperative planning simulation on a computer is possible. Combining the interdisciplinary knowledge of surgeons and engineers, this study proposes a novel surgical guidance method that incorporates a built-in occlusal wafer that serves as the positioning reference.Two patients with complex facial deformity suffering from severe facial asymmetry problems were recruited. In vitro facial reconstruction was first rehearsed on physical models, where a customized surgical guide incorporating a built-in occlusal stent as the positioning reference was designed to implement the surgery plan. This study is intended to present the authors' preliminary experience in a complex facial reconstruction procedure. It suggests that in regions with less information, where intraoperative computed tomographic scans or navigation systems are not available, our approach could be an effective, expedient, straightforward aid to enhance surgical outcome in a complex facial repair.
Han, Miaomiao; Guo, Zhirong; Liu, Haifeng; Li, Qinghua
2018-05-01
Tomographic Gamma Scanning (TGS) is a method used for the nondestructive assay of radioactive wastes. In TGS, the actual irregular edge voxels are regarded as regular cubic voxels in the traditional treatment method. In this study, in order to improve the performance of TGS, a novel edge treatment method is proposed that considers the actual shapes of these voxels. The two different edge voxel treatment methods were compared by computing the pixel-level relative errors and normalized mean square errors (NMSEs) between the reconstructed transmission images and the ideal images. Both methods were coupled with two different interative algorithms comprising Algebraic Reconstruction Technique (ART) with a non-negativity constraint and Maximum Likelihood Expectation Maximization (MLEM). The results demonstrated that the traditional method for edge voxel treatment can introduce significant error and that the real irregular edge voxel treatment method can improve the performance of TGS by obtaining better transmission reconstruction images. With the real irregular edge voxel treatment method, MLEM algorithm and ART algorithm can be comparable when assaying homogenous matrices, but MLEM algorithm is superior to ART algorithm when assaying heterogeneous matrices. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lemieux, Louis
2001-07-01
A new fully automatic algorithm for the segmentation of the brain and cerebro-spinal fluid (CSF) from T1-weighted volume MRI scans of the head was specifically developed in the context of serial intra-cranial volumetry. The method is an extension of a previously published brain extraction algorithm. The brain mask is used as a basis for CSF segmentation based on morphological operations, automatic histogram analysis and thresholding. Brain segmentation is then obtained by iterative tracking of the brain-CSF interface. Grey matter (GM), white matter (WM) and CSF volumes are calculated based on a model of intensity probability distribution that includes partial volume effects. Accuracy was assessed using a digital phantom scan. Reproducibility was assessed by segmenting pairs of scans from 20 normal subjects scanned 8 months apart and 11 patients with epilepsy scanned 3.5 years apart. Segmentation accuracy as measured by overlap was 98% for the brain and 96% for the intra-cranial tissues. The volume errors were: total brain (TBV): -1.0%, intra-cranial (ICV):0.1%, CSF: +4.8%. For repeated scans, matching resulted in improved reproducibility. In the controls, the coefficient of reliability (CR) was 1.5% for the TVB and 1.0% for the ICV. In the patients, the Cr for the ICV was 1.2%.
Value of brain scanning in the management of strokes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Antunes, J.L.; Schlesinger, E.B.; Michelsen, W.J.
1975-01-01
The usefulness of brain scanning in the diagnosis and management of strokes was evaluated in 313 serial cases. Of 38 patients with transient ischemic attacks (TIAs), only one had a positive test. The optimal time for scanning completed strokes was between seven and 14 days after onset. The pattern of uptake was characteristic of a vascular lesion in 76.8 percent. When uptake was indistinguishable from tumor, follow-up scans were useful. Patients with negative scans in the second week have a significantly better prognosis than the ones with a positive study. Cerebral angiography and brain scan correlated well in 56 patientsmore » who had both tests performed. The postmortem findings in 12 cases again emphasize the importance of the correct timing of the study, and the fact that a brain scan does not usually demonstrate lesions smaller than 2 cm in diameter. It is concluded that the brain scan represents a useful tool in the diagnosis of strokes and helps in predicting the degree of recovery following a vascular insult.« less
Nishiyama, Yuichi; Kanayama, Hidekazu; Mori, Hiroshi; Tada, Keiji; Yamamoto, Yasushi; Katsube, Takashi; Takeshita, Haruo; Kawakami, Kazunori; Kitagaki, Hajime
2017-06-01
This study examined the usefulness of statistical parametric mapping (SPM) for investigating postmortem changes on brain computed tomography (CT). This retrospective study included 128 patients (23 - 100 years old) without cerebral abnormalities who underwent unenhanced brain CT before and after death. The antemortem CT (AMCT) scans and postmortem CT (PMCT) scans were spatially normalized using our original brain CT template, and postmortem changes of CT values (in Hounsfield units; HU) were analysed by the SPM technique. Compared with AMCT scans, 58.6 % and 98.4 % of PMCT scans showed loss of the cerebral sulci and an unclear grey matter (GM)-white matter (WM) interface, respectively. SPM analysis revealed a significant decrease in cortical GM density within 70 min after death on PMCT scans, suggesting cytotoxic brain oedema. Furthermore, there was a significant increase in the density of the WM, lenticular nucleus and thalamus more than 120 min after death. The SPM technique demonstrated typical postmortem changes on brain CT scans, and revealed that the unclear GM-WM interface on early PMCT scans is caused by a rapid decrease in cortical GM density combined with a delayed increase in WM density. SPM may be useful for assessment of whole brain postmortem changes. • The original brain CT template achieved successful normalization of brain morphology. • Postmortem changes in the brain were independent of sex. • Cortical GM density decreased rapidly after death. • WM and deep GM densities increased following cortical GM density change. • SPM could be useful for assessment of whole brain postmortem changes.
Li, Qiao; Gao, Xinyi; Yao, Zhenwei; Feng, Xiaoyuan; He, Huijin; Xue, Jing; Gao, Peiyi; Yang, Lumeng; Cheng, Xin; Chen, Weijian; Yang, Yunjun
2017-09-01
Permeability surface (PS) on computed tomographic perfusion reflects blood-brain barrier permeability and is related to hemorrhagic transformation (HT). HT of deep middle cerebral artery (MCA) territory can occur after recanalization of proximal large-vessel occlusion. We aimed to determine the relationship between HT and PS of deep MCA territory. We retrospectively reviewed 70 consecutive acute ischemic stroke patients presenting with occlusion of the distal internal carotid artery or M1 segment of the MCA. All patients underwent computed tomographic perfusion within 6 hours after symptom onset. Computed tomographic perfusion data were postprocessed to generate maps of different perfusion parameters. Risk factors were identified for increased deep MCA territory PS. Receiver operating characteristic curve analysis was performed to calculate the optimal PS threshold to predict HT of deep MCA territory. Increased PS was associated with HT of deep MCA territory. After adjustments for age, sex, onset time to computed tomographic perfusion, and baseline National Institutes of Health Stroke Scale, poor collateral status (odds ratio, 7.8; 95% confidence interval, 1.67-37.14; P =0.009) and proximal MCA-M1 occlusion (odds ratio, 4.12; 95% confidence interval, 1.03-16.52; P =0.045) were independently associated with increased deep MCA territory PS. Relative PS most accurately predicted HT of deep MCA territory (area under curve, 0.94; optimal threshold, 2.89). Increased PS can predict HT of deep MCA territory after recanalization therapy for cerebral proximal large-vessel occlusion. Proximal MCA-M1 complete occlusion and distal internal carotid artery occlusion in conjunction with poor collaterals elevate deep MCA territory PS. © 2017 American Heart Association, Inc.
Management of focal-onset seizures: an update on drug treatment.
Johannessen, Svein I; Ben-Menachem, Elinor
2006-01-01
Focal-onset seizures are manifestations of abnormal epileptic firing of brain cells in a localised area or areas of the brain. The diagnosis of focal-onset seizures initially entails an EEG, a detailed history from the patient and eyewitnesses, as well as computer tomographic or, preferably, magnetic resonance imaging scans. Video EEG to record ictal events may be necessary to establish the correct diagnosis. Focal seizures are classified according to the International Classification of Epileptic Seizures and International Classification of Epilepsies and Epilepsy Syndromes. It is important to try to decide how the seizure event fits into this system in order to successfully evaluate and optimise treatment, as well as to give detailed information to the patient about their seizures and prognosis. Once the decision to treat the seizures has been made, the physician must choose which medication is the most appropriate to begin with. Carbamazepine, phenytoin or valproic acid (sodium valproate) are often rated as first-line drugs, but factors such as adverse-effect profiles, age, possibility of pregnancy, and concomitant diseases and medication also need to be considered. Most of the newer antiepileptic drugs (AEDs) appear to have good efficacy and better tolerability than the older agents, but evidence to support their superiority is scarce and has led to conflicting advice in several guidelines. Among the newer AEDs, lamotrigine, gabapentin, topiramate and oxcarbazepine have obtained monotherapy indication in many countries. The higher costs of the newer AEDs may inhibit their wider use, especially in poorer countries.
Spectroscopic AC Susceptibility Imaging (sASI) of Magnetic Nanoparticles
Ficko, Bradley W.; Nadar, Priyanka M.; Diamond, Solomon G.
2014-01-01
This study demonstrates a method for alternating current (AC) susceptibility imaging (ASI) of magnetic nanoparticles (mNPs) using low cost instrumentation. The ASI method uses AC magnetic susceptibility measurement to create tomographic images using an array of drive coils, compensation coils and fluxgate magnetometers. Using a spectroscopic approach in conjunction with ASI, a series of tomographic images can be created for each frequency measurement and is termed sASI. The advantage of sASI is that mNPs can be simultaneously characterized and imaged in a biological medium. System calibration was performed by fitting the in-phase and out-of-phase susceptibility measurements of an mNP sample with a hydrodynamic diameter of 100 nm to a Brownian relaxation model (R2 = 0.96). Samples of mNPs with core diameters of 10 and 40 nm and a sample of 100 nm hydrodynamic diameter were prepared in 0.5 ml tubes. Three mNP samples were arranged in a randomized array and then scanned using sASI with six frequencies between 425 and 925 Hz. The sASI scans showed the location and quantity of the mNP samples (R2 = 0.97). Biological compatibility of the sASI method was demonstrated by scanning mNPs that were injected into a pork sausage. The mNP response in the biological medium was found to correlate with a calibration sample (R2 = 0.97, p <0.001). These results demonstrate the concept of ASI and advantages of sASI. PMID:25477704
Marion, D W; Bouma, G J
1991-12-01
Previous studies using the xenon-133 cerebral blood flow (CBF) method have documented the impairment of CO2 vasoresponsivity after a severe head injury, but only global values can be obtained reliably with this technique. We studied CO2 vasoresponsivity using the stable xenon-enhanced computed tomographic CBF method, which provided information about well-defined cortical regions and deep brain structures not available with the xenon-133 method. In 17 patients with admission Glasgow Coma Scale scores of 8 or less, hemispheric CO2 vasoresponsivity ranged from 1.3 to 8.5% per mm Hg change in partial CO2 pressure. Lobar, cerebellar, basal ganglia, and brain stem CO2 vasoresponsivity frequently varied from the mean global value by more than 25%. In all but one patient, local CO2 vasoresponsivity in one or more of these areas differed from the mean global value by more than 50%. The greatest variability occurred in patients with acute subdural hematomas and diffuse (bihemispheric) injuries. This variability in CO2 vasoresponsivity has important implications for the effective and safe management of intracranial hypertension that frequently accompanies severe head injury.
Regional brain hematocrit in stroke by single photon emission computed tomography imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loutfi, I.; Frackowiak, R.S.; Myers, M.J.
1987-01-01
Nineteen studies on 18 subjects were performed by single photon emission computed tomography (SPECT) of the head after the successive intravenous administration of a plasma label (/sup 99m/Tc-human serum albumin (HSA)) and /sup 99m/Tc-labeled autologous red blood cells (RBC). Two sets of cerebral tomographic sections were generated: for cerebral /sup 99m/Tc-HSA alone and for combined /sup 99m/Tc-HSA and /sup 99m/Tc-RBC. By relating counts in regions of interest from the cerebral tomograms to counts from blood samples obtained during each tomographic acquisition, regional cerebral haematocrit (Hct) was calculated by the application of a simple formula. Results show 1) lower cerebral Hctmore » than venous Hct (ratio of HCT brain/Hct venous 0.65-0.90) in all subjects, and 2) comparison between right and left hemisphere Hct in 3/3 normal subjects, 6/6 patients with transient ischaemic attacks and 3/8 patients with stroke showed no significant difference. However, in 3/8 patients with stroke (most recent strokes) significant differences were found, the higher Hct value corresponding to the affected side.« less
Wasyluk, Jaromir T.; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-01-01
Summary Background We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Material/Methods Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. Results The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in μm) differ significantly between GDx and all OCT devices. Conclusions Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients. PMID:22367131
Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David
2012-04-01
Verticalization of the P-wave axis is characteristic of chronic obstructive pulmonary disease (COPD). We studied the correlation of P-wave axis and computerized tomographically quantified emphysema in patients with COPD/emphysema. Individual correlation of P-wave axis with different structural types of emphysema was also studied. High-resolution computerized tomographic scans of 23 patients >45 years old with known COPD were reviewed to assess the type and extent of emphysema using computerized tomographic densitometric parameters. Electrocardiograms were then independently reviewed and the P-wave axis was calculated in customary fashion. Degree of the P vector (DOPV) and radiographic percent emphysematous area (RPEA) were compared for statistical correlation. The P vector and RPEA were also directly compared to the forced expiratory volume at 1 second. RPEA and the P vector had a significant positive correlation in all patients (r = +0.77, p <0.0001) but correlation was very strong in patients with predominant lower lobe emphysema (r = +0.89, p <0.001). Forced expiratory volume at 1 second and the P vector had almost a linear inverse correlation in predominantly lower lobe emphysema (r = -0.92, p <0.001). DOPV positively correlated with radiographically quantified emphysema. DOPV and RPEA were strong predictors of qualitative lung function in patients with predominantly lower lobe emphysema. In conclusion, a combination of high DOPV and predominantly lower lobe emphysema indicates severe obstructive lung dysfunction in patients with COPD. Copyright © 2012 Elsevier Inc. All rights reserved.
Does hydration status affect MRI measures of brain volume or water content?
Meyers, Sandra M; Tam, Roger; Lee, Jimmy S; Kolind, Shannon H; Vavasour, Irene M; Mackie, Emilie; Zhao, Yinshan; Laule, Cornelia; Mädler, Burkhard; Li, David K B; MacKay, Alex L; Traboulsee, Anthony L
2016-08-01
To determine whether differences in hydration state, which could arise from routine clinical procedures such as overnight fasting, affect brain total water content (TWC) and brain volume measured with magnetic resonance imaging (MRI). Twenty healthy volunteers were scanned with a 3T MR scanner four times: day 1, baseline scan; day 2, hydrated scan after consuming 3L of water over 12 hours; day 3, dehydrated scan after overnight fasting of 9 hours, followed by another scan 1 hour later for reproducibility. The following MRI data were collected: T2 relaxation (for TWC measurement), inversion recovery (for T1 measurement), and 3D T1 -weighted (for brain volumes). Body weight and urine specific gravity were also measured. TWC was calculated by fitting the T2 relaxation data with a nonnegative least-squares algorithm, with corrections for T1 relaxation and image signal inhomogeneity and normalization to ventricular cerebrospinal fluid. Brain volume changes were measured using SIENA. TWC means were calculated within 14 tissue regions. Despite indications of dehydration as demonstrated by increases in urine specific gravity (P = 0.03) and decreases in body weight (P = 0.001) between hydrated and dehydrated scans, there was no measurable change in TWC (within any brain region) or brain volume between hydration states. We demonstrate that within a range of physiologic conditions commonly encountered in routine clinical scans (no pretreatment with hydration, well hydrated before MRI, and overnight fasting), brain TWC and brain volumes are not substantially affected in a healthy control cohort. J. Magn. Reson. Imaging 2016;44:296-304. © 2016 Wiley Periodicals, Inc.
DOE R&D Accomplishments Database
Hansche, B. D.
1983-01-01
Computed tomography (CT) is a relatively new radiographic technique which has become widely used in the medical field, where it is better known as computerized axial tomographic (CAT) scanning. This technique is also being adopted by the industrial radiographic community, although the greater range of densities, variation in samples sizes, plus possible requirement for finer resolution make it difficult to duplicate the excellent results that the medical scanners have achieved.
Hendel, Michael D; Bryan, Jason A; Barsoum, Wael K; Rodriguez, Eric J; Brems, John J; Evans, Peter J; Iannotti, Joseph P
2012-12-05
Glenoid component malposition for anatomic shoulder replacement may result in complications. The purpose of this study was to define the efficacy of a new surgical method to place the glenoid component. Thirty-one patients were randomized for glenoid component placement with use of either novel three-dimensional computed tomographic scan planning software combined with patient-specific instrumentation (the glenoid positioning system group), or conventional computed tomographic scan, preoperative planning, and surgical technique, utilizing instruments provided by the implant manufacturer (the standard surgical group). The desired position of the component was determined preoperatively. Postoperatively, a computed tomographic scan was used to define and compare the actual implant location with the preoperative plan. In the standard surgical group, the average preoperative glenoid retroversion was -11.3° (range, -39° to 17°). In the glenoid positioning system group, the average glenoid retroversion was -14.8° (range, -27° to 7°). When the standard surgical group was compared with the glenoid positioning system group, patient-specific instrumentation technology significantly decreased (p < 0.05) the average deviation of implant position for inclination and medial-lateral offset. Overall, the average deviation in version was 6.9° in the standard surgical group and 4.3° in the glenoid positioning system group. The average deviation in inclination was 11.6° in the standard surgical group and 2.9° in the glenoid positioning system group. The greatest benefit of patient-specific instrumentation was observed in patients with retroversion in excess of 16°; the average deviation was 10° in the standard surgical group and 1.2° in the glenoid positioning system group (p < 0.001). Preoperative planning and patient-specific instrumentation use resulted in a significant improvement in the selection and use of the optimal type of implant and a significant reduction in the frequency of malpositioned glenoid implants. Novel three-dimensional preoperative planning, coupled with patient and implant-specific instrumentation, allows the surgeon to better define the preoperative pathology, select the optimal implant design and location, and then accurately execute the plan at the time of surgery.
The ventricles of the brain in the N. American mink (Mustela vison (Brisson, 1756)).
Gościcka, D; Stankiewicz, W; Szpinda, M
1993-01-01
Using anatomical as well as radiographic and tomographic methods, sixty brains of the N. American mink were examined. It was found that the brain consists of four ventricles. Also, it was noted that the posterior horn was missing and that there was the olfactory recess present in the lateral ventricle, a large-size interthalamic connection present in the third ventricle, and a flat, necklace-like bottom in the fourth ventricle. Only recently, the ins and outs of the mink's anatomical structure have begun to absorb anatomists. Apparently, it is related to the fact that furry animals, among them the mink, are being domesticated as if "before our eyes". For this reason and because of the easy access to material, examining of the brain ventricles in the mink was taken up.
Kempen, Paul J; Kircher, Moritz F; de la Zerda, Adam; Zavaleta, Cristina L; Jokerst, Jesse V; Mellinghoff, Ingo K; Gambhir, Sanjiv S; Sinclair, Robert
2015-01-01
The growing use of nanoparticles in biomedical applications, including cancer diagnosis and treatment, demands the capability to exactly locate them within complex biological systems. In this work a correlative optical and scanning electron microscopy technique was developed to locate and observe multi-modal gold core nanoparticle accumulation in brain tumor models. Entire brain sections from mice containing orthotopic brain tumors injected intravenously with nanoparticles were imaged using both optical microscopy to identify the brain tumor, and scanning electron microscopy to identify the individual nanoparticles. Gold-based nanoparticles were readily identified in the scanning electron microscope using backscattered electron imaging as bright spots against a darker background. This information was then correlated to determine the exact location of the nanoparticles within the brain tissue. The nanoparticles were located only in areas that contained tumor cells, and not in the surrounding healthy brain tissue. This correlative technique provides a powerful method to relate the macro- and micro-scale features visible in light microscopy with the nanoscale features resolvable in scanning electron microscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chervenak, Ann L; van Erp, Theo G M; Kesselman, Carl; D'Arcy, Mike; Sobell, Janet; Keator, David; Dahm, Lisa; Murry, Jim; Law, Meng; Hasso, Anton; Ames, Joseph; Macciardi, Fabio; Potkin, Steven G
2012-01-01
Progress in our understanding of brain disorders increasingly relies on the costly collection of large standardized brain magnetic resonance imaging (MRI) data sets. Moreover, the clinical interpretation of brain scans benefits from compare and contrast analyses of scans from patients with similar, and sometimes rare, demographic, diagnostic, and treatment status. A solution to both needs is to acquire standardized, research-ready clinical brain scans and to build the information technology infrastructure to share such scans, along with other pertinent information, across hospitals. This paper describes the design, deployment, and operation of a federated imaging system that captures and shares standardized, de-identified clinical brain images in a federation across multiple institutions. In addition to describing innovative aspects of the system architecture and our initial testing of the deployed infrastructure, we also describe the Standardized Imaging Protocol (SIP) developed for the project and our interactions with the Institutional Review Board (IRB) regarding handling patient data in the federated environment.
Chervenak, Ann L.; van Erp, Theo G.M.; Kesselman, Carl; D’Arcy, Mike; Sobell, Janet; Keator, David; Dahm, Lisa; Murry, Jim; Law, Meng; Hasso, Anton; Ames, Joseph; Macciardi, Fabio; Potkin, Steven G.
2015-01-01
Progress in our understanding of brain disorders increasingly relies on the costly collection of large standardized brain magnetic resonance imaging (MRI) data sets. Moreover, the clinical interpretation of brain scans benefits from compare and contrast analyses of scans from patients with similar, and sometimes rare, demographic, diagnostic, and treatment status. A solution to both needs is to acquire standardized, research-ready clinical brain scans and to build the information technology infrastructure to share such scans, along with other pertinent information, across hospitals. This paper describes the design, deployment, and operation of a federated imaging system that captures and shares standardized, de-identified clinical brain images in a federation across multiple institutions. In addition to describing innovative aspects of the system architecture and our initial testing of the deployed infrastructure, we also describe the Standardized Imaging Protocol (SIP) developed for the project and our interactions with the Institutional Review Board (IRB) regarding handling patient data in the federated environment. PMID:22941984
Reich, H; Moens, Y; Braun, C; Kneissl, S; Noreikat, K; Reske, A
2014-12-01
Quantitative computer tomographic analysis (qCTA) is an accurate but time intensive method used to quantify volume, mass and aeration of the lungs. The aim of this study was to validate a time efficient interpolation technique for application of qCTA in ponies. Forty-one thoracic computer tomographic (CT) scans obtained from eight anaesthetised ponies positioned in dorsal recumbency were included. Total lung volume and mass and their distribution into four compartments (non-aerated, poorly aerated, normally aerated and hyperaerated; defined based on the attenuation in Hounsfield Units) were determined for the entire lung from all 5 mm thick CT-images, 59 (55-66) per animal. An interpolation technique validated for use in humans was then applied to calculate qCTA results for lung volumes and masses from only 10, 12, and 14 selected CT-images per scan. The time required for both procedures was recorded. Results were compared statistically using the Bland-Altman approach. The bias ± 2 SD for total lung volume calculated from interpolation of 10, 12, and 14 CT-images was -1.2 ± 5.8%, 0.1 ± 3.5%, and 0.0 ± 2.5%, respectively. The corresponding results for total lung mass were -1.1 ± 5.9%, 0.0 ± 3.5%, and 0.0 ± 3.0%. The average time for analysis of one thoracic CT-scan using the interpolation method was 1.5-2 h compared to 8 h for analysis of all images of one complete thoracic CT-scan. The calculation of pulmonary qCTA data by interpolation from 12 CT-images was applicable for equine lung CT-scans and reduced the time required for analysis by 75%. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuhl, D.E.; Phelps, M.E.; Engel, J. Jr.
1980-01-01
The ECAT Positron Tomograph was used to scan normal control subjects, stroke patients at various times during recovery, and patients with partial epilepsy during EEG monitoring. /sup 18/F-fluorodeoxyglucose (/sup 18/FDG) and /sup 13/N-Ammonia (/sup 13/NH/sub 3/) were used as indicators of abnormalities in local cerebral glucose utilization (LCMR/sub glc/) and relative perfusion, respectively. Hypometabolism, due to deactivation or minimal damage, was demonstrated with the /sup 18/FDG scan in deep structures and broad zones of cerebral cortex which appeared normal on x-ray CT (XCT) and /sup 99m/Tc pertechnetate scans. In patients with partial epilepsy, who had unilateral or focal electrical abnormalities,more » interictal /sup 18/FDG scan patterns clearly showed localized regions of decreased (20 to 50%) LCMR/sub glc/, which correlated anatomically with the eventual EEG localization.« less
Verbal fluency and positron emission tomographic mapping of regional cerebral glucose metabolism.
Boivin, M J; Giordani, B; Berent, S; Amato, D A; Lehtinen, S; Koeppe, R A; Buchtel, H A; Foster, N L; Kuhl, D E
1992-06-01
Impairment in verbal fluency (VF) has been a consistently reported clinical feature of focal cerebral deficits in frontal and temporal regions. More recent behavioral activation studies with healthy control subjects using positron emission tomography (PET), however, have noted a negative correlation between performance on verbal fluency tasks and regional cortical activity. To see if this negative relationship extends to steady-state non-activation PET measures, thirty-three healthy adults were given a VF task within a day of their 18F-2-fluoro-2-deoxy-D-glucose PET scan. VF was found to correlate positively with left temporal cortical region metabolic activity but to correlate negatively with right and left frontal activity. VF was not correlated significantly with right temporal cortical metabolic activity. Some previous studies with normals using behavioral activation paradigms and PET have reported negative correlations between metabolic activity and cognitive performance similar to that reported here. An explanation for the disparate relationships that were observed between frontal and temporal brain areas and VF might be found in the mediation of different task demands by these separate locations, i.e., task planning and/or initiation by frontal regions and verbal memory by the left temporal area.
Estimation of bias and variance of measurements made from tomography scans
NASA Astrophysics Data System (ADS)
Bradley, Robert S.
2016-09-01
Tomographic imaging modalities are being increasingly used to quantify internal characteristics of objects for a wide range of applications, from medical imaging to materials science research. However, such measurements are typically presented without an assessment being made of their associated variance or confidence interval. In particular, noise in raw scan data places a fundamental lower limit on the variance and bias of measurements made on the reconstructed 3D volumes. In this paper, the simulation-extrapolation technique, which was originally developed for statistical regression, is adapted to estimate the bias and variance for measurements made from a single scan. The application to x-ray tomography is considered in detail and it is demonstrated that the technique can also allow the robustness of automatic segmentation strategies to be compared.
Rapidly Progressive Maxillary Atelectasis.
Elkhatib, Ahmad; McMullen, Kyle; Hachem, Ralph Abi; Carrau, Ricardo L; Mastros, Nicholas
2017-07-01
Report of a patient with rapidly progressive maxillary atelectasis documented by sequential imaging. A 51-year-old man, presented with left periorbital and retro-orbital pain associated with left nasal obstruction. An initial computed tomographic (CT) scan of the paranasal sinuses failed to reveal any significant abnormality. A subsequent CT scan, indicated for recurrence of symptoms 11 months later, showed significant maxillary atelectasis. An uncinectomy, maxillary antrostomy, and anterior ethmoidectomy resulted in a complete resolution of the symptoms. Chronic maxillary atelectasis is most commonly a consequence of chronic rhinosinusitis. All previous reports have indicated a chronic process but lacked documentation of the course of the disease. This report documents a patient of rapidly progressive chronic maxillary atelectasis with CT scans that demonstrate changes in the maxillary sinus (from normal to atelectatic) within 11 months.
NASA Astrophysics Data System (ADS)
Schroer, Christian G.; Seyrich, Martin; Kahnt, Maik; Botta, Stephan; Döhrmann, Ralph; Falkenberg, Gerald; Garrevoet, Jan; Lyubomirskiy, Mikhail; Scholz, Maria; Schropp, Andreas; Wittwer, Felix
2017-09-01
In recent years, ptychography has revolutionized x-ray microscopy in that it is able to overcome the diffraction limit of x-ray optics, pushing the spatial resolution limit down to a few nanometers. However, due to the weak interaction of x rays with matter, the detection of small features inside a sample requires a high coherent fluence on the sample, a high degree of mechanical stability, and a low background signal from the x-ray microscope. The x-ray scanning microscope PtyNAMi at PETRA III is designed for high-spatial-resolution 3D imaging with high sensitivity. The design concept is presented with a special focus on real-time metrology of the sample position during tomographic scanning microscopy.
Malignant external otitis: the role of computed tomography and radionuclides in evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendelson, D.S.; Som, P.M.; Mendelson, M.H.
1983-12-01
Nine patients with malignant external otitis (MEO) were evaluated with Tc-99m bone scans, Ga-67 citrate scans, pluridirectional tomography, and computed tomographic (CT) scans in order to assess the role of each in the diagnosis and management of MEO. The Tc-99m and Ga-67 citrate scans were the most accurate studies in the initial identification of disease activity, while the return to normal or improvement of the Ga-67 citrate scan has been shown to correlate best with clinical resolution of MEO. CT demonstrated soft-tissue disease and central skull base osteomyelitis better than pluridirectional tomography. CT is excellent for localizing and following themore » progression of bone disease; however, because reossification of the skull base is a very slow process, CT cannot be used to follow accurately regression or inactivity of MEO affecting this area. CT is the best modality for following soft-tissue extension of MEO.« less
Childhood CT scans linked to leukemia and brain cancer later in life
Children and young adults scanned multiple times by computed tomography (CT), a commonly used diagnostic tool, have a small increased risk of leukemia and brain tumors in the decade following their first scan.
Cardiac metastases of Ewing sarcoma detected by 18F-FDG PET/CT.
Coccia, Paola; Ruggiero, Antonio; Rufini, Vittoria; Maurizi, Palma; Attinà, Giorgio; Marano, Riccardo; Natale, Luigi; Leccisotti, Lucia; Calcagni, Maria L; Riccardi, Riccardo
2012-04-01
Positron emission tomography (PET) is widely used in the diagnostic evaluation and staging of different malignant tumors. The role of PET/computed tomographic scan in detecting distant metastases in the workup of Ewing sarcoma in children or young adults is less well defined. We report a case of a boy affected by a metastatic Ewing sarcoma with cardiac asymptomatic metastasis detected by F-FDG PET/computed tomography.
Brucella pelvic tubo-ovarian abscess mimicking a pelvic malignancy.
Seoud, Muhiedine A F; Kanj, Suha S; Habli, Munira; Araj, George F; Khalil, Ali M
2003-01-01
A 57-y-old woman presented with recurrent abdominal and pelvic pain of 6 months' duration with low-grade fever. A computed tomographic scan indicated an ovarian tumor. Laparotomy revealed a pelvic abscess. Her symptoms resolved following surgery and antibiotic therapy. Pathology revealed an extensive inflammatory process. Tissue culture grew Brucella sp. The diagnosis and management of this previously undescribed pelvic tubo-ovarian abscess present a particular challenge.
Plenoptic projection fluorescence tomography.
Iglesias, Ignacio; Ripoll, Jorge
2014-09-22
A new method to obtain the three-dimensional localization of fluorochrome distributions in micrometric samples is presented. It uses a microlens array coupled to the image port of a standard microscope to obtain tomographic data by a filtered back-projection algorithm. Scanning of the microlens array is proposed to obtain a dense data set for reconstruction. Simulation and experimental results are shown and the implications of this approach in fast 3D imaging are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Segal-Peretz, Tamar; Zhou, Chun; Ren, Jiaxing
The three-dimensional assembly of poly (styrene-b-methyl methacrylate) (PS-b-PMMA) in chemoepitaxy and graphoepitaxy directed self-assembly (DSA) was investigated using scanning transmission electron microscopy (STEM) tomography. The tomographic characterization revealed hidden morphologies and defects at the BCP- chemical pattern interface in lamellar DSA, and probed the formation of cylinders at the bottom of cylindrical DSA for contact hole shrink. Lastly, future work will include control over 3D assembly in sub-10 nm processes.
Computed tomographic findings in 44 dogs and 10 cats with grass seed foreign bodies.
Vansteenkiste, D P; Lee, K C L; Lamb, C R
2014-11-01
To supplement recent reports of computed tomographic (CT) findings in dogs and cats with grass seed foreign bodies. Retrospective review of cases that had CT scan and subsequent retrieval of a grass seed during the same period of hospitalisation from a site included in the scan. Records of 44 dogs and 10 cats were reviewed. Most were presented in the months July to December. Median duration of clinical signs was 4 weeks (range 2 days to 2 years). The most frequent clinical signs were soft tissue swelling (30% cases), coughing (28%), sneezing (28%) and discharge (26%). Grass seeds were retrieved from the thorax (35% cases), nasal cavity (31%), ear (7%), other sites in the head and neck (22%), sublumbar muscles (2%) and pelvic limb (2%). The grass seed was visible in CT images in 10 (19%) cases. Secondary lesions were visible in CT images of 52 (96%) cases, including collection of exudate (37%), abscess (24%), enlarged lymph nodes (22%) and pulmonary consolidation (20%). CT images appeared normal in 4% animals. Grass seeds within the respiratory tract are frequently visible in CT images, but in general CT appears to be more useful for localisation of secondary lesions than as a method of definite diagnosis. © 2014 British Small Animal Veterinary Association.
NASA Astrophysics Data System (ADS)
Olaguer, Eduardo P.; Stutz, Jochen; Erickson, Matthew H.; Hurlock, Stephen C.; Cheung, Ross; Tsai, Catalina; Colosimo, Santo F.; Festa, James; Wijesinghe, Asanga; Neish, Bradley S.
2017-02-01
During the Benzene and other Toxics Exposure (BEE-TEX) study, a remote sensing network based on long path Differential Optical Absorption Spectroscopy (DOAS) was set up in the Manchester neighborhood beside the Ship Channel of Houston, Texas in order to perform Computer Aided Tomography (CAT) scans of hazardous air pollutants. On 18-19 February 2015, the CAT scan network detected large nocturnal plumes of toluene and xylenes most likely associated with railcar loading and unloading operations at Ship Channel petrochemical facilities. The presence of such plumes during railcar operations was confirmed by a mobile laboratory equipped with a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), which measured transient peaks of toluene and C2-benzenes of 50 ppb and 57 ppb respectively around 4 a.m. LST on 19 February 2015. Plume reconstruction and source attribution were performed using the 4D variational data assimilation technique and a 3D micro-scale forward and adjoint air quality model based on both tomographic and PTR-MS data. Inverse model estimates of fugitive emissions associated with railcar transfer emissions ranged from 2.0 to 8.2 kg/hr for toluene and from 2.2 to 3.5 kg/hr for xylenes in the early morning of 19 February 2015.
Microendoscopic excision of C2 osteoid osteoma: a technical report.
Kulkarni, Arvind G; Dhruv, Abhilash N; Bassi, Anupreet J
2013-09-01
Case report and description of technique. To describe a microendoscopic posterior approach for excision of an osteoid osteoma of C2. Microendoscopic techniques are widely used in the management of degenerative disorders of the spine. This is the first report of their use in the management of an osteoid osteoma via the posterior approach. A 12-year-old-boy presented with left-sided neck pain of 3-month duration. Investigations revealed an osteoid osteoma of C2 lamina-lateral mass complex. The patient underwent a posterior microendoscopic excision using 18-mm diameter METRx system (Medtronic Sofamor Danek, Memphis, TN) of tubular retractors. A postoperative computed tomographic scan was done and preoperative and postoperative visual analogue scale and Neck Disability Index were evaluated. The patient was periodically followed up for 1 year. The postoperative computed tomographic scan revealed complete excision of the tumor. The visual analogue scale score for neck pain improved from 3/5 (preoperative) to 0/5 (postoperative) and Neck Disability Index from 33.33 (preoperative) to 0 (postoperative) at 1-year follow-up. Microendoscopic techniques can be extended to excise lesions of the spine. It is a safe procedure in experienced hands. The advantages are minimal morbidity, minimal postoperative pain and discomfort, less analgesic dependence, and better cosmesis. The authors recommend this technique for accessible lesions involving the spine.
Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa
2016-01-01
We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions. PMID:27324109
NASA Astrophysics Data System (ADS)
Pietsch, Patrick; Hess, Michael; Ludwig, Wolfgang; Eller, Jens; Wood, Vanessa
2016-06-01
We present an operando study of a lithium ion battery combining scanning X-ray diffraction (SXRD) and synchrotron radiation X-ray tomographic microscopy (SRXTM) simultaneously for the first time. This combination of techniques facilitates the investigation of dynamic processes in lithium ion batteries containing amorphous and/or weakly attenuating active materials. While amorphous materials pose a challenge for diffraction techniques, weakly attenuating material systems pose a challenge for attenuation-contrast tomography. Furthermore, combining SXRD and SRXTM can be used to correlate processes occurring at the atomic level in the crystal lattices of the active materials with those at the scale of electrode microstructure. To demonstrate the benefits of this approach, we investigate a silicon powder electrode in lithium metal half-cell configuration. Combining SXRD and SRXTM, we are able to (i) quantify the dissolution of the metallic lithium electrode and the expansion of the silicon electrode, (ii) better understand the formation of the Li15Si4 phase, and (iii) non-invasively probe kinetic limitations within the silicon electrode. A simple model based on the 1D diffusion equation allows us to qualitatively understand the observed kinetics and demonstrates why high-capacity electrodes are more prone to inhomogeneous lithiation reactions.
Palejwala, Neal V; Jia, Yali; Gao, Simon S; Liu, Liang; Flaxel, Christina J; Hwang, Thomas S; Lauer, Andreas K; Wilson, David J; Huang, David; Bailey, Steven T
2015-11-01
To evaluate eyes with age-related macular degeneration and high-risk characteristics for choroidal neovascularization (CNV) with optical coherence tomographic (OCT) angiography to determine whether earlier detection of CNV is possible. Eyes with drusen, pigmentary changes, and with CNV in the fellow eye were scanned with a 70-kHz spectral domain OCT system (Optovue RTVue-XR Avanti). The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to distinguish blood flow from static tissue. Two masked graders reviewed scans for CNV, defined as flow in the outer retinal/sub-RPE slab. Choroidal neovascularization flow area repeatability and between-grader reproducibility were calculated. Of 32 eyes, 2 (6%) were found to have Type 1 CNV with OCT angiography. The lesions were not associated with leakage on fluorescein angiography or fluid on OCT. One case was followed for 8 months without treatment, and the CNV flow area enlarged slightly without fluid buildup on OCT or vision loss. Between-grader reproducibility of the CNV flow area was 9.4% (coefficient of variation) and within-visit repeatability was 5.2% (pooled coefficient of variation). Optical coherence tomographic angiography can detect the presence of nonexudative CNV, lesions difficult to identify with fluorescein angiography and OCT. Further study is needed to understand the significance and natural history of these lesions.
Computed tomographic imaging of stapes implants.
Warren, Frank M; Riggs, Sterling; Wiggins, Richard H
2008-08-01
Computed tomographic (CT) imaging of stapes prostheses is inaccurate. Clinical situations arise in which it would be helpful to determine the depth of penetration of a stapes prosthesis into the vestibule. The accuracy of CT imaging for this purpose has not been defined. This study was aimed to determine the accuracy of CT imaging to predict the depth of intrusion of stapes prostheses into the vestibule. The measurement of stapes prostheses by CT scan was compared with physical measurements in 8 cadaveric temporal bones. The depth of intrusion into the vestibule of the piston was underestimated in specimens with the fluoroplastic piston by a mean of 0.5 mm when compared with the measurements obtained in the temporal bones. The depth of penetration of the stainless steel implant was overestimated by 0.5 mm when compared with that in the temporal bone. The type of implant must be taken into consideration when estimating the depth of penetration into the vestibule using CT scanning because the imaging characteristics of the implanted materials differ. The position of fluoroplastic pistons cannot be accurately measured in the vestibule. Metallic implants are well visualized, and measurements exceeding 2.2 mm increase the suspicion of otolithic impingement. Special reconstructions along the length of the piston may be more accurate in estimating the position of stapes implants.
Hageman, G Gerard
2015-01-01
In 2010 the guideline on mild traumatic head/ brain injury for both adults and children was revised under the supervision of the Dutch Neurology Society. The revised guideline endorsed rules for decisions on whether to carry out diagnostic imaging investigations (brain CT scanning) and formulates indications for admission. Unfortunately, 5 years after its introduction, it is clear that the guideline rules result in excessive brain CT scanning, in which no more serious head injury is diagnosed. Brain injury may be present in (small) children even if symptoms are absent at first presentation. Also, clinical signs do not predict intracranial complications. This was nicely demonstrated in a study by Tilma, Bekhof and Brand of 410 children with mTBI: no clinical symptom or sign reliably predicted the risk of intracranial bleeding. They advise hospitalisation for observation instead of brain CT scanning. It may be necessary to review part of the Dutch guideline on mTBI.
Conservative orthodontic treatment of mandibular bilateral condyle fracture.
Gašpar, Goran; Brakus, Ivan; Kovačić, Ivan
2014-09-01
Maxillofacial trauma is rare in children younger than the age of 5 years (range 0.6%-1.2%), and they can require different clinical treatment strategies compared with fractures in the adult population because of concerns regarding mandibular growth and development of dentition. A 5-year-old girl with a history of falling from a bicycle 7 hours earlier was referred to the department of oral and maxillofacial surgery. Multislice computed tomographic examination demonstrated a bilateral fracture of the mandibular condyle neck associated with minimal fracture of the alveolar ridge of the maxilla. The multislice computed tomographic scan also demonstrated dislocation on the right condyle neck and, on the left side, a medial inclination of approximately 45 degrees associated with greenstick fracture of the right parasymphysis region. In this particular case, orthodontic rubber elastics in combination with fixed orthodontic brackets provided good results in the treatment of bilateral condyle neck fractures associated with greenstick fracture of parasymphysis.
Tomographic techniques for the study of exceptionally preserved fossils
Sutton, Mark D
2008-01-01
Three-dimensional fossils, especially those preserving soft-part anatomy, are a rich source of palaeontological information; they can, however, be difficult to work with. Imaging of serial planes through an object (tomography) allows study of both the inside and outside of three-dimensional fossils. Tomography may be performed using physical grinding or sawing coupled with photography, through optical techniques of serial focusing, or using a variety of scanning technologies such as neutron tomography, magnetic resonance imaging and most usefully X-ray computed tomography. This latter technique is applicable at a variety of scales, and when combined with a synchrotron X-ray source can produce very high-quality data that may be augmented by phase-contrast information to enhance contrast. Tomographic data can be visualized in several ways, the most effective of which is the production of isosurface-based ‘virtual fossils’ that can be manipulated and dissected interactively. PMID:18426749
Laser-wakefield accelerators as hard x-ray sources for 3D medical imaging of human bone
Cole, J. M.; Wood, J. C.; Lopes, N. C.; Poder, K.; Abel, R. L.; Alatabi, S.; Bryant, J. S. J.; Jin, A.; Kneip, S.; Mecseki, K.; Symes, D. R.; Mangles, S. P. D.; Najmudin, Z.
2015-01-01
A bright μm-sized source of hard synchrotron x-rays (critical energy Ecrit > 30 keV) based on the betatron oscillations of laser wakefield accelerated electrons has been developed. The potential of this source for medical imaging was demonstrated by performing micro-computed tomography of a human femoral trabecular bone sample, allowing full 3D reconstruction to a resolution below 50 μm. The use of a 1 cm long wakefield accelerator means that the length of the beamline (excluding the laser) is dominated by the x-ray imaging distances rather than the electron acceleration distances. The source possesses high peak brightness, which allows each image to be recorded with a single exposure and reduces the time required for a full tomographic scan. These properties make this an interesting laboratory source for many tomographic imaging applications. PMID:26283308
Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J
1993-01-01
Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.
REVIEWS OF TOPICAL PROBLEMS: Nonlinear dynamics of the brain: emotion and cognition
NASA Astrophysics Data System (ADS)
Rabinovich, Mikhail I.; Muezzinoglu, M. K.
2010-07-01
Experimental investigations of neural system functioning and brain activity are standardly based on the assumption that perceptions, emotions, and cognitive functions can be understood by analyzing steady-state neural processes and static tomographic snapshots. The new approaches discussed in this review are based on the analysis of transient processes and metastable states. Transient dynamics is characterized by two basic properties, structural stability and information sensitivity. The ideas and methods that we discuss provide an explanation for the occurrence of and successive transitions between metastable states observed in experiments, and offer new approaches to behavior analysis. Models of the emotional and cognitive functions of the brain are suggested. The mathematical object that represents the observed transient brain processes in the phase space of the model is a structurally stable heteroclinic channel. The possibility of using the suggested models to construct a quantitative theory of some emotional and cognitive functions is illustrated.
Vigneron, C; Labeye, V; Cour, M; Hannoun, S; Grember, A; Rampon, F; Cotton, F
2016-01-01
Previous studies have shown that a loss of distinction between gray matter (GM) and white matter (WM) on unenhanced CT scans was predictive of poor outcome after cardiac arrest. The aim of this study was to identify a marker/predictor of imminent brain death. In this retrospective study, 15 brain-dead patients after anoxia and cardiac arrest were included. Patients were paired (1:1) with normal control subjects. Only patients' unenhanced CT scans performed before brain death and during the 24 hours after initial signs were analyzed. WM and GM densities were measured in predefined regions of interest (basal ganglia level, centrum semi-ovale level, high convexity level, brainstem level). At each level, GM and WM density and GM/WM ratio for brain-dead patients and normal control subjects were compared using the Wilcoxon signed-rank test. At each level, a lower GM/WM ratio and decreased GM and WM densities were observed in brain-dead patients' CT scans when compared with normal control subject CT scans. A cut-off value of 1.21 at the basal ganglia level was identified, below which brain death systematically occurred. GM/WM dedifferentiation on unenhanced CT scan is measurable before the occurrence of brain death, highlighting its importance in brain death prediction. The mechanism of GM/WM differentiation loss could be explained by the lack of oxygen caused by ischemia initially affecting the mitochondrial system. Copyright © 2016 Elsevier Inc. All rights reserved.
Yang, Yan; Shen, Ya; Ma, Jingzhi; Cao, Yingguang; Haapasalo, Markus
2016-08-01
Micro-computed tomographic scanning was used to evaluate the influence of operator's experience on the time and quality of instrumentation of the mesial root canals of mandibular molars using WaveOne Primary files (Dentsply Maillefer, Ballaigues, Switzerland). Thirty mandibular molars with 2 separate mesial canals were submitted to preoperative micro-CT scans. Teeth were randomly allocated to 3 groups: and experienced operator group and inexperienced groups before and after training with WaveOne files. Second scans were obtained after instrumentation. The volume of the untreated canal, the volume of dentin removed after preparation; the amount of the uninstrumented area; and transportation to the coronal, middle, and apical thirds of canals were measured. The preparation time was also recorded. Instrumentation of canals increased their volume and surface area in all groups. No significant differences between experienced and inexperienced (with and without training) groups in the apical, middle, and coronal sections were detected although coronal transportation was slightly larger in both inexperienced groups than in the experienced group. The inexperienced operator without training used significantly more time for instrumentation than the experienced operator (P < .05); after training for 1 month, the instrumentation time by the same inexperienced operator was reduced (P < .05) to close to the time of the experienced operator (P > .05). The WaveOne instrumentation technique required a short learning curve for the inexperienced user in order to master this technology. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Lara-Mendes, Sônia T de O; Barbosa, Camila de Freitas M; Santa-Rosa, Caroline C; Machado, Vinícius C
2018-05-01
The aim of this study was to describe a guided endodontic technique that facilitates access to root canals of molars presenting with pulp calcifications. A 61-year-old woman presented to our service with pain in the upper left molar region. The second and third left molars showed signs of apical periodontitis confirmed by the cone-beam computed tomographic (CBCT) scans brought to us by the patient at the initial appointment. Conventional endodontic treatment was discontinued given the difficulty in locating the root canals. Intraoral scanning and the CBCT scans were used to plan the access to the calcified canals by means of implant planning software. Guides were fabricated through rapid prototyping and allowed for the correct orientation of a cylindrical drill used to provide access through the calcifications. Second to that, the root canals were prepared with reciprocating endodontic instruments and rested for 2 weeks with intracanal medication. Subsequently, canals were packed with gutta-percha cones using the hydraulic compression technique. Permanent restorations of the access cavities were performed. By comparing the tomographic images, the authors observed a drastic reduction of the periapical lesions as well as the absence of pain symptoms after 3 months. This condition was maintained at the 1-year follow-up. The guided endodontic technique in maxillary molars was shown to be a fast, safe, and predictable therapy and can be regarded as an excellent option for the location of calcified root canals, avoiding failures in complex cases. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Nia, Emily S; Garland, Linda L; Eshghi, Naghmehossadat; Nia, Benjamin B; Avery, Ryan J; Kuo, Phillip H
2017-09-01
The brain is the most common site of distant metastasis from lung cancer. Thus, MRI of the brain at initial staging is routinely performed, but if this examination is negative a follow-up examination is often not performed. This study evaluates the incidence of asymptomatic brain metastases in non-small cell lung cancer patients detected on follow-up 18 F-FDG PET/CT scans. Methods: In this Institutional Review Board-approved retrospective review, all vertex to thigh 18 F-FDG PET/CT scans in patients with all subtypes of lung cancer from August 2014 to August 2016 were reviewed. A total of 1,175 18 F-FDG PET/CT examinations in 363 patients were reviewed. Exclusion criteria included brain metastases on initial staging, histologic subtype of small-cell lung cancer, and no follow-up 18 F-FDG PET/CT examinations. After our exclusion criteria were applied, a total of 809 follow-up 18 F-FDG PET/CT scans in 227 patients were included in the final analysis. The original report of each 18 F-FDG PET/CT study was reviewed for the finding of brain metastasis. The finding of a new brain metastasis prompted a brain MRI, which was reviewed to determine the accuracy of the 18 F-FDG PET/CT. Results: Five of 227 patients with 809 follow-up 18 F-FDG PET/CT scans reviewed were found to have incidental brain metastases. The mean age of the patients with incidental brain metastasis was 68 y (range, 60-77 y). The mean time from initial diagnosis to time of detection of incidental brain metastasis was 36 mo (range, 15-66 mo). When MRI was used as the gold standard, our false-positive rate was zero. Conclusion: By including the entire head during follow-up 18 F-FDG PET/CT scans of patients with non-small cell lung cancer, brain metastases can be detected earlier while still asymptomatic. But, given the additional scan time, radiation, and low incidence of new brain metastases in asymptomatic patients, the cost-to-benefit ratio should be weighed by each institution. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
EARLY VERSUS LATE MRI IN ASPHYXIATED NEWBORNS TREATED WITH HYPOTHERMIA
Wintermark, Pia; Hansen, Anne; Soul, Janet; Labrecque, Michelle; Robertson, Richard L.; Warfield, Simon K.
2012-01-01
Objective The purposes of this feasibility study are to assess: (1) the potential utility of early brain magnetic resonance imaging (MRI) in asphyxiated newborns treated with hypothermia; (2) whether early MRI predicts later brain injury observed in these newborns after hypothermia is completed; and (3) whether early MRI indicators of brain injury in these newborns represent reversible changes. Patients and Methods All consecutive asphyxiated term newborns meeting the criteria for therapeutic hypothermia were enrolled prospectively. Each of them underwent 1–2 “early” MRI scans while receiving hypothermia, on day of life (DOL) 1 and DOL 2–3, and also 1–2 “late” MRI scans on DOL 8–13 and at 1 month of age. Results Thirty-seven MRI scans were obtained in twelve asphyxiated neonates treated with induced hypothermia. Four newborns did develop MRI evidence of brain injury, already visible on early MRI scans. The remaining eight newborns did not develop significant MRI evidence of brain injury on any of the MRI scans. In addition, two patients displayed unexpected findings on early MRIs, leading to early termination of hypothermia treatment. Conclusions MRI scans obtained on DOL 2–3 during hypothermia seem to predict later brain injuries in asphyxiated newborns in this feasibility study. Brain injuries identified during this early time appear to represent irreversible changes. Early MRI scans might also be useful to demonstrate unexpected findings not related to hypoxic-ischemic encephalopathy, which could potentially be exacerbated by induced hypothermia. Additional studies with larger numbers of patients will be useful to more definitively confirm these results. PMID:20688865
Fast tomosynthesis for lung cancer detection using the SBDX geometry
NASA Astrophysics Data System (ADS)
Fahrig, Rebecca; Pineda, Angel R.; Solomon, Edward G.; Leung, Ann N.; Pelc, Norbert J.
2003-06-01
Radiology-based lung-cancer detection is a high-contrast imaging task, consisting of the detection of a small mass of tissue within much lower density lung parenchyma. This imaging task requires removal of confounding image details, fast image acquisition (< 0.1 s for pericardial region), low dose (comparable to a chest x-ray), high resolution (< 0.25 mm in-plane) and patient positioning flexibility. We present an investigation of tomosynthesis, implemented using the Scanning-Beam Digital X-ray System (SBDX), to achieve these goals. We designed an image-based computer model of tomosynthesis using a high-resolution (0.15-mm isotropic voxels), low-noise CT volume image of a lung phantom, numerically added spherical lesions and convolution-based tomographic blurring. Lesion visibility was examined as a function of half-tomographic angle for 2.5 and 4.0 mm diameter lesions. Gaussian distributed noise was added to the projected images. For lesions 2.5 mm and 4.0 mm in diameter, half-tomographic angles of at least 6° and 9° respectively were necessary before visualization of the lesions improved. The addition of noise for a dose equivalent to 1/10 that used for a standard chest radiograph did not significantly impair lesion detection. The results are promising, indicating that lung-cancer detection using a modified SBDX system is possible.
NASA Astrophysics Data System (ADS)
Kazantsev, Daniil; Pickalov, Valery; Nagella, Srikanth; Pasca, Edoardo; Withers, Philip J.
2018-01-01
In the field of computerized tomographic imaging, many novel reconstruction techniques are routinely tested using simplistic numerical phantoms, e.g. the well-known Shepp-Logan phantom. These phantoms cannot sufficiently cover the broad spectrum of applications in CT imaging where, for instance, smooth or piecewise-smooth 3D objects are common. TomoPhantom provides quick access to an external library of modular analytical 2D/3D phantoms with temporal extensions. In TomoPhantom, quite complex phantoms can be built using additive combinations of geometrical objects, such as, Gaussians, parabolas, cones, ellipses, rectangles and volumetric extensions of them. Newly designed phantoms are better suited for benchmarking and testing of different image processing techniques. Specifically, tomographic reconstruction algorithms which employ 2D and 3D scanning geometries, can be rigorously analyzed using the software. TomoPhantom also provides a capability of obtaining analytical tomographic projections which further extends the applicability of software towards more realistic, free from the "inverse crime" testing. All core modules of the package are written in the C-OpenMP language and wrappers for Python and MATLAB are provided to enable easy access. Due to C-based multi-threaded implementation, volumetric phantoms of high spatial resolution can be obtained with computational efficiency.
System Performance Simulations of the RatCAP Awake Rat Brain Scanner
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.
2005-10-01
The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.
... Treatment Window for Stroke Follow us Brain Scan Technology Extends Treatment Window for Stroke Some stroke patients ... after a stroke happens—thanks to brain imaging technology. But researchers emphasize that stroke is still an ...
Towards the Experimental Assessment of the DQE in SPECT Scanners
NASA Astrophysics Data System (ADS)
Fountos, G. P.; Michail, C. M.
2017-11-01
The purpose of this work was to introduce the Detective Quantum Efficiency (DQE) in single photon emission computed tomography (SPECT) systems using a flood source. A Tc-99m-based flood source (Eγ = 140 keV) consisting of a radiopharmaceutical solution of dithiothreitol (DTT, 10-3 M)/Tc-99m(III)-DMSA, 40 mCi/40 ml bound to the grains of an Agfa MammoRay HDR Medical X-ray film) was prepared in laboratory. The source was placed between two PMMA blocks and images were obtained by using the brain tomographic acquisition protocol (DatScan-brain). The Modulation Transfer Function (MTF) was evaluated using the Iterative 2D algorithm. All imaging experiments were performed in a Siemens e-Cam gamma camera. The Normalized Noise Power spectra (NNPS) were obtained from the sagittal views of the source. The higher MTF values were obtained for the Flash Iterative 2D with 24 iterations and 20 subsets. The noise levels of the SPECT reconstructed images, in terms of the NNPS, were found to increase as the number of iterations increase. The behavior of the DQE was influenced by both MTF and NNPS. As the number of iterations was increased, higher MTF values were obtained, however with a parallel, increase of magnitude in image noise, as depicted from the NNPS results. DQE values, which were influenced by both MTF and NNPS, were found higher when the number of iterations results in resolution saturation. The method presented here is novel and easy to implement, requiring materials commonly found in clinical practice and can be useful in the quality control of SPECT scanners.
Hyponatremia in Traumatic Brain Injury: A Practical Management Protocol.
Rajagopal, Ramanan; Swaminathan, Ganesh; Nair, Shalini; Joseph, Mathew
2017-12-01
Hyponatremia (defined as serum sodium <135 mEq/L) is the most common electrolyte abnormality in traumatic brain injury (TBI) and is also an independent predictor of poor neurologic outcome. The reported incidence of hyponatremia varies widely in literature reports, and there is continuing difficulty in clearly differentiating between the 2 common causes of hyponatremia with natriuresis: the syndrome of inappropriate antidiuretic hormone secretion (SIADH) and cerebral salt wasting (CSW). We encounter hyponatremia frequently in our practice, and we therefore decided to review data from our center to estimate the incidence of hyponatremia and the results of our management strategies, and attempt to formulate simple guidelines for the correction of hyponatremia in TBI. A retrospective analysis of 1500 consecutively admitted patients with TBI was performed by the use of electronic records and radiographic review. Hyponatremia was defined as serum sodium <135 mEq/L, and natriuresis as a urine spot sodium of more than >40 mEq/L. The incidence of TBI, its management, and the effect of fludrocortisone were evaluated. The incidence of hyponatremia was 13.2%. Early therapy with fludrocortisone significantly reduced the duration of hospital stay (P < 0.05). Traumatic subarachnoid hemorrhage was the most common abnormality on the admission computed tomographic scan in patients who experienced hyponatremia. Early initiation of fludrocortisone in the setting of hyponatremia with natriuresis decreases the hospital stay. This protocol is probably safer in a tropical country where fluid restriction might be harmful. It also eliminates the need to differentiate between SIADH and CSW. Copyright © 2017. Published by Elsevier Inc.
Freed, K S; Paulson, E K; Frederick, M G; Keogan, M T; Pappas, T N
1997-06-01
To evaluate the postoperative computed tomographic (CT) appearance, complications, and potential pitfalls after a Puestow procedure (lateral side-to-side pancreaticojejunostomy). Forty CT examinations were performed after the Puestow procedure in 20 patients. Images were retrospectively reviewed by three radiologists. The pancreaticojejunal anastomosis was identified at 30 examinations and was immediately anterior to the pancreatic body or tail. The anastomosis contained fluid or gas on 11 scans and oral contrast material on four scans. On 15 scans, the anastomosis appeared as collapsed bowel without gas, fluid, or oral contrast material. The Roux-en-Y loop was identified on 28 (70%) scans and contained fluid or gas on 16 scans and oral contrast material on six scans. The Roux-en-Y loop appeared as collapsed bowel on six scans. When the anastomosis or Roux-en-Y loop contained fluid and gas, the appearance mimicked that of a pancreatic or parapancreatic abscess. Peripancreatic stranding was present on 28 scans and was due to either ongoing pancreatitis or postoperative change. Complications included 15 transient fluid collections, three abscesses, four pseudocysts, one hematoma, and one small-bowel and Roux-en-Y obstruction. Knowledge of the anatomy after a Puestow procedure is essential for accurate interpretation of CT scans.
Arsznov, Bradley M; Sakai, Sharleen T
2013-01-01
The present study investigated whether increased relative brain size, including regional brain volumes, is related to differing behavioral specializations exhibited by three member species of the family Procyonidae. Procyonid species exhibit continuums of behaviors related to social and physical environmental complexities: the mostly solitary, semiarboreal and highly dexterous raccoons (Procyon lotor); the exclusively arboreal kinkajous (Potos flavus), which live either alone or in small polyandrous family groups, and the social, terrestrial coatimundi (Nasua nasua, N. narica). Computed tomographic (CT) scans of 45 adult skulls including 17 coatimundis (9 male, 8 female), 14 raccoons (7 male, 7 female), and 14 kinkajous (7 male, 7 female) were used to create three-dimensional virtual endocasts. Endocranial volume was positively correlated with two separate measures of body size: skull basal length (r = 0.78, p < 0.01) and basicranial axis length (r = 0.45, p = 0.002). However, relative brain size (total endocranial volume as a function of body size) varied by species depending on which body size measurement (skull basal length or basicranial axis length) was used. Comparisons of relative regional brain volumes revealed that the anterior cerebrum volume consisting mainly of frontal cortex and surface area was significantly larger in the social coatimundi compared to kinkajous and raccoons. The dexterous raccoon had the largest relative posterior cerebrum volume, which includes the somatosensory cortex, in comparison to the other procyonid species studied. The exclusively arboreal kinkajou had the largest relative cerebellum and brain stem volume in comparison to the semi arboreal raccoon and the terrestrial coatimundi. Finally, intraspecific comparisons failed to reveal any sex differences, except in the social coatimundi. Female coatimundis possessed a larger relative frontal cortical volume than males. Social life histories differ in male and female coatimundis but not in either kinkajous or raccoons. This difference may reflect the differing social life histories experienced by females who reside in their natal bands, and forage and engage in antipredator behavior as a group, while males disperse upon reaching adulthood and are usually solitary thereafter. This analysis in the three procyonid species supports the comparative neurology principle that behavioral specializations correspond to an expansion of neural tissue involved in that function.
ERIC Educational Resources Information Center
Stamatakis, E.A.; Tyler, L.K.
2005-01-01
The study of neuropsychological disorders has been greatly facilitated by the localization of brain lesions on MRI scans. Current popular approaches for the assessment of MRI brain scans mostly depend on the successful segmentation of the brain into grey and white matter. These methods cannot be used effectively with large lesions because lesions…
Onset of multiple sclerosis before adulthood leads to failure of age-expected brain growth
Aubert-Broche, Bérengère; Fonov, Vladimir; Narayanan, Sridar; Arnold, Douglas L.; Araujo, David; Fetco, Dumitru; Till, Christine; Sled, John G.; Collins, D. Louis
2014-01-01
Objective: To determine the impact of pediatric-onset multiple sclerosis (MS) on age-expected brain growth. Methods: Whole brain and regional volumes of 36 patients with relapsing-remitting MS onset prior to 18 years of age were segmented in 185 longitudinal MRI scans (2–11 scans per participant, 3-month to 2-year scan intervals). MRI scans of 25 age- and sex-matched healthy normal controls (NC) were also acquired at baseline and 2 years later on the same scanner as the MS group. A total of 874 scans from 339 participants from the NIH-funded MRI study of normal brain development acquired at 2-year intervals were used as an age-expected healthy growth reference. All data were analyzed with an automatic image processing pipeline to estimate the volume of brain and brain substructures. Mixed-effect models were built using age, sex, and group as fixed effects. Results: Significant group and age interactions were found with the adjusted models fitting brain volumes and normalized thalamus volumes (p < 10−4). These findings indicate a failure of age-normative brain growth for the MS group, and an even greater failure of thalamic growth. In patients with MS, T2 lesion volume correlated with a greater reduction in age-expected thalamic volume. To exclude any scanner-related influence on our data, we confirmed no significant interaction of group in the adjusted models between the NC and NIH MRI Study of Normal Brain Development groups. Conclusions: Our results provide evidence that the onset of MS during childhood and adolescence limits age-expected primary brain growth and leads to subsequent brain atrophy, implicating an early onset of the neurodegenerative aspect of MS. PMID:25378667
Development of low-dose photon-counting contrast-enhanced tomosynthesis with spectral imaging.
Schmitzberger, Florian F; Fallenberg, Eva Maria; Lawaczeck, Rüdiger; Hemmendorff, Magnus; Moa, Elin; Danielsson, Mats; Bick, Ulrich; Diekmann, Susanne; Pöllinger, Alexander; Engelken, Florian J; Diekmann, Felix
2011-05-01
To demonstrate the feasibility of low-dose photon-counting tomosynthesis in combination with a contrast agent (contrast material-enhanced tomographic mammography) for the differentiation of breast cancer. All studies were approved by the institutional review board, and all patients provided written informed consent. A phantom model with wells of iodinated contrast material (3 mg of iodine per milliliter) 1, 2, 5, 10, and 15 mm in diameter was assessed. Nine patients with malignant lesions and one with a high-risk lesion (atypical papilloma) were included (all women; mean age, 60.7 years). A multislit photon-counting tomosynthesis system was utilized (spectral imaging) to produce both low- and high-energy tomographic data (below and above the k edge of iodine, respectively) in a single scan, which allowed for dual-energy visualization of iodine. Images were obtained prior to contrast material administration and 120 and 480 seconds after contrast material administration. Four readers independently assessed the images along with conventional mammograms, ultrasonographic images, and magnetic resonance images. Glandular dose was estimated. Contrast agent was visible in the phantom model with simulated spherical tumor diameters as small as 5 mm. The average glandular dose was measured as 0.42 mGy per complete spectral imaging tomosynthesis scan of one breast. Because there were three time points (prior to contrast medium administration and 120 and 480 seconds after contrast medium administration), this resulted in a total dose of 1.26 mGy for the whole procedure in the breast with the abnormality. Seven of 10 cases were categorized as Breast Imaging Reporting and Data System score of 4 or higher by all four readers when reviewing spectral images in combination with mammograms. One lesion near the chest wall was not captured on the spectral image because of a positioning problem. The use of contrast-enhanced tomographic mammography has been demonstrated successfully in patients with promising diagnostic benefit. Further studies are necessary to fully assess diagnostic sensitivity and specificity. RSNA, 2011
Look again: effects of brain images and mind-brain dualism on lay evaluations of research.
Hook, Cayce J; Farah, Martha J
2013-09-01
Brain scans have frequently been credited with uniquely seductive and persuasive qualities, leading to claims that fMRI research receives a disproportionate share of public attention and funding. It has been suggested that functional brain images are fascinating because they contradict dualist beliefs regarding the relationship between the body and the mind. Although previous research has indicated that brain images can increase judgments of an article's scientific reasoning, the hypotheses that brain scans make research appear more interesting, surprising, or worthy of funding have not been tested. Neither has the relation between the allure of brain imaging and dualism. In the following three studies, laypersons rated both fictional research descriptions and real science news articles accompanied by brain scans, bar charts, or photographs. Across 988 participants, we found little evidence of neuroimaging's seductive allure or of its relation to self-professed dualistic beliefs. These results, taken together with other recent null findings, suggest that brain images are less powerful than has been argued.
Singh, Mansher; Ricci, Joseph A.
2015-01-01
Background: In patients with panfacial fractures and distorted anatomic landmarks of zygomatic and orbital complex, there is a risk of zygomaticomaxillary complex (ZMC) malpositioning even with the best efforts for surgical repair. This results in increased number of additional procedures to achieve accurate positioning. Methods: We describe the usage of intraoperative C-arm cone-beam computed tomographic (CT) scan for ZMC malpositioning in a representative patient with panfacial fractures. Results: We have successfully used intraoperative CT scan for ZMC malpositioning in 3 patients. The representative patient had ZMC malposition after the initial attempt of surgical repair without any intraoperative imaging. On using intraoperative CT scan during the next attempt, we were able to reposition the ZMC accurately. Conclusions: Intraoperative CT scan might improve the accuracy of ZMC positioning and decrease the chances of potential additional surgeries. In patients with distorted anatomical landmarks and panfacial fractures, it can be especially helpful toward correcting ZMC malposition. PMID:26301152
Portable Ultrasound Imaging of the Brain for Use in Forward Battlefield Areas
2011-03-01
ultrasound measurement of skull thickness and sound speed, phase correction of beam distortion, the tomographic reconstruction algorithm, and the final...produce a coherent imaging source. We propose a corrective technique that will use ultrasound-based phased -array beam correction [3], optimized...not expected to be a significant factor in the ability to phase -correct the imaging beam . In addition to planning (2.2.1), the data is also be used
Fusion of MRIs and CT scans for surgical treatment of cholesteatoma of the middle ear in children.
Plouin-Gaudon, Isabelle; Bossard, Denis; Ayari-Khalfallah, Sonia; Froehlich, Patrick
2010-09-01
To evaluate the efficiency of diffusion-weighted magnetic resonance imaging (MRI) and high-resolution computed tomographic (CT) scan coregistration in predicting and adequately locating primary or recurrent cholesteatoma in children. Prospective study. Tertiary care university hospital. Ten patients aged 2 to 17 years (mean age, 8.5 years) with cholesteatoma of the middle ear, some of which were previously treated, were included for follow-up with systematic CT scanning and MRI between 2007 and 2008. Computed tomographic scanning was performed on a Siemens Somaton 128 (0.5/0.2-mm slices reformatted in 0.5/0.3-mm images). Fine cuts were obtained parallel and perpendicular to the lateral semicircular canal in each ear (100 × 100-mm field of view). Magnetic resonance imaging was undertaken on a Siemens Avanto 1.5T unit, with a protocol adapted for young children. Diffusion-weighted imaging was acquired using a single-shot turbo spin-echo mode. To allow for diagnosis and localization of the cholesteatoma, CT and diffusion-weighted MRIs were fused for each case. In 10 children, fusion technique allowed for correct diagnosis and precise localization (hypotympanum, epitympanum, mastoid recess, and attical space) as confirmed by subsequent standard surgery (positive predictive value, 100%). In 3 cases, the surgical approach was adequately determined from the fusion results. Lesion sizes on the CT-MRI fusion corresponded with perioperative findings. Recent developments in imaging techniques have made diffusion-weighted MRI more effective for detecting recurrent cholesteatoma. The major drawback of this technique, however, has been its poor anatomical and spatial discrimination. Fusion imaging using high-resolution CT and diffusion-weighted MRI appears to be a promising technique for both the diagnosis and precise localization of cholesteatomas. It provides useful information for surgical planning and, furthermore, is easy to use in pediatric cases.
Hemispherical Scanning Imaging DOAS: Resolving nitrogen dioxide in the urban environment
NASA Astrophysics Data System (ADS)
Leigh, R. J.; Graves, R. R.; Lawrence, J.; Faloon, K.; Monks, P. S.
2012-12-01
Imaging DOAS techniques have been used for nitrogen dioxide and sulfer dioxide for a number of years. This presentation describes a novel system which images concentrations of nitrogen dioxide by scanning an imaging spectrometer 360 degrees azimuthally, covering a region from 5 degrees below the horizon, to the zenith. The instrument has been built at the University of Leicester (UK), on optical designs by Surrey Satellite Technologies Ltd, and incorporates an Offner relay with Schwarzchild fore-optics, in a rotating mount. The spectrometer offers high fidelity spectroscopic retrievals of nitrogen dioxide as a result of a reliable Gaussian line shape, zero smile and low chromatic aberration. The full hemispherical scanning provides complete coverage of nitrogen dioxide concentrations above approximately 5 ppbv in urban environments. Through the use of multiple instruments, the three-dimensional structure of nitrogen dioxide can be sampled and tomographically reconstructed, providing valuable information on nitrogen dioxide emissions and downwind exposure, in addition to new understanding of boundary layer dynamics through the use of nitrogen dioxide as a tracer. Furthermore, certain aerosol information can be retrieved through absolute intensity measurements in each azimuthal direction supplemented by traditional techniques of O4 spectroscopy. Such measurements provide a new tool for boundary layer measurement and monitoring at a time when air quality implications on human health and climate are under significant scrutiny. This presentation will describe the instrument and tomographic potential of this technique. First measurements were taken as part of the international PEGASOS campaign in Bologna, Italy. Results from these measurements will be shown, including imaging of enhanced NO2 in the Bologna urban boundary layer during a severe thunderstorm. A Hemispherical Scanning Imaging DOAS instrument operating in Bologna, Italy in June 2012. Visible in the background over Bologna is an instrumented Zepplin measuring NO2 and ozone among other species. A hemispherical panorama of nitrogen dioxide concentrations, as measured by the HSI-DOAS instrument in Bologna.
Grundman, Michael; Pontecorvo, Michael J; Salloway, Stephen P; Doraiswamy, P Murali; Fleisher, Adam S; Sadowsky, Carl H; Nair, Anil K; Siderowf, Andrew; Lu, Ming; Arora, Anupa K; Agbulos, Abigail; Flitter, Matthew L; Krautkramer, Michael J; Sarsour, Khaled; Skovronsky, Daniel M; Mintun, Mark A
2013-01-01
Florbetapir F18 has been approved by the Food and Drug Administration for in vivo assessment of amyloid pathology in patients undergoing evaluation for Alzheimer disease (AD). The aim of this study was to determine the impact of amyloid imaging on the diagnoses and management of patients undergoing evaluation for cognitive decline. Patients were recruited to participate at 19 clinical sites. The site physician provided a provisional diagnosis, an estimate of their diagnostic confidence, and their plan for diagnostic evaluation and management both before and after receiving the results from amyloid imaging with florbetapir F18. Analyses compared the frequency of AD and non-AD diagnoses, plans for ancillary testing, and intended patient management before and after florbetapir imaging. A total of 229 patients participated in the trial (113 amyloid positive, 116 amyloid negative). After receiving the results of the florbetapir scan, diagnosis changed in 125/229, or 54.6% [95% confidence intervals (CI), 48.1%-60.9%], of cases, and diagnostic confidence increased by an average of 21.6% (95% CI, 18.3%-24.8%). A total of 199/229 or 86.9% (95% CI, 81.9%-90.7%) of cases had at least 1 change in their management plan. Intended cholinesterase inhibitor or memantine treatment increased by 17.7% (95% CI, 11.8%-25.8%) of all cases with positive scans and decreased by 23.3% (95% CI, 16.5%-31.8%) of all those with negative scans. Among subjects who had not yet undergone a completed work up, planned brain structural imaging (computed tomographic/magnetic resonance imaging) decreased by 24.4% (95% CI, 17.5%-32.8%) and planned neuropsychological testing decreased by 32.8% (95% CI, 25.0%-41.6%). In summary, amyloid imaging results altered physician's diagnostic thinking, intended testing, and management of patients undergoing evaluation for cognitive decline.
A comparison of sequential and spiral scanning techniques in brain CT.
Pace, Ivana; Zarb, Francis
2015-01-01
To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).
Kokosi, Maria; Lo, Pechin; Kim, Hyun J.; Ravenel, James G.; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X.
2016-01-01
Rationale: The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. Objectives: To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. Methods: We determined the baseline to 12-month change in computed tomographic image–derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. Measurements and Main Results: There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image–derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. −0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Conclusions: Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying. PMID:26799509
Argula, Rahul G; Kokosi, Maria; Lo, Pechin; Kim, Hyun J; Ravenel, James G; Meyer, Cristopher; Goldin, Jonathan; Lee, Hye-Seung; Strange, Charlie; McCormack, Francis X
2016-03-01
The Multicenter International Lymphangioleiomyomatosis Efficacy and Safety of Sirolimus (MILES) trial demonstrated that sirolimus stabilized lung function and improved measures of functional performance and quality of life in patients with lymphangioleiomyomatosis. The physiologic mechanisms of these beneficial actions of sirolimus are incompletely understood. To prospectively determine the longitudinal computed tomographic lung imaging correlates of lung function change in MILES patients treated with placebo or sirolimus. We determined the baseline to 12-month change in computed tomographic image-derived lung volumes and the volume of the lung occupied by cysts in the 31 MILES participants (17 in sirolimus group, 14 in placebo group) with baseline and 12-month scans. There was a trend toward an increase in median expiratory cyst volume percentage in the placebo group and a reduction in the sirolimus group (+2.68% vs. +0.97%, respectively; P = 0.10). The computed tomographic image-derived residual volume and the ratio of residual volume to total lung capacity increased more in the placebo group than in the sirolimus group (+214.4 ml vs. +2.9 ml [P = 0.054] and +0.05 ml vs. -0.01 ml [P = 0.0498], respectively). A Markov transition chain analysis of respiratory cycle cyst volume changes revealed greater dynamic variation in the sirolimus group than in the placebo group at the 12-month time point. Collectively, these data suggest that sirolimus attenuates progressive gas trapping in lymphangioleiomyomatosis, consistent with a beneficial effect of the drug on airflow obstruction. We speculate that a reduction in lymphangioleiomyomatosis cell burden around small airways and cyst walls alleviates progressive airflow limitation and facilitates cyst emptying.
Diagnostic criteria and follow-up in neuroendocrine cell hyperplasia of infancy: a case series*
Gomes, Vivianne Calheiros Chaves; Silva, Mara Cristina Coelho; Maia, José Holanda; Daltro, Pedro; Ramos, Simone Gusmão; Brody, Alan S.; Marchiori, Edson
2013-01-01
OBJECTIVE: Neuroendocrine cell hyperplasia of infancy (NEHI) is a form of childhood interstitial lung disease characterized by tachypnea, retractions, crackles, and hypoxia. The aim of this study was to report and discuss the clinical, imaging, and histopathological findings in a series of NEHI cases at a tertiary pediatric hospital, with an emphasis on diagnostic criteria and clinical outcomes. METHODS: Between 2003 and 2011, 12 full-term infants were diagnosed with NEHI, based on clinical and tomographic findings. Those infants were followed for 1-91 months. Four infants were biopsied, and the histopathological specimens were stained with bombesin antibody. RESULTS: In this case series, symptoms appeared at birth in 6 infants and by 3 months of age in the remaining 6. In all of the cases, NEHI was associated with acute respiratory infection. The most common initial chest HRCT findings were ground-glass opacities that were in the middle lobe/lingula in 12 patients and in other medullary areas in 10. Air trapping was the second most common finding, being observed in 7 patients. Follow-up HRCT scans (performed in 10 patients) revealed normal results in 1 patient and improvement in 9. The biopsy findings were nonspecific, and the staining was positive for bombesin in all samples. Confirmation of NEHI was primarily based on clinical and tomographic findings. Symptoms improved during the follow-up period (mean, 41 months). A clinical cure was achieved in 4 patients. CONCLUSIONS: In this sample of patients, the diagnosis of NEHI was made on the basis of the clinical and tomographic findings, independent of the lung biopsy results. Most of the patients showed clinical improvement and persistent tomographic changes during the follow-up period, regardless of the initial severity of the disease or type of treatment. PMID:24310630
Jeon, Sun Kyung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Cho, Yeon Jin; Ha, Ji Young; Lee, Seung Hyun; Hyun, Hyejin; Kim, In-One
2018-04-01
The 320-row multidetector computed tomography (CT) scanner has multiple scan modes, including volumetric modes. To compare the image quality and radiation dose of 320-row CT in three acquisition modes - helical, one-shot volume, and wide-volume scan - at pediatric brain imaging. Fifty-seven children underwent unenhanced brain CT using one of three scan modes (helical scan, n=21; one-shot volume scan, n=17; wide-volume scan, n=19). For qualitative analysis, two reviewers evaluated overall image quality and image noise using a 5-point grading system. For quantitative analysis, signal-to-noise ratio, image noise and posterior fossa artifact index were calculated. To measure the radiation dose, adjusted CT dose index per unit volume (CTDI adj ) and dose length product (DLP) were compared. Qualitatively, the wide-volume scan showed significantly less image noise than the helical scan (P=0.009), and less streak artifact than the one-shot volume scan (P=0.001). The helical mode showed significantly lower signal-to-noise ratio, with a higher image noise level compared with the one-shot volume and wide-volume modes (all P<0.05). The CTDI adj and DLP were significantly lower in the one-shot volume and wide-volume modes compared with those in the helical scan mode (all P<0.05). For pediatric unenhanced brain CT, both the wide-volume and one-shot volume scans reduced radiation dose compared to the helical scan mode, while the wide-volume scan mode showed fewer streak artifacts in the skull vertex and posterior fossa than the one-shot volume scan.
Cerebellar syndrome with hydrocephalus due to Mycoplasma pneumoniae infection.
Coleman, R. J.; Brown, J. S.; Butler, P.; Swash, M.
1990-01-01
A 27 year old woman developed a cerebellar syndrome with serological evidence of recent Mycoplasma pneumoniae infection. The cranial computed tomographic scan showed effacement of the fourth ventricle, enhancement of the basal meninges and hydrocephalus affecting the lateral and third ventricles. Clinical and radiological recovery occurred over 5 weeks. We propose that this was a manifestation of immune-mediated encephalomyelitis induced by the infection rather than direct invasion of the central nervous system. Images Figure 1 PMID:2217014
Fluorescence tomography using synchrotron radiation at the NSLS
NASA Astrophysics Data System (ADS)
Boisseau, P.; Grodzins, L.
1987-03-01
Fluorescence tomography utilizing focussed, tunable, monoenergetic X-rays from synchrotron light sources hold the promise of a non-invasive analytic tool for studying trace elements in specimens, particularly biological, at spatial resolutions of the order of micrometers. This note reports an early test at the National Synchrotron Light Source at Brookhaven National Laboratories in which fluorescence tomographic scans were successfully made of trace elements of iron and titanium in NBS standard glass and in a bee.
Mylvaganam, Saba
2018-01-01
This paper presents a concept for soft field tomographic scan of all the projections of electromagnetic waves emanating from an array of electrodes. Instead of the sequential excitation of all pairs of electrodes in the list of all projections, the new method present here consists of a single and continuous excitation. This excitation signal is the linear combination of the excitation signals in the projection set at different AC frequencies. The response to a given projection is discriminated by selecting the corresponding AC frequency component in the signal spectra of the digitally demodulated signals. The main advantage of this method is the suppression of transients after each projection, which is particularly problematic in electrical impedance tomography due to contact impedance phenomena and skin effect. The second benefit over the sequential scan method is the increased number of samples for each measurement for reduced noise sensitivity with digital demodulation. The third benefit is the increased temporal resolution in high-speed applications. The main drawback is the increased number of signal sources required (one per electrode). This paper focuses on electrical impedance tomography, based on earlier work by the authors. An experimental proof-of-concept using a simple 4-electrodes electrical impedance tomographic system is presented using simulations and laboratory data. The method presented here may be extended to other modalities (ultrasonic, microwave, optical, etc.). PMID:29597327
False positive computed tomographic angiography for Stanford type A aortic dissection.
Bandali, Murad F; Hatem, Muhammed A; Appoo, Jehangir J; Hutchison, Stuart J; Wong, Jason K
2015-12-01
Computed tomographic angiography (CTA) has emerged as the defacto imaging test to rule out acute aortic dissection; however, it is not without flaws. We report a case of a false-positive CTA with respect to Stanford Type A aortic dissection. A 52 year-old male presented with sudden onset shortness of breath. He denied chest pain. Due to severe hypertension and an Emergency Department bedside ultrasound suggesting an intimal flap in the aorta, CTA was requested to better assess the ascending aorta and was interpreted as consistent with Stanford Type A aortic dissection with thrombosis of the false lumen in the ascending aorta. However, intra-operative imaging (TEE and epi-aortic scanning) did not identify an intimal flap or dissection, and neither did definitive surgical inspection of the aorta. The suspected aortic dissection and thrombosed false lumen were not visualized on repeat CTA two days later. False positive diagnosis of Stanford Type A aortic dissection on CTA can be the result of technical factors, streak artifacts, motion artifacts, and periaortic structures. In this case, non-uniform arterial contrast enhancement secondary to unrecognized biventricular dysfunction resulted in the false positive CTA appearance of an intimal flap and mural thrombus. Intra-operative TEE and epi-aortic scanning were proven correct in excluding aortic dissection by the standard of definitive surgical inspection of the aorta.
Brain SPECT scans in students with specific learning disability: Preliminary results.
Karande, S; Deshmukh, N; Rangarajan, V; Agrawal, A; Sholapurwala, R
2018-06-08
Brain single-photon emission computed tomography (SPECT) assesses brain function through measurement of regional cerebral blood flow. This study was conducted to assess whether students with newly diagnosed specific learning disability (SpLD) show any abnormalities in cerebral cortex perfusion. Cross-sectional single-arm pilot study in two tertiary care hospitals. Nine students with SpLD were enrolled. Brain SPECT scan was done twice in each student. For the first or "baseline" scan, the student was first made to sit with eyes open in a quiet, dimly lit room for a period of 30-40 min and then injected intravenously with 20 mCi of 99mTc-ECD. An hour later, "baseline scan" was conducted. After a minimum gap of 4 days, a second or "test scan" was conducted, wherein the student performed an age-appropriate curriculum-based test for a period of 30-40 min to activate the areas in central nervous system related to learning before being injected with 20 mCi of 99mTc-ECD. Cerebral cortex perfusion at rest and after activation in each student was compared qualitatively by visual analysis and quantitatively using NeuroGam TM software. Visual analysis showed reduction in regional blood flow in temporoparietal areas in both "baseline" and "test" scans. However, when normalization was attempted and comparison done by Talairach analysis using NeuroGam software, no statistically significant change in regional perfusion in temporoparietal areas was appreciated. Brain SPECT scan may serve as a robust tool to identify changes in regional brain perfusion in students with SpLD.
Chatzidakis, Emmanuel M; Barlas, George; Condilis, Nicolas; Bouramas, Dimos; Anagnostopoulos, Demetrios; Volikas, Zacharias; Simopoulos, Konstantinos
2008-01-01
The aim of this study is to find out the correlation of the ventricular size of the brain, as it is estimated using brain computed tomography (CT) scan indexes in patients with normal pressure hydrocephalus (NPH), to: a) the clinical symptoms, and b) the results of cerebrospinal fluid (CSF) shunting procedures. We looked for any predictive value in the estimation of brain CT scan indexes, in patients as above, in whom a shunt is going to be placed. It is well known that it is very difficult to decide who is going to improve after shunting. We studied 40 cases of patients with the diagnosis "NPH" in whom the ventricular shunts were placed. Every symptom (motor disturbance, deficit of memory, incontinence) was separately evaluated preoperatively. The outcome of shunting was also evaluated and the patients were graded. The following CT scan indexes were estimated from the preoperative CT scans of the brain in every case: the ventricle-brain ratio (VBR), the bi-caudate and bi-frontal ratios, the third ventricle-Sylvian fissure (3V-SF) ratio, and the four largest cortical gyri. The method we have used for statistics is "one way analysis of variance", correlating the CT scan indexes to the symptoms of the patients preoperatively, and the outcome of them postoperatively. The main conclusion is that the size of the lateral ventricles of the brain preoperatively is not correlated to the outcome after CSF shunting surgery, but it is correlated to the symptoms of NPH preoperatively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shibata, Koichi, E-mail: shibatak@suzuka-u.ac.jp; Notohara, Daisuke; Sakai, Takihito
2014-11-01
Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitchedmore » images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A visual evaluation of the spatial resolution using the x-ray test pattern indicated that the resolution was 1.8 lp/mm at the IFP and 1.2 lp/mm at heights of −100 and 100 mm from the IFP. The authors demonstrated that a spatial resolution of 1.2–1.8 lp/mm could be obtained within heights of 200 mm of the IFP. The slice sensitivity varied between 11.1 and 13.8 mm for heights between −50 and 100 mm, and there was no critical change in the slice sensitivity within a height range of 150 mm around the IFP. The phantom results demonstrated that tomosynthesis and long-view images could be reconstructed. Conclusions: PS-TS-F provides tomosynthesis images while using low-cost systems that have no tomographic scanning function, such as tableside-controlled universal R/F systems or universal radiographic systems.« less
A CT and MRI scan to MCNP input conversion program.
Van Riper, Kenneth A
2005-01-01
We describe a new program to read a sequence of tomographic scans and prepare the geometry and material sections of an MCNP input file. Image processing techniques include contrast controls and mapping of grey scales to colour. The user interface provides several tools with which the user can associate a range of image intensities to an MCNP material. Materials are loaded from a library. A separate material assignment can be made to a pixel intensity or range of intensities when that intensity dominates the image boundaries; this material is assigned to all pixels with that intensity contiguous with the boundary. Material fractions are computed in a user-specified voxel grid overlaying the scans. New materials are defined by mixing the library materials using the fractions. The geometry can be written as an MCNP lattice or as individual cells. A combination algorithm can be used to join neighbouring cells with the same material.
Integrating respiratory gating into a megavoltage cone-beam CT system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang Jenghwa; Sillanpaa, Jussi; Ling, Clifton C.
2006-07-15
We have previously described a low-dose megavoltage cone beam computed tomography (MV CBCT) system capable of producing projection image using one beam pulse. In this study, we report on its integration with respiratory gating for gated radiotherapy. The respiratory gating system tracks a reflective marker on the patient's abdomen midway between the xiphoid and umbilicus, and disables radiation delivery when the marker position is outside predefined thresholds. We investigate two strategies for acquiring gated scans. In the continuous rotation-gated acquisition, the linear accelerator (LINAC) is set to the fixed x-ray mode and the gantry makes a 5 min, 360 deg.continuousmore » rotation, during which the gating system turns the radiation beam on and off, resulting in projection images with an uneven distribution of projection angles (e.g., in 70 arcs each covering 2 deg.). In the gated rotation-continuous acquisition, the LINAC is set to the dynamic arc mode, which suspends the gantry rotation when the gating system inhibits the beam, leading to a slightly longer (6-7 min) scan time, but yielding projection images with more evenly distributed projection angles (e.g., {approx}0.8 deg.between two consecutive projection angles). We have tested both data acquisition schemes on stationary (a contrast detail and a thoracic) phantoms and protocol lung patients. For stationary phantoms, a separate motion phantom not visible in the images is used to trigger the RPM system. Frame rate is adjusted so that approximately 450 images (13 MU) are acquired for each scan and three-dimensional tomographic images reconstructed using a Feldkamp filtered backprojection algorithm. The gated rotation-continuous acquisition yield reconstructions free of breathing artifacts. The tumor in parenchymal lung and normal tissues are easily discernible and the boundary between the diaphragm and the lung sharply defined. Contrast-to-noise ratio (CNR) is not degraded relative to nongated scans of stationary phantoms. The continuous rotation-gated acquisition scan also yields tomographic images with discernible anatomic features; however, streak artifacts are observed and CNR is reduced by approximately a factor of 4. In conclusion, we have successfully developed a gated MV CBCT system to verify the patient positioning for gated radiotherapy.« less
ViRPET--combination of virtual reality and PET brain imaging
Majewski, Stanislaw; Brefczynski-Lewis, Julie
2017-05-23
Various methods, systems and apparatus are provided for brain imaging during virtual reality stimulation. In one example, among others, a system for virtual ambulatory environment brain imaging includes a mobile brain imager configured to obtain positron emission tomography (PET) scans of a subject in motion, and a virtual reality (VR) system configured to provide one or more stimuli to the subject during the PET scans. In another example, a method for virtual ambulatory environment brain imaging includes providing stimulation to a subject through a virtual reality (VR) system; and obtaining a positron emission tomography (PET) scan of the subject while moving in response to the stimulation from the VR system. The mobile brain imager can be positioned on the subject with an array of imaging photodetector modules distributed about the head of the subject.
Zhao, Dan; Shen, Ya; Peng, Bin; Haapasalo, Markus
2014-11-01
The aim of this study was to describe the canal shaping properties of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Johnson City, TN), and WaveOne (Dentsply Maillefer) nickel-titanium instruments in mandibular first molars by using micro-computed tomographic (micro-CT) scanning. A total of 36 maxillary first molars with 2 separate mesial canals and 1 distal canal were selected and scanned preoperatively and postoperatively by using micro-CT scanning with a voxel size of 30 μm. Canals were prepared with PTU, PTN, and WaveOne systems under hypochlorite irrigation. The volume of the untreated canal; the volume of dentin removed after preparation; the amount of the uninstrumented area; and the transportation to the coronal, middle, and apical thirds of canals were measured. The preparation time and instrument failure were also recorded. Instrumentation of canals increased their volume and surface area. The distal canals had a significantly higher proportion of unprepared surfaces than mesial canals (P < .05). The PTN system produced less transportation than the WaveOne and PTU systems in the apical third of the mesial canals (P < .05). There was no significant difference on apical transportation in distal canals among the 3 instrument systems. Instrumentation with WaveOne was significantly faster than with the other 2 instruments (P < .05). The PTN, PTU, and WaveOne instruments shaped root canals in mandibular first molars in vitro without significant shaping errors. The curved canals prepared using PTN had less apical transportation than the canals prepared using WaveOne and PTU. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik
2018-02-01
Digital breast tomosynthesis (DBT) is an emerging tool for breast-cancer screening and diagnostics. The purpose of this study is to present a second-generation photon-counting slit-scanning DBT system and compare it to the first-generation system in terms of geometry and image quality. The study presents the first image-quality measurements on the second-generation system. The geometry of the new system is based on a combined rotational and linear motion, in contrast to a purely rotational scan motion in the first generation. In addition, the calibration routines have been updated. Image quality was measured in the center of the image field in terms of in-slice modulation transfer function (MTF), artifact spread function (ASF), and in-slice detective quantum efficiency (DQE). Images were acquired using a W/Al 29 kVp spectrum at 13 mAs with 2 mm Al additional filtration and reconstructed using simple back-projection. The in-slice 50% MTF was improved in the chest-mammilla direction, going from 3.2 to 3.5 lp/mm, and the zero-frequency DQE increased from 0.71 to 0.77. The MTF and ASF were otherwise found to be on par for the two systems. The new system has reduced in-slice variation of the tomographic angle. The new geometry is less curved, which reduces in-slice tomographic-angle variation, and increases the maximum compression height, making the system accessible for a larger population. The improvements in MTF and DQE were attributed to the updated calibration procedures. We conclude that the second-generation system maintains the key features of the photon-counting system while maintaining or improving image quality and improving the maximum compression height. © 2017 American Association of Physicists in Medicine.
Fetal brain volumetry through MRI volumetric reconstruction and segmentation
Estroff, Judy A.; Barnewolt, Carol E.; Connolly, Susan A.; Warfield, Simon K.
2013-01-01
Purpose Fetal MRI volumetry is a useful technique but it is limited by a dependency upon motion-free scans, tedious manual segmentation, and spatial inaccuracy due to thick-slice scans. An image processing pipeline that addresses these limitations was developed and tested. Materials and methods The principal sequences acquired in fetal MRI clinical practice are multiple orthogonal single-shot fast spin echo scans. State-of-the-art image processing techniques were used for inter-slice motion correction and super-resolution reconstruction of high-resolution volumetric images from these scans. The reconstructed volume images were processed with intensity non-uniformity correction and the fetal brain extracted by using supervised automated segmentation. Results Reconstruction, segmentation and volumetry of the fetal brains for a cohort of twenty-five clinically acquired fetal MRI scans was done. Performance metrics for volume reconstruction, segmentation and volumetry were determined by comparing to manual tracings in five randomly chosen cases. Finally, analysis of the fetal brain and parenchymal volumes was performed based on the gestational age of the fetuses. Conclusion The image processing pipeline developed in this study enables volume rendering and accurate fetal brain volumetry by addressing the limitations of current volumetry techniques, which include dependency on motion-free scans, manual segmentation, and inaccurate thick-slice interpolation. PMID:20625848
What difference do brain images make in US criminal trials?
Hardcastle, Valerie Gray; Lamb, Edward
2018-05-09
One of the early concerns regarding the use of neuroscience data in criminal trials is that even if the brain images are ambiguous or inconclusive, they still might influence a jury in virtue of the fact that they appear easy to understand. By appearing visually simple, even though they are really statistically constructed maps with a host of assumptions built into them, a lay jury or a judge might take brain scans to be more reliable or relevant than they actually are. Should courts exclude brain scans for being more prejudicial than probative? Herein, we rehearse a brief history of brain scans admitted into criminal trials in the United States, then describe the results of a recent analysis of appellate court decisions that referenced 1 or more brain scans in the judicial decision. In particular, we aim to explain how courts use neuroscience imaging data: Do they interpret the data correctly? Does it seem that scans play an oversized role in judicial decision-making? And have they changed how criminal defendants are judged? It is our hope that in answering these questions, clinicians and defence attorneys will be able to make better informed decisions regarding about how to manage those incarcerated. © 2018 John Wiley & Sons, Ltd.
Compact photoacoustic tomography system
NASA Astrophysics Data System (ADS)
Kalva, Sandeep Kumar; Pramanik, Manojit
2017-03-01
Photoacoustic tomography (PAT) is a non-ionizing biomedical imaging modality which finds applications in brain imaging, tumor angiogenesis, monitoring of vascularization, breast cancer imaging, monitoring of oxygen saturation levels etc. Typical PAT systems uses Q-switched Nd:YAG laser light illumination, single element large ultrasound transducer (UST) as detector. By holding the UST in horizontal plane and moving it in a circular motion around the sample in full 2π radians photoacoustic data is collected and images are reconstructed. The horizontal positioning of the UST make the scanning radius large, leading to larger water tank and also increases the load on the motor that rotates the UST. To overcome this limitation, we present a compact photoacoustic tomographic (ComPAT) system. In this ComPAT system, instead of holding the UST in horizontal plane, it is held in vertical plane and the photoacoustic waves generated at the sample are detected by the UST after it is reflected at 45° by an acoustic reflector attached to the transducer body. With this we can reduce the water tank size and load on the motor, thus overall PAT system size can be reduced. Here we show that with the ComPAT system nearly similar PA images (phantom and in vivo data) can be obtained as that of the existing PAT systems using both flat and cylindrically focused transducers.
The effects of age on the neural correlates of episodic encoding.
Grady, C L; McIntosh, A R; Rajah, M N; Beig, S; Craik, F I
1999-12-01
Young and old adults underwent positron emission tomographic scans while encoding pictures of objects and words using three encoding strategies: deep processing (a semantic living/nonliving judgement), shallow processing (size judgement) and intentional learning. Picture memory exceeded word memory in both young and old groups, and there was an age-related decrement only in word recognition. During the encoding tasks three brain activity patterns were found that differentiated stimulus type and the different encoding strategies. The stimulus-specific pattern was characterized by greater activity in extrastriate and medial temporal cortices during picture encoding, and greater activity in left prefrontal and temporal cortices during encoding of words. The older adults showed this pattern to a significantly lesser degree. A pattern distinguishing deep processing from intentional learning of words and pictures was identified, characterized mainly by differences in prefrontal cortex, and this pattern also was of significantly lesser magnitude in the old group. A final pattern identified areas with increased activity during deep processing and intentional learning of pictures, including left prefrontal and bilateral medial temporal regions. There was no group difference in this pattern. These results indicate age-related dysfunction in several encoding networks, with sparing of one specifically involved in more elaborate encoding of pictures. These age-related changes appear to affect verbal memory more than picture memory.
NASA Astrophysics Data System (ADS)
Maurer, Calvin R., Jr.; Sauer, Frank; Hu, Bo; Bascle, Benedicte; Geiger, Bernhard; Wenzel, Fabian; Recchi, Filippo; Rohlfing, Torsten; Brown, Christopher R.; Bakos, Robert J.; Maciunas, Robert J.; Bani-Hashemi, Ali R.
2001-05-01
We are developing a video see-through head-mounted display (HMD) augmented reality (AR) system for image-guided neurosurgical planning and navigation. The surgeon wears a HMD that presents him with the augmented stereo view. The HMD is custom fitted with two miniature color video cameras that capture a stereo view of the real-world scene. We are concentrating specifically at this point on cranial neurosurgery, so the images will be of the patient's head. A third video camera, operating in the near infrared, is also attached to the HMD and is used for head tracking. The pose (i.e., position and orientation) of the HMD is used to determine where to overlay anatomic structures segmented from preoperative tomographic images (e.g., CT, MR) on the intraoperative video images. Two SGI 540 Visual Workstation computers process the three video streams and render the augmented stereo views for display on the HMD. The AR system operates in real time at 30 frames/sec with a temporal latency of about three frames (100 ms) and zero relative lag between the virtual objects and the real-world scene. For an initial evaluation of the system, we created AR images using a head phantom with actual internal anatomic structures (segmented from CT and MR scans of a patient) realistically positioned inside the phantom. When using shaded renderings, many users had difficulty appreciating overlaid brain structures as being inside the head. When using wire frames, and texture-mapped dot patterns, most users correctly visualized brain anatomy as being internal and could generally appreciate spatial relationships among various objects. The 3D perception of these structures is based on both stereoscopic depth cues and kinetic depth cues, with the user looking at the head phantom from varying positions. The perception of the augmented visualization is natural and convincing. The brain structures appear rigidly anchored in the head, manifesting little or no apparent swimming or jitter. The initial evaluation of the system is encouraging, and we believe that AR visualization might become an important tool for image-guided neurosurgical planning and navigation.
A simple anaesthetic and monitoring system for magnetic resonance imaging.
Rejger, V S; Cohn, B F; Vielvoye, G J; de Raadt, F B
1989-09-01
Clinical magnetic resonance imaging (MRI) is a digital tomographic technique which utilizes radio waves emitted by hydrogen protons in a powerful magnetic field to form an image of soft-tissue structures and abnormalities within the body. Unfortunately, because of the relatively long scanning time required and the narrow deep confines of the MRI tunnel and Faraday cage, some patients cannot be examined without the use of heavy sedation or general anaesthesia. Due to poor access to the patient and the strong magnetic field, several problems arise in monitoring and administering anaesthesia during this procedure. In this presentation these problems and their solutions, as resolved by our institution, are discussed. Of particular interest is the anaesthesia circuit specifically adapted for use during MRI scanning.
Traumatic Brain Injury: A Guide for Caregivers of Service Members and Veterans. Caregivers Companion
2010-04-01
legs , body, speech, or eye movements. Axons – Also known as nerve fibers, an axon is a long, slender projection of a nerve...excessively nasal; volume may be weak; drooling may occur. Dyskinesia – Involuntary movements most often seen in the arms or legs . Electroencephalograph, or...Tests may include: CT Scan, MRI, Angiogram, EEG, SPECT Scan, PET Scan, DTI Scan. Neurotransmitters – Chemicals found within the brain that
Tomographic Small-Animal Imaging Using a High-Resolution Semiconductor Camera
Kastis, GA; Wu, MC; Balzer, SJ; Wilson, DW; Furenlid, LR; Stevenson, G; Barber, HB; Barrett, HH; Woolfenden, JM; Kelly, P; Appleby, M
2015-01-01
We have developed a high-resolution, compact semiconductor camera for nuclear medicine applications. The modular unit has been used to obtain tomographic images of phantoms and mice. The system consists of a 64 x 64 CdZnTe detector array and a parallel-hole tungsten collimator mounted inside a 17 cm x 5.3 cm x 3.7 cm tungsten-aluminum housing. The detector is a 2.5 cm x 2.5 cm x 0.15 cm slab of CdZnTe connected to a 64 x 64 multiplexer readout via indium-bump bonding. The collimator is 7 mm thick, with a 0.38 mm pitch that matches the detector pixel pitch. We obtained a series of projections by rotating the object in front of the camera. The axis of rotation was vertical and about 1.5 cm away from the collimator face. Mouse holders were made out of acrylic plastic tubing to facilitate rotation and the administration of gas anesthetic. Acquisition times were varied from 60 sec to 90 sec per image for a total of 60 projections at an equal spacing of 6 degrees between projections. We present tomographic images of a line phantom and mouse bone scan and assess the properties of the system. The reconstructed images demonstrate spatial resolution on the order of 1–2 mm. PMID:26568676
Giga-pixel lensfree holographic microscopy and tomography using color image sensors.
Isikman, Serhan O; Greenbaum, Alon; Luo, Wei; Coskun, Ahmet F; Ozcan, Aydogan
2012-01-01
We report Giga-pixel lensfree holographic microscopy and tomography using color sensor-arrays such as CMOS imagers that exhibit Bayer color filter patterns. Without physically removing these color filters coated on the sensor chip, we synthesize pixel super-resolved lensfree holograms, which are then reconstructed to achieve ~350 nm lateral resolution, corresponding to a numerical aperture of ~0.8, across a field-of-view of ~20.5 mm(2). This constitutes a digital image with ~0.7 Billion effective pixels in both amplitude and phase channels (i.e., ~1.4 Giga-pixels total). Furthermore, by changing the illumination angle (e.g., ± 50°) and scanning a partially-coherent light source across two orthogonal axes, super-resolved images of the same specimen from different viewing angles are created, which are then digitally combined to synthesize tomographic images of the object. Using this dual-axis lensfree tomographic imager running on a color sensor-chip, we achieve a 3D spatial resolution of ~0.35 µm × 0.35 µm × ~2 µm, in x, y and z, respectively, creating an effective voxel size of ~0.03 µm(3) across a sample volume of ~5 mm(3), which is equivalent to >150 Billion voxels. We demonstrate the proof-of-concept of this lensfree optical tomographic microscopy platform on a color CMOS image sensor by creating tomograms of micro-particles as well as a wild-type C. elegans nematode.
Tomographic brain imaging with nucleolar detail and automatic cell counting
NASA Astrophysics Data System (ADS)
Hieber, Simone E.; Bikis, Christos; Khimchenko, Anna; Schweighauser, Gabriel; Hench, Jürgen; Chicherova, Natalia; Schulz, Georg; Müller, Bert
2016-09-01
Brain tissue evaluation is essential for gaining in-depth insight into its diseases and disorders. Imaging the human brain in three dimensions has always been a challenge on the cell level. In vivo methods lack spatial resolution, and optical microscopy has a limited penetration depth. Herein, we show that hard X-ray phase tomography can visualise a volume of up to 43 mm3 of human post mortem or biopsy brain samples, by demonstrating the method on the cerebellum. We automatically identified 5,000 Purkinje cells with an error of less than 5% at their layer and determined the local surface density to 165 cells per mm2 on average. Moreover, we highlight that three-dimensional data allows for the segmentation of sub-cellular structures, including dendritic tree and Purkinje cell nucleoli, without dedicated staining. The method suggests that automatic cell feature quantification of human tissues is feasible in phase tomograms obtained with isotropic resolution in a label-free manner.
[Fetal neurosonography using 3-dimensional multiplanar sonography].
Chaoui, R; Heling, K S; Kainer, F; Karl, K
2012-04-01
This review focuses on the examination of the fetal brain, using three-dimensional (3D) ultrasound and the multiplanar rendering mode (MPR). The routine examination of the brain is achieved with axial planes but a dedicated fetal neurosonogram requires additional coronal and sagittal views, in order to provide a complete view of the different brain structures. Because these planes are difficult to obtain under many conditions, the present paper shows how 3D MPR allows one to obtain 1 or multiple reconstructed images from a digital volume. The display can be either as orthogonal planes, tomographic planes with parallel slices or as one single plane of the region of interest, which can be selected by the examiner. This approach allows easily the demonstration of the corpus callosum, the cerebellar vermis, the three-horn view, the foetal hippocampus and other regions. In addition, early neurosonography of the developing brain from the 7th week of pregnancy onwards can be achieved. © Georg Thieme Verlag KG Stuttgart · New York.
Bayesian estimation of optical properties of the human head via 3D structural MRI
NASA Astrophysics Data System (ADS)
Barnett, Alexander H.; Culver, Joseph P.; Sorensen, A. Gregory; Dale, Anders M.; Boas, David A.
2003-10-01
Knowledge of the baseline optical properties of the tissues of the human head is essential for absolute cerebral oximetry, and for quantitative studies of brain activation. In this work we numerically model the utility of signals from a small 6-optode time-resolved diffuse optical tomographic apparatus for inferring baseline scattering and absorption coefficients of the scalp, skull and brain, when complete geometric information is available from magnetic resonance imaging (MRI). We use an optical model where MRI-segmented tissues are assumed homogeneous. We introduce a noise model capturing both photon shot noise and forward model numerical accuracy, and use Bayesian inference to predict errorbars and correlations on the measurments. We also sample from the full posterior distribution using Markov chain Monte Carlo. We conclude that ~ 106 detected photons are sufficient to measure the brain"s scattering and absorption to a few percent. We present preliminary results using a fast multi-layer slab model, comparing the case when layer thicknesses are known versus unknown.
Imaging fast electrical activity in the brain with electrical impedance tomography
Aristovich, Kirill Y.; Packham, Brett C.; Koo, Hwan; Santos, Gustavo Sato dos; McEvoy, Andy; Holder, David S.
2016-01-01
Imaging of neuronal depolarization in the brain is a major goal in neuroscience, but no technique currently exists that could image neural activity over milliseconds throughout the whole brain. Electrical impedance tomography (EIT) is an emerging medical imaging technique which can produce tomographic images of impedance changes with non-invasive surface electrodes. We report EIT imaging of impedance changes in rat somatosensory cerebral cortex with a resolution of 2 ms and < 200 μm during evoked potentials using epicortical arrays with 30 electrodes. Images were validated with local field potential recordings and current source-sink density analysis. Our results demonstrate that EIT can image neural activity in a volume 7 × 5 × 2 mm in somatosensory cerebral cortex with reduced invasiveness, greater resolution and imaging volume than other methods. Modeling indicates similar resolutions are feasible throughout the entire brain so this technique, uniquely, has the potential to image functional connectivity of cortical and subcortical structures. PMID:26348559
Quantitative multiphoton imaging
NASA Astrophysics Data System (ADS)
König, Karsten; Weinigel, Martin; Breunig, Hans Georg; Uchugonova, Aisada
2014-02-01
Certified clinical multiphoton tomographs for label-free multidimensional high-resolution in vivo imaging have been introduced to the market several years ago. Novel tomographs include a flexible 360° scan head attached to a mechanooptical arm for autofluorescence and SHG imaging as well as a CARS module. Non-fluorescent lipids and water, mitochondrial fluorescent NAD(P)H, fluorescent elastin, keratin, and melanin as well as SHG-active collagen can be imaged in vivo with submicron resolution in human skin. Sensitive and rapid detectors allow single photon counting and the construction of 3D maps where the number of detected photons per voxel is depicted. Intratissue concentration profiles from endogenous as well exogenous substances can be generated when the number of detected photons can be correlated with the number of molecules with respect to binding and scattering behavior. Furthermore, the skin ageing index SAAID based on the ratio elastin/collagen as well as the epidermis depth based on the onset of SHG generation can be determined.
Paraneoplastic neurologic syndrome and autoimmune Addison disease in a patient with thymoma.
Morita, Hiroyuki; Hirota, Takuo; Mune, Tomoatsu; Suwa, Tetsuya; Ishizuka, Tatsuo; Inuzuka, Takashi; Tanaka, Keiko; Ishimori, Masatoshi; Nakamura, Shigenori; Yasuda, Keigo
2005-01-01
A 48-year-old man with autoimmune Addison disease developed the following paraneoplastic neurologic syndromes (PNNS): limbic encephalitis, opsoclonus/myoclonus, and sensorimotor and autonomic neuropathies. An anterior mediastinal mass detected on a chest computed tomographic scan was found on resection to be a noninvasive lymphocytic thymoma. The PNNS went into remission 1 year after the thymectomy. This is the first case of thymoma associated with autoimmune Addison disease and PNNS to be described in the literature.
Fluorescence lifetime imaging of induced pluripotent stem cells
NASA Astrophysics Data System (ADS)
Uchugonova, Aisada; Batista, Ana; König, Karsten
2014-02-01
The multiphoton FLIM tomograph MPTflex with its flexible scan head, articulated arm, and the tunable femtosecond laser source was employed to study cell monolayers and 3D cell clusters. FLIM was performed with 250 ps temporal resolution and submicron special resolution using time-correlated single photon counting. The autofluorescence based on NAD(P)H and flavins/flavoproteins has been measured in mouse embryonic fibroblasts, induced pluripotent stem cells (iPS cells) originated from mouse embryonic fibroblasts and non-proliferative mouse embryonic fibroblasts.
Three Dimensional Assembly in Directed Self-assembly of Block Copolymers
Segal-Peretz, Tamar; Zhou, Chun; Ren, Jiaxing; ...
2016-09-02
The three-dimensional assembly of poly (styrene-b-methyl methacrylate) (PS-b-PMMA) in chemoepitaxy and graphoepitaxy directed self-assembly (DSA) was investigated using scanning transmission electron microscopy (STEM) tomography. The tomographic characterization revealed hidden morphologies and defects at the BCP- chemical pattern interface in lamellar DSA, and probed the formation of cylinders at the bottom of cylindrical DSA for contact hole shrink. Lastly, future work will include control over 3D assembly in sub-10 nm processes.
Corkscrew basilar artery as an incidental finding on neuroimaging.
Moser, Franklin G; Sarnat, Harvey B; Maya, Marcel M; Menkes, John H
2007-11-01
We report on an incidental finding of a markedly tortuous basilar artery in a 6-year-old child. The child underwent a computed tomography scan for minor head trauma, and a basilar artery abnormality was discovered, i.e., a markedly tortuous basilar artery without any other congenital anomalies or syndromes. After an exhaustive workup including computed tomography, magnetic resonance imaging, magnetic resonance angiography, computed tomographic angiography, and genetic tests for associated genetic syndromes, no intervention was deemed necessary. The embryonic etiology and clinical implications are discussed.
Pearce, Mark S; Salotti, Jane A; Little, Mark P; McHugh, Kieran; Lee, Choonsik; Kim, Kwang Pyo; Howe, Nicola L; Ronckers, Cecile M; Rajaraman, Preetha; Craft, Alan W; Parker, Louise; de González, Amy Berrington
2012-01-01
Summary Background Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. Methods In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. Findings During follow-up, 74 of 178 604 patients were diagnosed with leukaemia and 135 of 176 587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005–0·120; p=0·0097) and brain tumours (0·023, 0·010–0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46–6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50–74 mGy (mean dose 60·42 mGy) was 2·82 (1·33–6·03). Interpretation Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10 000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. Funding US National Cancer Institute and UK Department of Health. PMID:22681860
Pearce, Mark S; Salotti, Jane A; Little, Mark P; McHugh, Kieran; Lee, Choonsik; Kim, Kwang Pyo; Howe, Nicola L; Ronckers, Cecile M; Rajaraman, Preetha; Sir Craft, Alan W; Parker, Louise; Berrington de González, Amy
2012-08-04
Although CT scans are very useful clinically, potential cancer risks exist from associated ionising radiation, in particular for children who are more radiosensitive than adults. We aimed to assess the excess risk of leukaemia and brain tumours after CT scans in a cohort of children and young adults. In our retrospective cohort study, we included patients without previous cancer diagnoses who were first examined with CT in National Health Service (NHS) centres in England, Wales, or Scotland (Great Britain) between 1985 and 2002, when they were younger than 22 years of age. We obtained data for cancer incidence, mortality, and loss to follow-up from the NHS Central Registry from Jan 1, 1985, to Dec 31, 2008. We estimated absorbed brain and red bone marrow doses per CT scan in mGy and assessed excess incidence of leukaemia and brain tumours cancer with Poisson relative risk models. To avoid inclusion of CT scans related to cancer diagnosis, follow-up for leukaemia began 2 years after the first CT and for brain tumours 5 years after the first CT. During follow-up, 74 of 178,604 patients were diagnosed with leukaemia and 135 of 176,587 patients were diagnosed with brain tumours. We noted a positive association between radiation dose from CT scans and leukaemia (excess relative risk [ERR] per mGy 0·036, 95% CI 0·005-0·120; p=0·0097) and brain tumours (0·023, 0·010-0·049; p<0·0001). Compared with patients who received a dose of less than 5 mGy, the relative risk of leukaemia for patients who received a cumulative dose of at least 30 mGy (mean dose 51·13 mGy) was 3·18 (95% CI 1·46-6·94) and the relative risk of brain cancer for patients who received a cumulative dose of 50-74 mGy (mean dose 60·42 mGy) was 2·82 (1·33-6·03). Use of CT scans in children to deliver cumulative doses of about 50 mGy might almost triple the risk of leukaemia and doses of about 60 mGy might triple the risk of brain cancer. Because these cancers are relatively rare, the cumulative absolute risks are small: in the 10 years after the first scan for patients younger than 10 years, one excess case of leukaemia and one excess case of brain tumour per 10,000 head CT scans is estimated to occur. Nevertheless, although clinical benefits should outweigh the small absolute risks, radiation doses from CT scans ought to be kept as low as possible and alternative procedures, which do not involve ionising radiation, should be considered if appropriate. US National Cancer Institute and UK Department of Health. Copyright © 2012 Elsevier Ltd. All rights reserved.
Automated three-dimensional quantification of myocardial perfusion and brain SPECT.
Slomka, P J; Radau, P; Hurwitz, G A; Dey, D
2001-01-01
To allow automated and objective reading of nuclear medicine tomography, we have developed a set of tools for clinical analysis of myocardial perfusion tomography (PERFIT) and Brain SPECT/PET (BRASS). We exploit algorithms for image registration and use three-dimensional (3D) "normal models" for individual patient comparisons to composite datasets on a "voxel-by-voxel basis" in order to automatically determine the statistically significant abnormalities. A multistage, 3D iterative inter-subject registration of patient images to normal templates is applied, including automated masking of the external activity before final fit. In separate projects, the software has been applied to the analysis of myocardial perfusion SPECT, as well as brain SPECT and PET data. Automatic reading was consistent with visual analysis; it can be applied to the whole spectrum of clinical images, and aid physicians in the daily interpretation of tomographic nuclear medicine images.
Low dose tomographic fluoroscopy: 4D intervention guidance with running prior
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flach, Barbara; Kuntz, Jan; Brehm, Marcus
Purpose: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time ofmore » an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention.Methods: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry.Results: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position.Conclusions: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.« less
What is Aphasia? | NIH MedlinePlus the Magazine
... of aphasia while treating the patient for a brain injury. To diagnose aphasia, the clinician will usually order ... a computed tomography (CT) scan to locate a brain injury. In addition to the scans, the clinician usually ...
Thomson, Daniel U; Wileman, Benjamin W; Rezac, Darrel J; Miesner, Matt D; Johnson-Neitman, Jennifer L; Biller, David S
2013-11-01
To evaluate with CT the efficacy of various combinations of firearms and ammunitions to penetrate and disrupt the brain tissue of cadaveric heads of feedlot steers. 42 fresh cadaveric heads of 12- to 18-month-old Bos taurus steers. For each of 7 combinations of firearms and ammunitions (.22-caliber rifle firing a long rifle 30-grain plated lead solid- or hollow-point round, .223-caliber carbine firing a 50-grain ballistic-tip round, 9-mm pistol firing a 124-grain total metal jacket round, .45-caliber automatic Colt pistol [ACP] firing a 230-grain full metal jacket round, and 12-gauge shotgun firing a 2.75-inch 1.25-ounce No. 4 birdshot shell or a 1-ounce rifled slug), 6 cadaveric heads were shot at an identical distance (3 m), angle, and anatomic location. Heads were scanned with third-generation CT, and images were evaluated to determine extent of penetration, projectile fragmentation, cranial fracture, and likelihood of instantaneous death (≥ 30% destruction of brain tissue or a brainstem lesion). RESULTS-41 of 42 skulls were penetrated by the projectile. Instantaneous death was considered a likely consequence for 83% (25/30) of heads shot with a rifle-fired .22-caliber solid-point round, pistol-fired .45-caliber ACP round, carbine-fired .223-caliber round, and shotgun-fired birdshot and slug. Of the 18 heads shot with pistol-fired 9-mm and .45-caliber ACP rounds and rifle-fired .22-caliber hollow-point rounds, only 6 had brainstem lesions. CONCLUSIONS AND CLINICAL RELEVANCE-Results suggested that gunshots delivered by all firearm-ammunition combinations except rifle-fired .22-caliber hollow-point rounds and pistol-fired 9-mm rounds were viable options for euthanasia of feedlot cattle.
Experimental acute thrombotic stroke in baboons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Del Zoppo, G.J.; Copeland, B.R.; Harker, L.A.
1986-11-01
To study the effects of antithrombotic therapy in experimental stroke, we have characterized a baboon model of acute cerebrovascular thrombosis. In this model an inflatable silastic balloon cuff has been implanted by transorbital approach around the right middle cerebral artery (MCA), proximal to the take-off of the lenticulostriate arteries (LSA). Inflation of the balloon for 3 hours in six animals produced a stereotypic sustained stroke syndrome characterized by contralateral hemiparesis. An infarction volume of 3.2 +/- 1.5 cm3 in the ipsilateral corpus striatum was documented by computerized tomographic (CT) scanning at 10 days following stroke induction and 3.9 +/- 1.9more » cm3 (n = 4) at 14 days by morphometric neuropathologic determinations of brain specimens fixed in situ by pressure-perfusion with 10% buffered formalin. Immediate pressure-perfusion fixation following deflation of the balloon was performed in 16 additional animals given Evans blue dye intravenously prior to the 3 hour MCA balloon occlusion. Light microscopy and transmission electron microscopy consistently confirmed the presence of thrombotic material occluding microcirculatory branches of the right LSA in the region of Evans blue stain, but not those of the contralateral corpus striatum. When autologous 111In-platelets were infused intravenously in four animals from the above group prior to the transient 3 hour occlusion of the right MCA, gamma scintillation camera imaging of each perfused-fixed whole brain demonstrated the presence of a single residual focus of 111In-platelet activity involving only the Evans blue-stained right corpus striatum. Focal right hemispheric activity was equivalent to 0.55 +/- 0.49 ml of whole blood, and the occlusion score derived from histologic examination of the microcirculation of the Evans blue-stained corpus striatum averaged 34.8 +/- 2.8.« less
Dimopoulou, Ioanna; Tsagarakis, Stylianos; Theodorakopoulou, Maria; Douka, Evangelia; Zervou, Maria; Kouyialis, Andreas T; Thalassinos, Nikolaos; Roussos, Charis
2004-06-01
To investigate the incidence and type of endocrine abnormalities in critical care patients with traumatic brain injury (TBI) and to examine their relationships to possible predisposing factors. Prospective study. General intensive care unit in a university hospital. Thirty-four TBI patients (27 men, 7 women), having a mean age of 37+/-16 years, were studied after weaning from mechanical ventilation. Baseline endocrine assessment was carried out by measuring cortisol, corticotropin, dehydroepiandrosterone sulfate, free thyroxine, thyrotropin (TSH), testosterone, oestradiol, follicle stimulating hormone (FSH), luteinizing hormone, prolactin, growth hormone and insulin-like growth factor I. Dynamic evaluation was performed by human corticotropin releasing hormone and growth hormone releasing hormone in all patients. Male patients underwent additional investigation with gonadotropin-releasing hormone. Severity of neurological derangement was graded according to Glasgow Coma Scale (GCS), Marshall Computerized Tomographic Classification and intracranial pressure (ICP) levels. Eighteen of the 34 patients (53%) had an abnormal result in at least one hormonal axis tested, with cortisol hyporesponsiveness and gonadal dysfunction being equally common, affecting 24% of patients. Endocrine abnormalities were associated with a higher brain CT-scan classification score ( p=0.02). The GCS on admission correlated positively with baseline FSH (r=0.37, p=0.03), peak FSH (r=0.41, p=0.03), testosterone (r=0.44, p=0.02) and TSH (r=0.39, p=0.03). There were no relations between ICP(max) and any baseline or dynamic hormone measurements. Patients with TBI receiving critical care show changes in their neuroendocrine responses, which depend upon clinical and radiological measures of head injury severity. Most common abnormalities include cortisol hyporesponsiveness and hypogonadism.
Intraoperative Secondary Insults During Orthopedic Surgery in Traumatic Brain Injury.
Algarra, Nelson N; Lele, Abhijit V; Prathep, Sumidtra; Souter, Michael J; Vavilala, Monica S; Qiu, Qian; Sharma, Deepak
2017-07-01
Secondary insults worsen outcomes after traumatic brain injury (TBI). However, data on intraoperative secondary insults are sparse. The primary aim of this study was to examine the prevalence of intraoperative secondary insults during orthopedic surgery after moderate-severe TBI. We also examined the impact of intraoperative secondary insults on postoperative head computed tomographic scan, intracranial pressure (ICP), and escalation of care within 24 hours of surgery. We reviewed medical records of TBI patients 18 years and above with Glasgow Coma Scale score <13 who underwent single orthopedic surgery within 2 weeks of TBI. Secondary insults examined were: systemic hypotension (systolic blood pressure<90 mm Hg), intracranial hypertension (ICP>20 mm Hg), cerebral hypotension (cerebral perfusion pressure<50 mm Hg), hypercarbia (end-tidal CO2>40 mm Hg), hypocarbia (end-tidal CO2<30 mm Hg in absence of intracranial hypertension), hyperglycemia (glucose>200 mg/dL), hypoglycemia (glucose<60 mg/dL), and hyperthermia (temperature >38°C). A total of 78 patients (41 [18 to 81] y, 68% male) met the inclusion criteria. The most common intraoperative secondary insults were systemic hypotension (60%), intracranial hypertension and cerebral hypotension (50% and 45%, respectively, in patients with ICP monitoring), hypercarbia (32%), and hypocarbia (29%). Intraoperative secondary insults were associated with worsening of head computed tomography, postoperative decrease of Glasgow Coma Scale score by ≥2, and escalation of care. After Bonferroni correction, association between cerebral hypotension and postoperative escalation of care remained significant (P<0.001). Intraoperative secondary insults were common during orthopedic surgery in patients with TBI and were associated with postoperative escalation of care. Strategies to minimize intraoperative secondary insults are needed.
Saijo, Takeaki; Maeda, Jun; Okauchi, Takashi; Maeda, Jun-ichi; Morio, Yasunori; Kuwahara, Yasuhiro; Suzuki, Masayuki; Goto, Nobuharu; Fukumura, Toshimitsu; Suhara, Tetsuya; Higuchi, Makoto
2012-01-01
A novel investigational antidepressant with high affinity for the serotonin transporter and the serotonin 1A (5-HT(1A)) receptor, called Wf-516 (structural formula: (2S)-1-[4-(3,4-dichlorophenyl)piperidin-1-yl]-3-[2-(5-methyl-1,3,4-oxadiazol-2-yl)benzo[b]furan-4-yloxy]propan-2-ol monohydrochloride), has been found to exert a rapid therapeutic effect, although the mechanistic basis for this potential advantage remains undetermined. We comparatively investigated the pharmacokinetics and pharmacodynamics of Wf-516 and pindolol by positron emission tomographic (PET) and autoradiographic assays of rat brains in order to elucidate their molecular interactions with presynaptic and postsynaptic 5-HT(1A) receptors. In contrast to the full receptor occupancy by pindolol in PET measurements, the binding of Wf-516 to 5-HT(1A) receptors displayed limited capacity, with relatively high receptor occupancy being achieved in regions predominantly containing presynaptic receptors. This selectivity was further proven by PET scans of neurotoxicant-treated rats deficient in presynaptic 5-HT(1A) receptors. In addition, [(35)S]guanosine 5'-O-[γ-thio]triphosphate autoradiography indicated a partial agonistic ability of Wf-516 for 5-HT(1A) receptors. This finding has lent support to reports that diverse partial agonists for 5-HT(1A) receptors exert high sensitivity for presynaptic components. Thus, the present PET data suggest a relatively high capacity of presynaptic binding sites for partial agonists. Since our in vitro and ex vivo autoradiographies failed to illustrate these distinct features of Wf-516, in vivo PET imaging is considered to be, thus far, the sole method capable of pharmacokinetically demonstrating the unique actions of Wf-516 and similar new-generation antidepressants.
Okauchi, Takashi; Maeda, Jun-ichi; Morio, Yasunori; Kuwahara, Yasuhiro; Suzuki, Masayuki; Goto, Nobuharu; Fukumura, Toshimitsu; Suhara, Tetsuya; Higuchi, Makoto
2012-01-01
A novel investigational antidepressant with high affinity for the serotonin transporter and the serotonin 1A (5-HT1A) receptor, called Wf-516 (structural formula: (2S)-1-[4-(3,4-dichlorophenyl)piperidin-1-yl]-3-[2-(5-methyl-1,3,4-oxadiazol-2-yl)benzo[b]furan-4-yloxy]propan-2-ol monohydrochloride), has been found to exert a rapid therapeutic effect, although the mechanistic basis for this potential advantage remains undetermined. We comparatively investigated the pharmacokinetics and pharmacodynamics of Wf-516 and pindolol by positron emission tomographic (PET) and autoradiographic assays of rat brains in order to elucidate their molecular interactions with presynaptic and postsynaptic 5-HT1A receptors. In contrast to the full receptor occupancy by pindolol in PET measurements, the binding of Wf-516 to 5-HT1A receptors displayed limited capacity, with relatively high receptor occupancy being achieved in regions predominantly containing presynaptic receptors. This selectivity was further proven by PET scans of neurotoxicant-treated rats deficient in presynaptic 5-HT1A receptors. In addition, [35S]guanosine 5′-O-[γ-thio]triphosphate autoradiography indicated a partial agonistic ability of Wf-516 for 5-HT1A receptors. This finding has lent support to reports that diverse partial agonists for 5-HT1A receptors exert high sensitivity for presynaptic components. Thus, the present PET data suggest a relatively high capacity of presynaptic binding sites for partial agonists. Since our in vitro and ex vivo autoradiographies failed to illustrate these distinct features of Wf-516, in vivo PET imaging is considered to be, thus far, the sole method capable of pharmacokinetically demonstrating the unique actions of Wf-516 and similar new-generation antidepressants. PMID:22880045
Dedicated mobile volumetric cone-beam computed tomography for human brain imaging: A phantom study.
Ryu, Jong-Hyun; Kim, Tae-Hoon; Jeong, Chang-Won; Jun, Hong-Young; Heo, Dong-Woon; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha
2015-01-01
Mobile computed tomography (CT) with a cone-beam source is increasingly used in the clinical field. Mobile cone-beam CT (CBCT) has great merits; however, its clinical utility for brain imaging has been limited due to problems including scan time and image quality. The aim of this study was to develop a dedicated mobile volumetric CBCT for obtaining brain images, and to optimize the imaging protocol using a brain phantom. The mobile volumetric CBCT system was evaluated with regards to scan time and image quality, measured as signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), spatial resolution (10% MTF), and effective dose. Brain images were obtained using a CT phantom. The CT scan took 5.14 s at 360 projection views. SNR and CNR were 5.67 and 14.5 at 120 kV/10 mA. SNR and CNR values showed slight improvement as the x-ray voltage and current increased (p < 0.001). Effective dose and 10% MTF were 0.92 mSv and 360 μ m at 120 kV/10 mA. Various intracranial structures were clearly visible in the brain phantom images. Using this CBCT under optimal imaging acquisition conditions, it is possible to obtain human brain images with low radiation dose, reproducible image quality, and fast scan time.
Guo, Yi; Lebel, R Marc; Zhu, Yinghua; Lingala, Sajan Goud; Shiroishi, Mark S; Law, Meng; Nayak, Krishna
2016-05-01
To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm(3), FOV 22 × 22 × 4.2 cm(3), and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm(3), and broader coverage 22 × 22 × 19 cm(3). Temporal resolution was 5 s for both protocols. Time-resolved images and blood-brain barrier permeability maps were qualitatively evaluated by two radiologists. The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.
Resting-state functional connectivity assessed with two diffuse optical tomographic systems.
Niu, Haijing; Khadka, Sabin; Tian, Fenghua; Lin, Zi-Jing; Lu, Chunming; Zhu, Chaozhe; Liu, Hanli
2011-04-01
Functional near-infrared spectroscopy (fNIRS) is recently utilized as a new approach to assess resting-state functional connectivity (RSFC) in the human brain. For any new technique or new methodology, it is necessary to be able to replicate similar experiments using different instruments in order to establish its liability and reproducibility. We apply two different diffuse optical tomographic (DOT) systems (i.e., DYNOT and CW5), with various probe arrangements to evaluate RSFC in the sensorimotor cortex by utilizing a previously published experimental protocol and seed-based correlation analysis. Our results exhibit similar spatial patterns and strengths in RSFC between the bilateral motor cortexes. The consistent observations are obtained from both DYNOT and CW5 systems, and are also in good agreement with the previous fNIRS study. Overall, we demonstrate that the fNIRS-based RSFC is reproducible by various DOT imaging systems among different research groups, enhancing the confidence of neuroscience researchers and clinicians to utilize fNIRS for future applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bourassa, Daisy; Gleber, Sophie-Charlotte; Vogt, Stefan
2016-01-01
Transition metals such as zinc, copper, and iron play key roles in cellular proliferation, cell differentiation, growth, and development. Over the past decade, advances in synchrotron X-ray fluorescence instrumentation presented new opportunities for the three-dimensional mapping of trace metal distributions within intact specimens. Taking advantage of microXRF tomography, we visualized the 3D distribution of zinc and iron in a zebrafish embryo at the onset of the hatching period. The reconstructed volumetric data revealed distinct differences in the elemental distributions, with zinc predominantly localized to the yolk and yolk extension, and iron to various regions of the brain as well asmore » the myotome extending along the dorsal side of the embryo. The data set complements an earlier tomographic study of an embryo at the pharyngula stage (24 hpf), thus offering new insights into the trace metal distribution at key stages of embryonic development.« less
Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT.
Yamakami, I; Yamaura, A; Isobe, K
1993-01-01
To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99mtechnetium-hexamethyl propyleneamine oxime. Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient.
Study of the development of fetal baboon brain using magnetic resonance imaging at 3 Tesla
Liu, Feng; Garland, Marianne; Duan, Yunsuo; Stark, Raymond I.; Xu, Dongrong; Dong, Zhengchao; Bansal, Ravi; Peterson, Bradley S.; Kangarlu, Alayar
2008-01-01
Direct observational data on the development of the brains of human and nonhuman primates is on remarkably scant, and most of our understanding of primate brain development is extrapolated from findings in rodent models. Magnetic resonance imaging (MRI) is a promising tool for the noninvasive, longitudinal study of the developing primate brain. We devised a protocol to scan pregnant baboons serially at 3 T for up to 3 h per session. Seven baboons were scanned 1–6 times, beginning as early as 56 days post-conceptional age, and as late as 185 days (term ~185 days). Successful scanning of the fetal baboon required careful animal preparation and anesthesia, in addition to optimization of the scanning protocol. We successfully acquired maps of relaxation times (T1 and T2) and high-resolution anatomical images of the brains of fetal baboons at multiple time points during the course of gestation. These images demonstrated the convergence of gray and white matter contrast near term, and furthermore demonstrated that the loss of contrast at that age is a consequence of the continuous change in relaxation times during fetal brain development. These data furthermore demonstrate that maps of relaxation times have clear advantages over the relaxation time weighted images for the tracking of the changes in brain structure during fetal development. This protocol for in utero MRI of fetal baboon brains will help to advance the use of nonhuman primate models to study fetal brain development longitudinally. PMID:18155925
Gutierre, R C; Vannucci Campos, D; Mortara, R A; Coppi, A A; Arida, R M
2017-04-01
Confocal laser-scanning microscopy is a useful tool for visualizing neurons and glia in transparent preparations of brain tissue from laboratory animals. Currently, imaging capillaries and venules in transparent brain tissues requires the use of fluorescent proteins. Here, we show that vessels can be imaged by confocal laser-scanning microscopy in transparent cortical, hippocampal and cerebellar preparations after clarification of China ink-injected specimens by the Spalteholz method. This method may be suitable for global, three-dimensional, quantitative analyses of vessels, including stereological estimations of total volume and length and of surface area of vessels, which constitute indirect approaches to investigate angiogenesis. © 2017 Anatomical Society.
Clinical safety of 3-T brain magnetic resonance imaging in newborns.
Fumagalli, Monica; Cinnante, Claudia Maria; Calloni, Sonia Francesca; Sorrentino, Gabriele; Gorla, Ilaria; Plevani, Laura; Pesenti, Nicola; Sirgiovanni, Ida; Mosca, Fabio; Triulzi, Fabio
2018-03-29
The effects and potential hazards of brain magnetic resonance imaging (MRI) at 3 T in newborns are debated. Assess the impact of 3-T MRI in newborns on body temperature and physiological parameters. Forty-nine newborns, born preterm and at term, underwent 3-T brain MRI at term-corrected age. Rectal and skin temperature, oxygen saturation and heart rate were recorded before, during and after the scan. A statistically significant increase in skin temperature of 0.6 °C was observed at the end of the MRI scan (P<0.01). There was no significant changes in rectal temperature, heart rate or oxygen saturation. Core temperature, heart rate and oxygen saturation in newborns were not affected by 3-T brain MR scanning.
Thornton, John F; Schneider, Howard; McLean, Mary K; van Lierop, Muriel J; Tarzwell, Robert
2014-01-01
Brain single-photon emission computed tomography (SPECT) scans indirectly show functional activity via measurement of regional cerebral blood flow. Thirty patients at a community-based psychiatric clinic underwent brain SPECT scans. Changes in scoring of before-treatment and after-treatment scans correlated well with changes in patient Global Assessment of Functioning (GAF) scores before treatment and after treatment. Patients were retrospectively matched with controls with similar diagnoses and pretreatment GAF scores, and those who underwent SPECT-guided treatment improved significantly more than the control patients.
Meulepas, Johanna M; Ronckers, Cécile M; Merks, Johannes; Weijerman, Michel E; Lubin, Jay H; Hauptmann, Michael
2016-12-01
Recent studies linking radiation exposure from pediatric computed tomography (CT) to increased risks of leukemia and brain tumors lacked data to control for cancer susceptibility syndromes (CSS). These syndromes might be confounders because they are associated with an increased cancer risk and may increase the likelihood of pediatric CT scans. We identify CSS predisposing to leukemia and brain tumors through a systematic literature search and summarize prevalence and risk. Since empirical evidence is lacking in published literature on patterns of CT use for most types of CSS, we estimate confounding bias of relative risks (RR) for categories of radiation exposure based on expert opinion about patterns of CT scans among CSS patients. We estimate that radiation-related RRs for leukemia are not meaningfully confounded by Down syndrome, Noonan syndrome and other CSS. Moreover, tuberous sclerosis complex, von Hippel-Lindau disease, neurofibromatosis type 1 and other CSS do not meaningfully confound RRs for brain tumors. Empirical data on the use of CT scans among CSS patients is urgently needed. Our assessment indicates that associations with radiation exposure from pediatric CT scans and leukemia or brain tumors reported in previous studies are unlikely to be substantially confounded by unmeasured CSS.
Zhou, Yunfeng; Wang, Juan; Dassarath, Meera; Wang, Minhong; Zhang, Qiang; Xiong, Yuwei; Yuan, Quan
2015-01-01
To prospectively compare the new computed tomographic angiography (CTA) protocol (NCP) using 80-kV and dual-phase scanning with the routine CTA protocol (RCP) using 120-kV and single-phase scanning in patients with peripheral arterial disease. A total of 60 patients were randomized to undergo the NCP (30 patients) or RCP (30 patients) scan. We compared the arterial attenuation values, overriding of the contrast bolus, signal-to-noise ratio, and radiation dose between 2 groups. The occurrence rate of contrast bolus overriding was not statistically significant (P = 0.69). The average arterial attenuation value in the NCP group was significantly higher (P < 0.05) than that in the RCP group. The radiation dose in the RCP group was significantly higher (P < 0.001) than that in the NCP group. The mean signal-to-noise ratio in the NCP group was significantly lower (P < 0.001). Sixty-four-slice CTA with the NCP can significantly reduce the radiation dose and improve the arterial enhancement and calf arteries imaging.
Remote cerebellar hemorrhage following supratentorial craniotomy.
Huang, Chih-Yuan; Lee, Po-Hsuan; Lin, Sheng-Hsiang; Chuang, Ming-Tsung; Sun, Yuan-Ting; Hung, Yu-Chang; Lee, E-Jian
2012-06-01
Cerebellar hemorrhage remote from the site of surgery may complicate neurosurgical procedure. The exact pathophysiology of this type of hemorrhage is poorly understood. We retrospectively compared 16 patients who had remote cerebellar hemorrhage (RCH) with a case-matched control cohort, to determine the significance of perisurgical and surgical factors that may predispose patients to such bleeding events. From 1 June 2005 to 31 December 2008, postoperative routine head computed tomographic (CT) scan was performed in our institution and 16 patients with RCH after supratentorial neurosurgical procedure were identified. The medical charts of these 16 cases and a control cohort of 64 patients were recorded. All parameters were analyzed with regards to various variables. The incidence RCH after supratentorial craniotomy increased after postoperative computed tomographic scan. The mechanism of cerebellar hemorrhage in this series of patients is most likely multifactorial. Several variables showed a significant association with the occurrence of RCH. Multivariate analysis indicated that the following two factors independently correlated with occurrence of RCH: (1) postoperative epidural drainage amount; and (2) history of previous cerebrovascular accident (CVA) with cerebral atrophy. All cases with RCH underwent medical treatment and no neurological sequelae associated with RCH. Postoperative epidural drainage amount and history of previous CVA with cerebral atrophy can reliably predict the occurrence of cerebellar hemorrhage after supratentorial craniotomy. One of the most important strategies to minimize hazardous complications is to be aware of these potential risk factors and to take action to prevent them.
Variety of audiologic manifestations in patients with superior semicircular canal dehiscence.
Chi, Fang-Lu; Ren, Dong-Dong; Dai, Chun-Fu
2010-01-01
To present diverse symptoms, signs, and findings on diagnostic tests of 11 patients with superior semicircular canal dehiscence (SSCD) syndrome and surgical treatments for dehiscence of 3 patients. Retrospective case review. Tertiary neurotologic and audiologic center. Patients with SSCD documented by history, physical examination, vestibular function testing, and high-resolution computed tomographic scans. Two patients underwent surgical procedures through middle fossa approach, and 1 patient underwent transmastoid repair. The rest underwent conservative treatments. Eleven patients were identified as SSCD. The variety of clinical manifestations, including 1) hearing presentations: mix hearing loss (4 of 11), conductive hearing loss (3 of 11), profound sensorineural hearing loss (2 of 11), and normal hearing (2 of 11); 2) vestibular manifestations: chronic disequilibrium (8 of 11), Tullio phenomenon (7 of 11), Hennebert sign (8 of 11), tinnitus (3 of 11), and autophony (3 of 11); and 3) accompanying disorders: encephalomeningocele (1 of 11). Abnormal nystagmus was identified in 3 patients. Dehiscence of bone overlying superior semicircular canal was confirmed by high-resolution computed tomographic scan in all cases. Three patients underwent operative management. (2 through the middle fossa approach and 1 through a transmastoid repair). Superior semicircular canal dehiscence demonstrates diverse and complex clinical features. Tegmental or petrosal bone rarefaction or mild dehiscences can be a harbinger or an aggressive cause of developing SSCD. No correlation was observed between the size of dehiscence and the severity of vestibular symptoms or the degree of hearing loss. Surgical repair of dehiscence can relieve symptoms with low morbidity.
Thermoacoustic imaging of prostate cancer: comparison to histology
NASA Astrophysics Data System (ADS)
Patch, S. K.; Griep, S. K.; Jacobsohn, K.; See, W. A.; Hull, D.
2014-03-01
Ex vivo imaging of fresh prostate specimens was performed to test the hypothesis that the thermoacoustic (TA) contrast mechanism generated with very high frequency electromagnetic (EM) irradiation is sensitive to prostate cancer. Ex vivo imaging was performed immediately after radical prostatectomy, performed as part of normal care. Irradiation pulsewidth was 700 ns and duty cycle was extremely low. Typical specific absorption rate (SAR) throughout the prostate was 70-90 kW/kg during pulsing, but time-averaged SAR was below 2 W/kg. TA pressure pulses generated by rapid heating due to EM energy deposition were detected using single element transducers. 15g/L glycine powder mixed into DI water served as acoustic couplant, which was chilled to prevent autolysis. Spatial encoding was performed by scanning in tomographic "step-and-shoot" mode, with 3 mm translation between slices and 1.8-degree rotation between tomographic views. Histology slides for 3 cases scanned with 2.25 MHz transducers were marked for comparison to TA reconstructions. These three cases showed little, moderate, and severe involvement in the histology levels surrounding the verumontanum. TA signal strength decreased with percent cancerous involvement. When VHF is used for tissue heating, the TA contrast mechanism is driven by ionic content and we observed suppressed TA signal from diseased prostate tissue in the peripheral zone. For the 45 regions of interest analyzed, a reconstruction value of 0.4 mV provides 100% sensitivity but only 29% specificity.
Silvestrini Biavati, A; Tecco, S; Migliorati, M; Festa, F; Panza, G; Marzo, G; Gherlone, E; Tetè, S
2011-05-01
To evaluate the maxilla, mandible, and cortical plates on computerized tomographic (CT) scans to achieve accurate three-dimensional bone thickness measurements. We selected the CT scans of 25 subjects (among 102), aged 18-58 years (10 men, 15 women), with nearly complete dentition. We performed interradicular and bucco-lingual (including cortical plate thickness) measurements in dental areas distal to the canines in both alveolar arches, at three levels (5, 8, and 11 mm) from the alveolar ridge. The mean thicknesses of the cortical plates in the maxilla were 1.10 mm buccally and 1.27 mm on the palatal side (p < 0.05). In the mandible, cortical plates were 2.23 mm buccally and 2.02 mm lingually. Mandibular buccal and lingual cortical plates became thicker distally in the second and third molar areas. There was considerable variation in cortical thickness (from 0.25 to 5.50 mm). Based on interradicular distances, only 13% of measured sites in the maxilla were suitable for miniscrew insertion (≥3.3 mm), but 63% of sites were suitable in the mandible. This study showed considerable individual variation in bone thickness. Our data suggested that the palatal/lingual side may provide greater primary stability for miniscrews. The palatal area, between the second upper bicuspid and the first molar, appeared to be the most suitable area for tapered 7- to 9-mm miniscrews, starting at 1.5-2 mm from the alveolar crest. © 2011 John Wiley & Sons A/S.
Laterality and Left-sidedness in the Nose, Face, and Body: A New Finding.
Hafezi, Farhad; Javdani, Ali; Naghibzadeh, Bijan; Ashtiani, Abbas Kazemi
2017-12-01
Asymmetry is a common occurrence in bilaterian animals, particularly human beings. Through examination of patients and their photographs during rhinoplasty, we noted wider left-sided nasal and facial features in most patients. This observation led us to hypothesize that this might be consistent to the whole body. We conducted a study in 3 parts to test the question above. First, we analyzed operating notes of 50 rhinoplasty patients to determine the wider side of the upper, middle, and lower thirds of the nose. Second, we analyzed the width of the face and chest wall in 31 patients to discern any correlation between facial and bodily asymmetry. Third, computerized tomographic scans of the thorax and body of 48 patients were studied to measure the width of the hemithorax and hemipelvic bone. (1) Upper vault width was wider on left side (78%). Left middle vault width was wider (88%). The lower lateral cartilage, lateral crura convexity was more prominent on left side (48%), and a wider scroll area was found and trimmed in 21 (left) and 0 (right) cases. The alar base was wider on left side (56%). (2) In the body and face analysis, 64.5% had a wider left-sided face and body. (3) In the computed tomographic scan analysis, same-sided thorax and pelvis asymmetry was seen (85.35%), 33 and 7 of which were left- and right-sided, respectively. We observed generalized asymmetry of the face and body with left-sided predominance.
Correlative Fluorescence and Electron Microscopy in 3D-Scanning Electron Microscope Perspective.
Franks, Jonathan; Wallace, Callen T; Shibata, Masateru; Suga, Mitsuo; Erdman, Natasha; Stolz, Donna B; Watkins, Simon C
2017-04-03
The ability to correlate fluorescence microscopy (FM) and electron microscopy (EM) data obtained on biological (cell and tissue) specimens is essential to bridge the resolution gap between the data obtained by these different imaging techniques. In the past such correlations were limited to either EM navigation in two dimensions to the locations previously highlighted by fluorescence markers, or subsequent high-resolution acquisition of tomographic information using a TEM. We present a novel approach whereby a sample previously investigated by FM is embedded and subjected to sequential mechanical polishing and backscatter imaging by scanning electron microscope. The resulting three dimensional EM tomogram of the sample can be directly correlated to the FM data. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.
Simulation of Medical Imaging Systems: Emission and Transmission Tomography
NASA Astrophysics Data System (ADS)
Harrison, Robert L.
Simulation is an important tool in medical imaging research. In patient scans the true underlying anatomy and physiology is unknown. We have no way of knowing in a given scan how various factors are confounding the data: statistical noise; biological variability; patient motion; scattered radiation, dead time, and other data contaminants. Simulation allows us to isolate a single factor of interest, for instance when researchers perform multiple simulations of the same imaging situation to determine the effect of statistical noise or biological variability. Simulations are also increasingly used as a design optimization tool for tomographic scanners. This article gives an overview of the mechanics of emission and transmission tomography simulation, reviews some of the publicly available simulation tools, and discusses trade-offs between the accuracy and efficiency of simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal
2016-03-21
X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematicmore » investigation of complex samples containing both soft and hard materials.« less
Electron beam machining using rotating and shaped beam power distribution
Elmer, John W.; O'Brien, Dennis W.
1996-01-01
An apparatus and method for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: 1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and 2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1000 .mu.m (1 mm or larger), compared to the 250 .mu.m diameter of laser drilling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Yi, E-mail: yiguo@usc.edu; Zhu, Yinghua; Lingala, Sajan Goud
Purpose: To clinically evaluate a highly accelerated T1-weighted dynamic contrast-enhanced (DCE) MRI technique that provides high spatial resolution and whole-brain coverage via undersampling and constrained reconstruction with multiple sparsity constraints. Methods: Conventional (rate-2 SENSE) and experimental DCE-MRI (rate-30) scans were performed 20 minutes apart in 15 brain tumor patients. The conventional clinical DCE-MRI had voxel dimensions 0.9 × 1.3 × 7.0 mm{sup 3}, FOV 22 × 22 × 4.2 cm{sup 3}, and the experimental DCE-MRI had voxel dimensions 0.9 × 0.9 × 1.9 mm{sup 3}, and broader coverage 22 × 22 × 19 cm{sup 3}. Temporal resolution was 5 smore » for both protocols. Time-resolved images and blood–brain barrier permeability maps were qualitatively evaluated by two radiologists. Results: The experimental DCE-MRI scans showed no loss of qualitative information in any of the cases, while achieving substantially higher spatial resolution and whole-brain spatial coverage. Average qualitative scores (from 0 to 3) were 2.1 for the experimental scans and 1.1 for the conventional clinical scans. Conclusions: The proposed DCE-MRI approach provides clinically superior image quality with higher spatial resolution and coverage than currently available approaches. These advantages may allow comprehensive permeability mapping in the brain, which is especially valuable in the setting of large lesions or multiple lesions spread throughout the brain.« less
A 1-minute full brain MR exam using a multicontrast EPI sequence.
Skare, Stefan; Sprenger, Tim; Norbeck, Ola; Rydén, Henric; Blomberg, Lars; Avventi, Enrico; Engström, Mathias
2018-06-01
A new multicontrast echo-planar imaging (EPI)-based sequence is proposed for brain MRI, which can directly generate six MR contrasts (T 1 -FLAIR, T 2 -w, diffusion-weighted (DWI), apparent diffusion coefficient (ADC), T2*-w, T 2 -FLAIR) in 1 min with full brain coverage. This could enable clinical MR clinical screening in similar time as a conventional CT exam but with more soft-tissue information. Eleven sequence modules were created as dynamic building blocks for the sequence. Two EPI readout modules were reused throughout the sequence and were prepended by other modules to form the desired MR contrasts. Two scan protocols were optimized with scan times of 55-75 s. Motion experiments were carried out on two volunteers to investigate the robustness against head motion. Scans on patients were carried out and compared to conventional clinical images. The pulse sequence is found to be robust against motion given its single-shot nature of each contrast. For excessive out-of-plane head motion, the T 1 -FLAIR and T 2 -FLAIR contrasts suffer from incomplete inversion. Despite lower signal-to-noise ratio (SNR) and resolution, the 1-min multicontrast EPI data show promising correspondence with conventional diagnostic scans on patients. A 1 min multicontrast brain MRI scan based on EPI readouts has been presented in this feasibility study. Preliminary data show potential for clinical brain MRI use with minimal bore time for the patient. Such short examination time could be useful (e.g., for screening and acute stroke). The sequence may also help planning conventional brain MRI scans if run at the beginning of an examination. Magn Reson Med 79:3045-3054, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa
2015-12-01
The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P < .05). After instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P < .05). Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P < .05). There were no significant differences between instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Hwang, Jeong-Hwa; Misumi, Shigeki; Sahin, Hakan; Brown, Kevin K; Newell, John D; Lynch, David A
2009-01-01
To compare the computed tomographic (CT) features of idiopathic fibrosing interstitial pneumonia with those of pulmonary fibrosis related to collagen vascular disease (CVD). We reviewed the CT scans of 177 patients with diffuse interstitial pulmonary fibrosis, of which 97 had idiopathic fibrosing interstitial pneumonia and 80 had CVD. The CT images were systematically scored for the presence and extent of pulmonary and extrapulmonary abnormalities. Computed tomographic diagnosis of usual interstitial pneumonia (UIP) or nonspecific interstitial pneumonia (NSIP) was assigned. A CT pattern of UIP was identified in 59 (60.8%) of patients with idiopathic fibrosing interstitial pneumonia compared with 15 (18.7%) of those patients with CVD; conversely, the CT diagnosis of NSIP was made in 51 (64%) of patients with CVD compared with 36 (37%) of patients with idiopathic disease (P < 0.01). In 113 patients who had lung biopsy, the CT diagnoses of UIP and NSIP were concordant with the histologic diagnoses in 36 of 50 patients and 34 of 41 patients, respectively. Pleural effusions, esophageal dilation, and pericardial abnormalities were more frequent in patients with CVD than in patients with idiopathic fibrosing interstitial pneumonia. Compared with patients with CVD, those patients with an idiopathic fibrosing interstitial pneumonia showed a higher prevalence of a UIP pattern and lower prevalence of an NSIP pattern as determined by CT. Identification of coexisting extrapulmonary abnormalities on CT can support a diagnosis of CVD.
Cappellozza, José Antonio Zuega; Guedes, Fabio Pinto; Nary, Hugo; Capelozza, Leopoldino; Cardoso, Mauricio de Almeida
2015-01-01
Introduction: Cone-Beam Computed Tomography (CBCT) is essential for tridimensional planning of orthognathic surgery, as it allows visualization and evaluation of bone structures and mineralized tissues. Tomographic slices allow evaluation of tooth inclination and individualization of movement performed during preoperative decompensation. The aim of this paper was to assess maxillary and mandibular incisors inclination pre and post orthodontic decompensation in skeletal Class III malocclusion. Methods: The study was conducted on six individuals with skeletal Class III malocclusion, surgically treated, who had Cone-Beam Computed Tomographic scans obtained before and after orthodontic decompensation. On multiplanar reconstruction view, tomographic slices (axial, coronal and sagittal) were obtained on the long axis of each incisor. The sagittal slice was used for measurement taking, whereas the references used to assess tooth inclination were the long axis of maxillary teeth in relation to the palatal plane and the long axis of mandibular teeth in relation to the mandibular plane. Results: There was significant variation in the inclination of incisors before and after orthodontic decompensation. This change was of greater magnitude in the mandibular arch, evidencing that natural compensation is more effective in this arch, thereby requiring more intensive decompensation. Conclusion: When routinely performed, the protocols of decompensation treatment in surgical individuals often result in intensive movements, which should be reevaluated, since the extent of movement predisposes to reduction in bone attachment levels and root length. PMID:26560818
Chhabra, Lovely; Sareen, Pooja; Gandagule, Amit; Spodick, David H
2012-03-01
Verticalization of the frontal P vector in patients older than 45 years is virtually diagnostic of pulmonary emphysema (sensitivity, 96%; specificity, 87%). We investigated the correlation of P vector and the computed tomographic visual score of emphysema (VSE) in patients with established diagnosis of chronic obstructive pulmonary disease/emphysema. High-resolution computed tomographic scans of 26 patients with emphysema (age, >45 years) were reviewed to assess the type and extent of emphysema using the subjective visual scoring. Electrocardiograms were independently reviewed to determine the frontal P vector. The P vector and VSE were compared for statistical correlation. Both P vector and VSE were also directly compared with the forced expiratory volume at 1 second. The VSE and the orientation of the P vector (ÂP) had an overall significant positive correlation (r = +0.68; P = .0001) in all patients, but the correlation was very strong in patients with predominant lower-lobe emphysema (r = +0.88; P = .0004). Forced expiratory volume at 1 second and ÂP had almost a linear inverse correlation in predominant lower-lobe emphysema (r = -0.92; P < .0001). Orientation of the P vector positively correlates with visually scored emphysema. Both ÂP and VSE are strong reflectors of qualitative lung function in patients with predominant lower-lobe emphysema. A combination of more vertical ÂP and predominant lower-lobe emphysema reflects severe obstructive lung dysfunction. Copyright © 2012 Elsevier Inc. All rights reserved.
Clinical multiphoton FLIM tomography
NASA Astrophysics Data System (ADS)
König, Karsten
2012-03-01
This paper gives an overview on current clinical high resolution multiphoton fluorescence lifetime imaging in volunteers and patients. Fluorescence lifetime imaging (FLIM) in Life Sciences was introduced in Jena/Germany in 1988/89 based on a ZEISS confocal picosecond dye laser scanning microscope equipped with a single photon counting unit. The porphyrin distribution in living cells and living tumor-bearing mice was studied with high spatial, temporal, and spectral resolution. Ten years later, time-gated cameras were employed to detect dental caries in volunteers based on one-photon excitation of autofluorescent bacteria with long fluorescence lifetimes. Nowadays, one-photon FLIM based on picosecond VIS laser diodes are used to study ocular diseases in humans. Already one decade ago, first clinical twophoton FLIM images in humans were taken with the certified clinical multiphoton femtosecond laser tomograph DermaInspectTM. Multiphoton tomographs with FLIM modules are now operating in hospitals at Brisbane, Tokyo, Berlin, Paris, London, Modena and other European cities. Multiple FLIM detectors allow spectral FLIM with a temporal resolution down to 20 ps (MCP) / 250 ps (PMT) and a spectral resolution of 10 nm. Major FLIM applications include the detection of intradermal sunscreen and tattoo nanoparticles, the detection of different melanin types, the early diagnosis of dermatitis and malignant melanoma, as well as the measurement of therapeutic effects in pateints suffering from dermatitis. So far, more than 1,000 patients and volunteers have been investigated with the clinical multiphoton FLIM tomographs DermaInspectTM and MPTflexTM.
Longo, Maurizio; Andreis, Maria Elena; Pettinato, Cinzia; Ravasio, Giuliano; Rabbogliatti, Vanessa; De Zani, Donatella; Di Giancamillo, Mauro; Zani, Davide Danilo
2016-03-29
The aim of the work is the application of a bolus tracking technique for tomographic evaluation of the uretero-vesicular junction in dogs. Ten adult dogs (8-14 years) with variable body weight (2,8-32 kg) were enrolled in the prospective study. The patients were placed in sternal recumbency with a 10° elevated pelvis and the visualization of the uretero-vesicular junction was obtained with the bolus tracking technique after intravenous administration of non-ionic contrast medium. In the post-contrast late phase a region of interest was placed within the lumen of the distal ureters and the density values were monitored before starting the helical scan. The uretero-vesicular junction was clearly visible in 100% of patients with the visualization of the endoluminal ureteral contrast enhancement and bladder washout. At the end of the tomographic study an evaluation of the dose records was performed and compared to human exposures reported in literature for the pelvic region. The effective dose estimated for each patient (37,5-138 mSv) proved to be elevated, when compared to those reported in human patients. The bolus tracking technique could be applied for the visualization of the uretero-vesicular junction in non-pathological patients, placing the region of interest in the distal ureters. The high effective doses recorded in our study support the need of specific thresholds for veterinary patients, pointing out the attention for paediatric patient's exposure also in veterinary imaging.
A New Femtosecond Laser-Based Three-Dimensional Tomography Technique
NASA Astrophysics Data System (ADS)
Echlin, McLean P.
2011-12-01
Tomographic imaging has dramatically changed science, most notably in the fields of medicine and biology, by producing 3D views of structures which are too complex to understand in any other way. Current tomographic techniques require extensive time both for post-processing and data collection. Femtosecond laser based tomographic techniques have been developed in both standard atmosphere (femtosecond laser-based serial sectioning technique - FSLSS) and in vacuum (Tri-Beam System) for the fast collection (10 5mum3/s) of mm3 sized 3D datasets. Both techniques use femtosecond laser pulses to selectively remove layer-by-layer areas of material with low collateral damage and a negligible heat affected zone. To the authors knowledge, femtosecond lasers have never been used to serial section and these techniques have been entirely and uniquely developed by the author and his collaborators at the University of Michigan and University of California Santa Barbara. The FSLSS was applied to measure the 3D distribution of TiN particles in a 4330 steel. Single pulse ablation morphologies and rates were measured and collected from literature. Simultaneous two-phase ablation of TiN and steel matrix was shown to occur at fluences of 0.9-2 J/cm2. Laser scanning protocols were developed minimizing surface roughness to 0.1-0.4 mum for laser-based sectioning. The FSLSS technique was used to section and 3D reconstruct titanium nitride (TiN) containing 4330 steel. Statistical analysis of 3D TiN particle sizes, distribution parameters, and particle density were measured. A methodology was developed to use the 3D datasets to produce statistical volume elements (SVEs) for toughness modeling. Six FSLSS TiN datasets were sub-sampled into 48 SVEs for statistical analysis and toughness modeling using the Rice-Tracey and Garrison-Moody models. A two-parameter Weibull analysis was performed and variability in the toughness data agreed well with Ruggieri et al. bulk toughness measurements. The Tri-Beam system combines the benefits of laser based material removal (speed, low-damage, automated) with detectors that collect chemical, structural, and topological information. Multi-modal sectioning information was collected after many laser scanning passes demonstrating the capability of the Tri-Beam system.
Gold Nanoparticle Quantitation by Whole Cell Tomography.
Sanders, Aric W; Jeerage, Kavita M; Schwartz, Cindi L; Curtin, Alexandra E; Chiaramonti, Ann N
2015-12-22
Many proposed biomedical applications for engineered gold nanoparticles require their incorporation by mammalian cells in specific numbers and locations. Here, the number of gold nanoparticles inside of individual mammalian stem cells was characterized using fast focused ion beam-scanning electron microscopy based tomography. Enhanced optical microscopy was used to provide a multiscale map of the in vitro sample, which allows cells of interest to be identified within their local environment. Cells were then serially sectioned using a gallium ion beam and imaged using a scanning electron beam. To confirm the accuracy of single cross sections, nanoparticles in similar cross sections were imaged using transmission electron microscopy and scanning helium ion microscopy. Complete tomographic series were then used to count the nanoparticles inside of each cell and measure their spatial distribution. We investigated the influence of slice thickness on counting single particles and clusters as well as nanoparticle packing within clusters. For 60 nm citrate stabilized particles, the nanoparticle cluster packing volume is 2.15 ± 0.20 times the volume of the bare gold nanoparticles.
NASA Astrophysics Data System (ADS)
Latief, F. D. E.; Mohammad, I. H.; Rarasati, A. D.
2017-11-01
Digital imaging of a concrete sample using high resolution tomographic imaging by means of X-Ray Micro Computed Tomography (μ-CT) has been conducted to assess the characteristic of the sample’s structure. A standard procedure of image acquisition, reconstruction, image processing of the method using a particular scanning device i.e., the Bruker SkyScan 1173 High Energy Micro-CT are elaborated. A qualitative and a quantitative analysis were briefly performed on the sample to deliver some basic ideas of the capability of the system and the bundled software package. Calculation of total VOI volume, object volume, percent of object volume, total VOI surface, object surface, object surface/volume ratio, object surface density, structure thickness, structure separation, total porosity were conducted and analysed. This paper should serve as a brief description of how the device can produce the preferred image quality as well as the ability of the bundled software packages to help in performing qualitative and quantitative analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aita, J.F.; Keyes, J.W. Jr.
Two cases of acute infantile hemiplegia are presented. The first case is a patient with moyamoya disease with excellent correlation between the brain scan findings and her clinical signs and symptoms and the carotid arteriogram. The second patient had occlusive cerebrovascular disease secondary to thromboemboli with excellent correlation between the brain scan findings and his clinical state and the neuropathologic examination. In both cases the static brain scans and the radionuclide angiogram were comparable to those reported in adults with cerebrovascular disease both in appearance and in temporal sequence. Radionuclide studies can be an important and reliable diagnostic tool inmore » the evaluation of acute infantile hemiplegia. (auth)« less
Barragán-Hervella, Rodolfo; Montiel-Jarquín, Álvaro; Limón-Serrano, Iván; Escobedo-Sosa, Víctor; Loría-Castellanos, Jorge
To describe the direct cost of primary health care for patients with mild traumatic head injury in a third level medical facility. Cross-sectional study in 219 patients with mild traumatic brain injury (GRD 090 S06.0 ICD-10 including uncomplicated concussion without complication and increased comorbidity). A medical unit of tertiary care in the State of Puebla, Mexico. Direct costs were taken from ACDO.AS3.HCT.280115 / 7.P.DF Agreement and its annexes in Mexican pesos, the variables analyzed were age, gender, shift attention, laboratory, radiographic and tomographic studies, length of stay, specialist consultations, emergency care, medicines, and treatment materials. Descriptive statistics on SPSS program IBM v22. 53.4% male, 46.6% female; average age 31.9 years; morning shift attention 58.4%, evening 23.3%, and nightly 18.3%. The cost: $ 1,755 laboratory, plain radiographs $ 202,794, tomographic studies $ 26,720, consultation with neurosurgeon $ 279,174, emergency care $ 501,510; curing material: single steri drape $8,326.38, Micropore $1,307.43, infusion equipment $790.59, venipuncture needle $7,408.77; drugs: diclofenac $946.08, Ketorolac $724.89, 1000 ml. intravenous solution $1,561.47, total cost $ 1,032,293.72, average/patient: 4,713.66 Mexican pesos. The direct cost of primary health care of patients with mild traumatic head injury is high; sticking to the correct handling decreases the cost of attention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langerak, Thomas, E-mail: t.langerak@erasmusmc.nl; Mens, Jan Willem; Quint, Sandra
Purpose: To evaluate a new type of marker and a new method of marker implantation and to assess interfraction cervix motion for a large population of patients with locally advanced cervical cancer by daily cone beam computed tomographic (CBCT) imaging. Methods and Materials: We investigated the position of markers in 50 patients treated in prone position during at least 23 fractions. To reduce streaking artifacts in the planning CT scan, a new type of polymeric marker was used and compared with conventional gold markers. In addition, a new method of implantation was used in an attempt to reduce marker loss.more » In each fraction, a CT scan was acquired before dose delivery and aligned to the bony anatomy of the planning CT scan, simulating the clinical setup protocol. First, sufficient visibility of the markers was verified. Then, systematic and random displacement of the marker centroids was recorded and analyzed in 3 directions with regard to the planning CT and the first CBCT (to evaluate the presence of a vaginal catheter in the planning CT). Streaking artifacts were quantified with the standard deviation of the mean squared intensity difference in a radius around the marker. Results: Marker loss was minimal during treatment: in only 3 of the 50 patients 1 marker was lost. Streaking artifacts for the new markers were reduced compared with conventional gold markers. For the planning CT, M/Σ/σ were 0.4/3.4/2.2 mm, 1.0/5.5/4.5 mm, and −3.9/5.1/3.6 mm for the left-right, anterior-posterior, and cranial-caudal directions, respectively. With regard to the first CBCT scan, M/Σ/σ were 0.8/2.8/2.1, 0.6/4.4/4.4, and −1.3/4.5/3.6 mm. Conclusions: A new type of marker and implantation method was shown to have significantly reduced marker loss and streaking artifacts compared with gold fiducial markers. The recorded marker displacement confirms results reported in the existing literature but for a larger dataset.« less
Heuser, Gunnar; Heuser, Sylvia A
2017-09-26
Ten adult patients with electromagnetic hypersensitivity underwent functional magnetic resonance imaging (fMRI) brain scans. All scans were abnormal with abnormalities which were consistent and similar. It is proposed that fMRI brain scans be used as a diagnostic aid for determining whether or not a patient has electromagnetic hypersensitivity. Over the years we have seen an increasing number of patients who had developed multi system complaints after long term repeated exposure to electromagnetic fields (EMFs). These complaints included headaches, intermittent cognitive and memory problems, intermittent disorientation, and also sensitivity to EMF exposure. Regular laboratory tests were within normal limits in these patients. The patients refused to be exposed to radioactivity. This of course ruled out positron emission tomography (PET) and single-photon emission computed tomography (SPECT) brain scanning. This is why we ordered fMRI brain scans on these patients. We hoped that we could document objective abnormalities in these patients who had often been labeled as psychiatric cases. Ten patients first underwent a regular magnetic resonance imaging (MRI) brain scan, using a 3 Tesla Siemens Verio MRI open system. A functional MRI study was then performed in the resting state using the following sequences: A three-dimensional, T1-weighted, gradient-echo (MPRAGE) Resting state network. The echo-planar imaging (EPI) sequences for this resting state blood oxygenation level dependent (BOLD) scan were then post processed on a 3D workstation and the independent component analysis was performed separating out the various networks. Arterial spin labeling. Tractography and fractional anisotropy. All ten patients had abnormal functional MRI brain scans. The abnormality was often described as hyper connectivity of the anterior component of the default mode in the medial orbitofrontal area. Other abnormalities were usually found. Regular MRI studies of the brain were mostly unremarkable in these patients. We propose that functional MRI studies should become a diagnostic aid when evaluating a patient who claims electrohypersensitivity (EHS) and has otherwise normal studies. Interestingly, the differential diagnosis for the abnormalities seen on the fMRI includes head injury. It turns out that many of our patients indeed had a history of head injury which was then followed sometime later by the development of EHS. Many of our patients also had a history of exposure to potentially neurotoxic chemicals, especially mold. Head injury and neurotoxic chemical exposure may make a patient more vulnerable to develop EHS.
Öğrenci, Ahmet; Koban, Orkun; Ekşi, Murat; Yaman, Onur; Dalbayrak, Sedat
2017-01-01
AIM: This study aimed to make a retrospective analysis of pediatric patients with head traumas that were admitted to one hospital setting and to make an analysis of the patients for whom follow-up CT scans were obtained. METHODS: Pediatric head trauma cases were retrospectively retrieved from the hospital’s electronic database. Patients’ charts, CT scans and surgical notes were evaluated by one of the authors. Repeat CT scans for operated patients were excluded from the total number of repeat CT scans. RESULTS: One thousand one hundred and thirty-eight pediatric patients were admitted to the clinic due to head traumas. Brain CT scan was requested in 863 patients (76%) in the cohort. Follow-up brain CT scans were obtained in 102 patients. Additional abnormal finding requiring surgical intervention was observed in only one patient (isolated 4th ventricle hematoma) on the control CTs (1% of repeat CT scans), who developed obstructive hydrocephalus. None of the patients with no more than 1 cm epidural hematoma in its widest dimension and repeat CT scans obtained 1.5 hours after the trauma necessitated surgery. CONCLUSION: Follow-up CT scans changed clinical approach in only one patient in the present series. When ordering CT scan in the follow-up of pediatric traumas, benefits and harms should be weighted based upon time interval from trauma onset to initial CT scan and underlying pathology. PMID:29104682
2013-04-13
the radiation passed through the subject. For conventional CT, this value is called a Hounsfield unit (HU), named in the honor of Godfrey Hounsfield ...concretions and tonsilloliths. Otolaryngol Clin North Am. 1987 May;20(2):305-9. 39. Reeves TE, Mah P, McDavid WD. Deriving Hounsfield units using grey...study are those of the authors and do not reflect the official policy of the United States Air Force, the Department of Defense, or the United States
Chauhan, Narvir Singh; Sharma, Yash Paul; Bhagra, Tilak; Sud, Bindu
2012-01-01
Anomalies of third or fourth branchial apparatus origin are very uncommon and present as recurrent neck infections or thyroiditis with a predominant left-sided involvement. Radiological diagnosis requires a high index of suspicion and is critical for initiation of proper treatment. We describe a case of branchial sinus of pyriform fossa with external fistulization that presented in adulthood and was diagnosed on computed tomographic scan. The radiological features of this rare anomaly are revisited. Copyright © 2012 Elsevier Inc. All rights reserved.
Bilateral choroidal osteomas associated with fatal systemic illness.
Kline, L B; Skalka, H W; Davidson, J D; Wilmes, F J
1982-02-01
An 11-year-old black boy complained of intermittent occipital headaches with nausea and projectile vomiting. Previous skin and lung biopsy specimens were interpreted as histiocytosis X. Cranial computed tomographic scanning disclosed a mass lesion in the region of the choroid plexus of the left lateral ventricle. This was surgically removed but proved nondiagnostic despite extensive histologic examination. An ophthalmologic evaluation showed discrete, elevated, yellow-white choroidal tumors in both maculas. The ophthalmoscopic appearance, as well as ultrasonography and computed tomography, led to the diagnosis of choroidal osteomas.
NASA Astrophysics Data System (ADS)
Lippitz, Nicolas; Erdeniz, Dinc; Sharp, Keith W.; Dunand, David C.
2018-03-01
Braided tubes of Ni-based superalloys are fabricated via three-dimensional (3-D) braiding of ductile Ni-20Cr (wt pct) wires followed by post-textile gas-phase alloying with Al and Ti to create, after homogenization and aging, γ/ γ' strengthened lightweight, porous structures. Tensile tests reveal an increase in strength by 100 MPa compared to as-braided Ni-20Cr (wt pct). An interrupted tensile test, combined with X-ray tomographic scans between each step, sheds light on the failure behavior of the braided superalloy tubes.
SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobson, D; Liu, Y
2016-06-15
Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes.more » The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.« less
Limited-angle tomography for analyzer-based phase-contrast X-ray imaging
Majidi, Keivan; Wernick, Miles N; Li, Jun; Muehleman, Carol; Brankov, Jovan G
2014-01-01
Multiple-Image Radiography (MIR) is an analyzer-based phase-contrast X-ray imaging method (ABI), which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume. PMID:24898008
Limited-angle tomography for analyzer-based phase-contrast x-ray imaging
NASA Astrophysics Data System (ADS)
Majidi, Keivan; Wernick, Miles N.; Li, Jun; Muehleman, Carol; Brankov, Jovan G.
2014-07-01
Multiple-image radiography (MIR) is an analyzer-based phase-contrast x-ray imaging method, which is emerging as a potential alternative to conventional radiography. MIR simultaneously generates three planar parametric images containing information about scattering, refraction and attenuation properties of the object. The MIR planar images are linear tomographic projections of the corresponding object properties, which allows reconstruction of volumetric images using computed tomography (CT) methods. However, when acquiring a full range of linear projections around the tissue of interest is not feasible or the scanning time is limited, limited-angle tomography techniques can be used to reconstruct these volumetric images near the central plane, which is the plane that contains the pivot point of the tomographic movement. In this work, we use computer simulations to explore the applicability of limited-angle tomography to MIR. We also investigate the accuracy of reconstructions as a function of number of tomographic angles for a fixed total radiation exposure. We use this function to find an optimal range of angles over which data should be acquired for limited-angle tomography MIR (LAT-MIR). Next, we apply the LAT-MIR technique to experimentally acquired MIR projections obtained in a cadaveric human thumb study. We compare the reconstructed slices near the central plane to the same slices reconstructed by CT-MIR using the full angular view around the object. Finally, we perform a task-based evaluation of LAT-MIR performance for different numbers of angular views, and use template matching to detect cartilage in the refraction image near the central plane. We use the signal-to-noise ratio of this test as the detectability metric to investigate an optimum range of tomographic angles for detecting soft tissues in LAT-MIR. Both results show that there is an optimum range of angular view for data acquisition where LAT-MIR yields the best performance, comparable to CT-MIR only if one considers volumetric images near the central plane and not the whole volume.
Improved scatter correction with factor analysis for planar and SPECT imaging
NASA Astrophysics Data System (ADS)
Knoll, Peter; Rahmim, Arman; Gültekin, Selma; Šámal, Martin; Ljungberg, Michael; Mirzaei, Siroos; Segars, Paul; Szczupak, Boguslaw
2017-09-01
Quantitative nuclear medicine imaging is an increasingly important frontier. In order to achieve quantitative imaging, various interactions of photons with matter have to be modeled and compensated. Although correction for photon attenuation has been addressed by including x-ray CT scans (accurate), correction for Compton scatter remains an open issue. The inclusion of scattered photons within the energy window used for planar or SPECT data acquisition decreases the contrast of the image. While a number of methods for scatter correction have been proposed in the past, in this work, we propose and assess a novel, user-independent framework applying factor analysis (FA). Extensive Monte Carlo simulations for planar and tomographic imaging were performed using the SIMIND software. Furthermore, planar acquisition of two Petri dishes filled with 99mTc solutions and a Jaszczak phantom study (Data Spectrum Corporation, Durham, NC, USA) using a dual head gamma camera were performed. In order to use FA for scatter correction, we subdivided the applied energy window into a number of sub-windows, serving as input data. FA results in two factor images (photo-peak, scatter) and two corresponding factor curves (energy spectra). Planar and tomographic Jaszczak phantom gamma camera measurements were recorded. The tomographic data (simulations and measurements) were processed for each angular position resulting in a photo-peak and a scatter data set. The reconstructed transaxial slices of the Jaszczak phantom were quantified using an ImageJ plugin. The data obtained by FA showed good agreement with the energy spectra, photo-peak, and scatter images obtained in all Monte Carlo simulated data sets. For comparison, the standard dual-energy window (DEW) approach was additionally applied for scatter correction. FA in comparison with the DEW method results in significant improvements in image accuracy for both planar and tomographic data sets. FA can be used as a user-independent approach for scatter correction in nuclear medicine.
Direct imaging of neural currents using ultra-low field magnetic resonance techniques
Volegov, Petr L [Los Alamos, NM; Matlashov, Andrei N [Los Alamos, NM; Mosher, John C [Los Alamos, NM; Espy, Michelle A [Los Alamos, NM; Kraus, Jr., Robert H.
2009-08-11
Using resonant interactions to directly and tomographically image neural activity in the human brain using magnetic resonance imaging (MRI) techniques at ultra-low field (ULF), the present inventors have established an approach that is sensitive to magnetic field distributions local to the spin population in cortex at the Larmor frequency of the measurement field. Because the Larmor frequency can be readily manipulated (through varying B.sub.m), one can also envision using ULF-DNI to image the frequency distribution of the local fields in cortex. Such information, taken together with simultaneous acquisition of MEG and ULF-NMR signals, enables non-invasive exploration of the correlation between local fields induced by neural activity in cortex and more `distant` measures of brain activity such as MEG and EEG.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pagani, J.J.; Hayman, L.A.; Bigelow, R.H.
1983-04-01
The effect of 5 mg of intravenous diazepam (Valium) on contrast media-associated seizer incidence was studied in a randomized controlled trial involving 284 patients with known or suspected brain metastases undergoing cerebral computed tomography. Of these patients, 188 were found to have brain metastases, and it is estimated that for this subgroup prophylactic diazepam reduces the risk of contrast-assocated seizure by a factor of 0.26. Seizures occurred in three of 96 patients with metastases on diazepam and in 14 of 92 patients with metastases but without diazepam. Factors related to increased risk of contrast media-associated seizures are: (1) prior seizuremore » history due to brain metatases and/or prior contrast, (2) progressive cerebral metastases, and (3) prior or concurrent brain antineoplastic therapy. Factors not related to an increased risk of these seizures are: (1) contrast media dosage, chemical composition, or osmolarity, (2) computed tomographic appearance of metastases, and (3) type of primary malignancy. Concomitant therapeutic levels of diphenylhydantoin (Dilantin) do not protect completely against contrast media-associated seizures. Pathophysiology of contrast media-associated seizures is discussed in view of the risk factors determined by this study.« less
Barnea-Goraly, Naama; Weinzimer, Stuart A.; Mauras, Nelly; Beck, Roy W.; Marzelli, Matt J.; Mazaika, Paul K.; Aye, Tandy; White, Neil H.; Tsalikian, Eva; Fox, Larry; Kollman, Craig; Cheng, Peiyao; Reiss, Allan L.
2013-01-01
Background The ability to lie still in an MRI scanner is essential for obtaining usable image data. To reduce motion, young children are often sedated, adding significant cost and risk. Objective We assessed the feasibility of using a simple and affordable behavioral desensitization program to yield high-quality brain MRI scans in sedation-free children. Materials and methods 222 children (4–9.9 years), 147 with type 1 diabetes and 75 age-matched non-diabetic controls, participated in a multi-site study focused on effects of type 1 diabetes on the developing brain. T1-weighted and diffusion-weighted imaging (DWI) MRI scans were performed. All children underwent behavioral training and practice MRI sessions using either a commercial MRI simulator or an inexpensive mock scanner consisting of a toy tunnel, vibrating mat, and video player to simulate the sounds and feel of the MRI scanner. Results 205 children (92.3%), mean age 7±1.7 years had high-quality T1-W scans and 174 (78.4%) had high-quality diffusion-weighted scans after the first scan session. With a second scan session, success rates were 100% and 92.5% for T1-and diffusion-weighted scans, respectively. Success rates did not differ between children with type 1 diabetes and children without diabetes, or between centers using a commercial MRI scan simulator and those using the inexpensive mock scanner. Conclusion Behavioral training can lead to a high success rate for obtaining high-quality T1-and diffusion-weighted brain images from a young population without sedation. PMID:24096802
Brain MRI volumetry in a single patient with mild traumatic brain injury.
Ross, David E; Castelvecchi, Cody; Ochs, Alfred L
2013-01-01
This letter to the editor describes the case of a 42 year old man with mild traumatic brain injury and multiple neuropsychiatric symptoms which persisted for a few years after the injury. Initial CT scans and MRI scans of the brain showed no signs of atrophy. Brain volume was measured using NeuroQuant®, an FDA-approved, commercially available software method. Volumetric cross-sectional (one point in time) analysis also showed no atrophy. However, volumetric longitudinal (two points in time) analysis showed progressive atrophy in several brain regions. This case illustrated in a single patient the principle discovered in multiple previous group studies, namely that the longitudinal design is more powerful than the cross-sectional design for finding atrophy in patients with traumatic brain injury.
Meulepas, Johanna M; Ronckers, Cécile M; Merks, Johannes; Weijerman, Michel E; Lubin, Jay H; Hauptmann, Michael
2016-01-01
Recent studies linking radiation exposure from pediatric computed tomography (CT) to increased risks of leukemia and brain tumors lacked data to control for cancer susceptibility syndromes (CSS). These syndromes might be confounders because they are associated with an increased cancer risk and may increase the likelihood of CT scans performed in children. We identify CSS predisposing to leukemia and brain tumors through a systematic literature search and summarize prevalence and risk estimates. Because there is virtually no empirical evidence in published literature on patterns of CT use for most types of CSS, we estimate confounding bias of relative risks (RR) for categories of radiation exposure based on expert opinion about the current and previous patterns of CT scans among CSS patients. We estimate that radiation-related RRs for leukemia are not meaningfully confounded by Down syndrome, Noonan syndrome, or other CSS. In contrast, RRs for brain tumors may be overestimated due to confounding by tuberous sclerosis complex (TSC) while von Hippel-Lindau disease, neurofibromatosis type 1, or other CSS do not meaningfully confound. Empirical data on the use of CT scans among CSS patients are urgently needed. Our assessment indicates that associations with leukemia reported in previous studies are unlikely to be substantially confounded by unmeasured CSS, whereas brain tumor risks might have been overestimated due to confounding by TSC. Future studies should identify TSC patients in order to avoid overestimation of brain tumor risks due to radiation exposure from CT scans. ©2015 American Association for Cancer Research.
Chakkarapani, Elavazhagan; Chau, Vann; Poskitt, Kenneth J; Synnes, Anne; Kwan, Eddie; Roland, Elke; Miller, Steven P
2016-09-01
To determine the association between lowest plasma magnesium concentration and brain metabolism, and whether magnetic resonance imaging brain injury patterns moderated the association in hypoxic-ischemic encephalopathy. In 131 early (day-of-life 3) and 65 late (day-of-life 10) scans of term encephalopathic infants born between 2004 and 2012, we examined the association of lowest plasma magnesium (until day-of-life 3) on basal ganglia and white matter peak metabolite ratios on magnetic resonance spectroscopy independent of covariates, stratified by the predominant patterns of injury (normal, basal nuclei/total, watershed, multifocal) using multiple linear regression. Lowest plasma magnesium was associated with lower white matter N-acetyl-aspartate/choline in the multifocal pattern on early scan (regression-coefficient, β: 0.13; 95% CI: 0.04, 0.22) and in the basal nuclei/total pattern on late scan (β: 0.08; 95% CI: 0.02, 0.15), and was negatively associated with basal ganglia lactate/N-acetyl-aspartate (β: -0.16; 95% CI: -0.05, -0.28) and lactate/choline (β: -0.1; 95% CI: -0.03, -0.17) ratio in the basal nuclei/total pattern on late scan independent of hypomagnesaemia correction, cooling and postmenstrual age at scan. Lowest plasma magnesium was not associated with metabolite ratios in other brain injury patterns. In infants with hypoxic-ischaemic encephalopathy, predominant patterns of brain injury moderated the association between lowest plasma magnesium in the first three days of life and impaired brain metabolism. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Integration of stereotactic ultrasonic data into an interactive image-guided neurosurgical system
NASA Astrophysics Data System (ADS)
Shima, Daniel W.; Galloway, Robert L., Jr.
1998-06-01
Stereotactic ultrasound can be incorporated into an interactive, image-guide neurosurgical system by using an optical position sensor to define the location of an intraoperative scanner in physical space. A C-program has been developed that communicates with the OptotrakTM system developed by Northern Digital Inc. to optically track the three-dimensional position and orientation of a fan-shaped area defined with respect to a hand-held probe. (i.e., a virtual B-mode ultrasound fan beam) Volumes of CT and MR head scans from the same patient are registered to a location in physical space using a point-based technique. The coordinates of the virtual fan beam in physical space are continuously calculated and updated on-the-fly. During each program loop, the CT and MR data volumes are reformatted along the same plane and displayed as two fan-shaped images that correspond to the current physical-space location of the virtual fan beam. When the reformatted preoperative tomographic images are eventually paired with a real-time intraoperative ultrasound image, a neurosurgeon will be able to use the unique information of each imaging modality (e.g., the high resolution and tissue contrast of CT and MR and the real-time functionality of ultrasound) in a complementary manner to identify structures in the brain more easily and to guide surgical procedures more effectively.
Curvularia fungi presenting as a large cranial base meningioma: case report.
Singh, Harminder; Irwin, Sibyl; Falowski, Steven; Rosen, Mark; Kenyon, Lawrence; Jungkind, Donald; Evans, James
2008-07-01
Fungal infections are emerging as a growing threat to human health, especially in immunocompromised patients. Candida, Cryptococcus, and Aspergillus are a few of the commonly encountered organisms leading to brain abscesses. In this report, we describe Curvularia geniculata as the causative agent in central nervous system infection. Our review of the literature did not reveal a similar published case of central nervous system infection with this organism. A 35-year-old African-American man presented with obstructive hydrocephalus from a large cranial base lesion. Imaging characteristics on computed tomographic and magnetic resonance imaging scans were consistent with those of a cranial base meningioma. The patient underwent an endoscopic transnasal/transclival approach to the anterior middle cranial base for biopsy and decompression of this lesion. A spindle cell proliferation was observed on frozen section, which favored a diagnosis of meningioma. However, on permanent sections, we identified fungal hyphae with budding. Subsequent biopsies grew Curvularia in fungal cultures. Deoxyribonucleic acid sequencing was used to confirm the identification of the isolate as Curvularia geniculata. Limited data are available for in vitro susceptibility testing of Curvularia, and treatment modalities have not yet been standardized. The prognosis is usually poor. Despite being treated with voriconazole and intravenous amphotericin, this patient progressed to multiorgan failure and ultimately died. This is the first reported case of central nervous system infection by Curvularia geniculata.
Johnson, Jeremy J; Garwe, Tabitha; Raines, Alexander R; Thurman, Joseph B; Carter, Sandra; Bender, Jeffrey S; Albrecht, Roxie M
2013-03-01
Diagnostic laparoscopy (DL) has decreased the rate of nontherapeutic laparotomy for patients suffering from penetrating injuries. We evaluated whether DL similarly lowers the rate of nontherapeutic laparotomy for patients with blunt injuries. All patients undergoing DL over a 10-year period (ie, 2001-2010) in a single level 1 trauma center were classified by the mechanism of injury. Demographic and perioperative data were compared using the Student t and Fisher exact tests. There were 131 patients included, 22 of whom sustained blunt injuries. Patients suffering from blunt injuries were more severely injured (Injury Severity Score 18.0 vs 7.3, P = .0001). The most common indication for DL after blunt injury was a computed tomographic scan concerning for bowel injury (59.1%). The rate of nontherapeutic laparotomy for patients sustaining penetrating vs blunt injury was 1.8% and nil, respectively. DL, when coupled with computed tomographic findings, is an effective tool for the initial management of patients with blunt injuries. Copyright © 2013 Elsevier Inc. All rights reserved.
Zhang, Bin; Gao, Fuping; Wang, Mengjiao; Cao, Xu; Liu, Fei; Wang, Xin; Luo, Jianwen; Wang, Guangzhi; Bai, Jing
2014-01-01
Non-invasive in vivo imaging of diffuse and wide-spread colonization within the lungs, rather than distinct solid primary tumors, is still a challenging work. In this work, a lung colonization mouse model bearing A549 human lung tumor was simultaneously scanned by a dual-modality fluorescence molecular tomography (FMT) and X-ray computed tomography (CT) system in vivo. A two steps method which incorporates CT structural information into the FMT reconstruction procedure is employed to provide concurrent anatomical and functional information. By using the target-specific fluorescence agent, the fluorescence tomographic results show elevated fluorescence intensity deep within the lungs which is colonized with diffuse and wide-spread tumors. The results were confirmed with ex vivo fluorescence reflectance imaging and histological examination of the lung tissues. With FMT reconstruction combined with the CT information, the dual-modality FMT/micro-CT system is expected to offer sensitive and noninvasive imaging of diffuse tumor colonization within the lungs in vivo. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
Brain injury following trial of hypothermia for neonatal hypoxic–ischaemic encephalopathy
Shankaran, Seetha; Barnes, Patrick D; Hintz, Susan R; Laptook, Abbott R; Zaterka-Baxter, Kristin M; McDonald, Scott A; Ehrenkranz, Richard A; Walsh, Michele C; Tyson, Jon E; Donovan, Edward F; Goldberg, Ronald N; Bara, Rebecca; Das, Abhik; Finer, Neil N; Sanchez, Pablo J; Poindexter, Brenda B; Van Meurs, Krisa P; Carlo, Waldemar A; Stoll, Barbara J; Duara, Shahnaz; Guillet, Ronnie; Higgins, Rosemary D
2013-01-01
Objective The objective of our study was to examine the relationship between brain injury and outcome following neonatal hypoxic–ischaemic encephalopathy treated with hypothermia. Design and patients Neonatal MRI scans were evaluated in the National Institute of Child Health and Human Development (NICHD) randomised controlled trial of whole-body hypothermia and each infant was categorised based upon the pattern of brain injury on the MRI findings. Brain injury patterns were assessed as a marker of death or disability at 18–22 months of age. Results Scans were obtained on 136 of 208 trial participants (65%); 73 in the hypothermia and 63 in the control group. Normal scans were noted in 38 of 73 infants (52%) in the hypothermia group and 22 of 63 infants (35%) in the control group. Infants in the hypothermia group had fewer areas of infarction (12%) compared to infants in the control group (22%). Fifty-one of the 136 infants died or had moderate or severe disability at 18 months. The brain injury pattern correlated with outcome of death or disability and with disability among survivors. Each point increase in the severity of the pattern of brain injury was independently associated with a twofold increase in the odds of death or disability. Conclusions Fewer areas of infarction and a trend towards more normal scans were noted in brain MRI following whole-body hypothermia. Presence of the NICHD pattern of brain injury is a marker of death or moderate or severe disability at 18–22 months following hypothermia for neonatal encephalopathy. PMID:23080477
Zhu, Jian; Bai, Tong; Gu, Jiabing; Sun, Ziwen; Wei, Yumei; Li, Baosheng; Yin, Yong
2018-04-27
To evaluate the effect of pretreatment megavoltage computed tomographic (MVCT) scan methodology on setup verification and adaptive dose calculation in helical TomoTherapy. Both anthropomorphic heterogeneous chest and pelvic phantoms were planned with virtual targets by TomoTherapy Physicist Station and were scanned with TomoTherapy megavoltage image-guided radiotherapy (IGRT) system consisted of six groups of options: three different acquisition pitches (APs) of 'fine', 'normal' and 'coarse' were implemented by multiplying 2 different corresponding reconstruction intervals (RIs). In order to mimic patient setup variations, each phantom was shifted 5 mm away manually in three orthogonal directions respectively. The effect of MVCT scan options was analyzed in image quality (CT number and noise), adaptive dose calculation deviations and positional correction variations. MVCT scanning time with pitch of 'fine' was approximately twice of 'normal' and 3 times more than 'coarse' setting, all which will not be affected by different RIs. MVCT with different APs delivered almost identical CT numbers and image noise inside 7 selected regions with various densities. DVH curves from adaptive dose calculation with serial MVCT images acquired by varied pitches overlapped together, where as there are no significant difference in all p values of intercept & slope of emulational spinal cord (p = 0.761 & 0.277), heart (p = 0.984 & 0.978), lungs (p = 0.992 & 0.980), soft tissue (p = 0.319 & 0.951) and bony structures (p = 0.960 & 0.929) between the most elaborated and the roughest serials of MVCT. Furthermore, gamma index analysis shown that, compared to the dose distribution calculated on MVCT of 'fine', only 0.2% or 1.1% of the points analyzed on MVCT of 'normal' or 'coarse' do not meet the defined gamma criterion. On chest phantom, all registration errors larger than 1 mm appeared at superior-inferior axis, which cannot be avoided with the smallest AP and RI. On pelvic phantom, craniocaudal errors are much smaller than chest, however, AP of 'coarse' presents larger registration errors which can be reduced from 2.90 mm to 0.22 mm by registration technique of 'full image'. AP of 'coarse' with RI of 6 mm is recommended in adaptive radiotherapy (ART) planning to provide craniocaudal longer and faster MVCT scan, while registration technique of 'full image' should be used to avoid large residual error. Considering the trade-off between IGRT and ART, AP of 'normal' with RI of 2 mm was highly recommended in daily practice.
A Novel Application for the Cavalieri Principle: A Stereological and Methodological Study
Altunkaynak, Berrin Zuhal; Altunkaynak, Eyup; Unal, Deniz; Unal, Bunyamin
2009-01-01
Objective The Cavalieri principle was applied to consecutive pathology sections that were photographed at the same magnification and used to estimate tissue volumes via superimposing a point counting grid on these images. The goal of this study was to perform the Cavalieri method quickly and practically. Materials and Methods In this study, 10 adult female Sprague Dawley rats were used. Brain tissue was removed and sampled both systematically and randomly. Brain volumes were estimated using two different methods. First, all brain slices were scanned with an HP ScanJet 3400C scanner, and their images were shown on a PC monitor. Brain volume was then calculated based on these images. Second, all brain slices were photographed in 10× magnification with a microscope camera, and brain volumes were estimated based on these micrographs. Results There was no statistically significant difference between the volume measurements of the two techniques (P>0.05; Paired Samples t Test). Conclusion This study demonstrates that personal computer scanning of serial tissue sections allows for easy and reliable volume determination based on the Cavalieri method. PMID:25610077
A novel application for the cavalieri principle: a stereological and methodological study.
Altunkaynak, Berrin Zuhal; Altunkaynak, Eyup; Unal, Deniz; Unal, Bunyamin
2009-08-01
The Cavalieri principle was applied to consecutive pathology sections that were photographed at the same magnification and used to estimate tissue volumes via superimposing a point counting grid on these images. The goal of this study was to perform the Cavalieri method quickly and practically. In this study, 10 adult female Sprague Dawley rats were used. Brain tissue was removed and sampled both systematically and randomly. Brain volumes were estimated using two different methods. First, all brain slices were scanned with an HP ScanJet 3400C scanner, and their images were shown on a PC monitor. Brain volume was then calculated based on these images. Second, all brain slices were photographed in 10× magnification with a microscope camera, and brain volumes were estimated based on these micrographs. There was no statistically significant difference between the volume measurements of the two techniques (P>0.05; Paired Samples t Test). This study demonstrates that personal computer scanning of serial tissue sections allows for easy and reliable volume determination based on the Cavalieri method.
NASA Astrophysics Data System (ADS)
Saeb Gilani, T.; Villringer, C.; Zhang, E.; Gundlach, H.; Buchmann, J.; Schrader, S.; Laufer, J.
2018-02-01
Tomographic photoacoustic (PA) images acquired using a Fabry-Perot (FP) based scanner offer high resolution and image fidelity but can result in long acquisition times due to the need for raster scanning. To reduce the acquisition times, a parallelised camera-based PA signal detection scheme is developed. The scheme is based on using a sCMOScamera and FPI sensors with high homogeneity of optical thickness. PA signals were acquired using the camera-based setup and the signal to noise ratio (SNR) was measured. A comparison of the SNR of PA signal detected using 1) a photodiode in a conventional raster scanning detection scheme and 2) a sCMOS camera in parallelised detection scheme is made. The results show that the parallelised interrogation scheme has the potential to provide high speed PA imaging.
Breast ultrasound tomography with two parallel transducer arrays: preliminary clinical results
NASA Astrophysics Data System (ADS)
Huang, Lianjie; Shin, Junseob; Chen, Ting; Lin, Youzuo; Intrator, Miranda; Hanson, Kenneth; Epstein, Katherine; Sandoval, Daniel; Williamson, Michael
2015-03-01
Ultrasound tomography has great potential to provide quantitative estimations of physical properties of breast tumors for accurate characterization of breast cancer. We design and manufacture a new synthetic-aperture breast ultrasound tomography system with two parallel transducer arrays. The distance of these two transducer arrays is adjustable for scanning breasts with different sizes. The ultrasound transducer arrays are translated vertically to scan the entire breast slice by slice and acquires ultrasound transmission and reflection data for whole-breast ultrasound imaging and tomographic reconstructions. We use the system to acquire patient data at the University of New Mexico Hospital for clinical studies. We present some preliminary imaging results of in vivo patient ultrasound data. Our preliminary clinical imaging results show promising of our breast ultrasound tomography system with two parallel transducer arrays for breast cancer imaging and characterization.
Walther, Paul; Schmid, Eberhard; Höhn, Katharina
2013-01-01
Using an electron microscope's scanning transmission mode (STEM) for collection of tomographic datasets is advantageous compared to bright field transmission electron microscopic (TEM). For image formation, inelastic scattering does not cause chromatic aberration, since in STEM mode no image forming lenses are used after the beam has passed the sample, in contrast to regular TEM. Therefore, thicker samples can be imaged. It has been experimentally demonstrated that STEM is superior to TEM and energy filtered TEM for tomography of samples as thick as 1 μm. Even when using the best electron microscope, adequate sample preparation is the key for interpretable results. We adapted protocols for high-pressure freezing of cultivated cells from a physiological state. In this chapter, we describe optimized high-pressure freezing and freeze substitution protocols for STEM tomography in order to obtain high membrane contrast.
Electron beam machining using rotating and shaped beam power distribution
Elmer, J.W.; O`Brien, D.W.
1996-07-09
An apparatus and method are disclosed for electron beam (EB) machining (drilling, cutting and welding) that uses conventional EB guns, power supplies, and welding machine technology without the need for fast bias pulsing technology. The invention involves a magnetic lensing (EB optics) system and electronic controls to: (1) concurrently bend, focus, shape, scan, and rotate the beam to protect the EB gun and to create a desired effective power-density distribution, and (2) rotate or scan this shaped beam in a controlled way. The shaped beam power-density distribution can be measured using a tomographic imaging system. For example, the EB apparatus of this invention has the ability to drill holes in metal having a diameter up to 1,000 {micro}m (1 mm or larger), compared to the 250 {micro}m diameter of laser drilling. 5 figs.
Craig, J B; Jackson, D V; Moody, D; Cruz, J M; Pope, E K; Powell, B L; Spurr, C L; Capizzi, R L
1984-10-01
Computed cranial tomographic scans were performed as part of the pretreatment evaluation and at six- to nine-month intervals posttreatment in 13 patients with small cell lung carcinoma. All patients received 3,000 rad of prophylactic cranial irradiation delivered over two weeks in ten treatment fractions in conjunction with multiagent chemotherapy. Posttreatment scans documented an extraordinarily high frequency of abnormalities including cerebral atrophy (100%), ventricular dilatation (70%), and decreased coefficient of absorption in the white matter (15%). Unexplained neurologic abnormalities developed in four of six patients living at least 15 months after institution of therapy. As the number of long-term survivors of this type of lung cancer increases, the need for prospective comprehensive neuropsychologic assessment to determine the clinical significance of these changes is needed.
Meng, Yifei; Zuo, Jian-Min
2016-09-01
A diffraction-based technique is developed for the determination of three-dimensional nanostructures. The technique employs high-resolution and low-dose scanning electron nanodiffraction (SEND) to acquire three-dimensional diffraction patterns, with the help of a special sample holder for large-angle rotation. Grains are identified in three-dimensional space based on crystal orientation and on reconstructed dark-field images from the recorded diffraction patterns. Application to a nanocrystalline TiN thin film shows that the three-dimensional morphology of columnar TiN grains of tens of nanometres in diameter can be reconstructed using an algebraic iterative algorithm under specified prior conditions, together with their crystallographic orientations. The principles can be extended to multiphase nanocrystalline materials as well. Thus, the tomographic SEND technique provides an effective and adaptive way of determining three-dimensional nanostructures.
Forthergillian Lecture. Imaging human brain function.
Frackowiak, R S
The non-invasive brain scanning techniques introduced a quarter of a century ago have become crucial for diagnosis in clinical neurology. They have also been used to investigate brain function and have provided information about normal activity and pathogenesis. They have been used to investigate functional specialization in the brain and how specialized areas communicate to generate complex integrated functions such as speech, memory, the emotions and so on. The phenomenon of brain plasticity is poorly understood and yet clinical neurologists are aware, from everyday observations, that spontaneous recovery from brain lesions is common. An improved understanding of the mechanisms of recovery may generate new therapeutic strategies and indicate ways of modulating mechanisms that promote plastic compensation for loss of function. The main methods used to investigate these issues are positron emission tomography and magnetic resonance imaging (M.R.I.). M.R.I. is also used to map brain structure. The techniques of functional brain mapping and computational morphometrics depend on high performance scanners and a validated set of analytic statistical procedures that generate reproducible data and meaningful inferences from brain scanning data. The motor system presents a good paradigm to illustrate advances made by scanning towards an understanding of plasticity at the level of brain areas. The normal motor system is organized in a nested hierarchy. Recovery from paralysis caused by internal capsule strokes involves functional reorganization manifesting itself as changed patterns of activity in the component brain areas of the normal motor system. The pattern of plastic modification depends in part on patterns of residual or disturbed connectivity after brain injury. Therapeutic manipulations in patients with Parkinson's disease using deep brain stimulation, dopaminergic agents or fetal mesencephalic transplantation provide a means to examine mechanisms underpinning plastic change. Other models of plastic change, such as normal visuospatial learning or re-establishing speech comprehension after cochlear implantation in the deaf illustrate how patterns of brain function adapt over time. Limitations of the scanning techniques and prospects for the future are discussed in relation to new developments in the neuroimaging field.
Majewski, Stanislaw [Yorktown, VA; Proffitt, James [Newport News, VA
2011-12-06
A compact, mobile, dedicated SPECT brain imager that can be easily moved to the patient to provide in-situ imaging, especially when the patient cannot be moved to the Nuclear Medicine imaging center. As a result of the widespread availability of single photon labeled biomarkers, the SPECT brain imager can be used in many locations, including remote locations away from medical centers. The SPECT imager improves the detection of gamma emission from the patient's head and neck area with a large field of view. Two identical lightweight gamma imaging detector heads are mounted to a rotating gantry and precisely mechanically co-registered to each other at 180 degrees. A unique imaging algorithm combines the co-registered images from the detector heads and provides several SPECT tomographic reconstructions of the imaged object thereby improving the diagnostic quality especially in the case of imaging requiring higher spatial resolution and sensitivity at the same time.
Castillo-Barnes, Diego; Peis, Ignacio; Martínez-Murcia, Francisco J.; Segovia, Fermín; Illán, Ignacio A.; Górriz, Juan M.; Ramírez, Javier; Salas-Gonzalez, Diego
2017-01-01
A wide range of segmentation approaches assumes that intensity histograms extracted from magnetic resonance images (MRI) have a distribution for each brain tissue that can be modeled by a Gaussian distribution or a mixture of them. Nevertheless, intensity histograms of White Matter and Gray Matter are not symmetric and they exhibit heavy tails. In this work, we present a hidden Markov random field model with expectation maximization (EM-HMRF) modeling the components using the α-stable distribution. The proposed model is a generalization of the widely used EM-HMRF algorithm with Gaussian distributions. We test the α-stable EM-HMRF model in synthetic data and brain MRI data. The proposed methodology presents two main advantages: Firstly, it is more robust to outliers. Secondly, we obtain similar results than using Gaussian when the Gaussian assumption holds. This approach is able to model the spatial dependence between neighboring voxels in tomographic brain MRI. PMID:29209194
Single photon emission tomography using 99mTc-HM-PAO in the investigation of dementia.
Neary, D; Snowden, J S; Shields, R A; Burjan, A W; Northen, B; MacDermott, N; Prescott, M C; Testa, H J
1987-01-01
Single photon emission tomographic imaging of the brain using 99mTc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy. Images PMID:3499484
Split My Brain: A Case Study of Seizure Disorder and Brain Function
ERIC Educational Resources Information Center
Omarzu, Julia
2004-01-01
This case involves a couple deciding whether or not their son should undergo brain surgery to treat a severe seizure disorder. In examining this dilemma, students apply knowledge of brain anatomy and function. They also learn about brain scanning techniques and discuss the plasticity of the brain.
Kimura, Takuma; Aoki, Makoto; Aoki, Yasuko; Tonhyo, Chong
2005-03-01
We report a case of sphenoid sinusitis which could be diagnosed by orbital CT after detecting Strepotococcus pneumoniae from blood culture. A previously healthy 47 year-old Japanese male was admitted to our hospital with severe left-sided headache of 2 days duration. From 9 days before hospitalization (1st day), the patient complained of cough and sputum. On physical examination, his neck was supple and his temperature was 38.3 degrees C. The rest of the examination was normal. A chest radiograph, sinus radiograph, and head computed tomographic (CT) scan without contrast material disclosed no abnormalities. Lumbar puncture was done and cerebrospinal fluid was clear and cell counts and the levels of glucose and protein were normal. The peripheral white blood cell count was 14,400/fl, and the C-reactive protein level was 9.6 mg/dl. After blood, urine, pharyngeal mucus and cerebrospinal fluid cultures were obtained, empirical antibiotic therapy with 2 gms of piperacillin twice daily was begun. He complained sever left-sided retro-orbital headahe on the next day too. The lumbar puncture and head CT scan with contrast material was done again but gave no diagnostic clues. The examinations by the otolaryngologist, ophthalmologist and dentist found no abnormal findings. On the 3rd hospitalized day, Strepotococcus pneumoniae was detected from the blood culture taken on the 1st hospitalized day. A CT scan focused on orbita was done and revealed a low density area of the left sphenoid sinus. The dose of piperacillin was increased to 4 gms twice daily and continued for 24 days. The patient's headache improved and piperacillin was changed to oral levofloxacin 100 mg, three times daily on the 26th day. The medication was stopped on the 73th day. Isolated sphenoid sinusitis is rare, but crtitical complications such as cranial nerve involvement, brain abscess, and bacterial meningitis may happen. It is necessary to also think of sphenoid sinusitis in practices of patients with severe headache.
Bieńko, Marek; Radzki, Radosław Piotr; Wolski, Dariusz
2017-09-21
This study evaluates the effects of three different doses of chromium sulphate on bone density and the tomographic parameters of skeletal tissue of rats. The experiment was performed on 40 male Wistar rats which received, by gavage, during 90 days, a chromium sulphate in either a daily dose of 400, 600 or 800 µg/kg BW. At the end of experiment, the rats were scanned using the densitometry method (DXA) to determine the bone mineral density, bone mineral content of total skeleton and vertebral column (L2-L4) and parameters of body composition (Lean Mass and Fat Mass). The isolated femora were scanned using peripheral a quantitative computed tomography method (pQCT) for a separate analysis of the trabecular and cortical bone tissue. The ultimate strength, work to ultimate and the Young modulus of femora was also investigated by the three-point bending test. The negative impact of chromium was observed in relation to bone tissue. All doses significantly decreased total skeleton density and mineral content, and also had impact upon the isolated femora and vertebral column. Trabecular volumetric bone mineral density and trabecular bone mineral content measured by pQCT in distal femur metaphysis were significantly lower in the experimental groups than in the control. Higher doses of chromium also significantly decreased values of ultimate strength and Young modulus in the investigated femora. The results of the experiment demonstrate that chromium sulphate is dose dependent, and exerts a disadvantageous effect on the skeleton, as it decreases bone density and resistance.
Koukourakis, G; Maravelis, G; Koukouraki, S; Padelakos, P; Kouloulias, V
2009-01-01
The concept of emission and transmission tomography was introduced by David Kuhl and Roy Edwards in the late 1950s. Their work later led to the design and construction of several tomographic instruments at the University of Pennsylvania. Tomographic imaging techniques were further developed by Michel Ter-Pogossian, Michael E. Phelps and others at the Washington University School of Medicine. Positron emission tomography (PET) is a nuclear medicine imaging technique which produces a 3-dimensional image or map of functional processes in the body. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule. Images of tracer concentration in 3-dimensional space within the body are then reconstructed by computer analysis. In modern scanners, this reconstruction is often accomplished with the aid of a CT X-ray scan performed on the patient during the same session, in the same machine. If the biologically active molecule chosen for PET is 18F-fluorodeoxyglucose (FDG), an analogue of glucose, the concentrations of tracer imaged give tissue metabolic activity in terms of regional glucose uptake. Although use of this tracer results in the most common type of PET scan, other tracer molecules are used in PET to image the tissue concentration of many other types of molecules of interest. The main role of this article was to analyse the available types of radiopharmaceuticals used in PET-CT along with the principles of its clinical and technical considerations.
Wang, Guangli; Zhang, Chengqi; Li, Mingying; Deng, Kai; Li, Wei
2014-01-01
To evaluate the feasibility of multiparameter quantitative measurement lung cancer by Gemstone Spectral Imaging (GSI) high-definition computed tomography. Seventy-seven patients who were found to have a lung mass or a nodule by CT plain scan for the first time received chest contrast CT scan with GSI mode on high-definition computed tomography. The GSI viewer was used to display the spectral curve, iodine-based images, water-based images, and 101 sets of monochromatic images of a selected region of interest from the relative homogeneous area of the mass or nodule. Iodine concentration, water concentration, spectral curve slope, and CT values at 40 keV of the region of interest were measured. Finally, 68 eligible patients were divided into a pneumonia group (n = 24) and a malignant tumor group (n = 44, including squamous carcinoma, n = 29, and adenocarcinoma, n = 15). Significant differences existed in iodine concentration (t = 6.459), spectral curve slope (t = 6.276), and CT values at 40 keV (t = 6.698) between the pneumonia group and the malignant tumor group (P < 0.05), as well as between squamous carcinoma and adenocarcinoma (t = 6.494, 5.634, 6.091, respectively, P < 0.05), whereas water concentrations were found to have no difference between the 2 groups (t = 0.082, P > 0.05) and between the 2 types of malignant tumors (t = 1.234, P > 0.05). High-definition computed tomographic GSI technique might be helpful to differentiate lung cancer from lung benign lesions by providing qualitative and quantitative information.
Subphrenic and Pleural Abscess Due to Spilled Gallstones
Varker, Kimberly A.; Zaydfudim, Victor; McKee, Jason
2006-01-01
Background: A 70-year-old male approximately 3 years after laparoscopic cholecystectomy presented to his primary care physician with a 4-month history of generalized malaise. Methods: A workup included magnetic resonance imaging that revealed a perihepatic abscess. The patient underwent ultrasound-guided drainage, with the removal of 1400 mL of purulent fluid and placement of 2 drains. Computed tomographic scanning showed resolution, and he was discharged home on oral antibiotics. At 2-month follow-up, the patient was asymptomatic, denying any constitutional symptoms. However, abdominal computed tomographic scanning revealed recurrence of the abscess, which measured approximately 18x9x7.5 cm, with mass effect on the liver. The patient was placed on intravenous antibiotics and scheduled for operative drainage. The abdomen was entered with a right subcostal incision, and 900 mL of purulent fluid was drained. We also noted abscess erosion through the inferolateral aspect of the right diaphragm into the pleural space. The pleural abscess was loculated and isolated from the lung parenchyma. Palpation within the abscess cavity revealed 9 large gallstones. Following copious irrigation and debridement of necrotic tissue, 3 drains were placed and the incision was closed. Results: The patient had an uneventful recovery and was discharged home on postoperative day number 6. Follow-up imaging at 3 months demonstrated resolution of the collection. Conclusion: Spillage of gallstones is a complication of laparoscopic cholecystectomy, occurring in 6% to 16% of all cases. Retained stones rarely result in a problem, but when complications arise, aggressive surgical intervention is usually necessary. PMID:16709371
Thoracic textilomas: CT findings*
Machado, Dianne Melo; Zanetti, Gláucia; Araujo, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Pereira e Silva, Jorge Luiz; Guimarães, Marcos Duarte; Escuissato, Dante Luiz; Souza, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson
2014-01-01
OBJECTIVE: The aim of this study was to analyze chest CT scans of patients with thoracic textiloma. METHODS: This was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. RESULTS: The majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). CONCLUSIONS: It is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. PMID:25410842
Determination of the position of nucleus cochlear implant electrodes in the inner ear.
Skinner, M W; Ketten, D R; Vannier, M W; Gates, G A; Yoffie, R L; Kalender, W A
1994-09-01
Accurate determination of intracochlear electrode position in patients with cochlear implants could provide a basis for detecting migration of the implant and could aid in the selection of stimulation parameters for sound processor programming. New computer algorithms for submillimeter resolution and 3-D reconstruction from spiral computed tomographic (CT) scans now make it possible to accurately determine the position of implanted electrodes within the cochlear canal. The accuracy of these algorithms was tested using an electrode array placed in a phantom model. Measurements of electrode length and interelectrode distance from spiral CT scan reconstructions were in close agreement with those from stereo microscopy. Although apparent electrode width was increased on CT scans due to partial volume averaging, a correction factor was developed for measurements from conventional radiographs and an expanded CT absorption value scale added to detect the presence of platinum electrodes and wires. The length of the cochlear canal was calculated from preoperative spiral CT scans for one patient, and the length of insertion of the electrode array was calculated from her postoperative spiral CT scans. The cross-sectional position of electrodes in relation to the outer bony wall and modiolus was measured and plotted as a function of distance with the electrode width correction applied.
Feasibility study: real-time 3-D ultrasound imaging of the brain.
Smith, Stephen W; Chu, Kengyeh; Idriss, Salim F; Ivancevich, Nikolas M; Light, Edward D; Wolf, Patrick D
2004-10-01
We tested the feasibility of real-time, 3-D ultrasound (US) imaging in the brain. The 3-D scanner uses a matrix phased-array transducer of 512 transmit channels and 256 receive channels operating at 2.5 MHz with a 15-mm diameter footprint. The real-time system scans a 65 degrees pyramid, producing up to 30 volumetric scans per second, and features up to five image planes as well as 3-D rendering, 3-D pulsed-wave and color Doppler. In a human subject, the real-time 3-D scans produced simultaneous transcranial horizontal (axial), coronal and sagittal image planes and real-time volume-rendered images of the gross anatomy of the brain. In a transcranial sheep model, we obtained real-time 3-D color flow Doppler scans and perfusion images using bolus injection of contrast agents into the internal carotid artery.
Newberg, Andrew B; Serruya, Mijail; Gepty, Andrew; Intenzo, Charles; Lewis, Todd; Amen, Daniel; Russell, David S; Wintering, Nancy
2014-01-01
This study evaluated the clinical interpretations of single photon emission computed tomography (SPECT) using a cerebral blood flow and a dopamine transporter tracer in patients with chronic mild traumatic brain injury (TBI). The goal was to determine how these two different scan might be used and compared to each other in this patient population. Twenty-five patients with persistent symptoms after a mild TBI underwent SPECT with both (99m)Tc exametazime to measure cerebral blood flow (CBF) and (123)I ioflupane to measure dopamine transporter (DAT) binding. The scans were interpreted by two expert readers blinded to any case information and were assessed for abnormal findings in comparison to 10 controls for each type of scan. Qualitative CBF scores for each cortical and subcortical region along with DAT binding scores for the striatum were compared to each other across subjects and to controls. In addition, symptoms were compared to brain scan findings. TBI patients had an average of 6 brain regions with abnormal perfusion compared to controls who had an average of 2 abnormal regions (p<0.001). Patient with headaches had lower CBF in the right frontal lobe, and higher CBF in the left parietal lobe compared to patients without headaches. Lower CBF in the right temporal lobe correlated with poorer reported physical health. Higher DAT binding was associated with more depressive symptoms and overall poorer reported mental health. There was no clear association between CBF and DAT binding in these patients. Overall, both scans detected abnormalities in brain function, but appear to reflect different types of physiological processes associated with chronic mild TBI symptoms. Both types of scans might have distinct uses in the evaluation of chronic TBI patients depending on the clinical scenario.
Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Syouichi; Koshida, Kichiro; Matsunaga, Yuta; Kawaguchi, Ai; Haba, Tomonobu; Toyama, Hiroshi; Kato, Ryouichi
2017-05-01
We developed a k-factor-creator software (kFC) that provides the k-factor for CT examination in an arbitrary scan area. It provides the k-factor from the effective dose and dose-length product by Imaging Performance Assessment of CT scanners and CT-EXPO. To assess the reliability, we compared the kFC-evaluated k-factors with those of the International Commission on Radiological Protection (ICRP) publication 102. To confirm the utility, the effective dose determined by coronary computed tomographic angiography (CCTA) was evaluated by a phantom study and k-factor studies. In the CCTA, the effective doses were 5.28 mSv in the phantom study, 2.57 mSv (51%) in the k-factor of ICRP, and 5.26 mSv (1%) in the k-factor of the kFC. Effective doses can be determined from the kFC-evaluated k-factors in suitable scan areas. Therefore, we speculate that the flexible k-factor is useful in clinical practice, because CT examinations are performed in various scan regions. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Photoacoustic imaging to detect rat brain activation after cocaine hydrochloride injection
NASA Astrophysics Data System (ADS)
Jo, Janggun; Yang, Xinmai
2011-03-01
Photoacoustic imaging (PAI) was employed to detect small animal brain activation after the administration of cocaine hydrochloride. Sprague Dawley rats were injected with different concentrations (2.5, 3.0, and 5.0 mg per kg body) of cocaine hydrochloride in saline solution through tail veins. The brain functional response to the injection was monitored by photoacoustic tomography (PAT) system with horizontal scanning of cerebral cortex of rat brain. Photoacoustic microscopy (PAM) was also used for coronal view images. The modified PAT system used multiple ultrasonic detectors to reduce the scanning time and maintain a good signal-to-noise ratio (SNR). The measured photoacoustic signal changes confirmed that cocaine hydrochloride injection excited high blood volume in brain. This result shows PAI can be used to monitor drug abuse-induced brain activation.
Nakajima, Reiko; Abe, Koichiro; Momose, Mitsuru; Fukushima, Kenji; Matsuo, Yuka; Kimura, Ken; Kondo, Chisato; Sakai, Shuji
2017-02-01
11 C-Methionine (MET) positron emission tomography (PET) imaging is a valuable technique for the evaluation of primary and recurrent brain tumors. Many studies have used MET-PET for data acquisition starting at 20 min after the tracer injection, while others have used scan initiation times at 5-15 min postinjection. No previous studies have identified the best acquisition timing during MET-PET imaging for suspected recurrent brain tumors. Here we sought to determine the optimal scan initiating timing after MET administration for the detection of recurrent brain tumors. Twenty-three consecutive patients with suspected recurrent brain tumors underwent MET-PET examinations. Brain PET images were reconstructed from the four serial data sets (10-15, 15-20, 20-25, and 25-30 min postinjection) that were obtained using the list-mode acquisition technique. We determined the maximal standardized uptake values (SUVmax) of the target lesions and the target-to-normal-tissue ratios (TNRs), calculated as the SUVmax to the SUVmean of a region of interest placed on the normal contralateral frontal cortex. Target lesions without significant MET uptake were excluded. Thirty-one lesions from 23 patients were enrolled. There were no significant differences in MET SUVmax or TNR values among the PET images that were reconstructed with the data extracted from the four phases postinjection. The MET uptake in the suspected recurrent brain tumors was comparable among all data extraction time phases from 10 to 30 min postinjection. The scan initiation time of MET-PET at 10 min after the injection is allowable for the detection of recurrent brain tumors. The registration identification number of the original study is 1002.
Shokouhi, Sepideh; Rogers, Baxter P; Kang, Hakmook; Ding, Zhaohua; Claassen, Daniel O; Mckay, John W; Riddle, William R
2015-01-01
Amyloid-beta (Aβ) imaging with positron emission tomography (PET) holds promise for detecting the presence of Aβ plaques in the cortical gray matter. Many image analyses focus on regional average measurements of tracer activity distribution; however, considerable additional information is available in the images. Metrics that describe the statistical properties of images, such as the two-point correlation function (S2), have found wide applications in astronomy and materials science. S2 provides a detailed characterization of spatial patterns in images typically referred to as clustering or flocculence. The objective of this study was to translate the two-point correlation method into Aβ-PET of the human brain using 11C-Pittsburgh compound B (11C-PiB) to characterize longitudinal changes in the tracer distribution that may reflect changes in Aβ plaque accumulation. We modified the conventional S2 metric, which is primarily used for binary images and formulated a weighted two-point correlation function (wS2) to describe nonbinary, real-valued PET images with a single statistical function. Using serial 11C-PiB scans, we calculated wS2 functions from two-dimensional PET images of different cortical regions as well as three-dimensional data from the whole brain. The area under the wS2 functions was calculated and compared with the mean/median of the standardized uptake value ratio (SUVR). For three-dimensional data, we compared the area under the wS2 curves with the subjects' cerebrospinal fluid measures. Overall, the longitudinal changes in wS2 correlated with the increase in mean SUVR but showed lower variance. The whole brain results showed a higher inverse correlation between the cerebrospinal Aβ and wS2 than between the cerebrospinal Aβ and SUVR mean/median. We did not observe any confounding of wS2 by region size or injected dose. The wS2 detects subtle changes and provides additional information about the binding characteristics of radiotracers and Aβ accumulation that are difficult to verify with mean SUVR alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yi, B; Hu, E; Yu, C
2015-06-15
Purpose: A Tomo-Cinegraphy (TC) is a method to generate a series of temporal tomographic images from projection images of the on-board imager (OBI) while gantry is moving. It is to test if this technique is useful to determine a lung tumor position during treatments. Methods: Tomographic image via background subtraction, TIBS uses a priori anatomical information from a previous CT scan to isolate a SOI from a planar kV image by factoring out the attenuations by tissues outside the SOI (background). This idea was extended to a TC, which enables to generate tomographic images of same geometry from the projectionmore » of different gantry angles and different breathing phases. Projection images of a lung patient for CBCT acquisition are used to generate TC images. A region of interest (ROI) is selected around a tumor adding 2cm margins. Center of mass (COM) of the ROI is traced to determine tumor position for every projection images. Results: Tumor is visible in the TC images while the OBI projections are not. The coordinates of the COMs represent the temporal tumor positions. While, it is not possible to trace the tumor motion using the projection images. A source of time delay is the time to acquire projection images, which is always less than a second. Conclusion: TC allows tracking the tumor positions without fiducial markers in real time for some lung patients, if the projection images are acquired during treatments. Partially supported by NIH R01CA133539.« less
Validated Automatic Brain Extraction of Head CT Images
Muschelli, John; Ullman, Natalie L.; Mould, W. Andrew; Vespa, Paul; Hanley, Daniel F.; Crainiceanu, Ciprian M.
2015-01-01
Background X-ray Computed Tomography (CT) imaging of the brain is commonly used in diagnostic settings. Although CT scans are primarily used in clinical practice, they are increasingly used in research. A fundamental processing step in brain imaging research is brain extraction – the process of separating the brain tissue from all other tissues. Methods for brain extraction have either been 1) validated but not fully automated, or 2) fully automated and informally proposed, but never formally validated. Aim To systematically analyze and validate the performance of FSL's brain extraction tool (BET) on head CT images of patients with intracranial hemorrhage. This was done by comparing the manual gold standard with the results of several versions of automatic brain extraction and by estimating the reliability of automated segmentation of longitudinal scans. The effects of the choice of BET parameters and data smoothing is studied and reported. Methods All images were thresholded using a 0 – 100 Hounsfield units (HU) range. In one variant of the pipeline, data were smoothed using a 3-dimensional Gaussian kernel (σ = 1mm3) and re-thresholded to 0 – 100 HU; in the other, data were not smoothed. BET was applied using 1 of 3 fractional intensity (FI) thresholds: 0.01, 0.1, or 0.35 and any holes in the brain mask were filled. For validation against a manual segmentation, 36 images from patients with intracranial hemorrhage were selected from 19 different centers from the MISTIE (Minimally Invasive Surgery plus recombinant-tissue plasminogen activator for Intracerebral Evacuation) stroke trial. Intracranial masks of the brain were manually created by one expert CT reader. The resulting brain tissue masks were quantitatively compared to the manual segmentations using sensitivity, specificity, accuracy, and the Dice Similarity Index (DSI). Brain extraction performance across smoothing and FI thresholds was compared using the Wilcoxon signed-rank test. The intracranial volume (ICV) of each scan was estimated by multiplying the number of voxels in the brain mask by the dimensions of each voxel for that scan. From this, we calculated the ICV ratio comparing manual and automated segmentation: ICVautomatedICVmanual. To estimate the performance in a large number of scans, brain masks were generated from the 6 BET pipelines for 1095 longitudinal scans from 129 patients. Failure rates were estimated from visual inspection. ICV of each scan was estimated and and an intraclass correlation (ICC) was estimated using a one-way ANOVA. Results Smoothing images improves brain extraction results using BET for all measures except specificity (all p < 0.01, uncorrected), irrespective of the FI threshold. Using an FI of 0.01 or 0.1 performed better than 0.35. Thus, all reported results refer only to smoothed data using an FI of 0.01 or 0.1. Using an FI of 0.01 had a higher median sensitivity (0.9901) than an FI of 0.1 (0.9884, median difference: 0.0014, p < 0.001), accuracy (0.9971 vs. 0.9971; median difference: 0.0001, p < 0.001), and DSI (0.9895 vs. 0.9894; median difference: 0.0004, p < 0.001) and lower specificity (0.9981 vs. 0.9982; median difference: −0.0001, p < 0.001). These measures are all very high indicating that a range of FI values may produce visually indistinguishable brain extractions. Using smoothed data and an FI of 0.01, the mean (SD) ICV ratio was 1.002 (0.008); the mean being close to 1 indicates the ICV estimates are similar for automated and manual segmentation. In the 1095 longitudinal scans, this pipeline had a low failure rate (5.2%) and the ICC estimate was high (0.929, 95% CI: 0.91, 0.945) for successfully extracted brains. Conclusion BET performs well at brain extraction on thresholded, 1mm3 smoothed CT images with an FI of 0.01 or 0.1. Smoothing before applying BET is an important step not previously discussed in the literature. Analysis code is provided. PMID:25862260
Almeida-Corrêa, Suellen; Czisch, Michael; Wotjak, Carsten T
2018-01-01
Manganese-enhanced magnetic resonance imaging (MEMRI) is a powerful tool for in vivo non-invasive whole-brain mapping of neuronal activity. Mn 2+ enters active neurons via voltage-gated calcium channels and increases local contrast in T 1 -weighted images. Given the property of Mn 2+ of axonal transport, this technique can also be used for tract tracing after local administration of the contrast agent. However, MEMRI is still not widely employed in basic research due to the lack of a complete description of the Mn 2+ dynamics in the brain. Here, we sought to investigate how the activity state of neurons modulates interneuronal Mn 2+ transport. To this end, we injected mice with low dose MnCl 2 2. (i.p., 20 mg/kg; repeatedly for 8 days) followed by two MEMRI scans at an interval of 1 week without further MnCl 2 injections. We assessed changes in T 1 contrast intensity before (scan 1) and after (scan 2) partial sensory deprivation (unilateral whisker trimming), while keeping the animals in a sensory enriched environment. After correcting for the general decay in Mn 2+ content, whole brain analysis revealed a single cluster with higher signal in scan 1 compared to scan 2: the left barrel cortex corresponding to the right untrimmed whiskers. In the inverse contrast (scan 2 > scan 1), a number of brain structures, including many efferents of the left barrel cortex were observed. These results suggest that continuous neuronal activity elicited by ongoing sensory stimulation accelerates Mn 2+ transport from the uptake site to its projection terminals, while the blockage of sensory-input and the resulting decrease in neuronal activity attenuates Mn 2+ transport. The description of this critical property of Mn 2+ dynamics in the brain allows a better understanding of MEMRI functional mechanisms, which will lead to more carefully designed experiments and clearer interpretation of the results.
Preboske, Gregory M; Gunter, Jeff L; Ward, Chadwick P; Jack, Clifford R
2006-05-01
Measuring rates of brain atrophy from serial magnetic resonance imaging (MRI) studies is an attractive way to assess disease progression in neurodegenerative disorders, particularly Alzheimer's disease (AD). A widely recognized approach is the boundary shift integral (BSI). The objective of this study was to evaluate how several common scan non-idealities affect the output of the BSI algorithm. We created three types of image non-idealities between the image volumes in a serial pair used to measure between-scan change: inconsistent image contrast between serial scans, head motion, and poor signal-to-noise (SNR). In theory the BSI volume difference measured between each pair of images should be zero and any deviation from zero should represent corruption of the BSI measurement by some non-ideality intentionally introduced into the second scan in the pair. Two different BSI measures were evaluated, whole brain and ventricle. As the severity of motion, noise, and non-congruent image contrast increased in the second scan, the calculated BSI values deviated progressively more from the expected value of zero. This study illustrates the magnitude of the error in measures of change in brain and ventricle volume across serial MRI scans that can result from commonly encountered deviations from ideal image quality. The magnitudes of some of the measurement errors seen in this study exceed the disease effect in AD shown in various publications, which range from 1% to 2.78% per year for whole brain atrophy and 5.4% to 13.8% per year for ventricle expansion (Table 1). For example, measurement error may exceed 100% if image contrast properties dramatically differ between the two scans in a measurement pair. Methods to maximize consistency of image quality over time are an essential component of any quantitative serial MRI study.
Sidhu, Deepinder S; Ruth, Jeffrey D; Lambert, Gregory; Rossmeisl, John H
2017-07-01
To develop and validate a three-dimensional (3D) brain phantom that can be incorporated into existing stereotactic headframes to simulate stereotactic brain biopsy (SBB) and train veterinary surgeons. Experimental study. Canine brain phantoms were fabricated from osteological skull specimens, agarose brain parenchyma, and cheddar and mozzarella cheese molds (simulating meningiomas and gliomas). The neuroradiologic and viscoelastic properties of phantoms were quantified with computed tomography (CT) and oscillatory compression tests, respectively. Phantoms were validated by experienced and novice operators performing SBB on phantoms containing randomly placed, focal targets. Target yield and needle placement error (NPE) were compared between operators. Phantoms were produced in <4 hours, at an average cost of $92. The CT appearances of the phantom skull, agarose, and cheese components approximated the in vivo features of skull, brain parenchyma, and contrast-enhancing tumors of meningeal and glial origin, respectively. The complex moduli of the agarose and cheeses were comparable to the viscoelastic properties of in vivo brain tissues and brain tumors. The overall diagnostic yield of SBB was 88%. Although NPE did not differ between novice (median 3.68 mm; range, 1.46-14.54 mm) and experienced surgeons (median 1.17 mm, range, 0.78-1.58 mm), our results support the relevance of the learning curve associated with the SBB procedure. This 3D phantom replicates anatomical, CT, and tactile features of brain tissues and tumors and can be used to develop the technical skills required to perform SBB. © 2017 The American College of Veterinary Surgeons.
Diagnostic Value of 68Ga PSMA-11 PET/CT Imaging of Brain Tumors-Preliminary Analysis.
Sasikumar, Arun; Joy, Ajith; Pillai, M R A; Nanabala, Raviteja; Anees K, Muhammed; Jayaprakash, P G; Madhavan, Jayaprakash; Nair, Suresh
2017-01-01
To evaluate the feasibility of using Ga PSMA-11 PET/CT for imaging brain lesions and its comparison with F-FDG. Ten patients with brain lesions were included in the study. Five patients were treated cases of glioblastoma with suspected recurrence. F-FDG and Ga PSMA-11 brain scans were done for these patients. Five patients were sent for assessing the nature (primary lesion/metastasis) of space occupying lesion in brain. They underwent whole body F-FDG PET/CT scan and a primary site elsewhere in the body was ruled out. Subsequently they underwent Ga PSMA-11 brain PET/CT imaging. Target to background ratios (TBR) for the brain lesions were calculated using contralateral cerebellar uptake as background. In five treated cases of glioblastoma with suspected recurrence the findings of Ga PSMA-11 PET/CT showed good correlation with that of F-FDG PET/CT scan. Compared to the F-FDG, Ga PSMA-11 PET/CT showed better visualization of the recurrent lesion (presence/absence) owing to its significantly high TBR. Among the five cases evaluated for lesion characterization glioma and atypical meningioma patients showed higher SUVmax in the lesion with Ga PSMA-11 than with F-FDG and converse in cases of lymphoma. TBR was better with Ga PSMA PET/CT in all cases. Ga PSMA-11 PET/CT brain imaging is a potentially useful imaging tool in the evaluation of brain lesions. Absence of physiological uptake of Ga PSMA-11 in the normal brain parenchyma results in high TBR values and consequently better visualization of metabolically active disease in brain.
Holmes, Avram J.; Hollinshead, Marisa O.; O’Keefe, Timothy M.; Petrov, Victor I.; Fariello, Gabriele R.; Wald, Lawrence L.; Fischl, Bruce; Rosen, Bruce R.; Mair, Ross W.; Roffman, Joshua L.; Smoller, Jordan W.; Buckner, Randy L.
2015-01-01
The goal of the Brain Genomics Superstruct Project (GSP) is to enable large-scale exploration of the links between brain function, behavior, and ultimately genetic variation. To provide the broader scientific community data to probe these associations, a repository of structural and functional magnetic resonance imaging (MRI) scans linked to genetic information was constructed from a sample of healthy individuals. The initial release, detailed in the present manuscript, encompasses quality screened cross-sectional data from 1,570 participants ages 18 to 35 years who were scanned with MRI and completed demographic and health questionnaires. Personality and cognitive measures were obtained on a subset of participants. Each dataset contains a T1-weighted structural MRI scan and either one (n=1,570) or two (n=1,139) resting state functional MRI scans. Test-retest reliability datasets are included from 69 participants scanned within six months of their initial visit. For the majority of participants self-report behavioral and cognitive measures are included (n=926 and n=892 respectively). Analyses of data quality, structure, function, personality, and cognition are presented to demonstrate the dataset’s utility. PMID:26175908
Holmes, Avram J; Hollinshead, Marisa O; O'Keefe, Timothy M; Petrov, Victor I; Fariello, Gabriele R; Wald, Lawrence L; Fischl, Bruce; Rosen, Bruce R; Mair, Ross W; Roffman, Joshua L; Smoller, Jordan W; Buckner, Randy L
2015-01-01
The goal of the Brain Genomics Superstruct Project (GSP) is to enable large-scale exploration of the links between brain function, behavior, and ultimately genetic variation. To provide the broader scientific community data to probe these associations, a repository of structural and functional magnetic resonance imaging (MRI) scans linked to genetic information was constructed from a sample of healthy individuals. The initial release, detailed in the present manuscript, encompasses quality screened cross-sectional data from 1,570 participants ages 18 to 35 years who were scanned with MRI and completed demographic and health questionnaires. Personality and cognitive measures were obtained on a subset of participants. Each dataset contains a T1-weighted structural MRI scan and either one (n=1,570) or two (n=1,139) resting state functional MRI scans. Test-retest reliability datasets are included from 69 participants scanned within six months of their initial visit. For the majority of participants self-report behavioral and cognitive measures are included (n=926 and n=892 respectively). Analyses of data quality, structure, function, personality, and cognition are presented to demonstrate the dataset's utility.
Wavelength scanning digital interference holography for high-resolution ophthalmic imaging
NASA Astrophysics Data System (ADS)
Potcoava, Mariana C.; Kim, M. K.; Kay, Christine N.
2009-02-01
An improved digital interference holography (DIH) technique suitable for fundus images is proposed. This technique incorporates a dispersion compensation algorithm to compensate for the unknown axial length of the eye. Using this instrument we acquired successfully tomographic fundus images in human eye with narrow axial resolution less than 5μm. The optic nerve head together with the surrounding retinal vasculature were constructed. We were able to quantify a depth of 84μm between the retinal fiber and the retinal pigmented epithelium layers. DIH provides high resolution 3D information which could potentially aid in guiding glaucoma diagnosis and treatment.
2013-09-01
around the AuNR. This is illustrated in Figure 3, which compi!res brightfield,scanningTEM ( STEM ), and 3D tomographic reconstruction of QD,/AuNR. The...distribution unlimited ... Cll u 1 Q. II) QDn/AuNR 1-5 6-10 11-15 16-20 >20 ~ 60 c ~ "’ 40 ..Q ·~ u; c 20 k 2 3 >4 QDn/AuNR Figure 2...showing three-dimensional arrangement of the QOs around the AuNR. (e-i) Elemental mapping from STEM image of silica coated QD·AuNR architecture (e)(scale
Synchrotron radiation microtomography of Taylor bubbles in capillary two-phase flow
NASA Astrophysics Data System (ADS)
Boden, Stephan; dos Santos Rolo, Tomy; Baumbach, Tilo; Hampel, Uwe
2014-07-01
We report on a study to measure the three-dimensional shape of Taylor bubbles in capillaries using synchrotron radiation in conjunction with ultrafast radiographic imaging. Moving Taylor bubbles in 2-mm round and square capillaries were radiographically scanned with an ultrahigh frame rate of up to 36,000 fps and 5.6-µm pixel separation. Consecutive images were properly processed to yield 2D transmission radiographs of high contrast-to-noise ratio. Application of 3D tomographic image reconstruction disclosed the 3D bubble shape. The results provide a reference data base for development of sophisticated interface resolving CFD computations.
Lane, J.W.; Day-Lewis, F. D.; Harris, J.M.; Haeni, F.P.; Gorelick, S.M.
2000-01-01
Attenuation-difference, borehole-radar tomography was used to monitor a series of sodium chloride tracer injection tests conducted within the FSE, wellfield at the U.S. Geological Survey Fractured-Rock Hydrology Research Site in Grafton County, New Hampshire, USA. Borehole-radar tomography surveys were conducted using the sequential-scanning and injection method in three boreholes that form a triangular prism of adjoining tomographic image planes. Results indicate that time-lapse tomography methods provide high-resolution images of tracer distribution in permeable zones.
[Unfixed Mesh Plug Migration from Inguinal Ring to Urinary Bladder].
Okada, Koichi; Nakayama, Jiro; Adachi, Shiro; Miyake, Osamu
2018-02-01
A 65-year-old man presented to a clinic with a chief complaint of macrohematuria and frequent urination. The computed tomographic scan and cystoscopy revealed a dome of bladder tumor. He was referred to our hospital with the diagnosis of bladder tumor. He had undergone bilateral inguinal hernia repair and magnetic resonance imaging suggested mesh plug migration on the urinary bladder inserted into the right inguinal lesion 11 years previously. Under the diagnosis of mesh plug migration, partial cystectomy with extraction of the foreign body was performed. After the surgery he was well and symptoms had disappeared.
Posnick, J C; Bortoluzzi, P; Armstrong, D C
1994-05-01
Midline nasal dermoid cysts are congenital lesions resulting from aberrant embryological development. Accurate diagnosis and effective treatment are essential to avoid craniofacial skeletal deformations, cyst rupture, and infection that could cause cutaneous, ocular, or intracranial complications. We report an unusual case of congenital midline nasal dermoid cysts in which an 18-month-old child presented to a hospital emergency department with periorbital cellulitis. It resulted from multiple midline nasal dermoid cysts involving the nasal, forehead, and both orbital regions but without intracranial extension. The patient was successfully managed with a craniofacial approach.
Battaglia, Salvatore; Maiolo, Vincenzo; Savastio, Gabriella; Zompatori, Maurizio; Contedini, Federico; Antoniazzi, Elisa; Cipriani, Riccardo; Marchetti, Claudio; Tarsitano, Achille
2017-10-01
Mandibular reconstruction performed after virtual planning has become more common during recent years. The gold standard for extensive mandibular reconstruction is of course a fibular free flap. In designing an osteomyocutaneous fibula flap, poor planning, aberrant anatomy and/or inadequate perforator vessels are the most frequent causes of complications and may force the surgeon to modify the flap design, explore the contralateral leg or harvest an additional microvascular flap. The goal of our study was to pre-operatively evaluate the vascular anatomy of the fibula and localize the cutaneous perforator vessels, so to create the fibular cutting guide based on the position of the cutaneous perforator and safely harvest the reconstructive flap. Twenty consecutive patients who were candidates for mandibular reconstruction using a fibular microvascular free flap were enrolled in this study between January 2016 and August 2016. The patients were preoperatively assessed with a Computed Tomographic scan of head and neck and with a Computed Tomographic Angiography (CTA) scan of the lower limbs to evaluate the vascular anatomy of the fibula. Virtual planning was carried out for all patients. The fibular cutting guide was based on the position of the perforator cutaneous vessels, which were used to harvest the cutaneous part of the flap. Preoperative CT measurements were performed in order to identify the cutaneous perforators on the patients' skin. Intraoperative checking was performed to evaluate the accuracy of the perforators' position and the reproducibility of the virtual planning. In 5 patients out of 20 (25%), anatomical anomalies were discovered, without clinical evidence. The perforator vessels were localized in all patients. The average difference between the CTA and the intraoperative perforator localization was 1 mm (range 0-2 mm). Fibular cutting guide was positioned and fitted the anatomy of the patients in all treated patients. This allowed us to perform the planned segmentation of the fibula, obtaining the correct number of segments. In all cases, flap insetting was carried out and skin paddle was positioned as preoperatively planned. Neither donor site complications nor flap complications occurred. Preoperative evaluation of the legs using CTA, in patients who undergo an osteomyocutaneous fibular free flap for mandibular reconstruction, is a valuable approach to reduce altered-anatomy related complications and to improve the accuracy and outcomes of the reconstruction, especially in reconstructions of complex defects. In these cases, a soft tissue-based cutting guide can be planned based on the perforator vessels of the skin paddle, minimizing the harvesting risks of vascular lesions. Further studies and longer follow-ups are needed to evaluate the long-term outcomes and advantages of this procedure. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Somasundaram, Karuppanagounder; Ezhilarasan, Kamalanathan
2015-01-01
To develop an automatic skull stripping method for magnetic resonance imaging (MRI) of human head scans. The proposed method is based on gray scale transformation and morphological operations. The proposed method has been tested with 20 volumes of normal T1-weighted images taken from Internet Brain Segmentation Repository. Experimental results show that the proposed method gives better results than the popular skull stripping methods Brain Extraction Tool and Brain Surface Extractor. The average value of Jaccard and Dice coefficients are 0.93 and 0.962 respectively. In this article, we have proposed a novel skull stripping method using intensity transformation and morphological operations. This is a low computational complexity method but gives competitive or better results than that of the popular skull stripping methods Brain Surface Extractor and Brain Extraction Tool.
Servello, Domenico; Zekaj, Edvin; Saleh, Christian; Pacchetti, Claudio; Porta, Mauro
2016-01-01
Background: Deep brain stimulation (DBS) is an established therapy for movement disorders, such as Parkinson's disease (PD), dystonia, and tremor. The efficacy of DBS depends on the correct lead positioning. The commonly adopted postoperative radiological evaluation is performed with computed tomography (CT) scan and/or magnetic resonance imaging (MRI). Methods: We conducted a retrospective study on 202 patients who underwent DBS from January 2009 to October 2013. DBS indications were PD, progressive supranuclear palsy, tremor, dystonia, Tourette syndrome, obsessive compulsive disorder, depression, and Huntington's disease. Preoperatively, all patients underwent brain MRI and brain CT scan with the stereotactic frame positioned. The lead location was confirmed intraoperatively with CT. The CT images were subsequently transferred to the Stealth Station Medtronic and merged with the preoperative planning. On the first or second day after, implantation we performed a brain MRI to confirm the correct position of the lead. Results: In 14 patients, leads were in suboptimal position after intraoperative CT scan positioning. The cases with alteration in the Z-axis were corrected immediately under fluoroscopic guidance. In all the 14 patients, an immediate repositioning was done. Conclusions: Based on our data, intraoperative CT scan is fast, safe, and a useful tool in the evaluation of the position of the implanted lead. It also reduces the patient's discomfort derived from the transfer of the patient from the operating room to the radiological department. However, intraoperative CT should not be considered as a substitute for postoperative MRI. PMID:27583182
Assessment of gunshot bullet injuries with the use of magnetic resonance imaging.
Hess, U; Harms, J; Schneider, A; Schleef, M; Ganter, C; Hannig, C
2000-10-01
Magnetic resonance imaging (MRI) is rarely used for preoperative assessment of shotgun injuries because of concerns of displacing the possibly ferromagnetic foreign body within the surrounding tissue. A total of 56 different projectiles underwent MRI testing for ferromagnetism and imaging quality in vitro and in pig carcasses with a commercially available 1.5-MRI scan. Image quality was compared with that of computed tomographic scans. Projectiles with ferromagnetic properties can be distinguished easily from nonferromagnetic ones by pretesting the motion of an identical projectile within the MRI coil. When ferromagnetic projectiles were excluded, MRI yielded the more precise images compared with other imaging techniques. Projectile localization and associated soft tissue injuries were visualized without artifacts in all cases. When ferromagnetic foreign bodies are excluded by pretesting their properties within the MRI with a comparative projectile, MRI portends an excellent imaging procedure for assessing the extent of injury and planning the removal by surgery.
Klatt, K; Schmidt, E; Scheuerle, A F
2008-04-01
The Ocular Hypertension Treatment Study (OHTS) has shown that analyzing changes of the optic disc configuration is superior to evaluating visual field findings for the early detection of primary open angle glaucoma. The Confocal Scanning Laser Ophthalmoscopy Ancillary Study (CSLO) is the first study to reveal that certain topographic baseline measurements of the optic disc are significantly associated with the development of primary open angle glaucoma in patients with ocular hypertension. An abnormally increased "mean height contour" value proved to be the individual parameter connected with the highest risk. The reliability of the Moorfields Regression Analysis of certain individual sectors during early detection of a primary angle glaucoma is higher than that of the global measurement. The temporal superior and inferior as well as the nasal inferior sectors have the highest positive predictive values and the largest risks in both univariate and multivariate analysis.
Meng, Yifei; Zuo, Jian -Min
2016-07-04
A diffraction-based technique is developed for the determination of three-dimensional nanostructures. The technique employs high-resolution and low-dose scanning electron nanodiffraction (SEND) to acquire three-dimensional diffraction patterns, with the help of a special sample holder for large-angle rotation. Grains are identified in three-dimensional space based on crystal orientation and on reconstructed dark-field images from the recorded diffraction patterns. Application to a nanocrystalline TiN thin film shows that the three-dimensional morphology of columnar TiN grains of tens of nanometres in diameter can be reconstructed using an algebraic iterative algorithm under specified prior conditions, together with their crystallographic orientations. The principles can bemore » extended to multiphase nanocrystalline materials as well. Furthermore, the tomographic SEND technique provides an effective and adaptive way of determining three-dimensional nanostructures.« less
Imaging and review of a large pre-auricular pilomatrixoma in a child.
Whittemore, Kenneth R; Cohen, Michael
2012-05-28
A 10-year-old girl presented with a mildly tender mass in the right preauricular region. The mass became larger, and the overlying skin turned purple. There was no clinical response to a course of either cephalexin or clarithromycin. The remainder of the head and neck examination was normal including normal facial nerve function. Lyme titers and a computed tomographic (CT) scan with contrast of the facial region were obtained. The CT scan demonstrated the lesion to be superficial to the parotid gland. The lyme titer was elevated and doxycycline was begun. The mass appeared to reduce in size after doxycycline treatment, but then grew and turned erythematous. The lesion was surgically excised and was vascular with calcification and cheesy inclusions. The mass was quite close to the skin and the clinical diagnosis at the time of surgery was a pilomatrixoma, which was corroborated on pathological evaluation.
2012-01-01
The present study is a report of retrospective case series of stress fracture of the olecranon. Six patients presented posterior elbow pain in throwing in baseball and softball, but fracture was not diagnosed in radiographs. We detected stress fracture of the olecranon using computed tomographic (CT) scan and treated the patient with internal fixation with a headless cannulated double threaded screw through a small skin incision. All patients returned to competitive level without elbow complaints after the operation. When throwing athletes present with unusual posterior elbow pain and no significant findings on radiographs, a CT scan examination should be performed. We recommend surgical treatment of internal fixation with a screw through a small skin incision, as a good option for stress fracture of the olecranon in order to allow early return to sports activity in competitive athletes. PMID:23241173
Cauley, K A; Hu, Y; Och, J; Yorks, P J; Fielden, S W
2018-04-01
The majority of brain growth and development occur in the first 2 years of life. This study investigated these changes by analysis of the brain radiodensity histogram of head CT scans from the clinical population, 0-2 years of age. One hundred twenty consecutive head CTs with normal findings meeting the inclusion criteria from children from birth to 2 years were retrospectively identified from 3 different CT scan platforms. Histogram analysis was performed on brain-extracted images, and histogram mean, mode, full width at half maximum, skewness, kurtosis, and SD were correlated with subject age. The effects of scan platform were investigated. Normative curves were fitted by polynomial regression analysis. Average total brain volume was 360 cm 3 at birth, 948 cm 3 at 1 year, and 1072 cm 3 at 2 years. Total brain tissue density showed an 11% increase in mean density at 1 year and 19% at 2 years. Brain radiodensity histogram skewness was positive at birth, declining logarithmically in the first 200 days of life. The histogram kurtosis also decreased in the first 200 days to approach a normal distribution. Direct segmentation of CT images showed that changes in brain radiodensity histogram skewness correlated with, and can be explained by, a relative increase in gray matter volume and an increase in gray and white matter tissue density that occurs during this period of brain maturation. Normative metrics of the brain radiodensity histogram derived from routine clinical head CT images can be used to develop a model of normal brain development. © 2018 by American Journal of Neuroradiology.
Missouri University Multi-Plane Imager (MUMPI): A high sensitivity rapid dynamic ECT brain imager
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, K.W.; Holmes, R.A.
1984-01-01
The authors have designed a unique ECT imaging device that can record rapid dynamic images of brain perfusion. The Missouri University Multi-Plane Imager (MUMPI) uses a single crystal detector that produces four orthogonal two-dimensional images simultaneously. Multiple slice images are reconstructed from counts recorded from stepwise or continuous collimator rotation. Four simultaneous 2-d image fields may also be recorded and reviewed. The cylindrical sodium iodide crystal and the rotating collimator concentrically surround the source volume being imaged with the collimator the only moving part. The design and function parameters of MUMPI have been compared to other competitive tomographic head imagingmore » devices. MUMPI's principal advantages are: 1) simultaneous direct acquisition of four two-dimensional images; 2) extremely rapid project set acquisition for ECT reconstruction; and 3) instrument practicality and economy due to single detector design and the absence of heavy mechanical moving components (only collimator rotation is required). MUMPI should be ideal for imaging neutral lipophilic chelates such as Tc-99m-PnAO which passively diffuses across the intact blood-brain-barrier and rapidly clears from brain tissue.« less
Near-Infrared Spectroscopy: A Promising Prehospital Tool for Management of Traumatic Brain Injury.
Peters, Joost; Van Wageningen, Bas; Hoogerwerf, Nico; Tan, Edward
2017-08-01
Introduction Early identification of traumatic brain injury (TBI) is essential. Near-infrared spectroscopy (NIRS) can be used in prehospital settings for non-invasive monitoring and the diagnosis of patients who may require surgical intervention. The handheld NIRS Infrascanner (InfraScan Inc.; Philadelphia, Pennsylvania USA) uses eight symmetrical scan points to detect intracranial bleeding. A scanner was tested in a physician-staffed helicopter Emergency Medical Service (HEMS). The results were compared with those obtained using in-hospital computed tomography (CT) scans. Scan time, ease-of-use, and change in treatment were scored. A total of 25 patients were included. Complete scans were performed in 60% of patients. In 15 patients, the scan was abnormal, and in one patient, the scan resulted in a treatment change. Compared with the results of CT scanning, the Infrascanner obtained a sensitivity of 93.3% and a specificity of 78.6%. Most patients had severe TBI with indication for transport to a trauma center prior to scanning. In one patient, the scan resulted in a treatment change. Evaluation of patients with less severe TBI is needed to support the usefulness of the Infrascanner as a prehospital triage tool. Promising results were obtained using the InfraScan NIRS device in prehospital screening for intracranial hematomas in TBI patients. High sensitivity and good specificity were found. Further research is necessary to determine the beneficial effects of enhanced prehospital screening on triage, survival, and quality of life in TBI patients. Peters J , Van Wageningen B , Hoogerwerf N , Tan E . Near-infrared spectroscopy: a promising prehospital tool for management of traumatic brain injury. Prehosp Disaster Med. 2017;32(4):414-418.
Automated extraction of subdural electrode grid from post-implant MRI scans for epilepsy surgery
NASA Astrophysics Data System (ADS)
Pozdin, Maksym A.; Skrinjar, Oskar
2005-04-01
This paper presents an automated algorithm for extraction of Subdural Electrode Grid (SEG) from post-implant MRI scans for epilepsy surgery. Post-implant MRI scans are corrupted by the image artifacts caused by implanted electrodes. The artifacts appear as dark spherical voids and given that the cerebrospinal fluid is also dark in T1-weigthed MRI scans, it is a difficult and time-consuming task to manually locate SEG position relative to brain structures of interest. The proposed algorithm reliably and accurately extracts SEG from post-implant MRI scan, i.e. finds its shape and position relative to brain structures of interest. The algorithm was validated against manually determined electrode locations, and the average error was 1.6mm for the three tested subjects.
Transverse section radionuclide scanning system
Kuhl, David E.; Edwards, Roy Q.
1976-01-01
This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three-dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program.
Han, Kihwan; Mac Donald, Christine L.; Johnson, Ann M.; Barnes, Yolanda; Wierzechowski, Linda; Zonies, David; Oh, John; Flaherty, Stephen; Fang, Raymond; Raichle, Marcus E.; Brody, David L.
2013-01-01
Blast-related traumatic brain injury (TBI) has been one of the “signature injuries” of the wars in Iraq and Afghanistan. However, neuroimaging studies in concussive ‘mild’ blast-related TBI have been challenging due to the absence of abnormalities in computed tomography or conventional magnetic resonance imaging (MRI) and the heterogeneity of the blast-related injury mechanisms. The goal of this study was to address these challenges utilizing single-subject, module-based graph theoretic analysis of resting-state functional MRI (fMRI) data. We acquired 20 minutes of resting-state fMRI in 63 U.S. military personnel clinically diagnosed with concussive blast-related TBI and 21 U.S. military controls who had blast exposures but no diagnosis of TBI. All subjects underwent an initial scan within 90 days post-injury and 65 subjects underwent a follow-up scan 6 to 12 months later. A second independent cohort of 40 U.S. military personnel with concussive blast-related TBI patients served as a validation dataset. The second independent cohort underwent an initial scan within 30 days post-injury. 75% of scans were of good quality, with exclusions primarily due to excessive subject motion. Network analysis of the subset of these subjects in the first cohort with good quality scans revealed spatially localized reductions in participation coefficient, a measure of between-module connectivity, in the TBI patients relative to the controls at the time of the initial scan. These group differences were less prominent on the follow-up scans. The 15 brain areas with the most prominent reductions in participation coefficient were next used as regions of interest (ROIs) for single-subject analyses. In the first TBI cohort, more subjects than would be expected by chance (27/47 versus 2/47 expected, p < 0.0001) had 3 or more brain regions with abnormally low between-module connectivity relative to the controls on the initial scans. On the follow-up scans, more subjects than expected by chance (5/37, p = 0.044) but fewer subjects than on the initial scans had 3 or more brain regions with abnormally low between-module connectivity. Analysis of the second TBI cohort validation dataset with no free parameters provided a partial replication; again more subjects than expected by chance (8/31, p = 0.006) had 3 or more brain regions with abnormally low between-module connectivity on the initial scans, but the numbers were not significant (2/27, p = 0.276) on the follow-up scans. A single-subject, multivariate analysis by probabilistic principal component analysis of the between-module connectivity in the 15 identified ROIs, showed that 31/47 subjects in the first TBI cohort were found to be abnormal relative to the controls on the initial scans. In the second TBI cohort, 9/31 patients were found to be abnormal in identical multivariate analysis with no free parameters. Again, there were not substantial differences on the follow-up scans. Taken together, these results indicate that single-subject, module-based graph theoretic analysis of resting-state fMRI provides potentially useful information for concussive blast-related TBI if high quality scans can be obtained. The underlying biological mechanisms and consequences of disrupted between-module connectivity are unknown, thus further studies are required. PMID:23968735
van Rossum, A. B.; Treurniet, F. E.; Kieft, G. J.; Smith, S. J.; Schepers-Bok, R.
1996-01-01
BACKGROUND: A study was carried out to evaluate the potential place of spiral volumetric computed tomography (SVCT) in the diagnostic strategy for pulmonary embolism. METHODS: In a prospective study 249 patients with clinical suspicion of pulmonary embolism were evaluated with various imaging techniques. In all patients a ventilation/perfusion (V/Q) scan was performed. Seventy seven patients with an abnormal V/Q scan underwent SVCT. Pulmonary angiography was then performed in all 42 patients with a non-diagnostic V/Q scan and in three patients with a high probability V/Q scan without emboli on the SVCT scan. Patients with an abnormal perfusion scan also underwent ultrasonography of the legs for the detection of deep vein thrombosis. RESULTS: One hundred and seventy two patients (69%) had a normal V/Q scan. Forty two patients (17%) had a non-diagnostic V/Q scan, and in five of these patients pulmonary emboli were found both by SVCT and pulmonary angiography. In one patient, although SVCT showed no emboli, the angiogram was positive for pulmonary embolism. In one of the 42 patients the SVCT scan showed an embolus which was not confirmed by pulmonary angiography. The other 35 patients showed no sign of emboli. Thirty five patients (14%) had a high probability V/Q scan, and in 32 patients emboli were seen on SVCT images. Two patients had both a negative SVCT scan and a negative pulmonary angiogram. In one who had an inconclusive SVCT scan pulmonary angiography was positive. The sensitivity for pulmonary embolism was 95% and the specificity 97%; the positive and negative predicted values of SVCT were 97% and 97%, respectively. CONCLUSIONS: SVCT is a relatively noninvasive test for pulmonary embolism which is both sensitive and specific and which may serve as an alternative to ventilation scintigraphy and possibly to pulmonary angiography in the diagnostic strategy for pulmonary embolism. Images PMID:8658363
Sekine, Tetsuro; Amano, Yasuo; Takagi, Ryo; Matsumura, Yoshio; Murai, Yasuo; Kumita, Shinichiro
2014-01-01
A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. Sixteen volunteers underwent 3 types of 4D Flow MR imaging of the brain using a 3.0-tesla scanner. As the standard scan, 4D Flow MR imaging with SENSE was performed first and then followed by 2 types of acceleration scan-with Cartesian y-z radial sampling and with k-t SENSE. We measured peak systolic velocity (PSV) and blood flow volume (BFV) in 9 arteries, and the percentage of particles arriving from the emitter plane at the target plane in 3 arteries, visually graded image quality in 9 arteries, and compared these quantitative and visual data between the standard scan and each acceleration scan. 4D Flow MR imaging examinations were completed in all but one volunteer, who did not undergo the last examination because of headache. Each acceleration scan reduced scan time by 50% compared with the standard scan. The k-t SENSE imaging underestimated PSV and BFV (P < 0.05). There were significant correlations for PSV and BFV between the standard scan and each acceleration scan (P < 0.01). The percentage of particles reaching the target plane did not differ between the standard scan and each acceleration scan. For visual assessment, y-z radial sampling deteriorated the image quality of the 3 arteries. Cartesian y-z radial sampling is feasible for measuring flow, and k-t SENSE offers sufficient flow visualization; both allow acquisition of 4D Flow MR imaging with shorter scan time.
Schiff, D; Rosenblum, M K
1998-03-01
Although herpes simplex encephalitis (HSE) is not regarded as an opportunistic infection, the occurrence of HSE in immunocompromised patients has been documented and the suggestion made that unusual clinical and neuropathologic features characterize the disorder in this population. To further characterize HSE as it affects the immunodeficient, the authors reviewed the clinical and pathological findings in three immunocompromised patients with autopsy-proven HSE. Two patients had cancer (one with lymphoma and another with glioblastoma multiforme), one was known to be human immunodeficiency virus-type 1 (HIV-1)-seropositive and a second was suspected of harboring underlying HIV-1 infection. Two were receiving dexamethasone at onset of HSE. All had fever, mental status changes and new, focal neurological deficits or worsening of established deficits. Cerebrospinal fluid (CSF) pleocytosis was absent or minimal and head computerized tomographic (CT) scans, performed in all cases, were unrevealing. No patient was clinically suspected of having HSE, only one received acyclovir (for concurrent mucocutaneous herpes) and HSE played a major role in all deaths. Autopsy revealed an unusual form of HSE characterized by a noninflammatory, pseudoischemic histological presentation and the unexpected persistence of viral antigens in abundance despite survival beyond the clinical stage during which inflammatory responses usually peak and productive brain infection wanes. The incidence of HSE in the immunocompromised may be underestimated. Preexistent neurological disease, a noninflammatory CSF profile and negative CT scan may confound the diagnosis in this population, a typical clinical presentation notwithstanding. Increased clinical suspicion, the use of magnetic resonance imaging and polymerase chain reaction analysis of CSF for herpes simplex virus nucleic acid sequences may permit more rapid diagnosis and treatment. The absence of inflammatory infiltrates in some fatal cases of HSE suggests that an intact immune response is not requisite to the devastating neurological injury characteristic of this disorder.
Advanced imaging in acute stroke management-Part I: Computed tomographic.
Saini, Monica; Butcher, Ken
2009-01-01
Neuroimaging is fundamental to stroke diagnosis and management. Non-contrast computed tomography (NCCT) has been the primary imaging modality utilized for this purpose for almost four decades. Although NCCT does permit identification of intracranial hemorrhage and parenchymal ischemic changes, insights into blood vessel patency and cerebral perfusion are limited. Advances in reperfusion strategies have made identification of potentially salvageable brain tissue a more practical concern. Advances in CT technology now permit identification of acute and chronic arterial lesions, as well as cerebral blood flow deficits. This review outlines principles of advanced CT image acquisition and its utility in acute stroke management.
Navigation-supported diagnosis of the substantia nigra by matching midbrain sonography and MRI
NASA Astrophysics Data System (ADS)
Salah, Zein; Weise, David; Preim, Bernhard; Classen, Joseph; Rose, Georg
2012-03-01
Transcranial sonography (TCS) is a well-established neuroimaging technique that allows for visualizing several brainstem structures, including the substantia nigra, and helps for the diagnosis and differential diagnosis of various movement disorders, especially in Parkinsonian syndromes. However, proximate brainstem anatomy can hardly be recognized due to the limited image quality of B-scans. In this paper, a visualization system for the diagnosis of the substantia nigra is presented, which utilizes neuronavigated TCS to reconstruct tomographical slices from registered MRI datasets and visualizes them simultaneously with corresponding TCS planes in realtime. To generate MRI tomographical slices, the tracking data of the calibrated ultrasound probe are passed to an optimized slicing algorithm, which computes cross sections at arbitrary positions and orientations from the registered MRI dataset. The extracted MRI cross sections are finally fused with the region of interest from the ultrasound image. The system allows for the computation and visualization of slices at a near real-time rate. Primary tests of the system show an added value to the pure sonographic imaging. The system also allows for reconstructing volumetric (3D) ultrasonic data of the region of interest, and thus contributes to enhancing the diagnostic yield of midbrain sonography.
Full-angle tomographic phase microscopy of flowing quasi-spherical cells.
Villone, Massimiliano M; Memmolo, Pasquale; Merola, Francesco; Mugnano, Martina; Miccio, Lisa; Maffettone, Pier Luca; Ferraro, Pietro
2017-12-19
We report a reliable full-angle tomographic phase microscopy (FA-TPM) method for flowing quasi-spherical cells along microfluidic channels. This method lies in a completely passive optical system, i.e. mechanical scanning or multi-direction probing of the sample is avoided. It exploits the engineered rolling of cells while they are flowing along a microfluidic channel. Here we demonstrate significant progress with respect to the state of the art of in-flow TPM by showing a general extension to cells having almost spherical shapes while they are flowing in suspension. In fact, the adopted strategy allows the accurate retrieval of rotation angles through a theoretical model of the cells' rotation in a dynamic microfluidic flow by matching it with phase-contrast images resulting from holographic reconstructions. So far, the proposed method is the first and the only one that permits to get in-flow TPM by probing the cells with full-angle, achieving accurate 3D refractive index mapping and the simplest optical setup, simultaneously. Proof of concept experiments were performed successfully on human breast adenocarcinoma MCF-7 cells, opening the way for the full characterization of circulating tumor cells (CTCs) in the new paradigm of liquid biopsy.
Park, Eun-Ah; Lee, Whal; Chung, Se-Young; Yin, Yong Hu; Chung, Jin Wook; Park, Jae Hyung
2010-01-01
To determine the optimal scan timing and adequate intravenous route for patients having undergone the Fontan operation. A total of 88 computed tomographic images in 49 consecutive patients who underwent the Fontan operation were retrospectively evaluated and divided into 7 groups: group 1, bolus-tracking method with either intravenous route (n = 20); group 2, 1-minute-delay scan with single antecubital route (n = 36); group 3, 1-minute-delay scan with both antecubital routes (n = 2); group 4, 1-minute-delay scan with foot vein route (n = 3); group 5, 1-minute-delay scan with simultaneous infusion via both antecubital and foot vein routes (n = 2); group 6, 3-minute-delay scan with single antecubital route (n = 22); and group 7, 3-minute-delay scan with foot vein route (n = 3). The presence of beam-hardening artifact, uniform enhancement, and optimal enhancement was evaluated at the right pulmonary artery (RPA), left pulmonary artery (LPA), and Fontan tract. Optimal enhancement was determined when evaluation of thrombus was possible. Standard deviation was measured at the RPA, LPA, and Fontan tract. Beam-hardening artifacts of the RPA, LPA, and Fontan tract were frequently present in groups 1, 4, and 5. The success rate of uniform and optimal enhancement was highest (100%) in groups 6 and 7, followed by group 2 (75%). An SD of less than 30 Hounsfield unit for the pulmonary artery and Fontan tract was found in groups 3, 6, and 7. The optimal enhancement of the pulmonary arteries and Fontan tract can be achieved by a 3-minute-delay scan irrespective of the intravenous route location.
Introduction of a pan-scan protocol for blunt trauma activations: what are the consequences?
James, Melissa K; Schubl, Sebastian D; Francois, Michael P; Doughlin, Geoffrey K; Lee, Shi-Wen
2017-01-01
The aim of this study is to determine if the introduction of a pan-scan protocol during the initial assessment for blunt trauma activations would affect missed injuries, incidental findings, treatment times, radiation exposure, and cost. A 6-month prospective study was performed on patients with blunt trauma at a level 1 trauma center. During the last 3 months of the study, a pan-scan protocol was introduced to the trauma assessment. Categorical data were analyzed by Fisher exact test and continuous data were analyzed by Mann-Whitney nonparametric test. There were a total of 220 patients in the pre-pan-scan period and 206 patients during the pan-scan period. There was no significant difference in injury severity or mortality between the groups. Introduction of the pan-scan protocol substantially reduced the incidence of missed injuries from 3.2% to 0.5%, the length of stay in the emergency department by 68.2 minutes (95% confidence interval [CI], -134.4 to -2.1), and the mean time to the first operating room visit by 1465 minutes (95% CI, -2519 to -411). In contrast, fixed computed tomographic scan cost increased by $48.1 (95% CI, 32-64.1) per patient; however, total radiology cost per patient decreased by $50 (95% CI, -271.1 to 171.4). In addition, the rate of incidental findings increased by 14.4% and the average radiation exposure per patient was 8.2 mSv (95% CI, 5.0-11.3) greater during the pan-scan period. Although there are advantages to whole-body computed tomography, elucidation of the appropriate blunt trauma patient population is warranted when implementing a pan-scan protocol. Copyright © 2016 Elsevier Inc. All rights reserved.
High-resolution whole-brain diffusion MRI at 7T using radiofrequency parallel transmission.
Wu, Xiaoping; Auerbach, Edward J; Vu, An T; Moeller, Steen; Lenglet, Christophe; Schmitter, Sebastian; Van de Moortele, Pierre-François; Yacoub, Essa; Uğurbil, Kâmil
2018-03-30
Investigating the utility of RF parallel transmission (pTx) for Human Connectome Project (HCP)-style whole-brain diffusion MRI (dMRI) data at 7 Tesla (7T). Healthy subjects were scanned in pTx and single-transmit (1Tx) modes. Multiband (MB), single-spoke pTx pulses were designed to image sagittal slices. HCP-style dMRI data (i.e., 1.05-mm resolutions, MB2, b-values = 1000/2000 s/mm 2 , 286 images and 40-min scan) and data with higher accelerations (MB3 and MB4) were acquired with pTx. pTx significantly improved flip-angle detected signal uniformity across the brain, yielding ∼19% increase in temporal SNR (tSNR) averaged over the brain relative to 1Tx. This allowed significantly enhanced estimation of multiple fiber orientations (with ∼21% decrease in dispersion) in HCP-style 7T dMRI datasets. Additionally, pTx pulses achieved substantially lower power deposition, permitting higher accelerations, enabling collection of the same data in 2/3 and 1/2 the scan time or of more data in the same scan time. pTx provides a solution to two major limitations for slice-accelerated high-resolution whole-brain dMRI at 7T; it improves flip-angle uniformity, and enables higher slice acceleration relative to current state-of-the-art. As such, pTx provides significant advantages for rapid acquisition of high-quality, high-resolution truly whole-brain dMRI data. © 2018 International Society for Magnetic Resonance in Medicine.
Radioisotope scanning of brain, liver, lung and bone with a note on tumour localizing agents
Lavender, J. P.
1973-01-01
Radioisotopic scanning of brain, liver, lungs and the skeleton is briefly reviewed with a survey of recent developments of clinical significance. In brain scanning neoplasm detection rates of greater than 90% are claimed. The true figure is probably 70-80%. Autopsy data shows a number of false negatives, particularly with vascular lesions. Attempts to make scanning more specific in differentiating neoplasm from vascular lesions by rapid sequence blood flow studies are reviewed. In liver scanning by means of colloids again high success rate is claimed but small metastases are frequently missed and the false negative scan rate is probably quite high. Lung scanning still has its main place in investigating pulmonary embolic disease. Ventilation studies using Xenon 133 are useful, particularly combined with perfusion studies. The various radiopharmaceuticals for use in bone scanning are reviewed. The appearance of technetium labelled phosphate compounds will probably allow much wider use of total skeletal scanning. Research into tumour localizing agents continues, the most recent and interesting being Gallium citrate and labelled bleomycin. Neither agent is predictable however although Gallium may have a place in Hodgkins disease and bronchogenic neoplasm and both may have a place in the detection of cerebral tumours. ImagesFig. 1Fig. 2Fig. 3p452-bFig. 3bFig. 4Fig. 5Fig. 5bFig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 12c & 12dFig. 13Fig. 13 b,c,dFig. 14Fig. 14bFig. 15Fig. 15bFig. 16Fig. 17Fig. 18 PMID:4602127
Rationale for Activity Based Alternatives in Lieu of Lectures. Research Brief
ERIC Educational Resources Information Center
Walker, Karen
2005-01-01
Since the 1990s was declared to be the decade of the brain, technology has advanced enough through MRIs, CAT Scans and PET Scans, that live brains have been able to be studied. Although this is still a relatively new field of study, what has been discovered thus far, has wide reaching implications for educators in the area of pedagogy and how to…
Geng, Shujie; Liu, Xiangyu; Biswal, Bharat B; Niu, Haijing
2017-01-01
As an emerging brain imaging technique, functional near infrared spectroscopy (fNIRS) has attracted widespread attention for advancing resting-state functional connectivity (FC) and graph theoretical analyses of brain networks. However, it remains largely unknown how the duration of the fNIRS signal scanning is related to stable and reproducible functional brain network features. To answer this question, we collected resting-state fNIRS signals (10-min duration, two runs) from 18 participants and then truncated the hemodynamic time series into 30-s time bins that ranged from 1 to 10 min. Measures of nodal efficiency, nodal betweenness, network local efficiency, global efficiency, and clustering coefficient were computed for each subject at each fNIRS signal acquisition duration. Analyses of the stability and between-run reproducibility were performed to identify optimal time length for each measure. We found that the FC, nodal efficiency and nodal betweenness stabilized and were reproducible after 1 min of fNIRS signal acquisition, whereas network clustering coefficient, local and global efficiencies stabilized after 1 min and were reproducible after 5 min of fNIRS signal acquisition for only local and global efficiencies. These quantitative results provide direct evidence regarding the choice of the resting-state fNIRS scanning duration for functional brain connectivity and topological metric stability of brain network connectivity.
Naeser, M A; Baker, E H; Palumbo, C L; Nicholas, M; Alexander, M P; Samaraweera, R; Prete, M N; Hodge, S M; Weissman, T
1998-11-01
To test whether lesion site patterns in patients with chronic, severe aphasia who have no meaningful spontaneous speech are predictive of outcome following treatment with a nonverbal, icon-based computer-assisted visual communication (C-ViC) program. Retrospective study in which computed tomographic scans performed 3 months after onset of stroke and aphasia test scores obtained before C-ViC therapy were reviewed for patients after receiving C-ViC treatment. A neurology department and speech pathology service of a Department of Veterans Affairs medical center and a university aphasia research center. Seventeen patients with stroke and severe aphasia who began treatment with C-ViC from 3 months to 10 years after onset of stroke. Level of ability to use C-ViC on a personal computer to communicate. All patients with bilateral lesions failed to learn C-ViC. For patients with unilateral left hemisphere lesion sites, statistical analyses accurately discriminated between those who could initiate communication with C-ViC from those who were only able to answer directed questions. The critical lesion areas involved temporal lobe structures (Wernicke cortical area and the subcortical temporal isthmus), supraventricular frontal lobe structures (supplementary motor area or cingulate gyrus 24), and the subcortical medial subcallosal fasciculus, deep to the Broca area. Specific lesion sites were also identified for appropriate candidacy for C-ViC. Lesion site patterns on computed tomographic scans are helpful to define candidacy for C-ViC training, and to predict outcome level. A practical method is presented for clinical application of these lesion site results in combination with aphasia test scores.
Cumulative radiation dose caused by radiologic studies in critically ill trauma patients.
Kim, Patrick K; Gracias, Vicente H; Maidment, Andrew D A; O'Shea, Michael; Reilly, Patrick M; Schwab, C William
2004-09-01
Critically ill trauma patients undergo many radiologic studies, but the cumulative radiation dose is unknown. The purpose of this study was to estimate the cumulative effective dose (CED) of radiation resulting from radiologic studies in critically ill trauma patients. The study group was composed of trauma patients at an urban Level I trauma center with surgical intensive care unit length of stay (LOS) greater than 30 days. The radiology records were reviewed. A typical effective dose per study for each type of plain film radiograph, computed tomographic scan, fluoroscopic study, and nuclear medicine study was used to calculate CED. Forty-six patients met criteria. The mean surgical intensive care unit and hospital LOS were 42.7 +/- 14.0 and 59.5 +/- 28.5 days, respectively. The mean Injury Severity Score was 32.2 +/- 15.0. The mean number of studies per patient was 70.1 +/- 29.0 plain film radiographs, 7.8 +/- 4.1 computed tomographic scans, 2.5 +/- 2.6 fluoroscopic studies, and 0.065 +/- 0.33 nuclear medicine study. The mean CED was 106 +/- 59 mSv per patient (range, 11-289 mSv; median, 104 mSv). Among age, mechanism, Injury Severity Score, and LOS, there was no statistically significant predictor of high CED. The mean CED in the study group was 30 times higher than the average yearly radiation dose from all sources for individuals in the United States. The theoretical additional morbidity attributable to radiologic studies was 0.78%. From a radiobiologic perspective, risk-to-benefit ratios of radiologic studies are favorable, given the importance of medical information obtained. Current practice patterns regarding use of radiologic studies appear to be acceptable.
Relationship Between Visceral Infarction and Ischemic Stroke Subtype.
Finn, Caitlin; Hung, Peter; Patel, Praneil; Gupta, Ajay; Kamel, Hooman
2018-03-01
Most cryptogenic strokes are thought to have an embolic source. We sought to determine whether cryptogenic strokes are associated with visceral infarcts, which are usually embolic. Among patients prospectively enrolled in CAESAR (Cornell Acute Stroke Academic Registry), we selected those with a contrast-enhanced abdominal computed tomographic scan within 1 year of admission. Our exposure variable was adjudicated stroke subtype per the Trial of ORG 10172 in Acute Stroke Treatment classification. Our outcome was renal or splenic infarction as assessed by a single radiologist blinded to stroke subtype. We used Fisher exact test and multiple logistic regression to compare the prevalence of visceral infarcts among cardioembolic strokes, strokes of undetermined etiology, and noncardioembolic strokes (large- or small-vessel strokes). Among 227 patients with ischemic stroke and a contrast-enhanced abdominal computed tomographic scan, 59 had a visceral infarct (35 renal and 27 splenic). The prevalence of visceral infarction was significantly different among cardioembolic strokes (34.2%; 95% confidence interval [CI], 23.7%-44.6%), strokes of undetermined etiology (23.9%; 95% CI, 15.0%-32.8%), and strokes from large-artery atherosclerosis or small-vessel occlusion (12.5%; 95% CI, 1.8%-23.2%; P =0.03). In multiple logistic regression models adjusted for demographics and vascular comorbidities, we found significant associations with visceral infarction for both cardioembolic stroke (odds ratio, 3.5; 95% CI, 1.2-9.9) and stroke of undetermined source (odds ratio, 3.3; 95% CI, 1.1-10.5) as compared with noncardioembolic stroke. The prevalence of visceral infarction differed significantly across ischemic stroke subtypes. Cardioembolic and cryptogenic strokes were associated with a higher prevalence of visceral infarcts than noncardioembolic strokes. © 2018 American Heart Association, Inc.
Jastrzębski, Jan; Kępka, Cezary; Kruk, Mariusz; Demkow, Marcin; Kalińczuk, Łukasz; Wolny, Rafał; Ciszewski, Michał; Michałowska, Ilona; Witkowski, Adam
2013-01-01
Introduction Heart rate irregularities are the major limitations of computed tomographic coronary angiography (CTCA) due to severe motion artifacts. Aim To evaluate the safety and efficacy of a lidocaine intravenous bolus in preserving good image quality by the transient suppression of premature ventricular contractions (PVC) during the CTCA scan. Material and methods The study group comprised 67 consecutive patients with sinus rhythm and numerous PVC scheduled for CTCA. Intravenous boluses of 25–50 mg lidocaine were given after calcium score assessment and immediately before CTCA. The control group comprised 67 patients with sinus rhythm without PVC matched according to the body mass index (BMI), age, sex, and calcium score. All coronary vessel segments were assessed for image quality and presence of significant stenosis. Results As compared with calcium score assessment, after administration of lidocaine and during the CTCA scan PVC were completely suppressed in 22 (40%), reduced in 10 (18%), unchanged in 18 (32%), and intensified in 5 (10%) patients. Overall, there were 32 (58%) patients with sinus rhythm during CTCA as compared with only 11 (20%) patients free from PVC during calcium score assessment (p < 0.001). Image quality in 871 coronary segments including both the study group and control patients was worse in patients with PVC (p < 0.0001). However, there was no statistically significant difference in the number of patients with at least one segment of non-diagnostic quality (6% vs. 12%, p = 0.36; respectively). Conclusions Single lidocaine bolus given prior to CTCA is safe, may temporarily eliminate or reduce the intensity of arrhythmia, and hence results in improved quality of CTCA in patients with numerous PVC. PMID:24570719
Poorey, V K; Gupta, Neha
2014-09-01
To correlate symptoms of deviated nasal septum (DNS) and chronic rhinosinusitis with the findings of nasal endoscopy and computed tomographic (CT) imaging. To evaluate the influence of degree of septal angle deviation on the severity of lateral nasal wall abnormalities. A prospective study was conducted on 67 patients with clinical evidence of DNS and chronic sinusitis attending ENT OPD between January 2012 and September 2013. All these patients underwent nasal endoscopy and CT scan PNS coronal sections. Direction and degree of DNS was recorded. Range of sinus mucosal thickening on CT scan films was also recorded. Chronic sinusitis is common in the age group between 21 and 40 years (50.74 %) with male preponderance (55.22 %), chief symptoms being nasal obstruction (86.56 %), headache (73.13 %) and nasal discharge (52.23 %). Left sided DNS is more common (64.17 %). Most of the patients have moderate DNS, i.e. 6°-10° (56.7 %), followed by severe (22.4 %) and then mild (20.9 %). DNS results in compensatory structural changes in the turbinates and/or lateral nasal wall which causes ostiomeatal complex (OMC) obstruction resulting in sinusitis. Contralateral concha bullosa and ethmoid bulla prominence was noted. Maxillary sinus is most commonly affected sinus (73.13 %). Patients with increasing septal angles were associated with a higher incidence of maxillary sinus mucosal changes (p < 0.05). Present study reemphasized the concept that septal deviation causes obstruction at OMC which results in an increased incidence and severity of bilateral chronic sinus disease.
Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo
2014-08-01
This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P < .05). In the scanning electron microscopic analysis, file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Understanding External Cervical Resorption in Vital Teeth.
Mavridou, Athina M; Hauben, Esther; Wevers, Martine; Schepers, Evert; Bergmans, Lars; Lambrechts, Paul
2016-12-01
The aim of this study was to investigate the 3-dimensional (3D) structure and the cellular and tissue characteristics of external cervical resorption (ECR) in vital teeth and to understand the phenomenon of ECR by combining histomorphological and radiographic findings. Twenty-seven cases of vital permanent teeth displaying ECR were investigated. ECR diagnosis was based on clinical and radiographic examination with cone-beam computed tomographic imaging. The extracted teeth were further analyzed by using nanofocus computed tomographic imaging, hard tissue histology, and scanning electron microscopy. All examined teeth showed some common characteristics. Based on the clinical and experimental findings, a 3-stage mechanism of ECR was proposed. At the first stage (ie, the initiation stage), ECR was initiated at the cementum below the gingival epithelial attachment. At the second stage (ie, the resorption stage), the resorption invaded the tooth structure 3-dimensionally toward the pulp space. However, it did not penetrate the pulp space because of the presence of a pericanalar resorption-resistant sheet. This layer was observed to consist of predentin, dentin, and occasionally reparative mineralized (bonelike) tissue, having a fluctuating thickness averaging 210 μm. At the last advanced stage (ie, the repair stage), repair took place by an ingrowth and apposition of bonelike tissue into the resorption cavity. During the reparative stage, repair and remodeling phenomena evolve simultaneously, whereas both resorption and reparative stages progress in parallel at different areas of the tooth. ECR is a dynamic and complex condition that involves periodontal and endodontic tissues. Using clinical, histologic, radiographic, and scanning microscopic analysis, a better understanding of the evolution of ECR is possible. Based on the experimental findings, a 3-stage mechanism for the initiation and growth of ECR is proposed. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Fluence compensated photoacoustic tomography in small animals (Conference Presentation)
NASA Astrophysics Data System (ADS)
Hussain, Altaf; Pool, Martin; Daoudi, Khalid; de Vries, Liesbeth G.; Steenbergen, Wiendelt
2017-03-01
Light fluence inside turbid media can be experimentally mapped by measuring ultrasonically modulated light (Acousto-optics). To demonstrate the feasibility of fluence corrected Photoacoustic (PA) imaging, we have realized a tri-modality (i.e. photoacoustic, acousto-optic and ultrasound) tomographic small animal imaging system. Wherein PA imaging provides high resolution map of absorbed optical energy density, Acousto-optics yields the fluence distribution map in the corresponding PA imaging plane and Ultrasound provides morphological information. Further, normalization of the PA image with the acousto-optically measured fluence map results in an image that directly represents the optical absorption. Human epidermal growth factor receptor 2 (HER2) is commonly found overexpressed in human cancers, among which breast cancers, resulting in a more aggressive tumor phenotype. Identification of HER2-expression is clinically relevant, because cancers overexpressing this marker are amenable to HER2-directed therapies, among which antibodies trastuzumab and pertuzumab. Here, we investigate the feasibility and advantage of acousto-optically assisted fluence compensated PA imaging over PA imaging alone in visualizing and quantifying HER2 expression. For this experiment, nude mice were xenografted with human breast cancer cell lines SKBR3 and BT474 (both HER2 overexpressing), as well as HER2-negative MDA-MB-231. To visualize HER2 expression in these mice, HER2 monoclonal antibody pertuzumab (Perjeta®, Roche), was conjugated to near-infrared dye IRDye 800CW (800CW, LICOR Biosciences) at a ratio of 1∶2 antibody to 800CW. When xenograft tumors measured ≥ 100 mm3, mice received 100 µg 800CW-pertuzumab intravenously. Three days post injection, mice were scanned for fluorescence signal with an IVIS scanner. After fluorescence scans, mice were euthanized and imaged in our PA tomographic imaging system.
Development of the two Korean adult tomographic computational phantoms for organ dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Choonsik; Lee, Choonik; Park, Sang-Hyun
2006-02-15
Following the previously developed Korean tomographic phantom, KORMAN, two additional whole-body tomographic phantoms of Korean adult males were developed from magnetic resonance (MR) and computed tomography (CT) images, respectively. Two healthy male volunteers, whose body dimensions were fairly representative of the average Korean adult male, were recruited and scanned for phantom development. Contiguous whole body MR images were obtained from one subject exclusive of the arms, while whole-body CT images were acquired from the second individual. A total of 29 organs and tissues and 19 skeletal sites were segmented via image manipulation techniques such as gray-level thresholding, region growing, andmore » manual drawing, in which each of segmented image slice was subsequently reviewed by an experienced radiologist for anatomical accuracy. The resulting phantoms, the MR-based KTMAN-1 (Korean Typical MAN-1) and the CT-based KTMAN-2 (Korean Typical MAN-2), consist of 300x150x344 voxels with a voxel resolution of 2x2x5 mm{sup 3} for both phantoms. Masses of segmented organs and tissues were calculated as the product of a nominal reference density, the prevoxel volume, and the cumulative number of voxels defining each organs or tissue. These organs masses were then compared with those of both the Asian and the ICRP reference adult male. Organ masses within both KTMAN-1 and KTMAN-2 showed differences within 40% of Asian and ICRP reference values, with the exception of the skin, gall bladder, and pancreas which displayed larger differences. The resulting three-dimensional binary file was ported to the Monte Carlo code MCNPX2.4 to calculate organ doses following external irradiation for illustrative purposes. Colon, lung, liver, and stomach absorbed doses, as well as the effective dose, for idealized photon irradiation geometries (anterior-posterior and right lateral) were determined, and then compared with data from two other tomographic phantoms (Asian and Caucasian), and stylized ORNL phantom. The armless KTMAN-1 can be applied to dosimetry for computed tomography or lateral x-ray examination, while the whole body KTMAN-2 can be used for radiation protection dosimetry.« less
Earthquake Parameters Inferred from the Hoping River Pseudotachylyte, Taiwan
NASA Astrophysics Data System (ADS)
Korren, C.; Ferre, E. C.; Yeh, E. C.; Chou, Y. M.
2014-12-01
Taiwan, one of the most seismically active areas in the world, repeatedly experiences violent earthquakes, such as the 1999 Mw 7.6 Chi-Chi earthquake, in highly populated areas. The main island of Taiwan lies in the convergent tectonic region between the Eurasian Plate and Philippine Sea Plate. Fault pseudotachylytes form by frictional melting along the fault plane during large seismic slip events and therefore constitute earthquake fossils. The width of a pseudotachylyte generation vein is a crude proxy for earthquake magnitude. The attitude of oblique injection veins primarily reflects slip kinematics. Additional constraints on the seismic slip direction and slip sense can be obtained 1) from the principal axes of the magnetic fabric of generation veins and 2) from 3D tomographic analysis of vein geometry. A new pseudotachylyte locality discovered along the Hoping River offers an unparalleled opportunity to learn more about the Plio-Pleistocene paleoseismology and seismic kinematics of northeastern Taiwan. Field work measured the orientations and relations of structural features yields a complex geometry of generation and injection veins. Pseudotachylytes were sampled for tomographic, magnetic fabric and scanning electron microscope analyses. An oriented block of pseudotachylyte was sliced then stitched into a 3-D tomographic model using the Image-J software image stack plug-in. Tomographic analysis shows pseudotachylyte veins originate from a single slip event at sample size. An average vein thickness ranges from 1 mm proximal to areas with abundant injection veins to 2 mm. The displacement calculated after Sibson's 1975 method, displacement equals the square of vein thickness multiplied by 436 yields a range from 4.36 cm to 17.44 cm. The pseudotachylytes displacement typifies earthquakes less than magnitude 5. However, this crude estimate of displacement requires further discussion. Comparison of the calculated displacements by different methodology may further constrain the values. Improving the accuracy of parameters pertaining to depth, pressure and temperature conditions, faulting style and coseismic fluids will vastly affect these displacement values. Aspects of focal mechanism determination leads to a more comprehensive assessment of both prehistoric and modern seismic risk.
Crotty, Dominic J; Brady, Samuel L; Jackson, D'Vone C; Toncheva, Greta I; Anderson, Colin E; Yoshizumi, Terry T; Tornai, Martin P
2011-06-01
A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.
Crotty, Dominic J.; Brady, Samuel L.; Jackson, D’Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.
2011-01-01
Purpose: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Methods: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Results: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Conclusions: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging. PMID:21815398
Primate Brain Anatomy: New Volumetric MRI Measurements for Neuroanatomical Studies.
Navarrete, Ana F; Blezer, Erwin L A; Pagnotta, Murillo; de Viet, Elizabeth S M; Todorov, Orlin S; Lindenfors, Patrik; Laland, Kevin N; Reader, Simon M
2018-06-12
Since the publication of the primate brain volumetric dataset of Stephan and colleagues in the early 1980s, no major new comparative datasets covering multiple brain regions and a large number of primate species have become available. However, technological and other advances in the last two decades, particularly magnetic resonance imaging (MRI) and the creation of institutions devoted to the collection and preservation of rare brain specimens, provide opportunities to rectify this situation. Here, we present a new dataset including brain region volumetric measurements of 39 species, including 20 species not previously available in the literature, with measurements of 16 brain areas. These volumes were extracted from MRI of 46 brains of 38 species from the Netherlands Institute of Neuroscience Primate Brain Bank, scanned at high resolution with a 9.4-T scanner, plus a further 7 donated MRI of 4 primate species. Partial measurements were made on an additional 8 brains of 5 species. We make the dataset and MRI scans available online in the hope that they will be of value to researchers conducting comparative studies of primate evolution. © 2018 S. Karger AG, Basel.
Accelerated Brain Aging in Schizophrenia: A Longitudinal Pattern Recognition Study.
Schnack, Hugo G; van Haren, Neeltje E M; Nieuwenhuis, Mireille; Hulshoff Pol, Hilleke E; Cahn, Wiepke; Kahn, René S
2016-06-01
Despite the multitude of longitudinal neuroimaging studies that have been published, a basic question on the progressive brain loss in schizophrenia remains unaddressed: Does it reflect accelerated aging of the brain, or is it caused by a fundamentally different process? The authors used support vector regression, a supervised machine learning technique, to address this question. In a longitudinal sample of 341 schizophrenia patients and 386 healthy subjects with one or more structural MRI scans (1,197 in total), machine learning algorithms were used to build models to predict the age of the brain and the presence of schizophrenia ("schizophrenia score"), based on the gray matter density maps. Age at baseline ranged from 16 to 67 years, and follow-up scans were acquired between 1 and 13 years after the baseline scan. Differences between brain age and chronological age ("brain age gap") and between schizophrenia score and healthy reference score ("schizophrenia gap") were calculated. Accelerated brain aging was calculated from changes in brain age gap between two consecutive measurements. The age prediction model was validated in an independent sample. In schizophrenia patients, brain age was significantly greater than chronological age at baseline (+3.36 years) and progressively increased during follow-up (+1.24 years in addition to the baseline gap). The acceleration of brain aging was not constant: it decreased from 2.5 years/year just after illness onset to about the normal rate (1 year/year) approximately 5 years after illness onset. The schizophrenia gap also increased during follow-up, but more pronounced variability in brain abnormalities at follow-up rendered this increase nonsignificant. The progressive brain loss in schizophrenia appears to reflect two different processes: one relatively homogeneous, reflecting accelerated aging of the brain and related to various measures of outcome, and a more variable one, possibly reflecting individual variation and medication use. Differentiating between these two processes may not only elucidate the various factors influencing brain loss in schizophrenia, but also assist in individualizing treatment.
Volumetry of human taste buds using laser scanning microscopy.
Just, T; Srur, E; Stachs, O; Pau, H W
2009-10-01
In vivo laser scanning confocal microscopy is a relatively new, non-invasive method for assessment of oral cavity epithelia. The penetration depth of approximately 200-400 microm allows visualisation of fungiform papillae and their taste buds. This paper describes the technique of in vivo volumetry of human taste buds. Confocal laser scanning microscopy used a diode laser at 670 nm for illumination. Digital laser scanning confocal microscopy equipment consisted of the Heidelberg Retina Tomograph HRTII and the Rostock Cornea Module. Volume scans of fungiform papillae were used for three-dimensional reconstruction of the taste bud. This technique supplied information on taste bud structure and enabled measurement and calculation of taste bud volume. Volumetric data from a 23-year-old man over a nine-day period showed only a small deviation in values. After three to four weeks, phenomenological changes in taste bud structures were found (i.e. a significant increase in volume, followed by disappearance of the taste bud and appearance of a new taste bud). The data obtained indicate the potential application of this non-invasive imaging modality: to evaluate variation of taste bud volume in human fungiform papillae with ageing; to study the effects of chorda tympani nerve transection on taste bud volume; and to demonstrate recovery of taste buds in patients with a severed chorda tympani nerve who show recovery of gustatory sensibility after surgery.
Gonzalo, Irene T Gaw; Itti, Emmanuel; Mlikotic, Anton; Pham, Le H; Cesar, Romeo B; Meignan, Michel; Mishkin, Fred S
2003-01-01
To evaluate the feasibility of using [(18)F]fluorodeoxyglucose ((18)FDG) triple-head coincidence imaging as a potential cost-effective alternative to positron emission tomography in the setting of suspected recurrence of papillary thyroid carcinoma. We retrospectively studied 10 patients with suspected recurrence of papillary carcinoma of the thyroid, who underwent (18)FDG coincidence imaging,(131)I scanning, and a reference anatomic scan (computed tomography, magnetic resonance imaging, or both) within 1 year in most cases. The (131)I scan detected the recurrence in five patients (62.5%) and failed to reveal recurrent cancer in three patients (37.5%); in contrast,(18)FDG imaging detected the recurrence in eight patients (100%) and was true negative in two patients in whom the scans were performed more than 1 year after effective therapy for the recurrence. The sensitivity of detection was unrelated to lesion size. The (18)FDG imaging results led to additional radiotherapy in all (131)I-negative patients, two of whom had high thyroglobulin levels and one of whom had a low thyroglobulin concentration but the presence of antithy-roglobulin antibodies. We conclude that (18)FDG triple-head coincidence imaging is useful for routine management of patients with thyroid cancer who have no abnormalities detected on (131)I scans but have high serum thyroglobulin levels. This technique, however, may not be as sensitive as a dedicated positron emission tomographic device, particularly for the assessment of small tumors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.
1989-06-01
The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less
An unusual presentation of carcinomatous meningitis
Foo, Chuan T.; Burrell, Louise M.; Johnson, Douglas F.
2016-01-01
A 67-year old previously well male presented with a 1 week history of confusion on a background of 3 weeks of headache. Past history included two superficial melanomas excised 5 years ago. Treatment for meningoencephalitis was commenced based on lumbar puncture (LP) and non-contrast brain magnetic resonance imaging (MRI) results. Lack of a clinical response to antibiotics resulted in a second LP and contrast brain MRI which demonstrated hydrocephalus and leptomeningeal disease. Ongoing deterioration led to a whole-body computed tomographic and spinal MRI that showed widespread metastatic disease and extensive leptomeningeal involvement of the spinal cord. The diagnosis of metastatic melanoma with carcinomatous meningitis was made based on cytological analysis of cerebrospinal fluid. He died 2 weeks later in a palliative care facility. This case illustrates that the diagnosis of carcinomatous meningitis can be difficult to make as the heterogeneous nature of its presentation often delays the diagnosis. PMID:27574561
Ueno, Hiroki; Kobatake, Keitaro; Matsumoto, Masayasu; Morino, Hiroyuki; Maruyama, Hirofumi; Kawakami, Hideshi
2011-12-12
Previous studies have shown widespread multisystem degeneration in patients with sporadic amyotrophic lateral sclerosis who develop a total locked-in state and survive under mechanical ventilation for a prolonged period of time. However, the disease progressions reported in these studies were several years after disease onset. There have been no reports of long-term follow-up with brain imaging of patients with familial amyotrophic lateral sclerosis at an advanced stage of the disease. We report the cases of siblings with amyotrophic lateral sclerosis with homozygous deletions of the exon 5 mutation of the gene encoding optineurin, in whom brain computed tomography scans were followed up for more than 20 years. The patients were a Japanese brother and sister. The elder sister was 33 years of age at the onset of disease, which began with muscle weakness of her left lower limb. Two years later she required mechanical ventilation. She became bedridden at the age of 34, and died at the age of 57. A computed tomography scan of her brain at the age of 36 revealed no abnormality. Atrophy of her brain gradually progressed. Ten years after the onset of mechanical ventilation, atrophy of her whole brain, including the cerebral cortex, brain stem and cerebellum, markedly progressed. Her younger brother was 36 years of age at the onset of disease, which presented as muscle weakness of his left upper limb. One year later, he showed dysphagia and dysarthria, and tracheostomy ventilation was performed. He became bedridden at the age of 37 and died at the age of 55. There were no abnormal intracranial findings on brain computed tomography scans obtained at the age of 37 years. At the age of 48 years, computed tomography scans showed marked brain atrophy with ventricular dilatation. Subsequently, atrophy of the whole brain rapidly progressed as in his elder sister. We conclude that a homozygous deletion-type mutation in the optineurin gene may be associated with widespread multisystem degeneration in amyotrophic lateral sclerosis.
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alva-Sánchez, Héctor, E-mail: halva@ciencias.unam.mx; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guidemore » provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.« less
Patient dose estimation from CT scans at the Mexican National Neurology and Neurosurgery Institute
NASA Astrophysics Data System (ADS)
Alva-Sánchez, Héctor; Reynoso-Mejía, Alberto; Casares-Cruz, Katiuzka; Taboada-Barajas, Jesús
2014-11-01
In the radiology department of the Mexican National Institute of Neurology and Neurosurgery, a dedicated institute in Mexico City, on average 19.3 computed tomography (CT) examinations are performed daily on hospitalized patients for neurological disease diagnosis, control scans and follow-up imaging. The purpose of this work was to estimate the effective dose received by hospitalized patients who underwent a diagnostic CT scan using typical effective dose values for all CT types and to obtain the estimated effective dose distributions received by surgical and non-surgical patients. Effective patient doses were estimated from values per study type reported in the applications guide provided by the scanner manufacturer. This retrospective study included all hospitalized patients who underwent a diagnostic CT scan between 1 January 2011 and 31 December 2012. A total of 8777 CT scans were performed in this two-year period. Simple brain scan was the CT type performed the most (74.3%) followed by contrasted brain scan (6.1%) and head angiotomography (5.7%). The average number of CT scans per patient was 2.83; the average effective dose per patient was 7.9 mSv; the mean estimated radiation dose was significantly higher for surgical (9.1 mSv) than non-surgical patients (6.0 mSv). Three percent of the patients had 10 or more brain CT scans and exceeded the organ radiation dose threshold set by the International Commission on Radiological Protection for deterministic effects of the eye-lens. Although radiation patient doses from CT scans were in general relatively low, 187 patients received a high effective dose (>20 mSv) and 3% might develop cataract from cumulative doses to the eye lens.
High prevalence of brain pathology in violent prisoners: a qualitative CT and MRI scan study.
Schiltz, Kolja; Witzel, Joachim G; Bausch-Hölterhoff, Josef; Bogerts, Bernhard
2013-10-01
The aim of this study was to determine the frequency and extent of brain anomalies in a large sample of incarcerated violent offenders not previously considered neuropsychiatrically ill, in comparison with non-violent offenders and non-offending controls. MRI and CT brain scans from 287 male prison inmates (162 violent and 125 non-violent) not diagnosed as mentally ill before that were obtained due to headache, vertigo or psychological complaints during imprisonment were assessed and compared to 52 non-criminal controls. Brain scans were rated qualitatively with respect to evidence of structural brain damage. Each case received a semiquantitative rating of "normal" (=0), "questionably abnormal" (=1) or "definitely abnormal" (=2) for the lateral ventricles, frontal/parietal cortex and medial temporal structures bilaterally as well as third ventricle. Overall, offenders displayed a significantly higher rate of morphological abnormality, with the violent offenders scoring significantly higher than non-violent offenders and controls. This difference was statistically detectable for frontal/parietal cortex, medial temporal structures, third ventricle and the left but not the right lateral ventricle. The remarkable prevalence of brain pathology in convicted violent prisoners detectable by neuroradiological routine assessment not only highlights the importance of frontal and temporal structures in the control of social, and specifically of violent behaviour, but also raises questions on the legal culpability of violent offenders with brain abnormalities. The high proportion of undetected presence of structural brain damage emphasizes the need that in violent criminals, the comprehensive routine neuropsychiatric assessment usually performed in routine forensic psychiatric expertises should be complemented with brain imaging.
Sosin, Michael; Ceradini, Daniel J; Hazen, Alexes; Sweeney, Nicole G; Brecht, Lawrence E; Levine, Jamie P; Staffenberg, David A; Saadeh, Pierre B; Bernstein, G Leslie; Rodriguez, Eduardo D
2016-05-01
Cadaveric face transplant models are routinely used for technical allograft design, perfusion assessment, and transplant simulation but are associated with substantial limitations. The purpose of this study was to describe the experience of implementing a translational donor research facial procurement and solid organ allograft recovery model. Institutional review board approval was obtained, and a 49-year-old, brain-dead donor was identified for facial vascularized composite allograft research procurement. The family generously consented to donation of solid organs and the total face, eyelids, ears, scalp, and skeletal subunit allograft. The successful sequence of computed tomographic scanning, fabrication and postprocessing of patient-specific cutting guides, tracheostomy placement, preoperative fluorescent angiography, silicone mask facial impression, donor facial allograft recovery, postprocurement fluorescent angiography, and successful recovery of kidneys and liver occurred without any donor instability. Preservation of the bilateral external carotid arteries, facial arteries, occipital arteries, and bilateral thyrolinguofacial and internal jugular veins provided reliable and robust perfusion to the entirety of the allograft. Total time of facial procurement was 10 hours 57 minutes. Essential to clinical face transplant outcomes is the preparedness of the institution, multidisciplinary face transplant team, organ procurement organization, and solid organ transplant colleagues. A translational facial research procurement and solid organ recovery model serves as an educational experience to modify processes and address procedural, anatomical, and logistical concerns for institutions developing a clinical face transplantation program. This methodical approach best simulates the stressors and challenges that can be expected during clinical face transplantation. Therapeutic, V.
Newberg, Andrew B.; Serruya, Mijail; Gepty, Andrew; Intenzo, Charles; Lewis, Todd; Amen, Daniel; Russell, David S.; Wintering, Nancy
2014-01-01
Background This study evaluated the clinical interpretations of single photon emission computed tomography (SPECT) using a cerebral blood flow and a dopamine transporter tracer in patients with chronic mild traumatic brain injury (TBI). The goal was to determine how these two different scan might be used and compared to each other in this patient population. Methods and Findings Twenty-five patients with persistent symptoms after a mild TBI underwent SPECT with both 99mTc exametazime to measure cerebral blood flow (CBF) and 123I ioflupane to measure dopamine transporter (DAT) binding. The scans were interpreted by two expert readers blinded to any case information and were assessed for abnormal findings in comparison to 10 controls for each type of scan. Qualitative CBF scores for each cortical and subcortical region along with DAT binding scores for the striatum were compared to each other across subjects and to controls. In addition, symptoms were compared to brain scan findings. TBI patients had an average of 6 brain regions with abnormal perfusion compared to controls who had an average of 2 abnormal regions (p<0.001). Patient with headaches had lower CBF in the right frontal lobe, and higher CBF in the left parietal lobe compared to patients without headaches. Lower CBF in the right temporal lobe correlated with poorer reported physical health. Higher DAT binding was associated with more depressive symptoms and overall poorer reported mental health. There was no clear association between CBF and DAT binding in these patients. Conclusions Overall, both scans detected abnormalities in brain function, but appear to reflect different types of physiological processes associated with chronic mild TBI symptoms. Both types of scans might have distinct uses in the evaluation of chronic TBI patients depending on the clinical scenario. PMID:24475210
2009-01-01
Background Structural Magnetic Resonance Imaging (sMRI) of the brain is employed in the assessment of a wide range of neuropsychiatric disorders. In order to improve statistical power in such studies it is desirable to pool scanning resources from multiple centres. The CaliBrain project was designed to provide for an assessment of scanner differences at three centres in Scotland, and to assess the practicality of pooling scans from multiple-centres. Methods We scanned healthy subjects twice on each of the 3 scanners in the CaliBrain project with T1-weighted sequences. The tissue classifier supplied within the Statistical Parametric Mapping (SPM5) application was used to map the grey and white tissue for each scan. We were thus able to assess within scanner variability and between scanner differences. We have sought to correct for between scanner differences by adjusting the probability mappings of tissue occupancy (tissue priors) used in SPM5 for tissue classification. The adjustment procedure resulted in separate sets of tissue priors being developed for each scanner and we refer to these as scanner specific priors. Results Voxel Based Morphometry (VBM) analyses and metric tests indicated that the use of scanner specific priors reduced tissue classification differences between scanners. However, the metric results also demonstrated that the between scanner differences were not reduced to the level of within scanner variability, the ideal for scanner harmonisation. Conclusion Our results indicate the development of scanner specific priors for SPM can assist in pooling of scan resources from different research centres. This can facilitate improvements in the statistical power of quantitative brain imaging studies. PMID:19445668
Detection of Blast-Related Traumatic Brain Injury in U.S. Military Personnel
Mac Donald, Christine L.; Johnson, Ann M.; Cooper, Dana; Nelson, Elliot C.; Werner, Nicole J.; Shimony, Joshua S.; Snyder, Abraham Z.; Raichle, Marcus E.; Witherow, John R.; Fang, Raymond; Flaherty, Stephen F.; Brody, David L.
2011-01-01
BACKGROUND Blast-related traumatic brain injuries have been common in the Iraq and Afghanistan wars, but fundamental questions about the nature of these injuries remain unanswered. METHODS We tested the hypothesis that blast-related traumatic brain injury causes traumatic axonal injury, using diffusion tensor imaging (DTI), an advanced form of magnetic resonance imaging that is sensitive to axonal injury. The subjects were 63 U.S. military personnel who had a clinical diagnosis of mild, uncomplicated traumatic brain injury. They were evacuated from the field to the Landstuhl Regional Medical Center in Landstuhl, Germany, where they underwent DTI scanning within 90 days after the injury. All the subjects had primary blast exposure plus another, blast-related mechanism of injury (e.g., being struck by a blunt object or injured in a fall or motor vehicle crash). Controls consisted of 21 military personnel who had blast exposure and other injuries but no clinical diagnosis of traumatic brain injury. RESULTS Abnormalities revealed on DTI were consistent with traumatic axonal injury in many of the subjects with traumatic brain injury. None had detectible intracranial injury on computed tomography. As compared with DTI scans in controls, the scans in the subjects with traumatic brain injury showed marked abnormalities in the middle cerebellar peduncles (P<0.001), in cingulum bundles (P = 0.002), and in the right orbitofrontal white matter (P = 0.007). In 18 of the 63 subjects with traumatic brain injury, a significantly greater number of abnormalities were found on DTI than would be expected by chance (P<0.001). Follow-up DTI scans in 47 subjects with traumatic brain injury 6 to 12 months after enrollment showed persistent abnormalities that were consistent with evolving injuries. CONCLUSIONS DTI findings in U.S. military personnel support the hypothesis that blast-related mild traumatic brain injury can involve axonal injury. However, the contribution of primary blast exposure as compared with that of other types of injury could not be determined directly, since none of the subjects with traumatic brain injury had isolated primary blast injury. Furthermore, many of these subjects did not have abnormalities on DTI. Thus, traumatic brain injury remains a clinical diagnosis. (Funded by the Congressionally Directed Medical Research Program and the National Institutes of Health; ClinicalTrials.gov number, NCT00785304.) PMID:21631321
Mouse brain responses to charged particle radiation
NASA Astrophysics Data System (ADS)
Nelson, Gregory; Nelson, Gregory; Chang, Polly; Favre, Cecile; Fike, John; Mao, Xiao-Wen; Obenaus, Andre; Pecaut, Michael; Vlkolinsky, Roman; Song, Sheng-Kwei; Spigelman, Igor; Stampanoni, Marco
CHANGES IN DISEASE LATENCY AND HOMEOSTASIS: 1) APP23 transgenic mice exhibit many of the pathological features of Alzheimer's Disease, and the disease progression is continuous over several months. Electrophysiological measurements have shown that disease-related decreases in synaptic efficacy occur earlier in irradiated APP23 animals. 2) Using vascular polymer cast technology combined with micro-tomographic imaging, microvasculature changes following irradiation have been detected and are consistent with loss of vessels and an increased spacing between them. The time course of vessel changes to control and irradiated animals is being constructed. 3) In order to assess the ability of the brain to respond to external environmental shocks and restore orderly normal function (homeostasis), we apply a controlled septic shock by treating animals with lipopolysaccharide (LPS). We find that in irradiated animals, the patterns of electrophysiological changes associated with reactions to lipopolysaccharide (LPS) are complex and unlike those of either LPS or irradiation alone. They further suggest that the brain continues to remodel for up to 6 months following radiation. This is consistent with the idea that irradiation may potentiate the risks from late secondary insults.
Filpo-Perez, Carolina; Bramante, Clovis Monteiro; Villas-Boas, Marcelo Haas; Húngaro Duarte, Marco Antonio; Versiani, Marco Aurélio; Ordinola-Zapata, Ronald
2015-02-01
The aim of this study was to evaluate the morphologic aspects of the root canal anatomy of the distal root of a mandibular first molar using micro-computed tomographic analysis. One-hundred distal roots of mandibular first molars were scanned using a micro-computed tomographic device at an isotropic resolution of 19.6 μm. The percentage frequency distribution of the morphologic configuration of the root canal was performed according to the Vertucci classification system. Two-dimensional parameters (area, perimeter, roundness, aspect ratio, and major and minor diameters) and the cross-sectional shape of the root canal were analyzed in the apical third at every 1-mm interval from the main apical foramen in roots presenting Vertucci types I and II configurations (n = 79). Data were statistically compared using the Kruskal-Wallis and Dunn tests with a significance level set at 5%. Seventy-six percent of the distal roots had a single root canal. Two, three, and four canals were found in 13%, 8%, and 3% of the sample, respectively. In 13 specimens, the configuration of the root canal did not fit into Vertucci's classification. Overall, 2-dimensional parameter values significantly increased at the 3-mm level (P < .05). The prevalence of oval canals was higher at the 1-mm level and decreased at the 5-mm level in which long oval and flattened canals were more prevalent. The distal roots of the mandibular first molars showed a high prevalence of single root canals. The prevalence of long oval and flattened canals increased in the coronal direction. In 13% of the samples, canal configurations that were not included in Vertucci's configuration system were found. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Bühler, M; Fürst, A; Lewis, F I; Kummer, M; Ohlerth, S
2014-07-01
Computed tomographic (CT) studies evaluating the relevance of individual CT features of apical infection in maxillary cheek teeth are lacking. To study the prevalence and relationship of single CT features in horses with and without clinical evidence of apical infection in maxillary cheek teeth. Retrospective case-control study. Multislice CT scans of the head of 49 horses were evaluated retrospectively. Changes of the infundibulum, pulp, root, lamina dura, periodontal space and alveolar bone in maxillary cheek teeth were recorded. Single CT changes were much more prevalent in the 28 horses with clinical signs. However, infundibular changes and a nondetectable lamina dura were also common in the 21 horses without clinical evidence of apical infection. Computed tomographic abnormalities of the pulp, root, periapical bone and periodontal space and the presence of a tooth fracture were significantly related. Infundibular changes were not associated with other CT signs of apical infection. Although nondetectable lamina dura was the most frequent CT change in all teeth in both studied groups, it was most commonly a solitary feature in otherwise normal teeth. Apical infections, defined as ≥3 CT changes, occurred mainly in the 108/208, 109/209 and 110/210 (Triadan numbers) and were found only in horses with clinical evidence of apical infection, except in one horse without clinical signs that had one affected root. Combined CT changes of the pulp, root, lamina dura, periapical bone and periodontal space and the presence of a tooth fracture appear to be reliable features to diagnose apical infection in maxillary cheek teeth. As a solitary feature, a nondetectable lamina dura should be interpreted cautiously and may even be considered normal due to its minor thickness and/or too low resolution of the imaging modality. © 2013 EVJ Ltd.
de Oliveira, Bruna Paloma; Câmara, Andréa Cruz; Duarte, Daniel Amancio; Heck, Richard John; Antonino, Antonio Celso Dantas; Aguiar, Carlos Menezes
2017-07-01
This study aimed to compare apical microcrack formation after root canal shaping by hand, rotary, and reciprocating files at different working lengths using micro-computed tomographic analysis. Sixty mandibular incisors were randomly divided into 6 experimental groups (n = 10) according to the systems and working lengths used for the root canal preparation: ProTaper Universal for Hand Use (Dentsply Maillefer, Ballaigues, Switzerland), HyFlex CM (Coltene-Whaledent, Allstetten, Switzerland), and Reciproc (VDW, Munich, Germany) files working at the apical foramen (AF) and 1 mm short of the AF (AF - 1 mm). The teeth were imaged with micro-computed tomographic scanning at an isotropic resolution of 14 μm before and after root canal preparation, and the cross-sectional images generated were assessed to detect microcracks in the apical portion of the roots. Overall, 17 (28.3%) specimens presented microcracks before instrumentation. Apical microcracks were present in 1 (ProTaper Universal for Hand Use), 3 (Hyflex CM), and 2 (Reciproc) specimens when the instrumentation terminated at the AF. When instrumentation was terminated at AF - 1 mm, apical microcracks were detected in 3 (ProTaper Universal for Hand Use) and 4 (Hyflex CM and Reciproc) specimens. All these microcracks detected after root canal preparation were already present before instrumentation, and no new apical microcrack was visualized. For all groups, the number of slices presenting microcracks after root canal preparation was the same as before canal preparation. Root canal shaping with ProTaper Universal for Hand Use, HyFlex CM, and Reciproc systems, regardless of the working length, did not produce apical microcracks. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yuan, Fusong; Lv, Peijun; Yang, Huifang; Wang, Yong; Sun, Yuchun
2015-07-01
Objectives: Based on the pixel gray value measurements, establish a beam-hardening artifacts index of the cone-beam CT tomographic image, and preliminarily evaluate its applicability. Methods: The 5mm-diameter metal ball and resin ball were fixed on the light-cured resin base plate respectively, while four vitro molars were fixed above and below the ball, on the left and right respectively, which have 10mm distance with the metal ball. Then, cone beam CT was used to scan the fixed base plate twice. The same layer tomographic images were selected from the two data and imported into the Photoshop software. The circle boundary was built through the determination of the center and radius of the circle, according to the artifact-free images section. Grayscale measurement tools were used to measure the internal boundary gray value G0, gray value G1 and G2 of 1mm and 20mm artifacts outside the circular boundary, the length L1 of the arc with artifacts in the circular boundary, the circumference L2. Hardening artifacts index was set A = (G1 / G0) * 0.5 + (G2 / G1) * 0.4 + (L2 / L1) * 0.1. Then, the A values of metal and resin materials were calculated respectively. Results: The A value of cobalt-chromium alloy material is 1, and resin material is 0. Conclusion: The A value reflects comprehensively the three factors of hardening artifacts influencing normal oral tissue image sharpness of cone beam CT. The three factors include relative gray value, the decay rate and range of artifacts.
Bayram, H Melike; Bayram, Emre; Ocak, Mert; Uygun, Ahmet Demirhan; Celik, Hakan Hamdi
2017-07-01
The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Tulsa, OK), ProTaper Gold (PTG; Dentsply Tulsa Dental Specialties), Self-Adjusting File (SAF; ReDent Nova, Ra'anana, Israel), and XP-endo Shaper (XP; FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments using micro-computed tomographic (CT) analysis. Forty extracted human mandibular premolars having single-canal and straight root were randomly assigned to 4 experimental groups (n = 10) according to the different nickel-titanium systems used for root canal preparation: PTU, PTG, SAF, and XP. In the SAF and XP groups, the canals were first prepared with a K-file until #25 at the working length, and then the SAF or XP files were used. The specimens were scanned using high-resolution micro-computed tomographic imaging before and after root canal preparation. Afterward, preoperative and postoperative cross-sectional images of the teeth were screened to identify the presence of dentinal defects. For each group, the number of microcracks was determined as a percentage rate. The McNemar test was used to determine significant differences before and after instrumentation. The level of significance was set at P ≤ .05. The PTU system significantly increased the percentage rate of microcracks compared with preoperative specimens (P < .05). No new dentinal microcracks were observed in the PTG, SAF, or XP groups. Root canal preparations with the PTG, SAF, and XP systems did not induce the formation of new dentinal microcracks on straight root canals of mandibular premolars. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Anolik, Rachel A; Allori, Alexander C; Pourtaheri, Navid; Rogers, Gary F; Marcus, Jeffrey R
2016-05-01
The purpose of this study was to evaluate the utility of a previously validated interfrontal angle for classification of severity of metopic synostosis and as an aid to operative decision-making. An expert panel was asked to study 30 cases ranging from minor to severe metopic synostosis. Based on computed tomographic images of the skull and clinical photographs, they classified the severity of trigonocephaly (1 = normal, 2 = mild, 3 = moderate, and 4 = severe) and management (0 = nonoperative and 1 = operative). The severity scores and management reported by experts were then pooled and matched with the interfrontal angle computed from each respective computed tomographic scan. A threshold was identified at which most experts agree on operative management. Expert severity scores were higher for more acute interfrontal angles. There was a high concordance at the extremes of classifications, severe (4) and normal (1) (p < 0.0001); however, between interfrontal angles of 114.3 and 136.1 degrees, there exists a "gray zone," with severe discordance in expert rankings. An operative threshold of 118.2 degrees was identified, with the interfrontal angle able to predict the expert panel's decision to proceed with surgery 87.6 percent of the time. The interfrontal angle has been previously validated as a simple, accurate, and reproducible means for diagnosing trigonocephaly, but must be obtained from computed tomographic data. In this article, the authors demonstrate that the interfrontal angle can be used to further characterize the severity of trigonocephaly. It also correlated with expert decision-making for operative versus nonoperative management. This tool may be used as an adjunct to clinical decision-making when the decision to proceed with surgery may not be straightforward. Diagnostic, V.
Assessing stapes piston position using computed tomography: a cadaveric study.
Hahn, Yoav; Diaz, Rodney; Hartman, Jonathan; Bobinski, Matthew; Brodie, Hilary
2009-02-01
Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.
Aidoud, Nacima; Delplanque, Bernadette; Baudry, Charlotte; Garcia, Cyrielle; Moyon, Anais; Balasse, Laure; Guillet, Benjamin; Antona, Claudine; Darmaun, Dominique; Fraser, Karl; Ndiaye, Sega; Leruyet, Pascale; Martin, Jean-Charles
2018-03-22
We evaluated the effect of adding docosahexaenoic:arachidonic acids (3:2) (DHA+ARA) to 2 representative commercial infant formulas on brain activity and brain and eye lipids in an artificially reared rat pup model. The formula lipid background was either a pure plant oil blend, or dairy fat with a plant oil blend (1:1). Results at weaning were compared to breast milk-fed pups. Brain functional activity was determined by positron emission tomography scan imaging, the brain and eye fatty acid and lipid composition by targeted and untargeted lipidomics, and DHA brain regional location by mass-spectrometry imaging. The brain functional activity was normalized to controls with DHA+ARA added to the formulas. DHA in both brain and eyes was influenced by formula intake, but more than two-thirds of tissue DHA-glycerolipids remained insensitive to the dietary challenge. However, the DHA lipidome correlated better with brain function than sole DHA content ( r = 0.70 vs. r = 0.48; P < 0.05). Brain DHA regional distribution was more affected by the formula lipid background than the provision of PUFAs. Adding DHA+ARA to formulas alters the DHA content and lipidome of nervous tissue in the neonate, making it closer to dam milk-fed controls, and normalizes brain functional activity.-Aidoud, N., Delplanque, B., Baudry, C., Garcia, C., Moyon, A., Balasse, L., Guillet, B., Antona, C., Darmaun, D., Fraser, K., Ndiaye, S., Leruyet, P., Martin, J.-C. A combination of lipidomics, MS imaging, and PET scan imaging reveals differences in cerebral activity in rat pups according to the lipid quality of infant formulas.
A regularized clustering approach to brain parcellation from functional MRI data
NASA Astrophysics Data System (ADS)
Dillon, Keith; Wang, Yu-Ping
2017-08-01
We consider a data-driven approach for the subdivision of an individual subject's functional Magnetic Resonance Imaging (fMRI) scan into regions of interest, i.e., brain parcellation. The approach is based on a computational technique for calculating resolution from inverse problem theory, which we apply to neighborhood selection for brain connectivity networks. This can be efficiently calculated even for very large images, and explicitly incorporates regularization in the form of spatial smoothing and a noise cutoff. We demonstrate the reproducibility of the method on multiple scans of the same subjects, as well as the variations between subjects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lassen, N.A.; Henriksen, L.; Holm, S.
1983-01-01
Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used. The Xe-133 flow maps are essentially based on the average Xe-133 concentration over the initial 2 min during and after an inhalation of the inert gas lasting 1 min. These maps agreed very well with the early IMP maps obtained over the initial 10 min following an i.v. bolus injection. The subsequent IMP tomograms showed a slight decrease in contrast amountingmore » to appr. five percentage points in the CBF ratio between diseased and contralateral areas. It is concluded that Xe-133 is more practical: low cost, available on a 7-day basis, easily repeatable, quantifiable without the need for arterial sampling, and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.« less
In vivo tomographic imaging of deep seated cancer using fluorescence lifetime contrast
Rice, William L.; Shcherbakova, Daria M; Verkusha, Vladislav V.; Kumar, Anand T.N.
2015-01-01
Preclinical cancer research would benefit from non-invasive imaging methods that allow tracking and visualization of early stage metastasis in vivo. While fluorescent proteins revolutionized intravital microscopy, two major challenges which still remain are tissue autofluorescence and hemoglobin absorption, which act to limit intravital optical techniques to large or subcutaneous tumors. Here we employ time-domain technology for the effective separation of tissue autofluorescence from extrinsic fluorophores, based on their distinct fluorescence lifetimes. Additionally, we employ cancer cells labelled with near infra-red fluorescent proteins (iRFP) to allow deep-tissue imaging. Our results demonstrate that time-domain imaging allows the detection of metastasis in deep-seated organs of living mice with a more than 20-fold increase in sensitivity compared to conventional continuous wave techniques. Furthermore, the distinct fluorescence lifetimes of each iRFP enables lifetime multiplexing of three different tumors, each expressing unique iRFP labels in the same animal. Fluorescence tomographic reconstructions reveal 3D distributions of iRFP720-expressing cancer cells in lungs and brain of live mice, allowing ready longitudinal monitoring of cancer cell fate with greater sensitivity than otherwise currently possible. PMID:25670171
Griffiths, Silja Torvik; Aukland, Stein Magnus; Markestad, Trond; Eide, Geir Egil; Elgen, Irene; Craven, Alexander R; Hugdahl, Kenneth
2014-10-01
The purpose of the study was to investigate a possible association between brain activation in functional magnetic resonance imaging scans, cognition and school performance in extremely preterm children and term born controls. Twenty eight preterm and 28 term born children were scanned while performing a working memory/selective attention task, and school results from national standardized tests were collected. Brain activation maps reflected difference in cognitive skills but not in school performance. Differences in brain activation were found between children born preterm and at term, and between high and low performers in cognitive tests. However, the differences were located in different brain areas. The implication may be that lack of cognitive skills does not alone explain low performance due to prematurity. © 2014 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
Ruptured intracranial dermoid: an unusual cause of headache in an older patient.
Rajapakse, Anoja; Diack, Alison
2008-02-01
A 76-year-old woman with a history of migraine presented with worsening headache. Computerized tomography brain scan and magnetic resonance imaging brain scan showed the presence of fat globules in the cerebrospinal fluid space. This appearance was suggestive of ruptured intracranial dermoid. She recovered spontaneously. While headache is a known presentation of ruptured intracranial dermoid, the condition is unusual to present in older people.
Bauer, Martin; Karch, Rudolf; Zeitlinger, Markus; Philippe, Cécile; Römermann, Kerstin; Stanek, Johann; Maier-Salamon, Alexandra; Wadsak, Wolfgang; Jäger, Walter; Hacker, Marcus; Müller, Markus; Langer, Oliver
2015-05-01
As P-glycoprotein (Pgp) inhibition at the blood-brain barrier (BBB) after administration of a single dose of tariquidar is transient, we performed positron emission tomography (PET) scans with the Pgp substrate (R)-[(11)C]verapamil in five healthy volunteers during continuous intravenous tariquidar infusion. Total distribution volume (VT) of (R)-[(11)C]verapamil in whole-brain gray matter increased by 273 ± 78% relative to baseline scans without tariquidar, which was higher than previously reported VT increases. During tariquidar infusion whole-brain VT was comparable to VT in the pituitary gland, a region not protected by the BBB, which suggested that we were approaching complete Pgp inhibition at the human BBB.
Brain-Based Learning. Research Brief
ERIC Educational Resources Information Center
Walker, Karen
2005-01-01
What does brain-based research say about how adolescents learn? The 1990s was declared as the Decade of the Brain by President Bush and Congress. With the advancement of MRIs (Magnetic Resonance Imagining) and PET (positron emission tomography) scans, it has become much easier to study live healthy brains. As a result, the concept of…
Nikolaoul, Marinos; Stamenković, Srdjan; Stergiou, Christos; Skarleas, Christos; Torrens, Michael
2015-01-01
Brain metastases from epithelial ovarian cancer (EOC) are rare events. We present a rare case of single ovarian cancer metastasis to the brain treated with gamma-knife radiosurgery (GKRS). A 65-year-old woman with advanced EOC presented with severe neurologic symptoms. A single brain metastasis of 3.2 cm with surrounding edema in the left parietal lobe was detected by brain magnetic resonance imaging (MRI) scan during the work-up. The decision to perform GKRS was due to a surgical inaccessibility of intracranial lesion. Twelve weeks after the procedure, the MRI scan showed reduction in the diameter of brain metastasis and surrounding edema and the patient returned to good mental and motor performance.The patient survived for 22 months following treatment and died from a progressive intra-abdominal disease. Prognosis of ovarian cancer patients with brain metastases is generally poor regardless of treatment. Our case shows that GKRS as primary treatment modality for the control of ovarian cancer metastases to the brain was effective and can be considered as a treatment of choice if international selection criteria are followed.
Use of Video Goggles to Distract Patients During PET/CT Studies of School-Aged Children.
Gelfand, Michael J; Harris, Jennifer M; Rich, Amanda C; Kist, Chelsea S
2016-12-01
This study was designed to evaluate the effectiveness of video goggles in distracting children undergoing PET/CT and to determine whether the goggles create CT and PET artifacts. Video goggles with small amounts of internal radioopaque material were used. During whole-body PET/CT imaging, 30 nonsedated patients aged 4-13 y watched videos of their choice using the goggles. Fifteen of the PET/CT studies were performed on a scanner installed in 2006, and the other 15 were performed on a scanner installed in 2013. The fused scans were reviewed for evidence of head movement, and the individual PET and CT scans of the head were reviewed for the presence and severity of streak artifact. The CT exposure settings were recorded for each scan at the anatomic level at which the goggles were worn. Only one of the 30 scans had evidence of significant head motion. Two of the 30 had minor coregistration problems due to motion, and 27 of the 30 had very good to excellent coregistration. For the 2006 scanner, 2 of the 14 evaluable localization CT scans of the head demonstrated no streak artifact in brain tissue, 6 of the 14 had mild streak artifact in brain tissue, and 6 of the 14 had moderate streak artifact in brain tissue. Mild streak artifact in bone was noted in 2 of the 14 studies. For the 2013 scanner, 7 of 15 studies had mild streak artifact in brain tissue and 8 of 15 had no streak artifact in brain tissue, whereas none of the 15 had streak artifact in bone. There were no artifacts attributable to the goggles on the 18 F-FDG PET brain images of any of the 29 evaluable studies. The average CT exposure parameters at the level of the orbits were 36% lower on the 2013 scanner than on the 2006 scanner. Video goggles may be used successfully to distract children undergoing PET with localization CT. The goggles cause no significant degradation of the PET brain images or the CT skull images. The degree of artifact on brain tissue images varies from none to moderate and depends on the CT equipment used. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
O’Connor, David; Potler, Natan Vega; Kovacs, Meagan; Xu, Ting; Ai, Lei; Pellman, John; Vanderwal, Tamara; Parra, Lucas C.; Cohen, Samantha; Ghosh, Satrajit; Escalera, Jasmine; Grant-Villegas, Natalie; Osman, Yael; Bui, Anastasia; Craddock, R. Cameron
2017-01-01
Abstract Background: Although typically measured during the resting state, a growing literature is illustrating the ability to map intrinsic connectivity with functional MRI during task and naturalistic viewing conditions. These paradigms are drawing excitement due to their greater tolerability in clinical and developing populations and because they enable a wider range of analyses (e.g., inter-subject correlations). To be clinically useful, the test-retest reliability of connectivity measured during these paradigms needs to be established. This resource provides data for evaluating test-retest reliability for full-brain connectivity patterns detected during each of four scan conditions that differ with respect to level of engagement (rest, abstract animations, movie clips, flanker task). Data are provided for 13 participants, each scanned in 12 sessions with 10 minutes for each scan of the four conditions. Diffusion kurtosis imaging data was also obtained at each session. Findings: Technical validation and demonstrative reliability analyses were carried out at the connection-level using the Intraclass Correlation Coefficient and at network-level representations of the data using the Image Intraclass Correlation Coefficient. Variation in intrinsic functional connectivity across sessions was generally found to be greater than that attributable to scan condition. Between-condition reliability was generally high, particularly for the frontoparietal and default networks. Between-session reliabilities obtained separately for the different scan conditions were comparable, though notably lower than between-condition reliabilities. Conclusions: This resource provides a test-bed for quantifying the reliability of connectivity indices across subjects, conditions and time. The resource can be used to compare and optimize different frameworks for measuring connectivity and data collection parameters such as scan length. Additionally, investigators can explore the unique perspectives of the brain's functional architecture offered by each of the scan conditions. PMID:28369458
Enoxaparin-induced spontaneous massive retroperitoneal hematoma with fatal outcome.
Salemis, Nikolaos S; Oikonomakis, Ioannis; Lagoudianakis, Emanuel; Boubousis, Georgios; Tsakalakis, Christos; Sourlas, Sotirios; Gourgiotis, Stavros
2014-12-01
Spontaneous retroperitoneal hematoma (SRH) is a severe and potentially fatal complication of anticoagulation therapy. We describe a case of fatal spontaneous massive retroperitoneal hematoma in a female patient receiving bridging therapy with enoxaparin for atrial fibrillation. Physicians should be cautious when prescribing enoxaparin in elderly patients, in patients with impaired renal function, and in patients receiving concomitant oral anticoagulants. Emergency physicians should always consider SRH in the differential diagnosis in patients under enoxaparin therapy presenting with abdominal pain. Computed tomographic scan is the imaging modality of choice for evaluating SRH. Early diagnosis and aggressive treatment are of paramount importance as SRH is associated with high mortality and morbidity rates.
Zaman, Taufiq; Watson, Joseph; Zaman, Mohammad
2017-01-01
Crohn disease is an immune-mediated inflammatory condition with gastrointestinal and extraintestinal manifestations in patients. Pulmonary involvement of Crohn disease is one manifestation. There have been case reports which have shown Crohn disease and lung nodules which were noted to be histopathological as cryptogenic organizing pneumonia (COP). In our case, a 22-year-old woman with Crohn disease was seen with complaints of chest pain and cough. Computed tomographic scan of chest showed multiple bilateral lung nodules, for which biopsy was done, which showed COP. The case study is followed by a deeper discussion of COP and the extraintestinal manifestation seen in inflammatory bowel disease.
Downstream Fabry-Perot interferometer for acoustic wave monitoring in photoacoustic tomography.
Nuster, Robert; Gruen, Hubert; Reitinger, Bernhard; Burgholzer, Peter; Gratt, Sibylle; Passler, Klaus; Paltauf, Guenther
2011-03-15
An optical detection setup consisting of a focused laser beam fed into a downstream Fabry-Perot interferometer (FPI) for demodulation of acoustically generated optical phase variations is investigated for its applicability in photoacoustic tomography. The device measures the time derivative of acoustic signals integrated along the beam. Compared to a setup where the detection beam is part of a Mach-Zehnder interferometer, the signal-to-noise ratio of the FPI is lower, but the image quality of the two devices is similar. Using the FPI in a photoacoustic tomograph allows scanning the probe beam around the imaging object without moving the latter.
Sekine, J; Irie, A; Dotsu, H; Inokuchi, T
2000-10-01
This report describes a case of bilateral pneumothorax with extensive subcutaneous emphysema in a 45-year-old man that occurred during surgery to extract the left lower third molar, performed with the use of an air turbine dental handpiece. Computed tomographic scanning showed severe subcutaneous emphysema extending bilaterally from the cervicofacial region and the deep anatomic spaces (including the pterygomandibular, parapharyngeal, retropharyngeal, and deep temporal spaces) to the anterior wall of the chest. Furthermore, bilateral pneumothorax and pneumomediastinum were present. In our patient, air dissection was probably caused by pressurized air being forced through the operating site into the surrounding connective tissue.
Three-dimensional ophthalmic optical coherence tomography with a refraction correction algorithm
NASA Astrophysics Data System (ADS)
Zawadzki, Robert J.; Leisser, Christoph; Leitgeb, Rainer; Pircher, Michael; Fercher, Adolf F.
2003-10-01
We built an optical coherence tomography (OCT) system with a rapid scanning optical delay (RSOD) line, which allows probing full axial eye length. The system produces Three-dimensional (3D) data sets that are used to generate 3D tomograms of the model eye. The raw tomographic data were processed by an algorithm, which is based on Snell"s law to correct the interface positions. The Zernike polynomials representation of the interfaces allows quantitative wave aberration measurements. 3D images of our results are presented to illustrate the capabilities of the system and the algorithm performance. The system allows us to measure intra-ocular distances.
A Mobile Automated Tomographic Gamma Scanning System - 13231
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.
2013-07-01
Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transportmore » container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)« less
First trimester size charts of embryonic brain structures.
Gijtenbeek, M; Bogers, H; Groenenberg, I A L; Exalto, N; Willemsen, S P; Steegers, E A P; Eilers, P H C; Steegers-Theunissen, R P M
2014-02-01
Can reliable size charts of human embryonic brain structures be created from three-dimensional ultrasound (3D-US) visualizations? Reliable size charts of human embryonic brain structures can be created from high-quality images. Previous studies on the visualization of both the cavities and the walls of the brain compartments were performed using 2D-US, 3D-US or invasive intrauterine sonography. However, the walls of the diencephalon, mesencephalon and telencephalon have not been measured non-invasively before. Last-decade improvements in transvaginal ultrasound techniques allow a better visualization and offer the tools to measure these human embryonic brain structures with precision. This study is embedded in a prospective periconceptional cohort study. A total of 141 pregnancies were included before the sixth week of gestation and were monitored until delivery to assess complications and adverse outcomes. For the analysis of embryonic growth, 596 3D-US scans encompassing the entire embryo were obtained from 106 singleton non-malformed live birth pregnancies between 7(+0) and 12(+6) weeks' gestational age (GA). Using 4D View (3D software) the measured embryonic brain structures comprised thickness of the diencephalon, mesencephalon and telencephalon, and the total diameter of the diencephalon and mesencephalon. Of 596 3D scans, 161 (27%) high-quality scans of 79 pregnancies were eligible for analysis. The reliability of all embryonic brain structure measurements, based on the intra-class correlation coefficients (ICCs) (all above 0.98), was excellent. Bland-Altman plots showed moderate agreement for measurements of the telencephalon, but for all other measurements the agreement was good. Size charts were constructed according to crown-rump length (CRL). The percentage of high-quality scans suitable for analysis of these brain structures was low (27%). The size charts of human embryonic brain structures can be used to study normal and abnormal development of brain development in future. Also, the effects of periconceptional maternal exposures, such as folic acid supplement use and smoking, on human embryonic brain development can be a topic of future research. This study was supported by the Department of Obstetrics and Gynaecology of the Erasmus University Medical Center. M.G. was supported by an additional grant from the Sophia Foundation for Medical Research (SSWO grant number 644). No competing interests are declared.
Witzel, Joachim G; Bogerts, Bernhard; Schiltz, Kolja
2016-09-01
This study aimed to assess whether brain pathology might be more abundant in forensic inpatients in a high-security setting than in non-criminal individuals. By using a previously used reliable approach, we explored the frequency and extent of brain pathology in a large group of institutionalized offenders who had not previously been considered to be suffering from structural brain damage and compare it to healthy, non-offending subjects. MRI and CT brain scans from 148 male inpatients of a high-security mental health institution (offense type: 51 sex, 80 violent, 9 arson, and 8 nonviolent) that were obtained due to headache, vertigo, or psychological complaints during imprisonment were assessed and compared to 52 non-criminal healthy controls. Brain scans were assessed qualitatively with respect to evidence of structural brain damage. Each case received a semiquantitative rating of "normal" (=0), "questionably abnormal" (=1), or "definitely abnormal" (=2) for the lateral ventricles, frontal/parietal cortex, and medial temporal structures bilaterally as well as third ventricle. Forensic inpatients displayed signs of brain damage to a significantly higher degree than healthy controls (p < 0.001). Even after adjustment for age, in the patients, being younger than the controls (p < 0.05), every offender type group displayed a higher proportion of subjects with brain regions categorized as definitely abnormal than the non-criminal controls. Within the forensic inpatients, offense type groups did not significantly differ in brain pathology. The astonishingly high prevalence of brain pathology in institutionalized inmates of a high-security mental health institution who previously had not been considered to be suffering from an organic brain syndrome raises questions on whether such neuroradiological assessment might be considered as a routine procedure in newly admitted patients. Furthermore, it highlights that organic changes, detectable under clinical routine conditions, may play a role in the development of legally relevant behavioral disturbances which might be underestimated.
Lai, M; Hodgson, T; Gawne-Cain, M; Webb, S; MacManus, D; McDonald, W I; Thompson, A J; Miller, D H
1996-01-01
Long TR and gadolinium enhanced spin echo brain MRI was performed weekly for three months in three patients with relapsing-remitting or secondary progressive multiple sclerosis. During the study, 38 new enhancing lesions were seen; 11 showed enhancement for less than four weeks, and two enhanced on only one scan. All 16 new lesions seen on long TR scans showed initial enhancement. When only every fourth (monthly) scan was analysed, a total of 33 new enhancing lesions were seen. Subject to confirmation in a larger cohort, the results suggest: (a) that blood brain barrier leakage is an invariable event in new lesion development in relapsing-remitting and secondary progressive multiple sclerosis; (b) the small increase in sensitivity of weekly scanning does not justify its use in preference to monthly scanning when monitoring treatments. Images PMID:8609517
Ghassibi, Mark P; Chien, Jason L; Patthanathamrongkasem, Thipnapa; Abumasmah, Ramiz K; Rosman, Michael S; Skaat, Alon; Tello, Celso; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul
2017-04-01
To compare varying circumpapillary optical coherence tomographic (OCT) scan diameters for glaucoma diagnosis. Prospective, cross-sectional, observational study. Circumpapillary retinal nerve fiber layer thickness (RNFLT) was measured using spectral-domain OCT in 1 randomly selected eye. Scans with diameters of 3.5, 4.1, and 4.7 mm were obtained, each with 7 parameters: mean global (G) RNFLT and mean RNFLT for the temporal-inferior (TI), nasal-inferior (NI), temporal-superior (TS), nasal-superior (NS), nasal (N), and temporal (T) sectors. Areas under the receiver operating characteristic curve (AUCs) were calculated. Mean age was 55±18 years in 68 healthy eyes and 59±15 years in 95 glaucomatous eyes (P=0.12). Visual field mean deviation was -7.55±6.61 dB in glaucomatous eyes. In all 3 circle scans, mean TI RNFLT had the greatest AUC (0.974 to 0.983), followed by mean G RNFLT (0.949 to 0.956). The AUC of mean TI RNFLT in the 4.1-mm scan (0.983) was greater than the AUCs of mean TI RNFLTs in the 4.7- (0.978; P=0.128) and 3.5-mm (0.974; P=0.049) scans. The AUC of mean TI RNFLT in the 4.1-mm scan (0.983) was greater than the AUCs of mean G RNFLTs in the 3.5- (0.954; P=0.011), 4.1- (0.956; P=0.016), and 4.7-mm (0.949; P=0.011) scans. In 2 eyes with large parapapillary atrophy, RNFL segmentation error was noted only in the 3.5-mm scan in the area of parapapillary atrophy. Further investigations to find the spectral-domain OCT circle scan diameter with the best diagnostic capability and the least artifacts are warranted, especially focusing on larger-than-conventional circle scans.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, J; Park, C; Kauweloa, K
2015-06-15
Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-raymore » projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various on-line clinical applications.« less
NASA Astrophysics Data System (ADS)
Thompson, Joseph R.; M oore, Robert J.; Hinshaw, David B.; Hasso, Anton N.
1982-12-01
Density resolution the accuracy of CT numbers) is generally recognized by radiologists w'ao interpret Children's, CT to be very poor. A CT scanning phantom was made. in order to document the brain attenuation inaccuracies which do occur and also to derive normal brain attenuation values for varying sized heads, given. the skull diameters and thicknesses. In scanning' this phantom, other factors, some of equal importance, to small head size, were found to affect the Hounsfield numbers of brain. The phantom was scanned in order to determine the magnitude of these specific factors, using the GE 8800 model scanner. After head size (412 to 25, H), the variables of the head support (up to 15 H) and centering within the field of view (6-23 H) were of similar importance, for small heads. Kilovoltage, software, and machine drift were less, important, although only kVp settings, of 105 and 120 were employed. Manufacturers may improve CT number accuracy if they recognize the relative, magnitude of the various factors which alter measured attenuation.
Regional CBF in chronic stable TBI treated with hyperbaric oxygen.
Barrett, K F; Masel, B; Patterson, J; Scheibel, R S; Corson, K P; Mader, J T
2004-01-01
To investigate whether Hyperbaric Oxygen Therapy (HBO2) could improve neurologic deficits and regional cerebral blood flow (rCBF) in chronic traumatic brain injuries (TBI), the authors employed a nonrandomized control pilot trial. Five subjects, at least three years post head injury, received HBO2. Five head injured controls (HIC) were matched for age, sex, and type of injury. Five healthy subjects served as normal controls. Sixty-eight normal volunteers comprised a reference data bank against which to compare SPECT brain scans. HBO2 subjects received 120 HBO2 in blocks of 80 and 40 treatments with an interval five-month break. Normal controls underwent a single SPECT brain scan, HBO2, and repeat SPECT battery. TBI subjects were evaluated by neurologic, neuropsychometric, exercise testing, and pre and post study MRIs, or CT scans if MRI was contraindicated. Statistical Parametric Mapping was applied to SPECT scans for rCBF analysis. There were no significant objective changes in neurologic, neuropsychometric, exercise testing, MRIs, or rCBF. In this small pilot study, HBO2 did not effect clinical or regional cerebral blood flow improvement in TBI subjects.
Gülşen, İsmail; Ak, Hakan; Karadaş, Sevdegül; Demır, İsmail; Bulut, Mehmet Deniz; Yaycioğlu, Soner
2014-01-01
Objective. To investigate the indications to receive brain computed tomography (CT) scan and to define the pathological findings in children younger than three years of age with minor head trauma in emergency departments. Methods. In this study, hospital case notes of 1350 children attending the emergency department of Bitlis State Hospital between January 2011 and June 2013 were retrospectively reviewed. 508 children under 3 years of age with minor head trauma were included in this study. We also asked 37 physicians about the indications for requiring CT in these children. Results. This study included 508 children, 233 (45,9%) of whom were female and 275 were male. In 476 (93,7%) children, the brain CT was completely normal. 89,2% of physicians asked in the emergency department during that time interval reported that they requested CT scan to protect themselves against malpractice litigation. Conclusion. In infants and children with minor head trauma, most CT scans were unnecessary and the fear of malpractice litigation of physicians was the most common reason for requesting a CT. PMID:24724031
Gestational Age and Neonatal Brain Microstructure in Term Born Infants: A Birth Cohort Study
Broekman, Birit F. P.; Wang, Changqing; Li, Yue; Rifkin-Graboi, Anne; Saw, Seang Mei; Chong, Yap-Seng; Kwek, Kenneth; Gluckman, Peter D.; Fortier, Marielle V.; Meaney, Michael J.; Qiu, Anqi
2014-01-01
Objective Understanding healthy brain development in utero is crucial in order to detect abnormal developmental trajectories due to developmental disorders. However, in most studies neuroimaging was done after a significant postnatal period, and in those studies that performed neuroimaging on fetuses, the quality of data has been affected due to complications of scanning during pregnancy. To understand healthy brain development between 37–41 weeks of gestational age, our study assessed the in utero growth of the brain in healthy term born babies with DTI scanning soon after birth. Methods A cohort of 93 infants recruited from maternity hospitals in Singapore underwent diffusion tensor imaging between 5 to 17 days after birth. We did a cross-sectional examination of white matter microstructure of the brain among healthy term infants as a function of gestational age via voxel-based analysis on fractional anisotropy. Results Greater gestational age at birth in term infants was associated with larger fractional anisotropy values in early developing brain regions, when corrected for age at scan. Specifically, it was associated with a cluster located at the corpus callosum (corrected p<0.001), as well as another cluster spanning areas of the anterior corona radiata, anterior limb of internal capsule, and external capsule (corrected p<0.001). Conclusions Our findings show variation in brain maturation associated with gestational age amongst ‘term’ infants, with increased brain maturation when born with a relatively higher gestational age in comparison to those infants born with a relatively younger gestational age. Future studies should explore if these differences in brain maturation between 37 and 41 weeks of gestational age will persist over time due to development outside the womb. PMID:25535959
Jahanshad, Neda; Rajagopalan, Priya; Hua, Xue; Hibar, Derrek P; Nir, Talia M; Toga, Arthur W; Jack, Clifford R; Saykin, Andrew J; Green, Robert C; Weiner, Michael W; Medland, Sarah E; Montgomery, Grant W; Hansell, Narelle K; McMahon, Katie L; de Zubicaray, Greig I; Martin, Nicholas G; Wright, Margaret J; Thompson, Paul M
2013-03-19
Aberrant connectivity is implicated in many neurological and psychiatric disorders, including Alzheimer's disease and schizophrenia. However, other than a few disease-associated candidate genes, we know little about the degree to which genetics play a role in the brain networks; we know even less about specific genes that influence brain connections. Twin and family-based studies can generate estimates of overall genetic influences on a trait, but genome-wide association scans (GWASs) can screen the genome for specific variants influencing the brain or risk for disease. To identify the heritability of various brain connections, we scanned healthy young adult twins with high-field, high-angular resolution diffusion MRI. We adapted GWASs to screen the brain's connectivity pattern, allowing us to discover genetic variants that affect the human brain's wiring. The association of connectivity with the SPON1 variant at rs2618516 on chromosome 11 (11p15.2) reached connectome-wide, genome-wide significance after stringent statistical corrections were enforced, and it was replicated in an independent subsample. rs2618516 was shown to affect brain structure in an elderly population with varying degrees of dementia. Older people who carried the connectivity variant had significantly milder clinical dementia scores and lower risk of Alzheimer's disease. As a posthoc analysis, we conducted GWASs on several organizational and topological network measures derived from the matrices to discover variants in and around genes associated with autism (MACROD2), development (NEDD4), and mental retardation (UBE2A) significantly associated with connectivity. Connectome-wide, genome-wide screening offers substantial promise to discover genes affecting brain connectivity and risk for brain diseases.
1992-05-25
by a by the distinctions between short-term and long-term sensory event. As evidence they shom that %khen the ISI memory ’. episodic , semantic and...Patterson. J.V. and Starr. A. I 19S9a) ams .1 function of variations in semantic citaceori,’itions. In: D. Brain potentials in a memory scanning task. 1...number) FIELD GROUP SUB-GROUP L ocalization of cognitive processes; alpha-band suppression; memory scanning for tones; silent speech; visual image