Sample records for top quality cava

  1. The Isolated Perfused Rat Liver and its use in the Study of Chemical Kinetics: Quality and Performance Parameters

    DTIC Science & Technology

    1999-04-01

    atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava

  2. Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines.

    PubMed

    Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel

    2016-10-27

    Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na⁺, K⁺, Ca 2+ , Cl - , and CO₃ 2- , one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.

  3. Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines

    PubMed Central

    Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel

    2016-01-01

    Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions. PMID:27801796

  4. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    PubMed

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  5. Validation of a computerized technique for automatically tracking and measuring the inferior vena cava in ultrasound imagery.

    PubMed

    Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew

    2014-01-01

    Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.

  6. Inferior Vena Cava Filter Placement and Removal

    MedlinePlus

    ... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...

  7. Inferior Vena Cava Filter from Left-Sided Superior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nair, Sujit, E-mail: drsnnair@hotmail.com; Ettles, Duncan; Robinson, Graham

    We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.

  8. Use of ultrasound in altitude decompression modeling

    NASA Technical Reports Server (NTRS)

    Olson, Robert M.; Pilmanis, Andrew A.

    1993-01-01

    A model that predicts the probability of developing decompression sickness (DCS) with various denitrogenation schedules is being developed by the Armstrong Laboratory, using human data from previous exposures. It was noted that refinements are needed to improve the accuracy and scope of the model. A commercially developed ultrasonic echo imaging system is being used in this model development. Using this technique, bubbles images from a subject at altitude can be seen in the gall bladder, hepatic veins, vena cava, and chambers of the heart. As judged by their motion and appearance in the vena cava, venous bubbles near the heart range in size from 30 to 300 M. The larger bubbles skim along the top, whereas the smaller ones appear as faint images near the bottom of the vessel. Images from growing bubbles in a model altitude chamber indicate that they grow rapidly, going from 20 to 100 M in 3 sec near 30,000 ft altitude. Information such as this is valuable in verifying those aspects of the DCS model dealing with bubble size, their growth rate, and their site of origin.

  9. The use of retrievable inferior vena cava filters in pregnancy: Another successful case report, but are we actually making a difference?

    PubMed

    Du Plessis, Lodewyk E; Mol, Ben W; Svigos, John M

    2016-09-01

    Pregnant women with venous thromboembolism are traditionally managed with anticoagulation, but inferior vena cava filters are an alternative. We balanced risks and benefits of an inferior vena cava filter in a decision analysis. We constructed a decision model to compare in pregnant women with VTE the outcome of (1) inferior vena cava filter and anticoagulant treatment versus (2) anticoagulant treatment only. Assuming a 63% risk reduction from an inferior vena cava filter (baseline mortality rate of venous thromboembolism of 0.5%), 318 women would need to be treated with inferior vena cava filters to prevent one venous thromboembolism related maternal death. Sensitivity analyses indicated that at a mortality rate of 0.5% the risk reduction from inferior vena cava filters needed to be 80%, while at a mortality rate of 2% a risk reduction of 20% would justify inferior vena cava filters. In view of their potential morbidity, inferior vena cava filters should be restricted to pregnant woman at strongly increased risk of recurrent venous thromboembolism.

  10. Inferior vena cava filters.

    PubMed

    Duffett, L; Carrier, M

    2017-01-01

    Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.

  11. Combat Surgery: Medical Decision Trees for Treatment of Naval Combat Casualties

    DTIC Science & Technology

    1991-02-01

    inferior vena cava ? NO Is there a hole or tear of left atrium and/or pulmonary veins? NO l ** HEART INJURY ASSESSMENT MODULE T027 2...from holes in either superior or inferior vena cava ? YES NO See Pericardial Vena Cava Injury Module See Bleeding Into Pericardium Module T018...MODULE T018 1/1 Is blood coming from area of superior vena cava ? YES NO See Superior Vena Cava Wound

  12. Treatment of Superior Vena Cava (SVC) Syndrome and Inferior Vena Cava (IVC) Thrombosis in a Patient with Colorectal Cancer: Combination of SVC Stenting and IVC Filter Placement to Palliate Symptoms and Pave the Way for Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauter, Alexander; Triller, Juergen; Schmidt, Felix

    Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less

  13. Heart Transplant in Patient With Isolated Left Superior Vena Cava by Atrial Appendage Rotation.

    PubMed

    Reyes, Karl M; Gupta, Dipankar; Fricker, Frederick Jay; Cooke, Susan; Bleiweis, Mark S

    2018-06-01

    Orthotopic heart transplantation in patients with an isolated persistent left superior vena cava is extremely rare, and the anastomotic connection between a right-sided donor superior vena cava and left-sided recipient superior vena cava can be challenging to perform. We present a novel technique used in an infant female, using the left atrial appendage to extend the superior vena cava anastomosis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Endovascular management of inferior vena cava filter thrombotic occlusion.

    PubMed

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  15. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    PubMed

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  16. Complications of inferior vena cava filters.

    PubMed

    Sella, David M; Oldenburg, W Andrew

    2013-03-01

    With the introduction of retrievable inferior vena cava filters, the number being placed for protection from pulmonary embolism is steadily increasing. Despite this increased usage, the true incidence of complications associated with inferior vena cava filters is unknown. This article reviews the known complications associated with these filters and suggests recommendations and techniques for inferior vena cava filter removal. Copyright © 2013. Published by Elsevier Inc.

  17. Congenital anomalies of the inferior vena cava revealed on CT in patients with deep vein thrombosis.

    PubMed

    Gayer, G; Luboshitz, J; Hertz, M; Zissin, R; Thaler, M; Lubetsky, A; Bass, A; Korat, A; Apter, S

    2003-03-01

    We describe a possible relationship between inferior vena cava anomalies and extensive thrombosis of the inferior vena cava and the iliac and femoral veins. An anomaly of the inferior vena cava should be considered in young patients who present with deep vein thrombosis of the femoral and iliac veins. Coagulation abnormalities, frequently found in these patients, may be a contributory factor.

  18. Reconstruction of a total avulsion of the hepatic veins and the suprahepatic inferior vena cava secondary to blunt thoracoabdominal trauma.

    PubMed

    Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten

    2011-02-01

    Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.

  19. The fenestrated Kawashima operation for single ventricle with interrupted inferior vena cava.

    PubMed

    Hannan, Robert L; Rossi, Anthony F; Nykanen, David G; Lopez, Leo; Alonso, Francisco; White, Jeffrey A; Burke, Redmond P

    2003-01-01

    An 8-month-old boy with double outlet right ventricle with hypoplastic left ventricle, heterotaxy, left atrial isomerism, bilateral superior vena cavae without bridging vein, and interruption of the inferior vena cava with azygous continuation to the left superior cava underwent a bilateral bidirectional cavopulmonary anastomosis. A calibrated 3-mm connection between the right pulmonary artery and the common atrium was constructed with the proximal right superior vena cava to allow right to left shunting, analogous to a fenestration in a Fontan operation. We hypothesize that in small young patients undergoing the Kawashima operation a fenestration may improve postoperative hemodynamics.

  20. Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.

    PubMed

    Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo

    2006-07-01

    Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.

  1. Pressure-Guided Positioning of Bicaval Dual-Lumen Catheters for Venovenous Extracorporeal Gas Exchange

    DTIC Science & Technology

    2013-01-01

    inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory

  2. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    PubMed

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  3. Urologic Oncologic SurveyRobotic level III inferior vena cava tumor thrombectomy: Initial series. Gill IS, Metcalfe C, Abreu A, Duddalwar V, Chopra S, Cunningham M, Thangathurai D, Ukimura O, Satkunasivam R, Hung A, Papalia R, Aron M, Desai M, Gallucci M. J Urol. 2015 Oct;194(4):929-938. [Epub 2015 Apr 6]. doi: 10.1016/j.juro.2015.03.119.

    PubMed

    Meng, Max

    2017-05-01

    Level III inferior vena cava tumor thrombectomy for renal cancer is one of the most challenging open urologic surgeries. We present the initial series of completely intracorporeal robotic level III inferior vena cava tumor thrombectomy. Nine patients underwent robotic level III inferior vena cava thrombectomy and 7 patients underwent level II thrombectomy. The entire operation (high intrahepatic inferior vena cava control, caval exclusion, tumor thrombectomy, inferior vena cava repair, radical nephrectomy, and retroperitoneal lymphadenectomy) was performed exclusively robotically. To minimize the chances of intraoperative inferior vena cava thrombus embolization, an "inferior vena cava-first, kidney-last" robotic technique was developed. Data were accrued prospectively. All 16 robotic procedures were successful, without open conversion or mortality. For level III cases (9), median primary kidney (right 6, left 3) cancer size was 8.5cm (range: 5.3-10.8) and inferior vena cava thrombus length was 5.7cm (range: 4-7). Median operative time was 4.9 hours (range: 4.5-6.3), estimated blood loss was 375ml (range: 200-7,000), and hospital stay was 4.5 days. All surgical margins were negative. There were no intraoperative complications and 1 postoperative complication (Clavien 3b). At a median 7 months of follow-up (range: 1-18) all patients are alive. Compared to level II thrombi the level III cohort trended toward greater inferior vena cava thrombus length (3.3 vs 5.7cm), operative time (4.5 vs 4.9h) and blood loss (290 vs 375ml). With appropriate patient selection, surgical planning and robotic experience, completely intracorporeal robotic level III inferior vena cava thrombectomy is feasible and can be performed efficiently. Larger experience, longer follow-up and comparison with open surgery are needed to confirm these initial outcomes. Copyright © 2017. Published by Elsevier Inc.

  4. Two cases of left superior vena cava draining directly to a left atrium with a normal coronary sinus.

    PubMed Central

    Wiles, H B

    1991-01-01

    The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125

  5. Ecklonia cava promotes hair growth.

    PubMed

    Bak, S S; Ahn, B N; Kim, J A; Shin, S H; Kim, J C; Kim, M K; Sung, Y K; Kim, S K

    2013-12-01

    Previous studies have reported the protective effects on skin elasticity of the edible marine seaweed Ecklonia cava, which acts through regulation of both antioxidative and anti-inflammatory responses. We evaluated the effect of E. cava and one of its components, dioxinodehydroeckol, on hair-shaft growth in cultured human hair follicles and on hair growth in mice. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to check cell viability of human dermal papilla cells (DPCs) and outer root sheath (ORS) cells after treatment with E. cava and its metabolite, dioxinodehydroeckol. Hair-shaft growth was measured using the in vitro hair-follicle organ-culture system, in the presence or absence of E. cava and dioxinodehydroeckol. Anagen induction activity was examined by topical application of E. cava to the dorsal skin of C57BL/6 mice. Insulin-like growth factor (IGF)-1 expression was measured by reverse transcriptase PCR and ELISA. The proliferation activity was found to be highest for the ethyl acetate-soluble fraction of E. cava (EAFE) in DPCs and in ORS cells. Treatment with EAFE resulted in elongation of the hair shaft in cultured human hair follicles, and promoted transition of the hair cycle from the telogen to the anagen phase in the dorsal skin of C57BL/6 mice. In addition, EAFE induced an increase in IGF-1 expression in DPCs. Dioxinodehydroeckol, a component of E. cava, induced elongation of the hair shaft, an increase in proliferation of DPCs and ORS cells, and an increase in expression of IGF-1 in DPCs. These results suggest that E. cava containing dioxinodehydroeckol promotes hair growth through stimulation of DPCs and ORS cells. © 2013 British Association of Dermatologists.

  6. Left Superior Vena Cava Draining Into Left Atrium in Tetralogy of Fallot-Four Cases of a Rare Association.

    PubMed

    Ramman, Tarun Raina; Dutta, Nilanjan; Chowdhuri, Kuntal Roy; Agrawal, Sunny; Girotra, Sumir; Azad, Sushil; Radhakrishnan, Sitaraman; Iyer, Parvathi Unninayar; Iyer, Krishna Subramony

    2018-01-01

    Persistent left superior vena cava is a common congenital anomaly of the thoracic venous system. Left superior vena cava draining into left atrium is a malformation of sinus venosus and caval system. The anomaly may be a cause of unexplained hypoxia even in adults. It may give rise to various diagnostic and technical challenges during cardiac catheterization and open-heart surgery. It is often detected serendipitously during diagnostic workup. Isolated left superior vena cava opening into left atrium is very commonly associated with other congenital heart defects. But tetralogy of Fallot is very rarely associated with persistent left superior vena cava which drains into left atrium. We report four such cases who underwent surgical correction successfully.

  7. Cross-sectional echocardiographic diagnosis of azygos continuation of the inferior vena cava.

    PubMed

    Huhta, J C; Smallhorn, J F; Macartney, F J

    1984-01-01

    Azygos continuation of the inferior vena cava has importance for both the invasive diagnosis of congenital heart disease by catheterization and for surgical treatment. Cross-sectional echocardiography was used to examine 1,000 patients (1 day to 16 years, mean 3.3 years) who also had angiographic or surgical confirmation. Twenty-eight patients (3%) had azygos continuation (left 13, right 14, bilateral 1) and, in 26 patients, the hepatic portion of the inferior vena cava was absent. Azygos continuation was prospectively detected in all and was directly visualized in subcostal scans as a venous structure posterior to the aorta coursing behind the heart and not entering the inferior aspect of either atrium in 26/28 (93%). Azygos connection to the ipsilateral superior vena cava or atrium was correctly predicted in all. The inferior vena cava was visualized in all patients without azygos continuation, except one neonate with omphalocele. We conclude that cross-sectional echocardiography can accurately detect azygos continuation of the inferior vena cava and predict its side and connection.

  8. Cross-sectional echocardiographic diagnosis of systemic venous return.

    PubMed Central

    Huhta, J C; Smallhorn, J F; Macartney, F J; Anderson, R H; de Leval, M

    1982-01-01

    To determine the sensitivity and specificity of cross-sectional echocardiography in diagnosing anomalous systemic venous return we used the technique in 800 consecutive children with congenital heart disease and whom the diagnosis was ultimately confirmed by angiography. Cross-sectional echocardiography was performed without prior knowledge of the diagnosis in all but 11 patients, who were recalled because of a known abnormality of atrial situs. The sensitivity of cross-sectional echocardiographic detection of various structures was as follows: right superior vena cava 792/792 (100%); left superior vena cava 46/48 (96%); bilateral superior vena cava 38/40 (95%); bridging innominate vein with bilateral superior vena cava 13/18 (72%); connection of superior caval segment to heart (coronary sinus or either atrium) (100%); absence of suprarenal inferior vena cava 23/23 (100%); azygos continuation of the inferior vena cava 31/33 (91%); downstream connection of azygos continuation, once seen, 21/21 (100%); partial anomalous hepatic venous connection (one hepatic vein not connected to the inferior vena cava) 1/1 (100%); total anomalous hepatic venous connection (invariably associated with left isomerism) 23/23 (100%). The specificity of each above diagnoses was 100% except in one infant with exomphalos in whom absence of the suprarenal inferior vena cava was incorrectly diagnosed. Thus cross-sectional echocardiography is an extremely specific and highly sensitive method of recognizing anomalous systemic venous return. It is therefore of great value of planning both cardiac catheterisation and cannulation for open heart surgery. Images PMID:6751361

  9. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  10. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  11. Successful Percutaneous Retrieval of an Inferior Vena Cava Filter Migrating to the Right Ventricle in a Bariatric Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veerapong, Jula; Wahlgren, Carl Magnus, E-mail: carl.wahlgren@karolinska.s; Jolly, Neeraj

    The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.

  12. Anomalies of the systemic venous return: a review.

    PubMed

    Mazzucco, A; Bortolotti, U; Stellin, G; Gallucci, V

    1990-06-01

    Congenital anomalies of the systemic venous connection to the heart represent a rather wide and heterogeneous group of malformations, whose physiological consequences may vary from nil to the most severe form of systemic arterial desaturation. The malformations may be summarized as follows: (1) Left superior vena cava connected to the coronary sinus, interrupted inferior vena cava and absent right superior vena cava that do not indicate surgical repair 'per se', but require some technical attention during open heart surgery performed for other anomalies; (2) Left superior vena cava connected to the left atrium, due to incorporation of the coronary sinus into the left atrial cavity, resulting in a right-to-left-shunt; (3) Right superior vena cava or inferior vena cava draining into the left atrium, both are extremely rare and require treatment for the ensuing right-to-left shunt; (4) Total anomalous systemic venous connection to the left atrium, usually combined with atrial isomerism and other very complex heart malformations; (5) Cor triatriatum dexter, which has been frequently diagnosed as an anomalous venous connection for its similar hemodynamic consequences. Such anomalies are reviewed with particular respect to their surgical implications.

  13. Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.

    PubMed

    Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel

    2015-12-01

    We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.

  14. Unusual presentation of total anomalous systemic venous connection.

    PubMed

    Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Pradhan, Priya M; Agarwal, Ravi

    2017-07-01

    A 9-year-old girl who presented with dyspnea on exertion was diagnosed with total anomalous systemic venous connection to the left atrium (both venae cavae), no left superior vena cava, and a moderate-sized atrial septal defect with severe pulmonary arterial hypertension and ectopic atrial rhythm. She underwent septation of the common atrium using autologous pericardium, thereby rerouting the superior vena cava, inferior vena cava, and coronary sinus to the right atrium. Her postoperative course was uneventful. This case is reported for its rarity of presentation with severe pulmonary arterial hypertension and ectopic atrial rhythm.

  15. Vena cava filters and thrombolytic therapeutic monitoring based on functional near-infrared spectroscopy for deep vein thrombosis

    NASA Astrophysics Data System (ADS)

    Pan, Boan; Liu, Weichao; Fang, Xiang; Zhao, Ke; Li, Ting

    2018-02-01

    Deep vein thrombosis (DVT), happening in inpatients usually and especially with the postoperative population, is a serious disease characterized by an increased incidence. The venography is the golden standard to diagnose DVT. However, it involves invasive contrast agent injection and give patients physical and mental pressure. Functional nearinfrared spectroscopy (fNIRS) has been reported recently to diagnose DVT. Thrombolytic therapy activates the dissolution system with an exogenous activator that dissolves coronary thrombosis. The vena cava filter is a medical filter used for the treatment of thrombosis and the prevention of pulmonary embolism. Here we attempt to use portable NIRS for the DVT monitoring in the whole process of vena cava filter implantation and thrombolytic treatment, and contrast the patients of untreated, vena cava filter implantation and thrombolytic treatment. 19 DVT patients and 12 normal subjects were recruited. Thereinto, 7 patients have taken vena cava filter implantation, and 6 patients have taken the thrombolytic treatment. It was found that deoxyhemoglobins (Δ[Hb]) fluctuates and even increases in DVT. After vena cava filter implantation, Δ[Hb] increases first, then decreases. However, it emerges the rising trend and converge to the curves of normal subjects in thrombolytic treatment. The oxyhemoglobins (Δ[HbO2]) emerges opposite trend in most paradigms. The findings reveal the potential of fNIRS for monitoring DVT and therapeutic effect evaluation of thrombolysis and vena cava filters.

  16. Course of the inferior vena cava on lateral films exposed in different positions.

    PubMed

    Lien, H H; Bakke, S J

    1981-01-01

    The distance from the posterior border of the inferior vena cava to the anterior vertebral margin was measured in 100 presumably normal patients in the supine position. Seventeen of these were also examined in the right and left lateral positions and the changes in course of the vena cava compared with the supine position.

  17. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  18. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less

  19. A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions

    PubMed Central

    Montgomery, Jennifer P.; Kaufman, John A.

    2016-01-01

    Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration. PMID:27247475

  20. A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions.

    PubMed

    Montgomery, Jennifer P; Kaufman, John A

    2016-06-01

    Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration.

  1. The short-term efficacy of vena cava filters for the prevention of pulmonary embolism in patients with venous thromboembolism receiving anticoagulation: Meta-analysis of randomized controlled trials.

    PubMed

    Jiang, Jun; Jiao, Yuanyong; Zhang, Xiwei

    2017-10-01

    Objectives To perform a meta-analysis of randomized controlled trials assessing the effectiveness of inferior vena cava filters in patients with deep vein thrombosis for preventing pulmonary embolism. Method Relevant randomized controlled trials of inferior vena cava filters for the prevention of pulmonary embolism were identified by searching electronic databases updated in February 2016. Relative risks of recurrent pulmonary embolism, recurrent deep vein thrombosis, and mortality at three months were analyzed. Results Three published randomized controlled trials were included involving a total of 863 deep vein thrombosis patients. No significant differences were detected with inferior vena cava filters placement with regard to the incidence of recurrent pulmonary embolism or fatal pulmonary embolism. There were also no significant differences in the incidence of recurrent deep vein thrombosis or mortality with inferior vena cava filters placement at three months. Conclusions Inferior vena cava filter in addition to anticoagulation was not associated with a reduction in the incidence of recurrent pulmonary embolism as compared with anticoagulation alone in patients with deep vein thrombosis in the short term.

  2. Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.

    PubMed

    Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F

    2003-11-01

    To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.

  3. Ecklonia cava Extract and Dieckol Attenuate Cellular Lipid Peroxidation in Keratinocytes Exposed to PM10.

    PubMed

    Lee, Jeong-Won; Seok, Jin Kyung; Boo, Yong Chool

    2018-01-01

    Airborne particulate matter can cause oxidative stress, inflammation, and premature skin aging. Marine plants such as Ecklonia cava Kjellman contain high amounts of polyphenolic antioxidants. The purpose of this study was to examine the antioxidative effects of E. cava extract in cultured keratinocytes exposed to airborne particulate matter with a diameter of <10  μ m (PM10). After the exposure of cultured HaCaT keratinocytes to PM10 in the absence and presence of E. cava extract and its constituents, cell viability and cellular lipid peroxidation were assessed. The effects of eckol and dieckol on cellular lipid peroxidation and cytokine expression were examined in human epidermal keratinocytes exposed to PM10. The total phenolic content of E. cava extract was the highest among the 50 marine plant extracts examined. The exposure of HaCaT cells to PM10 decreased cell viability and increased lipid peroxidation. The PM10-induced cellular lipid peroxidation was attenuated by E. cava extract and its ethyl acetate fraction. Dieckol more effectively attenuated cellular lipid peroxidation than eckol in both HaCaT cells and human epidermal keratinocytes. Dieckol and eckol attenuated the expression of inflammatory cytokines such as tumor necrosis factor- (TNF-) α , interleukin- (IL-) 1 β , IL-6, and IL-8 in human epidermal keratinocytes stimulated with PM10. This study suggested that the polyphenolic constituents of E. cava , such as dieckol, attenuated the oxidative and inflammatory reactions in skin cells exposed to airborne particulate matter.

  4. Indications, complications and outcomes of inferior vena cava filters: A retrospective study.

    PubMed

    Wassef, Andrew; Lim, Wendy; Wu, Cynthia

    2017-05-01

    Inferior vena cava filters are used to prevent embolization of a lower extremity deep vein thrombosis when the risk of pulmonary embolism is thought to be high. However, evidence is lacking for their benefit and guidelines differ on the recommended indications for filter insertion. The study aim was to determine the reasons for inferior vena cava filter placement and subsequent complication rate. A retrospective cohort of patients receiving inferior vena cava filters in Edmonton, Alberta, Canada from 2007 to 2011. Main outcome was the indication of inferior vena cava filter insertion. Other measures include baseline demographic and medical history of patients, clinical outcomes and filter retrieval rates. 464 patients received inferior vena cava filters. An acute deep vein thrombosis with a contraindication to anticoagulation was the indication for 206 (44.4%) filter insertions. No contraindication to anticoagulation could be identified in 20.7% of filter placements. 30.6% were placed in those with active cancer, in which mortality was significantly higher. Only 38.9% of retrievable filters were successfully retrieved. Inferior vena cava filters were placed frequently in patients with weak or no guideline-supported indications for filter placement and in up to 20% of patients with no contraindication to anticoagulation. The high rates of cancer and the high mortality rate of the cohort raise the possibility that some filters are placed inappropriately in end of life settings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. 1995 Toxic Hazards Research Unit Annual Report.

    DTIC Science & Technology

    1996-07-01

    cabinet, the bile duct is cannulated using PE-10 tubing, the portal vein and inferior vena cava (above the diaphragm) are both cannulated with 16...homogenate in saline. Rats used to determine partition coefficients were euthanatized with C02. Blood was collected from the posterior vena cava ...sampled for histopathologic examination. Blood was sampled via the vena cava for clinical chemistry evaluations and whole livers were weighed at

  6. Non-Invasive Methods of Cardiovascular Exploration in Aerospace Medicine.

    DTIC Science & Technology

    1983-12-01

    inferior vena cava Aorta right atrium filling chamber of right ventricle. Trunk of pulmonary art cry Posterior border: almost vertical AP lower arch left ... left ventricle. Inferior Vena cava infundihbulum L Upper border aortic arch Lower border superimposed borders of the RV LV right and left ventricles...iliac aneurisms is possible. isotopic phlebography is useful in the investigation of the permeability of the inferior vena cava

  7. In Vitro Evaluation of a Rheolytic Thrombectomy System for Clot Removal from Five Different Temporary Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buecker, Arno; Neuerburg, Joerg; Schmitz-Rode, Thomas

    1997-11-15

    Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombusmore » were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.« less

  8. Isolated Right Superior Vena Cava Drainage into the Left Atrium Diagnosed Noninvasively in the Peripartum Period

    PubMed Central

    Baggett, Charles; Skeen, Shawn J.; Gantt, D. Scott; Trotter, Bradley R.; Birkemeier, Krista L.

    2009-01-01

    Isolated right superior vena cava drainage into the left atrium is an extremely rare cardiac anomaly, especially in the absence of other cardiac abnormalities. Only 28 of 5,127 reported consecutive congenital cardiac cases involved superior vena cava drainage into the left atrium, and all were associated with other cardiac anomalies. Of 19 reported cases of right superior vena cava drainage into the left atrium, most patients have been children who were experiencing mild hypoxemia and cyanosis. Herein, we describe the case of a 34-year-old woman who presented with asymptomatic hypoxemia in the peripartum period. She was diagnosed to have isolated drainage of the right superior vena cava into the left atrium. To the best of our knowledge, this is the 1st reported instance of such diagnosis by use of noninvasive imaging only, without cardiac catheterization. We also review the medical literature that pertains to our patient's anomaly. PMID:20069093

  9. Exploiting biological activities of brown seaweed Ecklonia cava for potential industrial applications: a review.

    PubMed

    Wijesinghe, W A J P; Jeon, You-Jin

    2012-03-01

    Seaweeds are rich in vitamins, minerals, dietary fibres, proteins, polysaccharides and various functional polyphenols. Many researchers have focused on brown algae as a potential source of bioactive materials in the past few decades. Ecklonia cava is a brown seaweed that is abundant in the subtidal regions of Jeju Island in the Republic of Korea. This seaweed attracted extensive interest due to its multiple biological activities. E. cava has been identified as a potential producer of wide spectrum of natural substances such as carotenoids, fucoidans and phlorotannins showing different biological activities in vital industrial applications including pharmaceutical, nutraceutical, cosmeceutical and functional food. This review focuses on biological activities of the brown seaweed E. cava based on latest research results, including antioxidant, anticoagulative, antimicrobial, antihuman immunodeficiency virus, anti-inflammatory, immunomodulatory, antimutagenic, antitumour and anticancer effects. The facts summarized here may provide novel insights into the functions of E. cava and its derivatives and potentially enable their use as functional ingredients in potential industrial applications.

  10. Role of cardiac output and the autonomic nervous system in the antinatriuretic response to acute constriction of the thoracic superior vena cava.

    NASA Technical Reports Server (NTRS)

    Schrier, R. W.; Humphreys, M. H.; Ufferman, R. C.

    1971-01-01

    Study of the differential characteristics of hepatic congestion and decreased cardiac output in terms of potential afferent stimuli in the antinatriuretic effect of acute thoracic inferior vena cava (TIVC) constriction. An attempt is made to see if the autonomic nervous system is involved in the antinatriuretic effect of acute TIVC or thoracic superior vena cava constriction.

  11. Large left circumflex coronary artery with a fistula to superior vena cava: Diagnosis by echocardiography.

    PubMed

    Liu, Yunqi; Liu, Yanqiu; Xiong, Mai; Li, Hanzhao; Liu, Donghong; Zhang, Xi

    2017-04-01

    The left circumflex coronary artery associated with a fistula to superior vena cava is a rare entity. We describe a 7-year-old girl who presented with a cardiac murmur and was diagnosed with a coronary artery fistula between the left circumflex artery and superior vena cava by echocardiography. The surgical occlusion of the fistula was successful. © 2017, Wiley Periodicals, Inc.

  12. Surgical management of the left superior vena cava draining into the left atrium: a novel off-pump technique using the left atrial appendage

    PubMed Central

    Boutayeb, Alaae; Marmade, Lahcen; Bensouda, Adil; Moughil, Said

    2012-01-01

    The left superior vena cava is the most common congenital venous anomaly in the chest; however, its drainage into the left atrium is exceptional. The aim of the paper is to describe our novel technique to connect the left superior vena cava to the right cavities using the left atrial appendage, without cardiopulmonary bypass. PMID:22802356

  13. Annual Progress Report Fiscal Year 1989

    DTIC Science & Technology

    1989-09-30

    thopaedics, Las Vegas, NV, February, 1989 clusion of the common iliac veins and inferior vena cava H following vaginal hysterectomy. A case report...The aorta and inferior vena cava will be transected and cannulated. Using techniques prescribed in the Microill product literature the aorta and both...via the inferior vena cava . At that point the animals will be refrigerated to allow overnight curing of the Microfil. As each animal has had only one

  14. The Use of Hypertonic Solutions to Resuscitate Animals from Hypovolemic Shock.

    DTIC Science & Technology

    1986-03-18

    halothane/nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed...and on skeletal muscle inferior vena cava . Heart rate was recorded resting transmembrane potentials. These ef- and blood press.ure was monitored with...nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed through a

  15. Radical robot-assisted laparoscopic nephrectomy with thrombectomy in the vena cava.

    PubMed

    Estébanez Zarranz, J; Belloso Loidi, J; Gutierrez García, M A; Rubio Calaveras, V; Morales Higelmo, G; Melendo Tercilla, P; Busto Leis, L; Sanz Jaka, J P

    2018-04-23

    Renal cell carcinoma has a natural tendency to extend through the renal vein. When the thrombus reaches the vena cava, thrombectomy and the necessary reconstruction of the vena cava are typically performed by open pathway. Robot-assisted technology provides advantages for performing this complex technique, using a minimally invasive access. We present the technique we employed in the first case performed in our department. After performing renal artery embolisation, we conducted the surgery with the Vinci S robotic system. The main steps of the surgery are as follows: detachment and Kocher manoeuvre; release of the lower renal pole; clamping and sectioning of the renal artery; endocavitary ultrasound to locate the thrombus; placement of tourniquets in the vena cava below and above the renal veins and in the left renal vein; closure of the 3 tourniquets; opening of the vena cava; resection and extraction of the thrombus; suture of the vena cava; opening of the tourniquets; complete release of the kidney; bagging and extraction of the specimen. The surgery was performed without complications. The patient required a transfusion of 2 units of packed red blood cells and was discharged with modest renal failure (creatinine level of 1.60mg/dl). Radical nephrectomy with thrombectomy in the vena cava is a technique susceptible to severe complications and has, to date, been performed in few centres. We believe that the technique is reproducible and has clear advantages for our patients. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Effects of Ecklonia cava as fucoidan-rich algae on growth performance, nutrient digestibility, intestinal morphology and caecal microflora in weanling pigs.

    PubMed

    Choi, Yohan; Hosseindoust, Abdolreza; Goel, Akshat; Lee, Suhyup; Jha, Pawan Kumar; Kwon, Ill Kyong; Chae, Byung-Jo

    2017-01-01

    In the present study, role of increasing levels of Ecklonia cava (seaweed) supplementation in diets was investigated on growth performance, coefficient of total tract apparent digestibility (CTTAD) of nutrients, serum immunoglobulins, cecal microflora and intestinal morphology of weanling pigs. A total of 200 weaned pigs (Landrace×Yorkshire×Duroc; initial body weight 7.08±0.15 kg) were randomly allotted to 4 treatments on the basis of body weight. There were 5 replicate pens in each treatment including 10 pigs of each. Treatments were divided by dietary Ecklonia cava supplementation levels (0%, 0.05%, 0.1%, or 0.15%) in growing-finishing diets. There were 2 diet formulation phases throughout the experiment. The pigs were offered the diets ad libitum for the entire period of experiment in meal form. The pigs fed with increasing dietary concentrations of Ecklonia cava had linear increase (p<0.05) in the overall average daily gain, however, there were no significant differences in gain to feed ratio, CTTAD of dry matter and crude protein at both phase I and phase II. Digestibility of gross energy was linearly improved (p<0.05) in phase II. At day 28, pigs fed Ecklonia cava had greater (linear, p<0.05) Lactobacillus spp., fewer Escherichia coli ( E. coli ) spp. (linear, p<0.05) and a tendency to have fewer cecal Clostridium spp. (p = 0.077). The total anaerobic bacteria were not affected with supplementation of Ecklonia cava in diets. Polynomial contrasts analysis revealed that villus height of the ileum exhibited a linear increase (p<0.05) in response with the increase in the level of dietary Ecklonia cava . However, villus height of duodenum and jejunum, crypt depth, villus height to crypt depth ratio of different segments of the intestine were not affected. The results suggest that Ecklonia cava had beneficial effects on the growth performance, cecal microflora, and intestinal morphology of weanling pigs.

  17. Vena caval impalement: an unusual lawn mower injury in a child.

    PubMed

    Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P

    1998-06-01

    Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.

  18. Design Optimization of Vena Cava Filters: An application to dual filtration devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Wang, S L; Diachin, D P

    Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped modelmore » thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.« less

  19. ISOLATED ANOMALOUS INFERIOR VENA CAVA CONNECTION TO THE LEFT ATRIUM: REPORT OF A SUCCESSFUL SURGICAL CASE AND REVIEW OF THE LITERATURE.

    PubMed

    Richardson, James V.; Doty, Donald B.

    1979-03-01

    This report describes a rare case of isolated anomalous connection of the inferior vena cava to the left atrium. Patching of a surgically-created atrial septal defect and rerouting of caval drainage ino the right atrium effected a successful correction. This case brings to 18 the total number of reported cases in the literature in which the inferior vena cava was connected to the left atrium.

  20. Clinical Investigation Program.

    DTIC Science & Technology

    1979-10-01

    It has been established by a series of dog experiments using the-e-e-ctromagnetic flow meter that the blood flow in the inferior vena cava between...by thermodilution. Hepatic vein blood flow could be estimated by subtraction of the blood flow in the vena cava at the level of the renal veins from...the vena cava blood flow at the level of the diaphragm. This should be liver blood flow. It should be possible to sample pure hepatic vein blood by

  1. Application of an Adaptive Control Grid Interpolation Technique to Morphological Vascular Reconstruction: A Component of a Comprehensive Surgical Planning and Evaluation Tool

    DTIC Science & Technology

    2001-10-25

    a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV

  2. Cardiac Ischemia Model for +Gz Using Miniature Swine and Baboons

    DTIC Science & Technology

    2008-04-01

    VAP was tunneled subcutaneously to an incision in the ventral neck and placed in the superior vena cava just craniad to the right atrium through...was passed transcutaneously to the su- perior vena cava from the arm or to the inferior vena cava from the lower leg, using fl uoroscopy. The...Five control swine were maintained on a standard swine diet. Also, nine male baboons had a constrictor placed around the left anterior descending

  3. Structural and Functional Differences Between Porcine Aorta and Vena Cava.

    PubMed

    Mattson, Jeffrey M; Zhang, Yanhang

    2017-07-01

    Elastin and collagen fibers are the major load-bearing extracellular matrix (ECM) constituents of the vascular wall. Arteries function differently than veins in the circulatory system; however as a result from several treatment options, veins are subjected to sudden elevated arterial pressure. It is thus important to recognize the fundamental structure and function differences between a vein and an artery. Our research compared the relationship between biaxial mechanical function and ECM structure of porcine thoracic aorta and inferior vena cava. Our study suggests that aorta contains slightly more elastin than collagen due to the cyclical extensibility, but vena cava contains almost four times more collagen than elastin to maintain integrity. Furthermore, multiphoton imaging of vena cava showed longitudinally oriented elastin and circumferentially oriented collagen that is recruited at supraphysiologic stress, but low levels of strain. However in aorta, elastin is distributed uniformly, and the primarily circumferentially oriented collagen is recruited at higher levels of strain than vena cava. These structural observations support the functional finding that vena cava is highly anisotropic with the longitude being more compliant and the circumference stiffening substantially at low levels of strain. Overall, our research demonstrates that fiber distributions and recruitment should be considered in addition to relative collagen and elastin contents. Also, the importance of accounting for the structural and functional differences between arteries and veins should be taken into account when considering disease treatment options.

  4. Inferior Vena Cava Filters in Patients with Acute Pulmonary Embolism and Cancer.

    PubMed

    Stein, Paul D; Matta, Fadi; Lawrence, Frank R; Hughes, Mary J

    2018-04-01

    Administrative data have shown a lower mortality in hospitalized patients with pulmonary embolism and cancer who receive a vena cava filter. In the absence of a randomized controlled trial of vena cava filters in such patients, further investigation is necessary. Therefore, we performed this investigation using administrative data from a different database than used previously, and we investigate patients hospitalized in more recent years. We analyzed administrative data from the Premier Healthcare Database, 2010-2014, in patients hospitalized with pulmonary embolism and solid malignant tumors. Patients were identified on the basis of International Classification of Disease, Ninth Revision, Clinical Modification codes. Patients aged >60 years had a lower in-hospital all-cause mortality with vena cava filters than those who did not have filters, 346 of 4648 (7.4%) compared with 2216 of 19,847 (11.2%) (P < .0001) (relative risk 0.67). Among patients aged >60 years who received an inferior vena cava, all-cause mortality within 3 months was 704 of 4648 (15.1%), compared with 3444 of 19,847 (17.4%) among those who did not receive a filter (P < .0001) (relative risk 0.86). Elderly patients with pulmonary embolism and cancer may be a special population in whom inferior vena cava filters reduce in-hospital and 3-month all-cause mortality. Further investigation is needed, particularly in younger patients. Copyright © 2018. Published by Elsevier Inc.

  5. Vena Cava 3D Contrast-Enhanced MR Venography: A Pictorial Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Jiang; Zhou Kangrong; Chen Zuwang

    Three-dimensional contrast-enhanced magnetic resonance venography (CE MRV) is a sensitive and accurate method for diagnosing vena cava pathologies. The commonly used indirect approach involves a nondiluted gadolinium contrast agent injected into an upper limb vein or, occasionally, a pedal vein for assessment of the superior or inferior vena cava. In our studies, a coronal 3D fast multi-planar spoiled gradient-echo acquisition was used. A pre-contrast scan was obtained to ensure correct coverage of the region of interest. We initiated contrast-enhanced acquisition 15 sec after the start of contrast agent injection and performed the procedure twice. The image sets were obtained duringmore » two 20-30-sec breath hold, with a breathing rest of 5-6 sec, to obtain the first-pass and delayed arteriovenous phases. For patients with Budd-Chiari syndrome, a third acquisition coinciding with late venous phase was collected to visualize the hepatic veins, which was carried out by one additional acquisition after a 5-6-sec breathing time. This review describes the clinical application of 3D CE MRV in vena cava congenital anomalies, superior and inferior vena cava syndrome, Budd-Chiari syndrome, peripheral vein thrombosis extending to the vena cava, pre-operational evaluation in portosystemic shunting and post-surgical follow-up, and road-mapping for the placement and evaluation of complications of central venous devices.« less

  6. Right Atrial Anomalous Muscle Bundle Presenting with Acute Superior Vena Cava Syndrome and Pulmonary Embolism: Surgical Management.

    PubMed

    Madjarov, Jeko M; Katz, Michael G; Madjarova, Sophia; Madzharov, Svetozar; Arko, Frank R; Miller, David W; Robicsek, Francis

    2018-05-21

    An anomalous muscle bundle crossing the right atrial cavity represents a pathological finding with unproved clinical significance. This congenital anomaly may be difficult to recognize via echocardiography and could be confused with other intra-cavitary lesions. We report a case of a 53-year-old female presented to the cardio-vascular service with acute superior vena cava syndrome and sub-massive pulmonary embolism. The patient underwent venography confirming superior vena cava stenosis. A ventilation/perfusion lung scan showed two sizable perfusion defects due to pulmonary embolism. MRI and echocardiography imaging demonstrated right atrium mass. Surgery was then carried out using standard cardiopulmonary bypass; right atrial muscle bundle was excised and superior vena cava reconstruction was performed. The patient was discharged uneventfully and remains symptom-free at two years follow-up. In cases of nonmalignant pathology of superior vena cava syndrome, appropriate studies should be conducted to exclude potential congenital abnormalities such as this anomalous muscle bundle in the right atrium. Open heart surgery is a viable treatment option in select cases. Published by Elsevier Inc.

  7. Retrograde non trans-septal balloon mitral valvotomy in mitral stenosis with interrupted inferior vena cava, left superior vena cava, and hugely dilated coronary sinus.

    PubMed

    Nath, Ranjit Kumar; Soni, Dheeraj Kumar

    2015-12-01

    A 22-year-old woman with severe mitral stenosis was referred to us for further evaluation and management. She was found to have severe mitral stenosis, severe tricuspid regurgitation with dilated right atrium and right ventricle with persistent left superior vena cava and hugely dilated coronary sinus. Valve was suitable for balloon mitral valvotomy. Cardiac catheterization showed interrupted inferior vena cava with azygos continuation to right atrium and large left superior vena cava draining to coronary sinus which was very much dilated. Right trans-jugular approach was tried for balloon mitral valvotomy, but was unsuccessful due to a very large right atrium and coronary sinus. Retrograde non trans-septal approach was used and balloon valvotomy was done successfully using a 24 mm × 40 mm TYSHAK balloon without any major complication. Reduction in the transmitral pressure gradient on cardiac catheterization data and transthoracic echocardiography confirmed successful procedure. Balloon mitral valvotomy can be done successfully in patients with the above unusual cardiac anatomy with no major procedural complications. © 2015 Wiley Periodicals, Inc.

  8. Iatrogenic Diversion of Inferior Vena Cava into Left Atrium after Surgery for a Rare Combination of Congenital Heart Diseases

    PubMed Central

    Sabzi, Feridoun

    2016-01-01

    Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261

  9. Anomalous dual drainage of the right pulmonary veins in a patient with cor triatriatum: report of a case without scimitar sign.

    PubMed

    Tansel, T; Harmandar, B; Dayioglu, E; Onursal, E

    2006-02-01

    The majority of patients with partial anomalous drainage of pulmonary veins are asymptomatic during infancy and childhood. Patients with significant left-to-right shunt develop symptoms and benefit from early corrective surgery. Anomalous pulmonary veins draining into inferior vena cava is very rare and frequently encountered in association with scimitar syndrome. The purpose of this case report is to describe a non-scimitar patient with cor triatriatum who had anomalous dual drainage of right pulmonary veins into inferior vena cava/left atrium and anomalous connection of persistent left superior vena cava with a common pulmonary venous chamber. The patient underwent an operation with redirection of anomalous pulmonary venous drainage into left atrium and ligation of persistent left superior vena cava.

  10. Mediastinal fibrosis and superior vena cava syndrome.

    PubMed

    Novella Sánchez, Laura; Sanz Herrero, Francisco; Berraondo Fraile, Javier; Fernández Fabrellas, Estrella

    2013-08-01

    Superior vena cava syndrome is a clear sign for clinicians of infiltrative mediastinal involvement, usually caused by neoplasms in this location, and it is an indicator of poor prognosis. However, other diseases of benign origin can also cause these alterations. We present the case of a 34-year-old patient who debuted with symptoms of superior vena cava syndrome due to idiopathic mediastinal fibrosis, which presented a torpid evolution and few therapeutic alternatives. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.

  11. [Superior vena cava syndrome--clinical aspects, etiology and case reports].

    PubMed

    Serdarevic, M; Löhr, E; Reidemeister, J C

    1984-06-01

    The so-called superior-Cava Syndrome is caused by obstructions by centrally localized tumors by thrombosis or by inflammations of the mediastinum. In cases of tumorous infiltration a graft can be inserted. The different phenomena of thrombosis caused by nutritial catheters and pace makers are of clinical importance. Acute thrombosis of the brachio-cervical veins and the Vena Cava can be treated successfully by means of thrombolysis. Besides CT bilateral brachial phlebography communicates optimal information concerning localization of vascular obstruction and collateral circuits.

  12. Hand-assisted laparoscopic radical nephrectomy in the treatment of a renal cell carcinoma with a level II vena cava thrombus.

    PubMed

    Kovac, Jason R; Luke, Patrick P

    2010-01-01

    Excision of renal cell carcinoma (RCC) with corresponding vena cava thrombus is a technical challenge requiring open resection and vascular clamping. A 58 year old male with a right kidney tumor presented with a thrombus extending 1 cm into the vena cava. Using a hand-assisted transperitoneal approach through a 7 cm gel-port, the right kidney was dissected and the multiple vascular collaterals supplying the tumor were identified and isolated. The inferior vena cava was mobilized 4 cm cephalad and 4 cm caudal to the right renal vein. Lateral manual traction was applied to the right kidney allowing the tumor thrombus to be retracted into the renal vein, clear of the vena cava. After laparoscopic ultrasonographic confirmation of the location of the tip of the tumor thrombus, an articulating laparoscopic vascular stapler was used to staple the vena cava at the ostium of the right renal vein. This allowed removal of the tumor thrombus without the need for a Satinsky clamp. The surgery was completed in 243 minutes with no intra-operative complications. The entire kidney and tumor thrombus was removed with negative surgical margins. Estimated blood loss was 300 cc. We present a laparoscopic resection of a renal mass with associated level II thrombus using a hand-assisted approach. In patients with minimal caval involvement, our surgical approach presents an option to the traditional open resection of a renal mass.

  13. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    PubMed

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (p<0.001). Evaluation of CTV data sets was significantly facilitated with flexible delayed scan time of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep venous thrombosis in perinatal period.

    PubMed

    Köcher, Martin; Krcova, Vera; Cerna, Marie; Prochazka, Martin

    2009-04-01

    To evaluate the feasibility and efficacy of the retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep vein thrombosis in the perinatal period and to discuss the technical demands associated with the filter's implantation and retrieval. Between 1996 until 2007, eight women (mean age 27.4 years, range 20-42 years) with acute deep iliofemoral venous thrombosis in the perinatal period of pregnancy and increased risk of pulmonary embolism during delivery were indicated for retrievable Günther Tulip Vena Cava Filter implantation. All filters were inserted and removed under local anesthesia from the jugular approach. The Günther Tulip Vena Cava Filter was implanted suprarenally in all patients on the day of caesarean delivery. In follow-up cavograms performed just before planned filter removal, no embolus was seen in the filter in any patient. In all patients the filter was retrieved without complications on the 12th day after implantation. Retrievable Günther Tulip Vena Cava Filters can be inserted and removed in patients during the perinatal period without major complications.

  15. GdnHCl-induced unfolding intermediate in the mitochondrial carbonic anhydrase VA.

    PubMed

    Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Hassan, Md Imtaiyaz; Ahmad, Faizan

    2016-10-01

    Carbonic anhydrase VA (CAVA) is a mitochondrial enzyme belonging to the α-family of CAs, which is involved in several physiological processes including ureagenesis, lipogenesis, gluconeogenesis and neuronal transmission. Here, we have tried to understand the folding mechanism of CAVA using guanidine hydrochloride (GdnHCl)-induced denaturation at pH 8.0 and 25°C. The conformational stability was measured from the GdnHCl-induced denaturation study of CAVA monitored by circular dichroism (CD) and fluorescence measurements. On increasing the concentration of GdnHCl up to 5.0, a stable intermediate was observed between the concentrations 3.25M to 3.40M of the denaturant. However, CAVA gets completely denatured at 4.0M GdnHCl. The existence of a stable intermediate state was validated by 1-anilinonaphthalene-8-sulfonic acid (ANS binding) fluorescence and near-UV CD measurements. In silico studies were also performed to analyse the effect of GdnHCl on the structure and stability of CAVA under explicit conditions. Molecular dynamics simulations for 40ns were carried out and a well-defined correlation was established for both in vitro and in silico studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Heart block and cardiac embolization of fractured inferior vena cava filter.

    PubMed

    Abudayyeh, Islam; Takruri, Yessar; Weiner, Justin B

    2016-01-01

    A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures. The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process. This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation. Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.

  17. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    PubMed

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  18. [Syndrome of vena cava obstruction in oncology].

    PubMed

    Kohútek, F; Litvin, I; Tamášová, M; Bystrický, B

    2013-01-01

    Superior vena cava syndrome (SVCO) is caused by compression of superior vena cava and restriction of blood flow to the heart. The most common underlying condition in cancer patients is lung cancer or other malignancy expanding in the upper mediastinum. SVCO belongs to oncological emergencies and requires a prompt dia-gnostic work up and treatment. A 79year old man with a history of right sided stage IIIB nonsmall cell lung cancer, after two cycles of chemotherapy, was admitted to hospital with clinical signs of SVCO. The initial radiotherapy brought no relief of symptoms and due to deterioration of patients status during the treatment we proceeded to self expanding caval stent insertion. This was followed by immediate resolution of SVCO symptoms. In the second case we describe a 56year old female with a newly dia-gnosed diffuse large B cell lymphoma who presented with SVCO symptoms when referred to our outpatient chemotherapy department. She had no history of previous treatment and she complained of a rapid face and eyelid edema and intractable cough in the last two days. CT scan revealed mediastinal mass compressing the superior vena cava. Urgent antilymphoma chemotherapy (RCHOP schedule) was commenced and yielded quick resolution of her symp-toms. Superior vena cava syndrome is a medical emergency in oncological patients usually caused by external compression of cava by lung cancer, lymphoma, other tumors, less frequently, from a thrombosis of indwelling central venous catheter. Multidiscip-linary cooperation among radiation and medical oncologists and interventional radiologists is needed in order to provide an early treatment without an undue delay.

  19. Human aortic allograft: an excellent conduit choice for superior vena cava reconstruction

    PubMed Central

    2014-01-01

    Superior vena cava (SVC) reconstruction is occasionally required in the treatment of benign and malignant conditions. We report a patient with symptomatic SVC obstruction secondary to mediastinal fibrosis successfully reconstructed with an aortic allograft. PMID:24428914

  20. Compression of the Inferior Vena Cava by the Right Iliac Artery: A Rare Variant of May-Thurner Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fretz, V.; Binkert, C. A., E-mail: Christoph.Binkert@ksw.c

    May-Thurner syndrome is known as compression of the left common iliac vein by the right common iliac artery. We describe a case of an atypical compression of the inferior vena cava by the right common iliac artery secondary to a high aortic bifurcation. Despite an extensive collateral network, there was a significant venous gradient between the iliac veins and the inferior vena cava above the compression. After stenting the venous pressure gradient disappeared. Follow-up 4 months later revealed a good clinical response with a patent stent.

  1. Preparative isolation and purification of phlorotannins from Ecklonia cava using centrifugal partition chromatography by one-step.

    PubMed

    Lee, Ji-Hyeok; Ko, Ju-Young; Oh, Jae-Young; Kim, Chul-Young; Lee, Hee-Ju; Kim, Jaeil; Jeon, You-Jin

    2014-09-01

    Various bioactive phlorotannins of Ecklonia cava (e.g., dieckol, eckol, 6,6-bieckol, phloroglucinol, phloroeckol, and phlorofucofuroeckol-A) are reported. However, their isolation and purification are not easy. Centrifugal partition chromatography (CPC) can be used to efficiently purify the various bioactive-compounds efficiently from E. cava. Phlorotannins are successfully isolated from the ethyl acetate (EtOAc) fraction of E. cava by CPC with a two-phase solvent system comprising n-hexane:EtOAc:methanol:water (2:7:3:7, v/v) solution. The dieckol (fraction I, 40.2mg), phlorofucofuroeckol-A (fraction III, 31.1mg), and fraction II (34.1mg) with 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are isolated from the crude extract (500 mg) by a one-step CPC system. The purities of the isolated dieckol and phlorofucofuroeckol-A are ⩾90% according to high performance liquid chromatography (HPLC) and electrospray ionization multi stage tandem mass spectrometry analyses. The purified 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are collected from fraction II by recycle-HPLC. Thus, the CPC system is useful for easy and simple isolation of phlorotannins from E. cava. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Partial abnormal drainage of superior and inferior caval veins into the left atrium: two case reports.

    PubMed

    Chessa, Massimo; Carminati, Mario; Cinteză, Eliza Elena; Butera, Gianfranco; Giugno, Luca; Arcidiacono, Carmelo; Piazza, Luciane; Bulescu, Nicolae Cristian; Pome, Giuseppe; Frigiola, Alessandro; Giamberti, Alessandro

    2016-01-01

    Abnormal connection of the right superior caval vein to the left atrium is an uncommon systemic vein drainage anomaly, with only a few cases reported among congenital heart disease (CHD), around 20 cases published in the medical literature. The inferior vena cava connection with the left atrium, also very rare, can appear directly or in heterotaxy. Clinical suspicion arises due to the presence of cyanosis in the absence of other specific clinical signs (without other associated CHD). We present the cases of two children with abnormal superior and inferior systemic venous return. The first case is an abnormal connection of right superior vena cava to the left atrium associated with persistent left superior vena cava draining into the right atrium through the coronary sinus. The second case is an interruption of the inferior vena cava with hemiazygos continuation, drained into the left superior vena cava, which drained into the left atrium. The diagnosis was imagistic - echocardiography and angiography. Surgical treatment solutions vary from one case to another, usually following anatomic correction. Hypoxia accompanied by cyanosis must bring into question the pathology of systemic venous drainage anomaly, after other common causes have been excluded. Surgery is indicated in all cases due to the risk associated with the presence of right-to-left shunt.

  3. Spectroscopic and MD simulation studies on unfolding processes of mitochondrial carbonic anhydrase VA induced by urea.

    PubMed

    Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz

    2016-09-01

    Carbonic anhydrase VA (CAVA) is primarily expressed in the mitochondria and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis and neuronal transmission. To understand the biophysical properties of CAVA, we carried out a reversible urea-induced isothermal denaturation at pH 7.0 and 25°C. Spectroscopic probes, [θ]222 (mean residue ellipticity at 222 nm), F344 (Trp-fluorescence emission intensity at 344 nm) and Δε280 (difference absorption at 280 nm) were used to monitor the effect of urea on the structure and stability of CAVA. The urea-induced reversible denaturation curves were used to estimate [Formula: see text], Gibbs free energy in the absence of urea; Cm, the mid-point of the denaturation curve, i.e. molar urea concentration ([urea]) at which ΔGD = 0; and m, the slope (=∂ΔGD/∂[urea]). Coincidence of normalized transition curves of all optical properties suggests that unfolding/refolding of CAVA is a two-state process. We further performed 40 ns molecular dynamics simulation of CAVA to see the dynamics at different urea concentrations. An excellent agreement was observed between in silico and in vitro studies.

  4. Retrievable vena cava filters in trauma patients for high-risk prophylaxis and prevention of pulmonary embolism.

    PubMed

    Allen, Todd L; Carter, Jody L; Morris, Brad J; Harker, Colleen P; Stevens, Mark H

    2005-06-01

    Venous thromboembolic (VTE) disease remains a significant cause of morbidity for trauma patients because many patients have injuries that may preclude effective VTE prevention and treatment. Retrievable vena cava filters may prove beneficial in this subset of trauma patients. Trauma patients at risk for VTE were identified and managed by institutional protocol. Patients who required a vena cava filter were managed with a device that could be retrieved or left in situ. A retrospective review of medical records was used to identify the use, indications, and complications associated with a retrievable filter. Fifty-three retrievable filters were placed in 51 patients. Two of these patients received a second filter, and 1 received a filter in the superior vena cava. Thirty-two filters were placed prophylactically, whereas 21 were placed for demonstrated venous thromboembolism (VTE). Retrieval was successful in 24 of 25 attempts. Twenty-nine filters became permanent: 10 for continued contraindications to anticoagulation without known VTE, 12 for known VTE and continued contraindications to anticoagulation, 1 for technical reasons, and 6 because of patient death. There were no complications of bleeding, device migration or thrombosis, infection, or pulmonary embolism. A retrievable vena cava filter appears safe and effective for the prevention of pulmonary embolism in the high-risk trauma patient who cannot receive anticoagulation.

  5. Non-retrieval of inferior vena cava filters as a patient safety concern: evaluation of a new process improvement project to increase retrieval rates in a vascular and interventional radiology clinic.

    PubMed

    Brown, Joshua; Talbert, Jeffery; Pennington, Ryan; Han, Qiong; Raissi, Driss

    2018-01-01

    Retrieval of inferior vena cava filters (IVCFs) is important to decrease the long-term risk of complications associated with indwelling devices. Our hospital experienced low retrieval rates and implemented a low-cost intervention and evaluation for quality improvement. The working hypothesis was that a simple, mailed letter intervention could increase retrieval rates by increasing patient and primary care provider knowledge of the need for retrieval. For all prospective patients who received a retrievable IVCF during the intervention period from January 1, 2014 to February 29, 2016, patients and their primary care providers were mailed letters encouraging contact with the clinic for evaluation of eligibility for retrieval. The main outcome was retrieval of the IVCF if clinically indicated with a secondary outcome of time-to-retrieval. A pre-intervention control group from October 1, 2011 to December 31, 2013 was used to evaluate the impact of the intervention. Competing risks, time-to-event analysis was used to compare the pre- and post-intervention period retrieval rates correcting for patients who died during follow-up. Between the pre- and post-intervention periods, crude retrieval rates increased from 4.4% to 8.1% with a 12-fold change at comparable time points. The time-to-retrieval in the pre-intervention period was a mean (SD) of 503 (207) days with a median (IQR) of 505 (301-742). In the post-intervention period, time-to-retrieval was a mean (SD) of 119 (83) days and with median (IQR) of 128 (38-164) days. This low-cost intervention significantly increased retrieval rates in a single clinic. However, retrieval rates remain low and can be further improved. Ongoing interventions, including improved patient follow-up and physician education, are being implemented to further improve retrieval and use of inferior vena cava filters. Implanting clinics should implement quality improvement initiatives to improve patient care and follow-up with IVCFs to ensure retrievals occur once clinically relevant in order to minimize long-term complications.

  6. Particle radiotherapy, a novel external radiation therapy, versus liver resection for hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus: A matched-pair analysis.

    PubMed

    Komatsu, Shohei; Kido, Masahiro; Asari, Sadaki; Toyama, Hirochika; Ajiki, Tetsuo; Demizu, Yusuke; Terashima, Kazuki; Okimoto, Tomoaki; Sasaki, Ryohei; Fukumoto, Takumi

    2017-12-01

    Hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus carries a dismal prognosis, and the feasibility of local treatment has remained controversial. The present study aimed to compare the outcomes of particle radiotherapy and liver resection in patients with hepatocellular carcinoma with inferior vena cava tumor thrombus. Thirty-one and 19 patients, respectively, underwent particle radiotherapy and liver resection for hepatocellular carcinoma with inferior vena cava tumor thrombus. A matched-pair analysis was undertaken to compare the short- and long-term outcomes according to tumor stage determined using the tumor-node-metastasis classification. Both stages IIIB and IV (IVA and IVB) patients were well-matched for 12 factors, including treatment policy and patient and tumor characteristics. The median survival time of matched patients with stage IIIB tumors in the particle radiotherapy group was greater than that in the liver resection group (748 vs 272 days, P = .029), whereas no significant difference was observed in the median survival times of patients with stage IV tumors (239 vs 311 days, respectively). There were significantly fewer treatment-related complications of grade 3 or greater in the particle radiotherapy group (0%) than in the liver resection group (26%). Particle radiotherapy is potentially preferable in hepatocellular carcinoma patients with stage IIIB inferior vena cava tumor thrombus and at least equal in efficiency to liver resection in those with stage IV disease, while causing significantly fewer complications. Considering the relatively high survival and low invasiveness of particle radiotherapy when compared to liver resection, this approach may represent a novel treatment modality for hepatocellular carcinoma with inferior vena cava tumor thrombus. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onat, Levent, E-mail: levonat2@yahoo.com; Ganiyusufoglu, Ali Kursat; Mutlu, Ayhan

    We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9).more » Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.« less

  8. Successful balloon dilatation for postoperative caval stenosis caused by primary venorrhaphy for traumatic retro-hepatic caval injury in a three-year-old child: Report of a case.

    PubMed

    Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru

    2015-09-01

    Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. A Rare Vascular Anomaly during Central Venous Catheterization: A Persistent Left-Sided Superior Vena Cava.

    PubMed

    Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm

    2018-01-01

    A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.

  10. [Successful repair of total anomalous pulmonary venous connection and incomplete endocardial cushion defect associated with left isomerism].

    PubMed

    Mizuno, A; Nakamura, Y; Takayasu, H; Saitoh, H

    1993-05-01

    Successful repair of a 8-month-old girl with polysplenia was reported. The cardiovascular anomalies were TAPVC (II b), incomplete ECD, interruption of inferior vena cava with hemiazygos continuation, bilateral superior vena cava, and left superior vena cava draining into the coronary sinus. Cardiopulmonary bypass was established with ascending aortic perfusion and caval cannulation. A left superior vena cava was directly cannulated after establishing partial bypass. In this case the left pulmonary vein drained into the right atrium near the orifice of the coronary sinus, so the atrial septal flap was made and sutured between the orifice of the left pulmonary vein and the coronary sinus in order to avoid late pulmonary vein obstruction. Then, atrium was separated by an intraatrial baffle which was sutured to the atrial septal flap. Recently, it becomes possible to surgical repair of polysplenia syndrome according to the advancements of the diagnostic methods, cardiopulmonary bypass, and the technique of the open heart surgery.

  11. Use of contrast echocardiography in diagnosis of anomalous connection of right superior vena cava to left atrium.

    PubMed Central

    Truman, A T; Rao, P S; Kulangara, R J

    1980-01-01

    A 4-month-old infant with cyanosis but without other abnormal cardiac findings is presented in whom the diagnosis of anomalous systemic venous connection to the left atrium was made by contrast echocardiography. The diagnosis was later confirmed by cardiac catheterisation and selective cineangiography. When saline was injected into a vein on the dorsum of each hand while echocardiographically recording the cardiac structures, the left atrium, left ventricle, and aorta were opacified without visualisation of the right ventricle. Similar study with injection into the right foot produced opacification of the right ventricle without visualisation of the left-sided structures. These data suggested normal drainage of the inferior vena cava with anomalous connection of the superior vena cava to the left atrium. A review of the previously reported cases of anomalous connection of the right superior vena cava to the left atrium is presented together with the possible embryological origin of this anomaly. Images PMID:7459157

  12. Construction of Continental Crust at the Central American and Philippines Arc Systems

    NASA Astrophysics Data System (ADS)

    Whattam, S. A.; Stern, R. J.

    2016-12-01

    Whether or not magmatic arcs evolve compositionally with time and the processes responsible remain controversial. Resolution of this question requires reconstructing arc geochemical evolution at the level of discrete arc systems, as has been done for IBM, Central America, and the Greater Antilles. Emphasis should be on arcs built on oceanic crust because interaction with continental crust complicates interpretations. The Philippines are a particularly attractive target because this may be the best example where proto-continental crust has been generated and processed in Cretaceous and younger time. Here, we show how this question could be addressed for the Philippines using the well-studied Central American Volcanic Arc System (CAVAS) as an example. For the CAVAS, we avoided the northern arc segment because these are (Guatemala) or maybe (El Salvador) sections built on continental crust. Geochemical and isotopic data were compiled for 1031 samples of lavas and intrusive rocks from the 1100 km-long segment built on thickened, initially plume-derived oceanic crust over its 75 million year lifespan (Panama, Costa Rica, Nicaragua) . The most striking observation is the overall evolution of the CAVAS to more incompatible element enriched and ultimately continental-like compositions with time. Models entailing progressive arc magmatic enrichment are generally supported by the CAVAS record. Progressive enrichment of the oceanic CAVAS with time reflects changes in mantle wedge composition and decreased melting due to arc crust thickening, which was kick-started by the involvement of enriched plume mantle. Progressive crustal thickening and associated changes in the sub-arc thermal regime resulted in decreasing degrees of partial melting over time, which allowed for progressive enrichment of the CAVAS and ultimately the production of continental-like crust in Panama and Costa Rica by 16-10 Ma. Our similar study of the Philippine Arc system is in its infancy but earlier studies have shown that older magmatic rocks are tholeiitic and MORB-like whereas younger ones are invariably calc-alkaline and arc-like. Results of the Philippines Arc study will be compared with the CAVAS and other magmatic arc systems comprised of continental crust.

  13. Intraatrial baffle repair of isolated ventricular inversion with left atrial isomerism.

    PubMed

    McElhinney, D B; Reddy, V M; Silverman, N H; Hanley, F L

    1996-11-01

    Isolated ventricular inversion with left atrial isomerism, partial anomalous pulmonary venous connection, and interruption of the inferior vena cava with azygos continuation to a right superior vena cava was diagnosed by echocardiography in a neonate. At 48 days of age, the patient underwent successful anatomic correction with redirection of flow from the superior vena cava and hepatic veins to the left-sided tricuspid valve, and flow from the pulmonary veins to the right-sided mitral valve. In the present report, the surgical techniques of this case are described, along with a survey of the surgical literature covering anatomic repair of isolated ventricular inversion.

  14. Nutcracker syndrome and deep venous thrombosis in a patient with duplicated inferior vena cava.

    PubMed

    Yoshida, Ricardo de Alvarenga; Yoshida, Winston Bonetti; Costa, Renato Fanchiotti; Nacif, Marcelo Souto; Sobreira, Marcone Lima; Jaldin, Rodrigo Gibin

    2016-04-01

    Duplicated inferior vena cava is a rare anomaly, and thrombosis in one or both segments is even less frequent. We present a case of deep venous thrombosis of the left lower limb involving the popliteal, femoral, and iliac veins as well as the left segment of the duplicated vena cava and nutcracker syndrome. After catheter-directed thrombolysis complemented by mechanical thrombolysis, the compromised veins had complete revascularization; the nutcracker syndrome was treated with stent placement, followed by the use of anticoagulants. There was technical success and complete recovery of the patient. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Abdominal wall phlebitis due to Prevotella bivia following renal transplantation in a patient with an occluded inferior vena cava.

    PubMed

    Janssen, S; van Donselaar-van der Pant, K A M I; van der Weerd, N C; Develter, W; Bemelman, F J; Grobusch, M P; Idu, M M; Ten Berge, I J M

    2013-02-01

    Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous collateral veins of the abdominal wall contra-laterally to the renal transplant. Cultures from abdominal wall micro-abscesses yielded Prevotella bivia as the causative agent. This complication has not been described before in the context of renal transplantation. The pathogenesis and management of this serious complication are discussed in this paper.

  16. Repeatable noninvasive measurement of mouse myocardial glucose uptake with 18F-FDG: evaluation of tracer kinetics in a type 1 diabetes model.

    PubMed

    Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N

    2013-09-01

    A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.

  17. Peroperative electrocardiographic control of catheter tip position during implantation of femoral venous ports.

    PubMed

    Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis

    2015-01-01

    Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

  18. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report.

    PubMed

    Higutchi, C; Sarraf, Y S; Nardino, É P; Pereira, W M G; Daboin, B E G; Carvalho, L E W; Correa, J A

    2017-01-01

    This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins) who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC) and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis.

  19. Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure.

    PubMed

    Ait-Oufella, Hafid; Boelle, Pierre-Yves; Galbois, Arnaud; Baudel, Jean-Luc; Margetis, Dimitri; Alves, Mikael; Offenstadt, Georges; Maury, Eric; Guidet, Bertrand

    2012-06-28

    Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.

  20. [How efficient and safe are Vena-cava-filters?].

    PubMed

    Kluge, Stefan

    2015-08-01

    In the last 30 years patients with pulmonary embolism have increasingly often been implanted with a vena cava filter. Evidence of safety and efficacy in comparison to pure anticoagulation are in short supply. Re-removable filter reduces neither the risk of recurrence nor mortality, according to a study now revealed.

  1. Unidentified retained inferior vena cava myxoma detected by intra-operative trans-oesophageal echocardiography.

    PubMed

    Vohra, H A; Phillips, N J; Nel, L; Diprose, P; Ohri, S K

    2010-06-01

    We report a unilateral right atrial familial myxoma with a multicentric nature discovered during cardiac surgery. After the patient was weaned off cardiopulmonary bypass, an inferior vena cava myxoma was discovered with intra-operative trans-oesophageal echocardiogram (TOE) which had been missed preoperatively and during surgery.

  2. Biofouling attractants from a brown marine alga Ecklonia cava.

    PubMed

    Sidharthan, M; Viswanadh, G S; Kim, Kyoung Ho; Kim, Hyuk Jun; Shin, H W

    2007-04-01

    In recent years, industrial pollutants and the mountain forest fire ashes released into seawater cause damage to the marine environment, mainly it reduces the algal productivity in the inter tidal region. To get recover from the stress due to pollutants and to increase the growth and development of biofouling algae (benthic organisms), Ecklonia cava extract was investigated for its biofouling attracting efficiency. Bioactive guided fractions of E. cava extract derived from column chromatography were tested against spore attachment of a fouling alga, Ulva pertusa. Fraction B showed increased spore attachment rate with a maximum of 92 +/- 5%. This fraction was further analysed on HPLC, GC-Mass and NMR, deduced as pentadecanoic acid.

  3. Percutaneous retrieval of a right atrioventricular embolus.

    PubMed

    Davies, R P; Harding, J; Hassam, R

    1998-01-01

    Percutaneous retrieval of a 12-cm-long serpiginous clot lodged in the right atrium and ventricle is reported. Following bilateral common femoral vein puncture, a Bird's Nest cava filter was first positioned ready to deploy immediately below the renal veins via the right femoral vein. From the left femoral vein, a Cook intravascular retrieval basket was advanced to the right atrium. Under transthoracic echocardiographic visualization, the basket was used to engage, trap, and gently withdraw the clot in a single long strand below the prepositioned inferior vena cava filter. The filter was immediately deployed, leaving the clot trapped inferior to the renal veins, in the cava and left iliac vein. The patient remained well and asymptomatic at discharge.

  4. Unusual collateral vessel from right subclavian vein to left atrium, a rare complication of superior vena cava obstruction.

    PubMed

    Parsaee, Mozhgan; Pouraliakbar, Hamidreza; Ghadrdoost, Behshid; Moosavi, Jamal; Behjati, Mohaddeseh

    2018-06-10

    The most commonly reported collateral systems in the setting of superior vena cava obstruction are azygos venous system, vertebral venous system, external and internal thoracic venous system based on McLntire and Sykes classification. A 49-year-old female with renal disease complained dyspnea on exertion. Transesophageal echocardiography showed significant mitral annular calcification, large multi-lobulated mass at posterior aspect of RA, and complete obstruction of superior vena cava by thrombus formation. Computed tomography angiography showed a collateral vein to the left atrium (LA) roof. This case report is the first one which shows development of collateral vein from right subclavian to LA. © 2018 Wiley Periodicals, Inc.

  5. Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br; Santos, Aline Cristine Barbosa; Tannuri, Uenis

    We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge ofmore » the stent.« less

  6. Abnormal connection of the inferior vena cava to the left atrium with double outlet right ventricle and heterotaxia: a case report.

    PubMed

    Günal, N; Bilgiç, A; Lenk, M K; Yurdakul, Y; Sarigül, A; Ispir, S

    1996-03-01

    A 4-year-old boy with abnormal connection of the inferior vena cava to the left atrium and double outlet right ventricle and right atrial isomerism is presented. The anomalies were detected by echocardiography and angiography, and later verified through surgical intervention.

  7. Scimitar sign with normal pulmonary venous drainage and anomalous inferior vena cava.

    PubMed Central

    Herer, B; Jaubert, F; Delaisements, C; Huchon, G; Chretien, J

    1988-01-01

    A case of the scimitar sign due to an anomaly of the right sided pulmonary vein with normal drainage into the left atrium was associated with an azygos continuation of the inferior vena cava. Digital subtraction angiography allows the identification of these rare congenital vascular malformations. Images PMID:3175980

  8. Inferior Vena Cava Filters: Current and Future Concepts.

    PubMed

    Kaufman, John Andrew

    2018-01-01

    The inferior vena cava filter clinical environment is notable for the degree of controversy, uncertainty, and fear associated with these devices by both physicians and the public. This article reviews some of the more important current issues with these devices as well as emerging and future trends. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Resection of giant right atrial lymphoma using vacuum-assisted cardiopulmonary bypass without snaring the inferior vena cava.

    PubMed

    Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei

    2004-08-01

    A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.

  10. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    PubMed

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  11. Estimation and tracking of AP-diameter of the inferior vena cava in ultrasound images using a novel active circle algorithm.

    PubMed

    Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew

    2018-05-04

    Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Implantation of VVI pacemaker in a patient with dextrocardia, persistent left superior vena cava, and sick sinus syndrome

    PubMed Central

    Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun

    2017-01-01

    Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908

  13. Adult Wilms tumor with inferior vena cava thrombus and distal deep vein thrombosis - a case report and literature review.

    PubMed

    Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel

    2018-02-23

    Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.

  14. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    PubMed

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access and where combined long-term central venous catheter placement using the subclavian vein is desirable.

  15. Modification of hemi-Fontan operation for patients with functional single ventricle and anomalous pulmonary venous connection to the superior vena cava: mid-term results†

    PubMed Central

    Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo

    2016-01-01

    OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898

  16. Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.

    PubMed

    Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée

    2012-10-01

    We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.

  17. Transection of the inferior vena cava from blunt thoracic trauma: case reports.

    PubMed

    Peitzman, A B; Udekwu, A O; Pevec, W; Albrink, M

    1989-04-01

    Blunt thoracic trauma is a frequent cause of death in multiple trauma victims. Myocardial rupture may occur in up to 65% of patients who die with thoracic injuries. Two cases are presented with intrapericardial transection of the inferior vena cava, pericardial rupture, and myocardial rupture from blunt thoracic trauma. Both patients died.

  18. Retrieval of Cement Embolus from Inferior Vena Cava After Percutaneous Vertebroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athreya, S., E-mail: sathreya@stjoes.c; Mathias, N.; Rogers, P.

    Percutaneous vertebroplasty is an accepted treatment for painful vertebral compression fractures caused by osteoporosis and malignant disease. Venous leakage of cement and pulmonary cement embolism have been reported complications. We describe a paravertebral venous cement leak resulting in the deposition of a cement cast in the inferior vena cava and successful retrieval of the cement embolus.

  19. Ultrasound-Accelerated, Catheter-Directed Thrombolysis for Inferior Vena Cava Thrombosis After an Orthotopic Liver Transplant

    PubMed Central

    Latchana, Nicholas; Dowell, Joshua D.; Taani, Jamal Al; Michaels, Anthony; Elkhammas, Elmadhi; Black, Sylvester M.

    2015-01-01

    Inferior vena cava thrombosis is a rare occurrence after an orthotopic liver transplant that is associated with a high rate of retransplant and mortality. There is no consensus regarding the optimal therapeutic strategy. Surgical management, including thrombectomy with revision of the cavocaval anastomosis, has been described. With the use of endovascular therapies, several minimally invasive approaches are available that are effective and avoid the high morbidity associated with reoperative surgery. We describe our successful experience using an approach after a liver transplant in which the inferior vena cava thrombosis in a patient presenting with acute renal failure, anorexia, weight loss, and fatigue using an ultrasound-accelerated, catheter-directed thrombolysis platform in conjunction with systemic anticoagulation. PMID:24918871

  20. Partial anomalous pulmonary venous connection to the superior vena cava.

    PubMed

    Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto

    2011-04-01

    We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Do the stars align? Distribution of high-quality ratings of healthcare sectors across US markets.

    PubMed

    Figueroa, Jose; Feyman, Yevgeniy; Blumenthal, Daniel; Jha, Ashish

    2018-04-01

    The US government created five-star rating systems to evaluate hospital, nursing homes, home health agency and dialysis centre quality. The degree to which quality is a property of organisations versus geographical markets is unclear. To determine whether high-quality healthcare service sectors are clustered within US healthcare markets. Using data from the Centers for Medicare and Medicaid Services' Hospital, Dialysis, Nursing Home and Home Health Compare databases, we calculated the mean star ratings of four healthcare sectors in 304 US hospital referral regions (HRRs). For each sector, we ranked HRRs into terciles by mean star rating. Within each HRR, we assessed concordance of tercile rank across sectors using a multirater kappa. Using t-tests, we compared characteristics of HRRs with three to four top-ranked sectors, one to two top-ranked sectors and zero top-ranked sectors. Six HRRs (2.0% of HRRs) had four top-ranked healthcare sectors, 38 (12.5%) had three top-ranked health sectors, 71 (23.4%) had two top-ranked sectors, 111 (36.5%) had one top-ranked sector and 78 (25.7%) HRRs had no top-ranked sectors. A multirater kappa across all sectors showed poor to slight agreement (K=0.055). Compared with HRRs with zero top-ranked sectors, those with three to four top-ranked sectors had higher median incomes, fewer black residents, lower mortality rates and were less impoverished. Results were similar for HRRs with one to two top-ranked sectors. Few US healthcare markets exhibit high-quality performance across four distinct healthcare service sectors, suggesting that high-quality care in one sector may not be dependent on or improve care quality in other sectors. Policies that promote accountability for quality across sectors (eg, bundled payments and shared quality metrics) may be needed to systematically improve quality across sectors. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Feasibility and reliability of pocket-size ultrasound examinations of the pleural cavities and vena cava inferior performed by nurses in an outpatient heart failure clinic.

    PubMed

    Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn

    2015-08-01

    Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.

  3. Effect of pH on structure, function, and stability of mitochondrial carbonic anhydrase VA.

    PubMed

    Idrees, Danish; Shahbaaz, Mohd; Bisetty, Krishna; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz

    2017-02-01

    Mitochondrial carbonic anhydrase VA (CAVA) catalyzes the hydration of carbon dioxide to produce proton and bicarbonate which is primarily expressed in the mitochondrial matrix of liver, and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis, and neuronal transmission. To understand the effect of pH on the structure, function, and stability of CAVA, we employed spectroscopic techniques such as circular dichroism, fluorescence, and absorbance measurements in wide range of pH (from pH 2.0 to pH 11.5). CAVA showed an aggregation at acidic pH range from pH 2.0 to pH 5.0. However, it remains stable and maintains its secondary structure in the pH range, pH 7.0-pH 11.5. Furthermore, this enzyme has an appreciable activity at more than pH 7.0 (7.0 < pH ≤ 11.5) with maximum activity at pH 9.0. The maximal values of k cat and k cat /K m at pH 9.0 are 3.7 × 10 6  s -1 and 5.5 × 10 7  M -1  s -1 , respectively. However, this enzyme loses its activity in the acidic pH range. We further performed 20-ns molecular dynamics simulation of CAVA to see the dynamics at different pH values. An excellent agreement was observed between in silico and in vitro studies. This study provides an insight into the activity of CAVA in the pH range of subcellular environment.

  4. Azygos Vein Dialysis Catheter Placement Using the Translumbar Approach in a Patient with Inferior Vena Cava Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaber, Mohammad R., E-mail: raffatj@msn.co; Thomson, Matthew J.; Smith, Douglas C.

    We describe percutaneous, translumbar placement of a 14-Fr dialysis catheter into an ascending lumbar vein to achieve tip position in an enlarged azygos vein. The patient had thrombosis of all traditional vascular sites, as well as the inferior vena cava. This catheter functioned well for 7 months before fatal catheter-related infection developed.

  5. Quantum Material Properties of 4d and 5d Transition Metal Oxides and Potential Applications

    DTIC Science & Technology

    2015-05-26

    11 2009): 0. doi: 10.1103/PhysRevB.80.184505 Y. Liu, I. G. Deac, P. Khalifah, R. J. Cava, Y. A. Ying, P. Schiffer , K. D. Nelson. Possible observation...Yiqun A. Ying, Karl Nelson, Iosef G. Deac, Peter Schiffer , Peter Khalifah, Robert J. Cava, and Ying Liu, "Magneto electrical transport properties and

  6. Morphology of splenocaval congenital portosystemic shunts in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2016-01-01

    To describe the anatomy of congenital portosystemic shunts involving the splenic vein communicating with the caudal vena cava at the level of the epiploic foramen. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Ninety-eight dogs and eight cats met the inclusion criteria of a congenital portosystemic shunt involving the splenic vein communicating with the prehepatic caudal vena cava plus recorded intra-operative mesenteric portovenography or computed tomography angiography and gross observations at surgery. All cases (both dogs and cats) had a highly consistent shunt that involved a distended gastrosplenic vein that communicated with the caudal vena cava at the level of the epiploic foramen via an anomalous left gastric vein. The morphology of the shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava and the subsequent development of preferential blood flow through an essentially normal portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the splenic vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.

  7. Anatomical basis of the liver hanging maneuver.

    PubMed

    Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija

    2005-01-01

    The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).

  8. Choosing Wisely: assessment of current US top five list recommendations’ trustworthiness using a pragmatic approach

    PubMed Central

    Horvath, Karl; Semlitsch, Thomas; Jeitler, Klaus; Abuzahra, Muna E; Posch, Nicole; Domke, Andreas; Siebenhofer, Andrea

    2016-01-01

    Objectives Identification of sufficiently trustworthy top 5 list recommendations from the US Choosing Wisely campaign. Setting Not applicable. Participants All top 5 list recommendations available from the American Board of Internal Medicine Foundation website. Main outcome measures/interventions Compilation of US top 5 lists and search for current German highly trustworthy (S3) guidelines. Extraction of guideline recommendations, including grade of recommendation (GoR), for suggestions comparable to top 5 list recommendations. For recommendations without guideline equivalents, the methodological quality of the top 5 list development process was assessed using criteria similar to that used to judge guidelines, and relevant meta-literature was identified in cited references. Judgement of sufficient trustworthiness of top 5 list recommendations was based either on an ‘A’ GoR of guideline equivalents or on high methodological quality and citation of relevant meta-literature. Results 412 top 5 list recommendations were identified. For 75 (18%), equivalents were found in current German S3 guidelines. 44 of these recommendations were associated with an ‘A’ GoR, or a strong recommendation based on strong evidence, and 26 had a ‘B’ or a ‘C’ GoR. No GoR was provided for 5 recommendations. 337 recommendations had no equivalent in the German S3 guidelines. The methodological quality of the development process was high and relevant meta-literature was cited for 87 top 5 list recommendations. For a further 36, either the methodological quality was high without any meta-literature citations or meta-literature citations existed but the methodological quality was lacking. For the remaining 214 recommendations, either the methodological quality was lacking and no literature was cited or the methodological quality was generally unsatisfactory. Conclusions 131 of current US top 5 list recommendations were found to be sufficiently trustworthy. For a substantial number of current US top 5 list recommendations, their trustworthiness remains unclear. Methodological requirements for developing top 5 lists are recommended. PMID:27855098

  9. Transjugular intrahepatic portosystemic shunt with accidental diagnosis of persistence of the left superior vena cava.

    PubMed

    Petridis, Ioannis; Miraglia, Roberto; Marrone, Gianluca; Gruttadauria, Salvatore; Luca, Angelo; Vizzini, Giovanni Battista; Gridelli, Bruno

    2010-03-07

    Transjugular intrahepatic portosystemic shunt (TIPSS) is considered a valid therapeutic option for the treatment of portal hypertension and its complications. The guidelines for this procedure have already been established on the basis of the normal vascular anatomy and of various technical radiological aspects. In some few rare cases, diagnosis of a congenital vascular anomaly can be made accidentally by interventional radiologists, making the procedure of the TIPSS placement extremely difficult or in some cases technically impossible. This report describes a rare vascular malformation characterized by the absence of the right superior vena cava and persistence of the left superior vena cava in a patient with a diagnosis of advanced liver cirrhosis who needed a TIPSS placement in order to control refractory ascites.

  10. [Anomalous connection of inferior vena cava to left atrium: infrequent entity that can be a diagnosis and surgical challenge].

    PubMed

    Archundia García, A; Gómez Alvarez, E; Ixcamparij Rosales, C; Blanco Canto, M; Hernández Ruiz, M A

    2000-01-01

    This is the diagnostic experiences as well as the surgical mode of treatment used in a 31 years old women suffering diversion of the inferior vena cava into the left atrium associated with atrial septal defect. The patient had been previously studied and operated thrice under conventional circumstances at different institutions in order to solve the septal defect. The hemodynamic solution had not been reached due to a missing pathological definition. The cineangiogram through the saphenous vein specified the left atrium form the inferior vena cava. Some considerations are made on the surgical methods used for the fourth operation, and in regard of the fact that the patient refused blood transfusion because of religious convictions (Jehova Witness).

  11. Modified repair of mixed anomalous pulmonary venous connection.

    PubMed

    van Son, J A; Hambsch, J; Mohr, F W

    1998-05-01

    A modified repair technique is reported for mixed total or partial anomalous pulmonary venous connection with the right superior pulmonary vein connecting to the superior vena cava, the right inferior pulmonary vein to the right atrium or left atrium, and the left pulmonary veins to the coronary sinus. The superior vena cava is transected above the highest right superior pulmonary vein, its cephalad end is anastomosed to the right atrial appendage, and a pericardial baffle is constructed between the cardiac ostium of the superior vena cava, the ostium of the right inferior pulmonary vein, and the left atrium, including the coronary sinus, which is unroofed. The reported technique may be valuable to avoid pulmonary venous obstruction in complex mixed forms of total or partial anomalous pulmonary venous connection.

  12. Bard Denali inferior vena cava filter fracture and embolization resulting in cardiac tamponade: a device failure analysis.

    PubMed

    Kuo, William T; Robertson, Scott W

    2015-01-01

    A 46-year-old woman underwent inferior vena cava filter placement before bariatric surgery and returned within 6 months for routine removal. She complained of a 1-week history of severe chest pain, and during retrieval, two fractured filter components were identified including one arm in the right ventricle. The filter body and one fragment were successfully retrieved, but the fragment in the right ventricle was refractory to percutaneous retrieval. During open-heart surgery, the fragment was found traversing through the ventricular wall resulting in cardiac tamponade. Electron microscopic fragment analysis revealed high-cycle metal fatigue indicating the filter design failed to withstand this patient's natural inferior vena cava biomechanical motions. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  13. Beef customer satisfaction: trained sensory panel ratings and Warner-Bratzler shear force values.

    PubMed

    Lorenzen, C L; Miller, R K; Taylors, J F; Neely, T R; Tatum, J D; Wise, J W; Buyek, M J; Reagan, J O; Savell, J W

    2003-01-01

    Trained sensory panel ratings and Warner-Bratzler shear force (WBS) values from the Beef Customer Satisfaction study are reported. Carcasses were chosen to fit into USDA quality grades of Top Choice (upper two-thirds of USDA Choice), Low Choice, High Select, and Low Select. A trained, descriptive attribute panel evaluated top loin, top sirloin, and top round steaks for muscle fiber tenderness, connective tissue amount, overall tenderness, juiciness, flavor intensity, cooked beef flavor intensity, and cooked beef fat flavor intensity. Four steaks from each of the three cuts from each carcass were assigned randomly to one of four cooking endpoint temperature treatments (60, 65, 70, or 75 degrees C) for WBS determination. For all trained panel measures of tenderness and WBS, regardless of USDA quality grade, top loin steaks were rated higher than top sirloin steaks, which were rated higher than top round steaks (P < 0.05). There were significant interactions between USDA quality grade and cut for most of the trained sensory panel traits: USDA quality grade influenced ratings for top loin steaks more than ratings for top round steaks or top sirloin steaks. Three interactions were significant for WBS values: USDA quality grade x endpoint temperature (P = 0.02), USDA quality grade x cut (P = 0.0007), and cut x endpoint temperature (P = 0.0001). With the exception of High Select, WBS values increased (P < 0.05) for each grade with increasing endpoint temperature. Choice top loin and top round steaks had lower (P < 0.05) WBS values than Select steaks of the same cut; however, only Top Choice top sirloin steaks differed (P < 0.05) from the other USDA grades. As endpoint temperatures increased, WBS values for top sirloin steaks increased substantially compared to the other cuts. When cooked to 60 degrees C, top sirloin steaks were closer to top loin steaks in WBS values, when cooked to 75 degrees C, top sirloin steaks were closer to top round steaks in WBS values. Simple correlation coefficients between consumer ratings and trained sensory muscle fiber tenderness, connective tissue amount, overall tenderness, juiciness, flavor intensity, and cooked beef fat flavor were significant (P < 0.05), but values were low. While relationships exist between consumer and trained sensory measures, it is difficult to predict from objective data how consumers will rate meat at home.

  14. Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound

    DTIC Science & Technology

    2017-10-01

    AWARD NUMBER: W81XWH-15-1-0709 TITLE: Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound PRINCIPAL INVESTIGATOR: Donald...No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for... information . Send comments regarding this burden estimate or any other aspect of this collection of information , including suggestions for reducing this

  15. Nephroblastoma with right atrial extension: preoperative diagnosis and management.

    PubMed

    Vaughan, E D; Crosby, I K; Tegtmeyer, C J

    1977-04-01

    A 14-year-old black boy, with a large nephroblastoma of the right kidney, had preoperative identification of inferior vena cava and right atrial involvement. Renal arteriography revealed linear arterial channels in the anatomic distribution of the inferior vena cava and venography revealed total caval occlusion and a right atrial mass. Radical excision, using a cardiopulmonary bypass, resulted in a 6-month postoperative survival.

  16. Bilateral Breast Enlargement: An Unusual Presentation of Superior Vena Cava Obstruction in a Hemodialysis Patient with Fibrosing Mediastinitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goo, Dong Erk, E-mail: degoo@hosp.sch.ac.kr; Kim, Yong Jae; Choi, Deuk Lin

    2011-02-15

    A 67-year-old woman with end-stage renal disease presented with profound edema of both breasts. The presence of a patent hemodialysis basilic transposition fistula and superior vena cava obstruction (SVC), due to fibrosing mediastinitis, was demonstrated by the use of fistulography. Endovascular treatment with a balloon and stent caused immediate resolution of the breast edema.

  17. Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.

    2004-01-15

    We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.

  18. Procedural and Indwelling Complications with Inferior Vena Cava Filters: Frequency, Etiology, and Management

    PubMed Central

    Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran

    2015-01-01

    Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846

  19. Neuroprotective effects of vinpocetine and its major metabolite cis-apovincaminic acid on NMDA-induced neurotoxicity in a rat entorhinal cortex lesion model.

    PubMed

    Nyakas, Csaba; Felszeghy, Klára; Szabó, Róbert; Keijser, Jan N; Luiten, Paul G M; Szombathelyi, Zsolt; Tihanyi, Károly

    2009-01-01

    Vinpocetine (ethyl-apovincaminate, Cavinton), a synthetic derivative of the Vinca minor alkaloid vincamine, has been used now for decades for prevention and treatment of cerebrovascular diseases predisposing to development of dementia. Both vinpocetine and its main metabolite cis-apovincaminic acid (cAVA) exert a neuroprotective type of action. Bilateral N-methyl-D-aspartate (NMDA)-induced neurodegeneration in the entorhinal cortex of rat was used as a dementia model to confirm the neuroprotective action of these compounds in vivo. NMDA-lesioned rats were treated 60 min before lesion and throughout 3 postoperative days with a 10 mg/kg intraperitoneal dose of vinpocetine or cAVA. Behavioral tests started after termination of drug treatment and consisted of novel object recognition, social discrimination, and spontaneous alternation in a Y-maze, and spatial learning in the Morris water maze. At the end of behavioral testing brains were perfused with fixative and the size of the excitotoxic neuronal lesion and that of microglial activation around the lesion were assayed quantitatively on brain sections immunostained for neuron-specific nuclear protein (NeuN) and integrin CD11b, respectively. Entorhinal NMDA lesions impaired recognition of novel objects and the new social partner, and suppressed spontaneous alternation and spatial learning performance in the Morris maze. Both vinpocetine and cAVA effectively attenuated the behavioral deficits, and significantly decreased lesion size and the region of microglia activation. Both lesion-induced attention deficit and learning disabilities were markedly alleviated by vinpocetine and cAVA. The morphological findings corroborated the behavioral observations and indicated reduced lesion size and microglia activation especially after vinpocetine treatment which supports an in vivo neuroprotective mode of action of vinpocitine and a less potent action of cAVA.

  20. Inferior Vena Cava Filters in Elderly Patients with Stable Acute Pulmonary Embolism.

    PubMed

    Stein, Paul D; Matta, Fadi; Hughes, Mary J

    2017-03-01

    Patients aged >60 years with pulmonary embolism who were stable and did not require thrombolytic therapy were shown to have a somewhat lower in-hospital all-cause mortality with vena cava filters. In this investigation we further assess mortality with filters in stable elderly patients. In-hospital all-cause mortality according to use of inferior vena cava filters was assessed from the National (Nationwide) Inpatient Sample, 2003-2012, in: 1) All patients with pulmonary embolism; 2) All with pulmonary embolism who had none of the comorbid conditions listed in the Charlson Comorbidity Index; 3) Patients with a primary (first-listed) diagnosis of pulmonary embolism, and 4) Patients with a primary diagnosis of pulmonary embolism and none of the comorbid conditions listed in the Charlson Comorbidity Index. From 2003-2012, 2,621,575 stable patients with pulmonary embolism were hospitalized in the US. Patients aged >80 years showed lower mortality with vena cava filters (all pulmonary embolism, 6.1% vs 10.5%; all pulmonary embolism with no comorbid conditions, 3.3% vs 6.3%; primary pulmonary embolism, 4.1% vs 5.7%; primary pulmonary embolism with no comorbid conditions, 2.1% vs 3.7%; all P <.0001). In the all-patient category, patients aged 71-80 years showed somewhat lower mortality with filters, 6.3% vs 7.4% (P <.0001), and those without comorbid conditions, 2.5% vs 2.8% (P = .04). Those aged 71-80 years with primary pulmonary embolism, irrespective of comorbid conditions, did not show lower mortality with filters. At present, in the absence of a randomized controlled trial, it seems prudent to consider a vena cava filter in very elderly (aged >80 years) stable patients with acute pulmonary embolism. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Modeling Flow Past a Tilted Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Wang, S L

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside amore » model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.« less

  2. Changes in Plasma Progesterone Levels in the Caudal Vena Cava and the Jugular Vein and Luteinizing Hormone Secretion Pattern After Feeding in Lactating and Non-lactating Dairy Cows

    PubMed Central

    ENDO, Natsumi; NAGAI, Kiyosuke; TANAKA, Tomomi; KAMOMAE, Hideo

    2012-01-01

    Abstract The present study was designed to assess progesterone profiles at the secreted (caudal vena cava) and circulating levels (jugular vein) and luteinizing hormone (LH) secretion pattern in lactating and non-lactating cows with reference to feeding. Four lactating and four non-lactating cycling Holstein cows were examined. Blood samples were collected simultaneously from the caudal vena cava (via a catheter inserted from the coccygeal vein) and the jugular vein every 15 min for 12 h (0500–1700 h) during the functional luteal phase. Cows were fed 50% of the daily diet 6 h after the start of blood sampling. During the 12-h sampling period, mean progesterone concentrations in the caudal vena cava did not differ between lactating and non-lactating cows (49.0 ± 2.9 and 53.3 ± 3.7 ng/ml; mean ± SE), whereas mean progesterone concentrations in the jugular vein in lactating cows were higher than those in non-lactating cows (6.4 ± 0.1 and 5.6 ± 0.1 ng/ml, P < 0.001). Lactating cows had a higher frequency of LH pulses than non-lactating cows (7.0 ± 0.7 and 4.3 ± 0.9 pulses/12 h, P<0.05). The influence of feeding was not observed on LH profiles but was observed on progesterone profiles in both veins. Progesterone concentrations in the caudal vena cava increased after feeding in both groups. Progesterone concentrations in the jugular vein decreased after feeding in lactating cows but not in non-lactating cows. These results indicate the difference in feeding-related changes in progesterone dynamics between lactating and non-lactating cows. PMID:23171608

  3. A case of residual inferior sinus venosus defect after ineffective surgical closure.

    PubMed

    Uga, Sayuri; Hidaka, Takayuki; Takasaki, Taiichi; Kihara, Yasuki

    2014-10-03

    A 38-year-old woman presented with cyanosis and heart failure 34 years after patch closure of an atrial septal defect and partial anomalous pulmonary venous connection. CT and cardiac catheterisation showed a residual defect that caused right-to-left shunting. The patch almost blocked the inferior vena cava from the right atrium, resulting in uncommon drainage of the inferior vena cava into the left atrium. Other anomalies included the coronary-to-pulmonary artery fistula and duplicate inferior vena cava with dilated azygos venous system. A second surgery was performed, and we confirmed an inferior sinus venosus defect, which is rare and can be misdiagnosed. The ineffective patch closure had caused a haemodynamic status that rarely occurs. We describe the diagnostic process and emphasise the importance of correctly understanding the entity. 2014 BMJ Publishing Group Ltd.

  4. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less

  5. Meandering Right Pulmonary Vein to the Left Atrium and Inferior Vena Cava

    PubMed Central

    Tortoriello, Tia A.; Vick, G. Wesley; Chung, Taylor; Bezold, Louis I.; Vincent, Julie A.

    2002-01-01

    We report a case of a healthy, asymptomatic 6-year-old boy in whom an anomalous right pulmonary vein was noted to drain into both the inferior vena cava and left atrium in association with findings consistent with scimitar syndrome. The anomalous pulmonary vein took a very circuitous route through the lungs before draining into the left atrium, a condition previously termed “meandering pulmonary vein.” To aid in the diagnosis, cardiovascular magnetic resonance imaging and magnetic resonance angiography were used to delineate this complex course and the connection of the anomalous pulmonary vein. To our knowledge, this is the 1st reported case of a meandering pulmonary vein with dual drainage to the inferior vena cava and left atrium in association with other anomalies. (Tex Heart Inst J 2002;29:319–23) PMID:12484618

  6. Superior vena cava syndrome with central venous catheter for chemotherapy treated successfully with fibrinolysis.

    PubMed

    Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R

    2007-03-01

    Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.

  7. Blood Oxygen Conservation in Diving Sea Lions: How Low Does Oxygen Really Go

    DTIC Science & Technology

    2015-09-30

    5 6 7 0 20 40 60 80 100 % H b Sa tu ra tio n (S O2 ) Time into Dive (min) Arterial SO2 PostVenaCava SO2 AntVenaCava SO2 3 Figure 2. Rate of...change in posterior venacaval hemoglobin saturation ( SO2 ) in relation to stroke rate during descent, bottom phase, and ascent of all dives of sea

  8. Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dursun, Memduh, E-mail: memduhdursun@yahoo.com; Sarvar, Sadik; Cekrezi, Bledi

    2008-07-15

    Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.

  9. Venous outflow obstruction and portopulmonary hypertension after orthotopic liver transplantation

    PubMed Central

    Aguirre-Avalos, Guadalupe; Covarrubias-Velasco, Marco Antonio; Rojas-Sánchez, Antonio Gerardo

    2013-01-01

    Patient: Female, 54 Final Diagnosis: Suprahepatic inferior vena cava anastomosis stricture Symptoms: Ascites • fatigue • lower limb edema • hepatomegaly Medication: — Clinical Procedure: — Specialty: Transplantology • Critical Care Medicine Objective: Unusual clinical course Background: Suprahepatic inferior vena cava anastomosis stricture is an unusual vascular complication after orthotopic liver transplantation with the “piggyback” technique. Clinical manifestations are dependent upon the severity of the stenosis. Portopulmonary hypertension after orthotopic liver transplantation is a complication that carries high mortality due to cardiopulmonary dysfunction. The pathogenesis of pulmonary vascular disorders after orthotopic liver transplantation remains uncertain. Case Report: We report a case of acute right heart pressure overload after surgical correction of the suprahepatic inferior vena cava anastomotic stricture in a 54-year-old woman who had preexisting pulmonary arterial hypertension associated with portal hypertension after orthotopic liver transplantation. Twenty months posttransplantation, she developed fatigue and progressive ascites. On admission, the patient had hepatomegaly, ascites, and lower limb edema. Symptoms in the patient developed gradually over time. Conclusions: Recurrent portal hypertension by vascular complications is a cause of pulmonary arterial hypertension after orthotopic liver transplantation. Clinical manifestations of suprahepatic inferior vena cava anastomotic stenosis are dependent upon their severity. Sildenafil is an effective drug for treatment of pulmonary arterial hyper-tension after portal hypertension by vascular complications. PMID:24046802

  10. [The assessment of ultrasonic measurement of superior vena cava blood flow for the volume responsiveness of patients with mechanical ventilation].

    PubMed

    Guo, Zhe; He, Wei; Hou, Jing; Li, Tong; Zhou, Hua; Xu, Yuan; Xi, Xiuming

    2014-09-01

    To approach the evaluative effect of respiratory variation of superior vena cava peak flow velocity measured using transthoracic echocardiography (TTE) on fluid responsiveness in patients with mechanical ventilation. A prospective cohort study was conducted. All mechanical ventilated critically ill patients whose fluid therapy was planned due to hypovolemia in Department of Critical Care Medicine of Beijing Tongren Hospital of Capital Medical University from April 2011 to April 2013 were enrolled. Volume expansion was performed with 500 mL Linger solution within 30 minutes. Patients were classified as responders if pulse pressure variation (PPV) increased ≥ 13% before volume expansion. The respiratory variation in superior vena cava peak velocity was calculated as the difference between maximum and minimum values of velocity in peak A, peak S and peak D over a single respiratory circle, and their variations (ΔA, ΔS, ΔD) were also calculated. The receiver operating characteristic curve (ROC curve) was plotted to assess the evaluative effect of respiratory variation of superior vena cava peak velocity on fluid responsiveness. Twenty-seven patients were enrolled in this study. Volume expansion increased PPV ≥ 13% happened in 14 patients (responders). The velocity of superior vena cava in peak A, peak S, peak D was significantly increased after volume expansion compared with that before volume expansion in responders [peak A (cm/s): 34.6 ± 2.2 vs. 31.3 ± 2.1, t=-2.493, P=0.027; peak S (cm/s): 39.1 ± 1.3 vs. 35.3 ± 2.1, t=-2.564, P=0.024; peak D (cm/s): 28.1 ± 1.2 vs. 23.3 ± 1.4, t=-4.995, P=0.000], but there was no significant difference in ΔA, ΔS and ΔD between before and after volume expansion. The ΔA, ΔS and ΔD were positively correlated with PPV (r=0.040, P=0.854; r=0.350, P=0.074; r=0.749, P=0.000). The area under ROC curve (AUC) of peak S was 0.36 [95% confidence interval (95%CI): 0.11-0.52], but the AUC of ΔS was 0.68 (95%CI 0.47-0.89), the AUC of peak D was 0.41 (95%CI 0.19-0.63), but the AUC of ΔD was 0.95 (95%CI 0.86-1.00), so the aberration rate of superior vena cava in respiration was better than the flow rate in superior vena cava. When the cut-off value of ΔS was 20.7% for predicting fluid responsiveness, the sensitivity was 78.6% and the specificity was 61.5%. When the cut-off value of ΔD was 12.7% for predicting fluid responsiveness, the sensitivity was 92.0% and the specificity was 92.3%. Respiratory variations in superior vena cava peak velocity measured by TTE could assess fluid responsiveness in patients with mechanical ventilation.

  11. Characterization and Utilization of Opiate-Like Hibernation Factors.

    DTIC Science & Technology

    1993-12-08

    duodenum, and both kidneys were dissected free, along with the abdominal aorta and the inferior vena cava . The chest was then opened, and the heart, and...lungs along with the aorta and the superior and inferior vena cava (IVC), were dissected free. The trachea was transected and an endotracheal tube was...pericardial incision was extended inferiorly, exposing the anterior aspect of the left atrium and the left -Page 36 - inferior pulmonary vein. The

  12. Radiofrequency Guide Wire Recanalization of Venous Occlusions in Patients with Malignant Superior Vena Cava Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.

    Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.

  13. Development of a rapid and sensitive HPLC method for the identification and quantification of cavoxin and cavoxone in Phoma cava culture filtrates.

    PubMed

    Masi, Marco; Moeini, Seyed Arash; Boari, Angela; Cimmino, Alessio; Vurro, Maurizio; Evidente, Antonio

    2018-07-01

    Cavoxin is a tetrasubstituted phytotoxic chalcone and cavoxone is the corresponding chroman-4-one, both produced in vitro by Phoma cava, a fungus isolated from chestnut. Cavoxin showed biofungicide potential against fungal species responsible for food moulding. Therefore, cavoxin has potential to be incorporated into biopolymer to generate 'intelligent food packaging'. To reach this objective, large-scale production of cavoxin by P. cava fermentation needs to be optimized. A rapid and efficient method for cavoxin analysis, as well as of cavoxone, in the fungal culture filtrates and the corresponding organic extracts is the first experimental step. Thus, a HPLC method was developed and applied to quantify cavoxin and cavoxone production in two different fungal culture conditions. The analysis proved that cavoxin production in stirred culture filtrates is significantly higher than in static ones.

  14. Situs ambiguous in a schoolchild

    PubMed Central

    Tortajada, Miguel; Moreno, Miriam; Gracia, Miguel; Sanchis, Amparo

    2010-01-01

    We report the case of a 9-year-old child with asthma, atopic dermatitis and allergic rhinoconjunctivitis due to house dust mites, in whom a routine chest x-ray identified by chance abnormal organ position, such as the stomach located on the right side. Abdominal ultrasonography indicated a centralised liver, with polysplenia on the right side and an inferior cava vein located to the left of the aorta with no interruption. Ultrasonography did not show heart defects. Magnetic resonance imaging (MRI) of the abdomen was performed that showed a short pancreas, with no neck, body and tail in it, and a left inferior vena cava with normal outlet of the renal veins, and absence of the intrahepatic part of the inferior vena cava, that was replaced by the left hemiazygos vein. Spinal cord MRI revealed dorsal syringomelia. In view of the results obtained, the diagnosis of situs ambiguous was established. PMID:22121394

  15. Antiphospholipid Antibody Syndrome Associated with Graves’ Disease Presenting As Inferior Vena Cava Thrombosis with Bilateral Lower Limb DVT

    PubMed Central

    Jain, Ankur

    2014-01-01

    We report a case of a 60-year-old lady who presented with bilateral lower limb swelling and a thyroid swelling with clinical features consistent with thyrotoxicosis. Investigations revealed the presence of a thrombus in bilateral external, internal iliac veins, and inferior vena cava extending up to its infrahepatic part. Hormone profile and radioiodine uptake scan confirmed the diagnosis of Graves’ disease. Further workup revealed the presence of antiphospholipid antibodies (confirmed after a repeat test at 12 weeks). The patient was treated with antithyroid drugs and anticoagulants. The patient improved with normalization of thyroid function and partial recanalization of the infrahepatic part of inferior vena cava. Hyperthyroidism has been implicated as a potential hypercoagulable state; however, the association of Graves’ disease with antiphospholipid antibody syndrome is limited to isolated case reports. This case highlights a new mechanism underlying hypercoagulability associated with Graves’ disease. PMID:24812529

  16. Osteodiskitis of Lumbar Spine Due to Migrated Fractured Inferior Vena Cava Filter.

    PubMed

    Aoun, Salah G; Bedros, Nicole; El Ahmadieh, Tarek Y; Kreck, Jake; Mehta, Nikhil; Al Tamimi, Mazin

    2018-05-01

    Venous thromboembolism can be a significant cause of morbidity in the trauma population. Medical and surgical specialties have been pushing the indication for prophylactic filter placement. A 36-year-old man presented with axial lower back pain with a radicular right L2 component after lifting a heavy object. He had a history of penetrating brain trauma 3 years prior, with placement of a prophylactic inferior vena cava filter. His radiograph, computed tomography, and magnetic resonance imaging of the lumbar spine showed fracture of his filter, with migration of the fractured fragment through the inferior vena cava and into the L2-L3 disk space, and surrounding bony lysis and severe osteodiskitis. He was treated medically with intravenous and then oral antibiotics and improved clinically and radiographically. Conservative use of filter devices and early retrieval once their indication expires are paramount to avoid unnecessary complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Persistent left superior vena cava

    PubMed Central

    Tyrak, Kamil W; Hołda, Mateusz K; Koziej, Mateusz; Piątek, Katarzyna; Klimek-Piotrowska, Wiesława

    2017-01-01

    Summary Persistent left superior vena cava (PLSVC) is the most common congenital malformation of thoracic venous return and is present in 0.3 to 0.5% of individuals in the general population. This heart specimen was dissected from a 35-yearold male cadaver whose cause of death was determined as non-cardiac. The heart was examined and we found a PLSVC draining into the coronary sinus. The right superior vena cava was present with a small-diameter ostium. An anomalous pulmonary vein pattern was observed; there was a common trunk to the left superior and left inferior pulmonary veins (diameter 17.8 mm) and an additional middle right pulmonary vein (diameter 2.7 mm) with two classic right pulmonary veins. The PLSVC draining into the coronary sinus had led to its enlargement, which could have altered the cardiac haemodynamics by significantly reducing the size of the left atrium and impeding its outflow via the mitral valve. PMID:28759082

  18. Double aortic arch and persistent left vena cava in a white lion cub (Panthera leo).

    PubMed

    Goldin, J P; Lambrechts, N E

    1999-03-01

    A 4-mo-old female white lion (Panthera leo) cub was presented with a 2-wk history of persistent postprandial regurgitation, mild dyspnea, and poor weight gain. The cub was weak and thin but otherwise alert. Survey and contrast radiography revealed a large dilated esophagus cranial to the heart base, with an esophageal filling defect present at the level of the fourth thoracic vertebra. A vascular ring anomaly was tentatively diagnosed. Exploratory thoracotomy revealed a double aortic arch and a persistent left vena cava. The left aortic arch was ligated and divided, and recovery was uneventful. A single episode of regurgitation occurred within the first postoperative month, and the cub gained 5.5 kg in weight during the same time period. Neither double aortic arch nor persistent left vena cava has been reported in a nondomestic felid.

  19. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology.

    PubMed

    Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K

    2015-04-01

    To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  20. [Surgical treatment of partial anomalous pulmonary venous drainage].

    PubMed

    Cabrera, A; Idígoras, G; Sarrionandía, M J; Martínez, P; Rumoroso, J R; Alcíbar, J

    1996-02-01

    We studied all patients operated for partial anomalous pulmonary venous drainage and half-time follow-up. Twenty-eight patients with a mean age of 5 +/- 5 years (5 patients were less than 1 year old). There were sixteen male and twelve female patients. Thirteen patients were symptomatic (47%). The drainage was to the superior vena cava in thirteen cases, to the inferior vena cava in eight cases, to the right atrium in five cases, mixed (to the superior vena cava and to the inferior vena cava) in one case and to the innominate vein in one patient. The diagnosis was made through echocardiography and catheterization in 25 patients, whereas nuclear magnetic resonance was performed in the last five patients. All cases were corrected through medium thoracotomy, except for the single case in which the drainage was to the innominate vein). In 27 patients, the pulmonary veins were guided to the left atrium through an enlarged present atrial septal defect or through a created atrial septal defect. In one case a direct connection was performed from the veins to the left atrium. After the surgical correction, all patients underwent a color-coded Doppler echocardiography study and a nuclear magnetic resonance study was performed in five patients. Twenty-seven patients survived after surgical correction. The patient with a mixed drainage developed an obstruction of the superior vena cava, the pressure gradient was 9 mmHg. He required a second surgical procedure followed with angioplasty on two occasions during a six month period. Two patients showed an ectopic atrial rhythm at some late time. The patient who died was one month old and had an associated pulmonary parenchymal sequestration. Partial anomalous venous connection is a congenital heart disease which has an easy surgical correction. Complications may arise after the surgical correction, among them obstruction of the superior vena cava and arrythmias are most frequently found. Obstruction is present when 50% of the caval area is occupied by the patch. The arrythmias occur following all surgical techniques. In order to decrease the arrythmias it is necessary to perform a good hemosthasis at the site of the patch, to leave the sinus node free of compression and to perform the atrial incision at the posterior wall. The diagnosis and the follow-up can be performed with non-invasive procedures.

  1. A tethering system for direct measurement of cardiovascular function in the caged baboon

    NASA Technical Reports Server (NTRS)

    Byrd, L. D.

    1979-01-01

    A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

  2. [Value of x-ray computed tomography in the study of the inferior vena cava in urologic practice].

    PubMed

    Barré, C; Vialle, M; Rieux, D; Caron-Poitreau, C; Soret, J Y; Rognon, M

    1985-01-01

    The CT scan provides a reliable evaluation of the inferior vena cava, especially since the development of second and third generation scanners. It can readily detect congenital malformations and obstructive anomalies complicating renal cancer and it is also able to determine the tumoral or thrombotic nature of the venous obstruction. This excellent definition of the vessel reduces the indications for caval angiography to a few exceptional cases.

  3. Cardiac Pressure Changes with Venous Gas Embolism and Decompression

    DTIC Science & Technology

    1994-04-01

    inferior vena cava via the left femoral vein for venous access. Airway pressure was measured from a connector at the proximal end of the endotracheal...Hartley), mount- ed in a 7-9 m acrylic cuff was surgically placed around the inferior vena cava via laparotomy, approximately 1-2 cm above the renal...pressure and decreasing cardiac output which in return may cause the left atrial pressure to fall below that of the right atrium . Recent studies have

  4. Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact

    DTIC Science & Technology

    2001-03-01

    inferior vena cava to the right auricle. From the right auricle, the blood is passed into the right ventricle. The right ventricle pumps the blood...the rib and vertebrae is modeled with two beam elements. To create the subcoastal angle, vertical cartilaginous connections at the inferior edge of...brachiocephalic aorta, the aorta, pulmonary arteries and veins, internal jugular veins, brachial veins, and superior vena cava . These vessels are modeled

  5. Permanent right ventricular pacing through an anomalous left superior vena cava.

    PubMed Central

    Amikam, S; Lemer, J; Riss, E

    1977-01-01

    A persistent left superior vena cava can complicate the implantation of a transvenous pacemaker. In a patient who required a permanent pacemaker, this venous anomaly was discovered during the insertion of the electrode but it did not prevent long-term right ventricular pacing. This was achieved after the electrode had been manipulated through the coronary sinus and right atrium. A plan of management is proposed for dealing with this unexpected problem. Images PMID:601745

  6. Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.

    PubMed

    Hoffer, Eric K; Mueller, Rebecca J; Luciano, Marcus R; Lee, Nicole N; Michaels, Anne T; Gemery, John M

    2013-08-01

    To evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter. A retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59% were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86% of patients; 14% were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records. Mean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3%). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4%). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8%) at a mean of 731 days revealed a single (0.3%) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5%), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4%) at a mean 757 days. The Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

  7. Morphology of congenital portosystemic shunts involving the right gastric vein in dogs.

    PubMed

    White, R N; Parry, A T

    2015-07-01

    To describe the anatomy of congenital portosystemic shunts involving the right gastric vein in dogs. Retrospective review of a consecutive series of dogs managed for congenital portosystemic shunt. Twenty-two dogs met the inclusion criteria of a congenital portosystemic shunt involving the right gastric vein with recorded intraoperative mesenteric portovenography or computed tomography angiography and gross observations at the time of surgery. Of these, 20 (91%) had a shunt that entered the pre-hepatic caudal vena cava at the level of the epiploic foramen and two (9%) had a shunt that entered the post-hepatic caudal vena cava at the level of the diaphragm. Shunts entering the pre-hepatic caudal vena cava could be further classified into three consistent subdivisions. The morphology of each shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava, the presence or absence of an abnormal communication between the splenic, left gastric and portal veins and the subsequent development of preferential blood flow through essentially normal portal vessels within the portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the right gastric vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.

  8. Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.org; Mueller, Rebecca J.; Luciano, Marcus R.

    PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinicalmore » follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.« less

  9. Surgical management of anomalous pulmonary venous connection to the superior vena cava - early results

    PubMed Central

    Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.

    2013-01-01

    Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880

  10. Improving Image Quality of Coronary Computed Tomography Angiography Using Patient Weight and Height-Dependent Scan Trigger Threshold.

    PubMed

    Kang, Deqiang; Hua, Haiqin; Peng, Nan; Zhao, Jing; Wang, Zhiqun

    2017-04-01

    We aim to improve the image quality of coronary computed tomography angiography (CCTA) by using personalized weight and height-dependent scan trigger threshold. This study was divided into two parts. First, we performed and analyzed the 100 scheduled CCTA data, which were acquired by using body mass index-dependent Smart Prep sequence (trigger threshold ranged from 80 Hu to 250 Hu based on body mass index). By identifying the cases of high quality image, a linear regression equation was established to determine the correlation among the Smart Prep threshold, height, and body weight. Furthermore, a quick search table was generated for weight and height-dependent Smart Prep threshold in CCTA scan. Second, to evaluate the effectiveness of the new individual threshold method, an additional 100 consecutive patients were divided into two groups: individualized group (n = 50) with weight and height-dependent threshold and control group (n = 50) with the conventional constant threshold of 150 HU. Image quality was compared between the two groups by measuring the enhancement in coronary artery, aorta, left and right ventricle, and inferior vena cava. By visual inspection, image quality scores were performed to compare between the two groups. Regression equation between Smart Prep threshold (K, Hu), height (H, cm), and body weight (BW, kg) was K = 0.811 × H + 1.917 × BW - 99.341. When compared to the control group, the individualized group presented an average overall increase of 12.30% in enhancement in left main coronary artery, 12.94% in proximal right coronary artery, and 10.6% in aorta. Correspondingly, the contrast-to-noise ratios increased by 26.03%, 27.08%, and 23.17%, respectively, and by 633.1% in contrast between aorta and left ventricle. Meanwhile, the individualized group showed an average overall decrease of 22.7% in enhancement of right ventricle and 32.7% in inferior vena cava. There was no significant difference of the image noise between the two groups (P > .05). By visual inspection, the image quality score of the individualized group was higher than that of the control group. Using personalized weight and height-dependent Smart Prep threshold to adjust scan trigger time can significantly improve the image quality of CCTA. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Pharmacological endothelin receptor interaction does not occur in veins from ET(B) receptor deficient rats.

    PubMed

    Thakali, Keshari; Galligan, James J; Fink, Gregory D; Gariepy, Cheryl E; Watts, Stephanie W

    2008-07-01

    Heterodimerization of G-protein coupled receptors can alter receptor pharmacology. ET A and ET B receptors heterodimerize when co-expressed in heterologous expression lines. We hypothesized that ET A and ET B receptors heterodimerize and pharmacologically interact in vena cava from wild-type (WT) but not ET B receptor deficient (sl/sl) rats. Pharmacological endothelin receptor interaction was assessed by comparing ET-1-induced contraction in rings of rat thoracic aorta and thoracic vena cava from male Sprague Dawley rats under control conditions, ET A receptor blockade (atrasentan, 10 nM), ET B receptor blockade (BQ-788, 100 nM) or ET B receptor desensitization (Sarafotoxin 6c, 100 nM) and ET A plus ET B receptor blockade or ET A receptor blockade plus ET B receptor desensitization. In addition, similar pharmacological ET receptor antagonism experiments were performed in rat thoracic aorta and vena cava from WT and sl/sl rats. ET A but not ET B receptor blockade or ET B receptor desensitization inhibited aortic and venous ET-1-induced contraction. In vena cava but not aorta, when ET B receptors were blocked (BQ-788, 100 nM) or desensitized (S6c, 100 nM), atrasentan caused a greater inhibition of ET-1-induced contraction. Vena cava from WT but not sl/sl rats exhibited similar pharmacological ET receptor interaction. Immunocytochemistry was performed on freshly dissociated aortic and venous vascular smooth muscle cells to determine localization of ET A and ET B receptors. ET A and ET B receptors qualitatively co-localized more strongly to the plasma membrane of aortic compared to venous vascular smooth muscle cells. Our data suggest that pharmacological ET A and ET B receptor interaction may be dependent on the presence of functional ET B receptors and independent of receptor location.

  12. Patterns of anomalous pulmonary venous drainage.

    PubMed

    Snellen, H A; van Ingen, H C; Hoefsmit, E C

    1968-07-01

    All of our cases of abnormal pulmonary venous connections collected to the middle of 1965 and verified at surgery or autopsy have been reviewed by means of diagrams and tabulations, using a specially devised code to facilitate the survey. The material consisted of 52 autopsy cases (half of them obtained after surgery) and the cases of 72 patients who survived operation. The postmortem group was much younger than the surgical group and differed also from the latter by showing male preponderance as well as relatively many instances of total abnormal pulmonary venous connection and frequently associated cardiac anomalies. Partial anomalous connection of right pulmonary veins was 10 times more frequent than that of the left pulmonary veins. This was caused by (1) the frequent drainage of some of the right pulmonary veins into the junctional area between right atrium and superior vena cava in the presence of normal left pulmonary veins, and (2) the complete absence of isolated left pulmonary venous connection to the right atrium. Abnormal connection of solitary pulmonary veins was always effected to the most proximal venous structure among the four possible ones which are derived from the main embryonic channels (superior vena cava and inferior vena cava on the right side, and left superior vena cava and coronary sinus on the left side). Common pulmonary veins from one lung also drained in accordance with this proximity rule, if this may be taken to apply also to the drainage of right pulmonary veins into the right atrium. The one exception in our material was the drainage of all right pulmonary veins into the portal venous system. Total abnormal pulmonary venous connection may be found with all structures mentioned, but most frequently with the left superior vena cava, or coronary sinus, or both, usually by way of a common pulmonary vein. In a few cases however, drainage into different sites, all of them abnormal, did occur. Then again the proximity rule seemed to apply. A tentative embryological explanation is given for the patterns described.

  13. An uncommon and insidious presentation of renal cell carcinoma with tumor extending into the inferior vena cava and right atrium: a case report.

    PubMed

    Lu, Hou Tee; Chong, Jen Lim; Othman, Norliza; Vendargon, Simon; Omar, Shamsuddin

    2016-05-03

    Renal cell carcinoma is a potentially lethal cancer with aggressive behavior and it tends to metastasize. Renal cell carcinoma involves the inferior vena cava in approximately 15% of cases and it rarely extends into the right atrium. A majority of renal cell carcinoma are detected as incidental findings on imaging studies obtained for unrelated reasons. At presentation, nearly 25% of patients either have distant metastases or significant local-regional disease with no symptoms that can be attributed to renal cell carcinoma. A 64-year-old Indian male with a past history of coronary artery bypass graft surgery, congestive heart failure, and diabetes mellitus complained of worsening shortness of breath for 2 weeks. Incidentally, a transthoracic echocardiography showed a "thumb-like" mass in his right atrium extending into his right ventricle through the tricuspid valve with each systole. Abdomen magnetic resonance imaging revealed a heterogenous lobulated mass in the upper and mid-pole of his right kidney with a tumor extending into his inferior vena cava and right atrium, consistent with our diagnosis of advanced renal cell carcinoma which was later confirmed by surgical excision and histology. Radical right nephrectomy, lymph nodes clearance, inferior vena cava cavatomy, and complete tumor thrombectomy were performed successfully. Perioperatively, he did not require cardiopulmonary bypass or deep hypothermic circulatory arrest. He had no recurrence during the follow-up period for more than 2 years after surgery. Advanced extension of renal cell carcinoma can occur with no apparent symptoms and be detected incidentally. In rare circumstances, atypical presentation of renal cell carcinoma should be considered in a patient presenting with right atrial mass detected by echocardiography. Renal cell carcinoma with inferior vena cava and right atrium extension is a complex surgical challenge, but excellent results can be obtained with proper patient selection, meticulous surgical techniques, and close perioperative patient care.

  14. Forging Institutional Links: Making Quality Circles Work in the U.S.

    ERIC Educational Resources Information Center

    Cole, Robert E.; Tachiki, Dennis S.

    1984-01-01

    The authors discuss the top three problems reported to hinder the spread of quality circles and evaluate selected solutions to them. The top problems include middle management resistance, lack of top management support, and employee resistance or apathy. Solutions discussed include social recognition and economic rewards. (CT)

  15. A Rare Cause of Cyanosis: Hepatopulmonary Syndrome Caused by Congenital Extrahepatic Portosystemic Shunt

    PubMed Central

    Ding, Xue-Yan; Chen, Feng; Zhao, Xian-Xian; Wu, Hong; Chen, Shao-Ping; Qin, Yong-Wen

    2011-01-01

    A 19-year-old male patient presented cyanosis and dyspnoea because of the presence of multiple pulmonary arteriovenous fistulas resulting in oxygen desaturation. The CTA revealed that intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. This is the first reported case of hepatopulmonary syndrome caused by congenital extrahepatic portosystemic shunt in which intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. PMID:22937464

  16. Renal Artery Stump to Inferior Vena Cava Fistula: Unusual Clinical Presentation and Transcatheter Embolization with the Amplatzer Vascular Plug

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taneja, Manish; Lath, Narayan, E-mail: lath_narayan@yahoo.com; Soo, Tan Bien

    Fistulous communication between the renal artery stump and inferior vena cava following nephrectomy is rare. We describe the case of a 52-year-old man with a fistula detected on investigation for hemolytic anemia in the postoperative period. The patient had had a nephrectomy performed 2 weeks prior to presentation for blunt abdominal trauma. The fistula was successfully occluded percutaneously using an Amplatzer vascular plug. The patient recovered completely and was discharged 2 weeks later.

  17. International Shock Congress (1st) and Annual Society Meeting (10th) Held in Montreal, Canada on 7-11 June 1987

    DTIC Science & Technology

    1987-10-01

    demonstrated that endotoxin shock is associated with a decrease in compliance of the superior and inferior vena cavae and probably £ Abstracts 17 central...site of a burn wound. METHODS: Anesthetized 350 gram male Long Evans rats were prepared by intrarenal inferior vena cava (IVC) ligation. The rats...elastase has been investigated in the superior vena caval and left atrium blood collected from 167 patients who underwent open heart surgery. The effect

  18. The Effects of Adaptation to a Low Carbohydrate/High Fat Diet and Pre-Exercise Feeding on Exercise Endurance, Metabolism, and Cardiovascular Dynamics in Swine

    DTIC Science & Technology

    1988-01-01

    were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV

  19. Blocking of the Hepatic Vein Outflow by Neointima Covering a Wallstent Across a Membranous Stenosis of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dutta, Usha; Garg, Pramod K.; Agarwal, Rajeev

    1999-11-15

    A 31-year-old man presented with idiopathic membranous obstruction of the suprahepatic inferior vena cava (IVC) and was treated by balloon dilation and placement of a Wallstent. The patient improved markedly. However, he developed obstruction of the hepatic vein outflow secondary to neointima formation over the stent that covered the hepatic vein ostia. The patient died of liver failure and septicemia. We believe that this is the first report of such a serious complication.

  20. Transjugular Intrahepatic Portosystemic Shunt Creation in Budd-Chiari Syndrome: Percutaneous Ultrasound-Guided Direct Simultaneous Puncture of the Portal Vein and Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali

    Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.

  1. Neonatal venous cerebral hemorrhage. Report of two cases.

    PubMed

    Misra, Sanjay N; Misra, Ashish K

    2003-10-15

    Intracranial pathological changes can occur as a result of impaired craniocervical venous return. Thrombosis of central venous access catheters was demonstrated in two neonates born at 38 and 27 weeks' gestation. Neither infant developed hemorrhage of prematurity as confirmed on cranial ultrasonography. Clinical evidence of vena cava thrombosis and associated spontaneous intraventricular hemorrhage developed on Day 24 and 36, respectively, and these findings were confirmed on imaging studies. In one infant the hemorrhage was accompanied by communicating hydrocephalus. The cause of the intracranial disease was attributable to the retrograde cerebral venous congestion. This, together with the primitive venous bed developing in the periventricular region, was associated with the spontaneous hemorrhage in the region of the foramen of Monro. To the authors' knowledge, this is the first report in the English-language literature of spontaneous neonatal intracerebral hemorrhage, due to thrombosis of the superior or inferior vena cava. The natural history of this condition is resolution without sequelae after appropriate therapeutic intervention for the vena cava thrombosis.

  2. Brown Alga Ecklonia cava polyphenol extract ameliorates hepatic lipogenesis, oxidative stress, and inflammation by activation of AMPK and SIRT1 in high-fat diet-induced obese mice.

    PubMed

    Eo, Hyeyoon; Jeon, You-jin; Lee, Myoungsook; Lim, Yunsook

    2015-01-14

    Obesity is considered to be a metaflammatory condition. Ecklonia cava, brown algae rich in polyphenols, has shown strong antioxidant activity in vitro. This study investigated the effect of E. cava polyphenol extract (ECPE) on the regulation of fat metabolism, inflammation, and the antioxidant defense system in high fat diet-induced obese mice. After obesity was induced by a high-fat diet (HFD), the mice were administered ECPE by gavage for 5 days/12 weeks. ECPE supplementation reduced body weight gain, adipose tissue mass, plasma lipid profiles, hepatic fat deposition, insulin resistance, and the plasma leptin/adiponectin ratio derived from HFD-induced obesity. Moreover, ECPE supplementation selectively ameliorated hepatic protein levels associated with lipogenesis, inflammation, and the antioxidant defense system as well as activation of AMPK and SIRT1. Collectively, ECPE supplement might have potential antiobesity effects via regulation of AMPK and SIRT1 in HFD-induced obesity.

  3. Automated implantable cardioverter defibrillator lead infection in a patient with previous superior vena cava thrombosis.

    PubMed

    Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave

    2015-11-04

    We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.

  4. Effect of post-filter anticoagulation on mortality in patients with cancer-associated pulmonary embolism.

    PubMed

    Kang, Jieun; Kim, Seon Ok; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung

    2018-05-17

    Malignancy is associated with an increased risk of venous thromboembolism. Inferior vena cava filters are a viable alternative when anticoagulation is infeasible because of the risk of bleeding. Although the current guidelines recommend that all patients with a vena cava filter be treated with anticoagulation treatment when the risk of bleeding is reduced, studies concerning the role of concomitant anticoagulation after vena cava filter insertion in high-risk patients are scarce. Since many cancer patients suffer from a high risk of hemorrhagic complications, we aimed to determine the effect of post-filter anticoagulation on mortality in patients with a malignant solid tumor. A retrospective cohort study of patients with pulmonary embolism was performed between January 2010 and May 2016. Patients with a solid tumor and vena cava filter inserted because of pulmonary embolism were included. Using Cox proportional hazards model, the prognostic effect of clinical variables was analyzed. A total of 180 patients were analyzed, with 143 patients receiving and 37 patients not receiving post-filter anticoagulation treatment. Mortality was not significantly different between the two groups. The presence of metastatic cancer and that of pancreatobiliary cancer were significant risk factors for mortality. However, post-filter anticoagulation did not show significant effect on mortality regardless of the stage of cancer. In patients with cancer-associated pulmonary embolism, the effect of post-filter anticoagulation on mortality may not be critical, especially in patients with a short life expectancy.

  5. Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Solar, Miroslav; Ceral, Jiri, E-mail: ceral.jiri@fnhk.c; Krajina, Antonin

    Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutivemore » patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.« less

  6. [Comparison of atrio-ventricular and total cavo-pulmonary connections versus atrio-pulmonary anastomosis for repair of tricuspid atresia in dogs].

    PubMed

    Yu, C; Liu, Y; Zhu, X; Li, Y; Li, Y

    2000-03-01

    To compare the hemodynamic effect and energy loss of atrio-ventricular and total cavo-pulmonary connections versus atrio-pulmonary anastomosis for modified Fontan in dogs. Fifteen adult mongrel dogs were divided into three groups. Group I underwent right atrium to right ventricle (using 50% and 25% right ventricular chamber, respectively) connection with the flap of valved homo-pulmonary artery (modified Bjoerk procedure). Group II underwent total cavo-pulmonary connection. Group III received atrio-pulmonary anastomosis. Right atrium pressure, pulmonary artery pressure, and cardiac output were measured by Swan-Ganz catheter. The volumes of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured by electromagnetic flowmeter. The flow-rate of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured echocardiographically. The fluid energy loss was calculated. The postoperative right atrium pressure in group I was lower than in group III (P < 0.05). The postoperative stroke index in group I and group II was higher than in group III (P < 0.01). The fluid energy loss was decreased when 50% or 25% right ventricle chamber was used (P < 0.01) and the fluid energy less in group II was less than in group III. Our experience suggested that atrio-ventricular connection and total cavo-pulmonary connection would be better than atrio-pulmonary anastomosis for modified Fontan repair of tricuspid valve atresia.

  7. SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitcham, T; Bouchard, R; Melancon, A

    Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic amore » human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.« less

  8. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass.

    PubMed

    Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-03-16

    A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.

  9. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass

    PubMed Central

    Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-01-01

    Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679

  10. Retrievable Inferior Vena Cava Filters for Venous Thromboembolism

    PubMed Central

    Win, Lei Lei

    2013-01-01

    Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292

  11. Catheter-Directed Thrombolysis of Inferior Vena Cava Thrombosis in a 13-Day-Old Neonate and Review of Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.

    Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.

  12. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  13. Needle versus Tube Thoracostomy in a Swine Model of Traumatic Tension Hemopneumothorax

    DTIC Science & Technology

    2009-03-01

    jugular vein, through the right atrium , and into the inferior vena cava . Serial digital C-arm chest x-rays allowed mea- surement of the shift from midline...wire in the inferior vena cava 1.34 cm to the right of the spinous processes. B: Insufflation resulted in a mediastinal shift of 2.15 cm to the left of...Received April 26, 2008, from the U.S. Army Institute of Surgical Re- search (JBH, JGM), Fort Sam Houston, Texas; the Naval Medical Cen- ter (STK), San Diego

  14. A Novel Technique for Inferior Vena Cava Filter Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn

    Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

  15. Total cavo-pulmonary connection without foreign material for asplenic heart associated with partial anomalous pulmonary venous connection.

    PubMed

    Agematsu, Kouta; Naito, Yuji; Aoki, Mitsuru; Fujiwara, Tadashi

    2008-04-01

    The presented case was a 3-year-old boy diagnosed with asplenia (SLL), double outlet right ventricle, pulmonary stenosis, atrioventricular septal defect, hypoplastic left ventricle and partial anomalous pulmonary venous connection to the superior vena cava. Partial anomalous pulmonary venous connection was repaired by translocation of pulmonary artery to avoid pulmonary venous obstruction when Glenn anastomosis was performed. Total cavo-pulmonary connection was established by re-routing the inferior vena cava to pulmonary artery using the atrial septal remnant and the left atrium free wall flap.

  16. [Structured quality report of urologic clinics according to section 137 SGB V. Useful information for the patient, marketing tool of the hospitals, leverage wielded by the health insurance companies, or junk data?].

    PubMed

    Volkmer, B; Petschl, S; Härtel, M; Bopp, G; Herkommer, K; Gschwend, J

    2006-04-01

    In 2005, German hospitals were legally obliged to publish a structured quality report on their data of 2004 including the top 10 diagnosis-related groups, top 10 diagnoses, and top 10 procedures for every specialty. The aim was to increase the transparency for patients, doctors, and health insurance companies. Comparing the quality reports of 248 departments of urology revealed very uniform distributions of diagnoses and diagnosis-related groups. There was a large variety of top 10 procedures, resulting from different interpretations of the coding system, leading to diminished accuracy. The quality reports provide coding specialists with important data, but for patients and nonspecialized doctors, this system is not helpful in improving transparency.

  17. Liver and Vena Cava En Bloc Resection for an Invasive Leiomyosarcoma Causing Budd-Chiari Syndrome, Under Veno-Venous Bypass and Liver Hypothermic Perfusion : Liver Hypothermic Perfusion and Veno-Venous Bypass for Inferior Vena Cava Leiomyosarcoma.

    PubMed

    Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele

    2017-02-01

    Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.

  18. Cold-Adapted Viral Attenuation (CAVA): Highly Temperature Sensitive Polioviruses as Novel Vaccine Strains for a Next Generation Inactivated Poliovirus Vaccine

    PubMed Central

    Sanders, Barbara P.; de los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G.; Song, Yutong; Cooper, Gillian; Crawt, Laura E.; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H. H. V.; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana

    2016-01-01

    The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4–9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV. PMID:27032093

  19. Mechanical support of total cavopulmonary connection with an axial flow pump.

    PubMed

    Riemer, R Kirk; Amir, Gabriel; Reichenbach, Steven H; Reinhartz, Olaf

    2005-08-01

    Even under optimal circumstances, total cavopulmonary connection is associated with a continuous late risk of death. Hemodynamics are distinctly abnormal, with increased systemic venous pressures and frequent low cardiac output. Our study uses a sheep model of total cavopulmonary connection to test the response to axial flow pump (Thoratec HeartMate II; Thoratec Corporation (Pleasanton, Calif)) support of total cavopulmonary connection, which might be suitable to treat patients with failing Fontan circulation. Eight sheep (42-48 kg) were studied. After pilot studies in 3 animals, 5 underwent both pump-supported and nonsupported total cavopulmonary connection in alternating sequence for up to 2 hours. This was achieved with a 12-mm polytetrafluoroethylene graft from the (distally ligated) superior vena cava to the main pulmonary artery and a cannula placed in the inferior vena cava with an attached 16-mm Dacron graft to the main pulmonary artery. Pressures (arterial, inferior vena cava, left atrium, and pulmonary artery) and flows (ascending aorta and inferior vena cava) were recorded over 1 hour both with unsupported total cavopulmonary connection and after placing an axial flow pump (Thoratec HeartMate II) between the inferior vena caval inflow cannula and the main pulmonary artery. Under nonsupported total cavopulmonary connection circulation, inferior vena caval and aortic blood flow decreased by nearly 50%. Inferior vena caval pressure nearly doubled, whereas arterial pressure decreased by one third. Pulmonary artery pressure became nonpulsatile; however, mean pulmonary artery pressure and left atrial pressure did not change significantly. With pump-supported Fontan circulation, cardiac output, inferior vena caval flow, and arterial pressure returned to baseline. Inferior vena caval pressure decreased to below baseline levels. Mean pulmonary artery pressure and left atrial pressure again remained unchanged. Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.

  20. Cold-Adapted Viral Attenuation (CAVA): Highly Temperature Sensitive Polioviruses as Novel Vaccine Strains for a Next Generation Inactivated Poliovirus Vaccine.

    PubMed

    Sanders, Barbara P; de Los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G; Song, Yutong; Cooper, Gillian; Crawt, Laura E; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H H V; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana

    2016-03-01

    The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4-9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV.

  1. Absence of inferior vena cava in 14-year old boy associated with deep venous thrombosis and positive Mycoplasma pneumoniae serum antibodies--a case report.

    PubMed

    Kalicki, Boleslaw; Sadecka, Monika; Wawrzyniak, Agata; Kozinski, Piotr; Dziekiewicz, Miroslaw; Jung, Anna

    2015-04-14

    Absence of the inferior vena cava is a rare vascular anomaly, which usually remains asymptomatic in childhood. It is recognized as the risk factor for deep venous thrombosis, since the collateral circulation does not provide adequate drainage of the lower limbs. Mycoplasma pneumoniae is a common cause of community-acquired pneumonia in school-aged children and adolescents. Mycoplasma pneumoniae infection might be associated with deep venous thrombosis but its pathophysiology remains unknown. According to previous reports, deep venous thrombosis due to Mycoplasma pneumoniae infection is associated with positive serum anticardiolipin antibodies. To our knowledge, we describe the first case of deep venous thrombosis associated with Mycoplasma pneumoniae serum antibodies indicating early stage of infection with negative anticardiolipin serum antibodies in adolescent with absence of inferior vena cava. 14-year old boy was admitted to the pediatric unit few days after the appendectomy complaining with pain of the left hip that caused him unable to walk. The pain was accompanied with subfebrile temperature. After clinical examination and additional tests, the boy was diagnosed with a deep venous thrombosis. Computed tomography revealed absence of the vena cava inferior distally to the hepatic veins and varices of the collateral circulation in the pelvis. Anticardiolipin IgM and IgG antibodies and antinuclear antibodies were not detected. Additionally, the Mycoplasma pneumoniae antibodies in classes IgM, IgA and IgG were detected in serum as another risk factor of thrombosis. After the initial treatment with low-molecular-weight heparin in combination with clarithromycin the clinical condition of the patient improved. The patient became a candidate for life-long anticoagulation therapy. In this case Mycoplasma pneumoniae antibodies were associated with deep venous thrombosis in child with congenital absence of inferior vena cava. Uncommonly for deep venous thrombosis due to Mycoplasma pneumoniae infection, anticardiolipin antibodies were not detected in serum. It is important to remember in clinical practice that Mycoplasma pneumoniae affects coagulability and may trigger thrombosis, especially in the presence of other risk factors. The pathophysiology of this process remains unknown.

  2. A prebiotic role of Ecklonia cava improves the mortality of Edwardsiella tarda-infected zebrafish models via regulating the growth of lactic acid bacteria and pathogen bacteria.

    PubMed

    Lee, WonWoo; Oh, Jae Young; Kim, Eun-A; Kang, Nalae; Kim, Kil-Nam; Ahn, Ginnae; Jeon, You-Jin

    2016-07-01

    In this study, the beneficial prebiotic roles of Ecklonia cava (E. cava, EC) were evaluated on the growth of lactic acid bacteria (LAB) and pathogen bacteria and the mortality of pathogen-bacteria infected zebrafish model. The result showed that the original E. cava (EC) led to the highest growth effects on three LABs (Lactobacillus brevis, L. brevis; Lactobacillus pentosus, L. pentosus; Lactobacillus plantarum; L. plantarum) and it was dose-dependent manners. Also, EC, its Celluclast enzymatic (ECC) and 100% ethanol extracts (ECE) showed the anti-bacterial activities on the fish pathogenic bacteria such as (Edwardsiella tarda; E. tarda, Streptococcus iniae; S. iniae, and Vibrio harveyi; V. harveyi). Interestingly, EC induced the higher production of the secondary metabolites from L. plantarum in MRS medium. The secondary metabolites produced by EC significantly inhibited the growth of pathogen bacteria. In further in vivo study, the co-treatment of EC and L. plantarum improved the growth and mortality of E. tarda-infected zebrafish as regulating the expression of inflammatory molecules such as iNOS and COX2. Taken together, our present study suggests that the EC plays an important role as a potential prebiotic and has a protective effect against the infection caused by E. tarda injection in zebrafish. Also, our conclusion from this evidence is that EC can be used and applied as a useful prebiotic. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Evaluating the effectiveness of implementing quality management practices in the medical industry.

    PubMed

    Yeh, T-M; Lai, H-P

    2015-01-01

    To discuss the effectiveness of 30 quality management practices (QMP) including Strategic Management, Balanced ScoreCard, Knowledge Management, and Total Quality Management in the medical industry. A V-shaped performance evaluation matrix is applied to identify the top ten practices that are important but not easy to use or implement. Quality Function Deployment (QFD) is then utilized to find key factors to improve the implementation of the top ten tools. The questionnaires were sent to the nursing staff and administrators in a hospital through e-mail and posts. A total of 250 copies were distributed and 217 copies were valid. The importance, easiness, and achievement (i.e., implementation level) of 30 quality management practices were used. Key factors for QMP implementation were sequenced in order of importance as top management involvement, inter-department communication and coordination, teamwork, hospital-wide participation, education and training, consultant professionalism, continuous internal auditing, computerized process, and incentive compensation. Top management can implement the V-shaped performance matrix to determine whether quality management practices need improvement and if so, utilize QFD to find the key factors for improvement.

  4. Analysis of classical guitars' vibrational behavior based on scanning laser vibrometer measurements

    NASA Astrophysics Data System (ADS)

    Czajkowska, Marzena

    2012-06-01

    One of the main goals in musical acoustics research is to link measurable, physical properties of a musical instrument with subjective assessments of its tone quality. The aim of the research discussed in this paper was to observe the structural vibrations of different class classical guitars in relation to their quality. This work focuses on mid-low-and low-class classical (nylon-stringed) guitars. The main source of guitar body vibrations come from top and back plate vibrations therefore these were the objects of structural mode measurements and analysis. Sixteen classical guitars have been investigated, nine with cedar and seven with spruce top plate. Structural modes of top and back plates have been measured with the aid of a scanning laser vibrometer and the instruments were excited with a chirp signal transferred by bone vibrator. The issues related to excitor selection have been discussed. Correlation and descriptive statistics of top and back plates measurement results have been investigated in relation to guitar quality. The frequency range of 300 Hz to 5 kHz as well as selected narrowed frequency bands have been analyzed for cedar and spruce guitars. Furthermore, the influence of top plate wood type on vibration characteristics have been observed on three pairs of guitars. The instruments were of the same model but different top plate material. Determination and visualization of both guitar plates' modal patterns in relation to frequency are a significant attainment of the research. Scanning laser vibrometer measurements allow particular mode observation and therefore mode identification, as opposed to sound pressure response measurements. When correlating vibration characteristics of top and back plates it appears that Pearson productmoment correlation coefficient is not a parameter that associates with guitar quality. However, for best instruments with cedar top, top-back correlation coefficient has relatively greater value in 1-2 kHz band and lower in the range of 2,5-5 kHz in comparison with low-class instruments. The study showed that variance, which is a measure of statistical dispersion, is a relevant parameter. The better the quality of the guitar the greater the variance value in 1-2 kHz band. It was observed that higher-quality instruments are characterized by stronger structural resonances of top plate in the range of 4-5 kHz, which means that luthiers should pay special attention to top plate vibrational behaviour in this particular frequency band. Additionally, the result analysis show that best spruce guitars are distinguished by greater top plate vibrations in the range of 2-3 kHz in opposite to best cedar instruments. It can be assumed that top plate vibrations in this particular frequency band may be associated with subjective impression of tone brightness, as commonly known opinion indicates that guitars with spruce tops sound relatively "brighter" in comparison to cedar-top instruments.

  5. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  6. Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com

    Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less

  7. Strategies for the Management of SVC Stent Migration into the Right Atrium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, J. D., E-mail: drjeremytaylor@yahoo.co.uk; Lehmann, E. D.; Belli, A.-M.

    Purpose. Stent migration into the right atrium is a potentially fatal complication of stenting in the venous system and is most likely to occur during the treatment of superior vena cava obstruction. Endovascular approaches that can salvage this hazardous situation are described and the keys to successful treatment are highlighted. Materials and Methods. Four different strategies are reviewed: (1) snaring the stent directly, (2) angioplasty balloon-assisted snaring of the stent, (3) guide wire-assisted snaring of the stent, and (4) superior vena cava-to-inferior vena cava bridging stent. Results. These techniques have been employed in the successful management of four cases. Nomore » short- or long-term complications as a result of these maneuvers have been identified. Additional treatment of the underlying disease was possible at the same time in each case. Conclusion. We conclude that prompt management of right atrial stent migration is essential and can be successfully achieved by a variety of 'bale-out' techniques which are within the technical range of most interventional radiologists.« less

  8. Calcified inferior vena cava and right atrial myxoma in an 18-month-old male: A case report.

    PubMed

    Chen, Renwei; Deng, Xicheng; Luo, Jinwen; Huang, Peng

    2018-06-01

    Cardiac myxomas are the most frequent primary cardiac tumor in adults. The incidence in pediatric patients is extremely low. Heavy calcification of an atrial myxoma is uncommon in children. An 18-month-old boy was admitted for a significant precordial systolic murmur. Transthoracic echocardiography revealed a cardiac mass extending from the inferior vena cava across the right atrium and tricuspid valve into the right ventricle with severe tricuspid regurgitation. According to the echocardiography result, the patient was diagnosed with an inferior vena cava and right atrial tumor with tricuspid regurgitation. After the diagnosis, the patient underwent removal of the tumor via median sternotomy. The mass was removed under cardiopulmonary bypass with deep hypothermia circulatory arrest. The tricuspid valve was repaired by valvuloplasty and annuloplasty. The postoperative recovery was unremarkable. Follow-up echocardiogram at 1 month revealed moderate tricuspid regurgitation without myxoma recurrence. Heavy calcification of an atrial myxoma is uncommon especially in children. Definitive therapy for myxomas requires prompt surgical excision and long-term follow-up is recommended in children although recurrence after excision is rare.

  9. Liver hanging maneuver for right hemiliver in situ donation--anatomical considerations.

    PubMed

    Trotovsek, B; Gadzijev, E M; Ravnik, D; Hribernik, M

    2006-01-01

    An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4-6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7+/-3.4 mm and to the entrance of segment 9 veins was 5.0+/-0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7+/-2.3 mm (range 2-15 mm). The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%).

  10. Intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage in heterotaxy syndrome.

    PubMed

    Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz

    2010-08-01

    A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.

  11. Superior Vena Cava Stent Migration into the Pulmonary Artery Causing Fatal Pulmonary Infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anand, Girija, E-mail: gijanandm@hotmail.com; Lewanski, Conrad R.; Cowman, Steven A.

    2011-02-15

    Migration of superior vena cava (SVC) stents is a well-recognised complication of their deployment, and numerous strategies exist for their retrieval. To our knowledge, only three cases of migration of an SVC stent to the pulmonary vasculature have previously been reported. None of these patients developed complications that resulted in death. We report a case of SVC stent migration to the pulmonary vasculature with delayed pulmonary artery thrombosis and death from pulmonary infarction. We conclude that early retrieval of migrated stents should be performed to decrease the risk of serious complications.

  12. Extreme premature with persistent left superior vena cava.

    PubMed

    Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin

    2017-10-01

    Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.

  13. Inferior Vena Cava Filters to Prevent Pulmonary Embolism: Systematic Review and Meta-Analysis.

    PubMed

    Bikdeli, Behnood; Chatterjee, Saurav; Desai, Nihar R; Kirtane, Ajay J; Desai, Mayur M; Bracken, Michael B; Spencer, Frederick A; Monreal, Manuel; Goldhaber, Samuel Z; Krumholz, Harlan M

    2017-09-26

    Inferior vena cava (IVC) filters are widely used for prevention of pulmonary embolism (PE). However, uncertainty persists about their efficacy and safety. The authors conducted a systematic review and meta-analysis of the published reports on the efficacy and safety of IVC filters. The authors searched PubMed, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov through October 3, 2016, for randomized controlled trials (RCTs) or prospective controlled observational studies of IVC filters versus none in patients at risk of PE. Inverse variance fixed-effects models with odds ratio (OR) as the effect measure were used for primary analyses. Main outcomes included subsequent PE, PE-related mortality, all-cause mortality, and subsequent deep vein thrombosis (DVT). The authors' search retrieved 1,986 studies, of which 11 met criteria for inclusion (6 RCTs and 5 prospective observational studies). Quality of evidence for RCTs was low to moderate. Overall, patients receiving IVC filters had lower risk for subsequent PE (OR: 0.50; 95% confidence interval [CI]: 0.33 to 0.75); increased risk for DVT (OR: 1.70; 95% CI: 1.17 to 2.48); nonsignificantly lower PE-related mortality (OR: 0.51; 95% CI: 0.25 to 1.05); and no change in all-cause mortality (OR: 0.91; 95% CI: 0.70 to 1.19). Limiting the results to RCTs showed similar results. Findings were substantively similar across a wide range of sensitivity analyses. Very few prospective controlled studies, with limited quality of evidence, exist regarding the efficacy and safety of IVC filters. Overall, filters appear to reduce the risk of subsequent PE, increase the risk for DVT, and have no significant effect on overall mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  14. Highlights of Total Quality Management in the Department of Defense: Lessons Learned, Quality Measurements and Innovative Practices

    DTIC Science & Technology

    1991-09-26

    Quality Management (TQM) through both quantitative and qualitative analyses. Interviews were conducted with top executives from ten exemplar organizations within the Department of Defense (DOD). Survey questionnaires on perceptions of quality practices were administered to a sample of 102 representing members of the executive steering committees at the same organizations. Research identifies lessons learned by top executives during TQM implementation, discusses measures of organization-wide quality management , specifies evaluation mechanisms to

  15. Cardiopulmonary changes during laparoscopy and vessel injury: comparison of CO2 and helium in an animal model.

    PubMed

    Jacobi, C A; Junghans, T; Peter, F; Naundorf, D; Ordemann, J; Müller, J M

    2000-11-01

    Injury of venous vessels during elevated intraperitoneal pressure is thought to cause possible fatal gas embolism, and helium may be dangerous because of its low solubility. Twenty pigs underwent laparoscopy with either CO2 (n=10) or helium (n=10) with a pressure of 15 mm Hg and standardized laceration (1 cm) of the vena cava inferior. After 30 s, the vena cava was clamped, closed endoscopically by a running suture and unclamped again. During the procedure changes of cardiac output (CO), heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), pulmonary artery pressure (PAP), pulmonary artery wedge pressure (PAWP), end tidal CO2 pressure (PETCO2), and arterial blood gas analyses (pH, pO2 and pCO2) were investigated. No animal died during the experimental course (mean blood loss during laceration: CO2, 157+/-50 ml; helium, 173+/-83 ml). MAP and CO values showed a decrease after laceration of the vena cava in both groups that had already been completely compensated for before suturing. PETCO2 increased significantly after CO2 insufflation (P<0.01), while helium showed no effect. Laceration of the vena cava caused no significant changes in PETCO2 values in either group. Significant acidosis and an increase of pCO2 were only found in the CO2 group. The incidence of gas embolism during laparoscopy and accidental vessel injury seems to be very low. With the exception of acidosis and an increase of PETCO2 in the CO2 group, there were no differences in cardiopulmonary function between insufflation of CO2 and helium.

  16. Inferior Vena Cava Oxygen Saturation during the First Three Postnatal Days in Preterm Newborns with and without Patent Ductus Arteriosus

    PubMed Central

    Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin

    2014-01-01

    Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418

  17. From transpressional to transtensional tectonics in Northern Central America controlled by Cocos - Caribbean subduction coupling change

    NASA Astrophysics Data System (ADS)

    Alonso-Henar, Jorge; Alvarez-Gomez, José Antonio; Jesús Martinez-Diaz, José

    2017-04-01

    The Central American Volcanic Arc (CAVA) is located at the western margin of the Caribbean plate, over the Chortís Block, spanning from Guatemala to Costa Rica. The CAVA is associated to the subduction of the Cocos plate under the Caribbean plate at the Middle America Trench. Our study is focused in the Salvadorian CAVA segment, which is tectonically characterized by the presence of the El Salvador Fault Zone (ESFZ), part of the western boundary of a major block forming the Caribbean plate (the Chortis Block). The structural evolution of the western boundary of the Chortis Block, particularly in the CAVA crossing El Salvador remains unknown. We have done a kinematic analysis from seismic and fault slip data and combined our results with a review of regional previous studies. This approach allowed us to constrain the tectonic evolution and the forces that control the deformation in northern Central America. Along the active volcanic arc we identified active transtensional deformation. On the other hand, we have identified two deformation phases in the back arc region: A first one of transpressional wrenching close to simple shearing (Miocene); and a second one characterized by almost E-W extension. Our results reveal a change from transpressional to transtensional shearing coeval with a migration of the volcanism towards the trench in Late Miocene times. This strain change could be related with a coupled to decoupled transition on the Cocos - Caribbean subduction interface, which could be related to a slab roll-back of the Cocos Plate beneath the Chortis Block. The combination of different degrees of coupling on the subduction interface, together with a constant relative eastward drift of the Caribbean Plate, control the deformation style along the western boundary of the Chortis Block.

  18. Percutaneous Transluminal Angioplasty for Complete Membranous Obstruction of Suprahepatic Inferior Vena Cava: Long-Term Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com; Akdogan, Meral, E-mail: akdmeral@yahoo.com; Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com

    PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture andmore » traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.« less

  19. Correlation Between Quality of Evidence and Number of Citations in Top 50 Cited Articles on Elbow Medial Ulnar Collateral Ligament Surgery.

    PubMed

    Jack, Robert A; Sochacki, Kyle R; Morehouse, Hannah A; McCulloch, Patrick C; Lintner, David M; Harris, Joshua D

    2018-04-01

    Several studies have analyzed the most cited articles in shoulder, elbow, pediatrics, and foot and ankle surgery. However, no study has analyzed the quality of the most cited articles in elbow medial ulnar collateral ligament (UCL) surgery. To (1) identify the top 50 most cited articles related to UCL surgery, (2) determine whether there was a correlation between the top cited articles and level of evidence, and (3) determine whether there was a correlation between study methodological quality and the top cited articles. Systematic review. Web of Science and Scopus online databases were searched to identify the top 50 cited articles in UCL surgery. Level of evidence, number of times cited, year of publication, name of journal, country of origin, and study type were recorded for each study. Study methodological quality was analyzed for each article with the Modified Coleman Methodology Score (MCMS) and the Methodological Index for Non-randomized Studies (MINORS). Correlation coefficients were calculated. The 50 most cited articles were published between 1981 and 2015. The number of citations per article ranged from 20 to 301 (mean ± SD, 71 ± 62 citations). Most articles (92%) were from the United States and were level 3 (16%), level 4 (58%), or unclassified (16%) evidence. There were no articles of level 1 evidence quality. The mean MCMS and MINORS scores were 28.1 ± 13.4 (range, 3-52) and 9.2 ± 3.6 (range, 2-19), respectively. There was no significant correlation between the mean number of citations and level of evidence or quality ( r s = -0.01, P = .917), MCMS ( r s = 0.09, P = .571), or MINORS ( r s = -0.26, P = .089). The top 50 cited articles in UCL surgery constitute a low level of evidence and low methodological quality, including no level 1 articles. There was no significant correlation between the mean number of citations and level of evidence or study methodological quality. However, weak correlations were observed for later publication date and improved level of evidence and methodological quality.

  20. Correlation Between Quality of Evidence and Number of Citations in Top 50 Cited Articles on Elbow Medial Ulnar Collateral Ligament Surgery

    PubMed Central

    Jack, Robert A.; Sochacki, Kyle R.; Morehouse, Hannah A.; McCulloch, Patrick C.; Lintner, David M.; Harris, Joshua D.

    2018-01-01

    Background: Several studies have analyzed the most cited articles in shoulder, elbow, pediatrics, and foot and ankle surgery. However, no study has analyzed the quality of the most cited articles in elbow medial ulnar collateral ligament (UCL) surgery. Purpose: To (1) identify the top 50 most cited articles related to UCL surgery, (2) determine whether there was a correlation between the top cited articles and level of evidence, and (3) determine whether there was a correlation between study methodological quality and the top cited articles. Study Design: Systematic review. Methods: Web of Science and Scopus online databases were searched to identify the top 50 cited articles in UCL surgery. Level of evidence, number of times cited, year of publication, name of journal, country of origin, and study type were recorded for each study. Study methodological quality was analyzed for each article with the Modified Coleman Methodology Score (MCMS) and the Methodological Index for Non-randomized Studies (MINORS). Correlation coefficients were calculated. Results: The 50 most cited articles were published between 1981 and 2015. The number of citations per article ranged from 20 to 301 (mean ± SD, 71 ± 62 citations). Most articles (92%) were from the United States and were level 3 (16%), level 4 (58%), or unclassified (16%) evidence. There were no articles of level 1 evidence quality. The mean MCMS and MINORS scores were 28.1 ± 13.4 (range, 3-52) and 9.2 ± 3.6 (range, 2-19), respectively. There was no significant correlation between the mean number of citations and level of evidence or quality (rs = –0.01, P = .917), MCMS (rs = 0.09, P = .571), or MINORS (rs = –0.26, P = .089). Conclusion: The top 50 cited articles in UCL surgery constitute a low level of evidence and low methodological quality, including no level 1 articles. There was no significant correlation between the mean number of citations and level of evidence or study methodological quality. However, weak correlations were observed for later publication date and improved level of evidence and methodological quality. PMID:29780841

  1. Vertebral Uptake of Tc-99m Macroaggregated Albumin (MAA) with SPECT/CT Occurring in Superior Vena Cava Obstruction.

    PubMed

    Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma

    2016-09-01

    A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.

  2. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  3. Surgical repair of an unusual type of supra-cardiac total anomalous pulmonary venous connection to the superior vena cava.

    PubMed

    Perri, Gianluigi; Filippelli, Sergio; Kirk, Richard; Hasan, Asif; Griselli, Massimo

    2012-05-01

    Anomalies of the pulmonary venous drainage vary widely in their anatomic spectrum and clinical presentation. We describe an unusual case of supra-cardiac total anomalous pulmonary venous connection (TAPVC), where the pulmonary veins drained directly in the posterior aspect of proximal right superior vena cava (SVC) through separate ostia. The veins were re-routed with a patch to the left atrium via the secundum atrial septal defect (ASD). The continuity between distal SVC and right atrium was re-established by re-implanting the SVC to the right atrial appendage (Warden Procedure). © 2012 Wiley Periodicals, Inc.

  4. Focal Atrial Tachycardia Arising from the Inferior Vena Cava

    PubMed Central

    Lim, Yeong-Min; Uhm, Jae-Sun

    2017-01-01

    The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006

  5. Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM

    PubMed Central

    Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi

    2017-01-01

    Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027

  6. Role of bilateral inferior petrosal sinus sampling (BIPSS) in the diagnosis of Cushing’s disease in a patient with double superior vena cava

    PubMed Central

    Tashi, Sonam; Ng, Keng Sin

    2015-01-01

    Cushing’s syndrome is known to have a wide spectrum of clinical presentation with debilitating consequences and morbidity if not diagnosed and treated in time. Sometimes the diagnosis of Cushing’s syndrome can be challenging to the endocrinologist, especially when the usual battery of biochemical tests and advanced cross-sectional imaging is negative or inconclusive. We described a case in which the use of bilateral inferior petrosal sinus sampling (BIPSS) was conclusive albeit being technically challenging (due to a rare incidental finding of double superior vena cava) and invasive in nature. PMID:26629301

  7. Rapid guiding catheter swapping for management of rupture during percutaneous venoplasty for idiopathic occlusion of superior vena cava.

    PubMed

    Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay

    2015-04-01

    Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.

  8. Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications

    PubMed Central

    DeYoung, Elliot; Minocha, Jeet

    2016-01-01

    Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472

  9. Dieckol, a phlorotannin isolated from a brown seaweed, Ecklonia cava, inhibits adipogenesis through AMP-activated protein kinase (AMPK) activation in 3T3-L1 preadipocytes.

    PubMed

    Ko, Seok-Chun; Lee, Myoungsook; Lee, Ji-Hyeok; Lee, Seung-Hong; Lim, Yunsook; Jeon, You-Jin

    2013-11-01

    In this study, we assessed the potential inhibitory effect of 5 species of brown seaweeds on adipogenesis the differentiation of 3T3-L1 preadipocytes into mature adipocytes by measuring Oil-Red O staining. The Ecklonia cava extract tested herein evidenced profound adipogenesis inhibitory effect, compared to that exhibited by the other four brown seaweed extracts. Thus, E. cava was selected for isolation of active compounds and finally the three polyphenol compounds of phlorotannins were obtained and their inhibitory effect on adipogenesis was observed. Among the phlorotannins, dieckol exhibited greatest potential adipogenesis inhibition and down-regulated the expression of peroxisome proliferator-activated receptor-γ (PPARγ), CCAAT/enhancer-binding proteins (C/EBPα), sterol regulatory element-binding protein 1 (SREBP1) and fatty acid binding protein 4 (FABP4) in a dose-dependent manner. The specific mechanism mediating the effects of dieckol was confirmed by AMP-activated protein kinase (AMPK) activation. These results demonstrate inhibitory effect of dieckol compound on adipogenesis through the activation of the AMPK signal pathway. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Should We Remove the Retrievable Cook Celect Inferior Vena Cava Filter? Eight Years of Experience at a Single Center.

    PubMed

    Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan

    2017-12-01

    The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.

  11. Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2016-05-01

    To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.

  12. Cardiopulmonary bypass-assisted surgery for the treatment of Xp11.2 translocation/TFE3 gene fusion renal cell carcinoma with a tumor thrombus within the inferior vena cava: A case report.

    PubMed

    Zhu, Guanchen; Qiu, Xuefeng; Chen, Xianchen; Liu, Guangxiang; Zhang, Gutian; Gan, Weidong; Guo, Hongqian

    2015-12-01

    Renal cell carcinoma (RCC) accounts for 85-90% of kidney cancers, which in turn account for 2-3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7-10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC.

  13. Cardiopulmonary bypass-assisted surgery for the treatment of Xp11.2 translocation/TFE3 gene fusion renal cell carcinoma with a tumor thrombus within the inferior vena cava: A case report

    PubMed Central

    ZHU, GUANCHEN; QIU, XUEFENG; CHEN, XIANCHEN; LIU, GUANGXIANG; ZHANG, GUTIAN; GAN, WEIDONG; GUO, HONGQIAN

    2015-01-01

    Renal cell carcinoma (RCC) accounts for 85–90% of kidney cancers, which in turn account for 2–3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7–10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC. PMID:26788164

  14. Inferior vena cava tumor thrombus after partial nephrectomy for renal cell carcinoma.

    PubMed

    Akatsuka, Jun; Suzuki, Yasutomo; Hamasaki, Tsutomu; Shindo, Takao; Yanagi, Masato; Kimura, Go; Yamamoto, Yoichiro; Kondo, Yukihiro

    2014-03-29

    Partial nephrectomy is now the gold standard treatment for small renal tumors. Local recurrence is a major problem after partial nephrectomy, and local recurrence in the remnant kidney after partial nephrectomy is common. A 77-year-old man underwent right partial nephrectomy for a T1 right renal cell carcinoma. Microscopic examination revealed a clear cell renal carcinoma, grade 2, stage pT3a. Although the surgical margin was negative, the carcinoma invaded the perirenal fat, and vascular involvement was strongly positive. Thirty months after partial nephrectomy, an enhanced computed tomographic scan showed local recurrence of the renal cell carcinoma extending into the inferior vena cava without renal mass. Hence, we performed right radical nephrectomy and intracaval thrombectomy. Microscopic examination revealed a clear cell carcinoma grade 2, stage pT3a + b. The patient is still alive with no evidence of recurrence 10 months post-procedure. To our knowledge, local recurrence of renal cell carcinoma extending into the inferior vena cava after partial nephrectomy has not been reported in the literature. Our case report emphasizes the importance of strict surveillance of patients after partial nephrectomy, especially for those with renal cell carcinoma positive for microvessel involvement.

  15. A case of huge colon carcinoma and right renal angiomyolipoma accompanied by proximal deep venous thrombosis, pulmonary embolism and tumor thrombus in the renal vein.

    PubMed

    Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro

    2008-10-01

    A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.

  16. Liver hanging maneuver for right hemiliver in situ donation – anatomical considerations

    PubMed Central

    Gadžijev, E.M.; Ravnik, D.; Hribernik, M.

    2006-01-01

    Background. An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4–6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. Materials and methods. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. Results. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7±3.4 mm and to the entrance of segment 9 veins was 5.0±0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7±2.3 mm (range 2–15 mm). Discussion. The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%). PMID:18333236

  17. Interventional Treatment of Severe Tricuspid Regurgitation: Early Clinical Experience in a Multicenter, Observational, First-in-Man Study.

    PubMed

    Lauten, Alexander; Figulla, Hans R; Unbehaun, Axel; Fam, Neil; Schofer, Joachim; Doenst, Torsten; Hausleiter, Joerg; Franz, Marcus; Jung, Christian; Dreger, Henryk; Leistner, David; Alushi, Brunilda; Stundl, Anja; Landmesser, Ulf; Falk, Volkmar; Stangl, Karl; Laule, Michael

    2018-02-01

    Transcatheter caval valve implantation is under evaluation as a treatment option for inoperable patients with severe tricuspid regurgitation (TR). The procedure involves the catheter-based implantation of bioprosthetic valves in the inferior vena cava and superior vena cava to treat symptoms associated with TR. This study is the first to evaluate the feasibility, safety, and efficacy of this interventional concept. Twenty-five patients (mean age, 73.9±7.6 years; women, 52.0%) with severe symptomatic TR despite optimal medical treatment deemed unsuitable for surgery were treated with caval valve implantation under a compassionate clinical use program. Technical feasibility defined as procedural success, hemodynamic effect defined as venous pressure reduction, and safety defined as periprocedural adverse events were evaluated, with clinical follow-up at discharge and up to 12 months. The functional impact was evaluated by assessment of New York Heart Association class at the time of hospital discharge. The total number of valves implanted in the caval position was 31. Patients were treated with single (inferior vena cava-only; n=19; 76.0%) or bicaval valve implantation (inferior vena cava+superior vena cava; n=6; 24.0%). Either balloon-expandable valves (Sapien XT/3: n=18; 72.0%) or self-expandable valves (TricValve: n=6; 24.0%; Directflow: n=1; 4.0%) were used. Procedural success was achieved in 96% (n=24). Early and late valve migration requiring surgical intervention occurred in 1 patient each. Thirty-day and in-hospital mortality were 8% (2 of 25) and 16% (4 of 25). Causes of in-hospital mortality included respiratory (n=1) or multiple organ failure (n=3) and were not linked to the procedure. Mean overall survival in the study cohort was 316±453 days (14-1540 days). Caval valve implantation for the treatment of severe TR and advanced right ventricular failure is associated with a high procedural success rate and seems safe and feasible in an excessive-risk cohort. The study demonstrates hemodynamic efficacy with consistent elimination of TR-associated venous backflow and initial clinical improvement. These results encourage further trials to determine which patients benefit most from this interventional approach. © 2018 American Heart Association, Inc.

  18. Large thoracic tumor without superior vena cava syndrome.

    PubMed

    Garmpis, Nikolaos; Damaskos, Christos; Patelis, Nikolaos; Dimitroulis, Dimitrios; Spartalis, Eleftherios; Tomos, Ioannis; Garmpi, Anna; Spartalis, Michael; Antoniou, Efstathios A; Kontzoglou, Konstantinos; Tomos, Periklis

    2017-04-10

    A 62 year-old male with long-standing smoking history presented with hemoptysis. Plain chest x-ray showed abnormal findings proximate to the right pulmonary hilum. Bronchoscopy revealed a fragile exophytic tumor of the right wall of the lower third of the trachea, infiltrating the right main bronchus (75% stenosis) and the right upper lobar bronchus (near total occlusion). Contrast-enhanced chest CT demonstrated a 7.2x4.9 cm tumor contiguous to the above-mentioned structures, mediastinal lymph node pathology, and a vessel coursing inferiorly to the left of the aortic arch and anterior to the left hilum. Despite the tumor constricting the right superior vena cava, no signs of superior vena cava syndrome were present. In this case, the patient does not present with Superior Vena Cava (SVC) syndrome, as expected due to the constriction of the (right) SVC caused by the tumor, since head and neck veins drain through the Persistent Left Superior Vena Cava (PLSVC). PLSVC is the most common thoracic venous anomaly with an incidence of 0.3% to 0.5% of the general population and it is a congenital anomaly caused by the failure of the left anterior cardinal vein to regress and to consequently form the ligament of Marshall during fetal development. It is associated with absence of the left brachiocephalic vein and in 10 to 20% of cases the right SVC is absent. Two potential draining points of the PLSVC have been previously reported. In the majority of cases PLSVC drains directly into the coronary sinus, but less frequently it drains into the left atrium or the left superior pulmonary vein. In cases where the PLSVC drains into the coronary sinus, congenital heart defects are rare. The patient usually remains asymptomatic and PLSVC is an incidental finding during radiographic imaging or medical procedures. When the PLSVC drains into the left atrium or the left superior pulmonary vein, a right-to-left shunt is formed; a condition usually asymptomatic. In some reported cases this PLSVC variant presents with persistent, unexplained hypoxia or cyanosis and embolisation causing recurrent transient ischemic attacks and/or cerebral abscesses. This PLSVC variant is more often associated with absence of the right SVC and congenital heart abnormalities.

  19. Behind the Scenes

    ERIC Educational Resources Information Center

    Dahnert, Roger; Pack, Andrew

    2007-01-01

    High-quality sports facilities are an essential tool in recruiting top collegiate athletes and coaches. They enhance the school's competitiveness and enable expansion of the school's sports programs. In choosing schools, top athletes and coaches assess the quality of the stadium, playing fields, track and courts. But they also will be looking at…

  20. Outcome of Resection and Chemotherapy versus Chemotherapy Alone for Retroperitoneal Recurrence of Testicular Cancer Involving the Inferior Vena Cava: A Retrospective Cohort Study of 22 Consecutive Patients.

    PubMed

    Illuminati, Giulio; Calio, Francesco G; Angelici, Alberto M; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2016-07-01

    Optimal treatment strategy for retroperitoneal recurrence of testicular cancer involving the inferior vena cava (IVC) is uncertain. The purpose of this study was to validate the hypothesis that surgical resection, en-bloc with the involved segment of IVC and its subsequent reconstruction followed by chemotherapy, would yield better oncologic results than chemotherapy alone. Two consecutive series of patients with retroperitoneal recurrence of testicular cancer involving the IVC, treated with surgical resection plus chemotherapy (group A, n=14) or chemotherapy alone (group B, n=8) were retrospectively reviewed. The mean duration of follow-up was was 65 months (range=8-184). Operative mortality and morbidity in group A, response to chemotherapy in group B, disease-specific survival and quality adjusted life-years (QALY) for both groups, were primary end-points of the study. Postoperative mortality and morbidity (group A) were, respectively, nil and 14%. In group B, two patients (25%) fully responded to chemotherapy and remained free from disease progression. Disease-specific survival at 3 and 5 years was 81% and 54% in group A and 36% in group B both at 3 and 5 years, respectively (p=0.02). QALY was 3.92 in group A and 0.77 for both 3 and 5 years in group B, respectively, (p=0.031). En bloc resection of retroperitoneal recurrence of testicular tumors invading the IVC, followed by chemotherapy, allows a better survival rate compared to chemotherapy alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  1. Psoas abscess secondary to retroperitoneal distant metastases from squamous cell carcinoma of the cervix with thrombosis of the inferior vena cava and duodenal infiltration treated by Whipple procedure: A case report and review of the literature.

    PubMed

    Mehdorn, Matthias; Petersen, Tim-Ole; Bartels, Michael; Jansen-Winkeln, Boris; Kassahun, Woubet Tefera

    2016-08-11

    Psoas abscess is a rare clinical disease of various origins. Most common causes include hematogenous spread of bacteria from a different primary source, spondylodiscitis or perforated intestinal organs. But rarely some abscesses are related to malignant metastatic disease. In this case report we present the case of a patient with known squamous cell carcinoma of the cervix treated with radio-chemotherapy three years prior. She now presented with a psoas abscess and subsequent complete inferior vena cava thrombosis, as well as duodenal and vertebral infiltration. The abscess was drained over a prolonged period of time and later was found to be a complication caused by metastases of the cervical carcinoma. Due to the massive extent of the metastases a Whipple procedure was performed to successfully control the local progress of the metastasis. As psoas abscess is an unspecific disease which presents with non-specific symptoms adequate therapy may be delayed due to lack of early diagnostic results. This case report highlights the difficulties of managing a malignant abscess and demonstrates some diagnostic pitfalls that might be encountered. It stresses the necessity of adequate diagnostics to initiate successful therapy. Reports on psoas abscesses that are related to cervix carcinoma are scarce, probably due to the rarity of this event, and are limited to very few case reports. We are the first to report a case in which an extensive and complex abdominal procedure was needed for local control to improve quality of life.

  2. A top-down approach to fabrication of high quality vertical heterostructure nanowire arrays.

    PubMed

    Wang, Hua; Sun, Minghua; Ding, Kang; Hill, Martin T; Ning, Cun-Zheng

    2011-04-13

    We demonstrate a novel top-down approach for fabricating nanowires with unprecedented complexity and optical quality by taking advantage of a nanoscale self-masking effect. We realized vertical arrays of nanowires of 20-40 nm in diameter with 16 segments of complex longitudinal InGaAsP/InP structures. The unprecedented high quality of etched wires is evidenced by the narrowest photoluminescence linewidth ever produced in similar wavelengths, indistinguishable from that of the corresponding wafer. This top-down, mask-free, large scale approach is compatible with the established device fabrication processes and could serve as an important alternative to the bottom-up approach, significantly expanding ranges and varieties of applications of nanowire technology.

  3. Lexical Expertise and Reading Skill: Bottom-Up and Top-Down Processing of Lexical Ambiguity

    ERIC Educational Resources Information Center

    Andrews, Sally; Bond, Rachel

    2009-01-01

    The lexical quality hypothesis assumes that skilled readers rely on high quality lexical representations that afford autonomous lexical retrieval and reduce the need to rely on top-down context. This experiment investigated this hypothesis by comparing the performance of adults classified on reading comprehension and spelling performance. "Lexical…

  4. Primary Pulmonary Ewing's Sarcoma: Rare Cause of Superior Vena Cava Syndrome in Children.

    PubMed

    Mehra, Shibani; Atwal, Swapndeep Singh; Garga, Umesh Chandra

    2014-08-01

    Ewing's sarcoma is a common malignant bone tumour presenting in children and young adults. Rarely extra- skeletal soft tissues and visceral organs can also be the site of origin of Ewing's sarcoma. Primary pulmonary Ewing's sarcoma is an extremely rare malignancy which occurs in the paediatric population. We report an unusual case of primary pulmonary Ewing's sarcoma in a nine year old girl who presented with features of superior vena cava syndrome in the emergency department. The diagnosis was confirmed pathologically both by light microscopy and immunohistochemistry. The patient was put on chemotherapy and surgery was planned but the patient expired within three days of starting chemotherapy.

  5. Renal Sinus Fat Invasion and Tumoral Thrombosis of the Inferior Vena Cava-Renal Vein: Only Confined to Renal Cell Carcinoma

    PubMed Central

    Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra

    2014-01-01

    Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC. PMID:25506021

  6. Renal sinus fat invasion and tumoral thrombosis of the inferior vena cava-renal vein: only confined to renal cell carcinoma.

    PubMed

    Acar, Turker; Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra

    2014-01-01

    Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC.

  7. Brain Abscess Associated with Isolated Left Superior Vena Cava Draining into the Left Atrium in the Absence of Coronary Sinus and Atrial Septal Defect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erol, Ilknur; Cetin, I. Ilker; Alehan, Fuesun

    A previously healthy 12-year-old girl presented with severe headache for 2 weeks. On physical examination, there was finger clubbing without apparent cyanosis. Neurological examination revealed only papiledema without focal neurologic signs. Cerebral magnetic resonance imaging showed the characteristic features of brain abscess in the left frontal lobe. Cardiologic workup to exclude a right-to-left shunt showed an abnormality of the systemic venous drainage: presence of isolated left superior vena cava draining into the left atrium in the absence of coronary sinus and atrial septal defect. This anomaly is rare, because only a few other cases have been reported.

  8. Ectopic drainage from the inferior vena cava to the left atrium together with a partial anomalous pulmonary venous connection.

    PubMed

    Wu, Yuan; Xu, Shuangyue; Guo, Hongwei; Yan, Guoliang; Qi, Zhongquan; Shan, Zhonggui

    2014-07-01

    We report a case of a 44-year-old male patient with ectopic drainage from the inferior vena cava to the left atrium accompanied by partial anomalous pulmonary venous drainage. After the patient was hospitalized, his diagnosis was confirmed by Doppler echocardiography and angiography. A pericardial patch was used to divert the blood to the atrium. The surgical procedure was successful, and the patient began a rehabilitation program 8 days later. This type of ectopic drainage pattern is an unusual and infrequent clinical finding. The definitive diagnosis should be made by Doppler ultrasound combined with angiography. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Are too many inferior vena cava filters used? Controversial evidences in different clinical settings: a narrative review.

    PubMed

    Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele

    2018-03-01

    The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.

  10. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature

    PubMed Central

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-01-01

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665

  11. Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahrer, Arie; Zippel, Douglas; Garniek, Alexander

    The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavographymore » prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.« less

  12. Temporary Intraoperative Porto-Caval Shunts in Piggy-Back Liver Transplantation Reduce Intraoperative Blood Loss and Improve Postoperative Transaminases and Renal Function: A Meta-Analysis.

    PubMed

    Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K

    2016-12-01

    The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.

  13. Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli

    NASA Technical Reports Server (NTRS)

    Butler, B. D.; Morris, W. P.

    1995-01-01

    Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.

  14. Race to the Top District Competition: The Data Quality Campaign's Comments on ED's Proposed Criteria

    ERIC Educational Resources Information Center

    Data Quality Campaign, 2012

    2012-01-01

    The Data Quality Campaign (DQC) submits these comments in response to the US Department of Education's (ED) draft requirements, priorities, selection criteria, and definitions for the Race to the Top District (RTT-D) competition. DQC applauds ED for including the following components of the proposal: (1) Data is acknowledged throughout the…

  15. On-and offshore tephrostratigraphy and -chronology of the southern Central American Volcanic Arc (CAVA)

    NASA Astrophysics Data System (ADS)

    Schindlbeck, J. C.; Kutterolf, S.; Hemming, S. R.; Wang, K. L.

    2015-12-01

    Including the recently drilled CRISP sites (IODP Exp. 334&344) the deep sea drilling programs have produced 69 drill holes at 29 Sites during 9 Legs at the Central American convergent margin, where the Cocos plate subducts beneath the Caribbean plate. The CAVA produced numerous plinian eruptions in the past. Although abundant in the marine sediments, information and data regarding large late Cenozoic explosive eruptions from Costa Rica, Nicaragua, Honduras, El Salvador, and Guatemala remain very sparse and discontinuous on land. We have established a tephrostratigraphy from recent through Miocene times from the unique archive of ODP/IODP sites offshore Central America in which we identify tephra source regions by geochemical fingerprinting using major and trace element glass shard compositions. Here we present first order correlations of ­~500 tephra layers between multiple holes at a single site as well as between multiple sites. We identified ashes supporting Costa Rican (~130), Nicaraguan (17) and Guatemalan (27) sources as well as ~150 tephra layers from the Galápagos hotspot. Within our marine record we also identified well-known marker beds such as the Los Chocoyos tephra from Atitlán Caldera in Guatemala and the Tiribi Tuff from Costa Rica but also correlations to 15 distinct deposits from known Costa Rican and Nicaraguan eruptions within the last 4.1 Ma. These correlations, together with new radiometric age dates, provide the base for an improved tephrochronostratigraphy in this region. Finally, the new marine record of explosive volcanism offshore southern CAVA provides insights into the eruptive history of long-living volcanic complexes (e.g., Barva, Costa Rica) and into the distribution and frequency of large explosive eruptions from the Galápagos hotspot. The integrated approach of Ar/Ar age dating, correlations with on land deposits from CAVA, biostratigraphic ages and sediment accumulation rates improved the age models for the drilling sites.

  16. Indications, complications and outcomes of elderly patients undergoing retrievable inferior vena cava filter placement.

    PubMed

    Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef

    2017-10-01

    The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P < 0.001). Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.

  17. Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Henshaw, W D; Wang, S L

    To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flowmore » in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating/stagnant flow with very low shear stress that may be thrombogenic.« less

  18. Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.

    PubMed

    Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech

    2016-06-01

    Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.

  19. Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy

    PubMed Central

    Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.

    2004-01-01

    Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular reconstructions were patent at last follow-up. With median follow-up of 26 months, 5 patients have died of recurrent malignancy at 44, 40, 32, 26, and 24 months, while an additional patient is alive with disease at 31 months. Actuarial 1-, 3-, and 5-year survivals were 85%, 60%, and 33%, respectively. Conclusions: IVC involvement by hepatic malignancy does not necessarily preclude resection. Liver resection with reconstruction of the inferior vena cava can be performed in selected cases. The increased risk associated with the procedure appears to be balanced by the possible benefits, particularly when the lack of alternative curative approaches is considered. PMID:15082976

  20. Organizational Governance and the Production of Academic Quality: Lessons from Two Top U.S. Research Universities

    ERIC Educational Resources Information Center

    Thoenig, Jean-Claude; Paradeise, Catherine

    2014-01-01

    Does organizational governance contribute to academic quality? Two top research universities are observed in-depth: Berkeley and the MIT. Three key factors are listed that help generate consistent and lasting high performance. Priority is allocated to self-evaluation and to the development of talent. Values and norms such as community membership,…

  1. Outcomes of Stent Placement for Chronic Occlusion of a Filter-bearing Inferior Vena Cava in Patients with Severe Post-thrombotic Syndrome.

    PubMed

    Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M

    2016-12-01

    To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Design-of-Experiments Approach to Improving Inferior Vena Cava Filter Retrieval Rates.

    PubMed

    Makary, Mina S; Shah, Summit H; Warhadpande, Shantanu; Vargas, Ivan G; Sarbinoff, James; Dowell, Joshua D

    2017-01-01

    The association of retrievable inferior vena cava filters (IVCFs) with adverse events has led to increased interest in prompt retrieval, particularly in younger patients given the progressive nature of these complications over time. This study takes a design-of-experiments (DOE) approach to investigate methods to best improve filter retrieval rates, with a particular focus on younger (<60 years) patients. A DOE approach was executed in which combinations of variables were tested to best improve retrieval rates. The impact of a virtual IVCF clinic, primary care physician (PCP) letters, and discharge instructions was investigated. The decision for filter retrieval in group 1 was determined solely by the referring physician. Group 2 included those patients prospectively followed in an IVCF virtual clinic in which filter retrieval was coordinated by the interventional radiologist when clinically appropriate. In group 3, in addition to being followed through the IVCF clinic, each patient's PCP was faxed a follow-up letter, and information regarding IVCF retrieval was added to the patient's discharge instructions. A total of 10 IVCFs (8.4%) were retrieved among 119 retrievable IVCFs placed in group 1. Implementation of the IVCF clinic in group 2 significantly improved the retrieval rate to 25.3% (23 of 91 retrievable IVCFs placed, P < .05). The addition of discharge instructions and PCP letters to the virtual clinic (group 3) resulted in a retrieval rate of 33.3% (17 of 51). The retrieval rates demonstrated more pronounced improvement when examining only younger patients, with retrieval rates of 11.3% (7 of 62), 29.5% (13 of 44, P < .05), and 45.2% (14 of 31) for groups 1, 2, and 3, respectively. DOE methodology is not routinely executed in health care, but it is an effective approach to evaluating clinical practice behavior and patient quality measures. In this study, implementation of the combination of a virtual clinic, PCP letters, and discharge instructions improved retrieval rates compared with a virtual clinic alone. Quality improvement strategies such as these that augment patient and referring physician knowledge on interventional radiologic procedures may ultimately improve patient safety and personalized care. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Blood Pool Segmentation Results in Superior Virtual Cardiac Models than Myocardial Segmentation for 3D Printing.

    PubMed

    Farooqi, Kanwal M; Lengua, Carlos Gonzalez; Weinberg, Alan D; Nielsen, James C; Sanz, Javier

    2016-08-01

    The method of cardiac magnetic resonance (CMR) three-dimensional (3D) image acquisition and post-processing which should be used to create optimal virtual models for 3D printing has not been studied systematically. Patients (n = 19) who had undergone CMR including both 3D balanced steady-state free precession (bSSFP) imaging and contrast-enhanced magnetic resonance angiography (MRA) were retrospectively identified. Post-processing for the creation of virtual 3D models involved using both myocardial (MS) and blood pool (BP) segmentation, resulting in four groups: Group 1-bSSFP/MS, Group 2-bSSFP/BP, Group 3-MRA/MS and Group 4-MRA/BP. The models created were assessed by two raters for overall quality (1-poor; 2-good; 3-excellent) and ability to identify predefined vessels (1-5: superior vena cava, inferior vena cava, main pulmonary artery, ascending aorta and at least one pulmonary vein). A total of 76 virtual models were created from 19 patient CMR datasets. The mean overall quality scores for Raters 1/2 were 1.63 ± 0.50/1.26 ± 0.45 for Group 1, 2.12 ± 0.50/2.26 ± 0.73 for Group 2, 1.74 ± 0.56/1.53 ± 0.61 for Group 3 and 2.26 ± 0.65/2.68 ± 0.48 for Group 4. The numbers of identified vessels for Raters 1/2 were 4.11 ± 1.32/4.05 ± 1.31 for Group 1, 4.90 ± 0.46/4.95 ± 0.23 for Group 2, 4.32 ± 1.00/4.47 ± 0.84 for Group 3 and 4.74 ± 0.56/4.63 ± 0.49 for Group 4. Models created using BP segmentation (Groups 2 and 4) received significantly higher ratings than those created using MS for both overall quality and number of vessels visualized (p < 0.05), regardless of the acquisition technique. There were no significant differences between Groups 1 and 3. The ratings for Raters 1 and 2 had good correlation for overall quality (ICC = 0.63) and excellent correlation for the total number of vessels visualized (ICC = 0.77). The intra-rater reliability was good for Rater A (ICC = 0.65). Three models were successfully printed on desktop 3D printers with good quality and accurate representation of the virtual 3D models. We recommend using BP segmentation with either MRA or bSSFP source datasets to create virtual 3D models for 3D printing. Desktop 3D printers can offer good quality printed models with accurate representation of anatomic detail.

  4. Successful repair of injured hepatic veins and inferior vena cava following blunt traumatic injury, by using cardiopulmonary bypass and hypothermic circulatory arrest.

    PubMed

    Kaoutzanis, Christodoulos; Evangelakis, Erotokritos; Kokkinos, Chrysostomos; Kaoutzanis, Gavriel

    2011-01-01

    Traumatic injury to the retrohepatic veins continues to carry high mortality rates. In the last few decades various management strategies have been proposed. However, treatment of such injuries still remains highly variable and technically challenging due to the surgically inaccessible location of these vessels and the consequent difficulty controlling bleeding. We report a successful repair of complete transection of the two main extraparenchymal hepatic veins and laceration of the retrohepatic inferior vena cava using cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA) following blunt abdominal trauma. Immediate CPB with or without HCA can be life-saving and should be considered for patients with complex isolated retrohepatic venous injuries.

  5. [Intensity of lipid peroxidation and antioxidant enzyme activity in arterial and venous walls during hypervitaminosis D].

    PubMed

    Harbuzova, V Iu

    2002-01-01

    The intensity of the lipid peroxydation (LPO) and the antioxidant enzyme activity (superoxide dismutase, glutathione peroxydase and catalase) on injecting vitamin D in high doses (10,000 U/kg) was examined in the arterial and venous walls of rabbits. The increase in the amount of the intermediate and final LPO products has been found in the vessels of all types. The lowest intensity of LPO was noted in the vena cava. The decrease in the antioxidant activity has been revealed. But vena cava inferior was the exception because the activity of all studied antioxidant enzymes grew in its wall. This increase is likely to be one of the reasons for vena resistance to the action of damaging factors.

  6. Race to the Top--Early Learning Challenge (RTT-ELC): Descriptive Study of Tiered Quality Rating and Improvement Systems (TQRIS). Master Data Collection Protocol

    ERIC Educational Resources Information Center

    Mathematica Policy Research, Inc., 2015

    2015-01-01

    This master data collection protocol describes the data that Mathematica collected for the Race to the Top-Early Learning Challenge Study of Tiered Quality Rating and Improvement Systems. This study was conducted for the Department of Education's Institute of Education Sciences. The data were collected from reviews of applications, documents, and…

  7. Case report on the non-operative management of a retrievable inferior vena cava filter perforating the duodenum.

    PubMed

    Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R

    2017-01-01

    Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.

  8. Infrahepatic vena cavocavostomy, a modification of the piggyback technique for liver transplantation.

    PubMed

    Khanmoradi, Kamran; Defaria, Werviston; Nishida, Seigo; Levi, David; Kato, Tomoaki; Moon, Jang; Selvaggi, Gennaro; Tzakis, Andreas

    2009-05-01

    We describe our experience with a modification of the piggyback (PB) technique for orthotopic liver transplantation in which the donor infrahepatic vena cava is used as the venous outflow tract. From May 1997 to January 2006, a total of 109 cases using this technique were performed in 101 patients. Collected data included recipient demographics and diagnosis, warm ischemia time, use of venovenous bypass or temporary portacaval shunt and complications related to the venous outflow and graft, and patient survival. Data were compared with the patients undergoing standard PB technique during the same period. The reasons for using the technique were grouped according to whether there was a problem with the recipient hepatic veins or a concern about the length or diameter of the donor suprahepatic vena cava. These included the presence of a transjugular intrahepatic portosystemic shunt (eight cases), retransplantation (22 cases), thin-walled, friable hepatic veins (32 cases), Budd-Chiari syndrome (two cases), domino liver procurement (six cases), reduced or split liver grafts (five cases), and graft inferior vena cava to recipient hepatic veins size discrepancy (34 cases). There was no graft loss. The warm ischemia time was 39.65 minutes compared with 37 minutes in the standard PB group. The long-term graft and patient survival rates were similar in the two groups. Infrahepatic vena cavocavostomy is a useful variation of the standard PB technique.

  9. Sharp Central Venous Recanalization by Means of a TIPS Needle

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Honnef, Dagmar, E-mail: honnef@rad.rwth-aachen.de; Wingen, Markus; Guenther, Rolf W.

    The purpose of this study was to perform an alternative technique for recanalization of a chronic occlusion of the left brachiocephalic vein that could not be traversed with a guidewire. Restoration of a completely thrombosed left brachiocephalic vein was attempted in a 76-year-old male hemodialysis patient with massive upper inflow obstruction, massive edema of the face, neck, shoulder, and arm, and occlusion of the stented right brachiocephalic vein/superior vena cava. Vessel negotiation with several guidewires and multipurpose catheters proved unsuccessful. The procedure was also non-viable using a long, 21G puncture needle. Puncture of the superior vena cava (SVC) at themore » distal circumference of the stent in the right brachiocephalic vein/superior vena cava, however, was feasible with a transjugular intrahepatic portosystemic shunt (TIPS) set under biplanar fluoroscopy using the distal end of the right brachiocephalic vein as a target, followed by balloon dilatation and partial extraction of thrombotic material of the left brachiocephalic vein with a wire basket. Finally, two overlapping stents were deployed to avoid early re-occlusion. Venography demonstrated complete vessel patency with free contrast media flow via the stents into the SVC, which was reconfirmed in follow-up examinations. Immediate clinical improvement was observed. Venous vascular recanalization of chronic venous occlusion by means of a TIPS needle is feasible as a last resort under certain precautions.« less

  10. Assessing the influence of component processing and donor characteristics on quality of red cell concentrates using quality control data.

    PubMed

    Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P

    2016-07-01

    Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.

  11. Improvement in top-gate MoS2 transistor performance due to high quality backside Al2O3 layer

    NASA Astrophysics Data System (ADS)

    Bolshakov, Pavel; Zhao, Peng; Azcatl, Angelica; Hurley, Paul K.; Wallace, Robert M.; Young, Chadwin D.

    2017-07-01

    A high quality Al2O3 layer is developed to achieve high performance in top-gate MoS2 transistors. Compared with top-gate MoS2 field effect transistors on a SiO2 layer, the intrinsic mobility and subthreshold slope were greatly improved in high-k backside layer devices. A forming gas anneal is found to enhance device performance due to a reduction in the charge trap density of the backside dielectric. The major improvements in device performance are ascribed to the forming gas anneal and the high-k dielectric screening effect of the backside Al2O3 layer. Top-gate devices built upon these stacks exhibit a near-ideal subthreshold slope of ˜69 mV/dec and a high Y-Function extracted intrinsic carrier mobility (μo) of 145 cm2/V.s, indicating a positive influence on top-gate device performance even without any backside bias.

  12. Side-to-side cavocavostomy with an endovascular stapler: Rescue technique for severe hepatic vein and/or inferior vena cava outflow obstruction after liver transplantation using the piggyback technique.

    PubMed

    Quintini, Cristiano; Miller, Charles M; Hashimoto, Koji; Philip, Ding; Uso, Teresa Diago; Aucejo, Federico; Kelly, Dympna; Winans, Charles; Eghtesad, Bijan; Vogt, David; Fung, John

    2009-01-01

    Venous outflow obstruction is a rare but potentially lethal complication after orthotopic liver transplantation (OLT) with the "piggyback" technique. Therapeutic options include angioplasty with or without stent placement, surgical reconstruction of the venous anastomosis, and retransplantation. Surgical options are technically very challenging and the outcomes discouraging. We describe here two cases of venous outflow obstruction in recipients of piggyback liver grafts, one involving both the vena cava and hepatic veins and the other affecting only hepatic vein outflow. Both patients were treated successfully with side-to-side cavo-cavostomy using an endovascular (endo-GIA) stapler. This novel technique is fast and effective in resolving the outflow obstruction. Copyright 2008 AASLD.

  13. Transfemoral Filter Eversion Technique following Unsuccessful Retrieval of Option Inferior Vena Cava Filters: A Single Center Experience.

    PubMed

    Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A

    2017-06-01

    This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  14. Bromine release during Plinian eruptions along the Central American Volcanic Arc

    NASA Astrophysics Data System (ADS)

    Hansteen, T. H.; Kutterolf, S.; Appel, K.; Freundt, A.; Perez-Fernandez, W.; Wehrmann, H.

    2010-12-01

    Volcanoes of the Central American Volcanic Arc (CAVA) have produced at least 72 highly explosive eruptions within the last 200 ka. The eruption columns of all these “Plinian” eruptions reached well into the stratosphere such that their released volatiles may have influenced atmospheric chemistry and climate. While previous research has focussed on the sulfur and chlorine emissions during such large eruptions, we here present measurements of the heavy halogen bromine by means of synchrotron radiation induced micro-XRF microanalysis (SR-XRF) with typical detection limits at 0.3 ppm (in Fe rich standard basalt ML3B glass). Spot analyses of pre-eruptive glass inclusions trapped in minerals formed in magma reservoirs were compared with those in matrix glasses of the tephras, which represent the post-eruptive, degassed concentrations. The concentration difference between inclusions and matrix glasses, multiplied by erupted magma mass determined by extensive field mapping, yields estimates of the degassed mass of bromine. Br is probably hundreds of times more effective in destroying ozone than Cl, and can accumulate in the stratosphere over significant time scales. Melt inclusions representing deposits of 22 large eruptions along the CAVA have Br contents between 0.5 and 13 ppm. Br concentrations in matrix glasses are nearly constant at 0.4 to 1.5 ppm. However, Br concentrations and Cl/Br ratios vary along the CAVA. The highest values of Br contents (>8 ppm) and lowest Cl/Br ratios (170 to 600) in melt inclusions occur across central Nicaragua and southern El Salvador, and correlate with bulk-rock compositions of high Ba/La > 85 as well as low La/Yb <5. Thus we observe the maximum magmatic Br-concentrations in the segements of the arc. where the input of sediment and water into the subduction system is largest and the melting column is longest. The largest eruptive emissions of Br into the atmosphere, however, occurred in Guatemala due to the large magnitude of eruptions. The most prominent example is the 84 ka Los Chocoyos eruption from Atitlán Caldera, which discharged 700 kilotons of Br. On average, each of the remaining 21 CAVA eruptions studied have discharged c.100 kilotons of bromine. During the past 200 ka, CAVA volcanoes have emitted a cumulative mass of 3.2 Mt of Br through highly explosive eruptions. There are six periods in the past (c. 2ka, 6ka, 25ka, 40ka, 60ka, 75ka) when up to four larger eruptions occurred within only several hundred years. The heavy halogen release of these eruptions may have had a cumulative effect on the atmosphere which is presently investigated by climate/atmosphere models based on our analyses as input data.

  15. Cardiopulmonary Syndromes (PDQ®)—Health Professional Version

    Cancer.gov

    Cardiopulmonary syndromes (dyspnea, chronic cough, pleural and pericardial effusion, and superior vena cava syndrome) can occur in certain cancers. Get comprehensive information about these syndromes in this summary for clinicians.

  16. Sample size determination for bibliographic retrieval studies

    PubMed Central

    Yao, Xiaomei; Wilczynski, Nancy L; Walter, Stephen D; Haynes, R Brian

    2008-01-01

    Background Research for developing search strategies to retrieve high-quality clinical journal articles from MEDLINE is expensive and time-consuming. The objective of this study was to determine the minimal number of high-quality articles in a journal subset that would need to be hand-searched to update or create new MEDLINE search strategies for treatment, diagnosis, and prognosis studies. Methods The desired width of the 95% confidence intervals (W) for the lowest sensitivity among existing search strategies was used to calculate the number of high-quality articles needed to reliably update search strategies. New search strategies were derived in journal subsets formed by 2 approaches: random sampling of journals and top journals (having the most high-quality articles). The new strategies were tested in both the original large journal database and in a low-yielding journal (having few high-quality articles) subset. Results For treatment studies, if W was 10% or less for the lowest sensitivity among our existing search strategies, a subset of 15 randomly selected journals or 2 top journals were adequate for updating search strategies, based on each approach having at least 99 high-quality articles. The new strategies derived in 15 randomly selected journals or 2 top journals performed well in the original large journal database. Nevertheless, the new search strategies developed using the random sampling approach performed better than those developed using the top journal approach in a low-yielding journal subset. For studies of diagnosis and prognosis, no journal subset had enough high-quality articles to achieve the expected W (10%). Conclusion The approach of randomly sampling a small subset of journals that includes sufficient high-quality articles is an efficient way to update or create search strategies for high-quality articles on therapy in MEDLINE. The concentrations of diagnosis and prognosis articles are too low for this approach. PMID:18823538

  17. Cardiopulmonary Syndromes (PDQ®)—Patient Version

    Cancer.gov

    Expert-reviewed information summary about common conditions that produce chest symptoms. The cardiopulmonary syndromes addressed in this summary are cancer-related dyspnea, malignant pleural effusion, pericardial effusion, and superior vena cava syndrome.

  18. Guide wire entrapment by inferior vena cava filters: an experimental study.

    PubMed

    Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F

    2005-09-01

    In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.

  19. Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: a safe alternative to surgical repair.

    PubMed

    Chen, Qiang; Chen, Liang-Wan; Cao, Hua; Zhang, Gui-Can; Chen, Dao-Zhong; Zhang, Hui

    2011-03-01

    Our objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency. From January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect. The procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001). Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging. Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.

  20. Why Quality of Work Life Doesn't Always Mean Quality.

    ERIC Educational Resources Information Center

    Cohen, Deborah Shaw

    1981-01-01

    From participatory management to autonomous work groups, the quality of work life movement has made an impact on U.S. corporations. To make the quality of work life connection, commitment must originate with top management. (Author)

  1. Informed-Proteomics: open-source software package for top-down proteomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Jungkap; Piehowski, Paul D.; Wilkins, Christopher

    Top-down proteomics involves the analysis of intact proteins. This approach is very attractive as it allows for analyzing proteins in their endogenous form without proteolysis, preserving valuable information about post-translation modifications, isoforms, proteolytic processing or their combinations collectively called proteoforms. Moreover, the quality of the top-down LC-MS/MS datasets is rapidly increasing due to advances in the liquid chromatography and mass spectrometry instrumentation and sample processing protocols. However, the top-down mass spectra are substantially more complex compare to the more conventional bottom-up data. To take full advantage of the increasing quality of the top-down LC-MS/MS datasets there is an urgent needmore » to develop algorithms and software tools for confident proteoform identification and quantification. In this study we present a new open source software suite for top-down proteomics analysis consisting of an LC-MS feature finding algorithm, a database search algorithm, and an interactive results viewer. The presented tool along with several other popular tools were evaluated using human-in-mouse xenograft luminal and basal breast tumor samples that are known to have significant differences in protein abundance based on bottom-up analysis.« less

  2. Cardiopulmonary Syndromes (PDQ®)—Health Professional Version

    Cancer.gov

    Expert-reviewed information summary about common conditions that produce chest symptoms. The cardiopulmonary syndromes addressed in this summary are cancer-related dyspnea, malignant pleural effusion, pericardial effusion, and superior vena cava syndrome.

  3. Mapping the Medical Literature for High Quality Studies and Reviews for Age-specific Clinical Specialties

    PubMed Central

    Stevens, Adrienne L.; Wilczynski, Nancy L.; McKibbon, K. Ann; Haynes, R. Brian

    2001-01-01

    Objective: To identify a journal subset that publishes reports of high quality studies and reviews relating to age-specific clinical specialties, such as pediatrics and geriatrics. Design: Handsearch of 172 journals using explicit criteria to determine methodologic quality for generating evidence for clinical practice. Main outcome measure: Frequency of high quality articles and their top yielding journals. Results: Between 17% and 33% of articles published in age-specific specialties are of high quality for clinical use. Top yielding journals for the specialties ranged from 16 to 130. Conclusion: Handsearch of the clinical literature for the year 2000 reveals that high quality articles for some age-specific specialties are concentrated in a small subset of journals (eg, obstetrics), whereas articles for other specialties are widely scattered among a large number of journals (eg, adult medicine).

  4. Thrombotic complications and tip position of transjugular chronic dialysis catheter scheduled into superior vena cava

    PubMed Central

    Li, Whenzheng; Li, Fang; Wang, He; Long, Xueying; Ghimire, Obin; Pei, Yigang; Xiao, Xiangcheng; Ning, Jianping

    2017-01-01

    Abstract Background: Catheter-related thrombotic complications(TCs) can occur during the long term use of a chronic dialysis catheter (CDC), including fibrin sheath (FS), mural thrombosis (MT), venous thrombosis (VT), and intraluminal clots (IC), which has not been reported with MRI. The aim of our study was to evaluate the determination of catheter tip position (TP) and resolution of TCs in patients with transjugular CDC scheduled into the superior vena cava using high resolution magnetic resonance cholangiopancreatography (HR-MRCP) and T2-weighted imaging (HR-T2WI). Methods: The study protocol was approved by the local Research Ethics Committee. Informed consent was obtained from all patients. In total, 41 consecutively enrolled transjugular CDC patients with suspected catheter dysfunction were scanned with HRMRCP and HR-T2WI. The distance from the top to the tip of the catheter and the presence and nature of catheter TCs were assessed by 2 experienced radiologists. Chest x-ray was taken within 1 to 2 days and CDC was withdrawn within 3 to 10 days from those patients with TCs identified by HR-MRI. Results: A total of 38 subjects successfully underwent HR-MRI, including 13 normal and 25 with TCs (fibrin sheath [FS]: n = 21, mural thrombosis [MT]: n = 7, venous thrombosis [VT]: n = 3, intraluminal clots [IC]: n = 4). There was no significant difference between HR-MRCP and chest x-ray in catheter TP determination (P = .124). Normal catheter appeared as “double eyes” on HR-T2WI and “double tracks” on HR-MRCP. TCs appeared as follows: FS displayed as a “thin ring” (<1mm) around the catheter, MT as patchy hyperintensity and VT as a “thick ring” (>5mm) on HR-T2WI. Unilateral IC appeared as a “single eye” on HR-T2WI and a “single track” on HR-MRCP (n = 3). Bilateral IC appeared as neither “eye” nor “track” (n = 1). Catheter withdrawal confirmed FS (n = 16), MT (n = 6), VT (n = 1), and IC (n = 4). Conclusion: HR-MRCP and HR-T2WI are promising methods for visualizing TP and TCs in CDC patients, and are helpful in adjusting the treatment plan and avoiding the risk of pulmonary embolism. PMID:28658104

  5. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    PubMed

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  6. Pheochromocytoma with inferior vena cava thrombosis: An unusual association.

    PubMed

    Kota, Sunil K; Kota, Siva K; Jammula, Sruti; Meher, Lalit K; Modi, Kirtikumar D

    2012-04-01

    Pheochromocytomas have been described in association with vascular abnormalities like renal artery stenosis. A 48-year-old man was admitted to our hospital with the complaints of headache, sweating, anxiety, dizziness, nausea, vomiting and hypertension. For last several days, he was having a dull aching abdominal pain. Abdominal computed tomography (CT) revealed the presence of a left adrenal pheochromocytoma. An inferior vena cava (IVC) venogram via the right jugular vein demonstrated occlusion of the IVC inferior to the right atrium. Surgical removal of pheochromocytoma was done, followed by anticoagulant treatment for IVC thrombosis, initially with subcutaneous low molecular weight heparin, and then with oral warfarin, resulting in restoration of patency. To the best of our knowledge, the occurrence of pheochromocytoma in IVC thrombosis has not been reported so far from India. Possible mechanisms of such an involvement are discussed.

  7. 2D array transducers for real-time 3D ultrasound guidance of interventional devices

    NASA Astrophysics Data System (ADS)

    Light, Edward D.; Smith, Stephen W.

    2009-02-01

    We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.

  8. Modulation of key reactions of the catecholamine metabolism by extracts from Eschscholtzia californica and Corydalis cava.

    PubMed

    Kleber, E; Schneider, W; Schäfer, H L; Elstner, E F

    1995-02-01

    Aqueous-alcoholic extracts from Eschscholtzia californica inhibit the enzymatic degradation of catecholamines as well as the synthesis of adrenaline, whereas aqueous-ethanolic extracts from Corydalis cava enhance the chemical oxidation of adrenaline and the synthesis of melanine from dihydroxyphenylalanine (DOPA). Both extracts dramatically shorten the lag phase in the catalysis of phenolase probably due to their o-diphenol content, where the Corydalis extracts are 10 times more active than the Eschscholtzia preparations. Dopamine beta-hydroxylase and monoamine oxidase (MAO-B) are especially inhibited by Eschscholtzia extracts. Diamine oxidases are inhibited by both preparations to a similar extent. The results of this study may be interpreted as a cooperative function of the two preparations in establishing and preserving high catecholamine levels thus explaining their sedative, antidepressive and hypnotic activities.

  9. Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.

    PubMed

    Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin

    2016-12-01

    Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Implantation of a cardiac resynchronization therapy-defibrillator device in a patient with persistent left superior vena cava.

    PubMed

    Atar, İlyas; Karaçağlar, Emir; Özçalık, Emre; Özin, Bülent; Müderrisoğlu, Haldun

    2015-06-01

    Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CRT-D) implantation. A PLSVC draining via a dilated coronary sinus into an enlarged right atrium was diagnosed. First, an active-fixation right ventricular lead was inserted into the right atrium through the PLSVC. The stylet was preshaped to facilitate its passage to the right ventricular apex. An atrial lead was positioned on the right atrium free wall, and an over-the-wire coronary sinus lead deployed to a stable position. CRT-D implantation procedure was successfully completed.

  11. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature.

    PubMed

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-06-04

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. CT of inferior vena cava filters: normal presentations and potential complications.

    PubMed

    Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man

    2015-12-01

    With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.

  13. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less

  14. Successful management of multiple permanent pacemaker complications – infection, 13 year old silent lead perforation and exteriorisation following failed percutaneous extraction, superior vena cava obstruction, tricuspid valve endocarditis, pulmonary embolism and prosthetic tricuspid valve thrombosis

    PubMed Central

    Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir

    2009-01-01

    A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701

  15. Absent Inferior Vena Cava Leading to Recurrent Lower Extremity Deep Vein Thrombosis in a United States Marine.

    PubMed

    Kim, Sang; Kunkel, Scott; Browske, Kristin

    2018-01-01

    Anomalies of the inferior vena cava (AIVC) are rare but well-recognized anatomic abnormalities that can lead to clinically significant deep vein thrombosis (DVT) in a subset of otherwise healthy patients. This report illustrates an uncommon congenital anomaly that military clinicians should consider when evaluating unprovoked DVT in young patients. Single case report and literature review. We describe a case of a 24-yr-old United States Marine who presented with abdominal pain for 2 wk. After conservative therapy failed, a contrast-enhanced abdominal computed tomography (CT) scan was performed. The CT scan revealed an absent inferior vena cava with evidence of right venous thrombophlebitis. We include four contrast-enhanced helical CT scans that illustrate this phenomenon. Due to the lack of available studies and data, we do not know the relative risk of DVT in patients with AIVC. However, the literature review suggests that there is a pro-thrombogenic effect of this congenital anomaly. Clinicians should include AIVC in their differential when treating young, otherwise healthy patients with unprovoked DVT. This population is much more likely to have an AIVC than the general population. In addition to thrombophilia markers, a contrast-enhanced CT scan should be considered as part of the initial workup. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  16. Definitions of Digestive Terms

    MedlinePlus

    ... usual, and loose stools. May be chronic or acute (Ogilvie's syndrome). Top of Page Q Quality of life Perception of ability to meet daily needs, physical activities, well-being. Top of Page R Radiation proctitis Bleeding, mucous and bloody discharge, spasm of ...

  17. Progress and Challenges in Developing Tiered Quality Rating and Improvement Systems (TQRIS) in the Round 1 Race to the Top-Early Learning Challenge (RTT-ELC) States. NCEE 2018-4003

    ERIC Educational Resources Information Center

    Kirby, Gretchen; Caronongan, Pia; Esposito, Andrea Mraz; Murphy, Lauren; Shoji, Megan; Del Grosso, Patricia; Kiambuthi, Wamaitha; Clark, Melissa; Dragoset, Lisa

    2017-01-01

    This report focuses on the progress made and challenges faced by the nine states in achieving the first three objectives for which they were held accountable for use of their Race to the Top Early Learning Challenge (RTTELC) funds. It discusses discrete findings related to these objectives in relevant chapters of the report: Tiered Quality Rating…

  18. [New Insights into Maternal Cardiopulmonary Resuscitation--Significance of Simulation Research and Training].

    PubMed

    Komasawa, Nobuyasu; Fujiwara, Shunsuke; Majima, Nozomi; Minami, Toshiaki

    2015-08-01

    Pregnancy-related mortality, estimated to occur in approximately 1: 50,000 deliveries, is rare in developed countries. The 2010 American Heart Association (AHA) Guidelines for Resuscitation emphasize the importance of high-quality chest compression as a key determinant of successful cardiopulmonary resuscitation. During pregnancy, the uterus can compress the inferior vena cava, impeding venous return and thereby reducing stroke volume and cardiac output. To maximize the effectiveness of chest compressions in pregnancy, the AHA guidelines recommend the 27-30 degrees left-lateral tilt (LLT) position. When CPR is performed on parturients in the LLT position, chest compressions will probably be more effective if performed with the operator standing on the left side of the patient. The videolaryngoscope Pentax-AWS Airwayscope (AWS) was found to be an effective tool for airway management during chest compressions in 27 LLT simulations, suggesting that the AWS may be a useful device for airway management during maternal resuscitation.

  19. Deep venous thrombosis and postthrombotic syndrome: invasive management.

    PubMed

    Comerota, A J

    2015-03-01

    Invasive management of postthrombotic syndrome encompasses the two ends of the deep vein thrombosis spectrum, patients with acute iliofemoral deep vein thrombosis and those with chronic postthrombotic iliofemoral venous obstruction. Of all patients with acute deep vein thrombosis, those with involvement of the iliofemoral segments have the most severe chronic postthrombotic morbidity. Catheter-based techniques now permit percutaneous treatment to eliminate thrombus, restore patency, potentially maintain valvular function, and improve quality of life. Randomized trial data support an initial treatment strategy of thrombus removal. Failure to eliminate acute thrombus from the iliofemoral system leads to chronic postthrombotic obstruction of venous outflow. Debilitating chronic postthrombotic symptoms of the long-standing obstruction of venous outflow can be reduced by restoring unobstructed venous drainage from the profunda femoris vein to the vena cava. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Legacy of top-down herbivore pressure ricochets back up multiple trophic levels in forest canopies over 30 years

    Treesearch

    Tim Nuttle; Ellen H. Yerger; Scott H. Stoleson; Todd E. Ristau

    2011-01-01

    Removal of top-down control on herbivores can result in a trophic cascade where herbivore pressure on plants results in changes in plant communities. These altered plant communities are hypothesized to exert bottom-up control on subsequent herbivory via changes in plant quality or productivity. But it remains untested whether top-down perturbation causes long term...

  1. Total Quality Management in Education. Second Edition.

    ERIC Educational Resources Information Center

    Sallis, Edward

    Quality is at the top of most agendas, and improving quality is probably the most important task facing any institution. In addition, quality is difficult to define or measure. This book, the second edition of "Total Quality Management in Education," introduces the key concepts of Total Quality Management (TQM) and demonstrates how they…

  2. A hospital's teamwork and CQI advance shared vision, interdependence among top managers. Interview by Paula Eubanks.

    PubMed

    Biltz, J; Mild, L

    1992-09-20

    As quality improvement programs are initiated in growing numbers of hospitals, senior executives in those hospitals find themselves addressing a range of issues: team building, leadership and interpersonal interaction. CEO Jim Biltz and nurse executive Linda Mild of 760-bed HCA Wesley Medical Center, Wichita, KS, tell Hospitals Staff Editor Paula Eubanks how their participative management style and the hospital's continuous quality improvement (CQI) initiative have fostered new levels of teamwork and shared vision among the institution's top managers.

  3. What Top Management Expects from the Communicator.

    ERIC Educational Resources Information Center

    Fegley, Robert L.

    Top corporate management requires communications departments that maintain credibility with the public by developing the following qualities: integrity established through consistent and honest messages; accuracy based on solid research; authority derived from an understanding of the subject and from drawing on appropriate expertise; a…

  4. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  5. Double-lumen catheter in the right jugular vein induces two sub-endothelial abscesses in an unusual place, the transition between the superior vena cava and the right atrium: a case report

    PubMed Central

    2014-01-01

    Endocarditis is a type of infection that is common in internal medicine wards and in haemodialysis clinics. The location that is most affected are the heart valves. Herein, we report a case of an uncommon abscess, a sub-endothelial abscess between the transition of the superior vena cava and the right atrium. There were several emboli to the lung and foot, and the agent was related to Staphylococcus aureus and a double-lumen catheter. Usually, this type of abscess is located in valves, either the tricuspid valve if related to catheters or injection drug use or the mitral valve if related to other causes. An exhaustive review was made, but we found no information about the location of this abscess and the rarity of the event motivating the report of infection. PMID:25110520

  6. Catheter-Directed Thrombolysis of Acute Deep Vein Thrombosis in the Lower Extremity of a Child with Interrupted Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Ozkan, Ugur; Tercan, Fahri

    2007-04-15

    We present the case of a 14-year-old girl who developed acute deep vein thrombosis (DVT) in her right lower extremity. Laboratory testing revealed protein S deficiency, and the patient's father also had this abnormality with a history of lower extremity DVT. Manual thromboaspiration followed by catheter-directed thrombolysis resulted in total clearance of all thrombi. Computed tomography and later venography revealed an interrupted inferior vena cava. Catheter-directed thrombolysis is an established treatment for adults with acute DVT. To the best of our knowledge, this report is the first to describe catheter-directed thrombolysis in a pediatric patient with lower extremity DVT. Ourmore » results suggest that catheter-directed thrombolysis is safe and effective for use in selected older children and adolescents with acute DVT in the lower extremity.« less

  7. Congenital cardiac malformations in relation to central venous access.

    PubMed

    Thompson, Christine

    During the third and seventh weeks of gestation, teratogenic exposure may lead to fetal abnormality such as congenital heart defects or intrauterine death. Congenital heart defects are present from birth, but may appear at any time, or only revealed postmortem. Often defects are present by degree. Some defects are life-threatening, while other, less severe conditions, may have minimal physiological impact. Left superior vena cava exists in early embryonic development, but the vessel degenerates as the cardiovascular system matures. When not associated with other malformations, an incidence of persistent left-sided superior vena cava (PLSVC) has no clinical signs or symptoms. However, it may not be as innocuous as it appears due to its association with the cyanotic defect, tetralogy of Fallot (TOF). Using a case history as an illustration it can be shown that all cases of defect or chromosomal suspicion should be documented as there may be implications for future interventions.

  8. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  9. Intravenous leiomyomatosis of the uterus with extension to the right heart

    PubMed Central

    2011-01-01

    A 42-year-old woman admitted with debilitation and engorgement both lower extremities. Transthoracic two-dimensional echocardiography, abdominal ultrasound and computerized tomography revealed a lobulated pelvic mass, a mass within right internal iliac vein, both common iliac vein, as well as the inferior vena cava, extending into the right atrium. In addition, echocardiography and abdominal ultrasound showed the tumor of right atrium and inferior vena cave has no stalk and has well-demarcated borders with the wall of right atrium and inferior vena cave. Hence, the presumptive diagnosis of IVL was made by echocardiography and abdominal ultrasound and the presumptive diagnosis of sarcoma with invasion in right internal iliac vein, both common iliac vein, the inferior vena cava, as well as the right atrium was made by multi-detector-row computerized tomography. The patient underwent a one-stage combined multidisciplinary thoraco-abdominal operation under general anaesthetic. Subsequently the pathologic report confirmed IVL. PMID:21943238

  10. Partial anomalous pulmonary venous drainage. A novel approach to repair.

    PubMed

    Hanhan, U A; Moodie, D S; Gill, C C; Sterba, R; Currie, P; Stewart, R

    1989-01-01

    Isolated partial anomalous pulmonary venous drainage with an intact atrial septum is a rare finding. The authors describe their experience with three patients (ages 9, 37, and 54 years), with partial anomalous pulmonary venous connection to the superior vena cava, right atrium, and inferior vena cava, who underwent extracardiac conduit repair of this anomaly. In all three patients, a synthetic Gortex graft was used for reconstruction of the venous pathways to the left atrium. The follow-up period ranged from 10 to 82 months (mean, 42 months). All three patients were evaluated with intravenous digital angiography, transesophageal echocardiography, or both at 10, 33, and 82 months postoperatively. Patency of the grafts with no evidence of obstruction and excellent pulmonary venous flow was shown. This surgical technique is an excellent option for correction of this anomaly, and intravenous digital subtraction angiography is a useful diagnostic tool during the postoperative period to evaluate patency of the repair.

  11. Phlegmasia Caerulea Dolens in a Patient With an Inferior Vena Cava Filter: Treatment of Massive Iliocaval Thrombosis Using Local Intravenous Catheter-Directed Thrombolysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cookson, Daniel, E-mail: danielthomascookson@yahoo.co.uk; Caldwell, Stuart, E-mail: stuart.caldwell@middlemore.co.nz

    Phlegmasia caerulea dolens (PCD) is a potentially disastrous complication of inferior vena cava filter insertion, and its optimum management has not been clearly established. We present a case report of a patient with pulmonary embolism and acute adrenal haemorrhage who developed PCD secondary to massive iliocaval thrombosis after insertion of a Cook Celect removable filter. Local intravenous catheter-directed thrombolysis (CDT), followed by systemic anticoagulation, achieved limb salvage and virtual resolution of symptoms at 3 months without complications. CDT can be a successful primary treatment of filter-associated PCD and can be safe in selected patients with acute nontraumatic haemorrhage. Systemic anticoagulationmore » may subsequently restore complete venous patency and may therefore be a useful approach to postthrombolysis management of residual iliocaval thrombus when filter removal is indicated.« less

  12. Unusual case of subxiphoid uniportal VATS right upper lobectomy in a patient with interrupted inferior vena cava with azygous continuation

    PubMed Central

    Abu Akar, Firas Emad; Yang, Chenlu; Zhou, Yiming; Lin, Lei; Gonzalez-Rivas, Diego

    2017-01-01

    Interrupted IVC (also known as Azygos continuation of the inferior vena cava) is a relatively uncommon congenital condition with prevalence 1.5% (0.2–3%) of the general population (Bass et al.). Although it’s usually asymptomatic condition, splenic or cardiac abnormalities could be associated (Hardwick et al.). Incidental diagnosis during prenatal ultrasound screening or by routine imaging is the most common scenario. Special attention is required during right side thoracic procedures surgical resections in order to avoid scarifying the azygos vein that could lead to fatal results (Effler et al.). We herein report a video documented case of right upper lobectomy and mediastinal lymph node dissection for non-small cell carcinoma of lung in a patient who had interrupted hepatic segmental branch of the IVC. The procedure was performed via the subxiphoid uniportal VATS approach. PMID:29078654

  13. Total Cavopulmonary Connection for Functionally Single Ventricle without Cardiopulmonary Bypass Support.

    PubMed

    Bangash, Sohail Khan; Pathan, Iqbal Hussain; Zaki, Saad Bader

    2016-10-01

    A heart with two atriums but one ventricle, an anatomy with a unique physiology, is responsible for many creative surgical and interventional approaches in history. Different surgical techniques have been used to address this strange physiology of parallel circulation. All these attempts met with failure till the concept of Fontan circulation was described. Currently, controversy exists between multistage vs. single stage total cavopulmonary connections. Total cavopulmonary connection is the only definitive procedure performed to provide palliation for patients with complex congenital heart defects which cannot support a biventricular circulation. We report a case with tricuspid atresia with transposition of great arteries and pulmonary stenosis with persistant left-sided superior vena cava and functionally single ventricle. Patient successfully underwent single stage extra-cardiac total cavopulmonary connection. In this case, bilateral Glenn with extra-cardiac inferior vena cava to main pulmonary artery shunt was performed off-pump.

  14. Cor triatriatum dexter: A rare cause of cyanosis during neonatal period.

    PubMed

    Alghamdi, Mohammed Hussien

    2016-01-01

    Cor-triatriatum dexter is an extremely rare congenital heart defect in which there is complete persistence of the right valve of embryonic sinus venosus that results in partitioning of the right atrium into a smooth and trabeculated portion. The smooth portion receives venous blood from inferior vena cava, superior vena cava, and coronary sinus while the trabeculated portion contains the right atrial appendage and the opening of tricuspid valve. We report a 1-week-old child who presented with intermittent episodes of central cyanosis. Echocardiography, established, and bubble contrast study confirmed the diagnosis of an isolated cor-triatriatum dexter. The baby initially underwent an intervention by cardiac catheterization, which was unsuccessful in disrupting the membrane and re-direct the systemic venous flow to the right heart chambers. She subsequently had the cor-triatriatum dexter membrane resected via an uncomplicated open-heart surgery.

  15. Surgical management of renal cell cancer with tumor thrombus through an exclusive transabdominal approach.

    PubMed

    González, Javier; Angulo, J; Ciancio, G

    2011-04-01

    Renal cell cancer with tumor thrombus is present in 4-15% of cases. The prognostic significance of this entity has been object of intense debate. Nowadays, it is considered, that the presence of thrombus itself does not have a negative prognostic impact on survival rates if the thrombus could be excised satisfactorily. Complete removal of renal malignant tissue is the only curative strategy for the treatment of this kind of tumors. During the last three decades, there has been steady improvements in surgical technique and preoperative care fields that have favorably modified the surgeons' ability to safely excise these tumors. In this sense, the experience provided by multiorgan, kidney-pancreas and liver procurement and transplantation techniques led the urologists reexamine their approaches to the inferior vena cava and retroperitoneum, thus they could result useful in the always challenging resection of these complex tumors with neoplasic extension into the vena cava.

  16. Morphological study of the innervation pattern of the rabbit sinoatrial node

    NASA Technical Reports Server (NTRS)

    Roberts, L. A.; Slocum, G. R.; Riley, D. A.

    1989-01-01

    The pattern of sinoatrial (SA) node innervations in rabbit was elucidated using a newly developed highly reproducible cholinesterase/silver impregnation staining procedure which made it possible to delineate large nerves, fine processes, and ganglion cells. The SA node and dominant pacemaker sites were identified by microelectrode recording. A generalized pattern of innnervation was recognized, which includes a large ganglionic complex inferior to the SA node; two or more moderately large nerves traversing the SA node parallel to the crista terminalis; nerves entering the intercaval region from the septum, the superior vena cava, and the inferior vena cava to impinge on the SA node; and a fine network of nerve processes, which was particularly dense in the SA node. From the location and distribution of the nerves and ganglionic branches, it can be inferred that the neural network in the intercaval region is capable of performing complex modulatory and integrative functions among the structures within this region.

  17. Organizational Leadership and Adaptive Reserve in Blood Pressure Control: The Heart Health NOW Study.

    PubMed

    Henderson, Kamal H; DeWalt, Darren A; Halladay, Jacquie; Weiner, Bryan J; Kim, Jung I; Fine, Jason; Cykert, Samuel

    2018-04-01

    Our purpose was to assess whether a practice's adaptive reserve and high leadership capability in quality improvement are associated with population blood pressure control. We divided practices into quartiles of blood pressure control performance and considered the top quartile as the benchmark for comparison. Using abstracted clinical data from electronic health records, we performed a cross-sectional study to assess the association of top quartile hypertension control and (1) the baseline practice adaptive reserve (PAR) scores and (2) baseline practice leadership scores, using modified Poisson regression models adjusting for practice-level characteristics. Among 181 practices, 46 were in the top quartile, which averaged 68% or better blood pressure control. Practices with higher PAR scores compared with lower PAR scores were not more likely to reside in the top quartile of performance (prevalence ratio [PR] = 1.92 for highest quartile; 95% CI, 0.9-4.1). Similarly, high quality improvement leadership capability compared with lower capability did not predict better blood pressure control performance (PR = 0.94; 95% CI, 0.57-1.56). Practices with higher proportions of commercially insured patients were more likely than practices with lower proportions of commercially insured patients to have top quartile performance (37% vs 26%, P =.002), whereas lower proportions of the uninsured (8% vs 14%, P =.055) were associated with better performance. Our findings show that adaptive reserve and leadership capability in quality improvement implementation are not statistically associated with achieving top quartile practice-level hypertension control at baseline in the Heart Health NOW project. Our findings, however, may be limited by a lack of patient-related factors and small sample size to preclude strong conclusions. © 2018 Annals of Family Medicine, Inc.

  18. Beef customer satisfaction: cooking method and degree of doneness effects on the top sirloin steak.

    PubMed

    Savell, J W; Lorenzen, C L; Neely, T R; Miller, R K; Tatum, J D; Wise, J W; Taylor, J F; Buyck, M J; Reagan, J O

    1999-03-01

    The objective of this research was to evaluate the consumer-controlled factors of cooking method and degree of doneness on Top Choice, Low Choice, High Select, and Low Select top sirloin steaks. The in-home product test was conducted in Chicago, Houston, Philadelphia, and San Francisco. Consumers (n = 2,212) evaluated each top sirloin steak for overall like (OLIKE), tenderness (TEND), juiciness (JUIC), flavor desirability (DFLAV), and flavor intensity (IFLAV) using 23-point hedonic scales. Top sirloin steaks, regardless of city, were consistently cooked to well done or higher degrees of doneness. Dry-heat methods such as outdoor grilling, broiling, and indoor grilling were the most frequent cooking methods used. Four significant interactions existed for OLIKE: USDA quality grade x cooking method (P = .02), city x cooking method (P = .0001), city x degree of doneness (P = .01), and cooking method x degree of doneness (P = .009). Greater differences were found between cooking methods within USDA quality grade than between USDA quality grades within cooking method. Consumers in Houston rated steaks cooked by outdoor grilling higher than those from the other cities, and steaks cooked by indoor grilling were rated the highest among all cooking methods by consumers in Chicago. In Chicago, steaks cooked to more advanced degrees of doneness tended to receive higher ratings, but few differences between degrees of doneness in the other three cities were detected. For outdoor grilling, broiling, and pan-frying, the trend was for OLIKE ratings to decline as degree of doneness increased. The lowest customer satisfaction ratings tended to be given to top sirloin steaks cooked to more advanced degrees of doneness, and consumers most frequently cooked steaks to at least the well done stage. Consumer information programs or the development of postmortem techniques that would ensure acceptable palatability of top sirloin steaks may need to be developed.

  19. Winterization strategies for bulk storage of pickles

    USDA-ARS?s Scientific Manuscript database

    Cucumbers are commercially fermented and stored in bulk in outdoor open top fiberglass tanks. During winter, snow and ice that accumulates around and on top of tanks influence heat transfer in an unpredictable manner, often compromising quality. This study evaluates the performance of inexpensive an...

  20. Consumer assessment of beef palatability from four beef muscles from USDA Choice and Select graded carcasses.

    PubMed

    Hunt, M R; Garmyn, A J; O'Quinn, T G; Corbin, C H; Legako, J F; Rathmann, R J; Brooks, J C; Miller, M F

    2014-09-01

    Consumer sensory analysis was conducted to determine differences in beef palatability between two quality grade categories [Upper 2/3 (Top) Choice and Select] and four muscles [longissimus lumborum (LL), gluteus medius (GM), serratus ventralis (SV), and semimembranosus (SM)]. Generally, tenderness, flavor, and overall liking scores were more desirable for Top Choice compared to Select, regardless of muscle. Consumers rated LL as more tender (P<0.05) than SV and SM, but similar to GM (P=0.52). Overall and flavor acceptability were similar (P>0.05) between LL, GM, and SV, regardless of quality grade. Consumer overall liking was most highly correlated with flavor liking (r=0.85). When tenderness was acceptable, flavor and juiciness played a major role in determining overall acceptability. Overall liking of GM and SV from Top Choice carcasses was superior to LL from Select carcasses and comparable to LL from Top Choice carcasses. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Institutional Response to the Swedish Model of Quality Assurance.

    ERIC Educational Resources Information Center

    Nilsson, Karl-Axel; Wahlen, Staffan

    2000-01-01

    Evaluates the Swedish model of quality assurance of higher education by examining the response of institutions to 27 quality audits and 19 follow-up interviews. Discusses the relationship between top-down and bottom-up approaches to internal quality assurance and suggests that, with growing professionalization, more limited result-oriented audits…

  2. Total Quality Management in the Defense Fuel Supply Center: Issues and Observations.

    ERIC Educational Resources Information Center

    Matysek, Eugene F., Jr.

    1993-01-01

    Examines the Total Quality Management (TQM) activities at a federal government agency (i.e., the Defense Fuel Supply Center) using the following criteria established by the Federal Quality Institute: top management leadership and support; strategic quality planning; customer focus; training and recognition; employee empowerment and teamwork; and…

  3. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    PubMed

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  4. Macroscopic anatomy of the great vessels and structures associated with the heart of the ringed seal (Pusa hispida).

    PubMed

    Smodlaka, H; Henry, R W; Reed, R B

    2009-06-01

    The ringed seal [Pusa (Phoca) hispida], as well as other seals, exhibits unique anatomical properties when compared to its terrestrial counterparts. In the ringed seal, the most conspicuous marine adaptation is the aortic bulb. This large dilatation of the ascending aorta is comparable to that found in other seal species and marine mammals. The branches of the ascending aorta (brachiocephalic trunk, left common carotid artery and left subclavian artery) are similar to those of higher primates and man. The peculiarities of the venous system are: three pulmonary veins, a pericardial venous plexus, a caval sphincter, a hepatic sinus with paired caudal vena cavae and a large extradural venous plexus. Generally, three common pulmonary veins (right, left and caudal) empty into the left atrium. The pericardial venous plexus lies deep to the mediastinal pericardial pleura (pleura pericardica) on the auricular (ventral) surface of the heart. The caval sphincter surrounds the caudal vena cava as it passes through the diaphragm. Caudal to the diaphragm, the vena cava is dilated (the hepatic sinus), and near the cranial extremity of the kidneys, it becomes biphid. The azygos vein is formed from the union of the right and left azygos veins at the level of the 5th thoracic vertebra. Cardiovascular physiological studies show some of these anatomical variations, especially of the venous system and the ascending aorta, to be modifications for diving. This investigation documents the large blood vessels associated with the heart and related structures in the ringed seal.

  5. Management and outcome of cardiac and endovascular cystic echinococcosis.

    PubMed

    Díaz-Menéndez, Marta; Pérez-Molina, José Antonio; Norman, Francesca Florence; Pérez-Ayala, Ana; Monge-Maillo, Begoña; Fuertes, Pilar Zamarrón; López-Vélez, Rogelio

    2012-01-01

    Cystic echinococcosis (CE) can affect the heart and the vena cava but few cases are reported. A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995-2009) is reported. Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4-93 months). One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE) and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas. © 2012 Díaz-Menéndez et al.

  6. Management and Outcome of Cardiac and Endovascular Cystic Echinococcosis

    PubMed Central

    Díaz-Menéndez, Marta; Pérez-Molina, José Antonio; Norman, Francesca Florence; Pérez-Ayala, Ana; Monge-Maillo, Begoña; Fuertes, Pilar Zamarrón; López-Vélez, Rogelio

    2012-01-01

    Background Cystic echinococcosis (CE) can affect the heart and the vena cava but few cases are reported. Methods A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995–2009) is reported. Results Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4–93 months). One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE) and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. Conclusions Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas. PMID:22235354

  7. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    PubMed

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  8. The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Prochazka, Allan

    Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less

  9. [Pulsatile total cavopulmonary shunt for hypoplastic right heart syndrome with abnormal systemic venous return--a case report].

    PubMed

    Oiwa, H; Kawauchi, M; Chikada, M; Yagyu, K; Kotsuka, Y; Furuse, A

    1995-01-01

    A pulsatile total cavopulmonary shunt was successfully performed on a 5-year-old girl with hypoplastic right heart syndrome associated with abnormal systemic venous return; at the same time, modified mitral valve replacement was performed for mitral regurgitation. The right atrium, tricuspid valve and right ventricle were all extremely dimunitive. The diameter of the tricuspid valve was 50% of normal and the volume of the right ventricle was 8.6% of normal. In addition, there were severe subpumonary stenosis, a restrictive ventricular septal defect (VSD) and an atrial septal defect (ASD). The bilateral superior venae cavae (SVCs) and the hepatic vein drained to the left atrium, and the inferior vena cava was infrahepatically interrupted with a hemiazygos connection to the left superior vena cava. At the operation, each SVC was anastomosed end-to-side to each branch of the pulmonary artery (PA). The restrictive ventricular septal defect and stenotic subpulmonary lesion were left. The diameter of the ASD was reduced from 12 mm to 7 mm. The main PA was neither divided nor banded. The pulsatile blood flow from the left heart to the PA was regurated by a native restrictive VSD and stenotic subpulmonary lesion, and that from the right heart via the ASD was limited by reducing the size of the ASD. These described anatomic arrangements produced adequate antegrade pulsatile flow in the PA, which might prevent the development of pulmonary arteriovenous fistulae and, besides permit transfer of drainage of the hepatic vein from the left to the right atrium via the ASD in future.

  10. Abnormal gel flotation caused by contrast media during adrenal vein sampling.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare

    2016-10-15

    During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm 3 of density, was used close to the right adrenal vein due to some difficulty to access it. The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.

  11. Cardiopulmonary Syndrome Overview

    MedlinePlus

    ... to Cancer Off-Label Drug Use Access to Experimental Drugs Complementary & Alternative Medicine (CAM) CAM for Patients ... pressure on the heart. Treatment may be to control the symptoms of ... vena cava syndrome (SVCS) is a group of signs and symptoms that occur when the ...

  12. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

    PubMed Central

    Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W

    2013-01-01

    The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701

  13. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

    PubMed

    Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W

    2013-01-01

    The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.

  14. Differential regulation of cell functions by CSD peptide subdomains

    PubMed Central

    2013-01-01

    Background In fibrotic lung diseases, expression of caveolin-1 is decreased in fibroblasts and monocytes. The effects of this deficiency are reversed by treating cells or animals with the caveolin-1 scaffolding domain peptide (CSD, amino acids 82–101 of caveolin-1) which compensates for the lack of caveolin-1. Here we compare the function of CSD subdomains (Cav-A, Cav-B, Cav-C, Cav-AB, and Cav-BC) and mutated versions of CSD (F92A and T90A/T91A/F92A). Methods Migration toward the chemokine CXCL12 and the associated expression of F-actin, CXCR4, and pSmad 2/3 were studied in monocytes from healthy donors and SSc patients. Fibrocyte differentiation was studied using PBMC from healthy donors and SSc patients. Collagen I secretion and signaling were studied in fibroblasts derived from the lung tissue of healthy subjects and SSc patients. Results Cav-BC and CSD at concentrations as low as 0.01 μM inhibited the hypermigration of SSc monocytes and TGFβ-activated Normal monocytes and the differentiation into fibrocytes of SSc and Normal monocytes. While CSD also inhibited the migration of poorly migrating Normal monocytes, Cav-A (and other subdomains to a lesser extent) promoted the migration of Normal monocytes while inhibiting the hypermigration of TGFβ-activated Normal monocytes. The effects of versions of CSD on migration may be mediated in part via their effects on CXCR4, F-actin, and pSmad 2/3 expression. Cav-BC was as effective as CSD in inhibiting fibroblast collagen I and ASMA expression and MEK/ERK signaling. Cav-C and Cav-AB also inhibited collagen I expression, but in many cases did not affect ASMA or MEK/ERK. Cav-A increased collagen I expression in scleroderma lung fibroblasts. Full effects on fibroblasts of versions of CSD required 5 μM peptide. Conclusions Cav-BC retains most of the anti-fibrotic functions of CSD; Cav-A exhibits certain pro-fibrotic functions. Results obtained with subdomains and mutated versions of CSD further suggest that the critical functional residues in CSD depend on the cell type and readout being studied. Monocytes may be more sensitive to versions of CSD than fibroblasts and endothelial cells because the baseline level of caveolin-1 in monocytes is much lower than in these other cell types. PMID:24011378

  15. Differential regulation of cell functions by CSD peptide subdomains.

    PubMed

    Reese, Charles; Dyer, Shanice; Perry, Beth; Bonner, Michael; Oates, James; Hofbauer, Ann; Sessa, William; Bernatchez, Pascal; Visconti, Richard P; Zhang, Jing; Hatfield, Corey M; Silver, Richard M; Hoffman, Stanley; Tourkina, Elena

    2013-09-08

    In fibrotic lung diseases, expression of caveolin-1 is decreased in fibroblasts and monocytes. The effects of this deficiency are reversed by treating cells or animals with the caveolin-1 scaffolding domain peptide (CSD, amino acids 82-101 of caveolin-1) which compensates for the lack of caveolin-1. Here we compare the function of CSD subdomains (Cav-A, Cav-B, Cav-C, Cav-AB, and Cav-BC) and mutated versions of CSD (F92A and T90A/T91A/F92A). Migration toward the chemokine CXCL12 and the associated expression of F-actin, CXCR4, and pSmad 2/3 were studied in monocytes from healthy donors and SSc patients. Fibrocyte differentiation was studied using PBMC from healthy donors and SSc patients. Collagen I secretion and signaling were studied in fibroblasts derived from the lung tissue of healthy subjects and SSc patients. Cav-BC and CSD at concentrations as low as 0.01 μM inhibited the hypermigration of SSc monocytes and TGFβ-activated Normal monocytes and the differentiation into fibrocytes of SSc and Normal monocytes. While CSD also inhibited the migration of poorly migrating Normal monocytes, Cav-A (and other subdomains to a lesser extent) promoted the migration of Normal monocytes while inhibiting the hypermigration of TGFβ-activated Normal monocytes. The effects of versions of CSD on migration may be mediated in part via their effects on CXCR4, F-actin, and pSmad 2/3 expression. Cav-BC was as effective as CSD in inhibiting fibroblast collagen I and ASMA expression and MEK/ERK signaling. Cav-C and Cav-AB also inhibited collagen I expression, but in many cases did not affect ASMA or MEK/ERK. Cav-A increased collagen I expression in scleroderma lung fibroblasts. Full effects on fibroblasts of versions of CSD required 5 μM peptide. Cav-BC retains most of the anti-fibrotic functions of CSD; Cav-A exhibits certain pro-fibrotic functions. Results obtained with subdomains and mutated versions of CSD further suggest that the critical functional residues in CSD depend on the cell type and readout being studied. Monocytes may be more sensitive to versions of CSD than fibroblasts and endothelial cells because the baseline level of caveolin-1 in monocytes is much lower than in these other cell types.

  16. Quality rating and private-prices: Evidence from the nursing home industry.

    PubMed

    Huang, Sean Shenghsiu; Hirth, Richard A

    2016-12-01

    We use the rollout of the five-star rating of nursing homes to study how private-pay prices respond to quality rating. We find that star rating increases the price differential between top- and bottom-ranked facilities. On average, prices of top-ranked facilities increased by 4.8 to 6.0 percent more than the prices of bottom-ranked facilities. We find stronger price effects in markets that are less concentrated where consumers may have more choices of alternative nursing homes. Our results suggest that with simplified design and when markets are less concentrated, consumers are more responsive to quality reporting. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Team-based organization: the fruits of employee empowerment.

    PubMed

    Swick, L

    1997-11-01

    Tennalum, a division of Kaiser Aluminum, received the 1995 Shingo Prize for Excellence in Manufacturing. The plant also received the 1995 Tennessee Quality Achievement Award, the criteria for which are based on the Malcolm Baldridge National Quality Award. In 1994, Tennalum received the Clemson University's 21st Century Organizational Excellence Award, 33 Metal Producing Magazine's T.O.P. Award, and the Tennessee Quality Interest Award, and it was a finalist in Industry Week magazine's Top 10 Plants in America. Tennalum also earned ISO-9002 certification during that year. This article explains how Tennalum's people work together as self-directed work teams in an atmosphere of empowerment, involvement, and continuous improvement that translates into outstanding performance results.

  18. Taking NIRS to the field

    USDA-ARS?s Scientific Manuscript database

    Forage nutritive value (i.e., forage quality) impacts livestock health and performance, but determining the quality of forages for grazing animals is difficult. In the 1970s, development and application of bench-top near-infrared spectroscopy (NIRS) techniques to assess forage quality proved to be ...

  19. Race to the Top - Early Learning Challenge: 2015 Annual Performance Report. Maryland

    ERIC Educational Resources Information Center

    Race to the Top - Early Learning Challenge, 2016

    2016-01-01

    This Race to the Top - Early Learning Challenge (RTT-ELC) annual performance report for the year 2015 describes Maryland's accomplishments, lessons learned, challenges, and strategies Maryland will implement to address those challenges. Maryland's remarkable progress in increasing participation in their tiered quality rating and improvement…

  20. Race to the Top - Early Learning Challenge: 2015 Annual Performance Report. Vermont

    ERIC Educational Resources Information Center

    Race to the Top - Early Learning Challenge, 2016

    2016-01-01

    This Race to the Top - Early Learning Challenge (RTT-ELC) annual performance report for the year 2015 describes Vermont's accomplishments, lessons learned, challenges, and strategies Vermont will implement to address those challenges. Vermont's remarkable progress in increasing participation in their tiered quality rating and improvement system,…

  1. Race to the Top - Early Learning Challenge: 2015 Annual Performance Report. Pennsylvania

    ERIC Educational Resources Information Center

    Race to the Top - Early Learning Challenge, 2016

    2016-01-01

    This Race to the Top - Early Learning Challenge (RTT-ELC) annual performance report for the year 2015 describes Pennsylvania's accomplishments, lessons learned, challenges, and strategies Pennsylvania will implement to address those challenges. Pennsylvania's remarkable progress in increasing participation in their tiered quality rating and…

  2. Race to the Top - Early Learning Challenge: 2015 Annual Performance Report. Minnesota

    ERIC Educational Resources Information Center

    Race to the Top - Early Learning Challenge, 2016

    2016-01-01

    This Race to the Top - Early Learning Challenge (RTT-ELC) annual performance report for the year 2015 describes Minnesota's accomplishments, lessons learned, challenges, and strategies Minnesota will implement to address those challenges. Minnesota's remarkable progress in increasing participation in their tiered quality rating and improvement…

  3. 7 CFR 51.1527 - Standard pack.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... plums or prunes in the top layer of any package shall be reasonably representative in quality and size... minimum diameter, or number of fruit per package, or in accordance with the arrangement of the top layer... peach boxes, lug boxes and small consumer packages. In layer-packed California peach boxes or lug boxes...

  4. Building America Top Innovations 2014 Profile: ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2014-11-01

    This 2014 Top Innovations profile describes Building America research and support in developing and gaining adoption of ASHRAE 62.2, a residential ventilation standard that is critical to transforming the U.S. housing industry to high-performance homes.

  5. Cardiopulmonary Syndromes (PDQ®)—Patient Version

    Cancer.gov

    Cardiopulmonary syndromes are conditions of the heart and lung and can occur in some cancers. They include shortness of breath (dyspnea), chronic cough, pleural and pericardial effusion, and superior vena cava syndrome. Learn more about these conditions in this expert-reviewed summary.

  6. Dyspnea during Advanced Cancer

    MedlinePlus

    ... to Cancer Off-Label Drug Use Access to Experimental Drugs Complementary & Alternative Medicine (CAM) CAM for Patients ... pressure on the heart. Treatment may be to control the symptoms of ... vena cava syndrome (SVCS) is a group of signs and symptoms that occur when the ...

  7. College Students' Perceptions of Quality in Distance Education: The Importance of Communication

    ERIC Educational Resources Information Center

    Ortiz-Rodriguez, Madeline; Telg, Ricky W.; Irani, Tracy; Roberts, T. Grady; Rhoades, Emily

    2005-01-01

    Quality in distance education has been studied mostly from a top-down approach, from administration and faculty to students. This study was an attempt to understand quality through the eyes of the distance learner. This study identified undergraduate and graduate students' perceptions about quality in distance education, examining factors…

  8. Genotype, environment, seeding rate, and top-dressed nitrogen effects on end-use quality of modern Nebraska winter wheat.

    PubMed

    Bhatta, Madhav; Regassa, Teshome; Rose, Devin J; Baenziger, P Stephen; Eskridge, Kent M; Santra, Dipak K; Poudel, Rachana

    2017-12-01

    Fine-tuning production inputs such as seeding rate, nitrogen (N), and genotype may improve end-use quality of hard red winter wheat (Triticum aestivium L.) when growing conditions are unpredictable. Studies were conducted at the Agronomy Research Farm (ARF; Lincoln, NE, USA) and the High Plains Agricultural Laboratory (HPAL; Sidney, NE, USA) in 2014 and 2015 in Nebraska, USA, to determine the effects of genotype (6), environment (4), seeding rate (3), and flag leaf top-dressed N (0 and 34 kg N ha -1 ) on the end-use quality of winter wheat. End-use quality traits were influenced by environment, genotype, seeding rate, top-dressed N, and their interactions. Mixograph parameters had a strong correlation with grain volume weight and flour yield. Doubling the recommended seeding rate and N at the flag leaf stage increased grain protein content by 8.1% in 2014 and 1.5% in 2015 at ARF and 4.2% in 2014 and 8.4% in 2015 at HPAL. The key finding of this research is that increasing seeding rates up to double the current recommendations with N at the flag leaf stage improved most of the end-use quality traits. This will have a significant effect on the premium for protein a farmer could receive when marketing wheat. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. A Survey of Current Valued Academic Leadership Qualities in Nursing.

    PubMed

    Delgado, Cheryl; Mitchell, Maureen M

    2016-01-01

    An informal survey was used to identify nurse faculty leadership qualities currently valued and relevant. The accelerating retirement rate for seasoned leaders has created a need for nurse educators and academic leaders. Our school was concerned that we were not meeting students' needs for today's leadership challenges. We were also interested in the experiences of leadership preparation. This was a cross-sectional, online survey of faculty at top nursing schools as determined by US News & World Report. The top leadership qualities identified were integrity, communication clarity, and problem-solving ability. Current challenges for leaders were finding qualified faculty, obtaining resources, and team building. The results may guide curricular adjustments and the transition to a new generation of nurse academic leaders.

  10. Patients with inferior vena cava thrombosis frequently present with lower back pain and bilateral lower-extremity deep vein thrombosis.

    PubMed

    Kraft, Christiane; Hecking, Carola; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit

    2013-07-01

    Inferior vena cava (IVC) thrombosis is rare, and data about the clinical presentation of patients are scarce. Therefore, we reviewed all cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described patients’ characteristics in terms of their clinical presentations in the acute setting of IVC thrombosis. From the MAISTHRO registry, which enrolled 1470 consecutive patients with documented histories of venous thromboembolism, we identified 60 patients (0,4 %; females 60 %) with IVC thrombosis and 888 patients (60.4 %; females 55 %) with isolated lower-extremity deep vein thrombosis (LE-DVT). The median age at the time of IVC thrombosis manifestation was 36.5 years (9 to 83). IVC thrombosis was the initial VTE event in 47 patients (78 %). In the majority of cases, IVC thrombosis extended to the lower-extremity veins, and both lower extremities were affected in 17 cases (28 %). The initial clinical symptom of IVC thrombosis was lower back or abdominal pain which preceded typical symptoms of LE-DVT in 29 (48 %) patients. Symptomatic pulmonary embolism was more frequently observed in IVC thrombosis patients when compared to a sex- and age-matched subgroup of LE-DVT patients, although the difference was not significant (27 % vs. 12 %; p = 0.064). Malignant disease was the only established VTE risk factor with a higher prevalence among IVC thrombosis patients than patients with isolated LE-DVT (27 % vs. 9 %; p = 0.015). Congenital IVC anomalies were identified in another eight IVC thrombosis patients (13 %). IVC thrombosis should be considered a differential diagnosis for inexplicable lower back or abdominal pain especially in young patients. Malignant disease and congenital IVC anomalies seem to be predisposing factors for thrombosis involving the inferior vena cava.

  11. Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience.

    PubMed

    Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R

    2015-10-01

    Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.

  12. [Superior vena cava syndrome unrelated to central venous catheter in a patient on chronic hemodialysis].

    PubMed

    Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio

    2011-01-01

    A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.

  13. Real-time monitoring of spinal cord blood flow with a novel sensor mounted on a cerebrospinal fluid drainage catheter in an animal model.

    PubMed

    Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsunaga, Tadao; Haga, Yoichi; Saiki, Yoshikatsu

    2014-10-01

    The aim of our study was to develop a novel monitoring system for spinal cord blood flow (SCBF) to test the efficacy of the SCBF sensor in an animal model. The sensor system consisted of 2 optical fibers, a pedestal for fiber fixation, and a mirror for the laser reflection and was incorporated into a cerebrospinal fluid drainage catheter. In vivo studies were performed in a swine model (n=10) to measure SCBF during spinal cord ischemia induced by clamping the descending thoracic aorta and supra-aortic neck vessels, when necessary. A temporary low cardiac output model was also created by inflow clamping of the inferior vena cava to analyze the quantitative changes in SCBF during this maneuver. The developed SCBF monitoring catheter placed intrathecally could detect SCBF in all the swine. The SCBF after aortic crossclamping at the fourth intercostal level exhibited diverse changes reproducibly among the swine, with a >25% reduction in SCBF in 5 pigs, an increase in 3, and no significant changes in 2. Consistent reductions were recorded during inferior vena cava occlusion. The mean SCBF decreased by 32% after inferior vena cava occlusion when the cardiac output had decreased by 27%. We have developed a novel SCBF sensor that could detect real-time changes in spinal cord perfusion in a swine model. The device holds promise to detect imminent ischemia or ensure acceptable blood perfusion in the spinal cord and could further enhance our understanding of spinal cord circulation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  14. Increasing cyanosis early after cavopulmonary connection caused by abnormal systemic venous channels.

    PubMed

    Gatzoulis, M A; Shinebourne, E A; Redington, A N; Rigby, M L; Ho, S Y; Shore, D F

    1995-02-01

    To show that abnormal systemic venous channels in patients who undergo cavopulmonary anastomoses can become manifest and haemodynamically important only after surgery despite detailed preoperative investigation. Descriptive study of patients fulfilling the above criteria selected from hospital records over the past three years. A tertiary referral centre. Of the three cases identified, two were isomeric, one with left atrial isomerism and hemiazygos continuation of the inferior vena cava who underwent bilateral bidirectional Glenn anastomoses and one with right isomerism who underwent total cavopulmonary anastomosis. Case 3 had absent left atrioventricular connection with a hypoplastic left lung and underwent a classic right Glenn procedure. All three cases presented with progressive cyanosis in the early postoperative period. Postoperative angiography in case 1 showed a remnant of a left inferior vena cava draining to the atrium to have become grossly dilated causing cyanosis, which resolved after redirection of this vessel and of the hepatic veins into the right pulmonary artery with an intra-atrial baffle. Cyanosis in case 2 was caused by intra-hepatic shunting to a hepatic vein draining to the left of the intra-atrial baffle. The diagnosis was made at necropsy, being overlooked on postoperative angiography. Repeat angiography in case 3 showed progressive dilatation of a small left superior vena cava to coronary sinus. Test occlusion with a view to embolisation revealed hitherto an undemonstrated hemiazygos continuation of inferior caval to brachiocephalic vein. The patient underwent surgical ligation of these two venous channels. Despite appropriate investigation some "abnormal" venous pathways manifest themselves, dilate, and become haemodynamically important only after surgical cavopulmonary anastomoses. In the presence of early postoperative cyanosis "new" systemic venous collateral channels should be considered as a possible cause, which may require reintervention.

  15. Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika

    The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%)more » had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).« less

  16. Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana

    Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less

  17. Angiotensin-II receptor 1 antagonist fetopathy--risk assessment, critical time period and vena cava thrombosis as a possible new feature.

    PubMed

    Oppermann, Marc; Padberg, Stephanie; Kayser, Angela; Weber-Schoendorfer, Corinna; Schaefer, Christof

    2013-03-01

    Angiotensin-II receptor 1 antagonists (AT₁-antagonists) may cause severe and even lethal fetopathy in late pregnancy. However, exposure still occurs in spite of warnings in package leaflets. This study aimed to assess the risk of fetopathy, the sensitive time window, and possible new symptoms in prospective as well as retrospective cases with AT₁-antagonist treatment during the second or third trimester of pregnancy. Patients were enrolled by the Berlin Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy between 1999 and 2011 through risk consultation. Symptoms defined as indicative of AT₁-antagonist fetopathy were: oligo-/anhydramnios, renal insufficiency, lung hypoplasia, joint contractures, skull hypoplasia and fetal/neonatal death. In 5/29 (17%) prospectively enrolled cases with AT₁-antagonist exposure beyond the first trimester oligo-/anhydramnios was diagnosed. Two infants showed additional symptoms of fetopathy. The risk is more than 30% if treatment continues beyond the 20th week of pregnancy. Oligo-/anhydramnios was reversible after AT₁-antagonist withdrawal. Among 16 retrospective case reports, three infants presented with a thrombosis of the inferior vena cava in the vicinity of the renal veins. Four out of 13 live births did not survive. Our survey suggests that the risk increases with duration of AT₁-antagonist treatment into late pregnancy and oligo-/anhydramnios may be reversible after AT₁-antagonist discontinuation. Thrombosis of inferior vena cava may be a new feature of AT₁-antagonist fetopathy. AT₁-antagonist medication during pregnancy constitutes a considerable risk and must be discontinued immediately. In case of indicative diagnostic findings in either the fetus or newborn, previous maternal AT₁-antagonist exposure should be considered. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  18. The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

    PubMed

    Peachey, Tom; Tang, Andrew; Baker, Elinor C; Pott, Jason; Freund, Yonathan; Harris, Tim

    2016-09-02

    Assessment of circulating volume and the requirement for fluid replacement are fundamental to resuscitation but remain largely empirical. Passive leg raise (PLR) may determine fluid responders while avoiding potential fluid overload. We hypothesised that inferior vena cava collapse index (IVCCI) and carotid artery blood flow would change predictably in response to PLR, potentially providing a non-invasive tool to assess circulating volume and identifying fluid responsive patients. We conducted a prospective proof of concept pilot study on fasted healthy volunteers. One operator measured IVC diameter during quiet respiration and sniff, and carotid artery flow. Stroke volume (SV) was also measured using suprasternal Doppler. Our primary endpoint was change in IVCCI after PLR. We also studied changes in IVCCI after "sniff", and correlation between carotid artery flow and SV. Passive leg raise was associated with significant reduction in the mean inferior vena cava collapsibility index from 0.24 to 0.17 (p < 0.01). Mean stroke volume increased from 56.0 to 69.2 mL (p < 0.01). There was no significant change in common carotid artery blood flow. Changes in physiology consequent upon passive leg raise normalised rapidly. Passive leg raise is associated with a decrease of IVCCI and increase in stroke volume. However, the wide range of values observed suggests that factors other than circulating volume predominate in determining the proportion of collapse with respiration. In contrast to other studies, we did not find that carotid blood flow increased with passive leg raise. Rapid normalisation of post-PLR physiology may account for this.

  19. [Extracorporeal circulation and hypothermy surgery in tumors with vena cava extension: 20 years experience at the University Clinic of Navarra].

    PubMed

    Rioja Zuazu, J; Rodríguez-Rubio Cortadillas, F; Zudaire Bergera, J J; Saiz Sansi, A; Rosell Costa, D; Robles García, J E; Rábago, G; Berián Polo, J M

    2008-04-01

    We present our 20 years experience treating patients with vena cava extension in whom an extracorporeal circulation, hypothermia, cardio circulatory arrest (ECC-H-CCA) in order to perform, together with a tumoral resection, a thrombus resection. From 1985 to 2005 a total of 28 retroperitoneal tumor were treated: 25 renal cancers, a Wilms tumor, a paratesticular rabdomiosarcoma, and a pheocromocitoma. All of them had an extension by means of thrombus above the suprahepatics veins. All of them were treated by means of ECC-H-CCA for thrombus extraction. A descriptive study of the serie is performed as well as a Kaplan Meyer survival study. Surgical complications were present within 10 patients (35%), with a surgical mortality of two patients (7%): one intra-operatively because a massive embolism of the lungs and the other because of a lung embolism on the 4th post-operative day. Global actuarial survival was 29.1+/-10% at three years and 17.5+/-8% at five years. Analyzing only who do not have metastatic lesions, nor lymph nodes at diagnosis their three year survival was 50.9+/-16.3% and 32.2+/-16% at five years. Mean while those who have any metastatic lesion at diagnosis their three and five years survival was 20.8+/-12% and 10.4+/-9% respectively. The employ of surgical techniques with ECC-H-CCA with in oncological pathology associated with vena cava thrombus is justified and its employment does not worsen the survival; it is indicated because its results, allowing a complete tumoral resection in a safe and reproducible fashion.

  20. Headspace solid-phase microextraction coupled to gas chromatography-tandem mass spectrometry for the determination of haloanisoles in sparkling (cava and cider) and non-sparkling (wine) alcoholic beverages.

    PubMed

    Ruiz-Delgado, Ana; Arrebola-Liébanas, Francisco Javier; Romero-González, Roberto; López-Ruiz, Rosalía; Garrido Frenich, Antonia

    2016-10-01

    A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO 2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R 2  > 0.98) within the tested range (1-50 ng l -1 ). Recoveries were evaluated at three different levels (1, 5 and 50 ng l -1 ) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l -1 , which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l -1 .

  1. Effects of Ecklonia cava polyphenol in individuals with hypercholesterolemia: a pilot study.

    PubMed

    Lee, Dong Hyeon; Park, Mi Yeon; Shim, Byung Joo; Youn, Ho Joong; Hwang, Hye Jeong; Shin, Hyeon Cheol; Jeon, Hui Kyung

    2012-11-01

    We evaluated the efficacy and safety of Ecklonia cava polyphenol (Seapolynol™, a polyphenol antioxidant and anti-inflammatory agent purified from E. cava) during a 12-week treatment period (400 mg orally once daily) in individuals with hypercholesterolemia and performed subgroup analysis for metabolic syndrome (MetS). As a noncomparative study, forty-six individuals (M:F=22:24, mean age=54±11 years) with fasting total cholesterol concentration >240 mg/dL or low-density lipoprotein cholesterol (LDL-C) concentration >130 mg/dL were enrolled. Hip circumference (100±7 cm vs. 98±7 cm, P<.01), total cholesterol (244±25 mg/dL vs. 225±37 mg/dL, P<.01), LDL-C (161±24 mg/dL vs. 146±34 mg/dL, P<.01), and C-reactive protein (2.51±3.55 mg/L vs. 1.37±1.32 mg/L, P<.05) were significantly decreased without significant adverse effect. A differential assessment according to the presence [MetS(+) group, n=18] and absence [MetS(-) group, n=28] of MetS showed that Hb(A1c) decreased significantly following 12-week Seapolynol treatment in the MetS(+) compared with the MetS(-) group (-0.3%±0.5% vs. 0.1%±0.3%, P<.01). In conclusion, although our results showed that Seapolynol treatment is effective and safe without significant adverse events or abnormal laboratory findings during a 12-week period in individuals with hypercholesterolemia, more research in a larger population with a longer-term follow-up period in a randomized placebo-controlled study is needed to confirm the results.

  2. Abnormal gel flotation caused by contrast media during adrenal vein sampling

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare

    2016-01-01

    Introduction During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. Materials and methods A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to
confirm the catheter’s position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. Results At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. Conclusion The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated
contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays. PMID:27812311

  3. Bleeding 'downhill' esophageal varices associated with benign superior vena cava obstruction: case report and literature review.

    PubMed

    Loudin, Michael; Anderson, Sharon; Schlansky, Barry

    2016-10-24

    Proximal or 'downhill' esophageal varices are a rare cause of upper gastrointestinal hemorrhage. Unlike the much more common distal esophageal varices, which are most commonly a result of portal hypertension, downhill esophageal varices result from vascular obstruction of the superior vena cava (SVC). While SVC obstruction is most commonly secondary to malignant causes, our review of the literature suggests that benign causes of SVC obstruction are the most common cause actual bleeding from downhill varices. Given the alternative pathophysiology of downhill varices, they require a unique approach to management. Variceal band ligation may be used to temporize acute variceal bleeding, and should be applied on the proximal end of the varix. Relief of the underlying SVC obstruction is the cornerstone of definitive treatment of downhill varices. A young woman with a benign superior vena cava stenosis due to a tunneled internal jugular vein dialysis catheter presented with hematemesis and melena. Urgent upper endoscopy revealed multiple 'downhill' esophageal varices with stigmata of recent hemorrhage. As there was no active bleeding, no endoscopic intervention was performed. CT angiography demonstrated stenosis of the SVC surrounding the distal tip of her indwelling hemodialysis catheter. The patient underwent balloon angioplasty of the stenotic SVC segment with resolution of her bleeding and clinical stabilization. Downhill esophageal varices are a distinct entity from the more common distal esophageal varices. Endoscopic therapies have a role in temporizing active variceal bleeding, but relief of the underlying SVC obstruction is the cornerstone of treatment and should be pursued as rapidly as possible. It is unknown why benign, as opposed to malignant, causes of SVC obstruction result in bleeding from downhill varices at such a high rate, despite being a less common etiology of SVC obstruction.

  4. Retrievable Inferior Vena Cava Filters: Indications, Indwelling Time, Removal, Success and Complication Rates.

    PubMed

    Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli

    2016-02-01

    Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

  5. Puerperal ovarian vein thrombosis: two case reports.

    PubMed

    Angelini, Marta; Barillari, Giovanni; Londero, Ambrogio P; Bertozzi, Serena; Bernardi, Sergio; Petri, Roberto; Driul, Lorenza; Marchesoni, Diego

    2013-02-01

    Ovarian vein thrombosis (OVT) is an uncommon but potentially serious complication in the early postpartum. Two case studies seem to prove the point: Case 1 A 24-year-old woman was transferred to our hospital with the chief complaint of abdominal pain radiating to the right thigh, vomit, diarrhea, and a slight pyrexia (37.6 °C rectal). Five days earlier, she had a spontaneous vaginal delivery after labor induction. The woman appeared slightly distressed because of pain; vital signs were found to be normal and the CRP elevated (129.9 mg/L). Abdominal examination was remarkable for tenderness by palpation in the right lower quadrant with no rebound tenderness or guarding. Pelvic examination was remarkable for mild right adnexal tenderness. Abdominal-pelvic computer tomography with contrast medium revealed a 2.5-cm OVT having extended into the inferior vena cava for 14 cm with a slight peripheral edema. The patient was treated with nadroparin 0.6 cc (5700 IU) bid and warfarin 5 mg since the attainment of the therapeutic INR range. Case 2 A 31-year-old twin-pregnant woman had an emergency cesarean section at 35 gestational weeks because of hypertension complicated by increased liver enzymes, diuresis contraction, and continuous lower back pain bilaterally radiating to the groins. One day after delivery, CT scan that was performed because of onward anemia showed a pelvic, perihepatic, and perisplenic blood effusion, and a 1-cm right OVT extended to the inferior vena cava below renal veins for 28 mm. She underwent exploratory laparotomy and blood transfusion, and because of respiratory insufficiency she was transferred to a second level center with ICU facility, where she was placed under a suprarenal inferior vena cava filter, and AngioJet Rheolytic Thrombectomy for acute pulmonary embolism was performed.

  6. Rankings Methodology Hurts Public Institutions

    ERIC Educational Resources Information Center

    Van Der Werf, Martin

    2007-01-01

    In the 1980s, when the "U.S. News & World Report" rankings of colleges were based solely on reputation, the nation's public universities were well represented at the top. However, as soon as the magazine began including its "measures of excellence," statistics intended to define quality, public universities nearly disappeared from the top. As the…

  7. Pulp quality from small-diameter trees.

    Treesearch

    G.C. Myers; S. Kumar; R.R. Gustafson; R.J. Barbour; S.M. Abubakr

    1997-01-01

    Kraft and thermomechanical (TMP) pulps were prepared and evaluated from lodgepole pine and mixed Douglas-fir/western larch sawmill residue chips; lodgepole pine, Douglas-fir, and western larch submerchantable logs; and lodgepole pine, Douglas-fir, and western larch small trees and tops. Kraft pulp from small trees and tops was identical to that from submerchantable...

  8. Race to the Top - Early Learning Challenge: 2015 Annual Performance Report. New Jersey

    ERIC Educational Resources Information Center

    Race to the Top - Early Learning Challenge, 2016

    2016-01-01

    This Race to the Top - Early Learning Challenge (RTT-ELC) annual performance report for the year 2015 describes New Jersey's accomplishments, lessons learned, challenges, and strategies New Jersey will implement to address those challenges. New Jersey's remarkable progress in increasing participation in their tiered quality rating and improvement…

  9. Round Top Butte Research Natural Area: guidebook supplement 46

    Treesearch

    Marcia L. Wineteer; Reid Schuller

    2014-01-01

    This guidebook describes major biological and physical attributes of the 243-ha (600-ac) Round Top Butte Research Natural Area. The area supports high-quality examples of valley upland grasslands and savanna of the Cascade foothills. Plant communities include Oregon white oak (Quercus garryana) savanna and open woodland with forbs and grasses;...

  10. NREL Researcher is Top World Physicist

    Science.gov Websites

    is Top World Physicist For more information contact: Kerry Masson, (303) 275-4083 e:mail physicists in the world by the Institute of Scientific Information (ISI). The standing is based on the number your peers is the ultimate measure of the quality and quantity of world class research being conducted

  11. Nanoscale imaging with table-top coherent extreme ultraviolet source based on high harmonic generation

    NASA Astrophysics Data System (ADS)

    Ba Dinh, Khuong; Le, Hoang Vu; Hannaford, Peter; Van Dao, Lap

    2017-08-01

    A table-top coherent diffractive imaging experiment on a sample with biological-like characteristics using a focused narrow-bandwidth high harmonic source around 30 nm is performed. An approach involving a beam stop and a new reconstruction algorithm to enhance the quality of reconstructed the image is described.

  12. On the Home Front: Early Care and Education a Top Priority for Military Families

    ERIC Educational Resources Information Center

    Coleman, Alice

    2011-01-01

    Military parents with young children report that the need for early care and education services, including high-quality pre-kindergarten, tops their list of day-to-day needs. Frequent relocations and the cycle of deployment--preparation, separation and reunification--all cause disruptions that can have profound emotional and educational…

  13. Auditing the Assignments of Top-Level Semantic Types in the UMLS Semantic Network to UMLS Concepts

    PubMed Central

    He, Zhe; Perl, Yehoshua; Elhanan, Gai; Chen, Yan; Geller, James; Bian, Jiang

    2018-01-01

    The Unified Medical Language System (UMLS) is an important terminological system. By the policy of its curators, each concept of the UMLS should be assigned the most specific Semantic Types (STs) in the UMLS Semantic Network (SN). Hence, the Semantic Types of most UMLS concepts are assigned at or near the bottom (leaves) of the UMLS Semantic Network. While most ST assignments are correct, some errors do occur. Therefore, Quality Assurance efforts of UMLS curators for ST assignments should concentrate on automatically detected sets of UMLS concepts with higher error rates than random sets. In this paper, we investigate the assignments of top-level semantic types in the UMLS semantic network to concepts, identify potential erroneous assignments, define four categories of errors, and thus provide assistance to curators of the UMLS to avoid these assignments errors. Human experts analyzed samples of concepts assigned 10 of the top-level semantic types and categorized the erroneous ST assignments into these four logical categories. Two thirds of the concepts assigned these 10 top-level semantic types are erroneous. Our results demonstrate that reviewing top-level semantic type assignments to concepts provides an effective way for UMLS quality assurance, comparing to reviewing a random selection of semantic type assignments. PMID:29375930

  14. Auditing the Assignments of Top-Level Semantic Types in the UMLS Semantic Network to UMLS Concepts.

    PubMed

    He, Zhe; Perl, Yehoshua; Elhanan, Gai; Chen, Yan; Geller, James; Bian, Jiang

    2017-11-01

    The Unified Medical Language System (UMLS) is an important terminological system. By the policy of its curators, each concept of the UMLS should be assigned the most specific Semantic Types (STs) in the UMLS Semantic Network (SN). Hence, the Semantic Types of most UMLS concepts are assigned at or near the bottom (leaves) of the UMLS Semantic Network. While most ST assignments are correct, some errors do occur. Therefore, Quality Assurance efforts of UMLS curators for ST assignments should concentrate on automatically detected sets of UMLS concepts with higher error rates than random sets. In this paper, we investigate the assignments of top-level semantic types in the UMLS semantic network to concepts, identify potential erroneous assignments, define four categories of errors, and thus provide assistance to curators of the UMLS to avoid these assignments errors. Human experts analyzed samples of concepts assigned 10 of the top-level semantic types and categorized the erroneous ST assignments into these four logical categories. Two thirds of the concepts assigned these 10 top-level semantic types are erroneous. Our results demonstrate that reviewing top-level semantic type assignments to concepts provides an effective way for UMLS quality assurance, comparing to reviewing a random selection of semantic type assignments.

  15. Medicaid plan, health centers reveal secrets to boosting HEDIS scores, quality of care.

    PubMed

    1999-07-01

    How to do well on HEDIS measurement and boost quality of care for your Medicaid members. Neighborhood Health Plan in Boston, MA, attributes its top performance on Medicaid HEDIS measures to providers' care models, a commitment to quality, and the quest for performance data.

  16. Ground-water hydrology and quality before and after strip mining of a small watershed in Jefferson County, Ohio

    USGS Publications Warehouse

    Razem, A.C.

    1984-01-01

    Ground-water conditions before and after surface mining of a small watershed are described as part of a study to determine the effects of mining on hydrologic systems. The watershed was underlain by stratified sedimentary rocks containing local aquifers above shaley clay beds associated with the major coal seams. Mining involved removing the overburden rocks, including most of the top aquifer, stripping the coal, and recontouring the overburden spoils to the approximate premining shape of the watershed. Replacement of the top aquifer by spoils during regrading has caused many changes in recharge and discharge rates, saturated thickness, aquifer characteristics, and water quality. In the middle aquifer there were changes in saturated thickness and water quality. Resaturation of the top-aquifer spoils during and after reclamation has been slow. Saturated thicknesses have ranged from zero initially after mining to 4 feet after 1 1/2 years. Water levels in the middle aquifer have risen from a few feet to 40 feet. Water quality generally has been degraded: concentrations of bicarbonate, calcium, magnesium , chloride, iron, manganese, sulfate, and dissolved solids have increased. Premining water types remained about the same after mining, except for some changes from bicarbonate type to sulfate type. (USGS)

  17. Investigations of structural defects, crystalline perfection, metallic impurity concentration and optical quality of flat-top KDP crystal

    NASA Astrophysics Data System (ADS)

    Sharma, S. K.; Verma, Sunil; Singh, Yeshpal; Bartwal, K. S.; Tiwari, M. K.; Lodha, G. S.; Bhagavannarayana, G.

    2015-08-01

    KDP crystal grown using flat-top technique has been characterized using X-ray and optical techniques with the aim of correlating the defects structure and impurity concentration in the crystal with its optical properties. Crystallographic defects were investigated using X-ray topography revealing linear and arc like chains of dislocations and to conclude that defects do not originate from the flat-top part of the crystal. Etching was performed to quantify dislocation defects density. The crystalline perfection of the crystal was found to be high as the FWHM of the rocking curves measured at several locations was consistently low 6-9 arc s. The concentration of Fe metallic impurity quantified using X-ray fluorescence technique was approximately 5 times lower in the flat-top part which falls in pyramidal growth sector as compared to the region near to the seed which lies in prismatic sector. The spectrophotometric characterization for plates cut normal to different crystallographic directions in the flat-top potassium dihydrogen phosphate (FT-KDP) crystal was performed to understand the influence of metallic impurity distribution and growth sectors on the optical transmittance. The transmittance of the FT-KDP crystal at 1064 nm and its higher harmonics (2nd, 3rd, 4th and 5th) was determined from the measured spectra and the lower transmission in the UV region was attributed to increased absorption by Fe metallic impurity at these wavelengths. The results are in agreement with the results obtained using X-ray fluorescence and X-ray topography. Birefringence and Mach-Zehnder interferometry show that except for the region near to the seed crystal the optical homogeneity of the entire crystal was good. The laser-induced damage threshold (LDT) values are in the range 2.4-3.9 GW/cm2. The LDT of the plate taken from the flat-top region is higher than that from the bottom of the crystal, indicating that the flat-top technique has good optical quality and is comparable to those reported using rapid growth technique. The results indicate that the structural defects, crystalline quality and impurity concentration have a correlation with the optical properties of the FT-KDP crystal.

  18. SvO2 Trigger in Transfusion Strategy After Cardiac Surgery

    ClinicalTrials.gov

    2018-03-27

    Undergoing Nonemergent Cardiac Surgery; Central Venous Catheter on the Superior Vena Cava (to Perform ScVO2 Measure); Anemia (<9g/dL) Requiring Blood Transfusion; Hemodynamic and Respiratory Stability; Bleeding Graded as Insignificant, Mild, Moderate of Universal Definition of Perioperative Bleeding

  19. [Leiomyosarcoma of the inferior vena cava: a case report and review].

    PubMed

    Yo, Toeki; Taoka, Rikiya; Hanasaki, Takeshi; Nakanishi, Yukako; Togo, Yoshikazu; Suzuki, Toru; Higuchi, Yoshihide; Zozumi, Masataka; Hirota, Seiichi; Kanematsu, Akihiro; Nojima, Michio; Yamamoto, Shingo

    2014-03-01

    A 37-year-old woman with an incidentally found abdominal mass was referred to our hospital. A fixed, non-tender mass was palpated in the right upper quadrum of her abdomen. There was no elevation of tumor markers. Computed tomography revealed a mass extending from the hepatic vein level to renal hilar level. The tumor completely obstructed the inferior vena cava (IVC). T1-weighted magnetic resonance imaging (MRI) showed that the mass was isointense with muscles. T2-weighted MRI image with contrast medium demonstrated collateral circulation. Upon diagnosis of the IVC tumor, we removed the right kidney and the tumor en bloc without reconstructing IVC. The tumor diameter was 11.6 × 5.5 × 4.7 cm. Pathological examination established a diagnosis of IVC leiomyosarcoma. She is alive without sign of recurrence after operation for seven months. There were 143 reports of IVC leiomyosarcoma in Japan. In 31% of them, IVC was not reconstructed.

  20. Three-Dimensional Reconstruction of Thoracic Structures: Based on Chinese Visible Human

    PubMed Central

    Luo, Na; Tan, Liwen; Fang, Binji; Li, Ying; Xie, Bing; Liu, Kaijun; Chu, Chun; Li, Min

    2013-01-01

    We managed to establish three-dimensional digitized visible model of human thoracic structures and to provide morphological data for imaging diagnosis and thoracic and cardiovascular surgery. With Photoshop software, the contour line of lungs and mediastinal structures including heart, aorta and its ramus, azygos vein, superior vena cava, inferior vena cava, thymus, esophagus, diaphragm, phrenic nerve, vagus nerve, sympathetic trunk, thoracic vertebrae, sternum, thoracic duct, and so forth were segmented from the Chinese Visible Human (CVH)-1 data set. The contour data set of segmented thoracic structures was imported to Amira software and 3D thorax models were reconstructed via surface rendering and volume rendering. With Amira software, surface rendering reconstructed model of thoracic organs and its volume rendering reconstructed model were 3D reconstructed and can be displayed together clearly and accurately. It provides a learning tool of interpreting human thoracic anatomy and virtual thoracic and cardiovascular surgery for medical students and junior surgeons. PMID:24369489

  1. Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data

    PubMed Central

    Molvar, Christopher

    2012-01-01

    Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414

  2. Downhill oesophageal variceal bleeding: A rare complication in Behçet's disease-related superior vena cava syndrome.

    PubMed

    Ennaifer, Rym; B'chir Hamzaoui, Saloua; Larbi, Thara; Romdhane, Hayfa; Abdallah, Maya; Bel Hadj, Najet; M'rad, Sander

    2015-03-01

    Behçet's disease (BD) is a multisystemic disorder that involves vessels of all sizes. Superior vena cava (SVC) thrombosis is a rare complication that can lead to the development of various collateral pathways. A 31-year-old man presented with SVC syndrome. He had a history of recurrent genital aphthosis. Computed tomography revealed extensive thrombosis of the right internal jugular, axillary, and subclavian veins with collateral circulation. The patient was diagnosed with BD, and he was started on anticoagulation and immunosuppressive therapy. One week later, he presented with haematemesis. Upper gastrointestinal endoscopy disclosed varices in the upper third of the oesophagus with stigmata of recent bleeding. Portal hypertension was ruled out. Anticoagulation therapy was discontinued. He was discharged on immunosuppressive therapy. Bleeding from downhill oesophageal varices should be suspected in any patient presenting with upper gastrointestinal bleeding and a history of SVC syndrome due to BD. Copyright © 2015 Arab Journal of Gastroenterology. Published by Elsevier B.V. All rights reserved.

  3. Complications of inferior vena cava filters

    PubMed Central

    Grewal, Simer; Chamarthy, Murthy R.

    2016-01-01

    Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983

  4. Morphology of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats.

    PubMed

    White, R N; Parry, A T

    2013-09-01

    To describe the anatomy of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Forty-six dogs and 27 cats met the inclusion criteria of a congenital portosystemic shunt emanating from the left gastric vein. Of the 46 dogs, 28 (61%) had a shunt that entered the left phrenic vein, 10 (22%) had a shunt that entered the post hepatic caudal vena cava and in 8 (17%) the shunt entered the azygos vein. Of the 27 cats, 19 (70%) had a shunt that entered the left phrenic vein and 8 (30%) had a shunt that entered the post hepatic caudal vena cava. The systemic vein into which the shunt entered was consistent showing three common presentations: left gastro-phrenic, left gastro-caval and left gastro-azygos. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2013 British Small Animal Veterinary Association.

  5. A rare congenital extrahepatic portosystemic shunt affecting the inferior mesenteric vein, inferior vena cava, and left ovarian vein.

    PubMed

    Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi

    2014-09-01

    To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.

  6. Successful laparoscopic division of a patent ductus venosus: report of a case.

    PubMed

    Hara, Yoshiaki; Sato, Yoshinobu; Yamamoto, Satoshi; Oya, Hiroshi; Igarashi, Masato; Abe, Satoshi; Kokai, Hidenaka; Miura, Kohei; Suda, Takeshi; Nomoto, Minoru; Aoyagi, Yutaka; Hatakeyama, Katsuyoshi

    2013-04-01

    Patent ductus venosus (PDV) is a rare condition of a congenital portosystemic shunt from the umbilical vein to the inferior vena cava. This report presents the case of an adult patient with PDV, who was successfully treated with laparoscopic shunt division. A 69-year-old male was referred with hepatic encephalopathy. Contrast-enhanced CT revealed a large connection between the left portal vein and the inferior vena cava, which was diagnosed as PDV. The safety of a shunt disconnection was confirmed using a temporary balloon occlusion test for the shunt, and the shunt division was performed laparoscopically. The shunt was carefully separated from the liver parenchyma with relative ease, and then divided using a vascular stapler. Portal flow was markedly increased after the operation, and the liver function of the patient improved over the 3-month period after surgery. Although careful interventional evaluation for portal flow is absolutely imperative prior to surgery, a minimally invasive laparoscopic approach can be safely used for treating PDV.

  7. PROTEIN METABOLISM AND EXCHANGE AS INFLUENCED BY CONSTRICTION OF THE VENA CAVA

    PubMed Central

    McKee, Frank W.; Schloerb, Paul R.; Schilling, John A.; Tishkoff, Garson H.; Whipple, George H.

    1948-01-01

    Constriction of inferior vena cava above the diaphragm is used to produce experimental ascites in the dog. This type of experimental ascites drains the body protein reserves, reduces the level of circulating plasma proteins, and in effect is an internal plasmapheresis. As the ascitic fluid is withdrawn and the proteins measured, we observe a production of ascitic protein (80–90 gm. per week) comparable to that removed by plasmapheresis (bleeding and replacement of red cells in saline). High protein diet tends to decrease the ascites but the protein content of the ascitic fluid may increase. Sodium chloride increases notably the volume of the ascites which accumulates and the total ascitic protein output increases. Sodium-free salt mixtures have a negative influence. High protein diet low in sodium salts gives minimal ascitic accumulation under these conditions. The question of circulation of the ascitic fluid is raised—how rapid is the absorption and the related accumulation? PMID:18858638

  8. Mesenteric-portal axis thrombosis and deep venous thrombosis in a patient with inferior vena cava agenesis.

    PubMed

    Lluis Pons, Laia; Chahri Vizcarro, Nadia; Llaverias Borrell, Silvia; Miquel Abbad, Carlos

    2017-06-01

    Splenoportal axis thrombosis not associated with cirrhosis or neoplasms has a prevalence lower than 5 per 10,000 people. An etiologic factor responsible for portal thrombosis is finally identified in most cases, usually systemic thrombogenic factors or predisposing local factors. However, despite a detailed study of all etiologic factors, up to 30% of cases are eventually considered as idiopathic in origin. We report the case of a 41-year-old patient who presented with abdominal pain and lower extremity edema. The patient was diagnosed with portal and mesenteric-portal confluence thrombosis, bilateral deep venous thrombosis and right lumbar vein thrombosis based on an abdominal CT scan. This was associated with a likely congenital inferior vena cava agenesis. This malformation is present in approximately 5% of patients with deep vein thrombosis even though it represents a rare cause of portal thrombosis. The fact that several thromboses developed simultaneously makes this a unique and isolated case in the current literature as no similar cases have been reported thus far.

  9. Rosuvastatin reduced deep vein thrombosis in ApoE gene deleted mice with hyperlipidemia through non-lipid lowering effects

    PubMed Central

    Patterson, K.A.; Zhang, X.; Wrobleski, S.K.; Hawley, A.E.; Lawrence, D. A.; Wakefield, T.W.; Myers, D.D.; Diaz, J.A.

    2013-01-01

    Introduction Statins, particularly rosuvastatin, have recently become relevant in the setting of venous thrombosis. The objective of this study was to study the non-lipid lowering effects of rosuvastatin in venous thrombosis in mice with hyperlipidemia. Materials and Methods An inferior vena cava ligation model of venous thrombosis in mice was utilized. Saline or 5mg/kg of rosuvastatin was administered by gavage 48hs previous thrombosis. Blood, the inferior vena cava, thrombus, and liver were harvested 3, 6 hours, and 2 days post-thrombosis. Thrombus weight, inflammatory markers, and plasminogen activator inhibitor-1 expression and plasma levels were measured and neutrophil migration to the IVC was assessed. Results Rosuvastatin significantly decreased thrombus weight, plasminogen activator inhibitor-1 expression and plasma levels, expression of molecules related to the interleukin-6 pathway, and neutrophil migration into the vein wall. Conclusions This work supports the beneficial effects of rosuvastatin on venous thrombosis in mice with hyperlipidemia due to its non-lipid lowering effects. PMID:23276528

  10. Impact of the introduction of emergency ultrasound to one large UK emergency department: the REBUS study.

    PubMed

    Kwok, T'ng Choong; Johnson, Sue; Reed, Matthew James

    2013-02-01

    Firstly, to detail the experiences of one UK training region in establishing an emergency ultrasound (EU) training programme and secondly, to report the initial 30 months of EU scanning experience. Prospective study of all documented emergency department (ED) ultrasound scans. Results were extracted from written paper reports and/or electronically saved images. Details of scan date, time, type of scan, grade of operator, supervision status (whether supervised by a level 1 competent scanner) and whether the scan was clinical (performed or supervised by a level 1 operator) or training, were recorded. EU scans were reviewed for quality (internal quality assurance) and for diagnostic accuracy (external quality assurance). Between 14 January 2009 and 4 July 2011, 626 scans were performed by 41 operators. 263 (42%) scans were completed outside of normal working hours (09:00 to 17:00). There were 251 abdominal aorta and inferior vena cava scans (40% of all scans) and 198 focused assessment with sonography in trauma scans (32%). The number of scans performed by each operator varied widely. 87 scans (14%) were supervised but the majority (459; 73%) were not. 484 (77%) scans were for training purposes, 124 (20%) were clinical scans and the majority (401; 63%) were performed by either speciality registrars (ST4-6) or specialist registrars (SpR). When the three commonest types of scans performed were analysed, eight false positives and 11 false negatives were identified. Only seven of these were deemed of poor quality and none led to poor patient outcome. Since the acquisition of our ED ultrasound machine and the development of a quality assured training programme, on average 20 scans per month have been performed in the ED, with no known adverse patient outcomes.

  11. Prioritizing Information for Quality Improvement Using Resident Assessment Instrument Data: Experiences in One Canadian Province

    PubMed Central

    Sales, Anne; O'Rourke, Hannah M.; Draper, Kellie; Teare, Gary F.; Maxwell, Colleen

    2011-01-01

    Purpose: To elicit priority rankings of indicators of quality of care among providers and decision-makers in continuing care in Alberta, Canada. Methods: We used modified nominal group technique to elicit priorities and criteria for prioritization among the quality indicators and resident/client assessment protocols developed by the interRAI consortium for use in long-term care and home care. Results: The top-ranked items from the long-term care assessment data were pressure ulcers, pain and incontinence. The top-ranked items from the home care data were pain, falls and proportion of clients at high risk for residential placement. Participants considered a variety of issues in deciding how to rank the indicators. Implications: This work reflects the beginning of a process to better understand how providers and policy makers can work together to assess priorities for quality improvement within continuing care. PMID:22294992

  12. Quality from a Toddler's Perspective: A Bottom-Up Examination of Classroom Experiences

    ERIC Educational Resources Information Center

    Hallam, Rena; Fouts, Hillary; Bargreen, Kaitlin; Caudle, Lori

    2009-01-01

    Defining and measuring quality in group care settings has become a central issue in the field of early care and education in the United States, particularly as states develop systems to improve child care quality. Most research and policy definitions of quality rely on a top-down perspective focusing on structural and environmental features of the…

  13. Michigan's Top-to-Bottom Ranking: A Measure of School Quality or Student Poverty?

    ERIC Educational Resources Information Center

    Spalding, Audrey

    2013-01-01

    This study examines the state's "Top-to-Bottom" ranking, which has been repeatedly criticized by educators for appearing to be correlated with school poverty rates. Mackinac Center research finds that schools that serve more lower-income students tend to receive lower scores on the TTB list. These results matters because TTB rankings are…

  14. Bleeding Duodenal: Varices Treatment by TIPS and Transcatheter Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lopera, Jorge E.; Arthurs, Blain; Scheuerman, Christian

    2008-03-15

    We describe our clinical experience in 4 patients with portal hypertension who presented with bleeding mesenteric varices originating from the superior mesenteric vein with retrograde filling of collaterals draining into the inferior vena cava. The clinical presentation, imaging findings, and potential therapeutic management are discussed.

  15. Constraints from Water on Mantle Melting and Slab Fluid Composition

    NASA Astrophysics Data System (ADS)

    Plank, T.; Wade, J.

    2005-12-01

    Water drives mantle melting and fluid migration in subduction zones, but most models for these phenomena have been developed without constraints from water measurements in arc magmas. For example, the Central American volcanic arc (CAVA) records systematic variations in La/Yb, Ba/La and d18O, and these proxies have been used to predict the extent of mantle melting during decompression [1] and water-addition [2]. Here we use water concentrations in olivine-hosted melt inclusions from arc tephra, along with estimates derived from a clinopyroxene hygrometer [3], to test different models for mantle melting and slab fluid composition along the CAVA (from Nicaragua to Costa Rica). We use Ti as a proxy for mantle melt fraction (F) and invert H2O concentrations in CAVA magmas to obtain those in the mantle source (H2Oo), as in [4]. The relationship between F and H2Oo is nominally linear for Costa Rica mantle, with wet melting productivity dF/dH2O = 30 (wt%/wt%), higher than that used in [2], but consistent with experimentally-determined and MELTS-calculated productivity at 50 degrees above the dry solidus. This predicts mantle temperature beneath Costa Rica of at least 1350°C, and allows for a small (1-2% F) decompression-melting contribution, relative to the wet melting contribution (8-20% F). The percent of wet melting correlates locally with Ba/La, but not regionally, and so the use of Ba/La as a wet melting proxy [1] should be limited to single volcanoes or clusters. The water content of the CAVA melting region varies from 2500-9000 ppm H2O but does not decrease monotonically from Nicaragua to Costa Rica as does Ba/La. The relationship between H2Oo and Ba/La is thus complex, and requires a large along-strike decrease in Ba/La and H2O/La in the slab fluids towards the southeast. Such variation appears to be driven largely by La concentration, reflecting more dilute fluids (higher H2O/La) beneath Nicaragua and more solute-rich fluids (e.g., sediment melts with high La/ H2O) beneath Costa Rica. [1] Walker, J.A., M.J. Carr, L.C. Patino, C.M. Johnson, M.D. Feigenson, R.L. Ward Contrib. Mineral. Petrol. [2] Eiler, J.M., M.J. Carr, M. Reagan, E. Stolper, 2005. Geochem. Geophys. Geosyst. [3] Plank, T., Benjamin, E., Wade, J., Grove, T.L. 2004. Fall Mtg, AGU. [4] Kelley, K., Plank, T., Newman, S., Stolper, E.M., Grove, TL, Hauri, E. 2005. JGR.

  16. Successful Outflow Reconstruction to Salvage Traumatic Hepatic Vein-Caval Avulsion of a Normothermic Machine Ex-Situ Perfused Liver Graft

    PubMed Central

    Athanasopoulos, Panagiotis G.; Hadjittofi, Christopher; Dharmapala, Arinda Dinesh; Orti-Rodriguez, Rafael Jose; Ferro, Alessandra; Nasralla, David; Konstantinidou, Sofia K.; Malagó, Massimo

    2016-01-01

    Abstract Donor organ shortage continues to limit the availability of liver transplantation, a successful and established therapy of end-stage liver diseases. Strategies to mitigate graft shortage include the utilization of marginal livers and recently ex-situ normothermic machine perfusion devices. A 59-year-old woman with cirrhosis due to primary sclerosing cholangitis was offered an ex-situ machine perfused graft with unnoticed severe injury of the suprahepatic vasculature due to road traffic accident. Following a complex avulsion, repair and reconstruction of all donor hepatic veins as well as the suprahepatic inferior vena cava, the patient underwent a face-to-face piggy-back orthotopic liver transplantation and was discharged on the 11th postoperative day after an uncomplicated recovery. This report illustrates the operative technique to utilize an otherwise unusable organ, in the current environment of donor shortage and declining graft quality. Normothermic machine perfusion can definitely play a role in increasing the graft pool, without compromising the quality of livers who had vascular or other damage before being ex-situ perfused. Furthermore, it emphasizes the importance of promptly and thoroughly communicating organ injuries, as well as considering all reconstructive options within the level of expertise at the recipient center. PMID:27082550

  17. Successful Outflow Reconstruction to Salvage Traumatic Hepatic Vein-Caval Avulsion of a Normothermic Machine Ex-Situ Perfused Liver Graft: Case Report and Management of Organ Pool Challenges.

    PubMed

    Athanasopoulos, Panagiotis G; Hadjittofi, Christopher; Dharmapala, Arinda Dinesh; Orti-Rodriguez, Rafael Jose; Ferro, Alessandra; Nasralla, David; Konstantinidou, Sofia K; Malagó, Massimo

    2016-04-01

    Donor organ shortage continues to limit the availability of liver transplantation, a successful and established therapy of end-stage liver diseases. Strategies to mitigate graft shortage include the utilization of marginal livers and recently ex-situ normothermic machine perfusion devices. A 59-year-old woman with cirrhosis due to primary sclerosing cholangitis was offered an ex-situ machine perfused graft with unnoticed severe injury of the suprahepatic vasculature due to road traffic accident. Following a complex avulsion, repair and reconstruction of all donor hepatic veins as well as the suprahepatic inferior vena cava, the patient underwent a face-to-face piggy-back orthotopic liver transplantation and was discharged on the 11th postoperative day after an uncomplicated recovery. This report illustrates the operative technique to utilize an otherwise unusable organ, in the current environment of donor shortage and declining graft quality. Normothermic machine perfusion can definitely play a role in increasing the graft pool, without compromising the quality of livers who had vascular or other damage before being ex-situ perfused. Furthermore, it emphasizes the importance of promptly and thoroughly communicating organ injuries, as well as considering all reconstructive options within the level of expertise at the recipient center.

  18. Effects of surface coal mining and reclamation on ground water in small watersheds in the Allegheny Plateau, Ohio

    USGS Publications Warehouse

    Eberle, Michael; Razem, A.C.

    1985-01-01

    The hydrologic effects of surface coal mining in unlimited areas is difficult to predict, partly because of a lack of adequate data collected before and after mining and reclamation. In order to help provide data to assess the effects of surface mining on the hydrology of small basins in the coal fields of the eastern United States, the U.S. Bureau of Mines sponsored a comprehensive hydrologic study at three sites in the Ohio part of the Eastern Coal Province. These sites are within the unqlaciated part of the Allegheny Plateau, and are representative of similar coal-producing areas in Kentucky, West Virginia, and Pennsylvania. The U.S. Geological Survey was responsible for the ground-water phase of the study. The aquifer system at each watershed consisted of two localized perched aquifers (top and middle) above a deeper, more regional aquifer. The premining top aquifer was destroyed by mining in each case, and was replaced by spoils during reclamation. The spoils formed new top aquifers that were slowly becoming resaturated at the end of the study period. Water levels in the aquifers were about the same after reclamation as before mining, although levels rose in a few places. It appears that the underclay at the base of the new top aquifers at all three sites prevents significant downward leakage from the top aquifers to lower except in places where the layer may have been damaged during mining. Water in the top aquifers is a calcium sulfate type, whereas calcium bicarbonate type water predominated before mining. The median specific conductance of water in the new top aquifers was about 5 times greater than that of the original top aquifers in two of the watersheds, and 1 1/2 times the level of the original top aquifers in the third. Concentrations of dissolved sulfate, iron, and manganese in the top aquifers before mining generally did not exceed U.S. and Ohio Environmental Protection Agency drinking-water limits, but generally exceeded these limits after reclamation. Water-quality changes in the middle aquifers were minor by comparison. Water levels and water quality in the deeper, regional aquifers were unaffected by mining.

  19. School Quality, Educational Inequality and Economic Growth

    ERIC Educational Resources Information Center

    Rao, Ramesh; Jani, Rohana bt

    2008-01-01

    Realizing the importance of education in developing a country, many governments had begun to pay more attention in improving the education quality in their country. However whether the desired level of education quality is equally distributed is still debated on. On top of that, current literature on which level of education, either basic or…

  20. Teaching Quality Management Model for the Training of Innovation Ability and the Multilevel Decomposition Indicators

    ERIC Educational Resources Information Center

    Lu, Xingjiang; Yao, Chen; Zheng, Jianmin

    2013-01-01

    This paper focuses on the training of undergraduate students' innovation ability. On top of the theoretical framework of the Quality Function Deployment (QFD), we propose a teaching quality management model. Based on this model, we establish a multilevel decomposition indicator system, which integrates innovation ability characterized by four…

  1. Characteristics and Quality of Autism Websites

    ERIC Educational Resources Information Center

    Reichow, Brian; Halpern, Jason I.; Steinhoff, Timothy B.; Letsinger, Nicole; Naples, Adam; Volkmar, Fred R.

    2012-01-01

    The World Wide Web is a common method for obtaining information on autism spectrum disorders, however, there are no guidelines for finding websites with high quality. We conducted two studies examining the characteristics and/or quality of autism websites in 2009 and 2010. We found websites with a .gov top-level domain had a statistically…

  2. Pharmaceutical research in the Kingdom of Saudi Arabia: A scientometric analysis during 2001–2010

    PubMed Central

    Alhaider, Ibrahim; Mueen Ahmed, K.K.; Gupta, B.M.

    2013-01-01

    Studies on the performance of Saudi Arabia in the pharmaceutical science research using quantitative and qualitative measures. They analyze the productivity and global publication share and rank of the top 15 countries. The author studies Saudi Arabia’s publications output, growth and citation quality, international collaborative publication share and most important the collaborating partners, contribution and citation impact of its top 15 organizations and authors, productivity patterns of its top publishing journals and characteristics of its highly cited papers. PMID:26106268

  3. Teamwork for Oversight of Processes and Systems (TOPS). Implementation guide for TOPS version 2.0, 10 August 1992

    NASA Technical Reports Server (NTRS)

    Strand, Albert A.; Jackson, Darryl J.

    1992-01-01

    As the nation redefines priorities to deal with a rapidly changing world order, both government and industry require new approaches for oversight of management systems, particularly for high technology products. Declining defense budgets will lead to significant reductions in government contract management personnel. Concurrently, defense contractors are reducing administrative and overhead staffing to control costs. These combined pressures require bold approaches for the oversight of management systems. In the Spring of 1991, the DPRO and TRW created a Process Action Team (PAT) to jointly prepare a Performance Based Management (PBM) system titled Teamwork for Oversight of Processes and Systems (TOPS). The primary goal is implementation of a performance based management system based on objective data to review critical TRW processes with an emphasis on continuous improvement. The processes are: Finance and Business Systems, Engineering and Manufacturing Systems, Quality Assurance, and Software Systems. The team established a number of goals: delivery of quality products to contractual terms and conditions; ensure that TRW management systems meet government guidance and good business practices; use of objective data to measure critical processes; elimination of wasteful/duplicative reviews and audits; emphasis on teamwork--all efforts must be perceived to add value by both sides and decisions are made by consensus; and synergy and the creation of a strong working trust between TRW and the DPRO. TOPS permits the adjustment of oversight resources when conditions change or when TRW systems performance indicate either an increase or decrease in surveillance is appropriate. Monthly Contractor Performance Assessments (CPA) are derived from a summary of supporting system level and process-level ratings obtained from objective process-level data. Tiered, objective, data-driven metrics are highly successful in achieving a cooperative and effective method of measuring performance. The teamwork-based culture developed by TOPS proved an unequaled success in removing adversarial relationships and creating an atmosphere of continuous improvement in quality processes at TRW. The new working relationship does not decrease the responsibility or authority of the DPRO to ensure contract compliance and it permits both parties to work more effectively to improve total quality and reduce cost. By emphasizing teamwork in developing a stronger approach to efficient management of the defense industrial base TOPS is a singular success.

  4. Efficiently Selecting the Best Web Services

    NASA Astrophysics Data System (ADS)

    Goncalves, Marlene; Vidal, Maria-Esther; Regalado, Alfredo; Yacoubi Ayadi, Nadia

    Emerging technologies and linking data initiatives have motivated the publication of a large number of datasets, and provide the basis for publishing Web services and tools to manage the available data. This wealth of resources opens a world of possibilities to satisfy user requests. However, Web services may have similar functionality and assess different performance; therefore, it is required to identify among the Web services that satisfy a user request, the ones with the best quality. In this paper we propose a hybrid approach that combines reasoning tasks with ranking techniques to aim at the selection of the Web services that best implement a user request. Web service functionalities are described in terms of input and output attributes annotated with existing ontologies, non-functionality is represented as Quality of Services (QoS) parameters, and user requests correspond to conjunctive queries whose sub-goals impose restrictions on the functionality and quality of the services to be selected. The ontology annotations are used in different reasoning tasks to infer service implicit properties and to augment the size of the service search space. Furthermore, QoS parameters are considered by a ranking metric to classify the services according to how well they meet a user non-functional condition. We assume that all the QoS parameters of the non-functional condition are equally important, and apply the Top-k Skyline approach to select the k services that best meet this condition. Our proposal relies on a two-fold solution which fires a deductive-based engine that performs different reasoning tasks to discover the services that satisfy the requested functionality, and an efficient implementation of the Top-k Skyline approach to compute the top-k services that meet the majority of the QoS constraints. Our Top-k Skyline solution exploits the properties of the Skyline Frequency metric and identifies the top-k services by just analyzing a subset of the services that meet the non-functional condition. We report on the effects of the proposed reasoning tasks, the quality of the top-k services selected by the ranking metric, and the performance of the proposed ranking techniques. Our results suggest that the number of services can be augmented by up two orders of magnitude. In addition, our ranking techniques are able to identify services that have the best values in at least half of the QoS parameters, while the performance is improved.

  5. Teamwork for Oversight of Processes and Systems (TOPS). Implementation guide for TOPS version 2.0, 10 August 1992

    NASA Astrophysics Data System (ADS)

    Strand, Albert A.; Jackson, Darryl J.

    As the nation redefines priorities to deal with a rapidly changing world order, both government and industry require new approaches for oversight of management systems, particularly for high technology products. Declining defense budgets will lead to significant reductions in government contract management personnel. Concurrently, defense contractors are reducing administrative and overhead staffing to control costs. These combined pressures require bold approaches for the oversight of management systems. In the Spring of 1991, the DPRO and TRW created a Process Action Team (PAT) to jointly prepare a Performance Based Management (PBM) system titled Teamwork for Oversight of Processes and Systems (TOPS). The primary goal is implementation of a performance based management system based on objective data to review critical TRW processes with an emphasis on continuous improvement. The processes are: Finance and Business Systems, Engineering and Manufacturing Systems, Quality Assurance, and Software Systems. The team established a number of goals: delivery of quality products to contractual terms and conditions; ensure that TRW management systems meet government guidance and good business practices; use of objective data to measure critical processes; elimination of wasteful/duplicative reviews and audits; emphasis on teamwork--all efforts must be perceived to add value by both sides and decisions are made by consensus; and synergy and the creation of a strong working trust between TRW and the DPRO. TOPS permits the adjustment of oversight resources when conditions change or when TRW systems performance indicate either an increase or decrease in surveillance is appropriate. Monthly Contractor Performance Assessments (CPA) are derived from a summary of supporting system level and process-level ratings obtained from objective process-level data. Tiered, objective, data-driven metrics are highly successful in achieving a cooperative and effective method of measuring performance. The teamwork-based culture developed by TOPS proved an unequaled success in removing adversarial relationships and creating an atmosphere of continuous improvement in quality processes at TRW. The new working relationship does not decrease the responsibility or authority of the DPRO to ensure contract compliance and it permits both parties to work more effectively to improve total quality and reduce cost. By emphasizing teamwork in developing a stronger approach to efficient management of the defense industrial base TOPS is a singular success.

  6. Natural ventilation without air breathing in the top openings of highway tunnels

    NASA Astrophysics Data System (ADS)

    Jin, Sike; Jin, Jiali; Gong, Yanfeng

    2017-05-01

    A number of urban shallow-buried highway tunnels have been built in China. Despite much better internal air quality compared to the traditional tunnels, there is no sufficient theoretical ground or experimental support for the construction of such tunnels. Most researchers hold that natural ventilation in such tunnels depends on air breathing in the top openings, but some others are skeptical about this conclusion. By flow visualization technology on a tunnel experiment platform, we tested the characteristics of airflow in the top openings of highway tunnels. The results showed that air always flowed from outside to inside in all top openings above a continuous traffic stream, and the openings did not breathe at all. In addition, intake air in the top openings reached its maximum velocity at the tunnel entrance, and then gradually slowed down with tunnel depth increasing.

  7. Blending Key Ingredients to Assure Quality in Home Health Care.

    ERIC Educational Resources Information Center

    Griffith, Deloris G.

    1986-01-01

    Careful staff selection, training, and review are among the methods the author recommends to home care agencies striving to provide top-notch services. Discusses measuring the quality of care employees are providing, accreditation, and the benefits of accreditation. (CT)

  8. The Quality Revolution in Education.

    ERIC Educational Resources Information Center

    Bonstingl, John Jay

    1992-01-01

    Whether viewed through Deming's 14 points, Juran's Trilogy, or Kaoru Ishikawa's Thought Revolution, Total Quality Management embodies 4 fundamental tenets: primary focus on customers and suppliers, universal commitment to continuous improvement, a systems approach, and top management responsibility. Educational organizations are recreating their…

  9. Perforation of the heart by an inferior vena cava filter.

    PubMed

    Bolton, J W; Aldea, G S

    1994-04-01

    The use of vena caval filters to prevent pulmonary emboli has become routine. Although the complications have been well described, we present the first reported case of perforation of the heart and subsequent cardiac tamponade several months following placement of a Gintureo-Roehm "bird's nest" filter.

  10. Diaphragmatic hernia and right-sided heart enlargement in a Florida manatee (Trichechus manatus latirostris).

    PubMed

    Gerlach, Trevor J; de Wit, Martine; Landolfi, Jennifer A

    2012-10-01

    Postmortem evaluation of a Florida manatee (Trichechus manatus latirostris) revealed cold stress lesions and previous watercraft trauma that included broken ribs, a diaphragmatic hernia, an enlarged vena cava, and right-sided cardiomegaly. We discuss these findings and present a possible pathogenesis for the cardiomegaly.

  11. Ultrasonography of the liver, spleen, and urinary tract of the cheetah (Acinonyx jubatus).

    PubMed

    Carstens, Ann; Kirberger, Robert M; Spotswood, Tim; Wagner, Wencke M; Grimbeek, Richard J

    2006-01-01

    Diseases of the abdomen of the cheetah (Acinonyx jubatus) include those affecting the liver, spleen, and urinary tract. The most common diseases of captive-bred cheetah are gastritis, gastric ulceration, glomerulosclerosis, and hepatic veno-occlusive disease, and are the most frequent causes of mortality in these animals. The purpose of this study was to describe the ultrasonographic anatomy of the normal liver, spleen, kidney, and urinary bladder of the anesthetized captive-bred cheetah. Twenty-one cheetahs were examined. Eight of the 21 animals had subclinical evidence of either gastritis or chronic renal disease. The ultrasonographic appearances of the liver, gall bladder, common bile duct, and spleen were evaluated and various measurements made. Statistical analyses of the measurements were performed on all the healthy and subclinically ill animals taking sex, age, mass, and anesthetic protocol into account. There were no significant differences in any parameters between the healthy and subclinically ill animals (P > 0.25) and data were combined for statistical analyses. The mean mass was 41.1kg ( +/- 8.8) and the mean age was 5.0 years (+/- 2.2). The mean thickness of the liver medial to the gall bladder was 67.0 mm (+/- 14.8) and the liver was within the left costal arch in 75% of animals, extended caudal to the right costal arch in 50% of animals for an average of 30 mm, and extended caudal to the sternum in 63% of animals for an average of 32.5 mm. The maximum mean hepatic vein diameter at the entrance to the caudal vena cava was 8.6 +/- 2.8 mm; the mean diameters of the portal vein at the hilus and that of the caudal vena cava as it entered the liver were 7.5 +/- 1.6 and 9.9 +/- 4.1 mm, respectively. The mean diameter of the caudal vena cava was significantly affected by the type of anesthetic used (P < 0.10). The mass of the animals was significant in explaining the variance in maximum portal vein diameters (P < 0.10). The mean maximum velocity of the hepatic vein flow at the entrance to the caudal vena cava was 25.3 +/- 2.8 cm/s (n=4), the hilar portal vein was 11.7 +/- 3.3 cm/s (n=7), and the caudal vena cava was 33.8 +/- 19.8 cm/s (n=5). The mean maximum gall bladder length and width, and the mean common bile duct diameters were 44.6 mm (+/- 10.4), 23.3 mm (+/- 5.0), and 8.1 mm (+/- 2.4), respectively. Age was significant in explaining the variance in gall bladder lengths (P<0.10). Urinary tract ultrasonography was performed only in animals that had normal urea and creatinine levels (n=13). Renal cortico-medullary distinction was present in all kidneys and a cortico-medullary rim sign was seen in 21 of 26 kidneys. Mean kidney length, height, and width was 63.9 +/- 5.7, 38.1 +/- 5.2, and 42.1 +/- 5 mm, respectively. The average resistivity index was 0.58 (n=5). Mean urinary bladder length, height, and width were 57.0, 19.2, and 34.9 mm, respectively.

  12. Top management leadership style and quality of care in nursing homes.

    PubMed

    Castle, Nicholas G; Decker, Frederic H

    2011-10-01

    The purpose of this study was to examine the association of Nursing Home Administrator (NHA) leadership style and Director of Nursing (DON) leadership style with quality of care. Leaders were categorized into 4 groups: consensus managers, consultative autocrats, shareholder managers, or autocrats. This leadership style assessment came from primary data collected from approximately 4,000 NHAs and DONs that was linked to quality information (i.e., Nursing Home Compare Quality Measures and 5-Star rating scores) and nursing home information (i.e., Online Survey, Certification, And Reporting data). A consensus manager leadership style has a strong association with better quality. Top managers using this style solicit and act upon input from their employees. For NHAs exhibiting this leadership style, the coefficients on 5 of the 7 quality indicators are statistically significant, and all 7 are significant when the DON exhibits this style. When the NHA and DON both have a consensus manager leadership style, 6 of the 7 quality indicator coefficients are significantly associated with better quality. The findings indicate that NHA and DON leadership style is associated with quality of care. Leadership strategies are amenable to change; thus, the findings of this study may be used to develop policies for promoting more effective leadership in nursing homes.

  13. Why African American College Students Miss the Perfect Test Score

    ERIC Educational Resources Information Center

    Gentry, Ruben; Stokes, Dorothy

    2016-01-01

    Many African Americans were imbued with the cliché that they must work twice as hard as others to be a success in life. Entering college, students with this belief put extensive effort into earning top grades to ensure quality preparation for their chosen career; yet, some fail to earn top scores. Why? This is the million dollar question, but the…

  14. Effects of stand density on top height estimation for ponderosa pine

    Treesearch

    Martin Ritchie; Jianwei Zhang; Todd Hamilton

    2012-01-01

    Site index, estimated as a function of dominant-tree height and age, is often used as an expression of site quality. This expression is assumed to be effectively independent of stand density. Observation of dominant height at two different ponderosa pine levels-of-growing-stock studies revealed that top height stability with respect to stand density depends on the...

  15. Race to the Top--Early Learning Challenge: An Analysis of Impact on IDEIA, Part C Early Intervention Programs

    ERIC Educational Resources Information Center

    Bohjanen, Sharon L.

    2016-01-01

    Infants and toddlers who live in poverty are more likely to experience developmental delays or disabilities and less likely to access early intervention (EI) services. The federal initiative Race to the Top--Early Learning Challenge (RTT-ELC) was designed to increase access to high quality early learning programs for children at risk for…

  16. Validation of Splicing Events in Transcriptome Sequencing Data

    PubMed Central

    Kaisers, Wolfgang; Ptok, Johannes; Schwender, Holger; Schaal, Heiner

    2017-01-01

    Genomic alignments of sequenced cellular messenger RNA contain gapped alignments which are interpreted as consequence of intron removal. The resulting gap-sites, genomic locations of alignment gaps, are landmarks representing potential splice-sites. As alignment algorithms report gap-sites with a considerable false discovery rate, validations are required. We describe two quality scores, gap quality score (gqs) and weighted gap information score (wgis), developed for validation of putative splicing events: While gqs solely relies on alignment data wgis additionally considers information from the genomic sequence. FASTQ files obtained from 54 human dermal fibroblast samples were aligned against the human genome (GRCh38) using TopHat and STAR aligner. Statistical properties of gap-sites validated by gqs and wgis were evaluated by their sequence similarity to known exon-intron borders. Within the 54 samples, TopHat identifies 1,000,380 and STAR reports 6,487,577 gap-sites. Due to the lack of strand information, however, the percentage of identified GT-AG gap-sites is rather low. While gap-sites from TopHat contain ≈89% GT-AG, gap-sites from STAR only contain ≈42% GT-AG dinucleotide pairs in merged data from 54 fibroblast samples. Validation with gqs yields 156,251 gap-sites from TopHat alignments and 166,294 from STAR alignments. Validation with wgis yields 770,327 gap-sites from TopHat alignments and 1,065,596 from STAR alignments. Both alignment algorithms, TopHat and STAR, report gap-sites with considerable false discovery rate, which can drastically be reduced by validation with gqs and wgis. PMID:28545234

  17. Trophic cascades of bottom-up and top-down forcing on nutrients and plankton in the Kattegat, evaluated by modelling

    NASA Astrophysics Data System (ADS)

    Petersen, Marcell Elo; Maar, Marie; Larsen, Janus; Møller, Eva Friis; Hansen, Per Juel

    2017-05-01

    The aim of the study was to investigate the relative importance of bottom-up and top-down forcing on trophic cascades in the pelagic food-web and the implications for water quality indicators (summer phytoplankton biomass and winter nutrients) in relation to management. The 3D ecological model ERGOM was validated and applied in a local set-up of the Kattegat, Denmark, using the off-line Flexsem framework. The model scenarios were conducted by changing the forcing by ± 20% of nutrient inputs (bottom-up) and mesozooplankton mortality (top-down), and both types of forcing combined. The model results showed that cascading effects operated differently depending on the forcing type. In the single-forcing bottom-up scenarios, the cascade directions were in the same direction as the forcing. For scenarios involving top-down, there was a skipped-level-transmission in the trophic responses that was either attenuated or amplified at different trophic levels. On a seasonal scale, bottom-up forcing showed strongest response during winter-spring for DIN and Chl a concentrations, whereas top-down forcing had the highest cascade strength during summer for Chl a concentrations and microzooplankton biomass. On annual basis, the system was more bottom-up than top-down controlled. Microzooplankton was found to play an important role in the pelagic food web as mediator of nutrient and energy fluxes. This study demonstrated that the best scenario for improved water quality was a combined reduction in nutrient input and mesozooplankton mortality calling for the need of an integrated management of marine areas exploited by human activities.

  18. Quality and accuracy of publicly accessible cancer-related physical activity information on the Internet: a cross-sectional assessment.

    PubMed

    Buote, R D; Malone, S D; Bélanger, L J; McGowan, E L

    2016-09-01

    In this study, we assessed the quality of publicly available cancer-related physical activity (PA) information appearing on reputable sites from Canada and other English-speaking countries. A cross-sectional Internet search was conducted on select countries (Canada, USA, Australia, New Zealand, UK) using Google to generate top 50 results per country for the keywords "'physical activity' AND 'cancer'". Top results were assessed for quality of PA information based on a coding frame. Additional searches were performed for Canadian-based sites to produce an exhaustive list. Results found that many sites offered cancer-related PA information (94.5%), but rarely defined PA (25.2%). Top 50 results from each country did not differ on any indicator examined. The exhaustive list of Canadian sites found that many sites gave information about PA for survivorship (78.3%) and prevention (70.0%), but rarely defined (6.7%) or referenced PA guidelines (28.3%). Cancer-related PA information is plentiful on the Internet but the quality needs improvement. Sites should do more than mention PA; they should provide definitions, examples and guidelines. With improvements, these websites would enable healthcare providers to effectively educate their patients about PA, and serve as a valuable resource to the general public who may be seeking cancer-related PA information. © 2016 John Wiley & Sons Ltd.

  19. Forest survey results for higher grade hardwood sawtimber

    Treesearch

    Roy C. Beltz

    1991-01-01

    The 1987 Forest Survey of Mississippi shows a slight increase in forest area and a substantial gain in hardwood inventory. Hardwood gains, appearing in all diameter classes, suggest an increase in quality but hardwood users generally believe quality is declining. By our analysis, volume of top quality hardwood declined while volume in other grades increased. Forest...

  20. Grading the States. Quality Counts. Education Week. Volume 37, Number 17

    ERIC Educational Resources Information Center

    Education Week, 2018

    2018-01-01

    This 22nd edition of "Quality Counts" offers a fresh take on the annual top-to-bottom ranking of the nation's school systems on a state-by-state basis published by "Education Week". The first of three "Quality Counts" reports being rolled out over the course of the year, "Grading the States" aims to…

  1. The Total Quality Classroom.

    ERIC Educational Resources Information Center

    Bonstingl, John Jay

    1992-01-01

    Deming's quality-focused principles contradict Taylor's top-down, authoritarian industrial model. Deming advises educators to fix the system instead of blaming individual teachers for student apathy and low achievement. In the new paradigm, education will be a process that encourages continual progress through improving one's abilities, expanding…

  2. The cost of a "bad hire:" how search firms can help.

    PubMed

    O'Connor, S J

    1991-10-01

    What's the key to competitive advantage and total quality management? O'Connor believes it's hiring top-quality people that are a "good fit" with your organization, and he tells how a search firm can help you do just that.

  3. NASA total quality management 1989 accomplishments report

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Described here are the accomplishments of NASA as a result of the use of Total Quality Management (TQM). The principles in practice which led to these process refinements are important cultural elements to any organization's productivity and quality efforts. The categories of TQM discussed here are top management leadership and support, strategic planning, focus on the customer, employee training and recognition, employee empowerment and teamwork, measurement and analysis, and quality assurance.

  4. Analysis of apple beverages treated with high-power ultrasound: a quality function deployment approach.

    PubMed

    Režek Jambrak, Anet; Šimunek, Marina; Grbeš, Franjo; Mandura, Ana; Djekic, Ilija

    2018-04-01

    The objective of this paper was to demonstrate application of quality function deployment in analysing effects of high power ultrasound on quality properties of apple juices and nectars. In order to develop a quality function deployment model, joint with instrumental analysis of treated samples, a field survey was performed to identify consumer preferences towards quality characteristics of juices/nectar. Based on field research, the three most important characteristics were 'taste' and 'aroma' with 28.5% of relative absolute weight importance, followed by 'odour' (16.9%). The quality function deployment model showed that the top three 'quality scores' for apple juice were treatments with amplitude 90 µm, 9 min treatment time and sample temperature 40 °C; 60 µm, 9 min, 60 °C; and 90 µm, 6 min, 40 °C. For nectars, the top three were treatments 120 µm, 9 min, 20 °C; 60 µm, 9 min, 60 °C; and A2.16 60 µm, 9 min, 20 °C. This type of quality model enables a more complex measure of large scale of different quality parameters. Its simplicity should be understood as its practical advantage and, as such, this tool can be a part of design quality when using novel preservation technologies. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Effect of interfacial intermixing on the Dzyaloshinskii-Moriya interaction in Pt/Co/Pt

    NASA Astrophysics Data System (ADS)

    Wells, Adam W. J.; Shepley, Philippa M.; Marrows, Christopher H.; Moore, Thomas A.

    2017-02-01

    We study the effect of sputter-deposition conditions, namely, substrate temperature and chamber base pressure, upon the interface quality of epitaxial Pt/Co/Pt thin films with perpendicular magnetic anisotropy. Here we define interface quality to be the inverse of the sum in quadrature of roughness and intermixing. We find that samples with the top Co/Pt layers grown at 250 ∘C exhibit a local maximum in roughness intermixing and that the interface quality is better for lower or higher deposition temperatures, up to 400 ∘C,above which the interface quality degrades. Imaging the expansion of magnetic domains in an in-plane field using wide-field Kerr microscopy, we determine the interfacial Dzyaloshinskii-Moriya interaction (DMI) in films in the deposition temperature range 100 ∘C to 300 ∘C . We find that the net DMI increases as the difference between top and bottom Co interface quality increases. Furthermore, for sufficiently low base pressures, the net DMI increases linearly with the deposition temperature, indicating that fine-tuning of the DMI may be achieved via the deposition conditions.

  6. Quality assurance in materials and construction

    DOT National Transportation Integrated Search

    2007-06-01

    This review is a product of the FHWA 2006, National Review Program (NRP). Quality Assurance (QA) was selected for review in 2006 because the program was ranked as one of the top five areas of interest for review by FHWA. Over the last 10 years an ave...

  7. Applying Continuous Quality Improvement Principles in Secondary School Vocational Education, with Emphasis on Special Populations.

    ERIC Educational Resources Information Center

    McLean, Gary N.

    1993-01-01

    Principles of quality management applicable to education for secondary special populations include process orientation, cascading, top commitment, vertical/horizontal communication, continuous improvement, shared vision, primacy of customers, investment in people, constancy of purpose, and shared goal setting. (JOW)

  8. Search engine ranking, quality, and content of webpages that are critical vs noncritical of HPV vaccine

    PubMed Central

    Fu, Linda Y.; Zook, Kathleen; Spoehr-Labutta, Zachary; Hu, Pamela; Joseph, Jill G.

    2015-01-01

    Purpose Online information can influence attitudes toward vaccination. The aim of the present study is to provide a systematic evaluation of the search engine ranking, quality, and content of webpages that are critical versus noncritical of HPV vaccination. Methods We identified HPV vaccine-related webpages with the Google search engine by entering 20 terms. We then assessed each webpage for critical versus noncritical bias as well as for the following quality indicators: authorship disclosure, source disclosure, attribution of at least one reference, currency, exclusion of testimonial accounts, and readability level less than 9th grade. We also determined webpage comprehensiveness in terms of mention of 14 HPV vaccine relevant topics. Results Twenty searches yielded 116 unique webpages. HPV vaccine-critical webpages comprised roughly a third of the top, top 5 and top 10-ranking webpages. The prevalence of HPV vaccine-critical webpages was higher for queries that included term modifiers in addition to root terms. Compared with noncritical webpages, webpages critical of HPV vaccine overall had a lower quality score than those with a noncritical bias (p<.01) and covered fewer important HPV-related topics (p<.001). Critical webpages required viewers to have higher reading skills, were less likely to include an author byline, and were more likely to include testimonial accounts. They also were more likely to raise unsubstantiated concerns about vaccination. Conclusion Webpages critical of HPV vaccine may be frequently returned and highly ranked by search engine queries despite being of lower quality and less comprehensive than noncritical webpages. PMID:26559742

  9. Assessing the image quality of pelvic MR images acquired with a flat couch for radiotherapy treatment planning.

    PubMed

    McJury, M; O'Neill, A; Lawson, M; McGrath, C; Grey, A; Page, W; O'Sullivan, J M

    2011-08-01

    To improve the integration of MRI with radiotherapy treatment planning, our department fabricated a flat couch top for our MR scanner. Setting up using this couch top meant that the patients were physically higher up in the scanner and, posteriorly, a gap was introduced between the patient and radiofrequency coil. Phantom measurements were performed to assess the quantitative impact on image quality. A phantom was set up with and without the flat couch insert in place, and measurements of image uniformity and signal to noise were made. To assess clinical impact, six patients with pelvic cancer were recruited and scanned on both couch types. The image quality of pairs of scans was assessed by two consultant radiologists. The use of the flat couch insert led to a drop in image signal to noise of approximately 14%. Uniformity in the anteroposterior direction was affected the most, with little change in right-to-left and feet-to-head directions. All six patients were successfully scanned on the flat couch, although one patient had to be positioned with their arms by their sides. The image quality scores showed no statistically significant change between scans with and without the flat couch in place. Although the quantitative performance of the coil is affected by the integration of a flat couch top, there is no discernible deterioration of diagnostic image quality, as assessed by two consultant radiologists. Although the flat couch insert moved patients higher in the bore of the scanner, all patients in the study were successfully scanned.

  10. Influence of using a blend of rennet casein and whey protein concentrate as protein source on the quality of Mozzarella cheese analogue.

    PubMed

    Dhanraj, Padhiyar; Jana, Atanu; Modha, Hiral; Aparnathi, K D

    2017-03-01

    The effect of incorporating whey protein concentrate (WPC) on the quality characteristics of Mozzarella cheese analogue (MCA) based on rennet casein (RC) was studied. The proportion of RC:WPC tried out were 95:5, 90:10, and 85:15 w/w. The formulation of MCA comprised of 23.5% of blend of RC and WPC, 15% specialty vegetable fat, 2.75% trisodium citrate + disodium hydrogen orthophosphate (2.5:1, w/w), 0.07% calcium chloride, 0.6% citric acid, 1.1% NaCl, 1.5% cheese bud flavoring, and rest water. Varying the proportion of RC and WPC had a significant influence on the composition, textural properties, baking qualities and sensory quality of MCA judged as a topping on pizza pie. MCA made using protein blends (RC:WPC-90:10 or 85:15) behaved satisfactorily during pizza baking trials. However, looking at the superiority of MCA made using RC:WPC (90:10) with regard to shred quality and marginal superiority in terms of the total sensory score of cheese, judged as pizza topping, the former blend (i.e. RC:WPC, 90:10) was selected. The MCA obtained employing such protein blend had composition similar to that of Pizza cheese prepared from cheese milk and had requisite baking characteristics needed as a pizza topping. It is recommended to use a blend of RC and WPC (90:10) as the protein source in the formulation of MCA to obtain nutritionally superior cheese product having desired functional properties for its end use in baking applications.

  11. Beef customer satisfaction: USDA quality grade and marination effects on consumer evaluations of top round steaks.

    PubMed

    Behrends, J M; Goodson, K J; Koohmaraie, M; Shackelford, S D; Wheeler, T L; Morgan, W W; Reagan, J O; Gwartney, B L; Wise, J W; Savell, J W

    2005-03-01

    An in-home beef study evaluated consumer ratings of top round steaks (semimembranosus) as influenced by USDA quality grade (top Choice or high Select), city (Chicago or Philadelphia), consumer segment (beef loyalists = heavy consumers of beef; budget rotators = cost-driven and split meat consumption between beef and chicken; and variety rotators = higher incomes and education and split meat consumption among beef, poultry, and other foods), degree of doneness, cooking method, and marination. Consumers evaluated each steak for overall like, tenderness, juiciness, flavor like, and flavor amount using 10-point scales (1 = dislike extremely, not at all tender, not at all juicy, dislike extremely, and none at all to 10 = like extremely, extremely tender, extremely juicy, like extremely, and an extreme amount of flavor, respectively). Quality grade affected several consumer sensory traits, with top Choice receiving higher (P < or = 0.004) tenderness, juiciness, and flavor like scores than high Select. Consumers in Chicago rated steaks cooked "medium and less" higher for overall like, tenderness, juiciness, flavor like, and flavor amount than those in Philadelphia (city x degree of doneness; P < or = 0.020). Steaks braised by customers in Philadelphia received among the highest scores for overall like, tenderness, juiciness, flavor like, and flavor amount compared with any cooking method used by customers in Chicago (cooking method x city; P < or = 0.026). Overall like and flavor amount ratings were least (P < 0.05) for steaks that were marinated and cooked to "medium and less" degree of doneness (marination x degree of doneness; P < or = 0.014). Braised steaks received among the highest values for overall like, tenderness, juiciness, flavor like, and flavor amount when cooked to "medium and less" or "medium well and more" (cooking method x degree of doneness; P < or = 0.008). Correlation and stepwise regression analysis indicated that flavor like was pivotal in customers' satisfaction with top round steaks, and was the sensory trait most highly correlated to overall like, followed by tenderness, flavor amount, and juiciness. Preparation of top round steaks was crucial in consumers' likes and dislikes, and by improving flavor, higher consumer satisfaction may be achieved.

  12. Arrhythmogenic right ventricular cardiomyopathy in monozygotic twin sisters, and persistent left superior vena cava in one complicating implantation of ICD.

    PubMed

    Astarcıoğlu, Mehmet Ali; Yaymacı, Mehmet; Şen, Taner; Kilit, Celal; Amasyalı, Basri

    2015-10-01

    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy characterized histologically by fibro-fatty replacement of heart muscle, and clinically by ventricular arrhythmias and right ventricular dysfunction. This report presents monozygotic twins with ARVC, suggesting a genetic abnormality as the most probable cause.

  13. Characterization of Human Torso Vascular Morphometry in Normotensive and Hypotensive Trauma Patients

    DTIC Science & Technology

    2015-07-01

    Aorta Wall Measures Merged for Analysis Landmarks & User-aided Segmentation 5cm Volume...with Centerline Measures AORTA PROCESSING VENA CAVA PROCESSING Basic Morphomics Scan Identification Aorta Centerline Segmented Aorta and Vena...Analysis 49 Data Presentation Aorta  Radius  Popula/on       Normotensive   Hypotensive  

  14. Total anomalous systemic with partial anomalous pulmonary venous connections.

    PubMed

    Vallath, Gopakumar; Gajjar, Trushar; Desai, Neelam

    2013-12-01

    A 9-year-old girl with cyanosis, dyspnea, and grade II clubbing was diagnosed by contrast transthoracic echocardiography and angiocardiography to have an anomalous connection of the venae cavae to the physiologic left atrium with partial anomalous pulmonary venous connection. Successful surgical correction was achieved, and the patient's recovery was uneventful.

  15. Thromboembolic diseases and the use of vena cava filters.

    PubMed

    De Silva, Samanthi

    2017-04-01

    Mr GW is a 77-year-old gentleman who is hoping to have a total knee replacement of his left knee. He underwent a knee replacement on the right in 2011 under spinal anaesthetic, where his postoperative period was complicated by a saddle pulmonary embolus (PE). Copyright the Association for Perioperative Practice.

  16. Braile Vena Cava Filter and Greenfield Filter in Terms of Centralization

    PubMed Central

    de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon

    2013-01-01

    The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter’s symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry. PMID:23459189

  17. Braile vena cava filter and greenfield filter in terms of centralization.

    PubMed

    de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon

    2013-01-01

    The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.

  18. Cement pulmonary embolism after vertebroplasty.

    PubMed

    Sifuentes Giraldo, Walter Alberto; Lamúa Riazuelo, José Ramón; Gallego Rivera, José Ignacio; Vázquez Díaz, Mónica

    2013-01-01

    In recent years, the use of vertebral cementing techniques for vertebroplasty and kyphoplasty has spread for the treatment of pain associated with osteoporotic vertebral compression fractures. This is also associated with the increased incidence of complications related with these procedures, the most frequent being originated by leakage of cementation material. Cement can escape into the vertebral venous system and reach the pulmonary circulation through the azygous system and cava vein, producing a cement embolism. This is a frequent complication, occurring in up to 26% of patients undergoing vertebroplasty but, since most patients have no clinical or hemodynamical repercussion, this event usually goes unnoticed. However, some serious, and even fatal cases, have been reported. We report the case of a 74-year-old male patient who underwent vertebroplasty for persistent pain associated with osteoporotic L3 vertebral fracture and who developed a cement leak into the cava vein and right pulmonary artery during the procedure. Although he developed a pulmonary cement embolism, the patient remained asymptomatic and did not present complications during follow-up. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  19. Persistent left superior vena cava in association with sinus venosus defect type of atrial septal defect and partial pulmonary venous return on 64-MDCT

    PubMed Central

    Disha, Bansal; Prakashini, Koteshwara; Shetty, Ranjan K

    2014-01-01

    The most common venous abnormality of the thorax is persistent left superior vena cava (PLSVC), incidence being less than 0.5%. However, with congenital heart disease, it is about 6.1%. When the coronary sinus is dilated always search for PLSVC. The coronary sinus may communicate with the left atrium. This is known as an unroofed coronary sinus (UCS) and preoperatively documenting it is important. Of all the congenital cardiac anomalies, the sinus venosus defect (SVD) type of atrial septal defect (ASD) is most commonly associated with PLSVC and accounts for 4–11% of all ASDs. Multidetector CT can easily show all these abnormalities along with haemodynamics. On transoesophageal echocardiography it is difficult to characterise SVD and visualise a coronary sinus because of a limited window, contrast resolution and poor patient compliance. The complex of UCS and PLSVC is one such abnormality and its treatment requires careful assessment of other concomitant cardiac abnormalities to prevent post-treatment haemodynamic complications. PMID:24850552

  20. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juszkat, Robert, E-mail: radiologiamim@wp.p; Pukacki, Fryderyk; Zarzecka, Anna

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The proceduremore » was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.« less

  1. Percutaneous closure of a hemodynamically significant connection between the inferior vena cava and the left atrium.

    PubMed

    Wiebe, Jens; Rixe, Johannes; Nef, Holger

    2015-10-01

    A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.

  2. Accessory hepatic vein complicating extra-cardiac total cavopulmonary connection.

    PubMed

    Yoshii, Shinpei; Suzuki, Shoji; Osawa, Hiroshi; Hosaka, Shigeru; Honda, Yoshihiro; Abraham, Samuel J K; Tada, Yusuke; Sugiyama, Hisashi; Tan, Tetsushi; Kadono, Toshie; Hoshiai, Minako; Komai, Takayuki

    2002-04-01

    We encountered unexpected, severe hypoxia after the right heart bypass operation in a patient with isomerism. A 2-year-old girl with polysplenia had a complex cardiac anomaly consisting of a single atrium, single ventricle, pulmonary stenosis, absence of the right superior vena cava, hemiazygos continuation of the left inferior vena cava, and d-malposition of the great arteries. After a total cavopulmonary shunt, we performed an extra-cardiac total cavo-pulmonary connection with a 14 mm tube graft. The postoperative course was complicated by severe hypoxia. Angiography performed 20 days after the operation showed that contrast medium in the conduit poured into the hepatic vein, and through the intrahepatic communications, it passed into a left-sided accessory hepatic vein, which was connected directly to the left side of the aspect of the atrium. As the intrahepatic communication was adequate, we ligated the accessory hepatic vein within the pericardial cavity. The SpO2 returned to normal and no hepatic dysfunction was detected. We conclude that surgeons performing extra-cardiac total cavopulmonary connection need to pay closer attention to the possibility that an accessory hepatic vein might exist.

  3. Histology of Tissue Adherent to OptEase Inferior Vena Cava Filters Regarding Indwelling Time

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Volkov, Alexander; Garniek, Alexander

    The purpose of this paper is to report on the histology of tissues found on retrieved filters with regard to indwelling time. Between February 2006 and January 2007, 28 Optease inferior vena cava filters (Cordis Europa, Roden, The Netherlands) were retrieved from 27 patients. Twenty-two filters were inserted prophylactically for trauma patients and six for patients with venous thromboembolism. Cavography was performed both before and after filter removal to evaluate the presence of thrombi or wall damage. Filters were retrieved with the snare and sheath method. All material adherents to the filters were examined histologically.The mean indwelling time of themore » filters was 24.9 days (range, 6-69 days). Red tissue fragments were seen on all the filters, consistent microscopically with clots and fibrin. On five filters (18%; mean indwelling time, 45.4 days) white tissue consistent with vascular intima was found. All postprocedure cavographies were normal. We conclude that most material adherent to the retrieved filters is thrombi, while vascular intima can be found in the minority of filters with a longer indwelling time.« less

  4. Mediastinal germ cell tumour causing superior vena cava tumour thrombosis.

    PubMed

    Karanth, Suman S; Vaid, Ashok K; Batra, Sandeep; Sharma, Devender

    2015-03-25

    We report a rare case of a 35-year-old man who presented with a 1-week history of retrosternal chest pain of moderate intensity. A positron emission tomography CT (PET-CT) showed a large fluorodeoxy-glucose (FDG)-avid heterogeneously enhancing necrotic mass in the anterosuperior mediastinum with a focal FDG-avid thrombosis of the superior vena cava (SVC) suggestive of tumour thrombus and vascular invasion. α-Fetoprotein levels were raised (5690 IU/L). Image guided biopsy of the mediastinal mass was suggestive of non-seminomatous germ cell tumour (NSGCT). The patient received four cycles of BEP (bleomycin, etoposide and cisplatin) along with therapeutic anticoagulation with low-molecular-weight heparin. Follow-up whole body PET-CT revealed complete resolution of mediastinal mass and SVC tumour thrombosis. The documentation of FDG-PET-avid tumour thrombus resolving with chemotherapy supports the concept of circulating tumour cells being important not only in common solid tumours such as breast and colon cancer but also in relatively less common tumours such as NSGCT. The detection of circulating tumour cells could help deploy aggressive regimens upfront. 2015 BMJ Publishing Group Ltd.

  5. Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.

    PubMed

    Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H

    1996-03-01

    The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.

  6. Computational Simulations of Inferior Vena Cava (IVC) Filter Placement and Hemodynamics in Patient-Specific Geometries

    NASA Astrophysics Data System (ADS)

    Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent

    2013-11-01

    A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.

  7. Anatomic bifurcated reconstruction of chronic bilateral innominate-superior vena cava occlusion using the Y-stenting technique.

    PubMed

    Amin, Parth; Sharafuddin, Mel J; Laurich, Chad; Nicholson, Rachael M; Sun, Raphael C; Roh, Simon; Kresowik, Timothy F; Sharp, William J

    2012-02-01

    This article presents the case of a 42-year-old man who presented with superior vena cava (SVC) syndrome due to fibrosing mediastinitis with multiple failed attempts at recanalization. We initially treated him with unilateral sharp needle recanalization of the right innominate vein into the SVC stump followed by stenting. Although his symptoms improved immediately, they did not completely resolve. Six months later, he returned with worsening symptoms, and venography revealed in-stent restenosis. The patient requested simultaneous treatment on the left side. The right stent was dilated, and a 3-cm-long occlusion of the left innominate vein was recanalized, again using sharp needle technique, homing into the struts of the right-sided stent. Following fenestration of the stent, a second stent was deployed from the left side into the SVC, and the two Y limbs were sequentially dilated to allow a true bifurcation anatomy (figure). The patient had complete resolution of his symptoms and continues to do well 6 months later. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  8. Thrombus just beneath a retrievable inferior vena cava filter in a pregnant woman with deep vein thrombosis: its removal requiring catheter thrombus fragmentation with fibrinolysis.

    PubMed

    Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki

    2014-02-01

    Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  9. Intra-cardiac Embolism of a Large Bone Cement Material after Percutaneous Vertebroplasty Removed through a Combination of an Endovascular Procedure and an Inferior Vena Cava Exploration: a Case Report.

    PubMed

    Park, Jin-Sung; Kim, Jaedong; Lee, Yonggu; Gwon, Jun-Gyo; Park, Ye-Soo

    2018-05-07

    Percutaneous vertebroplasty (PVP) is a minimally invasive surgical treatment for patients with osteoporotic vertebral compression fracture (OVCF) and can rapidly alleviate pain, improve mobility, and stabilize the vertebrae. However, it has the potential to cause complications such as cement embolism. A 55-year-old female presented with pain in the lumbar region as a chief complaint. PVP was performed after diagnosis of acute OVCFs at L4 and L5. No abnormal symptoms were reported after surgery, but a large cement embolism was observed in her right atrium and ventricle. After discussion in a multi-disciplinary team, the large cement embolism was successfully removed by a combination of endovascular procedure and an inferior vena cava exploration. Surgeons must consider the possibility of intra-cardiac cement embolism after PVP. A hybrid approach of an endovascular procedure and a vascular surgery may be a reasonable treatment option to minimize the surgical procedure in cases of a large intra-cardiac cement embolism.

  10. Primary Renal Rhabdomyosarcoma in an Adolescent With Tumor Thrombosis in the Inferior Vena Cava and Right Atrium: A Case Report and Review of the Literature.

    PubMed

    Lin, Wei-Ching; Chen, Jeon-Hor; Westphalen, Antonio; Chang, Han; Chiang, I-Ping; Chen, Cheng-Hong; Wu, Hsi-Chin; Lin, Chien-Heng

    2016-05-01

    Although the second peak of the age distribution of rhabdomyosarcoma (RMS) is at adolescence, renal RMS is extremely rare at this age group. This tumor is indistinguishable from other renal tumors based on clinical and imaging findings, and the diagnosis relies on histology and immunohistochemical staining. We report a unique case of adolescent renal RMS associated with tumor thrombus extending into the inferior vena cava (IVC) and right atrium.An 18-year-old female adolescent presented with shortness of breath and palpitations, associated with right flank discomfort, and hematuria. A pleomorphic-type renal RMS with Budd-Chiari syndrome and arrhythmia induced by IVC and RA thrombosis was diagnosed. Despite complete tumor resection, the patient developed multiple lung metastases a month after surgery. Chemotherapy was recommended, but the patient declined. She died within a year of the initial operation.Adolescent renal RMS is rare and associated with poor outcome. Early aggressive multimodal therapy seems to be appropriate, in particular, in the presence of tumor thrombosis.

  11. [A complete response to one-shot hepatic arterial infusion of epirubicin in a patient with highly advanced hepatocellular carcinoma].

    PubMed

    Takamatsu, Manabu; Matsuda, Takeru; Kawaguchi, Katsunori; Ku, Yonson

    2007-11-01

    A 61-year-old male was admitted for advanced hepatocellular carcinoma (HCC) with multiple lung metastases and tumor thrombus in the portal vein and superior vena cava. At first, we planned to perform transcatheter arterial embolization (TAE) to avoid the rupture of the liver tumor. But, due to the severe liver dysfunction, ie Child-Pugh C and 36% ICG R15, hepatic arterial infusion (HAI) of epirubicin 40 mg was performed. After that, the patient was followed at the outpatient ward and his general condition has gradually improved without a special treatment. At the present, one year and ten month after HAI, the serum alpha-fetoprotein (AFP) is almost within normal limits and CT scans show that HCC with multiple lung metastases, and tumor thrombus in the portal vein and superior vena cava almost disappeared. Although, spontaneous regression of HCC was a rare phenomenon, it might have played a major role in the good anticancer efficacy of this patient as well as high anti-cancer agent sensitivity of his liver tumor.

  12. Venous drainage of the dorsal sector of the liver: differences between segments I and IX. A study on corrosion casts of the human liver.

    PubMed

    Gadzijev, E M; Ravnik, D; Stanisavljevic, D; Trotovsek, B

    1997-01-01

    The aim of this study was to determine the venous drainage of the dorsal sector of the liver in order to define the differences between segments I and IX and their implications for sectorially and segmentally oriented hepatic surgery. The study was based on corrosion casts of 61 macroscopically healthy livers. The drainage pathways of veins at least 10 mm long and 1 mm wide were evaluated and statistically analysed. On average, 9 veins drained the two segments and three veins from both segments entered the inferior vena cava. In 95% of cases the veins from segment I drained predominantly into the inferior vena cava, whereas in segment IX this pathway was dominant in only 30% of cases. In 64% of cases a vein originating in segment IX entered the right hepatic v. The difference in the venous drainage of the two segments suggests that segment IX partly belongs to the neighbouring segments and may thus be only a paracaval region of the right liver.

  13. Pulmonary endothelial pavement patterns.

    PubMed Central

    Kibria, G; Heath, D; Smith, P; Biggar, R

    1980-01-01

    The appearance of the endothelial pavement pattern was studied in the pulmonary trunk, pulmonary veins, aorta, and inferior vena cava of the rat by means of silver staining of the cell borders. The endothelial cell in each of the four blood vessels was found to have its own distinctive shape, fusiform and pointed in the direction of blood flow in the case of the aorta and larger and more rectangular in the pulmonary trunk and pulmonary veins. Detailed quantitation of the dimensions and surface area of the endothelial cells in each blood vessel was carried out by a photographic technique. Pulmonary hypertension was induced in one group of rats by feeding them on Crotalaria spectabilis seeds. The endothelial pavement pattern in their pulmonary trunks became disrupted with many of the cells assuming a fusiform shape reminiscent of aortic endothelium. Many small, new endothelial cells formed in the pulmonary trunk suggesting division of cells to line the enlarging blood vessels. In contrast the endothelial cells of the inferior vena cava merely increased in size to cope with the dilatation of this vein. Images PMID:7385090

  14. Superior Vena Cava as Gateway to Heart: Metastatic Breast Carcinoma Causing Ball in a Loop Metastasis to Right Atrium.

    PubMed

    Sandhu, Harpreet Singh; Mahendrakar, Sampath Kumar Mahadevappa; Ladhani, Sulaiman Sadruddin; Khan, Azizullah Hafizullah; Loya, Yunus Shafi

    2017-07-01

    Breast carcinoma is the most common invasive cancer in women worldwide. It metastasizes commonly to bone, lungs, regional lymph nodes and brain. Cardiac metastasis of lung and breast cancers is a known but rare complication of advanced disease with tumour metastasising to pericardium via the locoregional lymphatic system. Here we present a case of 59-year-old female presenting with right upper limb oedema, facial puffiness and features of Superior Vena Cava (SVC) syndrome 15 years after mastectomy and adjuvant chemotherapy, radiotherapy for carcinoma of the right breast. Further evaluation revealed extensive thrombus invading the right internal jugular vein, subclavian vein, SVC with intraluminal extension into right atrium causing ball in a loop obstruction at tricuspid valve. Whole body Positron emission tomography scan confirmed the diagnosis of extensive metastatic disease and patient was managed on palliative therapy. Haematogenous spread and intraluminal growth of metastatic deposits from breast carcinoma 15 years ago is rare and clinical presentation as SVC obstruction has not been reported in our review of literature.

  15. Appropriate Importation and Effective Utilization of Top Quality Foreign Higher Education Resources for Sino-Foreign Cooperation in Running Schools

    ERIC Educational Resources Information Center

    Jinhui, Lin; Zhiping, Liu

    2009-01-01

    The appropriate importation and effective utilization of superior-quality foreign higher education resources are crucial to enhance the level and quality of school administration cooperation with foreign partners because it can not only make up for the shortage in domestic education resources and push forward China's higher education reform but…

  16. Spectral CT imaging in patients with Budd-Chiari syndrome: investigation of image quality.

    PubMed

    Su, Lei; Dong, Junqiang; Sun, Qiang; Liu, Jie; Lv, Peijie; Hu, Lili; Yan, Liangliang; Gao, Jianbo

    2014-11-01

    To assess the image quality of monochromatic imaging from spectral CT in patients with Budd-Chiari syndrome (BCS), fifty patients with BCS underwent spectral CT to generate conventional 140 kVp polychromatic images (group A) and monochromatic images, with energy levels from 40 to 80, 40 + 70, and 50 + 70 keV fusion images (group B) during the portal venous phase (PVP) and the hepatic venous phase (HVP). Two-sample t tests compared vessel-to-liver contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) for the portal vein (PV), hepatic vein (HV), inferior vena cava. Readers' subjective evaluations of the image quality were recorded. The highest SNR values in group B were distributed at 50 keV; the highest CNR values in group B were distributed at 40 keV. The higher CNR values and SNR values were obtained though PVP of PV (SNR 18.39 ± 6.13 vs. 10.56 ± 3.31, CNR 7.81 ± 3.40 vs. 3.58 ± 1.31) and HVP of HV (3.89 ± 2.08 vs. 1.27 ± 1.55) in the group B; the lower image noise for group B was at 70 keV and 50 + 70 keV (15.54 ± 8.39 vs. 18.40 ± 4.97, P = 0.0004 and 18.97 ± 7.61 vs. 18.40 ± 4.97, P = 0.0691); the results show that the 50 + 70 keV fusion image quality was better than that in group A. Monochromatic energy levels of 40-70, 40 + 70, and 50 + 70 keV fusion image can increase vascular contrast and that will be helpful for the diagnosis of BCS, we select the 50 + 70 keV fusion image to acquire the best BCS images.

  17. A probability metric for identifying high-performing facilities: an application for pay-for-performance programs.

    PubMed

    Shwartz, Michael; Peköz, Erol A; Burgess, James F; Christiansen, Cindy L; Rosen, Amy K; Berlowitz, Dan

    2014-12-01

    Two approaches are commonly used for identifying high-performing facilities on a performance measure: one, that the facility is in a top quantile (eg, quintile or quartile); and two, that a confidence interval is below (or above) the average of the measure for all facilities. This type of yes/no designation often does not do well in distinguishing high-performing from average-performing facilities. To illustrate an alternative continuous-valued metric for profiling facilities--the probability a facility is in a top quantile--and show the implications of using this metric for profiling and pay-for-performance. We created a composite measure of quality from fiscal year 2007 data based on 28 quality indicators from 112 Veterans Health Administration nursing homes. A Bayesian hierarchical multivariate normal-binomial model was used to estimate shrunken rates of the 28 quality indicators, which were combined into a composite measure using opportunity-based weights. Rates were estimated using Markov Chain Monte Carlo methods as implemented in WinBUGS. The probability metric was calculated from the simulation replications. Our probability metric allowed better discrimination of high performers than the point or interval estimate of the composite score. In a pay-for-performance program, a smaller top quantile (eg, a quintile) resulted in more resources being allocated to the highest performers, whereas a larger top quantile (eg, being above the median) distinguished less among high performers and allocated more resources to average performers. The probability metric has potential but needs to be evaluated by stakeholders in different types of delivery systems.

  18. Particle Pollution

    MedlinePlus

    ... of running) so you don't breathe as hard. Avoid busy roads and highways where PM is usually worse because of emissions from cars and trucks. For more tools to help you learn about air quality, visit Tracking Air Quality . Top of Page File Formats Help: How do I view different file formats ( ...

  19. Beam shaping optics to enhance performance of interferometry techniques in grating manufacture

    NASA Astrophysics Data System (ADS)

    Laskin, Alexander; Laskin, Vadim; Ostrun, Aleksei

    2018-02-01

    Improving of industrial holographic and interferometry techniques is of great importance in interference lithography, computer-generated holography, holographic data storage, interferometry recording of Bragg gratings as well as gratings of various types in semiconductor industry. Performance of mentioned techniques is essentially enhanced by providing a light beam with flat phase front and flat-top irradiance distribution. Therefore, transformation of Gaussian distribution of a TEM00 laser to flat-top (top hat, uniform) distribution is an important optical task. There are different refractive and diffractive beam shaping approaches used in laser industrial and scientific applications, but only few of them are capable to fulfil the optimum conditions for beam quality demanding holography and interferometry. As a solution it is suggested to apply refractive field mapping beam shaping optics πShaper, which operational principle presumes almost lossless transformation of Gaussian to flat-top beam with flatness of output wavefront, conserving of beam consistency, providing collimated low divergent output beam, high transmittance, extended depth of field, negligible wave aberration, and achromatic design provides capability to work with several lasers with different wavelengths simultaneously. High optical quality of resulting flat-top beam allows applying additional optical components to build various imaging optical systems for variation of beam size and shape to fulfil requirements of a particular application. This paper will describe design basics of refractive beam shapers and optical layouts of their applying in holography and laser interference lithography. Examples of real implementations and experimental results will be presented as well.

  20. The contribution of geography to black/white differences in the use of low neonatal mortality hospitals in New York City.

    PubMed

    Hebert, Paul L; Chassin, Mark R; Howell, Elizabeth A

    2011-02-01

    Racial differences in the use of high-quality hospital care contribute to racial disparities in mortality for very low birth weight (VLBW) neonates. We explored the role that geographic distribution of hospitals plays in the racial disparity in the use of top-tier hospitals by mothers of VLBW neonates in New York City. Retrospective analysis of Vital Statistics and administrative databases. VLBW deliveries in New York City from 1996 to 2001 to non-Hispanic Black (n = 4947) and non-Hispanic White (n = 1615) mothers. Black mothers were less likely to deliver in a top-tier hospitals (White = 44%, Black = 28%; P < 0.001) and top-tier hospitals were less likely to be located in Black mothers' neighborhoods (White = 40%, Black = 33%; P < 0.001). Distance, however, did not contribute to the disparity in use of top-tier hospitals. Non-Hispanic Black mothers lived marginally closer to a top-tier hospital than non-Hispanic White mothers (0.65 miles closer; P < 0.001), and mothers of both the races often bypassed their neighborhood hospital (Black = 62% bypassed, White = 71%; P < 0.001). Inattention to recommended prenatal behaviors was associated with using a closer hospital, suggesting that geographic proximity was most important to mothers of vulnerable neonates. Purported measures of hospital quality such as Neonatal Intensive Care Unit level and volume were more strongly associated with use of hospital for White mothers than for Black mothers. The influence of geography on the use of top-tier hospitals for mothers of VLBW neonates is complex. Other personal and hospital characteristics, not just distance or geography, also influenced hospital use in New York City.

  1. Rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating heart failure from pulmonary disease as the cause of acute dyspnea in the emergency setting

    PubMed Central

    2012-01-01

    Background Rapid and accurate diagnosis and management can be lifesaving for patients with acute dyspnea. However, making a differential diagnosis and selecting early treatment for patients with acute dyspnea in the emergency setting is a clinical challenge that requires complex decision-making in order to achieve hemodynamic balance, improve functional capacity, and decrease mortality. In the present study, we examined the screening potential of rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating acute heart failure syndromes (AHFS) from primary pulmonary disease in patients with acute dyspnea in the emergency setting. Methods Between March 2011 and March 2012, 90 consecutive patients (45 women, 78.1 ± 9.9 years) admitted to the emergency room of our hospital for acute dyspnea were enrolled. Within 30 minutes of admission, all patients underwent conventional physical examination, rapid ultrasound (lung-cardiac-inferior vena cava [LCI] integrated ultrasound) examination with a hand-held device, routine laboratory tests, measurement of brain natriuretic peptide, and chest X-ray in the emergency room. Results The final diagnosis was acute dyspnea due to AHFS in 53 patients, acute dyspnea due to pulmonary disease despite a history of heart failure in 18 patients, and acute dyspnea due to pulmonary disease in 19 patients. Lung ultrasound alone showed a sensitivity, specificity, negative predictive value, and positive predictive value of 96.2, 54.0, 90.9, and 75.0%, respectively, for differentiating AHFS from pulmonary disease. On the other hand, LCI integrated ultrasound had a sensitivity, specificity, negative predictive value, and positive predictive value of 94.3, 91.9, 91.9, and 94.3%, respectively. Conclusions Our study demonstrated that rapid evaluation by LCI integrated ultrasound is extremely accurate for differentiating acute dyspnea due to AHFS from that caused by primary pulmonary disease in the emergency setting. PMID:23210515

  2. Assessment of flow distribution in the mouse fetal circulation at late gestation by high-frequency Doppler ultrasound.

    PubMed

    Zhou, Yu-Qing; Cahill, Lindsay S; Wong, Michael D; Seed, Mike; Macgowan, Christopher K; Sled, John G

    2014-08-15

    This study used high-frequency ultrasound to evaluate the flow distribution in the mouse fetal circulation at late gestation. We studied 12 fetuses (embryonic day 17.5) from 12 pregnant CD1 mice with 40 MHz ultrasound to assess the flow in 11 vessels based on Doppler measurements of blood velocity and M-mode measurements of diameter. Specifically, the intrahepatic umbilical vein (UVIH), ductus venosus (DV), foramen ovale (FO), ascending aorta (AA), main pulmonary artery (MPA), ductus arteriosus (DA), descending thoracic aorta (DTA), common carotid artery (CCA), inferior vena cava (IVC), and right and left superior vena cavae (RSVC, LSVC) were examined, and anatomically confirmed by micro-CT. The mouse fetal circulatory system was found to be similar to that of the humans in terms of the major circuit and three shunts, but characterized by bilateral superior vena cavae and a single umbilical artery. The combined cardiac output (CCO) was 1.22 ± 0.05 ml/min, with the left ventricle (flow in AA) contributing 47.8 ± 2.3% and the right ventricle (flow in MPA) 52.2 ± 2.3%. Relative to the CCO, the flow percentages were 13.6 ± 1.0% for the UVIH, 10.4 ± 1.1% for the DV, 35.6 ± 2.4% for the DA, 41.9 ± 2.6% for the DTA, 3.8 ± 0.3% for the CCA, 29.5 ± 2.2% for the IVC, 12.7 ± 1.0% for the RSVC, and 9.9 ± 0.9% for the LSVC. The calculated flow percentage was 16.6 ± 3.4% for the pulmonary circulation and 31.2 ± 5.3% for the FO. In conclusion, the flow in mouse fetal circulation can be comprehensively evaluated with ultrasound. The baseline data of the flow distribution in normal mouse fetus serve as the reference range for future studies. Copyright © 2014 the American Physiological Society.

  3. Magnetic ring anastomosis of suprahepatic vena cava: novel technique for liver transplantation in rat.

    PubMed

    Shi, Yuan; Zhang, Wei; Deng, Yong-lin; Zhang, Ya-min; Zhang, Quan-sheng; Zhang, Wei-ye; Zheng, Hong; Pan, Cheng; Shen, Zhong-Yang

    2015-01-01

    To improve the technique of suprahepatic vena cava (SHVC) reconstruction in rat OLT, novel magnetic rings were designed and manufactured to facilitate reconstruction of SHVC and shorten the anhepatic time. One-hundred and twenty adult male Wistar rats were randomly divided into two groups: rings group (n = 30), using magnetic rings for SHVC reconstruction; suture group (n = 30), 7/0 prolene suture was used for SHVC running anastomosis as control. Cuff techniques were used for portal vein and infrahepatic vena cava reconstruction as Kamada and Calne described. The bile duct was reconnected with a stent. The hepatic re-arterialization was omitted. In the rings group, the SHVC reconstruction took 0.91 ± 0.24 (mean ± SD) min; the anhepatic phase and the recipient operation time were 5.63 ± 0.65 min and 36.02 ± 8.02 min, respectively. In suture group, the anastomotic time of SHVC was 10.40 ± 2.11 min; the anhepatic phase and the recipient operation time were 17.76 ± 2.51 and 49.38 ± 12.06 min, respectively, and there was statistically significant difference between the two groups. The ALT levels reached peak at 24 h post-OLT (186.2 ± 32.5 IU/l) and restored to normal level at 96 h gradually. In the rings group, 29 of 30 rats survived at day 7 and 28 of 30 rats survived at day 30. In contrast, only 25 of 30 recipients in suture group remained alive at day 7 and 22 of 30 remained alive at day 30 (P < 0.05). Better anastomotic healing was founded in rings group by pathology and scanning electron microscope. The magnetic rings technique provides a novel, simple method for SHVC reconstruction of OLT in rat. It significantly shortens anhepatic phase, while the success rate of the operation is satisfactory. © 2014 Steunstichting ESOT.

  4. Ultrasound measurement of inferior vena cava diameters by emergency department nurses.

    PubMed

    De Lorenzo, Robert A; Holbrook-Emmons, Victoria L

    2014-01-01

    Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.

  5. Hematoma Shape, Hematoma Size, Glasgow Coma Scale Score and ICH Score: Which Predicts the 30-Day Mortality Better for Intracerebral Hematoma?

    PubMed Central

    Wang, Chih-Wei; Liu, Yi-Jui; Lee, Yi-Hsiung; Hueng, Dueng-Yuan; Fan, Hueng-Chuen; Yang, Fu-Chi; Hsueh, Chun-Jen; Kao, Hung-Wen; Juan, Chun-Jung; Hsu, Hsian-He

    2014-01-01

    Purpose To investigate the performance of hematoma shape, hematoma size, Glasgow coma scale (GCS) score, and intracerebral hematoma (ICH) score in predicting the 30-day mortality for ICH patients. To examine the influence of the estimation error of hematoma size on the prediction of 30-day mortality. Materials and Methods This retrospective study, approved by a local institutional review board with written informed consent waived, recruited 106 patients diagnosed as ICH by non-enhanced computed tomography study. The hemorrhagic shape, hematoma size measured by computer-assisted volumetric analysis (CAVA) and estimated by ABC/2 formula, ICH score and GCS score was examined. The predicting performance of 30-day mortality of the aforementioned variables was evaluated. Statistical analysis was performed using Kolmogorov-Smirnov tests, paired t test, nonparametric test, linear regression analysis, and binary logistic regression. The receiver operating characteristics curves were plotted and areas under curve (AUC) were calculated for 30-day mortality. A P value less than 0.05 was considered as statistically significant. Results The overall 30-day mortality rate was 15.1% of ICH patients. The hematoma shape, hematoma size, ICH score, and GCS score all significantly predict the 30-day mortality for ICH patients, with an AUC of 0.692 (P = 0.0018), 0.715 (P = 0.0008) (by ABC/2) to 0.738 (P = 0.0002) (by CAVA), 0.877 (P<0.0001) (by ABC/2) to 0.882 (P<0.0001) (by CAVA), and 0.912 (P<0.0001), respectively. Conclusion Our study shows that hematoma shape, hematoma size, ICH scores and GCS score all significantly predict the 30-day mortality in an increasing order of AUC. The effect of overestimation of hematoma size by ABC/2 formula in predicting the 30-day mortality could be remedied by using ICH score. PMID:25029592

  6. Outcomes following the Kawashima procedure for single-ventricle palliation in left atrial isomerism.

    PubMed

    Vollebregt, Anne; Pushparajah, Kuberan; Rizvi, Maleeha; Hoschtitzky, Andreas; Anderson, David; Austin, Conal; Tibby, Shane M; Simpson, John

    2012-03-01

    Patients with left atrial isomerism and interrupted inferior vena cava palliated with a superior cavopulmonary connection or Kawashima procedure (KP) have a high incidence of developing pulmonary arteriovenous malformations. The necessity for hepatic vein redirection (HVR) and its timing remains a controversy. We aimed to assess the clinical outcome of patients with left atrial isomerism following a KP. The main end points were death, requirement for HVR and the impact of HVR on oxygen saturation. Retrospective review of 21 patients with a diagnosis of left atrial isomerism, interruption of the inferior vena cava and single-ventricle physiology managed with a KP at a single centre between January 1990 and March 2010. Twenty-one patients had a KP, with 12 subsequently undergoing HVR. There was relatively a constant monthly decrement in the proportion of patients who were free from death or HVR up until 60 months following the KP, with a dramatic increase in the hazard after this time. The Cox proportional hazards regression model demonstrated a reduced early risk for HVR or death in patients who underwent pulmonary artery banding versus arterial shunt as the primary procedure (hazard ratio: 0.10; P = 0.01), and an increased risk with bilateral superior vena cavas (SVCs) (hazard ratio: 3.4; P = 0.04) and age at KP (hazard ratio: 1.02 per month increase in age at KP; P = 0.02). HVR mortality was relatively high with 3 of 12 patients dying in the early postoperative period with profound cyanosis. The timing of HVR after the KP did not influence the postoperative rate of increase in oxygen saturation. These findings confirm that the majority of patients who undergo a KP will require HVR. Patients who are older at the time of the KP or having an initial arterial shunt or bilateral SVCs are at higher risk of HVR or death. The relatively high mortality at HVR was characterized by severe postoperative cyanosis.

  7. Impact of Physician Education and a Dedicated Inferior Vena Cava Filter Tracking System on Inferior Vena Cava Filter Use and Retrieval Rates Across a Large US Health Care Region.

    PubMed

    Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir

    2016-05-01

    To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  8. A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation

    PubMed Central

    Sarach, Janine; Zschokke, Irin; Melcher, Gian A.

    2015-01-01

    Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training. PMID:26703924

  9. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis.

    PubMed

    Liu, Ning; Wang, Zhen; Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18-45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis.

  10. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis

    PubMed Central

    Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18–45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis. PMID:27893792

  11. Model of complete separation of the hepatic veins from the systemic venous system.

    PubMed

    Brizard, C P; Goussef, N; Chachques, J C; Carpentier, A F

    2000-12-01

    In patients undergoing a Fontan operation, partial diversion of the hepatic veins to the pulmonary venous atrium has been tried with various techniques. They failed because of the development of intrahepatic collaterals leading to an unacceptable right-to-left shunting. We postulate that to avoid the formation of intrahepatic collaterals, the totality of the liver has to be drained into the same pressure compartment. We have designed a model of cavopulmonary anastomosis in which a prosthetic conduit reproduces an azygos continuation, associated with the diversion of the totality of the hepatic venous return. This article reports on the early hemodynamics and the fate of the separation of the two venous compartments in long-term survivors. Eighteen goats were operated on; the pulmonary artery and hepatic vein pressures were recorded. During month 2, an opacification of the inferior vena cava and the cavopulmonary connection was performed. Between months 6 and 14, another opacification was performed, together with pressure recording at both ends of the conduit. Postoperatively the pulmonary artery pressure was pulsatile with a mean of 10 mm Hg and the hepatic vein pressure was 0 mm Hg. The first angiogram showed patent tubes with fast progression of the contrast. Throughout the inferior vena cava injection, there was no opacification of the portal or hepatic veins. The late study showed a narrowed conduit in all animals. During the injection, a collateral was injected, feeding into the inferior mesenteric vein. No collateral circulation could be seen draining directly into the liver. The median gradient between the two ends of the conduit was 11 mm Hg. The isolation of the entire hepatic venous drainage is feasible and efficient for the separation of two pressure compartments. No intrahepatic collaterals are observed with this model at short- or long-term follow-up. The separation of the hepatic venous drainage should persist without collateral circulation as long as the inferior vena cava pressure stays at the levels observed in Fontan circulation.

  12. Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.

    The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less

  13. Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.

    PubMed

    Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R

    2018-05-03

    Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.

  14. Surgical resection of recurrent extrahepatic hepatocellular carcinoma with tumor thrombus extending into the right atrium under cardiopulmonary bypass: a case report and review of the literature.

    PubMed

    Ohta, Mineto; Nakanishi, Chikashi; Kawagishi, Naoki; Hara, Yasuyuki; Maida, Kai; Kashiwadate, Toshiaki; Miyazawa, Koji; Yoshida, Satoru; Miyagi, Shigehito; Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsuda, Yasushi; Okada, Yoshinori; Saiki, Yoshikatsu; Ohuchi, Noriaki

    2016-12-01

    Recurrent hepatocellular carcinoma accompanied by a right atrial tumor thrombus is rare. No standard treatment modality has been established. Surgical treatment may be the only curative treatment; however, surgery has been considered high risk. We herein describe a patient who underwent resection of a recurrent right atrial tumor thrombus under normothermic cardiopulmonary bypass on a beating heart. A 60-year-old man underwent a right hepatectomy for hepatocellular carcinoma with diaphragm invasion. During the preoperative cardiac screening, he was diagnosed with an old myocardial infarction with triple-vessel coronary disease. Percutaneous coronary intervention was performed for the left anterior descending artery and left circumflex coronary artery. High-grade stenosis remained in his right coronary artery. Nine months later, computed tomography showed recurrent hepatocellular carcinoma in the diaphragm and a tumor thrombus extending from the suprahepatic inferior vena cava into the right atrium. Surgical resection of the recurrent tumor was performed through a right subcostal incision with xiphoid extension and median sternotomy. The recurrent tumor was incised with the diaphragm and pericardium. Intraoperative ultrasonography revealed that the tumor thrombus was free from right atrium wall invasion and that the right atrium could be clamped just proximal to the tumor thrombus. The right atrium, infrahepatic vena cava, left and middle hepatic veins, and hepatoduodenal ligament were encircled. Cardiopulmonary bypass was performed to prevent ischemic heart disease caused by intraoperative hypotension. Total hepatic vascular exclusion was then performed under normothermic cardiopulmonary bypass on heart beating. The inferior vena cava wall was incised. The tumor thrombus with the diaphragmatic recurrent tumor was resected en bloc. The patient had a favorable clinical course without any complications. The recurrent hepatocellular carcinoma in the diaphragm and the right atrial tumor thrombus were safely resected using normothermic cardiopulmonary bypass on heart beating.

  15. A 1400 km geochemical transect along the Central American Arc: Summary of mafic Holocene volcanism from Guatemala to Panama

    NASA Astrophysics Data System (ADS)

    Geldmacher, J.; Hoernle, K.; Gill, J. B.; Hauff, F.; Heydolph, K.

    2016-12-01

    It is generally accepted that subducted oceanic crust and sediments contribute to the composition of arc magmas. Systematic variations of input parameters (including age, subduction angle, and chemical composition of the subducting material) make the Central American Volcanic Arc (CAVA), which extends from Guatemala in the northwest through El Salvador, Honduras, Nicaragua, Costa Rica and Panama to the southeast, a prime study object. We present a comprehensive (major and trace element and Sr-Nd-Pb-Hf isotope data) and consistent (all data generated in the same labs using the same methods and data reduction procedures) compilation of published and unpublished Holocene mafic volcanic rocks sampled along the entire arc. New data include Sr and, for the first time, Hf isotope data from the entire CAVA as well as major and trace element data for 43 samples from southern Nicaragua and central Costa Rica from which only isotopic compositions were previously published. The combined elemental and isotopic data confirm the influence of distinct subduction components on the composition of CAVA magmas. Along-arc geochemical variations (especially delta 208Pb/204Pb) of volcanic front magmas in Costa Rica and Panama have been explained by the different compositions of seamounts/ridges of the isotopically zoned Galápagos hotspot track that covers the subducting Cocos Plate in this sector of the arc (Hoernle et al. 2008, Nature 451). Our new data confirm this relationship with arc lavas from Costa Rica having higher 87Sr/86Sr ratios than those from western Panama reflecting a similar spatial-compositional distinction in the subducting hotspot track beneath them. In contrast, 176Hf/177Hf shows no comparable variations in this sector of the arc, indicating that the Hf is primarily derived from the mantle wedge rather than the subducting slab. Although small degree hydrous melts are believed to fertilize the mantle wedge beneath Costa Rica, residual zircon may hold back the Hf.

  16. The caudate lobe of the liver: implications of embryology and anatomy for surgery.

    PubMed

    Abdalla, Eddie K; Vauthey, Jean-Nicolas; Couinaud, Claude

    2002-10-01

    The anatomy of the caudate lobe has technical and possibly oncologic implications for surgeons. The complex anatomy of the lobe is clarified by embryologic and anatomic analysis. This posterior sector is embryonically and anatomically independent of the right and left liver and the main portal fissure. The caudate lobe represents the only part of the liver that is in contact with the vena cava, except at the entrance of the main hepatic veins into the vena cava, and provides an anastomosis between the hepatic veins and vena cava. The entire caudate lobe is a single anatomic segment that is defined by the presence of portal venous and hepatic arterial branches, which supply the lobe, draining biliary ducts, and hepatic veins. Because no separate veins, arteries, or ducts can be defined for the right paracaval portion of the posterior liver and because pedicles cross the proposed division between the right and left caudate, the concept of segment IX is abandoned. The significance of caudate anatomy is reflected in the increase in the frequency and safety of major hepatic resection for primary and metastatic tumors in the liver. Right hepatic lobectomy routinely involves resection of the right portion of the caudate lobe (C. Couinaud, unpublished data, 1999). In the case of hilar bile duct cancer, which may extend into the dorsal ducts (especially the right lateral duct), partial or total caudate lobectomy is often necessary for complete extirpation of the tumor. Isolated caudate lobectomy can be performed for hepatocellular carcinoma that arises in the caudate lobe or for other tumors that arise in the lobe. The caudate lobe can be resected as part of the donor liver in preparation for a living related donor transplantation. Knowledge of the surgical anatomy of the caudate lobe is an essential part of the repertoire for surgeons who perform liver transplants or treat hepatobiliary cancer.

  17. Angiotensin‐II receptor 1 antagonist fetopathy – risk assessment, critical time period and vena cava thrombosis as a possible new feature

    PubMed Central

    Oppermann, Marc; Padberg, Stephanie; Kayser, Angela; Weber‐Schoendorfer, Corinna; Schaefer, Christof

    2013-01-01

    Aims Angiotensin‐II receptor 1 antagonists (AT1‐antagonists) may cause severe and even lethal fetopathy in late pregnancy. However, exposure still occurs in spite of warnings in package leaflets. This study aimed to assess the risk of fetopathy, the sensitive time window, and possible new symptoms in prospective as well as retrospective cases with AT1‐antagonist treatment during the second or third trimester of pregnancy. Methods Patients were enrolled by the Berlin Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy between 1999 and 2011 through risk consultation. Symptoms defined as indicative of AT1‐antagonist fetopathy were: oligo‐/anhydramnios, renal insufficiency, lung hypoplasia, joint contractures, skull hypoplasia and fetal/neonatal death. Results In 5/29 (17%) prospectively enrolled cases with AT1‐antagonist exposure beyond the first trimester oligo‐/anhydramnios was diagnosed. Two infants showed additional symptoms of fetopathy. The risk is more than 30% if treatment continues beyond the 20th week of pregnancy. Oligo‐/anhydramnios was reversible after AT1‐antagonist withdrawal. Among 16 retrospective case reports, three infants presented with a thrombosis of the inferior vena cava in the vicinity of the renal veins. Four out of 13 live births did not survive. Conclusions Our survey suggests that the risk increases with duration of AT1‐antagonist treatment into late pregnancy and oligo‐/anhydramnios may be reversible after AT1‐antagonist discontinuation. Thrombosis of inferior vena cava may be a new feature of AT1‐antagonist fetopathy. AT1‐antagonist medication during pregnancy constitutes a considerable risk and must be discontinued immediately. In case of indicative diagnostic findings in either the fetus or newborn, previous maternal AT1‐antagonist exposure should be considered. PMID:22816796

  18. Endovascular stent-based revascularization of malignant superior vena cava syndrome with concomitant implantation of a port device using a dual venous approach.

    PubMed

    Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P

    2018-06-01

    The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.

  19. Photochemical model evaluation of 2013 California wild fire air quality impacts using surface, aircraft, and satellite data.

    PubMed

    Baker, K R; Woody, M C; Valin, L; Szykman, J; Yates, E L; Iraci, L T; Choi, H D; Soja, A J; Koplitz, S N; Zhou, L; Campuzano-Jost, Pedro; Jimenez, Jose L; Hair, J W

    2018-10-01

    The Rim Fire was one of the largest wildfires in California history, burning over 250,000 acres during August and September 2013 affecting air quality locally and regionally in the western U.S. Routine surface monitors, remotely sensed data, and aircraft based measurements were used to assess how well the Community Multiscale Air Quality (CMAQ) photochemical grid model applied at 4 and 12 km resolution represented regional plume transport and chemical evolution during this extreme wildland fire episode. Impacts were generally similar at both grid resolutions although notable differences were seen in some secondary pollutants (e.g., formaldehyde and peroxyacyl nitrate) near the Rim fire. The modeling system does well at capturing near-fire to regional scale smoke plume transport compared to remotely sensed aerosol optical depth (AOD) and aircraft transect measurements. Plume rise for the Rim fire was well characterized as the modeled plume top was consistent with remotely sensed data and the altitude of aircraft measurements, which were typically made at the top edge of the plume. Aircraft-based lidar suggests O 3 downwind in the Rim fire plume was vertically stratified and tended to be higher at the plume top, while CMAQ estimated a more uniformly mixed column of O 3 . Predicted wildfire ozone (O 3 ) was overestimated both at the plume top and at nearby rural and urban surface monitors. Photolysis rates were well characterized by the model compared with aircraft measurements meaning aerosol attenuation was reasonably estimated and unlikely contributing to O 3 overestimates at the top of the plume. Organic carbon was underestimated close to the Rim fire compared to aircraft data, but was consistent with nearby surface measurements. Periods of elevated surface PM 2.5 at rural monitors near the Rim fire were not usually coincident with elevated O 3 . Published by Elsevier B.V.

  20. Systematic review and meta-analysis of persistent left superior vena cava on prenatal ultrasound: associated anomalies, diagnostic accuracy and postnatal outcome.

    PubMed

    Gustapane, S; Leombroni, M; Khalil, A; Giacci, F; Marrone, L; Bascietto, F; Rizzo, G; Acharya, G; Liberati, M; D'Antonio, F

    2016-12-01

    To quantify the prevalence of chromosomal anomalies in fetuses with persistent left superior vena cava (PLSVC), assess the strength of the association between PLSVC and coarctation of the aorta and ascertain the diagnostic accuracy of antenatal ultrasound in correctly identifying isolated cases of PLSVC. MEDLINE, EMBASE, CINHAL and the Cochrane databases were searched from the year 2000 onwards using combinations of keywords 'left superior vena cava' and 'outcome'. Two authors reviewed all abstracts independently. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale for cohort studies. The rates of the following outcomes were analyzed: chromosomal abnormalities; associated intracardiac anomalies (ICAs) and extracardiac anomalies (ECAs) diagnosed prenatally; additional ICAs and ECAs detected only at postnatal imaging or clinical evaluation but missed at prenatal imaging; and association of PLSVC and coarctation of the aorta. Meta-analyses of proportions were used to combine data. In total, 2708 articles were identified and 13 (n = 501) were included in the systematic review. Associated ICAs and ECAs were detected at the prenatal ultrasound examination or at a follow-up assessment in 60.7% (95% CI, 44.2-75.9%) and 37.8% (95% CI, 31.0-44.8%) of cases, respectively. Chromosomal anomalies occurred in 12.5% (95% CI, 9.0-16.4%) of cases in the overall population of fetuses with PLSVC and in 7.0% (95% CI, 2.7-13.0%) of isolated cases. Additional ICAs and ECAs were detected only after birth and missed at ultrasound in 2.4% (95% CI, 0.5-5.8%) and 6.7% (95% CI, 2.2-13.2%) of cases, respectively. Coarctation of the aorta was associated with isolated PLSVC in 21.3% (95% CI, 13.6-30.3%) of cases. PLSVC is commonly associated with ICAs, ECAs and chromosomal anomalies. Fetuses with isolated PLSVC should be followed up throughout pregnancy in order to rule out coarctation of the aorta. As most of the data in this review were derived from high-risk pregnancies, the rate of associated abnormalities is likely to be higher than that in the general population of fetuses with PLSVC, for which more data are needed. Revisión sistemática y metaanálisis de la persistencia de la vena cava superior izquierda en la ecografía prenatal: anomalías asociadas, precisión del diagnóstico y resultado postnatal RESUMEN OBJETIVOS: Cuantificar la prevalencia de anomalías cromosómicas en fetos con vena cava superior izquierda persistente (VCSIP), evaluar la solidez de la asociación entre la VCSIP y la coartación aórtica, y determinar la precisión del diagnóstico de la ecografía prenatal como método para identificar correctamente casos aislados de VCSIP. MÉTODOS: Se buscó en las bases de datos de MEDLINE, EMBASE, CINHAL y Cochrane artículos publicados desde el año 2000 en adelante, usando combinaciones de las palabras clave "vena cava superior izquierda" y "resultado". Dos de los autores revisaron de forma independiente todos los resúmenes encontrados. La evaluación de calidad de los estudios incluidos se realizó mediante la escala Newcastle-Ottawa para estudios de cohortes. Se analizaron las tasas de los siguientes resultados: anomalías cromosómicas; anomalías intracardíacas (AIC) y anomalías extracardíacas (AEC) asociadas diagnosticadas prenatalmente; AIC y AEC adicionales detectadas sólo en ecografías postnatales o mediante evaluación clínica, pero no observadas en ecografías prenatales; y la asociación entre la VCSIP y la coartación aórtica. Se utilizó un meta-análisis de proporciones para combinar los datos. En total, se identificaron 2708 artículos y se incluyeron 13 (n = 501) en la revisión sistemática. En la ecografía prenatal o en una revisión de seguimiento se detectaron AIC y AEC asociadas en el 60,7% (IC 95%, 44,2-75,9%) y el 37,8% (IC 95%, 31,0-44,8%) de los casos, respectivamente. Se produjeron anomalías cromosómicas en el 12,5% (IC 95%, 9,0-16,4%) de los casos en la población general de fetos con VCSIP y en el 7,0% (IC 95%, 2,7-13,0%) de casos aislados. Las AIC y AEC adicionales sólo se detectaron después del nacimiento y en el 6,7% (IC 95%, 2,2-13,2%) de los casos, respectivamente. La coartación aórtica se encontró asociada con la VCSIP aislada en un 21,3% (IC 95%, 13,6-30,3%) de los casos. La VCSIP está comúnmente asociada a AIC, AEC y anomalías cromosómicas. Los fetos con VCSIP aislada deben ser objeto de seguimiento durante todo el embarazo, con el fin de descartar la coartación aórtica. Como la mayoría de los datos de esta revisión proceden de embarazos de alto riesgo, es probable que la tasa de anomalías asociadas sea más alta que la de la población general de fetos con VCSIP, por lo que se necesitan más datos. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  1. RNA-Seq identifies SNPs associated with muscle yield and quality in rainbow trout

    USDA-ARS?s Scientific Manuscript database

    Rainbow trout (Oncorhynchus mykiss) is one of the top five sport fish species in North America and the second most widely cultivated fish species for food. Quality attributes of fish flesh are important determinants of profitability for the food fish aquaculture industry. Single nucleotide polymorph...

  2. Highlights from the Coordinating Research Council’s 2016 Air Quality Research Needs Workshop: Top 11 ResearchNeeds

    EPA Science Inventory

    The Coordinating Research Council (CRC) conducted an Air Quality Research Needs Workshop on February 9-10, 2016 at the Georgia Institute of Technology, in Atlanta, GA. The workshop brought together researchers from academia, government, and industry to brainstorm and prioritize ...

  3. Classroom Quality and Student Behavior Trajectories in Elementary School

    ERIC Educational Resources Information Center

    Griggs, Marissa Swaim; Mikami, Amori Yee; Rimm-Kaufman, Sara E.

    2016-01-01

    Student behavioral concerns are a top priority for school psychologists. This project took an ecological systems perspective by examining the contribution of students' initial externalizing and internalizing behaviors and the quality of their classroom environments to their behavioral outcomes across one school year. Participants included 322…

  4. ASSESSING WATER QUALITY CHANGES IN THE LAKES OF THE NORTHEASTERN UNITED STATES USING SEDIMENT DIATOMS

    EPA Science Inventory

    Diatom assemblages were selected as indicators of lake condition and to assess historical lake water quality changes in 257 lakes in the northeastern United States. The "top" (surface sediments, present-day) and "bottom" (generally from >30 cm deep, representing historical condit...

  5. Indoor Air Quality Basics for Schools.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Radiation and Indoor Air.

    This fact sheet details important information on Indoor Air Quality (IAQ) in school buildings, problems associated with IAQ, and various prevention and problem-solving strategies. Most people spend 90 percent of their time indoors, therefore the Environmental Protection Agency ranks IAQ in the top four environmental risks to the public. The…

  6. Top 10 Reasons for Quality Physical Education

    ERIC Educational Resources Information Center

    Le Masurier, Guy; Corbin, Charles B.

    2006-01-01

    Substantial scientific evidence supports the role of physical activity in disease prevention and healthy lifestyle promotion, and quality physical education represents our best opportunity to provide all children with experiences that promote physical activity now and for a lifetime. The purpose of this article is to document the need for quality…

  7. FY 2002 Customer Satisfaction & Top 200 Users Survey Composite Report

    DTIC Science & Technology

    2002-11-01

    Federal Government Benchmark 68.6% 71.1% DTIC Excels by +8.4 +11 *ACSI is the official service quality benchmark for the...care. § The American Customer Satisfaction Index (ACSI), the official service quality benchmark for the Federal Government, is currently 71.1%; DTIC...ACSI is the official service quality benchmark for the Federal GovernmentFig 1FY 20020Comparison of Customer Satisfaction (Customer Care

  8. Summary of strategies for planning Productivity Improvement and Quality Enhancement (PIQE)

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The Summary of NASA Strategies for Productivity Improvement and Quality Enhancement respond to NASA's eighth top goal: Establish NASA as a leader in the development and application of advanced technology and management practices which contribute to significant increases in both Agency and national productivity. The Strategies provide the framework for development of the agency-wide Productivity Improvement and Quality Enhancement (PIQE) Plans.

  9. "Top Performing" US Hospitals and the Health Status of Counties they Serve.

    PubMed

    Maraccini, Amber M; Yang, Wei; Slonim, Anthony D

    2018-06-01

    This study (a) examined the relationships between "top performing" US hospitals and the health status of counties they serve and (b) compared the health status of "top performing" US hospital counties versus that of remaining US counties. Statistical analyses considered US News and World Report Honor Roll ranking data, as a measure of hospital performance, and County Health Rankings (CHR) data, as a measure of county health status. "Top performing" hospital Honor Roll scores were correlated with measures of Clinical Care (p < 0.001). Counties with "top performing" US hospitals presented greater health status with regard to All Health Outcomes (p < 0.001), Length of Life (p < 0.001), Quality of Life (p < 0.001), All Health Factors (p < 0.001), Health Behaviors (p < 0.001), and Clinical Care (p < 0.001), than compared to remaining US counties. Hospital impact on county health status remains primarily recognized in clinical care and not in overall health. Also, counties that contain a "top performing" US hospital tend to present lower health risks to their citizens than compared to other US counties.

  10. Administrators' and Teachers' Perceptions of Bullying and Bullying Policies in Middle Schools in Three South Carolina School Districts

    ERIC Educational Resources Information Center

    Jordon, Kelly J.

    2014-01-01

    Our nation's schools are faced with numerous critical challenges and problems; meeting federal and state mandates, state standards, elevating academic achievement, increasing parental involvement, and violence in the schools (Gould, 2011; Kowalski & Cangemi, 2011; Simpson, LaCava, & Graner, 2004). Violence in many U.S. schools continues to…

  11. Side-to-side cavo-cavostomy: a useful aid in "complicated" piggy-back liver transplantation.

    PubMed

    Lerut, J; Gertsch, P

    1993-01-01

    Piggy-back liver transplantation is a useful technical variant of orthotopic liver transplantation. Its success can, however, be compromised by severe stenosis or obstruction of the recipient's inferior vena cava at the level of the anastomosis. A technique is described--side-to-side cavocavostomy--to resolve this difficult intraoperative situation.

  12. Abnormal location of umbilical venous catheter due to Scimitar syndrome

    PubMed Central

    Mart, Christopher R; Van Dorn, Charlotte S

    2014-01-01

    Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705

  13. Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound

    DTIC Science & Technology

    2016-10-01

    with this study, Dr. Doucet has produced “Protocol Video USA-IVC Study (Version 5)” that is posted on youtube : https://youtu.be/54-Z6fiJpPY This video... youtube : https://youtu.be/54-Z6fiJpPY This video contains study design, procedures, inclusion/exclusion criteria and a demonstration to train clinical

  14. Two cases of retroperitoneal haematoma caused by interaction between antibiotics and warfarin

    PubMed Central

    Phillips, S; Barr, A; Wilson, E; Rockall, T A; Stebbing, J F

    2006-01-01

    Several commonly prescribed antibiotics are known to interact with warfarin, increasing its anticoagulant effect by different mechanisms. Retroperitoneal bleeding with consequent haematoma is recognised as a complication of over‐anticoagulation. Consequences, which are potentially fatal, include hypovolaemic shock and compression of retroperitoneal structures such as the ureter and inferior vena cava. PMID:16373793

  15. Search Engine Ranking, Quality, and Content of Web Pages That Are Critical Versus Noncritical of Human Papillomavirus Vaccine.

    PubMed

    Fu, Linda Y; Zook, Kathleen; Spoehr-Labutta, Zachary; Hu, Pamela; Joseph, Jill G

    2016-01-01

    Online information can influence attitudes toward vaccination. The aim of the present study was to provide a systematic evaluation of the search engine ranking, quality, and content of Web pages that are critical versus noncritical of human papillomavirus (HPV) vaccination. We identified HPV vaccine-related Web pages with the Google search engine by entering 20 terms. We then assessed each Web page for critical versus noncritical bias and for the following quality indicators: authorship disclosure, source disclosure, attribution of at least one reference, currency, exclusion of testimonial accounts, and readability level less than ninth grade. We also determined Web page comprehensiveness in terms of mention of 14 HPV vaccine-relevant topics. Twenty searches yielded 116 unique Web pages. HPV vaccine-critical Web pages comprised roughly a third of the top, top 5- and top 10-ranking Web pages. The prevalence of HPV vaccine-critical Web pages was higher for queries that included term modifiers in addition to root terms. Compared with noncritical Web pages, Web pages critical of HPV vaccine overall had a lower quality score than those with a noncritical bias (p < .01) and covered fewer important HPV-related topics (p < .001). Critical Web pages required viewers to have higher reading skills, were less likely to include an author byline, and were more likely to include testimonial accounts. They also were more likely to raise unsubstantiated concerns about vaccination. Web pages critical of HPV vaccine may be frequently returned and highly ranked by search engine queries despite being of lower quality and less comprehensive than noncritical Web pages. Copyright © 2016 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  16. Solar Wind Driven Autoregression Model for Ionospheric Short Term Forecast (SWIF)

    DTIC Science & Technology

    2008-06-01

    for GCAM; previous two months for TSAR). However the quality of the autoscaling software ( ARTIST ) performance determines largely the accuracy of...showing the SWIF synthesis. Figure 17: Athens Digisonde ionograms autoscaled with ARTIST4.0 (top) and with ARTIST4.5 (bottom) during fall quiet...intervals Figure 18: Athens Digisonde ionograms autoscaled with ARTIST4.0 (top) and with ARTIST4.5 (bottom) during summer quiet intervals Figure 19

  17. Dearth by a Thousand Cuts? Accounting for Gender Differences in Top-Ranked Publication Rates in Social Psychology.

    PubMed

    Cikara, Mina; Rudman, Laurie; Fiske, Susan

    2012-01-01

    Publication in the Journal of Personality and Social Psychology , a flagship indicator of scientific prestige, shows dramatic gender disparities. A bibliometric analysis included yoked-control authors matched for Ph.D. prestige and cohort. Though women publish less, at slower annual rates, they are more cited in handbooks and textbooks per JPSP -article-published. No gender differences emerged on variables reflecting differential qualifications. Many factors explain gender discrepancy in productivity. Among top publishers, per-year rate and first authorship especially differ by gender; rate uniquely predicts top-male productivity, whereas career-length uniquely predicts top-female productivity. Among men, across top-publishers and controls, productivity correlates uniquely with editorial negotiating and being married. For women, no personal variables predict productivity. A separate inquiry shows tiny gender differences in acceptance rates per JPSP article submitted; discrimination would be a small-but-plausible contributor, absent independent indicators of manuscript quality. Recent productivity rates mirror earlier gender disparities, suggesting gender gaps will continue.

  18. The eighth NASA total quality management accomplishments report, 1990

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The eighth annual accomplishments report provides numerous examples of quality strategies that have proven effective and efficient in a time when cost reduction is critical. NASA's continuous improvement efforts can provide insight for others to succeed in their own endeavors. The report covers: top management leadership and support, strategic planning, focus on the customer, employee training and recognition, employee empowerment and teamwork, measurement and analysis, and quality assurance.

  19. 78 FR 53991 - Applications for New Awards; Race to the Top-Early Learning Challenge

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-30

    ... gaps for Children with High Needs.\\1\\ This program focuses on improving early learning and development... disadvantaged children in each age group of infants, toddlers, and preschoolers who are enrolled in high-quality... implement an integrated system of high-quality Early Learning and Development Programs and services. \\1...

  20. Top Management Leadership Style and Quality of Care in Nursing Homes

    ERIC Educational Resources Information Center

    Castle, Nicholas G.; Decker, Frederic H.

    2011-01-01

    Purpose: The purpose of this study was to examine the association of Nursing Home Administrator (NHA) leadership style and Director of Nursing (DON) leadership style with quality of care. Design and Methods: Leaders were categorized into 4 groups: consensus managers, consultative autocrats, shareholder managers, or autocrats. This leadership style…

Top